SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 30 | 14.98 | 416 | 187 | 0.19 / 391.52 | 2 | 2 |
2 | 7 | 2004.48 | 29 | 14.90 | 2941 | 1271 | 1.46 / 392.79 | 2 | 3 |
3 | 13 | 1734.36 | 18 | 14.86 | 2601 | 696 | 2.15 / 393.48 | 2 | 5 |
4 | 13 | 1034.12 | 18 | 14.91 | 1703 | 457 | 2.61 / 393.94 | 2 | 3 |
5 | 13 | 475.04 | 18 | 14.98 | 935 | 252 | 2.86 / 394.19 | 2 | 3 |
6 | 13 | 35.88 | 18 | 15.04 | 318 | 86 | 2.95 / 394.28 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.02 | 261 | 647 | 3.60 / 394.93 | 2 | 8 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 30 | 14.98 | 421 | 189 | 0.19 / 387.84 | 2 | 2 |
2 | 7 | 2011.96 | 29 | 14.90 | 2959 | 1279 | 1.47 / 389.12 | 2 | 4 |
3 | 13 | 1738.44 | 18 | 14.85 | 2622 | 701 | 2.17 / 389.82 | 2 | 3 |
4 | 13 | 1138.28 | 18 | 14.90 | 1838 | 493 | 2.66 / 390.32 | 2 | 3 |
5 | 13 | 572.72 | 18 | 14.96 | 1072 | 289 | 2.95 / 390.61 | 2 | 2 |
6 | 13 | 30.88 | 18 | 15.05 | 308 | 83 | 3.03 / 390.69 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.03 | 259 | 642 | 3.68 / 391.33 | 2 | 6 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 30 | 15.00 | 416 | 187 | 0.19 / 384.27 | 2 | 2 |
2 | 7 | 2004.32 | 29 | 14.89 | 2943 | 1271 | 1.46 / 385.54 | 2 | 3 |
3 | 13 | 1604.20 | 18 | 14.85 | 2446 | 654 | 2.11 / 386.20 | 2 | 3 |
4 | 13 | 1054.04 | 18 | 14.90 | 1723 | 462 | 2.57 / 386.66 | 2 | 3 |
5 | 13 | 494.48 | 18 | 14.97 | 959 | 258 | 2.83 / 386.92 | 2 | 3 |
6 | 13 | 39.08 | 18 | 15.05 | 319 | 86 | 2.92 / 387.00 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.02 | 263 | 652 | 3.57 / 387.66 | 2 | 4 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 30 | 14.96 | 432 | 194 | 0.19 / 380.70 | 2 | 2 |
2 | 7 | 2008.80 | 29 | 14.90 | 2950 | 1275 | 1.47 / 381.97 | 2 | 2 |
3 | 13 | 1617.28 | 18 | 14.87 | 2470 | 661 | 2.13 / 382.63 | 2 | 3 |
4 | 13 | 1065.68 | 18 | 14.91 | 1738 | 466 | 2.60 / 383.10 | 2 | 4 |
5 | 13 | 475.12 | 18 | 15.00 | 935 | 252 | 2.85 / 383.35 | 2 | 3 |
6 | 13 | 38.68 | 18 | 15.04 | 324 | 88 | 2.94 / 383.44 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.03 | 260 | 645 | 3.58 / 384.08 | 2 | 6 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 30 | 14.99 | 428 | 192 | 0.19 / 377.07 | 2 | 2 |
2 | 7 | 2013.72 | 29 | 14.91 | 2964 | 1282 | 1.47 / 378.35 | 2 | 3 |
3 | 13 | 1610.96 | 18 | 14.88 | 2471 | 662 | 2.14 / 379.01 | 2 | 2 |
4 | 13 | 1053.32 | 18 | 14.91 | 1732 | 465 | 2.60 / 379.48 | 2 | 3 |
5 | 13 | 493.80 | 18 | 14.98 | 1003 | 270 | 2.87 / 379.75 | 2 | 3 |
6 | 13 | 38.84 | 18 | 15.05 | 340 | 92 | 2.96 / 379.84 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.03 | 267 | 662 | 3.63 / 380.50 | 2 | 9 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 30 | 15.01 | 412 | 186 | 0.19 / 373.38 | 2 | 2 |
2 | 7 | 2007.00 | 29 | 14.91 | 2956 | 1278 | 1.46 / 374.66 | 2 | 2 |
3 | 13 | 1620.88 | 18 | 14.86 | 2476 | 662 | 2.13 / 375.32 | 2 | 3 |
4 | 13 | 1196.64 | 18 | 14.89 | 1911 | 512 | 2.64 / 375.83 | 2 | 4 |
5 | 13 | 477.32 | 18 | 15.00 | 931 | 251 | 2.89 / 376.09 | 2 | 3 |
6 | 13 | 18.28 | 18 | 15.06 | 288 | 78 | 2.97 / 376.16 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.04 | 288 | 715 | 3.68 / 376.88 | 2 | 4 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 30 | 15.01 | 410 | 185 | 0.18 / 369.91 | 2 | 2 |
2 | 7 | 2007.88 | 29 | 14.91 | 2953 | 1277 | 1.46 / 371.19 | 2 | 3 |
3 | 13 | 1592.72 | 18 | 14.88 | 2433 | 652 | 2.11 / 371.84 | 2 | 4 |
4 | 13 | 1037.76 | 18 | 14.91 | 1697 | 455 | 2.57 / 372.30 | 2 | 3 |
5 | 13 | 489.40 | 18 | 14.99 | 955 | 258 | 2.83 / 372.55 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.06 | 258 | 641 | 3.47 / 373.20 | 2 | 6 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 30 | 14.99 | 410 | 184 | 0.18 / 366.37 | 2 | 2 |
2 | 7 | 2003.92 | 29 | 14.91 | 2950 | 1276 | 1.46 / 367.65 | 2 | 4 |
3 | 13 | 1609.16 | 18 | 14.89 | 2461 | 660 | 2.12 / 368.31 | 2 | 2 |
4 | 13 | 1174.64 | 18 | 14.90 | 1883 | 505 | 2.62 / 368.81 | 2 | 3 |
5 | 13 | 566.52 | 18 | 14.99 | 1057 | 285 | 2.91 / 369.10 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.04 | 254 | 630 | 3.54 / 369.73 | 2 | 4 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 30 | 15.01 | 423 | 190 | 0.19 / 362.57 | 2 | 2 |
2 | 7 | 2011.08 | 29 | 14.90 | 2962 | 1280 | 1.47 / 363.85 | 2 | 3 |
3 | 13 | 1610.84 | 18 | 14.89 | 2502 | 671 | 2.14 / 364.52 | 2 | 3 |
4 | 13 | 1061.92 | 18 | 14.90 | 1784 | 478 | 2.62 / 365.00 | 2 | 4 |
5 | 13 | 638.24 | 18 | 14.97 | 1199 | 323 | 2.94 / 365.32 | 2 | 3 |
6 | 13 | 33.56 | 18 | 15.06 | 332 | 90 | 3.03 / 365.41 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 265 | 658 | 3.69 / 366.07 | 2 | 9 |
8 | 14 | 0.12 | 30 | 15.02 | 259 | 117 | 3.81 / 366.19 | 2 | 10 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 30 | 15.00 | 410 | 184 | 0.18 / 358.93 | 2 | 2 |
2 | 7 | 2010.76 | 29 | 14.90 | 2957 | 1278 | 1.46 / 360.21 | 2 | 3 |
3 | 13 | 1618.64 | 18 | 14.86 | 2477 | 663 | 2.12 / 360.87 | 2 | 2 |
4 | 13 | 1197.40 | 18 | 14.89 | 1926 | 516 | 2.64 / 361.39 | 2 | 3 |
5 | 13 | 478.44 | 18 | 14.98 | 945 | 255 | 2.90 / 361.64 | 2 | 3 |
6 | 13 | 37.84 | 18 | 15.06 | 325 | 88 | 2.98 / 361.73 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.03 | 263 | 652 | 3.64 / 362.38 | 2 | 6 |
Average= | 2.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 15.01 | 429 | 193 | 0.19 / 355.36 | 2 | 2 |
2 | 7 | 2005.12 | 29 | 14.92 | 2948 | 1276 | 1.47 / 356.64 | 2 | 3 |
3 | 13 | 1728.12 | 18 | 14.90 | 2606 | 699 | 2.17 / 357.34 | 2 | 4 |
4 | 13 | 1126.32 | 18 | 14.94 | 1827 | 491 | 2.66 / 357.83 | 2 | 3 |
5 | 13 | 537.04 | 18 | 15.00 | 1025 | 277 | 2.94 / 358.11 | 2 | 3 |
6 | 8 | 0.44 | 165 | 15.06 | 257 | 639 | 3.57 / 358.75 | 2 | 7 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 30 | 15.01 | 412 | 186 | 0.19 / 351.68 | 2 | 2 |
2 | 7 | 2011.24 | 29 | 14.93 | 2966 | 1284 | 1.47 / 352.96 | 2 | 3 |
3 | 13 | 1610.60 | 18 | 14.90 | 2465 | 661 | 2.13 / 353.62 | 2 | 2 |
4 | 13 | 1071.04 | 18 | 14.94 | 1758 | 473 | 2.60 / 354.09 | 2 | 3 |
5 | 13 | 510.12 | 18 | 15.00 | 1007 | 272 | 2.88 / 354.37 | 2 | 3 |
6 | 13 | 45.60 | 18 | 15.07 | 339 | 92 | 2.97 / 354.46 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.05 | 287 | 713 | 3.68 / 355.17 | 2 | 5 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 30 | 15.01 | 406 | 183 | 0.18 / 348.22 | 2 | 2 |
2 | 7 | 2006.12 | 29 | 14.92 | 2948 | 1276 | 1.46 / 349.49 | 2 | 3 |
3 | 13 | 1602.24 | 18 | 14.89 | 2452 | 657 | 2.12 / 350.15 | 2 | 4 |
4 | 13 | 1048.04 | 18 | 14.94 | 1720 | 463 | 2.58 / 350.61 | 2 | 3 |
5 | 13 | 471.68 | 18 | 15.01 | 924 | 250 | 2.83 / 350.86 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.05 | 253 | 628 | 3.46 / 351.49 | 2 | 3 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 30 | 15.03 | 406 | 183 | 0.18 / 344.68 | 2 | 2 |
2 | 7 | 2004.64 | 29 | 14.95 | 2954 | 1281 | 1.46 / 345.96 | 2 | 3 |
3 | 13 | 1619.96 | 18 | 14.89 | 2471 | 662 | 2.13 / 346.62 | 2 | 2 |
4 | 13 | 1200.56 | 18 | 14.92 | 1922 | 516 | 2.64 / 347.14 | 2 | 4 |
5 | 13 | 478.48 | 18 | 15.02 | 938 | 254 | 2.90 / 347.39 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.07 | 258 | 642 | 3.54 / 348.04 | 2 | 8 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 30 | 15.03 | 400 | 180 | 0.18 / 341.08 | 2 | 2 |
2 | 7 | 2012.32 | 29 | 14.94 | 2962 | 1283 | 1.46 / 342.36 | 2 | 3 |
3 | 13 | 1745.24 | 18 | 14.89 | 2634 | 706 | 2.17 / 343.07 | 2 | 3 |
4 | 13 | 1057.80 | 18 | 14.94 | 1731 | 466 | 2.64 / 343.54 | 2 | 3 |
5 | 13 | 489.60 | 18 | 15.02 | 953 | 258 | 2.89 / 343.79 | 2 | 3 |
6 | 13 | 20.36 | 18 | 15.09 | 289 | 78 | 2.97 / 343.87 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.07 | 252 | 627 | 3.60 / 344.50 | 2 | 7 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 30 | 15.03 | 425 | 192 | 0.19 / 337.46 | 2 | 2 |
2 | 7 | 2011.20 | 29 | 14.93 | 2961 | 1282 | 1.47 / 338.74 | 2 | 3 |
3 | 13 | 1512.96 | 18 | 14.91 | 2325 | 624 | 2.10 / 339.36 | 2 | 3 |
4 | 13 | 1099.80 | 18 | 14.93 | 1793 | 482 | 2.58 / 339.85 | 2 | 3 |
5 | 13 | 391.40 | 18 | 15.04 | 813 | 220 | 2.80 / 340.07 | 2 | 3 |
