SIO Argo Site:
Pump Diagnostics Page   



Serial= 7861 WMO= 4903549

Return

←PreviousNext→

Cycle 107 GMT 24/11/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 9 14.67 652 86 0.09 / 493.62 9 12
2 7 1765.80 40 14.32 2971 1702 1.79 / 495.32 12 14
3 13 1166.36 20 14.37 2261 650 2.44 / 495.97 10 15
4 13 435.16 20 14.56 1217 354 2.79 / 496.33 10 15
5 13 138.48 20 14.67 750 220 3.01 / 496.55 10 14
6 8 0.24 282 14.63 515 2125 5.14 / 498.67 10 186
Average= 4.62
(KJ/cycle)

Cycle 106 GMT 19/11/2024 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 9 14.66 680 90 0.09 / 488.37 9 11
2 7 1790.76 40 14.32 3015 1727 1.82 / 490.09 11 14
3 13 1138.48 20 14.37 2243 645 2.46 / 490.74 10 14
4 13 458.60 20 14.55 1280 372 2.83 / 491.11 10 15
5 13 158.92 20 14.65 795 233 3.07 / 491.34 10 15
6 13 84.20 20 14.67 660 194 3.26 / 491.54 10 14
7 8 -0.08 265 14.62 516 1999 5.26 / 493.54 11 213
Average= 4.61
(KJ/cycle)

Cycle 105 GMT 14/11/2024 10:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 9 14.64 670 88 0.09 / 483.24 8 11
2 7 1748.36 40 14.33 2976 1706 1.79 / 484.95 11 14
3 13 1050.24 20 14.40 2116 609 2.40 / 485.56 10 15
4 13 407.60 20 14.58 1169 341 2.74 / 485.90 10 15
5 13 153.36 20 14.66 773 227 2.97 / 486.13 10 15
6 8 0.08 282 14.64 521 2151 5.12 / 488.28 11 191
Average= 4.61
(KJ/cycle)

Cycle 104 GMT 9/11/2024 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 9 14.66 679 90 0.09 / 478.06 9 11
2 7 1757.12 40 14.34 2950 1692 1.78 / 479.75 13 14
3 13 1072.84 20 14.39 2132 614 2.40 / 480.36 10 15
4 13 472.32 20 14.55 1288 375 2.77 / 480.74 10 15
5 13 160.28 20 14.65 800 234 3.00 / 480.97 10 15
6 8 0.04 282 14.63 529 2182 5.19 / 483.15 11 196
Average= 4.60
(KJ/cycle)

Cycle 103 GMT 4/11/2024 9: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 9 14.64 659 87 0.09 / 472.92 9 11
2 7 1762.88 40 14.33 2979 1708 1.79 / 474.63 11 14
3 13 1092.52 20 14.39 2184 629 2.42 / 475.26 10 14
4 13 417.04 20 14.56 1206 351 2.77 / 475.61 10 15
5 13 122.08 20 14.68 723 212 2.99 / 475.82 10 14
6 8 0.04 282 14.64 520 2147 5.13 / 477.97 10 183
Average= 4.60
(KJ/cycle)

Cycle 102 GMT 30/10/2024 8: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 9 14.64 679 89 0.09 / 467.82 9 12
2 7 1767.40 40 14.34 2977 1708 1.80 / 469.53 12 14
3 13 1071.16 20 14.39 2131 613 2.41 / 470.15 10 15
4 13 440.32 20 14.56 1233 359 2.77 / 470.50 10 15
5 13 98.72 20 14.69 671 197 2.97 / 470.70 10 14
6 8 0.32 282 14.63 517 2133 5.10 / 472.83 10 190
Average= 4.59
(KJ/cycle)

Cycle 101 GMT 25/10/2024 7:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 9 14.65 649 86 0.09 / 462.68 9 11
2 7 1760.00 40 14.33 2951 1692 1.78 / 464.37 11 14
3 13 1064.80 20 14.40 2120 611 2.39 / 464.98 10 15
4 13 499.80 20 14.54 1320 384 2.77 / 465.37 10 15
5 13 105.44 20 14.68 702 206 2.98 / 465.57 10 14
6 8 0.08 282 14.63 524 2162 5.14 / 467.74 10 216
Average= 4.59
(KJ/cycle)

Cycle 100 GMT 20/10/2024 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 9 14.67 674 89 0.09 / 457.56 9 11
2 7 1741.96 40 14.34 2946 1690 1.78 / 459.25 11 14
3 13 1041.96 20 14.40 2103 606 2.38 / 459.85 10 15
4 13 442.48 20 14.56 1230 358 2.74 / 460.21 10 15
5 13 138.92 20 14.67 776 228 2.97 / 460.44 10 15
6 8 0.16 282 14.64 522 2155 5.13 / 462.60 11 232
Average= 4.58
(KJ/cycle)

Cycle 99 GMT 15/10/2024 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 9 14.67 665 88 0.09 / 452.41 9 11
2 3 1518.76 1 14.55 2804 41 0.13 / 452.45 9 13
3 7 1787.08 40 14.34 2978 1708 1.84 / 454.16 13 14
4 13 1132.72 20 14.38 2211 636 2.47 / 454.79 10 14
5 13 525.88 20 14.54 1352 393 2.87 / 455.19 10 15
6 13 172.56 20 14.67 784 230 3.10 / 455.42 10 14
7 8 0.16 282 14.66 497 2055 5.15 / 457.47 11 170
Average= 4.57
(KJ/cycle)

Cycle 98 GMT 10/10/2024 4:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 9 14.65 653 86 0.09 / 447.22 8 11
2 7 1793.56 40 14.33 3016 1729 1.81 / 448.94 11 14
3 13 1147.44 20 14.39 2230 642 2.46 / 449.59 10 15
4 13 499.96 20 14.55 1340 390 2.85 / 449.98 10 15
5 13 151.08 20 14.68 779 229 3.08 / 450.20 10 15
6 8 0.08 282 14.65 512 2115 5.19 / 452.32 11 214
Average= 4.57
(KJ/cycle)

Cycle 97 GMT 5/10/2024 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 9 14.62 671 88 0.09 / 442.12 9 11
2 7 1760.96 40 14.35 2955 1696 1.78 / 443.82 11 14
3 13 1092.40 20 14.41 2159 622 2.41 / 444.44 10 15
4 13 508.52 20 14.54 1349 392 2.80 / 444.83 10 15
5 13 66.64 20 14.70 640 188 2.99 / 445.02 10 15
6 8 0.00 280 14.64 514 2107 5.09 / 447.13 10 190
Average= 4.56
(KJ/cycle)

Cycle 96 GMT 30/ 9/2024 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 9 14.67 662 87 0.09 / 436.99 9 10
2 7 1782.96 40 14.34 2968 1702 1.79 / 438.69 13 14
3 13 1181.60 20 14.39 2281 656 2.45 / 439.35 10 14
4 13 504.84 20 14.54 1327 386 2.83 / 439.73 10 15
5 13 58.48 20 14.70 625 184 3.02 / 439.92 10 16
6 13 15.28 20 14.71 552 162 3.18 / 440.08 10 15
7 8 0.04 261 14.63 512 1955 5.13 / 442.04 11 190
Average= 4.56
(KJ/cycle)

Cycle 95 GMT 25/ 9/2024 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 9 14.65 641 85 0.08 / 431.99 8 11
2 7 1788.12 40 14.35 2963 1701 1.79 / 433.69 11 14
3 13 1096.44 20 14.41 2148 619 2.40 / 434.31 10 14
4 13 353.60 20 14.61 1075 314 2.72 / 434.62 10 15
5 13 101.00 20 14.70 675 198 2.92 / 434.82 10 14
6 13 15.12 20 14.73 537 158 3.08 / 434.98 11 14
7 8 0.08 261 14.65 503 1923 5.00 / 436.90 11 225
Average= 4.55
(KJ/cycle)

