SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 17 | 15.04 | 417 | 107 | 0.11 / 455.05 | 5 | 6 |
2 | 7 | 2012.56 | 40 | 14.66 | 3070 | 1800 | 1.91 / 456.85 | 6 | 15 |
3 | 13 | 1422.76 | 20 | 14.74 | 2259 | 666 | 2.57 / 457.51 | 5 | 20 |
4 | 13 | 751.92 | 20 | 14.87 | 1337 | 398 | 2.97 / 457.91 | 5 | 26 |
5 | 13 | 169.36 | 20 | 15.03 | 524 | 158 | 3.13 / 458.07 | 5 | 26 |
6 | 8 | 0.12 | 293 | 15.03 | 269 | 1185 | 4.31 / 459.25 | 5 | 135 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 17 | 15.04 | 405 | 104 | 0.10 / 450.78 | 5 | 6 |
2 | 7 | 2013.08 | 40 | 14.67 | 3071 | 1802 | 1.91 / 452.58 | 6 | 14 |
3 | 13 | 1347.76 | 20 | 14.75 | 2162 | 638 | 2.54 / 453.22 | 5 | 20 |
4 | 13 | 773.36 | 20 | 14.86 | 1376 | 409 | 2.95 / 453.63 | 5 | 26 |
5 | 13 | 81.24 | 20 | 15.06 | 397 | 120 | 3.07 / 453.75 | 5 | 22 |
6 | 8 | -0.04 | 293 | 15.03 | 270 | 1189 | 4.26 / 454.94 | 5 | 143 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 17 | 15.04 | 415 | 106 | 0.11 / 446.49 | 5 | 6 |
2 | 7 | 2014.48 | 40 | 14.67 | 3060 | 1796 | 1.90 / 448.28 | 6 | 13 |
3 | 13 | 1400.28 | 20 | 14.74 | 2229 | 657 | 2.56 / 448.94 | 5 | 19 |
4 | 13 | 762.64 | 20 | 14.87 | 1361 | 405 | 2.96 / 449.34 | 5 | 24 |
5 | 13 | 103.80 | 20 | 15.06 | 429 | 129 | 3.09 / 449.47 | 5 | 22 |
6 | 13 | 33.68 | 20 | 15.07 | 327 | 99 | 3.19 / 449.57 | 5 | 22 |
7 | 8 | 0.04 | 272 | 15.03 | 271 | 1108 | 4.30 / 450.68 | 5 | 129 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 17 | 15.03 | 401 | 102 | 0.10 / 442.22 | 5 | 6 |
2 | 7 | 2005.20 | 40 | 14.68 | 3046 | 1789 | 1.89 / 444.00 | 6 | 14 |
3 | 13 | 1380.64 | 20 | 14.75 | 2189 | 646 | 2.54 / 444.65 | 5 | 19 |
4 | 13 | 746.84 | 20 | 14.87 | 1341 | 399 | 2.94 / 445.05 | 5 | 25 |
5 | 13 | 95.00 | 20 | 15.06 | 417 | 126 | 3.06 / 445.17 | 5 | 24 |
6 | 13 | 28.60 | 20 | 15.07 | 322 | 97 | 3.16 / 445.27 | 5 | 23 |
7 | 8 | -0.08 | 272 | 15.03 | 271 | 1108 | 4.27 / 446.38 | 5 | 136 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 17 | 15.03 | 401 | 102 | 0.10 / 437.97 | 5 | 6 |
2 | 7 | 2007.88 | 41 | 14.67 | 3045 | 1831 | 1.93 / 439.80 | 6 | 14 |
3 | 13 | 1287.84 | 20 | 14.77 | 2074 | 613 | 2.55 / 440.42 | 5 | 21 |
4 | 13 | 693.68 | 20 | 14.89 | 1263 | 376 | 2.92 / 440.79 | 5 | 27 |
5 | 13 | 109.52 | 20 | 15.05 | 449 | 135 | 3.06 / 440.93 | 5 | 26 |
6 | 8 | -0.08 | 291 | 15.03 | 271 | 1185 | 4.24 / 442.11 | 5 | 134 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 17 | 15.03 | 419 | 107 | 0.11 / 433.63 | 5 | 6 |
2 | 7 | 2013.56 | 41 | 14.67 | 3054 | 1837 | 1.94 / 435.47 | 6 | 14 |
3 | 13 | 1422.88 | 20 | 14.74 | 2262 | 667 | 2.61 / 436.14 | 5 | 19 |
4 | 13 | 758.92 | 20 | 14.86 | 1352 | 402 | 3.01 / 436.54 | 5 | 26 |
5 | 13 | 127.44 | 20 | 15.04 | 472 | 142 | 3.15 / 436.68 | 5 | 27 |
6 | 8 | 0.00 | 291 | 15.03 | 272 | 1190 | 4.34 / 437.87 | 5 | 137 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 17 | 15.05 | 408 | 104 | 0.10 / 429.33 | 5 | 6 |
2 | 7 | 2008.92 | 40 | 14.67 | 3064 | 1798 | 1.90 / 431.13 | 6 | 14 |
3 | 13 | 1378.96 | 20 | 14.75 | 2211 | 652 | 2.55 / 431.78 | 5 | 20 |
4 | 13 | 703.24 | 20 | 14.88 | 1285 | 382 | 2.94 / 432.17 | 5 | 26 |
5 | 13 | 132.84 | 20 | 15.04 | 483 | 145 | 3.08 / 432.31 | 5 | 28 |
6 | 13 | 31.08 | 20 | 15.07 | 327 | 99 | 3.18 / 432.41 | 5 | 24 |
7 | 8 | -0.12 | 272 | 15.02 | 273 | 1115 | 4.30 / 433.53 | 5 | 134 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 17 | 15.04 | 411 | 105 | 0.11 / 425.09 | 5 | 6 |
2 | 7 | 2009.56 | 40 | 14.67 | 3058 | 1794 | 1.90 / 426.88 | 6 | 13 |
3 | 13 | 1375.80 | 20 | 14.75 | 2206 | 651 | 2.55 / 427.53 | 5 | 20 |
4 | 13 | 696.04 | 20 | 14.89 | 1270 | 378 | 2.93 / 427.91 | 5 | 25 |
5 | 13 | 83.32 | 20 | 15.07 | 408 | 123 | 3.05 / 428.03 | 5 | 23 |
6 | 13 | 28.44 | 20 | 15.08 | 326 | 98 | 3.15 / 428.13 | 5 | 24 |
7 | 8 | 0.12 | 270 | 15.03 | 271 | 1100 | 4.25 / 429.23 | 5 | 133 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 17 | 15.04 | 413 | 106 | 0.11 / 420.87 | 5 | 6 |
2 | 7 | 2012.08 | 40 | 14.67 | 3046 | 1787 | 1.89 / 422.66 | 6 | 14 |
3 | 13 | 1345.88 | 20 | 14.75 | 2173 | 641 | 2.53 / 423.30 | 5 | 20 |
4 | 13 | 674.72 | 20 | 14.89 | 1244 | 370 | 2.90 / 423.67 | 5 | 27 |
5 | 13 | 70.16 | 20 | 15.07 | 384 | 116 | 3.02 / 423.79 | 5 | 22 |
6 | 13 | 24.84 | 20 | 15.08 | 316 | 95 | 3.12 / 423.88 | 5 | 21 |
7 | 8 | 0.08 | 272 | 15.03 | 269 | 1100 | 4.22 / 424.98 | 5 | 133 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 17 | 15.04 | 402 | 103 | 0.10 / 416.58 | 5 | 6 |
2 | 7 | 2004.44 | 40 | 14.69 | 3038 | 1785 | 1.89 / 418.36 | 6 | 13 |
3 | 13 | 1411.32 | 20 | 14.75 | 2239 | 661 | 2.55 / 419.02 | 5 | 20 |
4 | 13 | 766.96 | 20 | 14.87 | 1366 | 406 | 2.95 / 419.43 | 5 | 26 |
5 | 13 | 108.16 | 20 | 15.06 | 442 | 133 | 3.09 / 419.56 | 5 | 24 |
6 | 13 | 39.64 | 20 | 15.07 | 336 | 101 | 3.19 / 419.66 | 5 | 24 |
7 | 8 | -0.12 | 272 | 15.04 | 269 | 1100 | 4.29 / 420.76 | 5 | 134 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 17 | 15.04 | 412 | 105 | 0.11 / 412.27 | 5 | 6 |
2 | 7 | 2005.20 | 40 | 14.68 | 3043 | 1787 | 1.89 / 414.06 | 6 | 14 |
3 | 13 | 1450.08 | 20 | 14.74 | 2307 | 680 | 2.57 / 414.74 | 5 | 20 |
4 | 13 | 785.24 | 20 | 14.87 | 1392 | 414 | 2.99 / 415.15 | 5 | 25 |
5 | 13 | 111.32 | 20 | 15.06 | 439 | 132 | 3.12 / 415.28 | 5 | 24 |
6 | 13 | 38.20 | 20 | 15.08 | 332 | 100 | 3.22 / 415.38 | 5 | 21 |
7 | 8 | 0.08 | 274 | 15.04 | 265 | 1092 | 4.31 / 416.48 | 5 | 141 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 17 | 15.05 | 398 | 102 | 0.10 / 408.02 | 5 | 6 |
2 | 7 | 2012.84 | 40 | 14.68 | 3056 | 1794 | 1.90 / 409.81 | 6 | 14 |
3 | 13 | 1399.00 | 20 | 14.75 | 2222 | 655 | 2.55 / 410.47 | 5 | 20 |
4 | 13 | 714.44 | 20 | 14.88 | 1293 | 385 | 2.94 / 410.85 | 5 | 25 |
5 | 13 | 90.48 | 20 | 15.07 | 407 | 123 | 3.06 / 410.98 | 5 | 23 |
6 | 13 | 34.76 | 20 | 15.08 | 330 | 100 | 3.16 / 411.08 | 5 | 20 |
7 | 8 | 0.04 | 272 | 15.04 | 266 | 1088 | 4.25 / 412.16 | 5 | 132 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 17 | 15.05 | 408 | 104 | 0.10 / 403.77 | 6 | 6 |
2 | 7 | 2011.28 | 40 | 14.67 | 3041 | 1784 | 1.89 / 405.55 | 6 | 14 |
3 | 13 | 1370.04 | 20 | 14.75 | 2186 | 645 | 2.53 / 406.20 | 5 | 20 |
4 | 13 | 760.48 | 20 | 14.87 | 1360 | 404 | 2.94 / 406.60 | 5 | 25 |
5 | 13 | 90.36 | 20 | 15.07 | 405 | 122 | 3.06 / 406.72 | 5 | 22 |
6 | 13 | 32.60 | 20 | 15.08 | 321 | 97 | 3.16 / 406.82 | 5 | 20 |
7 | 8 | -0.12 | 274 | 15.04 | 266 | 1096 | 4.25 / 407.92 | 5 | 143 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 17 | 15.06 | 382 | 98 | 0.10 / 399.52 | 6 | 6 |
2 | 7 | 2013.40 | 40 | 14.67 | 3057 | 1794 | 1.89 / 401.31 | 6 | 14 |
3 | 13 | 1301.52 | 20 | 14.77 | 2098 | 620 | 2.51 / 401.93 | 5 | 20 |
4 | 13 | 739.80 | 20 | 14.88 | 1322 | 393 | 2.90 / 402.32 | 5 | 24 |
