SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 34 | 14.95 | 425 | 216 | 0.22 / 587.92 | 2 | 2 |
2 | 12 | 1291.24 | 3 | 15.15 | 2030 | 92 | 0.31 / 588.01 | 2 | 2 |
3 | 7 | 2003.20 | 31 | 14.79 | 2826 | 1296 | 1.60 / 589.31 | 2 | 2 |
4 | 13 | 1585.36 | 19 | 14.78 | 2324 | 653 | 2.26 / 589.96 | 2 | 3 |
5 | 13 | 1145.36 | 19 | 14.81 | 1777 | 500 | 2.76 / 590.46 | 2 | 5 |
6 | 13 | 399.32 | 19 | 14.95 | 813 | 231 | 2.99 / 590.69 | 2 | 4 |
7 | 8 | 0.36 | 180 | 15.00 | 261 | 705 | 3.69 / 591.40 | 2 | 5 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 34 | 14.97 | 430 | 219 | 0.22 / 584.21 | 2 | 2 |
2 | 12 | 1288.16 | 3 | 15.15 | 2044 | 93 | 0.31 / 584.31 | 2 | 2 |
3 | 7 | 2003.64 | 31 | 14.79 | 2833 | 1299 | 1.61 / 585.60 | 2 | 2 |
4 | 13 | 1598.00 | 19 | 14.78 | 2353 | 661 | 2.27 / 586.27 | 2 | 3 |
5 | 13 | 1146.24 | 19 | 14.81 | 1788 | 503 | 2.77 / 586.77 | 2 | 4 |
6 | 13 | 411.64 | 19 | 14.96 | 829 | 236 | 3.01 / 587.00 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.00 | 260 | 702 | 3.71 / 587.71 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 34 | 14.99 | 424 | 216 | 0.22 / 580.50 | 2 | 2 |
2 | 12 | 1289.56 | 3 | 15.15 | 2054 | 93 | 0.31 / 580.59 | 2 | 2 |
3 | 7 | 2003.12 | 31 | 14.81 | 2835 | 1302 | 1.61 / 581.90 | 2 | 3 |
4 | 13 | 1590.00 | 19 | 14.80 | 2342 | 659 | 2.27 / 582.55 | 2 | 3 |
5 | 13 | 1040.24 | 19 | 14.84 | 1655 | 467 | 2.74 / 583.02 | 2 | 3 |
6 | 13 | 448.36 | 19 | 14.96 | 883 | 251 | 2.99 / 583.27 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.02 | 267 | 722 | 3.71 / 583.99 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 34 | 14.99 | 424 | 216 | 0.22 / 576.80 | 2 | 2 |
2 | 12 | 1283.40 | 3 | 15.16 | 2037 | 93 | 0.31 / 576.89 | 2 | 2 |
3 | 7 | 2003.56 | 31 | 14.82 | 2843 | 1306 | 1.61 / 578.20 | 2 | 3 |
4 | 13 | 1589.44 | 19 | 14.81 | 2334 | 657 | 2.27 / 578.86 | 2 | 3 |
5 | 13 | 1030.08 | 19 | 14.85 | 1643 | 464 | 2.74 / 579.32 | 2 | 4 |
6 | 13 | 449.16 | 19 | 14.97 | 888 | 253 | 2.99 / 579.57 | 2 | 3 |
7 | 8 | 0.32 | 180 | 15.02 | 263 | 711 | 3.70 / 580.28 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 34 | 14.98 | 434 | 221 | 0.22 / 572.98 | 2 | 2 |
2 | 12 | 1280.44 | 3 | 15.17 | 2034 | 93 | 0.31 / 573.08 | 2 | 2 |
3 | 7 | 2002.60 | 32 | 14.80 | 2831 | 1341 | 1.65 / 574.42 | 2 | 3 |
4 | 13 | 1590.88 | 19 | 14.80 | 2345 | 659 | 2.31 / 575.08 | 2 | 3 |
5 | 13 | 1028.20 | 19 | 14.84 | 1644 | 464 | 2.78 / 575.54 | 2 | 3 |
6 | 13 | 437.24 | 19 | 14.96 | 872 | 248 | 3.03 / 575.79 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.03 | 266 | 720 | 3.74 / 576.51 | 2 | 4 |
8 | 14 | -0.12 | 20 | 15.01 | 260 | 78 | 3.82 / 576.59 | 3 | 6 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 34 | 14.99 | 432 | 220 | 0.22 / 569.20 | 2 | 2 |
2 | 12 | 1277.00 | 3 | 15.16 | 2034 | 93 | 0.31 / 569.29 | 2 | 2 |
3 | 7 | 2007.28 | 31 | 14.81 | 2833 | 1301 | 1.61 / 570.59 | 2 | 3 |
4 | 13 | 1587.92 | 19 | 14.80 | 2334 | 656 | 2.27 / 571.25 | 2 | 3 |
5 | 13 | 1026.80 | 19 | 14.85 | 1648 | 465 | 2.73 / 571.71 | 2 | 4 |
6 | 13 | 437.60 | 19 | 14.96 | 868 | 247 | 2.98 / 571.96 | 2 | 4 |
7 | 8 | 0.04 | 180 | 15.03 | 267 | 722 | 3.70 / 572.68 | 2 | 6 |
8 | 14 | 0.04 | 20 | 15.01 | 269 | 81 | 3.78 / 572.76 | 4 | 9 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 34 | 14.97 | 426 | 217 | 0.22 / 565.48 | 2 | 2 |
2 | 12 | 1274.80 | 3 | 15.17 | 2026 | 92 | 0.31 / 565.58 | 2 | 2 |
3 | 7 | 2002.72 | 31 | 14.83 | 2842 | 1307 | 1.62 / 566.88 | 2 | 2 |
4 | 13 | 1583.72 | 19 | 14.82 | 2347 | 661 | 2.28 / 567.54 | 2 | 3 |
5 | 13 | 1022.00 | 19 | 14.86 | 1645 | 464 | 2.74 / 568.01 | 2 | 4 |
6 | 13 | 437.92 | 19 | 14.97 | 881 | 251 | 2.99 / 568.26 | 2 | 3 |
7 | 8 | 0.40 | 180 | 15.03 | 266 | 720 | 3.71 / 568.98 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 34 | 14.99 | 429 | 219 | 0.22 / 561.78 | 2 | 2 |
2 | 12 | 1280.96 | 3 | 15.16 | 2039 | 93 | 0.31 / 561.88 | 2 | 2 |
3 | 7 | 2002.56 | 31 | 14.81 | 2832 | 1300 | 1.61 / 563.18 | 2 | 2 |
4 | 13 | 1584.60 | 19 | 14.81 | 2341 | 659 | 2.27 / 563.83 | 2 | 3 |
5 | 13 | 1021.44 | 19 | 14.85 | 1637 | 462 | 2.73 / 564.30 | 2 | 5 |
6 | 13 | 439.32 | 19 | 14.97 | 876 | 249 | 2.98 / 564.55 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.03 | 267 | 722 | 3.70 / 565.27 | 2 | 9 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 34 | 14.99 | 423 | 216 | 0.22 / 557.99 | 2 | 2 |
2 | 12 | 1274.60 | 3 | 15.18 | 2041 | 93 | 0.31 / 558.08 | 2 | 2 |
3 | 7 | 2003.12 | 31 | 14.81 | 2834 | 1301 | 1.61 / 559.39 | 2 | 2 |
4 | 13 | 1586.80 | 19 | 14.81 | 2336 | 657 | 2.27 / 560.04 | 2 | 3 |
5 | 13 | 1025.44 | 19 | 14.85 | 1635 | 461 | 2.73 / 560.50 | 2 | 5 |
6 | 13 | 446.76 | 19 | 14.96 | 892 | 254 | 2.98 / 560.76 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.03 | 268 | 725 | 3.71 / 561.48 | 2 | 8 |
8 | 14 | -0.12 | 20 | 15.01 | 269 | 81 | 3.79 / 561.56 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 34 | 14.99 | 435 | 222 | 0.22 / 554.25 | 2 | 2 |
2 | 12 | 1281.04 | 3 | 15.15 | 2021 | 92 | 0.31 / 554.34 | 2 | 2 |
3 | 7 | 2002.88 | 31 | 14.82 | 2837 | 1303 | 1.62 / 555.64 | 2 | 2 |
4 | 13 | 1596.44 | 19 | 14.80 | 2347 | 660 | 2.28 / 556.30 | 2 | 3 |
5 | 13 | 1160.08 | 19 | 14.83 | 1807 | 509 | 2.79 / 556.81 | 2 | 4 |
6 | 13 | 428.60 | 19 | 14.97 | 857 | 244 | 3.03 / 557.05 | 2 | 4 |
7 | 8 | 0.56 | 180 | 15.02 | 267 | 722 | 3.75 / 557.78 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 34 | 14.98 | 439 | 224 | 0.22 / 550.44 | 2 | 2 |
2 | 12 | 1281.12 | 3 | 15.17 | 2028 | 92 | 0.32 / 550.54 | 2 | 2 |
3 | 7 | 2002.24 | 31 | 14.82 | 2831 | 1301 | 1.62 / 551.84 | 2 | 2 |
4 | 13 | 1581.68 | 19 | 14.81 | 2333 | 656 | 2.27 / 552.49 | 2 | 3 |
5 | 13 | 1143.44 | 19 | 14.83 | 1791 | 505 | 2.78 / 553.00 | 2 | 3 |
6 | 13 | 398.32 | 19 | 14.98 | 814 | 232 | 3.01 / 553.23 | 2 | 4 |
7 | 8 | 0.00 | 180 | 15.03 | 264 | 714 | 3.72 / 553.94 | 2 | 5 |
8 | 14 | 0.00 | 20 | 15.01 | 270 | 81 | 3.80 / 554.02 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 34 | 14.98 | 443 | 226 | 0.23 / 546.65 | 2 | 2 |
2 | 12 | 1280.40 | 3 | 15.17 | 2034 | 93 | 0.32 / 546.74 | 2 | 2 |
3 | 7 | 2007.08 | 32 | 14.81 | 2842 | 1347 | 1.67 / 548.09 | 2 | 2 |
4 | 13 | 1600.40 | 19 | 14.81 | 2362 | 665 | 2.33 / 548.75 | 2 | 3 |
5 | 13 | 1031.40 | 19 | 14.86 | 1649 | 466 | 2.80 / 549.22 | 2 | 4 |
6 | 13 | 331.12 | 19 | 14.99 | 731 | 208 | 3.00 / 549.43 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.03 | 263 | 712 | 3.72 / 550.14 | 2 | 5 |
8 | 14 | 0.04 | 20 | 15.01 | 266 | 80 | 3.79 / 550.22 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 34 | 14.99 | 435 | 222 | 0.22 / 542.82 | 2 | 2 |
2 | 12 | 1277.20 | 3 | 15.17 | 2041 | 93 | 0.31 / 542.91 | 2 | 2 |
3 | 7 | 2002.72 | 31 | 14.82 | 2831 | 1301 | 1.62 / 544.21 | 2 | 3 |
4 | 13 | 1598.32 | 19 | 14.81 | 2354 | 662 | 2.28 / 544.88 | 2 | 3 |
5 | 13 | 1033.16 | 19 | 14.86 | 1653 | 467 | 2.74 / 545.34 | 2 | 4 |
6 | 13 | 454.76 | 19 | 14.96 | 889 | 253 | 3.00 / 545.60 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.03 | 276 | 747 | 3.74 / 546.34 | 2 | 6 |
8 | 14 | 0.08 | 20 | 15.01 | 275 | 83 | 3.83 / 546.43 | 4 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 34 | 14.99 | 416 | 212 | 0.21 / 539.04 | 2 | 2 |
2 | 12 | 1291.12 | 3 | 15.16 | 2065 | 94 | 0.31 / 539.13 | 2 | 2 |
3 | 7 | 2003.48 | 31 | 14.82 | 2834 | 1302 | 1.61 / 540.43 | 2 | 2 |
4 | 13 | 1588.20 | 19 | 14.81 | 2347 | 660 | 2.27 / 541.09 | 2 | 3 |
5 | 13 | 1030.80 | 19 | 14.86 | 1642 | 464 | 2.73 / 541.56 | 2 | 4 |
6 | 13 | 447.84 | 19 | 14.96 | 878 | 250 | 2.98 / 541.81 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.03 | 263 | 712 | 3.69 / 542.52 | 2 | 10 |
8 | 14 | -0.12 | 20 | 15.01 | 266 | 80 | 3.77 / 542.60 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 34 | 14.99 | 420 | 214 | 0.21 / 535.29 | 2 | 2 |
2 | 12 | 1288.16 | 3 | 15.16 | 2045 | 93 | 0.31 / 535.38 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.84 | 2837 | 1305 | 1.61 / 536.69 | 2 | 2 |
4 | 13 | 1595.36 | 19 | 14.81 | 2353 | 662 | 2.27 / 537.35 | 2 | 3 |
5 | 13 | 1168.68 | 19 | 14.84 | 1813 | 511 | 2.79 / 537.86 | 2 | 6 |
6 | 13 | 434.28 | 19 | 14.98 | 861 | 245 | 3.03 / 538.10 | 2 | 3 |
7 | 8 | 0.00 | 180 | 15.03 | 267 | 722 | 3.75 / 538.83 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 34 | 14.99 | 405 | 206 | 0.21 / 531.59 | 2 | 2 |
2 | 12 | 1289.04 | 3 | 15.16 | 2056 | 94 | 0.30 / 531.68 | 2 | 2 |
3 | 7 | 2003.44 | 31 | 14.83 | 2840 | 1306 | 1.61 / 532.99 | 2 | 3 |
4 | 13 | 1589.72 | 19 | 14.81 | 2347 | 660 | 2.27 / 533.65 | 2 | 3 |
5 | 13 | 1019.52 | 19 | 14.86 | 1634 | 461 | 2.73 / 534.11 | 2 | 6 |
6 | 13 | 432.24 | 19 | 14.97 | 868 | 247 | 2.97 / 534.35 | 2 | 3 |
7 | 8 | 0.28 | 180 | 15.02 | 266 | 719 | 3.69 / 535.07 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 34 | 14.97 | 434 | 221 | 0.22 / 527.79 | 2 | 2 |
2 | 12 | 1286.56 | 3 | 15.15 | 2041 | 93 | 0.31 / 527.88 | 2 | 2 |
3 | 7 | 2002.84 | 31 | 14.81 | 2820 | 1295 | 1.61 / 529.18 | 2 | 3 |
4 | 13 | 1592.40 | 19 | 14.80 | 2346 | 660 | 2.27 / 529.84 | 2 | 4 |
5 | 13 | 1150.32 | 19 | 14.82 | 1795 | 505 | 2.77 / 530.34 | 2 | 4 |
6 | 13 | 412.60 | 19 | 14.97 | 834 | 237 | 3.01 / 530.58 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.03 | 266 | 720 | 3.73 / 531.30 | 2 | 8 |
8 | 14 | 0.20 | 20 | 15.01 | 267 | 80 | 3.81 / 531.38 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 34 | 14.99 | 425 | 217 | 0.22 / 524.10 | 2 | 2 |
2 | 12 | 1286.44 | 3 | 15.18 | 2019 | 92 | 0.31 / 524.19 | 2 | 2 |
3 | 7 | 2002.76 | 31 | 14.82 | 2830 | 1300 | 1.61 / 525.49 | 2 | 2 |
4 | 13 | 1590.76 | 19 | 14.81 | 2334 | 657 | 2.27 / 526.15 | 2 | 3 |
5 | 13 | 1025.84 | 19 | 14.86 | 1629 | 460 | 2.73 / 526.61 | 2 | 5 |
6 | 13 | 438.00 | 19 | 14.97 | 865 | 246 | 2.97 / 526.86 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.04 | 263 | 712 | 3.68 / 527.57 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 34 | 14.98 | 415 | 211 | 0.21 / 520.41 | 2 | 2 |
2 | 12 | 1286.68 | 3 | 15.17 | 2047 | 93 | 0.30 / 520.50 | 2 | 2 |
3 | 7 | 2005.32 | 31 | 14.82 | 2836 | 1303 | 1.61 / 521.80 | 2 | 2 |
4 | 13 | 1588.84 | 19 | 14.82 | 2329 | 656 | 2.26 / 522.46 | 2 | 3 |
5 | 13 | 1027.08 | 19 | 14.86 | 1632 | 461 | 2.72 / 522.92 | 2 | 3 |
6 | 13 | 446.04 | 19 | 14.97 | 871 | 248 | 2.97 / 523.17 | 2 | 4 |
7 | 8 | 0.08 | 180 | 15.03 | 265 | 717 | 3.69 / 523.89 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 34 | 14.99 | 420 | 214 | 0.21 / 516.66 | 2 | 2 |
2 | 12 | 1280.68 | 3 | 15.16 | 2048 | 93 | 0.31 / 516.75 | 2 | 2 |
3 | 7 | 2003.12 | 31 | 14.83 | 2826 | 1299 | 1.61 / 518.05 | 2 | 2 |
