Cycle 159 GMT 12/12/2024 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 33 14.98 467 231 0.23 / 598.43 2 2
2 12 1300.08 2 15.23 2091 64 0.29 / 598.49 2 2
3 7 2005.08 31 14.91 2912 1346 1.64 / 599.83 2 3
4 13 1590.76 19 14.89 2391 676 2.32 / 600.51 2 6
5 13 1019.44 19 14.91 1656 469 2.79 / 600.98 2 4
6 13 299.36 19 15.01 707 202 2.99 / 601.18 2 3
7 8 0.20 175 15.04 287 755 3.74 / 601.94 2 3
Average= 3.76
(KJ/cycle)

Cycle 158 GMT 2/12/2024 15:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 32 15.00 460 221 0.22 / 594.52 2 2
2 3 1027.28 1 15.10 1733 26 0.25 / 594.55 2 2
3 12 1315.56 2 15.21 2133 65 0.31 / 594.61 2 2
4 7 2005.36 31 14.89 2896 1337 1.65 / 595.95 2 3
5 13 1585.72 19 14.88 2388 675 2.32 / 596.63 2 5
6 13 1011.44 19 14.92 1644 466 2.79 / 597.09 2 3
7 13 405.00 19 15.00 831 237 3.03 / 597.33 2 3
8 8 0.04 175 15.04 295 776 3.80 / 598.10 2 4
9 14 0.04 20 15.02 298 90 3.89 / 598.19 2 5
Average= 3.76
(KJ/cycle)

Cycle 157 GMT 22/11/2024 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 15.01 464 223 0.22 / 590.80 2 2
2 12 1335.76 2 15.22 2140 65 0.29 / 590.87 2 2
3 7 2010.68 31 14.91 2925 1352 1.64 / 592.22 2 2
4 13 1592.84 19 14.89 2402 680 2.32 / 592.90 2 4
5 13 1013.28 19 14.93 1645 467 2.79 / 593.37 2 5
6 13 293.56 19 15.04 680 194 2.98 / 593.56 2 3
7 8 0.00 175 15.06 281 741 3.72 / 594.30 2 4
Average= 3.76
(KJ/cycle)

Cycle 156 GMT 13/11/2024 0:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 33 14.98 482 238 0.24 / 586.96 2 2
2 12 1274.96 2 15.23 2069 63 0.30 / 587.02 2 2
3 7 2007.84 31 14.91 2929 1354 1.66 / 588.37 2 2
4 13 1581.08 19 14.89 2388 676 2.33 / 589.05 2 3
5 13 1002.56 19 14.93 1637 464 2.80 / 589.51 2 3
6 13 301.96 19 15.04 697 199 2.99 / 589.71 2 3
7 8 0.16 175 15.06 296 780 3.77 / 590.49 2 3
8 14 0.16 20 15.04 298 90 3.86 / 590.58 2 3
Average= 3.76
(KJ/cycle)

Cycle 155 GMT 3/11/2024 5:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 14.99 452 224 0.22 / 583.21 2 2
2 12 1142.84 2 15.25 1883 57 0.28 / 583.27 2 2
3 7 2002.96 31 14.89 2897 1337 1.62 / 584.61 2 2
4 13 1581.28 19 14.87 2384 674 2.29 / 585.28 2 5
5 13 998.48 19 14.90 1631 462 2.75 / 585.74 2 3
6 13 278.04 19 15.01 678 193 2.95 / 585.94 2 3
7 8 0.04 175 15.03 296 779 3.73 / 586.72 2 3
Average= 3.76
(KJ/cycle)

Cycle 154 GMT 24/10/2024 9:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 33 14.98 476 235 0.24 / 579.36 2 2
2 12 1312.20 2 15.21 2120 64 0.30 / 579.43 2 2
3 7 2003.88 31 14.89 2904 1340 1.64 / 580.77 2 2
4 13 1590.24 19 14.88 2391 676 2.32 / 581.44 2 5
5 13 1016.48 19 14.92 1648 467 2.78 / 581.91 2 3
6 13 421.24 19 14.99 857 244 3.03 / 582.16 2 3
7 8 0.16 175 15.04 284 747 3.77 / 582.90 2 3
8 14 0.16 20 15.02 292 88 3.86 / 582.99 2 3
Average= 3.76
(KJ/cycle)

Cycle 153 GMT 14/10/2024 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 33 14.98 478 236 0.24 / 575.59 2 2
2 12 1317.56 2 15.23 2118 65 0.30 / 575.65 2 2
3 7 2006.36 31 14.90 2921 1349 1.65 / 577.00 2 2
4 13 1589.32 19 14.89 2391 676 2.33 / 577.68 2 2
5 13 1015.36 19 14.92 1648 467 2.79 / 578.14 2 4
6 13 296.08 19 15.02 681 194 2.99 / 578.34 2 3
7 8 0.20 175 15.04 300 790 3.78 / 579.13 2 3
Average= 3.76
(KJ/cycle)

Cycle 152 GMT 4/10/2024 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 33 14.98 476 235 0.24 / 571.72 2 2
2 12 1153.24 2 15.26 1880 57 0.29 / 571.78 2 2
3 7 2005.96 32 14.90 2906 1386 1.68 / 573.16 2 2
4 13 1587.60 19 14.88 2392 676 2.35 / 573.84 2 3
5 13 1014.60 19 14.92 1650 468 2.82 / 574.31 2 4
6 13 290.28 19 15.03 670 191 3.01 / 574.50 2 3
7 8 -0.36 175 15.04 290 763 3.78 / 575.26 2 5
8 14 -0.36 20 15.02 301 90 3.87 / 575.35 2 3
Average= 3.76
(KJ/cycle)

Cycle 151 GMT 25/ 9/2024 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 33 14.96 474 234 0.23 / 567.92 2 2
2 12 1305.28 2 15.22 2096 64 0.30 / 567.99 2 2
3 7 2003.04 32 14.90 2897 1381 1.68 / 569.37 2 3
4 13 1581.72 19 14.89 2376 672 2.35 / 570.04 2 2
5 13 1013.40 19 14.92 1644 466 2.82 / 570.51 2 4
6 13 295.48 19 15.01 682 194 3.01 / 570.70 2 3
7 8 -0.08 175 15.02 298 783 3.80 / 571.48 2 3
Average= 3.76
(KJ/cycle)

Cycle 150 GMT 15/ 9/2024 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 33 14.99 464 230 0.23 / 563.26 2 2
2 12 1305.20 2 15.24 2101 64 0.29 / 563.33 2 2
3 7 2003.36 31 14.90 2905 1342 1.64 / 564.67 2 3
4 13 1579.92 19 14.88 2378 672 2.31 / 565.34 2 4
5 13 1109.56 19 14.89 1758 497 2.81 / 565.84 2 4
6 13 1093.24 19 14.85 1744 492 3.30 / 566.33 2 4
7 13 1033.20 19 14.80 1662 467 3.76 / 566.80 2 3
8 8 0.52 175 15.00 304 798 4.56 / 567.60 2 4
9 14 0.52 20 14.98 303 91 4.65 / 567.69 2 3
Average= 3.76
(KJ/cycle)

Cycle 149 GMT 5/ 9/2024 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 33 14.99 473 234 0.23 / 559.43 2 3
2 12 1329.32 2 15.23 2140 65 0.30 / 559.50 2 2
3 7 2004.24 31 14.90 2907 1343 1.64 / 560.84 2 3
4 13 1581.20 19 14.88 2375 671 2.31 / 561.51 2 3
5 13 1014.36 19 14.92 1641 465 2.78 / 561.98 2 3
6 13 299.76 19 15.03 682 195 2.97 / 562.17 2 3
7 8 0.28 175 15.04 294 774 3.75 / 562.95 2 3
8 14 0.28 20 15.02 298 90 3.84 / 563.04 2 5
Average= 3.75
(KJ/cycle)

Cycle 148 GMT 26/ 8/2024 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 33 14.98 472 233 0.23 / 555.48 2 2
2 12 1162.40 2 15.26 1910 58 0.29 / 555.54 2 2
3 7 2006.04 31 14.90 2905 1342 1.63 / 556.88 2 2
4 13 1586.64 19 14.89 2390 676 2.31 / 557.56 2 2
5 13 1009.04 19 14.92 1636 464 2.77 / 558.02 2 4
6 13 284.40 19 15.03 666 190 2.96 / 558.21 2 3
7 13 84.08 19 15.07 398 114 3.08 / 558.33 2 3
8 8 -0.32 175 15.04 297 782 3.86 / 559.11 2 5
9 14 -0.32 20 15.02 300 90 3.95 / 559.20 2 4
Average= 3.75
(KJ/cycle)

Cycle 147 GMT 16/ 8/2024 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 33 14.98 455 225 0.22 / 551.73 2 2
2 12 1163.48 2 15.26 1900 58 0.28 / 551.79 2 2
3 7 2003.72 32 14.90 2908 1387 1.67 / 553.18 2 3
4 13 1584.08 19 14.88 2379 673 2.34 / 553.85 2 4
5 13 1007.24 19 14.91 1633 463 2.80 / 554.31 2 4
6 13 278.76 19 15.03 656 187 2.99 / 554.50 2 3
7 8 0.32 175 15.04 284 747 3.74 / 555.25 2 4
Average= 3.75
(KJ/cycle)

Cycle 146 GMT 6/ 8/2024 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 33 14.99 482 238 0.24 / 547.77 2 3
2 12 1302.84 2 15.22 2098 64 0.30 / 547.83 2 2
3 7 2008.12 31 14.92 2906 1344 1.65 / 549.18 2 3
4 13 1603.84 19 14.88 2411 682 2.33 / 549.86 2 3
5 13 1030.56 19 14.91 1659 470 2.80 / 550.33 2 3
6 13 445.96 19 14.99 882 251 3.05 / 550.58 2 3
7 13 18.04 19 15.07 304 87 3.14 / 550.67 2 3
8 8 -0.08 175 15.03 287 755 3.89 / 551.42 2 3
9 14 -0.08 20 15.01 290 87 3.98 / 551.51 2 3
Average= 3.75
(KJ/cycle)

Cycle 145 GMT 28/ 7/2024 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 33 14.99 459 227 0.23 / 543.99 2 2
2 12 1311.32 2 15.25 2101 64 0.29 / 544.05 2 2
3 7 2004.44 31 14.92 2904 1343 1.63 / 545.39 2 3
4 13 1598.20 19 14.88 2398 678 2.31 / 546.07 2 5
5 13 1039.08 19 14.92 1674 475 2.79 / 546.55 2 6
6 13 319.64 19 15.03 720 206 2.99 / 546.75 2 3
7 8 0.24 175 15.04 296 779 3.77 / 547.53 2 6
Average= 3.75
(KJ/cycle)

Cycle 144 GMT 18/ 7/2024 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 33 15.00 457 226 0.23 / 540.13 2 3
2 12 1161.24 2 15.27 1897 58 0.28 / 540.18 2 2
3 7 2006.16 32 14.91 2904 1386 1.67 / 541.57 2 3
4 13 1589.04 19 14.90 2391 677 2.35 / 542.25 2 4
5 13 1010.80 19 14.93 1640 465 2.81 / 542.71 2 3
6 13 284.92 19 15.02 687 196 3.01 / 542.91 2 3
7 13 29.08 19 15.07 332 95 3.10 / 543.00 2 2
8 8 0.00 175 15.04 288 758 3.86 / 543.76 2 6
Average= 3.75
(KJ/cycle)

Cycle 143 GMT 8/ 7/2024 14:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 33 14.99 457 226 0.23 / 536.39 2 3
2 12 1161.20 2 15.28 1911 58 0.28 / 536.45 2 2
3 7 2006.20 31 14.92 2900 1341 1.63 / 537.79 2 3
4 13 1591.20 19 14.89 2393 677 2.30 / 538.47 2 3
5 13 1019.76 19 14.93 1656 470 2.77 / 538.94 2 5
6 13 286.72 19 15.05 688 197 2.97 / 539.14 2 2
7 8 -0.20 175 15.06 289 762 3.73 / 539.90 2 4
Average= 3.75
(KJ/cycle)

Cycle 142 GMT 28/ 6/2024 19: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 15.02 462 229 0.23 / 532.63 2 2
2 12 1301.12 2 15.23 2099 64 0.29 / 532.70 2 2
3 7 2008.08 31 14.91 2911 1345 1.64 / 534.04 2 3
4 13 1595.28 19 14.89 2402 680 2.32 / 534.72 2 3
5 13 1022.00 19 14.94 1650 468 2.79 / 535.19 2 4
6 13 288.76 19 15.05 691 198 2.98 / 535.39 2 3
7 8 0.36 175 15.05 297 782 3.77 / 536.17 2 3
Average= 3.75
(KJ/cycle)

Cycle 141 GMT 18/ 6/2024 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 14.99 468 232 0.23 / 528.90 2 2
2 12 1317.20 2 15.25 2096 64 0.30 / 528.96 2 2
3 7 2002.76 31 14.92 2900 1341 1.64 / 530.30 2 3
4 13 1585.24 19 14.89 2384 674 2.31 / 530.98 2 3
5 13 1017.64 19 14.94 1643 466 2.78 / 531.44 2 3
6 13 296.72 19 15.05 682 195 2.97 / 531.64 2 3
7 8 0.12 175 15.06 290 764 3.74 / 532.40 2 3
Average= 3.75
(KJ/cycle)