Cycle 94 GMT 20/ 9/2024 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 9 14.65 650 86 0.09 / 426.97 9 11
2 7 1775.08 40 14.35 2948 1692 1.78 / 428.66 11 13
3 13 1106.08 20 14.41 2160 623 2.40 / 429.29 10 15
4 13 483.36 20 14.55 1290 375 2.78 / 429.66 10 15
5 13 42.12 20 14.71 586 172 2.95 / 429.83 10 15
6 8 0.08 280 14.64 505 2070 5.02 / 431.90 11 194
Average= 4.55
(KJ/cycle)

Cycle 93 GMT 15/ 9/2024 0:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 9 14.66 666 88 0.09 / 421.99 9 12
2 7 1761.60 40 14.34 2958 1697 1.78 / 423.68 12 14
3 13 1034.24 20 14.42 2072 598 2.38 / 424.28 10 14
4 13 365.28 20 14.59 1115 325 2.71 / 424.61 10 16
5 13 56.40 20 14.70 621 183 2.89 / 424.79 10 16
6 8 0.00 280 14.64 511 2095 4.98 / 426.88 10 231
Average= 4.54
(KJ/cycle)

Cycle 92 GMT 9/ 9/2024 23:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 9 14.68 639 84 0.08 / 417.04 9 11
2 7 1766.64 40 14.35 2948 1692 1.78 / 418.73 11 14
3 13 1106.44 20 14.41 2132 614 2.39 / 419.35 10 15
4 13 389.60 20 14.60 1125 328 2.72 / 419.68 10 15
5 13 97.48 20 14.70 674 198 2.92 / 419.87 10 15
6 8 0.00 282 14.66 490 2026 4.94 / 421.90 10 190
Average= 4.54
(KJ/cycle)

Cycle 91 GMT 4/ 9/2024 22:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 9 14.69 651 86 0.09 / 412.04 9 11
2 7 1779.36 40 14.34 2973 1705 1.79 / 413.75 11 14
3 13 1046.68 20 14.43 2067 597 2.39 / 414.35 10 15
4 13 451.32 20 14.58 1234 360 2.75 / 414.71 10 15
5 13 137.36 20 14.69 740 217 2.97 / 414.92 10 15
6 8 0.04 282 14.66 492 2034 5.00 / 416.96 11 196
Average= 4.53
(KJ/cycle)

Cycle 90 GMT 30/ 8/2024 21:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 9 14.66 639 84 0.08 / 407.11 9 11
2 7 1747.84 41 14.36 2918 1718 1.80 / 408.83 11 14
3 13 1048.00 20 14.43 2094 604 2.41 / 409.44 10 15
4 13 361.32 20 14.62 1098 321 2.73 / 409.76 10 15
5 13 109.32 20 14.70 684 201 2.93 / 409.96 10 15
6 8 0.08 280 14.67 487 2000 4.93 / 411.96 11 169
Average= 4.53
(KJ/cycle)

Cycle 89 GMT 25/ 8/2024 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 9 14.66 648 85 0.09 / 402.10 9 11
2 7 1758.40 40 14.37 2941 1690 1.78 / 403.79 11 14
3 13 1101.32 20 14.41 2184 629 2.41 / 404.42 10 15
4 13 424.04 20 14.58 1219 355 2.76 / 404.78 10 15
5 13 36.20 20 14.73 585 172 2.93 / 404.95 10 15
6 8 0.04 282 14.65 503 2078 5.01 / 407.03 11 215
Average= 4.52
(KJ/cycle)

Cycle 88 GMT 20/ 8/2024 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 9 14.68 661 87 0.09 / 397.08 9 11
2 7 1765.36 40 14.36 2946 1692 1.78 / 398.78 11 14
3 13 1063.52 20 14.42 2109 608 2.39 / 399.39 10 14
4 13 382.84 20 14.59 1136 331 2.72 / 399.72 10 15
5 13 80.52 20 14.70 680 200 2.92 / 399.92 10 15
6 13 25.12 20 14.71 594 175 3.09 / 400.09 10 15
7 8 0.04 261 14.64 504 1926 5.02 / 402.02 11 196
Average= 4.52
(KJ/cycle)

Cycle 87 GMT 15/ 8/2024 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 9 14.67 658 87 0.09 / 391.95 9 11
2 7 1836.16 40 14.35 3043 1747 1.83 / 393.70 11 14
3 13 1155.72 20 14.41 2211 637 2.47 / 394.34 10 14
4 13 518.76 20 14.57 1326 386 2.86 / 394.72 10 15
5 13 128.32 20 14.70 720 212 3.07 / 394.93 10 15
6 13 28.40 20 14.74 545 161 3.23 / 395.10 10 14
7 8 0.08 263 14.67 493 1902 5.13 / 397.00 11 179
Average= 4.51
(KJ/cycle)

Cycle 86 GMT 10/ 8/2024 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 9 14.67 665 88 0.09 / 386.87 9 11
2 7 1806.20 40 14.36 3009 1728 1.82 / 388.59 11 14
3 13 1140.96 20 14.42 2209 637 2.45 / 389.23 10 15
4 13 455.76 20 14.58 1236 360 2.81 / 389.59 10 15
5 13 85.80 20 14.70 682 201 3.01 / 389.79 10 15
6 13 11.00 20 14.74 535 158 3.17 / 389.95 10 14
7 8 0.00 261 14.65 501 1916 5.09 / 391.87 11 169
Average= 4.50
(KJ/cycle)

Cycle 85 GMT 5/ 8/2024 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 9 14.67 638 84 0.08 / 381.89 9 11
2 7 1761.72 40 14.38 2908 1673 1.76 / 383.56 11 14
3 13 1100.20 20 14.44 2127 614 2.37 / 384.17 10 15
4 13 492.40 20 14.57 1278 372 2.74 / 384.54 10 15
5 13 52.04 20 14.73 579 171 2.91 / 384.71 10 15
6 13 28.68 20 14.73 575 169 3.08 / 384.88 10 15
7 8 -0.12 261 14.66 495 1894 4.98 / 386.78 11 215
Average= 4.50
(KJ/cycle)

Cycle 84 GMT 31/ 7/2024 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 9 14.70 643 85 0.09 / 376.94 9 11
2 7 1783.20 40 14.36 2971 1707 1.79 / 378.64 11 14
3 13 1083.20 20 14.44 2102 607 2.40 / 379.25 10 15
4 13 480.88 20 14.58 1249 364 2.76 / 379.61 10 15
5 13 74.56 20 14.73 636 187 2.95 / 379.80 10 15
6 8 0.76 280 14.67 487 2000 4.95 / 381.80 11 184
Average= 4.49
(KJ/cycle)

Cycle 83 GMT 26/ 7/2024 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 9 14.69 646 85 0.09 / 371.93 9 11
2 7 1788.84 41 14.37 2956 1742 1.83 / 373.68 11 14
3 13 1241.04 20 14.41 2330 672 2.50 / 374.35 10 14
4 13 462.44 20 14.60 1245 364 2.86 / 374.71 10 15
5 13 119.60 20 14.72 685 202 3.06 / 374.91 10 15
6 8 0.00 280 14.69 471 1937 5.00 / 376.85 11 190
Average= 4.49
(KJ/cycle)

Cycle 82 GMT 21/ 7/2024 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 9 14.70 630 83 0.08 / 366.91 9 12
2 7 1768.32 40 14.39 2929 1686 1.77 / 368.60 12 14
3 13 1113.32 20 14.44 2155 622 2.39 / 369.22 10 15
4 13 534.52 20 14.57 1336 389 2.78 / 369.61 10 15
5 13 116.68 20 14.71 706 208 2.99 / 369.81 10 15
6 8 0.08 280 14.68 495 2035 5.02 / 371.85 11 191
Average= 4.48
(KJ/cycle)

Cycle 81 GMT 16/ 7/2024 13: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 9 14.70 626 83 0.08 / 362.01 9 11
2 7 1759.40 40 14.39 2918 1680 1.76 / 363.69 11 14
3 13 1133.44 20 14.45 2156 623 2.39 / 364.31 10 15
4 13 441.12 20 14.61 1201 351 2.74 / 364.67 10 15
5 13 123.12 20 14.72 703 207 2.94 / 364.87 10 15
6 8 0.12 280 14.69 475 1954 4.90 / 366.83 11 210
Average= 4.47
(KJ/cycle)

