Cycle 171 GMT 13/12/2024 23:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 14.94 456 218 0.22 / 658.96 2 3
2 7 2005.40 32 14.85 2962 1408 1.63 / 660.37 2 3
3 13 1610.96 18 14.83 2492 665 2.29 / 661.04 2 3
4 13 1065.80 18 14.86 1753 469 2.76 / 661.51 2 3
5 13 494.00 18 14.94 984 265 3.02 / 661.77 2 3
6 8 0.00 170 15.00 281 717 3.74 / 662.49 2 3
Average= 3.85
(KJ/cycle)

Cycle 170 GMT 4/12/2024 4:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.95 455 218 0.22 / 655.07 2 3
2 7 2005.16 31 14.85 2979 1371 1.59 / 656.45 2 3
3 13 1608.20 18 14.84 2504 669 2.26 / 657.11 2 2
4 13 1059.24 18 14.84 1767 472 2.73 / 657.59 2 3
5 13 488.00 18 14.93 966 260 2.99 / 657.85 2 3
6 8 0.04 170 15.00 287 732 3.72 / 658.58 2 2
7 14 0.04 40 14.97 282 169 3.89 / 658.75 2 3
Average= 3.85
(KJ/cycle)

Cycle 169 GMT 24/11/2024 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 32 14.96 448 214 0.21 / 651.35 2 3
2 7 2005.36 31 14.85 2969 1367 1.58 / 652.71 2 3
3 13 1613.16 18 14.83 2480 662 2.24 / 653.38 2 3
4 13 1186.56 18 14.84 1914 511 2.75 / 653.89 2 3
5 13 466.08 18 14.95 931 251 3.01 / 654.14 2 3
6 8 -0.04 170 15.00 282 719 3.72 / 654.86 2 3
Average= 3.85
(KJ/cycle)

Cycle 168 GMT 14/11/2024 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 32 14.94 453 217 0.22 / 647.65 2 3
2 7 2004.00 31 14.84 2968 1365 1.58 / 649.01 2 3
3 13 1602.48 18 14.83 2468 659 2.24 / 649.67 2 3
4 13 1164.20 18 14.84 1888 504 2.75 / 650.18 2 3
5 13 450.88 18 14.95 916 246 2.99 / 650.42 2 3
6 8 0.36 170 15.01 278 709 3.70 / 651.13 2 3
Average= 3.85
(KJ/cycle)

Cycle 167 GMT 4/11/2024 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 32 14.94 474 227 0.23 / 643.76 2 3
2 7 2004.64 31 14.83 2989 1374 1.60 / 645.14 2 3
3 13 1725.96 18 14.80 2647 705 2.31 / 645.84 2 3
4 13 1139.64 18 14.83 1882 502 2.81 / 646.34 2 3
5 13 550.60 18 14.92 1066 286 3.09 / 646.63 2 3
6 13 20.52 18 15.04 323 87 3.18 / 646.72 2 3
7 8 -0.04 170 15.00 280 714 3.90 / 647.43 2 3
Average= 3.85
(KJ/cycle)

Cycle 166 GMT 26/10/2024 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 32 14.94 460 220 0.22 / 639.77 2 3
2 7 2012.80 31 14.84 2981 1371 1.59 / 641.14 2 3
3 13 1613.20 18 14.82 2487 663 2.25 / 641.80 2 2
4 13 1173.80 18 14.84 1900 508 2.76 / 642.31 2 3
5 13 576.80 18 14.92 1101 296 3.06 / 642.61 2 3
6 8 0.40 170 15.00 293 747 3.81 / 643.35 2 3
7 14 0.40 40 14.98 303 182 3.99 / 643.54 2 3
Average= 3.85
(KJ/cycle)

Cycle 165 GMT 16/10/2024 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 14.95 451 216 0.22 / 635.96 2 3
2 7 2004.08 31 14.85 2982 1373 1.59 / 637.33 2 3
3 13 1725.36 18 14.82 2642 705 2.29 / 638.04 2 3
4 13 1143.16 18 14.84 1879 502 2.80 / 638.54 2 3
5 13 553.88 18 14.94 1055 284 3.08 / 638.82 2 3
6 8 0.00 170 15.01 284 725 3.80 / 639.55 2 3
Average= 3.85
(KJ/cycle)

Cycle 164 GMT 6/10/2024 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.96 473 226 0.23 / 632.17 2 3
2 7 2003.72 31 14.85 2969 1367 1.59 / 633.54 2 3
3 13 1608.24 18 14.83 2489 664 2.26 / 634.20 2 3
4 13 1182.16 18 14.84 1931 516 2.77 / 634.72 2 3
5 13 589.24 18 14.92 1109 298 3.07 / 635.02 2 3
6 8 0.08 170 15.00 285 727 3.80 / 635.75 2 3
Average= 3.85
(KJ/cycle)

Cycle 163 GMT 26/ 9/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 32 14.95 457 219 0.22 / 628.43 2 3
2 7 2004.08 31 14.85 2973 1369 1.59 / 629.80 2 3
3 13 1607.20 18 14.83 2485 663 2.25 / 630.47 2 3
4 13 1180.20 18 14.84 1908 510 2.76 / 630.98 2 3
5 13 459.16 18 14.95 920 248 3.01 / 631.22 2 3
6 8 -0.08 170 15.01 284 725 3.73 / 631.95 2 7
Average= 3.85
(KJ/cycle)

Cycle 162 GMT 16/ 9/2024 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 32 14.96 442 212 0.21 / 624.64 2 3
2 7 2003.88 31 14.87 2956 1363 1.57 / 626.00 2 3
3 13 1735.52 18 14.84 2629 702 2.28 / 626.70 2 3
4 13 1151.08 18 14.86 1874 501 2.78 / 627.20 2 3
5 13 558.08 18 14.94 1073 289 3.07 / 627.49 2 3
6 8 0.04 170 15.02 283 723 3.79 / 628.21 2 4
Average= 3.85
(KJ/cycle)

Cycle 161 GMT 7/ 9/2024 1:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 14.96 459 220 0.22 / 620.58 2 3
2 7 2006.56 31 14.85 2971 1368 1.59 / 621.94 2 3
3 13 1734.28 18 14.82 2658 709 2.30 / 622.65 2 3
4 13 1149.96 18 14.86 1873 501 2.80 / 623.15 2 3
5 13 562.32 18 14.94 1070 288 3.09 / 623.44 2 3
6 13 28.84 18 15.04 341 92 3.18 / 623.53 2 3
7 8 0.24 170 15.01 283 722 3.90 / 624.26 2 4
8 14 0.24 40 14.99 283 170 4.07 / 624.43 3 4
Average= 3.85
(KJ/cycle)

Cycle 160 GMT 28/ 8/2024 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 32 14.96 471 225 0.23 / 616.56 2 3
2 7 2005.60 31 14.87 2979 1373 1.60 / 617.94 2 3
3 13 1619.28 18 14.83 2527 675 2.27 / 618.61 2 3
4 13 1189.40 18 14.84 1953 522 2.79 / 619.13 2 3
5 13 595.56 18 14.93 1128 303 3.10 / 619.44 2 3
6 8 0.04 170 15.02 292 746 3.84 / 620.18 2 3
7 14 0.04 40 14.99 293 176 4.02 / 620.36 2 4
Average= 3.85
(KJ/cycle)

Cycle 159 GMT 18/ 8/2024 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 14.96 442 212 0.21 / 612.71 2 3
2 7 2004.44 31 14.88 2977 1373 1.58 / 614.09 2 3
3 13 1729.16 18 14.83 2644 706 2.29 / 614.79 2 3
4 13 1150.96 18 14.86 1885 504 2.79 / 615.30 2 3
5 13 571.16 18 14.94 1103 297 3.09 / 615.59 2 3
6 8 0.20 170 15.02 291 743 3.83 / 616.34 3 3
Average= 3.85
(KJ/cycle)

Cycle 158 GMT 8/ 8/2024 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 32 14.95 439 210 0.21 / 608.69 2 3
2 7 2007.32 31 14.86 2967 1367 1.58 / 610.06 2 3
3 13 1736.60 18 14.82 2649 707 2.28 / 610.77 2 2
4 13 1147.40 18 14.85 1878 502 2.79 / 611.27 2 3
5 13 565.76 18 14.94 1068 287 3.07 / 611.56 2 3
6 13 15.32 18 15.04 303 82 3.15 / 611.64 2 2
7 8 0.20 170 15.01 274 699 3.85 / 612.34 2 2
8 14 0.20 40 14.99 276 165 4.02 / 612.50 2 6
Average= 3.85
(KJ/cycle)

Cycle 157 GMT 29/ 7/2024 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 32 14.96 456 218 0.22 / 604.68 2 3
2 7 2002.96 31 14.86 2970 1368 1.59 / 606.05 2 3
3 13 1728.16 18 14.82 2625 700 2.29 / 606.75 2 3
4 13 1141.04 18 14.86 1851 495 2.78 / 607.24 2 3
5 13 555.88 18 14.94 1055 284 3.07 / 607.53 2 3
6 13 25.08 18 15.04 315 85 3.15 / 607.61 2 3
7 8 0.04 170 15.01 277 707 3.86 / 608.32 3 2
8 14 0.04 40 14.98 276 165 4.02 / 608.48 2 3
Average= 3.85
(KJ/cycle)

Cycle 156 GMT 20/ 7/2024 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 32 14.95 451 216 0.22 / 600.80 2 3
2 7 2013.28 31 14.86 2983 1374 1.59 / 602.17 2 3
3 13 1614.36 18 14.84 2485 664 2.25 / 602.84 2 2
4 13 1063.96 18 14.87 1762 472 2.73 / 603.31 2 2
5 13 495.68 18 14.96 973 262 2.99 / 603.57 2 3
6 8 -0.08 170 15.03 283 723 3.71 / 604.29 2 3
7 14 -0.08 40 15.00 278 167 3.88 / 604.46 2 4
Average= 3.85
(KJ/cycle)

Cycle 155 GMT 10/ 7/2024 7:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.97 455 218 0.22 / 597.01 2 3
2 7 2004.80 31 14.86 2970 1368 1.59 / 598.38 2 3
3 13 1618.36 18 14.84 2495 666 2.25 / 599.04 2 3
4 13 1068.40 18 14.87 1767 473 2.73 / 599.52 2 3
5 13 483.32 18 14.95 963 259 2.98 / 599.78 2 3
6 13 33.32 18 15.04 334 90 3.08 / 599.87 2 3
7 8 -0.12 170 15.00 281 717 3.79 / 600.58 2 3
Average= 3.85
(KJ/cycle)

Cycle 154 GMT 30/ 6/2024 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 32 14.95 457 219 0.22 / 593.31 2 3
2 7 2005.08 31 14.86 2977 1371 1.59 / 594.69 2 3
3 13 1607.28 18 14.84 2477 662 2.25 / 595.35 2 3
4 13 1055.32 18 14.87 1748 468 2.72 / 595.82 2 2
5 13 482.40 18 14.95 961 259 2.98 / 596.07 2 3
6 8 0.24 170 15.02 281 718 3.70 / 596.79 2 3
Average= 3.85
(KJ/cycle)

Cycle 153 GMT 20/ 6/2024 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 14.97 449 215 0.22 / 589.45 2 3
2 7 2003.28 31 14.86 2961 1364 1.58 / 590.81 2 3
3 13 1601.04 18 14.85 2463 658 2.24 / 591.47 2 3
4 13 1050.36 18 14.88 1747 468 2.71 / 591.94 2 3
5 13 470.56 18 14.96 952 256 2.96 / 592.19 2 3
6 8 0.16 170 15.02 286 730 3.69 / 592.92 2 3
7 14 0.16 40 14.99 285 171 3.86 / 593.10 2 6
Average= 3.85
(KJ/cycle)

Cycle 152 GMT 10/ 6/2024 22: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 32 14.96 447 214 0.21 / 585.66 2 3
2 7 2005.76 31 14.87 2964 1366 1.58 / 587.03 2 3
3 13 1619.16 18 14.84 2497 667 2.25 / 587.69 2 3
4 13 1192.80 18 14.86 1934 517 2.76 / 588.21 2 3
5 13 602.24 18 14.93 1130 304 3.07 / 588.52 2 3
6 8 0.24 170 15.02 281 718 3.79 / 589.23 2 3
Average= 3.85
(KJ/cycle)

Cycle 151 GMT 1/ 6/2024 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 14.95 442 211 0.21 / 581.72 2 3
2 7 2013.84 31 14.87 2980 1374 1.59 / 583.09 2 3
3 13 1744.36 18 14.83 2664 711 2.30 / 583.80 2 3
4 13 1158.04 18 14.86 1895 507 2.80 / 584.31 2 3
5 13 454.32 18 14.98 922 249 3.05 / 584.56 2 3
6 8 -0.12 170 15.03 282 721 3.77 / 585.28 2 4
7 14 -0.12 40 15.00 282 169 3.94 / 585.45 2 3
Average= 3.85
(KJ/cycle)

