SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 30 | 15.01 | 492 | 222 | 0.22 / 311.92 | 2 | 6 |
2 | 7 | 2005.36 | 38 | 14.67 | 3002 | 1673 | 1.90 / 313.59 | 2 | 7 |
3 | 13 | 1329.56 | 18 | 14.77 | 2151 | 572 | 2.47 / 314.16 | 2 | 9 |
4 | 13 | 765.44 | 18 | 14.88 | 1402 | 376 | 2.84 / 314.54 | 2 | 11 |
5 | 13 | 207.60 | 18 | 15.04 | 635 | 172 | 3.01 / 314.71 | 2 | 11 |
6 | 8 | 0.48 | 165 | 15.06 | 327 | 813 | 3.83 / 315.52 | 2 | 15 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 30 | 15.01 | 484 | 218 | 0.22 / 308.04 | 2 | 5 |
2 | 7 | 2003.20 | 39 | 14.66 | 2996 | 1713 | 1.93 / 309.75 | 2 | 8 |
3 | 13 | 1340.76 | 18 | 14.76 | 2168 | 576 | 2.51 / 310.33 | 2 | 10 |
4 | 13 | 767.28 | 18 | 14.88 | 1407 | 377 | 2.88 / 310.71 | 2 | 10 |
5 | 13 | 210.68 | 18 | 15.04 | 636 | 172 | 3.06 / 310.88 | 2 | 11 |
6 | 8 | -0.40 | 165 | 15.05 | 328 | 815 | 3.87 / 311.69 | 2 | 15 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 30 | 15.02 | 492 | 222 | 0.22 / 304.17 | 2 | 13 |
2 | 7 | 2003.28 | 39 | 14.67 | 3004 | 1719 | 1.94 / 305.89 | 2 | 8 |
3 | 13 | 1325.64 | 18 | 14.77 | 2154 | 573 | 2.51 / 306.46 | 2 | 8 |
4 | 13 | 833.12 | 18 | 14.87 | 1491 | 399 | 2.91 / 306.86 | 2 | 15 |
5 | 13 | 174.28 | 18 | 15.06 | 581 | 157 | 3.07 / 307.02 | 2 | 6 |
6 | 8 | -0.28 | 165 | 15.07 | 324 | 806 | 3.88 / 307.82 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 30 | 15.03 | 495 | 223 | 0.22 / 300.34 | 2 | 4 |
2 | 7 | 2004.40 | 38 | 14.68 | 2994 | 1670 | 1.89 / 302.01 | 2 | 7 |
3 | 13 | 1298.52 | 18 | 14.78 | 2123 | 565 | 2.46 / 302.58 | 2 | 11 |
4 | 13 | 815.24 | 18 | 14.88 | 1464 | 392 | 2.85 / 302.97 | 2 | 12 |
5 | 13 | 196.84 | 18 | 15.06 | 614 | 166 | 3.02 / 303.14 | 2 | 12 |
6 | 8 | 0.28 | 165 | 15.07 | 326 | 811 | 3.83 / 303.95 | 2 | 12 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 30 | 15.04 | 502 | 227 | 0.23 / 296.37 | 2 | 4 |
2 | 7 | 2004.52 | 38 | 14.68 | 2974 | 1659 | 1.89 / 298.03 | 2 | 7 |
3 | 13 | 1322.36 | 18 | 14.79 | 2134 | 568 | 2.45 / 298.60 | 2 | 9 |
4 | 13 | 792.40 | 18 | 14.89 | 1435 | 385 | 2.84 / 298.98 | 2 | 10 |
5 | 13 | 218.44 | 18 | 15.05 | 652 | 177 | 3.01 / 299.16 | 2 | 14 |
6 | 8 | 1.56 | 165 | 15.08 | 328 | 816 | 3.83 / 299.97 | 2 | 8 |
7 | 14 | 1.56 | 30 | 15.06 | 328 | 148 | 3.98 / 300.12 | 2 | 15 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 30 | 15.03 | 481 | 217 | 0.22 / 292.57 | 2 | 3 |
2 | 7 | 2004.32 | 38 | 14.68 | 2971 | 1657 | 1.87 / 294.22 | 2 | 7 |
3 | 13 | 1362.72 | 18 | 14.78 | 2177 | 579 | 2.45 / 294.80 | 2 | 9 |
4 | 13 | 779.56 | 18 | 14.91 | 1421 | 381 | 2.83 / 295.18 | 2 | 10 |
5 | 13 | 138.04 | 18 | 15.09 | 530 | 144 | 2.98 / 295.33 | 2 | 11 |
6 | 8 | -0.12 | 165 | 15.08 | 327 | 814 | 3.79 / 296.14 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 30 | 15.04 | 490 | 221 | 0.22 / 288.71 | 2 | 5 |
2 | 7 | 2006.84 | 38 | 14.68 | 3004 | 1676 | 1.90 / 290.39 | 2 | 7 |
3 | 13 | 1301.20 | 18 | 14.78 | 2128 | 566 | 2.46 / 290.95 | 2 | 10 |
4 | 13 | 864.80 | 18 | 14.87 | 1534 | 411 | 2.87 / 291.37 | 2 | 10 |
5 | 13 | 191.04 | 18 | 15.07 | 608 | 165 | 3.04 / 291.53 | 2 | 10 |
6 | 8 | -0.04 | 165 | 15.09 | 329 | 819 | 3.86 / 292.35 | 2 | 12 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 30 | 15.04 | 504 | 227 | 0.23 / 284.82 | 2 | 3 |
2 | 7 | 2003.40 | 39 | 14.68 | 2998 | 1716 | 1.94 / 286.54 | 2 | 8 |
3 | 13 | 1282.24 | 18 | 14.79 | 2091 | 557 | 2.50 / 287.10 | 2 | 11 |
4 | 13 | 833.80 | 18 | 14.88 | 1494 | 400 | 2.90 / 287.50 | 2 | 12 |
5 | 13 | 212.60 | 18 | 15.08 | 646 | 175 | 3.08 / 287.67 | 2 | 10 |
6 | 8 | 0.36 | 165 | 15.09 | 329 | 819 | 3.90 / 288.49 | 2 | 14 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 30 | 15.04 | 508 | 229 | 0.23 / 281.03 | 2 | 5 |
2 | 7 | 2008.16 | 38 | 14.69 | 3003 | 1676 | 1.91 / 282.71 | 2 | 8 |
3 | 13 | 1298.24 | 18 | 14.81 | 2117 | 564 | 2.47 / 283.27 | 2 | 11 |
4 | 13 | 729.08 | 18 | 14.94 | 1350 | 363 | 2.83 / 283.63 | 2 | 10 |
5 | 13 | 139.68 | 18 | 15.12 | 537 | 146 | 2.98 / 283.78 | 2 | 17 |
6 | 8 | 0.36 | 165 | 15.10 | 328 | 817 | 3.80 / 284.60 | 2 | 4 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 30 | 15.05 | 493 | 223 | 0.22 / 277.21 | 2 | 12 |
2 | 7 | 2007.00 | 38 | 14.69 | 2997 | 1673 | 1.90 / 278.88 | 2 | 6 |
3 | 13 | 1292.68 | 18 | 14.81 | 2106 | 561 | 2.46 / 279.44 | 2 | 10 |
4 | 13 | 805.24 | 18 | 14.92 | 1461 | 392 | 2.85 / 279.83 | 2 | 13 |
