SIO Argo Site:
Pump Diagnostics Page   



Serial= 8925 WMO= 5906424

Return

←PreviousNext→

Cycle 130 GMT 13/12/2024 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 14.91 403 192 0.19 / 501.22 3 3
2 7 2005.88 33 14.83 2960 1449 1.64 / 502.67 2 3
3 13 1612.00 20 14.81 2475 733 2.37 / 503.40 2 5
4 13 1049.20 20 14.83 1739 516 2.89 / 503.92 2 5
5 13 454.24 20 14.91 917 273 3.16 / 504.19 2 3
6 13 40.60 20 14.98 318 95 3.26 / 504.29 2 2
7 8 0.00 165 14.96 253 625 3.88 / 504.91 2 5
Average= 3.85
(KJ/cycle)

Cycle 129 GMT 3/12/2024 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 32 14.92 435 208 0.21 / 497.20 2 3
2 7 2011.04 32 14.82 2979 1413 1.62 / 498.62 2 4
3 13 1595.48 20 14.80 2458 728 2.35 / 499.34 2 5
4 13 1161.68 20 14.81 1891 560 2.91 / 499.90 2 6
5 13 428.36 20 14.92 883 263 3.17 / 500.17 2 3
6 13 73.96 20 14.97 366 110 3.28 / 500.28 2 2
7 8 0.08 165 14.95 259 639 3.92 / 500.92 2 5
8 14 0.08 30 14.94 254 114 4.03 / 501.03 2 7
Average= 3.85
(KJ/cycle)

Cycle 128 GMT 23/11/2024 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 32 14.91 436 208 0.21 / 493.22 2 3
2 10 1001.72 2 15.07 1711 52 0.26 / 493.27 2 5
3 3 944.56 -1 15.34 0 0 0.05 / 493.27 2 5
4 7 2010.52 32 14.83 2975 1412 1.67 / 494.69 2 3
5 13 1616.76 20 14.81 2490 738 2.41 / 495.42 2 3
6 13 1066.56 20 14.84 1766 524 2.93 / 495.95 2 3
7 13 487.88 20 14.91 971 290 3.22 / 496.24 2 3
8 13 49.96 20 14.98 346 104 3.33 / 496.34 2 2
9 8 0.12 165 14.96 265 654 3.98 / 497.00 2 7
Average= 3.85
(KJ/cycle)

Cycle 127 GMT 13/11/2024 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 32 14.93 416 199 0.20 / 489.24 2 3
2 7 2008.24 33 14.81 2990 1461 1.66 / 490.70 2 2
3 13 1600.24 20 14.80 2472 732 2.39 / 491.43 2 3
4 13 1038.24 20 14.83 1728 513 2.90 / 491.95 2 3
5 13 465.72 20 14.91 945 282 3.19 / 492.23 2 3
6 13 83.64 20 14.98 395 118 3.30 / 492.35 2 2
7 8 0.04 165 14.95 271 668 3.97 / 493.02 2 5
Average= 3.85
(KJ/cycle)

Cycle 126 GMT 4/11/2024 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 32 14.93 413 197 0.20 / 485.27 2 3
2 3 1017.00 1 15.12 1730 26 0.22 / 485.29 2 3
3 7 2010.48 32 14.83 2983 1416 1.64 / 486.71 2 3
4 13 1733.44 20 14.78 2652 784 2.42 / 487.49 2 3
5 13 1025.72 20 14.84 1720 510 2.93 / 488.00 2 4
6 13 453.48 20 14.92 927 277 3.21 / 488.28 2 3
7 13 94.92 20 14.98 396 119 3.33 / 488.40 2 3
8 8 0.36 165 14.97 261 645 3.97 / 489.04 2 3
Average= 3.85
(KJ/cycle)

Cycle 125 GMT 25/10/2024 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 31 14.94 438 203 0.20 / 481.20 2 3
2 7 2002.84 32 14.84 2969 1410 1.61 / 482.61 2 3
3 13 1597.72 20 14.82 2472 733 2.35 / 483.34 2 4
4 13 1160.36 20 14.82 1898 563 2.91 / 483.91 2 6
5 13 430.04 20 14.93 889 265 3.17 / 484.17 2 3
6 13 82.72 20 14.99 379 114 3.29 / 484.28 2 2
7 8 -0.16 165 14.98 269 665 3.95 / 484.95 2 5
8 14 -0.16 30 14.95 265 119 4.07 / 485.07 3 5
Average= 3.85
(KJ/cycle)

Cycle 124 GMT 15/10/2024 13:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 31 14.95 415 192 0.19 / 477.23 2 3
2 7 2009.88 33 14.83 2981 1459 1.65 / 478.69 2 3
3 13 1601.08 20 14.82 2481 735 2.39 / 479.43 2 3
4 13 1034.48 20 14.85 1734 515 2.90 / 479.94 2 4
5 13 447.12 20 14.94 927 277 3.18 / 480.22 2 3
6 13 76.12 20 15.00 384 115 3.29 / 480.33 2 2
7 8 0.20 165 14.98 269 665 3.96 / 481.00 2 7
Average= 3.85
(KJ/cycle)

Cycle 123 GMT 5/10/2024 18:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 31 14.93 434 201 0.20 / 473.24 2 2
2 7 2005.44 32 14.82 2974 1410 1.61 / 474.65 2 4
3 13 1613.44 20 14.81 2491 738 2.35 / 475.39 2 3
4 13 1048.72 20 14.84 1753 520 2.87 / 475.91 2 3
5 13 348.32 20 14.96 780 233 3.10 / 476.14 2 3
6 13 99.68 20 15.01 419 126 3.23 / 476.27 2 2
7 8 0.20 165 14.99 264 653 3.88 / 476.92 2 5
8 14 0.20 30 14.97 264 119 4.00 / 477.04 2 6
Average= 3.85
(KJ/cycle)

Cycle 122 GMT 25/ 9/2024 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 31 14.96 436 202 0.20 / 469.30 2 3
2 7 2012.12 32 14.80 2987 1415 1.62 / 470.71 2 3
3 13 1613.84 20 14.80 2489 737 2.35 / 471.45 2 4
4 13 1048.44 20 14.83 1746 518 2.87 / 471.97 2 5
5 13 461.40 20 14.92 952 284 3.16 / 472.25 2 4
6 13 30.60 20 15.00 331 99 3.25 / 472.35 2 2
7 8 0.04 165 14.97 279 689 3.94 / 473.04 2 7
Average= 3.85
(KJ/cycle)

Cycle 121 GMT 16/ 9/2024 4:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 31 14.95 437 203 0.20 / 465.38 2 3
2 7 2003.76 32 14.83 2978 1413 1.62 / 466.79 2 4
3 13 1609.80 20 14.82 2488 737 2.35 / 467.53 2 3
4 13 1038.72 20 14.85 1737 516 2.87 / 468.04 2 4
5 13 454.88 20 14.94 935 279 3.15 / 468.32 2 3
6 13 67.24 20 15.01 375 113 3.26 / 468.43 2 3
7 8 0.00 165 14.99 267 660 3.92 / 469.10 2 6
Average= 3.85
(KJ/cycle)

Cycle 120 GMT 6/ 9/2024 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 31 14.95 443 205 0.21 / 461.50 2 2
2 7 2008.56 32 14.83 2987 1418 1.62 / 462.92 2 4
3 13 1605.20 20 14.81 2487 737 2.36 / 463.66 2 3
4 13 1031.28 20 14.85 1732 514 2.87 / 464.17 2 4
5 13 336.28 20 14.97 769 230 3.10 / 464.40 2 3
6 13 19.96 20 15.04 307 92 3.20 / 464.49 2 2
7 8 0.28 165 15.00 275 681 3.88 / 465.17 2 3
Average= 3.84
(KJ/cycle)

Cycle 119 GMT 27/ 8/2024 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 31 14.96 439 204 0.20 / 457.65 2 3
2 7 2012.20 32 14.84 2984 1417 1.62 / 459.07 2 4
3 13 1617.56 20 14.80 2496 739 2.36 / 459.81 2 3
4 13 1054.08 20 14.85 1754 521 2.88 / 460.33 2 5
5 13 469.16 20 14.93 963 288 3.17 / 460.61 2 3
6 8 0.16 165 14.99 276 683 3.85 / 461.30 2 6
Average= 3.84
(KJ/cycle)

Cycle 118 GMT 17/ 8/2024 16:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 31 14.97 433 201 0.20 / 453.70 2 3
2 7 2002.84 33 14.83 2972 1454 1.66 / 455.15 2 3
3 13 1596.60 20 14.82 2471 732 2.39 / 455.88 2 2
4 13 1026.60 20 14.86 1721 511 2.90 / 456.40 2 6
5 13 429.16 20 14.95 905 271 3.17 / 456.67 2 3
6 13 52.40 20 15.02 357 107 3.28 / 456.77 2 3
7 8 -0.12 165 15.00 272 673 3.95 / 457.45 2 6
Average= 3.84
(KJ/cycle)

Cycle 117 GMT 7/ 8/2024 18:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 14.94 437 209 0.21 / 449.74 2 2
2 7 2010.80 32 14.85 2983 1418 1.63 / 451.16 2 3
3 13 1607.64 20 14.82 2485 737 2.36 / 451.90 2 5
4 13 1036.04 20 14.86 1737 516 2.88 / 452.41 2 3
5 13 461.48 20 14.95 948 283 3.16 / 452.70 2 4
6 8 0.28 165 15.01 274 679 3.84 / 453.37 2 4
7 14 0.28 30 14.99 271 122 3.96 / 453.50 2 5
Average= 3.84
(KJ/cycle)

Cycle 116 GMT 28/ 7/2024 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 31 14.95 448 208 0.21 / 445.68 2 3
2 7 2003.96 32 14.84 2970 1410 1.62 / 447.09 2 3
3 13 1725.12 20 14.81 2641 782 2.40 / 447.87 2 4
4 13 1140.00 20 14.84 1875 556 2.96 / 448.43 2 4
5 13 535.12 20 14.92 1056 315 3.27 / 448.74 2 4
6 13 20.92 20 15.02 318 96 3.37 / 448.84 2 3
7 8 -0.04 165 14.98 280 692 4.06 / 449.53 2 4
Average= 3.84
(KJ/cycle)

