SIO Argo Site:
Pump Diagnostics Page   



Serial= 7873 WMO= 4903550

Return

←PreviousNext→

Cycle 107 GMT 23/11/2024 13:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 19 14.72 383 107 0.11 / 446.25 8 11
2 7 2013.48 41 14.36 2656 1564 1.67 / 447.81 11 13
3 13 1618.84 20 14.37 2227 640 2.31 / 448.46 9 14
4 13 1007.32 20 14.44 1553 449 2.76 / 448.90 10 15
5 13 247.76 20 14.67 598 175 2.93 / 449.08 10 15
6 13 47.48 20 14.74 331 98 3.03 / 449.18 10 14
7 8 0.04 304 14.71 259 1158 4.19 / 450.33 10 235
Average= 4.17
(KJ/cycle)

Cycle 106 GMT 18/11/2024 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 19 14.61 383 106 0.11 / 441.97 8 11
2 7 2011.80 40 14.39 2651 1526 1.63 / 443.50 11 13
3 13 1568.48 20 14.41 2157 622 2.25 / 444.12 9 14
4 13 1008.00 20 14.47 1550 449 2.70 / 444.57 10 14
5 13 514.24 20 14.58 941 274 2.98 / 444.85 10 15
6 13 110.80 20 14.72 412 121 3.10 / 444.97 10 14
7 13 37.48 20 14.75 312 92 3.19 / 445.06 10 14
8 8 -0.04 287 14.72 257 1086 4.28 / 446.14 10 187
Average= 4.17
(KJ/cycle)

Cycle 105 GMT 13/11/2024 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 19 14.73 386 108 0.11 / 433.48 8 11
2 7 1778.24 40 14.44 2380 1375 1.48 / 434.86 11 13
3 13 1778.36 20 14.39 2374 683 2.17 / 435.54 9 14
4 13 1778.36 20 14.34 2374 681 2.85 / 436.22 10 14
5 13 1778.32 20 14.28 2372 677 3.52 / 436.90 10 14
6 13 1778.36 20 14.23 2379 677 4.20 / 437.57 10 14
7 13 1778.40 20 14.17 2372 672 4.87 / 438.25 10 14
8 13 1778.36 20 14.14 2352 665 5.54 / 438.91 10 14
9 13 1778.36 20 14.07 2380 670 6.21 / 439.58 10 14
10 13 1778.36 20 14.02 2401 673 6.88 / 440.26 10 14
11 13 1748.72 20 13.99 2338 654 7.54 / 440.91 10 15
12 8 -0.12 246 14.60 267 959 8.49 / 441.87 11 196
Average= 4.17
(KJ/cycle)

Cycle 104 GMT 8/11/2024 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 19 14.73 379 106 0.11 / 429.46 8 11
2 7 1855.36 40 14.41 2476 1427 1.53 / 430.88 11 13
3 13 1489.16 20 14.42 2067 596 2.13 / 431.48 9 14
4 13 977.68 20 14.47 1525 441 2.57 / 431.92 10 15
5 13 300.04 20 14.66 662 194 2.76 / 432.12 10 15
6 13 97.92 20 14.73 391 115 2.88 / 432.23 10 14
7 8 0.04 304 14.73 255 1142 4.02 / 433.37 10 208
Average= 4.13
(KJ/cycle)

Cycle 103 GMT 3/11/2024 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 19 14.72 400 112 0.11 / 425.44 8 11
2 7 1821.72 40 14.42 2439 1407 1.52 / 426.85 11 14
3 13 1567.00 20 14.41 2152 620 2.14 / 427.47 9 14
4 13 960.12 20 14.48 1502 435 2.57 / 427.90 10 14
5 13 323.92 20 14.66 692 203 2.78 / 428.10 10 15
6 13 84.92 20 14.74 373 110 2.89 / 428.21 10 14
7 8 -0.04 304 14.73 254 1137 4.02 / 429.35 11 207
Average= 4.13
(KJ/cycle)

Cycle 102 GMT 29/10/2024 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 19 14.73 374 105 0.10 / 421.31 8 11
2 7 1891.08 41 14.39 2531 1493 1.60 / 422.80 11 13
3 13 1500.36 20 14.40 2092 602 2.20 / 423.41 9 14
4 13 994.72 20 14.46 1539 445 2.65 / 423.85 10 15
5 13 340.56 20 14.64 720 211 2.86 / 424.06 10 15
6 13 82.64 20 14.73 374 110 2.97 / 424.17 10 14
7 8 -0.04 302 14.72 260 1156 4.12 / 425.33 11 191
Average= 4.13
(KJ/cycle)