4 | 13 | 1589.52 | 19 | 14.82 | 2336 | 658 | 2.26 / 518.71 | 2 | 3 |
5 | 13 | 1025.52 | 19 | 14.86 | 1635 | 462 | 2.73 / 519.17 | 2 | 5 |
6 | 13 | 445.24 | 19 | 14.97 | 869 | 247 | 2.97 / 519.42 | 2 | 3 |
7 | 13 | 24.36 | 19 | 15.06 | 305 | 87 | 3.06 / 519.50 | 2 | 3 |
8 | 8 | 0.20 | 180 | 15.03 | 256 | 693 | 3.75 / 520.20 | 2 | 9 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 34 | 14.99 | 427 | 218 | 0.22 / 512.96 | 2 | 2 |
2 | 12 | 1280.36 | 3 | 15.17 | 2021 | 92 | 0.31 / 513.05 | 2 | 2 |
3 | 7 | 2001.92 | 31 | 14.84 | 2835 | 1304 | 1.61 / 514.36 | 2 | 3 |
4 | 13 | 1586.80 | 19 | 14.82 | 2335 | 657 | 2.27 / 515.02 | 2 | 4 |
5 | 13 | 1037.44 | 19 | 14.86 | 1648 | 465 | 2.74 / 515.48 | 2 | 4 |
6 | 13 | 453.92 | 19 | 14.97 | 883 | 251 | 2.99 / 515.73 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.03 | 263 | 712 | 3.70 / 516.44 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 34 | 14.98 | 422 | 215 | 0.21 / 509.26 | 2 | 2 |
2 | 12 | 1288.12 | 3 | 15.17 | 2046 | 93 | 0.31 / 509.36 | 2 | 2 |
3 | 7 | 2003.20 | 31 | 14.81 | 2830 | 1299 | 1.61 / 510.66 | 2 | 3 |
4 | 13 | 1588.76 | 19 | 14.81 | 2325 | 654 | 2.26 / 511.31 | 2 | 3 |
5 | 13 | 1029.92 | 19 | 14.86 | 1632 | 461 | 2.72 / 511.77 | 2 | 5 |
6 | 13 | 444.64 | 19 | 14.97 | 869 | 247 | 2.97 / 512.02 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.03 | 269 | 728 | 3.70 / 512.75 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 34 | 14.99 | 427 | 218 | 0.22 / 505.58 | 2 | 2 |
2 | 12 | 1278.52 | 3 | 15.17 | 2042 | 93 | 0.31 / 505.67 | 2 | 2 |
3 | 7 | 2007.96 | 32 | 14.81 | 2841 | 1346 | 1.66 / 507.02 | 2 | 3 |
4 | 13 | 1597.12 | 19 | 14.81 | 2338 | 658 | 2.31 / 507.68 | 2 | 4 |
5 | 13 | 1032.36 | 19 | 14.85 | 1645 | 464 | 2.78 / 508.14 | 2 | 3 |
6 | 13 | 331.36 | 19 | 15.00 | 728 | 207 | 2.99 / 508.35 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.03 | 259 | 701 | 3.69 / 509.05 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 34 | 14.98 | 426 | 217 | 0.22 / 501.84 | 2 | 2 |
2 | 12 | 1264.84 | 3 | 15.18 | 2005 | 91 | 0.31 / 501.93 | 2 | 2 |
3 | 7 | 2002.12 | 31 | 14.83 | 2839 | 1305 | 1.61 / 503.24 | 2 | 4 |
4 | 13 | 1597.12 | 19 | 14.83 | 2350 | 662 | 2.28 / 503.90 | 2 | 3 |
5 | 13 | 1154.64 | 19 | 14.85 | 1796 | 507 | 2.78 / 504.41 | 2 | 4 |
6 | 13 | 421.32 | 19 | 14.98 | 845 | 241 | 3.02 / 504.65 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.04 | 263 | 712 | 3.73 / 505.36 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 34 | 14.98 | 427 | 217 | 0.22 / 498.14 | 2 | 2 |
2 | 12 | 1262.60 | 3 | 15.18 | 2015 | 92 | 0.31 / 498.23 | 2 | 2 |
3 | 7 | 2007.32 | 31 | 14.81 | 2826 | 1297 | 1.61 / 499.53 | 2 | 3 |
4 | 13 | 1589.24 | 19 | 14.80 | 2339 | 658 | 2.26 / 500.19 | 2 | 5 |
5 | 13 | 1141.56 | 19 | 14.84 | 1781 | 502 | 2.77 / 500.69 | 2 | 5 |
6 | 13 | 397.08 | 19 | 14.99 | 808 | 230 | 3.00 / 500.92 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.04 | 261 | 707 | 3.70 / 501.63 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 34 | 14.98 | 417 | 212 | 0.21 / 494.50 | 2 | 2 |
2 | 12 | 1278.64 | 3 | 15.16 | 2032 | 92 | 0.30 / 494.59 | 2 | 2 |
3 | 7 | 2003.88 | 31 | 14.83 | 2830 | 1301 | 1.61 / 495.90 | 2 | 3 |
4 | 13 | 1587.32 | 19 | 14.82 | 2336 | 658 | 2.26 / 496.55 | 2 | 4 |
5 | 13 | 1025.56 | 19 | 14.86 | 1631 | 460 | 2.72 / 497.01 | 2 | 5 |
6 | 13 | 313.68 | 19 | 15.00 | 700 | 199 | 2.92 / 497.21 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.03 | 262 | 709 | 3.63 / 497.92 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 34 | 14.99 | 435 | 222 | 0.22 / 490.71 | 2 | 2 |
2 | 12 | 1271.20 | 3 | 15.17 | 2012 | 92 | 0.31 / 490.80 | 2 | 2 |
3 | 7 | 2007.36 | 31 | 14.84 | 2838 | 1306 | 1.62 / 492.11 | 2 | 2 |
4 | 13 | 1600.40 | 19 | 14.82 | 2345 | 660 | 2.28 / 492.77 | 2 | 3 |
5 | 13 | 1058.00 | 19 | 14.85 | 1678 | 473 | 2.75 / 493.24 | 2 | 4 |
6 | 13 | 472.24 | 19 | 14.97 | 910 | 259 | 3.01 / 493.50 | 2 | 4 |
7 | 8 | 0.12 | 180 | 15.03 | 263 | 712 | 3.72 / 494.21 | 2 | 8 |
8 | 14 | 0.12 | 20 | 15.01 | 263 | 79 | 3.80 / 494.29 | 2 | 12 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 34 | 14.99 | 436 | 222 | 0.22 / 486.93 | 2 | 2 |
2 | 12 | 1259.48 | 3 | 15.18 | 2001 | 91 | 0.31 / 487.03 | 2 | 2 |
3 | 7 | 2007.40 | 32 | 14.83 | 2839 | 1347 | 1.66 / 488.37 | 2 | 3 |
4 | 13 | 1596.04 | 19 | 14.83 | 2342 | 660 | 2.32 / 489.03 | 2 | 3 |
5 | 13 | 1155.20 | 19 | 14.85 | 1791 | 505 | 2.83 / 489.54 | 2 | 4 |
6 | 13 | 418.00 | 19 | 14.99 | 834 | 238 | 3.06 / 489.78 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.04 | 263 | 712 | 3.78 / 490.49 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 34 | 15.00 | 421 | 215 | 0.21 / 483.25 | 2 | 2 |
2 | 12 | 1261.68 | 3 | 15.19 | 1988 | 91 | 0.31 / 483.34 | 2 | 2 |
3 | 7 | 2007.80 | 31 | 14.82 | 2839 | 1304 | 1.61 / 484.64 | 2 | 3 |
4 | 13 | 1587.72 | 19 | 14.82 | 2323 | 654 | 2.26 / 485.30 | 2 | 4 |
5 | 13 | 1021.96 | 19 | 14.87 | 1621 | 458 | 2.72 / 485.76 | 2 | 4 |
6 | 13 | 442.84 | 19 | 14.98 | 869 | 247 | 2.97 / 486.00 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.04 | 262 | 709 | 3.68 / 486.71 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 34 | 14.99 | 421 | 215 | 0.21 / 479.58 | 2 | 2 |
2 | 12 | 1267.72 | 3 | 15.19 | 2007 | 91 | 0.31 / 479.67 | 2 | 2 |
3 | 7 | 2002.84 | 31 | 14.83 | 2828 | 1300 | 1.61 / 480.97 | 2 | 3 |
4 | 13 | 1593.88 | 19 | 14.82 | 2331 | 656 | 2.26 / 481.63 | 2 | 3 |
5 | 13 | 1020.12 | 19 | 14.87 | 1621 | 458 | 2.72 / 482.09 | 2 | 5 |
6 | 13 | 428.16 | 19 | 14.98 | 849 | 242 | 2.96 / 482.33 | 2 | 3 |
7 | 8 | 0.40 | 180 | 15.04 | 260 | 704 | 3.67 / 483.03 | 2 | 9 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 34 | 14.99 | 422 | 215 | 0.22 / 475.88 | 2 | 2 |
2 | 12 | 1271.12 | 3 | 15.19 | 2015 | 92 | 0.31 / 475.97 | 2 | 2 |
3 | 7 | 2001.84 | 32 | 14.83 | 2831 | 1343 | 1.65 / 477.31 | 2 | 2 |
4 | 13 | 1585.36 | 19 | 14.82 | 2319 | 653 | 2.30 / 477.97 | 2 | 4 |
5 | 13 | 1023.96 | 19 | 14.86 | 1627 | 459 | 2.76 / 478.43 | 2 | 4 |
6 | 13 | 436.00 | 19 | 14.98 | 859 | 244 | 3.01 / 478.67 | 2 | 4 |
7 | 8 | -0.16 | 180 | 15.03 | 258 | 698 | 3.71 / 479.37 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 34 | 14.99 | 414 | 211 | 0.21 / 472.18 | 2 | 2 |
2 | 12 | 1263.64 | 3 | 15.18 | 2003 | 91 | 0.30 / 472.27 | 2 | 2 |
3 | 7 | 2004.92 | 31 | 14.83 | 2831 | 1301 | 1.60 / 473.57 | 2 | 3 |
4 | 13 | 1586.36 | 19 | 14.82 | 2325 | 655 | 2.26 / 474.22 | 2 | 4 |
5 | 13 | 1144.40 | 19 | 14.85 | 1777 | 501 | 2.76 / 474.72 | 2 | 4 |
6 | 13 | 408.72 | 19 | 14.99 | 824 | 235 | 2.99 / 474.96 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.04 | 260 | 704 | 3.70 / 475.66 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 34 | 14.99 | 416 | 212 | 0.21 / 468.50 | 2 | 2 |
2 | 12 | 1275.68 | 3 | 15.17 | 2020 | 92 | 0.30 / 468.59 | 2 | 2 |
3 | 7 | 2004.20 | 31 | 14.83 | 2819 | 1296 | 1.60 / 469.89 | 2 | 3 |
4 | 13 | 1589.48 | 19 | 14.82 | 2324 | 654 | 2.25 / 470.55 | 2 | 4 |
5 | 13 | 1028.40 | 19 | 14.87 | 1630 | 461 | 2.71 / 471.01 | 2 | 4 |
6 | 13 | 438.40 | 19 | 14.98 | 870 | 248 | 2.96 / 471.25 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.03 | 263 | 712 | 3.67 / 471.96 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 34 | 14.99 | 428 | 218 | 0.22 / 464.83 | 2 | 2 |
2 | 12 | 1264.40 | 3 | 15.20 | 2015 | 92 | 0.31 / 464.92 | 2 | 2 |
3 | 7 | 2004.48 | 31 | 14.84 | 2825 | 1300 | 1.61 / 466.22 | 2 | 3 |
4 | 13 | 1596.72 | 19 | 14.83 | 2344 | 660 | 2.27 / 466.88 | 2 | 3 |
5 | 13 | 1032.40 | 19 | 14.87 | 1635 | 462 | 2.73 / 467.34 | 2 | 6 |
6 | 13 | 444.08 | 19 | 14.98 | 868 | 247 | 2.98 / 467.59 | 2 | 3 |
7 | 8 | -0.08 | 180 | 15.04 | 259 | 701 | 3.68 / 468.29 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 34 | 15.00 | 417 | 213 | 0.21 / 461.14 | 2 | 2 |
2 | 12 | 1267.00 | 3 | 15.19 | 1995 | 91 | 0.30 / 461.23 | 2 | 2 |
3 | 7 | 2002.40 | 31 | 14.83 | 2824 | 1298 | 1.60 / 462.53 | 2 | 3 |
4 | 13 | 1591.84 | 19 | 14.82 | 2323 | 654 | 2.26 / 463.18 | 2 | 4 |
5 | 13 | 1040.36 | 19 | 14.87 | 1650 | 466 | 2.72 / 463.65 | 2 | 6 |
6 | 13 | 449.16 | 19 | 14.98 | 876 | 249 | 2.97 / 463.90 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.03 | 263 | 712 | 3.68 / 464.61 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 34 | 15.02 | 422 | 216 | 0.22 / 457.40 | 2 | 2 |
2 | 12 | 1266.72 | 3 | 15.19 | 2017 | 92 | 0.31 / 457.49 | 2 | 2 |
3 | 7 | 2007.76 | 31 | 14.85 | 2827 | 1301 | 1.61 / 458.79 | 2 | 3 |
4 | 13 | 1730.20 | 19 | 14.81 | 2498 | 703 | 2.31 / 459.49 | 2 | 4 |
5 | 13 | 1127.36 | 19 | 14.87 | 1756 | 496 | 2.81 / 459.99 | 2 | 5 |
6 | 13 | 410.76 | 19 | 14.99 | 826 | 235 | 3.04 / 460.22 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.05 | 260 | 704 | 3.75 / 460.93 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 34 | 15.00 | 419 | 214 | 0.21 / 453.71 | 2 | 2 |
2 | 12 | 1269.24 | 3 | 15.19 | 2020 | 92 | 0.31 / 453.80 | 2 | 2 |
3 | 7 | 2008.20 | 32 | 14.84 | 2827 | 1342 | 1.65 / 455.14 | 2 | 3 |
4 | 13 | 1592.00 | 19 | 14.84 | 2335 | 658 | 2.31 / 455.80 | 2 | 3 |
5 | 13 | 1039.92 | 19 | 14.88 | 1650 | 466 | 2.77 / 456.26 | 2 | 6 |
6 | 13 | 328.68 | 19 | 15.02 | 720 | 205 | 2.98 / 456.47 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.05 | 262 | 710 | 3.69 / 457.18 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 34 | 15.01 | 416 | 212 | 0.21 / 450.02 | 2 | 2 |
2 | 12 | 1271.68 | 3 | 15.19 | 2015 | 92 | 0.30 / 450.12 | 2 | 2 |
3 | 7 | 2002.24 | 31 | 14.84 | 2824 | 1299 | 1.60 / 451.42 | 2 | 3 |
4 | 13 | 1595.04 | 19 | 14.83 | 2336 | 658 | 2.26 / 452.07 | 2 | 4 |
5 | 13 | 1028.04 | 19 | 14.89 | 1638 | 463 | 2.72 / 452.54 | 2 | 6 |
6 | 13 | 438.80 | 19 | 14.99 | 859 | 245 | 2.97 / 452.78 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.06 | 262 | 710 | 3.68 / 453.49 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 34 | 15.01 | 429 | 219 | 0.22 / 446.33 | 2 | 2 |
2 | 12 | 1259.32 | 3 | 15.20 | 2013 | 92 | 0.31 / 446.42 | 2 | 2 |
3 | 7 | 2002.36 | 31 | 14.84 | 2831 | 1302 | 1.61 / 447.72 | 2 | 3 |
4 | 13 | 1578.92 | 19 | 14.84 | 2319 | 654 | 2.27 / 448.37 | 2 | 6 |
5 | 13 | 1141.16 | 19 | 14.86 | 1777 | 502 | 2.77 / 448.88 | 2 | 5 |
6 | 13 | 398.48 | 19 | 15.00 | 814 | 232 | 3.00 / 449.11 | 2 | 3 |
7 | 8 | -0.04 | 180 | 15.06 | 260 | 705 | 3.71 / 449.81 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 34 | 14.99 | 428 | 218 | 0.22 / 442.63 | 2 | 2 |
2 | 12 | 1266.88 | 3 | 15.19 | 2020 | 92 | 0.31 / 442.72 | 2 | 2 |
3 | 7 | 2005.64 | 31 | 14.84 | 2836 | 1305 | 1.61 / 444.02 | 2 | 3 |