Cycle 80 GMT 11/ 7/2024 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 9 14.68 640 85 0.08 / 357.08 9 11
2 7 1798.52 40 14.38 2976 1712 1.80 / 358.79 11 14
3 13 1101.40 20 14.45 2130 616 2.41 / 359.40 10 15
4 13 461.00 20 14.60 1239 362 2.77 / 359.77 10 15
5 13 78.96 20 14.74 653 193 2.97 / 359.96 10 15
6 8 0.12 280 14.69 479 1970 4.94 / 361.93 10 187
Average= 4.47
(KJ/cycle)

Cycle 79 GMT 6/ 7/2024 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 9 14.69 622 82 0.08 / 352.10 9 12
2 7 1766.76 40 14.39 2929 1686 1.77 / 353.79 12 14
3 13 1071.16 20 14.46 2093 605 2.37 / 354.39 10 15
4 13 459.44 20 14.60 1240 362 2.74 / 354.76 10 15
5 13 51.80 20 14.75 606 179 2.91 / 354.93 10 15
6 8 0.00 282 14.68 497 2057 4.97 / 356.99 10 202
Average= 4.46
(KJ/cycle)

Cycle 78 GMT 1/ 7/2024 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 9 14.68 656 87 0.09 / 347.17 8 11
2 7 1802.20 40 14.39 2948 1697 1.78 / 348.87 13 14
3 13 1079.96 20 14.46 2085 603 2.39 / 349.47 10 15
4 13 445.48 20 14.61 1202 351 2.74 / 349.82 10 15
5 13 48.88 20 14.75 587 173 2.91 / 349.99 10 15
6 8 0.08 282 14.69 489 2026 4.94 / 352.02 10 198
Average= 4.46
(KJ/cycle)

Cycle 77 GMT 26/ 6/2024 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 9 14.69 648 86 0.09 / 342.07 9 11
2 7 1808.44 40 14.37 2989 1718 1.80 / 343.79 11 14
3 13 1172.80 20 14.43 2236 645 2.45 / 344.44 10 15
4 13 524.52 20 14.58 1350 394 2.84 / 344.83 10 15
5 13 44.48 20 14.75 585 173 3.02 / 345.00 10 15
6 8 0.00 282 14.68 503 2082 5.10 / 347.08 10 172
Average= 4.45
(KJ/cycle)

Cycle 76 GMT 21/ 6/2024 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 9 14.69 646 85 0.09 / 336.98 9 11
2 7 1802.92 41 14.37 3003 1769 1.85 / 338.75 11 14
3 13 1074.28 20 14.45 2139 618 2.47 / 339.37 10 15
4 13 434.28 20 14.61 1237 361 2.83 / 339.73 10 15
5 13 40.92 20 14.75 597 176 3.01 / 339.90 10 15
6 8 0.04 282 14.68 503 2082 5.09 / 341.99 10 209
Average= 4.44
(KJ/cycle)

Cycle 75 GMT 16/ 6/2024 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 9 14.69 672 89 0.09 / 331.81 9 11
2 7 1794.52 40 14.39 3005 1730 1.82 / 333.54 11 14
3 13 1131.12 20 14.44 2218 641 2.46 / 334.18 10 15
4 13 511.24 20 14.59 1352 395 2.85 / 334.57 10 15
5 13 31.96 20 14.76 600 177 3.03 / 334.75 10 15
6 8 0.16 282 14.68 518 2144 5.18 / 336.89 11 207
Average= 4.43
(KJ/cycle)

Cycle 74 GMT 11/ 6/2024 6:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 9 14.69 644 85 0.09 / 326.61 9 12
2 7 1812.80 40 14.38 2996 1723 1.81 / 328.33 12 14
3 13 1158.68 20 14.44 2256 652 2.46 / 328.98 10 14
4 13 502.32 20 14.59 1335 390 2.85 / 329.37 10 15
5 13 34.92 20 14.76 611 180 3.03 / 329.55 10 15
6 8 0.04 282 14.68 523 2165 5.19 / 331.72 10 176
Average= 4.42
(KJ/cycle)

Cycle 73 GMT 6/ 6/2024 5:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 9 14.71 655 87 0.09 / 321.40 9 11
2 7 1839.92 40 14.37 3050 1753 1.84 / 323.15 11 14
3 13 1208.60 20 14.43 2299 663 2.50 / 323.82 10 15
4 13 597.24 20 14.57 1447 422 2.93 / 324.24 10 15
5 13 39.36 20 14.77 592 175 3.10 / 324.41 10 15
6 8 -0.04 285 14.69 504 2110 5.21 / 326.52 10 209
Average= 4.41
(KJ/cycle)

Cycle 72 GMT 1/ 6/2024 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 9 14.70 677 90 0.09 / 316.32 9 11
2 7 1788.84 40 14.40 2965 1708 1.80 / 318.03 11 14
3 13 1123.48 20 14.46 2181 631 2.43 / 318.66 10 15
4 13 478.04 20 14.61 1296 379 2.81 / 319.04 10 15
5 13 39.40 20 14.77 580 171 2.98 / 319.21 10 15
6 8 0.04 282 14.69 508 2104 5.08 / 321.31 11 217
Average= 4.40
(KJ/cycle)

Cycle 71 GMT 27/ 5/2024 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 9 14.70 657 87 0.09 / 311.32 9 11
2 7 1771.60 40 14.40 2953 1701 1.79 / 313.02 11 14
3 13 1043.32 20 14.49 2072 600 2.39 / 313.62 10 15
4 13 407.32 20 14.65 1150 337 2.73 / 313.96 10 15
5 13 28.40 20 14.78 560 166 2.89 / 314.12 10 15
6 8 0.04 282 14.70 509 2110 5.00 / 316.23 10 202
Average= 4.39
(KJ/cycle)

Cycle 70 GMT 22/ 5/2024 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 9 14.71 638 84 0.08 / 306.27 9 12
2 7 1771.92 40 14.41 2958 1705 1.79 / 307.98 12 14
3 13 1107.96 20 14.48 2148 622 2.41 / 308.60 10 15
4 13 448.52 20 14.63 1237 362 2.77 / 308.96 10 15
5 13 46.56 20 14.77 595 176 2.95 / 309.14 10 15
6 8 -0.08 282 14.70 505 2093 5.04 / 311.23 10 196
Average= 4.38
(KJ/cycle)

Cycle 69 GMT 17/ 5/2024 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 9 14.72 648 86 0.09 / 301.17 9 11
2 7 1798.92 41 14.40 2982 1761 1.85 / 302.93 13 14
3 13 1090.24 20 14.47 2138 619 2.47 / 303.55 10 15
4 13 458.40 20 14.63 1249 365 2.83 / 303.91 10 15
5 13 54.64 20 14.77 623 184 3.01 / 304.10 10 15
6 8 0.00 282 14.70 504 2089 5.10 / 306.19 11 205
Average= 4.37
(KJ/cycle)

Cycle 68 GMT 12/ 5/2024 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 9 14.72 648 86 0.09 / 296.13 9 12
2 7 1763.52 40 14.40 2958 1704 1.79 / 297.83 12 14
3 13 1075.20 20 14.48 2122 615 2.40 / 298.44 10 15
4 13 401.76 20 14.65 1177 345 2.75 / 298.79 10 15
5 13 47.80 20 14.78 607 179 2.93 / 298.97 10 15
6 8 0.00 280 14.70 514 2116 5.04 / 301.08 11 185
Average= 4.36
(KJ/cycle)

Cycle 67 GMT 6/ 5/2024 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 9 14.73 642 85 0.09 / 291.07 9 12
2 7 1779.96 40 14.41 2971 1712 1.80 / 292.78 12 14
3 13 1118.88 20 14.48 2158 625 2.42 / 293.41 10 15
4 13 463.32 20 14.64 1275 373 2.80 / 293.78 10 15
5 13 81.80 20 14.78 637 188 2.98 / 293.97 10 15
6 8 0.00 280 14.72 502 2069 5.05 / 296.04 10 197
Average= 4.35
(KJ/cycle)