Cycle 101 GMT 24/10/2024 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 19 14.74 389 109 0.11 / 417.17 8 11
2 7 2010.16 40 14.36 2653 1524 1.63 / 418.69 11 13
3 13 1535.80 20 14.38 2151 619 2.25 / 419.31 9 14
4 13 954.64 20 14.46 1495 432 2.68 / 419.74 10 15
5 13 361.20 20 14.64 736 216 2.90 / 419.96 10 14
6 13 113.48 20 14.73 405 119 3.02 / 420.08 10 14
7 8 0.04 304 14.73 252 1128 4.15 / 421.21 10 209
Average= 4.13
(KJ/cycle)

Cycle 100 GMT 19/10/2024 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 19 14.72 376 105 0.11 / 413.00 8 11
2 7 2007.88 41 14.37 2647 1560 1.66 / 414.56 11 13
3 13 1512.96 20 14.39 2101 605 2.27 / 415.16 9 14
4 13 971.60 20 14.46 1515 438 2.71 / 415.60 10 14
5 13 302.04 20 14.67 664 195 2.90 / 415.80 10 14
6 13 100.64 20 14.73 394 116 3.02 / 415.91 10 14
7 8 -0.04 304 14.73 256 1146 4.16 / 417.06 10 242
Average= 4.13
(KJ/cycle)

Cycle 99 GMT 14/10/2024 7:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 19 14.74 376 105 0.11 / 408.85 8 11
2 7 2013.20 40 14.37 2636 1515 1.62 / 410.37 11 13
3 13 1550.72 20 14.39 2122 611 2.23 / 410.98 9 14
4 13 969.28 20 14.46 1512 437 2.67 / 411.41 10 14
5 13 323.00 20 14.65 691 202 2.87 / 411.62 10 14
6 13 108.28 20 14.72 406 120 2.99 / 411.74 10 14
7 13 14.80 20 14.76 281 83 3.07 / 411.82 10 14
8 8 0.28 285 14.72 256 1074 4.15 / 412.89 10 194
Average= 4.13
(KJ/cycle)

Cycle 98 GMT 9/10/2024 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 19 14.74 381 107 0.11 / 404.68 8 11
2 7 2011.20 40 14.37 2620 1506 1.61 / 406.19 11 13
3 13 1550.04 20 14.38 2136 614 2.23 / 406.80 9 14
4 13 934.12 20 14.47 1468 425 2.65 / 407.23 10 14
5 13 447.48 20 14.61 848 248 2.90 / 407.47 10 15
6 13 135.48 20 14.72 439 129 3.03 / 407.60 10 14
7 13 14.00 20 14.76 274 81 3.11 / 407.68 10 13
8 8 0.04 285 14.72 253 1061 4.17 / 408.75 10 156
Average= 4.13
(KJ/cycle)

Cycle 97 GMT 4/10/2024 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 19 14.73 387 108 0.11 / 400.53 8 11
2 7 2011.76 40 14.38 2613 1503 1.61 / 402.04 11 13
3 13 1528.72 20 14.40 2089 602 2.21 / 402.64 9 14
4 13 1006.44 20 14.45 1554 449 2.66 / 403.09 10 14
5 13 394.44 20 14.64 779 228 2.89 / 403.32 10 14
6 13 144.08 20 14.72 444 131 3.02 / 403.45 10 14
7 8 0.16 306 14.74 250 1128 4.15 / 404.57 10 185
Average= 4.13
(KJ/cycle)

Cycle 96 GMT 29/ 9/2024 5:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 19 14.72 396 111 0.11 / 396.33 8 11
2 7 2010.36 40 14.38 2630 1513 1.62 / 397.85 11 13
3 13 1562.60 20 14.41 2135 615 2.24 / 398.46 9 14
4 13 1035.40 20 14.45 1594 461 2.70 / 398.92 10 14
5 13 407.16 20 14.63 803 235 2.93 / 399.16 10 15
6 13 121.72 20 14.73 420 124 3.06 / 399.28 10 14
7 8 0.12 306 14.74 254 1146 4.20 / 400.43 10 226
Average= 4.13
(KJ/cycle)