5 | 13 | 153.44 | 20 | 15.06 | 496 | 149 | 3.05 / 402.47 | 5 | 21 |
6 | 13 | 44.12 | 20 | 15.08 | 332 | 100 | 3.15 / 402.57 | 5 | 19 |
7 | 8 | -0.04 | 276 | 15.04 | 263 | 1092 | 4.25 / 403.66 | 5 | 152 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.32 | 17 | 15.07 | 409 | 105 | 0.10 / 395.25 | 6 | 6 |
2 | 7 | 2009.88 | 40 | 14.67 | 3044 | 1786 | 1.89 / 397.04 | 6 | 13 |
3 | 13 | 1364.68 | 20 | 14.75 | 2192 | 647 | 2.54 / 397.69 | 5 | 20 |
4 | 13 | 734.76 | 20 | 14.88 | 1325 | 394 | 2.93 / 398.08 | 5 | 25 |
5 | 13 | 148.80 | 20 | 15.06 | 490 | 148 | 3.08 / 398.23 | 5 | 20 |
6 | 13 | 75.64 | 20 | 15.08 | 378 | 114 | 3.19 / 398.34 | 5 | 18 |
7 | 8 | 0.00 | 276 | 15.05 | 259 | 1076 | 4.27 / 399.42 | 5 | 139 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 17 | 15.07 | 384 | 98 | 0.10 / 390.96 | 6 | 6 |
2 | 7 | 2008.20 | 40 | 14.68 | 3043 | 1787 | 1.89 / 392.75 | 6 | 13 |
3 | 13 | 1373.08 | 20 | 14.76 | 2191 | 647 | 2.53 / 393.39 | 5 | 19 |
4 | 13 | 838.32 | 20 | 14.86 | 1465 | 435 | 2.97 / 393.83 | 5 | 24 |
5 | 13 | 198.32 | 20 | 15.05 | 556 | 167 | 3.13 / 394.00 | 5 | 19 |
6 | 13 | 53.88 | 20 | 15.09 | 337 | 102 | 3.24 / 394.10 | 5 | 15 |
7 | 8 | 0.08 | 276 | 15.06 | 253 | 1052 | 4.29 / 395.15 | 5 | 131 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 17 | 15.06 | 389 | 100 | 0.10 / 386.74 | 6 | 6 |
2 | 7 | 2011.16 | 40 | 14.68 | 3034 | 1782 | 1.88 / 388.52 | 6 | 13 |
3 | 13 | 1363.36 | 20 | 14.76 | 2181 | 644 | 2.52 / 389.17 | 5 | 19 |
4 | 13 | 768.52 | 20 | 14.88 | 1358 | 404 | 2.93 / 389.57 | 5 | 25 |
5 | 13 | 148.88 | 20 | 15.07 | 480 | 145 | 3.07 / 389.71 | 5 | 19 |
6 | 13 | 47.88 | 20 | 15.09 | 326 | 98 | 3.17 / 389.81 | 5 | 16 |
7 | 8 | 0.04 | 274 | 15.06 | 254 | 1048 | 4.22 / 390.86 | 5 | 133 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 17 | 15.08 | 380 | 97 | 0.10 / 382.44 | 6 | 6 |
2 | 7 | 2008.40 | 40 | 14.68 | 3057 | 1795 | 1.89 / 384.24 | 6 | 13 |
3 | 13 | 1406.04 | 20 | 14.75 | 2256 | 666 | 2.56 / 384.90 | 5 | 19 |
4 | 13 | 805.56 | 20 | 14.87 | 1422 | 423 | 2.98 / 385.32 | 5 | 24 |
5 | 13 | 162.56 | 20 | 15.06 | 508 | 153 | 3.13 / 385.48 | 5 | 21 |
6 | 13 | 56.76 | 20 | 15.09 | 345 | 104 | 3.24 / 385.58 | 5 | 17 |
7 | 8 | 0.04 | 276 | 15.06 | 255 | 1060 | 4.30 / 386.64 | 5 | 136 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.04 | 17 | 15.07 | 409 | 105 | 0.10 / 378.12 | 6 | 6 |
2 | 7 | 2011.12 | 41 | 14.68 | 3044 | 1832 | 1.94 / 379.95 | 6 | 14 |
3 | 13 | 1376.52 | 20 | 14.76 | 2216 | 654 | 2.59 / 380.61 | 5 | 20 |
4 | 13 | 800.48 | 20 | 14.88 | 1414 | 421 | 3.01 / 381.03 | 5 | 25 |
5 | 13 | 165.56 | 20 | 15.07 | 507 | 153 | 3.16 / 381.18 | 5 | 18 |
6 | 13 | 58.88 | 20 | 15.09 | 346 | 104 | 3.27 / 381.29 | 5 | 15 |
7 | 8 | 0.08 | 276 | 15.07 | 254 | 1056 | 4.33 / 382.34 | 5 | 143 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 17 | 15.07 | 402 | 103 | 0.10 / 373.86 | 6 | 6 |
2 | 7 | 2008.28 | 40 | 14.69 | 3041 | 1787 | 1.89 / 375.64 | 6 | 14 |
3 | 13 | 1405.32 | 20 | 14.76 | 2239 | 661 | 2.55 / 376.30 | 5 | 19 |
4 | 13 | 762.52 | 20 | 14.89 | 1351 | 402 | 2.95 / 376.71 | 5 | 25 |
5 | 13 | 182.72 | 20 | 15.07 | 524 | 158 | 3.11 / 376.86 | 5 | 19 |
6 | 13 | 72.60 | 20 | 15.09 | 361 | 109 | 3.22 / 376.97 | 5 | 16 |
7 | 8 | 0.00 | 276 | 15.07 | 251 | 1044 | 4.26 / 378.02 | 5 | 134 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 17 | 15.07 | 403 | 103 | 0.10 / 369.57 | 6 | 6 |
2 | 7 | 2008.56 | 40 | 14.69 | 3048 | 1791 | 1.89 / 371.36 | 6 | 13 |
3 | 13 | 1403.08 | 20 | 14.77 | 2231 | 659 | 2.55 / 372.02 | 5 | 19 |
4 | 13 | 800.92 | 20 | 14.89 | 1412 | 420 | 2.97 / 372.44 | 5 | 25 |
5 | 13 | 137.44 | 20 | 15.08 | 473 | 143 | 3.12 / 372.58 | 5 | 21 |
6 | 13 | 44.24 | 20 | 15.10 | 330 | 100 | 3.22 / 372.68 | 5 | 18 |
7 | 8 | 0.04 | 276 | 15.07 | 257 | 1069 | 4.29 / 373.75 | 5 | 141 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 17 | 15.07 | 404 | 104 | 0.10 / 365.32 | 6 | 6 |
2 | 7 | 2003.36 | 40 | 14.69 | 3050 | 1792 | 1.90 / 367.12 | 6 | 14 |
3 | 13 | 1336.56 | 20 | 14.78 | 2142 | 633 | 2.53 / 367.75 | 5 | 20 |
4 | 13 | 742.92 | 20 | 14.90 | 1321 | 394 | 2.92 / 368.14 | 5 | 25 |
5 | 13 | 108.52 | 20 | 15.08 | 437 | 132 | 3.05 / 368.28 | 5 | 23 |
6 | 13 | 37.32 | 20 | 15.10 | 327 | 99 | 3.15 / 368.37 | 5 | 22 |
7 | 8 | 0.00 | 274 | 15.06 | 265 | 1094 | 4.25 / 369.47 | 5 | 143 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 17 | 15.06 | 405 | 104 | 0.10 / 361.08 | 5 | 6 |
2 | 7 | 2013.32 | 40 | 14.69 | 3053 | 1794 | 1.90 / 362.87 | 6 | 14 |
3 | 13 | 1377.84 | 20 | 14.77 | 2210 | 653 | 2.55 / 363.52 | 5 | 20 |
4 | 13 | 689.36 | 20 | 14.92 | 1261 | 376 | 2.93 / 363.90 | 5 | 26 |
5 | 13 | 112.24 | 20 | 15.08 | 444 | 134 | 3.06 / 364.03 | 5 | 24 |
6 | 13 | 22.96 | 20 | 15.10 | 308 | 93 | 3.15 / 364.13 | 5 | 20 |
7 | 8 | -0.08 | 272 | 15.06 | 267 | 1094 | 4.25 / 365.22 | 5 | 136 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 17 | 15.06 | 405 | 104 | 0.10 / 356.84 | 5 | 6 |
2 | 7 | 2010.88 | 40 | 14.70 | 3053 | 1795 | 1.90 / 358.64 | 6 | 14 |
3 | 13 | 1308.40 | 20 | 14.80 | 2093 | 620 | 2.52 / 359.26 | 5 | 20 |
4 | 13 | 744.72 | 20 | 14.90 | 1330 | 396 | 2.91 / 359.65 | 5 | 26 |
5 | 13 | 111.12 | 20 | 15.08 | 443 | 134 | 3.05 / 359.79 | 5 | 25 |
6 | 13 | 16.52 | 20 | 15.11 | 300 | 91 | 3.14 / 359.88 | 5 | 22 |
7 | 8 | -0.04 | 272 | 15.06 | 268 | 1098 | 4.24 / 360.97 | 5 | 136 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 17 | 15.06 | 411 | 105 | 0.11 / 352.58 | 5 | 6 |
2 | 7 | 2014.20 | 40 | 14.69 | 3059 | 1797 | 1.90 / 354.37 | 6 | 13 |
3 | 13 | 1347.36 | 20 | 14.79 | 2155 | 637 | 2.54 / 355.01 | 5 | 20 |
4 | 13 | 728.28 | 20 | 14.91 | 1313 | 392 | 2.93 / 355.40 | 5 | 25 |
5 | 13 | 96.28 | 20 | 15.09 | 424 | 128 | 3.06 / 355.53 | 5 | 24 |
6 | 13 | 27.04 | 20 | 15.10 | 323 | 98 | 3.16 / 355.63 | 5 | 22 |
7 | 8 | -0.12 | 272 | 15.06 | 271 | 1110 | 4.27 / 356.74 | 5 | 137 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 17 | 15.08 | 406 | 104 | 0.10 / 348.28 | 6 | 6 |
2 | 7 | 2009.48 | 40 | 14.70 | 3041 | 1788 | 1.89 / 350.06 | 6 | 14 |
3 | 13 | 1390.92 | 20 | 14.78 | 2215 | 655 | 2.55 / 350.72 | 5 | 19 |
4 | 13 | 720.92 | 20 | 14.91 | 1303 | 389 | 2.94 / 351.11 | 5 | 26 |
5 | 13 | 102.72 | 20 | 15.09 | 431 | 130 | 3.07 / 351.24 | 5 | 24 |
6 | 13 | 30.24 | 20 | 15.10 | 326 | 98 | 3.16 / 351.34 | 5 | 23 |
7 | 8 | -0.12 | 274 | 15.06 | 275 | 1135 | 4.30 / 352.47 | 5 | 145 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 17 | 15.07 | 412 | 106 | 0.11 / 344.00 | 6 | 6 |
2 | 7 | 2014.08 | 40 | 14.71 | 3041 | 1789 | 1.89 / 345.79 | 6 | 13 |
3 | 13 | 1386.04 | 20 | 14.79 | 2213 | 655 | 2.55 / 346.44 | 5 | 19 |
4 | 13 | 773.32 | 20 | 14.90 | 1377 | 410 | 2.96 / 346.85 | 5 | 25 |