Cycle 66 GMT 1/ 5/2024 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 9 14.71 687 91 0.09 / 286.09 9 12
2 7 1772.56 40 14.41 2960 1706 1.80 / 287.80 12 14
3 13 1053.60 20 14.49 2113 612 2.41 / 288.41 10 15
4 13 383.68 20 14.68 1132 332 2.74 / 288.74 10 15
5 13 128.76 20 14.77 725 214 2.96 / 288.96 10 15
6 8 0.04 280 14.73 492 2029 4.99 / 290.99 10 210
Average= 4.34
(KJ/cycle)

Cycle 65 GMT 26/ 4/2024 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 9 14.72 692 92 0.09 / 280.96 9 12
2 7 1784.44 40 14.40 2988 1721 1.81 / 282.68 12 14
3 13 1211.56 20 14.46 2303 666 2.48 / 283.35 10 15
4 13 487.64 20 14.65 1293 379 2.86 / 283.73 10 15
5 13 138.96 20 14.77 736 217 3.08 / 283.94 10 15
6 8 0.12 282 14.73 495 2056 5.13 / 286.00 10 188
Average= 4.33
(KJ/cycle)

Cycle 64 GMT 21/ 4/2024 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 9 14.73 681 90 0.09 / 275.92 9 12
2 7 1752.92 40 14.42 2938 1695 1.78 / 277.61 12 14
3 13 1065.36 20 14.49 2110 611 2.40 / 278.22 10 15
4 13 421.56 20 14.67 1188 349 2.74 / 278.57 10 15
5 13 115.56 20 14.77 711 210 2.95 / 278.78 10 15
6 8 0.16 280 14.73 506 2087 5.04 / 280.87 10 174
Average= 4.32
(KJ/cycle)

Cycle 63 GMT 16/ 4/2024 20: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 9 14.74 667 88 0.09 / 270.93 9 12
2 7 1779.84 40 14.41 2971 1712 1.80 / 272.64 13 14
3 13 1086.76 20 14.50 2128 617 2.42 / 273.26 10 15
4 13 418.04 20 14.68 1167 343 2.76 / 273.60 10 15
5 13 117.80 20 14.78 697 206 2.97 / 273.81 10 15
6 8 0.16 280 14.74 490 2022 4.99 / 275.83 10 167
Average= 4.31
(KJ/cycle)

Cycle 62 GMT 11/ 4/2024 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 9 14.71 658 87 0.09 / 265.86 9 12
2 7 1774.96 40 14.42 2967 1711 1.80 / 267.57 12 14
3 13 1085.68 20 14.50 2144 622 2.42 / 268.19 10 15
4 13 475.76 20 14.66 1290 378 2.80 / 268.57 10 15
5 13 120.56 20 14.78 730 216 3.01 / 268.78 10 15
6 8 0.12 280 14.74 498 2055 5.07 / 270.84 11 163
Average= 4.30
(KJ/cycle)

Cycle 61 GMT 6/ 4/2024 18:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 9 14.73 630 84 0.08 / 260.70 9 12
2 7 1840.48 40 14.39 3046 1753 1.84 / 262.45 12 14
3 13 1159.44 20 14.48 2218 642 2.48 / 263.09 10 15
4 13 586.24 20 14.61 1432 418 2.90 / 263.51 10 15
5 13 54.64 20 14.80 594 176 3.07 / 263.69 10 15
6 8 0.08 282 14.72 502 2084 5.16 / 265.77 11 165
Average= 4.29
(KJ/cycle)

Cycle 60 GMT 1/ 4/2024 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 9 14.73 646 86 0.09 / 255.65 9 12
2 7 1796.52 40 14.42 2986 1722 1.81 / 257.38 12 14
3 13 1090.76 20 14.51 2133 619 2.43 / 258.00 10 15
4 13 473.08 20 14.64 1277 374 2.80 / 258.37 10 15
5 13 32.12 20 14.80 586 173 2.97 / 258.54 10 15
6 8 -0.04 280 14.72 502 2069 5.04 / 260.61 11 186
Average= 4.27
(KJ/cycle)

Cycle 59 GMT 27/ 3/2024 16:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 9 14.73 649 86 0.09 / 250.56 9 12
2 7 1811.24 40 14.42 2996 1728 1.81 / 252.29 12 14
3 13 1218.00 20 14.49 2277 660 2.47 / 252.95 10 15
4 13 501.04 20 14.64 1302 381 2.86 / 253.33 10 15
5 13 31.56 20 14.81 553 164 3.02 / 253.49 10 15
6 8 0.12 282 14.73 500 2077 5.10 / 255.57 10 174
Average= 4.26
(KJ/cycle)

Cycle 58 GMT 22/ 3/2024 15:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 9 14.75 659 87 0.09 / 245.54 9 12
2 7 1800.12 40 14.42 2972 1714 1.80 / 247.26 12 14
3 13 1253.88 20 14.48 2304 667 2.47 / 247.92 10 14
4 13 407.80 20 14.68 1174 345 2.81 / 248.27 10 15
5 13 36.00 20 14.81 563 167 2.98 / 248.43 10 15
6 8 0.12 280 14.74 494 2039 5.02 / 250.47 10 153
Average= 4.25
(KJ/cycle)

Cycle 57 GMT 17/ 3/2024 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 9 14.75 632 84 0.08 / 240.56 9 12
2 7 1795.12 41 14.42 2960 1750 1.83 / 242.31 12 14
3 13 1128.84 20 14.51 2157 626 2.46 / 242.94 10 15
4 13 469.04 20 14.67 1240 364 2.82 / 243.30 10 15
5 13 83.24 20 14.80 636 188 3.01 / 243.49 10 15
6 8 -0.04 280 14.75 475 1962 4.97 / 245.45 11 179
Average= 4.23
(KJ/cycle)

Cycle 56 GMT 12/ 3/2024 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 9 14.76 628 83 0.08 / 235.67 9 12
2 7 1775.68 40 14.43 2949 1702 1.79 / 237.38 12 14
3 13 1043.72 20 14.52 2064 599 2.38 / 237.98 10 15
4 13 445.52 20 14.67 1217 357 2.74 / 238.33 10 15
5 13 25.08 20 14.82 542 161 2.90 / 238.49 10 15
6 8 0.16 280 14.75 481 1987 4.89 / 240.48 10 198
Average= 4.22
(KJ/cycle)

Cycle 55 GMT 7/ 3/2024 12:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 9 14.77 630 84 0.08 / 230.76 9 12
2 7 1792.92 40 14.43 2961 1709 1.79 / 232.47 12 14
3 13 1121.92 20 14.51 2157 626 2.42 / 233.10 10 15
4 13 472.20 20 14.68 1240 364 2.78 / 233.46 10 15
5 13 49.44 20 14.83 558 166 2.95 / 233.63 10 15
6 8 0.00 280 14.76 475 1963 4.91 / 235.59 11 192
Average= 4.21
(KJ/cycle)

Cycle 54 GMT 2/ 3/2024 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 9 14.75 626 83 0.08 / 225.91 9 12
2 7 1768.00 40 14.44 2933 1694 1.78 / 227.61 12 14
3 13 1088.20 20 14.53 2114 614 2.39 / 228.22 10 15
4 13 403.12 20 14.70 1140 335 2.73 / 228.56 10 15
5 13 59.12 20 14.82 593 176 2.90 / 228.73 10 15
6 8 0.12 278 14.77 474 1946 4.85 / 230.68 10 169
Average= 4.19
(KJ/cycle)

Cycle 53 GMT 26/ 2/2024 10:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 9 14.77 631 84 0.08 / 221.07 9 12
2 7 1775.88 40 14.44 2937 1696 1.78 / 222.77 12 14
3 13 1024.36 20 14.54 2036 592 2.37 / 223.36 10 15
4 13 391.36 20 14.70 1110 326 2.70 / 223.69 10 15
5 13 35.68 20 14.83 550 163 2.86 / 223.85 10 15
6 8 -0.04 278 14.75 483 1981 4.84 / 225.83 11 172
Average= 4.18
(KJ/cycle)