4 | 13 | 1585.64 | 19 | 14.84 | 2333 | 658 | 2.27 / 444.68 | 2 | 5 |
5 | 13 | 1023.08 | 19 | 14.89 | 1637 | 463 | 2.74 / 445.14 | 2 | 3 |
6 | 13 | 429.40 | 19 | 14.99 | 857 | 244 | 2.98 / 445.39 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.05 | 265 | 718 | 3.70 / 446.11 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 34 | 15.00 | 431 | 220 | 0.22 / 438.93 | 2 | 2 |
2 | 12 | 1272.00 | 3 | 15.20 | 2017 | 92 | 0.31 / 439.02 | 2 | 2 |
3 | 7 | 2003.68 | 31 | 14.85 | 2825 | 1300 | 1.61 / 440.32 | 2 | 3 |
4 | 13 | 1595.16 | 19 | 14.83 | 2353 | 663 | 2.28 / 440.98 | 2 | 3 |
5 | 13 | 1027.08 | 19 | 14.88 | 1641 | 464 | 2.74 / 441.44 | 2 | 4 |
6 | 13 | 442.88 | 19 | 14.99 | 876 | 249 | 2.99 / 441.69 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.04 | 264 | 715 | 3.70 / 442.41 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 34 | 15.02 | 422 | 216 | 0.22 / 435.20 | 2 | 2 |
2 | 12 | 1261.84 | 3 | 15.19 | 2017 | 92 | 0.31 / 435.29 | 2 | 2 |
3 | 7 | 2003.36 | 31 | 14.84 | 2827 | 1301 | 1.61 / 436.59 | 2 | 3 |
4 | 13 | 1585.28 | 19 | 14.84 | 2328 | 656 | 2.26 / 437.25 | 2 | 3 |
5 | 13 | 1145.44 | 19 | 14.87 | 1786 | 505 | 2.77 / 437.75 | 2 | 5 |
6 | 13 | 403.44 | 19 | 15.00 | 822 | 234 | 3.00 / 437.99 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.06 | 265 | 718 | 3.72 / 438.71 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 34 | 15.00 | 430 | 219 | 0.22 / 431.45 | 2 | 2 |
2 | 12 | 1270.64 | 3 | 15.19 | 2012 | 92 | 0.31 / 431.54 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.84 | 2829 | 1301 | 1.61 / 432.84 | 2 | 3 |
4 | 13 | 1590.88 | 19 | 14.83 | 2333 | 657 | 2.27 / 433.50 | 2 | 5 |
5 | 13 | 1150.68 | 19 | 14.86 | 1800 | 508 | 2.78 / 434.01 | 2 | 5 |
6 | 13 | 287.92 | 19 | 15.02 | 670 | 191 | 2.97 / 434.20 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.05 | 260 | 704 | 3.67 / 434.90 | 2 | 8 |
8 | 14 | 0.08 | 20 | 15.03 | 265 | 80 | 3.75 / 434.98 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 34 | 15.01 | 431 | 220 | 0.22 / 427.78 | 2 | 2 |
2 | 12 | 1269.92 | 3 | 15.20 | 2004 | 91 | 0.31 / 427.87 | 2 | 2 |
3 | 7 | 2007.68 | 31 | 14.86 | 2835 | 1306 | 1.62 / 429.17 | 2 | 3 |
4 | 13 | 1600.40 | 19 | 14.83 | 2351 | 662 | 2.28 / 429.84 | 2 | 3 |
5 | 13 | 1042.88 | 19 | 14.88 | 1653 | 467 | 2.75 / 430.30 | 2 | 4 |
6 | 13 | 332.52 | 19 | 15.01 | 730 | 208 | 2.96 / 430.51 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.05 | 265 | 718 | 3.67 / 431.23 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 34 | 15.01 | 430 | 219 | 0.22 / 424.03 | 2 | 2 |
2 | 12 | 1266.84 | 3 | 15.18 | 2011 | 92 | 0.31 / 424.12 | 2 | 2 |
3 | 7 | 2005.52 | 31 | 14.84 | 2828 | 1301 | 1.61 / 425.42 | 2 | 3 |
4 | 13 | 1603.48 | 19 | 14.83 | 2349 | 662 | 2.27 / 426.08 | 2 | 4 |
5 | 13 | 1161.84 | 19 | 14.85 | 1805 | 509 | 2.78 / 426.59 | 2 | 4 |
6 | 13 | 433.08 | 19 | 14.99 | 856 | 244 | 3.03 / 426.83 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.05 | 267 | 723 | 3.75 / 427.56 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 34 | 15.00 | 413 | 211 | 0.21 / 420.21 | 2 | 2 |
2 | 12 | 1264.32 | 3 | 15.21 | 1996 | 91 | 0.30 / 420.30 | 2 | 2 |
3 | 7 | 2002.56 | 31 | 14.87 | 2826 | 1303 | 1.60 / 421.60 | 2 | 3 |
4 | 13 | 1600.92 | 19 | 14.84 | 2347 | 662 | 2.27 / 422.26 | 2 | 3 |
5 | 13 | 1164.20 | 19 | 14.87 | 1806 | 510 | 2.78 / 422.77 | 2 | 4 |
6 | 13 | 423.92 | 19 | 15.01 | 846 | 241 | 3.02 / 423.01 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.06 | 263 | 713 | 3.73 / 423.73 | 2 | 10 |
8 | 14 | 0.24 | 20 | 15.03 | 269 | 81 | 3.81 / 423.81 | 2 | 6 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 34 | 15.01 | 429 | 219 | 0.22 / 416.45 | 2 | 2 |
2 | 12 | 1257.56 | 3 | 15.21 | 1987 | 91 | 0.31 / 416.54 | 2 | 2 |
3 | 7 | 2004.84 | 31 | 14.84 | 2827 | 1301 | 1.61 / 417.84 | 2 | 3 |
4 | 13 | 1590.08 | 19 | 14.84 | 2329 | 657 | 2.27 / 418.50 | 2 | 3 |
5 | 13 | 1026.80 | 19 | 14.89 | 1632 | 462 | 2.73 / 418.96 | 2 | 3 |
6 | 13 | 420.80 | 19 | 14.99 | 842 | 240 | 2.97 / 419.20 | 2 | 4 |
7 | 8 | 0.12 | 180 | 15.05 | 265 | 718 | 3.69 / 419.91 | 2 | 8 |
8 | 14 | 0.12 | 20 | 15.03 | 269 | 81 | 3.77 / 420.00 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 34 | 15.00 | 430 | 219 | 0.22 / 412.73 | 2 | 2 |
2 | 12 | 1260.56 | 3 | 15.20 | 1998 | 91 | 0.31 / 412.82 | 2 | 2 |
3 | 7 | 2005.52 | 31 | 14.85 | 2839 | 1307 | 1.62 / 414.13 | 2 | 4 |
4 | 13 | 1597.28 | 19 | 14.84 | 2342 | 660 | 2.28 / 414.79 | 2 | 3 |
5 | 13 | 1035.12 | 19 | 14.89 | 1647 | 466 | 2.74 / 415.25 | 2 | 4 |
6 | 13 | 462.88 | 19 | 14.99 | 894 | 255 | 3.00 / 415.51 | 2 | 3 |
7 | 8 | -0.08 | 180 | 15.05 | 266 | 721 | 3.72 / 416.23 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 34 | 15.02 | 423 | 216 | 0.22 / 409.08 | 2 | 3 |
2 | 12 | 1259.00 | 3 | 15.20 | 2003 | 91 | 0.31 / 409.17 | 2 | 2 |
3 | 7 | 2005.92 | 31 | 14.84 | 2833 | 1303 | 1.61 / 410.47 | 2 | 3 |
4 | 13 | 1582.40 | 19 | 14.84 | 2323 | 655 | 2.27 / 411.13 | 2 | 3 |
5 | 13 | 1013.72 | 19 | 14.89 | 1622 | 459 | 2.72 / 411.59 | 2 | 4 |
6 | 13 | 299.72 | 19 | 15.02 | 688 | 196 | 2.92 / 411.78 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.05 | 268 | 726 | 3.65 / 412.51 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 34 | 15.02 | 426 | 218 | 0.22 / 405.36 | 2 | 2 |
2 | 12 | 1255.88 | 3 | 15.21 | 1995 | 91 | 0.31 / 405.45 | 2 | 2 |
3 | 7 | 2006.08 | 31 | 14.86 | 2830 | 1304 | 1.61 / 406.75 | 2 | 3 |
4 | 13 | 1581.12 | 19 | 14.85 | 2323 | 655 | 2.27 / 407.41 | 2 | 5 |
5 | 13 | 1021.64 | 19 | 14.89 | 1629 | 461 | 2.73 / 407.87 | 2 | 4 |
6 | 13 | 311.04 | 19 | 15.03 | 698 | 199 | 2.93 / 408.07 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.06 | 263 | 713 | 3.64 / 408.78 | 2 | 6 |
8 | 14 | 0.04 | 20 | 15.04 | 265 | 80 | 3.72 / 408.86 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 34 | 15.01 | 427 | 218 | 0.22 / 401.71 | 2 | 2 |
2 | 12 | 1255.60 | 3 | 15.18 | 2006 | 91 | 0.31 / 401.80 | 2 | 2 |
3 | 7 | 2006.92 | 31 | 14.85 | 2839 | 1307 | 1.62 / 403.11 | 2 | 3 |
4 | 13 | 1586.32 | 19 | 14.84 | 2331 | 657 | 2.27 / 403.76 | 2 | 3 |
5 | 13 | 1023.28 | 19 | 14.89 | 1634 | 462 | 2.74 / 404.22 | 2 | 4 |
6 | 13 | 313.20 | 19 | 15.02 | 698 | 199 | 2.93 / 404.42 | 2 | 3 |
7 | 8 | 0.32 | 180 | 15.06 | 265 | 718 | 3.65 / 405.14 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 34 | 15.03 | 442 | 226 | 0.23 / 397.81 | 2 | 2 |
2 | 12 | 1260.16 | 3 | 15.21 | 2012 | 92 | 0.32 / 397.90 | 2 | 2 |
3 | 7 | 2008.76 | 32 | 14.84 | 2830 | 1344 | 1.66 / 399.25 | 2 | 3 |
4 | 13 | 1589.64 | 19 | 14.84 | 2329 | 657 | 2.32 / 399.91 | 2 | 4 |
5 | 13 | 1015.64 | 19 | 14.90 | 1616 | 457 | 2.78 / 400.36 | 2 | 5 |
6 | 13 | 432.76 | 19 | 15.00 | 863 | 246 | 3.02 / 400.61 | 2 | 3 |
7 | 13 | 20.16 | 19 | 15.09 | 305 | 87 | 3.11 / 400.70 | 2 | 3 |
8 | 8 | -0.16 | 180 | 15.05 | 263 | 712 | 3.82 / 401.41 | 2 | 13 |
9 | 14 | -0.16 | 20 | 15.03 | 268 | 81 | 3.90 / 401.49 | 4 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 34 | 15.02 | 414 | 211 | 0.21 / 394.08 | 2 | 2 |
2 | 12 | 1262.48 | 3 | 15.21 | 2007 | 92 | 0.30 / 394.17 | 2 | 2 |
3 | 7 | 2003.24 | 31 | 14.86 | 2827 | 1302 | 1.61 / 395.48 | 2 | 3 |
4 | 13 | 1586.04 | 19 | 14.85 | 2331 | 658 | 2.26 / 396.13 | 2 | 4 |
5 | 13 | 1137.80 | 19 | 14.88 | 1776 | 502 | 2.77 / 396.64 | 2 | 5 |
6 | 13 | 393.44 | 19 | 15.01 | 815 | 232 | 3.00 / 396.87 | 2 | 4 |
7 | 8 | 0.24 | 180 | 15.07 | 265 | 719 | 3.72 / 397.59 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 34 | 15.03 | 425 | 217 | 0.22 / 390.37 | 2 | 2 |
2 | 12 | 1257.96 | 3 | 15.20 | 2000 | 91 | 0.31 / 390.46 | 2 | 2 |
3 | 7 | 2003.60 | 31 | 14.85 | 2830 | 1303 | 1.61 / 391.76 | 2 | 3 |
4 | 13 | 1589.24 | 19 | 14.84 | 2326 | 656 | 2.27 / 392.42 | 2 | 5 |
5 | 13 | 1015.00 | 19 | 14.89 | 1622 | 459 | 2.73 / 392.88 | 2 | 5 |
6 | 13 | 305.92 | 19 | 15.03 | 690 | 197 | 2.92 / 393.07 | 2 | 3 |
7 | 8 | -0.08 | 180 | 15.06 | 264 | 716 | 3.64 / 393.79 | 2 | 9 |
8 | 14 | -0.08 | 20 | 15.05 | 266 | 80 | 3.72 / 393.87 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 34 | 15.03 | 436 | 223 | 0.22 / 386.73 | 2 | 2 |
2 | 12 | 1252.84 | 3 | 15.21 | 1990 | 91 | 0.31 / 386.82 | 2 | 2 |
3 | 7 | 2003.80 | 31 | 14.87 | 2829 | 1304 | 1.62 / 388.12 | 2 | 4 |
4 | 13 | 1577.76 | 19 | 14.86 | 2318 | 654 | 2.27 / 388.78 | 2 | 4 |
5 | 13 | 1022.24 | 19 | 14.90 | 1628 | 461 | 2.73 / 389.24 | 2 | 5 |
6 | 13 | 311.32 | 19 | 15.04 | 706 | 202 | 2.93 / 389.44 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.06 | 263 | 713 | 3.65 / 390.15 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 34 | 15.02 | 431 | 220 | 0.22 / 383.04 | 2 | 2 |
2 | 12 | 1249.72 | 3 | 15.22 | 1971 | 90 | 0.31 / 383.13 | 2 | 2 |
3 | 7 | 2008.60 | 31 | 14.86 | 2833 | 1305 | 1.62 / 384.43 | 2 | 3 |
4 | 13 | 1578.56 | 19 | 14.86 | 2322 | 656 | 2.27 / 385.09 | 2 | 4 |
5 | 13 | 1014.04 | 19 | 14.90 | 1619 | 458 | 2.73 / 385.55 | 2 | 4 |
6 | 13 | 441.48 | 19 | 15.00 | 873 | 249 | 2.98 / 385.79 | 2 | 4 |
7 | 8 | 0.08 | 180 | 15.06 | 262 | 710 | 3.69 / 386.50 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 34 | 15.01 | 433 | 221 | 0.22 / 379.25 | 2 | 2 |
2 | 12 | 1262.40 | 3 | 15.20 | 1990 | 91 | 0.31 / 379.34 | 2 | 2 |
3 | 7 | 2008.96 | 31 | 14.86 | 2827 | 1302 | 1.61 / 380.64 | 2 | 3 |
4 | 13 | 1597.04 | 19 | 14.85 | 2345 | 662 | 2.28 / 381.30 | 2 | 3 |
5 | 13 | 1035.88 | 19 | 14.89 | 1643 | 465 | 2.74 / 381.77 | 2 | 4 |
6 | 13 | 445.96 | 19 | 15.00 | 880 | 251 | 2.99 / 382.02 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.06 | 264 | 716 | 3.71 / 382.74 | 2 | 11 |
8 | 14 | 0.20 | 20 | 15.05 | 267 | 80 | 3.79 / 382.82 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 33 | 15.01 | 431 | 213 | 0.21 / 375.36 | 2 | 2 |
2 | 12 | 1246.44 | 3 | 15.21 | 1978 | 90 | 0.30 / 375.45 | 2 | 2 |
3 | 7 | 2006.40 | 32 | 14.85 | 2829 | 1344 | 1.65 / 376.80 | 2 | 3 |
4 | 13 | 1590.36 | 19 | 14.85 | 2340 | 660 | 2.31 / 377.46 | 2 | 3 |
5 | 13 | 1146.64 | 19 | 14.87 | 1795 | 507 | 2.82 / 377.96 | 2 | 6 |
6 | 13 | 389.96 | 19 | 15.01 | 803 | 229 | 3.04 / 378.19 | 2 | 3 |
7 | 13 | 116.72 | 19 | 15.06 | 441 | 126 | 3.17 / 378.32 | 2 | 3 |
8 | 8 | 0.04 | 180 | 15.04 | 262 | 709 | 3.88 / 379.03 | 2 | 9 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 33 | 15.02 | 433 | 215 | 0.21 / 371.70 | 2 | 2 |
2 | 12 | 1257.20 | 3 | 15.22 | 2010 | 92 | 0.31 / 371.79 | 2 | 2 |
3 | 7 | 2004.00 | 31 | 14.87 | 2827 | 1303 | 1.61 / 373.10 | 2 | 4 |
4 | 13 | 1590.60 | 19 | 14.85 | 2332 | 658 | 2.27 / 373.76 | 2 | 4 |
5 | 13 | 1037.96 | 19 | 14.89 | 1647 | 466 | 2.73 / 374.22 | 2 | 5 |
