SIO Argo Site:
Pump Diagnostics Page   



Serial= 8923 WMO= 5906422

Return

←PreviousNext→

Cycle 122 GMT 1/ 9/2024 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 1 15.15 420 6 0.01 / 424.30 2 2
2 10 522.28 9 15.06 969 131 0.14 / 424.43 2 2
3 3 534.08 1 15.15 993 15 0.15 / 424.45 2 3
4 3 533.84 1 15.17 1000 15 0.17 / 424.46 2 2
5 7 681.00 41 15.21 1148 716 0.88 / 425.18 2 3
6 13 584.56 20 15.18 1063 323 1.21 / 425.50 2 3
7 13 71.76 20 15.20 381 116 1.32 / 425.62 2 3
8 8 -0.08 165 15.17 283 708 2.03 / 426.33 2 7
Average= 3.47
(KJ/cycle)

Cycle 121 GMT 23/ 8/2024 8: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 15 15.18 407 93 0.09 / 422.58 2 2
2 3 493.96 -4 15.36 0 0 0.00 / 422.58 2 2
3 3 491.44 -4 15.37 0 0 0.00 / 422.58 2 2
4 7 529.72 41 15.23 968 604 0.70 / 423.19 2 3
5 13 529.08 20 15.20 964 293 0.99 / 423.48 2 3
6 13 128.40 20 15.21 440 134 1.12 / 423.61 2 2
7 8 0.00 165 15.17 273 683 1.81 / 424.30 2 6
Average= 3.48
(KJ/cycle)

Cycle 120 GMT 13/ 8/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 33 15.11 440 219 0.22 / 421.06 2 2
2 3 441.80 -5 15.38 1 0 0.00 / 421.06 2 2
3 3 456.92 -5 15.40 0 0 0.00 / 421.06 2 2
4 7 492.56 41 15.26 906 567 0.79 / 421.63 2 2
5 13 363.84 20 15.25 742 226 1.01 / 421.86 2 3
6 8 -0.08 165 15.24 251 631 1.64 / 422.49 2 4
Average= 3.49
(KJ/cycle)

Cycle 119 GMT 3/ 8/2024 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 41 15.14 459 285 0.28 / 418.82 2 2
2 10 735.88 3 15.10 1265 57 0.34 / 418.87 2 3
3 3 547.80 -3 15.35 0 0 0.06 / 418.87 2 3
4 3 552.00 -3 15.37 0 0 0.06 / 418.87 2 3
5 7 807.96 41 15.16 1332 828 1.17 / 419.70 2 5
6 13 51.64 20 15.23 363 111 1.28 / 419.81 2 3
7 8 0.32 165 15.20 283 710 1.99 / 420.52 2 3
8 14 0.32 75 15.17 283 322 2.31 / 420.84 2 11
Average= 3.51
(KJ/cycle)

Cycle 118 GMT 2/ 8/2024 14: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 41 15.13 444 275 0.28 / 417.08 2 2
2 7 691.84 41 15.18 1169 728 1.00 / 417.80 2 4
3 8 0.00 165 15.21 290 728 1.73 / 418.53 2 5
Average= 3.52
(KJ/cycle)

Cycle 117 GMT 23/ 7/2024 21:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 40 15.09 437 264 0.26 / 415.32 2 2
2 3 722.72 1 15.15 1237 19 0.28 / 415.34 2 2
3 7 705.68 41 15.20 1200 748 1.03 / 416.08 2 3
4 8 0.32 165 15.22 286 718 1.75 / 416.80 2 6
Average= 3.53
(KJ/cycle)

Cycle 116 GMT 14/ 7/2024 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 40 15.16 427 259 0.26 / 413.26 2 2
2 3 724.24 1 15.17 1235 19 0.28 / 413.28 2 2
3 7 711.60 41 15.18 1205 750 1.03 / 414.03 2 4
4 8 -0.44 165 15.20 283 710 1.74 / 414.74 2 10
5 14 -0.44 75 15.16 278 316 2.05 / 415.05 2 11
Average= 3.55
(KJ/cycle)

Cycle 115 GMT 4/ 7/2024 13:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 36 15.10 454 247 0.25 / 411.45 2 2
2 10 741.76 2 15.15 1271 39 0.29 / 411.49 2 2
3 3 733.52 1 15.22 1258 19 0.30 / 411.50 2 3
4 3 749.20 1 15.23 1277 19 0.32 / 411.52 2 3
5 7 717.28 42 15.23 1206 771 1.10 / 412.30 2 3
6 8 0.16 165 15.25 280 705 1.80 / 413.00 2 5
Average= 3.56
(KJ/cycle)

Cycle 114 GMT 24/ 6/2024 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 26 15.06 465 182 0.18 / 409.35 2 2
2 10 765.52 4 15.03 1287 77 0.26 / 409.42 2 2
3 3 777.28 2 15.15 1319 40 0.30 / 409.46 2 2
4 3 813.72 3 15.16 1356 62 0.36 / 409.53 2 3
5 7 835.80 41 15.10 1351 836 1.20 / 410.36 2 5
6 13 84.16 20 15.18 405 123 1.32 / 410.48 2 2
7 8 -0.04 165 15.15 286 715 2.04 / 411.20 2 7
Average= 3.58
(KJ/cycle)

Cycle 113 GMT 24/ 6/2024 9: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 26 15.02 437 171 0.17 / 406.78 2 2
2 3 951.00 -1 15.38 1 0 0.00 / 406.78 2 2
3 3 948.40 -1 15.40 0 0 0.00 / 406.78 2 2
4 7 834.12 41 15.19 1342 836 1.01 / 407.61 2 4
5 13 799.36 20 15.16 1301 394 1.40 / 408.01 2 3
6 13 682.44 20 15.14 1152 349 1.75 / 408.35 2 3
7 13 43.64 20 15.18 347 105 1.86 / 408.46 2 3
8 8 0.32 165 15.13 282 704 2.56 / 409.16 2 7
Average= 3.59
(KJ/cycle)

Cycle 112 GMT 14/ 6/2024 10:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 33 15.07 430 214 0.21 / 403.74 2 2
2 3 914.24 -2 15.39 0 0 0.00 / 403.74 2 2
3 3 907.20 -2 15.42 1 0 0.00 / 403.74 2 2
4 7 964.96 41 15.14 1508 936 1.15 / 404.67 2 2
5 13 895.04 20 15.12 1428 432 1.58 / 405.11 2 6
6 13 768.56 20 15.09 1292 390 1.97 / 405.50 2 3
7 13 35.68 20 15.14 334 101 2.07 / 405.60 2 2
8 8 -0.12 165 15.11 279 696 2.77 / 406.29 2 6
9 14 -0.12 75 15.07 277 313 3.08 / 406.61 3 9
Average= 3.60
(KJ/cycle)

Cycle 111 GMT 4/ 6/2024 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 33 15.00 446 221 0.22 / 401.04 2 2
2 7 889.64 41 15.17 1418 882 1.10 / 401.92 2 2
3 13 795.08 20 15.16 1313 398 1.50 / 402.32 2 3
4 13 686.20 20 15.14 1189 360 1.86 / 402.68 2 3
5 13 102.04 20 15.18 432 131 1.99 / 402.81 2 3
6 8 0.12 165 15.14 287 717 2.71 / 403.52 2 6
Average= 3.60
(KJ/cycle)

Cycle 110 GMT 25/ 5/2024 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 33 15.02 421 209 0.21 / 397.90 2 2
2 7 1285.32 41 15.03 1905 1174 1.38 / 399.07 2 3
3 13 1181.28 20 15.02 1805 542 1.92 / 399.62 2 4
4 13 759.76 20 15.03 1297 390 2.31 / 400.01 2 5
5 13 75.68 20 15.11 388 117 2.43 / 400.12 2 2
6 8 0.00 165 15.08 278 692 3.12 / 400.81 2 8
Average= 3.61
(KJ/cycle)

Cycle 109 GMT 15/ 5/2024 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 33 15.02 434 215 0.22 / 394.86 2 2
2 7 1225.52 41 15.05 1836 1133 1.35 / 395.99 2 3
3 13 1129.56 20 15.05 1726 520 1.87 / 396.51 2 5
4 13 693.28 20 15.06 1212 365 2.23 / 396.88 2 3
5 13 59.48 20 15.12 366 111 2.34 / 396.99 2 3
6 8 0.04 165 15.08 283 704 3.05 / 397.69 2 9
Average= 3.62
(KJ/cycle)

Cycle 108 GMT 5/ 5/2024 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 33 15.04 442 219 0.22 / 391.76 2 2
2 7 1197.40 42 15.06 1824 1154 1.37 / 392.91 2 3
3 13 1099.52 20 15.04 1721 518 1.89 / 393.43 2 3
4 13 689.32 20 15.05 1207 363 2.25 / 393.79 2 3
5 13 113.76 20 15.11 444 134 2.39 / 393.93 2 2
6 8 0.04 165 15.09 288 717 3.11 / 394.64 2 10
Average= 3.62
(KJ/cycle)

Cycle 107 GMT 25/ 4/2024 16: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 33 15.04 447 222 0.22 / 388.90 2 2
2 7 1069.60 41 15.11 1647 1020 1.24 / 389.92 2 5
3 13 993.64 20 15.08 1560 470 1.71 / 390.39 2 4
4 13 578.68 20 15.10 1063 321 2.03 / 390.71 2 2
5 13 59.28 20 15.14 373 113 2.15 / 390.82 2 3
6 8 0.12 165 15.11 288 718 2.86 / 391.54 2 7
Average= 3.63
(KJ/cycle)

Cycle 106 GMT 15/ 4/2024 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 33 15.03 429 213 0.21 / 386.00 2 2
2 7 1087.28 41 15.11 1668 1033 1.25 / 387.03 2 5
3 13 1007.36 20 15.08 1579 476 1.72 / 387.51 2 4
4 13 594.36 20 15.10 1076 325 2.05 / 387.83 2 3
5 13 70.12 20 15.14 388 117 2.16 / 387.95 2 2
6 8 0.28 165 15.10 291 725 2.89 / 388.67 2 4
Average= 3.63
(KJ/cycle)

