SIO Argo Site:
Pump Diagnostics Page   



Serial= 3125 WMO= 5906774

Return

←PreviousNext→

Cycle 40 GMT 21/11/2023 21:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 32 15.19 500 243 0.24 / 161.33 2 3
2 3 988.32 -1 15.51 0 0 0.00 / 161.33 2 3
3 3 1018.84 1 15.21 1782 27 0.27 / 161.36 2 4
4 7 2004.32 38 14.74 2995 1678 1.95 / 163.04 2 4
5 13 1436.12 18 14.87 2300 616 2.56 / 163.65 2 6
6 13 802.84 18 15.03 1466 397 2.96 / 164.05 2 8
7 13 266.84 18 15.21 716 196 3.16 / 164.24 2 8
8 8 0.28 165 15.24 325 817 3.97 / 165.06 2 10
Average= 4.03 (KJ/cycle)

Cycle 39 GMT 12/11/2023 1:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 15.19 489 238 0.24 / 157.32 2 2
2 3 975.48 -1 15.52 0 0 0.00 / 157.32 2 2
3 3 1017.24 1 15.20 1799 27 0.27 / 157.35 2 4
4 7 2011.92 38 14.74 3012 1687 1.95 / 159.03 2 4
5 13 1394.44 18 14.88 2253 603 2.56 / 159.64 2 6
6 13 862.12 18 15.03 1544 418 2.97 / 160.06 2 7
7 13 270.12 18 15.21 721 197 3.17 / 160.25 2 8
8 8 0.16 165 15.24 332 835 4.01 / 161.09 2 14
Average= 4.03 (KJ/cycle)

Cycle 38 GMT 2/11/2023 6:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 32 15.19 489 238 0.24 / 153.30 2 3
2 3 979.60 -1 15.52 0 0 0.00 / 153.30 2 3
3 3 1018.60 1 15.21 1808 27 0.27 / 153.33 2 4
4 7 2003.32 38 14.75 3020 1693 1.96 / 155.02 2 4
5 13 1372.64 18 14.89 2225 596 2.55 / 155.62 2 6
6 13 886.52 18 15.01 1578 426 2.98 / 156.04 2 8
7 13 294.28 18 15.20 761 208 3.19 / 156.25 2 9
8 8 0.28 165 15.24 331 832 4.02 / 157.08 2 13
Average= 4.03 (KJ/cycle)

Cycle 37 GMT 23/10/2023 11:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 32 15.19 496 241 0.24 / 149.30 2 3
2 3 985.04 -1 15.51 0 0 0.00 / 149.30 2 3
3 3 1017.84 1 15.21 1787 27 0.27 / 149.33 2 3
4 7 2005.04 38 14.74 3018 1690 1.96 / 151.02 2 4
5 13 1349.48 18 14.90 2190 587 2.55 / 151.61 2 6
6 13 895.60 18 15.01 1591 430 2.98 / 152.04 2 8
7 13 282.00 18 15.20 744 204 3.18 / 152.24 2 9
8 8 0.04 165 15.24 327 822 4.00 / 153.06 2 19
Average= 4.03 (KJ/cycle)

Cycle 36 GMT 13/10/2023 16: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 32 15.20 486 236 0.24 / 145.30 2 3
2 3 975.88 -1 15.52 0 0 0.00 / 145.30 2 3
3 3 1025.72 1 15.18 1800 27 0.26 / 145.33 2 5
4 7 2004.36 38 14.73 3019 1690 1.95 / 147.02 2 4
5 13 1391.64 18 14.89 2250 603 2.56 / 147.62 2 6
6 13 857.64 18 15.03 1544 418 2.97 / 148.04 2 8
7 13 266.00 18 15.21 720 197 3.17 / 148.24 2 8
8 8 -0.16 165 15.24 327 822 3.99 / 149.06 2 12
Average= 4.03 (KJ/cycle)