5 | 13 | 142.84 | 18 | 15.10 | 543 | 148 | 3.00 / 279.98 | 2 | 9 |
6 | 8 | 0.60 | 165 | 15.09 | 329 | 819 | 3.82 / 280.80 | 2 | 4 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 30 | 15.05 | 494 | 223 | 0.22 / 273.41 | 2 | 6 |
2 | 7 | 2003.68 | 38 | 14.69 | 3000 | 1675 | 1.90 / 275.08 | 2 | 8 |
3 | 13 | 1259.92 | 18 | 14.81 | 2061 | 549 | 2.45 / 275.63 | 2 | 12 |
4 | 13 | 782.36 | 18 | 14.91 | 1427 | 383 | 2.83 / 276.02 | 2 | 11 |
5 | 13 | 137.76 | 18 | 15.11 | 537 | 146 | 2.98 / 276.16 | 2 | 13 |
6 | 8 | 0.12 | 165 | 15.10 | 330 | 822 | 3.80 / 276.98 | 2 | 12 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 30 | 15.05 | 497 | 224 | 0.22 / 269.59 | 2 | 3 |
2 | 7 | 2003.20 | 38 | 14.69 | 3003 | 1676 | 1.90 / 271.26 | 2 | 7 |
3 | 13 | 1290.72 | 18 | 14.81 | 2102 | 560 | 2.46 / 271.82 | 2 | 12 |
4 | 13 | 801.80 | 18 | 14.92 | 1455 | 391 | 2.85 / 272.21 | 2 | 10 |
5 | 13 | 149.32 | 18 | 15.11 | 553 | 150 | 3.00 / 272.36 | 2 | 11 |
6 | 8 | 0.12 | 165 | 15.11 | 330 | 823 | 3.82 / 273.19 | 2 | 11 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 30 | 15.06 | 496 | 224 | 0.22 / 265.72 | 2 | 6 |
2 | 7 | 2005.72 | 38 | 14.69 | 3007 | 1679 | 1.90 / 267.40 | 2 | 7 |
3 | 13 | 1378.24 | 18 | 14.79 | 2224 | 592 | 2.49 / 267.99 | 2 | 10 |
4 | 13 | 782.80 | 18 | 14.93 | 1421 | 382 | 2.88 / 268.37 | 2 | 10 |
5 | 13 | 178.28 | 18 | 15.10 | 594 | 161 | 3.04 / 268.54 | 2 | 13 |
6 | 8 | 0.12 | 165 | 15.11 | 331 | 825 | 3.86 / 269.36 | 2 | 10 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 30 | 15.07 | 494 | 223 | 0.22 / 261.84 | 2 | 4 |
2 | 7 | 2006.32 | 39 | 14.69 | 3009 | 1724 | 1.95 / 263.56 | 2 | 8 |
3 | 13 | 1305.44 | 18 | 14.81 | 2124 | 566 | 2.51 / 264.13 | 2 | 10 |
4 | 13 | 818.04 | 18 | 14.91 | 1472 | 395 | 2.91 / 264.52 | 2 | 12 |
5 | 13 | 153.72 | 18 | 15.11 | 562 | 153 | 3.06 / 264.68 | 2 | 9 |
6 | 8 | -0.20 | 165 | 15.11 | 330 | 823 | 3.88 / 265.50 | 2 | 9 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 30 | 15.06 | 491 | 222 | 0.22 / 257.99 | 2 | 5 |
2 | 7 | 2004.48 | 38 | 14.71 | 2999 | 1676 | 1.90 / 259.67 | 2 | 7 |
3 | 13 | 1335.00 | 18 | 14.82 | 2145 | 572 | 2.47 / 260.24 | 2 | 9 |
4 | 13 | 803.12 | 18 | 14.93 | 1455 | 391 | 2.86 / 260.63 | 2 | 12 |
5 | 13 | 142.08 | 18 | 15.13 | 549 | 150 | 3.01 / 260.78 | 2 | 10 |
6 | 8 | 0.24 | 165 | 15.12 | 334 | 833 | 3.84 / 261.61 | 2 | 12 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 30 | 15.08 | 494 | 223 | 0.22 / 254.12 | 2 | 5 |
2 | 7 | 2003.96 | 39 | 14.70 | 2999 | 1719 | 1.94 / 255.84 | 2 | 8 |
3 | 13 | 1340.36 | 18 | 14.81 | 2171 | 579 | 2.52 / 256.42 | 2 | 10 |
4 | 13 | 756.04 | 18 | 14.94 | 1384 | 372 | 2.89 / 256.79 | 2 | 13 |
5 | 13 | 158.28 | 18 | 15.12 | 569 | 155 | 3.05 / 256.95 | 2 | 11 |
6 | 8 | 0.52 | 165 | 15.12 | 330 | 823 | 3.87 / 257.77 | 2 | 11 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 30 | 15.08 | 499 | 226 | 0.23 / 250.31 | 2 | 8 |
2 | 7 | 2004.68 | 38 | 14.70 | 3004 | 1678 | 1.90 / 251.99 | 2 | 6 |
3 | 13 | 1329.80 | 18 | 14.81 | 2162 | 576 | 2.48 / 252.57 | 2 | 11 |
4 | 13 | 756.72 | 18 | 14.96 | 1391 | 375 | 2.85 / 252.94 | 2 | 9 |
5 | 13 | 112.16 | 18 | 15.15 | 500 | 136 | 2.99 / 253.08 | 2 | 11 |
6 | 8 | -0.20 | 165 | 15.13 | 329 | 821 | 3.81 / 253.90 | 2 | 7 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 30 | 15.08 | 483 | 219 | 0.22 / 246.48 | 2 | 4 |
2 | 7 | 2008.76 | 38 | 14.70 | 3011 | 1682 | 1.90 / 248.16 | 2 | 7 |
3 | 13 | 1286.44 | 18 | 14.82 | 2096 | 559 | 2.46 / 248.72 | 2 | 10 |
4 | 13 | 766.04 | 18 | 14.93 | 1395 | 375 | 2.83 / 249.10 | 2 | 13 |
5 | 13 | 162.52 | 18 | 15.13 | 574 | 156 | 2.99 / 249.25 | 2 | 8 |
6 | 8 | -0.16 | 165 | 15.12 | 333 | 831 | 3.82 / 250.09 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 30 | 15.07 | 495 | 224 | 0.22 / 242.61 | 2 | 3 |
2 | 7 | 2003.28 | 39 | 14.70 | 3007 | 1724 | 1.95 / 244.33 | 2 | 7 |
3 | 13 | 1331.92 | 18 | 14.82 | 2156 | 575 | 2.52 / 244.91 | 2 | 9 |
4 | 13 | 759.16 | 18 | 14.96 | 1394 | 375 | 2.90 / 245.28 | 2 | 14 |
5 | 13 | 151.16 | 18 | 15.13 | 556 | 151 | 3.05 / 245.43 | 2 | 15 |
6 | 8 | 0.00 | 165 | 15.13 | 333 | 831 | 3.88 / 246.26 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 30 | 15.08 | 493 | 223 | 0.22 / 238.80 | 2 | 6 |
2 | 7 | 2004.92 | 38 | 14.69 | 3001 | 1675 | 1.90 / 240.47 | 2 | 8 |
3 | 13 | 1332.04 | 18 | 14.80 | 2167 | 577 | 2.48 / 241.05 | 2 | 10 |