6 | 13 | 30.48 | 18 | 15.10 | 308 | 84 | 2.88 / 340.15 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.08 | 255 | 634 | 3.52 / 340.78 | 2 | 5 |
8 | 14 | 0.08 | 30 | 15.05 | 258 | 116 | 3.63 / 340.90 | 2 | 8 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 30 | 15.08 | 414 | 187 | 0.19 / 333.90 | 2 | 2 |
2 | 7 | 1798.08 | 29 | 14.96 | 2696 | 1170 | 1.36 / 335.07 | 2 | 2 |
3 | 13 | 1550.44 | 18 | 14.92 | 2371 | 637 | 1.99 / 335.71 | 2 | 3 |
4 | 13 | 1012.20 | 18 | 14.97 | 1676 | 452 | 2.45 / 336.16 | 2 | 3 |
5 | 13 | 457.84 | 18 | 15.05 | 916 | 248 | 2.69 / 336.41 | 2 | 3 |
6 | 13 | 33.52 | 18 | 15.11 | 319 | 87 | 2.78 / 336.49 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.09 | 263 | 655 | 3.44 / 337.15 | 2 | 7 |
8 | 14 | 0.28 | 30 | 15.07 | 263 | 119 | 3.55 / 337.27 | 2 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 30 | 15.09 | 417 | 189 | 0.19 / 331.01 | 2 | 2 |
2 | 7 | 1286.92 | 29 | 15.14 | 2029 | 891 | 1.08 / 331.90 | 2 | 3 |
3 | 13 | 1229.40 | 18 | 15.08 | 1960 | 532 | 1.61 / 332.43 | 2 | 3 |
4 | 13 | 964.60 | 18 | 15.08 | 1594 | 433 | 2.04 / 332.86 | 2 | 3 |
5 | 13 | 257.84 | 18 | 15.15 | 634 | 173 | 2.22 / 333.04 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.14 | 270 | 674 | 2.89 / 333.71 | 2 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 30 | 15.12 | 421 | 191 | 0.19 / 328.20 | 2 | 2 |
2 | 7 | 1203.48 | 29 | 15.17 | 1911 | 841 | 1.03 / 329.04 | 2 | 2 |
3 | 13 | 1160.32 | 18 | 15.12 | 1860 | 506 | 1.54 / 329.55 | 2 | 4 |
4 | 13 | 919.16 | 18 | 15.11 | 1541 | 419 | 1.96 / 329.96 | 2 | 4 |
5 | 13 | 311.24 | 18 | 15.16 | 707 | 193 | 2.15 / 330.16 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.15 | 265 | 662 | 2.81 / 330.82 | 2 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 30 | 15.11 | 414 | 188 | 0.19 / 325.40 | 2 | 2 |
2 | 10 | 1001.20 | 2 | 15.14 | 1686 | 51 | 0.24 / 325.45 | 2 | 2 |
3 | 3 | 925.20 | -2 | 15.46 | 0 | 0 | 0.05 / 325.45 | 2 | 2 |
4 | 7 | 1198.84 | 29 | 15.17 | 1908 | 839 | 1.08 / 326.29 | 2 | 3 |
5 | 13 | 1157.08 | 18 | 15.12 | 1856 | 505 | 1.58 / 326.80 | 2 | 3 |
6 | 13 | 902.84 | 18 | 15.11 | 1512 | 411 | 1.99 / 327.21 | 2 | 3 |
7 | 13 | 188.84 | 18 | 15.17 | 536 | 146 | 2.14 / 327.36 | 2 | 3 |
8 | 8 | -0.12 | 165 | 15.17 | 260 | 651 | 2.79 / 328.01 | 2 | 5 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 30 | 15.09 | 420 | 190 | 0.19 / 322.59 | 2 | 2 |
2 | 7 | 1204.76 | 29 | 15.17 | 1917 | 843 | 1.03 / 323.44 | 2 | 3 |
3 | 13 | 1163.72 | 18 | 15.12 | 1874 | 510 | 1.54 / 323.95 | 2 | 2 |
4 | 13 | 914.92 | 18 | 15.10 | 1533 | 417 | 1.96 / 324.36 | 2 | 2 |
5 | 13 | 335.48 | 18 | 15.15 | 738 | 201 | 2.16 / 324.57 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.16 | 260 | 650 | 2.81 / 325.22 | 2 | 2 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 15.09 | 423 | 191 | 0.19 / 319.67 | 2 | 3 |
2 | 7 | 1214.80 | 29 | 15.17 | 1927 | 848 | 1.04 / 320.52 | 2 | 3 |
3 | 13 | 1175.44 | 18 | 15.12 | 1885 | 513 | 1.55 / 321.04 | 2 | 3 |
4 | 13 | 931.16 | 18 | 15.10 | 1560 | 424 | 1.98 / 321.46 | 2 | 4 |
5 | 13 | 338.56 | 18 | 15.17 | 747 | 204 | 2.18 / 321.66 | 2 | 2 |
6 | 13 | 39.32 | 18 | 15.18 | 323 | 88 | 2.27 / 321.75 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.16 | 261 | 653 | 2.92 / 322.40 | 2 | 4 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 30 | 15.10 | 417 | 189 | 0.19 / 316.75 | 2 | 2 |
2 | 7 | 1202.76 | 29 | 15.17 | 1919 | 844 | 1.03 / 317.59 | 2 | 3 |
3 | 13 | 1160.60 | 18 | 15.12 | 1877 | 511 | 1.54 / 318.10 | 2 | 4 |
4 | 13 | 1037.92 | 18 | 15.09 | 1705 | 463 | 2.01 / 318.57 | 2 | 3 |
5 | 13 | 151.16 | 18 | 15.18 | 488 | 133 | 2.14 / 318.70 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.16 | 265 | 663 | 2.80 / 319.36 | 2 | 3 |
7 | 14 | 0.16 | 30 | 15.14 | 263 | 119 | 2.92 / 319.48 | 2 | 15 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 15.09 | 416 | 188 | 0.19 / 313.86 | 2 | 2 |
2 | 7 | 1195.72 | 29 | 15.18 | 1902 | 837 | 1.03 / 314.70 | 2 | 3 |
3 | 13 | 1157.72 | 18 | 15.12 | 1854 | 505 | 1.53 / 315.20 | 2 | 3 |
4 | 13 | 1035.60 | 18 | 15.09 | 1696 | 461 | 1.99 / 315.66 | 2 | 3 |
5 | 13 | 411.40 | 18 | 15.14 | 844 | 230 | 2.22 / 315.89 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.16 | 267 | 668 | 2.89 / 316.56 | 2 | 3 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 15.09 | 420 | 190 | 0.19 / 310.92 | 2 | 2 |
2 | 10 | 1001.16 | 2 | 15.14 | 1706 | 52 | 0.24 / 310.97 | 2 | 2 |
3 | 3 | 938.32 | -2 | 15.47 | 0 | 0 | 0.05 / 310.97 | 2 | 2 |
4 | 7 | 1197.36 | 29 | 15.16 | 1894 | 833 | 1.07 / 311.81 | 2 | 2 |
5 | 13 | 1155.76 | 18 | 15.10 | 1845 | 501 | 1.58 / 312.31 | 2 | 2 |
6 | 13 | 1036.44 | 18 | 15.08 | 1693 | 460 | 2.04 / 312.77 | 2 | 3 |
7 | 13 | 243.12 | 18 | 15.18 | 607 | 166 | 2.20 / 312.93 | 2 | 2 |
8 | 13 | 40.44 | 18 | 15.19 | 324 | 89 | 2.29 / 313.02 | 2 | 3 |
9 | 8 | 0.20 | 165 | 15.17 | 259 | 648 | 2.94 / 313.67 | 2 | 12 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 30 | 15.11 | 400 | 181 | 0.18 / 308.07 | 2 | 2 |
2 | 7 | 1212.12 | 29 | 15.17 | 1908 | 839 | 1.02 / 308.91 | 2 | 3 |
3 | 13 | 1181.72 | 18 | 15.11 | 1897 | 516 | 1.54 / 309.42 | 2 | 3 |
4 | 13 | 922.72 | 18 | 15.12 | 1536 | 418 | 1.95 / 309.84 | 2 | 3 |
5 | 13 | 220.72 | 18 | 15.18 | 575 | 157 | 2.11 / 310.00 | 2 | 3 |
6 | 13 | 64.04 | 18 | 15.17 | 355 | 97 | 2.21 / 310.09 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.15 | 256 | 640 | 2.85 / 310.73 | 2 | 16 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 30 | 15.12 | 428 | 194 | 0.19 / 305.24 | 2 | 2 |
2 | 7 | 1205.84 | 29 | 15.17 | 1903 | 837 | 1.03 / 306.07 | 2 | 3 |
3 | 13 | 1166.84 | 18 | 15.11 | 1867 | 508 | 1.54 / 306.58 | 2 | 3 |
4 | 13 | 921.88 | 18 | 15.11 | 1550 | 422 | 1.96 / 307.00 | 2 | 3 |
5 | 13 | 176.80 | 18 | 15.19 | 522 | 143 | 2.10 / 307.15 | 2 | 2 |
6 | 13 | 35.28 | 18 | 15.19 | 323 | 88 | 2.19 / 307.23 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.17 | 260 | 651 | 2.84 / 307.88 | 2 | 8 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 30 | 15.08 | 409 | 185 | 0.19 / 302.40 | 2 | 2 |
2 | 7 | 1199.76 | 29 | 15.19 | 1917 | 844 | 1.03 / 303.24 | 2 | 4 |
3 | 13 | 1156.80 | 18 | 15.13 | 1853 | 505 | 1.53 / 303.74 | 2 | 3 |
4 | 13 | 923.64 | 18 | 15.12 | 1540 | 419 | 1.95 / 304.16 | 2 | 3 |
5 | 13 | 310.56 | 18 | 15.18 | 712 | 195 | 2.15 / 304.36 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.17 | 273 | 683 | 2.83 / 305.04 | 2 | 6 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 30 | 15.12 | 422 | 191 | 0.19 / 299.35 | 2 | 2 |
2 | 7 | 1200.52 | 29 | 15.16 | 1904 | 837 | 1.03 / 300.19 | 2 | 3 |
3 | 13 | 1166.88 | 18 | 15.08 | 1866 | 507 | 1.54 / 300.69 | 2 | 3 |
4 | 13 | 943.16 | 18 | 15.11 | 1580 | 430 | 1.96 / 301.12 | 2 | 3 |
5 | 13 | 384.64 | 18 | 15.14 | 813 | 222 | 2.19 / 301.34 | 2 | 3 |
6 | 13 | 34.16 | 18 | 15.18 | 321 | 88 | 2.27 / 301.43 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.16 | 264 | 660 | 2.93 / 302.09 | 2 | 6 |
8 | 14 | 0.12 | 30 | 15.13 | 263 | 119 | 3.05 / 302.21 | 3 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 30 | 15.10 | 426 | 193 | 0.19 / 296.29 | 2 | 2 |
2 | 7 | 1193.76 | 29 | 15.18 | 1900 | 836 | 1.03 / 297.13 | 2 | 3 |
3 | 13 | 1150.92 | 18 | 15.13 | 1888 | 514 | 1.54 / 297.64 | 2 | 3 |
4 | 13 | 1026.20 | 18 | 15.11 | 1736 | 472 | 2.02 / 298.11 | 2 | 3 |
5 | 13 | 408.52 | 18 | 15.16 | 905 | 247 | 2.26 / 298.36 | 2 | 2 |
6 | 13 | 40.48 | 18 | 15.20 | 373 | 102 | 2.36 / 298.46 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.17 | 278 | 696 | 3.06 / 299.16 | 2 | 4 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 30 | 15.13 | 406 | 184 | 0.18 / 293.36 | 2 | 2 |
2 | 7 | 1198.72 | 29 | 15.18 | 1909 | 840 | 1.02 / 294.20 | 2 | 3 |
3 | 13 | 1156.84 | 18 | 15.11 | 1851 | 503 | 1.53 / 294.71 | 2 | 3 |
4 | 13 | 1034.44 | 18 | 15.08 | 1688 | 458 | 1.99 / 295.17 | 2 | 3 |
5 | 13 | 293.24 | 18 | 15.17 | 686 | 187 | 2.17 / 295.35 | 2 | 3 |
6 | 13 | 21.64 | 18 | 15.20 | 301 | 82 | 2.26 / 295.44 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.16 | 264 | 660 | 2.92 / 296.10 | 2 | 5 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 30 | 15.11 | 423 | 192 | 0.19 / 290.51 | 2 | 2 |