Cycle 35 GMT 3/10/2023 20:50: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 15.20 485 236 0.24 / 141.32 2 3
2 3 981.56 -1 15.53 0 0 0.00 / 141.32 2 3
3 3 1021.36 1 15.20 1807 27 0.26 / 141.34 2 4
4 7 2010.40 38 14.74 3023 1693 1.96 / 143.04 2 6
5 13 1351.32 18 14.90 2200 590 2.55 / 143.63 2 6
6 13 864.28 18 15.01 1558 421 2.97 / 144.05 2 7
7 13 258.56 18 15.22 707 194 3.16 / 144.24 2 8
8 8 0.32 165 15.25 328 825 3.99 / 145.07 2 17
Average= 4.03 (KJ/cycle)

Cycle 34 GMT 24/ 9/2023 1:26:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 32 15.20 485 236 0.24 / 137.34 2 3
2 3 986.56 -1 15.53 0 0 0.00 / 137.34 2 3
3 3 1028.72 1 15.18 1817 28 0.26 / 137.37 2 5
4 7 2007.40 38 14.75 3012 1688 1.95 / 139.06 2 5
5 13 1317.04 18 14.92 2158 580 2.53 / 139.63 2 7
6 13 925.24 18 15.00 1631 440 2.97 / 140.08 2 8
7 13 230.00 18 15.24 668 183 3.15 / 140.26 2 8
8 8 -0.04 165 15.26 326 821 3.98 / 141.08 2 14
Average= 4.03 (KJ/cycle)

Cycle 33 GMT 14/ 9/2023 5:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 32 15.20 493 240 0.24 / 133.39 2 3
2 3 980.44 -1 15.55 0 0 0.00 / 133.39 2 3
3 7 2005.56 38 14.75 3018 1692 1.93 / 135.08 2 5
4 13 1374.68 18 14.90 2232 599 2.53 / 135.68 2 6
5 13 849.32 18 15.04 1535 416 2.95 / 136.09 2 9
6 13 218.24 18 15.24 654 179 3.12 / 136.27 2 8
7 8 0.16 165 15.25 330 830 3.96 / 137.10 2 13
Average= 4.03 (KJ/cycle)

Cycle 32 GMT 4/ 9/2023 10:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.20 500 243 0.24 / 129.41 2 3
2 3 981.92 -1 15.54 0 0 0.00 / 129.41 2 3
3 3 1022.60 1 15.21 1810 28 0.27 / 129.44 2 5
4 7 2005.16 38 14.76 3006 1686 1.96 / 131.13 2 5
5 13 1342.64 18 14.92 2179 585 2.54 / 131.71 2 7
6 13 854.56 18 15.05 1540 417 2.96 / 132.13 2 8
7 13 246.76 18 15.24 693 190 3.15 / 132.32 2 8
8 8 0.20 165 15.26 329 828 3.98 / 133.15 2 14
Average= 4.03 (KJ/cycle)

Cycle 31 GMT 25/ 8/2023 15:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 32 15.23 476 232 0.23 / 125.44 2 3
2 3 978.60 -1 15.55 0 0 0.00 / 125.44 2 3
3 3 1021.32 1 15.19 1820 28 0.26 / 125.47 2 5
4 7 2009.80 38 14.76 3027 1698 1.96 / 127.17 2 4
5 13 1292.08 18 14.93 2117 569 2.53 / 127.74 2 8
6 13 818.64 18 15.06 1488 403 2.93 / 128.14 2 8
7 13 262.92 18 15.22 717 196 3.13 / 128.34 2 9
8 8 0.16 165 15.26 331 833 3.96 / 129.17 2 15
Average= 4.04 (KJ/cycle)

Cycle 30 GMT 15/ 8/2023 19:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 15.22 488 238 0.24 / 121.49 2 3
2 3 982.88 -1 15.54 0 0 0.00 / 121.49 2 3
3 3 1027.36 1 15.20 1817 28 0.27 / 121.52 2 4
4 7 2005.04 38 14.77 3004 1686 1.95 / 123.20 2 6
5 13 1347.68 18 14.92 2194 589 2.54 / 123.79 2 6
6 13 825.52 18 15.05 1504 407 2.95 / 124.20 2 8
7 13 242.28 18 15.24 687 188 3.14 / 124.39 2 8
8 8 1.40 165 15.27 327 824 3.96 / 125.21 2 10
Average= 4.04 (KJ/cycle)