Cycle 150 GMT 22/ 5/2024 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 32 14.96 449 215 0.21 / 577.87 2 3
2 7 2003.08 32 14.86 2972 1413 1.63 / 579.29 2 3
3 13 1729.88 18 14.83 2657 709 2.34 / 580.00 2 3
4 13 1136.20 18 14.86 1860 498 2.83 / 580.49 2 3
5 13 550.12 18 14.95 1063 286 3.12 / 580.78 2 3
6 8 0.16 170 15.02 284 725 3.85 / 581.51 2 2
Average= 3.85
(KJ/cycle)

Cycle 149 GMT 12/ 5/2024 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 32 14.97 446 214 0.21 / 574.15 2 3
2 7 2005.36 31 14.88 2971 1370 1.58 / 575.52 2 3
3 13 1615.96 18 14.85 2487 665 2.25 / 576.18 2 3
4 13 1186.88 18 14.86 1921 514 2.76 / 576.70 2 3
5 13 463.44 18 14.97 933 251 3.01 / 576.95 2 3
6 8 0.12 170 15.02 279 712 3.73 / 577.66 2 3
Average= 3.85
(KJ/cycle)

Cycle 148 GMT 2/ 5/2024 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 32 14.96 454 217 0.22 / 570.27 2 3
2 7 2003.96 31 14.85 2970 1367 1.58 / 571.64 2 3
3 13 1604.80 18 14.85 2460 658 2.24 / 572.29 2 3
4 13 1171.80 18 14.87 1910 511 2.75 / 572.80 2 3
5 13 443.28 18 14.97 908 245 3.00 / 573.05 2 3
6 8 -0.12 170 15.03 281 718 3.72 / 573.77 2 3
7 14 -0.12 40 15.00 276 166 3.88 / 573.93 2 3
Average= 3.85
(KJ/cycle)

Cycle 147 GMT 22/ 4/2024 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 32 14.96 458 219 0.22 / 566.43 2 3
2 7 2003.36 32 14.86 2964 1409 1.63 / 567.84 2 2
3 13 1610.16 18 14.84 2472 660 2.29 / 568.50 2 3
4 13 1175.52 18 14.86 1897 507 2.80 / 569.01 2 3
5 13 454.52 18 14.96 922 248 3.04 / 569.25 2 3
6 13 28.56 18 15.05 320 87 3.13 / 569.34 2 2
7 8 0.08 170 15.02 278 710 3.84 / 570.05 2 3
Average= 3.85
(KJ/cycle)

Cycle 146 GMT 13/ 4/2024 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 14.95 456 218 0.22 / 562.63 2 3
2 7 2012.44 31 14.87 2978 1373 1.59 / 564.00 2 3
3 13 1601.56 18 14.86 2458 657 2.25 / 564.66 2 3
4 13 1168.00 18 14.86 1897 507 2.76 / 565.17 2 3
5 13 452.08 18 14.97 914 246 3.00 / 565.42 2 3
6 13 27.40 18 15.05 321 87 3.09 / 565.50 2 2
7 8 -0.12 170 15.02 277 707 3.80 / 566.21 2 3
Average= 3.85
(KJ/cycle)

Cycle 145 GMT 3/ 4/2024 8:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 32 14.95 460 220 0.22 / 558.89 2 3
2 7 2003.96 31 14.86 2954 1361 1.58 / 560.26 2 3
3 13 1604.80 18 14.85 2477 662 2.24 / 560.92 2 3
4 13 1172.64 18 14.86 1897 507 2.75 / 561.43 2 3
5 13 445.92 18 14.97 921 248 3.00 / 561.67 2 3
6 8 0.16 170 15.02 290 740 3.74 / 562.41 3 3
Average= 3.85
(KJ/cycle)

Cycle 144 GMT 24/ 3/2024 13:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 32 14.95 465 222 0.22 / 555.03 2 3
2 7 2010.88 32 14.86 2983 1418 1.64 / 556.45 2 2
3 13 1614.96 18 14.85 2484 664 2.30 / 557.11 2 3
4 13 1060.12 18 14.88 1761 472 2.78 / 557.58 2 3
5 13 487.96 18 14.96 973 262 3.04 / 557.84 2 3
6 13 33.32 18 15.05 344 93 3.13 / 557.94 2 3
7 8 0.16 170 15.02 289 738 3.87 / 558.67 2 3
Average= 3.85
(KJ/cycle)

Cycle 143 GMT 14/ 3/2024 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.96 452 216 0.22 / 551.13 2 3
2 7 2004.52 31 14.86 2978 1372 1.59 / 552.50 2 3
3 13 1604.64 18 14.85 2480 663 2.25 / 553.17 2 3
4 13 1173.36 18 14.86 1928 516 2.77 / 553.68 2 3
5 13 568.88 18 14.94 1088 293 3.06 / 553.98 2 3
6 13 22.52 18 15.06 336 91 3.15 / 554.07 2 3
7 8 0.08 170 15.02 289 738 3.89 / 554.81 2 4
Average= 3.85
(KJ/cycle)

Cycle 142 GMT 4/ 3/2024 23:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 32 14.97 444 213 0.21 / 547.30 2 3
2 7 2003.96 31 14.86 2988 1376 1.59 / 548.68 2 3
3 13 1607.08 18 14.85 2473 661 2.25 / 549.34 2 3
4 13 1168.12 18 14.87 1906 510 2.76 / 549.85 2 3
5 13 442.32 18 14.97 919 248 3.01 / 550.10 2 3
6 13 29.28 18 15.05 337 91 3.10 / 550.19 2 3
7 8 0.08 170 15.01 286 730 3.83 / 550.92 2 3
Average= 3.85
(KJ/cycle)

Cycle 141 GMT 24/ 2/2024 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 14.97 454 217 0.22 / 543.47 2 3
2 7 2006.84 31 14.86 2966 1366 1.58 / 544.84 2 3
3 13 1600.64 18 14.85 2486 665 2.25 / 545.50 2 3
4 13 1164.00 18 14.86 1897 507 2.76 / 546.01 2 3
5 13 443.92 18 14.98 922 249 3.00 / 546.26 2 3
6 13 26.28 18 15.06 344 93 3.10 / 546.35 2 3
7 8 0.08 170 15.02 288 735 3.83 / 547.09 2 3
Average= 3.85
(KJ/cycle)

Cycle 140 GMT 14/ 2/2024 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 32 14.96 468 224 0.22 / 539.55 2 3
2 7 2013.16 31 14.89 2976 1374 1.60 / 540.92 2 3
3 13 1737.00 18 14.83 2659 710 2.31 / 541.63 2 3
4 13 1147.00 18 14.88 1886 505 2.81 / 542.14 2 3
5 13 560.20 18 14.95 1090 293 3.11 / 542.43 2 3
6 13 23.84 18 15.07 337 91 3.20 / 542.52 2 3
7 8 0.16 170 15.03 287 733 3.93 / 543.25 3 4
Average= 3.85
(KJ/cycle)

Cycle 139 GMT 4/ 2/2024 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 32 14.96 452 216 0.22 / 535.68 2 3
2 7 2003.36 31 14.88 2979 1374 1.59 / 537.05 2 3
3 13 1613.12 18 14.86 2498 668 2.26 / 537.72 2 3
4 13 1184.52 18 14.87 1924 515 2.77 / 538.24 2 3
5 13 465.96 18 14.97 950 256 3.03 / 538.49 2 3
6 13 36.40 18 15.06 349 95 3.12 / 538.59 2 3
7 8 0.08 170 15.02 289 738 3.86 / 539.32 2 4
Average= 3.85
(KJ/cycle)

Cycle 138 GMT 25/ 1/2024 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 14.96 456 218 0.22 / 531.67 2 3
2 7 2003.64 31 14.88 2970 1370 1.59 / 533.04 2 3
3 13 1612.24 18 14.86 2494 667 2.26 / 533.71 2 3
4 13 1180.56 18 14.86 1916 512 2.77 / 534.22 2 3
5 13 460.92 18 14.97 937 252 3.02 / 534.47 2 3
6 13 29.56 18 15.06 345 94 3.11 / 534.57 2 3
7 8 0.04 170 15.02 284 725 3.84 / 535.29 2 3
8 14 0.04 40 15.00 284 170 4.01 / 535.46 3 3
Average= 3.85
(KJ/cycle)

Cycle 137 GMT 15/ 1/2024 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 32 14.95 461 221 0.22 / 527.83 2 3
2 7 2004.08 31 14.87 2967 1368 1.59 / 529.20 2 3
3 13 1603.24 18 14.85 2487 665 2.25 / 529.86 2 3
4 13 1164.96 18 14.86 1908 510 2.76 / 530.37 2 3
5 13 441.12 18 14.97 922 248 3.01 / 530.62 2 3
6 13 24.00 18 15.05 330 89 3.10 / 530.71 2 3
7 8 0.04 170 15.02 291 743 3.84 / 531.45 2 3
Average= 3.85
(KJ/cycle)

Cycle 136 GMT 5/ 1/2024 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 32 14.95 454 217 0.22 / 524.01 2 3
2 7 2004.56 32 14.87 2981 1418 1.64 / 525.43 2 3
3 13 1604.64 18 14.85 2479 663 2.30 / 526.09 2 3
4 13 1171.56 18 14.86 1906 510 2.81 / 526.60 2 3
5 13 446.80 18 14.97 922 248 3.06 / 526.85 2 3
6 8 0.16 170 15.01 298 760 3.82 / 527.61 2 3
Average= 3.85
(KJ/cycle)

Cycle 135 GMT 26/12/2023 23:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 32 14.96 470 225 0.22 / 520.17 2 3
2 3 1017.84 1 15.14 1728 26 0.25 / 520.20 2 3
3 7 2004.48 31 14.87 2971 1370 1.62 / 521.57 2 3
4 13 1598.28 18 14.85 2475 662 2.28 / 522.23 2 3
5 13 1055.04 18 14.88 1756 470 2.75 / 522.70 2 3
6 13 482.92 18 14.96 966 260 3.01 / 522.96 2 3
7 13 27.12 18 15.05 330 89 3.10 / 523.05 2 3
8 8 0.20 170 15.01 290 740 3.84 / 523.79 2 3
Average= 3.85
(KJ/cycle)

Cycle 134 GMT 17/12/2023 1:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 32 14.95 468 224 0.22 / 516.26 3 3
2 7 2003.32 32 14.87 2982 1419 1.64 / 517.67 2 3
3 13 1597.48 18 14.85 2494 667 2.31 / 518.34 2 3
4 13 1170.28 18 14.86 1916 512 2.82 / 518.85 2 3
5 13 442.20 18 14.98 934 252 3.07 / 519.11 2 3
6 13 24.60 18 15.05 343 93 3.17 / 519.20 2 3
7 8 -0.08 170 15.02 294 751 3.92 / 519.95 2 6
Average= 3.85
(KJ/cycle)

Cycle 133 GMT 7/12/2023 3:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.97 453 217 0.22 / 512.34 2 3
2 7 2003.24 31 14.87 2988 1377 1.59 / 513.71 2 4
3 13 1603.92 18 14.85 2499 668 2.26 / 514.38 2 3
4 13 1049.20 18 14.89 1745 468 2.73 / 514.85 2 3
5 13 477.00 18 14.97 965 260 2.99 / 515.11 2 4
6 8 -0.16 170 15.03 293 749 3.74 / 515.86 2 3
7 14 -0.16 40 15.00 289 173 3.91 / 516.03 2 3
Average= 3.85
(KJ/cycle)

Cycle 132 GMT 27/11/2023 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 32 14.97 460 220 0.22 / 508.59 2 3
2 7 2003.84 31 14.88 2976 1373 1.59 / 509.96 2 3
3 13 1603.60 18 14.86 2494 667 2.26 / 510.63 2 3
4 13 1054.84 18 14.89 1772 475 2.74 / 511.10 2 3
5 13 470.16 18 14.98 957 258 2.99 / 511.36 2 3
6 8 0.00 170 15.03 296 756 3.75 / 512.12 2 3
Average= 3.85
(KJ/cycle)

Cycle 131 GMT 17/11/2023 8:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 32 14.98 460 221 0.22 / 504.69 2 3
2 7 2003.36 31 14.86 2978 1372 1.59 / 506.06 2 3
3 13 1599.32 18 14.85 2484 664 2.26 / 506.73 2 3
4 13 1046.64 18 14.88 1751 469 2.73 / 507.20 2 3
5 13 466.72 18 14.98 950 256 2.98 / 507.45 2 3
6 8 0.28 170 15.04 289 739 3.72 / 508.19 2 3
7 14 0.28 40 15.01 295 177 3.90 / 508.37 2 3
Average= 3.85
(KJ/cycle)

Cycle 130 GMT 7/11/2023 10:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 14.97 455 218 0.22 / 500.95 2 3
2 7 2005.28 32 14.86 2963 1409 1.63 / 502.35 2 3
3 13 1605.44 18 14.85 2477 662 2.29 / 503.02 2 3
4 13 1047.52 18 14.89 1737 466 2.75 / 503.48 2 3
5 13 474.08 18 14.98 951 256 3.01 / 503.74 2 3
6 8 0.24 170 15.04 287 734 3.74 / 504.47 2 3
Average= 3.85
(KJ/cycle)