Cycle 140 GMT 9/ 6/2024 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 33 15.00 486 241 0.24 / 525.14 2 2
2 12 1304.40 2 15.24 2098 64 0.30 / 525.20 2 2
3 7 2011.60 31 14.91 2906 1343 1.65 / 526.54 2 2
4 13 1599.48 19 14.89 2407 681 2.33 / 527.23 2 2
5 13 1020.64 19 14.91 1661 471 2.80 / 527.70 2 4
6 13 288.00 19 15.03 691 197 3.00 / 527.89 2 3
7 8 0.32 175 15.05 293 772 3.77 / 528.67 2 4
Average= 3.75
(KJ/cycle)

Cycle 139 GMT 30/ 5/2024 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 33 15.00 484 240 0.24 / 521.25 2 3
2 12 1306.96 2 15.24 2091 64 0.30 / 521.31 2 2
3 7 2005.56 31 14.92 2901 1342 1.65 / 522.66 2 3
4 13 1596.32 19 14.91 2406 682 2.33 / 523.34 2 3
5 13 1021.96 19 14.93 1659 471 2.80 / 523.81 2 5
6 13 295.84 19 15.04 714 204 3.00 / 524.01 2 3
7 8 -0.20 175 15.05 302 795 3.80 / 524.81 2 3
8 14 -0.20 20 15.03 299 90 3.89 / 524.90 2 9
Average= 3.75
(KJ/cycle)

Cycle 138 GMT 20/ 5/2024 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 33 15.00 472 234 0.23 / 517.47 2 3
2 12 1325.72 2 15.24 2124 65 0.30 / 517.53 2 2
3 7 2004.48 31 14.93 2909 1346 1.64 / 518.88 2 2
4 13 1593.96 19 14.90 2389 676 2.32 / 519.56 2 4
5 13 1034.44 19 14.93 1667 473 2.79 / 520.03 2 4
6 13 317.76 19 15.04 709 203 3.00 / 520.23 2 3
7 8 0.00 175 15.06 295 777 3.77 / 521.01 2 3
Average= 3.75
(KJ/cycle)

Cycle 137 GMT 10/ 5/2024 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 33 14.98 471 233 0.23 / 513.65 2 2
2 12 1320.68 2 15.24 2123 65 0.30 / 513.72 2 2
3 7 2003.60 32 14.92 2905 1387 1.68 / 515.10 2 3
4 13 1586.88 19 14.90 2397 679 2.36 / 515.78 2 2
5 13 1138.08 19 14.92 1802 511 2.87 / 516.29 2 6
6 13 251.00 19 15.06 620 177 3.05 / 516.47 2 3
7 8 -0.08 175 15.05 291 766 3.82 / 517.24 2 4
Average= 3.75
(KJ/cycle)

Cycle 136 GMT 30/ 4/2024 23:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 33 14.98 476 235 0.24 / 509.88 2 2
2 12 1324.16 2 15.24 2138 65 0.30 / 509.95 2 2
3 7 2010.68 31 14.91 2910 1345 1.65 / 511.29 2 4
4 13 1609.60 19 14.89 2418 684 2.33 / 511.98 2 3
5 13 1030.00 19 14.93 1661 471 2.80 / 512.45 2 4
6 13 290.68 19 15.03 670 191 2.99 / 512.64 2 3
7 8 0.48 175 15.05 296 780 3.77 / 513.42 2 2
Average= 3.75
(KJ/cycle)

Cycle 135 GMT 21/ 4/2024 4:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 33 14.98 451 223 0.22 / 506.04 2 2
2 12 1162.16 2 15.28 1907 58 0.28 / 506.10 2 2
3 7 2004.88 31 14.91 2904 1342 1.62 / 507.44 2 3
4 13 1575.80 19 14.89 2371 671 2.29 / 508.12 2 4
5 13 1011.36 19 14.92 1638 464 2.76 / 508.58 2 4
6 13 294.48 19 15.03 676 193 2.95 / 508.77 2 3
7 13 24.52 19 15.08 304 87 3.04 / 508.86 2 2
8 8 -0.04 175 15.04 299 787 3.83 / 509.65 2 4
Average= 3.75
(KJ/cycle)

Cycle 134 GMT 11/ 4/2024 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 33 15.00 454 225 0.22 / 502.16 2 2
2 12 1318.96 2 15.23 2127 65 0.29 / 502.23 2 2
3 7 2006.32 32 14.92 2917 1393 1.68 / 503.62 2 3
4 13 1582.52 19 14.89 2401 679 2.36 / 504.30 2 2
5 13 1011.20 19 14.91 1663 471 2.83 / 504.77 2 3
6 13 277.24 19 15.04 683 195 3.03 / 504.96 2 3
7 13 24.68 19 15.08 327 94 3.12 / 505.06 2 2
8 8 0.16 175 15.04 290 763 3.88 / 505.82 2 3
Average= 3.75
(KJ/cycle)

Cycle 133 GMT 1/ 4/2024 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 33 15.01 463 229 0.23 / 498.18 2 2
2 12 1319.92 2 15.22 2124 65 0.29 / 498.24 2 2
3 7 2011.72 31 14.91 2916 1348 1.64 / 499.59 2 2
4 13 1602.12 19 14.89 2412 682 2.32 / 500.27 2 3
5 13 1024.00 19 14.92 1674 475 2.80 / 500.75 2 5
6 13 419.52 19 15.00 876 250 3.05 / 501.00 2 3
7 13 19.92 19 15.08 321 92 3.14 / 501.09 2 3
8 8 -0.04 175 15.05 289 761 3.90 / 501.85 2 5
9 14 -0.04 20 15.03 294 88 3.99 / 501.94 2 14
Average= 3.75
(KJ/cycle)

Cycle 132 GMT 22/ 3/2024 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 33 15.00 463 229 0.23 / 494.42 2 2
2 12 1326.00 2 15.26 2131 65 0.29 / 494.48 2 2
3 7 2009.32 31 14.93 2914 1349 1.64 / 495.83 2 3
4 13 1594.80 19 14.90 2407 681 2.32 / 496.51 2 4
5 13 1026.80 19 14.93 1663 472 2.80 / 496.99 2 5
6 13 306.76 19 15.05 696 199 3.00 / 497.19 2 3
7 8 0.04 175 15.06 289 762 3.76 / 497.95 2 5
Average= 3.74
(KJ/cycle)

Cycle 131 GMT 12/ 3/2024 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 33 15.00 468 232 0.23 / 490.61 2 3
2 12 1172.48 2 15.26 1905 58 0.29 / 490.67 2 2
3 7 2005.88 31 14.92 2922 1351 1.64 / 492.02 2 2
4 13 1610.32 19 14.90 2419 685 2.33 / 492.71 2 6
5 13 1165.88 19 14.91 1839 521 2.85 / 493.23 2 5
6 13 290.60 19 15.05 684 196 3.04 / 493.43 2 3
7 8 0.00 175 15.06 290 764 3.81 / 494.19 2 6
Average= 3.74
(KJ/cycle)

Cycle 130 GMT 3/ 3/2024 4:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 33 15.01 461 228 0.23 / 486.86 2 2
2 12 1322.40 2 15.25 2127 65 0.29 / 486.92 2 2
3 7 2009.68 31 14.92 2917 1349 1.64 / 488.27 2 2
4 13 1582.16 19 14.92 2385 676 2.32 / 488.95 2 4
5 13 1002.80 19 14.95 1647 468 2.79 / 489.41 2 3
6 13 272.20 19 15.05 672 192 2.98 / 489.61 2 3
7 8 0.28 175 15.06 295 777 3.76 / 490.38 2 5
Average= 3.74
(KJ/cycle)

Cycle 129 GMT 22/ 2/2024 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 33 15.01 478 237 0.24 / 482.98 2 2
2 12 1324.60 2 15.25 2132 65 0.30 / 483.05 2 2
3 7 2009.92 31 14.92 2912 1347 1.65 / 484.39 2 3
4 13 1589.68 19 14.91 2390 677 2.33 / 485.07 2 3
5 13 1015.68 19 14.94 1648 468 2.79 / 485.54 2 3
6 13 287.16 19 15.06 699 200 2.99 / 485.74 2 3
7 8 0.20 175 15.06 303 799 3.79 / 486.54 2 2
8 14 0.20 20 15.04 297 89 3.88 / 486.63 2 3
Average= 3.74
(KJ/cycle)

Cycle 128 GMT 12/ 2/2024 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 33 15.01 468 232 0.23 / 479.16 2 3
2 12 1306.20 2 15.25 2107 64 0.30 / 479.22 2 2
3 7 2006.76 31 14.92 2902 1342 1.64 / 480.56 2 3
4 13 1584.52 19 14.90 2380 674 2.31 / 481.24 2 5
5 13 1009.00 19 14.94 1643 466 2.78 / 481.70 2 4
6 13 285.88 19 15.06 669 191 2.97 / 481.89 2 3
7 8 0.16 175 15.07 288 760 3.73 / 482.65 2 2
8 14 0.16 20 15.05 304 92 3.82 / 482.75 2 4
Average= 3.74
(KJ/cycle)

Cycle 127 GMT 2/ 2/2024 18:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.01 482 232 0.23 / 475.29 2 3
2 12 1159.44 2 15.28 1898 58 0.29 / 475.35 2 2
3 7 2010.64 31 14.92 2914 1348 1.64 / 476.70 2 2
4 13 1579.12 19 14.92 2370 672 2.31 / 477.37 2 4
5 13 1007.28 19 14.95 1639 466 2.77 / 477.84 2 5
6 13 281.04 19 15.05 672 192 2.97 / 478.03 2 3
7 8 0.12 175 15.07 305 804 3.77 / 478.83 2 4
8 14 0.12 20 15.05 300 90 3.86 / 478.92 2 9
Average= 3.74
(KJ/cycle)

Cycle 126 GMT 23/ 1/2024 20:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 32 15.00 486 233 0.23 / 471.49 2 2
2 12 1164.64 2 15.29 1902 58 0.29 / 471.55 2 2
3 7 2003.84 32 14.93 2907 1389 1.68 / 472.94 2 3
4 13 1575.12 19 14.92 2375 673 2.35 / 473.61 2 3
5 13 1001.20 19 14.95 1634 464 2.82 / 474.07 2 3
6 13 274.00 19 15.06 681 195 3.01 / 474.27 2 3
7 8 -0.20 175 15.07 301 794 3.81 / 475.06 2 3
Average= 3.74
(KJ/cycle)

Cycle 125 GMT 13/ 1/2024 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 15.01 467 224 0.22 / 467.75 2 2
2 12 1160.48 2 15.27 1899 58 0.28 / 467.81 2 2
3 7 2006.40 31 14.90 2899 1339 1.62 / 469.15 2 3
4 13 1584.64 19 14.90 2380 674 2.30 / 469.82 2 6
5 13 1000.72 19 14.94 1628 462 2.76 / 470.28 2 5
6 13 278.40 19 15.06 658 188 2.95 / 470.47 2 3
7 8 0.20 175 15.07 298 786 3.73 / 471.26 2 3
Average= 3.74
(KJ/cycle)

Cycle 124 GMT 4/ 1/2024 1: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 15.02 493 237 0.24 / 464.03 2 2
2 12 1163.36 2 15.29 1913 58 0.30 / 464.08 2 2
3 7 2003.08 31 14.93 2907 1345 1.64 / 465.43 2 2
4 13 1579.44 19 14.91 2380 674 2.32 / 466.10 2 5
5 13 1003.76 19 14.95 1637 465 2.78 / 466.57 2 3
6 13 267.00 19 15.07 642 184 2.96 / 466.75 2 2
7 8 0.24 175 15.08 293 773 3.74 / 467.53 2 3
Average= 3.74
(KJ/cycle)

Cycle 123 GMT 25/12/2023 3:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 15.02 469 225 0.23 / 460.26 2 3
2 12 1321.68 2 15.26 2148 66 0.29 / 460.32 2 2
3 7 2007.84 31 14.93 2912 1348 1.64 / 461.67 2 2
4 13 1583.60 19 14.91 2384 675 2.31 / 462.35 2 4
5 13 1009.04 19 14.96 1648 468 2.78 / 462.82 2 5
6 13 281.28 19 15.07 665 190 2.97 / 463.01 2 3
7 8 0.32 175 15.09 296 782 3.75 / 463.79 2 7
Average= 3.74
(KJ/cycle)

Cycle 122 GMT 15/12/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 32 15.01 475 228 0.23 / 456.45 2 2
2 12 1312.08 2 15.24 2112 64 0.29 / 456.51 2 2
3 7 2006.08 31 14.95 2900 1344 1.64 / 457.85 2 3
4 13 1603.88 19 14.90 2412 683 2.32 / 458.54 2 5
5 13 1041.36 19 14.94 1682 477 2.80 / 459.01 2 3
6 13 322.52 19 15.05 716 205 3.00 / 459.22 2 3
7 8 -0.12 175 15.07 309 815 3.82 / 460.03 2 2
Average= 3.74
(KJ/cycle)

Cycle 121 GMT 5/12/2023 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 15.02 480 231 0.23 / 452.64 2 2
2 12 1315.64 2 15.25 2124 65 0.30 / 452.71 2 2
3 7 2004.60 31 14.93 2907 1345 1.64 / 454.05 2 2
4 13 1588.56 19 14.91 2395 678 2.32 / 454.73 2 2
5 13 1012.08 19 14.96 1646 468 2.79 / 455.20 2 4
6 13 283.48 19 15.07 667 191 2.98 / 455.39 2 3
7 8 -0.12 175 15.09 279 737 3.72 / 456.13 2 3
8 14 -0.12 20 15.06 303 91 3.81 / 456.22 2 4
Average= 3.74
(KJ/cycle)