Cycle 29 GMT 6/ 8/2023 0:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 32 15.22 498 243 0.24 / 117.47 2 3
2 3 979.00 -1 15.54 0 0 0.00 / 117.47 2 3
3 7 2010.32 38 14.77 3024 1697 1.94 / 119.17 2 5
4 13 1430.24 18 14.92 2301 618 2.56 / 119.79 2 6
5 13 883.08 18 15.04 1581 428 2.99 / 120.22 2 8
6 13 288.88 18 15.22 756 207 3.19 / 120.42 2 8
7 8 -0.08 165 15.27 328 826 4.02 / 121.25 2 14
Average= 4.04 (KJ/cycle)

Cycle 28 GMT 27/ 7/2023 4:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 32 15.22 486 237 0.24 / 113.54 2 3
2 3 979.96 -1 15.54 0 0 0.00 / 113.54 2 3
3 7 2007.00 38 14.77 3017 1693 1.93 / 115.23 2 4
4 13 1354.64 18 14.92 2196 590 2.52 / 115.82 2 8
5 13 791.72 18 15.07 1456 395 2.91 / 116.21 2 8
6 13 252.84 18 15.24 706 194 3.11 / 116.41 2 8
7 8 0.20 165 15.26 327 823 3.93 / 117.23 2 10
Average= 4.04 (KJ/cycle)

Cycle 27 GMT 17/ 7/2023 9:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 32 15.23 500 244 0.24 / 109.53 2 3
2 3 989.44 -1 15.56 0 0 0.00 / 109.53 2 3
3 3 1020.24 1 15.21 1807 27 0.27 / 109.56 2 5
4 7 2004.24 38 14.77 3015 1692 1.96 / 111.25 2 4
5 13 1423.52 18 14.91 2284 613 2.58 / 111.86 2 6
6 13 842.16 18 15.06 1521 412 2.99 / 112.28 2 9
7 13 253.80 18 15.24 705 193 3.18 / 112.47 2 9
8 8 0.00 165 15.27 329 829 4.01 / 113.30 2 12
Average= 4.05 (KJ/cycle)

Cycle 26 GMT 7/ 7/2023 14: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 15.24 486 237 0.24 / 105.58 2 3
2 3 987.76 -1 15.56 0 0 0.00 / 105.58 2 3
3 3 1018.88 1 15.23 1808 28 0.26 / 105.61 2 4
4 7 2006.48 38 14.78 3019 1696 1.96 / 107.31 2 4
5 13 1310.12 18 14.95 2141 576 2.54 / 107.88 2 6
6 13 792.16 18 15.07 1450 393 2.93 / 108.28 2 9
7 13 244.88 18 15.25 686 188 3.12 / 108.46 2 8
8 8 0.00 165 15.28 327 824 3.94 / 109.29 2 14
Average= 4.05 (KJ/cycle)

Cycle 25 GMT 27/ 6/2023 18:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 32 15.22 488 238 0.24 / 101.63 2 3
2 3 976.76 -1 15.56 0 0 0.00 / 101.63 2 3
3 7 2004.28 38 14.79 3016 1695 1.93 / 103.33 2 4
4 13 1325.12 18 14.95 2168 583 2.52 / 103.91 2 7
5 13 818.80 18 15.08 1493 405 2.92 / 104.32 2 8
6 13 283.24 18 15.24 741 203 3.12 / 104.52 2 8
7 8 0.36 165 15.28 327 824 3.95 / 105.35 2 12
Average= 4.05 (KJ/cycle)