Cycle 52 GMT 21/ 2/2024 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 9 14.77 622 83 0.08 / 216.33 9 12
2 7 1782.92 40 14.45 2916 1685 1.77 / 218.01 12 14
3 13 976.84 20 14.55 1941 565 2.33 / 218.58 10 15
4 13 414.28 20 14.70 1128 332 2.66 / 218.91 10 15
5 13 57.32 20 14.83 557 165 2.83 / 219.07 10 15
6 8 0.04 278 14.77 466 1913 4.74 / 220.99 11 210
Average= 4.17
(KJ/cycle)

Cycle 51 GMT 16/ 2/2024 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 9 14.77 599 80 0.08 / 211.52 9 12
2 7 1808.92 40 14.45 2943 1701 1.78 / 213.22 12 14
3 13 1099.96 20 14.53 2092 608 2.39 / 213.82 10 15
4 13 463.76 20 14.69 1200 353 2.74 / 214.18 10 15
5 13 61.36 20 14.83 556 165 2.91 / 214.34 10 15
6 8 0.08 278 14.78 463 1902 4.81 / 216.24 11 175
Average= 4.16
(KJ/cycle)

Cycle 50 GMT 11/ 2/2024 7:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 9 14.78 629 84 0.08 / 206.77 9 12
2 7 1774.44 40 14.46 2867 1658 1.74 / 208.43 12 14
3 13 1058.88 20 14.55 2020 588 2.33 / 209.02 10 15
4 13 519.08 20 14.67 1269 372 2.70 / 209.39 10 15
5 13 29.20 20 14.85 505 150 2.85 / 209.54 10 15
6 8 0.00 280 14.77 459 1898 4.75 / 211.44 12 181
Average= 4.15
(KJ/cycle)

Cycle 49 GMT 6/ 2/2024 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 9 14.79 582 77 0.08 / 202.14 9 12
2 7 1843.24 40 14.44 2943 1700 1.78 / 203.84 12 14
3 13 1012.92 20 14.56 1945 566 2.34 / 204.40 10 15
4 13 397.80 20 14.72 1072 316 2.66 / 204.72 10 15
5 13 46.36 20 14.84 505 150 2.81 / 204.87 10 15
6 8 0.04 280 14.78 439 1817 4.63 / 206.69 11 170
Average= 4.13
(KJ/cycle)

Cycle 48 GMT 1/ 2/2024 5:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 9 14.79 572 76 0.08 / 197.54 9 12
2 7 1805.68 40 14.45 2895 1673 1.75 / 199.22 12 14
3 13 1068.52 20 14.55 2011 585 2.33 / 199.80 10 15
4 13 452.64 20 14.70 1141 335 2.67 / 200.14 10 16
5 13 27.64 20 14.86 478 142 2.81 / 200.28 10 15
6 8 0.08 280 14.79 430 1781 4.59 / 202.06 10 194
Average= 4.12
(KJ/cycle)

Cycle 47 GMT 27/ 1/2024 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 9 14.81 574 77 0.08 / 193.02 9 12
2 7 1788.68 41 14.46 2851 1690 1.77 / 194.71 12 14
3 13 985.32 20 14.58 1884 549 2.32 / 195.26 10 15
4 13 386.32 20 14.73 1033 304 2.62 / 195.56 10 15
5 13 66.52 20 14.84 526 156 2.78 / 195.72 10 15
6 8 -0.04 278 14.79 426 1752 4.53 / 197.47 10 196
Average= 4.11
(KJ/cycle)

Cycle 46 GMT 22/ 1/2024 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 10 14.82 558 83 0.08 / 188.62 9 12
2 7 1771.52 40 14.47 2827 1636 1.72 / 190.26 12 14
3 13 1068.24 20 14.57 1984 578 2.30 / 190.84 10 15
4 13 341.20 20 14.77 940 278 2.57 / 191.12 10 15
5 13 93.48 20 14.85 549 163 2.74 / 191.28 10 15
6 8 0.20 278 14.82 403 1660 4.40 / 192.94 10 188
Average= 4.11
(KJ/cycle)

Cycle 45 GMT 17/ 1/2024 2:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 9 14.83 560 75 0.07 / 184.20 9 12
2 7 1776.48 41 14.47 2834 1681 1.76 / 185.88 12 14
3 13 1115.92 20 14.56 2028 591 2.35 / 186.47 10 15
4 13 386.44 20 14.76 1005 297 2.64 / 186.76 10 15
5 13 126.48 20 14.85 595 177 2.82 / 186.94 10 15
6 8 0.12 278 14.83 388 1600 4.42 / 188.54 10 196
Average= 4.10
(KJ/cycle)

Cycle 44 GMT 12/ 1/2024 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 9 14.83 553 74 0.07 / 179.74 9 12
2 7 1798.84 40 14.47 2858 1654 1.73 / 181.39 12 14
3 13 1109.32 20 14.57 2014 587 2.31 / 181.98 10 15
4 13 539.64 20 14.71 1228 361 2.68 / 182.34 10 15
5 13 115.64 20 14.86 570 169 2.85 / 182.51 10 15
6 8 0.08 278 14.83 391 1612 4.46 / 184.12 11 156
Average= 4.09
(KJ/cycle)

Cycle 43 GMT 7/ 1/2024 0:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 10 14.83 557 83 0.08 / 175.30 9 12
2 7 1784.44 40 14.48 2844 1647 1.73 / 176.94 12 14
3 13 1142.48 20 14.56 2082 606 2.34 / 177.55 10 15
4 13 462.00 20 14.74 1114 328 2.66 / 177.88 10 15
5 13 155.48 20 14.84 639 190 2.85 / 178.07 10 15
6 8 0.04 278 14.83 387 1596 4.45 / 179.66 10 159
Average= 4.08
(KJ/cycle)

Cycle 42 GMT 1/ 1/2024 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 10 14.83 555 82 0.08 / 170.92 9 12
2 7 1794.60 40 14.48 2831 1640 1.72 / 172.56 12 14
3 13 1133.52 20 14.57 2041 595 2.32 / 173.15 10 15
4 13 421.88 20 14.76 1039 307 2.62 / 173.46 10 15
5 13 124.60 20 14.86 580 172 2.80 / 173.63 10 15
6 8 0.20 278 14.84 384 1584 4.38 / 175.21 11 169
Average= 4.07
(KJ/cycle)

Cycle 41 GMT 27/12/2023 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 10 14.83 551 82 0.08 / 166.56 9 12
2 7 1778.44 41 14.49 2808 1668 1.75 / 168.22 12 14
3 13 1100.40 20 14.58 1998 583 2.33 / 168.81 10 15
4 13 366.48 20 14.78 951 281 2.61 / 169.09 10 15
5 13 117.68 20 14.86 569 169 2.78 / 169.26 10 15
6 8 -0.04 278 14.84 382 1576 4.36 / 170.83 11 148
Average= 4.07
(KJ/cycle)

Cycle 40 GMT 22/12/2023 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 10 14.84 550 82 0.08 / 162.12 9 12
2 7 1791.72 40 14.49 2829 1640 1.72 / 163.76 12 14
3 13 1098.84 20 14.58 2006 585 2.31 / 164.35 10 15
4 13 459.64 20 14.73 1112 328 2.63 / 164.67 10 15
5 13 108.96 20 14.86 556 165 2.80 / 164.84 10 15
6 8 0.16 280 14.83 394 1636 4.44 / 166.48 10 179
Average= 4.06
(KJ/cycle)

Cycle 39 GMT 17/12/2023 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 10 14.85 525 78 0.08 / 157.83 9 12
2 7 1759.72 40 14.50 2782 1614 1.69 / 159.45 12 14
3 13 1039.16 20 14.60 1906 557 2.25 / 160.00 10 15
4 13 436.36 20 14.76 1068 315 2.56 / 160.32 10 15
5 13 91.48 20 14.87 528 157 2.72 / 160.48 10 15
6 8 -0.08 278 14.85 379 1565 4.29 / 162.04 11 163
Average= 4.05
(KJ/cycle)