Cycle 105 GMT 5/ 4/2024 18:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 33 15.05 445 221 0.22 / 383.02 2 2
2 7 1143.36 42 15.09 1729 1096 1.32 / 384.11 2 3
3 13 1044.92 20 15.07 1620 488 1.81 / 384.60 2 3
4 13 633.96 20 15.08 1120 338 2.14 / 384.94 2 3
5 13 83.64 20 15.13 408 123 2.27 / 385.06 2 3
6 8 0.16 165 15.10 289 720 2.99 / 385.78 2 7
Average= 3.64
(KJ/cycle)

Cycle 104 GMT 26/ 3/2024 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 33 15.01 454 225 0.22 / 380.11 2 2
2 7 1094.04 41 15.11 1677 1039 1.26 / 381.15 2 3
3 13 1014.20 20 15.10 1582 478 1.74 / 381.62 2 3
4 13 732.52 20 15.10 1236 373 2.11 / 382.00 2 3
5 13 127.96 20 15.15 440 133 2.25 / 382.13 2 2
6 8 0.00 165 15.12 267 666 2.91 / 382.80 2 7
Average= 3.65
(KJ/cycle)

Cycle 103 GMT 16/ 3/2024 20:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 32 15.03 441 212 0.21 / 376.89 2 2
2 3 1020.76 1 15.17 1667 25 0.24 / 376.91 2 3
3 7 1306.24 42 15.03 1942 1226 1.46 / 378.14 2 2
4 13 1191.04 20 15.02 1803 542 2.00 / 378.68 2 3
5 13 634.96 20 15.05 1160 349 2.35 / 379.03 2 3
6 13 85.16 20 15.11 420 127 2.48 / 379.16 2 2
7 8 0.08 165 15.08 292 727 3.21 / 379.88 2 10
Average= 3.65
(KJ/cycle)

Cycle 102 GMT 6/ 3/2024 21:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 15.02 422 190 0.19 / 373.69 2 2
2 10 1035.96 2 15.07 1643 50 0.24 / 373.74 2 3
3 3 1042.80 1 15.11 1674 25 0.26 / 373.77 2 2
4 7 1235.68 42 15.08 1858 1177 1.44 / 374.94 2 3
5 13 1139.40 20 15.06 1746 526 1.97 / 375.47 2 3
6 13 723.68 20 15.06 1256 378 2.35 / 375.85 2 4
7 13 59.92 20 15.14 353 107 2.45 / 375.95 2 3
8 8 0.04 165 15.10 290 723 3.18 / 376.68 2 4
Average= 3.66
(KJ/cycle)

Cycle 101 GMT 25/ 2/2024 22:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1002.40 10 14.95 1620 242 0.24 / 369.60 2 2
2 10 1134.24 8 14.92 1784 213 0.46 / 369.82 2 2
3 10 1228.80 6 14.91 1915 171 0.63 / 369.99 2 3
4 10 1261.60 2 14.93 1956 58 0.68 / 370.05 2 3
5 3 1264.12 7 14.96 1995 209 0.89 / 370.26 2 2
6 3 1115.56 3 15.05 1807 82 0.98 / 370.34 2 3
7 7 1486.04 41 14.98 2169 1332 2.31 / 371.67 2 3
8 13 1356.28 20 14.97 2040 611 2.92 / 372.28 2 4
9 13 777.20 20 15.01 1322 397 3.32 / 372.68 2 3
10 13 58.48 20 15.11 368 111 3.43 / 372.79 2 2
11 8 0.24 165 15.08 286 712 4.14 / 373.50 2 6
Average= 3.66
(KJ/cycle)

Cycle 100 GMT 15/ 2/2024 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 16 15.11 446 108 0.11 / 366.55 2 2
2 3 622.76 -7 15.40 0 0 0.00 / 366.55 2 2
3 3 623.12 -7 15.43 0 0 0.00 / 366.55 2 2
4 7 1175.20 41 15.08 1785 1104 1.21 / 367.66 2 3
5 13 1065.08 20 15.06 1676 505 1.72 / 368.16 2 3
6 13 685.40 20 15.06 1203 362 2.08 / 368.52 2 3
7 13 51.60 20 15.12 368 111 2.19 / 368.64 2 4
8 8 0.28 165 15.08 292 727 2.92 / 369.36 2 6
Average= 3.66
(KJ/cycle)

Cycle 99 GMT 5/ 2/2024 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 27 15.05 453 184 0.18 / 364.08 2 2
2 3 866.24 -3 15.39 0 0 0.00 / 364.08 2 2
3 3 866.80 -3 15.43 0 0 0.00 / 364.08 2 2
4 7 858.60 41 15.19 1405 875 1.06 / 364.95 2 2
5 13 787.16 20 15.17 1332 404 1.46 / 365.36 2 3
6 13 409.56 20 15.18 845 257 1.72 / 365.61 2 2
7 13 34.24 20 15.20 344 105 1.82 / 365.72 2 3
8 8 0.24 165 15.16 291 728 2.55 / 366.45 2 3
Average= 3.66
(KJ/cycle)

Cycle 98 GMT 27/ 1/2024 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 32 15.08 436 210 0.21 / 361.09 2 2
2 3 823.12 -3 15.41 0 0 0.00 / 361.09 2 2
3 3 958.96 -1 15.42 0 0 0.00 / 361.09 2 2
4 7 1206.12 41 15.07 1833 1133 1.34 / 362.22 2 2
5 13 1096.80 20 15.05 1728 520 1.86 / 362.74 2 3
6 13 536.32 20 15.09 1014 306 2.17 / 363.05 2 3
7 13 52.80 20 15.14 369 112 2.28 / 363.16 2 2
8 8 -0.16 165 15.10 294 733 3.01 / 363.89 2 7
Average= 3.68
(KJ/cycle)

Cycle 97 GMT 17/ 1/2024 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 15.03 422 203 0.20 / 358.40 2 2
2 10 1000.88 2 15.06 1595 48 0.25 / 358.45 2 3
3 3 953.88 -1 15.41 0 0 0.05 / 358.45 2 3
4 7 913.84 41 15.19 1447 901 1.15 / 359.35 2 2
5 13 863.08 20 15.16 1402 425 1.58 / 359.78 2 3
6 13 438.68 20 15.18 880 267 1.84 / 360.05 2 2
7 13 59.92 20 15.19 377 115 1.96 / 360.16 2 2
8 8 -0.08 165 15.16 288 720 2.68 / 360.88 2 7
Average= 3.68
(KJ/cycle)

Cycle 96 GMT 7/ 1/2024 3: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 15.07 442 213 0.21 / 355.17 2 2
2 7 1105.80 41 15.11 1705 1056 1.27 / 356.23 2 2
3 13 1022.04 20 15.08 1617 488 1.76 / 356.71 2 3
4 13 619.12 20 15.09 1123 339 2.10 / 357.05 2 3
5 13 42.20 20 15.16 350 106 2.20 / 357.16 2 3
6 8 0.28 165 15.12 288 719 2.92 / 357.88 2 9
7 14 0.28 75 15.08 286 323 3.24 / 358.20 2 11
Average= 3.69
(KJ/cycle)

Cycle 95 GMT 28/12/2023 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 31 15.07 447 209 0.21 / 352.37 2 2
2 10 1014.68 2 15.07 1621 49 0.26 / 352.42 2 2
3 7 993.56 42 15.15 1563 995 1.25 / 353.42 2 2
4 13 922.40 20 15.13 1499 454 1.71 / 353.87 2 5
5 13 395.48 20 15.15 831 252 1.96 / 354.12 2 2
6 13 48.20 20 15.18 366 111 2.07 / 354.23 2 2
7 8 0.08 165 15.14 290 724 2.79 / 354.96 2 10
Average= 3.70
(KJ/cycle)

Cycle 94 GMT 18/12/2023 5:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 25 15.07 445 168 0.17 / 349.28 2 2
2 10 1088.08 4 15.03 1742 105 0.27 / 349.38 2 2
3 3 1129.04 4 15.08 1818 110 0.38 / 349.49 2 2
4 7 1045.24 41 15.13 1644 1020 1.40 / 350.51 2 3
5 13 983.04 20 15.10 1582 478 1.88 / 350.99 2 2
6 13 592.72 20 15.12 1088 329 2.21 / 351.32 2 3
7 13 71.40 20 15.17 395 120 2.33 / 351.44 2 2
8 8 0.12 165 15.13 291 726 3.05 / 352.16 2 5
Average= 3.71
(KJ/cycle)

Cycle 93 GMT 8/12/2023 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 31 15.08 450 210 0.21 / 346.37 2 2
2 3 913.08 -2 15.42 0 0 0.00 / 346.37 2 2
3 3 912.84 -2 15.44 0 0 0.00 / 346.37 2 2
4 7 1144.52 41 15.10 1742 1078 1.29 / 347.45 2 5
5 13 1037.92 20 15.09 1612 487 1.78 / 347.93 2 5
6 13 623.88 20 15.11 1095 331 2.11 / 348.27 2 3
7 13 69.24 20 15.17 361 110 2.22 / 348.37 2 2
8 8 0.24 165 15.13 294 734 2.95 / 349.11 2 6
Average= 3.71
(KJ/cycle)

Cycle 92 GMT 28/11/2023 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 31 15.08 447 209 0.21 / 343.40 2 2
2 10 1002.08 2 15.10 1631 49 0.26 / 343.45 2 4
3 3 971.96 -1 15.41 0 0 0.05 / 343.45 2 4
4 3 1018.08 1 15.20 1645 25 0.28 / 343.47 2 3
5 7 1021.80 42 15.14 1600 1017 1.30 / 344.49 2 4
6 13 948.80 20 15.12 1532 463 1.76 / 344.95 2 4
7 13 685.88 20 15.11 1207 365 2.13 / 345.32 2 3
8 13 44.36 20 15.18 355 108 2.24 / 345.43 2 3
9 8 0.16 165 15.14 293 732 2.97 / 346.16 2 6
Average= 3.72
(KJ/cycle)