4 | 13 | 720.08 | 18 | 14.97 | 1338 | 361 | 2.84 / 241.41 | 2 | 13 |
5 | 13 | 124.32 | 18 | 15.14 | 518 | 141 | 2.98 / 241.55 | 2 | 13 |
6 | 8 | 0.32 | 165 | 15.13 | 333 | 831 | 3.81 / 242.38 | 2 | 8 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 30 | 15.08 | 498 | 225 | 0.23 / 234.93 | 2 | 7 |
2 | 7 | 2008.96 | 38 | 14.70 | 3009 | 1681 | 1.91 / 236.62 | 2 | 7 |
3 | 13 | 1341.68 | 18 | 14.82 | 2176 | 580 | 2.49 / 237.20 | 2 | 10 |
4 | 13 | 797.80 | 18 | 14.94 | 1446 | 389 | 2.88 / 237.58 | 2 | 10 |
5 | 13 | 182.76 | 18 | 15.12 | 599 | 163 | 3.04 / 237.75 | 2 | 17 |
6 | 8 | 0.00 | 165 | 15.13 | 331 | 826 | 3.86 / 238.57 | 2 | 10 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 30 | 15.10 | 494 | 224 | 0.22 / 231.11 | 2 | 5 |
2 | 7 | 2004.04 | 38 | 14.70 | 2997 | 1674 | 1.90 / 232.78 | 2 | 7 |
3 | 13 | 1337.32 | 18 | 14.82 | 2178 | 581 | 2.48 / 233.36 | 2 | 9 |
4 | 13 | 758.00 | 18 | 14.96 | 1384 | 373 | 2.85 / 233.74 | 2 | 11 |
5 | 13 | 157.16 | 18 | 15.13 | 561 | 153 | 3.00 / 233.89 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.13 | 329 | 821 | 3.83 / 234.71 | 2 | 13 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 30 | 15.08 | 496 | 224 | 0.22 / 227.25 | 2 | 5 |
2 | 7 | 2006.32 | 38 | 14.72 | 3006 | 1681 | 1.91 / 228.94 | 2 | 8 |
3 | 13 | 1332.64 | 18 | 14.83 | 2167 | 578 | 2.48 / 229.51 | 2 | 10 |
4 | 13 | 796.44 | 18 | 14.96 | 1447 | 390 | 2.87 / 229.90 | 2 | 11 |
5 | 13 | 143.56 | 18 | 15.16 | 547 | 149 | 3.02 / 230.05 | 2 | 8 |
6 | 8 | 0.40 | 165 | 15.15 | 332 | 830 | 3.85 / 230.88 | 2 | 12 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 30 | 15.07 | 499 | 226 | 0.23 / 223.46 | 2 | 5 |
2 | 7 | 2003.00 | 38 | 14.69 | 2999 | 1674 | 1.90 / 225.13 | 2 | 7 |
3 | 13 | 1246.72 | 18 | 14.83 | 2035 | 543 | 2.44 / 225.67 | 2 | 10 |
4 | 13 | 776.12 | 18 | 14.96 | 1419 | 382 | 2.83 / 226.06 | 2 | 13 |
5 | 13 | 158.84 | 18 | 15.15 | 565 | 154 | 2.98 / 226.21 | 2 | 11 |
6 | 8 | 0.08 | 165 | 15.13 | 329 | 821 | 3.80 / 227.03 | 2 | 6 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 15.09 | 508 | 230 | 0.23 / 219.65 | 2 | 3 |
2 | 7 | 2002.76 | 38 | 14.69 | 2991 | 1670 | 1.90 / 221.32 | 2 | 7 |
3 | 13 | 1288.72 | 18 | 14.83 | 2104 | 562 | 2.46 / 221.88 | 2 | 10 |
4 | 13 | 755.40 | 18 | 14.95 | 1378 | 371 | 2.83 / 222.25 | 2 | 13 |
5 | 13 | 161.80 | 18 | 15.13 | 570 | 155 | 2.99 / 222.41 | 2 | 9 |
6 | 8 | 0.04 | 165 | 15.13 | 329 | 821 | 3.81 / 223.23 | 2 | 7 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 30 | 15.10 | 491 | 222 | 0.22 / 215.83 | 2 | 5 |
2 | 7 | 2004.16 | 38 | 14.70 | 3004 | 1678 | 1.90 / 217.51 | 2 | 6 |
3 | 13 | 1285.92 | 18 | 14.85 | 2108 | 563 | 2.46 / 218.08 | 2 | 12 |
4 | 13 | 755.96 | 18 | 14.97 | 1394 | 376 | 2.84 / 218.45 | 2 | 12 |
5 | 13 | 114.40 | 18 | 15.17 | 505 | 138 | 2.98 / 218.59 | 2 | 12 |
6 | 8 | 0.04 | 165 | 15.14 | 333 | 832 | 3.81 / 219.42 | 2 | 13 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 30 | 15.10 | 489 | 222 | 0.22 / 211.96 | 2 | 4 |
2 | 7 | 2001.88 | 38 | 14.70 | 2998 | 1675 | 1.90 / 213.63 | 2 | 6 |
3 | 13 | 1286.08 | 18 | 14.84 | 2104 | 562 | 2.46 / 214.19 | 2 | 12 |
4 | 13 | 894.12 | 18 | 14.93 | 1579 | 424 | 2.88 / 214.62 | 2 | 11 |
5 | 13 | 152.76 | 18 | 15.13 | 561 | 153 | 3.04 / 214.77 | 2 | 14 |
6 | 8 | 0.20 | 165 | 15.13 | 337 | 841 | 3.88 / 215.61 | 2 | 9 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 30 | 15.10 | 493 | 223 | 0.22 / 208.15 | 2 | 3 |
2 | 7 | 2005.08 | 38 | 14.69 | 2993 | 1671 | 1.89 / 209.82 | 2 | 7 |
3 | 13 | 1326.72 | 18 | 14.81 | 2149 | 573 | 2.47 / 210.39 | 2 | 11 |
4 | 13 | 752.68 | 18 | 14.96 | 1385 | 373 | 2.84 / 210.76 | 2 | 14 |
5 | 13 | 108.04 | 18 | 15.15 | 498 | 136 | 2.98 / 210.90 | 2 | 14 |
6 | 8 | 0.12 | 165 | 15.14 | 335 | 837 | 3.81 / 211.74 | 2 | 10 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 30 | 15.09 | 498 | 225 | 0.23 / 204.31 | 2 | 5 |
2 | 7 | 2002.84 | 38 | 14.70 | 3007 | 1680 | 1.91 / 205.99 | 2 | 8 |
3 | 13 | 1277.24 | 18 | 14.83 | 2091 | 558 | 2.46 / 206.55 | 2 | 10 |
4 | 13 | 790.36 | 18 | 14.96 | 1441 | 388 | 2.85 / 206.93 | 2 | 13 |
5 | 13 | 170.48 | 18 | 15.15 | 584 | 159 | 3.01 / 207.09 | 2 | 9 |
6 | 8 | -0.40 | 165 | 15.16 | 332 | 830 | 3.84 / 207.92 | 2 | 8 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 30 | 15.11 | 493 | 223 | 0.22 / 200.49 | 2 | 3 |
2 | 7 | 2007.08 | 38 | 14.70 | 3003 | 1677 | 1.90 / 202.17 | 2 | 8 |