Cycle 120 GMT 25/11/2023 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 15.03 463 223 0.22 / 448.88 2 3
2 12 1158.32 2 15.29 1908 58 0.28 / 448.94 2 2
3 7 2003.68 31 14.93 2904 1344 1.63 / 450.29 2 3
4 13 1584.40 19 14.91 2384 675 2.30 / 450.96 2 3
5 13 1006.52 19 14.94 1635 464 2.76 / 451.43 2 3
6 13 268.44 19 15.07 646 185 2.95 / 451.61 2 3
7 8 0.28 175 15.08 303 800 3.75 / 452.41 2 6
Average= 3.74
(KJ/cycle)

Cycle 119 GMT 15/11/2023 11:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 32 15.04 484 233 0.23 / 445.03 2 2
2 12 1318.44 2 15.25 2128 65 0.30 / 445.10 2 2
3 7 2003.16 31 14.93 2908 1346 1.64 / 446.44 2 3
4 13 1577.88 19 14.92 2389 677 2.32 / 447.12 2 3
5 13 1003.80 19 14.96 1636 465 2.79 / 447.58 2 6
6 13 402.92 19 15.05 829 237 3.02 / 447.82 2 3
7 8 -0.16 175 15.09 284 750 3.77 / 448.57 2 3
8 14 -0.16 20 15.07 300 90 3.86 / 448.66 2 3
Average= 3.74
(KJ/cycle)

Cycle 118 GMT 5/11/2023 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 32 15.03 476 229 0.23 / 441.32 2 2
2 12 1315.72 2 15.24 2123 65 0.29 / 441.38 2 2
3 7 2002.04 31 14.93 2908 1346 1.64 / 442.73 2 3
4 13 1579.92 19 14.92 2380 675 2.31 / 443.40 2 2
5 13 1008.16 19 14.95 1637 465 2.78 / 443.87 2 2
6 13 276.72 19 15.09 658 189 2.97 / 444.06 2 3
7 8 0.00 175 15.10 280 740 3.71 / 444.80 2 3
Average= 3.74
(KJ/cycle)

Cycle 117 GMT 26/10/2023 15:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 32 15.03 468 225 0.23 / 437.51 2 2
2 12 1157.08 2 15.29 1903 58 0.28 / 437.57 2 2
3 7 2004.28 32 14.93 2903 1387 1.67 / 438.96 2 2
4 13 1574.68 19 14.92 2373 673 2.34 / 439.63 2 3
5 13 1002.80 19 14.96 1633 464 2.81 / 440.10 2 3
6 13 283.72 19 15.07 668 191 3.00 / 440.29 2 3
7 8 0.36 175 15.08 304 802 3.80 / 441.09 2 5
Average= 3.74
(KJ/cycle)

Cycle 116 GMT 16/10/2023 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 32 15.04 473 228 0.23 / 433.67 2 2
2 12 1159.12 2 15.29 1905 58 0.29 / 433.73 2 2
3 7 2006.92 31 14.93 2916 1350 1.64 / 435.07 2 2
4 13 1474.48 19 14.94 2248 638 2.27 / 435.71 2 3
5 13 1052.68 19 14.95 1699 483 2.76 / 436.20 2 5
6 13 312.36 19 15.07 710 203 2.96 / 436.40 2 3
7 8 -0.08 175 15.08 303 800 3.76 / 437.20 2 2
8 14 -0.08 20 15.06 304 92 3.85 / 437.29 2 4
Average= 3.74
(KJ/cycle)

Cycle 115 GMT 6/10/2023 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 32 15.02 491 236 0.24 / 429.85 2 2
2 12 1159.96 2 15.28 1905 58 0.29 / 429.90 2 2
3 7 2002.76 31 14.93 2905 1345 1.64 / 431.25 2 3
4 13 1579.24 19 14.92 2378 674 2.31 / 431.92 2 4
5 13 1007.88 19 14.96 1640 466 2.78 / 432.39 2 3
6 13 277.52 19 15.08 662 190 2.97 / 432.58 2 3
7 8 0.40 175 15.09 291 768 3.74 / 433.35 2 3
8 14 0.40 20 15.07 305 92 3.83 / 433.44 3 4
Average= 3.74
(KJ/cycle)

Cycle 114 GMT 26/ 9/2023 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 32 15.04 488 235 0.23 / 425.97 2 2
2 12 1314.72 2 15.25 2133 65 0.30 / 426.04 2 2
3 7 2005.00 31 14.94 2904 1345 1.64 / 427.38 2 2
4 13 1585.36 19 14.92 2392 678 2.32 / 428.06 2 3
5 13 1019.68 19 14.96 1651 469 2.79 / 428.53 2 4
6 13 302.16 19 15.05 696 199 2.99 / 428.73 2 3
7 8 2.36 175 15.09 298 787 3.78 / 429.52 2 3
8 14 2.36 20 15.06 314 95 3.87 / 429.61 2 3
Average= 3.74
(KJ/cycle)

Cycle 113 GMT 17/ 9/2023 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 32 15.04 477 230 0.23 / 422.16 2 3
2 12 1323.68 2 15.24 2151 66 0.30 / 422.23 2 2
3 7 2004.68 31 14.93 2908 1346 1.64 / 423.57 2 3
4 13 1582.28 19 14.92 2391 678 2.32 / 424.25 2 7
5 13 998.48 19 14.96 1631 464 2.78 / 424.71 2 3
6 13 265.16 19 15.08 650 186 2.97 / 424.90 2 3
7 8 1.48 175 15.09 281 742 3.71 / 425.64 2 3
8 14 1.48 20 15.07 313 94 3.81 / 425.74 2 3
Average= 3.73
(KJ/cycle)

Cycle 112 GMT 7/ 9/2023 1:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 32 15.03 474 228 0.23 / 418.37 2 2
2 12 1309.08 2 15.25 2109 64 0.29 / 418.43 2 2
3 7 2005.36 31 14.95 2910 1349 1.64 / 419.78 2 3
4 13 1588.24 19 14.92 2390 678 2.32 / 420.46 2 5
5 13 1010.20 19 14.97 1642 467 2.79 / 420.93 2 3
6 13 412.24 19 15.05 843 241 3.03 / 421.17 2 3
7 8 0.28 175 15.09 290 766 3.79 / 421.93 2 3
Average= 3.73
(KJ/cycle)

Cycle 111 GMT 28/ 8/2023 3:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 32 15.03 486 234 0.23 / 414.57 2 3
2 12 1167.68 2 15.30 1913 59 0.29 / 414.63 2 2
3 7 2005.80 31 14.94 2918 1351 1.64 / 415.98 2 2
4 13 1577.60 19 14.93 2403 682 2.33 / 416.66 2 5
5 13 1005.28 19 14.95 1680 477 2.80 / 417.14 2 3
6 13 274.80 19 15.08 685 196 3.00 / 417.34 2 3
7 8 0.12 175 15.09 304 803 3.80 / 418.14 2 3
Average= 3.73
(KJ/cycle)

Cycle 110 GMT 18/ 8/2023 6: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 32 15.03 473 227 0.23 / 410.53 2 2
2 12 1157.72 2 15.30 1902 58 0.29 / 410.58 2 2
3 7 2007.80 31 14.94 2913 1349 1.63 / 411.93 2 4
4 13 1591.16 19 14.93 2407 683 2.32 / 412.62 2 3
5 13 1013.68 19 14.97 1650 469 2.79 / 413.09 2 4
6 13 416.28 19 15.04 856 245 3.03 / 413.33 2 3
7 13 16.88 19 15.12 305 88 3.12 / 413.42 2 2
8 8 -0.04 175 15.08 313 826 3.95 / 414.24 2 5
9 14 -0.04 20 15.06 312 94 4.04 / 414.34 2 4
Average= 3.73
(KJ/cycle)

Cycle 109 GMT 8/ 8/2023 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 15.04 480 231 0.23 / 406.62 2 2
2 12 1161.24 2 15.30 1906 58 0.29 / 406.68 2 2
3 7 2007.48 31 14.94 2919 1352 1.64 / 408.03 2 2
4 13 1478.12 19 14.93 2295 651 2.29 / 408.68 2 3
5 13 1049.52 19 14.95 1733 492 2.78 / 409.17 2 3
6 13 311.12 19 15.07 745 213 3.00 / 409.39 2 3
7 8 0.52 175 15.08 310 818 3.82 / 410.21 2 5
8 14 0.52 20 15.05 309 93 3.91 / 410.30 2 4
Average= 3.73
(KJ/cycle)

Cycle 108 GMT 29/ 7/2023 10:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 32 15.04 473 228 0.23 / 402.71 2 2
2 12 1164.08 2 15.30 1908 58 0.29 / 402.77 2 2
3 7 2003.44 32 14.94 2907 1390 1.68 / 404.16 2 2
4 13 1584.12 19 14.93 2398 680 2.36 / 404.84 2 3
5 13 1008.36 19 14.97 1643 467 2.82 / 405.31 2 3
6 13 269.80 19 15.07 654 187 3.01 / 405.49 2 3
7 8 0.20 175 15.08 304 802 3.81 / 406.30 2 6
8 14 0.20 20 15.06 309 93 3.91 / 406.39 2 3
Average= 3.73
(KJ/cycle)

Cycle 107 GMT 19/ 7/2023 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 15.03 478 230 0.23 / 398.81 2 3
2 12 1318.64 2 15.25 2128 65 0.29 / 398.87 2 2
3 7 2003.20 31 14.94 2919 1352 1.65 / 400.22 2 2
4 13 1585.08 19 14.91 2420 686 2.33 / 400.91 2 4
5 13 1006.96 19 14.95 1682 478 2.81 / 401.39 2 3
6 13 278.76 19 15.08 691 198 3.01 / 401.58 2 3
7 8 -0.04 175 15.09 306 808 3.82 / 402.39 2 3
8 14 -0.04 20 15.06 303 91 3.91 / 402.48 2 2
Average= 3.73
(KJ/cycle)

Cycle 106 GMT 9/ 7/2023 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 15.02 469 225 0.23 / 394.93 2 3
2 12 1157.64 2 15.30 1907 58 0.28 / 394.99 2 2
3 7 2008.76 32 14.94 2909 1391 1.67 / 396.38 2 4
4 13 1574.32 19 14.93 2379 675 2.35 / 397.05 2 2
5 13 994.72 19 14.98 1616 460 2.81 / 397.51 2 4
6 13 405.12 19 15.06 838 240 3.05 / 397.75 2 3
7 8 0.08 175 15.08 312 823 3.87 / 398.58 2 4
Average= 3.73
(KJ/cycle)

Cycle 105 GMT 29/ 6/2023 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 15.04 466 224 0.22 / 391.10 2 2
2 12 1156.08 2 15.30 1908 58 0.28 / 391.15 2 2
3 7 2003.36 31 14.93 2913 1348 1.63 / 392.50 2 2
4 13 1580.52 19 14.92 2386 676 2.31 / 393.18 2 4
5 13 997.92 19 14.96 1627 462 2.77 / 393.64 2 3
6 13 276.08 19 15.07 661 189 2.96 / 393.83 2 3
7 8 -0.04 175 15.09 296 782 3.74 / 394.61 2 7
8 14 -0.04 20 15.07 307 93 3.83 / 394.70 2 7
Average= 3.72
(KJ/cycle)

Cycle 104 GMT 19/ 6/2023 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 32 15.04 467 225 0.22 / 387.28 2 3
2 12 1153.64 2 15.30 1890 58 0.28 / 387.34 2 2
3 7 2003.80 31 14.94 2911 1348 1.63 / 388.68 2 3
4 13 1467.72 19 14.94 2243 637 2.27 / 389.32 2 5
5 13 1032.92 19 14.97 1680 478 2.75 / 389.80 2 4
6 13 287.88 19 15.08 681 195 2.94 / 389.99 2 3
7 8 0.32 175 15.09 297 784 3.72 / 390.78 2 5
8 14 0.32 20 15.07 307 93 3.82 / 390.87 2 4
Average= 3.72
(KJ/cycle)

Cycle 103 GMT 9/ 6/2023 20:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 32 15.05 484 233 0.23 / 383.29 2 3
2 12 1148.36 2 15.30 1902 58 0.29 / 383.35 2 2
3 7 2003.80 31 14.94 2918 1351 1.64 / 384.70 2 3
4 13 1578.60 19 14.93 2391 678 2.32 / 385.38 2 3
5 13 999.40 19 14.97 1633 464 2.79 / 385.85 2 5
6 13 273.56 19 15.07 689 197 2.98 / 386.04 2 3
7 13 68.88 19 15.11 409 117 3.10 / 386.16 2 3
8 8 0.08 175 15.08 304 802 3.90 / 386.96 2 3
9 14 0.08 20 15.06 301 91 3.99 / 387.05 2 3
Average= 3.72
(KJ/cycle)