Cycle 91 GMT 18/11/2023 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 21 15.08 454 144 0.14 / 340.29 2 2
2 10 1004.28 5 15.05 1613 121 0.27 / 340.41 2 2
3 10 1057.16 3 15.05 1710 77 0.34 / 340.49 2 2
4 3 1138.68 4 15.07 1831 110 0.45 / 340.60 2 2
5 7 1036.80 41 15.13 1642 1019 1.47 / 341.62 2 2
6 13 961.12 20 15.11 1565 473 1.94 / 342.09 2 3
7 13 696.28 20 15.11 1231 372 2.32 / 342.46 2 4
8 8 0.20 165 15.15 291 727 3.04 / 343.19 2 3
Average= 3.73
(KJ/cycle)

Cycle 90 GMT 8/11/2023 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 21 15.05 441 139 0.14 / 337.41 2 2
2 7 1127.04 41 15.11 1717 1064 1.20 / 338.47 2 4
3 13 1033.44 20 15.10 1619 489 1.69 / 338.96 2 6
4 13 617.48 20 15.11 1118 338 2.03 / 339.30 2 3
5 13 77.40 20 15.18 403 122 2.15 / 339.42 2 3
6 8 0.16 165 15.14 291 727 2.88 / 340.15 2 6
Average= 3.74
(KJ/cycle)

Cycle 89 GMT 29/10/2023 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 32 15.07 436 210 0.21 / 334.13 2 2
2 3 821.96 -3 15.42 0 0 0.00 / 334.13 2 2
3 3 822.68 -3 15.43 0 0 0.00 / 334.13 2 2
4 7 1181.20 41 15.08 1805 1116 1.33 / 335.24 2 3
5 13 1082.80 20 15.06 1700 512 1.84 / 335.75 2 5
6 13 634.52 20 15.09 1145 346 2.18 / 336.10 2 3
7 13 73.44 20 15.16 385 117 2.30 / 336.22 2 2
8 8 0.12 165 15.12 291 726 3.03 / 336.94 2 10
9 14 0.12 75 15.08 287 325 3.35 / 337.27 3 12
Average= 3.75
(KJ/cycle)

Cycle 88 GMT 19/10/2023 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.00 32 15.04 459 221 0.22 / 331.23 2 2
2 7 1089.08 41 15.13 1692 1050 1.27 / 332.28 2 5
3 13 995.04 20 15.10 1590 480 1.75 / 332.76 2 2
4 13 564.76 20 15.13 1042 315 2.07 / 333.07 2 3
5 13 50.40 20 15.19 361 110 2.18 / 333.18 2 3
6 8 -0.16 165 15.14 293 732 2.91 / 333.92 2 5
Average= 3.75
(KJ/cycle)

Cycle 87 GMT 9/10/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 32 15.12 459 222 0.22 / 328.05 2 2
2 7 1339.28 42 15.03 1997 1261 1.48 / 329.31 2 3
3 13 1070.96 20 15.03 1704 512 1.99 / 329.82 2 4
4 13 650.96 20 15.07 1176 354 2.35 / 330.18 2 3
5 13 38.84 20 15.13 356 108 2.46 / 330.28 2 4
6 8 0.08 165 15.11 291 726 3.18 / 331.01 2 11
Average= 3.76
(KJ/cycle)

Cycle 86 GMT 29/ 9/2023 14: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 15.03 454 218 0.22 / 325.54 2 2
2 7 919.84 41 15.21 1457 909 1.13 / 326.45 2 5
3 13 871.52 20 15.19 1406 427 1.55 / 326.88 2 3
4 13 349.80 20 15.21 731 222 1.78 / 327.10 2 2
5 8 0.16 165 15.20 289 725 2.50 / 327.83 2 4
Average= 3.77
(KJ/cycle)

Cycle 85 GMT 19/ 9/2023 15:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 32 15.06 448 216 0.22 / 322.20 2 2
2 7 1516.20 41 14.97 2186 1342 1.56 / 323.55 2 3
3 13 1251.00 20 14.99 1923 577 2.13 / 324.12 2 3
4 13 674.16 20 15.03 1211 364 2.50 / 324.49 2 3
5 13 41.28 20 15.13 342 103 2.60 / 324.59 2 3
6 8 0.04 165 15.10 295 735 3.34 / 325.33 2 8
Average= 3.78
(KJ/cycle)

Cycle 84 GMT 9/ 9/2023 15:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 32 15.04 438 211 0.21 / 319.06 2 2
2 7 1489.76 41 14.99 2153 1323 1.53 / 320.38 2 3
3 13 1232.48 20 15.00 1862 559 2.09 / 320.94 2 4
4 13 544.04 20 15.07 1026 309 2.40 / 321.25 2 3
5 8 0.08 165 15.11 297 740 3.14 / 321.99 2 5
Average= 3.79
(KJ/cycle)

Cycle 83 GMT 30/ 8/2023 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 32 15.04 444 214 0.21 / 315.34 2 2
2 7 1803.08 41 14.92 2518 1540 1.75 / 316.88 2 8
3 13 1496.00 20 14.93 2192 655 2.41 / 317.53 2 5
4 13 887.28 20 14.97 1469 440 2.85 / 317.97 2 2
5 13 122.24 20 15.11 464 140 2.99 / 318.11 2 3
6 8 0.12 165 15.09 294 732 3.72 / 318.85 2 6
Average= 3.80
(KJ/cycle)

Cycle 82 GMT 20/ 8/2023 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 32 15.03 447 215 0.21 / 311.70 2 2
2 7 1811.52 41 14.90 2556 1561 1.78 / 313.26 2 6
3 13 1279.28 20 14.94 1957 585 2.36 / 313.85 2 5
4 13 842.64 20 14.97 1417 424 2.79 / 314.27 2 2
5 13 52.72 20 15.12 379 115 2.90 / 314.39 2 2
6 8 -0.12 165 15.09 297 739 3.64 / 315.13 2 9
Average= 3.80
(KJ/cycle)

Cycle 81 GMT 10/ 8/2023 22:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 32 15.06 451 217 0.22 / 308.03 2 2
2 7 1812.60 42 14.92 2554 1600 1.82 / 309.63 2 5
3 13 1398.76 20 14.93 2096 626 2.44 / 310.25 2 4
4 13 688.52 20 15.01 1219 366 2.81 / 310.62 2 3
5 13 102.92 20 15.12 449 136 2.95 / 310.75 2 2
6 8 0.04 165 15.10 294 733 3.68 / 311.49 2 8
Average= 3.80
(KJ/cycle)

Cycle 80 GMT 1/ 8/2023 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 32 15.07 470 227 0.23 / 304.44 2 2
2 7 1806.12 41 14.92 2522 1543 1.77 / 305.98 2 3
3 13 1241.64 20 14.96 1889 565 2.33 / 306.55 2 4
4 13 712.48 20 15.01 1256 377 2.71 / 306.92 2 3
5 13 103.44 20 15.12 451 136 2.85 / 307.06 2 2
6 8 0.44 165 15.10 300 747 3.60 / 307.81 2 7
Average= 3.80
(KJ/cycle)

Cycle 79 GMT 22/ 7/2023 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 15.08 447 216 0.22 / 301.01 2 2
2 7 1530.96 41 15.00 2212 1360 1.58 / 302.37 2 4
3 13 1404.64 20 14.98 2095 628 2.20 / 303.00 2 4
4 13 668.16 20 15.05 1193 359 2.56 / 303.36 2 3
5 13 50.00 20 15.16 376 114 2.68 / 303.47 2 2
6 8 -0.16 165 15.12 298 743 3.42 / 304.21 2 7
Average= 3.80
(KJ/cycle)

Cycle 78 GMT 12/ 7/2023 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 15.05 447 215 0.22 / 297.57 2 2
2 7 1534.32 41 15.01 2211 1361 1.58 / 298.93 2 2
3 13 1312.76 20 15.00 1973 592 2.17 / 299.52 2 3
4 13 760.96 20 15.04 1317 396 2.56 / 299.91 2 5
5 13 69.88 20 15.16 402 122 2.69 / 300.04 2 3
6 8 0.36 165 15.12 303 756 3.44 / 300.79 2 6
Average= 3.81
(KJ/cycle)

Cycle 77 GMT 2/ 7/2023 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 31 15.06 435 203 0.20 / 293.59 2 2
2 7 1805.56 41 14.94 2521 1544 1.75 / 295.13 2 6
3 13 1376.52 20 14.96 2021 605 2.35 / 295.74 2 3
4 13 892.44 20 14.99 1449 434 2.79 / 296.17 2 3
5 13 108.96 20 15.14 424 128 2.91 / 296.30 2 3
6 8 0.12 165 15.12 286 714 3.63 / 297.02 2 9
7 14 0.12 75 15.08 296 335 3.96 / 297.35 2 15
Average= 3.81
(KJ/cycle)

Cycle 76 GMT 22/ 6/2023 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 32 15.10 444 215 0.21 / 289.89 2 2
2 10 1003.12 2 15.17 1626 49 0.26 / 289.94 2 3
3 3 956.56 -1 15.43 0 0 0.05 / 289.94 2 3
4 3 966.80 -1 15.48 0 0 0.05 / 289.94 2 3
5 7 1814.56 41 14.92 2564 1568 1.83 / 291.51 2 3
6 13 1407.52 20 14.94 2115 632 2.46 / 292.14 2 3
7 13 698.20 20 15.02 1238 372 2.84 / 292.51 2 3
8 13 106.28 20 15.14 451 137 2.97 / 292.65 2 3
9 8 -0.04 165 15.12 295 736 3.71 / 293.39 2 6
Average= 3.81
(KJ/cycle)

Cycle 75 GMT 12/ 6/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 32 15.09 443 214 0.21 / 286.54 2 2
2 7 1428.00 41 15.06 2104 1299 1.51 / 287.84 2 2
3 13 1298.12 20 15.03 1971 592 2.11 / 288.43 2 3
4 13 712.24 20 15.09 1257 379 2.48 / 288.81 2 3
5 13 118.96 20 15.17 466 141 2.63 / 288.95 2 2
6 8 0.00 165 15.15 291 727 3.35 / 289.68 2 10
Average= 3.81
(KJ/cycle)