3 | 13 | 1280.36 | 18 | 14.84 | 2091 | 559 | 2.46 / 202.72 | 2 | 10 |
4 | 13 | 791.20 | 18 | 14.94 | 1431 | 385 | 2.84 / 203.11 | 2 | 12 |
5 | 13 | 138.76 | 18 | 15.16 | 541 | 148 | 2.99 / 203.26 | 2 | 12 |
6 | 8 | 0.28 | 165 | 15.15 | 330 | 825 | 3.82 / 204.08 | 2 | 9 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.96 | 30 | 15.11 | 511 | 232 | 0.23 / 196.66 | 2 | 3 |
2 | 7 | 2005.08 | 38 | 14.70 | 3002 | 1677 | 1.91 / 198.34 | 2 | 7 |
3 | 13 | 1327.08 | 18 | 14.83 | 2149 | 574 | 2.48 / 198.91 | 2 | 10 |
4 | 13 | 754.12 | 18 | 14.97 | 1381 | 372 | 2.85 / 199.29 | 2 | 12 |
5 | 13 | 144.64 | 18 | 15.16 | 546 | 149 | 3.00 / 199.44 | 2 | 15 |
6 | 8 | 0.24 | 165 | 15.15 | 332 | 830 | 3.83 / 200.26 | 2 | 8 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 30 | 15.10 | 508 | 230 | 0.23 / 192.79 | 2 | 3 |
2 | 7 | 2003.36 | 38 | 14.72 | 2997 | 1676 | 1.91 / 194.47 | 2 | 6 |
3 | 13 | 1377.80 | 18 | 14.83 | 2220 | 593 | 2.50 / 195.06 | 2 | 11 |
4 | 13 | 773.40 | 18 | 14.97 | 1417 | 382 | 2.88 / 195.44 | 2 | 12 |
5 | 13 | 161.64 | 18 | 15.17 | 571 | 156 | 3.04 / 195.60 | 2 | 13 |
6 | 8 | 0.08 | 165 | 15.16 | 333 | 833 | 3.87 / 196.43 | 2 | 17 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 30 | 15.10 | 499 | 226 | 0.23 / 188.95 | 2 | 3 |
2 | 7 | 2002.96 | 38 | 14.71 | 2987 | 1670 | 1.90 / 190.62 | 2 | 7 |
3 | 13 | 1288.28 | 18 | 14.84 | 2100 | 561 | 2.46 / 191.18 | 2 | 10 |
4 | 13 | 764.64 | 18 | 14.96 | 1400 | 377 | 2.83 / 191.56 | 2 | 12 |
5 | 13 | 192.68 | 18 | 15.15 | 615 | 168 | 3.00 / 191.72 | 2 | 12 |
6 | 8 | 0.12 | 165 | 15.16 | 335 | 838 | 3.84 / 192.56 | 2 | 10 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 30 | 15.11 | 500 | 227 | 0.23 / 185.10 | 2 | 3 |
2 | 7 | 2003.56 | 38 | 14.71 | 3008 | 1681 | 1.91 / 186.78 | 2 | 8 |
3 | 13 | 1254.72 | 18 | 14.87 | 2052 | 549 | 2.46 / 187.33 | 2 | 12 |
4 | 13 | 815.64 | 18 | 14.96 | 1474 | 397 | 2.85 / 187.73 | 2 | 11 |
5 | 13 | 192.20 | 18 | 15.17 | 615 | 168 | 3.02 / 187.90 | 2 | 13 |
6 | 8 | 0.00 | 165 | 15.17 | 330 | 826 | 3.85 / 188.72 | 2 | 16 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 30 | 15.11 | 497 | 225 | 0.23 / 181.26 | 2 | 3 |
2 | 7 | 2002.76 | 38 | 14.71 | 2999 | 1676 | 1.90 / 182.94 | 2 | 7 |
3 | 13 | 1284.92 | 18 | 14.85 | 2093 | 559 | 2.46 / 183.50 | 2 | 10 |
4 | 13 | 755.60 | 18 | 14.99 | 1388 | 375 | 2.84 / 183.87 | 2 | 13 |
5 | 13 | 191.56 | 18 | 15.16 | 614 | 168 | 3.00 / 184.04 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.17 | 333 | 834 | 3.84 / 184.87 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 30 | 15.13 | 505 | 229 | 0.23 / 177.38 | 2 | 4 |
2 | 7 | 2004.40 | 38 | 14.71 | 2997 | 1675 | 1.90 / 179.05 | 2 | 7 |
3 | 13 | 1379.68 | 18 | 14.82 | 2224 | 593 | 2.50 / 179.64 | 2 | 10 |
4 | 13 | 791.72 | 18 | 14.97 | 1440 | 388 | 2.89 / 180.03 | 2 | 13 |
5 | 13 | 180.48 | 18 | 15.16 | 604 | 165 | 3.05 / 180.20 | 2 | 13 |
6 | 8 | -0.36 | 165 | 15.17 | 336 | 841 | 3.89 / 181.04 | 2 | 12 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 30 | 15.12 | 514 | 233 | 0.23 / 173.44 | 2 | 5 |
2 | 7 | 2005.36 | 39 | 14.72 | 3000 | 1722 | 1.96 / 175.16 | 2 | 6 |
3 | 13 | 1330.48 | 18 | 14.84 | 2169 | 579 | 2.53 / 175.74 | 2 | 10 |
4 | 13 | 805.96 | 18 | 14.97 | 1460 | 393 | 2.93 / 176.13 | 2 | 13 |
5 | 13 | 181.64 | 18 | 15.17 | 606 | 165 | 3.09 / 176.30 | 2 | 14 |
6 | 8 | 0.64 | 165 | 15.17 | 338 | 846 | 3.94 / 177.15 | 2 | 8 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 30 | 15.13 | 504 | 229 | 0.23 / 169.52 | 2 | 5 |
2 | 7 | 2005.80 | 39 | 14.71 | 3001 | 1722 | 1.95 / 171.24 | 2 | 7 |
3 | 13 | 1341.56 | 18 | 14.84 | 2181 | 583 | 2.53 / 171.82 | 2 | 9 |
4 | 13 | 804.84 | 18 | 14.98 | 1460 | 394 | 2.93 / 172.22 | 2 | 12 |
5 | 13 | 98.72 | 18 | 15.19 | 486 | 133 | 3.06 / 172.35 | 2 | 8 |
6 | 8 | 0.20 | 165 | 15.17 | 342 | 856 | 3.92 / 173.21 | 2 | 8 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 30 | 15.13 | 515 | 234 | 0.23 / 165.66 | 2 | 6 |
2 | 7 | 2003.84 | 38 | 14.71 | 3004 | 1679 | 1.91 / 167.34 | 2 | 7 |
3 | 13 | 1295.20 | 18 | 14.86 | 2128 | 569 | 2.48 / 167.91 | 2 | 9 |
4 | 13 | 763.96 | 18 | 15.00 | 1402 | 379 | 2.86 / 168.28 | 2 | 12 |
5 | 13 | 158.24 | 18 | 15.18 | 568 | 155 | 3.02 / 168.44 | 2 | 8 |
6 | 8 | -0.04 | 165 | 15.17 | 340 | 851 | 3.87 / 169.29 | 2 | 12 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 30 | 15.14 | 507 | 230 | 0.23 / 161.79 | 2 | 6 |