Cycle 102 GMT 30/ 5/2023 22:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 15.03 466 224 0.22 / 379.36 2 3
2 12 1308.76 2 15.26 2135 65 0.29 / 379.43 2 2
3 7 2003.96 31 14.94 2919 1352 1.64 / 380.78 2 3
4 13 1578.16 19 14.92 2394 679 2.32 / 381.46 2 4
5 13 997.08 19 14.96 1638 466 2.79 / 381.93 2 5
6 13 398.84 19 15.05 837 239 3.02 / 382.16 2 3
7 8 -0.04 175 15.09 304 803 3.83 / 382.97 2 4
8 14 -0.04 20 15.07 310 93 3.92 / 383.06 2 6
Average= 3.72
(KJ/cycle)

Cycle 101 GMT 21/ 5/2023 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 32 15.02 471 226 0.23 / 375.46 2 3
2 12 1313.52 2 15.24 2112 64 0.29 / 375.52 2 2
3 7 2006.32 31 14.94 2921 1353 1.64 / 376.88 2 3
4 13 1591.24 19 14.93 2410 684 2.33 / 377.56 2 5
5 13 1013.56 19 14.96 1652 470 2.80 / 378.03 2 3
6 13 292.20 19 15.08 700 201 3.00 / 378.23 2 3
7 8 0.40 175 15.09 309 816 3.81 / 379.05 2 5
8 14 0.40 20 15.06 310 93 3.91 / 379.14 2 4
Average= 3.72
(KJ/cycle)

Cycle 100 GMT 11/ 5/2023 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 32 15.03 509 245 0.24 / 371.47 2 2
2 12 1328.68 2 15.25 2157 66 0.31 / 371.54 2 2
3 7 2005.44 32 14.93 2916 1393 1.70 / 372.93 2 3
4 13 1575.64 19 14.92 2389 677 2.38 / 373.61 2 5
5 13 994.16 19 14.97 1627 463 2.84 / 374.07 2 3
6 13 271.20 19 15.08 654 187 3.03 / 374.26 2 3
7 13 22.52 19 15.12 305 88 3.12 / 374.34 2 3
8 8 0.16 175 15.08 301 794 3.91 / 375.14 2 11
9 14 0.16 20 15.05 313 94 4.01 / 375.23 2 4
Average= 3.72
(KJ/cycle)

Cycle 99 GMT 1/ 5/2023 4:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 32 15.04 467 225 0.22 / 367.65 2 3
2 12 1321.48 2 15.26 2138 65 0.29 / 367.71 2 2
3 7 2007.80 31 14.93 2926 1354 1.64 / 369.07 2 3
4 13 1579.92 19 14.93 2395 679 2.32 / 369.75 2 5
5 13 1003.96 19 14.96 1638 466 2.79 / 370.21 2 3
6 13 264.60 19 15.10 646 185 2.97 / 370.40 2 3
7 8 -0.12 175 15.09 314 829 3.80 / 371.23 2 3
Average= 3.71
(KJ/cycle)

Cycle 98 GMT 21/ 4/2023 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 32 15.04 464 223 0.22 / 363.71 2 3
2 12 1306.28 2 15.27 2158 66 0.29 / 363.78 2 2
3 7 2003.24 32 14.94 2923 1397 1.69 / 365.17 2 3
4 13 1575.08 19 14.93 2397 680 2.37 / 365.85 2 7
5 13 997.16 19 14.97 1639 466 2.83 / 366.32 2 3
6 13 274.40 19 15.09 661 190 3.02 / 366.51 2 3
7 8 0.36 175 15.09 310 819 3.84 / 367.33 2 2
8 14 0.36 20 15.08 310 93 3.93 / 367.42 2 4
Average= 3.71
(KJ/cycle)

Cycle 97 GMT 11/ 4/2023 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 32 15.04 486 234 0.23 / 359.93 2 3
2 12 1160.00 2 15.30 1909 58 0.29 / 359.99 2 2
3 7 2003.96 31 14.93 2916 1350 1.64 / 361.33 2 3
4 13 1578.92 19 14.92 2399 680 2.32 / 362.02 2 2
5 13 998.40 19 14.97 1640 466 2.79 / 362.48 2 3
6 13 271.96 19 15.09 654 188 2.98 / 362.67 2 3
7 8 -0.08 175 15.09 310 819 3.79 / 363.49 2 3
Average= 3.71
(KJ/cycle)

Cycle 96 GMT 1/ 4/2023 10:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 32 15.04 480 231 0.23 / 356.03 2 3
2 12 1327.24 2 15.27 2196 67 0.30 / 356.10 2 2
3 7 2004.68 31 14.94 2933 1358 1.66 / 357.46 2 4
4 13 1580.92 19 14.93 2404 682 2.34 / 358.14 2 3
5 13 1003.12 19 14.98 1649 469 2.81 / 358.61 2 5
6 13 265.88 19 15.10 650 186 2.99 / 358.80 2 3
7 8 -0.08 175 15.09 304 803 3.80 / 359.60 2 4
8 14 -0.08 20 15.07 310 93 3.89 / 359.69 2 3
Average= 3.71
(KJ/cycle)

Cycle 95 GMT 22/ 3/2023 12:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 32 15.03 481 231 0.23 / 352.27 2 3
2 12 1164.00 2 15.31 1933 59 0.29 / 352.33 2 2
3 7 2005.56 31 14.94 2927 1356 1.65 / 353.68 2 4
4 13 1585.36 19 14.92 2402 681 2.33 / 354.37 2 3
5 13 998.12 19 14.97 1644 468 2.79 / 354.83 2 3
6 13 257.32 19 15.09 636 182 2.98 / 355.02 2 3
7 8 0.24 175 15.10 298 787 3.76 / 355.80 2 3
Average= 3.71
(KJ/cycle)

Cycle 94 GMT 12/ 3/2023 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 32 15.02 480 231 0.23 / 348.45 2 2
2 12 1319.56 2 15.26 2170 66 0.30 / 348.52 2 2
3 7 2002.84 32 14.94 2928 1400 1.70 / 349.92 2 2
4 13 1582.40 19 14.93 2401 681 2.38 / 350.60 2 6
5 13 999.68 19 14.98 1639 466 2.84 / 351.06 2 4
6 13 269.64 19 15.09 653 187 3.03 / 351.25 2 3
7 8 0.28 175 15.09 298 787 3.82 / 352.04 2 3
Average= 3.71
(KJ/cycle)

Cycle 93 GMT 2/ 3/2023 17: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 32 15.03 481 231 0.23 / 344.65 2 3
2 12 1317.80 2 15.26 2158 66 0.30 / 344.72 2 2
3 7 2005.84 31 14.92 2920 1351 1.65 / 346.07 2 3
4 13 1579.08 19 14.92 2396 679 2.33 / 346.75 2 6
5 13 988.60 19 14.96 1628 463 2.79 / 347.21 2 5
6 13 256.32 19 15.09 638 183 2.97 / 347.39 2 3
7 8 -0.04 175 15.08 314 829 3.80 / 348.22 2 3
Average= 3.70
(KJ/cycle)

Cycle 92 GMT 20/ 2/2023 19:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 32 15.05 491 236 0.24 / 340.88 2 2
2 12 1314.84 2 15.26 2140 65 0.30 / 340.94 2 2
3 7 2003.68 31 14.93 2920 1351 1.65 / 342.29 2 4
4 13 1466.96 19 14.93 2249 638 2.29 / 342.93 2 4
5 13 1030.12 19 14.95 1675 476 2.77 / 343.41 2 5
6 13 275.64 19 15.08 668 191 2.96 / 343.60 2 2
7 8 0.48 175 15.09 310 819 3.78 / 344.42 2 3
Average= 3.70
(KJ/cycle)

Cycle 91 GMT 10/ 2/2023 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 15.05 480 231 0.23 / 337.07 2 3
2 12 1308.08 2 15.26 2129 65 0.30 / 337.14 2 2
3 7 2004.24 31 14.95 2914 1350 1.65 / 338.49 2 3
4 13 1571.84 19 14.94 2388 678 2.32 / 339.16 2 3
5 13 997.52 19 14.99 1636 466 2.79 / 339.63 2 4
6 13 266.12 19 15.09 651 187 2.98 / 339.82 2 3
7 8 0.00 175 15.10 312 824 3.80 / 340.64 2 3
Average= 3.70
(KJ/cycle)

Cycle 90 GMT 31/ 1/2023 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 32 15.05 477 230 0.23 / 333.09 2 3
2 12 1311.60 2 15.27 2143 65 0.30 / 333.16 2 2
3 7 2003.36 31 14.96 2918 1353 1.65 / 334.51 2 3
4 13 1579.12 19 14.94 2394 680 2.33 / 335.19 2 3
5 13 1124.76 19 14.97 1809 515 2.84 / 335.70 2 5
6 13 358.20 19 15.08 779 223 3.07 / 335.93 2 3
7 8 0.08 175 15.11 309 817 3.88 / 336.74 2 4
8 14 0.08 20 15.09 319 96 3.98 / 336.84 2 5
Average= 3.70
(KJ/cycle)

Cycle 89 GMT 22/ 1/2023 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 32 15.06 487 235 0.23 / 329.35 2 3
2 12 1310.96 2 15.28 2152 66 0.30 / 329.42 2 2
3 7 2007.88 31 14.94 2917 1351 1.65 / 330.77 2 3
4 13 1576.16 19 14.94 2384 677 2.33 / 331.45 2 6
5 13 990.52 19 14.98 1623 462 2.79 / 331.91 2 3
6 13 252.36 19 15.11 629 181 2.97 / 332.09 2 3
7 8 0.24 175 15.11 292 772 3.74 / 332.86 2 3
Average= 3.70
(KJ/cycle)

Cycle 88 GMT 12/ 1/2023 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 15.06 471 227 0.23 / 325.61 2 3
2 12 1309.92 2 15.27 2132 65 0.29 / 325.67 2 2
3 7 2005.96 31 14.96 2925 1356 1.65 / 327.03 2 4
4 13 1587.84 19 14.96 2405 684 2.33 / 327.71 2 3
5 13 1007.76 19 14.99 1650 470 2.80 / 328.18 2 4
6 13 280.84 19 15.11 670 192 2.99 / 328.37 2 3
7 8 0.16 175 15.12 281 744 3.74 / 329.12 2 5
Average= 3.70
(KJ/cycle)

Cycle 87 GMT 2/ 1/2023 5:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 32 15.06 484 233 0.23 / 321.76 2 3
2 12 1158.92 2 15.31 1923 59 0.29 / 321.82 2 2
3 7 2006.08 31 14.95 2916 1351 1.64 / 323.17 2 4
4 13 1570.92 19 14.95 2380 676 2.32 / 323.85 2 7
5 13 991.32 19 14.99 1631 465 2.78 / 324.31 2 4
6 13 259.36 19 15.11 640 184 2.97 / 324.50 2 3
7 8 0.24 175 15.11 299 791 3.76 / 325.29 2 3
8 14 0.24 20 15.08 308 93 3.85 / 325.38 2 4
Average= 3.70
(KJ/cycle)

Cycle 86 GMT 23/12/2022 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 32 15.07 491 237 0.24 / 318.00 2 3
2 12 1314.56 2 15.27 2143 65 0.30 / 318.06 2 2
3 7 2001.88 31 14.95 2914 1350 1.65 / 319.41 2 4
4 13 1571.72 19 14.95 2380 676 2.33 / 320.09 2 5
5 13 989.32 19 15.00 1624 463 2.79 / 320.55 2 5
6 13 253.12 19 15.11 633 182 2.97 / 320.73 2 3
7 8 -0.04 175 15.12 270 714 3.69 / 321.45 2 5
8 14 -0.04 20 15.09 269 81 3.77 / 321.53 2 4
Average= 3.70
(KJ/cycle)

Cycle 85 GMT 13/12/2022 9:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 32 15.07 490 236 0.24 / 314.25 2 2
2 12 1299.76 2 15.28 2122 65 0.30 / 314.31 2 2
3 7 2002.44 31 14.95 2913 1350 1.65 / 315.66 2 3
4 13 1569.72 19 14.94 2372 673 2.32 / 316.34 2 4
5 13 985.04 19 14.99 1621 462 2.79 / 316.80 2 4
6 13 259.60 19 15.11 639 183 2.97 / 316.98 2 3
7 8 0.24 175 15.12 294 778 3.75 / 317.76 2 4
Average= 3.69
(KJ/cycle)

Cycle 84 GMT 3/12/2022 11:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 32 15.07 488 235 0.24 / 310.49 2 3
2 12 1307.80 2 15.29 2142 66 0.30 / 310.55 2 2
3 7 2002.80 31 14.97 2919 1355 1.66 / 311.91 2 3
4 13 1586.12 19 14.96 2406 684 2.34 / 312.59 2 6
5 13 997.08 19 15.00 1642 468 2.81 / 313.06 2 3
6 13 268.32 19 15.13 656 189 3.00 / 313.25 2 3
7 8 0.20 175 15.14 288 763 3.76 / 314.01 2 3
Average= 3.69
(KJ/cycle)

Cycle 83 GMT 23/11/2022 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 32 15.08 486 235 0.23 / 306.74 2 2
2 12 1313.92 2 15.29 2156 66 0.30 / 306.81 2 2
3 7 2002.44 31 14.97 2913 1352 1.65 / 308.16 2 3
4 13 1568.80 19 14.96 2368 673 2.33 / 308.83 2 6
5 13 981.28 19 15.02 1616 461 2.79 / 309.29 2 4
6 13 251.32 19 15.13 628 181 2.97 / 309.47 2 3
7 8 0.08 175 15.14 294 779 3.75 / 310.25 2 5
Average= 3.69
(KJ/cycle)