Cycle 24 GMT 17/ 6/2023 23: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 32 15.23 482 235 0.23 / 97.63 2 3
2 3 986.72 -1 15.57 0 0 0.00 / 97.63 2 3
3 3 1018.84 1 15.25 1802 27 0.26 / 97.66 2 4
4 7 2002.80 38 14.78 3017 1694 1.96 / 99.35 2 4
5 13 1339.56 18 14.94 2188 588 2.55 / 99.94 2 7
6 13 854.04 18 15.06 1546 419 2.96 / 100.36 2 7
7 13 285.84 18 15.25 750 206 3.17 / 100.57 2 8
8 8 0.12 165 15.28 330 832 4.00 / 101.40 2 13
Average= 4.06 (KJ/cycle)

Cycle 23 GMT 8/ 6/2023 3:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 15.25 482 235 0.24 / 93.64 2 3
2 3 984.60 -1 15.57 0 0 0.00 / 93.64 2 3
3 3 1016.76 1 15.25 1792 27 0.26 / 93.66 2 4
4 7 2002.40 38 14.79 3012 1693 1.96 / 95.36 2 4
5 13 1382.36 18 14.95 2239 603 2.56 / 95.96 2 7
6 13 840.56 18 15.07 1527 414 2.97 / 96.37 2 8
7 13 250.12 18 15.26 699 192 3.16 / 96.56 2 8
8 8 0.00 165 15.29 329 830 3.99 / 97.39 2 11
Average= 4.06 (KJ/cycle)

Cycle 22 GMT 29/ 5/2023 8:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 32 15.23 487 237 0.24 / 89.66 2 3
2 3 986.20 -1 15.56 0 0 0.00 / 89.66 2 3
3 3 1028.48 1 15.21 1830 28 0.27 / 89.69 2 5
4 7 2002.68 38 14.79 3008 1691 1.96 / 91.38 2 5
5 13 1350.96 18 14.94 2206 593 2.55 / 91.97 2 6
6 13 828.64 18 15.08 1506 409 2.96 / 92.38 2 8
7 13 238.28 18 15.26 682 187 3.15 / 92.57 2 8
8 8 0.04 165 15.29 329 830 3.98 / 93.40 2 13
Average= 4.06 (KJ/cycle)

Cycle 21 GMT 19/ 5/2023 13: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.24 494 241 0.24 / 85.67 2 3
2 7 2010.72 38 14.80 3017 1697 1.94 / 87.36 2 4
3 13 1399.16 18 14.95 2267 610 2.55 / 87.97 2 6
4 13 904.56 18 15.06 1604 435 2.98 / 88.41 2 8
5 13 263.16 18 15.25 711 195 3.18 / 88.60 2 8
6 8 0.00 165 15.28 326 822 4.00 / 89.43 2 12
Average= 4.06 (KJ/cycle)

Cycle 20 GMT 9/ 5/2023 17:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 15.24 491 239 0.24 / 81.56 2 2
2 7 2009.64 39 14.80 3025 1746 1.99 / 83.31 2 5
3 13 1380.92 18 14.95 2240 603 2.59 / 83.91 2 6
4 13 853.76 18 15.07 1539 417 3.01 / 84.33 2 7
5 13 211.48 18 15.29 642 177 3.18 / 84.51 2 7
6 13 24.68 18 15.33 366 101 3.28 / 84.61 2 6
7 8 0.32 165 15.29 325 820 4.10 / 85.43 2 10
Average= 4.07 (KJ/cycle)

Cycle 19 GMT 29/ 4/2023 22:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 15.24 493 240 0.24 / 77.56 2 3
2 3 982.64 -1 15.56 0 0 0.00 / 77.56 2 3
3 3 1021.08 1 15.25 1813 28 0.27 / 77.59 2 4
4 7 2004.32 38 14.81 3026 1703 1.97 / 79.29 2 5
5 13 1349.92 18 14.96 2195 591 2.56 / 79.88 2 7
6 13 820.16 18 15.09 1493 406 2.97 / 80.29 2 7
7 13 272.72 18 15.26 731 201 3.17 / 80.49 2 8
8 8 0.16 165 15.30 330 833 4.00 / 81.32 2 18
Average= 4.07 (KJ/cycle)