2 | 7 | 1202.92 | 29 | 15.19 | 1917 | 844 | 1.04 / 291.35 | 2 | 2 |
3 | 13 | 1160.08 | 18 | 15.14 | 1867 | 509 | 1.54 / 291.86 | 2 | 3 |
4 | 13 | 909.52 | 18 | 15.13 | 1530 | 417 | 1.96 / 292.28 | 2 | 3 |
5 | 13 | 204.60 | 18 | 15.20 | 563 | 154 | 2.12 / 292.43 | 2 | 2 |
6 | 13 | 16.20 | 18 | 15.21 | 295 | 81 | 2.20 / 292.51 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.18 | 267 | 669 | 2.87 / 293.18 | 2 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 29 | 15.12 | 484 | 212 | 0.21 / 287.49 | 2 | 2 |
2 | 3 | 1038.40 | 1 | 15.20 | 1775 | 27 | 0.24 / 287.52 | 2 | 2 |
3 | 7 | 1208.76 | 29 | 15.16 | 1919 | 844 | 1.08 / 288.36 | 2 | 2 |
4 | 13 | 1161.20 | 18 | 15.11 | 1864 | 507 | 1.59 / 288.87 | 2 | 3 |
5 | 13 | 1037.24 | 18 | 15.09 | 1701 | 462 | 2.05 / 289.33 | 2 | 3 |
6 | 13 | 250.04 | 18 | 15.18 | 634 | 173 | 2.23 / 289.51 | 2 | 3 |
7 | 13 | 37.80 | 18 | 15.19 | 368 | 101 | 2.33 / 289.61 | 2 | 2 |
8 | 8 | 0.24 | 165 | 15.17 | 283 | 708 | 3.03 / 290.31 | 2 | 6 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 30 | 15.12 | 422 | 191 | 0.19 / 284.54 | 2 | 2 |
2 | 3 | 1019.60 | 1 | 15.22 | 1716 | 26 | 0.22 / 284.56 | 2 | 2 |
3 | 7 | 1193.16 | 29 | 15.21 | 1900 | 838 | 1.06 / 285.40 | 2 | 3 |
4 | 13 | 1154.76 | 18 | 15.13 | 1849 | 504 | 1.56 / 285.90 | 2 | 3 |
5 | 13 | 910.92 | 18 | 15.14 | 1521 | 415 | 1.97 / 286.32 | 2 | 3 |
6 | 13 | 312.00 | 18 | 15.20 | 704 | 193 | 2.17 / 286.51 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.18 | 307 | 769 | 2.94 / 287.28 | 2 | 5 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 30 | 15.12 | 410 | 186 | 0.19 / 281.61 | 2 | 2 |
2 | 7 | 1227.76 | 29 | 15.18 | 1934 | 851 | 1.04 / 282.46 | 2 | 3 |
3 | 13 | 1185.88 | 18 | 15.12 | 1891 | 515 | 1.55 / 282.98 | 2 | 3 |
4 | 13 | 909.88 | 18 | 15.13 | 1525 | 415 | 1.97 / 283.39 | 2 | 3 |
5 | 13 | 333.92 | 18 | 15.18 | 741 | 202 | 2.17 / 283.59 | 2 | 2 |
6 | 13 | 67.24 | 18 | 15.21 | 366 | 100 | 2.27 / 283.69 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.18 | 260 | 651 | 2.92 / 284.35 | 2 | 8 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 29 | 15.11 | 407 | 178 | 0.18 / 278.74 | 2 | 2 |
2 | 3 | 1017.24 | 1 | 15.23 | 1736 | 26 | 0.20 / 278.77 | 2 | 2 |
3 | 7 | 1223.00 | 29 | 15.19 | 1931 | 851 | 1.06 / 279.62 | 2 | 2 |
4 | 13 | 1175.16 | 18 | 15.13 | 1874 | 510 | 1.57 / 280.13 | 2 | 3 |
5 | 13 | 920.08 | 18 | 15.11 | 1533 | 417 | 1.98 / 280.54 | 2 | 3 |
6 | 13 | 197.48 | 18 | 15.19 | 542 | 148 | 2.13 / 280.69 | 2 | 2 |
7 | 13 | 39.20 | 18 | 15.20 | 323 | 88 | 2.22 / 280.78 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.18 | 257 | 644 | 2.86 / 281.42 | 2 | 10 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 15.15 | 413 | 181 | 0.18 / 275.89 | 2 | 2 |
2 | 7 | 1258.56 | 29 | 15.18 | 1973 | 869 | 1.05 / 276.76 | 2 | 3 |
3 | 13 | 1199.40 | 18 | 15.13 | 1911 | 520 | 1.57 / 277.28 | 2 | 3 |
4 | 13 | 959.16 | 18 | 15.12 | 1593 | 434 | 2.00 / 277.71 | 2 | 3 |
5 | 13 | 356.24 | 18 | 15.17 | 768 | 210 | 2.21 / 277.92 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.19 | 256 | 642 | 2.86 / 278.56 | 2 | 7 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 29 | 15.14 | 407 | 179 | 0.18 / 273.08 | 2 | 2 |
2 | 7 | 1253.80 | 29 | 15.17 | 1984 | 873 | 1.05 / 273.96 | 2 | 3 |
3 | 13 | 1198.68 | 18 | 15.11 | 1902 | 517 | 1.57 / 274.47 | 2 | 3 |
4 | 13 | 942.16 | 18 | 15.12 | 1563 | 425 | 1.99 / 274.90 | 2 | 3 |
5 | 13 | 203.04 | 18 | 15.20 | 555 | 152 | 2.15 / 275.05 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.20 | 261 | 655 | 2.80 / 275.71 | 2 | 4 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 29 | 15.15 | 425 | 187 | 0.19 / 270.39 | 2 | 2 |
2 | 7 | 1168.16 | 29 | 15.19 | 1862 | 820 | 1.01 / 271.21 | 2 | 4 |
3 | 13 | 1129.96 | 18 | 15.15 | 1814 | 495 | 1.50 / 271.70 | 2 | 3 |
4 | 13 | 887.20 | 18 | 15.14 | 1489 | 406 | 1.91 / 272.11 | 2 | 3 |
5 | 13 | 173.72 | 18 | 15.21 | 515 | 141 | 2.05 / 272.25 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.20 | 262 | 657 | 2.71 / 272.91 | 2 | 4 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 29 | 15.15 | 420 | 185 | 0.18 / 267.65 | 2 | 2 |
2 | 7 | 1142.16 | 29 | 15.21 | 1822 | 804 | 0.99 / 268.46 | 2 | 2 |
3 | 13 | 1111.72 | 18 | 15.16 | 1787 | 488 | 1.48 / 268.94 | 2 | 3 |
4 | 13 | 985.92 | 18 | 15.13 | 1620 | 441 | 1.92 / 269.38 | 2 | 3 |
5 | 13 | 224.24 | 18 | 15.22 | 585 | 160 | 2.08 / 269.54 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.22 | 261 | 655 | 2.73 / 270.20 | 2 | 5 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 29 | 15.17 | 408 | 179 | 0.18 / 264.92 | 2 | 2 |
2 | 7 | 1161.96 | 29 | 15.21 | 1849 | 816 | 1.00 / 265.74 | 2 | 2 |
3 | 13 | 1126.88 | 18 | 15.16 | 1809 | 494 | 1.49 / 266.23 | 2 | 3 |
4 | 13 | 869.36 | 18 | 15.15 | 1465 | 400 | 1.89 / 266.63 | 2 | 3 |
5 | 13 | 280.48 | 18 | 15.20 | 661 | 181 | 2.07 / 266.81 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.21 | 261 | 655 | 2.72 / 267.47 | 2 | 3 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 29 | 15.17 | 412 | 181 | 0.18 / 262.24 | 2 | 2 |
2 | 7 | 1118.00 | 29 | 15.22 | 1786 | 788 | 0.97 / 263.03 | 2 | 4 |
3 | 13 | 1096.88 | 18 | 15.17 | 1769 | 483 | 1.45 / 263.51 | 2 | 3 |
4 | 13 | 843.12 | 18 | 15.17 | 1431 | 391 | 1.84 / 263.91 | 2 | 3 |
5 | 13 | 274.88 | 18 | 15.20 | 655 | 179 | 2.02 / 264.08 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.23 | 262 | 658 | 2.68 / 264.74 | 2 | 5 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 29 | 15.18 | 419 | 184 | 0.18 / 259.63 | 2 | 2 |
2 | 7 | 1106.28 | 29 | 15.23 | 1775 | 784 | 0.97 / 260.41 | 2 | 3 |
3 | 13 | 1100.56 | 18 | 15.17 | 1770 | 483 | 1.45 / 260.89 | 2 | 3 |
4 | 13 | 856.72 | 18 | 15.17 | 1446 | 395 | 1.85 / 261.29 | 2 | 2 |
5 | 13 | 136.28 | 18 | 15.24 | 459 | 126 | 1.97 / 261.41 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.23 | 258 | 648 | 2.62 / 262.06 | 2 | 4 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 15.18 | 419 | 184 | 0.18 / 256.96 | 2 | 2 |
2 | 7 | 1046.40 | 29 | 15.26 | 1702 | 753 | 0.94 / 257.71 | 2 | 2 |
3 | 13 | 1045.80 | 18 | 15.20 | 1704 | 466 | 1.40 / 258.18 | 2 | 2 |
4 | 13 | 920.16 | 18 | 15.17 | 1533 | 419 | 1.82 / 258.60 | 2 | 3 |
5 | 13 | 308.40 | 18 | 15.24 | 699 | 192 | 2.01 / 258.79 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.25 | 260 | 654 | 2.67 / 259.44 | 2 | 6 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 29 | 15.17 | 408 | 179 | 0.18 / 254.31 | 2 | 2 |
2 | 7 | 1043.84 | 29 | 15.25 | 1693 | 749 | 0.93 / 255.06 | 2 | 3 |
3 | 13 | 1043.48 | 18 | 15.18 | 1704 | 466 | 1.39 / 255.53 | 2 | 3 |
4 | 13 | 917.80 | 18 | 15.17 | 1532 | 418 | 1.81 / 255.95 | 2 | 3 |
5 | 13 | 203.16 | 18 | 15.25 | 556 | 153 | 1.96 / 256.10 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.23 | 268 | 673 | 2.64 / 256.77 | 2 | 4 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 29 | 15.18 | 402 | 177 | 0.18 / 251.58 | 2 | 2 |
2 | 7 | 1031.96 | 29 | 15.26 | 1679 | 743 | 0.92 / 252.33 | 2 | 3 |
3 | 13 | 1031.32 | 18 | 15.19 | 1684 | 460 | 1.38 / 252.79 | 2 | 3 |
4 | 13 | 910.40 | 18 | 15.17 | 1519 | 415 | 1.80 / 253.20 | 2 | 3 |
5 | 13 | 177.48 | 18 | 15.25 | 521 | 143 | 1.94 / 253.34 | 2 | 2 |
6 | 8 | -0.24 | 165 | 15.24 | 267 | 671 | 2.61 / 254.02 | 2 | 3 |
7 | 14 | -0.24 | 30 | 15.21 | 262 | 120 | 2.73 / 254.13 | 2 | 13 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 29 | 15.19 | 417 | 184 | 0.18 / 248.91 | 2 | 2 |
2 | 7 | 1076.28 | 29 | 15.24 | 1736 | 767 | 0.95 / 249.68 | 2 | 2 |
3 | 13 | 1075.00 | 18 | 15.18 | 1737 | 475 | 1.43 / 250.16 | 2 | 3 |
4 | 13 | 951.64 | 18 | 15.16 | 1577 | 430 | 1.86 / 250.59 | 2 | 3 |
5 | 13 | 230.56 | 18 | 15.22 | 594 | 163 | 2.02 / 250.75 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.23 | 261 | 656 | 2.67 / 251.41 | 2 | 7 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 29 | 15.19 | 411 | 181 | 0.18 / 246.23 | 2 | 2 |
2 | 7 | 1042.24 | 29 | 15.25 | 1699 | 751 | 0.93 / 246.98 | 2 | 3 |
3 | 13 | 1042.12 | 18 | 15.21 | 1700 | 465 | 1.40 / 247.45 | 2 | 4 |
4 | 13 | 923.36 | 18 | 15.17 | 1535 | 419 | 1.82 / 247.87 | 2 | 3 |
5 | 13 | 323.80 | 18 | 15.23 | 729 | 200 | 2.02 / 248.07 | 2 | 3 |