Cycle 129 GMT 28/10/2023 12:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 14.97 469 225 0.22 / 497.00 2 3
2 7 2005.72 32 14.87 2978 1417 1.64 / 498.42 2 3
3 13 1605.00 18 14.86 2478 663 2.30 / 499.08 2 3
4 13 1055.20 18 14.90 1754 470 2.77 / 499.55 2 3
5 13 479.16 18 14.98 964 260 3.03 / 499.81 2 3
6 8 -0.08 170 15.04 291 744 3.78 / 500.56 2 3
7 14 -0.08 40 15.01 286 172 3.95 / 500.73 2 4
Average= 3.85
(KJ/cycle)

Cycle 128 GMT 18/10/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 32 14.99 459 220 0.22 / 493.23 2 3
2 7 2003.48 31 14.87 2986 1376 1.60 / 494.60 2 3
3 13 1598.52 18 14.85 2484 664 2.26 / 495.27 2 2
4 13 1164.16 18 14.86 1907 510 2.77 / 495.78 2 3
5 13 440.40 18 14.98 923 249 3.02 / 496.03 2 3
6 8 0.08 170 15.04 293 749 3.77 / 496.78 2 3
Average= 3.85
(KJ/cycle)

Cycle 127 GMT 8/10/2023 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 32 14.97 484 232 0.23 / 489.48 2 3
2 7 2003.80 31 14.86 2974 1370 1.60 / 490.85 2 3
3 13 1597.16 18 14.85 2495 667 2.27 / 491.52 2 3
4 13 1058.52 18 14.88 1774 475 2.74 / 492.00 2 3
5 13 484.52 18 14.97 977 263 3.01 / 492.26 2 4
6 8 0.20 170 15.04 293 749 3.76 / 493.01 2 3
Average= 3.85
(KJ/cycle)

Cycle 126 GMT 28/ 9/2023 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 14.97 471 226 0.23 / 485.66 2 3
2 7 2003.68 31 14.89 2987 1379 1.60 / 487.04 2 3
3 13 1617.20 18 14.85 2507 670 2.27 / 487.71 2 3
4 13 1180.36 18 14.88 1925 516 2.79 / 488.22 2 3
5 13 457.92 18 14.99 948 256 3.05 / 488.48 2 4
6 8 0.28 170 15.04 303 775 3.82 / 489.25 2 3
Average= 3.85
(KJ/cycle)

Cycle 125 GMT 18/ 9/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 14.99 462 222 0.22 / 481.69 2 3
2 7 2012.00 31 14.88 2991 1380 1.60 / 483.07 2 3
3 13 1593.20 18 14.86 2488 665 2.27 / 483.74 2 4
4 13 1162.12 18 14.88 1908 511 2.78 / 484.25 2 3
5 13 437.48 18 15.00 916 247 3.03 / 484.50 2 3
6 8 -0.20 170 15.04 295 754 3.78 / 485.25 2 3
7 14 -0.20 40 15.01 301 181 3.96 / 485.43 2 4
Average= 3.85
(KJ/cycle)

Cycle 124 GMT 9/ 9/2023 0:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 32 14.96 468 224 0.22 / 477.90 2 3
2 7 2013.96 31 14.89 2999 1384 1.61 / 479.28 2 3
3 13 1606.48 18 14.87 2483 665 2.27 / 479.95 2 3
4 13 1168.52 18 14.88 1920 514 2.79 / 480.46 2 3
5 13 447.60 18 15.00 927 250 3.04 / 480.71 2 3
6 8 0.20 170 15.05 297 760 3.80 / 481.47 2 3
Average= 3.85
(KJ/cycle)

Cycle 123 GMT 30/ 8/2023 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 32 14.98 468 224 0.22 / 473.75 2 3
2 7 2013.84 31 14.88 2989 1379 1.60 / 475.13 2 3
3 13 1627.80 18 14.86 2524 675 2.28 / 475.80 2 3
4 13 1190.88 18 14.87 1946 521 2.80 / 476.33 2 3
5 13 599.20 18 14.95 1141 307 3.11 / 476.63 2 3
6 13 60.88 18 15.06 401 109 3.21 / 476.74 2 3
7 8 0.08 170 15.03 296 756 3.97 / 477.50 2 3
8 14 0.08 40 15.01 293 176 4.15 / 477.67 2 3
Average= 3.85
(KJ/cycle)

Cycle 122 GMT 20/ 8/2023 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 32 14.98 466 223 0.22 / 469.71 2 3
2 7 2003.80 31 14.90 2983 1378 1.60 / 471.09 2 3
3 13 1728.16 18 14.87 2641 707 2.31 / 471.80 2 3
4 13 1132.16 18 14.89 1862 499 2.81 / 472.30 2 3
5 13 543.80 18 14.98 1056 285 3.09 / 472.58 2 3
6 8 0.12 170 15.05 300 768 3.86 / 473.35 2 3
7 14 0.12 40 15.02 298 179 4.04 / 473.53 3 3
Average= 3.85
(KJ/cycle)

Cycle 121 GMT 10/ 8/2023 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 14.95 473 226 0.23 / 465.89 2 3
2 7 2005.12 31 14.88 2974 1372 1.60 / 467.26 2 3
3 13 1604.44 18 14.87 2471 661 2.26 / 467.93 2 3
4 13 1175.04 18 14.88 1904 510 2.77 / 468.44 2 3
5 13 575.80 18 14.96 1102 297 3.07 / 468.73 2 3
6 8 -0.12 170 15.03 296 756 3.82 / 469.49 2 3
Average= 3.85
(KJ/cycle)

Cycle 120 GMT 31/ 7/2023 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 32 14.97 467 224 0.22 / 461.86 2 3
2 7 2012.92 31 14.87 2988 1377 1.60 / 463.24 2 3
3 13 1613.80 18 14.86 2487 665 2.27 / 463.90 2 3
4 13 1185.20 18 14.87 1919 514 2.78 / 464.42 2 3
5 13 602.92 18 14.95 1133 305 3.08 / 464.72 2 3
6 8 0.28 170 15.03 299 764 3.85 / 465.49 2 3
7 14 0.28 40 15.00 298 179 4.03 / 465.67 2 3
Average= 3.85
(KJ/cycle)

Cycle 119 GMT 21/ 7/2023 11:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 32 14.97 477 229 0.23 / 457.92 2 3
2 7 2013.96 31 14.88 3011 1389 1.62 / 459.31 2 3
3 13 1613.12 18 14.86 2507 671 2.29 / 459.98 2 3
4 13 1067.36 18 14.89 1778 477 2.76 / 460.46 2 3
5 13 504.76 18 14.97 999 269 3.03 / 460.73 2 3
6 8 0.20 170 15.03 289 738 3.77 / 461.47 3 3
7 14 0.20 40 15.01 285 171 3.94 / 461.64 2 3
Average= 3.85
(KJ/cycle)

Cycle 118 GMT 11/ 7/2023 13:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 14.97 470 225 0.23 / 453.96 2 3
2 7 2005.00 31 14.87 2977 1372 1.60 / 455.33 2 3
3 13 1596.68 18 14.87 2477 663 2.26 / 455.99 2 3
4 13 1164.12 18 14.87 1902 509 2.77 / 456.50 2 3
5 13 438.08 18 14.98 932 251 3.02 / 456.75 2 3
6 8 -0.12 170 15.03 299 764 3.78 / 457.52 2 3
7 14 -0.12 40 15.00 299 179 3.96 / 457.69 2 3
Average= 3.85
(KJ/cycle)

Cycle 117 GMT 1/ 7/2023 15:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 32 14.97 473 227 0.23 / 450.16 2 3
2 7 2010.44 31 14.88 2979 1374 1.60 / 451.53 2 3
3 13 1727.36 18 14.85 2631 703 2.30 / 452.24 2 3
4 13 1136.44 18 14.88 1860 498 2.80 / 452.74 2 3
5 13 423.76 18 14.99 899 243 3.04 / 452.98 2 3
6 8 0.40 170 15.04 294 752 3.80 / 453.73 2 4
Average= 3.85
(KJ/cycle)

Cycle 116 GMT 21/ 6/2023 18:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 32 14.98 471 226 0.23 / 446.33 2 3
2 7 2012.00 31 14.89 2984 1377 1.60 / 447.71 2 3
3 13 1736.96 18 14.86 2643 707 2.31 / 448.41 2 3
4 13 1158.76 18 14.89 1894 508 2.82 / 448.92 2 3
5 13 445.04 18 14.98 923 249 3.07 / 449.17 2 3
6 8 0.40 170 15.04 299 764 3.83 / 449.93 2 3
Average= 3.85
(KJ/cycle)

Cycle 115 GMT 11/ 6/2023 20:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 32 14.97 461 221 0.22 / 442.50 2 3
2 7 2003.72 31 14.90 2970 1372 1.59 / 443.87 2 3
3 13 1613.56 18 14.87 2490 666 2.26 / 444.53 2 3
4 13 1181.48 18 14.88 1936 519 2.78 / 445.05 2 3
5 13 582.16 18 14.96 1109 299 3.08 / 445.35 2 3
6 8 -0.12 170 15.03 294 751 3.83 / 446.10 2 3
Average= 3.85
(KJ/cycle)

Cycle 114 GMT 1/ 6/2023 22:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 32 14.97 461 221 0.22 / 438.72 2 3
2 7 2011.92 31 14.88 2966 1368 1.59 / 440.09 2 3
3 13 1610.84 18 14.86 2487 665 2.25 / 440.76 2 3
4 13 1175.44 18 14.88 1925 516 2.77 / 441.27 2 3
5 13 446.12 18 14.98 919 248 3.02 / 441.52 2 3
6 8 0.20 170 15.03 295 754 3.77 / 442.28 2 3
Average= 3.85
(KJ/cycle)

Cycle 113 GMT 23/ 5/2023 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 32 14.97 481 230 0.23 / 434.98 3 3
2 7 2011.96 31 14.88 2970 1370 1.60 / 436.35 2 3
3 13 1615.36 18 14.87 2481 664 2.26 / 437.02 2 3
4 13 1063.68 18 14.89 1776 476 2.74 / 437.49 2 3
5 13 483.44 18 14.98 969 261 3.00 / 437.76 2 3
6 8 0.08 170 15.03 293 749 3.75 / 438.50 2 3
Average= 3.85
(KJ/cycle)

Cycle 112 GMT 13/ 5/2023 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 32 14.97 451 216 0.22 / 430.97 2 3
2 7 2012.84 31 14.89 2987 1379 1.59 / 432.34 2 3
3 13 1607.92 18 14.86 2512 672 2.27 / 433.02 2 4
4 13 1050.32 18 14.90 1762 473 2.74 / 433.49 2 3
5 13 469.04 18 14.98 955 258 3.00 / 433.75 2 3
6 13 23.56 18 15.07 337 91 3.09 / 433.84 2 3
7 8 0.04 170 15.04 290 741 3.83 / 434.58 3 4
8 14 0.04 40 15.01 290 174 4.00 / 434.75 3 3
Average= 3.85
(KJ/cycle)

Cycle 111 GMT 3/ 5/2023 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 32 14.99 468 224 0.22 / 427.06 2 3
2 7 2004.16 31 14.88 2977 1373 1.60 / 428.43 2 3
3 13 1601.64 18 14.87 2465 660 2.26 / 429.09 2 3
4 13 1043.92 18 14.90 1742 467 2.72 / 429.56 2 3
5 13 456.04 18 14.99 940 254 2.98 / 429.81 2 3
6 8 0.00 170 15.04 296 757 3.74 / 430.57 2 3
7 14 0.00 40 15.01 300 180 3.92 / 430.75 2 3
Average= 3.85
(KJ/cycle)

Cycle 110 GMT 23/ 4/2023 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 14.97 470 225 0.23 / 423.31 2 3
2 7 2012.36 31 14.89 2985 1378 1.60 / 424.69 2 3
3 13 1613.04 18 14.87 2479 664 2.27 / 425.35 2 3
4 13 1058.96 18 14.89 1758 471 2.74 / 425.82 2 3
5 13 475.44 18 14.99 979 264 3.00 / 426.08 2 3
6 8 0.28 170 15.05 293 750 3.75 / 426.83 2 4
Average= 3.85
(KJ/cycle)

Cycle 109 GMT 13/ 4/2023 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 32 14.97 471 226 0.23 / 419.40 2 3
2 7 2003.48 31 14.89 2972 1372 1.60 / 420.77 2 3
3 13 1604.72 18 14.88 2483 665 2.26 / 421.44 2 3
4 13 1041.92 18 14.91 1733 465 2.73 / 421.90 2 3
5 13 455.56 18 14.99 944 255 2.98 / 422.16 2 3
6 8 0.36 170 15.04 293 749 3.73 / 422.91 2 3
7 14 0.36 40 15.01 292 175 3.91 / 423.08 2 3
Average= 3.85
(KJ/cycle)