Cycle 82 GMT 13/11/2022 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 15.09 477 230 0.23 / 302.87 2 2
2 12 1306.40 2 15.27 2144 65 0.30 / 302.94 2 2
3 7 2007.36 31 14.96 2922 1355 1.65 / 304.30 2 4
4 13 1584.40 19 14.95 2394 680 2.33 / 304.98 2 3
5 13 1003.68 19 15.00 1641 468 2.80 / 305.44 2 3
6 13 285.28 19 15.12 680 195 2.99 / 305.64 2 3
7 8 -0.08 175 15.13 293 776 3.77 / 306.41 2 4
8 14 -0.08 20 15.10 307 93 3.86 / 306.51 2 5
Average= 3.69
(KJ/cycle)

Cycle 81 GMT 3/11/2022 17:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 32 15.08 503 243 0.24 / 299.12 2 2
2 12 1155.72 2 15.33 1926 59 0.30 / 299.18 2 2
3 7 2006.20 31 14.95 2910 1349 1.65 / 300.52 2 3
4 13 1568.60 19 14.96 2382 677 2.33 / 301.20 2 2
5 13 975.56 19 15.01 1608 459 2.79 / 301.66 2 3
6 13 246.28 19 15.13 627 180 2.97 / 301.84 2 2
7 8 0.04 175 15.13 304 805 3.77 / 302.64 2 4
Average= 3.69
(KJ/cycle)

Cycle 80 GMT 24/10/2022 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 15.10 483 233 0.23 / 295.35 2 3
2 12 1296.28 2 15.30 2097 64 0.30 / 295.41 2 2
3 7 2003.64 31 14.97 2915 1353 1.65 / 296.76 2 2
4 13 1573.80 19 14.97 2393 681 2.33 / 297.45 2 3
5 13 987.52 19 15.01 1627 464 2.79 / 297.91 2 5
6 13 256.40 19 15.14 642 185 2.98 / 298.09 2 3
7 8 0.16 175 15.15 294 779 3.76 / 298.87 2 5
Average= 3.69
(KJ/cycle)

Cycle 79 GMT 14/10/2022 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 31 15.09 508 238 0.24 / 291.55 2 3
2 3 1017.76 1 15.24 1737 26 0.26 / 291.57 2 2
3 12 1160.40 2 15.33 1914 59 0.32 / 291.63 2 2
4 7 2007.24 31 14.98 2922 1357 1.68 / 292.99 2 4
5 13 1596.32 19 14.96 2413 686 2.37 / 293.68 2 5
6 13 1016.52 19 15.01 1659 473 2.84 / 294.15 2 4
7 13 288.76 19 15.13 685 197 3.04 / 294.35 2 3
8 8 0.04 175 15.15 290 769 3.80 / 295.11 2 4
Average= 3.69
(KJ/cycle)

Cycle 78 GMT 4/10/2022 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 31 15.10 491 230 0.23 / 287.67 2 2
2 12 1170.76 2 15.32 1922 59 0.29 / 287.72 2 2
3 7 2002.04 31 15.00 2919 1357 1.65 / 289.08 2 3
4 13 1585.24 19 14.98 2392 681 2.33 / 289.76 2 6
5 13 1008.92 19 15.01 1647 470 2.80 / 290.23 2 3
6 13 409.04 19 15.12 849 244 3.04 / 290.48 2 3
7 8 0.32 175 15.16 314 833 3.87 / 291.31 2 5
Average= 3.69
(KJ/cycle)

Cycle 77 GMT 25/ 9/2022 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 15.11 486 228 0.23 / 283.85 2 3
2 12 1296.84 2 15.29 2112 65 0.29 / 283.92 2 2
3 7 2002.64 32 14.95 2918 1396 1.69 / 285.31 2 2
4 13 1573.72 19 14.95 2380 676 2.36 / 285.99 2 4
5 13 980.28 19 15.01 1615 461 2.82 / 286.45 2 4
6 13 245.32 19 15.15 623 179 3.00 / 286.63 2 3
7 8 0.40 175 15.15 305 809 3.81 / 287.44 2 3
Average= 3.69
(KJ/cycle)

Cycle 76 GMT 15/ 9/2022 3:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.11 491 230 0.23 / 280.12 2 3
2 12 1300.28 2 15.30 2116 65 0.29 / 280.18 2 2
3 7 2001.84 31 14.98 2919 1356 1.65 / 281.54 2 4
4 13 1577.32 19 14.97 2395 681 2.33 / 282.22 2 3
5 13 999.88 19 15.01 1641 468 2.80 / 282.69 2 4
6 13 264.68 19 15.14 651 187 2.99 / 282.87 2 2
7 8 -0.20 175 15.16 283 751 3.74 / 283.62 2 5
Average= 3.68
(KJ/cycle)

Cycle 75 GMT 5/ 9/2022 5:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 31 15.12 504 236 0.24 / 276.34 2 2
2 12 1309.68 2 15.31 2144 66 0.30 / 276.41 2 2
3 7 2002.56 31 14.98 2917 1355 1.66 / 277.76 2 3
4 13 1566.04 19 14.98 2371 675 2.33 / 278.44 2 4
5 13 970.32 19 15.03 1598 456 2.79 / 278.90 2 3
6 13 236.24 19 15.17 609 176 2.96 / 279.07 2 3
7 8 0.20 175 15.16 307 814 3.78 / 279.89 2 5
Average= 3.68
(KJ/cycle)

Cycle 74 GMT 26/ 8/2022 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.11 485 227 0.23 / 272.58 2 3
2 12 1304.68 2 15.31 2132 65 0.29 / 272.64 2 2
3 7 2002.72 31 14.98 2919 1356 1.65 / 274.00 2 3
4 13 1465.28 19 15.00 2248 641 2.29 / 274.64 2 5
5 13 909.68 19 15.05 1523 436 2.72 / 275.07 2 3
6 13 322.56 19 15.16 727 209 2.93 / 275.28 2 3
7 8 0.24 175 15.17 311 826 3.76 / 276.11 2 4
Average= 3.68
(KJ/cycle)

Cycle 73 GMT 16/ 8/2022 9:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 31 15.12 476 223 0.22 / 268.73 2 2
2 12 1317.56 2 15.30 2170 66 0.29 / 268.80 2 2
3 7 2006.04 32 14.97 2926 1402 1.69 / 270.20 2 2
4 13 1576.32 19 14.97 2395 681 2.37 / 270.88 2 5
5 13 984.56 19 15.03 1618 462 2.83 / 271.34 2 5
6 13 257.60 19 15.15 641 185 3.02 / 271.53 2 3
7 8 0.00 175 15.16 310 822 3.84 / 272.35 2 3
Average= 3.68
(KJ/cycle)

Cycle 72 GMT 6/ 8/2022 11:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.11 488 229 0.23 / 265.00 2 2
2 12 1296.92 2 15.31 2127 65 0.29 / 265.07 2 2
3 7 2003.28 31 14.98 2915 1354 1.65 / 266.42 2 3
4 13 1569.36 19 14.96 2378 676 2.32 / 267.10 2 3
5 13 980.36 19 15.02 1612 460 2.78 / 267.56 2 4
6 13 247.08 19 15.16 629 181 2.96 / 267.74 2 3
7 8 0.04 175 15.17 290 770 3.73 / 268.51 2 4
Average= 3.68
(KJ/cycle)

Cycle 71 GMT 27/ 7/2022 13:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 15.11 489 229 0.23 / 261.11 2 2
2 12 1311.96 2 15.30 2152 66 0.29 / 261.18 2 2
3 7 2005.88 31 14.99 2919 1356 1.65 / 262.54 2 3
4 13 1576.56 19 14.97 2395 681 2.33 / 263.22 2 6
5 13 999.92 19 15.03 1637 467 2.80 / 263.69 2 4
6 13 268.64 19 15.16 657 189 2.99 / 263.87 2 3
7 8 0.16 175 15.17 303 804 3.79 / 264.68 2 4
8 14 0.16 20 15.15 311 94 3.89 / 264.77 2 3
Average= 3.68
(KJ/cycle)

Cycle 70 GMT 17/ 7/2022 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 31 15.13 471 221 0.22 / 257.20 2 3
2 12 1310.40 2 15.30 2149 66 0.29 / 257.27 2 2
3 7 2003.48 31 14.99 2924 1359 1.65 / 258.63 2 4
4 13 1576.16 19 14.98 2390 680 2.33 / 259.31 2 3
5 13 1000.56 19 15.03 1639 468 2.79 / 259.78 2 4
6 13 266.92 19 15.16 652 188 2.98 / 259.96 2 3
7 8 0.08 175 15.16 310 822 3.80 / 260.79 2 3
8 14 0.08 20 15.14 324 98 3.90 / 260.89 2 6
Average= 3.67
(KJ/cycle)

Cycle 69 GMT 7/ 7/2022 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 15.13 477 224 0.22 / 253.43 2 3
2 12 1149.60 2 15.34 1920 59 0.28 / 253.49 2 2
3 7 2003.76 31 14.99 2922 1358 1.64 / 254.84 2 4
4 13 1571.00 19 14.99 2391 681 2.32 / 255.52 2 4
5 13 984.24 19 15.05 1616 462 2.78 / 255.99 2 4
6 13 233.92 19 15.17 612 176 2.96 / 256.16 2 2
7 8 0.16 175 15.19 275 731 3.69 / 256.89 2 2
8 14 0.16 20 15.17 293 89 3.78 / 256.98 2 3
Average= 3.67
(KJ/cycle)

Cycle 68 GMT 27/ 6/2022 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 31 15.13 489 229 0.23 / 249.69 2 3
2 12 1169.04 2 15.35 1956 60 0.29 / 249.75 2 2
3 7 2002.16 31 15.00 2920 1358 1.65 / 251.11 2 3
4 13 1567.12 19 15.00 2380 678 2.33 / 251.79 2 4
5 13 982.44 19 15.06 1620 464 2.79 / 252.25 2 4
6 13 242.52 19 15.19 617 178 2.97 / 252.43 2 3
7 8 0.04 175 15.19 290 771 3.74 / 253.20 2 3
Average= 3.67
(KJ/cycle)

Cycle 67 GMT 17/ 6/2022 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 31 15.14 492 231 0.23 / 245.88 2 3
2 12 1154.84 2 15.34 1923 59 0.29 / 245.94 2 2
3 7 2007.36 31 14.99 2934 1363 1.65 / 247.30 2 4
4 13 1572.60 19 14.98 2385 679 2.33 / 247.98 2 4
5 13 978.00 19 15.05 1610 460 2.79 / 248.44 2 4
6 13 236.56 19 15.18 605 174 2.97 / 248.61 2 3
7 8 0.04 175 15.17 321 852 3.82 / 249.47 2 4
Average= 3.67
(KJ/cycle)

Cycle 66 GMT 7/ 6/2022 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 31 15.15 493 232 0.23 / 242.07 2 3
2 12 1159.80 2 15.36 1944 60 0.29 / 242.13 2 2
3 7 2006.56 31 15.01 2931 1364 1.66 / 243.50 2 3
4 13 1579.92 19 14.99 2396 682 2.34 / 244.18 2 4
5 13 987.36 19 15.06 1625 465 2.80 / 244.64 2 3
6 13 256.12 19 15.20 637 184 2.99 / 244.83 2 3
7 8 0.24 175 15.20 308 819 3.81 / 245.65 2 3
Average= 3.67
(KJ/cycle)

Cycle 65 GMT 29/ 5/2022 1:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.15 498 234 0.23 / 238.43 2 3
2 12 1166.08 2 15.35 1934 59 0.29 / 238.49 2 2
3 7 2004.80 31 15.01 2927 1362 1.66 / 239.85 2 5
4 13 1457.04 19 15.00 2240 638 2.29 / 240.49 2 3
5 13 891.76 19 15.08 1502 430 2.72 / 240.92 2 4
6 13 168.40 19 15.21 517 149 2.87 / 241.07 2 3
7 8 -0.32 175 15.20 291 774 3.65 / 241.84 2 3
Average= 3.66
(KJ/cycle)

Cycle 64 GMT 19/ 5/2022 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 31 15.14 491 230 0.23 / 234.72 2 3
2 12 1302.84 2 15.32 2154 66 0.30 / 234.79 2 2
3 7 2002.72 31 15.00 2922 1359 1.66 / 236.15 2 4
4 13 1558.40 19 15.01 2369 676 2.33 / 236.82 2 3
5 13 963.36 19 15.06 1594 456 2.79 / 237.28 2 4
6 13 227.88 19 15.20 601 174 2.96 / 237.45 2 3
7 8 0.12 175 15.21 279 743 3.70 / 238.19 2 4
Average= 3.66
(KJ/cycle)

Cycle 63 GMT 9/ 5/2022 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 31 15.16 499 235 0.23 / 230.97 2 3
2 12 1316.68 2 15.32 2154 66 0.30 / 231.03 2 2
3 7 2004.80 31 14.99 2922 1358 1.66 / 232.39 2 4
4 13 1563.48 19 15.00 2369 675 2.33 / 233.07 2 4
5 13 965.32 19 15.06 1597 457 2.79 / 233.52 2 3
6 13 235.08 19 15.20 608 176 2.97 / 233.70 2 2
7 8 0.32 175 15.20 297 790 3.76 / 234.49 2 3
Average= 3.66
(KJ/cycle)