6 | 13 | 337.12 | 19 | 15.02 | 732 | 209 | 2.94 / 374.43 | 2 | 3 |
7 | 8 | 0.28 | 180 | 15.06 | 265 | 718 | 3.66 / 375.15 | 2 | 6 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 33 | 15.01 | 430 | 213 | 0.21 / 367.94 | 2 | 2 |
2 | 12 | 1270.00 | 3 | 15.22 | 2019 | 92 | 0.31 / 368.03 | 2 | 2 |
3 | 7 | 2008.40 | 31 | 14.87 | 2837 | 1308 | 1.61 / 369.34 | 2 | 4 |
4 | 13 | 1604.68 | 19 | 14.85 | 2345 | 662 | 2.27 / 370.00 | 2 | 4 |
5 | 13 | 1041.92 | 19 | 14.90 | 1655 | 469 | 2.74 / 370.47 | 2 | 3 |
6 | 13 | 335.80 | 19 | 15.04 | 736 | 210 | 2.95 / 370.68 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.07 | 268 | 727 | 3.68 / 371.41 | 2 | 8 |
8 | 14 | 0.24 | 20 | 15.05 | 271 | 82 | 3.76 / 371.49 | 3 | 6 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 33 | 15.03 | 427 | 212 | 0.21 / 364.16 | 2 | 2 |
2 | 12 | 1264.20 | 3 | 15.21 | 2006 | 92 | 0.30 / 364.25 | 2 | 2 |
3 | 7 | 2008.04 | 31 | 14.85 | 2831 | 1303 | 1.61 / 365.55 | 2 | 4 |
4 | 13 | 1592.04 | 19 | 14.84 | 2340 | 660 | 2.27 / 366.21 | 2 | 4 |
5 | 13 | 1019.16 | 19 | 14.89 | 1628 | 461 | 2.73 / 366.67 | 2 | 5 |
6 | 13 | 435.88 | 19 | 14.99 | 868 | 247 | 2.97 / 366.92 | 2 | 3 |
7 | 13 | 20.96 | 19 | 15.08 | 306 | 88 | 3.06 / 367.01 | 2 | 3 |
8 | 8 | -0.16 | 180 | 15.05 | 266 | 721 | 3.78 / 367.73 | 2 | 10 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 33 | 15.02 | 433 | 215 | 0.21 / 360.41 | 2 | 2 |
2 | 12 | 1262.20 | 3 | 15.20 | 1989 | 91 | 0.31 / 360.50 | 2 | 2 |
3 | 7 | 2008.08 | 31 | 14.88 | 2833 | 1307 | 1.61 / 361.80 | 2 | 4 |
4 | 13 | 1599.04 | 19 | 14.85 | 2344 | 661 | 2.27 / 362.46 | 2 | 4 |
5 | 13 | 1157.00 | 19 | 14.87 | 1807 | 511 | 2.78 / 362.98 | 2 | 5 |
6 | 13 | 424.72 | 19 | 15.02 | 846 | 241 | 3.03 / 363.22 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.07 | 268 | 727 | 3.75 / 363.94 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 33 | 15.02 | 436 | 216 | 0.22 / 356.71 | 2 | 2 |
2 | 12 | 1256.88 | 3 | 15.22 | 2007 | 92 | 0.31 / 356.80 | 2 | 2 |
3 | 7 | 2005.60 | 31 | 14.86 | 2834 | 1306 | 1.61 / 358.10 | 2 | 4 |
4 | 13 | 1581.76 | 19 | 14.86 | 2325 | 656 | 2.27 / 358.76 | 2 | 4 |
5 | 13 | 1018.00 | 19 | 14.90 | 1632 | 462 | 2.73 / 359.22 | 2 | 5 |
6 | 13 | 425.20 | 19 | 15.02 | 851 | 243 | 2.97 / 359.46 | 2 | 4 |
7 | 8 | 0.08 | 180 | 15.07 | 268 | 727 | 3.70 / 360.19 | 2 | 7 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 33 | 15.02 | 423 | 210 | 0.21 / 353.04 | 2 | 2 |
2 | 12 | 1251.40 | 3 | 15.21 | 1994 | 91 | 0.30 / 353.13 | 2 | 2 |
3 | 7 | 2006.28 | 31 | 14.86 | 2819 | 1299 | 1.60 / 354.43 | 2 | 3 |
4 | 13 | 1595.40 | 19 | 14.86 | 2339 | 660 | 2.26 / 355.09 | 2 | 4 |
5 | 13 | 1030.04 | 19 | 14.90 | 1647 | 466 | 2.73 / 355.56 | 2 | 5 |
6 | 13 | 323.52 | 19 | 15.03 | 721 | 206 | 2.93 / 355.76 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.07 | 268 | 727 | 3.66 / 356.49 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 33 | 15.04 | 427 | 212 | 0.21 / 349.41 | 2 | 2 |
2 | 12 | 1251.68 | 3 | 15.22 | 1983 | 91 | 0.30 / 349.50 | 2 | 2 |
3 | 7 | 2003.04 | 31 | 14.86 | 2823 | 1300 | 1.60 / 350.80 | 2 | 3 |
4 | 13 | 1576.76 | 19 | 14.85 | 2312 | 652 | 2.26 / 351.45 | 2 | 4 |
5 | 13 | 1013.32 | 19 | 14.91 | 1618 | 458 | 2.71 / 351.91 | 2 | 4 |
6 | 13 | 306.80 | 19 | 15.05 | 694 | 198 | 2.91 / 352.11 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.08 | 267 | 725 | 3.64 / 352.83 | 2 | 9 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 33 | 15.04 | 431 | 214 | 0.21 / 345.68 | 2 | 3 |
2 | 12 | 1259.16 | 3 | 15.22 | 2013 | 92 | 0.31 / 345.78 | 2 | 2 |
3 | 7 | 2003.44 | 31 | 14.88 | 2826 | 1304 | 1.61 / 347.08 | 2 | 3 |
4 | 13 | 1599.32 | 19 | 14.86 | 2347 | 663 | 2.27 / 347.74 | 2 | 6 |
5 | 13 | 1039.84 | 19 | 14.91 | 1661 | 471 | 2.74 / 348.21 | 2 | 4 |
6 | 13 | 447.20 | 19 | 15.02 | 880 | 251 | 2.99 / 348.46 | 2 | 4 |
7 | 8 | 0.12 | 180 | 15.08 | 269 | 730 | 3.72 / 349.19 | 2 | 9 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 33 | 15.03 | 433 | 215 | 0.21 / 342.02 | 2 | 2 |
2 | 12 | 1256.32 | 3 | 15.23 | 1994 | 91 | 0.31 / 342.11 | 2 | 2 |
3 | 7 | 2006.08 | 31 | 14.87 | 2827 | 1303 | 1.61 / 343.42 | 2 | 3 |
4 | 13 | 1585.00 | 19 | 14.87 | 2335 | 660 | 2.27 / 344.08 | 2 | 4 |
5 | 13 | 1019.04 | 19 | 14.92 | 1630 | 462 | 2.73 / 344.54 | 2 | 4 |
6 | 13 | 307.40 | 19 | 15.06 | 701 | 201 | 2.93 / 344.74 | 2 | 4 |
7 | 8 | 0.08 | 180 | 15.08 | 269 | 730 | 3.66 / 345.47 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 33 | 15.04 | 432 | 214 | 0.21 / 338.31 | 2 | 2 |
2 | 12 | 1261.40 | 3 | 15.21 | 2003 | 91 | 0.31 / 338.40 | 2 | 2 |
3 | 7 | 2005.08 | 31 | 14.87 | 2831 | 1305 | 1.61 / 339.71 | 2 | 4 |
4 | 13 | 1585.16 | 19 | 14.86 | 2326 | 657 | 2.27 / 340.36 | 2 | 4 |
5 | 13 | 1019.76 | 19 | 14.92 | 1625 | 461 | 2.73 / 340.82 | 2 | 4 |
6 | 13 | 428.84 | 19 | 15.02 | 857 | 245 | 2.97 / 341.07 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.07 | 273 | 741 | 3.71 / 341.81 | 2 | 8 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 33 | 15.04 | 427 | 212 | 0.21 / 334.58 | 2 | 2 |
2 | 12 | 1256.84 | 3 | 15.22 | 1996 | 91 | 0.30 / 334.67 | 2 | 2 |
3 | 7 | 2005.08 | 31 | 14.87 | 2840 | 1309 | 1.61 / 335.98 | 2 | 3 |
4 | 13 | 1584.28 | 19 | 14.88 | 2329 | 658 | 2.27 / 336.64 | 2 | 3 |
5 | 13 | 1133.88 | 19 | 14.90 | 1775 | 503 | 2.77 / 337.14 | 2 | 5 |
6 | 13 | 392.56 | 19 | 15.04 | 804 | 230 | 3.00 / 337.37 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.09 | 267 | 725 | 3.73 / 338.10 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 33 | 15.04 | 430 | 213 | 0.21 / 330.85 | 2 | 2 |
2 | 12 | 1258.80 | 3 | 15.23 | 2001 | 91 | 0.30 / 330.94 | 2 | 2 |
3 | 7 | 2007.80 | 31 | 14.88 | 2833 | 1307 | 1.61 / 332.24 | 2 | 3 |
4 | 13 | 1588.64 | 19 | 14.86 | 2341 | 661 | 2.27 / 332.90 | 2 | 3 |
5 | 13 | 1013.16 | 19 | 14.92 | 1620 | 459 | 2.73 / 333.36 | 2 | 5 |
6 | 13 | 292.44 | 19 | 15.06 | 681 | 195 | 2.93 / 333.56 | 2 | 3 |
7 | 8 | -0.08 | 180 | 15.08 | 268 | 727 | 3.65 / 334.29 | 2 | 8 |
8 | 14 | -0.08 | 20 | 15.06 | 269 | 81 | 3.74 / 334.37 | 3 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 33 | 15.05 | 426 | 212 | 0.21 / 327.14 | 2 | 2 |
2 | 12 | 1252.24 | 3 | 15.24 | 2000 | 91 | 0.30 / 327.23 | 2 | 2 |
3 | 7 | 2007.16 | 31 | 14.88 | 2835 | 1308 | 1.61 / 328.54 | 2 | 4 |
4 | 13 | 1589.24 | 19 | 14.88 | 2334 | 660 | 2.27 / 329.20 | 2 | 4 |
5 | 13 | 1018.28 | 19 | 14.93 | 1627 | 462 | 2.73 / 329.66 | 2 | 5 |
6 | 13 | 425.24 | 19 | 15.03 | 857 | 245 | 2.98 / 329.90 | 2 | 4 |
7 | 8 | 0.20 | 180 | 15.08 | 268 | 727 | 3.70 / 330.63 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 33 | 15.05 | 423 | 210 | 0.21 / 323.43 | 2 | 2 |
2 | 12 | 1261.08 | 3 | 15.23 | 1998 | 91 | 0.30 / 323.52 | 2 | 2 |
3 | 7 | 2007.28 | 31 | 14.87 | 2838 | 1308 | 1.61 / 324.83 | 2 | 3 |
4 | 13 | 1584.32 | 19 | 14.88 | 2331 | 659 | 2.27 / 325.49 | 2 | 4 |
5 | 13 | 1011.48 | 19 | 14.93 | 1623 | 460 | 2.73 / 325.95 | 2 | 5 |
6 | 13 | 420.68 | 19 | 15.03 | 847 | 242 | 2.97 / 326.19 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.09 | 270 | 733 | 3.70 / 326.93 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 33 | 15.05 | 418 | 208 | 0.21 / 319.79 | 2 | 2 |
2 | 12 | 1261.96 | 3 | 15.23 | 2013 | 92 | 0.30 / 319.89 | 2 | 2 |
3 | 7 | 2008.40 | 31 | 14.87 | 2832 | 1305 | 1.61 / 321.19 | 2 | 3 |
4 | 13 | 1584.04 | 19 | 14.87 | 2332 | 659 | 2.26 / 321.85 | 2 | 4 |
5 | 13 | 1005.72 | 19 | 14.93 | 1613 | 458 | 2.72 / 322.31 | 2 | 4 |
6 | 13 | 297.52 | 19 | 15.07 | 686 | 196 | 2.92 / 322.50 | 2 | 3 |
7 | 8 | -0.04 | 180 | 15.09 | 265 | 720 | 3.64 / 323.22 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.08 | 425 | 211 | 0.21 / 316.15 | 2 | 2 |
2 | 12 | 1252.00 | 3 | 15.22 | 1987 | 91 | 0.30 / 316.24 | 2 | 2 |
3 | 7 | 2007.08 | 31 | 14.88 | 2833 | 1307 | 1.61 / 317.54 | 2 | 4 |
4 | 13 | 1586.96 | 19 | 14.88 | 2333 | 660 | 2.27 / 318.20 | 2 | 5 |
5 | 13 | 1017.60 | 19 | 14.93 | 1631 | 463 | 2.73 / 318.67 | 2 | 6 |
6 | 13 | 308.20 | 19 | 15.07 | 703 | 201 | 2.93 / 318.87 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.10 | 264 | 718 | 3.65 / 319.59 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.07 | 430 | 214 | 0.21 / 312.50 | 2 | 2 |
2 | 12 | 1253.52 | 3 | 15.24 | 1991 | 91 | 0.30 / 312.59 | 2 | 2 |
3 | 7 | 2004.32 | 31 | 14.89 | 2840 | 1311 | 1.62 / 313.90 | 2 | 3 |
4 | 13 | 1582.28 | 19 | 14.89 | 2331 | 659 | 2.28 / 314.56 | 2 | 4 |
5 | 13 | 1009.88 | 19 | 14.95 | 1619 | 460 | 2.74 / 315.02 | 2 | 4 |
6 | 13 | 294.36 | 19 | 15.09 | 677 | 194 | 2.93 / 315.22 | 2 | 3 |
7 | 8 | 0.28 | 180 | 15.11 | 264 | 718 | 3.65 / 315.94 | 2 | 8 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 33 | 15.07 | 435 | 216 | 0.22 / 308.78 | 2 | 2 |
2 | 12 | 1252.96 | 3 | 15.24 | 1995 | 91 | 0.31 / 308.88 | 2 | 2 |
3 | 7 | 2003.76 | 32 | 14.89 | 2821 | 1344 | 1.65 / 310.22 | 2 | 3 |
4 | 13 | 1580.56 | 19 | 14.89 | 2324 | 657 | 2.31 / 310.88 | 2 | 3 |
5 | 13 | 1008.24 | 19 | 14.95 | 1612 | 458 | 2.77 / 311.34 | 2 | 4 |
6 | 13 | 417.08 | 19 | 15.06 | 841 | 241 | 3.01 / 311.58 | 2 | 4 |
7 | 8 | -0.08 | 180 | 15.11 | 262 | 713 | 3.72 / 312.29 | 2 | 7 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 33 | 15.08 | 431 | 214 | 0.21 / 305.06 | 2 | 2 |
2 | 12 | 1241.44 | 3 | 15.25 | 1966 | 90 | 0.30 / 305.15 | 2 | 2 |
3 | 7 | 2003.80 | 31 | 14.90 | 2831 | 1308 | 1.61 / 306.46 | 2 | 3 |
4 | 13 | 1594.24 | 19 | 14.89 | 2341 | 662 | 2.27 / 307.12 | 2 | 4 |
5 | 13 | 1025.84 | 19 | 14.94 | 1634 | 464 | 2.74 / 307.58 | 2 | 5 |
6 | 13 | 444.44 | 19 | 15.05 | 880 | 252 | 2.99 / 307.84 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.11 | 269 | 732 | 3.72 / 308.57 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 33 | 15.08 | 421 | 210 | 0.21 / 301.39 | 2 | 2 |
2 | 12 | 1258.88 | 3 | 15.25 | 2020 | 92 | 0.30 / 301.48 | 2 | 2 |
3 | 7 | 2008.16 | 31 | 14.89 | 2830 | 1306 | 1.61 / 302.79 | 2 | 3 |
4 | 13 | 1588.04 | 19 | 14.89 | 2340 | 662 | 2.27 / 303.45 | 2 | 4 |
5 | 13 | 1021.36 | 19 | 14.95 | 1636 | 465 | 2.73 / 303.92 | 2 | 3 |
6 | 13 | 305.76 | 19 | 15.09 | 699 | 200 | 2.94 / 304.12 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.12 | 268 | 729 | 3.66 / 304.85 | 2 | 7 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 33 | 15.08 | 436 | 217 | 0.22 / 297.60 | 2 | 2 |
2 | 12 | 1249.16 | 3 | 15.25 | 1979 | 91 | 0.31 / 297.69 | 2 | 2 |
3 | 7 | 2005.72 | 31 | 14.89 | 2836 | 1309 | 1.62 / 299.00 | 2 | 3 |
4 | 13 | 1593.64 | 19 | 14.88 | 2344 | 663 | 2.28 / 299.66 | 2 | 4 |
5 | 13 | 1018.20 | 19 | 14.95 | 1625 | 462 | 2.74 / 300.12 | 2 | 5 |