2 | 7 | 2008.24 | 38 | 14.71 | 3000 | 1677 | 1.91 / 163.47 | 2 | 7 |
3 | 13 | 1289.80 | 18 | 14.86 | 2108 | 564 | 2.47 / 164.03 | 2 | 11 |
4 | 13 | 761.96 | 18 | 15.00 | 1398 | 377 | 2.85 / 164.41 | 2 | 11 |
5 | 13 | 149.16 | 18 | 15.18 | 561 | 153 | 3.00 / 164.56 | 2 | 19 |
6 | 8 | 0.16 | 165 | 15.18 | 344 | 862 | 3.86 / 165.42 | 2 | 8 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 30 | 15.15 | 514 | 234 | 0.23 / 157.88 | 2 | 4 |
2 | 7 | 2004.52 | 38 | 14.74 | 3009 | 1685 | 1.92 / 159.56 | 2 | 9 |
3 | 13 | 1338.28 | 18 | 14.87 | 2173 | 582 | 2.50 / 160.14 | 2 | 9 |
4 | 13 | 808.80 | 18 | 15.00 | 1470 | 397 | 2.90 / 160.54 | 2 | 10 |
5 | 13 | 190.40 | 18 | 15.19 | 613 | 168 | 3.07 / 160.71 | 2 | 12 |
6 | 8 | 0.04 | 165 | 15.19 | 340 | 852 | 3.92 / 161.56 | 2 | 16 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 30 | 15.15 | 516 | 235 | 0.23 / 153.93 | 2 | 3 |
2 | 7 | 2007.68 | 39 | 14.74 | 3008 | 1729 | 1.96 / 155.66 | 2 | 6 |
3 | 13 | 1297.64 | 18 | 14.90 | 2117 | 568 | 2.53 / 156.23 | 2 | 10 |
4 | 13 | 811.00 | 18 | 15.01 | 1469 | 397 | 2.93 / 156.62 | 2 | 10 |
5 | 13 | 182.60 | 18 | 15.20 | 605 | 166 | 3.09 / 156.79 | 2 | 6 |
6 | 8 | -0.44 | 165 | 15.21 | 340 | 853 | 3.95 / 157.64 | 2 | 11 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 30 | 15.15 | 521 | 237 | 0.24 / 150.05 | 2 | 8 |
2 | 7 | 2003.80 | 38 | 14.74 | 3008 | 1685 | 1.92 / 151.74 | 2 | 5 |
3 | 13 | 1372.40 | 18 | 14.87 | 2222 | 595 | 2.52 / 152.33 | 2 | 10 |
4 | 13 | 744.56 | 18 | 15.03 | 1382 | 374 | 2.89 / 152.71 | 2 | 11 |
5 | 13 | 98.16 | 18 | 15.22 | 489 | 134 | 3.02 / 152.84 | 2 | 18 |
6 | 8 | -0.28 | 165 | 15.21 | 341 | 856 | 3.88 / 153.70 | 2 | 15 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 30 | 15.16 | 511 | 232 | 0.23 / 146.17 | 2 | 4 |
2 | 7 | 2005.12 | 38 | 14.74 | 3010 | 1686 | 1.92 / 147.85 | 2 | 7 |
3 | 13 | 1335.24 | 18 | 14.87 | 2169 | 581 | 2.50 / 148.43 | 2 | 11 |
4 | 13 | 755.56 | 18 | 15.04 | 1395 | 378 | 2.88 / 148.81 | 2 | 11 |
5 | 13 | 107.72 | 18 | 15.23 | 503 | 138 | 3.01 / 148.95 | 2 | 12 |
6 | 8 | 0.56 | 165 | 15.20 | 346 | 868 | 3.88 / 149.82 | 2 | 11 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 30 | 15.16 | 493 | 224 | 0.22 / 142.27 | 2 | 8 |
2 | 7 | 2003.36 | 38 | 14.74 | 3020 | 1692 | 1.92 / 143.96 | 2 | 6 |
3 | 13 | 1340.00 | 18 | 14.88 | 2176 | 583 | 2.50 / 144.54 | 2 | 9 |
4 | 13 | 801.00 | 18 | 15.03 | 1460 | 395 | 2.89 / 144.94 | 2 | 11 |
5 | 13 | 151.76 | 18 | 15.21 | 563 | 154 | 3.05 / 145.09 | 2 | 8 |
6 | 8 | -0.24 | 165 | 15.21 | 336 | 843 | 3.89 / 145.93 | 2 | 11 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 30 | 15.16 | 511 | 232 | 0.23 / 138.40 | 2 | 6 |
2 | 7 | 2006.28 | 38 | 14.74 | 3010 | 1686 | 1.92 / 140.09 | 2 | 7 |
3 | 13 | 1295.96 | 18 | 14.89 | 2109 | 565 | 2.48 / 140.65 | 2 | 10 |
4 | 13 | 768.76 | 18 | 15.02 | 1413 | 382 | 2.87 / 141.03 | 2 | 10 |
5 | 13 | 163.88 | 18 | 15.21 | 580 | 159 | 3.02 / 141.19 | 2 | 10 |
6 | 8 | 0.00 | 165 | 15.21 | 339 | 851 | 3.88 / 142.04 | 2 | 9 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 30 | 15.16 | 515 | 234 | 0.23 / 134.44 | 2 | 3 |
2 | 7 | 2007.72 | 39 | 14.74 | 3019 | 1736 | 1.97 / 136.18 | 2 | 7 |
3 | 13 | 1295.60 | 18 | 14.92 | 2114 | 568 | 2.54 / 136.75 | 2 | 12 |
4 | 13 | 813.08 | 18 | 15.02 | 1467 | 397 | 2.93 / 137.14 | 2 | 13 |
5 | 13 | 156.32 | 18 | 15.22 | 574 | 157 | 3.09 / 137.30 | 2 | 10 |
6 | 8 | -0.24 | 165 | 15.22 | 345 | 866 | 3.96 / 138.17 | 2 | 16 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 30 | 15.17 | 515 | 234 | 0.23 / 130.48 | 2 | 6 |
2 | 7 | 2007.72 | 38 | 14.77 | 3003 | 1685 | 1.92 / 132.17 | 2 | 8 |
3 | 13 | 1383.68 | 18 | 14.89 | 2239 | 600 | 2.52 / 132.77 | 2 | 11 |
4 | 13 | 836.92 | 18 | 15.02 | 1510 | 408 | 2.93 / 133.18 | 2 | 11 |
5 | 13 | 186.20 | 18 | 15.21 | 614 | 168 | 3.10 / 133.34 | 2 | 9 |
6 | 8 | -0.12 | 165 | 15.22 | 345 | 866 | 3.96 / 134.21 | 2 | 14 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 30 | 15.16 | 513 | 233 | 0.23 / 126.55 | 2 | 4 |
2 | 7 | 2005.04 | 38 | 14.77 | 3012 | 1691 | 1.92 / 128.24 | 2 | 7 |
3 | 13 | 1382.04 | 18 | 14.91 | 2237 | 600 | 2.52 / 128.84 | 2 | 9 |
4 | 13 | 793.28 | 18 | 15.05 | 1443 | 391 | 2.92 / 129.23 | 2 | 13 |
5 | 13 | 141.72 | 18 | 15.23 | 554 | 152 | 3.07 / 129.39 | 2 | 13 |