Cycle 74 GMT 2/ 6/2023 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 32 15.08 465 224 0.22 / 283.08 2 2
2 7 1668.44 41 14.96 2385 1463 1.69 / 284.54 2 7
3 13 1277.80 20 14.99 1945 583 2.27 / 285.12 2 5
4 13 610.92 20 15.07 1121 338 2.61 / 285.46 2 3
5 13 96.20 20 15.15 440 133 2.74 / 285.59 2 2
6 8 0.00 165 15.13 293 731 3.47 / 286.33 2 7
Average= 3.82
(KJ/cycle)

Cycle 73 GMT 23/ 5/2023 13:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 32 15.13 449 217 0.22 / 279.55 2 2
2 7 1633.48 42 14.97 2323 1461 1.68 / 281.01 2 6
3 13 1367.96 20 14.97 2049 613 2.29 / 281.62 2 3
4 13 665.52 20 15.04 1197 360 2.65 / 281.98 2 3
5 13 109.84 20 15.14 458 139 2.79 / 282.12 2 3
6 8 -0.24 165 15.13 294 734 3.52 / 282.85 2 5
Average= 3.82
(KJ/cycle)

Cycle 72 GMT 13/ 5/2023 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 15.14 443 215 0.21 / 276.69 2 2
2 3 1022.28 1 15.24 1638 25 0.24 / 276.71 2 3
3 7 1026.48 41 15.18 1594 992 1.23 / 277.71 2 3
4 13 938.72 20 15.16 1519 461 1.69 / 278.17 2 3
5 13 532.48 20 15.18 1022 310 2.00 / 278.48 2 3
6 13 36.76 20 15.23 357 109 2.11 / 278.59 2 3
7 8 0.20 165 15.19 296 742 2.85 / 279.33 2 6
Average= 3.83
(KJ/cycle)

Cycle 71 GMT 3/ 5/2023 15:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 31 15.13 452 212 0.21 / 273.91 2 2
2 7 1026.48 41 15.18 1596 993 1.21 / 274.90 2 4
3 13 949.40 20 15.17 1508 458 1.66 / 275.36 2 4
4 13 429.12 20 15.20 846 257 1.92 / 275.62 2 2
5 13 47.44 20 15.23 348 106 2.03 / 275.72 2 3
6 8 -0.16 165 15.20 299 750 2.78 / 276.47 2 4
Average= 3.84
(KJ/cycle)

Cycle 70 GMT 23/ 4/2023 16:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 15.14 450 211 0.21 / 271.03 2 2
2 7 1061.84 41 15.16 1641 1020 1.23 / 272.05 2 5
3 13 984.92 20 15.14 1556 471 1.70 / 272.52 2 3
4 13 557.56 20 15.16 1054 320 2.02 / 272.84 2 3
5 13 72.64 20 15.22 402 122 2.14 / 272.96 2 2
6 8 0.20 165 15.19 293 734 2.88 / 273.70 2 7
Average= 3.85
(KJ/cycle)

Cycle 69 GMT 13/ 4/2023 17:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 15.11 435 204 0.20 / 268.16 2 2
2 7 1029.36 41 15.18 1628 1013 1.22 / 269.18 2 5
3 13 958.40 20 15.16 1556 472 1.69 / 269.65 2 5
4 13 567.12 20 15.17 1066 323 2.01 / 269.97 2 3
5 13 57.76 20 15.23 383 117 2.13 / 270.09 2 2
6 8 -0.08 165 15.20 292 732 2.86 / 270.82 2 6
Average= 3.87
(KJ/cycle)

Cycle 68 GMT 3/ 4/2023 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 32 15.08 436 210 0.21 / 265.04 2 2
2 10 1003.60 2 15.14 1642 50 0.26 / 265.09 2 3
3 3 956.64 -1 15.44 0 0 0.05 / 265.09 2 3
4 7 1176.84 41 15.13 1811 1123 1.38 / 266.21 2 3
5 13 1175.80 20 15.09 1827 551 1.93 / 266.76 2 6
6 13 627.20 20 15.13 1148 347 2.28 / 267.11 2 4
7 13 70.64 20 15.21 401 122 2.40 / 267.23 2 3
8 8 0.04 165 15.17 291 728 3.13 / 267.96 2 9
Average= 3.88
(KJ/cycle)

Cycle 67 GMT 24/ 3/2023 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 32 15.09 443 214 0.21 / 261.21 2 2
2 7 1819.20 41 14.94 2545 1559 1.77 / 262.77 2 5
3 13 1539.72 20 14.94 2254 673 2.45 / 263.45 2 5
4 13 1041.52 20 14.96 1668 499 2.95 / 263.95 2 3
5 13 105.88 20 15.15 454 138 3.08 / 264.08 2 2
6 8 -0.28 165 15.12 298 743 3.83 / 264.83 2 6
Average= 3.89
(KJ/cycle)

Cycle 66 GMT 14/ 3/2023 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 15.09 437 204 0.20 / 257.53 2 2
2 3 1030.92 1 15.19 1668 25 0.23 / 257.55 2 2
3 7 1810.44 41 14.94 2555 1565 1.79 / 259.12 2 5
4 13 1379.12 20 14.95 2073 620 2.41 / 259.74 2 5
5 13 765.04 20 15.02 1332 400 2.81 / 260.14 2 6
6 13 84.24 20 15.16 423 128 2.94 / 260.27 2 2
7 8 0.00 165 15.14 293 732 3.67 / 261.00 2 4
Average= 3.90
(KJ/cycle)

Cycle 65 GMT 5/ 3/2023 2:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 32 15.10 425 205 0.21 / 253.90 2 2
2 3 1020.16 1 15.21 1646 25 0.23 / 253.92 2 3
3 3 970.92 -1 15.49 1 0 0.03 / 253.92 2 3
4 7 1806.20 41 14.94 2552 1563 1.79 / 255.49 2 4
5 13 1245.68 20 14.97 1911 572 2.37 / 256.06 2 3
6 13 804.20 20 15.01 1376 413 2.78 / 256.47 2 3
7 13 73.64 20 15.16 406 123 2.90 / 256.59 2 3
8 8 -0.04 165 15.13 293 731 3.63 / 257.32 2 8
Average= 3.90
(KJ/cycle)

Cycle 64 GMT 23/ 2/2023 6:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 32 15.10 446 216 0.22 / 250.27 2 2
2 7 1804.92 41 14.95 2545 1560 1.78 / 251.83 2 7
3 13 1258.20 20 14.98 1929 578 2.35 / 252.41 2 2
4 13 837.28 20 15.01 1421 427 2.78 / 252.83 2 3
5 13 108.24 20 15.16 455 138 2.92 / 252.97 2 3
6 8 0.12 165 15.14 289 722 3.64 / 253.69 2 3
Average= 3.90
(KJ/cycle)

Cycle 63 GMT 13/ 2/2023 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 15.10 439 212 0.21 / 246.65 2 2
2 7 1807.84 41 14.95 2535 1554 1.77 / 248.20 2 5
3 13 1387.80 20 14.97 2087 625 2.39 / 248.83 2 4
4 13 671.84 20 15.06 1211 365 2.76 / 249.19 2 4
5 13 101.52 20 15.17 446 135 2.89 / 249.33 2 2
6 8 -0.08 165 15.15 290 725 3.62 / 250.05 2 8
Average= 3.91
(KJ/cycle)

Cycle 62 GMT 3/ 2/2023 13:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 32 15.10 442 214 0.21 / 243.04 2 2
2 7 1804.60 42 14.94 2556 1604 1.82 / 244.65 2 4
3 13 1249.72 20 14.98 1933 579 2.40 / 245.22 2 3
4 13 670.40 20 15.06 1202 362 2.76 / 245.59 2 3
5 13 51.44 20 15.18 377 114 2.87 / 245.70 2 2
6 8 -0.16 165 15.15 294 735 3.61 / 246.44 2 6
Average= 3.91
(KJ/cycle)

Cycle 61 GMT 24/ 1/2023 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 32 15.10 445 215 0.22 / 239.31 2 2
2 7 1815.24 41 14.95 2564 1572 1.79 / 240.88 2 3
3 13 1364.80 20 14.97 2058 616 2.40 / 241.50 2 3
4 13 887.84 20 15.01 1482 445 2.85 / 241.94 2 3
5 13 130.40 20 15.17 494 150 3.00 / 242.09 2 2
6 8 -0.04 165 15.15 294 735 3.73 / 242.83 2 6
Average= 3.92
(KJ/cycle)

Cycle 60 GMT 14/ 1/2023 20:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 15.11 447 216 0.22 / 235.64 2 2
2 7 1809.44 42 14.93 2562 1607 1.82 / 237.25 2 6
3 13 1375.88 20 14.96 2069 619 2.44 / 237.87 2 3
4 13 668.12 20 15.05 1199 361 2.80 / 238.23 2 3
5 13 98.12 20 15.17 440 133 2.94 / 238.36 2 3
6 8 0.16 165 15.15 294 735 3.67 / 239.10 2 6
Average= 3.92
(KJ/cycle)

Cycle 59 GMT 4/ 1/2023 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 32 15.11 448 217 0.22 / 232.01 2 2
2 7 1818.44 41 14.93 2541 1555 1.77 / 233.56 2 7
3 13 1396.28 20 14.96 2074 621 2.39 / 234.18 2 3
4 13 682.92 20 15.06 1210 364 2.76 / 234.55 2 4
5 13 110.12 20 15.18 458 139 2.90 / 234.69 2 2
6 8 -0.24 165 15.15 295 737 3.63 / 235.42 2 5
Average= 3.92
(KJ/cycle)