5 | 13 | 110.88 | 20 | 15.10 | 437 | 132 | 3.09 / 346.98 | 5 | 19 |
6 | 13 | 21.60 | 20 | 15.12 | 302 | 91 | 3.18 / 347.08 | 5 | 17 |
7 | 8 | 0.08 | 274 | 15.08 | 265 | 1095 | 4.28 / 348.17 | 5 | 134 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 17 | 15.08 | 406 | 104 | 0.10 / 339.69 | 5 | 6 |
2 | 7 | 2013.96 | 40 | 14.71 | 3050 | 1795 | 1.90 / 341.48 | 6 | 13 |
3 | 13 | 1378.28 | 20 | 14.79 | 2206 | 653 | 2.55 / 342.13 | 5 | 19 |
4 | 13 | 774.08 | 20 | 14.91 | 1378 | 411 | 2.96 / 342.55 | 5 | 24 |
5 | 13 | 107.32 | 20 | 15.10 | 436 | 132 | 3.09 / 342.68 | 5 | 21 |
6 | 13 | 34.84 | 20 | 15.11 | 334 | 101 | 3.19 / 342.78 | 5 | 21 |
7 | 8 | -0.08 | 274 | 15.07 | 270 | 1115 | 4.31 / 343.89 | 5 | 142 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 17 | 15.08 | 410 | 105 | 0.11 / 335.44 | 5 | 6 |
2 | 7 | 2013.16 | 40 | 14.70 | 3043 | 1789 | 1.89 / 337.22 | 6 | 13 |
3 | 13 | 1295.12 | 20 | 14.81 | 2101 | 622 | 2.52 / 337.85 | 5 | 19 |
4 | 13 | 767.40 | 20 | 14.91 | 1365 | 407 | 2.92 / 338.25 | 5 | 25 |
5 | 13 | 90.20 | 20 | 15.11 | 406 | 123 | 3.05 / 338.38 | 5 | 21 |
6 | 13 | 25.84 | 20 | 15.12 | 316 | 96 | 3.14 / 338.47 | 5 | 21 |
7 | 8 | -0.04 | 272 | 15.07 | 271 | 1111 | 4.25 / 339.58 | 5 | 135 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 17 | 15.08 | 408 | 105 | 0.10 / 331.16 | 5 | 6 |
2 | 7 | 2003.60 | 40 | 14.72 | 3032 | 1785 | 1.89 / 332.95 | 6 | 13 |
3 | 13 | 1366.80 | 20 | 14.80 | 2186 | 647 | 2.54 / 333.60 | 5 | 20 |
4 | 13 | 766.08 | 20 | 14.92 | 1362 | 406 | 2.94 / 334.00 | 5 | 25 |
5 | 13 | 104.08 | 20 | 15.11 | 424 | 128 | 3.07 / 334.13 | 5 | 21 |
6 | 13 | 33.12 | 20 | 15.12 | 318 | 96 | 3.17 / 334.23 | 5 | 20 |
7 | 8 | 0.00 | 272 | 15.08 | 269 | 1103 | 4.27 / 335.33 | 5 | 133 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 17 | 15.09 | 402 | 103 | 0.10 / 326.95 | 5 | 6 |
2 | 7 | 2014.00 | 40 | 14.71 | 3041 | 1789 | 1.89 / 328.74 | 6 | 13 |
3 | 13 | 1338.24 | 20 | 14.81 | 2126 | 630 | 2.52 / 329.37 | 5 | 19 |
4 | 13 | 729.32 | 20 | 14.93 | 1303 | 389 | 2.91 / 329.76 | 5 | 25 |
5 | 13 | 98.52 | 20 | 15.11 | 414 | 125 | 3.04 / 329.88 | 5 | 21 |
6 | 13 | 15.64 | 20 | 15.13 | 289 | 87 | 3.12 / 329.97 | 5 | 19 |
7 | 8 | -0.04 | 274 | 15.08 | 264 | 1091 | 4.21 / 331.06 | 5 | 135 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 17 | 15.09 | 397 | 102 | 0.10 / 322.69 | 5 | 6 |
2 | 7 | 2012.08 | 40 | 14.72 | 3045 | 1793 | 1.89 / 324.48 | 6 | 13 |
3 | 13 | 1372.72 | 20 | 14.81 | 2188 | 648 | 2.54 / 325.13 | 5 | 19 |
4 | 13 | 765.84 | 20 | 14.92 | 1361 | 406 | 2.95 / 325.54 | 5 | 25 |
5 | 13 | 130.64 | 20 | 15.10 | 465 | 140 | 3.09 / 325.68 | 5 | 21 |
6 | 13 | 27.20 | 20 | 15.13 | 307 | 93 | 3.18 / 325.77 | 5 | 18 |
7 | 8 | 0.04 | 272 | 15.08 | 262 | 1075 | 4.26 / 326.84 | 5 | 142 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 17 | 15.08 | 405 | 104 | 0.10 / 318.38 | 5 | 6 |
2 | 7 | 2011.28 | 40 | 14.72 | 3056 | 1799 | 1.90 / 320.18 | 6 | 13 |
3 | 13 | 1455.56 | 20 | 14.79 | 2293 | 678 | 2.58 / 320.85 | 5 | 18 |
4 | 13 | 795.80 | 20 | 14.91 | 1405 | 419 | 3.00 / 321.27 | 5 | 25 |
5 | 13 | 125.04 | 20 | 15.11 | 456 | 138 | 3.14 / 321.41 | 5 | 21 |
6 | 13 | 26.24 | 20 | 15.13 | 309 | 94 | 3.23 / 321.50 | 5 | 19 |
7 | 8 | 0.00 | 274 | 15.09 | 262 | 1083 | 4.32 / 322.59 | 5 | 131 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 17 | 15.10 | 407 | 104 | 0.10 / 314.01 | 5 | 6 |
2 | 7 | 2005.60 | 40 | 14.72 | 3049 | 1795 | 1.90 / 315.81 | 6 | 13 |
3 | 13 | 1423.68 | 20 | 14.80 | 2258 | 668 | 2.57 / 316.48 | 5 | 19 |
4 | 13 | 835.16 | 20 | 14.90 | 1465 | 437 | 3.00 / 316.91 | 5 | 24 |
5 | 13 | 152.36 | 20 | 15.10 | 503 | 152 | 3.16 / 317.07 | 5 | 21 |
6 | 13 | 35.92 | 20 | 15.13 | 328 | 99 | 3.26 / 317.16 | 5 | 19 |
7 | 8 | -0.04 | 274 | 15.09 | 268 | 1108 | 4.36 / 318.27 | 5 | 132 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 17 | 15.10 | 414 | 106 | 0.11 / 309.73 | 5 | 6 |
2 | 7 | 2011.40 | 40 | 14.72 | 3044 | 1792 | 1.90 / 311.52 | 6 | 13 |
3 | 13 | 1379.60 | 20 | 14.81 | 2202 | 652 | 2.55 / 312.17 | 5 | 20 |
4 | 13 | 772.80 | 20 | 14.93 | 1371 | 409 | 2.96 / 312.58 | 5 | 25 |
5 | 13 | 140.56 | 20 | 15.11 | 478 | 144 | 3.10 / 312.73 | 5 | 20 |
6 | 13 | 28.64 | 20 | 15.14 | 315 | 95 | 3.20 / 312.82 | 5 | 18 |
7 | 8 | -0.08 | 272 | 15.09 | 265 | 1088 | 4.29 / 313.91 | 5 | 130 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 17 | 15.10 | 403 | 103 | 0.10 / 305.43 | 5 | 6 |
2 | 7 | 2007.28 | 40 | 14.72 | 3038 | 1789 | 1.89 / 307.22 | 6 | 13 |
3 | 13 | 1327.88 | 20 | 14.83 | 2137 | 634 | 2.53 / 307.85 | 5 | 20 |
4 | 13 | 798.00 | 20 | 14.92 | 1416 | 423 | 2.95 / 308.28 | 5 | 25 |
5 | 13 | 151.80 | 20 | 15.11 | 499 | 151 | 3.10 / 308.43 | 5 | 21 |
6 | 13 | 17.56 | 20 | 15.15 | 294 | 89 | 3.19 / 308.52 | 5 | 17 |
7 | 8 | 0.00 | 274 | 15.10 | 267 | 1105 | 4.29 / 309.62 | 5 | 144 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 17 | 15.09 | 406 | 104 | 0.10 / 301.20 | 5 | 6 |
2 | 7 | 2007.64 | 40 | 14.72 | 3044 | 1792 | 1.90 / 303.00 | 6 | 13 |
3 | 13 | 1329.96 | 20 | 14.83 | 2116 | 628 | 2.52 / 303.62 | 5 | 20 |
4 | 13 | 758.40 | 20 | 14.94 | 1349 | 403 | 2.93 / 304.03 | 5 | 25 |
5 | 13 | 96.84 | 20 | 15.13 | 412 | 125 | 3.05 / 304.15 | 5 | 19 |
6 | 8 | 0.04 | 293 | 15.10 | 266 | 1177 | 4.23 / 305.33 | 5 | 144 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 17 | 15.10 | 411 | 106 | 0.11 / 296.90 | 5 | 6 |
2 | 7 | 2013.72 | 40 | 14.73 | 3050 | 1797 | 1.90 / 298.70 | 6 | 13 |
3 | 13 | 1390.28 | 20 | 14.82 | 2210 | 655 | 2.56 / 299.36 | 5 | 19 |
4 | 13 | 748.24 | 20 | 14.94 | 1338 | 400 | 2.96 / 299.76 | 5 | 25 |
5 | 13 | 116.80 | 20 | 15.12 | 450 | 136 | 3.09 / 299.89 | 5 | 21 |
6 | 8 | 0.00 | 293 | 15.10 | 273 | 1208 | 4.30 / 301.10 | 5 | 148 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 17 | 15.12 | 413 | 106 | 0.11 / 292.57 | 5 | 6 |
2 | 7 | 2006.88 | 40 | 14.73 | 3048 | 1796 | 1.90 / 294.37 | 6 | 13 |
3 | 13 | 1408.20 | 20 | 14.81 | 2241 | 664 | 2.57 / 295.03 | 5 | 19 |
4 | 13 | 826.40 | 20 | 14.92 | 1451 | 433 | 3.00 / 295.46 | 5 | 25 |
5 | 13 | 147.28 | 20 | 15.12 | 488 | 148 | 3.15 / 295.61 | 5 | 21 |
6 | 8 | -0.04 | 293 | 15.11 | 268 | 1186 | 4.33 / 296.80 | 5 | 134 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 17 | 15.12 | 408 | 105 | 0.10 / 288.26 | 5 | 6 |
2 | 7 | 2015.08 | 41 | 14.72 | 3059 | 1846 | 1.95 / 290.11 | 6 | 13 |
3 | 13 | 1366.24 | 20 | 14.83 | 2184 | 648 | 2.60 / 290.75 | 5 | 20 |
4 | 13 | 727.80 | 20 | 14.96 | 1313 | 393 | 2.99 / 291.15 | 5 | 24 |
5 | 13 | 180.60 | 20 | 15.12 | 528 | 160 | 3.15 / 291.31 | 5 | 18 |
6 | 8 | 0.08 | 295 | 15.12 | 260 | 1160 | 4.31 / 292.47 | 5 | 150 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 17 | 15.11 | 405 | 104 | 0.10 / 283.97 | 5 | 6 |