6 | 13 | 432.12 | 19 | 15.06 | 865 | 248 | 2.99 / 300.37 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.12 | 269 | 732 | 3.72 / 301.10 | 2 | 6 |
8 | 14 | 0.08 | 20 | 15.10 | 271 | 82 | 3.80 / 301.18 | 2 | 3 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 15.09 | 435 | 217 | 0.22 / 293.92 | 2 | 2 |
2 | 12 | 1252.00 | 3 | 15.25 | 2011 | 92 | 0.31 / 294.01 | 2 | 2 |
3 | 7 | 2004.72 | 31 | 14.89 | 2832 | 1307 | 1.62 / 295.32 | 2 | 4 |
4 | 13 | 1588.96 | 19 | 14.90 | 2339 | 662 | 2.28 / 295.98 | 2 | 5 |
5 | 13 | 1013.92 | 19 | 14.95 | 1626 | 462 | 2.74 / 296.44 | 2 | 4 |
6 | 13 | 309.80 | 19 | 15.10 | 702 | 201 | 2.94 / 296.64 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.12 | 271 | 738 | 3.68 / 297.38 | 2 | 8 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 33 | 15.09 | 438 | 218 | 0.22 / 290.23 | 2 | 2 |
2 | 12 | 1261.92 | 3 | 15.25 | 1998 | 91 | 0.31 / 290.32 | 2 | 2 |
3 | 7 | 2005.96 | 31 | 14.90 | 2842 | 1313 | 1.62 / 291.64 | 2 | 3 |
4 | 13 | 1590.60 | 19 | 14.89 | 2335 | 661 | 2.28 / 292.30 | 2 | 5 |
5 | 13 | 1027.48 | 19 | 14.94 | 1640 | 466 | 2.75 / 292.76 | 2 | 5 |
6 | 13 | 323.76 | 19 | 15.09 | 721 | 207 | 2.96 / 292.97 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.12 | 269 | 732 | 3.69 / 293.70 | 2 | 7 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 15.10 | 432 | 215 | 0.22 / 286.56 | 2 | 2 |
2 | 12 | 1249.32 | 3 | 15.26 | 1991 | 91 | 0.31 / 286.65 | 2 | 2 |
3 | 7 | 2009.44 | 31 | 14.90 | 2838 | 1311 | 1.62 / 287.96 | 2 | 4 |
4 | 13 | 1584.28 | 19 | 14.90 | 2334 | 661 | 2.28 / 288.62 | 2 | 3 |
5 | 13 | 1011.04 | 19 | 14.96 | 1618 | 460 | 2.74 / 289.08 | 2 | 5 |
6 | 13 | 296.84 | 19 | 15.11 | 688 | 198 | 2.94 / 289.28 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.13 | 271 | 738 | 3.67 / 290.01 | 2 | 9 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.16 | 33 | 15.10 | 444 | 221 | 0.22 / 282.75 | 2 | 2 |
2 | 12 | 1250.92 | 3 | 15.26 | 1983 | 91 | 0.31 / 282.85 | 2 | 2 |
3 | 7 | 2005.84 | 31 | 14.90 | 2836 | 1310 | 1.62 / 284.16 | 2 | 4 |
4 | 13 | 1585.12 | 19 | 14.90 | 2335 | 661 | 2.28 / 284.82 | 2 | 3 |
5 | 13 | 1008.92 | 19 | 14.96 | 1618 | 460 | 2.74 / 285.28 | 2 | 4 |
6 | 13 | 413.04 | 19 | 15.08 | 841 | 241 | 2.98 / 285.52 | 2 | 3 |
7 | 13 | 14.72 | 19 | 15.17 | 303 | 87 | 3.07 / 285.60 | 2 | 3 |
8 | 8 | 0.16 | 180 | 15.13 | 270 | 735 | 3.81 / 286.34 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 33 | 15.11 | 430 | 214 | 0.21 / 278.92 | 2 | 2 |
2 | 12 | 1244.76 | 3 | 15.25 | 1987 | 91 | 0.31 / 279.01 | 2 | 2 |
3 | 7 | 2003.40 | 31 | 14.90 | 2830 | 1307 | 1.61 / 280.32 | 2 | 3 |
4 | 13 | 1581.76 | 19 | 14.90 | 2325 | 658 | 2.27 / 280.98 | 2 | 4 |
5 | 13 | 1010.60 | 19 | 14.97 | 1618 | 460 | 2.73 / 281.44 | 2 | 5 |
6 | 13 | 284.12 | 19 | 15.11 | 667 | 191 | 2.92 / 281.63 | 2 | 3 |
7 | 13 | 25.28 | 19 | 15.17 | 314 | 91 | 3.01 / 281.72 | 2 | 3 |
8 | 8 | -0.24 | 180 | 15.13 | 268 | 730 | 3.74 / 282.45 | 2 | 8 |
9 | 14 | -0.24 | 20 | 15.12 | 269 | 81 | 3.82 / 282.53 | 2 | 10 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 33 | 15.11 | 426 | 212 | 0.21 / 275.27 | 2 | 3 |
2 | 12 | 1249.12 | 3 | 15.26 | 1986 | 91 | 0.30 / 275.36 | 2 | 2 |
3 | 7 | 2003.08 | 31 | 14.90 | 2835 | 1309 | 1.61 / 276.67 | 2 | 4 |
4 | 13 | 1583.92 | 19 | 14.91 | 2332 | 661 | 2.27 / 277.33 | 2 | 5 |
5 | 13 | 1003.88 | 19 | 14.97 | 1607 | 457 | 2.73 / 277.78 | 2 | 3 |
6 | 13 | 289.56 | 19 | 15.12 | 675 | 194 | 2.92 / 277.98 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.15 | 268 | 731 | 3.66 / 278.71 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 33 | 15.10 | 423 | 211 | 0.21 / 271.60 | 2 | 2 |
2 | 12 | 1255.60 | 3 | 15.25 | 2006 | 92 | 0.30 / 271.69 | 2 | 2 |
3 | 7 | 2005.80 | 31 | 14.91 | 2832 | 1309 | 1.61 / 273.00 | 2 | 3 |
4 | 13 | 1581.80 | 19 | 14.90 | 2331 | 660 | 2.27 / 273.66 | 2 | 5 |
5 | 13 | 1008.96 | 19 | 14.96 | 1617 | 460 | 2.73 / 274.12 | 2 | 4 |
6 | 13 | 303.20 | 19 | 15.12 | 697 | 200 | 2.93 / 274.32 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.14 | 269 | 733 | 3.66 / 275.05 | 2 | 9 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 33 | 15.11 | 419 | 209 | 0.21 / 267.97 | 2 | 2 |
2 | 12 | 1274.28 | 3 | 15.25 | 2033 | 93 | 0.30 / 268.06 | 2 | 2 |
3 | 7 | 2005.64 | 31 | 14.91 | 2830 | 1308 | 1.61 / 269.37 | 2 | 4 |
4 | 13 | 1578.00 | 19 | 14.90 | 2328 | 659 | 2.27 / 270.03 | 2 | 3 |
5 | 13 | 1002.44 | 19 | 14.97 | 1609 | 458 | 2.73 / 270.48 | 2 | 4 |
6 | 13 | 283.20 | 19 | 15.13 | 664 | 191 | 2.92 / 270.68 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.15 | 262 | 714 | 3.63 / 271.39 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 33 | 15.11 | 420 | 209 | 0.21 / 264.17 | 2 | 2 |
2 | 12 | 1255.72 | 3 | 15.27 | 2004 | 92 | 0.30 / 264.26 | 2 | 2 |
3 | 7 | 2003.92 | 31 | 14.92 | 2835 | 1311 | 1.61 / 265.57 | 2 | 4 |
4 | 13 | 1585.84 | 19 | 14.91 | 2332 | 661 | 2.27 / 266.23 | 2 | 3 |
5 | 13 | 1017.96 | 19 | 14.97 | 1627 | 463 | 2.74 / 266.69 | 2 | 4 |
6 | 13 | 436.96 | 19 | 15.09 | 869 | 249 | 2.99 / 266.94 | 2 | 3 |
7 | 13 | 23.72 | 19 | 15.17 | 310 | 89 | 3.07 / 267.03 | 2 | 3 |
8 | 8 | 0.12 | 180 | 15.14 | 266 | 725 | 3.80 / 267.76 | 2 | 8 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 33 | 15.12 | 414 | 207 | 0.21 / 260.44 | 2 | 2 |
2 | 12 | 1252.80 | 3 | 15.25 | 1993 | 91 | 0.30 / 260.53 | 2 | 2 |
3 | 7 | 2005.80 | 31 | 14.89 | 2829 | 1306 | 1.60 / 261.84 | 2 | 4 |
4 | 13 | 1581.88 | 19 | 14.91 | 2329 | 660 | 2.26 / 262.50 | 2 | 3 |
5 | 13 | 998.04 | 19 | 14.97 | 1604 | 456 | 2.72 / 262.95 | 2 | 6 |
6 | 13 | 283.16 | 19 | 15.13 | 664 | 191 | 2.91 / 263.14 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.15 | 269 | 734 | 3.64 / 263.88 | 2 | 6 |
8 | 14 | 0.08 | 20 | 15.13 | 269 | 81 | 3.73 / 263.96 | 3 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 33 | 15.12 | 420 | 210 | 0.21 / 256.73 | 2 | 2 |
2 | 12 | 1241.44 | 3 | 15.27 | 1996 | 91 | 0.30 / 256.82 | 2 | 2 |
3 | 7 | 2002.56 | 31 | 14.91 | 2827 | 1307 | 1.61 / 258.13 | 2 | 3 |
4 | 13 | 1569.04 | 19 | 14.90 | 2314 | 655 | 2.26 / 258.78 | 2 | 5 |
5 | 13 | 988.60 | 19 | 14.98 | 1594 | 454 | 2.72 / 259.24 | 2 | 3 |
6 | 13 | 268.28 | 19 | 15.13 | 647 | 186 | 2.90 / 259.42 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.15 | 267 | 728 | 3.63 / 260.15 | 2 | 4 |
8 | 14 | 0.08 | 20 | 15.14 | 271 | 82 | 3.71 / 260.23 | 5 | 13 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 33 | 15.11 | 436 | 217 | 0.22 / 252.92 | 2 | 3 |
2 | 12 | 1242.40 | 3 | 15.27 | 1992 | 91 | 0.31 / 253.01 | 2 | 2 |
3 | 7 | 2003.64 | 31 | 14.92 | 2833 | 1310 | 1.62 / 254.32 | 2 | 4 |
4 | 13 | 1576.16 | 19 | 14.91 | 2321 | 658 | 2.28 / 254.98 | 2 | 4 |
5 | 13 | 1133.96 | 19 | 14.96 | 1777 | 505 | 2.78 / 255.48 | 2 | 7 |
6 | 13 | 374.68 | 19 | 15.12 | 789 | 227 | 3.01 / 255.71 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.16 | 267 | 729 | 3.74 / 256.44 | 2 | 5 |
8 | 14 | 0.16 | 20 | 15.14 | 269 | 81 | 3.82 / 256.52 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 33 | 15.13 | 427 | 213 | 0.21 / 249.15 | 2 | 2 |
2 | 12 | 1255.96 | 3 | 15.26 | 2009 | 92 | 0.31 / 249.24 | 2 | 2 |
3 | 7 | 2003.08 | 32 | 14.91 | 2834 | 1352 | 1.66 / 250.60 | 2 | 3 |
4 | 13 | 1583.92 | 19 | 14.91 | 2335 | 661 | 2.32 / 251.26 | 2 | 5 |
5 | 13 | 1005.16 | 19 | 14.98 | 1620 | 461 | 2.78 / 251.72 | 2 | 7 |
6 | 13 | 410.88 | 19 | 15.10 | 833 | 239 | 3.02 / 251.96 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.16 | 273 | 745 | 3.76 / 252.70 | 2 | 9 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 33 | 15.12 | 433 | 216 | 0.22 / 245.38 | 2 | 2 |
2 | 12 | 1245.76 | 3 | 15.28 | 1977 | 91 | 0.31 / 245.47 | 2 | 2 |
3 | 7 | 2003.80 | 32 | 14.92 | 2847 | 1359 | 1.67 / 246.83 | 2 | 3 |
4 | 13 | 1581.92 | 19 | 14.92 | 2333 | 661 | 2.33 / 247.50 | 2 | 5 |
5 | 13 | 1005.88 | 19 | 14.98 | 1621 | 461 | 2.79 / 247.96 | 2 | 3 |
6 | 13 | 412.76 | 19 | 15.11 | 840 | 241 | 3.03 / 248.20 | 2 | 4 |
7 | 8 | 0.08 | 180 | 15.17 | 271 | 740 | 3.77 / 248.94 | 2 | 8 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 33 | 15.13 | 418 | 209 | 0.21 / 241.75 | 2 | 2 |
2 | 12 | 1242.92 | 3 | 15.26 | 1988 | 91 | 0.30 / 241.84 | 2 | 2 |
3 | 7 | 2004.08 | 31 | 14.90 | 2839 | 1311 | 1.61 / 243.15 | 2 | 4 |
4 | 13 | 1466.48 | 19 | 14.93 | 2193 | 622 | 2.23 / 243.77 | 2 | 5 |
5 | 13 | 1040.84 | 19 | 14.98 | 1655 | 471 | 2.70 / 244.24 | 2 | 5 |
6 | 13 | 295.12 | 19 | 15.14 | 682 | 196 | 2.90 / 244.44 | 2 | 3 |
7 | 8 | 0.12 | 180 | 15.17 | 267 | 729 | 3.63 / 245.17 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 33 | 15.13 | 423 | 211 | 0.21 / 238.09 | 2 | 3 |
2 | 12 | 1252.32 | 3 | 15.28 | 2001 | 92 | 0.30 / 238.18 | 2 | 2 |
3 | 7 | 2004.84 | 31 | 14.93 | 2831 | 1310 | 1.61 / 239.49 | 2 | 5 |
4 | 13 | 1579.72 | 19 | 14.93 | 2326 | 660 | 2.27 / 240.15 | 2 | 4 |
5 | 13 | 1001.12 | 19 | 15.00 | 1610 | 459 | 2.73 / 240.61 | 2 | 4 |
6 | 13 | 287.52 | 19 | 15.16 | 678 | 195 | 2.93 / 240.80 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.17 | 269 | 735 | 3.66 / 241.54 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 33 | 15.15 | 417 | 208 | 0.21 / 234.45 | 2 | 3 |
2 | 12 | 1251.44 | 3 | 15.27 | 1997 | 91 | 0.30 / 234.54 | 2 | 2 |
3 | 7 | 2004.00 | 31 | 14.92 | 2837 | 1312 | 1.61 / 235.85 | 2 | 4 |
4 | 13 | 1465.40 | 19 | 14.95 | 2186 | 621 | 2.23 / 236.47 | 2 | 5 |
5 | 13 | 1041.20 | 19 | 14.99 | 1664 | 474 | 2.71 / 236.95 | 2 | 4 |
6 | 13 | 308.48 | 19 | 15.15 | 697 | 201 | 2.91 / 237.15 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.18 | 267 | 730 | 3.64 / 237.88 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 15.13 | 422 | 211 | 0.21 / 230.81 | 2 | 2 |
2 | 12 | 1250.84 | 3 | 15.27 | 1990 | 91 | 0.30 / 230.90 | 2 | 2 |
3 | 7 | 2003.32 | 31 | 14.92 | 2835 | 1311 | 1.61 / 232.21 | 2 | 3 |
4 | 13 | 1570.72 | 19 | 14.93 | 2317 | 657 | 2.27 / 232.87 | 2 | 4 |
5 | 13 | 1000.76 | 19 | 15.00 | 1605 | 457 | 2.73 / 233.33 | 2 | 4 |
6 | 13 | 285.84 | 19 | 15.16 | 667 | 192 | 2.92 / 233.52 | 2 | 3 |
7 | 8 | 0.28 | 180 | 15.19 | 264 | 722 | 3.64 / 234.24 | 2 | 7 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 33 | 15.15 | 415 | 207 | 0.21 / 227.16 | 2 | 2 |
2 | 12 | 1245.36 | 3 | 15.28 | 1986 | 91 | 0.30 / 227.26 | 2 | 2 |
3 | 7 | 2003.72 | 31 | 14.92 | 2827 | 1308 | 1.61 / 228.56 | 2 | 5 |
4 | 13 | 1578.96 | 19 | 14.92 | 2320 | 658 | 2.26 / 229.22 | 2 | 4 |
5 | 13 | 1004.08 | 19 | 14.99 | 1617 | 461 | 2.72 / 229.68 | 2 | 3 |
6 | 13 | 284.52 | 19 | 15.16 | 671 | 193 | 2.92 / 229.87 | 2 | 3 |