Cycle 58 GMT 26/12/2022 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 32 15.12 433 210 0.21 / 228.35 2 2
2 7 1805.76 41 14.96 2550 1564 1.77 / 229.91 2 5
3 13 1366.96 20 14.98 2066 619 2.39 / 230.53 2 3
4 13 679.52 20 15.07 1216 367 2.76 / 230.90 2 4
5 13 118.00 20 15.17 470 143 2.90 / 231.04 2 2
6 8 0.40 165 15.16 299 748 3.65 / 231.79 2 5
Average= 3.93
(KJ/cycle)

Cycle 57 GMT 16/12/2022 6:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 15.11 457 221 0.22 / 224.67 2 2
2 7 1811.12 41 14.94 2569 1574 1.79 / 226.25 2 6
3 13 1386.36 20 14.96 2092 626 2.42 / 226.87 2 3
4 13 790.56 20 15.03 1361 409 2.83 / 227.28 2 4
5 13 86.88 20 15.18 404 123 2.95 / 227.40 2 2
6 8 0.16 165 15.15 295 737 3.69 / 228.14 2 6
Average= 3.93
(KJ/cycle)

Cycle 56 GMT 6/12/2022 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 15.11 446 216 0.22 / 220.94 2 2
2 7 1809.16 41 14.95 2551 1564 1.78 / 222.51 2 5
3 13 1524.12 20 14.95 2248 672 2.45 / 223.18 2 3
4 13 769.60 20 15.05 1331 401 2.85 / 223.58 2 3
5 13 83.80 20 15.18 423 128 2.98 / 223.71 2 2
6 8 -0.08 165 15.16 297 743 3.72 / 224.45 2 5
Average= 3.94
(KJ/cycle)

Cycle 55 GMT 26/11/2022 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 32 15.11 448 217 0.22 / 217.35 2 2
2 7 1804.04 42 14.96 2522 1585 1.80 / 218.93 2 4
3 13 1247.84 20 15.00 1885 565 2.37 / 219.50 2 6
4 13 666.68 20 15.08 1166 352 2.72 / 219.85 2 3
5 13 94.08 20 15.18 436 132 2.85 / 219.98 2 2
6 8 0.08 165 15.16 298 745 3.60 / 220.73 2 7
Average= 3.94
(KJ/cycle)

Cycle 54 GMT 16/11/2022 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 32 15.11 445 215 0.22 / 213.72 2 2
2 7 1809.08 41 14.95 2558 1568 1.78 / 215.29 2 4
3 13 1379.16 20 14.97 2076 622 2.40 / 215.91 2 4
4 13 669.32 20 15.07 1196 360 2.77 / 216.27 2 3
5 13 105.40 20 15.17 446 135 2.90 / 216.40 2 3
6 8 -0.20 165 15.16 291 728 3.63 / 217.13 2 4
Average= 3.95
(KJ/cycle)

Cycle 53 GMT 6/11/2022 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 15.12 446 216 0.22 / 210.03 2 2
2 7 1807.48 41 14.96 2556 1568 1.78 / 211.60 2 8
3 13 1391.60 20 14.98 2085 625 2.41 / 212.23 2 2
4 13 803.00 20 15.05 1376 414 2.82 / 212.64 2 3
5 13 102.80 20 15.18 445 135 2.96 / 212.78 2 2
6 8 0.08 165 15.17 291 728 3.69 / 213.50 2 6
Average= 3.95
(KJ/cycle)

Cycle 52 GMT 28/10/2022 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 32 15.13 443 214 0.21 / 206.43 2 2
2 7 1805.84 41 14.95 2516 1542 1.76 / 207.97 2 4
3 13 1255.04 20 14.99 1909 572 2.33 / 208.54 2 4
4 13 800.52 20 15.04 1367 411 2.74 / 208.95 2 3
5 13 87.76 20 15.19 424 129 2.87 / 209.08 2 2
6 8 0.00 165 15.16 294 735 3.60 / 209.82 2 6
Average= 3.96
(KJ/cycle)

Cycle 51 GMT 18/10/2022 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 32 15.14 443 215 0.21 / 202.83 2 2
2 7 1810.96 41 14.97 2539 1558 1.77 / 204.39 2 7
3 13 1264.12 20 15.00 1937 581 2.35 / 204.97 2 6
4 13 702.72 20 15.08 1246 376 2.73 / 205.35 2 3
5 13 117.08 20 15.19 460 140 2.87 / 205.49 2 2
6 8 -0.04 165 15.18 290 726 3.60 / 206.21 2 6
Average= 3.97
(KJ/cycle)

Cycle 50 GMT 8/10/2022 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 15.13 457 221 0.22 / 199.21 2 2
2 7 1805.84 41 14.96 2546 1562 1.78 / 200.78 2 6
3 13 1270.52 20 14.99 1941 582 2.36 / 201.36 2 3
4 13 722.00 20 15.07 1260 380 2.74 / 201.74 2 4
5 13 131.08 20 15.18 485 147 2.89 / 201.88 2 2
6 8 0.36 165 15.17 293 733 3.63 / 202.62 2 7
Average= 3.97
(KJ/cycle)

Cycle 49 GMT 28/ 9/2022 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 32 15.13 452 219 0.22 / 195.52 2 2
2 7 1810.16 42 14.96 2550 1602 1.82 / 197.12 2 6
3 13 1368.36 20 14.99 2063 618 2.44 / 197.74 2 4
4 13 775.00 20 15.07 1325 399 2.84 / 198.14 2 3
5 13 72.28 20 15.21 400 122 2.96 / 198.26 2 2
6 8 -0.04 165 15.19 291 729 3.69 / 198.99 2 6
Average= 3.98
(KJ/cycle)

Cycle 48 GMT 18/ 9/2022 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 15.14 443 215 0.21 / 191.94 2 2
2 7 1806.68 41 14.98 2528 1553 1.77 / 193.49 2 3
3 13 1267.04 20 15.01 1910 573 2.34 / 194.06 2 4
4 13 712.56 20 15.08 1217 367 2.71 / 194.43 2 5
5 13 123.96 20 15.20 439 133 2.84 / 194.56 2 2
6 8 -0.08 165 15.18 295 739 3.58 / 195.30 2 4
Average= 3.99
(KJ/cycle)

Cycle 47 GMT 8/ 9/2022 17:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 15.15 444 215 0.22 / 188.33 2 2
2 7 1808.40 41 14.98 2536 1558 1.77 / 189.89 2 6
3 13 1260.20 20 15.01 1928 579 2.35 / 190.46 2 4
4 13 695.60 20 15.08 1228 370 2.72 / 190.83 2 3
5 13 108.88 20 15.21 463 141 2.86 / 190.98 2 2
6 8 0.08 165 15.19 298 747 3.61 / 191.72 2 5
Average= 3.99
(KJ/cycle)

Cycle 46 GMT 29/ 8/2022 20:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 32 15.15 445 216 0.22 / 184.76 2 2
2 7 1805.00 41 14.97 2514 1543 1.76 / 186.31 2 3
3 13 1265.28 20 15.00 1898 569 2.33 / 186.88 2 3
4 13 694.60 20 15.08 1228 370 2.70 / 187.25 2 3
5 13 56.44 20 15.22 383 117 2.82 / 187.36 2 3
6 8 0.20 165 15.19 299 749 3.56 / 188.11 2 5
Average= 4.00
(KJ/cycle)

Cycle 45 GMT 20/ 8/2022 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 31 15.14 452 212 0.21 / 181.14 2 2
2 7 1806.96 41 14.99 2507 1541 1.75 / 182.68 2 8
3 13 1376.72 20 15.01 2034 611 2.36 / 183.29 2 4
4 13 798.76 20 15.08 1329 401 2.76 / 183.69 2 3
5 13 81.12 20 15.23 385 117 2.88 / 183.81 2 3
6 8 0.16 165 15.20 295 740 3.62 / 184.55 2 9
Average= 4.01
(KJ/cycle)

Cycle 44 GMT 10/ 8/2022 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 31 15.16 452 212 0.21 / 177.51 2 2
2 7 1819.96 41 14.98 2545 1563 1.78 / 179.07 2 3
3 13 1286.68 20 15.00 1969 591 2.37 / 179.66 2 3
4 13 713.28 20 15.08 1258 379 2.75 / 180.04 2 3
5 13 116.16 20 15.20 455 138 2.88 / 180.18 2 2
6 8 -0.16 165 15.19 298 747 3.63 / 180.93 2 7
Average= 4.02
(KJ/cycle)

Cycle 43 GMT 31/ 7/2022 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.15 445 209 0.21 / 173.92 2 2
2 7 1804.84 41 14.98 2549 1566 1.77 / 175.49 2 5
3 13 1246.08 20 15.04 1915 576 2.35 / 176.07 2 2
4 13 676.76 20 15.11 1206 364 2.72 / 176.43 2 3
5 13 51.08 20 15.23 378 115 2.83 / 176.55 2 2
6 8 -0.12 165 15.21 299 750 3.58 / 177.30 2 6
Average= 4.03
(KJ/cycle)

Cycle 42 GMT 21/ 7/2022 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 15.15 460 216 0.22 / 170.32 2 2
2 7 1804.32 42 14.98 2514 1582 1.80 / 171.90 2 7
3 13 1266.68 20 15.04 1921 578 2.38 / 172.48 2 4
4 13 699.56 20 15.09 1240 374 2.75 / 172.85 2 3
5 13 55.36 20 15.23 389 118 2.87 / 172.97 2 2
6 8 0.28 165 15.20 298 747 3.62 / 173.72 2 4
Average= 4.04
(KJ/cycle)

Cycle 41 GMT 11/ 7/2022 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 31 15.15 450 211 0.21 / 166.67 2 2
2 7 1816.16 41 14.99 2535 1558 1.77 / 168.23 2 7
3 13 1269.08 20 15.03 1921 577 2.35 / 168.81 2 5
4 13 827.12 20 15.09 1370 413 2.76 / 169.22 2 6
5 13 88.92 20 15.24 402 123 2.88 / 169.34 2 3
6 8 -0.12 165 15.20 301 755 3.64 / 170.10 2 8
Average= 4.05
(KJ/cycle)