Cycle 115 GMT 18/ 7/2024 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 14.94 450 208 0.21 / 441.75 2 3
2 7 2003.56 32 14.84 2960 1406 1.61 / 443.16 2 4
3 13 1585.72 20 14.82 2448 726 2.34 / 443.88 2 3
4 13 1131.00 20 14.85 1859 552 2.89 / 444.44 2 6
5 13 389.80 20 14.96 836 250 3.14 / 444.69 2 3
6 13 59.40 20 15.02 358 108 3.25 / 444.79 2 2
7 8 0.08 165 14.99 275 680 3.93 / 445.47 2 5
Average= 3.84
(KJ/cycle)

Cycle 114 GMT 9/ 7/2024 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 31 14.95 448 208 0.21 / 437.70 2 3
2 7 2005.64 32 14.85 2960 1407 1.61 / 439.10 2 3
3 13 1736.80 20 14.81 2644 783 2.40 / 439.89 2 3
4 13 1133.88 20 14.86 1865 554 2.95 / 440.44 2 4
5 13 541.64 20 14.94 1056 316 3.27 / 440.76 2 3
6 13 49.32 20 15.02 351 105 3.37 / 440.86 2 2
7 8 0.12 165 14.99 275 680 4.05 / 441.54 2 4
Average= 3.84
(KJ/cycle)

Cycle 113 GMT 29/ 6/2024 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 32 14.95 445 213 0.21 / 433.75 2 3
2 7 2008.40 32 14.85 2981 1417 1.63 / 435.17 2 3
3 13 1593.16 20 14.83 2463 731 2.36 / 435.90 2 3
4 13 1023.36 20 14.87 1728 514 2.87 / 436.42 2 5
5 13 440.96 20 14.96 923 276 3.15 / 436.69 2 3
6 13 56.20 20 15.02 371 111 3.26 / 436.80 2 2
7 8 0.16 165 14.99 278 688 3.95 / 437.49 2 6
Average= 3.84
(KJ/cycle)

Cycle 112 GMT 19/ 6/2024 5:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 32 14.95 442 211 0.21 / 429.91 2 2
2 7 2006.24 32 14.83 2975 1412 1.62 / 431.32 2 5
3 13 1607.92 20 14.82 2480 735 2.36 / 432.05 2 4
4 13 1037.20 20 14.86 1740 517 2.88 / 432.57 2 6
5 13 439.36 20 14.94 926 277 3.15 / 432.85 2 3
6 8 0.08 165 15.00 281 695 3.85 / 433.54 2 3
Average= 3.84
(KJ/cycle)

Cycle 111 GMT 9/ 6/2024 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 14.95 413 198 0.20 / 426.14 3 3
2 7 2003.40 32 14.85 2961 1407 1.60 / 427.54 2 3
3 13 1606.60 20 14.83 2469 732 2.34 / 428.28 2 4
4 13 1032.96 20 14.86 1728 514 2.85 / 428.79 2 4
5 13 314.20 20 14.97 741 222 3.07 / 429.01 2 3
6 8 -0.04 165 15.00 276 683 3.76 / 429.69 2 5
Average= 3.84
(KJ/cycle)

Cycle 110 GMT 30/ 5/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 31 14.95 420 195 0.19 / 422.07 2 3
2 3 1018.04 1 15.16 1768 27 0.22 / 422.09 2 3
3 7 2011.16 32 14.84 2968 1409 1.63 / 423.50 2 4
4 13 1617.80 20 14.81 2491 738 2.37 / 424.24 2 5
5 13 1058.88 20 14.85 1755 521 2.89 / 424.76 2 4
6 13 470.76 20 14.94 954 285 3.18 / 425.05 2 4
7 13 85.80 20 15.00 394 118 3.29 / 425.16 2 2
8 8 0.12 165 14.98 264 653 3.95 / 425.82 2 3
9 14 0.12 30 14.96 270 121 4.07 / 425.94 2 4
Average= 3.84
(KJ/cycle)

Cycle 109 GMT 20/ 5/2024 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 14.95 407 189 0.19 / 418.12 2 3
2 7 2002.76 32 14.85 2969 1411 1.60 / 419.53 2 3
3 13 1729.48 20 14.82 2637 782 2.38 / 420.31 2 5
4 13 991.96 20 14.88 1670 497 2.88 / 420.81 2 5
5 13 415.76 20 14.96 880 263 3.14 / 421.07 2 3
6 13 125.76 20 15.01 455 137 3.28 / 421.21 2 2
7 8 0.00 165 14.99 267 660 3.94 / 421.87 2 6
Average= 3.84
(KJ/cycle)

Cycle 108 GMT 10/ 5/2024 15:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 14.94 412 191 0.19 / 414.22 2 3
2 7 2007.16 32 14.85 2975 1414 1.60 / 415.63 2 2
3 13 1594.88 20 14.84 2470 733 2.34 / 416.37 2 4
4 13 1025.56 20 14.87 1727 514 2.85 / 416.88 2 4
5 13 435.32 20 14.96 912 273 3.12 / 417.15 2 3
6 13 74.72 20 15.01 384 115 3.24 / 417.27 2 2
7 8 0.08 165 14.98 269 665 3.90 / 417.93 2 5
Average= 3.83
(KJ/cycle)

Cycle 107 GMT 30/ 4/2024 17:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 14.94 424 196 0.20 / 410.34 2 3
2 7 2004.20 32 14.84 2976 1413 1.61 / 411.75 2 3
3 13 1588.84 20 14.84 2457 729 2.34 / 412.48 2 6
4 13 1023.28 20 14.88 1718 511 2.85 / 412.99 2 6
5 13 430.64 20 14.96 902 270 3.12 / 413.26 2 4
6 13 71.60 20 15.02 381 114 3.23 / 413.38 2 2
7 8 0.12 165 14.98 264 653 3.89 / 414.03 2 6
Average= 3.83
(KJ/cycle)

Cycle 106 GMT 20/ 4/2024 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 32 14.95 412 197 0.20 / 406.28 2 3
2 7 2005.00 32 14.86 2984 1419 1.62 / 407.70 2 3
3 13 1739.00 20 14.82 2650 785 2.40 / 408.48 2 3
4 13 1136.00 20 14.86 1869 555 2.96 / 409.04 2 6
5 13 521.12 20 14.94 1039 310 3.27 / 409.35 2 3
6 13 111.44 20 15.01 434 130 3.40 / 409.48 2 3
7 8 0.04 165 14.98 269 665 4.06 / 410.14 2 7
Average= 3.83
(KJ/cycle)

Cycle 105 GMT 10/ 4/2024 22:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 14.94 415 198 0.20 / 402.38 2 3
2 7 2004.04 32 14.85 2962 1408 1.61 / 403.79 2 2
3 13 1606.68 20 14.84 2471 733 2.34 / 404.52 2 4
4 13 1030.60 20 14.88 1714 510 2.85 / 405.03 2 5
5 13 447.92 20 14.95 919 275 3.12 / 405.31 2 3
6 13 78.04 20 15.02 382 115 3.24 / 405.42 2 2
7 8 0.08 165 14.99 265 655 3.89 / 406.08 2 9
Average= 3.83
(KJ/cycle)

Cycle 104 GMT 1/ 4/2024 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.95 414 198 0.20 / 398.46 2 3
2 7 2003.96 32 14.85 2977 1415 1.61 / 399.88 2 3
3 13 1614.64 20 14.82 2486 737 2.35 / 400.61 2 3
4 13 1054.88 20 14.86 1755 522 2.87 / 401.13 2 6
5 13 460.76 20 14.95 935 280 3.15 / 401.41 2 4
6 13 87.48 20 15.00 393 118 3.27 / 401.53 2 2
7 8 0.12 165 14.98 264 653 3.92 / 402.18 2 3
Average= 3.83
(KJ/cycle)

Cycle 103 GMT 22/ 3/2024 2:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 32 14.96 414 198 0.20 / 394.43 2 3
2 7 2010.20 33 14.84 2993 1466 1.66 / 395.90 2 3
3 13 1607.56 20 14.84 2485 738 2.40 / 396.64 2 5
4 13 1158.48 20 14.85 1899 564 2.97 / 397.20 2 6
5 13 427.64 20 14.96 886 265 3.23 / 397.47 2 3
6 13 146.08 20 14.99 478 143 3.37 / 397.61 2 2
7 8 0.16 165 14.98 265 655 4.03 / 398.26 2 6
Average= 3.83
(KJ/cycle)

Cycle 102 GMT 12/ 3/2024 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.95 410 196 0.20 / 390.50 3 3
2 7 2011.36 32 14.86 2988 1421 1.62 / 391.92 2 3
3 13 1612.80 20 14.84 2489 739 2.36 / 392.66 2 4
4 13 1047.52 20 14.87 1751 521 2.88 / 393.18 2 5
5 13 467.92 20 14.95 949 284 3.16 / 393.46 2 3
6 13 103.16 20 15.01 416 125 3.29 / 393.59 2 2
7 8 0.20 165 14.99 261 646 3.93 / 394.23 2 5
Average= 3.83
(KJ/cycle)

Cycle 101 GMT 2/ 3/2024 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 14.95 420 201 0.20 / 386.58 2 3
2 7 2003.52 32 14.84 2979 1415 1.62 / 388.00 2 3
3 13 1599.60 20 14.83 2478 735 2.35 / 388.73 2 4
4 13 1034.12 20 14.87 1734 516 2.87 / 389.25 2 6
5 13 456.88 20 14.95 932 279 3.14 / 389.52 2 3
6 13 89.04 20 15.00 398 119 3.26 / 389.64 2 2
7 8 0.12 165 14.99 267 660 3.92 / 390.30 2 4
Average= 3.83
(KJ/cycle)

Cycle 100 GMT 21/ 2/2024 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 32 14.94 444 212 0.21 / 382.66 3 3
2 7 2009.80 32 14.85 2978 1415 1.63 / 384.07 2 3
3 13 1604.52 20 14.83 2488 738 2.37 / 384.81 2 4
4 13 1023.92 20 14.88 1715 510 2.88 / 385.32 2 3
5 13 443.60 20 14.96 922 276 3.15 / 385.60 2 3
6 13 81.88 20 15.02 395 119 3.27 / 385.71 2 2
7 8 0.04 165 14.99 269 665 3.94 / 386.38 2 8
Average= 3.83
(KJ/cycle)

Cycle 99 GMT 11/ 2/2024 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 14.97 415 199 0.20 / 378.48 2 3
2 7 2009.80 32 14.86 2980 1417 1.62 / 379.89 2 3
3 13 1601.92 20 14.84 2465 732 2.35 / 380.62 2 5
4 13 1161.24 20 14.86 1907 567 2.91 / 381.19 2 4
5 13 553.64 20 14.95 1082 324 3.24 / 381.51 2 3
6 13 107.20 20 15.01 437 131 3.37 / 381.65 2 2
7 8 0.12 165 15.00 273 676 4.04 / 382.32 2 3
8 14 0.12 30 14.98 272 122 4.17 / 382.44 2 5
Average= 3.82
(KJ/cycle)