7 | 8 | 0.00 | 180 | 15.18 | 265 | 724 | 3.64 / 230.60 | 2 | 10 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 33 | 15.15 | 428 | 214 | 0.21 / 223.47 | 2 | 2 |
2 | 12 | 1244.28 | 3 | 15.29 | 2003 | 92 | 0.31 / 223.56 | 2 | 2 |
3 | 7 | 2004.72 | 31 | 14.93 | 2839 | 1314 | 1.62 / 224.87 | 2 | 3 |
4 | 13 | 1469.72 | 19 | 14.94 | 2195 | 623 | 2.24 / 225.50 | 2 | 5 |
5 | 13 | 929.88 | 19 | 15.02 | 1518 | 433 | 2.68 / 225.93 | 2 | 5 |
6 | 13 | 349.64 | 19 | 15.15 | 757 | 218 | 2.89 / 226.15 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.18 | 266 | 727 | 3.62 / 226.88 | 2 | 5 |
8 | 14 | 0.04 | 20 | 15.16 | 268 | 81 | 3.70 / 226.96 | 3 | 12 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 33 | 15.17 | 428 | 214 | 0.21 / 219.80 | 2 | 3 |
2 | 12 | 1248.60 | 3 | 15.29 | 2004 | 92 | 0.31 / 219.89 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.93 | 2836 | 1313 | 1.62 / 221.20 | 2 | 4 |
4 | 13 | 1580.76 | 19 | 14.94 | 2337 | 663 | 2.28 / 221.87 | 2 | 4 |
5 | 13 | 1000.00 | 19 | 15.01 | 1614 | 460 | 2.74 / 222.33 | 2 | 4 |
6 | 13 | 279.92 | 19 | 15.18 | 669 | 193 | 2.94 / 222.52 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.20 | 268 | 733 | 3.67 / 223.25 | 2 | 7 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 33 | 15.15 | 422 | 211 | 0.21 / 216.14 | 2 | 2 |
2 | 12 | 1253.92 | 3 | 15.28 | 2016 | 92 | 0.30 / 216.23 | 2 | 2 |
3 | 7 | 2003.60 | 31 | 14.95 | 2838 | 1315 | 1.62 / 217.55 | 2 | 4 |
4 | 13 | 1571.04 | 19 | 14.94 | 2315 | 657 | 2.28 / 218.20 | 2 | 7 |
5 | 13 | 997.20 | 19 | 15.02 | 1604 | 458 | 2.73 / 218.66 | 2 | 5 |
6 | 13 | 278.16 | 19 | 15.18 | 664 | 192 | 2.93 / 218.85 | 2 | 3 |
7 | 8 | 0.28 | 180 | 15.20 | 268 | 733 | 3.66 / 219.59 | 2 | 7 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 33 | 15.16 | 423 | 212 | 0.21 / 212.31 | 2 | 3 |
2 | 12 | 1252.24 | 3 | 15.30 | 1989 | 91 | 0.30 / 212.40 | 2 | 2 |
3 | 7 | 2006.76 | 31 | 14.95 | 2844 | 1318 | 1.62 / 213.72 | 2 | 4 |
4 | 13 | 1591.32 | 19 | 14.94 | 2347 | 666 | 2.29 / 214.38 | 2 | 4 |
5 | 13 | 1019.76 | 19 | 15.02 | 1635 | 467 | 2.75 / 214.85 | 2 | 5 |
6 | 13 | 430.76 | 19 | 15.15 | 862 | 248 | 3.00 / 215.10 | 2 | 4 |
7 | 13 | 17.92 | 19 | 15.23 | 307 | 89 | 3.09 / 215.19 | 2 | 3 |
8 | 8 | -0.24 | 180 | 15.19 | 271 | 741 | 3.83 / 215.93 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 33 | 15.16 | 422 | 211 | 0.21 / 208.67 | 2 | 2 |
2 | 12 | 1249.80 | 3 | 15.29 | 1989 | 91 | 0.30 / 208.76 | 2 | 2 |
3 | 7 | 2003.16 | 31 | 14.93 | 2832 | 1311 | 1.61 / 210.07 | 2 | 3 |
4 | 13 | 1579.32 | 19 | 14.93 | 2331 | 661 | 2.27 / 210.73 | 2 | 5 |
5 | 13 | 997.24 | 19 | 15.02 | 1594 | 455 | 2.73 / 211.18 | 2 | 6 |
6 | 13 | 278.56 | 19 | 15.18 | 660 | 190 | 2.92 / 211.37 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.20 | 264 | 722 | 3.64 / 212.10 | 2 | 4 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 33 | 15.17 | 423 | 212 | 0.21 / 205.02 | 2 | 2 |
2 | 12 | 1245.72 | 3 | 15.30 | 1992 | 91 | 0.30 / 205.11 | 2 | 2 |
3 | 7 | 2001.36 | 31 | 14.94 | 2827 | 1309 | 1.61 / 206.42 | 2 | 5 |
4 | 13 | 1571.72 | 19 | 14.94 | 2316 | 657 | 2.27 / 207.08 | 2 | 6 |
5 | 13 | 994.00 | 19 | 15.02 | 1600 | 457 | 2.73 / 207.54 | 2 | 4 |
6 | 13 | 279.04 | 19 | 15.19 | 664 | 192 | 2.92 / 207.73 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.20 | 265 | 725 | 3.64 / 208.45 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 33 | 15.18 | 419 | 210 | 0.21 / 201.34 | 2 | 2 |
2 | 12 | 1250.00 | 3 | 15.30 | 2007 | 92 | 0.30 / 201.43 | 2 | 2 |
3 | 7 | 2004.20 | 32 | 14.95 | 2841 | 1359 | 1.66 / 202.79 | 2 | 5 |
4 | 13 | 1582.08 | 19 | 14.96 | 2329 | 662 | 2.32 / 203.45 | 2 | 3 |
5 | 13 | 994.88 | 19 | 15.04 | 1602 | 458 | 2.78 / 203.91 | 2 | 5 |
6 | 13 | 270.32 | 19 | 15.21 | 650 | 188 | 2.97 / 204.10 | 2 | 3 |
7 | 8 | 0.40 | 180 | 15.21 | 261 | 715 | 3.68 / 204.81 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 15.19 | 417 | 209 | 0.21 / 197.67 | 2 | 3 |
2 | 12 | 1246.36 | 3 | 15.30 | 1993 | 91 | 0.30 / 197.76 | 2 | 2 |
3 | 7 | 2005.72 | 31 | 14.95 | 2847 | 1319 | 1.62 / 199.08 | 2 | 3 |
4 | 13 | 1583.84 | 19 | 14.96 | 2339 | 665 | 2.28 / 199.74 | 2 | 5 |
5 | 13 | 1006.40 | 19 | 15.04 | 1616 | 462 | 2.75 / 200.20 | 2 | 7 |
6 | 13 | 295.44 | 19 | 15.21 | 681 | 197 | 2.94 / 200.40 | 2 | 3 |
7 | 8 | -0.20 | 180 | 15.22 | 265 | 726 | 3.67 / 201.13 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 32 | 15.20 | 417 | 203 | 0.20 / 193.92 | 2 | 2 |
2 | 12 | 1237.32 | 3 | 15.31 | 1981 | 91 | 0.29 / 194.01 | 2 | 2 |
3 | 7 | 2002.84 | 32 | 14.95 | 2839 | 1358 | 1.65 / 195.37 | 2 | 4 |
4 | 13 | 1579.12 | 19 | 14.97 | 2329 | 662 | 2.31 / 196.03 | 2 | 4 |
5 | 13 | 1000.84 | 19 | 15.03 | 1605 | 458 | 2.77 / 196.49 | 2 | 4 |
6 | 13 | 407.88 | 19 | 15.17 | 830 | 239 | 3.01 / 196.73 | 2 | 4 |
7 | 8 | 0.04 | 180 | 15.22 | 267 | 731 | 3.74 / 197.46 | 2 | 8 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 32 | 15.19 | 422 | 205 | 0.21 / 190.29 | 2 | 3 |
2 | 12 | 1245.12 | 3 | 15.31 | 2005 | 92 | 0.30 / 190.38 | 2 | 2 |
3 | 7 | 2003.80 | 31 | 14.96 | 2836 | 1315 | 1.61 / 191.69 | 2 | 4 |
4 | 13 | 1569.32 | 19 | 14.97 | 2318 | 659 | 2.27 / 192.35 | 2 | 6 |
5 | 13 | 999.20 | 19 | 15.04 | 1603 | 458 | 2.73 / 192.81 | 2 | 5 |
6 | 13 | 277.92 | 19 | 15.21 | 656 | 190 | 2.92 / 193.00 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.22 | 261 | 715 | 3.63 / 193.71 | 2 | 8 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 32 | 15.20 | 423 | 206 | 0.21 / 186.56 | 2 | 2 |
2 | 12 | 1265.36 | 3 | 15.32 | 2015 | 93 | 0.30 / 186.66 | 2 | 2 |
3 | 7 | 2004.76 | 31 | 14.97 | 2843 | 1319 | 1.62 / 187.98 | 2 | 6 |
4 | 13 | 1586.32 | 19 | 14.96 | 2336 | 664 | 2.28 / 188.64 | 2 | 6 |
5 | 13 | 1014.32 | 19 | 15.04 | 1622 | 464 | 2.75 / 189.10 | 2 | 5 |
6 | 13 | 426.64 | 19 | 15.18 | 857 | 247 | 2.99 / 189.35 | 2 | 4 |
7 | 8 | 0.12 | 180 | 15.23 | 266 | 729 | 3.72 / 190.08 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 32 | 15.19 | 423 | 206 | 0.21 / 182.85 | 2 | 2 |
2 | 12 | 1261.40 | 3 | 15.32 | 2016 | 93 | 0.30 / 182.94 | 2 | 2 |
3 | 7 | 2006.72 | 31 | 14.96 | 2851 | 1322 | 1.62 / 184.27 | 2 | 7 |
4 | 13 | 1584.56 | 19 | 14.97 | 2335 | 664 | 2.28 / 184.93 | 2 | 4 |
5 | 13 | 1001.56 | 19 | 15.05 | 1623 | 464 | 2.75 / 185.39 | 2 | 6 |
6 | 13 | 394.12 | 19 | 15.17 | 818 | 236 | 2.98 / 185.63 | 2 | 4 |
7 | 8 | 0.04 | 180 | 15.23 | 266 | 729 | 3.71 / 186.36 | 2 | 4 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 32 | 15.21 | 419 | 204 | 0.20 / 179.10 | 2 | 2 |
2 | 12 | 1253.64 | 3 | 15.30 | 2002 | 92 | 0.30 / 179.19 | 2 | 2 |
3 | 7 | 2002.84 | 31 | 14.97 | 2843 | 1319 | 1.62 / 180.51 | 2 | 4 |
4 | 13 | 1574.92 | 19 | 14.97 | 2321 | 660 | 2.28 / 181.17 | 2 | 4 |
5 | 13 | 997.04 | 19 | 15.06 | 1608 | 460 | 2.74 / 181.63 | 2 | 4 |
6 | 13 | 278.08 | 19 | 15.21 | 667 | 193 | 2.93 / 181.83 | 2 | 3 |
7 | 8 | -0.04 | 180 | 15.24 | 268 | 735 | 3.66 / 182.56 | 2 | 7 |
8 | 14 | -0.04 | 20 | 15.22 | 272 | 83 | 3.75 / 182.64 | 3 | 8 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 32 | 15.21 | 426 | 207 | 0.21 / 175.35 | 2 | 2 |
2 | 12 | 1253.52 | 3 | 15.31 | 2009 | 92 | 0.30 / 175.44 | 2 | 2 |
3 | 7 | 2004.60 | 31 | 14.96 | 2840 | 1317 | 1.62 / 176.76 | 2 | 4 |
4 | 13 | 1575.24 | 19 | 14.97 | 2333 | 664 | 2.28 / 177.43 | 2 | 6 |
5 | 13 | 1002.96 | 19 | 15.06 | 1616 | 462 | 2.74 / 177.89 | 2 | 6 |
6 | 13 | 282.48 | 19 | 15.22 | 669 | 193 | 2.94 / 178.08 | 2 | 3 |
7 | 8 | 1.72 | 180 | 15.24 | 268 | 735 | 3.67 / 178.82 | 2 | 7 |
8 | 14 | 1.72 | 20 | 15.22 | 271 | 82 | 3.75 / 178.90 | 3 | 10 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 32 | 15.21 | 425 | 207 | 0.21 / 171.63 | 2 | 2 |
2 | 12 | 1246.64 | 3 | 15.32 | 2002 | 92 | 0.30 / 171.72 | 2 | 2 |
3 | 7 | 2002.44 | 32 | 14.96 | 2848 | 1363 | 1.66 / 173.08 | 2 | 3 |
4 | 13 | 1577.52 | 19 | 14.98 | 2328 | 663 | 2.32 / 173.74 | 2 | 6 |
5 | 13 | 1006.44 | 19 | 15.07 | 1614 | 462 | 2.79 / 174.21 | 2 | 6 |
6 | 13 | 281.16 | 19 | 15.22 | 671 | 194 | 2.98 / 174.40 | 2 | 3 |
7 | 8 | 0.00 | 180 | 15.25 | 271 | 744 | 3.72 / 175.14 | 2 | 6 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 32 | 15.21 | 439 | 214 | 0.21 / 167.93 | 2 | 2 |
2 | 12 | 1246.48 | 3 | 15.31 | 2004 | 92 | 0.31 / 168.03 | 2 | 2 |
3 | 7 | 2002.36 | 31 | 14.99 | 2845 | 1322 | 1.63 / 169.35 | 2 | 3 |
4 | 13 | 1581.92 | 19 | 14.98 | 2337 | 665 | 2.29 / 170.01 | 2 | 4 |
5 | 13 | 1014.52 | 19 | 15.06 | 1630 | 466 | 2.76 / 170.48 | 2 | 6 |
6 | 13 | 304.08 | 19 | 15.22 | 697 | 202 | 2.96 / 170.68 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.25 | 269 | 738 | 3.70 / 171.42 | 2 | 9 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 32 | 15.21 | 422 | 205 | 0.21 / 164.26 | 2 | 3 |
2 | 12 | 1252.68 | 3 | 15.34 | 2003 | 92 | 0.30 / 164.35 | 2 | 2 |
3 | 7 | 2004.24 | 31 | 14.98 | 2829 | 1314 | 1.61 / 165.67 | 2 | 5 |
4 | 13 | 1574.20 | 19 | 14.98 | 2325 | 662 | 2.27 / 166.33 | 2 | 4 |
5 | 13 | 993.76 | 19 | 15.07 | 1604 | 459 | 2.73 / 166.79 | 2 | 5 |
6 | 13 | 281.68 | 19 | 15.23 | 668 | 193 | 2.93 / 166.98 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.25 | 270 | 741 | 3.67 / 167.72 | 2 | 5 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 32 | 15.22 | 423 | 206 | 0.21 / 160.49 | 2 | 2 |
2 | 12 | 1250.40 | 3 | 15.33 | 1985 | 91 | 0.30 / 160.59 | 2 | 2 |
3 | 7 | 2003.88 | 31 | 14.98 | 2842 | 1320 | 1.62 / 161.90 | 2 | 3 |
4 | 13 | 1577.76 | 19 | 14.99 | 2338 | 666 | 2.28 / 162.57 | 2 | 4 |
5 | 13 | 999.72 | 19 | 15.06 | 1617 | 463 | 2.75 / 163.03 | 2 | 7 |
6 | 13 | 284.92 | 19 | 15.24 | 676 | 196 | 2.94 / 163.23 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.26 | 270 | 742 | 3.68 / 163.97 | 2 | 5 |
8 | 14 | 0.16 | 20 | 15.24 | 273 | 83 | 3.77 / 164.05 | 2 | 10 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 32 | 15.22 | 430 | 209 | 0.21 / 156.84 | 2 | 2 |
2 | 12 | 1259.44 | 3 | 15.34 | 1997 | 92 | 0.30 / 156.93 | 2 | 2 |
3 | 7 | 2004.28 | 31 | 14.97 | 2842 | 1319 | 1.62 / 158.25 | 2 | 3 |
4 | 13 | 1570.16 | 19 | 14.99 | 2320 | 661 | 2.28 / 158.91 | 2 | 4 |
5 | 13 | 997.64 | 19 | 15.09 | 1605 | 460 | 2.74 / 159.37 | 2 | 6 |
6 | 13 | 267.32 | 19 | 15.24 | 647 | 187 | 2.93 / 159.55 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.26 | 267 | 733 | 3.66 / 160.29 | 2 | 9 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 32 | 15.23 | 425 | 207 | 0.21 / 153.03 | 2 | 2 |
2 | 12 | 1246.24 | 3 | 15.32 | 1980 | 91 | 0.30 / 153.12 | 2 | 2 |
3 | 7 | 2003.52 | 32 | 14.98 | 2834 | 1359 | 1.66 / 154.48 | 2 | 4 |
4 | 13 | 1572.44 | 19 | 14.99 | 2319 | 660 | 2.32 / 155.14 | 2 | 5 |
5 | 13 | 1123.24 | 19 | 15.05 | 1760 | 503 | 2.82 / 155.64 | 2 | 6 |