2 | 7 | 2010.84 | 40 | 14.73 | 3058 | 1802 | 1.91 / 285.77 | 6 | 13 |
3 | 13 | 1395.00 | 20 | 14.83 | 2224 | 660 | 2.57 / 286.43 | 5 | 19 |
4 | 13 | 753.88 | 20 | 14.95 | 1345 | 402 | 2.97 / 286.83 | 5 | 25 |
5 | 13 | 169.16 | 20 | 15.12 | 518 | 157 | 3.12 / 286.99 | 5 | 20 |
6 | 8 | 0.12 | 293 | 15.12 | 263 | 1165 | 4.29 / 288.15 | 5 | 137 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 17 | 15.11 | 414 | 106 | 0.11 / 279.68 | 5 | 6 |
2 | 7 | 2012.80 | 41 | 14.73 | 3049 | 1841 | 1.95 / 281.52 | 6 | 13 |
3 | 13 | 1338.28 | 20 | 14.84 | 2154 | 639 | 2.59 / 282.16 | 5 | 20 |
4 | 13 | 699.88 | 20 | 14.97 | 1276 | 382 | 2.97 / 282.54 | 5 | 25 |
5 | 13 | 119.40 | 20 | 15.14 | 444 | 134 | 3.10 / 282.67 | 5 | 20 |
6 | 8 | 0.00 | 293 | 15.11 | 269 | 1191 | 4.29 / 283.86 | 5 | 144 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 17 | 15.11 | 412 | 106 | 0.11 / 275.36 | 5 | 6 |
2 | 7 | 2012.16 | 41 | 14.74 | 3047 | 1841 | 1.95 / 277.21 | 6 | 13 |
3 | 13 | 1331.96 | 20 | 14.84 | 2144 | 636 | 2.58 / 277.84 | 5 | 20 |
4 | 13 | 696.44 | 20 | 14.98 | 1269 | 380 | 2.96 / 278.22 | 5 | 25 |
5 | 13 | 182.52 | 20 | 15.12 | 546 | 165 | 3.13 / 278.39 | 5 | 24 |
6 | 8 | 0.56 | 291 | 15.11 | 269 | 1183 | 4.31 / 279.57 | 5 | 137 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 17 | 15.13 | 409 | 105 | 0.11 / 271.04 | 5 | 6 |
2 | 7 | 2007.28 | 41 | 14.74 | 3051 | 1844 | 1.95 / 272.88 | 6 | 13 |
3 | 13 | 1354.60 | 20 | 14.84 | 2173 | 645 | 2.59 / 273.53 | 5 | 20 |
4 | 13 | 749.24 | 20 | 14.96 | 1345 | 402 | 3.00 / 273.93 | 5 | 24 |
5 | 13 | 106.28 | 20 | 15.14 | 433 | 131 | 3.13 / 274.06 | 5 | 20 |
6 | 8 | -0.04 | 291 | 15.12 | 272 | 1197 | 4.32 / 275.26 | 5 | 133 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 17 | 15.13 | 412 | 106 | 0.11 / 266.74 | 5 | 6 |
2 | 7 | 2003.92 | 40 | 14.74 | 3042 | 1794 | 1.90 / 268.53 | 6 | 13 |
3 | 13 | 1421.12 | 20 | 14.83 | 2255 | 669 | 2.57 / 269.20 | 5 | 19 |
4 | 13 | 757.04 | 20 | 14.97 | 1352 | 405 | 2.97 / 269.60 | 5 | 24 |
5 | 13 | 203.40 | 20 | 15.13 | 564 | 171 | 3.14 / 269.77 | 5 | 19 |
6 | 8 | 0.16 | 293 | 15.13 | 262 | 1161 | 4.31 / 270.93 | 5 | 142 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 17 | 15.13 | 416 | 107 | 0.11 / 262.48 | 5 | 6 |
2 | 7 | 2006.76 | 40 | 14.74 | 3028 | 1785 | 1.89 / 264.27 | 6 | 13 |
3 | 13 | 1354.96 | 20 | 14.85 | 2172 | 645 | 2.54 / 264.92 | 5 | 19 |
4 | 13 | 776.64 | 20 | 14.96 | 1372 | 411 | 2.95 / 265.33 | 5 | 24 |
5 | 13 | 176.96 | 20 | 15.14 | 525 | 159 | 3.11 / 265.48 | 5 | 17 |
6 | 8 | 0.08 | 293 | 15.14 | 258 | 1144 | 4.25 / 266.63 | 5 | 142 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 17 | 15.13 | 403 | 104 | 0.10 / 258.23 | 5 | 6 |
2 | 7 | 2007.16 | 40 | 14.75 | 3037 | 1792 | 1.90 / 260.02 | 6 | 13 |
3 | 13 | 1298.68 | 20 | 14.87 | 2091 | 622 | 2.52 / 260.64 | 5 | 20 |
4 | 13 | 773.60 | 20 | 14.97 | 1373 | 411 | 2.93 / 261.05 | 5 | 25 |
5 | 13 | 176.76 | 20 | 15.14 | 521 | 158 | 3.09 / 261.21 | 5 | 19 |
6 | 8 | 0.20 | 295 | 15.14 | 261 | 1166 | 4.25 / 262.38 | 5 | 155 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 17 | 15.12 | 413 | 106 | 0.11 / 253.94 | 5 | 6 |
2 | 7 | 2015.36 | 41 | 14.75 | 3044 | 1841 | 1.95 / 255.78 | 6 | 13 |
3 | 13 | 1299.32 | 20 | 14.87 | 2084 | 620 | 2.57 / 256.40 | 5 | 20 |
4 | 13 | 771.84 | 20 | 14.97 | 1366 | 409 | 2.98 / 256.81 | 5 | 25 |
5 | 13 | 103.76 | 20 | 15.16 | 424 | 129 | 3.10 / 256.94 | 5 | 20 |
6 | 8 | 0.24 | 291 | 15.13 | 270 | 1189 | 4.29 / 258.13 | 5 | 134 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 17 | 15.13 | 399 | 103 | 0.10 / 249.69 | 5 | 6 |
2 | 7 | 2011.20 | 40 | 14.75 | 3035 | 1791 | 1.89 / 251.48 | 6 | 13 |
3 | 13 | 1323.40 | 20 | 14.86 | 2126 | 632 | 2.53 / 252.11 | 5 | 20 |
4 | 13 | 769.72 | 20 | 14.97 | 1366 | 409 | 2.93 / 252.52 | 5 | 25 |
5 | 13 | 84.20 | 20 | 15.16 | 400 | 121 | 3.06 / 252.64 | 5 | 23 |
6 | 8 | 0.00 | 291 | 15.13 | 271 | 1193 | 4.25 / 253.83 | 5 | 139 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 17 | 15.13 | 408 | 105 | 0.10 / 245.48 | 5 | 6 |
2 | 7 | 2008.12 | 40 | 14.76 | 3028 | 1788 | 1.89 / 247.27 | 6 | 13 |
3 | 13 | 1365.88 | 20 | 14.86 | 2175 | 646 | 2.54 / 247.92 | 5 | 19 |
4 | 13 | 680.64 | 20 | 15.00 | 1239 | 372 | 2.91 / 248.29 | 5 | 25 |
5 | 13 | 92.24 | 20 | 15.17 | 399 | 121 | 3.03 / 248.41 | 5 | 20 |
6 | 8 | 0.08 | 293 | 15.14 | 265 | 1176 | 4.21 / 249.58 | 5 | 144 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 17 | 15.13 | 409 | 105 | 0.11 / 241.20 | 5 | 6 |
2 | 7 | 2013.12 | 40 | 14.75 | 3051 | 1800 | 1.91 / 243.00 | 6 | 13 |
3 | 13 | 1339.16 | 20 | 14.87 | 2132 | 634 | 2.54 / 243.63 | 5 | 20 |
4 | 13 | 802.32 | 20 | 14.96 | 1418 | 424 | 2.96 / 244.06 | 5 | 25 |
5 | 13 | 86.96 | 20 | 15.17 | 405 | 123 | 3.09 / 244.18 | 5 | 20 |
6 | 8 | -0.04 | 293 | 15.14 | 270 | 1198 | 4.28 / 245.38 | 5 | 147 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 17 | 15.14 | 402 | 103 | 0.10 / 236.91 | 5 | 6 |
2 | 7 | 2009.60 | 40 | 14.76 | 3036 | 1792 | 1.90 / 238.70 | 6 | 13 |
3 | 13 | 1457.84 | 20 | 14.85 | 2298 | 683 | 2.58 / 239.38 | 5 | 19 |
4 | 13 | 725.68 | 20 | 14.99 | 1305 | 391 | 2.97 / 239.77 | 5 | 25 |
5 | 13 | 112.60 | 20 | 15.16 | 436 | 132 | 3.10 / 239.90 | 5 | 21 |
6 | 8 | 0.16 | 293 | 15.14 | 268 | 1189 | 4.29 / 241.09 | 5 | 142 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 17 | 15.14 | 407 | 105 | 0.10 / 232.62 | 5 | 6 |
2 | 7 | 2005.08 | 40 | 14.76 | 3038 | 1794 | 1.90 / 234.42 | 6 | 13 |
3 | 13 | 1408.56 | 20 | 14.86 | 2237 | 665 | 2.56 / 235.08 | 5 | 19 |
4 | 13 | 761.12 | 20 | 14.98 | 1356 | 406 | 2.97 / 235.49 | 5 | 25 |
5 | 13 | 147.80 | 20 | 15.16 | 484 | 147 | 3.12 / 235.63 | 5 | 21 |
6 | 8 | -0.04 | 293 | 15.15 | 263 | 1167 | 4.28 / 236.80 | 5 | 132 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 17 | 15.14 | 410 | 106 | 0.11 / 228.30 | 5 | 6 |
2 | 7 | 2008.52 | 40 | 14.76 | 3043 | 1797 | 1.90 / 230.09 | 6 | 13 |
3 | 13 | 1424.16 | 20 | 14.86 | 2248 | 668 | 2.57 / 230.76 | 5 | 19 |
4 | 13 | 764.52 | 20 | 14.99 | 1357 | 407 | 2.98 / 231.17 | 5 | 25 |
5 | 13 | 174.32 | 20 | 15.15 | 525 | 159 | 3.14 / 231.33 | 5 | 22 |
6 | 13 | 17.32 | 20 | 15.19 | 297 | 90 | 3.23 / 231.42 | 5 | 19 |
7 | 8 | 0.00 | 272 | 15.14 | 267 | 1100 | 4.33 / 232.52 | 5 | 136 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 17 | 15.14 | 410 | 106 | 0.11 / 224.02 | 5 | 6 |
2 | 7 | 2004.56 | 41 | 14.76 | 3036 | 1837 | 1.94 / 225.85 | 6 | 13 |
3 | 13 | 1352.64 | 20 | 14.88 | 2158 | 642 | 2.59 / 226.49 | 5 | 20 |
4 | 13 | 714.60 | 20 | 15.00 | 1290 | 387 | 2.97 / 226.88 | 5 | 26 |
5 | 13 | 80.88 | 20 | 15.18 | 396 | 120 | 3.09 / 227.00 | 5 | 21 |