Cycle 40 GMT 1/ 7/2022 17: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 31 15.14 457 214 0.21 / 162.93 2 2
2 7 1815.56 42 14.98 2568 1616 1.83 / 164.54 2 6
3 13 1391.76 20 15.01 2077 624 2.45 / 165.16 2 3
4 13 789.80 20 15.08 1361 410 2.86 / 165.58 2 3
5 13 88.88 20 15.22 440 134 3.00 / 165.71 2 3
6 8 0.24 165 15.20 300 752 3.75 / 166.46 2 5
Average= 4.06
(KJ/cycle)

Cycle 39 GMT 21/ 6/2022 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 31 15.17 449 211 0.21 / 159.22 2 2
2 7 1820.40 41 14.97 2562 1572 1.78 / 160.79 2 7
3 13 1263.56 20 15.01 1939 582 2.37 / 161.37 2 3
4 13 817.84 20 15.08 1397 421 2.79 / 161.79 2 4
5 13 96.24 20 15.22 448 136 2.92 / 161.93 2 2
6 8 0.12 165 15.20 312 782 3.71 / 162.71 2 8
Average= 4.07
(KJ/cycle)

Cycle 38 GMT 11/ 6/2022 23:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 15.16 441 207 0.21 / 155.48 2 2
2 7 1806.12 41 14.99 2553 1569 1.78 / 157.05 2 5
3 13 1381.16 20 15.02 2070 622 2.40 / 157.68 2 5
4 13 787.16 20 15.10 1360 411 2.81 / 158.09 2 3
5 13 167.40 20 15.21 539 164 2.97 / 158.25 2 2
6 8 0.12 165 15.21 301 755 3.73 / 159.01 2 7
Average= 4.08
(KJ/cycle)

Cycle 37 GMT 2/ 6/2022 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 31 15.16 457 215 0.21 / 151.89 2 2
2 7 1804.64 41 15.00 2520 1550 1.76 / 153.44 2 6
3 13 1369.76 20 15.04 2025 609 2.37 / 154.05 2 4
4 13 660.68 20 15.14 1150 348 2.72 / 154.40 2 4
5 13 96.00 20 15.24 420 128 2.85 / 154.53 2 2
6 8 -0.24 165 15.22 298 748 3.60 / 155.28 2 4
Average= 4.09
(KJ/cycle)

Cycle 36 GMT 23/ 5/2022 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 31 15.17 457 215 0.21 / 148.24 2 2
2 7 1806.76 41 15.01 2525 1554 1.77 / 149.79 2 7
3 13 1371.08 20 15.03 2029 610 2.38 / 150.40 2 3
4 13 777.48 20 15.11 1340 405 2.78 / 150.81 2 3
5 13 83.20 20 15.24 426 130 2.91 / 150.94 2 2
6 8 -0.12 165 15.21 296 743 3.66 / 151.68 2 6
Average= 4.10
(KJ/cycle)

Cycle 35 GMT 13/ 5/2022 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 31 15.17 445 209 0.21 / 144.63 2 2
2 7 1811.12 41 15.01 2533 1559 1.77 / 146.19 2 4
3 13 1266.60 20 15.05 1904 573 2.34 / 146.77 2 3
4 13 706.24 20 15.12 1214 367 2.71 / 147.13 2 3
5 13 122.28 20 15.24 463 141 2.85 / 147.27 2 2
6 8 0.04 165 15.21 298 748 3.60 / 148.02 2 6
Average= 4.11
(KJ/cycle)

Cycle 34 GMT 3/ 5/2022 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 31 15.18 463 218 0.22 / 140.94 2 2
2 7 1815.00 42 14.99 2562 1613 1.83 / 142.55 2 2
3 13 1383.16 20 15.01 2083 625 2.46 / 143.18 2 4
4 13 651.48 20 15.13 1189 360 2.82 / 143.54 2 3
5 13 107.36 20 15.24 462 141 2.96 / 143.68 2 2
6 8 -0.16 165 15.22 297 746 3.70 / 144.43 2 5
Average= 4.13
(KJ/cycle)

Cycle 33 GMT 23/ 4/2022 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.18 433 204 0.20 / 137.32 2 2
2 7 1811.40 41 15.01 2538 1562 1.77 / 138.89 2 5
3 13 1242.64 20 15.05 1916 577 2.34 / 139.46 2 3
4 13 677.44 20 15.14 1220 369 2.71 / 139.83 2 3
5 13 100.80 20 15.24 452 138 2.85 / 139.97 2 2
6 8 -0.04 165 15.22 300 753 3.60 / 140.72 2 7
Average= 4.14
(KJ/cycle)

Cycle 32 GMT 13/ 4/2022 20:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 31 15.17 451 212 0.21 / 133.59 2 2
2 7 1813.96 41 15.00 2568 1579 1.79 / 135.17 2 4
3 13 1395.52 20 15.03 2101 632 2.42 / 135.81 2 4
4 13 785.28 20 15.12 1352 409 2.83 / 136.21 2 3
5 13 97.52 20 15.26 447 136 2.97 / 136.35 2 2
6 8 -0.12 165 15.23 306 769 3.74 / 137.12 2 5
Average= 4.16
(KJ/cycle)

Cycle 31 GMT 4/ 4/2022 0: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 31 15.18 453 213 0.21 / 129.94 2 2
2 7 1816.72 41 15.00 2558 1573 1.79 / 131.52 2 5
3 13 1248.84 20 15.04 1926 579 2.37 / 132.10 2 3
4 13 698.28 20 15.12 1247 377 2.74 / 132.47 2 5
5 13 114.12 20 15.24 458 140 2.88 / 132.61 2 3
6 8 0.00 165 15.22 306 768 3.65 / 133.38 2 5
Average= 4.17
(KJ/cycle)

Cycle 30 GMT 25/ 3/2022 3:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 31 15.16 438 206 0.21 / 126.31 2 2
2 7 1805.72 41 14.99 2554 1570 1.78 / 127.88 2 6
3 13 1245.80 20 15.03 1912 575 2.35 / 128.46 2 3
4 13 678.68 20 15.12 1226 371 2.72 / 128.83 2 3
5 13 102.92 20 15.24 455 139 2.86 / 128.97 2 2
6 8 0.12 165 15.22 304 763 3.62 / 129.73 2 8
Average= 4.18
(KJ/cycle)

Cycle 29 GMT 15/ 3/2022 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 31 15.20 456 215 0.21 / 122.69 2 2
2 7 1804.04 41 15.01 2536 1561 1.78 / 124.25 2 6
3 13 1233.12 20 15.05 1902 573 2.35 / 124.82 2 3
4 13 658.72 20 15.13 1191 360 2.71 / 125.19 2 3
5 13 95.48 20 15.25 441 135 2.84 / 125.32 2 2
6 8 0.12 165 15.22 314 789 3.63 / 126.11 2 5
Average= 4.20
(KJ/cycle)

Cycle 28 GMT 5/ 3/2022 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 31 15.19 459 216 0.22 / 119.04 2 2
2 7 1807.56 41 15.01 2553 1571 1.79 / 120.61 2 6
3 13 1237.08 20 15.06 1908 575 2.36 / 121.19 2 3
4 13 678.84 20 15.14 1221 370 2.73 / 121.56 2 3
5 13 98.64 20 15.26 448 137 2.87 / 121.69 2 2
6 8 0.00 165 15.23 312 784 3.65 / 122.48 2 5
Average= 4.22
(KJ/cycle)

Cycle 27 GMT 23/ 2/2022 13:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 15.23 456 215 0.22 / 115.33 2 2
2 7 1807.48 41 15.01 2564 1578 1.79 / 116.90 2 5
3 13 1375.60 20 15.02 2076 624 2.42 / 117.53 2 2
4 13 763.88 20 15.14 1328 402 2.82 / 117.93 2 3
5 13 83.72 20 15.26 425 130 2.95 / 118.06 2 2
6 8 0.08 165 15.25 304 765 3.71 / 118.82 2 4
Average= 4.24
(KJ/cycle)

Cycle 26 GMT 13/ 2/2022 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 31 15.21 465 219 0.22 / 112.15 2 2
2 3 1021.64 1 15.30 1651 25 0.24 / 112.17 2 2
3 7 1260.76 41 15.18 1897 1181 1.43 / 113.35 2 6
4 13 1144.24 20 15.17 1785 542 1.97 / 113.89 2 3
5 13 579.28 20 15.23 1082 330 2.30 / 114.22 2 3
6 13 66.08 20 15.31 395 121 2.42 / 114.34 2 2
7 8 0.08 165 15.28 304 766 3.18 / 115.11 2 5
Average= 4.26
(KJ/cycle)

Cycle 25 GMT 3/ 2/2022 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 30 15.19 466 212 0.21 / 108.69 2 2
2 3 1040.84 1 15.28 1691 26 0.24 / 108.71 2 2
3 3 1016.52 1 15.33 1656 25 0.26 / 108.74 2 2
4 7 1512.88 41 15.09 2200 1361 1.62 / 110.10 2 5
5 13 1260.28 20 15.09 1929 582 2.21 / 110.68 2 5
6 13 667.96 20 15.17 1203 365 2.57 / 111.05 2 3
7 13 95.72 20 15.27 435 133 2.70 / 111.18 2 2
8 8 0.08 165 15.24 297 747 3.45 / 111.93 2 4
Average= 4.30
(KJ/cycle)

Cycle 24 GMT 24/ 1/2022 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 16 15.24 459 112 0.11 / 104.56 2 2
2 10 1027.40 7 15.20 1672 178 0.29 / 104.74 2 2
3 10 1083.72 4 15.21 1754 107 0.40 / 104.84 2 4
4 10 1134.72 3 15.19 1826 83 0.48 / 104.93 2 3
5 3 1109.12 3 15.24 1789 82 0.56 / 105.01 2 4
6 3 1017.32 1 15.33 1656 25 0.59 / 105.03 2 2
7 7 1797.40 41 15.00 2538 1561 2.15 / 106.59 2 4
8 13 1354.00 20 15.05 2053 618 2.77 / 107.21 2 6
9 13 635.80 20 15.16 1163 353 3.12 / 107.56 2 3
10 13 90.88 20 15.27 430 131 3.25 / 107.70 2 2
11 8 0.20 165 15.24 310 780 4.03 / 108.48 2 6
Average= 4.34
(KJ/cycle)