Cycle 18 GMT 20/ 4/2023 3: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 32 15.23 501 244 0.24 / 73.48 2 3
2 7 2007.36 38 14.81 3015 1697 1.94 / 75.18 2 4
3 13 1402.52 18 14.95 2257 607 2.55 / 75.79 2 7
4 13 832.16 18 15.09 1506 409 2.96 / 76.20 2 8
5 13 292.76 18 15.26 757 208 3.17 / 76.40 2 8
6 13 16.08 18 15.33 354 98 3.26 / 76.50 2 6
7 8 0.00 165 15.29 325 820 4.08 / 77.32 2 14
Average= 4.07 (KJ/cycle)

Cycle 17 GMT 10/ 4/2023 7:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 31 15.24 487 230 0.23 / 69.41 2 3
2 3 989.00 -1 15.57 0 0 0.00 / 69.41 2 3
3 3 1027.76 1 15.24 1814 28 0.26 / 69.44 2 6
4 7 2003.48 38 14.81 3014 1696 1.95 / 71.14 2 5
5 13 1343.44 18 14.96 2188 589 2.54 / 71.72 2 8
6 13 856.48 18 15.09 1539 418 2.96 / 72.14 2 8
7 13 205.56 18 15.29 631 174 3.13 / 72.32 2 7
8 13 20.48 18 15.33 361 100 3.23 / 72.42 2 6
9 8 0.12 165 15.29 326 822 4.06 / 73.24 2 14
Average= 4.07 (KJ/cycle)

Cycle 16 GMT 31/ 3/2023 12:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 31 15.24 488 231 0.23 / 65.31 2 3
2 3 989.52 -1 15.61 0 0 0.00 / 65.31 2 3
3 7 2008.76 38 14.82 3021 1701 1.93 / 67.01 2 5
4 13 1444.28 18 14.94 2328 626 2.56 / 67.63 2 7
5 13 864.24 18 15.08 1555 422 2.98 / 68.06 2 8
6 13 271.52 18 15.26 731 201 3.18 / 68.26 2 8
7 13 28.80 18 15.32 373 103 3.28 / 68.36 2 7
8 8 -0.04 165 15.29 326 822 4.11 / 69.18 2 13
Average= 4.07 (KJ/cycle)

Cycle 15 GMT 21/ 3/2023 16:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 31 15.24 488 231 0.23 / 61.23 2 3
2 3 990.52 -1 15.57 0 0 0.00 / 61.23 2 3
3 3 1028.36 1 15.24 1828 28 0.26 / 61.26 2 5
4 7 2003.84 38 14.82 3027 1705 1.96 / 62.96 2 5
5 13 1304.64 18 14.97 2149 579 2.54 / 63.54 2 8
6 13 825.84 18 15.09 1506 409 2.95 / 63.95 2 8
7 13 223.88 18 15.28 665 183 3.13 / 64.13 2 9
8 13 24.20 18 15.33 375 103 3.24 / 64.24 2 7
9 8 0.36 165 15.29 332 838 4.08 / 65.08 2 13
Average= 4.07 (KJ/cycle)

Cycle 14 GMT 11/ 3/2023 21:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 31 15.24 494 233 0.23 / 57.11 2 2
2 7 2008.88 39 14.82 3021 1746 1.98 / 58.86 2 5
3 13 1344.72 18 14.97 2204 594 2.57 / 59.45 2 7
4 13 865.68 18 15.08 1558 423 3.00 / 59.87 2 9
5 13 250.08 18 15.27 703 193 3.19 / 60.07 2 9
6 13 16.48 18 15.33 362 100 3.29 / 60.17 2 8
7 8 0.08 165 15.29 330 833 4.12 / 61.00 2 15
Average= 4.07 (KJ/cycle)