Cycle 98 GMT 1/ 2/2024 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 14.97 410 196 0.20 / 374.57 3 3
2 7 2008.12 32 14.85 2972 1412 1.61 / 375.98 2 3
3 13 1597.92 20 14.84 2470 733 2.34 / 376.72 2 4
4 13 1025.36 20 14.88 1722 512 2.85 / 377.23 2 4
5 13 441.96 20 14.97 919 275 3.13 / 377.51 2 3
6 13 63.72 20 15.04 367 110 3.24 / 377.62 2 2
7 8 0.08 165 15.01 267 661 3.90 / 378.28 2 6
Average= 3.82
(KJ/cycle)

Cycle 97 GMT 22/ 1/2024 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 32 14.96 439 210 0.21 / 370.66 2 3
2 7 2009.20 32 14.86 2989 1421 1.63 / 372.08 2 4
3 13 1596.60 20 14.86 2463 732 2.36 / 372.81 2 3
4 13 1020.76 20 14.89 1721 513 2.88 / 373.33 2 6
5 13 432.64 20 14.98 907 272 3.15 / 373.60 2 3
6 13 63.04 20 15.05 373 112 3.26 / 373.71 2 2
7 8 0.12 165 15.01 269 666 3.93 / 374.38 2 4
Average= 3.82
(KJ/cycle)

Cycle 96 GMT 12/ 1/2024 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 14.97 421 202 0.20 / 366.74 3 3
2 7 2009.28 32 14.84 2985 1418 1.62 / 368.16 2 4
3 13 1599.56 20 14.84 2480 736 2.36 / 368.89 2 4
4 13 1013.40 20 14.86 1710 508 2.86 / 369.40 2 5
5 13 423.04 20 14.97 894 268 3.13 / 369.67 2 3
6 13 53.92 20 15.04 360 108 3.24 / 369.78 2 3
7 8 0.00 165 15.01 271 671 3.91 / 370.45 2 4
Average= 3.82
(KJ/cycle)

Cycle 95 GMT 2/ 1/2024 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.98 422 202 0.20 / 362.79 3 3
2 7 2012.24 32 14.85 2991 1421 1.62 / 364.21 2 5
3 13 1611.92 20 14.84 2492 740 2.36 / 364.95 2 4
4 13 1045.72 20 14.88 1752 521 2.88 / 365.47 2 7
5 13 446.68 20 14.97 924 277 3.16 / 365.75 2 3
6 13 81.04 20 15.02 391 117 3.28 / 365.87 2 2
7 8 0.08 165 15.01 271 671 3.95 / 366.54 2 5
Average= 3.82
(KJ/cycle)

Cycle 94 GMT 23/12/2023 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 32 14.98 415 199 0.20 / 358.87 3 3
2 7 2003.44 32 14.86 2988 1421 1.62 / 360.29 2 3
3 13 1590.36 20 14.86 2475 736 2.36 / 361.03 2 4
4 13 1018.72 20 14.88 1721 512 2.87 / 361.54 2 6
5 13 425.96 20 14.97 890 266 3.13 / 361.81 2 3
6 13 75.20 20 15.05 379 114 3.25 / 361.92 2 2
7 8 0.12 165 15.02 269 667 3.91 / 362.59 2 7
Average= 3.82
(KJ/cycle)

Cycle 93 GMT 14/12/2023 1:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.04 32 14.98 442 212 0.21 / 354.94 2 3
2 7 2009.44 32 14.86 2994 1424 1.64 / 356.36 2 3
3 13 1602.96 20 14.84 2480 736 2.37 / 357.10 2 4
4 13 1040.68 20 14.88 1741 518 2.89 / 357.62 2 4
5 13 443.60 20 14.98 921 276 3.17 / 357.89 2 3
6 13 78.08 20 15.04 384 116 3.28 / 358.01 2 2
7 8 0.16 165 15.03 268 665 3.95 / 358.67 2 4
Average= 3.82
(KJ/cycle)

Cycle 92 GMT 4/12/2023 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 14.99 413 192 0.19 / 350.93 3 3
2 3 1018.84 1 15.21 1756 27 0.22 / 350.96 2 4
3 7 2005.80 33 14.87 2985 1465 1.68 / 352.42 2 3
4 13 1603.00 20 14.86 2482 738 2.42 / 353.16 2 5
5 13 1027.68 20 14.90 1724 514 2.93 / 353.68 2 5
6 13 446.80 20 14.98 924 277 3.21 / 353.95 2 3
7 13 76.04 20 15.04 381 115 3.33 / 354.07 2 2
8 8 0.04 165 15.02 267 662 3.99 / 354.73 2 4
Average= 3.81
(KJ/cycle)

Cycle 91 GMT 24/11/2023 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 14.99 440 204 0.20 / 346.98 2 3
2 7 2010.48 33 14.87 2978 1461 1.67 / 348.44 2 3
3 13 1497.32 20 14.87 2338 695 2.36 / 349.13 2 4
4 13 1078.28 20 14.89 1789 533 2.89 / 349.67 2 5
5 13 478.44 20 14.98 968 290 3.18 / 349.96 2 4
6 13 98.48 20 15.05 410 123 3.31 / 350.08 2 2
7 8 0.24 165 15.03 267 662 3.97 / 350.74 2 5
Average= 3.81
(KJ/cycle)

Cycle 90 GMT 14/11/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 31 15.00 437 203 0.20 / 343.00 2 3
2 7 2007.76 32 14.89 2975 1418 1.62 / 344.42 2 6
3 13 1726.60 20 14.85 2625 780 2.40 / 345.20 2 4
4 13 1010.00 20 14.91 1697 506 2.91 / 345.71 2 4
5 13 437.88 20 14.99 917 275 3.18 / 345.98 2 3
6 13 26.36 20 15.08 322 97 3.28 / 346.08 2 2
7 8 -0.08 165 15.04 279 692 3.97 / 346.77 2 5
Average= 3.81
(KJ/cycle)

Cycle 89 GMT 4/11/2023 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 15.01 429 200 0.20 / 339.08 2 3
2 7 2004.20 32 14.89 2968 1414 1.61 / 340.49 2 3
3 13 1602.52 20 14.87 2468 734 2.35 / 341.23 2 3
4 13 1024.28 20 14.92 1720 513 2.86 / 341.74 2 4
5 13 442.80 20 15.00 927 278 3.14 / 342.02 2 3
6 13 59.16 20 15.08 368 111 3.25 / 342.13 2 2
7 8 0.08 165 15.04 271 673 3.92 / 342.80 2 6
Average= 3.81
(KJ/cycle)

Cycle 88 GMT 25/10/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 31 15.01 445 207 0.21 / 335.23 2 3
2 7 2011.00 32 14.88 2978 1418 1.63 / 336.64 2 4
3 13 1486.76 20 14.89 2325 692 2.32 / 337.34 2 4
4 13 1057.64 20 14.91 1763 526 2.84 / 337.86 2 5
5 13 326.72 20 15.03 759 228 3.07 / 338.09 2 3
6 13 41.56 20 15.07 346 104 3.18 / 338.20 2 2
7 8 -0.04 165 15.05 275 683 3.86 / 338.88 2 7
Average= 3.81
(KJ/cycle)

Cycle 87 GMT 15/10/2023 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 31 15.01 442 206 0.21 / 331.28 2 3
2 7 2011.52 32 14.87 2978 1417 1.62 / 332.70 2 4
3 13 1601.08 20 14.87 2473 735 2.36 / 333.44 2 3
4 13 1017.72 20 14.92 1711 511 2.87 / 333.95 2 5
5 13 435.08 20 15.00 911 273 3.14 / 334.22 2 3
6 13 57.28 20 15.08 367 111 3.25 / 334.33 2 2
7 8 0.04 165 15.05 277 688 3.94 / 335.02 2 6
Average= 3.81
(KJ/cycle)

Cycle 86 GMT 5/10/2023 16:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 31 15.00 446 207 0.21 / 327.33 2 3
2 7 2008.68 32 14.88 2980 1419 1.63 / 328.75 2 3
3 13 1600.24 20 14.87 2461 732 2.36 / 329.49 2 5
4 13 1024.56 20 14.91 1720 513 2.87 / 330.00 2 7
5 13 429.88 20 15.00 910 273 3.14 / 330.27 2 3
6 13 55.00 20 15.08 373 112 3.26 / 330.38 2 3
7 8 0.08 165 15.05 280 695 3.95 / 331.08 2 10
Average= 3.81
(KJ/cycle)

Cycle 85 GMT 25/ 9/2023 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 31 15.01 425 198 0.20 / 323.40 2 3
2 7 2009.08 32 14.89 2983 1421 1.62 / 324.82 2 4
3 13 1600.72 20 14.88 2473 736 2.36 / 325.55 2 3
4 13 1021.32 20 14.91 1716 512 2.87 / 326.06 2 4
5 13 437.88 20 15.00 918 275 3.14 / 326.34 2 3
6 13 29.56 20 15.08 328 99 3.24 / 326.44 2 2
7 8 0.08 165 15.05 277 688 3.93 / 327.13 2 6
Average= 3.80
(KJ/cycle)

Cycle 84 GMT 15/ 9/2023 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 31 15.03 449 209 0.21 / 319.60 2 3
2 7 2003.44 32 14.87 2963 1410 1.62 / 321.01 2 2
3 13 1481.12 20 14.88 2315 689 2.31 / 321.70 2 2
4 13 937.12 20 14.92 1602 478 2.79 / 322.18 2 2
5 13 374.28 20 15.01 816 245 3.03 / 322.42 2 2
6 13 24.32 20 15.08 311 94 3.12 / 322.52 2 2
7 8 0.24 165 15.05 274 680 3.81 / 323.20 2 4
Average= 3.80
(KJ/cycle)

Cycle 83 GMT 5/ 9/2023 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 31 15.03 448 209 0.21 / 315.69 2 3
2 7 2009.36 32 14.90 2974 1418 1.63 / 317.11 2 2
3 13 1604.76 20 14.88 2483 739 2.37 / 317.84 2 2
4 13 1037.32 20 14.93 1739 519 2.88 / 318.36 2 2
5 13 336.36 20 15.04 765 230 3.12 / 318.59 2 2
6 13 49.84 20 15.10 355 107 3.22 / 318.70 2 2
7 8 0.04 165 15.07 278 691 3.91 / 319.39 2 4
Average= 3.80
(KJ/cycle)