6 | 13 | 241.52 | 19 | 15.25 | 610 | 177 | 3.00 / 155.82 | 2 | 3 |
7 | 8 | 0.08 | 180 | 15.26 | 265 | 728 | 3.73 / 156.54 | 2 | 8 |
8 | 14 | 0.08 | 20 | 15.25 | 268 | 82 | 3.81 / 156.63 | 3 | 9 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 32 | 15.23 | 434 | 212 | 0.21 / 149.31 | 2 | 2 |
2 | 12 | 1255.40 | 3 | 15.32 | 2016 | 93 | 0.30 / 149.40 | 2 | 2 |
3 | 7 | 2002.88 | 31 | 14.98 | 2832 | 1315 | 1.62 / 150.72 | 2 | 4 |
4 | 13 | 1572.32 | 19 | 14.98 | 2311 | 658 | 2.28 / 151.37 | 2 | 5 |
5 | 13 | 1115.80 | 19 | 15.04 | 1756 | 502 | 2.78 / 151.87 | 2 | 5 |
6 | 13 | 360.00 | 19 | 15.22 | 767 | 222 | 3.00 / 152.10 | 2 | 4 |
7 | 8 | -0.08 | 180 | 15.26 | 263 | 722 | 3.72 / 152.82 | 2 | 7 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 32 | 15.24 | 426 | 208 | 0.21 / 145.60 | 2 | 3 |
2 | 12 | 1242.16 | 3 | 15.34 | 1975 | 91 | 0.30 / 145.69 | 2 | 2 |
3 | 7 | 2002.88 | 32 | 14.99 | 2839 | 1362 | 1.66 / 147.05 | 2 | 4 |
4 | 13 | 1581.20 | 19 | 15.00 | 2331 | 664 | 2.32 / 147.72 | 2 | 6 |
5 | 13 | 1001.64 | 19 | 15.08 | 1609 | 461 | 2.79 / 148.18 | 2 | 7 |
6 | 13 | 276.32 | 19 | 15.24 | 657 | 190 | 2.98 / 148.37 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.27 | 265 | 728 | 3.70 / 149.10 | 2 | 7 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 32 | 15.24 | 424 | 207 | 0.21 / 141.84 | 2 | 2 |
2 | 12 | 1246.28 | 3 | 15.33 | 1987 | 91 | 0.30 / 141.93 | 2 | 2 |
3 | 7 | 2001.68 | 31 | 15.00 | 2836 | 1319 | 1.62 / 143.25 | 2 | 3 |
4 | 13 | 1584.36 | 19 | 15.00 | 2335 | 665 | 2.28 / 143.91 | 2 | 4 |
5 | 13 | 1007.32 | 19 | 15.09 | 1615 | 463 | 2.75 / 144.38 | 2 | 5 |
6 | 13 | 295.76 | 19 | 15.24 | 683 | 198 | 2.94 / 144.58 | 2 | 3 |
7 | 8 | 0.24 | 180 | 15.28 | 267 | 734 | 3.68 / 145.31 | 2 | 7 |
8 | 14 | 0.24 | 20 | 15.25 | 269 | 82 | 3.76 / 145.39 | 2 | 9 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 32 | 15.24 | 434 | 212 | 0.21 / 138.17 | 2 | 2 |
2 | 12 | 1252.16 | 3 | 15.34 | 2002 | 92 | 0.30 / 138.26 | 2 | 2 |
3 | 7 | 2002.36 | 31 | 14.98 | 2833 | 1316 | 1.62 / 139.57 | 2 | 6 |
4 | 13 | 1580.28 | 19 | 14.99 | 2323 | 662 | 2.28 / 140.24 | 2 | 4 |
5 | 13 | 1001.60 | 19 | 15.08 | 1612 | 462 | 2.74 / 140.70 | 2 | 5 |
6 | 13 | 284.56 | 19 | 15.25 | 669 | 194 | 2.94 / 140.89 | 2 | 3 |
7 | 8 | -0.36 | 180 | 15.28 | 269 | 740 | 3.68 / 141.63 | 2 | 9 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 32 | 15.24 | 432 | 211 | 0.21 / 134.51 | 2 | 2 |
2 | 12 | 1251.76 | 3 | 15.34 | 1994 | 92 | 0.30 / 134.60 | 2 | 2 |
3 | 7 | 2001.56 | 31 | 14.99 | 2824 | 1312 | 1.61 / 135.91 | 2 | 4 |
4 | 13 | 1567.60 | 19 | 15.00 | 2309 | 658 | 2.27 / 136.57 | 2 | 4 |
5 | 13 | 988.72 | 19 | 15.09 | 1592 | 456 | 2.73 / 137.03 | 2 | 4 |
6 | 13 | 273.12 | 19 | 15.24 | 651 | 189 | 2.92 / 137.22 | 2 | 4 |
7 | 8 | 0.00 | 180 | 15.27 | 269 | 739 | 3.66 / 137.96 | 2 | 11 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 32 | 15.23 | 429 | 209 | 0.21 / 130.84 | 2 | 2 |
2 | 12 | 1244.76 | 3 | 15.35 | 1981 | 91 | 0.30 / 130.93 | 2 | 2 |
3 | 7 | 2002.28 | 31 | 14.99 | 2836 | 1318 | 1.62 / 132.25 | 2 | 4 |
4 | 13 | 1577.64 | 19 | 14.99 | 2330 | 664 | 2.28 / 132.91 | 2 | 5 |
5 | 13 | 997.08 | 19 | 15.09 | 1601 | 459 | 2.74 / 133.37 | 2 | 6 |
6 | 13 | 275.72 | 19 | 15.25 | 660 | 191 | 2.93 / 133.56 | 2 | 4 |
7 | 8 | 0.04 | 180 | 15.28 | 267 | 734 | 3.67 / 134.30 | 2 | 6 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 32 | 15.25 | 429 | 209 | 0.21 / 127.08 | 2 | 2 |
2 | 12 | 1265.56 | 3 | 15.32 | 2011 | 92 | 0.30 / 127.18 | 2 | 2 |
3 | 7 | 2002.32 | 31 | 15.00 | 2841 | 1321 | 1.62 / 128.50 | 2 | 4 |
4 | 13 | 1466.16 | 19 | 15.03 | 2192 | 626 | 2.25 / 129.12 | 2 | 6 |
5 | 13 | 1041.96 | 19 | 15.09 | 1663 | 477 | 2.73 / 129.60 | 2 | 6 |
6 | 13 | 307.44 | 19 | 15.25 | 701 | 203 | 2.93 / 129.80 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.28 | 271 | 745 | 3.67 / 130.55 | 2 | 5 |
8 | 14 | 0.20 | 20 | 15.27 | 275 | 84 | 3.76 / 130.63 | 2 | 4 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 32 | 15.26 | 431 | 210 | 0.21 / 123.32 | 2 | 2 |
2 | 12 | 1251.04 | 3 | 15.35 | 1987 | 92 | 0.30 / 123.41 | 2 | 2 |
3 | 7 | 2003.76 | 31 | 14.99 | 2836 | 1318 | 1.62 / 124.73 | 2 | 5 |
4 | 13 | 1576.84 | 19 | 15.02 | 2329 | 665 | 2.28 / 125.40 | 2 | 6 |
5 | 13 | 1001.72 | 19 | 15.10 | 1618 | 464 | 2.75 / 125.86 | 2 | 6 |
6 | 13 | 280.84 | 19 | 15.26 | 664 | 193 | 2.94 / 126.05 | 2 | 3 |
7 | 8 | 0.20 | 180 | 15.28 | 269 | 740 | 3.68 / 126.79 | 2 | 4 |
8 | 14 | 0.20 | 20 | 15.26 | 266 | 81 | 3.76 / 126.87 | 2 | 3 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 32 | 15.25 | 435 | 212 | 0.21 / 119.59 | 2 | 3 |
2 | 12 | 1251.48 | 3 | 15.35 | 2001 | 92 | 0.30 / 119.68 | 2 | 2 |
3 | 7 | 2004.16 | 32 | 15.01 | 2836 | 1362 | 1.67 / 121.04 | 2 | 6 |
4 | 13 | 1582.72 | 19 | 15.02 | 2334 | 666 | 2.33 / 121.71 | 2 | 6 |
5 | 13 | 1003.28 | 19 | 15.11 | 1617 | 464 | 2.80 / 122.17 | 2 | 7 |
6 | 13 | 278.40 | 19 | 15.26 | 668 | 194 | 2.99 / 122.37 | 2 | 4 |
7 | 8 | -0.08 | 180 | 15.29 | 270 | 743 | 3.73 / 123.11 | 2 | 3 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 32 | 15.26 | 437 | 213 | 0.21 / 115.91 | 2 | 2 |
2 | 12 | 1257.88 | 3 | 15.35 | 2029 | 93 | 0.31 / 116.00 | 2 | 2 |
3 | 7 | 2001.68 | 31 | 15.00 | 2838 | 1320 | 1.63 / 117.32 | 2 | 7 |
4 | 13 | 1572.48 | 19 | 15.02 | 2326 | 664 | 2.29 / 117.98 | 2 | 5 |
5 | 13 | 993.60 | 19 | 15.11 | 1608 | 462 | 2.75 / 118.45 | 2 | 6 |
6 | 13 | 268.20 | 19 | 15.27 | 650 | 189 | 2.94 / 118.63 | 2 | 3 |
7 | 8 | -0.04 | 180 | 15.29 | 270 | 743 | 3.68 / 119.38 | 2 | 8 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 32 | 15.26 | 428 | 209 | 0.21 / 112.21 | 2 | 3 |
2 | 12 | 1266.60 | 3 | 15.35 | 2025 | 93 | 0.30 / 112.30 | 2 | 2 |
3 | 7 | 2002.84 | 31 | 15.01 | 2834 | 1319 | 1.62 / 113.62 | 2 | 4 |
4 | 13 | 1578.28 | 19 | 15.02 | 2326 | 664 | 2.28 / 114.28 | 2 | 4 |
5 | 13 | 1006.60 | 19 | 15.11 | 1619 | 465 | 2.75 / 114.75 | 2 | 5 |
6 | 13 | 299.40 | 19 | 15.26 | 699 | 203 | 2.95 / 114.95 | 2 | 3 |
7 | 8 | 0.40 | 180 | 15.29 | 271 | 746 | 3.70 / 115.69 | 2 | 8 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 32 | 15.25 | 420 | 205 | 0.20 / 108.53 | 2 | 2 |
2 | 12 | 1256.32 | 3 | 15.37 | 2001 | 92 | 0.30 / 108.62 | 2 | 2 |
3 | 7 | 2002.96 | 31 | 15.02 | 2841 | 1323 | 1.62 / 109.95 | 2 | 4 |
4 | 13 | 1578.16 | 19 | 15.02 | 2338 | 667 | 2.29 / 110.61 | 2 | 5 |
5 | 13 | 992.96 | 19 | 15.12 | 1603 | 461 | 2.75 / 111.07 | 2 | 6 |
6 | 13 | 271.08 | 19 | 15.28 | 653 | 190 | 2.94 / 111.26 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.30 | 266 | 733 | 3.67 / 112.00 | 2 | 10 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 32 | 15.25 | 432 | 211 | 0.21 / 104.79 | 2 | 2 |
2 | 12 | 1247.32 | 3 | 15.35 | 2001 | 92 | 0.30 / 104.88 | 2 | 2 |
3 | 7 | 2004.20 | 31 | 15.00 | 2837 | 1319 | 1.62 / 106.20 | 2 | 5 |
4 | 13 | 1576.96 | 19 | 15.03 | 2327 | 665 | 2.29 / 106.87 | 2 | 3 |
5 | 13 | 998.56 | 19 | 15.11 | 1609 | 462 | 2.75 / 107.33 | 2 | 5 |
6 | 13 | 277.00 | 19 | 15.27 | 663 | 192 | 2.94 / 107.52 | 2 | 3 |
7 | 8 | 0.04 | 180 | 15.29 | 263 | 724 | 3.66 / 108.24 | 2 | 7 |
8 | 14 | 0.04 | 20 | 15.27 | 267 | 82 | 3.75 / 108.33 | 3 | 10 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 32 | 15.26 | 438 | 214 | 0.21 / 100.98 | 2 | 2 |
2 | 12 | 1254.80 | 3 | 15.36 | 2004 | 92 | 0.31 / 101.07 | 2 | 2 |
3 | 7 | 2003.04 | 31 | 15.01 | 2835 | 1319 | 1.63 / 102.39 | 2 | 4 |
4 | 13 | 1577.40 | 19 | 15.02 | 2330 | 665 | 2.29 / 103.05 | 2 | 7 |
5 | 13 | 1004.12 | 19 | 15.11 | 1614 | 463 | 2.75 / 103.52 | 2 | 8 |
6 | 13 | 404.20 | 19 | 15.24 | 829 | 240 | 2.99 / 103.76 | 2 | 4 |
7 | 8 | 0.04 | 180 | 15.29 | 269 | 740 | 3.73 / 104.50 | 2 | 9 |
8 | 14 | 0.04 | 20 | 15.28 | 270 | 83 | 3.82 / 104.58 | 3 | 7 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 32 | 15.26 | 423 | 207 | 0.21 / 97.24 | 2 | 2 |
2 | 12 | 1247.48 | 3 | 15.36 | 1989 | 92 | 0.30 / 97.34 | 2 | 2 |
3 | 7 | 2002.12 | 31 | 15.02 | 2843 | 1324 | 1.62 / 98.66 | 2 | 3 |
4 | 13 | 1579.08 | 19 | 15.04 | 2334 | 667 | 2.29 / 99.33 | 2 | 4 |
5 | 13 | 1003.68 | 19 | 15.11 | 1609 | 462 | 2.75 / 99.79 | 2 | 7 |
6 | 13 | 409.24 | 19 | 15.24 | 830 | 240 | 2.99 / 100.03 | 2 | 4 |
7 | 8 | 0.24 | 180 | 15.30 | 267 | 735 | 3.73 / 100.76 | 2 | 9 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 32 | 15.26 | 433 | 211 | 0.21 / 93.58 | 2 | 2 |
2 | 12 | 1269.64 | 3 | 15.34 | 2030 | 93 | 0.30 / 93.68 | 2 | 2 |
3 | 7 | 2001.76 | 31 | 15.01 | 2841 | 1322 | 1.63 / 95.00 | 2 | 6 |
4 | 13 | 1572.96 | 19 | 15.04 | 2321 | 663 | 2.29 / 95.66 | 2 | 6 |
5 | 13 | 989.32 | 19 | 15.13 | 1597 | 459 | 2.75 / 96.12 | 2 | 8 |
6 | 13 | 260.64 | 19 | 15.29 | 639 | 186 | 2.93 / 96.31 | 2 | 3 |
7 | 8 | -0.12 | 180 | 15.30 | 265 | 730 | 3.66 / 97.04 | 2 | 8 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 32 | 15.26 | 418 | 204 | 0.20 / 89.92 | 2 | 2 |
2 | 12 | 1246.28 | 3 | 15.37 | 1992 | 92 | 0.30 / 90.01 | 2 | 2 |
3 | 7 | 2003.40 | 31 | 15.02 | 2837 | 1321 | 1.62 / 91.33 | 2 | 3 |
4 | 13 | 1572.08 | 19 | 15.04 | 2324 | 664 | 2.28 / 92.00 | 2 | 4 |
5 | 13 | 992.00 | 19 | 15.13 | 1594 | 458 | 2.74 / 92.45 | 2 | 7 |
6 | 13 | 259.20 | 19 | 15.29 | 639 | 186 | 2.92 / 92.64 | 2 | 3 |
7 | 8 | 0.00 | 180 | 15.31 | 266 | 733 | 3.66 / 93.37 | 2 | 8 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 32 | 15.28 | 423 | 207 | 0.21 / 86.25 | 2 | 2 |
2 | 12 | 1269.72 | 3 | 15.37 | 2030 | 94 | 0.30 / 86.35 | 2 | 2 |
3 | 7 | 2001.44 | 31 | 15.03 | 2830 | 1319 | 1.62 / 87.67 | 2 | 4 |
4 | 13 | 1574.44 | 19 | 15.05 | 2333 | 667 | 2.29 / 88.33 | 2 | 7 |
5 | 13 | 993.64 | 19 | 15.13 | 1599 | 460 | 2.75 / 88.79 | 2 | 5 |
6 | 13 | 266.84 | 19 | 15.28 | 651 | 189 | 2.93 / 88.98 | 2 | 4 |
7 | 8 | 0.28 | 180 | 15.31 | 266 | 733 | 3.67 / 89.71 | 2 | 6 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 32 | 15.27 | 425 | 208 | 0.21 / 82.59 | 2 | 2 |
2 | 12 | 1248.96 | 3 | 15.37 | 2004 | 92 | 0.30 / 82.69 | 2 | 2 |
3 | 7 | 2005.80 | 31 | 15.03 | 2843 | 1325 | 1.62 / 84.01 | 2 | 5 |
4 | 13 | 1577.84 | 19 | 15.04 | 2334 | 667 | 2.29 / 84.68 | 2 | 6 |
5 | 13 | 990.96 | 19 | 15.14 | 1592 | 458 | 2.75 / 85.14 | 2 | 8 |
6 | 13 | 257.12 | 19 | 15.30 | 633 | 184 | 2.93 / 85.32 | 2 | 3 |
7 | 8 | 0.16 | 180 | 15.31 | 264 | 728 | 3.66 / 86.05 | 2 | 6 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 32 | 15.27 | 422 | 206 | 0.21 / 78.94 | 2 | 2 |
2 | 12 | 1250.00 | 3 | 15.38 | 1993 | 92 | 0.30 / 79.03 | 2 | 2 |
3 | 7 | 2001.24 | 31 | 15.03 | 2836 | 1321 | 1.62 / 80.36 | 2 | 3 |