Cycle 38 GMT 12/12/2023 20: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 10 14.86 535 80 0.08 / 153.46 9 12
2 7 1804.08 40 14.49 2838 1645 1.72 / 155.11 12 14
3 13 1113.48 20 14.59 2003 584 2.31 / 155.69 10 15
4 13 473.80 20 14.75 1107 327 2.64 / 156.02 10 15
5 13 122.84 20 14.87 569 169 2.80 / 156.19 10 15
6 8 0.12 280 14.85 377 1568 4.37 / 157.75 10 179
Average= 4.04
(KJ/cycle)

Cycle 37 GMT 7/12/2023 19: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 10 14.85 534 79 0.08 / 149.14 9 12
2 7 1798.64 40 14.50 2812 1631 1.71 / 150.77 12 14
3 13 1146.20 20 14.59 2026 591 2.30 / 151.36 10 15
4 13 429.28 20 14.78 1034 306 2.61 / 151.67 10 15
5 13 132.84 20 14.87 581 173 2.78 / 151.84 10 15
6 8 0.12 280 14.86 371 1544 4.32 / 153.38 10 184
Average= 4.04
(KJ/cycle)

Cycle 36 GMT 2/12/2023 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 10 14.84 537 80 0.08 / 144.87 9 12
2 7 1758.08 40 14.52 2771 1609 1.69 / 146.48 12 14
3 13 1063.60 20 14.61 1938 566 2.26 / 147.05 10 15
4 13 428.44 20 14.77 1042 308 2.56 / 147.36 10 15
5 13 87.12 20 14.89 500 149 2.71 / 147.51 10 15
6 8 0.00 278 14.86 376 1553 4.27 / 149.06 11 159
Average= 4.03
(KJ/cycle)

Cycle 35 GMT 27/11/2023 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 10 14.84 543 81 0.08 / 140.57 9 12
2 7 1795.16 40 14.51 2808 1630 1.71 / 142.20 12 14
3 13 1087.56 20 14.61 1958 572 2.28 / 142.78 10 15
4 13 414.52 20 14.77 1009 298 2.58 / 143.07 10 15
5 13 63.52 20 14.89 467 139 2.72 / 143.21 10 15
6 8 -0.04 278 14.85 383 1581 4.30 / 144.79 10 157
Average= 4.02
(KJ/cycle)

Cycle 34 GMT 22/11/2023 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 10 14.85 543 81 0.08 / 136.23 9 12
2 7 1810.04 40 14.50 2826 1639 1.72 / 137.87 12 14
3 13 1142.44 20 14.59 2032 593 2.31 / 138.46 10 15
4 13 425.96 20 14.76 1032 305 2.62 / 138.76 10 15
5 13 52.08 20 14.90 446 133 2.75 / 138.90 10 15
6 8 0.08 280 14.85 384 1597 4.35 / 140.49 11 196
Average= 4.01
(KJ/cycle)

Cycle 33 GMT 17/11/2023 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 10 14.85 521 77 0.08 / 131.96 9 12
2 7 1791.40 40 14.52 2799 1626 1.70 / 133.58 12 14
3 13 1026.36 20 14.63 1870 547 2.25 / 134.13 10 15
4 13 493.16 20 14.76 1123 332 2.58 / 134.46 10 15
5 13 78.36 20 14.90 485 145 2.73 / 134.61 10 15
6 8 0.00 278 14.86 373 1541 4.27 / 136.15 11 185
Average= 4.00
(KJ/cycle)

Cycle 32 GMT 12/11/2023 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 10 14.85 523 78 0.08 / 127.71 9 12
2 7 1792.36 40 14.52 2801 1627 1.70 / 129.34 12 14
3 13 1041.88 20 14.62 1889 552 2.26 / 129.89 10 15
4 13 411.76 20 14.78 1008 298 2.55 / 130.19 10 15
5 13 61.56 20 14.90 460 137 2.69 / 130.32 10 15
6 8 0.04 280 14.85 374 1555 4.25 / 131.88 11 184
Average= 4.00
(KJ/cycle)

Cycle 31 GMT 7/11/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 10 14.88 516 77 0.08 / 123.39 9 12
2 7 1788.08 40 14.52 2803 1628 1.70 / 125.02 12 14
3 13 1110.68 20 14.61 1983 579 2.28 / 125.60 10 15
4 13 540.64 20 14.73 1197 353 2.64 / 125.95 10 15
5 13 53.40 20 14.90 447 133 2.77 / 126.09 10 15
6 8 0.12 280 14.85 372 1547 4.32 / 127.63 11 163
Average= 3.99
(KJ/cycle)

Cycle 30 GMT 2/11/2023 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 10 14.86 510 76 0.08 / 119.12 9 12
2 7 1797.92 40 14.52 2809 1631 1.71 / 120.75 12 14
3 13 1160.60 20 14.61 2045 598 2.30 / 121.35 10 15
4 13 470.24 20 14.78 1085 321 2.63 / 121.67 10 15
5 13 125.04 20 14.90 546 163 2.79 / 121.83 10 15
6 8 0.12 280 14.88 356 1483 4.27 / 123.32 11 181
Average= 3.98
(KJ/cycle)

Cycle 29 GMT 28/10/2023 11:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 10 14.87 516 77 0.08 / 114.79 9 12
2 7 1804.40 40 14.53 2804 1630 1.71 / 116.42 12 14
3 13 1148.20 20 14.61 2015 589 2.30 / 117.01 10 15
4 13 599.88 20 14.72 1272 374 2.67 / 117.38 10 15
5 13 102.36 20 14.89 518 154 2.82 / 117.54 10 15
6 8 0.08 282 14.87 359 1505 4.33 / 119.04 11 196
Average= 3.97
(KJ/cycle)

Cycle 28 GMT 23/10/2023 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 10 14.88 498 74 0.07 / 110.56 9 12
2 7 1794.96 40 14.53 2793 1623 1.70 / 112.19 12 14
3 13 1089.88 20 14.63 1950 571 2.27 / 112.76 10 15
4 13 457.84 20 14.78 1061 314 2.58 / 113.07 10 15
5 13 137.48 20 14.89 565 168 2.75 / 113.24 10 15
6 8 0.04 280 14.88 354 1475 4.22 / 114.71 11 176
Average= 3.96
(KJ/cycle)

Cycle 27 GMT 18/10/2023 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 10 14.89 478 71 0.07 / 106.33 9 12
2 7 1791.64 40 14.53 2787 1620 1.69 / 107.95 12 14
3 13 1160.72 20 14.61 2028 593 2.28 / 108.54 10 15
4 13 511.76 20 14.77 1133 335 2.62 / 108.87 10 15
5 13 129.00 20 14.90 538 160 2.78 / 109.03 10 15
6 13 58.36 20 14.92 428 128 2.91 / 109.16 11 14
7 8 0.20 261 14.89 342 1329 4.24 / 110.49 11 162
Average= 3.95
(KJ/cycle)

Cycle 26 GMT 13/10/2023 8:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 10 14.88 483 72 0.07 / 102.18 9 12
2 7 1788.32 40 14.54 2772 1612 1.68 / 103.80 12 14
3 13 1137.80 20 14.62 1988 581 2.27 / 104.38 10 15
4 13 520.48 20 14.78 1131 334 2.60 / 104.71 10 15
5 13 128.84 20 14.91 526 157 2.76 / 104.87 10 15
6 8 0.12 280 14.90 332 1385 4.14 / 106.25 11 159
Average= 3.94
(KJ/cycle)

Cycle 25 GMT 8/10/2023 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 10 14.87 500 74 0.07 / 98.01 9 11
2 7 1803.28 40 14.55 2778 1617 1.69 / 99.63 11 14
3 13 1076.20 20 14.64 1918 562 2.25 / 100.19 10 15
4 13 526.20 20 14.76 1153 340 2.59 / 100.53 10 15
5 13 124.48 20 14.90 533 159 2.75 / 100.69 10 15
6 13 24.08 20 14.93 367 110 2.86 / 100.80 11 15
7 8 -0.04 261 14.88 339 1317 4.18 / 102.11 11 189
Average= 3.93
(KJ/cycle)