6 | 8 | -0.04 | 291 | 15.15 | 270 | 1190 | 4.28 / 228.19 | 5 | 141 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 17 | 15.15 | 408 | 105 | 0.11 / 219.74 | 5 | 6 |
2 | 7 | 2009.12 | 41 | 14.76 | 3050 | 1846 | 1.95 / 221.59 | 6 | 13 |
3 | 13 | 1321.32 | 20 | 14.88 | 2115 | 629 | 2.58 / 222.22 | 5 | 20 |
4 | 13 | 703.60 | 20 | 15.01 | 1272 | 382 | 2.96 / 222.60 | 5 | 25 |
5 | 13 | 70.64 | 20 | 15.18 | 379 | 115 | 3.08 / 222.72 | 5 | 22 |
6 | 8 | 0.12 | 291 | 15.14 | 271 | 1194 | 4.27 / 223.91 | 5 | 146 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 17 | 15.16 | 400 | 103 | 0.10 / 215.48 | 5 | 6 |
2 | 7 | 2011.24 | 40 | 14.76 | 3048 | 1800 | 1.90 / 217.28 | 6 | 13 |
3 | 13 | 1363.44 | 20 | 14.87 | 2177 | 647 | 2.55 / 217.93 | 5 | 20 |
4 | 13 | 756.76 | 20 | 14.99 | 1355 | 406 | 2.96 / 218.34 | 5 | 25 |
5 | 13 | 122.44 | 20 | 15.17 | 449 | 136 | 3.09 / 218.47 | 5 | 20 |
6 | 8 | 0.08 | 293 | 15.15 | 263 | 1167 | 4.26 / 219.64 | 5 | 139 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 17 | 15.15 | 404 | 104 | 0.10 / 211.26 | 5 | 6 |
2 | 7 | 2007.60 | 40 | 14.76 | 3036 | 1792 | 1.90 / 213.05 | 6 | 13 |
3 | 13 | 1333.56 | 20 | 14.88 | 2144 | 638 | 2.53 / 213.69 | 5 | 19 |
4 | 13 | 732.28 | 20 | 15.01 | 1316 | 395 | 2.93 / 214.08 | 5 | 24 |
5 | 13 | 145.80 | 20 | 15.18 | 476 | 145 | 3.07 / 214.23 | 5 | 16 |
6 | 13 | 18.08 | 20 | 15.21 | 286 | 87 | 3.16 / 214.32 | 5 | 14 |
7 | 8 | 0.12 | 274 | 15.16 | 256 | 1063 | 4.22 / 215.38 | 5 | 139 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 17 | 15.16 | 410 | 106 | 0.11 / 207.00 | 5 | 6 |
2 | 7 | 2003.36 | 40 | 14.77 | 3041 | 1797 | 1.90 / 208.80 | 6 | 13 |
3 | 13 | 1383.76 | 20 | 14.87 | 2190 | 651 | 2.55 / 209.45 | 5 | 19 |
4 | 13 | 710.20 | 20 | 15.01 | 1283 | 385 | 2.94 / 209.84 | 5 | 25 |
5 | 13 | 169.40 | 20 | 15.16 | 521 | 158 | 3.10 / 209.99 | 5 | 21 |
6 | 8 | 0.00 | 293 | 15.16 | 261 | 1159 | 4.26 / 211.15 | 5 | 140 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 17 | 15.17 | 408 | 105 | 0.11 / 202.72 | 6 | 6 |
2 | 7 | 2013.72 | 40 | 14.76 | 3051 | 1801 | 1.91 / 204.52 | 6 | 13 |
3 | 13 | 1377.16 | 20 | 14.87 | 2195 | 653 | 2.56 / 205.17 | 5 | 19 |
4 | 13 | 763.56 | 20 | 15.00 | 1358 | 407 | 2.97 / 205.58 | 5 | 24 |
5 | 13 | 165.36 | 20 | 15.17 | 507 | 154 | 3.12 / 205.74 | 5 | 18 |
6 | 13 | 23.68 | 20 | 15.20 | 300 | 91 | 3.21 / 205.83 | 5 | 15 |
7 | 8 | 0.08 | 274 | 15.16 | 258 | 1072 | 4.28 / 206.90 | 5 | 137 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 17 | 15.16 | 394 | 102 | 0.10 / 198.46 | 5 | 6 |
2 | 7 | 2010.80 | 40 | 14.77 | 3047 | 1800 | 1.90 / 200.26 | 6 | 13 |
3 | 13 | 1373.56 | 20 | 14.88 | 2184 | 650 | 2.55 / 200.91 | 5 | 19 |
4 | 13 | 771.16 | 20 | 15.00 | 1364 | 409 | 2.96 / 201.32 | 5 | 24 |
5 | 13 | 180.32 | 20 | 15.17 | 525 | 159 | 3.12 / 201.48 | 5 | 16 |
6 | 8 | 0.36 | 295 | 15.17 | 254 | 1137 | 4.26 / 202.61 | 5 | 140 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 17 | 15.17 | 400 | 103 | 0.10 / 194.23 | 5 | 6 |
2 | 7 | 2010.48 | 40 | 14.77 | 3039 | 1795 | 1.90 / 196.02 | 6 | 13 |
3 | 13 | 1373.88 | 20 | 14.88 | 2184 | 650 | 2.55 / 196.67 | 5 | 19 |
4 | 13 | 698.32 | 20 | 15.03 | 1259 | 378 | 2.93 / 197.05 | 5 | 24 |
5 | 13 | 193.60 | 20 | 15.17 | 540 | 164 | 3.09 / 197.21 | 5 | 17 |
6 | 13 | 45.76 | 20 | 15.21 | 320 | 97 | 3.19 / 197.31 | 5 | 14 |
7 | 8 | 0.12 | 274 | 15.17 | 252 | 1047 | 4.24 / 198.36 | 5 | 146 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 17 | 15.18 | 404 | 104 | 0.10 / 189.96 | 5 | 6 |
2 | 7 | 2009.20 | 40 | 14.77 | 3044 | 1798 | 1.90 / 191.75 | 6 | 13 |
3 | 13 | 1360.44 | 20 | 14.89 | 2166 | 645 | 2.55 / 192.40 | 5 | 19 |
4 | 13 | 831.00 | 20 | 14.99 | 1452 | 435 | 2.98 / 192.83 | 5 | 24 |
5 | 13 | 192.32 | 20 | 15.17 | 540 | 164 | 3.15 / 193.00 | 5 | 17 |
6 | 8 | 0.20 | 295 | 15.18 | 251 | 1124 | 4.27 / 194.12 | 5 | 149 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 17 | 15.18 | 407 | 105 | 0.11 / 185.72 | 5 | 6 |
2 | 7 | 2004.64 | 40 | 14.79 | 3029 | 1792 | 1.90 / 187.51 | 6 | 13 |
3 | 13 | 1409.76 | 20 | 14.87 | 2242 | 667 | 2.56 / 188.18 | 5 | 19 |
4 | 13 | 739.48 | 20 | 15.02 | 1320 | 397 | 2.96 / 188.58 | 5 | 24 |
5 | 13 | 172.48 | 20 | 15.18 | 507 | 154 | 3.11 / 188.73 | 5 | 16 |
6 | 13 | 15.36 | 20 | 15.22 | 275 | 84 | 3.20 / 188.82 | 5 | 12 |
7 | 8 | 0.00 | 274 | 15.18 | 249 | 1036 | 4.23 / 189.85 | 5 | 130 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 17 | 15.18 | 404 | 104 | 0.10 / 181.48 | 5 | 6 |
2 | 7 | 2003.88 | 40 | 14.78 | 3034 | 1794 | 1.90 / 183.27 | 6 | 13 |
3 | 13 | 1376.16 | 20 | 14.89 | 2181 | 650 | 2.55 / 183.92 | 5 | 19 |
4 | 13 | 809.80 | 20 | 15.00 | 1405 | 421 | 2.97 / 184.34 | 5 | 24 |
5 | 13 | 182.28 | 20 | 15.18 | 517 | 157 | 3.13 / 184.50 | 5 | 16 |
6 | 8 | 0.08 | 295 | 15.19 | 250 | 1120 | 4.25 / 185.62 | 5 | 138 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 17 | 15.18 | 403 | 104 | 0.10 / 177.25 | 5 | 6 |
2 | 7 | 2011.52 | 40 | 14.78 | 3043 | 1799 | 1.90 / 179.05 | 6 | 13 |
3 | 13 | 1372.64 | 20 | 14.89 | 2176 | 648 | 2.55 / 179.69 | 5 | 19 |
4 | 13 | 727.68 | 20 | 15.03 | 1298 | 390 | 2.94 / 180.08 | 5 | 24 |
5 | 13 | 182.60 | 20 | 15.18 | 521 | 158 | 3.10 / 180.24 | 5 | 16 |
6 | 8 | 0.16 | 295 | 15.19 | 252 | 1129 | 4.23 / 181.37 | 5 | 143 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 16 | 15.19 | 403 | 98 | 0.10 / 173.00 | 5 | 6 |
2 | 7 | 2003.28 | 40 | 14.79 | 3032 | 1794 | 1.89 / 174.80 | 6 | 13 |
3 | 13 | 1341.68 | 20 | 14.90 | 2147 | 640 | 2.53 / 175.44 | 5 | 19 |
4 | 13 | 749.48 | 20 | 15.02 | 1334 | 401 | 2.93 / 175.84 | 5 | 24 |
5 | 13 | 204.92 | 20 | 15.18 | 553 | 168 | 3.10 / 176.01 | 5 | 16 |
6 | 8 | 0.00 | 297 | 15.19 | 252 | 1137 | 4.24 / 177.14 | 5 | 149 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 16 | 15.19 | 391 | 95 | 0.10 / 168.74 | 5 | 6 |
2 | 7 | 2003.56 | 41 | 14.78 | 3024 | 1832 | 1.93 / 170.57 | 6 | 13 |
3 | 13 | 1355.84 | 20 | 14.90 | 2165 | 645 | 2.57 / 171.22 | 5 | 19 |
4 | 13 | 749.16 | 20 | 15.02 | 1335 | 401 | 2.97 / 171.62 | 5 | 23 |
5 | 13 | 184.28 | 20 | 15.19 | 527 | 160 | 3.13 / 171.78 | 5 | 16 |
6 | 8 | 0.12 | 295 | 15.19 | 252 | 1129 | 4.26 / 172.91 | 5 | 151 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 16 | 15.19 | 384 | 93 | 0.09 / 164.44 | 5 | 6 |
2 | 7 | 2003.64 | 40 | 14.79 | 3033 | 1794 | 1.89 / 166.23 | 6 | 13 |
3 | 13 | 1363.84 | 20 | 14.90 | 2171 | 647 | 2.53 / 166.88 | 5 | 19 |
4 | 13 | 803.84 | 20 | 15.01 | 1405 | 422 | 2.96 / 167.30 | 5 | 24 |
5 | 13 | 207.52 | 20 | 15.18 | 560 | 170 | 3.13 / 167.47 | 5 | 17 |
6 | 13 | 67.84 | 20 | 15.22 | 356 | 108 | 3.23 / 167.58 | 5 | 13 |
7 | 8 | 0.08 | 276 | 15.19 | 254 | 1065 | 4.30 / 168.64 | 5 | 141 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 16 | 15.19 | 393 | 96 | 0.10 / 160.11 | 5 | 6 |