6 | 8 | -0.36 | 165 | 15.23 | 343 | 862 | 3.93 / 130.25 | 2 | 10 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 30 | 15.18 | 504 | 230 | 0.23 / 122.65 | 2 | 6 |
2 | 7 | 2004.68 | 38 | 14.76 | 3012 | 1689 | 1.92 / 124.34 | 2 | 7 |
3 | 13 | 1360.88 | 18 | 14.90 | 2200 | 590 | 2.51 / 124.93 | 2 | 9 |
4 | 13 | 778.56 | 18 | 15.04 | 1432 | 388 | 2.90 / 125.32 | 2 | 11 |
5 | 13 | 170.68 | 18 | 15.22 | 591 | 162 | 3.06 / 125.48 | 2 | 9 |
6 | 8 | 0.32 | 165 | 15.23 | 334 | 839 | 3.90 / 126.32 | 2 | 9 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 30 | 15.17 | 512 | 233 | 0.23 / 118.78 | 2 | 4 |
2 | 7 | 2005.64 | 38 | 14.75 | 3021 | 1693 | 1.93 / 120.47 | 2 | 6 |
3 | 13 | 1292.60 | 18 | 14.91 | 2120 | 569 | 2.50 / 121.04 | 2 | 11 |
4 | 13 | 777.08 | 18 | 15.04 | 1427 | 386 | 2.88 / 121.43 | 2 | 11 |
5 | 13 | 95.76 | 18 | 15.24 | 488 | 134 | 3.02 / 121.56 | 2 | 15 |
6 | 8 | 0.04 | 165 | 15.22 | 343 | 861 | 3.88 / 122.42 | 2 | 15 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 30 | 15.17 | 509 | 232 | 0.23 / 114.84 | 2 | 8 |
2 | 7 | 2005.32 | 38 | 14.76 | 3010 | 1688 | 1.92 / 116.53 | 2 | 7 |
3 | 13 | 1338.84 | 18 | 14.90 | 2174 | 583 | 2.50 / 117.11 | 2 | 11 |
4 | 13 | 803.72 | 18 | 15.04 | 1466 | 397 | 2.90 / 117.51 | 2 | 13 |
5 | 13 | 182.04 | 18 | 15.22 | 613 | 168 | 3.07 / 117.67 | 2 | 8 |
6 | 8 | 0.60 | 165 | 15.23 | 346 | 869 | 3.94 / 118.54 | 2 | 7 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 30 | 15.16 | 527 | 240 | 0.24 / 110.94 | 2 | 3 |
2 | 7 | 2008.20 | 38 | 14.75 | 3018 | 1692 | 1.93 / 112.63 | 2 | 6 |
3 | 13 | 1265.44 | 18 | 14.91 | 2076 | 557 | 2.49 / 113.18 | 2 | 10 |
4 | 13 | 830.00 | 18 | 15.01 | 1499 | 405 | 2.89 / 113.59 | 2 | 10 |
5 | 13 | 159.24 | 18 | 15.22 | 575 | 158 | 3.05 / 113.75 | 2 | 11 |
6 | 8 | 0.68 | 165 | 15.22 | 342 | 859 | 3.91 / 114.61 | 2 | 8 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 30 | 15.19 | 515 | 235 | 0.23 / 107.03 | 2 | 9 |
2 | 7 | 2002.88 | 38 | 14.76 | 3005 | 1685 | 1.92 / 108.71 | 2 | 6 |
3 | 13 | 1295.00 | 18 | 14.91 | 2124 | 570 | 2.49 / 109.28 | 2 | 11 |
4 | 13 | 778.84 | 18 | 15.03 | 1426 | 386 | 2.88 / 109.67 | 2 | 11 |
5 | 13 | 170.92 | 18 | 15.22 | 591 | 162 | 3.04 / 109.83 | 2 | 16 |
6 | 8 | 0.08 | 165 | 15.22 | 345 | 866 | 3.90 / 110.70 | 2 | 13 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 30 | 15.19 | 512 | 233 | 0.23 / 103.10 | 2 | 3 |
2 | 7 | 2003.52 | 39 | 14.77 | 3023 | 1741 | 1.97 / 104.84 | 2 | 6 |
3 | 13 | 1297.40 | 18 | 14.93 | 2125 | 571 | 2.55 / 105.41 | 2 | 9 |
4 | 13 | 726.72 | 18 | 15.08 | 1356 | 368 | 2.91 / 105.78 | 2 | 12 |
5 | 13 | 124.88 | 18 | 15.25 | 529 | 145 | 3.06 / 105.92 | 2 | 13 |
6 | 8 | 0.00 | 165 | 15.24 | 345 | 868 | 3.93 / 106.79 | 2 | 13 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 30 | 15.20 | 516 | 235 | 0.24 / 99.24 | 2 | 6 |
2 | 7 | 2003.44 | 38 | 14.77 | 3023 | 1697 | 1.93 / 100.93 | 2 | 6 |
3 | 13 | 1248.80 | 18 | 14.95 | 2063 | 555 | 2.49 / 101.49 | 2 | 10 |
4 | 13 | 690.76 | 18 | 15.09 | 1317 | 358 | 2.84 / 101.85 | 2 | 13 |
5 | 13 | 140.48 | 18 | 15.26 | 551 | 151 | 3.00 / 102.00 | 2 | 12 |
6 | 8 | 0.52 | 165 | 15.24 | 345 | 868 | 3.86 / 102.87 | 2 | 12 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 30 | 15.19 | 516 | 235 | 0.24 / 95.24 | 2 | 3 |
2 | 7 | 2004.12 | 39 | 14.78 | 3023 | 1743 | 1.98 / 96.98 | 2 | 8 |
3 | 13 | 1303.80 | 18 | 14.94 | 2139 | 575 | 2.55 / 97.56 | 2 | 10 |
4 | 13 | 815.32 | 18 | 15.05 | 1484 | 402 | 2.95 / 97.96 | 2 | 10 |
5 | 13 | 188.60 | 18 | 15.24 | 621 | 170 | 3.13 / 98.13 | 2 | 14 |
6 | 8 | -0.24 | 165 | 15.25 | 347 | 873 | 4.00 / 99.00 | 2 | 16 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 30 | 15.22 | 510 | 233 | 0.23 / 91.29 | 2 | 3 |
2 | 7 | 2004.84 | 38 | 14.79 | 3021 | 1698 | 1.93 / 92.99 | 2 | 7 |
3 | 13 | 1344.24 | 18 | 14.93 | 2185 | 587 | 2.52 / 93.58 | 2 | 10 |
4 | 13 | 812.80 | 18 | 15.06 | 1479 | 401 | 2.92 / 93.98 | 2 | 11 |
5 | 13 | 163.36 | 18 | 15.25 | 589 | 162 | 3.08 / 94.14 | 2 | 9 |
6 | 8 | 0.40 | 165 | 15.25 | 344 | 866 | 3.95 / 95.00 | 2 | 16 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 30 | 15.21 | 498 | 227 | 0.23 / 87.38 | 2 | 2 |
2 | 7 | 2007.80 | 38 | 14.79 | 3037 | 1707 | 1.93 / 89.08 | 2 | 7 |
3 | 13 | 1293.36 | 18 | 14.94 | 2128 | 572 | 2.51 / 89.65 | 2 | 10 |
4 | 13 | 762.32 | 18 | 15.10 | 1417 | 385 | 2.89 / 90.04 | 2 | 12 |
5 | 13 | 151.32 | 18 | 15.26 | 571 | 157 | 3.05 / 90.20 | 2 | 7 |