6 | 8 | 0.40 | 165 | 15.24 | 264 | 664 | 2.68 / 248.73 | 2 | 6 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 29 | 15.17 | 418 | 184 | 0.18 / 243.64 | 2 | 2 |
2 | 7 | 1042.32 | 29 | 15.27 | 1693 | 750 | 0.93 / 244.39 | 2 | 3 |
3 | 13 | 1041.60 | 18 | 15.19 | 1696 | 464 | 1.40 / 244.85 | 2 | 3 |
4 | 13 | 920.80 | 18 | 15.18 | 1536 | 420 | 1.82 / 245.27 | 2 | 3 |
5 | 13 | 110.04 | 18 | 15.25 | 427 | 117 | 1.93 / 245.39 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.24 | 264 | 664 | 2.60 / 246.05 | 2 | 7 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 29 | 15.18 | 416 | 183 | 0.18 / 240.94 | 2 | 2 |
2 | 7 | 1036.16 | 29 | 15.26 | 1691 | 748 | 0.93 / 241.69 | 2 | 2 |
3 | 13 | 1035.60 | 18 | 15.19 | 1688 | 462 | 1.39 / 242.15 | 2 | 3 |
4 | 13 | 915.60 | 18 | 15.17 | 1520 | 415 | 1.81 / 242.57 | 2 | 3 |
5 | 13 | 94.64 | 18 | 15.25 | 405 | 111 | 1.92 / 242.68 | 2 | 5 |
6 | 8 | 0.00 | 165 | 15.24 | 261 | 656 | 2.58 / 243.33 | 2 | 9 |
7 | 14 | 0.00 | 30 | 15.21 | 262 | 120 | 2.70 / 243.45 | 2 | 4 |
Average= | 2.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 29 | 15.18 | 426 | 188 | 0.19 / 238.33 | 2 | 2 |
2 | 7 | 1041.32 | 29 | 15.24 | 1681 | 743 | 0.93 / 239.07 | 2 | 2 |
3 | 13 | 1040.60 | 18 | 15.19 | 1685 | 461 | 1.39 / 239.53 | 2 | 3 |
4 | 13 | 920.08 | 18 | 15.18 | 1535 | 419 | 1.81 / 239.95 | 2 | 3 |
5 | 13 | 200.36 | 18 | 15.24 | 552 | 151 | 1.96 / 240.10 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.23 | 261 | 656 | 2.62 / 240.76 | 2 | 7 |
Average= | 2.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 29 | 15.18 | 420 | 185 | 0.18 / 235.65 | 2 | 2 |
2 | 7 | 1066.20 | 29 | 15.26 | 1721 | 762 | 0.95 / 236.41 | 2 | 3 |
3 | 13 | 1065.76 | 18 | 15.19 | 1718 | 470 | 1.42 / 236.88 | 2 | 2 |
4 | 13 | 947.28 | 18 | 15.17 | 1571 | 429 | 1.85 / 237.31 | 2 | 3 |
5 | 13 | 209.36 | 18 | 15.25 | 567 | 156 | 2.00 / 237.47 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.24 | 268 | 674 | 2.67 / 238.14 | 2 | 3 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 29 | 15.18 | 412 | 181 | 0.18 / 232.84 | 2 | 2 |
2 | 7 | 1085.32 | 29 | 15.25 | 1752 | 775 | 0.96 / 233.61 | 2 | 3 |
3 | 13 | 1084.92 | 18 | 15.19 | 1754 | 480 | 1.44 / 234.09 | 2 | 3 |
4 | 13 | 960.28 | 18 | 15.16 | 1590 | 434 | 1.87 / 234.52 | 2 | 3 |
5 | 13 | 225.72 | 18 | 15.23 | 586 | 161 | 2.03 / 234.69 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.23 | 262 | 658 | 2.69 / 235.34 | 2 | 4 |
7 | 14 | 0.04 | 30 | 15.21 | 265 | 121 | 2.81 / 235.46 | 2 | 15 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 29 | 15.16 | 422 | 186 | 0.19 / 229.94 | 2 | 2 |
2 | 7 | 1136.76 | 29 | 15.23 | 1819 | 803 | 0.99 / 230.74 | 2 | 4 |
3 | 13 | 1101.92 | 18 | 15.17 | 1775 | 485 | 1.47 / 231.23 | 2 | 3 |
4 | 13 | 869.40 | 18 | 15.16 | 1467 | 400 | 1.87 / 231.63 | 2 | 3 |
5 | 13 | 411.20 | 18 | 15.21 | 849 | 232 | 2.11 / 231.86 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.23 | 267 | 671 | 2.78 / 232.53 | 2 | 3 |
7 | 14 | 0.00 | 30 | 15.21 | 267 | 122 | 2.90 / 232.65 | 2 | 11 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 29 | 15.18 | 418 | 184 | 0.18 / 227.20 | 2 | 2 |
2 | 7 | 1145.84 | 29 | 15.24 | 1838 | 812 | 1.00 / 228.01 | 2 | 2 |
3 | 13 | 1143.32 | 18 | 15.14 | 1827 | 498 | 1.49 / 228.51 | 2 | 4 |
4 | 13 | 879.96 | 18 | 15.16 | 1486 | 405 | 1.90 / 228.91 | 2 | 3 |
5 | 13 | 289.04 | 18 | 15.22 | 678 | 186 | 2.09 / 229.10 | 2 | 2 |
6 | 8 | -0.20 | 165 | 15.23 | 262 | 658 | 2.74 / 229.76 | 2 | 5 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 29 | 15.18 | 424 | 187 | 0.19 / 224.42 | 2 | 2 |
2 | 7 | 1166.80 | 29 | 15.21 | 1858 | 820 | 1.01 / 225.24 | 2 | 3 |
3 | 13 | 1127.16 | 18 | 15.18 | 1815 | 496 | 1.50 / 225.73 | 2 | 3 |
4 | 13 | 1000.36 | 18 | 15.15 | 1645 | 449 | 1.95 / 226.18 | 2 | 3 |
5 | 13 | 254.80 | 18 | 15.23 | 630 | 173 | 2.12 / 226.36 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.23 | 261 | 656 | 2.78 / 227.01 | 2 | 4 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 29 | 15.15 | 408 | 179 | 0.18 / 221.56 | 2 | 2 |
2 | 7 | 1235.48 | 29 | 15.19 | 1960 | 863 | 1.04 / 222.42 | 2 | 3 |
3 | 13 | 1180.48 | 18 | 15.15 | 1887 | 515 | 1.56 / 222.94 | 2 | 3 |
4 | 13 | 961.04 | 18 | 15.13 | 1598 | 435 | 1.99 / 223.37 | 2 | 3 |
5 | 13 | 358.68 | 18 | 15.20 | 770 | 211 | 2.20 / 223.58 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.23 | 258 | 648 | 2.85 / 224.23 | 2 | 3 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 29 | 15.16 | 418 | 184 | 0.18 / 218.51 | 2 | 2 |
2 | 7 | 1429.04 | 29 | 15.14 | 2215 | 973 | 1.16 / 219.48 | 2 | 2 |
3 | 13 | 1340.36 | 18 | 15.10 | 2109 | 573 | 1.73 / 220.05 | 2 | 3 |
4 | 13 | 1057.92 | 18 | 15.09 | 1735 | 471 | 2.20 / 220.53 | 2 | 3 |
5 | 13 | 329.60 | 18 | 15.20 | 733 | 201 | 2.40 / 220.73 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.22 | 261 | 655 | 3.06 / 221.38 | 2 | 4 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 29 | 15.15 | 407 | 179 | 0.18 / 215.47 | 2 | 2 |
2 | 7 | 1476.68 | 29 | 15.12 | 2283 | 1001 | 1.18 / 216.47 | 2 | 3 |
3 | 13 | 1384.84 | 18 | 15.08 | 2167 | 588 | 1.77 / 217.06 | 2 | 3 |
4 | 13 | 965.32 | 18 | 15.09 | 1609 | 437 | 2.21 / 217.50 | 2 | 3 |
5 | 13 | 227.72 | 18 | 15.21 | 594 | 163 | 2.37 / 217.66 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.21 | 264 | 663 | 3.03 / 218.32 | 2 | 4 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 29 | 15.16 | 413 | 182 | 0.18 / 212.05 | 2 | 2 |
2 | 7 | 1700.40 | 29 | 15.03 | 2565 | 1118 | 1.30 / 213.17 | 2 | 3 |
3 | 13 | 1576.20 | 18 | 14.98 | 2411 | 650 | 1.95 / 213.82 | 2 | 4 |
4 | 13 | 1139.36 | 18 | 15.01 | 1836 | 496 | 2.45 / 214.31 | 2 | 3 |
5 | 13 | 377.12 | 18 | 15.14 | 801 | 218 | 2.66 / 214.53 | 2 | 2 |
6 | 8 | 0.48 | 165 | 15.17 | 258 | 646 | 3.31 / 215.18 | 2 | 7 |
7 | 14 | 0.48 | 30 | 15.16 | 259 | 118 | 3.43 / 215.29 | 2 | 7 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 29 | 15.18 | 417 | 184 | 0.18 / 208.95 | 2 | 2 |
2 | 7 | 1488.08 | 29 | 15.14 | 2296 | 1008 | 1.19 / 209.96 | 2 | 3 |
3 | 13 | 1392.68 | 18 | 15.08 | 2175 | 590 | 1.78 / 210.55 | 2 | 3 |
4 | 13 | 983.72 | 18 | 15.10 | 1627 | 442 | 2.22 / 210.99 | 2 | 3 |
5 | 13 | 393.00 | 18 | 15.19 | 824 | 225 | 2.45 / 211.22 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 259 | 650 | 3.10 / 211.87 | 2 | 7 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 29 | 15.19 | 420 | 185 | 0.19 / 205.98 | 2 | 2 |
2 | 7 | 1400.72 | 29 | 15.14 | 2182 | 958 | 1.14 / 206.93 | 2 | 3 |
3 | 13 | 1323.52 | 18 | 15.10 | 2078 | 565 | 1.71 / 207.50 | 2 | 2 |
4 | 13 | 919.72 | 18 | 15.11 | 1541 | 419 | 2.13 / 207.92 | 2 | 3 |
5 | 13 | 302.64 | 18 | 15.21 | 698 | 191 | 2.32 / 208.11 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.23 | 262 | 658 | 2.98 / 208.77 | 2 | 6 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 29 | 15.19 | 408 | 180 | 0.18 / 203.19 | 2 | 2 |
2 | 7 | 1207.68 | 29 | 15.22 | 1912 | 844 | 1.02 / 204.04 | 2 | 2 |
3 | 13 | 1159.00 | 18 | 15.16 | 1856 | 506 | 1.53 / 204.54 | 2 | 3 |
4 | 13 | 1035.28 | 18 | 15.14 | 1708 | 465 | 2.00 / 205.01 | 2 | 3 |
5 | 13 | 163.16 | 18 | 15.27 | 493 | 136 | 2.13 / 205.14 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.26 | 257 | 647 | 2.78 / 205.79 | 2 | 4 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 29 | 15.18 | 415 | 183 | 0.18 / 200.44 | 2 | 2 |
2 | 7 | 1169.56 | 29 | 15.25 | 1868 | 826 | 1.01 / 201.27 | 2 | 3 |
3 | 13 | 1123.44 | 18 | 15.18 | 1813 | 495 | 1.50 / 201.76 | 2 | 3 |
4 | 13 | 863.60 | 18 | 15.18 | 1466 | 401 | 1.90 / 202.16 | 2 | 3 |
5 | 13 | 322.32 | 18 | 15.24 | 724 | 199 | 2.10 / 202.36 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.24 | 258 | 649 | 2.75 / 203.01 | 2 | 11 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 29 | 15.19 | 414 | 182 | 0.18 / 197.72 | 2 | 2 |
2 | 7 | 1200.44 | 29 | 15.22 | 1901 | 839 | 1.02 / 198.56 | 2 | 3 |
3 | 13 | 1150.20 | 18 | 15.18 | 1841 | 503 | 1.52 / 199.06 | 2 | 3 |
4 | 13 | 904.84 | 18 | 15.16 | 1516 | 414 | 1.94 / 199.47 | 2 | 3 |