Cycle 82 GMT 27/ 8/2023 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 31 15.03 449 209 0.21 / 311.82 2 3
2 7 2009.80 32 14.88 2982 1420 1.63 / 313.24 2 2
3 13 1485.68 20 14.90 2325 693 2.32 / 313.94 2 2
4 13 1064.16 20 14.91 1775 529 2.85 / 314.46 2 2
5 13 337.24 20 15.04 772 232 3.08 / 314.70 2 2
6 13 45.28 20 15.09 350 106 3.19 / 314.80 2 2
7 8 0.12 165 15.07 272 676 3.87 / 315.48 2 3
Average= 3.80
(KJ/cycle)

Cycle 81 GMT 17/ 8/2023 3:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 31 15.06 427 199 0.20 / 307.88 2 3
2 7 2010.36 32 14.90 2981 1421 1.62 / 309.30 2 2
3 13 1597.00 20 14.88 2465 734 2.35 / 310.04 2 2
4 13 1028.92 20 14.93 1726 515 2.87 / 310.55 2 2
5 13 437.56 20 15.03 913 274 3.14 / 310.83 2 2
6 13 60.88 20 15.10 369 111 3.26 / 310.94 2 2
7 8 0.04 165 15.08 272 677 3.93 / 311.61 2 5
Average= 3.80
(KJ/cycle)

Cycle 80 GMT 7/ 8/2023 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 31 15.04 448 209 0.21 / 303.99 2 3
2 7 2010.24 32 14.90 2972 1417 1.63 / 305.41 2 2
3 13 1603.44 20 14.89 2482 739 2.37 / 306.15 2 2
4 13 1034.28 20 14.94 1740 520 2.88 / 306.67 2 2
5 13 333.36 20 15.07 767 231 3.12 / 306.90 2 2
6 13 42.72 20 15.11 341 103 3.22 / 307.00 2 2
7 8 0.00 165 15.08 273 679 3.90 / 307.68 2 3
Average= 3.80
(KJ/cycle)

Cycle 79 GMT 28/ 7/2023 7:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 31 15.06 423 197 0.20 / 300.05 2 3
2 7 2002.96 32 14.90 2966 1414 1.61 / 301.46 2 2
3 13 1600.40 20 14.89 2477 738 2.35 / 302.20 2 2
4 13 1026.64 20 14.93 1721 514 2.86 / 302.72 2 2
5 13 441.80 20 15.05 923 278 3.14 / 302.99 2 2
6 13 65.36 20 15.11 371 112 3.25 / 303.11 2 2
7 8 0.12 165 15.09 272 677 3.93 / 303.78 2 4
Average= 3.80
(KJ/cycle)

Cycle 78 GMT 18/ 7/2023 10:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 31 15.05 420 196 0.20 / 296.09 2 3
2 7 2012.64 32 14.89 2992 1426 1.62 / 297.51 2 2
3 13 1600.04 20 14.89 2482 739 2.36 / 298.25 2 2
4 13 1032.84 20 14.93 1730 517 2.88 / 298.77 2 2
5 13 446.52 20 15.03 929 279 3.16 / 299.05 2 2
6 13 69.56 20 15.11 382 115 3.27 / 299.17 2 2
7 8 0.04 165 15.09 276 687 3.96 / 299.85 2 3
Average= 3.80
(KJ/cycle)

Cycle 77 GMT 8/ 7/2023 12:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 31 15.04 430 200 0.20 / 292.13 2 3
2 7 2006.24 32 14.91 2988 1426 1.63 / 293.56 2 2
3 13 1605.32 20 14.89 2484 740 2.37 / 294.30 2 2
4 13 1028.16 20 14.93 1725 515 2.88 / 294.81 2 2
5 13 446.20 20 15.03 929 279 3.16 / 295.09 2 2
6 13 67.88 20 15.11 381 115 3.28 / 295.21 2 2
7 8 0.04 165 15.09 275 685 3.96 / 295.89 2 8
Average= 3.79
(KJ/cycle)

Cycle 76 GMT 28/ 6/2023 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 15.07 417 195 0.19 / 288.20 2 3
2 7 2004.64 32 14.90 2981 1421 1.62 / 289.62 2 2
3 13 1586.00 20 14.88 2448 729 2.34 / 290.35 2 2
4 13 1010.96 20 14.93 1706 509 2.85 / 290.86 2 2
5 13 427.52 20 15.04 899 270 3.12 / 291.13 2 2
6 13 63.48 20 15.12 371 112 3.24 / 291.24 2 2
7 8 0.12 165 15.09 278 692 3.93 / 291.93 2 9
Average= 3.79
(KJ/cycle)

Cycle 75 GMT 18/ 6/2023 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 31 15.06 453 211 0.21 / 284.23 2 3
2 7 2003.16 33 14.90 2983 1467 1.68 / 285.69 2 2
3 13 1598.08 20 14.89 2477 738 2.42 / 286.43 2 2
4 13 1022.56 20 14.94 1723 515 2.93 / 286.95 2 2
5 13 425.48 20 15.05 897 270 3.20 / 287.22 2 2
6 13 65.20 20 15.11 372 112 3.31 / 287.33 2 2
7 8 0.12 165 15.10 271 675 3.99 / 288.00 2 4
Average= 3.79
(KJ/cycle)

Cycle 74 GMT 8/ 6/2023 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 31 15.07 421 197 0.20 / 280.22 2 3
2 7 2006.92 32 14.92 2987 1426 1.62 / 281.65 2 2
3 13 1608.96 20 14.90 2494 743 2.37 / 282.39 2 2
4 13 1153.12 20 14.91 1897 566 2.93 / 282.96 2 2
5 13 405.16 20 15.06 873 263 3.19 / 283.22 2 2
6 13 60.28 20 15.12 369 112 3.31 / 283.33 2 2
7 8 0.12 165 15.10 274 683 3.99 / 284.02 2 6
Average= 3.79
(KJ/cycle)

Cycle 73 GMT 29/ 5/2023 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.07 421 197 0.20 / 276.28 2 3
2 7 2012.04 32 14.90 2988 1425 1.62 / 277.71 2 2
3 13 1606.64 20 14.89 2478 738 2.36 / 278.45 2 2
4 13 1026.80 20 14.95 1722 515 2.87 / 278.96 2 2
5 13 429.80 20 15.06 906 273 3.15 / 279.23 2 2
6 13 64.76 20 15.13 374 113 3.26 / 279.35 2 2
7 8 0.12 165 15.12 273 681 3.94 / 280.03 2 5
Average= 3.78
(KJ/cycle)

Cycle 72 GMT 19/ 5/2023 23:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.08 422 197 0.20 / 272.34 2 3
2 7 2009.20 32 14.92 2990 1428 1.62 / 273.77 2 2
3 13 1594.68 20 14.90 2476 738 2.36 / 274.51 2 2
4 13 1018.96 20 14.95 1720 514 2.88 / 275.02 2 2
5 13 439.64 20 15.05 916 276 3.15 / 275.30 2 2
6 13 75.00 20 15.12 389 118 3.27 / 275.41 2 2
7 8 0.00 165 15.10 270 673 3.94 / 276.09 2 4
Average= 3.78
(KJ/cycle)

Cycle 71 GMT 10/ 5/2023 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 31 15.09 447 209 0.21 / 268.44 2 3
2 7 2006.92 32 14.91 2994 1428 1.64 / 269.87 2 2
3 13 1591.84 20 14.91 2473 737 2.38 / 270.61 2 2
4 13 1008.56 20 14.96 1702 509 2.88 / 271.12 2 2
5 13 304.68 20 15.10 724 219 3.10 / 271.34 2 2
6 13 79.20 20 15.14 396 120 3.22 / 271.46 2 2
7 8 0.24 165 15.12 275 686 3.91 / 272.14 2 5
Average= 3.78
(KJ/cycle)

Cycle 70 GMT 30/ 4/2023 4:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 15.10 418 196 0.20 / 264.59 2 3
2 7 2004.40 32 14.92 2978 1422 1.62 / 266.01 2 2
3 13 1464.84 20 14.92 2305 688 2.31 / 266.70 2 2
4 13 1047.20 20 14.95 1755 525 2.83 / 267.22 2 2
5 13 318.20 20 15.11 744 225 3.05 / 267.45 2 2
6 13 44.08 20 15.15 345 105 3.16 / 267.55 2 2
7 8 0.04 165 15.13 274 684 3.84 / 268.23 2 5
Average= 3.78
(KJ/cycle)

Cycle 69 GMT 20/ 4/2023 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 31 15.09 413 193 0.19 / 260.58 2 2
2 7 2008.44 33 14.90 2995 1473 1.67 / 262.06 2 2
3 13 1599.64 20 14.89 2480 739 2.40 / 262.80 2 2
4 13 1024.48 20 14.96 1726 516 2.92 / 263.31 2 2
5 13 432.12 20 15.07 917 276 3.20 / 263.59 2 2
6 13 66.16 20 15.15 382 116 3.31 / 263.70 2 2
7 8 0.04 165 15.13 275 687 4.00 / 264.39 2 4
Average= 3.78
(KJ/cycle)

Cycle 68 GMT 10/ 4/2023 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 15.10 418 196 0.20 / 256.64 3 3
2 7 2004.36 32 14.92 2969 1418 1.61 / 258.06 2 2
3 13 1583.16 20 14.91 2462 734 2.35 / 258.80 2 2
4 13 1012.60 20 14.97 1718 514 2.86 / 259.31 2 2
5 13 429.32 20 15.08 911 275 3.14 / 259.58 2 2
6 13 65.24 20 15.15 379 115 3.25 / 259.70 2 2
7 8 0.12 165 15.13 277 692 3.94 / 260.39 2 5
Average= 3.77
(KJ/cycle)

Cycle 67 GMT 31/ 3/2023 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 31 15.08 420 196 0.20 / 252.76 3 3
2 7 2010.80 32 14.92 2997 1431 1.63 / 254.20 2 2
3 13 1601.96 20 14.92 2487 742 2.37 / 254.94 2 2
4 13 913.32 20 14.99 1584 475 2.84 / 255.41 2 2
5 13 350.64 20 15.10 796 240 3.08 / 255.65 2 2
6 13 50.76 20 15.16 365 111 3.20 / 255.76 2 2
7 8 0.04 165 15.14 274 684 3.88 / 256.45 2 5
Average= 3.77
(KJ/cycle)