Cycle 13 GMT 2/ 3/2023 2: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 31 15.25 486 230 0.23 / 53.05 2 2
2 7 2003.96 38 14.82 3007 1693 1.92 / 54.75 2 4
3 13 1343.20 18 14.97 2183 588 2.51 / 55.33 2 7
4 13 856.44 18 15.09 1546 420 2.93 / 55.75 2 8
5 13 239.84 18 15.28 686 189 3.12 / 55.94 2 9
6 13 17.88 18 15.33 363 100 3.22 / 56.04 2 8
7 8 0.04 165 15.29 331 835 4.06 / 56.88 2 15
Average= 4.06 (KJ/cycle)

Cycle 12 GMT 20/ 2/2023 6:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 31 15.24 500 236 0.24 / 49.01 2 3
2 3 1016.28 1 15.25 1807 28 0.26 / 49.03 2 4
3 7 2004.20 38 14.83 2997 1689 1.95 / 50.72 2 4
4 13 1302.28 18 14.99 2122 573 2.53 / 51.29 2 6
5 13 788.84 18 15.12 1453 395 2.92 / 51.69 2 8
6 13 271.24 18 15.27 731 201 3.12 / 51.89 2 9
7 13 21.80 18 15.33 371 102 3.22 / 51.99 2 8
8 8 -0.08 165 15.29 329 830 4.05 / 52.82 2 14
Average= 4.06 (KJ/cycle)

Cycle 11 GMT 10/ 2/2023 11:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 31 15.25 486 230 0.23 / 44.96 2 2
2 7 2003.88 38 14.83 3016 1700 1.93 / 46.66 2 4
3 13 1303.32 18 14.99 2140 577 2.51 / 47.23 2 7
4 13 828.72 18 15.11 1505 409 2.92 / 47.64 2 8
5 13 233.60 18 15.29 682 188 3.10 / 47.83 2 8
6 13 15.72 18 15.35 363 100 3.20 / 47.93 2 7
7 8 0.00 165 15.30 332 838 4.04 / 48.77 2 13
Average= 4.06 (KJ/cycle)

Cycle 10 GMT 31/ 1/2023 15:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 31 15.25 498 235 0.24 / 40.95 2 3
2 7 2005.04 38 14.84 3014 1700 1.94 / 42.65 2 4
3 13 1329.56 18 14.98 2171 585 2.52 / 43.23 2 7
4 13 767.12 18 15.12 1425 388 2.91 / 43.62 2 8
5 13 192.88 18 15.30 618 170 3.08 / 43.79 2 8
6 13 17.36 18 15.34 365 101 3.18 / 43.89 2 8
7 8 0.12 165 15.30 331 836 4.01 / 44.73 2 15
Average= 4.07 (KJ/cycle)

Cycle 9 GMT 21/ 1/2023 20:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 31 15.27 488 231 0.23 / 36.19 2 2
2 7 2005.40 74 14.72 3004 3272 3.50 / 39.46 2 5
3 13 536.20 18 15.19 1105 302 3.81 / 39.77 2 9
4 13 27.12 18 15.34 378 104 3.91 / 39.87 2 8
5 8 -0.04 165 15.31 333 841 4.75 / 40.71 2 13
Average= 4.07 (KJ/cycle)

Cycle 8 GMT 11/ 1/2023 23:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 15.26 487 230 0.23 / 31.47 2 3
2 7 2003.52 74 14.73 3004 3274 3.50 / 34.74 2 5
3 13 415.28 18 15.24 934 256 3.76 / 35.00 2 9
4 13 30.56 18 15.34 386 107 3.87 / 35.11 2 8
5 8 0.12 165 15.31 338 854 4.72 / 35.96 2 22
Average= 4.00 (KJ/cycle)

Cycle 7 GMT 2/ 1/2023 1:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 31 15.25 491 232 0.23 / 26.74 2 3
2 7 2007.40 74 14.72 3003 3271 3.50 / 30.01 2 5
3 13 502.32 18 15.20 1055 289 3.79 / 30.30 2 9
4 13 21.20 18 15.35 369 102 3.89 / 30.40 2 7
5 8 0.00 165 15.31 331 836 4.73 / 31.24 2 15
Average= 3.90 (KJ/cycle)