5 | 13 | 166.36 | 18 | 15.25 | 501 | 138 | 2.08 / 199.61 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.25 | 258 | 649 | 2.72 / 200.26 | 2 | 7 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 29 | 15.19 | 398 | 175 | 0.18 / 195.00 | 2 | 2 |
2 | 7 | 1126.20 | 29 | 15.26 | 1807 | 800 | 0.97 / 195.80 | 2 | 2 |
3 | 13 | 1092.56 | 18 | 15.21 | 1767 | 484 | 1.46 / 196.28 | 2 | 3 |
4 | 13 | 966.88 | 18 | 15.18 | 1604 | 438 | 1.90 / 196.72 | 2 | 3 |
5 | 13 | 224.04 | 18 | 15.26 | 584 | 160 | 2.06 / 196.88 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.25 | 260 | 654 | 2.71 / 197.54 | 2 | 5 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 29 | 15.21 | 407 | 180 | 0.18 / 192.23 | 2 | 2 |
2 | 7 | 1105.00 | 29 | 15.27 | 1775 | 786 | 0.97 / 193.02 | 2 | 2 |
3 | 13 | 1085.96 | 18 | 15.23 | 1752 | 480 | 1.45 / 193.50 | 2 | 3 |
4 | 13 | 961.28 | 18 | 15.17 | 1585 | 433 | 1.88 / 193.93 | 2 | 3 |
5 | 13 | 230.04 | 18 | 15.28 | 584 | 161 | 2.04 / 194.09 | 2 | 2 |
6 | 13 | 13.08 | 18 | 15.29 | 285 | 78 | 2.12 / 194.17 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.25 | 259 | 652 | 2.77 / 194.82 | 2 | 10 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 29 | 15.20 | 405 | 179 | 0.18 / 189.40 | 2 | 2 |
2 | 7 | 1127.72 | 29 | 15.26 | 1807 | 800 | 0.98 / 190.20 | 2 | 3 |
3 | 13 | 1127.08 | 18 | 15.18 | 1808 | 494 | 1.47 / 190.70 | 2 | 2 |
4 | 13 | 1011.44 | 18 | 15.14 | 1649 | 449 | 1.92 / 191.15 | 2 | 3 |
5 | 13 | 255.24 | 18 | 15.26 | 626 | 172 | 2.09 / 191.32 | 2 | 3 |
6 | 13 | 20.76 | 18 | 15.28 | 295 | 81 | 2.17 / 191.40 | 2 | 2 |
7 | 8 | 0.40 | 165 | 15.25 | 260 | 654 | 2.83 / 192.05 | 2 | 6 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 29 | 15.23 | 410 | 181 | 0.18 / 186.64 | 2 | 2 |
2 | 7 | 1093.56 | 29 | 15.27 | 1771 | 784 | 0.97 / 187.43 | 2 | 2 |
3 | 13 | 1092.96 | 18 | 15.20 | 1766 | 483 | 1.45 / 187.91 | 2 | 3 |
4 | 13 | 971.40 | 18 | 15.17 | 1602 | 437 | 1.89 / 188.35 | 2 | 3 |
5 | 13 | 203.32 | 18 | 15.28 | 549 | 151 | 2.04 / 188.50 | 2 | 2 |
6 | 13 | 16.72 | 18 | 15.28 | 290 | 80 | 2.12 / 188.58 | 2 | 5 |
7 | 8 | 0.08 | 165 | 15.25 | 257 | 647 | 2.76 / 189.23 | 2 | 12 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 15.16 | 407 | 179 | 0.18 / 184.02 | 2 | 2 |
2 | 7 | 1119.48 | 29 | 15.28 | 1798 | 797 | 0.98 / 184.81 | 2 | 2 |
3 | 13 | 1091.32 | 18 | 15.22 | 1771 | 485 | 1.46 / 185.30 | 2 | 3 |
4 | 13 | 839.76 | 18 | 15.21 | 1429 | 391 | 1.85 / 185.69 | 2 | 3 |
5 | 13 | 135.72 | 18 | 15.30 | 456 | 126 | 1.98 / 185.81 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.28 | 257 | 648 | 2.63 / 186.46 | 2 | 3 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 29 | 15.19 | 415 | 183 | 0.18 / 180.51 | 2 | 2 |
2 | 7 | 1797.60 | 29 | 15.04 | 2682 | 1170 | 1.35 / 181.68 | 2 | 3 |
3 | 13 | 1672.80 | 18 | 14.99 | 2544 | 686 | 2.04 / 182.37 | 2 | 4 |
4 | 13 | 1087.64 | 18 | 15.02 | 1783 | 482 | 2.52 / 182.85 | 2 | 4 |
5 | 13 | 471.44 | 18 | 15.16 | 926 | 253 | 2.77 / 183.10 | 2 | 3 |
6 | 13 | 13.60 | 18 | 15.22 | 291 | 80 | 2.85 / 183.18 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.21 | 260 | 653 | 3.51 / 183.84 | 2 | 14 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 29 | 15.19 | 417 | 184 | 0.18 / 177.38 | 2 | 3 |
2 | 7 | 1516.28 | 29 | 15.12 | 2330 | 1022 | 1.21 / 178.40 | 2 | 3 |
3 | 13 | 1410.00 | 18 | 15.08 | 2199 | 597 | 1.80 / 179.00 | 2 | 3 |
4 | 13 | 983.52 | 18 | 15.12 | 1635 | 445 | 2.25 / 179.44 | 2 | 3 |
5 | 13 | 389.04 | 18 | 15.20 | 824 | 225 | 2.47 / 179.67 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.24 | 263 | 661 | 3.13 / 180.33 | 2 | 3 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 15.19 | 416 | 183 | 0.18 / 174.40 | 2 | 2 |
2 | 3 | 1021.92 | 1 | 15.28 | 1742 | 27 | 0.21 / 174.42 | 2 | 2 |
3 | 7 | 1384.12 | 29 | 15.16 | 2152 | 946 | 1.16 / 175.37 | 2 | 3 |
4 | 13 | 1298.96 | 18 | 15.11 | 2047 | 557 | 1.71 / 175.93 | 2 | 3 |
5 | 13 | 897.96 | 18 | 15.12 | 1513 | 412 | 2.12 / 176.34 | 2 | 3 |
6 | 13 | 294.52 | 18 | 15.22 | 685 | 188 | 2.31 / 176.53 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.24 | 266 | 669 | 2.98 / 177.20 | 2 | 12 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 29 | 15.23 | 414 | 183 | 0.18 / 171.41 | 2 | 2 |
2 | 7 | 1444.00 | 29 | 15.14 | 2234 | 981 | 1.16 / 172.39 | 2 | 3 |
3 | 13 | 1359.48 | 18 | 15.08 | 2132 | 579 | 1.74 / 172.97 | 2 | 3 |
4 | 13 | 946.68 | 18 | 15.13 | 1581 | 431 | 2.17 / 173.40 | 2 | 3 |
5 | 13 | 201.92 | 18 | 15.24 | 554 | 152 | 2.32 / 173.55 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.24 | 265 | 666 | 2.99 / 174.22 | 2 | 3 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 29 | 15.21 | 419 | 185 | 0.18 / 168.69 | 2 | 2 |
2 | 7 | 1117.48 | 29 | 15.26 | 1801 | 797 | 0.98 / 169.49 | 2 | 3 |
3 | 13 | 1084.16 | 18 | 15.23 | 1760 | 482 | 1.46 / 169.97 | 2 | 2 |
4 | 13 | 957.88 | 18 | 15.20 | 1595 | 436 | 1.90 / 170.41 | 2 | 3 |
5 | 13 | 196.36 | 18 | 15.29 | 550 | 151 | 2.05 / 170.56 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.29 | 263 | 664 | 2.72 / 171.22 | 2 | 8 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 29 | 15.23 | 419 | 185 | 0.19 / 165.74 | 2 | 2 |
2 | 7 | 1364.56 | 29 | 15.18 | 2131 | 938 | 1.12 / 166.68 | 2 | 3 |
3 | 13 | 1281.40 | 18 | 15.14 | 2020 | 550 | 1.67 / 167.23 | 2 | 3 |
4 | 13 | 1012.88 | 18 | 15.12 | 1668 | 454 | 2.13 / 167.68 | 2 | 3 |
5 | 13 | 224.68 | 18 | 15.26 | 590 | 162 | 2.29 / 167.85 | 2 | 3 |
6 | 8 | 0.40 | 165 | 15.26 | 263 | 662 | 2.95 / 168.51 | 2 | 10 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 29 | 15.25 | 424 | 188 | 0.19 / 163.01 | 2 | 2 |
2 | 7 | 1154.84 | 29 | 15.25 | 1851 | 819 | 1.01 / 163.82 | 2 | 3 |
3 | 13 | 1112.96 | 18 | 15.21 | 1801 | 493 | 1.50 / 164.32 | 2 | 3 |
4 | 13 | 868.88 | 18 | 15.20 | 1473 | 403 | 1.90 / 164.72 | 2 | 3 |
5 | 13 | 273.92 | 18 | 15.27 | 658 | 181 | 2.08 / 164.90 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.28 | 260 | 656 | 2.74 / 165.56 | 2 | 4 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 29 | 15.26 | 409 | 181 | 0.18 / 160.31 | 2 | 2 |
2 | 7 | 1094.80 | 29 | 15.29 | 1776 | 787 | 0.97 / 161.10 | 2 | 3 |
3 | 13 | 1071.32 | 18 | 15.23 | 1746 | 479 | 1.45 / 161.58 | 2 | 3 |
4 | 13 | 951.28 | 18 | 15.19 | 1586 | 434 | 1.88 / 162.01 | 2 | 3 |
5 | 13 | 189.24 | 18 | 15.30 | 536 | 148 | 2.03 / 162.16 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.30 | 260 | 656 | 2.68 / 162.82 | 2 | 8 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 15.25 | 405 | 179 | 0.18 / 157.73 | 2 | 2 |
2 | 7 | 1014.92 | 30 | 15.32 | 1652 | 759 | 0.94 / 158.49 | 2 | 3 |
3 | 13 | 1014.40 | 18 | 15.27 | 1663 | 457 | 1.40 / 158.95 | 2 | 3 |
4 | 13 | 890.24 | 18 | 15.22 | 1483 | 406 | 1.80 / 159.36 | 2 | 3 |
5 | 13 | 166.52 | 18 | 15.30 | 496 | 137 | 1.94 / 159.49 | 2 | 2 |
6 | 8 | -0.16 | 165 | 15.30 | 254 | 641 | 2.58 / 160.13 | 2 | 8 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 29 | 15.28 | 410 | 182 | 0.18 / 155.15 | 2 | 2 |
2 | 7 | 1030.80 | 29 | 15.32 | 1673 | 743 | 0.92 / 155.89 | 2 | 3 |
3 | 13 | 1030.24 | 18 | 15.26 | 1679 | 461 | 1.39 / 156.35 | 2 | 3 |
4 | 13 | 904.60 | 18 | 15.24 | 1509 | 414 | 1.80 / 156.76 | 2 | 3 |
5 | 13 | 173.08 | 18 | 15.31 | 509 | 140 | 1.94 / 156.90 | 2 | 2 |
6 | 8 | 0.36 | 165 | 15.30 | 257 | 649 | 2.59 / 157.55 | 2 | 8 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 29 | 15.24 | 412 | 182 | 0.18 / 152.59 | 2 | 2 |
2 | 7 | 1003.16 | 29 | 15.32 | 1638 | 728 | 0.91 / 153.32 | 2 | 3 |
3 | 13 | 1002.68 | 18 | 15.28 | 1640 | 451 | 1.36 / 153.77 | 2 | 3 |
4 | 13 | 880.20 | 18 | 15.25 | 1480 | 406 | 1.77 / 154.18 | 2 | 3 |
5 | 13 | 175.68 | 18 | 15.33 | 512 | 141 | 1.91 / 154.32 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.31 | 255 | 644 | 2.55 / 154.96 | 2 | 6 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 15.26 | 417 | 178 | 0.18 / 149.95 | 2 | 3 |
2 | 3 | 1018.52 | 1 | 15.33 | 1751 | 27 | 0.21 / 149.98 | 2 | 2 |
3 | 7 | 1041.76 | 29 | 15.32 | 1691 | 751 | 0.96 / 150.73 | 2 | 3 |
4 | 13 | 1040.64 | 18 | 15.27 | 1688 | 464 | 1.42 / 151.19 | 2 | 3 |
5 | 13 | 923.64 | 18 | 15.23 | 1538 | 422 | 1.84 / 151.61 | 2 | 3 |
