SIO Argo Site:
Pump Diagnostics Page   



Serial= 3126 WMO= 5906775

Return

←PreviousNext→

Cycle 4 GMT 4/12/2022 15:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 33 15.25 412 207 0.21 / 11.65 2 3
2 3 1024.36 1 15.25 1676 26 0.23 / 11.67 2 5
3 7 1525.52 74 14.93 2182 2411 2.64 / 14.08 2 7
4 13 362.24 18 15.24 752 206 2.85 / 14.29 2 8
5 13 22.32 18 15.31 300 83 2.93 / 14.37 2 7
6 8 0.04 165 15.28 265 668 3.60 / 15.04 2 15
Average= 3.01
(KJ/cycle)

Cycle 3 GMT 3/12/2022 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 30 15.25 416 190 0.19 / 7.96 2 3
2 10 1003.72 3 15.21 1607 73 0.26 / 8.03 2 4
3 7 1524.00 75 14.93 2183 2444 2.71 / 10.47 2 6
4 13 359.56 18 15.25 751 206 2.91 / 10.68 2 8
5 13 20.76 18 15.32 300 83 3.00 / 10.76 2 8
6 8 0.08 165 15.28 268 676 3.67 / 11.44 2 14
Average= 2.86
(KJ/cycle)

Cycle 2 GMT 2/12/2022 16:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 31 15.26 416 197 0.20 / 4.41 2 2
2 3 957.28 -1 15.58 0 0 0.00 / 4.41 2 2
3 7 1509.92 74 14.95 2163 2393 2.59 / 6.80 2 6
4 13 351.68 18 15.25 741 203 2.79 / 7.00 2 9
5 13 21.40 18 15.32 301 83 2.88 / 7.09 2 7
6 8 0.12 165 15.28 269 678 3.55 / 7.77 2 12
Average= 2.59
(KJ/cycle)

Cycle 1 GMT 1/12/2022 16:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 26 15.43 375 150 0.15 / 1.69 2 2
2 10 1013.24 3 15.27 1597 73 0.22 / 1.76 2 3
3 3 1037.60 1 15.26 1668 25 0.25 / 1.79 2 5
4 7 998.40 74 15.10 1537 1717 1.97 / 3.51 2 8
5 8 0.08 165 15.32 279 705 2.67 / 4.21 2 15
Average= 2.11
(KJ/cycle)

Cycle 0 GMT 1/12/2022 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.28 26 15.57 451 183 0.18 / 0.18 2 2
2 7 184.92 74 15.53 462 531 0.71 / 0.71 2 3
3 8 0.32 240 15.50 222 826 1.54 / 1.54 2 9
Average= 1.54
(KJ/cycle)