Cycle 108 GMT 3/ 4/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 15.00 467 224 0.22 / 415.56 2 3
2 7 2003.64 31 14.89 2964 1368 1.59 / 416.93 2 3
3 13 1619.00 18 14.86 2502 669 2.26 / 417.60 2 3
4 13 1187.44 18 14.87 1941 520 2.78 / 418.12 2 3
5 13 588.68 18 14.95 1123 302 3.08 / 418.42 2 3
6 8 0.08 170 15.04 295 754 3.84 / 419.18 2 2
Average= 3.85
(KJ/cycle)

Cycle 107 GMT 24/ 3/2023 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 14.98 469 225 0.22 / 411.77 2 3
2 7 2012.56 31 14.89 2990 1380 1.60 / 413.15 2 3
3 13 1609.00 18 14.88 2492 667 2.27 / 413.82 2 3
4 13 1179.04 18 14.89 1940 520 2.79 / 414.34 2 3
5 13 447.40 18 15.00 920 248 3.04 / 414.58 2 3
6 8 0.52 170 15.05 295 755 3.80 / 415.34 2 3
Average= 3.85
(KJ/cycle)

Cycle 106 GMT 14/ 3/2023 16:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 32 14.99 462 222 0.22 / 407.89 2 3
2 7 2003.60 32 14.91 2983 1423 1.64 / 409.31 2 3
3 13 1594.36 18 14.88 2477 663 2.31 / 409.98 2 3
4 13 1163.84 18 14.91 1904 511 2.82 / 410.49 2 3
5 13 562.32 18 14.98 1089 294 3.11 / 410.78 2 4
6 8 0.12 170 15.05 298 762 3.88 / 411.54 2 3
Average= 3.85
(KJ/cycle)

Cycle 105 GMT 4/ 3/2023 19: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 14.99 474 227 0.23 / 404.14 2 3
2 7 2007.44 31 14.90 2979 1376 1.60 / 405.52 2 3
3 13 1607.04 18 14.89 2476 664 2.27 / 406.18 2 3
4 13 1054.28 18 14.91 1750 470 2.74 / 406.65 2 3
5 13 476.00 18 14.99 959 259 3.00 / 406.91 2 3
6 8 -0.04 170 15.05 297 760 3.76 / 407.67 2 3
Average= 3.85
(KJ/cycle)

Cycle 104 GMT 22/ 2/2023 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 32 15.00 459 220 0.22 / 400.39 2 3
2 7 2005.28 32 14.89 2961 1411 1.63 / 401.80 2 3
3 13 1601.76 18 14.88 2493 668 2.30 / 402.47 2 4
4 13 1055.04 18 14.91 1754 471 2.77 / 402.94 2 3
5 13 358.44 18 15.01 810 219 2.99 / 403.16 2 3
6 8 0.16 170 15.05 295 755 3.74 / 403.91 2 3
Average= 3.85
(KJ/cycle)

Cycle 103 GMT 12/ 2/2023 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 14.99 460 221 0.22 / 396.60 2 3
2 7 2005.76 31 14.91 2982 1378 1.60 / 397.98 2 2
3 13 1619.56 18 14.88 2505 671 2.27 / 398.65 2 2
4 13 1191.24 18 14.89 1939 520 2.79 / 399.17 2 3
5 13 464.44 18 15.00 951 257 3.05 / 399.42 2 3
6 8 0.00 170 15.05 291 745 3.79 / 400.17 2 3
Average= 3.85
(KJ/cycle)

Cycle 102 GMT 3/ 2/2023 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 14.98 475 228 0.23 / 392.77 2 3
2 7 2013.36 32 14.91 2973 1418 1.65 / 394.19 2 4
3 13 1613.16 18 14.88 2501 670 2.32 / 394.86 2 3
4 13 1180.04 18 14.90 1926 517 2.83 / 395.38 2 3
5 13 451.60 18 15.01 923 249 3.08 / 395.63 2 3
6 8 0.16 170 15.06 293 750 3.83 / 396.38 2 2
Average= 3.85
(KJ/cycle)

Cycle 101 GMT 24/ 1/2023 4: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 14.99 464 223 0.22 / 388.98 2 3
2 7 2014.52 31 14.91 2974 1375 1.60 / 390.35 2 2
3 13 1608.96 18 14.89 2483 665 2.26 / 391.02 2 3
4 13 1174.24 18 14.90 1929 517 2.78 / 391.53 2 3
5 13 448.28 18 15.00 936 253 3.03 / 391.79 2 3
6 8 -0.08 170 15.05 297 760 3.79 / 392.55 2 3
Average= 3.85
(KJ/cycle)

Cycle 100 GMT 14/ 1/2023 6:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 32 14.99 466 224 0.22 / 385.03 2 3
2 7 2006.32 31 14.91 2974 1375 1.60 / 386.41 2 3
3 13 1607.56 18 14.89 2492 668 2.27 / 387.08 2 3
4 13 1053.76 18 14.93 1762 474 2.74 / 387.55 2 3
5 13 475.48 18 15.01 974 263 3.00 / 387.81 2 3
6 8 0.04 170 15.05 298 762 3.77 / 388.57 2 3
7 14 0.04 40 15.03 298 179 3.94 / 388.75 2 2
Average= 3.85
(KJ/cycle)

Cycle 99 GMT 4/ 1/2023 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 32 14.99 463 222 0.22 / 381.09 2 3
2 7 2012.52 31 14.88 2975 1372 1.59 / 382.46 2 3
3 13 1608.64 18 14.87 2483 665 2.26 / 383.13 2 3
4 13 1171.16 18 14.88 1921 515 2.77 / 383.64 2 3
5 13 429.52 18 15.00 900 243 3.02 / 383.89 2 3
6 8 0.20 170 15.05 294 752 3.77 / 384.64 2 2
7 14 0.20 40 15.02 285 171 3.94 / 384.81 2 3
Average= 3.85
(KJ/cycle)

Cycle 98 GMT 25/12/2022 10:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 32 14.99 499 239 0.24 / 377.32 2 3
2 7 2003.28 32 14.89 2965 1413 1.65 / 378.73 2 3
3 13 1601.68 18 14.88 2470 662 2.31 / 379.39 2 3
4 13 1052.44 18 14.90 1751 470 2.78 / 379.86 2 3
5 13 483.40 18 14.99 981 265 3.05 / 380.12 2 4
6 8 -0.04 170 15.05 291 745 3.79 / 380.87 2 2
Average= 3.85
(KJ/cycle)

Cycle 97 GMT 15/12/2022 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 31 15.00 469 218 0.22 / 373.43 2 3
2 7 2011.32 31 14.90 2978 1376 1.59 / 374.80 2 3
3 13 1732.24 18 14.87 2644 708 2.30 / 375.51 2 4
4 13 1154.80 18 14.90 1882 505 2.81 / 376.01 2 3
5 13 568.12 18 14.98 1095 295 3.10 / 376.31 2 3
6 8 0.28 170 15.05 300 768 3.87 / 377.08 2 3
Average= 3.85
(KJ/cycle)

Cycle 96 GMT 5/12/2022 15:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 31 14.99 463 215 0.22 / 369.58 2 3
2 7 2012.00 31 14.91 2983 1379 1.59 / 370.95 2 3
3 13 1614.08 18 14.87 2517 674 2.27 / 371.63 2 3
4 13 1187.60 18 14.89 1936 519 2.79 / 372.15 2 3
5 13 593.84 18 14.98 1133 306 3.09 / 372.45 2 3
6 8 0.36 170 15.06 295 755 3.85 / 373.21 2 2
Average= 3.85
(KJ/cycle)

Cycle 95 GMT 25/11/2022 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.00 472 219 0.22 / 365.73 2 3
2 7 2011.08 31 14.91 2985 1380 1.60 / 367.11 2 3
3 13 1614.68 18 14.89 2499 670 2.27 / 367.78 2 3
4 13 1186.32 18 14.89 1933 518 2.79 / 368.30 2 3
5 13 584.32 18 14.98 1109 299 3.09 / 368.60 2 3
6 8 -0.24 170 15.05 298 762 3.85 / 369.36 2 3
Average= 3.85
(KJ/cycle)

Cycle 94 GMT 15/11/2022 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 14.99 460 214 0.21 / 361.69 2 3
2 7 2010.28 31 14.90 2989 1381 1.59 / 363.07 2 3
3 13 1614.08 18 14.88 2501 670 2.26 / 363.74 2 3
4 13 1183.16 18 14.90 1953 524 2.79 / 364.27 2 3
5 13 588.36 18 14.98 1121 302 3.09 / 364.57 2 3
6 8 0.12 170 15.06 300 768 3.86 / 365.34 2 4
7 14 0.12 40 15.03 294 177 4.04 / 365.51 2 4
Average= 3.85
(KJ/cycle)

Cycle 93 GMT 5/11/2022 22: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 31 15.01 464 216 0.22 / 357.76 2 3
2 7 2003.72 31 14.91 2977 1376 1.59 / 359.13 2 3
3 13 1615.84 18 14.88 2511 673 2.26 / 359.81 2 3
4 13 1185.08 18 14.90 1950 523 2.79 / 360.33 2 3
5 13 582.76 18 14.98 1113 300 3.09 / 360.63 2 3
6 13 22.88 18 15.08 337 91 3.18 / 360.72 2 2
7 8 0.40 170 15.05 296 757 3.94 / 361.48 2 3
Average= 3.85
(KJ/cycle)

Cycle 92 GMT 27/10/2022 0:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 31 15.02 476 222 0.22 / 354.00 2 3
2 7 2004.48 31 14.91 2965 1370 1.59 / 355.37 2 3
3 13 1603.28 18 14.89 2474 663 2.26 / 356.04 2 3
4 13 1052.96 18 14.92 1764 474 2.73 / 356.51 2 3
5 13 478.12 18 15.00 974 263 2.99 / 356.77 2 3
6 8 0.16 170 15.07 299 766 3.76 / 357.54 2 3
Average= 3.84
(KJ/cycle)

Cycle 91 GMT 17/10/2022 2:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 31 15.02 465 217 0.22 / 350.22 2 3
2 7 2013.44 31 14.92 2991 1383 1.60 / 351.61 2 3
3 13 1605.72 18 14.91 2492 669 2.27 / 352.27 2 3
4 13 1047.64 18 14.94 1743 469 2.74 / 352.74 2 3
5 13 474.52 18 15.02 963 260 3.00 / 353.00 2 3
6 8 0.16 170 15.09 304 780 3.78 / 353.78 3 3
Average= 3.85
(KJ/cycle)

Cycle 90 GMT 7/10/2022 4:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 31 15.03 480 224 0.22 / 346.25 2 3
2 7 2012.76 31 14.91 2993 1383 1.61 / 347.63 2 4
3 13 1607.28 18 14.90 2499 670 2.28 / 348.30 2 3
4 13 1168.20 18 14.90 1919 515 2.79 / 348.82 2 3
5 13 432.12 18 15.03 915 248 3.04 / 349.06 2 3
6 8 0.04 170 15.09 296 759 3.80 / 349.82 2 3
7 14 0.04 40 15.05 303 182 3.98 / 350.01 2 5
Average= 3.85
(KJ/cycle)

Cycle 89 GMT 27/ 9/2022 6:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.03 473 220 0.22 / 342.46 2 3
2 7 2002.84 31 14.92 2974 1376 1.60 / 343.83 2 3
3 13 1610.88 18 14.91 2495 670 2.27 / 344.50 2 4
4 13 1176.72 18 14.92 1920 516 2.78 / 345.02 2 3
5 13 448.72 18 15.02 924 250 3.03 / 345.27 2 3
6 8 0.24 170 15.09 295 757 3.79 / 346.02 2 3
Average= 3.84
(KJ/cycle)

Cycle 88 GMT 17/ 9/2022 9:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 31 15.03 465 217 0.22 / 338.56 2 3
2 7 2012.00 31 14.92 2990 1383 1.60 / 339.95 2 3
3 13 1737.00 18 14.88 2673 716 2.32 / 340.66 2 3
4 13 1147.80 18 14.92 1879 505 2.82 / 341.17 2 3
5 13 558.44 18 15.01 1077 291 3.11 / 341.46 2 3
6 8 0.16 170 15.09 303 777 3.89 / 342.24 2 3
Average= 3.85
(KJ/cycle)

Cycle 87 GMT 7/ 9/2022 11:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 31 15.02 473 220 0.22 / 334.82 2 3
2 7 2007.96 31 14.91 2985 1380 1.60 / 336.20 2 3
3 13 1601.72 18 14.89 2472 663 2.26 / 336.86 2 3
4 13 1042.96 18 14.93 1756 472 2.73 / 337.34 2 2
5 13 465.80 18 15.02 960 260 2.99 / 337.60 2 3
6 8 0.08 170 15.09 293 752 3.75 / 338.35 2 3
Average= 3.84
(KJ/cycle)