Cycle 66 GMT 21/ 3/2023 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 31 15.10 418 196 0.20 / 248.65 2 3
2 3 1013.28 1 15.27 1782 27 0.22 / 248.67 2 2
3 7 2007.00 32 14.90 3001 1431 1.65 / 250.10 2 2
4 13 1598.88 20 14.90 2484 740 2.39 / 250.84 2 2
5 13 1024.56 20 14.96 1729 517 2.91 / 251.36 2 2
6 13 428.72 20 15.08 905 273 3.18 / 251.63 2 2
7 13 62.88 20 15.16 380 115 3.30 / 251.75 2 3
8 8 0.16 165 15.13 278 694 3.99 / 252.44 2 7
9 14 0.16 30 15.11 274 124 4.12 / 252.57 3 4
Average= 3.77
(KJ/cycle)

Cycle 65 GMT 11/ 3/2023 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.10 420 197 0.20 / 244.70 2 3
2 7 2006.32 32 14.93 2984 1426 1.62 / 246.13 2 2
3 13 1588.80 20 14.92 2472 738 2.36 / 246.86 2 2
4 13 1009.00 20 14.97 1707 511 2.87 / 247.38 2 2
5 13 429.80 20 15.08 915 276 3.15 / 247.65 2 2
6 13 64.16 20 15.16 378 115 3.26 / 247.77 2 2
7 8 0.16 165 15.14 274 684 3.95 / 248.45 2 5
Average= 3.76
(KJ/cycle)

Cycle 64 GMT 1/ 3/2023 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 31 15.10 436 204 0.20 / 240.76 2 3
2 7 2003.00 32 14.92 2976 1421 1.62 / 242.18 2 2
3 13 1599.44 20 14.91 2471 737 2.36 / 242.92 2 2
4 13 1004.16 20 14.97 1711 512 2.87 / 243.43 2 2
5 13 408.76 20 15.09 884 267 3.14 / 243.69 2 2
6 13 55.92 20 15.17 373 113 3.25 / 243.81 2 2
7 8 -0.12 165 15.14 279 697 3.95 / 244.50 2 6
Average= 3.76
(KJ/cycle)

Cycle 63 GMT 19/ 2/2023 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 31 15.11 434 203 0.20 / 236.68 3 3
2 7 2008.44 32 14.92 2987 1426 1.63 / 238.11 2 2
3 13 1599.20 20 14.90 2477 738 2.37 / 238.85 2 2
4 13 1010.48 20 14.98 1708 512 2.88 / 239.36 2 2
5 13 420.16 20 15.09 899 271 3.15 / 239.63 2 2
6 13 53.84 20 15.16 366 111 3.26 / 239.74 2 2
7 8 0.28 165 15.13 276 689 3.95 / 240.43 2 5
8 14 0.28 30 15.12 274 124 4.07 / 240.55 2 8
Average= 3.76
(KJ/cycle)

Cycle 62 GMT 9/ 2/2023 21:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 31 15.11 440 206 0.21 / 232.71 2 3
2 7 2009.68 32 14.92 2998 1431 1.64 / 234.14 2 2
3 13 1602.32 20 14.91 2480 740 2.38 / 234.88 2 2
4 13 1018.88 20 14.98 1720 515 2.89 / 235.40 2 2
5 13 425.28 20 15.10 905 273 3.17 / 235.67 2 2
6 13 66.28 20 15.17 383 116 3.28 / 235.79 2 2
7 8 0.04 165 15.14 276 689 3.97 / 236.48 2 4
Average= 3.75
(KJ/cycle)

Cycle 61 GMT 31/ 1/2023 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 15.14 428 201 0.20 / 228.75 2 3
2 7 2007.76 32 14.91 2987 1425 1.63 / 230.17 2 2
3 13 1590.80 20 14.91 2466 735 2.36 / 230.91 2 2
4 13 997.40 20 14.98 1692 507 2.87 / 231.42 2 2
5 13 404.84 20 15.10 877 265 3.13 / 231.68 2 2
6 13 69.08 20 15.18 392 119 3.25 / 231.80 2 2
7 8 0.08 165 15.15 283 707 3.96 / 232.51 2 6
Average= 3.75
(KJ/cycle)

Cycle 60 GMT 21/ 1/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 15.11 433 203 0.20 / 225.41 2 3
2 7 1351.16 32 15.13 2145 1039 1.24 / 226.45 2 2
3 13 1281.04 20 15.09 2061 622 1.86 / 227.07 2 2
4 13 880.88 20 15.10 1534 463 2.33 / 227.53 2 2
5 13 289.56 20 15.19 705 214 2.54 / 227.75 2 2
6 13 63.88 20 15.22 378 115 2.66 / 227.86 2 2
7 8 0.04 165 15.19 273 684 3.34 / 228.55 2 5
Average= 3.75
(KJ/cycle)

Cycle 59 GMT 11/ 1/2023 2:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 15.11 454 206 0.21 / 221.41 3 3
2 7 2003.04 33 14.92 2978 1466 1.67 / 222.88 2 2
3 13 1592.32 20 14.92 2475 739 2.41 / 223.62 2 2
4 13 1004.44 20 14.98 1701 510 2.92 / 224.13 2 2
5 13 401.80 20 15.11 876 265 3.18 / 224.39 2 2
6 13 67.36 20 15.18 385 117 3.30 / 224.51 2 2
7 8 0.12 165 15.15 280 700 4.00 / 225.21 2 6
Average= 3.75
(KJ/cycle)

Cycle 58 GMT 1/ 1/2023 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 30 15.12 449 204 0.20 / 217.46 2 3
2 7 2006.92 32 14.93 2976 1422 1.63 / 218.88 2 2
3 13 1591.96 20 14.92 2470 737 2.36 / 219.62 2 2
4 13 1003.68 20 14.99 1699 509 2.87 / 220.13 2 2
5 13 408.00 20 15.11 882 267 3.14 / 220.39 2 2
6 13 53.40 20 15.18 368 112 3.25 / 220.51 2 2
7 8 0.04 165 15.15 280 700 3.95 / 221.21 2 5
Average= 3.75
(KJ/cycle)

Cycle 57 GMT 22/12/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 15.13 444 202 0.20 / 213.45 2 3
2 7 2003.80 33 14.93 2987 1472 1.67 / 214.92 2 2
3 13 1592.64 20 14.92 2468 736 2.41 / 215.66 2 2
4 13 1004.64 20 14.99 1704 511 2.92 / 216.17 2 2
5 13 402.60 20 15.12 880 266 3.19 / 216.43 2 2
6 13 49.60 20 15.19 365 111 3.30 / 216.54 2 2
7 8 0.16 165 15.16 285 713 4.01 / 217.26 2 5
Average= 3.75
(KJ/cycle)

Cycle 56 GMT 12/12/2022 9:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 30 15.13 461 209 0.21 / 209.54 2 3
2 7 2006.28 32 14.94 2972 1421 1.63 / 210.96 2 2
3 13 1600.12 20 14.93 2483 741 2.37 / 211.71 2 2
4 13 1017.36 20 14.99 1720 516 2.89 / 212.22 2 2
5 13 304.08 20 15.15 732 222 3.11 / 212.44 2 2
6 13 32.64 20 15.20 341 104 3.21 / 212.55 2 2
7 8 0.12 165 15.17 279 698 3.91 / 213.25 2 6
Average= 3.74
(KJ/cycle)

Cycle 55 GMT 2/12/2022 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 15.13 436 198 0.20 / 205.53 2 3
2 7 2004.84 32 14.94 2992 1430 1.63 / 206.96 2 2
3 13 1601.80 20 14.94 2485 743 2.37 / 207.71 2 2
4 13 1026.76 20 14.99 1730 519 2.89 / 208.22 2 2
5 13 431.32 20 15.12 922 279 3.17 / 208.50 2 2
6 13 50.52 20 15.20 370 112 3.28 / 208.62 2 2
7 8 -0.04 165 15.18 287 719 4.00 / 209.33 2 8
Average= 3.74
(KJ/cycle)

Cycle 54 GMT 22/11/2022 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 30 15.14 464 211 0.21 / 201.55 2 3
2 7 2005.24 32 14.94 2979 1424 1.63 / 202.97 2 2
3 13 1581.76 20 14.94 2462 736 2.37 / 203.71 2 2
4 13 999.52 20 15.00 1700 510 2.88 / 204.22 2 2
5 13 409.16 20 15.13 891 270 3.15 / 204.49 2 2
6 13 54.72 20 15.20 382 116 3.27 / 204.61 2 2
7 8 0.08 165 15.18 291 729 4.00 / 205.33 2 8
Average= 3.73
(KJ/cycle)

Cycle 53 GMT 12/11/2022 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 30 15.15 461 210 0.21 / 197.57 2 3
2 7 2011.32 32 14.94 2987 1428 1.64 / 199.00 2 2
3 13 1594.32 20 14.93 2472 738 2.38 / 199.73 2 2
4 13 1004.68 20 15.00 1707 512 2.89 / 200.25 2 2
5 13 404.28 20 15.13 884 267 3.16 / 200.51 2 2
6 13 26.44 20 15.21 333 101 3.26 / 200.62 2 2
7 8 0.08 165 15.18 289 724 3.98 / 201.34 2 6
Average= 3.73
(KJ/cycle)

Cycle 52 GMT 2/11/2022 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 15.15 453 206 0.21 / 193.55 2 3
2 7 2004.32 32 14.95 2971 1421 1.63 / 194.97 2 2
3 13 1731.20 20 14.92 2656 793 2.42 / 195.76 2 2
4 13 993.32 20 15.02 1687 507 2.93 / 196.27 2 2
5 13 397.76 20 15.15 870 264 3.19 / 196.53 2 2
6 13 28.36 20 15.22 339 103 3.29 / 196.64 2 2
7 8 0.04 165 15.18 288 721 4.01 / 197.36 2 5
Average= 3.72
(KJ/cycle)

Cycle 51 GMT 23/10/2022 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 30 15.15 450 205 0.20 / 189.67 2 3
2 7 2004.64 32 14.94 2981 1425 1.63 / 191.09 2 2
3 13 1461.56 20 14.96 2305 690 2.32 / 191.78 2 2
4 13 1029.44 20 14.99 1740 522 2.84 / 192.30 2 2
5 13 290.44 20 15.17 716 217 3.06 / 192.52 2 2
6 13 28.64 20 15.22 334 102 3.16 / 192.62 2 2
7 8 0.12 165 15.18 288 721 3.88 / 193.34 2 5
Average= 3.72
(KJ/cycle)