6 | 13 | 192.28 | 18 | 15.30 | 538 | 148 | 1.99 / 151.76 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.31 | 257 | 649 | 2.64 / 152.41 | 2 | 3 |
Average= | 3.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 29 | 15.27 | 418 | 185 | 0.19 / 147.30 | 2 | 2 |
2 | 7 | 1061.80 | 29 | 15.32 | 1719 | 764 | 0.95 / 148.07 | 2 | 3 |
3 | 13 | 1061.28 | 18 | 15.25 | 1723 | 473 | 1.42 / 148.54 | 2 | 3 |
4 | 13 | 935.60 | 18 | 15.23 | 1556 | 427 | 1.85 / 148.97 | 2 | 3 |
5 | 13 | 187.40 | 18 | 15.31 | 527 | 145 | 1.99 / 149.11 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.32 | 261 | 660 | 2.65 / 149.77 | 2 | 4 |
Average= | 3.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 29 | 15.27 | 424 | 188 | 0.19 / 144.71 | 2 | 2 |
2 | 7 | 1019.92 | 29 | 15.32 | 1664 | 739 | 0.93 / 145.45 | 2 | 3 |
3 | 13 | 1019.56 | 18 | 15.27 | 1664 | 457 | 1.38 / 145.90 | 2 | 3 |
4 | 13 | 904.84 | 18 | 15.23 | 1510 | 414 | 1.80 / 146.32 | 2 | 3 |
5 | 13 | 170.52 | 18 | 15.31 | 507 | 140 | 1.94 / 146.46 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.32 | 262 | 662 | 2.60 / 147.12 | 2 | 7 |
Average= | 3.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 15.27 | 421 | 186 | 0.19 / 142.05 | 2 | 2 |
2 | 7 | 1045.96 | 29 | 15.31 | 1694 | 752 | 0.94 / 142.80 | 2 | 3 |
3 | 13 | 1046.04 | 18 | 15.26 | 1696 | 466 | 1.40 / 143.26 | 2 | 3 |
4 | 13 | 926.24 | 18 | 15.24 | 1537 | 422 | 1.83 / 143.69 | 2 | 3 |
5 | 13 | 199.72 | 18 | 15.31 | 552 | 152 | 1.98 / 143.84 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.32 | 269 | 680 | 2.66 / 144.52 | 2 | 8 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 29 | 15.27 | 412 | 182 | 0.18 / 139.20 | 2 | 2 |
2 | 7 | 1117.92 | 29 | 15.31 | 1797 | 798 | 0.98 / 139.99 | 2 | 3 |
3 | 13 | 1093.80 | 18 | 15.26 | 1774 | 487 | 1.47 / 140.48 | 2 | 4 |
4 | 13 | 971.32 | 18 | 15.22 | 1617 | 443 | 1.91 / 140.92 | 2 | 3 |
5 | 13 | 202.12 | 18 | 15.32 | 558 | 154 | 2.06 / 141.08 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.33 | 262 | 663 | 2.73 / 141.74 | 2 | 19 |
7 | 14 | 0.00 | 30 | 15.30 | 263 | 121 | 2.85 / 141.86 | 2 | 6 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 29 | 15.27 | 423 | 187 | 0.19 / 136.37 | 2 | 2 |
2 | 7 | 1166.00 | 29 | 15.27 | 1863 | 825 | 1.01 / 137.20 | 2 | 3 |
3 | 13 | 1117.68 | 18 | 15.22 | 1802 | 494 | 1.51 / 137.69 | 2 | 3 |
4 | 13 | 868.56 | 18 | 15.23 | 1469 | 403 | 1.91 / 138.09 | 2 | 3 |
5 | 13 | 148.24 | 18 | 15.32 | 474 | 131 | 2.04 / 138.23 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.30 | 264 | 666 | 2.71 / 138.89 | 2 | 3 |
7 | 14 | 0.20 | 30 | 15.30 | 264 | 121 | 2.83 / 139.01 | 2 | 7 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 15.27 | 420 | 186 | 0.19 / 133.64 | 2 | 2 |
2 | 7 | 1069.76 | 29 | 15.32 | 1736 | 771 | 0.96 / 134.41 | 2 | 3 |
3 | 13 | 1057.32 | 18 | 15.27 | 1723 | 474 | 1.43 / 134.89 | 2 | 3 |
4 | 13 | 932.48 | 18 | 15.23 | 1552 | 425 | 1.86 / 135.31 | 2 | 3 |
5 | 13 | 320.64 | 18 | 15.31 | 719 | 198 | 2.05 / 135.51 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.32 | 267 | 675 | 2.73 / 136.19 | 2 | 5 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 15.27 | 419 | 186 | 0.19 / 130.85 | 2 | 2 |
2 | 7 | 1067.00 | 29 | 15.31 | 1736 | 771 | 0.96 / 131.62 | 2 | 4 |
3 | 13 | 1066.52 | 18 | 15.25 | 1732 | 475 | 1.43 / 132.09 | 2 | 3 |
4 | 13 | 955.68 | 18 | 15.22 | 1583 | 434 | 1.87 / 132.53 | 2 | 3 |
5 | 13 | 205.32 | 18 | 15.32 | 561 | 155 | 2.02 / 132.68 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.32 | 259 | 655 | 2.67 / 133.34 | 2 | 6 |
7 | 14 | -0.04 | 30 | 15.29 | 264 | 121 | 2.80 / 133.46 | 2 | 6 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 29 | 15.27 | 416 | 184 | 0.18 / 128.16 | 2 | 2 |
2 | 7 | 1122.24 | 29 | 15.29 | 1800 | 798 | 0.98 / 128.96 | 2 | 3 |
3 | 13 | 1093.24 | 18 | 15.24 | 1763 | 484 | 1.47 / 129.44 | 2 | 3 |
4 | 13 | 875.12 | 18 | 15.22 | 1481 | 406 | 1.87 / 129.85 | 2 | 3 |
5 | 13 | 173.20 | 18 | 15.31 | 513 | 141 | 2.01 / 129.99 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.30 | 265 | 669 | 2.68 / 130.66 | 2 | 10 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 15.27 | 411 | 182 | 0.18 / 125.41 | 2 | 2 |
2 | 7 | 1113.84 | 30 | 15.31 | 1797 | 825 | 1.01 / 126.24 | 2 | 2 |
3 | 13 | 1088.80 | 18 | 15.26 | 1760 | 483 | 1.49 / 126.72 | 2 | 3 |
4 | 13 | 962.36 | 18 | 15.23 | 1592 | 436 | 1.93 / 127.16 | 2 | 3 |
5 | 13 | 197.04 | 18 | 15.33 | 551 | 152 | 2.08 / 127.31 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.32 | 264 | 667 | 2.75 / 127.98 | 2 | 4 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 29 | 15.25 | 417 | 184 | 0.18 / 122.74 | 2 | 2 |
2 | 7 | 1134.60 | 29 | 15.30 | 1822 | 808 | 0.99 / 123.55 | 2 | 2 |
3 | 13 | 1105.68 | 18 | 15.26 | 1798 | 494 | 1.49 / 124.04 | 2 | 3 |
4 | 13 | 859.64 | 18 | 15.23 | 1449 | 397 | 1.88 / 124.44 | 2 | 3 |
5 | 13 | 156.72 | 18 | 15.31 | 489 | 135 | 2.02 / 124.58 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.32 | 259 | 655 | 2.67 / 125.23 | 2 | 3 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 29 | 15.25 | 418 | 185 | 0.18 / 119.91 | 2 | 2 |
2 | 7 | 1229.48 | 29 | 15.28 | 1946 | 862 | 1.05 / 120.77 | 2 | 3 |
3 | 13 | 1228.88 | 18 | 15.20 | 1947 | 533 | 1.58 / 121.30 | 2 | 3 |
4 | 13 | 955.92 | 18 | 15.21 | 1581 | 433 | 2.01 / 121.74 | 2 | 3 |
5 | 13 | 216.44 | 18 | 15.31 | 570 | 157 | 2.17 / 121.89 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.30 | 263 | 664 | 2.83 / 122.56 | 2 | 3 |
Average= | 3.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 15.24 | 407 | 180 | 0.18 / 116.93 | 2 | 2 |
2 | 10 | 1000.24 | 2 | 15.27 | 1691 | 52 | 0.23 / 116.98 | 2 | 2 |
3 | 3 | 955.28 | -1 | 15.57 | 0 | 0 | 0.05 / 116.98 | 2 | 2 |
4 | 3 | 973.48 | -1 | 15.60 | 0 | 0 | 0.05 / 116.98 | 2 | 2 |
5 | 7 | 1354.92 | 29 | 15.23 | 2119 | 936 | 1.17 / 117.92 | 2 | 3 |
6 | 13 | 1275.92 | 18 | 15.18 | 2015 | 551 | 1.72 / 118.47 | 2 | 3 |
7 | 13 | 878.48 | 18 | 15.21 | 1492 | 408 | 2.13 / 118.88 | 2 | 3 |
8 | 13 | 313.68 | 18 | 15.29 | 708 | 195 | 2.32 / 119.07 | 2 | 3 |
9 | 8 | -0.12 | 165 | 15.29 | 258 | 651 | 2.97 / 119.72 | 2 | 5 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 29 | 15.21 | 418 | 184 | 0.18 / 113.76 | 2 | 2 |
2 | 7 | 1555.72 | 29 | 15.16 | 2371 | 1042 | 1.23 / 114.80 | 2 | 2 |
3 | 13 | 1448.96 | 18 | 15.11 | 2237 | 608 | 1.84 / 115.41 | 2 | 3 |
4 | 13 | 1006.80 | 18 | 15.15 | 1659 | 452 | 2.29 / 115.86 | 2 | 4 |
5 | 13 | 407.48 | 18 | 15.26 | 843 | 232 | 2.52 / 116.09 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.29 | 262 | 661 | 3.18 / 116.75 | 2 | 3 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 28 | 15.22 | 418 | 178 | 0.18 / 110.25 | 2 | 2 |
2 | 7 | 2009.12 | 29 | 15.04 | 2962 | 1292 | 1.47 / 111.54 | 2 | 3 |
3 | 13 | 1604.64 | 18 | 15.03 | 2449 | 663 | 2.13 / 112.20 | 2 | 3 |
4 | 13 | 926.24 | 18 | 15.10 | 1553 | 422 | 2.55 / 112.63 | 2 | 4 |
5 | 13 | 355.08 | 18 | 15.23 | 768 | 211 | 2.77 / 112.84 | 2 | 2 |
6 | 13 | 40.00 | 18 | 15.29 | 325 | 89 | 2.85 / 112.93 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.25 | 257 | 647 | 3.50 / 113.57 | 2 | 7 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 15.23 | 396 | 169 | 0.17 / 106.50 | 2 | 2 |
2 | 7 | 1970.56 | 29 | 15.03 | 2909 | 1268 | 1.44 / 107.77 | 2 | 5 |
3 | 13 | 1582.00 | 18 | 15.03 | 2424 | 656 | 2.09 / 108.43 | 2 | 3 |
4 | 13 | 1025.92 | 18 | 15.09 | 1699 | 461 | 2.55 / 108.89 | 2 | 3 |
5 | 13 | 591.40 | 18 | 15.18 | 1103 | 301 | 2.86 / 109.19 | 2 | 3 |
6 | 13 | 47.36 | 18 | 15.29 | 338 | 93 | 2.95 / 109.28 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.25 | 265 | 667 | 3.62 / 109.95 | 2 | 6 |
8 | 14 | 0.12 | 30 | 15.23 | 262 | 120 | 3.74 / 110.07 | 2 | 7 |
Average= | 3.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 28 | 15.23 | 392 | 167 | 0.17 / 103.14 | 2 | 2 |
2 | 7 | 1665.36 | 29 | 15.12 | 2527 | 1108 | 1.28 / 104.25 | 2 | 3 |
3 | 13 | 1541.24 | 18 | 15.07 | 2378 | 645 | 1.92 / 104.90 | 2 | 4 |
4 | 13 | 1101.72 | 18 | 15.10 | 1792 | 487 | 2.41 / 105.38 | 2 | 4 |
5 | 13 | 357.44 | 18 | 15.25 | 770 | 211 | 2.62 / 105.59 | 2 | 3 |