Cycle 86 GMT 28/ 8/2022 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 31 15.02 470 219 0.22 / 331.06 2 3
2 7 2011.88 31 14.91 2979 1377 1.60 / 332.44 2 3
3 13 1607.20 18 14.90 2500 670 2.27 / 333.11 2 3
4 13 1046.36 18 14.93 1767 475 2.74 / 333.58 2 3
5 13 470.56 18 15.03 972 263 3.00 / 333.85 2 4
6 8 0.20 170 15.09 295 757 3.76 / 334.60 2 2
Average= 3.85
(KJ/cycle)

Cycle 85 GMT 18/ 8/2022 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 15.02 477 222 0.22 / 327.09 2 3
2 7 2003.56 31 14.91 2969 1372 1.59 / 328.46 2 3
3 13 1596.68 18 14.90 2481 665 2.26 / 329.13 2 3
4 13 1160.12 18 14.92 1900 510 2.77 / 329.64 2 3
5 13 428.32 18 15.04 916 248 3.02 / 329.88 2 4
6 8 -0.24 170 15.09 302 775 3.79 / 330.66 2 3
7 14 -0.24 40 15.05 303 182 3.98 / 330.84 2 3
Average= 3.85
(KJ/cycle)

Cycle 84 GMT 8/ 8/2022 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 31 15.03 480 224 0.22 / 323.28 2 3
2 7 2010.88 31 14.92 2981 1379 1.60 / 324.66 2 3
3 13 1614.92 18 14.90 2514 674 2.28 / 325.34 2 4
4 13 1181.00 18 14.93 1926 518 2.79 / 325.85 2 3
5 13 451.08 18 15.03 930 252 3.05 / 326.10 2 3
6 8 0.20 170 15.09 297 762 3.81 / 326.87 2 3
Average= 3.85
(KJ/cycle)

Cycle 83 GMT 29/ 7/2022 20:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 31 15.02 496 231 0.23 / 319.46 2 3
2 7 2004.88 32 14.91 2982 1423 1.65 / 320.88 2 3
3 13 1602.44 18 14.90 2490 668 2.32 / 321.55 2 3
4 13 1049.52 18 14.93 1765 474 2.80 / 322.02 2 3
5 13 477.40 18 15.02 969 262 3.06 / 322.28 2 3
6 8 -0.20 170 15.09 302 775 3.83 / 323.06 2 3
Average= 3.85
(KJ/cycle)

Cycle 82 GMT 19/ 7/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 15.03 479 223 0.22 / 315.67 2 3
2 7 2013.56 31 14.92 2983 1380 1.60 / 317.05 2 3
3 13 1618.92 18 14.89 2493 668 2.27 / 317.72 2 4
4 13 1060.04 18 14.93 1768 475 2.75 / 318.20 2 2
5 13 480.08 18 15.03 975 264 3.01 / 318.46 2 3
6 8 0.36 170 15.09 299 767 3.78 / 319.23 2 3
Average= 3.85
(KJ/cycle)

Cycle 81 GMT 10/ 7/2022 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 15.05 461 215 0.22 / 311.72 2 3
2 7 2003.12 32 14.92 2969 1418 1.63 / 313.14 2 4
3 13 1605.40 18 14.90 2495 669 2.30 / 313.81 2 4
4 13 1048.28 18 14.95 1757 473 2.77 / 314.28 2 3
5 13 346.72 18 15.07 797 216 2.99 / 314.50 2 3
6 8 -0.32 170 15.11 300 771 3.76 / 315.27 2 3
7 14 -0.32 40 15.08 303 183 3.94 / 315.45 2 3
Average= 3.85
(KJ/cycle)

Cycle 80 GMT 30/ 6/2022 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.04 472 220 0.22 / 307.95 2 3
2 7 2011.88 31 14.94 2995 1387 1.61 / 309.34 2 3
3 13 1610.84 18 14.92 2505 673 2.28 / 310.01 2 3
4 13 1062.76 18 14.95 1780 479 2.76 / 310.49 2 3
5 13 479.36 18 15.04 981 266 3.02 / 310.76 2 3
6 8 0.56 170 15.10 292 750 3.77 / 311.50 2 4
Average= 3.85
(KJ/cycle)

Cycle 79 GMT 20/ 6/2022 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 15.05 480 224 0.22 / 303.96 2 3
2 7 2009.00 31 14.93 2984 1381 1.61 / 305.34 2 3
3 13 1606.68 18 14.92 2481 666 2.27 / 306.00 2 3
4 13 1164.40 18 14.94 1903 512 2.78 / 306.51 2 3
5 13 560.80 18 15.03 1078 292 3.07 / 306.81 2 3
6 8 -0.24 170 15.11 291 747 3.82 / 307.55 2 2
7 14 -0.24 40 15.08 293 177 4.00 / 307.73 2 3
Average= 3.85
(KJ/cycle)

Cycle 78 GMT 10/ 6/2022 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 31 15.05 476 222 0.22 / 300.17 2 3
2 7 2013.16 31 14.92 3000 1388 1.61 / 301.56 2 3
3 13 1604.48 18 14.91 2501 671 2.28 / 302.23 2 3
4 13 1048.32 18 14.96 1757 473 2.75 / 302.71 2 3
5 13 471.76 18 15.04 973 263 3.02 / 302.97 2 3
6 8 0.32 170 15.11 297 763 3.78 / 303.73 2 3
Average= 3.84
(KJ/cycle)

Cycle 77 GMT 31/ 5/2022 9:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 31 15.05 477 223 0.22 / 296.36 2 3
2 7 2011.68 31 14.92 2991 1383 1.61 / 297.74 2 3
3 13 1612.28 18 14.90 2498 670 2.28 / 298.41 2 3
4 13 1175.12 18 14.93 1926 518 2.79 / 298.93 2 3
5 13 439.88 18 15.06 927 251 3.04 / 299.18 2 3
6 8 -0.08 170 15.11 299 768 3.81 / 299.95 2 3
Average= 3.85
(KJ/cycle)

Cycle 76 GMT 21/ 5/2022 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 31 15.06 468 218 0.22 / 292.63 2 3
2 7 2011.00 31 14.93 3002 1389 1.61 / 294.02 2 3
3 13 1601.44 18 14.92 2492 669 2.28 / 294.69 2 5
4 13 1049.48 18 14.94 1768 475 2.75 / 295.17 2 3
5 13 360.28 18 15.07 811 220 2.97 / 295.39 2 3
6 8 0.36 170 15.12 293 753 3.73 / 296.14 2 2
Average= 3.85
(KJ/cycle)

Cycle 75 GMT 11/ 5/2022 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 31 15.06 460 215 0.21 / 288.75 2 3
2 7 2009.72 31 14.93 2998 1388 1.60 / 290.14 2 3
3 13 1728.08 18 14.90 2660 713 2.32 / 290.85 2 3
4 13 1131.52 18 14.95 1874 504 2.82 / 291.36 2 2
5 13 534.20 18 15.04 1056 286 3.11 / 291.64 2 3
6 8 0.36 170 15.12 299 769 3.87 / 292.41 2 2
Average= 3.85
(KJ/cycle)

Cycle 74 GMT 1/ 5/2022 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 31 15.08 487 228 0.23 / 284.73 2 3
2 7 2010.28 32 14.93 2990 1429 1.66 / 286.15 2 3
3 13 1607.40 18 14.92 2487 668 2.32 / 286.82 2 3
4 13 1170.48 18 14.94 1922 517 2.84 / 287.34 2 3
5 13 429.68 18 15.06 915 248 3.09 / 287.59 2 3
6 8 -0.28 170 15.12 300 771 3.86 / 288.36 2 3
7 14 -0.28 40 15.09 298 180 4.04 / 288.54 2 3
Average= 3.85
(KJ/cycle)

Cycle 73 GMT 21/ 4/2022 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 31 15.07 471 220 0.22 / 280.88 2 3
2 7 2012.72 31 14.94 2983 1382 1.60 / 282.26 2 3
3 13 1602.84 18 14.93 2503 673 2.27 / 282.94 2 3
4 13 1164.00 18 14.95 1901 512 2.79 / 283.45 2 3
5 13 443.96 18 15.07 932 253 3.04 / 283.70 2 3
6 8 0.28 170 15.13 310 797 3.84 / 284.50 2 3
Average= 3.84
(KJ/cycle)

Cycle 72 GMT 11/ 4/2022 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 31 15.07 474 221 0.22 / 277.09 2 3
2 7 2003.88 31 14.95 2977 1380 1.60 / 278.47 2 3
3 13 1609.40 18 14.93 2503 673 2.27 / 279.14 2 4
4 13 1061.72 18 14.97 1786 481 2.76 / 279.62 2 3
5 13 493.00 18 15.07 998 271 3.03 / 279.89 2 3
6 8 0.04 170 15.13 299 769 3.79 / 280.66 2 3
Average= 3.84
(KJ/cycle)

Cycle 71 GMT 1/ 4/2022 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 15.10 479 224 0.22 / 273.15 2 3
2 7 2002.92 31 14.95 2966 1375 1.60 / 274.52 2 3
3 13 1606.04 18 14.94 2483 668 2.27 / 275.19 2 3
4 13 1043.60 18 14.99 1744 471 2.74 / 275.66 2 3
5 13 466.40 18 15.08 960 261 3.00 / 275.92 2 3
6 8 0.32 170 15.14 297 764 3.76 / 276.68 2 3
7 14 0.32 40 15.11 303 183 3.95 / 276.87 2 3
Average= 3.85
(KJ/cycle)

Cycle 70 GMT 23/ 3/2022 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 14.99 470 218 0.22 / 269.11 2 3
2 7 2012.44 31 14.96 2994 1388 1.61 / 270.50 2 3
3 13 1735.32 18 14.93 2666 716 2.32 / 271.21 2 3
4 13 1138.60 18 14.97 1892 510 2.83 / 271.72 2 3
5 13 419.44 18 15.10 902 245 3.08 / 271.97 2 3
6 8 0.04 170 15.15 300 773 3.85 / 272.74 2 3
7 14 0.04 40 15.12 299 181 4.03 / 272.92 3 3
Average= 3.84
(KJ/cycle)

Cycle 69 GMT 13/ 3/2022 3:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 31 15.08 466 218 0.22 / 262.36 2 3
2 7 2012.76 31 14.95 2983 1382 1.60 / 263.74 2 3
3 13 1784.72 18 14.91 2716 729 2.33 / 264.47 2 3
4 13 1715.60 18 14.86 2627 703 3.03 / 265.17 2 3
5 13 1654.88 18 14.80 2553 680 3.71 / 265.85 2 6
6 13 1362.16 18 14.82 2169 579 4.29 / 266.43 2 3
7 13 1254.00 18 14.80 2022 539 4.83 / 266.97 2 3
8 13 1148.32 18 14.78 1892 503 5.33 / 267.47 2 4
9 13 1021.12 18 14.80 1721 458 5.79 / 267.93 2 4
10 8 0.24 170 15.04 303 775 6.57 / 268.71 2 3
11 14 0.24 40 15.01 305 183 6.75 / 268.89 3 3
Average= 3.84
(KJ/cycle)

Cycle 68 GMT 3/ 3/2022 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 31 15.10 465 218 0.22 / 258.60 2 3
2 7 2012.64 31 14.94 2975 1378 1.60 / 259.98 2 3
3 13 1609.36 18 14.92 2484 667 2.26 / 260.64 2 3
4 13 1048.84 18 14.97 1759 474 2.74 / 261.12 2 3
5 13 466.56 18 15.07 957 260 3.00 / 261.38 2 3
6 8 0.08 170 15.13 297 764 3.76 / 262.14 2 3
Average= 3.80
(KJ/cycle)

Cycle 67 GMT 21/ 2/2022 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 31 15.10 478 224 0.22 / 254.84 2 3
2 7 2004.16 31 14.95 2980 1381 1.60 / 256.22 2 3
3 13 1601.84 18 14.94 2474 665 2.27 / 256.88 2 3
4 13 1049.04 18 14.99 1754 473 2.74 / 257.35 2 3
5 13 469.32 18 15.09 955 259 3.00 / 257.61 2 4
6 8 0.04 170 15.15 298 767 3.77 / 258.38 2 3
Average= 3.80
(KJ/cycle)

Cycle 66 GMT 11/ 2/2022 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 31 15.09 493 231 0.23 / 251.03 2 2
2 7 2012.60 31 14.95 2984 1383 1.61 / 252.42 2 3
3 13 1607.52 18 14.94 2477 666 2.28 / 253.08 2 3
4 13 1170.28 18 14.97 1913 515 2.80 / 253.60 2 3
5 13 429.84 18 15.11 904 246 3.04 / 253.84 2 3
6 8 0.12 170 15.16 298 768 3.81 / 254.61 2 3
Average= 3.80
(KJ/cycle)