Cycle 24 GMT 3/10/2023 6:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 10 14.89 465 69 0.07 / 93.86 9 12
2 7 1784.84 40 14.55 2759 1606 1.67 / 95.46 12 14
3 13 1066.32 20 14.65 1892 554 2.23 / 96.02 10 15
4 13 556.48 20 14.75 1199 354 2.58 / 96.37 10 16
5 13 58.40 20 14.92 430 128 2.71 / 96.50 10 15
6 13 32.72 20 14.92 388 116 2.83 / 96.61 10 15
7 8 -0.08 261 14.88 340 1320 4.15 / 97.93 11 149
Average= 3.92
(KJ/cycle)

Cycle 23 GMT 28/ 9/2023 5:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 10 14.90 492 73 0.07 / 89.74 9 12
2 7 1805.88 40 14.55 2784 1620 1.69 / 91.36 12 14
3 13 1083.92 20 14.65 1929 565 2.26 / 91.93 10 15
4 13 481.08 20 14.79 1077 319 2.58 / 92.25 10 15
5 13 128.36 20 14.91 531 158 2.74 / 92.40 10 15
6 13 25.28 20 14.94 364 109 2.84 / 92.51 11 15
7 8 0.04 263 14.90 325 1274 4.12 / 93.79 11 182
Average= 3.91
(KJ/cycle)

Cycle 22 GMT 23/ 9/2023 4:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 10 14.89 479 71 0.07 / 85.59 9 12
2 7 1787.40 40 14.56 2758 1606 1.68 / 87.19 12 14
3 13 1208.68 20 14.63 2069 605 2.28 / 87.80 10 15
4 13 551.76 20 14.77 1174 347 2.63 / 88.15 10 15
5 13 143.88 20 14.91 555 166 2.80 / 88.31 10 15
6 13 16.88 20 14.95 347 104 2.90 / 88.41 11 14
7 8 0.12 263 14.90 320 1254 4.15 / 89.67 10 178
Average= 3.90
(KJ/cycle)

Cycle 21 GMT 18/ 9/2023 4: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 10 14.88 475 71 0.07 / 81.46 9 12
2 7 1817.32 40 14.55 2786 1621 1.69 / 83.09 12 14
3 13 1113.80 20 14.65 1941 569 2.26 / 83.66 10 15
4 13 506.16 20 14.77 1116 330 2.59 / 83.98 10 15
5 13 52.44 20 14.92 424 127 2.72 / 84.11 10 15
6 13 18.48 20 14.93 366 109 2.83 / 84.22 10 15
7 8 0.00 263 14.88 331 1295 4.12 / 85.52 11 171
Average= 3.89
(KJ/cycle)

Cycle 20 GMT 13/ 9/2023 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 10 14.89 480 71 0.07 / 77.38 9 12
2 7 1783.64 40 14.56 2754 1604 1.68 / 78.99 12 14
3 13 1098.32 20 14.65 1941 569 2.24 / 79.55 10 15
4 13 455.04 20 14.79 1044 309 2.55 / 79.86 10 16
5 13 54.44 20 14.92 430 128 2.68 / 79.99 10 15
6 13 16.40 20 14.93 367 110 2.79 / 80.10 10 15
7 8 0.00 261 14.88 333 1293 4.08 / 81.39 11 146
Average= 3.88
(KJ/cycle)

Cycle 19 GMT 8/ 9/2023 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 10 14.91 452 67 0.07 / 73.34 9 12
2 7 1798.28 40 14.56 2763 1609 1.68 / 74.95 12 14
3 13 1100.80 20 14.65 1951 572 2.25 / 75.52 10 15
4 13 424.52 20 14.82 980 290 2.54 / 75.81 10 15
5 13 75.60 20 14.93 441 132 2.67 / 75.95 10 15
6 13 20.52 20 14.95 354 106 2.78 / 76.05 11 15
7 8 0.00 263 14.90 321 1258 4.03 / 77.31 11 181
Average= 3.87
(KJ/cycle)

Cycle 18 GMT 3/ 9/2023 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 10 14.92 449 67 0.07 / 69.32 9 12
2 7 1798.12 40 14.56 2769 1613 1.68 / 70.93 12 14
3 13 1076.36 20 14.66 1904 558 2.24 / 71.49 10 15
4 13 484.48 20 14.80 1067 316 2.55 / 71.81 10 15
5 13 133.88 20 14.92 524 156 2.71 / 71.96 10 15
6 13 15.40 20 14.96 332 99 2.81 / 72.06 11 14
7 8 0.16 263 14.92 309 1213 4.02 / 73.28 11 180
Average= 3.86
(KJ/cycle)

Cycle 17 GMT 29/ 8/2023 0: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 10 14.92 475 71 0.07 / 65.24 9 12
2 7 1810.76 40 14.57 2779 1620 1.69 / 66.86 13 14
3 13 1185.12 20 14.65 2029 594 2.28 / 67.45 10 15
4 13 504.72 20 14.81 1090 323 2.61 / 67.77 10 15
5 13 158.20 20 14.92 565 169 2.78 / 67.94 10 15
6 13 48.36 20 14.95 385 115 2.89 / 68.06 11 14
7 8 -0.12 263 14.92 305 1197 4.09 / 69.25 11 146
Average= 3.85
(KJ/cycle)

Cycle 16 GMT 23/ 8/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 10 14.91 455 68 0.07 / 61.23 9 12
2 7 1793.64 40 14.57 2762 1610 1.68 / 62.84 12 14
3 13 1112.60 20 14.67 1942 570 2.25 / 63.41 10 15
4 13 477.60 20 14.82 1049 311 2.56 / 63.72 10 15
5 13 133.92 20 14.93 521 156 2.71 / 63.87 10 15
6 13 31.96 20 14.96 358 107 2.82 / 63.98 11 14
7 8 0.08 263 14.92 302 1185 4.01 / 65.17 11 161
Average= 3.83
(KJ/cycle)

Cycle 15 GMT 18/ 8/2023 22: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 10 14.92 468 70 0.07 / 57.17 9 11
2 3 1522.16 1 14.76 2443 36 0.11 / 57.20 9 13
3 7 1805.36 40 14.58 2769 1615 1.72 / 58.82 13 14
4 13 1153.84 20 14.66 1979 580 2.30 / 59.40 10 15
5 13 507.24 20 14.80 1102 326 2.63 / 59.73 10 15
6 13 123.92 20 14.93 511 153 2.78 / 59.88 10 15
7 13 27.40 20 14.96 348 104 2.88 / 59.98 11 15
8 8 0.08 263 14.92 300 1177 4.06 / 61.16 11 155
Average= 3.82
(KJ/cycle)

Cycle 14 GMT 13/ 8/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 10 14.92 447 67 0.07 / 53.16 9 11
2 7 1794.96 40 14.59 2755 1608 1.67 / 54.76 11 14
3 13 1212.28 20 14.65 2057 603 2.28 / 55.37 10 15
4 13 487.00 20 14.81 1058 313 2.59 / 55.68 10 15
5 13 105.72 20 14.94 471 141 2.73 / 55.82 10 15
6 13 36.20 20 14.96 359 107 2.84 / 55.93 11 15
7 8 0.08 263 14.93 298 1170 4.01 / 57.10 11 166
Average= 3.81
(KJ/cycle)

Cycle 13 GMT 8/ 8/2023 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 10 14.92 435 65 0.06 / 49.18 9 11
2 7 1811.56 40 14.59 2764 1613 1.68 / 50.79 11 14
3 13 1127.24 20 14.67 1957 574 2.25 / 51.37 10 15
4 13 492.84 20 14.81 1073 318 2.57 / 51.68 10 15
5 13 59.20 20 14.95 407 122 2.69 / 51.81 10 15
6 13 20.00 20 14.96 344 103 2.79 / 51.91 11 15
7 13 9.16 20 14.96 323 97 2.89 / 52.00 11 15
8 8 0.04 244 14.92 298 1085 3.98 / 53.09 11 178
Average= 3.79
(KJ/cycle)

Cycle 12 GMT 3/ 8/2023 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 10 14.91 450 67 0.07 / 45.26 9 12
2 7 1790.68 40 14.59 2750 1605 1.67 / 46.87 12 14
3 13 1101.84 20 14.68 1915 562 2.23 / 47.43 10 15
4 13 498.76 20 14.81 1080 320 2.55 / 47.75 10 15
5 13 48.00 20 14.96 389 116 2.67 / 47.87 10 15
6 8 0.08 282 14.93 296 1246 3.92 / 49.11 10 157
Average= 3.78
(KJ/cycle)