6 | 8 | 0.04 | 165 | 15.26 | 342 | 861 | 3.91 / 91.06 | 2 | 12 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 30 | 15.21 | 516 | 235 | 0.24 / 83.47 | 2 | 3 |
2 | 7 | 2003.92 | 38 | 14.80 | 3012 | 1694 | 1.93 / 85.16 | 2 | 8 |
3 | 13 | 1331.92 | 18 | 14.94 | 2175 | 585 | 2.51 / 85.74 | 2 | 12 |
4 | 13 | 749.44 | 18 | 15.09 | 1390 | 378 | 2.89 / 86.12 | 2 | 13 |
5 | 13 | 181.16 | 18 | 15.26 | 610 | 168 | 3.06 / 86.29 | 2 | 8 |
6 | 8 | 0.16 | 165 | 15.26 | 341 | 859 | 3.92 / 87.15 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 30 | 15.24 | 487 | 223 | 0.22 / 79.55 | 2 | 4 |
2 | 7 | 2003.08 | 38 | 14.81 | 3017 | 1698 | 1.92 / 81.24 | 2 | 7 |
3 | 13 | 1328.56 | 18 | 14.96 | 2174 | 585 | 2.51 / 81.83 | 2 | 9 |
4 | 13 | 783.60 | 18 | 15.09 | 1442 | 392 | 2.90 / 82.22 | 2 | 10 |
5 | 13 | 131.08 | 18 | 15.28 | 537 | 148 | 3.05 / 82.37 | 2 | 9 |
6 | 8 | 0.12 | 165 | 15.27 | 342 | 862 | 3.91 / 83.23 | 2 | 4 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 30 | 15.22 | 510 | 233 | 0.23 / 75.66 | 2 | 3 |
2 | 7 | 2004.48 | 38 | 14.80 | 3022 | 1700 | 1.93 / 77.36 | 2 | 9 |
3 | 13 | 1277.28 | 18 | 14.96 | 2101 | 566 | 2.50 / 77.93 | 2 | 10 |
4 | 13 | 825.76 | 18 | 15.08 | 1494 | 406 | 2.90 / 78.33 | 2 | 10 |
5 | 13 | 115.20 | 18 | 15.28 | 515 | 142 | 3.05 / 78.47 | 2 | 11 |
6 | 8 | 0.00 | 165 | 15.28 | 337 | 850 | 3.90 / 79.32 | 2 | 11 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 30 | 15.22 | 510 | 233 | 0.23 / 71.69 | 2 | 4 |
2 | 7 | 2007.56 | 39 | 14.79 | 3024 | 1744 | 1.98 / 73.43 | 2 | 7 |
3 | 13 | 1291.56 | 18 | 14.98 | 2113 | 570 | 2.55 / 74.00 | 2 | 11 |
4 | 13 | 756.04 | 18 | 15.09 | 1405 | 382 | 2.93 / 74.38 | 2 | 13 |
5 | 13 | 184.40 | 18 | 15.26 | 616 | 169 | 3.10 / 74.55 | 2 | 5 |
6 | 8 | 0.36 | 165 | 15.27 | 347 | 874 | 3.97 / 75.43 | 2 | 18 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 30 | 15.23 | 500 | 228 | 0.23 / 67.80 | 2 | 6 |
2 | 7 | 2006.72 | 38 | 14.80 | 3030 | 1704 | 1.93 / 69.50 | 2 | 8 |
3 | 13 | 1318.28 | 18 | 14.96 | 2158 | 581 | 2.51 / 70.08 | 2 | 10 |
4 | 13 | 697.92 | 18 | 15.13 | 1325 | 361 | 2.87 / 70.44 | 2 | 9 |
5 | 13 | 101.84 | 18 | 15.30 | 504 | 139 | 3.01 / 70.58 | 2 | 12 |
6 | 8 | 0.32 | 165 | 15.28 | 346 | 872 | 3.89 / 71.46 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 30 | 15.23 | 514 | 235 | 0.23 / 63.93 | 2 | 4 |
2 | 7 | 2003.80 | 38 | 14.80 | 3024 | 1701 | 1.94 / 65.63 | 2 | 7 |
3 | 13 | 1243.52 | 18 | 14.98 | 2063 | 556 | 2.49 / 66.19 | 2 | 10 |
4 | 13 | 680.64 | 18 | 15.14 | 1306 | 356 | 2.85 / 66.54 | 2 | 11 |
5 | 13 | 131.20 | 18 | 15.29 | 545 | 150 | 3.00 / 66.69 | 2 | 9 |
6 | 8 | -0.68 | 165 | 15.27 | 349 | 879 | 3.88 / 67.57 | 2 | 17 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 30 | 15.24 | 510 | 233 | 0.23 / 59.94 | 2 | 3 |
2 | 7 | 2007.64 | 38 | 14.81 | 3033 | 1707 | 1.94 / 61.64 | 2 | 6 |
3 | 13 | 1335.00 | 18 | 14.97 | 2185 | 589 | 2.53 / 62.23 | 2 | 9 |
4 | 13 | 848.16 | 18 | 15.08 | 1532 | 416 | 2.94 / 62.65 | 2 | 10 |
5 | 13 | 182.76 | 18 | 15.27 | 620 | 170 | 3.12 / 62.82 | 2 | 16 |
6 | 8 | 0.16 | 165 | 15.28 | 347 | 875 | 3.99 / 63.69 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 30 | 15.23 | 513 | 234 | 0.23 / 56.01 | 2 | 3 |
2 | 7 | 2003.80 | 39 | 14.81 | 3022 | 1745 | 1.98 / 57.75 | 2 | 7 |
3 | 13 | 1285.60 | 18 | 14.97 | 2114 | 570 | 2.55 / 58.32 | 2 | 13 |
4 | 13 | 753.40 | 18 | 15.10 | 1406 | 382 | 2.93 / 58.71 | 2 | 10 |
5 | 13 | 67.16 | 18 | 15.31 | 454 | 125 | 3.06 / 58.83 | 2 | 8 |
6 | 8 | 0.16 | 165 | 15.28 | 346 | 872 | 3.93 / 59.70 | 2 | 9 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 30 | 15.24 | 510 | 233 | 0.23 / 52.08 | 2 | 3 |
2 | 7 | 2006.28 | 38 | 14.82 | 3028 | 1705 | 1.94 / 53.78 | 2 | 7 |
3 | 13 | 1281.08 | 18 | 14.99 | 2116 | 571 | 2.51 / 54.36 | 2 | 11 |
4 | 13 | 757.64 | 18 | 15.12 | 1404 | 382 | 2.89 / 54.74 | 2 | 11 |
5 | 13 | 135.72 | 18 | 15.30 | 550 | 151 | 3.04 / 54.89 | 2 | 13 |
6 | 8 | 0.12 | 165 | 15.29 | 351 | 886 | 3.93 / 55.77 | 2 | 10 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 30 | 15.24 | 511 | 234 | 0.23 / 48.12 | 2 | 3 |
2 | 7 | 2003.48 | 38 | 14.82 | 3025 | 1704 | 1.94 / 49.83 | 2 | 7 |
3 | 13 | 1323.92 | 18 | 14.97 | 2174 | 586 | 2.52 / 50.41 | 2 | 10 |
4 | 13 | 778.48 | 18 | 15.10 | 1442 | 392 | 2.91 / 50.81 | 2 | 10 |
5 | 13 | 162.88 | 18 | 15.28 | 593 | 163 | 3.08 / 50.97 | 2 | 8 |