Cycle 65 GMT 1/ 2/2022 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 31 15.11 480 225 0.22 / 247.11 2 3
2 7 2012.60 31 14.97 2990 1388 1.61 / 248.50 2 3
3 13 1735.72 18 14.94 2665 717 2.33 / 249.22 2 3
4 13 1156.92 18 14.97 1912 515 2.84 / 249.73 2 3
5 13 561.96 18 15.08 1094 297 3.14 / 250.03 2 3
6 8 0.00 170 15.17 299 771 3.91 / 250.80 2 2
Average= 3.80
(KJ/cycle)

Cycle 64 GMT 22/ 1/2022 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 31 15.10 470 220 0.22 / 243.27 2 3
2 7 2013.04 31 14.97 2983 1384 1.60 / 244.65 2 3
3 13 1734.88 18 14.95 2636 709 2.31 / 245.36 2 3
4 13 1144.28 18 14.99 1885 509 2.82 / 245.87 2 3
5 13 438.08 18 15.11 921 250 3.07 / 246.12 2 3
6 8 0.00 170 15.17 299 771 3.84 / 246.89 2 3
Average= 3.80
(KJ/cycle)

Cycle 63 GMT 12/ 1/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 31 15.10 488 228 0.23 / 239.43 2 3
2 7 2014.72 31 14.96 2987 1385 1.61 / 240.82 2 3
3 13 1621.20 18 14.94 2515 676 2.29 / 241.49 2 5
4 13 1191.08 18 14.96 1947 524 2.81 / 242.02 2 3
5 13 461.44 18 15.11 955 260 3.07 / 242.28 2 3
6 8 0.32 170 15.16 298 768 3.84 / 243.05 2 3
Average= 3.80
(KJ/cycle)

Cycle 62 GMT 2/ 1/2022 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 31 15.10 485 227 0.23 / 235.33 2 3
2 7 2010.12 31 14.97 2985 1385 1.61 / 236.71 2 3
3 13 1732.12 18 14.94 2660 715 2.33 / 237.43 2 3
4 13 1137.44 18 14.98 1874 505 2.83 / 237.93 2 3
5 13 546.44 18 15.08 1078 293 3.13 / 238.23 2 3
6 8 0.48 170 15.17 307 792 3.92 / 239.02 2 6
7 14 0.48 40 15.15 308 187 4.10 / 239.20 2 4
Average= 3.80
(KJ/cycle)

Cycle 61 GMT 23/12/2021 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.11 483 226 0.23 / 231.36 2 3
2 7 2010.64 31 14.95 2976 1379 1.61 / 232.74 2 3
3 13 1598.36 18 14.94 2479 667 2.27 / 233.40 2 4
4 13 1044.20 18 14.99 1746 471 2.74 / 233.87 2 3
5 13 472.32 18 15.10 964 262 3.01 / 234.14 2 3
6 8 0.48 170 15.17 303 781 3.79 / 234.92 2 3
7 14 0.48 40 15.14 302 183 3.97 / 235.10 2 3
Average= 3.79
(KJ/cycle)

Cycle 60 GMT 13/12/2021 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 31 15.13 467 219 0.22 / 227.33 3 3
2 7 2004.96 31 14.97 2979 1382 1.60 / 228.71 2 3
3 13 1613.28 18 14.95 2506 674 2.28 / 229.39 2 3
4 13 1174.68 18 14.97 1934 521 2.80 / 229.91 2 3
5 13 439.88 18 15.11 931 253 3.05 / 230.16 2 3
6 8 -0.08 170 15.18 304 785 3.83 / 230.94 2 3
7 14 -0.08 40 15.15 307 186 4.02 / 231.13 3 3
Average= 3.79
(KJ/cycle)

Cycle 59 GMT 4/12/2021 1:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 31 15.14 476 223 0.22 / 223.60 2 3
2 7 2002.96 31 14.98 2973 1381 1.60 / 224.98 2 3
3 13 1596.40 18 14.97 2472 666 2.27 / 225.65 2 3
4 13 1040.72 18 15.02 1744 472 2.74 / 226.12 2 3
5 13 332.28 18 15.17 770 210 2.95 / 226.33 2 3
6 8 0.12 170 15.20 302 780 3.73 / 227.11 2 3
Average= 3.79
(KJ/cycle)

Cycle 58 GMT 24/11/2021 4: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 15.14 463 217 0.22 / 219.61 2 3
2 7 2007.44 31 14.98 2980 1384 1.60 / 221.00 2 3
3 13 1598.80 18 14.98 2472 667 2.27 / 221.66 2 3
4 13 1044.80 18 15.03 1742 471 2.74 / 222.14 2 2
5 13 461.12 18 15.14 961 262 3.00 / 222.40 2 3
6 8 0.16 170 15.20 307 793 3.79 / 223.19 2 3
7 14 0.16 40 15.17 308 187 3.98 / 223.38 2 3
Average= 3.79
(KJ/cycle)

Cycle 57 GMT 14/11/2021 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 31 15.15 483 227 0.23 / 215.53 2 3
2 7 2009.72 31 14.97 2975 1381 1.61 / 216.91 2 3
3 13 1600.20 18 14.97 2478 668 2.28 / 217.58 2 3
4 13 1164.92 18 15.00 1917 518 2.79 / 218.09 2 3
5 13 421.00 18 15.15 890 243 3.04 / 218.34 2 3
6 13 20.80 18 15.23 336 92 3.13 / 218.43 2 2
7 8 0.12 170 15.20 303 783 3.91 / 219.21 2 3
8 14 0.12 40 15.17 306 186 4.10 / 219.40 2 3
Average= 3.78
(KJ/cycle)

Cycle 56 GMT 4/11/2021 8: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 15.17 455 214 0.21 / 211.54 2 3
2 7 2011.28 31 14.98 2983 1385 1.60 / 212.92 2 3
3 13 1597.84 18 14.97 2468 665 2.26 / 213.59 2 3
4 13 1157.20 18 15.01 1898 513 2.78 / 214.10 2 3
5 13 403.92 18 15.16 880 240 3.02 / 214.34 2 3
6 8 0.16 170 15.21 301 778 3.80 / 215.12 2 3
7 14 0.16 40 15.18 299 182 3.98 / 215.30 3 4
Average= 3.78
(KJ/cycle)

Cycle 55 GMT 25/10/2021 10:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 31 15.17 477 224 0.22 / 207.61 2 3
2 7 2011.40 31 14.98 2986 1387 1.61 / 208.99 2 3
3 13 1604.52 18 14.98 2482 669 2.28 / 209.66 2 3
4 13 1044.68 18 15.03 1758 476 2.76 / 210.14 2 3
5 13 348.48 18 15.17 800 218 2.97 / 210.36 2 3
6 8 0.00 170 15.22 302 781 3.76 / 211.14 2 3
7 14 0.00 40 15.19 306 186 3.94 / 211.32 2 3
Average= 3.77
(KJ/cycle)

Cycle 54 GMT 15/10/2021 12:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 31 15.17 487 229 0.23 / 203.85 2 3
2 7 2008.24 31 14.99 2980 1385 1.61 / 205.23 2 3
3 13 1601.28 18 14.98 2487 671 2.28 / 205.90 2 3
4 13 1041.32 18 15.04 1760 476 2.76 / 206.38 2 3
5 13 337.44 18 15.19 785 215 2.98 / 206.59 2 3
6 8 0.20 170 15.22 305 789 3.76 / 207.38 2 3
Average= 3.77
(KJ/cycle)

Cycle 53 GMT 5/10/2021 14:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 15.17 500 228 0.23 / 200.04 2 3
2 7 2007.92 31 15.00 2989 1390 1.62 / 201.42 2 3
3 13 1605.56 18 14.97 2501 674 2.29 / 202.10 2 3
4 13 1046.96 18 15.04 1752 474 2.77 / 202.57 2 3
5 13 464.00 18 15.16 960 262 3.03 / 202.84 2 3
6 8 -0.08 170 15.23 302 782 3.81 / 203.62 2 3
Average= 3.77
(KJ/cycle)

Cycle 52 GMT 25/ 9/2021 16:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 15.17 484 220 0.22 / 196.29 2 3
2 7 2009.96 31 14.98 2982 1385 1.61 / 197.67 2 3
3 13 1594.48 18 14.98 2475 667 2.27 / 198.34 2 3
4 13 1029.92 18 15.05 1738 471 2.74 / 198.81 2 3
5 13 314.32 18 15.20 755 207 2.95 / 199.02 2 3
6 8 0.08 170 15.23 305 790 3.74 / 199.81 2 2
Average= 3.77
(KJ/cycle)

Cycle 51 GMT 15/ 9/2021 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 15.17 485 221 0.22 / 192.46 2 3
2 7 2006.16 31 14.99 2980 1385 1.61 / 193.84 2 3
3 13 1598.92 18 14.99 2481 669 2.27 / 194.51 2 3
4 13 1038.36 18 15.05 1744 472 2.75 / 194.99 2 3
5 13 331.92 18 15.18 792 216 2.96 / 195.20 2 3
6 8 0.24 190 15.23 299 865 3.83 / 196.07 2 3
Average= 3.77
(KJ/cycle)

Cycle 50 GMT 5/ 9/2021 20:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 30 15.17 469 213 0.21 / 188.34 2 3
2 7 2002.52 31 15.00 2970 1381 1.59 / 189.73 2 3
3 13 1723.12 18 14.97 2656 716 2.31 / 190.44 2 4
4 13 1137.36 18 15.03 1885 510 2.82 / 190.95 2 3
5 13 418.04 18 15.19 905 247 3.07 / 191.20 2 3
6 13 17.28 18 15.27 340 93 3.16 / 191.29 2 3
7 8 0.00 190 15.23 296 857 4.02 / 192.15 2 3
8 14 0.00 20 15.21 298 91 4.11 / 192.24 2 3
Average= 3.77
(KJ/cycle)

Cycle 49 GMT 26/ 8/2021 22:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 15.17 479 218 0.22 / 184.43 2 3
2 7 2005.16 31 15.00 2970 1381 1.60 / 185.82 2 3
3 13 1593.44 18 15.00 2478 669 2.27 / 186.48 2 3
4 13 1040.48 18 15.07 1742 473 2.74 / 186.96 2 3
5 13 332.84 18 15.22 770 211 2.95 / 187.17 2 2
6 8 -0.04 190 15.25 301 872 3.82 / 188.04 2 4
7 14 -0.04 20 15.22 299 91 3.91 / 188.13 2 4
Average= 3.76
(KJ/cycle)

Cycle 48 GMT 17/ 8/2021 0:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 30 15.19 504 230 0.23 / 180.52 2 3
2 7 2004.04 31 15.00 2976 1384 1.61 / 181.90 2 3
3 13 1725.56 18 14.98 2635 711 2.32 / 182.61 2 3
4 13 1124.16 18 15.05 1862 504 2.83 / 183.12 2 3
5 13 395.68 18 15.20 869 238 3.07 / 183.36 2 3
6 8 0.08 190 15.25 297 861 3.93 / 184.22 2 3
Average= 3.76
(KJ/cycle)

Cycle 47 GMT 7/ 8/2021 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 30 15.18 491 224 0.22 / 176.76 2 3
2 7 2005.20 31 15.00 2979 1385 1.61 / 178.15 2 3
3 13 1589.68 18 15.00 2471 667 2.28 / 178.81 2 3
4 13 1027.48 18 15.08 1709 464 2.74 / 179.28 2 3
5 13 325.32 18 15.22 757 207 2.95 / 179.49 2 2
6 8 0.40 175 15.26 301 804 3.75 / 180.29 2 2
Average= 3.76
(KJ/cycle)

Cycle 46 GMT 28/ 7/2021 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.19 496 226 0.23 / 172.81 2 3
2 7 2008.36 32 15.01 2981 1432 1.66 / 174.24 2 3
3 13 1586.72 18 15.00 2474 668 2.33 / 174.91 2 3
4 13 1025.00 18 15.08 1728 469 2.79 / 175.38 2 3
5 13 318.00 18 15.22 748 205 3.00 / 175.58 2 3
6 8 -0.08 175 15.26 297 793 3.79 / 176.38 2 3
7 14 -0.08 35 15.23 306 163 3.96 / 176.54 2 4
Average= 3.76
(KJ/cycle)

Cycle 45 GMT 18/ 7/2021 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 30 15.20 468 213 0.21 / 168.99 2 3
2 7 2003.12 31 15.01 2974 1384 1.60 / 170.37 2 3
3 13 1596.24 18 15.01 2486 672 2.27 / 171.04 2 3
4 13 1036.12 18 15.08 1756 477 2.75 / 171.52 2 3
5 13 445.32 18 15.20 942 258 3.00 / 171.78 2 3
6 8 0.24 175 15.26 302 806 3.81 / 172.58 2 3
Average= 3.75
(KJ/cycle)

Cycle 44 GMT 8/ 7/2021 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 30 15.20 498 227 0.23 / 165.20 2 3
2 7 2003.24 31 15.01 2973 1383 1.61 / 166.59 2 3
3 13 1594.44 18 15.00 2469 667 2.28 / 167.25 2 5
4 13 1031.04 18 15.08 1741 473 2.75 / 167.73 2 3
5 13 319.64 18 15.23 756 207 2.96 / 167.93 2 3
6 8 0.12 180 15.26 305 838 3.79 / 168.77 2 3
Average= 3.75
(KJ/cycle)