Cycle 62 GMT 29/ 4/2022 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 31 15.16 491 231 0.23 / 227.15 2 3
2 12 1307.08 2 15.32 2144 66 0.30 / 227.21 2 2
3 7 2001.44 31 15.01 2912 1355 1.65 / 228.57 2 4
4 13 1569.68 19 15.00 2382 679 2.33 / 229.25 2 2
5 13 971.12 19 15.08 1603 459 2.79 / 229.71 2 4
6 13 234.12 19 15.23 607 176 2.97 / 229.88 2 3
7 8 -0.04 175 15.22 283 754 3.72 / 230.64 2 8
8 14 -0.04 20 15.19 323 98 3.82 / 230.73 2 3
Average= 3.66
(KJ/cycle)

Cycle 61 GMT 19/ 4/2022 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 31 15.18 477 224 0.22 / 223.37 2 3
2 12 1298.20 2 15.32 2129 65 0.29 / 223.43 2 2
3 7 2006.12 31 15.01 2927 1362 1.65 / 224.79 2 3
4 13 1445.80 19 15.03 2224 635 2.29 / 225.43 2 4
5 13 891.92 19 15.10 1502 431 2.72 / 225.86 2 4
6 13 295.16 19 15.20 691 200 2.92 / 226.06 2 2
7 8 0.20 175 15.21 286 761 3.68 / 226.82 2 5
8 14 0.20 20 15.19 318 97 3.78 / 226.92 2 5
Average= 3.66
(KJ/cycle)

Cycle 60 GMT 9/ 4/2022 11:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 15.17 507 238 0.24 / 219.67 2 3
2 12 1312.32 2 15.33 2143 66 0.30 / 219.73 2 2
3 7 2002.76 31 15.02 2925 1362 1.67 / 221.10 2 3
4 13 1455.68 19 15.02 2236 638 2.30 / 221.73 2 5
5 13 895.60 19 15.09 1509 433 2.74 / 222.17 2 3
6 13 176.32 19 15.25 534 155 2.89 / 222.32 2 3
7 8 -0.16 175 15.24 276 736 3.63 / 223.06 2 4
8 14 -0.16 20 15.22 276 84 3.71 / 223.14 2 5
Average= 3.66
(KJ/cycle)

Cycle 59 GMT 30/ 3/2022 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 31 15.18 486 229 0.23 / 215.92 2 3
2 12 1316.16 2 15.33 2167 66 0.30 / 215.98 2 2
3 7 2003.96 31 15.01 2919 1358 1.65 / 217.34 2 3
4 13 1563.04 19 15.00 2366 674 2.33 / 218.01 2 4
5 13 975.52 19 15.09 1610 462 2.79 / 218.48 2 4
6 13 236.36 19 15.24 606 175 2.96 / 218.65 2 3
7 8 0.24 175 15.24 292 779 3.74 / 219.43 2 7
Average= 3.66
(KJ/cycle)

Cycle 58 GMT 20/ 3/2022 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 15.18 504 237 0.24 / 212.25 2 3
2 12 1306.60 2 15.34 2132 65 0.30 / 212.32 2 2
3 7 2004.00 31 15.02 2917 1358 1.66 / 213.68 2 4
4 13 1452.68 19 15.03 2230 637 2.30 / 214.31 2 3
5 13 892.44 19 15.11 1496 429 2.73 / 214.74 2 4
6 13 297.32 19 15.21 694 201 2.93 / 214.94 2 3
7 8 0.04 175 15.24 279 744 3.67 / 215.69 2 5
Average= 3.66
(KJ/cycle)

Cycle 57 GMT 10/ 3/2022 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 15.19 498 235 0.23 / 208.48 2 3
2 12 1306.08 2 15.35 2136 66 0.30 / 208.55 2 2
3 7 2002.92 31 15.02 2913 1356 1.66 / 209.91 2 6
4 13 1562.76 19 15.02 2367 675 2.33 / 210.58 2 3
5 13 970.00 19 15.09 1601 459 2.79 / 211.04 2 3
6 13 232.40 19 15.23 609 176 2.97 / 211.22 2 3
7 8 0.04 175 15.24 299 797 3.76 / 212.01 2 9
Average= 3.66
(KJ/cycle)

Cycle 56 GMT 28/ 2/2022 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 15.19 496 234 0.23 / 204.70 2 3
2 12 1169.96 2 15.39 1956 60 0.29 / 204.76 2 2
3 7 2003.16 31 15.03 2923 1362 1.66 / 206.12 2 4
4 13 1440.36 19 15.05 2219 635 2.29 / 206.76 2 3
5 13 886.88 19 15.12 1488 427 2.72 / 207.19 2 3
6 13 293.76 19 15.23 689 199 2.92 / 207.38 2 3
7 8 0.16 175 15.26 287 766 3.68 / 208.15 2 9
8 14 0.16 20 15.23 326 99 3.78 / 208.25 2 6
Average= 3.65
(KJ/cycle)

Cycle 55 GMT 18/ 2/2022 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 31 15.19 491 231 0.23 / 200.95 2 3
2 12 1322.92 2 15.33 2147 66 0.30 / 201.02 2 2
3 7 2006.80 31 15.02 2925 1362 1.66 / 202.38 2 4
4 13 1573.12 19 15.03 2382 680 2.34 / 203.06 2 3
5 13 974.36 19 15.10 1606 461 2.80 / 203.52 2 4
6 13 230.36 19 15.25 602 174 2.97 / 203.70 2 3
7 8 0.36 175 15.25 289 771 3.75 / 204.47 2 4
Average= 3.65
(KJ/cycle)

Cycle 54 GMT 8/ 2/2022 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 31 15.21 495 233 0.23 / 197.31 2 3
2 12 1316.04 2 15.33 2152 66 0.30 / 197.38 2 2
3 7 2004.40 31 15.03 2914 1358 1.66 / 198.74 2 3
4 13 1456.32 19 15.04 2224 636 2.29 / 199.37 2 3
5 13 906.56 19 15.12 1508 433 2.73 / 199.81 2 5
6 13 186.24 19 15.26 538 156 2.88 / 199.96 2 3
7 8 0.00 175 15.25 285 761 3.64 / 200.72 2 6
Average= 3.65
(KJ/cycle)

Cycle 53 GMT 30/ 1/2022 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 31 15.20 499 235 0.24 / 193.59 2 3
2 12 1166.68 2 15.39 1923 59 0.29 / 193.65 2 2
3 7 2005.00 31 15.03 2915 1358 1.65 / 195.01 2 3
4 13 1565.48 19 15.03 2373 678 2.33 / 195.69 2 3
5 13 976.36 19 15.11 1606 461 2.79 / 196.15 2 3
6 13 237.36 19 15.26 610 177 2.97 / 196.32 2 3
7 8 0.08 175 15.27 283 756 3.72 / 197.08 2 4
Average= 3.65
(KJ/cycle)

Cycle 52 GMT 20/ 1/2022 2:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 15.20 501 236 0.24 / 189.93 2 3
2 12 1310.40 2 15.36 2146 66 0.30 / 190.00 2 2
3 7 2006.04 31 15.04 2915 1359 1.66 / 191.36 2 3
4 13 1445.52 19 15.05 2221 635 2.30 / 191.99 2 3
5 13 896.28 19 15.13 1507 433 2.73 / 192.43 2 4
6 13 174.40 19 15.27 527 153 2.88 / 192.58 2 3
7 8 0.16 175 15.26 290 774 3.66 / 193.35 2 3
Average= 3.65
(KJ/cycle)

Cycle 51 GMT 10/ 1/2022 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.20 500 236 0.24 / 186.18 2 3
2 12 1314.92 2 15.34 2176 67 0.30 / 186.25 2 2
3 7 2006.76 31 15.02 2916 1358 1.66 / 187.61 2 3
4 13 1457.68 19 15.04 2235 639 2.30 / 188.25 2 3
5 13 905.72 19 15.11 1509 433 2.73 / 188.68 2 4
6 13 183.84 19 15.26 537 156 2.89 / 188.84 2 3
7 8 0.24 175 15.26 323 863 3.75 / 189.70 2 6
Average= 3.65
(KJ/cycle)

Cycle 50 GMT 31/12/2021 5:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 15.21 506 239 0.24 / 182.44 2 3
2 12 1325.64 2 15.36 2163 66 0.31 / 182.51 2 2
3 7 2002.88 31 15.04 2912 1358 1.66 / 183.86 2 3
4 13 1574.32 19 15.04 2382 681 2.34 / 184.54 2 4
5 13 976.92 19 15.11 1604 460 2.80 / 185.00 2 6
6 13 237.68 19 15.26 608 176 2.98 / 185.18 2 3
7 8 -0.04 175 15.27 287 767 3.75 / 185.95 2 4
Average= 3.65
(KJ/cycle)

Cycle 49 GMT 21/12/2021 8: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 31 15.23 513 242 0.24 / 178.62 2 3
2 12 1310.16 2 15.36 2138 66 0.31 / 178.69 2 2
3 7 2003.96 31 15.05 2920 1362 1.67 / 180.05 2 2
4 13 1456.92 19 15.07 2235 640 2.31 / 180.69 2 5
5 13 905.48 19 15.14 1510 434 2.74 / 181.12 2 4
6 13 182.64 19 15.28 537 156 2.90 / 181.28 2 2
7 8 0.04 175 15.28 307 821 3.72 / 182.10 2 4
8 14 0.04 20 15.25 334 102 3.82 / 182.20 2 3
Average= 3.64
(KJ/cycle)

Cycle 48 GMT 11/12/2021 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.24 490 231 0.23 / 174.91 2 3
2 12 1313.56 2 15.37 2151 66 0.30 / 174.97 2 2
3 7 2005.12 31 15.05 2911 1358 1.66 / 176.33 2 4
4 13 1448.80 19 15.07 2227 638 2.29 / 176.97 2 4
5 13 1010.64 19 15.12 1648 473 2.77 / 177.44 2 4
6 13 260.32 19 15.27 642 186 2.95 / 177.63 2 3
7 8 0.16 175 15.29 280 749 3.70 / 178.38 2 3
Average= 3.64
(KJ/cycle)

Cycle 47 GMT 1/12/2021 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.22 515 243 0.24 / 171.17 2 3
2 12 1322.08 2 15.35 2166 66 0.31 / 171.24 2 2
3 7 2009.12 31 15.05 2927 1366 1.68 / 172.60 2 3
4 13 1573.16 19 15.05 2379 680 2.36 / 173.28 2 3
5 13 983.04 19 15.12 1618 465 2.82 / 173.75 2 4
6 13 225.00 19 15.28 595 173 2.99 / 173.92 2 3
7 8 -0.08 175 15.29 282 755 3.75 / 174.68 2 3
Average= 3.64
(KJ/cycle)

Cycle 46 GMT 21/11/2021 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 31 15.24 505 239 0.24 / 167.34 2 3
2 12 1316.88 2 15.36 2165 67 0.31 / 167.41 2 2
3 7 2002.84 31 15.05 2916 1360 1.67 / 168.77 2 3
4 13 1568.44 19 15.05 2372 678 2.34 / 169.45 2 3
5 13 984.64 19 15.13 1615 464 2.81 / 169.91 2 4
6 13 246.96 19 15.27 620 180 2.99 / 170.09 2 3
7 8 0.24 175 15.28 312 834 3.82 / 170.93 2 4
Average= 3.64
(KJ/cycle)

Cycle 45 GMT 11/11/2021 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 15.25 437 207 0.21 / 163.62 2 3
2 12 1308.52 2 15.37 2137 66 0.27 / 163.69 2 2
3 7 2002.76 31 15.06 2912 1359 1.63 / 165.05 2 6
4 13 1566.32 19 15.06 2372 679 2.31 / 165.73 2 4
5 13 967.24 19 15.14 1593 458 2.77 / 166.19 2 4
6 13 221.76 19 15.28 585 170 2.94 / 166.36 2 3
7 8 0.12 175 15.30 280 750 3.69 / 167.11 2 6
Average= 3.63
(KJ/cycle)

Cycle 44 GMT 1/11/2021 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 15.25 504 238 0.24 / 159.93 2 3
2 12 1165.88 2 15.41 1954 60 0.30 / 159.99 2 2
3 7 2006.76 31 15.06 2913 1360 1.66 / 161.35 2 5
4 13 1576.36 19 15.06 2380 681 2.34 / 162.04 2 2
5 13 985.16 19 15.14 1607 462 2.80 / 162.50 2 4
6 13 242.04 19 15.29 611 178 2.98 / 162.68 2 3
7 8 0.00 175 15.30 277 742 3.72 / 163.42 2 3
Average= 3.63
(KJ/cycle)

Cycle 43 GMT 22/10/2021 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 15.24 506 239 0.24 / 156.20 2 3
2 12 1312.36 2 15.38 2107 65 0.30 / 156.27 2 2
3 7 2003.56 31 15.06 2914 1360 1.66 / 157.63 2 4
4 13 1575.08 19 15.07 2380 681 2.35 / 158.31 2 3
5 13 974.12 19 15.15 1604 462 2.81 / 158.77 2 4
6 13 233.80 19 15.30 600 174 2.98 / 158.95 2 3
7 8 0.28 175 15.31 280 750 3.73 / 159.70 2 4
Average= 3.63
(KJ/cycle)