Cycle 50 GMT 13/10/2022 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 15.16 448 204 0.20 / 185.69 2 3
2 7 2005.96 32 14.96 2977 1425 1.63 / 187.11 2 2
3 13 1596.76 20 14.95 2481 742 2.37 / 187.85 2 2
4 13 1008.12 20 15.02 1700 511 2.88 / 188.37 2 2
5 13 430.20 20 15.15 918 278 3.16 / 188.64 2 2
6 13 26.48 20 15.23 329 100 3.26 / 188.74 2 2
7 8 -0.04 165 15.19 287 719 3.98 / 189.46 2 5
Average= 3.71
(KJ/cycle)

Cycle 49 GMT 4/10/2022 1:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 15.15 459 209 0.21 / 181.78 2 3
2 7 2003.80 32 14.95 2987 1429 1.64 / 183.21 2 2
3 13 1594.00 20 14.94 2474 739 2.38 / 183.95 2 2
4 13 1001.76 20 15.02 1694 509 2.89 / 184.46 2 2
5 13 293.28 20 15.17 719 218 3.10 / 184.68 2 2
6 13 28.08 20 15.22 330 100 3.20 / 184.78 2 2
7 8 0.08 165 15.20 281 705 3.91 / 185.48 2 4
Average= 3.71
(KJ/cycle)

Cycle 48 GMT 24/ 9/2022 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 30 15.18 449 204 0.20 / 177.83 2 3
2 7 2006.96 32 14.96 2996 1434 1.64 / 179.26 2 2
3 13 1594.00 20 14.94 2472 739 2.38 / 180.00 2 2
4 13 1015.40 20 15.02 1720 517 2.89 / 180.52 2 2
5 13 309.40 20 15.17 742 225 3.12 / 180.74 2 2
6 13 34.60 20 15.22 340 103 3.22 / 180.85 2 2
7 8 0.00 165 15.19 290 727 3.95 / 181.58 2 5
Average= 3.71
(KJ/cycle)

Cycle 47 GMT 14/ 9/2022 5:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 30 15.18 423 193 0.19 / 174.07 2 3
2 7 2005.00 32 14.95 2991 1431 1.62 / 175.50 2 2
3 13 1579.88 20 14.94 2458 734 2.36 / 176.24 2 2
4 13 886.36 20 15.07 1546 466 2.82 / 176.70 2 2
5 13 319.36 20 15.18 753 229 3.05 / 176.93 2 2
6 8 0.20 165 15.21 276 693 3.75 / 177.63 2 5
Average= 3.70
(KJ/cycle)

Cycle 46 GMT 4/ 9/2022 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 30 15.16 453 206 0.21 / 170.21 2 3
2 7 2009.40 32 14.95 2990 1430 1.64 / 171.64 2 2
3 13 1595.60 20 14.95 2481 742 2.38 / 172.38 2 2
4 13 989.52 20 15.03 1682 506 2.88 / 172.88 2 2
5 13 279.76 20 15.19 689 209 3.09 / 173.09 2 2
6 13 28.88 20 15.23 321 98 3.19 / 173.19 2 2
7 8 0.00 165 15.21 275 690 3.88 / 173.88 2 5
Average= 3.70
(KJ/cycle)

Cycle 45 GMT 25/ 8/2022 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 15.20 451 206 0.21 / 166.25 2 2
2 7 2003.36 32 14.95 2987 1429 1.63 / 167.68 2 2
3 13 1581.40 20 14.96 2468 738 2.37 / 168.42 2 2
4 13 993.84 20 15.04 1692 509 2.88 / 168.93 2 2
5 13 394.76 20 15.16 869 263 3.15 / 169.19 2 2
6 13 23.48 20 15.24 326 99 3.24 / 169.29 2 2
7 8 0.08 165 15.21 282 708 3.95 / 170.00 2 7
Average= 3.70
(KJ/cycle)

Cycle 44 GMT 15/ 8/2022 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 15.20 458 209 0.21 / 162.94 2 3
2 7 1431.52 32 15.12 2259 1093 1.30 / 164.04 2 2
3 13 1328.44 20 15.10 2138 646 1.95 / 164.68 2 2
4 13 912.20 20 15.11 1583 478 2.43 / 165.16 2 2
5 13 181.76 20 15.25 556 170 2.60 / 165.33 2 2
6 8 0.08 165 15.24 285 717 3.31 / 166.05 2 4
Average= 3.69
(KJ/cycle)

Cycle 43 GMT 5/ 8/2022 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 30 15.16 456 207 0.21 / 159.31 2 2
2 7 1655.04 33 15.07 2530 1258 1.47 / 160.57 2 2
3 13 1531.44 20 15.02 2401 721 2.19 / 161.29 2 2
4 13 925.92 20 15.09 1600 483 2.67 / 161.77 2 2
5 13 326.04 20 15.21 768 234 2.90 / 162.01 2 2
6 8 0.12 165 15.24 289 727 3.63 / 162.73 2 3
Average= 3.70
(KJ/cycle)

Cycle 42 GMT 26/ 7/2022 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 30 15.18 456 208 0.21 / 155.31 2 3
2 7 2009.52 32 14.97 2999 1437 1.64 / 156.75 2 2
3 13 1586.56 20 14.97 2474 741 2.39 / 157.49 2 2
4 13 1003.52 20 15.04 1707 513 2.90 / 158.00 2 2
5 13 420.64 20 15.16 911 276 3.17 / 158.28 2 2
6 13 26.00 20 15.24 331 101 3.28 / 158.38 2 2
7 8 0.04 165 15.21 288 723 4.00 / 159.10 2 5
Average= 3.70
(KJ/cycle)

Cycle 41 GMT 16/ 7/2022 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 15.17 449 204 0.20 / 151.32 2 2
2 7 2003.96 32 14.96 2987 1430 1.63 / 152.75 2 2
3 13 1583.24 20 14.96 2451 733 2.37 / 153.48 2 2
4 13 1006.12 20 15.04 1707 513 2.88 / 154.00 2 2
5 13 422.56 20 15.15 906 275 3.16 / 154.27 2 2
6 13 59.28 20 15.24 379 116 3.27 / 154.39 2 2
7 8 0.16 165 15.21 287 720 3.99 / 155.11 2 8
Average= 3.69
(KJ/cycle)

Cycle 40 GMT 6/ 7/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 30 15.18 463 211 0.21 / 147.43 2 2
2 7 2008.56 32 14.96 2986 1429 1.64 / 148.86 2 2
3 13 1468.56 20 14.98 2322 696 2.34 / 149.55 2 2
4 13 1038.68 20 15.03 1758 528 2.86 / 150.08 2 2
5 13 307.12 20 15.19 743 226 3.09 / 150.31 2 2
6 13 32.84 20 15.24 338 103 3.19 / 150.41 2 2
7 8 -0.12 165 15.21 280 703 3.90 / 151.11 2 4
Average= 3.69
(KJ/cycle)

Cycle 39 GMT 26/ 6/2022 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.18 456 208 0.21 / 143.44 2 3
2 7 2003.16 32 14.96 2992 1432 1.64 / 144.87 2 2
3 13 1580.68 20 14.96 2470 739 2.38 / 145.61 2 2
4 13 993.60 20 15.05 1694 510 2.89 / 146.12 2 2
5 13 394.84 20 15.17 868 263 3.15 / 146.38 2 2
6 13 51.24 20 15.24 370 113 3.27 / 146.49 2 2
7 8 0.00 165 15.22 289 726 3.99 / 147.22 2 9
Average= 3.68
(KJ/cycle)

Cycle 38 GMT 16/ 6/2022 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 30 15.18 450 205 0.20 / 139.40 2 3
2 7 2006.56 32 14.97 2991 1433 1.64 / 140.83 2 2
3 13 1614.56 20 14.95 2501 748 2.39 / 141.58 2 2
4 13 1047.32 20 15.04 1761 530 2.92 / 142.11 2 2
5 13 451.48 20 15.17 949 288 3.20 / 142.40 2 2
6 13 63.48 20 15.24 385 117 3.32 / 142.51 2 2
7 8 0.12 165 15.22 285 716 4.04 / 143.23 2 6
Average= 3.67
(KJ/cycle)

Cycle 37 GMT 6/ 6/2022 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.18 448 204 0.20 / 135.44 3 3
2 7 2008.04 32 14.97 2991 1433 1.64 / 136.87 2 2
3 13 1621.04 20 14.97 2508 751 2.39 / 137.62 2 2
4 13 1054.52 20 15.04 1774 534 2.92 / 138.16 2 2
5 13 341.80 20 15.19 783 238 3.16 / 138.39 2 2
6 13 44.04 20 15.25 348 106 3.27 / 138.50 2 2
7 8 0.20 165 15.23 275 691 3.96 / 139.19 2 5
Average= 3.66
(KJ/cycle)

Cycle 36 GMT 28/ 5/2022 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.18 432 197 0.20 / 131.42 2 3
2 7 2004.24 33 14.96 2998 1480 1.68 / 132.90 2 2
3 13 1586.64 20 14.96 2477 741 2.42 / 133.64 2 2
4 13 998.80 20 15.05 1700 512 2.93 / 134.15 2 2
5 13 410.80 20 15.17 891 270 3.20 / 134.42 2 2
6 13 53.12 20 15.24 367 112 3.31 / 134.53 2 2
7 8 -0.04 165 15.22 280 703 4.01 / 135.24 2 5
Average= 3.66
(KJ/cycle)

Cycle 35 GMT 18/ 5/2022 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 15.19 426 194 0.19 / 127.34 2 3
2 3 1016.20 1 15.30 1800 28 0.22 / 127.36 2 2
3 7 2005.04 32 14.97 3012 1443 1.66 / 128.81 2 2
4 13 1613.84 20 14.96 2513 752 2.42 / 129.56 2 2
5 13 1039.72 20 15.04 1756 528 2.94 / 130.09 2 2
6 13 444.88 20 15.16 941 285 3.23 / 130.37 2 2
7 13 64.88 20 15.24 390 119 3.35 / 130.49 2 2
8 8 0.00 165 15.21 291 730 4.08 / 131.22 2 4
Average= 3.65
(KJ/cycle)

Cycle 34 GMT 8/ 5/2022 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.20 439 200 0.20 / 123.35 2 3
2 7 2003.44 32 14.99 2997 1438 1.64 / 124.79 2 2
3 13 1585.72 20 14.98 2469 740 2.38 / 125.53 2 2
4 13 1002.64 20 15.05 1704 513 2.89 / 126.04 2 2
5 13 414.08 20 15.18 892 271 3.16 / 126.31 2 2
6 13 64.04 20 15.25 384 117 3.28 / 126.43 2 2
7 8 0.12 165 15.23 283 711 3.99 / 127.14 2 7
Average= 3.63
(KJ/cycle)