2 | 7 | 2009.88 | 41 | 14.79 | 3041 | 1844 | 1.94 / 161.96 | 6 | 13 |
3 | 13 | 1475.76 | 20 | 14.87 | 2319 | 690 | 2.63 / 162.65 | 5 | 18 |
4 | 13 | 715.96 | 20 | 15.04 | 1282 | 386 | 3.01 / 163.03 | 5 | 23 |
5 | 13 | 178.24 | 20 | 15.20 | 517 | 157 | 3.17 / 163.19 | 5 | 16 |
6 | 13 | 71.64 | 20 | 15.22 | 359 | 109 | 3.28 / 163.30 | 5 | 13 |
7 | 8 | 0.20 | 274 | 15.19 | 251 | 1045 | 4.33 / 164.34 | 5 | 137 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 16 | 15.19 | 407 | 99 | 0.10 / 155.78 | 6 | 6 |
2 | 7 | 2007.64 | 40 | 14.80 | 3041 | 1800 | 1.90 / 157.59 | 6 | 13 |
3 | 13 | 1410.64 | 20 | 14.89 | 2242 | 668 | 2.57 / 158.25 | 5 | 19 |
4 | 13 | 797.08 | 20 | 15.02 | 1399 | 420 | 2.99 / 158.67 | 5 | 24 |
5 | 13 | 205.64 | 20 | 15.19 | 558 | 170 | 3.16 / 158.84 | 5 | 17 |
6 | 13 | 94.48 | 20 | 15.21 | 392 | 119 | 3.28 / 158.96 | 5 | 14 |
7 | 8 | 0.12 | 278 | 15.19 | 250 | 1056 | 4.33 / 160.02 | 5 | 151 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 16 | 15.20 | 383 | 93 | 0.09 / 151.46 | 6 | 6 |
2 | 7 | 2009.20 | 40 | 14.80 | 3033 | 1796 | 1.89 / 153.26 | 6 | 13 |
3 | 13 | 1437.36 | 20 | 14.89 | 2276 | 678 | 2.57 / 153.94 | 5 | 18 |
4 | 13 | 785.64 | 20 | 15.02 | 1382 | 415 | 2.98 / 154.35 | 5 | 23 |
5 | 13 | 198.04 | 20 | 15.20 | 543 | 165 | 3.15 / 154.52 | 5 | 16 |
6 | 13 | 89.84 | 20 | 15.22 | 383 | 117 | 3.26 / 154.63 | 5 | 13 |
7 | 8 | -0.04 | 278 | 15.20 | 249 | 1052 | 4.32 / 155.69 | 5 | 147 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 16 | 15.20 | 377 | 92 | 0.09 / 147.21 | 5 | 6 |
2 | 7 | 2008.72 | 40 | 14.80 | 3035 | 1797 | 1.89 / 149.00 | 6 | 13 |
3 | 13 | 1320.92 | 20 | 14.91 | 2128 | 635 | 2.52 / 149.64 | 5 | 19 |
4 | 13 | 762.96 | 20 | 15.04 | 1345 | 405 | 2.93 / 150.04 | 5 | 23 |
5 | 13 | 197.72 | 20 | 15.19 | 545 | 166 | 3.09 / 150.21 | 5 | 17 |
6 | 13 | 88.76 | 20 | 15.22 | 384 | 117 | 3.21 / 150.33 | 5 | 14 |
7 | 8 | 0.24 | 274 | 15.20 | 251 | 1045 | 4.26 / 151.37 | 5 | 140 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 16 | 15.20 | 383 | 93 | 0.09 / 142.92 | 6 | 6 |
2 | 7 | 2010.48 | 40 | 14.80 | 3038 | 1798 | 1.89 / 144.72 | 6 | 13 |
3 | 13 | 1359.64 | 20 | 14.92 | 2165 | 646 | 2.54 / 145.37 | 5 | 19 |
4 | 13 | 788.72 | 20 | 15.03 | 1387 | 417 | 2.95 / 145.78 | 5 | 23 |
5 | 13 | 197.40 | 20 | 15.20 | 541 | 164 | 3.12 / 145.95 | 5 | 16 |
6 | 13 | 88.76 | 20 | 15.22 | 381 | 116 | 3.24 / 146.06 | 5 | 13 |
7 | 8 | 0.12 | 278 | 15.20 | 249 | 1052 | 4.29 / 147.12 | 5 | 158 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 16 | 15.20 | 407 | 99 | 0.10 / 138.63 | 6 | 6 |
2 | 7 | 2003.40 | 40 | 14.80 | 3029 | 1793 | 1.89 / 140.43 | 6 | 13 |
3 | 13 | 1345.44 | 20 | 14.92 | 2144 | 640 | 2.53 / 141.07 | 5 | 19 |
4 | 13 | 780.20 | 20 | 15.04 | 1363 | 410 | 2.94 / 141.48 | 5 | 23 |
5 | 13 | 214.08 | 20 | 15.20 | 571 | 174 | 3.12 / 141.65 | 5 | 17 |
6 | 13 | 100.68 | 20 | 15.22 | 399 | 121 | 3.24 / 141.77 | 5 | 14 |
7 | 8 | -0.04 | 276 | 15.20 | 252 | 1057 | 4.29 / 142.83 | 5 | 136 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 16 | 15.20 | 384 | 93 | 0.09 / 134.34 | 6 | 6 |
2 | 7 | 2005.24 | 40 | 14.81 | 3025 | 1792 | 1.89 / 136.13 | 6 | 13 |
3 | 13 | 1367.76 | 20 | 14.92 | 2182 | 651 | 2.54 / 136.78 | 5 | 19 |
4 | 13 | 796.20 | 20 | 15.03 | 1397 | 420 | 2.96 / 137.20 | 5 | 24 |
5 | 13 | 206.96 | 20 | 15.20 | 561 | 171 | 3.13 / 137.37 | 5 | 16 |
6 | 13 | 97.88 | 20 | 15.22 | 395 | 120 | 3.25 / 137.49 | 5 | 14 |
7 | 8 | 0.04 | 276 | 15.20 | 249 | 1045 | 4.29 / 138.53 | 5 | 133 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 16 | 15.21 | 404 | 98 | 0.10 / 130.04 | 6 | 6 |
2 | 7 | 2010.96 | 40 | 14.81 | 3041 | 1801 | 1.90 / 131.84 | 6 | 13 |
3 | 13 | 1338.48 | 20 | 14.93 | 2130 | 636 | 2.54 / 132.48 | 5 | 19 |
4 | 13 | 787.84 | 20 | 15.04 | 1384 | 416 | 2.95 / 132.89 | 5 | 23 |
5 | 13 | 227.56 | 20 | 15.19 | 586 | 178 | 3.13 / 133.07 | 5 | 17 |
6 | 13 | 83.24 | 20 | 15.23 | 374 | 114 | 3.24 / 133.18 | 5 | 13 |
7 | 8 | 0.00 | 278 | 15.21 | 250 | 1057 | 4.30 / 134.24 | 5 | 148 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 16 | 15.21 | 405 | 99 | 0.10 / 125.75 | 6 | 6 |
2 | 7 | 2003.32 | 41 | 14.82 | 3028 | 1840 | 1.94 / 127.59 | 6 | 13 |
3 | 13 | 1372.84 | 20 | 14.93 | 2178 | 650 | 2.59 / 128.24 | 5 | 19 |
4 | 13 | 698.16 | 20 | 15.07 | 1257 | 379 | 2.97 / 128.62 | 5 | 23 |
5 | 13 | 192.68 | 20 | 15.21 | 538 | 164 | 3.13 / 128.78 | 5 | 16 |
6 | 13 | 84.96 | 20 | 15.23 | 378 | 115 | 3.25 / 128.90 | 5 | 14 |
7 | 8 | 0.08 | 276 | 15.21 | 249 | 1045 | 4.29 / 129.94 | 5 | 137 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 16 | 15.21 | 403 | 98 | 0.10 / 121.48 | 6 | 6 |
2 | 7 | 2013.96 | 40 | 14.82 | 3034 | 1799 | 1.90 / 123.28 | 6 | 12 |
3 | 13 | 1345.08 | 20 | 14.94 | 2142 | 640 | 2.54 / 123.92 | 5 | 19 |
4 | 13 | 778.28 | 20 | 15.05 | 1364 | 411 | 2.95 / 124.33 | 5 | 23 |
5 | 13 | 189.56 | 20 | 15.21 | 534 | 162 | 3.11 / 124.49 | 5 | 16 |
6 | 13 | 82.84 | 20 | 15.24 | 374 | 114 | 3.22 / 124.60 | 5 | 14 |
7 | 8 | 0.04 | 276 | 15.21 | 249 | 1045 | 4.27 / 125.65 | 5 | 134 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 16 | 15.21 | 381 | 93 | 0.09 / 117.25 | 6 | 6 |
2 | 7 | 2011.04 | 40 | 14.82 | 3040 | 1802 | 1.89 / 119.05 | 6 | 13 |
3 | 13 | 1303.44 | 20 | 14.94 | 2095 | 626 | 2.52 / 119.68 | 5 | 19 |
4 | 13 | 742.20 | 20 | 15.06 | 1317 | 397 | 2.92 / 120.07 | 5 | 23 |
5 | 13 | 154.88 | 20 | 15.22 | 485 | 148 | 3.07 / 120.22 | 5 | 16 |
6 | 13 | 83.84 | 20 | 15.23 | 377 | 115 | 3.18 / 120.33 | 5 | 15 |
7 | 8 | 0.04 | 276 | 15.21 | 249 | 1045 | 4.23 / 121.38 | 5 | 145 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 16 | 15.22 | 376 | 92 | 0.09 / 112.96 | 6 | 6 |
2 | 7 | 2008.16 | 40 | 14.83 | 3032 | 1799 | 1.89 / 114.76 | 6 | 13 |
3 | 13 | 1395.96 | 20 | 14.93 | 2211 | 660 | 2.55 / 115.42 | 5 | 19 |
4 | 13 | 820.08 | 20 | 15.04 | 1418 | 427 | 2.98 / 115.85 | 5 | 23 |
5 | 13 | 174.36 | 20 | 15.22 | 514 | 156 | 3.13 / 116.00 | 5 | 17 |
6 | 13 | 65.32 | 20 | 15.24 | 350 | 107 | 3.24 / 116.11 | 5 | 14 |
7 | 8 | 0.00 | 276 | 15.22 | 249 | 1046 | 4.29 / 117.15 | 5 | 141 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 16 | 15.22 | 381 | 93 | 0.09 / 108.69 | 6 | 6 |
2 | 7 | 2012.64 | 41 | 14.83 | 3031 | 1843 | 1.94 / 110.53 | 6 | 12 |
3 | 13 | 1357.28 | 20 | 14.94 | 2155 | 644 | 2.58 / 111.18 | 5 | 19 |
4 | 13 | 722.80 | 20 | 15.07 | 1291 | 389 | 2.97 / 111.57 | 5 | 23 |
5 | 13 | 184.72 | 20 | 15.22 | 524 | 160 | 3.13 / 111.73 | 5 | 16 |
6 | 13 | 80.40 | 20 | 15.24 | 369 | 112 | 3.24 / 111.84 | 5 | 13 |
7 | 8 | 0.08 | 276 | 15.22 | 245 | 1029 | 4.27 / 112.87 | 5 | 144 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 16 | 15.22 | 386 | 94 | 0.09 / 104.42 | 6 | 6 |