6 | 13 | 41.52 | 18 | 15.31 | 326 | 90 | 2.71 / 105.68 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.29 | 258 | 651 | 3.36 / 106.34 | 2 | 7 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 29 | 15.26 | 418 | 185 | 0.18 / 99.95 | 2 | 2 |
2 | 7 | 1573.92 | 29 | 15.16 | 2417 | 1063 | 1.25 / 101.01 | 2 | 4 |
3 | 13 | 1459.28 | 18 | 15.12 | 2273 | 619 | 1.87 / 101.63 | 2 | 3 |
4 | 13 | 911.88 | 18 | 15.19 | 1538 | 421 | 2.29 / 102.05 | 2 | 3 |
5 | 13 | 310.56 | 18 | 15.28 | 707 | 194 | 2.48 / 102.25 | 2 | 2 |
6 | 13 | 18.00 | 18 | 15.31 | 290 | 80 | 2.56 / 102.33 | 2 | 2 |
7 | 8 | 0.28 | 165 | 15.29 | 257 | 648 | 3.21 / 102.98 | 2 | 6 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 29 | 15.26 | 406 | 180 | 0.18 / 96.81 | 2 | 2 |
2 | 7 | 1425.60 | 29 | 15.21 | 2218 | 978 | 1.16 / 97.79 | 2 | 3 |
3 | 13 | 1332.32 | 18 | 15.19 | 2081 | 569 | 1.73 / 98.36 | 2 | 4 |
4 | 13 | 919.72 | 18 | 15.20 | 1544 | 422 | 2.15 / 98.78 | 2 | 3 |
5 | 13 | 450.64 | 18 | 15.25 | 905 | 248 | 2.40 / 99.03 | 2 | 3 |
6 | 13 | 23.04 | 18 | 15.33 | 301 | 83 | 2.48 / 99.11 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 259 | 654 | 3.13 / 99.77 | 2 | 6 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 29 | 15.26 | 414 | 183 | 0.18 / 93.66 | 2 | 2 |
2 | 7 | 1445.28 | 29 | 15.21 | 2247 | 991 | 1.17 / 94.65 | 2 | 2 |
3 | 13 | 1350.80 | 18 | 15.17 | 2120 | 579 | 1.75 / 95.23 | 2 | 3 |
4 | 13 | 955.52 | 18 | 15.20 | 1588 | 434 | 2.19 / 95.67 | 2 | 3 |
5 | 13 | 354.04 | 18 | 15.30 | 770 | 212 | 2.40 / 95.88 | 2 | 2 |
6 | 13 | 43.12 | 18 | 15.33 | 329 | 91 | 2.49 / 95.97 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.30 | 262 | 661 | 3.15 / 96.63 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 28 | 15.26 | 409 | 175 | 0.17 / 90.63 | 2 | 2 |
2 | 7 | 1384.88 | 29 | 15.24 | 2156 | 953 | 1.13 / 91.58 | 2 | 3 |
3 | 13 | 1295.28 | 18 | 15.17 | 2042 | 558 | 1.69 / 92.14 | 2 | 3 |
4 | 13 | 906.96 | 18 | 15.21 | 1529 | 419 | 2.10 / 92.56 | 2 | 3 |
5 | 13 | 295.80 | 18 | 15.29 | 682 | 188 | 2.29 / 92.75 | 2 | 3 |
6 | 13 | 28.24 | 18 | 15.33 | 305 | 84 | 2.38 / 92.83 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.31 | 257 | 649 | 3.02 / 93.48 | 2 | 6 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 28 | 15.26 | 383 | 164 | 0.16 / 87.48 | 2 | 2 |
2 | 7 | 1486.36 | 29 | 15.22 | 2282 | 1007 | 1.17 / 88.49 | 2 | 2 |
3 | 13 | 1382.56 | 18 | 15.17 | 2157 | 589 | 1.76 / 89.08 | 2 | 3 |
4 | 13 | 952.68 | 18 | 15.20 | 1590 | 435 | 2.19 / 89.51 | 2 | 3 |
5 | 13 | 357.76 | 18 | 15.30 | 767 | 211 | 2.41 / 89.72 | 2 | 3 |
6 | 13 | 19.08 | 18 | 15.34 | 289 | 80 | 2.49 / 89.80 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.31 | 258 | 652 | 3.14 / 90.46 | 2 | 8 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 28 | 15.25 | 389 | 166 | 0.17 / 84.30 | 2 | 2 |
2 | 7 | 1468.56 | 29 | 15.22 | 2270 | 1002 | 1.17 / 85.30 | 2 | 3 |
3 | 13 | 1376.00 | 18 | 15.17 | 2164 | 591 | 1.76 / 85.89 | 2 | 4 |
4 | 13 | 946.60 | 18 | 15.21 | 1584 | 434 | 2.19 / 86.32 | 2 | 3 |
5 | 13 | 223.24 | 18 | 15.32 | 580 | 160 | 2.35 / 86.48 | 2 | 2 |
6 | 13 | 23.24 | 18 | 15.34 | 292 | 81 | 2.43 / 86.56 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.31 | 253 | 639 | 3.07 / 87.20 | 2 | 6 |
8 | 14 | -0.04 | 30 | 15.30 | 253 | 116 | 3.19 / 87.32 | 2 | 12 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 28 | 15.27 | 411 | 176 | 0.18 / 81.32 | 2 | 2 |
2 | 7 | 1346.28 | 29 | 15.25 | 2104 | 930 | 1.11 / 82.25 | 2 | 3 |
3 | 13 | 1264.20 | 18 | 15.20 | 2004 | 548 | 1.65 / 82.80 | 2 | 4 |
4 | 13 | 990.52 | 18 | 15.22 | 1640 | 449 | 2.10 / 83.25 | 2 | 3 |
5 | 13 | 245.64 | 18 | 15.32 | 609 | 168 | 2.27 / 83.41 | 2 | 2 |
6 | 13 | 23.88 | 18 | 15.35 | 292 | 81 | 2.35 / 83.49 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.32 | 251 | 634 | 2.99 / 84.13 | 2 | 5 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 28 | 15.27 | 399 | 171 | 0.17 / 78.15 | 2 | 2 |
2 | 7 | 1378.44 | 29 | 15.25 | 2158 | 954 | 1.12 / 79.10 | 2 | 3 |
3 | 13 | 1290.04 | 18 | 15.19 | 2044 | 559 | 1.68 / 79.66 | 2 | 3 |
4 | 13 | 1014.56 | 18 | 15.20 | 1674 | 458 | 2.14 / 80.12 | 2 | 4 |
5 | 13 | 262.40 | 18 | 15.31 | 634 | 175 | 2.32 / 80.30 | 2 | 2 |
6 | 13 | 27.96 | 18 | 15.34 | 305 | 84 | 2.40 / 80.38 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.31 | 255 | 644 | 3.04 / 81.02 | 2 | 10 |
8 | 14 | 0.00 | 30 | 15.29 | 257 | 118 | 3.16 / 81.14 | 3 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 28 | 15.26 | 416 | 178 | 0.18 / 75.13 | 2 | 2 |
2 | 7 | 1410.60 | 29 | 15.26 | 2195 | 971 | 1.15 / 76.11 | 2 | 3 |
3 | 13 | 1322.68 | 18 | 15.21 | 2070 | 567 | 1.72 / 76.67 | 2 | 3 |
4 | 13 | 928.96 | 18 | 15.22 | 1555 | 426 | 2.14 / 77.10 | 2 | 3 |
5 | 13 | 221.40 | 18 | 15.33 | 580 | 160 | 2.30 / 77.26 | 2 | 2 |
6 | 13 | 24.00 | 18 | 15.35 | 296 | 82 | 2.38 / 77.34 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.32 | 253 | 640 | 3.02 / 77.98 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 28 | 15.26 | 404 | 173 | 0.17 / 71.95 | 2 | 2 |
2 | 3 | 1016.08 | 1 | 15.36 | 1752 | 27 | 0.20 / 71.98 | 2 | 2 |
3 | 7 | 1504.96 | 29 | 15.21 | 2324 | 1025 | 1.22 / 73.01 | 2 | 3 |
4 | 13 | 1403.56 | 18 | 15.17 | 2194 | 599 | 1.82 / 73.60 | 2 | 3 |
5 | 13 | 986.88 | 18 | 15.22 | 1644 | 450 | 2.27 / 74.05 | 2 | 3 |
6 | 13 | 265.60 | 18 | 15.32 | 636 | 175 | 2.45 / 74.23 | 2 | 2 |
7 | 13 | 28.96 | 18 | 15.35 | 304 | 84 | 2.53 / 74.31 | 2 | 2 |
8 | 8 | -0.08 | 165 | 15.32 | 254 | 642 | 3.18 / 74.96 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 28 | 15.29 | 403 | 173 | 0.17 / 68.79 | 2 | 2 |
2 | 7 | 1410.60 | 29 | 15.24 | 2203 | 974 | 1.15 / 69.76 | 2 | 4 |
3 | 13 | 1317.84 | 18 | 15.20 | 2074 | 567 | 1.71 / 70.33 | 2 | 3 |
4 | 13 | 911.88 | 18 | 15.22 | 1545 | 423 | 2.14 / 70.75 | 2 | 3 |
5 | 13 | 312.16 | 18 | 15.32 | 704 | 194 | 2.33 / 70.95 | 2 | 2 |
6 | 13 | 34.96 | 18 | 15.34 | 312 | 86 | 2.42 / 71.03 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.32 | 250 | 632 | 3.05 / 71.67 | 2 | 9 |
8 | 14 | 0.20 | 30 | 15.30 | 251 | 115 | 3.16 / 71.78 | 3 | 9 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 28 | 15.27 | 409 | 175 | 0.17 / 65.62 | 2 | 2 |
2 | 7 | 1526.64 | 29 | 15.20 | 2352 | 1037 | 1.21 / 66.65 | 2 | 3 |
3 | 13 | 1417.16 | 18 | 15.15 | 2207 | 602 | 1.81 / 67.25 | 2 | 4 |
4 | 13 | 998.48 | 18 | 15.21 | 1654 | 453 | 2.27 / 67.71 | 2 | 3 |
5 | 13 | 262.00 | 18 | 15.33 | 632 | 174 | 2.44 / 67.88 | 2 | 2 |
6 | 13 | 52.60 | 18 | 15.34 | 336 | 93 | 2.53 / 67.97 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.33 | 254 | 642 | 3.18 / 68.62 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 28 | 15.28 | 408 | 175 | 0.17 / 62.49 | 2 | 2 |
2 | 7 | 1466.16 | 29 | 15.21 | 2281 | 1006 | 1.18 / 63.50 | 2 | 3 |
3 | 13 | 1365.56 | 18 | 15.16 | 2139 | 584 | 1.76 / 64.08 | 2 | 3 |
4 | 13 | 946.40 | 18 | 15.19 | 1585 | 433 | 2.20 / 64.52 | 2 | 3 |
5 | 13 | 332.56 | 18 | 15.30 | 736 | 203 | 2.40 / 64.72 | 2 | 2 |
6 | 13 | 14.64 | 18 | 15.34 | 283 | 78 | 2.48 / 64.80 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.31 | 255 | 644 | 3.12 / 65.44 | 2 | 8 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 28 | 15.30 | 405 | 174 | 0.17 / 59.39 | 2 | 2 |
2 | 7 | 1491.84 | 29 | 15.21 | 2305 | 1017 | 1.19 / 60.40 | 2 | 3 |
3 | 13 | 1388.28 | 18 | 15.15 | 2166 | 591 | 1.78 / 60.99 | 2 | 3 |
4 | 13 | 966.36 | 18 | 15.20 | 1596 | 437 | 2.22 / 61.43 | 2 | 3 |
5 | 13 | 230.44 | 18 | 15.32 | 592 | 163 | 2.38 / 61.59 | 2 | 2 |
6 | 13 | 19.72 | 18 | 15.35 | 291 | 80 | 2.46 / 61.67 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.32 | 255 | 645 | 3.11 / 62.32 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 28 | 15.28 | 415 | 178 | 0.18 / 56.42 | 2 | 2 |
2 | 7 | 1456.64 | 29 | 15.24 | 2253 | 996 | 1.17 / 57.41 | 2 | 3 |
3 | 13 | 1352.36 | 18 | 15.19 | 2126 | 581 | 1.75 / 57.99 | 2 | 3 |
4 | 13 | 836.00 | 18 | 15.24 | 1441 | 395 | 2.15 / 58.39 | 2 | 3 |
5 | 13 | 266.00 | 18 | 15.33 | 643 | 177 | 2.33 / 58.57 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.33 | 255 | 645 | 2.97 / 59.21 | 2 | 7 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 28 | 15.27 | 417 | 178 | 0.18 / 53.32 | 2 | 2 |
2 | 7 | 1532.48 | 29 | 15.21 | 2354 | 1038 | 1.22 / 54.36 | 2 | 3 |