Cycle 6 GMT 23/12/2022 4:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 30 15.26 503 230 0.23 / 21.97 2 3
2 3 1048.88 1 15.25 1830 28 0.26 / 22.00 2 5
3 7 2008.56 74 14.73 3009 3280 3.54 / 25.28 2 5
4 13 522.72 18 15.20 1083 296 3.83 / 25.57 2 9
5 13 23.20 18 15.35 371 103 3.94 / 25.68 2 9
6 8 0.00 165 15.30 330 833 4.77 / 26.51 2 14
Average= 3.79 (KJ/cycle)

Cycle 5 GMT 13/12/2022 7:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 29 15.27 486 215 0.22 / 17.25 2 3
2 3 1035.48 1 15.25 1814 28 0.24 / 17.28 2 4
3 7 2003.84 74 14.73 2997 3267 3.51 / 20.55 2 5
4 13 394.36 18 15.25 903 248 3.76 / 20.79 2 8
5 13 50.80 18 15.34 409 113 3.87 / 20.91 2 7
6 8 0.04 165 15.31 330 834 4.70 / 21.74 2 14
Average= 3.62 (KJ/cycle)

Cycle 4 GMT 3/12/2022 10: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 23 15.27 497 175 0.17 / 13.18 2 3
2 10 1029.76 4 15.18 1797 109 0.28 / 13.29 2 3
3 10 1068.28 2 15.18 1855 56 0.34 / 13.35 2 3
4 3 1046.96 1 15.24 1838 28 0.37 / 13.38 2 4
5 7 1507.04 74 14.93 2360 2607 2.98 / 15.98 2 5
6 13 300.84 18 15.28 768 211 3.19 / 16.20 2 8
7 8 0.12 165 15.32 332 839 4.03 / 17.04 2 14
Average= 3.41 (KJ/cycle)

Cycle 3 GMT 2/12/2022 10:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 41 15.24 487 304 0.30 / 9.40 2 3
2 3 633.16 -7 15.63 0 0 0.00 / 9.40 2 3
3 3 762.00 -5 15.64 0 0 0.00 / 9.40 2 3
4 7 1508.56 74 14.94 2359 2608 2.91 / 12.01 2 5
5 13 171.40 18 15.33 580 160 3.07 / 12.17 2 7
6 8 0.12 165 15.32 331 837 3.91 / 13.01 2 14
Average= 3.25 (KJ/cycle)

Cycle 2 GMT 1/12/2022 10:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 31 15.29 488 231 0.23 / 5.15 2 3
2 10 1099.36 5 15.17 1897 144 0.38 / 5.29 2 3
3 10 1138.64 2 15.18 1954 59 0.43 / 5.35 2 3
4 3 1138.36 4 15.18 1988 121 0.56 / 5.47 2 4
5 3 1023.76 1 15.29 1808 28 0.58 / 5.50 2 4
6 7 1507.56 74 14.92 2356 2601 3.18 / 8.10 2 5
7 13 172.20 18 15.31 583 161 3.34 / 8.26 2 8
8 8 0.08 165 15.31 332 839 4.18 / 9.10 2 17
Average= 3.03 (KJ/cycle)

Cycle 1 GMT 30/11/2022 11:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 15.44 455 183 0.18 / 2.11 2 2
2 10 1003.92 3 15.26 1769 81 0.26 / 2.19 2 2
3 7 1005.28 74 15.09 1692 1889 2.15 / 4.08 2 7
4 8 -0.08 165 15.35 331 838 2.99 / 4.92 2 16
Average= 2.46 (KJ/cycle)

Cycle 0 GMT 30/11/2022 1: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.40 26 15.60 520 211 0.21 / 0.21 2 2
2 7 168.68 74 15.56 535 616 0.83 / 0.83 2 2
3 8 0.28 240 15.52 295 1099 1.93 / 1.93 2 11
Average= 1.93 (KJ/cycle)