Cycle 23 GMT 14/ 1/2022 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1039.28 11 15.06 344 57 0.06 / 101.01 247 168
2 2 1039.28 25 15.08 286 108 0.16 / 101.11 152 8
3 2 225.28 13 15.24 304 60 0.23 / 101.17 2 2
4 10 1021.24 3 15.18 1331 61 0.29 / 101.23 2 2
5 3 1028.16 1 15.27 1447 22 0.31 / 101.26 2 2
6 7 1222.88 41 15.53 575 366 0.67 / 101.62 2 2
7 13 1221.76 20 15.27 1736 530 1.20 / 102.15 2 3
8 13 1221.68 20 15.20 1855 564 1.77 / 102.72 2 2
9 13 1183.44 20 15.15 1831 555 2.32 / 103.27 2 7
10 13 467.24 20 15.25 934 285 2.61 / 103.56 2 2
11 13 40.20 20 15.31 365 112 2.72 / 103.67 2 2
12 8 0.36 165 15.27 309 779 3.50 / 104.45 2 5
Average= 4.35
(KJ/cycle)

Cycle 22

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1039.96 11 15.08 269 45 0.04 / 86.57 247 247
2 2 1039.96 23 15.01 533 184 0.23 / 86.76 247 178
3 3 1039.48 1 15.19 1648 25 0.25 / 86.78 17 99
4 3 1039.32 1 15.25 1338 20 0.27 / 86.80 89 155
5 7 1039.76 42 15.43 1110 719 0.99 / 87.52 2 2
6 13 1038.92 20 15.32 1510 463 1.46 / 87.99 2 4
7 13 1039.00 20 15.28 1479 452 1.91 / 88.44 2 3
8 13 1039.08 20 15.23 1456 443 2.35 / 88.88 2 4
9 13 1039.20 20 15.16 1564 474 2.83 / 89.36 2 6
10 13 1039.28 20 15.13 1536 465 3.29 / 89.82 2 4
11 13 1039.32 20 15.09 1582 477 3.77 / 90.30 2 6
12 13 1039.44 20 15.05 1564 471 4.24 / 90.77 2 6
13 13 1039.48 20 15.02 1576 473 4.71 / 91.24 2 4
14 13 1039.48 20 15.00 1548 464 5.18 / 91.71 2 4
15 13 1039.52 20 14.97 1602 480 5.66 / 92.19 2 4
16 13 1039.56 20 14.95 1580 472 6.13 / 92.66 2 4
17 13 1039.56 20 14.92 1635 488 6.62 / 93.15 2 8
18 13 1039.52 20 14.91 1631 486 7.10 / 93.63 2 7
19 13 1039.52 20 14.89 1599 476 7.58 / 94.11 2 7
20 13 1039.40 20 14.87 1644 489 8.07 / 94.60 2 9
21 13 1039.36 20 14.87 1633 486 8.55 / 95.08 2 8
22 13 1039.28 20 14.86 1617 481 9.03 / 95.56 2 8
23 13 1039.16 20 14.85 1617 480 9.51 / 96.04 2 12
24 13 1039.08 20 14.84 1622 481 10.00 / 96.53 2 12
25 13 1039.00 20 14.83 1630 483 10.48 / 97.01 2 13
26 13 1038.88 20 14.82 1630 483 10.96 / 97.49 3 13
27 13 1038.76 20 14.81 1633 484 11.45 / 97.98 3 12
28 13 1038.68 20 14.80 1624 481 11.93 / 98.46 4 16
29 13 1038.56 20 14.86 1265 376 12.30 / 98.83 6 33
30 13 1038.40 20 14.98 591 177 12.48 / 99.01 10 23
31 13 1038.32 20 15.01 486 146 12.63 / 99.16 12 12
32 13 1038.24 20 15.04 341 103 12.73 / 99.26 12 14
33 13 1038.16 20 15.06 379 114 12.84 / 99.37 13 20
34 13 1038.08 20 15.05 411 124 12.97 / 99.50 13 19
35 13 1039.00 20 15.06 370 111 13.08 / 99.61 13 18
36 13 1038.92 20 15.07 393 118 13.20 / 99.73 13 23
37 13 1038.92 20 15.11 315 95 13.29 / 99.82 14 20
38 13 1038.92 20 15.10 417 126 13.42 / 99.95 14 29
39 13 1038.92 20 15.14 311 94 13.51 / 100.04 15 27
40 13 1038.96 20 15.13 372 113 13.62 / 100.15 15 38
41 13 1039.00 20 15.15 310 94 13.72 / 100.25 16 31
42 8 1039.00 165 15.11 281 701 14.42 / 100.95 28 20
Average= 4.39
(KJ/cycle)

Cycle 21

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 15.28 476 211 0.21 / 72.27 2 2
2 3 903.12 -2 15.56 0 0 0.00 / 72.27 2 2
3 3 907.84 -2 15.58 0 0 0.00 / 72.27 2 2
4 7 1040.56 41 15.28 1665 1043 1.25 / 73.31 2 4
5 13 1039.64 20 15.24 1678 511 1.77 / 73.82 2 3
6 13 1039.60 20 15.18 1673 508 2.27 / 74.33 2 5
7 13 1039.60 20 15.13 1674 507 2.78 / 74.84 2 7
8 13 1039.60 20 15.08 1678 506 3.29 / 75.35 2 3
9 13 1039.64 20 15.05 1671 503 3.79 / 75.85 2 5
10 13 1039.60 20 15.02 1677 504 4.29 / 76.35 2 7
11 13 1039.56 20 14.98 1674 502 4.79 / 76.85 2 4
12 13 1039.44 20 14.95 1681 503 5.30 / 77.36 2 7
13 13 1039.44 20 14.92 1683 502 5.80 / 77.86 2 4
14 13 1039.36 20 14.90 1676 499 6.30 / 78.36 2 8
15 13 1039.32 20 14.89 1672 498 6.80 / 78.86 2 7
16 13 1039.24 20 14.88 1680 500 7.30 / 79.36 2 10
17 13 1039.16 20 14.86 1675 498 7.79 / 79.85 2 8
18 13 1039.04 20 14.85 1674 497 8.29 / 80.35 2 10
19 13 1039.00 20 14.84 1677 498 8.79 / 80.85 2 10
20 13 1038.84 20 14.81 1674 496 9.29 / 81.34 2 12
21 13 1038.80 20 14.81 1672 495 9.78 / 81.84 3 11
22 13 1038.72 20 14.81 1673 496 10.28 / 82.34 3 14
23 13 1038.64 20 14.81 1668 494 10.77 / 82.83 3 15
24 13 1038.56 20 14.80 1669 494 11.26 / 83.32 4 17
25 13 1038.48 20 14.78 1669 493 11.76 / 83.82 6 247
26 13 1038.48 20 14.86 1269 377 12.13 / 84.19 247 247
27 13 1038.44 20 15.00 442 133 12.27 / 84.33 247 138
28 13 1038.44 20 15.01 476 143 12.41 / 84.47 16 104
29 13 1038.40 20 14.99 552 165 12.58 / 84.63 18 55
30 13 1038.40 20 15.03 437 131 12.71 / 84.77 19 57
31 13 1038.36 20 15.02 461 138 12.85 / 84.90 19 54
32 13 1038.40 20 15.06 320 96 12.94 / 85.00 20 39
33 13 1038.40 20 15.04 424 128 13.07 / 85.13 21 46
34 13 1039.40 20 15.08 303 91 13.16 / 85.22 21 34
35 13 1039.44 20 15.08 382 115 13.28 / 85.34 21 49
36 13 1039.48 20 15.11 300 91 13.37 / 85.43 33 32
37 13 1039.52 20 15.10 341 103 13.47 / 85.53 22 38
38 13 1039.60 20 15.12 323 98 13.57 / 85.63 26 50
39 13 1039.68 20 15.13 362 110 13.68 / 85.74 46 50
40 13 1039.72 20 15.16 306 93 13.77 / 85.83 49 48
41 8 1039.72 165 15.12 281 701 14.47 / 86.53 47 49
Average= 3.93
(KJ/cycle)

Cycle 20 GMT 15/12/2021 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 29 15.26 485 215 0.21 / 69.54 2 2
2 7 945.56 41 15.32 1533 963 1.18 / 70.50 2 5
3 13 870.24 20 15.31 1470 450 1.63 / 70.95 2 4
4 13 455.44 20 15.32 934 286 1.91 / 71.24 2 2
5 8 0.08 165 15.34 325 823 2.74 / 72.06 2 6
Average= 3.43
(KJ/cycle)

Cycle 19 GMT 5/12/2021 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 29 15.24 483 213 0.21 / 66.47 2 2
2 7 1086.16 41 15.26 1720 1076 1.29 / 67.54 2 3
3 13 992.68 20 15.25 1626 496 1.79 / 68.04 2 3
4 13 578.80 20 15.28 1101 336 2.12 / 68.37 2 3
5 13 25.08 20 15.36 366 112 2.23 / 68.49 2 2
6 8 0.00 165 15.32 331 837 3.07 / 69.32 2 7
Average= 3.47
(KJ/cycle)

Cycle 18 GMT 25/11/2021 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.22 483 213 0.21 / 63.01 2 2
2 7 1462.56 41 15.13 2181 1353 1.57 / 64.36 2 3
3 13 1193.88 20 15.16 1871 567 2.13 / 64.93 2 2
4 13 619.80 20 15.24 1165 355 2.49 / 65.28 2 2
5 13 29.00 20 15.34 371 114 2.60 / 65.40 2 2
6 8 -0.08 165 15.29 339 855 3.46 / 66.25 2 9
Average= 3.49
(KJ/cycle)