Cycle 33 GMT 28/ 4/2022 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 15.19 425 194 0.19 / 119.36 2 3
2 7 2003.44 32 14.98 2996 1436 1.63 / 120.80 2 2
3 13 1584.96 20 14.98 2485 745 2.37 / 121.54 2 2
4 13 1002.60 20 15.06 1707 514 2.89 / 122.06 2 2
5 13 405.04 20 15.19 882 268 3.16 / 122.33 2 2
6 13 55.52 20 15.26 369 113 3.27 / 122.44 2 2
7 8 -0.08 165 15.22 284 713 3.98 / 123.15 2 4
Average= 3.62
(KJ/cycle)

Cycle 32 GMT 18/ 4/2022 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 15.19 427 195 0.19 / 115.38 2 3
2 7 2003.56 32 15.00 2990 1435 1.63 / 116.82 2 2
3 13 1600.52 20 14.99 2488 746 2.38 / 117.56 2 2
4 13 1016.72 20 15.07 1719 518 2.89 / 118.08 2 2
5 13 432.72 20 15.20 914 278 3.17 / 118.36 2 2
6 13 56.68 20 15.26 372 114 3.29 / 118.47 2 2
7 8 0.16 165 15.24 277 697 3.98 / 119.17 2 4
Average= 3.61
(KJ/cycle)

Cycle 31 GMT 8/ 4/2022 11:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 15.20 423 193 0.19 / 111.41 2 3
2 7 2003.76 32 14.99 2978 1428 1.62 / 112.84 2 2
3 13 1582.28 20 14.98 2470 740 2.36 / 113.58 2 2
4 13 1013.52 20 15.06 1721 518 2.88 / 114.09 2 2
5 13 409.28 20 15.19 890 270 3.15 / 114.36 2 2
6 13 45.16 20 15.26 360 110 3.26 / 114.47 2 2
7 8 0.12 165 15.24 284 714 3.97 / 115.19 2 4
Average= 3.60
(KJ/cycle)

Cycle 30 GMT 29/ 3/2022 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 15.20 433 197 0.20 / 107.49 2 3
2 7 2002.96 32 14.98 2985 1431 1.63 / 108.92 2 2
3 13 1584.84 20 14.98 2478 742 2.37 / 109.66 2 2
4 13 994.60 20 15.07 1691 510 2.88 / 110.17 2 2
5 13 275.52 20 15.23 700 213 3.09 / 110.39 2 2
6 13 31.44 20 15.27 342 104 3.20 / 110.49 2 2
7 8 0.00 165 15.24 287 722 3.92 / 111.21 2 10
Average= 3.59
(KJ/cycle)

Cycle 29 GMT 19/ 3/2022 15:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 30 15.19 441 201 0.20 / 103.47 2 3
2 7 2002.12 32 15.00 2986 1433 1.63 / 104.90 2 2
3 13 1594.28 20 14.99 2476 742 2.38 / 105.64 2 2
4 13 1032.32 20 15.06 1746 526 2.90 / 106.17 2 2
5 13 438.08 20 15.18 932 283 3.19 / 106.45 2 2
6 13 33.96 20 15.27 349 107 3.29 / 106.56 2 2
7 8 0.20 165 15.23 293 736 4.03 / 107.29 2 7
Average= 3.58
(KJ/cycle)

Cycle 28 GMT 9/ 3/2022 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.20 454 207 0.21 / 99.64 2 3
2 7 1953.52 32 15.00 2936 1409 1.62 / 101.05 2 2
3 13 1416.48 20 15.03 2257 678 2.29 / 101.73 2 2
4 13 886.68 20 15.11 1558 471 2.77 / 102.20 2 2
5 13 306.76 20 15.23 751 229 2.99 / 102.42 2 2
6 13 28.36 20 15.28 340 104 3.10 / 102.53 2 2
7 8 0.08 165 15.24 293 737 3.84 / 103.27 2 6
Average= 3.56
(KJ/cycle)

Cycle 27 GMT 27/ 2/2022 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 30 15.22 437 200 0.20 / 95.76 2 2
2 7 1892.92 32 15.02 2846 1368 1.57 / 97.13 2 2
3 13 1505.76 20 15.02 2367 711 2.28 / 97.84 2 2
4 13 948.72 20 15.10 1635 494 2.77 / 98.33 2 2
5 13 370.32 20 15.22 835 254 3.03 / 98.59 2 2
6 13 40.08 20 15.28 357 109 3.14 / 98.70 2 2
7 8 -0.08 165 15.25 292 735 3.87 / 99.43 2 5
Average= 3.55
(KJ/cycle)

Cycle 26 GMT 17/ 2/2022 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 15.23 434 198 0.20 / 92.04 2 3
2 3 1015.36 1 15.34 1782 27 0.23 / 92.07 2 2
3 7 1677.60 33 15.09 2557 1273 1.50 / 93.34 2 2
4 13 1548.56 20 15.06 2408 725 2.22 / 94.07 2 2
5 13 944.76 20 15.13 1630 493 2.72 / 94.56 2 2
6 13 216.08 20 15.28 606 185 2.90 / 94.75 2 2
7 13 40.48 20 15.30 352 108 3.01 / 94.85 2 2
8 8 0.04 165 15.27 280 705 3.72 / 95.56 2 6
Average= 3.54
(KJ/cycle)

Cycle 25 GMT 7/ 2/2022 16:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 30 15.24 454 208 0.21 / 88.25 2 3
2 7 1608.12 32 15.12 2482 1201 1.41 / 89.45 2 2
3 13 1485.20 20 15.09 2348 709 2.12 / 90.16 2 2
4 13 909.44 20 15.15 1586 481 2.60 / 90.64 2 2
5 13 300.84 20 15.27 737 225 2.82 / 90.87 2 2
6 13 35.04 20 15.32 349 107 2.93 / 90.98 2 2
7 8 0.00 165 15.28 292 736 3.67 / 91.71 2 7
8 14 0.00 30 15.25 291 133 3.80 / 91.84 3 8
Average= 3.53
(KJ/cycle)

Cycle 24 GMT 28/ 1/2022 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 29 15.24 463 205 0.20 / 84.80 2 3
2 7 1444.56 33 15.17 2259 1131 1.34 / 85.93 2 2
3 13 1341.76 20 15.14 2154 652 1.99 / 86.58 2 2
4 13 808.88 20 15.19 1446 439 2.43 / 87.02 2 2
5 13 214.56 20 15.30 609 186 2.61 / 87.21 2 2
6 13 37.40 20 15.32 352 108 2.72 / 87.31 2 2
7 8 0.08 165 15.29 290 732 3.45 / 88.05 2 8
Average= 3.52
(KJ/cycle)

Cycle 23 GMT 18/ 1/2022 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 29 15.26 452 200 0.20 / 81.37 2 3
2 7 1333.20 32 15.23 2127 1037 1.24 / 82.40 2 2
3 13 1249.16 20 15.19 2030 617 1.85 / 83.02 2 2
4 13 834.96 20 15.22 1486 452 2.31 / 83.47 2 2
5 13 374.00 20 15.28 847 259 2.56 / 83.73 2 2
6 13 34.04 20 15.33 359 110 2.67 / 83.84 2 2
7 8 0.00 165 15.30 298 752 3.43 / 84.59 2 6
Average= 3.52
(KJ/cycle)

Cycle 22 GMT 8/ 1/2022 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 30 15.26 454 208 0.21 / 78.16 3 3
2 7 1263.88 32 15.22 2024 986 1.19 / 79.15 2 2
3 13 1182.52 20 15.19 1939 589 1.78 / 79.74 2 2
4 13 784.04 20 15.22 1417 431 2.21 / 80.17 2 2
5 13 200.64 20 15.32 586 180 2.39 / 80.35 2 2
6 13 22.96 20 15.35 328 101 2.49 / 80.45 2 2
7 8 -0.04 165 15.31 284 717 3.21 / 81.17 2 6
Average= 3.53
(KJ/cycle)

Cycle 21 GMT 29/12/2021 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 30 15.24 452 207 0.21 / 74.88 2 3
2 7 1287.52 32 15.24 2061 1005 1.21 / 75.88 2 2
3 13 1209.68 20 15.18 1973 599 1.81 / 76.48 2 2
4 13 819.32 20 15.20 1464 445 2.26 / 76.93 2 2
5 13 229.88 20 15.31 639 196 2.45 / 77.12 2 2
6 13 23.56 20 15.34 330 101 2.55 / 77.22 2 3
7 8 0.04 165 15.30 290 732 3.28 / 77.95 2 7
Average= 3.54
(KJ/cycle)

Cycle 20 GMT 19/12/2021 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.21 428 195 0.20 / 71.19 2 2
2 7 1591.88 33 15.13 2456 1226 1.42 / 72.41 2 2
3 13 1472.72 20 15.10 2318 700 2.12 / 73.11 2 2
4 13 1027.84 20 15.14 1739 527 2.65 / 73.64 2 2
5 13 267.84 20 15.28 682 208 2.86 / 73.85 2 2
6 13 26.56 20 15.33 334 102 2.96 / 73.95 2 2
7 8 0.12 165 15.30 284 717 3.68 / 74.67 2 7
Average= 3.56
(KJ/cycle)

Cycle 19 GMT 9/12/2021 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 15.22 447 204 0.20 / 67.26 3 3
2 7 2004.08 33 15.00 2970 1470 1.67 / 68.73 2 2
3 13 1567.84 20 15.02 2415 725 2.40 / 69.46 2 2
4 13 985.60 20 15.11 1655 500 2.90 / 69.96 2 2
5 13 272.04 20 15.25 682 208 3.11 / 70.16 2 2
6 13 30.00 20 15.29 338 103 3.21 / 70.27 2 2
7 8 0.04 165 15.26 288 725 3.94 / 70.99 2 7
Average= 3.55
(KJ/cycle)

Cycle 18 GMT 29/11/2021 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 30 15.24 454 208 0.21 / 63.17 2 2
2 7 2008.08 32 15.02 2988 1436 1.64 / 64.61 2 2
3 13 1471.68 20 15.04 2302 692 2.34 / 65.30 2 2
4 13 1038.80 20 15.09 1752 529 2.86 / 65.83 2 2
5 13 431.84 20 15.22 923 281 3.15 / 66.11 2 2
6 13 31.16 20 15.30 337 103 3.25 / 66.21 2 2
7 8 0.20 165 15.26 283 713 3.96 / 66.93 2 7
8 14 0.20 30 15.24 287 131 4.09 / 67.06 3 8
Average= 3.53
(KJ/cycle)