2 | 7 | 2002.52 | 40 | 14.83 | 3025 | 1794 | 1.89 / 106.21 | 6 | 13 |
3 | 13 | 1394.28 | 20 | 14.94 | 2206 | 659 | 2.55 / 106.87 | 5 | 19 |
4 | 13 | 767.76 | 20 | 15.06 | 1346 | 405 | 2.95 / 107.27 | 5 | 23 |
5 | 13 | 215.44 | 20 | 15.22 | 569 | 173 | 3.13 / 107.45 | 5 | 17 |
6 | 13 | 75.96 | 20 | 15.25 | 360 | 110 | 3.24 / 107.56 | 5 | 13 |
7 | 8 | 0.04 | 276 | 15.22 | 248 | 1042 | 4.28 / 108.60 | 5 | 132 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 16 | 15.21 | 417 | 101 | 0.10 / 100.12 | 6 | 6 |
2 | 7 | 2004.04 | 40 | 14.84 | 3031 | 1799 | 1.90 / 101.92 | 6 | 12 |
3 | 13 | 1425.44 | 20 | 14.93 | 2243 | 670 | 2.57 / 102.59 | 5 | 18 |
4 | 13 | 765.12 | 20 | 15.07 | 1354 | 408 | 2.98 / 103.00 | 5 | 23 |
5 | 13 | 200.80 | 20 | 15.22 | 548 | 167 | 3.15 / 103.16 | 5 | 18 |
6 | 13 | 86.00 | 20 | 15.24 | 380 | 116 | 3.26 / 103.28 | 5 | 15 |
7 | 8 | 0.28 | 276 | 15.23 | 248 | 1042 | 4.30 / 104.32 | 5 | 146 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 16 | 15.21 | 401 | 98 | 0.10 / 95.80 | 5 | 6 |
2 | 7 | 2003.40 | 40 | 14.84 | 3033 | 1800 | 1.90 / 97.60 | 6 | 13 |
3 | 13 | 1361.56 | 20 | 14.96 | 2165 | 648 | 2.55 / 98.25 | 5 | 19 |
4 | 13 | 850.68 | 20 | 15.04 | 1476 | 444 | 2.99 / 98.69 | 5 | 24 |
5 | 13 | 122.72 | 20 | 15.24 | 441 | 134 | 3.12 / 98.83 | 5 | 19 |
6 | 13 | 58.60 | 20 | 15.25 | 346 | 106 | 3.23 / 98.93 | 5 | 17 |
7 | 8 | 0.04 | 276 | 15.22 | 258 | 1084 | 4.31 / 100.02 | 5 | 152 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 16 | 15.22 | 392 | 95 | 0.10 / 91.54 | 5 | 6 |
2 | 7 | 2003.04 | 41 | 14.84 | 3027 | 1842 | 1.94 / 93.38 | 6 | 13 |
3 | 13 | 1340.76 | 20 | 14.96 | 2129 | 637 | 2.57 / 94.02 | 5 | 19 |
4 | 13 | 690.68 | 20 | 15.09 | 1249 | 377 | 2.95 / 94.39 | 5 | 24 |
5 | 13 | 91.24 | 20 | 15.25 | 399 | 122 | 3.07 / 94.52 | 5 | 21 |
6 | 13 | 31.16 | 20 | 15.25 | 315 | 96 | 3.17 / 94.61 | 5 | 20 |
7 | 8 | 0.04 | 274 | 15.22 | 262 | 1093 | 4.26 / 95.70 | 5 | 145 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 16 | 15.22 | 403 | 98 | 0.10 / 87.32 | 5 | 6 |
2 | 7 | 2012.00 | 40 | 14.85 | 3042 | 1807 | 1.91 / 89.12 | 6 | 13 |
3 | 13 | 1352.92 | 20 | 14.96 | 2154 | 644 | 2.55 / 89.77 | 5 | 19 |
4 | 13 | 698.56 | 20 | 15.09 | 1255 | 379 | 2.93 / 90.15 | 5 | 25 |
5 | 13 | 75.52 | 20 | 15.26 | 379 | 116 | 3.04 / 90.26 | 5 | 20 |
6 | 13 | 24.40 | 20 | 15.26 | 305 | 93 | 3.14 / 90.35 | 5 | 19 |
7 | 8 | -0.08 | 274 | 15.22 | 261 | 1088 | 4.23 / 91.44 | 5 | 138 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 16 | 15.22 | 395 | 96 | 0.10 / 83.09 | 5 | 6 |
2 | 7 | 2002.16 | 41 | 14.85 | 3028 | 1844 | 1.94 / 84.93 | 6 | 13 |
3 | 13 | 1306.92 | 20 | 14.97 | 2101 | 629 | 2.57 / 85.56 | 5 | 19 |
4 | 13 | 660.20 | 20 | 15.10 | 1211 | 366 | 2.93 / 85.92 | 5 | 25 |
5 | 13 | 73.44 | 20 | 15.26 | 376 | 115 | 3.05 / 86.04 | 5 | 21 |
6 | 13 | 23.72 | 20 | 15.26 | 308 | 94 | 3.14 / 86.13 | 5 | 20 |
7 | 8 | 0.08 | 274 | 15.22 | 260 | 1084 | 4.23 / 87.22 | 5 | 136 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 16 | 15.23 | 402 | 98 | 0.10 / 78.83 | 5 | 6 |
2 | 7 | 2014.80 | 40 | 14.86 | 3050 | 1813 | 1.91 / 80.64 | 6 | 13 |
3 | 13 | 1353.96 | 20 | 14.96 | 2158 | 646 | 2.56 / 81.29 | 5 | 19 |
4 | 13 | 752.52 | 20 | 15.07 | 1337 | 403 | 2.96 / 81.69 | 5 | 24 |
5 | 13 | 85.04 | 20 | 15.26 | 395 | 121 | 3.08 / 81.81 | 5 | 19 |
6 | 13 | 28.88 | 20 | 15.26 | 310 | 95 | 3.17 / 81.90 | 5 | 19 |
7 | 8 | -0.08 | 276 | 15.23 | 258 | 1084 | 4.26 / 82.99 | 5 | 143 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 16 | 15.23 | 395 | 96 | 0.10 / 74.61 | 6 | 6 |
2 | 7 | 2008.32 | 40 | 14.86 | 3039 | 1806 | 1.90 / 76.41 | 6 | 13 |
3 | 13 | 1346.00 | 20 | 14.96 | 2141 | 641 | 2.54 / 77.06 | 5 | 19 |
4 | 13 | 693.96 | 20 | 15.09 | 1246 | 376 | 2.92 / 77.43 | 5 | 24 |
5 | 13 | 101.68 | 20 | 15.25 | 417 | 127 | 3.05 / 77.56 | 5 | 19 |
6 | 13 | 42.24 | 20 | 15.26 | 325 | 99 | 3.15 / 77.66 | 5 | 17 |
7 | 8 | 0.08 | 274 | 15.23 | 257 | 1072 | 4.22 / 78.73 | 5 | 147 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 16 | 15.23 | 379 | 92 | 0.09 / 70.37 | 6 | 6 |
2 | 7 | 2009.88 | 40 | 14.86 | 3038 | 1806 | 1.90 / 72.18 | 6 | 13 |
3 | 13 | 1355.04 | 20 | 14.97 | 2158 | 646 | 2.54 / 72.82 | 5 | 19 |
4 | 13 | 675.24 | 20 | 15.10 | 1224 | 370 | 2.91 / 73.19 | 5 | 24 |
5 | 13 | 158.56 | 20 | 15.24 | 501 | 153 | 3.07 / 73.34 | 5 | 21 |
6 | 13 | 53.72 | 20 | 15.26 | 342 | 104 | 3.17 / 73.45 | 5 | 17 |
7 | 8 | -0.20 | 274 | 15.23 | 255 | 1064 | 4.24 / 74.51 | 5 | 137 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 16 | 15.23 | 404 | 98 | 0.10 / 66.19 | 6 | 6 |
2 | 7 | 2003.80 | 40 | 14.86 | 3033 | 1803 | 1.90 / 67.99 | 6 | 13 |
3 | 13 | 1334.36 | 20 | 14.98 | 2127 | 637 | 2.54 / 68.63 | 5 | 19 |
4 | 13 | 629.84 | 20 | 15.12 | 1163 | 352 | 2.89 / 68.98 | 5 | 24 |
5 | 13 | 122.84 | 20 | 15.25 | 442 | 135 | 3.03 / 69.12 | 5 | 18 |
6 | 13 | 57.80 | 20 | 15.27 | 347 | 106 | 3.13 / 69.22 | 5 | 17 |
7 | 8 | 0.08 | 274 | 15.24 | 252 | 1052 | 4.18 / 70.28 | 5 | 130 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 16 | 15.23 | 386 | 94 | 0.09 / 61.94 | 6 | 6 |
2 | 7 | 2008.96 | 40 | 14.87 | 3041 | 1809 | 1.90 / 63.75 | 6 | 13 |
3 | 13 | 1340.80 | 20 | 14.98 | 2143 | 642 | 2.54 / 64.39 | 5 | 19 |
4 | 13 | 714.84 | 20 | 15.10 | 1284 | 388 | 2.93 / 64.78 | 5 | 23 |
5 | 13 | 158.16 | 20 | 15.25 | 489 | 149 | 3.08 / 64.93 | 5 | 18 |
6 | 13 | 52.64 | 20 | 15.27 | 334 | 102 | 3.18 / 65.03 | 5 | 15 |
7 | 8 | -0.04 | 278 | 15.24 | 251 | 1063 | 4.25 / 66.09 | 5 | 150 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 16 | 15.24 | 404 | 99 | 0.10 / 57.64 | 6 | 6 |
2 | 7 | 2011.12 | 40 | 14.87 | 3037 | 1806 | 1.90 / 59.45 | 6 | 13 |
3 | 13 | 1393.28 | 20 | 14.98 | 2197 | 658 | 2.56 / 60.11 | 5 | 19 |
4 | 13 | 744.24 | 20 | 15.09 | 1323 | 399 | 2.96 / 60.51 | 5 | 24 |
5 | 13 | 168.08 | 20 | 15.25 | 510 | 156 | 3.12 / 60.66 | 5 | 19 |
6 | 13 | 59.60 | 20 | 15.27 | 348 | 106 | 3.22 / 60.77 | 5 | 16 |
7 | 8 | 0.08 | 278 | 15.24 | 254 | 1076 | 4.30 / 61.85 | 5 | 147 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 16 | 15.24 | 382 | 93 | 0.09 / 53.34 | 6 | 6 |
2 | 7 | 2011.08 | 40 | 14.88 | 3039 | 1809 | 1.90 / 55.15 | 6 | 13 |
3 | 13 | 1448.60 | 20 | 14.96 | 2271 | 679 | 2.58 / 55.83 | 5 | 18 |
4 | 13 | 709.16 | 20 | 15.10 | 1275 | 385 | 2.97 / 56.21 | 5 | 24 |
5 | 13 | 168.12 | 20 | 15.25 | 511 | 156 | 3.12 / 56.37 | 5 | 19 |
6 | 13 | 63.76 | 20 | 15.27 | 353 | 108 | 3.23 / 56.47 | 5 | 15 |
7 | 8 | 0.04 | 278 | 15.24 | 253 | 1072 | 4.30 / 57.55 | 5 | 149 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 16 | 15.24 | 384 | 94 | 0.09 / 49.05 | 6 | 6 |
2 | 7 | 2003.84 | 41 | 14.88 | 3015 | 1839 | 1.93 / 50.89 | 6 | 13 |
3 | 13 | 1336.28 | 20 | 14.99 | 2129 | 638 | 2.57 / 51.53 | 5 | 19 |