Cycle 17 GMT 15/11/2021 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 30 15.22 496 226 0.23 / 59.14 2 2
2 7 1807.16 41 15.05 2603 1606 1.83 / 60.74 2 2
3 13 1374.16 20 15.08 2114 638 2.47 / 61.38 2 2
4 13 764.60 20 15.17 1351 410 2.88 / 61.79 2 2
5 13 130.84 20 15.29 514 157 3.04 / 61.95 2 2
6 8 0.00 165 15.26 336 846 3.88 / 62.79 2 4
Average= 3.49
(KJ/cycle)

Cycle 16 GMT 5/11/2021 10: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 15.24 486 222 0.22 / 55.27 2 2
2 7 1806.76 41 15.05 2586 1596 1.82 / 56.87 2 3
3 13 1384.08 20 15.07 2114 637 2.46 / 57.50 2 3
4 13 768.16 20 15.16 1354 411 2.87 / 57.91 2 3
5 13 65.16 20 15.30 428 131 3.00 / 58.04 2 2
6 8 0.00 165 15.27 344 867 3.86 / 58.91 2 5
Average= 3.47
(KJ/cycle)

Cycle 15 GMT 26/10/2021 13:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 15.24 478 211 0.21 / 51.53 2 2
2 7 1815.92 42 15.02 2612 1648 1.86 / 53.17 2 2
3 13 1352.16 20 15.08 2073 625 2.48 / 53.80 2 2
4 13 734.16 20 15.19 1302 396 2.88 / 54.20 2 2
5 8 0.08 165 15.29 338 853 3.73 / 55.05 2 6
Average= 3.44
(KJ/cycle)

Cycle 14 GMT 16/10/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.26 481 213 0.21 / 47.85 2 2
2 7 1639.36 41 15.08 2405 1487 1.70 / 49.33 2 2
3 13 1241.20 20 15.12 1939 586 2.29 / 49.92 2 2
4 13 812.08 20 15.17 1411 428 2.71 / 50.35 2 2
5 13 65.00 20 15.31 427 131 2.85 / 50.48 2 2
6 8 0.00 165 15.29 332 838 3.68 / 51.32 2 4
Average= 3.42
(KJ/cycle)

Cycle 13 GMT 6/10/2021 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 15.25 480 212 0.21 / 44.21 2 2
2 7 1596.32 41 15.10 2362 1462 1.67 / 45.67 2 2
3 13 1333.80 19 15.11 2057 591 2.27 / 46.26 2 2
4 13 729.24 19 15.21 1305 377 2.64 / 46.64 2 2
5 13 129.48 19 15.32 514 150 2.79 / 46.79 2 2
6 8 0.00 165 15.31 335 846 3.64 / 47.63 2 8
Average= 3.40
(KJ/cycle)

Cycle 12 GMT 26/ 9/2021 17:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 15.25 487 215 0.22 / 40.51 2 2
2 3 1020.32 1 15.33 1699 26 0.24 / 40.54 2 2
3 7 1707.88 42 15.06 2494 1578 1.82 / 42.12 2 2
4 13 1270.00 19 15.10 1987 570 2.39 / 42.69 2 2
5 13 674.20 19 15.21 1233 356 2.75 / 43.04 2 2
6 13 21.20 19 15.34 363 106 2.85 / 43.15 2 2
7 8 0.32 165 15.30 335 846 3.70 / 43.99 2 7
Average= 3.38
(KJ/cycle)

Cycle 11 GMT 16/ 9/2021 17:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 15.25 479 212 0.21 / 36.84 2 2
2 7 1791.24 41 15.03 2585 1593 1.80 / 38.43 2 2
3 13 1232.76 19 15.12 1916 550 2.36 / 38.98 2 2
4 13 663.44 19 15.21 1213 351 2.71 / 39.33 2 2
5 13 84.32 19 15.32 448 130 2.84 / 39.47 2 2
6 8 0.00 165 15.29 330 833 3.67 / 40.30 2 6
Average= 3.36
(KJ/cycle)

Cycle 10 GMT 6/ 9/2021 17:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 29 15.25 474 210 0.21 / 33.11 2 2
2 7 1805.52 41 15.06 2591 1600 1.81 / 34.71 2 2
3 13 1370.68 19 15.10 2091 600 2.41 / 35.31 2 2
4 13 648.20 19 15.21 1194 345 2.75 / 35.65 2 2
5 13 95.80 19 15.32 469 137 2.89 / 35.79 2 2
6 8 -0.20 165 15.29 332 838 3.73 / 36.63 2 4
Average= 3.33
(KJ/cycle)

Cycle 9 GMT 27/ 8/2021 21:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 15.24 475 210 0.21 / 29.55 2 2
2 7 1809.80 44 15.04 2605 1724 1.93 / 31.27 2 2
3 13 1123.48 18 15.14 1796 489 2.42 / 31.76 2 2
4 13 581.28 18 15.23 1109 304 2.73 / 32.07 2 2
5 8 -0.04 165 15.30 330 833 3.56 / 32.90 2 5
Average= 3.29
(KJ/cycle)

Cycle 8 GMT 18/ 8/2021 0:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 28 15.24 495 211 0.21 / 25.56 2 2
2 3 1019.44 1 15.34 1674 26 0.24 / 25.59 2 2
3 7 1812.88 44 15.04 2589 1713 1.95 / 27.30 2 2
4 13 1219.92 18 15.12 1907 519 2.47 / 27.82 2 2
5 13 630.40 18 15.22 1184 324 2.79 / 28.14 2 2
6 8 0.28 165 15.30 327 826 3.62 / 28.97 2 8
7 14 0.28 75 15.27 324 371 3.99 / 29.34 2 9
Average= 3.26
(KJ/cycle)

Cycle 7 GMT 8/ 8/2021 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 15.27 465 199 0.20 / 21.67 2 2
2 3 1019.64 1 15.34 1683 26 0.22 / 21.69 2 2
3 12 1269.44 5 15.37 1998 154 0.38 / 21.85 2 2
4 7 1608.80 38 15.15 2371 1365 1.74 / 23.21 2 2
5 13 1202.88 18 15.18 1890 516 2.26 / 23.73 2 2
6 13 620.04 18 15.25 1153 316 2.58 / 24.05 2 2
7 13 16.56 18 15.36 356 98 2.67 / 24.14 2 2
8 8 -0.12 165 15.32 330 834 3.51 / 24.98 2 4
9 14 -0.12 75 15.28 324 371 3.88 / 25.35 2 8
Average= 3.17
(KJ/cycle)

Cycle 6 GMT 29/ 7/2021 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 28 15.27 475 203 0.20 / 18.20 2 2
2 3 1020.56 1 15.34 1682 26 0.23 / 18.22 2 2
3 7 1520.08 39 15.19 2232 1322 1.55 / 19.54 2 2
4 13 1400.64 18 15.17 2115 578 2.13 / 20.12 2 2
5 13 949.80 18 15.21 1566 429 2.56 / 20.55 2 2
6 13 95.84 18 15.35 451 125 2.68 / 20.68 2 2
7 8 0.16 165 15.33 314 794 3.48 / 21.47 2 5
Average= 3.07
(KJ/cycle)

Cycle 5 GMT 19/ 7/2021 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 29 15.25 460 203 0.20 / 14.75 2 2
2 3 953.60 -1 15.60 0 0 0.00 / 14.75 2 2
3 7 1515.44 38 15.19 2229 1287 1.49 / 16.03 2 2
4 13 1388.76 18 15.18 2102 574 2.06 / 16.61 2 2
5 13 935.60 18 15.21 1542 422 2.49 / 17.03 2 2
6 13 173.28 18 15.34 566 156 2.64 / 17.18 2 2
7 8 0.20 165 15.32 320 809 3.45 / 17.99 2 4
Average= 3.00
(KJ/cycle)

Cycle 4 GMT 9/ 7/2021 17:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 28 15.28 472 202 0.20 / 11.49 2 2
2 7 1512.20 38 15.16 2227 1283 1.48 / 12.78 2 2
3 13 1129.04 18 15.18 1807 494 1.98 / 13.27 2 2
4 13 728.64 18 15.22 1286 352 2.33 / 13.62 2 2
5 13 66.24 18 15.35 421 116 2.45 / 13.74 2 2
6 8 -0.16 165 15.32 318 804 3.25 / 14.54 2 6
Average= 2.91
(KJ/cycle)

Cycle 3 GMT 8/ 7/2021 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 30 15.27 452 207 0.21 / 8.18 2 2
2 3 909.48 -2 15.59 0 0 0.00 / 8.18 2 2
3 7 1510.88 39 15.15 2216 1309 1.52 / 9.49 2 2
4 13 1381.08 18 15.14 2082 567 2.08 / 10.05 2 2
5 13 651.28 18 15.25 1174 322 2.41 / 10.38 2 2
6 13 105.60 18 15.34 458 126 2.53 / 10.50 2 2
7 8 0.24 165 15.32 312 789 3.32 / 11.29 2 5
Average= 2.82
(KJ/cycle)

Cycle 2 GMT 7/ 7/2021 17: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 32 15.27 450 220 0.22 / 4.58 2 2
2 3 839.36 -3 15.58 0 0 0.00 / 4.58 2 2
3 3 1081.20 2 15.31 1760 54 0.27 / 4.63 2 2
4 7 1505.84 74 15.05 2202 2452 2.73 / 7.08 2 2
5 13 139.96 18 15.33 491 135 2.86 / 7.22 2 2
6 8 -0.20 165 15.32 297 751 3.61 / 7.97 2 4
Average= 2.66
(KJ/cycle)

Cycle 1 GMT 6/ 7/2021 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 15.43 426 177 0.18 / 1.81 2 2
2 3 1024.80 1 15.35 1672 26 0.20 / 1.84 2 2
3 7 991.84 74 15.18 1562 1755 1.96 / 3.59 2 2
4 8 0.08 165 15.32 303 766 2.72 / 4.36 2 6
Average= 2.18
(KJ/cycle)

Cycle 0 GMT 6/ 7/2021 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.08 26 15.57 392 159 0.16 / 0.16 2 2
2 7 86.52 74 15.53 397 456 0.61 / 0.61 2 2
3 8 0.20 240 15.49 274 1019 1.63 / 1.63 2 5
Average= 1.63
(KJ/cycle)