3 | 13 | 1426.04 | 18 | 15.17 | 2222 | 607 | 1.82 / 54.97 | 2 | 3 |
4 | 13 | 987.68 | 18 | 15.23 | 1648 | 452 | 2.28 / 55.42 | 2 | 3 |
5 | 13 | 255.36 | 18 | 15.33 | 628 | 173 | 2.45 / 55.59 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.33 | 256 | 648 | 3.10 / 56.24 | 2 | 6 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 28 | 15.30 | 405 | 174 | 0.17 / 50.01 | 2 | 2 |
2 | 7 | 1746.20 | 29 | 15.14 | 2634 | 1156 | 1.33 / 51.17 | 2 | 5 |
3 | 13 | 1494.00 | 18 | 15.11 | 2320 | 631 | 1.96 / 51.80 | 2 | 4 |
4 | 13 | 1061.20 | 18 | 15.15 | 1750 | 477 | 2.44 / 52.28 | 2 | 3 |
5 | 13 | 330.76 | 18 | 15.31 | 739 | 204 | 2.64 / 52.48 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.32 | 263 | 665 | 3.31 / 53.14 | 2 | 7 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 28 | 15.30 | 407 | 174 | 0.17 / 46.75 | 2 | 2 |
2 | 7 | 1728.76 | 29 | 15.14 | 2621 | 1151 | 1.33 / 47.90 | 2 | 5 |
3 | 13 | 1482.48 | 18 | 15.11 | 2289 | 623 | 1.95 / 48.52 | 2 | 3 |
4 | 13 | 1046.00 | 18 | 15.18 | 1725 | 471 | 2.42 / 48.99 | 2 | 4 |
5 | 13 | 303.96 | 18 | 15.30 | 695 | 191 | 2.61 / 49.18 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.33 | 259 | 655 | 3.27 / 49.84 | 2 | 4 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 28 | 15.30 | 405 | 174 | 0.17 / 43.66 | 2 | 2 |
2 | 7 | 1516.80 | 30 | 15.21 | 2327 | 1062 | 1.24 / 44.72 | 2 | 3 |
3 | 13 | 1409.16 | 18 | 15.17 | 2191 | 598 | 1.83 / 45.32 | 2 | 3 |
4 | 13 | 982.32 | 18 | 15.22 | 1627 | 446 | 2.28 / 45.76 | 2 | 4 |
5 | 13 | 243.00 | 18 | 15.33 | 602 | 166 | 2.45 / 45.93 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.34 | 254 | 643 | 3.09 / 46.57 | 2 | 4 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 28 | 15.29 | 419 | 179 | 0.18 / 40.67 | 2 | 2 |
2 | 7 | 1418.72 | 29 | 15.25 | 2211 | 978 | 1.16 / 41.64 | 2 | 3 |
3 | 13 | 1322.68 | 18 | 15.21 | 2087 | 571 | 1.73 / 42.22 | 2 | 3 |
4 | 13 | 907.20 | 18 | 15.25 | 1526 | 419 | 2.15 / 42.63 | 2 | 3 |
5 | 13 | 304.76 | 18 | 15.35 | 696 | 192 | 2.34 / 42.83 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.36 | 259 | 656 | 3.00 / 43.48 | 2 | 6 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 28 | 15.30 | 404 | 173 | 0.17 / 37.52 | 2 | 2 |
2 | 7 | 1625.08 | 29 | 15.21 | 2484 | 1096 | 1.27 / 38.61 | 2 | 3 |
3 | 13 | 1505.36 | 18 | 15.15 | 2326 | 634 | 1.90 / 39.25 | 2 | 4 |
4 | 13 | 941.24 | 18 | 15.23 | 1575 | 432 | 2.33 / 39.68 | 2 | 3 |
5 | 13 | 238.96 | 18 | 15.36 | 600 | 166 | 2.50 / 39.85 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.35 | 253 | 641 | 3.14 / 40.49 | 2 | 6 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 28 | 15.31 | 413 | 177 | 0.18 / 34.21 | 2 | 2 |
2 | 7 | 1756.64 | 29 | 15.15 | 2650 | 1164 | 1.34 / 35.38 | 2 | 3 |
3 | 13 | 1509.72 | 18 | 15.13 | 2346 | 639 | 1.98 / 36.01 | 2 | 3 |
4 | 13 | 1066.00 | 18 | 15.16 | 1749 | 477 | 2.46 / 36.49 | 2 | 3 |
5 | 13 | 325.24 | 18 | 15.31 | 726 | 200 | 2.66 / 36.69 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.34 | 258 | 653 | 3.31 / 37.35 | 2 | 5 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 27 | 15.30 | 405 | 167 | 0.17 / 31.03 | 2 | 2 |
2 | 3 | 1017.28 | 1 | 15.38 | 1734 | 27 | 0.19 / 31.06 | 2 | 3 |
3 | 7 | 1546.76 | 28 | 15.24 | 2389 | 1019 | 1.21 / 32.08 | 2 | 3 |
4 | 13 | 1438.68 | 18 | 15.20 | 2237 | 612 | 1.83 / 32.69 | 2 | 3 |
5 | 13 | 1014.28 | 18 | 15.23 | 1678 | 460 | 2.29 / 33.15 | 2 | 3 |
6 | 13 | 395.36 | 18 | 15.33 | 822 | 227 | 2.51 / 33.38 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.37 | 259 | 657 | 3.17 / 34.03 | 2 | 7 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 27 | 15.32 | 411 | 170 | 0.17 / 27.62 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 15.07 | 2954 | 1380 | 1.55 / 29.00 | 2 | 4 |
3 | 13 | 1438.04 | 18 | 15.10 | 2244 | 610 | 2.16 / 29.61 | 2 | 3 |
4 | 13 | 881.80 | 18 | 15.19 | 1493 | 408 | 2.57 / 30.02 | 2 | 3 |
5 | 13 | 295.92 | 18 | 15.31 | 682 | 188 | 2.76 / 30.21 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.33 | 260 | 658 | 3.41 / 30.87 | 2 | 4 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 27 | 15.30 | 409 | 169 | 0.17 / 24.21 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 15.07 | 2953 | 1380 | 1.55 / 25.59 | 2 | 7 |
3 | 13 | 1427.00 | 18 | 15.13 | 2227 | 607 | 2.16 / 26.20 | 2 | 3 |
4 | 13 | 976.84 | 18 | 15.19 | 1629 | 445 | 2.60 / 26.65 | 2 | 3 |
5 | 13 | 227.40 | 18 | 15.35 | 582 | 161 | 2.76 / 26.81 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.35 | 255 | 646 | 3.41 / 27.45 | 2 | 7 |
Average= | 3.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 27 | 15.30 | 415 | 171 | 0.17 / 20.79 | 2 | 2 |
2 | 7 | 2003.92 | 31 | 15.09 | 2948 | 1379 | 1.55 / 22.17 | 2 | 3 |
3 | 13 | 1456.04 | 18 | 15.11 | 2263 | 615 | 2.17 / 22.78 | 2 | 3 |
4 | 13 | 905.40 | 18 | 15.20 | 1526 | 418 | 2.58 / 23.20 | 2 | 4 |
5 | 13 | 315.96 | 18 | 15.31 | 707 | 195 | 2.78 / 23.39 | 2 | 2 |
6 | 8 | 0.24 | 165 | 15.35 | 257 | 651 | 3.43 / 24.04 | 2 | 5 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 27 | 15.31 | 406 | 168 | 0.17 / 17.28 | 2 | 2 |
2 | 3 | 1016.96 | 1 | 15.38 | 1743 | 27 | 0.19 / 17.31 | 2 | 3 |
3 | 7 | 2006.36 | 38 | 15.04 | 2946 | 1684 | 1.88 / 18.99 | 2 | 6 |
4 | 13 | 1247.92 | 18 | 15.15 | 1981 | 540 | 2.42 / 19.53 | 2 | 3 |
5 | 13 | 674.12 | 18 | 15.26 | 1207 | 332 | 2.75 / 19.86 | 2 | 3 |
6 | 13 | 109.04 | 18 | 15.35 | 411 | 114 | 2.86 / 19.97 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.35 | 253 | 641 | 3.50 / 20.62 | 2 | 4 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 29 | 15.32 | 402 | 179 | 0.18 / 13.77 | 2 | 2 |
2 | 3 | 883.32 | -3 | 15.64 | 0 | 0 | 0.00 / 13.77 | 2 | 2 |
3 | 7 | 2003.68 | 39 | 15.02 | 2941 | 1723 | 1.90 / 15.49 | 2 | 3 |
4 | 13 | 1253.40 | 18 | 15.14 | 1986 | 541 | 2.44 / 16.03 | 2 | 3 |
5 | 13 | 672.44 | 18 | 15.26 | 1203 | 330 | 2.77 / 16.36 | 2 | 3 |
6 | 13 | 108.20 | 18 | 15.36 | 408 | 113 | 2.89 / 16.47 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.35 | 252 | 638 | 3.52 / 17.11 | 2 | 6 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 26 | 15.34 | 385 | 154 | 0.15 / 10.64 | 2 | 2 |
2 | 7 | 1516.60 | 38 | 15.18 | 2308 | 1331 | 1.48 / 11.98 | 2 | 4 |
3 | 13 | 1121.48 | 18 | 15.20 | 1801 | 493 | 1.98 / 12.47 | 2 | 3 |
4 | 13 | 545.88 | 18 | 15.32 | 1029 | 284 | 2.26 / 12.75 | 2 | 3 |
5 | 13 | 57.96 | 18 | 15.40 | 332 | 92 | 2.35 / 12.84 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.37 | 248 | 629 | 2.98 / 13.47 | 2 | 4 |
7 | 14 | 0.20 | 30 | 15.34 | 247 | 114 | 3.10 / 13.59 | 2 | 9 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 25 | 15.32 | 399 | 153 | 0.15 / 7.63 | 2 | 2 |
2 | 3 | 1056.96 | 2 | 15.35 | 1765 | 54 | 0.21 / 7.69 | 2 | 3 |
3 | 7 | 1517.64 | 39 | 15.17 | 2303 | 1363 | 1.57 / 9.05 | 2 | 3 |
4 | 13 | 1122.36 | 18 | 15.23 | 1805 | 495 | 2.06 / 9.55 | 2 | 5 |
5 | 13 | 426.40 | 18 | 15.34 | 857 | 237 | 2.30 / 9.78 | 2 | 3 |
6 | 13 | 32.44 | 18 | 15.39 | 296 | 82 | 2.38 / 9.86 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.37 | 247 | 626 | 3.01 / 10.49 | 2 | 5 |
Average= | 2.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 32 | 15.32 | 399 | 196 | 0.20 / 4.19 | 2 | 2 |
2 | 3 | 758.56 | -5 | 15.65 | 1 | 0 | 0.00 / 4.19 | 2 | 2 |
3 | 3 | 950.52 | -1 | 15.67 | 1 | 0 | 0.00 / 4.19 | 2 | 2 |
4 | 7 | 1511.40 | 74 | 15.09 | 2286 | 2553 | 2.75 / 6.75 | 2 | 4 |
5 | 13 | 96.56 | 18 | 15.37 | 389 | 108 | 2.86 / 6.85 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.36 | 248 | 629 | 3.48 / 7.48 | 2 | 5 |
Average= | 2.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 27 | 15.48 | 372 | 155 | 0.16 / 1.53 | 2 | 2 |
2 | 3 | 950.48 | -1 | 15.65 | 1 | 0 | 0.00 / 1.53 | 2 | 2 |
3 | 7 | 994.08 | 75 | 15.22 | 1598 | 1824 | 1.98 / 3.36 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.37 | 253 | 642 | 2.62 / 4.00 | 2 | 4 |
Average= | 2.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 96.48 | 26 | 15.61 | 366 | 149 | 0.15 / 0.15 | 2 | 2 |
2 | 7 | 110.00 | 74 | 15.58 | 369 | 425 | 0.57 / 0.57 | 2 | 2 |
3 | 8 | 0.24 | 240 | 15.54 | 215 | 802 | 1.38 / 1.38 | 2 | 11 |
Average= | 1.38 (KJ/cycle) |