4 | 13 | 1568.32 | 18 | 15.06 | 2323 | 630 | 2.25 / 80.99 | 2 | 4 |
5 | 13 | 995.40 | 18 | 15.16 | 1604 | 438 | 2.69 / 81.42 | 2 | 5 |
6 | 13 | 411.72 | 18 | 15.27 | 842 | 231 | 2.92 / 81.66 | 2 | 4 |
7 | 8 | 0.00 | 180 | 15.31 | 265 | 730 | 3.65 / 82.39 | 2 | 5 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 32 | 15.28 | 420 | 205 | 0.21 / 75.11 | 2 | 3 |
2 | 12 | 1252.84 | 3 | 15.39 | 2014 | 93 | 0.30 / 75.20 | 2 | 2 |
3 | 7 | 2001.20 | 31 | 15.04 | 2826 | 1318 | 1.62 / 76.52 | 2 | 3 |
4 | 13 | 1578.72 | 18 | 15.06 | 2331 | 632 | 2.25 / 77.15 | 2 | 8 |
5 | 13 | 1016.32 | 18 | 15.14 | 1630 | 444 | 2.69 / 77.60 | 2 | 4 |
6 | 13 | 437.04 | 18 | 15.27 | 872 | 240 | 2.93 / 77.84 | 2 | 5 |
7 | 13 | 21.40 | 18 | 15.36 | 309 | 85 | 3.02 / 77.92 | 2 | 3 |
8 | 8 | 0.28 | 180 | 15.31 | 266 | 733 | 3.75 / 78.66 | 2 | 8 |
9 | 14 | 0.28 | 20 | 15.30 | 266 | 81 | 3.83 / 78.74 | 3 | 8 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 32 | 15.29 | 427 | 209 | 0.21 / 71.46 | 2 | 3 |
2 | 12 | 1248.28 | 3 | 15.38 | 1984 | 92 | 0.30 / 71.55 | 2 | 3 |
3 | 7 | 2003.16 | 31 | 15.03 | 2832 | 1320 | 1.62 / 72.87 | 2 | 7 |
4 | 13 | 1580.76 | 18 | 15.07 | 2340 | 635 | 2.25 / 73.50 | 2 | 7 |
5 | 13 | 1004.68 | 18 | 15.15 | 1611 | 439 | 2.69 / 73.94 | 2 | 5 |
6 | 13 | 417.88 | 18 | 15.27 | 846 | 233 | 2.93 / 74.17 | 2 | 5 |
7 | 8 | 0.12 | 180 | 15.32 | 265 | 731 | 3.66 / 74.91 | 2 | 7 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 32 | 15.28 | 417 | 204 | 0.20 / 67.83 | 2 | 2 |
2 | 12 | 1261.96 | 3 | 15.39 | 2004 | 93 | 0.30 / 67.92 | 2 | 3 |
3 | 7 | 2001.92 | 31 | 15.05 | 2839 | 1325 | 1.62 / 69.25 | 2 | 4 |
4 | 13 | 1578.36 | 18 | 15.08 | 2327 | 632 | 2.25 / 69.88 | 2 | 7 |
5 | 13 | 1017.56 | 18 | 15.15 | 1625 | 443 | 2.70 / 70.32 | 2 | 4 |
6 | 13 | 447.52 | 18 | 15.27 | 881 | 242 | 2.94 / 70.56 | 2 | 5 |
7 | 8 | 0.04 | 170 | 15.33 | 263 | 685 | 3.62 / 71.25 | 2 | 6 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 32 | 15.29 | 409 | 200 | 0.20 / 64.25 | 2 | 2 |
2 | 12 | 1247.52 | 2 | 15.40 | 2009 | 62 | 0.26 / 64.31 | 2 | 2 |
3 | 7 | 2005.92 | 33 | 15.03 | 2838 | 1408 | 1.67 / 65.72 | 2 | 6 |
4 | 13 | 1443.64 | 18 | 15.10 | 2169 | 590 | 2.26 / 66.31 | 2 | 7 |
5 | 13 | 1018.96 | 18 | 15.15 | 1640 | 447 | 2.71 / 66.75 | 2 | 6 |
6 | 13 | 291.28 | 18 | 15.30 | 678 | 187 | 2.89 / 66.94 | 2 | 3 |
7 | 8 | 0.12 | 170 | 15.33 | 263 | 685 | 3.58 / 67.62 | 2 | 5 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 32 | 15.30 | 427 | 209 | 0.21 / 60.50 | 2 | 2 |
2 | 12 | 1256.04 | 2 | 15.42 | 2011 | 62 | 0.27 / 60.57 | 2 | 2 |
3 | 7 | 2004.32 | 34 | 15.03 | 2838 | 1450 | 1.72 / 62.02 | 2 | 5 |
4 | 13 | 1450.36 | 18 | 15.11 | 2182 | 593 | 2.31 / 62.61 | 2 | 4 |
5 | 13 | 1020.16 | 18 | 15.15 | 1637 | 446 | 2.76 / 63.06 | 2 | 6 |
6 | 13 | 283.80 | 18 | 15.31 | 674 | 186 | 2.95 / 63.24 | 2 | 3 |
7 | 8 | 0.12 | 170 | 15.33 | 262 | 683 | 3.63 / 63.93 | 2 | 12 |
8 | 14 | 0.12 | 30 | 15.31 | 263 | 121 | 3.75 / 64.05 | 3 | 8 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 32 | 15.30 | 423 | 207 | 0.21 / 56.84 | 2 | 2 |
2 | 12 | 1271.04 | 2 | 15.41 | 2036 | 63 | 0.27 / 56.90 | 2 | 2 |
3 | 7 | 2007.12 | 33 | 15.04 | 2837 | 1408 | 1.68 / 58.31 | 2 | 5 |
4 | 13 | 1568.28 | 18 | 15.08 | 2319 | 629 | 2.31 / 58.94 | 2 | 4 |
5 | 13 | 997.04 | 18 | 15.16 | 1611 | 440 | 2.75 / 59.38 | 2 | 6 |
6 | 13 | 403.84 | 18 | 15.29 | 829 | 228 | 2.98 / 59.61 | 2 | 4 |
7 | 8 | -0.08 | 170 | 15.34 | 263 | 686 | 3.66 / 60.30 | 2 | 4 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 32 | 15.30 | 431 | 211 | 0.21 / 53.18 | 2 | 3 |
2 | 12 | 1279.92 | 2 | 15.39 | 2040 | 63 | 0.27 / 53.24 | 2 | 3 |
3 | 7 | 2002.40 | 33 | 15.04 | 2824 | 1402 | 1.68 / 54.64 | 2 | 4 |
4 | 13 | 1571.40 | 18 | 15.09 | 2326 | 632 | 2.31 / 55.28 | 2 | 7 |
5 | 13 | 994.72 | 18 | 15.17 | 1606 | 439 | 2.75 / 55.72 | 2 | 6 |
6 | 13 | 406.24 | 18 | 15.28 | 831 | 229 | 2.97 / 55.94 | 2 | 6 |
7 | 8 | 0.16 | 170 | 15.33 | 265 | 691 | 3.66 / 56.63 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 32 | 15.30 | 425 | 208 | 0.21 / 49.50 | 2 | 2 |
2 | 12 | 1290.52 | 2 | 15.41 | 2046 | 63 | 0.27 / 49.56 | 2 | 2 |
3 | 7 | 2005.16 | 33 | 15.05 | 2841 | 1411 | 1.68 / 50.97 | 2 | 6 |
4 | 13 | 1565.52 | 18 | 15.10 | 2319 | 630 | 2.31 / 51.61 | 2 | 7 |
5 | 13 | 992.08 | 18 | 15.17 | 1604 | 438 | 2.75 / 52.04 | 2 | 5 |
6 | 13 | 403.92 | 18 | 15.29 | 826 | 227 | 2.98 / 52.27 | 2 | 3 |
7 | 8 | 0.12 | 170 | 15.34 | 268 | 699 | 3.68 / 52.97 | 2 | 6 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 32 | 15.31 | 425 | 208 | 0.21 / 45.70 | 2 | 2 |
2 | 7 | 2004.20 | 31 | 15.07 | 2835 | 1324 | 1.53 / 47.02 | 2 | 5 |
3 | 13 | 1593.80 | 18 | 15.09 | 2353 | 639 | 2.17 / 47.66 | 2 | 5 |
4 | 13 | 1155.40 | 18 | 15.15 | 1807 | 493 | 2.66 / 48.15 | 2 | 4 |
5 | 13 | 436.36 | 18 | 15.29 | 874 | 241 | 2.91 / 48.39 | 2 | 5 |
6 | 13 | 25.16 | 18 | 15.38 | 313 | 87 | 2.99 / 48.48 | 2 | 3 |
7 | 8 | 0.00 | 170 | 15.34 | 265 | 691 | 3.68 / 49.17 | 2 | 6 |
8 | 14 | 0.00 | 30 | 15.33 | 265 | 122 | 3.80 / 49.29 | 3 | 12 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 32 | 15.31 | 432 | 212 | 0.21 / 42.12 | 2 | 2 |
2 | 7 | 2006.52 | 31 | 15.07 | 2844 | 1329 | 1.54 / 43.45 | 2 | 4 |
3 | 13 | 1606.12 | 18 | 15.09 | 2365 | 642 | 2.18 / 44.09 | 2 | 5 |
4 | 13 | 1051.88 | 18 | 15.16 | 1673 | 457 | 2.64 / 44.55 | 2 | 4 |
5 | 13 | 473.72 | 18 | 15.27 | 919 | 253 | 2.89 / 44.80 | 2 | 5 |
6 | 8 | 0.16 | 170 | 15.35 | 263 | 686 | 3.58 / 45.49 | 2 | 5 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 32 | 15.32 | 427 | 209 | 0.21 / 38.52 | 2 | 3 |
2 | 7 | 2007.36 | 31 | 15.07 | 2844 | 1329 | 1.54 / 39.85 | 2 | 4 |
3 | 13 | 1606.88 | 18 | 15.10 | 2364 | 643 | 2.18 / 40.49 | 2 | 5 |
4 | 13 | 1056.72 | 18 | 15.17 | 1685 | 460 | 2.64 / 40.95 | 2 | 4 |
5 | 13 | 489.88 | 18 | 15.27 | 942 | 259 | 2.90 / 41.21 | 2 | 4 |
6 | 8 | 0.24 | 170 | 15.35 | 267 | 697 | 3.60 / 41.91 | 2 | 6 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 31 | 15.32 | 427 | 203 | 0.20 / 34.90 | 2 | 3 |
2 | 7 | 2007.84 | 31 | 15.08 | 2842 | 1329 | 1.53 / 36.23 | 2 | 4 |
3 | 13 | 1612.84 | 18 | 15.10 | 2383 | 648 | 2.18 / 36.87 | 2 | 4 |
4 | 13 | 1177.32 | 18 | 15.14 | 1840 | 501 | 2.68 / 37.37 | 2 | 6 |
5 | 13 | 452.72 | 18 | 15.28 | 892 | 245 | 2.93 / 37.62 | 2 | 5 |
6 | 8 | 0.16 | 170 | 15.35 | 266 | 694 | 3.62 / 38.31 | 2 | 7 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 31 | 15.31 | 424 | 201 | 0.20 / 31.04 | 2 | 2 |
2 | 7 | 2004.12 | 31 | 15.08 | 2838 | 1327 | 1.53 / 32.37 | 2 | 3 |
3 | 13 | 1591.84 | 18 | 15.11 | 2352 | 640 | 2.17 / 33.01 | 2 | 5 |
4 | 13 | 1152.24 | 18 | 15.15 | 1810 | 494 | 2.66 / 33.50 | 2 | 9 |
5 | 13 | 553.36 | 18 | 15.27 | 1027 | 282 | 2.94 / 33.79 | 2 | 7 |
6 | 13 | 26.20 | 18 | 15.38 | 318 | 88 | 3.03 / 33.87 | 2 | 3 |
7 | 8 | -0.20 | 170 | 15.35 | 267 | 697 | 3.73 / 34.57 | 2 | 6 |
8 | 14 | -0.20 | 30 | 15.33 | 268 | 123 | 3.85 / 34.69 | 2 | 10 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 31 | 15.33 | 426 | 202 | 0.20 / 27.48 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 15.08 | 2831 | 1323 | 1.53 / 28.80 | 2 | 3 |
3 | 13 | 1593.88 | 18 | 15.11 | 2347 | 638 | 2.16 / 29.44 | 2 | 8 |
4 | 13 | 1042.00 | 18 | 15.17 | 1668 | 455 | 2.62 / 29.90 | 2 | 8 |
5 | 13 | 469.80 | 18 | 15.28 | 918 | 252 | 2.87 / 30.15 | 2 | 4 |
6 | 8 | 0.16 | 170 | 15.36 | 266 | 695 | 3.57 / 30.84 | 2 | 5 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 31 | 15.32 | 423 | 201 | 0.20 / 23.80 | 2 | 2 |
2 | 3 | 1017.08 | 1 | 15.40 | 1679 | 26 | 0.23 / 23.83 | 2 | 3 |
3 | 7 | 2005.40 | 31 | 15.11 | 2828 | 1325 | 1.55 / 25.16 | 2 | 3 |
4 | 13 | 1604.68 | 18 | 15.12 | 2352 | 640 | 2.19 / 25.80 | 2 | 6 |
5 | 13 | 1177.64 | 18 | 15.16 | 1830 | 499 | 2.69 / 26.29 | 2 | 6 |
6 | 13 | 587.24 | 18 | 15.27 | 1068 | 294 | 2.98 / 26.59 | 2 | 7 |
7 | 8 | 0.12 | 170 | 15.37 | 263 | 687 | 3.67 / 27.28 | 2 | 4 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 15.33 | 427 | 190 | 0.19 / 19.53 | 2 | 2 |
2 | 10 | 1011.00 | 2 | 15.30 | 1657 | 51 | 0.24 / 19.59 | 2 | 3 |
3 | 7 | 2003.76 | 75 | 14.93 | 2805 | 3141 | 3.38 / 22.73 | 2 | 3 |
4 | 13 | 372.56 | 18 | 15.31 | 783 | 216 | 3.60 / 22.94 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.37 | 261 | 662 | 4.26 / 23.60 | 2 | 5 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 26 | 15.32 | 424 | 169 | 0.17 / 15.22 | 2 | 2 |
2 | 10 | 1025.72 | 3 | 15.28 | 1683 | 77 | 0.25 / 15.29 | 2 | 2 |
3 | 3 | 1054.00 | 2 | 15.33 | 1743 | 53 | 0.30 / 15.35 | 2 | 3 |
4 | 7 | 2003.96 | 74 | 14.93 | 2812 | 3107 | 3.41 / 18.45 | 2 | 3 |
5 | 13 | 388.68 | 18 | 15.32 | 810 | 223 | 3.63 / 18.68 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.36 | 264 | 669 | 4.30 / 19.34 | 2 | 4 |
Average= | 3.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 30 | 15.32 | 434 | 199 | 0.20 / 11.48 | 2 | 2 |
2 | 7 | 1513.68 | 74 | 15.08 | 2209 | 2465 | 2.66 / 13.95 | 2 | 3 |
3 | 13 | 147.28 | 18 | 15.36 | 479 | 132 | 2.80 / 14.08 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.36 | 262 | 664 | 3.46 / 14.75 | 2 | 9 |
5 | 14 | 0.08 | 75 | 15.33 | 261 | 300 | 3.76 / 15.05 | 2 | 8 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 29 | 15.30 | 426 | 189 | 0.19 / 7.97 | 2 | 2 |
2 | 3 | 1019.00 | 1 | 15.38 | 1693 | 26 | 0.22 / 8.00 | 2 | 3 |
3 | 7 | 1519.52 | 74 | 15.06 | 2215 | 2468 | 2.68 / 10.47 | 2 | 3 |
4 | 13 | 189.04 | 18 | 15.35 | 540 | 149 | 2.83 / 10.62 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.36 | 263 | 667 | 3.50 / 11.29 | 2 | 6 |
Average= | 2.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 28 | 15.27 | 427 | 183 | 0.18 / 4.44 | 2 | 2 |
2 | 10 | 1009.36 | 2 | 15.23 | 1646 | 50 | 0.23 / 4.49 | 2 | 3 |
3 | 7 | 1514.44 | 75 | 15.03 | 2213 | 2495 | 2.73 / 6.98 | 2 | 3 |
4 | 13 | 127.80 | 18 | 15.34 | 463 | 128 | 2.86 / 7.11 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.33 | 267 | 675 | 3.53 / 7.79 | 2 | 5 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 24 | 15.49 | 426 | 158 | 0.16 / 1.67 | 2 | 2 |
2 | 10 | 1043.92 | 3 | 15.32 | 1690 | 78 | 0.24 / 1.75 | 2 | 2 |
3 | 3 | 1080.04 | 2 | 15.31 | 1767 | 54 | 0.29 / 1.81 | 2 | 3 |
4 | 7 | 1008.36 | 74 | 15.16 | 1581 | 1774 | 2.06 / 3.58 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.33 | 267 | 675 | 2.74 / 4.26 | 2 | 11 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 52.52 | 24 | 15.63 | 357 | 134 | 0.13 / 0.13 | 2 | 2 |
2 | 7 | 66.72 | 74 | 15.58 | 367 | 423 | 0.56 / 0.56 | 2 | 3 |
3 | 8 | 0.12 | 240 | 15.55 | 257 | 959 | 1.52 / 1.52 | 2 | 13 |
Average= | 1.52 (KJ/cycle) |