Cycle 17 GMT 19/11/2021 23:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 30 15.27 455 208 0.21 / 59.50 2 3
2 7 1601.32 33 15.14 2465 1232 1.44 / 60.73 2 2
3 13 1475.44 20 15.11 2328 704 2.14 / 61.44 2 2
4 13 893.84 20 15.17 1561 474 2.62 / 61.91 2 2
5 13 297.68 20 15.28 728 222 2.84 / 62.13 2 2
6 13 29.76 20 15.33 335 103 2.94 / 62.23 2 2
7 8 -0.04 165 15.30 289 730 3.67 / 62.96 2 6
Average= 3.50
(KJ/cycle)

Cycle 16 GMT 9/11/2021 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 29 15.25 455 201 0.20 / 56.05 2 3
2 7 1498.52 33 15.17 2335 1169 1.37 / 57.22 2 2
3 13 1386.04 20 15.14 2216 671 2.04 / 57.89 2 2
4 13 936.32 20 15.18 1618 491 2.53 / 58.38 2 2
5 13 204.72 20 15.32 590 181 2.71 / 58.56 2 2
6 8 0.20 165 15.32 289 731 3.44 / 59.29 2 5
Average= 3.49
(KJ/cycle)

Cycle 15 GMT 31/10/2021 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 15.25 454 208 0.21 / 52.34 2 3
2 7 1714.92 32 15.12 2622 1269 1.48 / 53.61 2 2
3 13 1585.44 20 15.08 2455 740 2.22 / 54.35 2 2
4 13 990.76 20 15.15 1687 511 2.73 / 54.86 2 2
5 13 390.36 20 15.27 857 262 2.99 / 55.12 2 2
6 8 0.16 165 15.30 288 727 3.72 / 55.85 2 5
Average= 3.49
(KJ/cycle)

Cycle 14 GMT 21/10/2021 0:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 30 15.23 454 207 0.21 / 48.70 2 2
2 7 1843.88 32 15.06 2770 1335 1.54 / 50.03 2 2
3 13 1452.72 20 15.07 2276 686 2.23 / 50.72 2 2
4 13 872.16 20 15.15 1538 466 2.69 / 51.19 2 2
5 13 296.16 20 15.28 733 224 2.92 / 51.41 2 2
6 8 0.04 165 15.29 286 722 3.64 / 52.13 2 4
Average= 3.48
(KJ/cycle)

Cycle 13 GMT 11/10/2021 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 30 15.26 449 206 0.21 / 44.77 2 3
2 7 2001.96 32 15.04 2971 1430 1.64 / 46.20 2 2
3 13 1583.52 19 15.03 2451 700 2.34 / 46.90 2 2
4 13 1000.84 19 15.12 1701 489 2.82 / 47.39 2 2
5 13 422.92 19 15.22 904 261 3.09 / 47.65 2 2
6 13 57.00 19 15.30 379 110 3.20 / 47.76 2 2
7 8 0.00 165 15.27 290 731 3.93 / 48.49 2 6
Average= 3.46
(KJ/cycle)

Cycle 12 GMT 1/10/2021 2: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 30 15.26 442 202 0.20 / 40.85 2 3
2 7 2003.36 32 15.06 2978 1435 1.64 / 42.28 2 2
3 13 1585.28 19 15.04 2465 704 2.34 / 42.98 2 2
4 13 1008.44 19 15.13 1716 493 2.84 / 43.48 2 2
5 13 426.24 19 15.24 912 264 3.10 / 43.74 2 2
6 13 27.64 19 15.32 332 97 3.20 / 43.84 2 2
7 8 0.20 165 15.30 288 727 3.92 / 44.57 2 6
Average= 3.43
(KJ/cycle)

Cycle 11 GMT 21/ 9/2021 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 29 15.28 446 198 0.20 / 37.01 2 3
2 7 2002.24 33 15.03 2995 1485 1.68 / 38.49 2 2
3 13 1575.08 19 15.06 2456 703 2.39 / 39.19 2 2
4 13 994.20 19 15.14 1688 486 2.87 / 39.68 2 2
5 13 413.20 19 15.25 890 258 3.13 / 39.94 2 2
6 8 0.08 165 15.31 279 705 3.83 / 40.64 2 4
Average= 3.39
(KJ/cycle)

Cycle 10 GMT 11/ 9/2021 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 29 15.28 443 196 0.20 / 33.30 2 3
2 7 2005.56 33 15.04 2984 1481 1.68 / 34.78 2 2
3 13 1442.52 19 15.08 2281 654 2.33 / 35.43 2 2
4 13 893.80 19 15.17 1547 446 2.78 / 35.88 2 2
5 13 325.04 19 15.28 756 219 3.00 / 36.10 2 2
6 8 0.12 165 15.32 282 713 3.71 / 36.81 2 4
Average= 3.35
(KJ/cycle)

Cycle 9 GMT 1/ 9/2021 8:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 29 15.30 448 199 0.20 / 29.29 2 3
2 7 2007.60 36 15.03 2980 1612 1.81 / 30.90 2 2
3 13 1414.48 19 15.10 2213 635 2.45 / 31.54 2 2
4 13 857.56 19 15.18 1491 430 2.88 / 31.97 2 2
5 13 281.08 19 15.29 691 201 3.08 / 32.17 2 2
6 13 12.72 19 15.35 302 88 3.16 / 32.25 2 2
7 8 0.00 165 15.32 283 715 3.88 / 32.97 2 8
8 14 0.00 30 15.30 283 130 4.01 / 33.10 3 7
Average= 3.31
(KJ/cycle)

Cycle 8 GMT 22/ 8/2021 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 29 15.29 427 189 0.19 / 25.49 2 3
2 7 2002.60 35 15.03 2975 1565 1.75 / 27.05 2 2
3 13 1435.08 18 15.11 2267 617 2.37 / 27.67 2 2
4 13 999.28 18 15.15 1693 462 2.83 / 28.13 2 2
5 13 392.24 18 15.29 863 238 3.07 / 28.37 2 2
6 8 0.00 165 15.33 285 721 3.79 / 29.09 2 3
Average= 3.23
(KJ/cycle)

Cycle 7 GMT 12/ 8/2021 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 29 15.30 393 174 0.17 / 21.62 2 3
2 7 2003.68 36 15.03 2950 1596 1.77 / 23.21 2 2
3 13 1414.76 18 15.12 2214 603 2.37 / 23.82 2 2
4 13 981.28 18 15.17 1639 448 2.82 / 24.26 2 2
5 13 392.68 18 15.29 827 228 3.05 / 24.49 2 2
6 13 54.88 18 15.34 362 100 3.15 / 24.59 2 2
7 8 0.20 165 15.32 280 708 3.86 / 25.30 2 6
Average= 3.16
(KJ/cycle)

Cycle 6 GMT 2/ 8/2021 14: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 15.31 407 174 0.17 / 17.97 2 3
2 3 1026.76 1 15.38 1761 27 0.20 / 17.99 2 2
3 7 2001.88 38 15.03 2954 1687 1.89 / 19.68 2 2
4 13 1388.92 18 15.11 2181 593 2.48 / 20.27 2 2
5 13 822.04 18 15.21 1428 391 2.87 / 20.66 2 2
6 13 243.88 18 15.33 608 168 3.04 / 20.83 2 2
7 8 0.24 165 15.34 241 610 3.65 / 21.44 2 6
Average= 3.06
(KJ/cycle)

Cycle 5 GMT 23/ 7/2021 15:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 29 15.33 406 180 0.18 / 14.32 2 3
2 3 954.96 -1 15.64 0 0 0.00 / 14.32 2 3
3 7 2003.88 38 15.02 2955 1687 1.87 / 16.01 2 2
4 13 1418.80 18 15.11 2217 603 2.47 / 16.61 2 2
5 13 835.92 18 15.20 1444 395 2.87 / 17.00 2 2
6 13 248.36 18 15.32 615 170 3.03 / 17.17 2 2
7 8 0.00 165 15.35 244 618 3.65 / 17.79 2 4
Average= 2.97
(KJ/cycle)

Cycle 4 GMT 13/ 7/2021 17:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 28 15.33 407 175 0.17 / 11.20 2 3
2 7 1521.00 38 15.18 2314 1335 1.51 / 12.53 2 2
3 13 1252.44 18 15.20 1975 540 2.05 / 13.07 2 2
4 13 670.28 18 15.27 1210 333 2.38 / 13.40 2 2
5 13 123.68 18 15.37 427 118 2.50 / 13.52 2 2
6 8 0.08 165 15.37 243 616 3.12 / 14.14 2 4
Average= 2.83
(KJ/cycle)

Cycle 3 GMT 12/ 7/2021 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 27 15.33 397 164 0.16 / 7.63 2 3
2 3 1029.56 1 15.39 1773 27 0.19 / 7.66 2 2
3 7 1510.36 74 15.09 2297 2565 2.76 / 10.22 2 2
4 13 283.96 18 15.35 662 183 2.94 / 10.41 2 2
5 8 0.16 165 15.36 243 616 3.56 / 11.02 2 5
Average= 2.76
(KJ/cycle)

Cycle 2 GMT 11/ 7/2021 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 15.33 399 196 0.20 / 4.19 2 2
2 3 840.64 -3 15.63 0 0 0.00 / 4.19 2 2
3 3 964.48 -1 15.67 0 0 0.00 / 4.19 2 2
4 7 1505.88 74 15.08 2287 2552 2.75 / 6.74 2 2
5 13 144.16 18 15.37 452 125 2.87 / 6.86 2 2
6 8 0.16 165 15.36 238 603 3.48 / 7.47 2 4
Average= 2.49
(KJ/cycle)

Cycle 1 GMT 10/ 7/2021 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 27 15.48 370 155 0.15 / 1.53 3 3
2 7 1011.24 74 15.21 1635 1840 1.99 / 3.37 2 2
3 8 0.16 165 15.37 245 621 2.62 / 3.99 2 4
Average= 2.00
(KJ/cycle)

Cycle 0 GMT 10/ 7/2021 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 26 15.60 374 152 0.15 / 0.15 3 3
2 7 123.12 74 15.58 384 443 0.59 / 0.59 3 3
3 8 0.36 240 15.55 209 780 1.37 / 1.37 3 7
Average= 1.37
(KJ/cycle)