Cycle 11 GMT 29/ 7/2023 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 11 14.92 440 72 0.07 / 41.30 9 11
2 7 1802.64 40 14.60 2746 1604 1.68 / 42.91 11 14
3 13 1116.92 20 14.67 1948 572 2.25 / 43.48 10 15
4 13 509.80 20 14.80 1109 328 2.58 / 43.81 10 15
5 13 64.28 20 14.95 410 123 2.70 / 43.93 10 15
6 13 15.24 20 14.96 333 100 2.80 / 44.03 10 15
7 8 -0.08 263 14.92 298 1169 3.97 / 45.20 11 162
Average= 3.77
(KJ/cycle)

Cycle 10 GMT 24/ 7/2023 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 11 14.91 450 74 0.07 / 37.37 9 11
2 7 1812.64 41 14.59 2755 1648 1.72 / 39.01 11 14
3 13 1119.52 20 14.68 1936 568 2.29 / 39.58 10 15
4 13 473.52 20 14.82 1031 306 2.60 / 39.89 10 15
5 13 39.16 20 14.96 361 108 2.70 / 40.00 10 15
6 8 0.04 285 14.93 290 1234 3.94 / 41.23 11 175
Average= 3.75
(KJ/cycle)

Cycle 9 GMT 19/ 7/2023 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 9 14.92 441 59 0.06 / 33.34 9 11
2 10 1505.48 3 14.69 2406 106 0.17 / 33.45 9 13
3 7 1805.16 40 14.60 2749 1605 1.77 / 35.05 13 14
4 13 1111.80 20 14.68 1935 568 2.34 / 35.62 10 15
5 13 404.68 20 14.83 947 281 2.62 / 35.90 10 15
6 13 48.44 20 14.95 393 118 2.74 / 36.02 10 15
7 13 11.08 20 14.96 328 98 2.84 / 36.12 10 15
8 8 0.04 263 14.92 299 1173 4.01 / 37.29 11 147
Average= 3.73
(KJ/cycle)

Cycle 8 GMT 14/ 7/2023 15: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 11 14.92 438 72 0.07 / 29.41 9 11
2 3 1467.72 -1 15.31 0 0 0.00 / 29.41 9 11
3 7 1797.04 40 14.61 2745 1604 1.68 / 31.01 11 14
4 13 1119.72 20 14.69 1934 568 2.24 / 31.58 10 15
5 13 519.52 20 14.80 1110 329 2.57 / 31.91 10 15
6 13 74.96 20 14.95 425 127 2.70 / 32.04 10 15
7 13 20.52 20 14.97 334 100 2.80 / 32.14 10 15
8 8 0.04 265 14.93 290 1147 3.95 / 33.28 11 164
Average= 3.70
(KJ/cycle)

Cycle 7 GMT 9/ 7/2023 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 10 14.92 457 68 0.07 / 25.41 9 11
2 7 1832.00 40 14.60 2783 1625 1.69 / 27.04 11 14
3 13 1183.96 20 14.67 2000 587 2.28 / 27.62 10 15
4 13 541.24 20 14.79 1141 338 2.62 / 27.96 10 15
5 13 57.40 20 14.95 396 118 2.74 / 28.08 10 15
6 13 13.92 20 14.97 328 98 2.83 / 28.18 10 15
7 8 4.48 265 14.92 293 1158 3.99 / 29.34 11 157
Average= 3.67
(KJ/cycle)

Cycle 6 GMT 4/ 7/2023 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 10 14.93 451 67 0.07 / 21.47 9 11
2 7 1827.44 40 14.60 2774 1620 1.69 / 23.09 11 14
3 13 1220.76 20 14.67 2044 600 2.29 / 23.69 10 15
4 13 497.88 20 14.82 1059 314 2.60 / 24.01 10 15
5 13 111.60 20 14.95 470 141 2.74 / 24.15 10 15
6 13 20.04 20 14.98 317 95 2.84 / 24.24 11 15
7 8 0.08 265 14.94 278 1101 3.94 / 25.34 10 165
Average= 3.62
(KJ/cycle)

Cycle 5 GMT 29/ 6/2023 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 11 14.93 418 69 0.07 / 17.58 9 11
2 7 1800.32 41 14.60 2746 1644 1.71 / 19.23 11 14
3 13 1106.84 20 14.69 1905 560 2.27 / 19.78 10 15
4 13 471.16 20 14.84 1011 300 2.57 / 20.09 10 15
5 13 165.08 20 14.93 544 162 2.73 / 20.25 10 15
6 13 22.36 20 14.98 311 93 2.83 / 20.34 11 14
7 8 0.00 263 14.95 271 1066 3.89 / 21.41 11 152
Average= 3.57
(KJ/cycle)

Cycle 4 GMT 24/ 6/2023 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 11 14.92 443 73 0.07 / 13.67 9 11
2 7 1835.72 40 14.61 2771 1619 1.69 / 15.29 11 14
3 13 1174.64 20 14.68 1999 587 2.28 / 15.87 10 15
4 13 533.56 20 14.81 1123 333 2.61 / 16.20 10 15
5 13 183.00 20 14.93 571 171 2.78 / 16.38 10 15
6 13 19.04 20 14.98 306 92 2.87 / 16.47 11 14
7 8 0.08 265 14.95 264 1046 3.92 / 17.51 11 158
Average= 3.50
(KJ/cycle)

Cycle 3 GMT 19/ 6/2023 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 11 14.92 402 66 0.07 / 9.82 9 11
2 7 1809.80 40 14.63 2740 1603 1.67 / 11.42 11 14
3 13 1134.12 20 14.69 1929 567 2.24 / 11.99 10 15
4 13 527.56 20 14.82 1093 324 2.56 / 12.32 10 15
5 13 134.56 20 14.94 483 144 2.70 / 12.46 10 15
6 13 30.20 20 14.98 308 92 2.80 / 12.55 11 15
7 8 0.04 265 14.94 263 1041 3.84 / 13.59 11 190
Average= 3.40
(KJ/cycle)

Cycle 2 GMT 14/ 6/2023 8:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 9 14.89 413 55 0.06 / 5.81 8 11
2 3 1562.16 2 14.72 2514 74 0.13 / 5.89 9 13
3 7 1878.32 40 14.60 2826 1650 1.78 / 7.54 13 14
4 13 1196.56 20 14.67 2014 591 2.37 / 8.13 10 15
5 13 661.04 20 14.76 1291 381 2.75 / 8.51 10 15
6 13 82.72 20 14.94 409 122 2.87 / 8.63 10 15
7 8 -0.08 289 14.93 260 1122 4.00 / 9.76 10 182
Average= 3.25
(KJ/cycle)

Cycle 1 GMT 9/ 6/2023 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 18 15.10 386 105 0.10 / 1.69 8 12
2 3 1218.04 -4 15.33 0 0 0.00 / 1.69 8 12
3 7 1958.96 40 14.57 2911 1697 1.80 / 3.38 12 14
4 13 1405.04 20 14.61 2255 659 2.46 / 4.04 10 14
5 13 791.44 20 14.70 1468 432 2.89 / 4.47 10 15
6 13 199.92 20 14.88 578 172 3.06 / 4.65 10 15
7 13 81.68 20 14.91 389 116 3.18 / 4.76 10 14
8 8 0.12 272 14.91 246 998 4.18 / 5.76 11 159
Average= 2.88
(KJ/cycle)

Cycle 0 GMT 4/ 6/2023 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 140.84 18 15.23 464 127 0.13 / 0.13 10 13
2 7 154.24 41 15.21 473 295 0.42 / 0.42 13 13
3 13 153.68 20 15.19 465 141 0.56 / 0.56 11 13
4 13 90.32 20 15.19 364 111 0.67 / 0.67 11 13
5 8 0.08 272 15.17 220 908 1.58 / 1.58 10 185
Average= 1.58
(KJ/cycle)