Cycle 42 GMT 12/10/2021 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 31 15.24 515 243 0.24 / 152.40 2 3
2 12 1308.76 2 15.39 2144 66 0.31 / 152.47 2 2
3 7 2004.56 31 15.06 2923 1365 1.67 / 153.83 2 3
4 13 1568.68 19 15.05 2378 680 2.35 / 154.51 2 4
5 13 967.24 19 15.15 1587 457 2.81 / 154.97 2 5
6 13 221.72 19 15.29 582 169 2.98 / 155.14 2 3
7 8 0.04 175 15.30 308 825 3.80 / 155.96 2 5
Average= 3.63
(KJ/cycle)

Cycle 41 GMT 2/10/2021 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 31 15.26 488 231 0.23 / 148.62 2 3
2 12 1168.76 2 15.42 1937 60 0.29 / 148.68 2 2
3 7 2003.16 31 15.06 2918 1362 1.65 / 150.04 2 2
4 13 1564.32 19 15.07 2367 678 2.33 / 150.72 2 8
5 13 967.96 19 15.15 1586 457 2.79 / 151.17 2 4
6 13 216.04 19 15.31 581 169 2.96 / 151.34 2 3
7 8 0.08 175 15.31 305 817 3.77 / 152.16 2 3
Average= 3.62
(KJ/cycle)

Cycle 40 GMT 23/ 9/2021 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 31 15.26 442 209 0.21 / 144.87 2 3
2 12 1148.88 2 15.42 1915 59 0.27 / 144.93 2 2
3 7 2003.44 31 15.07 2914 1361 1.63 / 146.29 2 7
4 13 1569.04 19 15.07 2375 680 2.31 / 146.97 2 3
5 13 982.20 19 15.15 1604 462 2.77 / 147.43 2 5
6 13 125.04 19 15.32 456 133 2.90 / 147.56 2 3
7 13 23.28 19 15.34 313 91 3.00 / 147.66 2 2
8 8 -0.08 175 15.31 273 731 3.73 / 148.39 2 5
Average= 3.62
(KJ/cycle)

Cycle 39 GMT 13/ 9/2021 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 15.28 437 207 0.21 / 141.28 2 3
2 12 1320.84 2 15.40 2133 66 0.27 / 141.35 2 2
3 7 2003.64 31 15.07 2913 1361 1.63 / 142.71 2 3
4 13 1448.88 19 15.08 2219 636 2.27 / 143.35 2 8
5 13 898.36 19 15.17 1495 431 2.70 / 143.78 2 3
6 13 175.20 19 15.31 518 151 2.85 / 143.93 2 3
7 8 0.24 175 15.31 273 731 3.58 / 144.66 2 6
Average= 3.62
(KJ/cycle)

Cycle 38 GMT 3/ 9/2021 5:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 15.27 427 202 0.20 / 137.63 2 3
2 12 1317.12 2 15.39 2127 65 0.27 / 137.70 2 2
3 7 2007.28 31 15.08 2909 1360 1.63 / 139.06 2 3
4 13 1461.36 19 15.09 2237 641 2.27 / 139.70 2 3
5 13 905.92 19 15.17 1500 432 2.70 / 140.13 2 4
6 13 172.28 19 15.31 515 150 2.85 / 140.28 2 3
7 8 -0.08 175 15.32 266 713 3.56 / 140.99 2 4
8 14 -0.08 20 15.31 271 83 3.65 / 141.08 2 7
Average= 3.62
(KJ/cycle)

Cycle 37 GMT 24/ 8/2021 7: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 31 15.29 435 206 0.21 / 133.97 2 3
2 12 1159.04 2 15.43 1907 59 0.27 / 134.02 2 2
3 7 2003.36 31 15.07 2916 1362 1.63 / 135.39 2 2
4 13 1445.28 19 15.09 2213 634 2.26 / 136.02 2 3
5 13 1005.84 19 15.15 1637 471 2.73 / 136.49 2 6
6 13 127.76 19 15.33 453 132 2.86 / 136.62 2 2
7 8 0.48 175 15.32 270 724 3.59 / 137.35 2 3
8 14 0.48 20 15.30 267 82 3.67 / 137.43 2 3
Average= 3.62
(KJ/cycle)

Cycle 36 GMT 14/ 8/2021 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 15.28 427 202 0.20 / 130.30 2 3
2 12 1317.16 2 15.39 2141 66 0.27 / 130.36 2 2
3 7 2003.60 31 15.07 2912 1360 1.63 / 131.72 2 3
4 13 1456.72 19 15.10 2226 639 2.27 / 132.36 2 3
5 13 901.28 19 15.17 1496 431 2.70 / 132.79 2 3
6 13 161.96 19 15.33 504 147 2.85 / 132.94 2 3
7 8 0.20 175 15.32 275 737 3.58 / 133.68 2 4
8 14 0.20 20 15.31 276 85 3.67 / 133.76 3 6
Average= 3.62
(KJ/cycle)

Cycle 35 GMT 4/ 8/2021 10:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 31 15.28 441 209 0.21 / 126.60 2 3
2 12 1300.84 2 15.39 2099 65 0.27 / 126.66 2 2
3 7 2003.44 31 15.08 2921 1366 1.64 / 128.03 2 3
4 13 1456.08 19 15.10 2226 639 2.28 / 128.67 2 4
5 13 1018.24 19 15.15 1654 476 2.75 / 129.14 2 6
6 13 132.96 19 15.33 465 135 2.89 / 129.28 2 3
7 8 0.40 175 15.32 272 729 3.62 / 130.01 2 4
8 14 0.40 20 15.31 273 84 3.70 / 130.09 2 6
Average= 3.61
(KJ/cycle)

Cycle 34 GMT 25/ 7/2021 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 15.27 440 208 0.21 / 122.97 2 3
2 12 1318.60 2 15.40 2139 66 0.27 / 123.04 2 2
3 7 2002.80 31 15.07 2912 1360 1.63 / 124.40 2 4
4 13 1568.56 19 15.08 2378 681 2.32 / 125.08 2 5
5 13 971.56 19 15.17 1592 459 2.77 / 125.54 2 3
6 13 122.12 19 15.33 446 130 2.90 / 125.67 2 3
7 8 0.12 175 15.32 270 724 3.63 / 126.39 2 4
Average= 3.61
(KJ/cycle)

Cycle 33 GMT 15/ 7/2021 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 31 15.27 441 209 0.21 / 119.22 2 3
2 12 1316.88 2 15.40 2138 66 0.27 / 119.29 2 2
3 7 2006.00 31 15.08 2921 1366 1.64 / 120.66 2 4
4 13 1570.68 19 15.08 2383 683 2.32 / 121.34 2 3
5 13 975.52 19 15.17 1600 461 2.78 / 121.80 2 3
6 13 364.48 19 15.28 785 228 3.01 / 122.03 2 3
7 8 -0.28 175 15.32 274 735 3.75 / 122.76 2 4
Average= 3.61
(KJ/cycle)

Cycle 32 GMT 5/ 7/2021 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 31 15.29 449 213 0.21 / 115.56 2 3
2 12 1311.96 2 15.40 2140 66 0.28 / 115.62 2 2
3 7 2001.64 31 15.07 2909 1359 1.64 / 116.98 2 7
4 13 1555.72 19 15.10 2354 675 2.31 / 117.66 2 4
5 13 967.28 19 15.18 1588 458 2.77 / 118.12 2 3
6 13 216.24 19 15.32 578 168 2.94 / 118.28 2 3
7 8 0.20 175 15.33 273 732 3.67 / 119.02 2 4
Average= 3.61
(KJ/cycle)

Cycle 31 GMT 25/ 6/2021 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 31 15.28 442 209 0.21 / 111.79 2 3
2 12 1312.36 2 15.40 2129 66 0.27 / 111.85 2 2
3 7 2002.40 31 15.08 2907 1359 1.63 / 113.21 2 4
4 13 1559.36 19 15.09 2364 678 2.31 / 113.89 2 3
5 13 963.24 19 15.17 1586 457 2.77 / 114.35 2 4
6 13 211.44 19 15.33 575 167 2.94 / 114.52 2 3
7 8 0.00 175 15.33 277 743 3.68 / 115.26 2 4
8 14 0.00 20 15.32 278 85 3.76 / 115.34 2 9
Average= 3.60
(KJ/cycle)

Cycle 30 GMT 15/ 6/2021 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.29 444 210 0.21 / 108.13 2 3
2 12 1315.28 2 15.40 2111 65 0.28 / 108.20 2 2
3 7 2007.64 31 15.08 2921 1366 1.64 / 109.56 2 3
4 13 1582.80 19 15.08 2387 684 2.32 / 110.25 2 6
5 13 983.56 19 15.17 1611 464 2.79 / 110.71 2 4
6 13 123.84 19 15.33 454 132 2.92 / 110.84 2 2
7 8 0.12 175 15.32 274 735 3.66 / 111.58 2 3
Average= 3.60
(KJ/cycle)

Cycle 29 GMT 5/ 6/2021 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 31 15.28 434 206 0.21 / 104.46 2 2
2 12 1167.12 2 15.44 1937 60 0.27 / 104.52 2 2
3 7 2003.04 31 15.08 2913 1362 1.63 / 105.88 2 3
4 13 1579.88 19 15.09 2384 684 2.31 / 106.56 2 7
5 13 970.20 19 15.18 1594 460 2.77 / 107.02 2 3
6 13 212.92 19 15.31 576 168 2.94 / 107.19 2 2
7 8 0.08 175 15.32 274 735 3.67 / 107.92 2 4
Average= 3.60
(KJ/cycle)

Cycle 28 GMT 26/ 5/2021 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 15.29 441 209 0.21 / 100.70 2 3
2 12 1318.72 2 15.41 2162 67 0.28 / 100.77 2 2
3 7 2003.08 32 15.09 2909 1405 1.68 / 102.17 2 8
4 13 1452.36 19 15.11 2221 638 2.32 / 102.81 2 3
5 13 1017.20 19 15.17 1656 477 2.80 / 103.29 2 4
6 13 140.76 19 15.35 477 139 2.93 / 103.43 2 2
7 8 0.04 175 15.34 276 741 3.68 / 104.17 2 5
8 14 0.04 20 15.32 274 84 3.76 / 104.25 3 5
Average= 3.59
(KJ/cycle)

Cycle 27 GMT 17/ 5/2021 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.29 429 203 0.20 / 96.96 2 3
2 12 1167.92 2 15.44 1917 59 0.26 / 97.02 2 2
3 7 2004.16 32 15.09 2921 1410 1.67 / 98.43 2 5
4 13 1571.32 19 15.11 2387 685 2.36 / 99.12 2 6
5 13 977.84 19 15.19 1605 463 2.82 / 99.58 2 4
6 13 224.44 19 15.34 586 171 2.99 / 99.75 2 2
7 8 0.28 175 15.34 276 741 3.73 / 100.49 2 5
Average= 3.59
(KJ/cycle)

Cycle 26 GMT 7/ 5/2021 3:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 30 15.29 434 199 0.20 / 93.31 2 2
2 12 1312.04 1 15.43 2136 33 0.23 / 93.35 2 2
3 7 2003.56 31 15.09 2907 1360 1.59 / 94.71 2 4
4 13 1568.28 19 15.10 2374 681 2.27 / 95.39 2 3
5 13 978.84 19 15.18 1613 465 2.74 / 95.85 2 3
6 13 237.16 19 15.32 604 176 2.91 / 96.03 2 3
7 8 0.00 175 15.33 272 730 3.64 / 96.76 2 4
Average= 3.58
(KJ/cycle)

Cycle 25 GMT 27/ 4/2021 5:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 30 15.30 419 192 0.19 / 89.64 2 3
2 12 1321.12 1 15.44 2154 33 0.23 / 89.67 2 2
3 7 2002.64 31 15.10 2913 1364 1.59 / 91.04 2 3
4 13 1580.84 19 15.10 2390 686 2.27 / 91.72 2 3
5 13 1002.00 19 15.18 1639 473 2.75 / 92.20 2 4
6 13 268.24 19 15.32 648 189 2.94 / 92.38 2 3
7 8 0.08 175 15.34 272 730 3.67 / 93.11 2 11
Average= 3.58
(KJ/cycle)

Cycle 24 GMT 17/ 4/2021 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 15.30 437 201 0.20 / 85.91 2 2
2 12 1329.52 1 15.41 2163 33 0.23 / 85.94 2 2
3 7 2003.08 31 15.09 2912 1362 1.60 / 87.31 2 4
4 13 1572.76 19 15.11 2379 683 2.28 / 87.99 2 4
5 13 986.12 19 15.19 1617 467 2.75 / 88.46 2 3
6 13 237.48 19 15.32 605 176 2.92 / 88.63 2 3
7 8 0.20 175 15.34 273 733 3.65 / 89.37 2 4
8 14 0.20 20 15.32 270 83 3.74 / 89.45 2 4
Average= 3.58
(KJ/cycle)

Cycle 23 GMT 7/ 4/2021 9:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 15.28 433 198 0.20 / 82.26 2 2
2 12 1156.40 1 15.46 1928 30 0.23 / 82.29 2 2
3 7 2003.12 31 15.09 2917 1365 1.59 / 83.65 2 2
4 13 1572.84 19 15.11 2385 685 2.28 / 84.34 2 6
5 13 980.44 19 15.19 1608 464 2.74 / 84.80 2 6
6 13 233.52 19 15.35 601 175 2.92 / 84.98 2 3
7 8 0.00 175 15.35 273 733 3.65 / 85.71 2 3
Average= 3.57
(KJ/cycle)