6 | 8 | 0.08 | 165 | 15.28 | 348 | 877 | 3.96 / 51.85 | 2 | 14 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 30 | 15.24 | 513 | 235 | 0.23 / 44.18 | 2 | 3 |
2 | 7 | 2007.20 | 38 | 14.81 | 3039 | 1710 | 1.94 / 45.89 | 2 | 6 |
3 | 13 | 1280.36 | 18 | 15.00 | 2112 | 570 | 2.52 / 46.46 | 2 | 10 |
4 | 13 | 798.92 | 18 | 15.10 | 1467 | 399 | 2.91 / 46.86 | 2 | 12 |
5 | 13 | 135.40 | 18 | 15.29 | 554 | 152 | 3.07 / 47.01 | 2 | 13 |
6 | 8 | 0.28 | 165 | 15.29 | 348 | 878 | 3.94 / 47.89 | 2 | 12 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 30 | 15.25 | 518 | 237 | 0.24 / 40.26 | 2 | 2 |
2 | 7 | 2004.16 | 38 | 14.82 | 3024 | 1703 | 1.94 / 41.96 | 2 | 7 |
3 | 13 | 1295.40 | 18 | 14.98 | 2133 | 575 | 2.52 / 42.54 | 2 | 10 |
4 | 13 | 761.20 | 18 | 15.11 | 1419 | 386 | 2.90 / 42.92 | 2 | 11 |
5 | 13 | 159.80 | 18 | 15.29 | 583 | 160 | 3.06 / 43.08 | 2 | 13 |
6 | 8 | 0.20 | 165 | 15.29 | 342 | 863 | 3.92 / 43.95 | 2 | 13 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 29 | 15.25 | 517 | 229 | 0.23 / 35.51 | 2 | 4 |
2 | 7 | 2006.96 | 74 | 14.71 | 3022 | 3290 | 3.52 / 38.80 | 2 | 8 |
3 | 13 | 361.24 | 18 | 15.25 | 875 | 240 | 3.76 / 39.04 | 2 | 11 |
4 | 13 | 18.04 | 18 | 15.34 | 381 | 105 | 3.86 / 39.15 | 2 | 12 |
5 | 8 | 0.12 | 165 | 15.30 | 347 | 876 | 4.74 / 40.02 | 2 | 16 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 29 | 15.27 | 522 | 231 | 0.23 / 30.79 | 2 | 4 |
2 | 7 | 2007.36 | 74 | 14.71 | 3020 | 3287 | 3.52 / 34.07 | 2 | 7 |
3 | 13 | 354.40 | 18 | 15.25 | 858 | 236 | 3.75 / 34.31 | 2 | 11 |
4 | 13 | 18.44 | 18 | 15.33 | 377 | 104 | 3.86 / 34.41 | 2 | 8 |
5 | 8 | 0.16 | 165 | 15.30 | 344 | 868 | 4.73 / 35.28 | 2 | 11 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 29 | 15.26 | 508 | 225 | 0.22 / 26.16 | 2 | 5 |
2 | 7 | 2004.00 | 74 | 14.72 | 3016 | 3285 | 3.51 / 29.45 | 2 | 7 |
3 | 13 | 364.52 | 18 | 15.26 | 872 | 240 | 3.75 / 29.69 | 2 | 10 |
4 | 8 | -0.08 | 165 | 15.31 | 343 | 866 | 4.62 / 30.56 | 2 | 16 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 28 | 15.27 | 515 | 220 | 0.22 / 21.38 | 2 | 8 |
2 | 3 | 1026.88 | 1 | 15.27 | 1815 | 28 | 0.25 / 21.41 | 2 | 9 |
3 | 7 | 2006.32 | 75 | 14.72 | 3015 | 3329 | 3.58 / 24.74 | 2 | 7 |
4 | 13 | 334.32 | 18 | 15.25 | 828 | 227 | 3.80 / 24.97 | 2 | 12 |
5 | 13 | 15.20 | 18 | 15.33 | 378 | 104 | 3.91 / 25.07 | 2 | 7 |
6 | 8 | -0.20 | 165 | 15.30 | 344 | 868 | 4.78 / 25.94 | 2 | 17 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 29 | 15.27 | 502 | 222 | 0.22 / 16.82 | 2 | 4 |
2 | 7 | 2005.52 | 74 | 14.73 | 3016 | 3288 | 3.51 / 20.10 | 2 | 7 |
3 | 13 | 235.16 | 18 | 15.29 | 687 | 189 | 3.70 / 20.29 | 2 | 9 |
4 | 8 | -0.16 | 165 | 15.31 | 344 | 869 | 4.57 / 21.16 | 2 | 10 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 28 | 15.28 | 503 | 215 | 0.22 / 12.92 | 2 | 5 |
2 | 7 | 1506.92 | 74 | 14.94 | 2371 | 2621 | 2.84 / 15.54 | 2 | 8 |
3 | 13 | 243.44 | 18 | 15.31 | 694 | 191 | 3.03 / 15.73 | 2 | 10 |
4 | 8 | 0.00 | 165 | 15.32 | 341 | 862 | 3.89 / 16.60 | 2 | 11 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 28 | 15.26 | 507 | 217 | 0.22 / 9.05 | 2 | 3 |
2 | 7 | 1527.32 | 74 | 14.93 | 2391 | 2642 | 2.86 / 11.69 | 2 | 7 |
3 | 13 | 143.68 | 18 | 15.34 | 551 | 152 | 3.01 / 11.85 | 2 | 8 |
4 | 8 | 0.20 | 165 | 15.32 | 340 | 859 | 3.87 / 12.71 | 2 | 12 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 31 | 15.27 | 499 | 236 | 0.24 / 5.19 | 2 | 6 |
2 | 3 | 860.44 | -3 | 15.62 | 0 | 0 | 0.00 / 5.19 | 2 | 6 |
3 | 7 | 1525.60 | 74 | 14.93 | 2387 | 2637 | 2.87 / 7.83 | 2 | 7 |
4 | 13 | 139.88 | 18 | 15.34 | 546 | 151 | 3.02 / 7.98 | 2 | 6 |
5 | 8 | 0.04 | 165 | 15.32 | 339 | 857 | 3.88 / 8.84 | 2 | 9 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 26 | 15.43 | 464 | 186 | 0.19 / 2.10 | 2 | 3 |
2 | 10 | 1001.56 | 2 | 15.23 | 1766 | 54 | 0.24 / 2.16 | 2 | 4 |
3 | 3 | 972.44 | -1 | 15.59 | 0 | 0 | 0.05 / 2.16 | 2 | 4 |
4 | 3 | 1066.08 | 2 | 15.25 | 1860 | 57 | 0.30 / 2.22 | 2 | 5 |
5 | 7 | 1001.24 | 74 | 15.09 | 1689 | 1886 | 2.18 / 4.10 | 2 | 10 |
6 | 8 | 0.04 | 165 | 15.34 | 337 | 853 | 3.04 / 4.95 | 2 | 13 |
Average= | 2.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 125.32 | 26 | 15.59 | 512 | 208 | 0.21 / 0.21 | 2 | 3 |
2 | 7 | 140.04 | 74 | 15.55 | 507 | 583 | 0.79 / 0.79 | 2 | 4 |
3 | 8 | 0.32 | 240 | 15.51 | 303 | 1128 | 1.92 / 1.92 | 2 | 17 |
Average= | 1.92 (KJ/cycle) |