Cycle 43 GMT 28/ 6/2021 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 30 15.20 471 215 0.21 / 161.09 2 3
2 7 2004.16 31 15.01 2983 1388 1.60 / 162.47 2 4
3 13 1593.88 18 15.01 2499 675 2.28 / 163.15 2 3
4 13 1033.72 18 15.08 1761 478 2.76 / 163.63 2 3
5 13 458.04 18 15.20 971 266 3.02 / 163.89 2 3
6 13 25.12 18 15.29 355 98 3.12 / 163.99 2 2
7 8 -0.04 180 15.26 308 846 3.97 / 164.84 2 4
8 14 -0.04 30 15.23 308 141 4.11 / 164.98 2 3
Average= 3.75
(KJ/cycle)

Cycle 42 GMT 18/ 6/2021 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 30 15.22 483 221 0.22 / 157.12 2 3
2 7 2006.64 31 15.01 2977 1385 1.61 / 158.51 2 3
3 13 1601.20 18 15.00 2489 672 2.28 / 159.18 2 3
4 13 1035.32 18 15.08 1740 472 2.75 / 159.65 2 3
5 13 337.52 18 15.23 805 221 2.97 / 159.87 2 3
6 8 0.04 180 15.27 311 855 3.83 / 160.73 2 3
7 14 0.04 30 15.25 314 144 3.97 / 160.87 2 2
Average= 3.74
(KJ/cycle)

Cycle 41 GMT 8/ 6/2021 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 15.20 492 224 0.22 / 153.31 2 3
2 7 2005.96 31 15.00 2984 1388 1.61 / 154.70 2 3
3 13 1590.56 18 15.01 2475 669 2.28 / 155.36 2 5
4 13 1027.44 18 15.09 1732 470 2.75 / 155.84 2 3
5 13 438.72 18 15.20 941 257 3.01 / 156.09 2 3
6 8 0.12 170 15.27 312 810 3.82 / 156.90 2 3
Average= 3.74
(KJ/cycle)

Cycle 40 GMT 29/ 5/2021 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 30 15.20 491 224 0.22 / 149.26 2 3
2 7 2006.12 31 15.02 2984 1389 1.61 / 150.65 2 3
3 13 1595.44 18 15.01 2493 674 2.29 / 151.32 2 3
4 13 1032.68 18 15.08 1742 473 2.76 / 151.79 2 3
5 13 438.60 18 15.21 936 256 3.02 / 152.05 2 3
6 8 0.24 170 15.27 322 836 3.85 / 152.89 2 3
7 14 0.24 40 15.24 324 198 4.05 / 153.08 2 3
Average= 3.73
(KJ/cycle)

Cycle 39 GMT 19/ 5/2021 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 30 15.22 461 210 0.21 / 145.31 2 3
2 7 2005.96 31 15.01 2986 1389 1.60 / 146.69 2 3
3 13 1588.32 18 15.01 2472 668 2.27 / 147.36 2 4
4 13 1030.80 18 15.09 1745 474 2.74 / 147.84 2 3
5 13 443.24 18 15.20 943 258 3.00 / 148.09 2 3
6 13 57.56 18 15.28 418 115 3.11 / 148.21 2 3
7 8 0.08 170 15.26 318 825 3.94 / 149.03 2 4
Average= 3.73
(KJ/cycle)

Cycle 38 GMT 9/ 5/2021 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 30 15.22 479 219 0.22 / 141.47 2 3
2 7 2005.00 32 15.02 2987 1436 1.65 / 142.90 2 3
3 13 1593.08 18 15.03 2479 671 2.33 / 143.57 2 3
4 13 1035.12 18 15.10 1750 476 2.80 / 144.05 2 3
5 13 332.40 18 15.25 775 213 3.01 / 144.26 2 3
6 8 0.20 180 15.28 303 833 3.85 / 145.09 2 3
Average= 3.72
(KJ/cycle)

Cycle 37 GMT 29/ 4/2021 22:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 30 15.22 472 216 0.22 / 137.49 2 3
2 7 2004.32 32 15.01 2978 1430 1.65 / 138.92 2 3
3 13 1585.24 18 15.02 2469 668 2.31 / 139.59 2 3
4 13 1025.24 18 15.10 1736 472 2.79 / 140.06 2 3
5 13 448.60 18 15.21 944 258 3.04 / 140.32 2 3
6 8 -0.12 180 15.28 303 833 3.88 / 141.15 2 2
7 14 -0.12 20 15.25 313 95 3.97 / 141.25 2 3
Average= 3.72
(KJ/cycle)

Cycle 36 GMT 20/ 4/2021 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 15.22 474 216 0.22 / 133.65 2 3
2 7 2004.68 31 15.02 2970 1383 1.60 / 135.03 2 3
3 13 1588.40 18 15.03 2468 668 2.27 / 135.70 2 3
4 13 1027.08 18 15.11 1714 466 2.73 / 136.16 2 3
5 13 319.96 18 15.25 749 206 2.94 / 136.37 2 3
6 8 0.12 180 15.28 297 817 3.76 / 137.19 2 6
7 14 0.12 20 15.27 292 89 3.84 / 137.28 2 2
Average= 3.71
(KJ/cycle)

Cycle 35 GMT 10/ 4/2021 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 30 15.23 467 213 0.21 / 129.79 2 3
2 7 2002.84 31 15.02 2961 1379 1.59 / 131.17 2 3
3 13 1584.56 18 15.03 2472 669 2.26 / 131.84 2 3
4 13 1020.48 18 15.11 1718 467 2.73 / 132.31 2 2
5 13 310.00 18 15.26 752 207 2.93 / 132.51 2 3
6 8 0.36 180 15.28 300 825 3.76 / 133.34 2 3
7 14 0.36 20 15.27 298 91 3.85 / 133.43 2 3
Average= 3.71
(KJ/cycle)

Cycle 34 GMT 31/ 3/2021 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 15.23 490 224 0.22 / 125.86 2 3
2 7 2005.80 31 15.02 2979 1387 1.61 / 127.25 2 3
3 13 1590.88 18 15.02 2494 674 2.29 / 127.93 2 3
4 13 1029.56 18 15.10 1735 472 2.76 / 128.40 2 3
5 13 442.04 18 15.21 933 255 3.01 / 128.65 2 3
6 8 -0.04 180 15.28 304 836 3.85 / 129.49 2 3
7 14 -0.04 20 15.25 299 91 3.94 / 129.58 2 3
Average= 3.70
(KJ/cycle)

Cycle 33 GMT 21/ 3/2021 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 15.24 461 211 0.21 / 122.03 2 3
2 7 2006.24 31 15.03 2985 1391 1.60 / 123.42 2 4
3 13 1588.76 18 15.04 2481 672 2.27 / 124.09 2 3
4 13 1032.80 18 15.12 1738 473 2.75 / 124.56 2 3
5 13 446.64 18 15.24 924 253 3.00 / 124.81 2 3
6 8 0.28 180 15.29 300 826 3.83 / 125.64 2 3
Average= 3.70
(KJ/cycle)

Cycle 32 GMT 11/ 3/2021 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 30 15.23 477 218 0.22 / 118.13 2 3
2 7 2007.44 32 15.04 2974 1431 1.65 / 119.56 2 3
3 13 1598.28 18 15.05 2458 666 2.32 / 120.23 2 3
4 13 1158.32 18 15.09 1888 513 2.83 / 120.74 2 3
5 13 410.72 18 15.25 870 239 3.07 / 120.98 2 3
6 8 -0.04 180 15.30 303 834 3.90 / 121.81 2 3
Average= 3.69
(KJ/cycle)

Cycle 31 GMT 1/ 3/2021 10:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 30 15.23 484 221 0.22 / 114.33 2 3
2 7 2003.04 31 15.04 2968 1384 1.60 / 115.71 2 3
3 13 1591.52 18 15.04 2487 673 2.28 / 116.39 2 3
4 13 1025.20 18 15.12 1729 471 2.75 / 116.86 2 3
5 13 317.52 18 15.26 764 210 2.96 / 117.07 2 3
6 8 0.20 180 15.29 308 848 3.81 / 117.91 2 3
Average= 3.68
(KJ/cycle)

Cycle 30 GMT 19/ 2/2021 13: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.25 485 222 0.22 / 110.34 2 3
2 7 2006.44 31 15.03 2985 1391 1.61 / 111.73 2 3
3 13 1589.76 18 15.05 2458 666 2.28 / 112.40 2 3
4 13 1151.96 18 15.10 1897 516 2.79 / 112.92 2 3
5 13 404.68 18 15.25 883 242 3.04 / 113.16 2 3
6 8 0.04 180 15.30 310 854 3.89 / 114.01 2 3
7 14 0.04 20 15.28 314 96 3.99 / 114.11 2 4
Average= 3.68
(KJ/cycle)

Cycle 29 GMT 9/ 2/2021 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 15.27 483 221 0.22 / 106.35 2 3
2 3 1018.56 1 15.34 1748 27 0.25 / 106.37 2 3
3 7 2003.28 31 15.05 2969 1385 1.63 / 107.76 2 3
4 13 1588.32 18 15.06 2475 671 2.30 / 108.43 2 3
5 13 1026.48 18 15.14 1736 473 2.78 / 108.90 2 3
6 13 440.12 18 15.25 927 254 3.03 / 109.16 2 3
7 8 0.16 180 15.31 313 863 3.89 / 110.02 2 3
8 14 0.16 20 15.29 329 101 3.99 / 110.12 2 3
Average= 3.67
(KJ/cycle)

Cycle 28 GMT 30/ 1/2021 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 15.25 489 224 0.22 / 102.54 2 3
2 7 2005.80 31 15.06 2972 1388 1.61 / 103.93 2 3
3 13 1591.00 18 15.07 2464 668 2.28 / 104.60 2 3
4 13 1030.64 18 15.15 1727 471 2.75 / 105.07 2 3
5 13 317.40 18 15.29 744 205 2.96 / 105.27 2 3
6 8 0.08 180 15.32 310 855 3.81 / 106.13 2 3
Average= 3.66
(KJ/cycle)

Cycle 27 GMT 20/ 1/2021 19: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 30 15.27 485 222 0.22 / 98.65 2 3
2 7 2003.92 31 15.06 2972 1388 1.61 / 100.04 2 4
3 13 1597.36 18 15.07 2475 671 2.28 / 100.71 2 3
4 13 1037.76 18 15.15 1721 469 2.75 / 101.18 2 3
5 13 442.44 18 15.27 922 253 3.00 / 101.43 2 3
6 8 0.28 180 15.31 321 885 3.89 / 102.32 2 2
Average= 3.65
(KJ/cycle)

Cycle 26 GMT 10/ 1/2021 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 30 15.26 481 220 0.22 / 94.85 2 3
2 7 2003.96 31 15.07 2979 1392 1.61 / 96.24 2 3
3 13 1590.60 18 15.08 2459 667 2.28 / 96.91 2 3
4 13 1024.16 18 15.16 1716 468 2.75 / 97.38 2 3
5 13 310.44 18 15.29 738 203 2.95 / 97.58 2 3
6 8 -0.32 180 15.33 306 844 3.80 / 98.43 2 3
Average= 3.65
(KJ/cycle)

Cycle 25 GMT 31/12/2020 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 15.26 479 212 0.21 / 90.96 2 3
2 7 2004.16 31 15.07 2967 1386 1.60 / 92.35 2 3
3 13 1585.80 18 15.08 2465 669 2.27 / 93.02 2 3
4 13 1143.24 18 15.13 1892 515 2.78 / 93.53 2 3
5 13 398.32 18 15.27 871 239 3.02 / 93.77 2 3
6 8 0.24 180 15.32 312 860 3.88 / 94.63 2 3
Average= 3.64
(KJ/cycle)

Cycle 24 GMT 22/12/2020 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 15.27 440 195 0.19 / 87.06 2 3
2 7 2003.76 31 15.07 2961 1383 1.58 / 88.44 2 3
3 13 1583.96 18 15.08 2421 657 2.24 / 89.10 2 3
4 13 1020.84 18 15.15 1685 459 2.69 / 89.56 2 3
5 13 435.28 18 15.27 914 251 2.95 / 89.81 2 3
6 8 0.00 180 15.32 315 869 3.81 / 90.68 2 3
7 14 0.00 15 15.30 320 73 3.89 / 90.75 2 3
Average= 3.63
(KJ/cycle)

Cycle 23 GMT 12/12/2020 3:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 29 15.29 440 195 0.20 / 83.31 2 3
2 3 1017.20 1 15.36 1724 26 0.22 / 83.34 2 2
3 7 2003.64 32 15.06 2965 1429 1.65 / 84.77 2 3
4 13 1588.68 18 15.08 2421 657 2.31 / 85.42 2 3
5 13 1019.44 18 15.16 1678 458 2.77 / 85.88 2 3
6 13 429.80 18 15.28 868 239 3.00 / 86.12 2 3
7 8 0.16 180 15.33 269 742 3.75 / 86.86 2 3
Average= 3.62
(KJ/cycle)