4 | 13 | 728.88 | 20 | 15.10 | 1299 | 392 | 2.96 / 51.92 | 5 | 23 |
5 | 13 | 172.44 | 20 | 15.25 | 508 | 155 | 3.12 / 52.07 | 5 | 17 |
6 | 13 | 66.16 | 20 | 15.27 | 350 | 107 | 3.23 / 52.18 | 5 | 14 |
7 | 8 | 0.04 | 278 | 15.25 | 251 | 1064 | 4.29 / 53.24 | 5 | 143 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 16 | 15.25 | 380 | 93 | 0.09 / 44.77 | 6 | 6 |
2 | 7 | 2003.36 | 40 | 14.89 | 3027 | 1803 | 1.90 / 46.57 | 6 | 12 |
3 | 13 | 1393.40 | 20 | 14.98 | 2199 | 659 | 2.55 / 47.23 | 5 | 18 |
4 | 13 | 743.16 | 20 | 15.10 | 1320 | 399 | 2.95 / 47.63 | 5 | 23 |
5 | 13 | 192.60 | 20 | 15.25 | 534 | 163 | 3.12 / 47.79 | 5 | 16 |
6 | 13 | 80.20 | 20 | 15.28 | 369 | 113 | 3.23 / 47.90 | 5 | 14 |
7 | 8 | 0.00 | 278 | 15.25 | 248 | 1051 | 4.28 / 48.95 | 5 | 135 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 16 | 15.24 | 385 | 94 | 0.09 / 40.47 | 6 | 6 |
2 | 7 | 2009.80 | 40 | 14.89 | 3027 | 1803 | 1.90 / 42.27 | 6 | 12 |
3 | 13 | 1408.32 | 20 | 14.98 | 2225 | 667 | 2.56 / 42.94 | 5 | 18 |
4 | 13 | 759.00 | 20 | 15.10 | 1336 | 403 | 2.97 / 43.34 | 5 | 23 |
5 | 13 | 207.20 | 20 | 15.25 | 553 | 169 | 3.14 / 43.51 | 5 | 16 |
6 | 13 | 96.04 | 20 | 15.27 | 390 | 119 | 3.25 / 43.63 | 5 | 14 |
7 | 8 | 0.12 | 278 | 15.25 | 247 | 1047 | 4.30 / 44.67 | 5 | 135 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 16 | 15.25 | 384 | 94 | 0.09 / 36.14 | 6 | 6 |
2 | 7 | 2007.80 | 41 | 14.89 | 3025 | 1847 | 1.94 / 37.98 | 6 | 12 |
3 | 13 | 1382.72 | 20 | 14.99 | 2185 | 655 | 2.60 / 38.64 | 5 | 18 |
4 | 13 | 772.60 | 20 | 15.10 | 1355 | 409 | 3.00 / 39.05 | 5 | 23 |
5 | 13 | 212.92 | 20 | 15.25 | 560 | 171 | 3.18 / 39.22 | 5 | 16 |
6 | 13 | 72.00 | 20 | 15.28 | 352 | 108 | 3.28 / 39.33 | 5 | 12 |
7 | 8 | 0.16 | 280 | 15.26 | 245 | 1047 | 4.33 / 40.37 | 5 | 166 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 15 | 15.25 | 377 | 86 | 0.09 / 31.82 | 6 | 6 |
2 | 3 | 1543.48 | 1 | 15.11 | 2433 | 37 | 0.12 / 31.86 | 5 | 10 |
3 | 7 | 2005.12 | 40 | 14.89 | 3023 | 1800 | 1.92 / 33.66 | 10 | 12 |
4 | 13 | 1389.72 | 20 | 14.99 | 2189 | 656 | 2.58 / 34.31 | 5 | 18 |
5 | 13 | 741.40 | 20 | 15.11 | 1303 | 394 | 2.97 / 34.71 | 5 | 23 |
6 | 13 | 233.52 | 20 | 15.25 | 591 | 180 | 3.15 / 34.89 | 5 | 17 |
7 | 13 | 84.28 | 20 | 15.28 | 372 | 114 | 3.27 / 35.00 | 5 | 13 |
8 | 8 | 0.12 | 280 | 15.26 | 244 | 1043 | 4.31 / 36.04 | 5 | 143 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 23 | 15.25 | 379 | 133 | 0.13 / 27.56 | 6 | 6 |
2 | 3 | 1244.84 | -4 | 15.57 | 1 | 0 | 0.00 / 27.56 | 6 | 6 |
3 | 7 | 2012.64 | 40 | 14.90 | 3044 | 1814 | 1.95 / 29.37 | 6 | 12 |
4 | 13 | 1352.20 | 20 | 15.00 | 2157 | 647 | 2.59 / 30.02 | 5 | 18 |
5 | 13 | 718.44 | 20 | 15.12 | 1284 | 388 | 2.98 / 30.41 | 5 | 23 |
6 | 13 | 216.36 | 20 | 15.25 | 566 | 173 | 3.16 / 30.58 | 5 | 16 |
7 | 13 | 71.12 | 20 | 15.29 | 352 | 108 | 3.26 / 30.69 | 5 | 12 |
8 | 8 | 0.08 | 280 | 15.26 | 245 | 1047 | 4.31 / 31.73 | 5 | 140 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 17 | 15.25 | 395 | 102 | 0.10 / 22.91 | 6 | 6 |
2 | 10 | 1500.00 | 5 | 15.08 | 2314 | 174 | 0.28 / 23.08 | 5 | 6 |
3 | 10 | 1505.44 | 3 | 15.09 | 2339 | 106 | 0.38 / 23.19 | 5 | 7 |
4 | 7 | 2008.52 | 40 | 14.90 | 3031 | 1806 | 2.19 / 25.00 | 7 | 12 |
5 | 13 | 1405.76 | 20 | 14.99 | 2220 | 666 | 2.85 / 25.66 | 5 | 18 |
6 | 13 | 789.36 | 20 | 15.10 | 1378 | 416 | 3.27 / 26.08 | 5 | 22 |
7 | 13 | 232.36 | 20 | 15.25 | 589 | 180 | 3.45 / 26.26 | 5 | 16 |
8 | 13 | 86.96 | 20 | 15.29 | 375 | 115 | 3.57 / 26.37 | 5 | 12 |
9 | 8 | 0.08 | 280 | 15.26 | 246 | 1051 | 4.62 / 27.42 | 5 | 144 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 16 | 15.25 | 379 | 92 | 0.09 / 18.59 | 6 | 6 |
2 | 3 | 1548.28 | 1 | 15.12 | 2445 | 37 | 0.13 / 18.63 | 5 | 10 |
3 | 7 | 2005.08 | 40 | 14.90 | 3019 | 1799 | 1.93 / 20.43 | 10 | 12 |
4 | 13 | 1310.28 | 20 | 15.01 | 2091 | 628 | 2.56 / 21.05 | 5 | 19 |
5 | 13 | 757.68 | 20 | 15.11 | 1335 | 403 | 2.96 / 21.46 | 5 | 22 |
6 | 13 | 244.52 | 20 | 15.25 | 605 | 185 | 3.14 / 21.64 | 5 | 16 |
7 | 13 | 98.48 | 20 | 15.28 | 388 | 119 | 3.26 / 21.76 | 5 | 12 |
8 | 8 | 0.08 | 282 | 15.26 | 243 | 1046 | 4.31 / 22.81 | 5 | 136 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 16 | 15.25 | 375 | 91 | 0.09 / 14.33 | 6 | 6 |
2 | 7 | 2009.88 | 40 | 14.91 | 3018 | 1800 | 1.89 / 16.13 | 6 | 12 |
3 | 13 | 1379.28 | 20 | 15.00 | 2184 | 655 | 2.55 / 16.79 | 5 | 18 |
4 | 13 | 730.44 | 20 | 15.12 | 1295 | 392 | 2.94 / 17.18 | 5 | 22 |
5 | 13 | 221.12 | 20 | 15.26 | 568 | 173 | 3.11 / 17.35 | 5 | 15 |
6 | 13 | 76.28 | 20 | 15.29 | 356 | 109 | 3.22 / 17.46 | 5 | 12 |
7 | 8 | 0.12 | 280 | 15.26 | 243 | 1038 | 4.26 / 18.50 | 5 | 157 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 16 | 15.25 | 371 | 91 | 0.09 / 10.07 | 6 | 6 |
2 | 7 | 2011.88 | 40 | 14.91 | 3035 | 1810 | 1.90 / 11.88 | 6 | 12 |
3 | 13 | 1383.28 | 20 | 15.00 | 2193 | 658 | 2.56 / 12.54 | 5 | 18 |
4 | 13 | 736.96 | 20 | 15.13 | 1304 | 395 | 2.95 / 12.93 | 5 | 22 |
5 | 13 | 226.28 | 20 | 15.26 | 573 | 175 | 3.13 / 13.11 | 5 | 15 |
6 | 13 | 47.84 | 20 | 15.30 | 313 | 96 | 3.22 / 13.21 | 5 | 11 |
7 | 8 | 0.16 | 280 | 15.26 | 242 | 1034 | 4.26 / 14.24 | 5 | 152 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 14 | 15.21 | 373 | 79 | 0.08 / 5.75 | 6 | 6 |
2 | 10 | 1501.08 | 3 | 15.09 | 2354 | 107 | 0.19 / 5.86 | 5 | 7 |
3 | 7 | 2011.36 | 40 | 14.91 | 3025 | 1804 | 1.99 / 7.66 | 7 | 12 |
4 | 13 | 1351.24 | 20 | 15.01 | 2132 | 640 | 2.63 / 8.30 | 5 | 19 |
5 | 13 | 707.24 | 20 | 15.13 | 1258 | 381 | 3.01 / 8.68 | 5 | 22 |
6 | 13 | 196.28 | 20 | 15.26 | 534 | 163 | 3.17 / 8.84 | 5 | 15 |
7 | 13 | 83.44 | 20 | 15.28 | 366 | 112 | 3.29 / 8.95 | 5 | 13 |
8 | 8 | 0.00 | 278 | 15.26 | 242 | 1027 | 4.31 / 9.98 | 5 | 139 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 18 | 15.45 | 354 | 98 | 0.10 / 1.62 | 6 | 6 |
2 | 3 | 1361.44 | -2 | 15.60 | 1 | 0 | 0.00 / 1.62 | 6 | 6 |
3 | 7 | 2008.88 | 40 | 14.90 | 3039 | 1811 | 1.91 / 3.43 | 6 | 12 |
4 | 13 | 1299.28 | 20 | 14.99 | 2079 | 623 | 2.53 / 4.05 | 5 | 19 |
5 | 13 | 675.84 | 20 | 15.11 | 1214 | 367 | 2.90 / 4.42 | 5 | 21 |
6 | 13 | 174.52 | 20 | 15.23 | 498 | 152 | 3.05 / 4.57 | 5 | 15 |
7 | 13 | 35.96 | 20 | 15.26 | 291 | 89 | 3.14 / 4.66 | 5 | 12 |
8 | 8 | 0.08 | 278 | 15.23 | 239 | 1012 | 4.15 / 5.67 | 5 | 132 |
Average= | 2.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 18 | 15.60 | 366 | 103 | 0.10 / 0.10 | 6 | 6 |
2 | 7 | 122.36 | 40 | 15.58 | 387 | 241 | 0.34 / 0.34 | 6 | 6 |
3 | 13 | 147.96 | 20 | 15.56 | 419 | 130 | 0.47 / 0.47 | 6 | 6 |
4 | 13 | 121.56 | 20 | 15.55 | 375 | 117 | 0.59 / 0.59 | 6 | 7 |
5 | 8 | 0.08 | 287 | 15.51 | 208 | 926 | 1.52 / 1.52 | 6 | -99 |
Average= | 1.52 (KJ/cycle) |