Cycle 22 GMT 28/ 3/2021 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 15.29 436 200 0.20 / 78.62 2 2
2 12 1166.00 1 15.46 1917 30 0.23 / 78.65 2 2
3 7 2003.80 31 15.09 2906 1359 1.59 / 80.01 2 4
4 13 1574.00 19 15.10 2385 684 2.27 / 80.69 2 6
5 13 980.88 19 15.18 1608 464 2.74 / 81.16 2 3
6 13 238.48 19 15.34 608 177 2.91 / 81.34 2 2
7 8 0.04 175 15.34 270 725 3.64 / 82.06 2 3
Average= 3.57
(KJ/cycle)

Cycle 21 GMT 18/ 3/2021 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 30 15.30 436 200 0.20 / 75.04 2 2
2 12 1325.88 1 15.45 2162 33 0.23 / 75.08 2 2
3 7 2002.76 31 15.09 2917 1365 1.60 / 76.44 2 3
4 13 1570.08 19 15.11 2374 682 2.28 / 77.12 2 3
5 13 869.48 19 15.21 1464 423 2.70 / 77.55 2 3
6 13 146.96 19 15.36 484 141 2.84 / 77.69 2 3
7 8 0.28 175 15.35 273 733 3.58 / 78.42 2 4
Average= 3.56
(KJ/cycle)

Cycle 20 GMT 8/ 3/2021 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 30 15.31 434 199 0.20 / 71.47 2 3
2 12 1299.84 1 15.44 2124 33 0.23 / 71.50 2 2
3 7 2006.44 31 15.10 2918 1366 1.60 / 72.87 2 3
4 13 1456.16 19 15.13 2237 643 2.24 / 73.51 2 3
5 13 903.36 19 15.22 1507 436 2.68 / 73.95 2 4
6 13 179.36 19 15.37 533 156 2.83 / 74.10 2 3
7 8 -0.12 175 15.36 275 739 3.57 / 74.84 2 4
Average= 3.56
(KJ/cycle)

Cycle 19 GMT 26/ 2/2021 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 30 15.30 434 199 0.20 / 67.74 2 2
2 12 1325.52 1 15.44 2155 33 0.23 / 67.77 2 2
3 7 2001.64 31 15.11 2910 1363 1.60 / 69.13 2 2
4 13 1564.40 19 15.12 2380 684 2.28 / 69.82 2 4
5 13 972.56 19 15.21 1594 461 2.74 / 70.28 2 6
6 13 222.96 19 15.34 584 170 2.91 / 70.45 2 3
7 13 17.88 19 15.38 306 89 3.00 / 70.54 2 2
8 8 0.04 175 15.35 273 733 3.73 / 71.27 2 5
Average= 3.56
(KJ/cycle)

Cycle 18 GMT 16/ 2/2021 20:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 30 15.31 430 197 0.20 / 64.13 2 2
2 12 1305.48 1 15.45 2127 33 0.23 / 64.16 2 2
3 7 2004.04 31 15.10 2921 1367 1.60 / 65.53 2 5
4 13 1568.00 19 15.11 2379 683 2.28 / 66.21 2 3
5 13 973.72 19 15.19 1603 463 2.74 / 66.67 2 3
6 13 122.48 19 15.36 453 132 2.88 / 66.81 2 3
7 8 0.12 175 15.34 273 733 3.61 / 67.54 2 4
Average= 3.55
(KJ/cycle)

Cycle 17 GMT 6/ 2/2021 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 30 15.32 432 199 0.20 / 60.48 2 3
2 12 1308.96 1 15.46 2140 33 0.23 / 60.51 2 2
3 7 2004.40 31 15.12 2919 1368 1.60 / 61.88 2 5
4 13 1572.48 19 15.13 2384 685 2.29 / 62.56 2 3
5 13 974.64 19 15.22 1600 463 2.75 / 63.03 2 4
6 13 230.72 19 15.35 598 174 2.92 / 63.20 2 3
7 8 -0.12 175 15.36 272 731 3.65 / 63.93 2 4
Average= 3.55
(KJ/cycle)

Cycle 16 GMT 28/ 1/2021 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 15.31 435 200 0.20 / 56.88 2 2
2 12 1306.32 1 15.45 2119 33 0.23 / 56.91 2 2
3 7 2005.00 31 15.11 2914 1365 1.60 / 58.28 2 5
4 13 1570.96 18 15.13 2378 648 2.25 / 58.92 2 6
5 13 986.80 18 15.20 1613 441 2.69 / 59.36 2 3
6 13 265.44 18 15.34 647 179 2.87 / 59.54 2 3
7 8 0.24 175 15.37 273 734 3.60 / 60.28 2 4
Average= 3.55
(KJ/cycle)

Cycle 15 GMT 18/ 1/2021 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 15.34 441 203 0.20 / 53.10 2 3
2 12 1163.92 1 15.49 1934 30 0.23 / 53.13 2 2
3 7 2004.12 31 15.13 2929 1374 1.61 / 54.51 2 4
4 13 1578.40 18 15.15 2395 653 2.26 / 55.16 2 4
5 13 1004.08 18 15.21 1644 450 2.71 / 55.61 2 3
6 13 411.84 18 15.32 851 235 2.94 / 55.84 2 3
7 13 20.76 18 15.40 321 89 3.03 / 55.93 2 2
8 8 0.16 175 15.36 277 745 3.78 / 56.68 2 5
Average= 3.54
(KJ/cycle)

Cycle 14 GMT 8/ 1/2021 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 30 15.33 431 198 0.20 / 49.48 2 2
2 7 2002.68 32 15.13 2914 1411 1.61 / 50.89 2 6
3 13 1561.72 18 15.17 2369 647 2.26 / 51.54 2 5
4 13 982.64 18 15.24 1616 443 2.70 / 51.98 2 3
5 13 253.68 18 15.36 632 175 2.87 / 52.16 2 3
6 8 0.24 175 15.38 276 743 3.62 / 52.90 2 4
Average= 3.53
(KJ/cycle)

Cycle 13 GMT 29/12/2020 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 15.34 435 200 0.20 / 45.86 2 3
2 7 2006.04 32 15.12 2911 1408 1.61 / 47.27 2 4
3 13 1566.72 18 15.15 2374 647 2.26 / 47.92 2 6
4 13 981.00 18 15.23 1615 443 2.70 / 48.36 2 3
5 13 254.08 18 15.36 635 176 2.87 / 48.54 2 3
6 8 0.12 175 15.38 277 746 3.62 / 49.28 2 3
Average= 3.52
(KJ/cycle)

Cycle 12 GMT 19/12/2020 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 15.34 441 203 0.20 / 42.24 2 3
2 7 2004.84 33 15.13 2912 1454 1.66 / 43.69 2 3
3 13 1455.88 18 15.18 2233 610 2.27 / 44.30 2 4
4 13 907.44 18 15.25 1512 415 2.68 / 44.72 2 3
5 13 322.12 18 15.34 721 199 2.88 / 44.92 2 3
6 8 0.04 175 15.37 277 745 3.63 / 45.66 2 6
Average= 3.51
(KJ/cycle)

Cycle 11 GMT 9/12/2020 10:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 30 15.34 437 201 0.20 / 38.60 2 2
2 7 2002.56 33 15.14 2914 1456 1.66 / 40.06 2 5
3 13 1443.16 18 15.19 2216 606 2.26 / 40.66 2 3
4 13 1018.60 18 15.24 1655 454 2.72 / 41.12 2 4
5 13 274.40 18 15.37 657 182 2.90 / 41.30 2 3
6 8 0.12 175 15.38 274 737 3.64 / 42.04 2 4
Average= 3.50
(KJ/cycle)

Cycle 10 GMT 29/11/2020 12:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 30 15.33 428 197 0.20 / 34.80 2 3
2 7 2007.20 33 15.13 2924 1460 1.66 / 36.26 2 3
3 13 1568.44 18 15.17 2385 651 2.31 / 36.91 2 3
4 13 972.20 18 15.24 1599 439 2.75 / 37.35 2 3
5 13 372.72 18 15.36 798 221 2.97 / 37.57 2 3
6 8 -0.12 175 15.39 276 743 3.71 / 38.32 2 4
7 14 -0.12 20 15.37 276 85 3.80 / 38.40 2 5
Average= 3.49
(KJ/cycle)

Cycle 9 GMT 19/11/2020 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 15.35 437 201 0.20 / 31.17 2 3
2 7 2003.12 33 15.13 2908 1452 1.65 / 32.62 2 3
3 13 1459.44 18 15.16 2234 610 2.26 / 33.23 2 3
4 13 1026.52 18 15.23 1669 458 2.72 / 33.69 2 2
5 13 278.36 18 15.36 664 184 2.90 / 33.87 2 3
6 8 0.08 175 15.38 273 735 3.64 / 34.61 2 4
Average= 3.46
(KJ/cycle)

Cycle 8 GMT 9/11/2020 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 15.35 431 192 0.19 / 27.55 2 3
2 7 2004.56 33 15.13 2910 1453 1.64 / 29.00 2 3
3 13 1441.60 18 15.18 2210 604 2.25 / 29.60 2 3
4 13 998.04 18 15.24 1632 448 2.70 / 30.05 2 3
5 13 263.68 18 15.37 644 178 2.87 / 30.23 2 3
6 8 0.12 175 15.39 274 738 3.61 / 30.97 2 5
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 30/10/2020 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 29 15.36 440 196 0.20 / 23.87 2 3
2 7 2004.60 34 15.13 2908 1496 1.69 / 25.37 2 3
3 13 1560.60 18 15.17 2364 646 2.34 / 26.01 2 3
4 13 963.32 18 15.24 1581 434 2.77 / 26.44 2 3
5 13 217.72 18 15.38 582 161 2.93 / 26.61 2 3
6 8 0.08 175 15.39 278 749 3.68 / 27.35 2 3
Average= 3.42
(KJ/cycle)

Cycle 6 GMT 20/10/2020 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 28 15.36 447 192 0.19 / 20.23 2 2
2 10 1003.60 2 15.37 1683 52 0.24 / 20.28 2 3
3 7 2004.48 38 15.12 2913 1674 1.92 / 21.95 2 4
4 13 1285.04 18 15.22 2011 551 2.47 / 22.50 2 3
5 13 723.08 18 15.30 1269 349 2.82 / 22.85 2 3
6 13 61.20 18 15.42 378 105 2.92 / 22.96 2 2
7 8 0.16 165 15.40 281 714 3.64 / 23.67 2 5
Average= 3.38
(KJ/cycle)

Cycle 5 GMT 10/10/2020 23:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 26 15.33 468 187 0.19 / 16.54 2 3
2 10 1023.48 2 15.33 1717 53 0.24 / 16.60 2 3
3 7 2002.96 38 15.12 2908 1671 1.91 / 18.27 2 3
4 13 1386.60 18 15.19 2136 584 2.49 / 18.85 2 3
5 13 798.08 18 15.27 1362 374 2.87 / 19.22 2 4
6 13 45.40 18 15.42 353 98 2.97 / 19.32 2 2
7 8 0.16 165 15.40 281 714 3.68 / 20.04 2 6
Average= 3.34
(KJ/cycle)

Cycle 4 GMT 1/10/2020 2: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 28 15.32 465 199 0.20 / 12.60 2 2
2 7 1519.00 75 15.14 2283 2592 2.79 / 15.19 2 3
3 8 0.24 165 15.40 317 805 3.60 / 15.99 2 3
4 14 0.24 75 15.36 314 362 3.96 / 16.36 2 7
Average= 3.27
(KJ/cycle)

Cycle 3 GMT 30/ 9/2020 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.32 472 202 0.20 / 8.59 2 2
2 7 1514.24 74 15.14 2281 2556 2.76 / 11.15 2 4
3 13 45.88 18 15.42 386 107 2.87 / 11.26 2 2
4 8 0.04 165 15.39 309 785 3.65 / 12.04 2 3
5 14 0.04 75 15.35 310 357 4.01 / 12.40 2 9
Average= 3.10
(KJ/cycle)

Cycle 2 GMT 29/ 9/2020 2:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 28 15.31 456 195 0.20 / 4.92 2 2
2 7 1511.32 74 15.10 2302 2572 2.77 / 7.49 2 4
3 13 55.12 18 15.39 398 110 2.88 / 7.60 2 3
4 8 -0.08 165 15.37 310 786 3.66 / 8.39 2 3
Average= 2.80
(KJ/cycle)

Cycle 1 GMT 28/ 9/2020 3:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 24 15.48 461 171 0.17 / 2.05 2 3
2 10 1008.48 3 15.34 1724 79 0.25 / 2.13 2 5
3 3 1037.16 1 15.35 1761 27 0.28 / 2.16 2 3
4 7 1010.68 74 15.22 1626 1831 2.11 / 3.99 2 3
5 8 0.04 165 15.37 290 735 2.84 / 4.73 2 3
Average= 2.36
(KJ/cycle)

Cycle 0 GMT 27/ 9/2020 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.52 24 15.62 511 192 0.19 / 0.19 2 3
2 7 139.00 74 15.58 511 589 0.78 / 0.78 2 3
3 8 0.08 240 15.55 295 1101 1.88 / 1.88 2 4
Average= 1.88