Cycle 22 GMT 2/12/2020 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 29 15.28 443 196 0.20 / 79.61 2 3
2 7 2003.36 31 15.07 2966 1386 1.58 / 81.00 2 3
3 13 1587.36 18 15.08 2444 663 2.25 / 81.66 2 3
4 13 1016.76 18 15.16 1673 457 2.70 / 82.12 2 3
5 13 301.52 18 15.30 695 191 2.89 / 82.31 2 3
6 8 0.12 180 15.33 270 745 3.64 / 83.05 2 3
7 14 0.12 15 15.32 271 62 3.70 / 83.12 2 4
Average= 3.61
(KJ/cycle)

Cycle 21 GMT 22/11/2020 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.27 438 194 0.19 / 75.99 2 3
2 7 2003.68 31 15.07 2970 1387 1.58 / 77.38 2 3
3 13 1582.04 18 15.09 2425 659 2.24 / 78.04 2 3
4 13 1018.68 18 15.16 1679 458 2.70 / 78.49 2 3
5 13 305.68 18 15.31 705 194 2.89 / 78.69 2 3
6 8 0.28 175 15.34 271 727 3.62 / 79.42 2 3
Average= 3.61
(KJ/cycle)

Cycle 20 GMT 12/11/2020 9:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 15.29 442 203 0.20 / 72.38 2 3
2 3 968.96 -1 15.60 0 0 0.00 / 72.38 2 3
3 7 2004.32 31 15.07 2960 1383 1.59 / 73.76 2 3
4 13 1581.88 18 15.09 2426 659 2.24 / 74.42 2 3
5 13 1018.00 18 15.17 1678 458 2.70 / 74.88 2 3
6 13 303.84 18 15.31 696 192 2.89 / 75.07 2 3
7 8 -0.08 175 15.34 270 725 3.62 / 75.80 2 3
Average= 3.61
(KJ/cycle)

Cycle 19 GMT 2/11/2020 10:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 15.30 437 187 0.19 / 68.72 2 3
2 3 1024.08 1 15.35 1742 27 0.21 / 68.75 2 3
3 7 2005.36 31 15.08 2959 1383 1.60 / 70.13 2 6
4 13 1588.60 18 15.10 2435 662 2.26 / 70.79 2 2
5 13 1015.92 18 15.17 1674 457 2.72 / 71.25 2 3
6 13 290.16 18 15.32 685 189 2.91 / 71.44 2 3
7 8 0.12 175 15.34 274 736 3.64 / 72.18 2 3
Average= 3.61
(KJ/cycle)

Cycle 18 GMT 23/10/2020 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 26 15.28 437 174 0.17 / 64.99 2 3
2 10 1000.72 3 15.29 1686 77 0.25 / 65.07 2 3
3 7 2004.16 31 15.09 2960 1385 1.64 / 66.45 2 3
4 13 1589.40 18 15.09 2435 661 2.30 / 67.11 2 3
5 13 1021.40 18 15.17 1686 460 2.76 / 67.57 2 3
6 13 433.24 18 15.28 876 241 3.00 / 67.81 2 3
7 8 -0.12 175 15.35 269 723 3.72 / 68.54 2 4
Average= 3.61
(KJ/cycle)

Cycle 17 GMT 13/10/2020 14:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 15.28 432 191 0.19 / 61.35 2 3
2 7 2003.80 31 15.06 2967 1385 1.58 / 62.74 2 3
3 13 1583.60 18 15.08 2428 659 2.24 / 63.40 2 3
4 13 1007.76 18 15.16 1663 454 2.69 / 63.85 2 3
5 13 417.84 18 15.28 854 235 2.92 / 64.08 2 3
6 8 0.12 175 15.34 272 730 3.65 / 64.81 2 4
Average= 3.60
(KJ/cycle)

Cycle 16 GMT 12/10/2020 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 15.27 437 194 0.19 / 57.75 2 3
2 7 2003.16 31 15.06 2971 1387 1.58 / 59.14 2 3
3 13 1577.64 18 15.08 2419 657 2.24 / 59.79 2 3
4 13 1002.60 18 15.16 1655 452 2.69 / 60.25 2 3
5 13 286.68 18 15.31 679 187 2.88 / 60.43 2 3
6 8 0.12 175 15.33 271 727 3.60 / 61.16 2 3
Average= 3.60
(KJ/cycle)

Cycle 15 GMT 11/10/2020 13:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 29 15.28 440 195 0.19 / 54.06 2 3
2 7 2003.28 31 15.05 2967 1384 1.58 / 55.45 2 3
3 13 1580.84 18 15.07 2416 655 2.23 / 56.10 2 3
4 13 1004.48 18 15.16 1658 452 2.69 / 56.56 2 3
5 13 287.48 18 15.30 678 187 2.87 / 56.74 2 3
6 8 0.08 175 15.33 272 730 3.60 / 57.47 2 3
7 14 0.08 20 15.31 276 85 3.69 / 57.56 2 3
Average= 3.60
(KJ/cycle)

Cycle 14 GMT 10/10/2020 13:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 29 15.28 437 194 0.19 / 50.48 2 3
2 7 2002.36 31 15.05 2951 1377 1.57 / 51.86 2 3
3 13 1575.48 18 15.07 2410 654 2.22 / 52.51 2 3
4 13 996.04 18 15.16 1648 450 2.67 / 52.96 2 3
5 13 278.60 18 15.30 664 183 2.86 / 53.14 2 3
6 8 0.04 175 15.33 270 724 3.58 / 53.87 2 2
Average= 3.59
(KJ/cycle)

Cycle 13 GMT 9/10/2020 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 29 15.29 435 193 0.19 / 46.89 2 3
2 7 2002.52 31 15.05 2965 1383 1.58 / 48.27 2 3
3 13 1574.40 18 15.08 2415 656 2.23 / 48.93 2 3
4 13 997.32 18 15.17 1649 450 2.68 / 49.38 2 3
5 13 283.64 18 15.31 675 186 2.87 / 49.57 2 3
6 8 -0.04 175 15.34 269 722 3.59 / 50.29 2 3
Average= 3.59
(KJ/cycle)

Cycle 12 GMT 8/10/2020 12:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 29 15.28 440 195 0.19 / 43.30 2 3
2 7 2008.84 31 15.05 2962 1382 1.58 / 44.68 2 3
3 13 1581.68 18 15.07 2421 657 2.23 / 45.34 2 3
4 13 1001.04 18 15.16 1652 451 2.68 / 45.79 2 3
5 13 279.60 18 15.31 665 183 2.87 / 45.97 2 3
6 8 0.16 175 15.34 270 725 3.59 / 46.70 2 2
Average= 3.59
(KJ/cycle)

Cycle 11 GMT 7/10/2020 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 15.29 437 194 0.19 / 39.57 2 3
2 7 2006.44 31 15.07 2965 1385 1.58 / 40.95 2 3
3 13 1594.72 20 15.07 2441 736 2.31 / 41.69 2 3
4 13 1003.12 20 15.15 1654 501 2.82 / 42.19 2 4
5 13 249.72 20 15.31 625 191 3.01 / 42.38 2 3
6 8 0.00 175 15.34 270 725 3.73 / 43.11 2 3
Average= 3.59
(KJ/cycle)

Cycle 10 GMT 6/10/2020 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 15.28 445 197 0.20 / 35.86 2 3
2 7 2006.20 31 15.05 2968 1385 1.58 / 37.25 2 3
3 13 1579.40 20 15.07 2424 731 2.31 / 37.98 2 5
4 13 983.12 20 15.16 1628 494 2.81 / 38.47 2 3
5 13 220.76 20 15.32 586 180 2.99 / 38.65 2 3
6 8 0.08 175 15.33 269 722 3.71 / 39.37 2 3
Average= 3.58
(KJ/cycle)

Cycle 9 GMT 5/10/2020 11:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 15.28 446 198 0.20 / 32.20 2 3
2 7 2002.84 31 15.06 2963 1383 1.58 / 33.58 2 3
3 13 1575.72 20 15.08 2416 729 2.31 / 34.31 2 4
4 13 978.32 20 15.16 1618 491 2.80 / 34.80 2 3
5 13 112.56 20 15.35 447 137 2.94 / 34.94 2 3
6 8 0.24 175 15.34 271 727 3.66 / 35.67 2 3
Average= 3.57
(KJ/cycle)

Cycle 8 GMT 4/10/2020 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 29 15.29 427 189 0.19 / 28.46 2 3
2 7 2007.08 32 15.05 2967 1429 1.62 / 29.89 2 3
3 13 1571.24 20 15.08 2397 723 2.34 / 30.61 2 3
4 13 846.00 20 15.19 1445 439 2.78 / 31.05 2 3
5 13 125.36 20 15.35 461 142 2.92 / 31.19 2 3
6 8 0.12 175 15.34 269 722 3.64 / 31.92 2 2
7 14 0.12 20 15.33 275 84 3.73 / 32.00 2 2
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 3/10/2020 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 15.28 430 191 0.19 / 24.88 2 3
2 7 2003.12 32 15.06 2961 1427 1.62 / 26.31 2 3
3 13 1465.80 18 15.10 2275 618 2.24 / 26.93 2 3
4 13 916.88 18 15.18 1543 422 2.66 / 27.35 2 3
5 13 342.20 18 15.30 754 208 2.87 / 27.56 2 3
6 8 0.28 175 15.33 267 716 3.58 / 28.27 2 2
Average= 3.53
(KJ/cycle)

Cycle 6 GMT 2/10/2020 10: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 15.28 427 189 0.19 / 21.17 2 3
2 7 2003.88 33 15.04 2947 1463 1.65 / 22.63 2 3
3 13 1461.08 18 15.10 2261 615 2.27 / 23.25 2 3
4 13 1023.28 18 15.15 1681 458 2.72 / 23.71 2 3
5 13 269.12 18 15.31 648 179 2.90 / 23.89 2 3
6 8 0.12 175 15.34 269 722 3.63 / 24.61 2 4
7 14 0.12 20 15.32 272 83 3.71 / 24.69 2 2
Average= 3.53
(KJ/cycle)

Cycle 5 GMT 1/10/2020 9:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 28 15.28 447 191 0.19 / 16.61 2 3
2 7 2003.44 74 14.90 2946 3248 3.44 / 19.86 2 3
3 13 188.72 18 15.33 541 149 3.59 / 20.01 2 3
4 8 -0.04 165 15.33 265 670 4.26 / 20.68 2 3
5 14 -0.04 75 15.30 263 302 4.56 / 20.98 2 3
Average= 3.50
(KJ/cycle)

Cycle 4 GMT 30/ 9/2020 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 15.27 424 181 0.18 / 11.96 2 3
2 3 1038.44 1 15.33 1776 27 0.21 / 11.99 2 3
3 7 2007.52 75 14.91 2949 3298 3.51 / 15.29 2 3
4 13 173.60 18 15.33 520 143 3.65 / 15.43 2 3
5 8 -0.24 165 15.34 270 683 4.33 / 16.11 2 3
6 14 -0.24 75 15.31 267 307 4.64 / 16.42 2 3
Average= 3.28
(KJ/cycle)

Cycle 3 GMT 29/ 9/2020 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 15.31 428 183 0.18 / 7.37 2 3
2 7 2002.68 75 14.88 2940 3281 3.46 / 10.65 2 3
3 13 188.72 18 15.32 545 150 3.61 / 10.80 2 3
4 8 -0.16 165 15.32 267 675 4.29 / 11.47 2 3
5 14 -0.16 75 15.30 269 309 4.60 / 11.78 2 4
Average= 2.95
(KJ/cycle)

Cycle 2 GMT 28/ 9/2020 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 15.28 431 178 0.18 / 4.66 2 3
2 3 1023.76 1 15.31 1748 27 0.20 / 4.69 2 3
3 7 1004.68 74 15.20 1621 1823 2.03 / 6.51 2 3
4 8 0.00 165 15.36 266 674 2.70 / 7.18 2 2
Average= 2.39
(KJ/cycle)

Cycle 1 GMT 27/ 9/2020 15:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 24 15.46 419 155 0.16 / 1.91 2 3
2 10 1010.84 3 15.31 1696 78 0.23 / 1.98 2 3
3 7 1006.00 74 15.19 1622 1823 2.06 / 3.81 2 3
4 8 0.20 165 15.35 266 674 2.73 / 4.48 2 3
Average= 2.24
(KJ/cycle)

Cycle 0 GMT 27/ 9/2020 4:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.60 24 15.57 503 188 0.19 / 0.19 2 3
2 7 175.96 74 15.55 513 590 0.78 / 0.78 2 3
3 8 0.24 240 15.53 261 973 1.75 / 1.75 2 5
Average= 1.75
(KJ/cycle)