Cycle 95 GMT 24/ 9/2024 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 19 14.71 395 110 0.11 / 392.21 8 11
2 7 2009.84 40 14.37 2639 1517 1.63 / 393.73 11 13
3 13 1564.24 20 14.40 2148 619 2.25 / 394.35 9 14
4 13 930.16 20 14.47 1472 426 2.67 / 394.77 10 15
5 13 232.96 20 14.68 580 170 2.84 / 394.94 10 15
6 13 41.40 20 14.74 329 97 2.94 / 395.04 10 14
7 13 17.72 20 14.75 294 87 3.03 / 395.13 10 14
8 8 0.08 282 14.71 264 1095 4.12 / 396.22 10 222
Average= 4.13
(KJ/cycle)

Cycle 94 GMT 19/ 9/2024 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 19 14.73 379 106 0.11 / 387.98 8 11
2 7 2006.20 40 14.38 2639 1518 1.62 / 389.50 11 13
3 13 1559.48 20 14.40 2132 614 2.24 / 390.12 9 14
4 13 1084.44 20 14.44 1645 475 2.71 / 390.59 10 14
5 13 357.00 20 14.64 743 218 2.93 / 390.81 10 15
6 13 60.00 20 14.74 351 103 3.03 / 390.91 10 14
7 13 21.28 20 14.75 295 87 3.12 / 391.00 10 14
8 8 0.08 287 14.72 261 1103 4.22 / 392.10 10 222
Average= 4.13
(KJ/cycle)

Cycle 93 GMT 14/ 9/2024 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 19 14.72 379 106 0.11 / 383.80 8 11
2 7 2009.04 40 14.39 2621 1509 1.61 / 385.31 11 13
3 13 1494.36 20 14.41 2062 594 2.21 / 385.90 9 14
4 13 1022.76 20 14.45 1575 455 2.66 / 386.36 10 14
5 13 393.12 20 14.63 784 229 2.89 / 386.59 10 15
6 13 104.20 20 14.73 398 117 3.01 / 386.70 10 14
7 13 35.56 20 14.75 310 91 3.10 / 386.80 10 14
8 8 0.08 287 14.72 256 1082 4.18 / 387.88 10 181
Average= 4.13
(KJ/cycle)

Cycle 92 GMT 9/ 9/2024 2:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 19 14.73 374 105 0.10 / 379.62 8 11
2 7 2012.28 40 14.38 2637 1517 1.62 / 381.14 11 13
3 13 1577.16 20 14.40 2149 619 2.24 / 381.76 9 14
4 13 957.84 20 14.47 1501 434 2.67 / 382.19 10 15
5 13 364.12 20 14.64 748 219 2.89 / 382.41 10 15
6 13 105.20 20 14.72 400 118 3.01 / 382.53 10 14
7 13 33.20 20 14.75 306 90 3.10 / 382.62 10 14
8 8 0.08 285 14.72 256 1074 4.18 / 383.69 10 191
Average= 4.13
(KJ/cycle)

Cycle 91 GMT 4/ 9/2024 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 19 14.73 385 108 0.11 / 375.40 8 11
2 7 2012.12 40 14.39 2617 1506 1.61 / 376.91 11 13
3 13 1643.60 20 14.40 2222 640 2.25 / 377.55 9 14
4 13 960.12 20 14.46 1510 437 2.69 / 377.98 10 14
5 13 467.72 20 14.60 883 258 2.95 / 378.24 10 15
6 13 96.44 20 14.73 389 115 3.06 / 378.36 10 14
7 13 31.12 20 14.76 302 89 3.15 / 378.45 10 14
8 8 -0.04 287 14.72 254 1073 4.23 / 379.52 11 233
Average= 4.13
(KJ/cycle)

Cycle 90 GMT 30/ 8/2024 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 19 14.73 381 107 0.11 / 371.17 8 11
2 7 2009.12 40 14.38 2633 1515 1.62 / 372.68 11 13
3 13 1603.08 20 14.40 2181 628 2.25 / 373.31 9 14
4 13 1067.48 20 14.44 1626 470 2.72 / 373.78 10 14
5 13 418.76 20 14.63 814 238 2.96 / 374.02 10 15
6 13 127.68 20 14.73 422 124 3.08 / 374.14 10 14
7 13 27.72 20 14.76 291 86 3.17 / 374.23 10 13
8 8 -0.04 287 14.73 252 1065 4.23 / 375.29 11 247
Average= 4.12
(KJ/cycle)

Cycle 89 GMT 25/ 8/2024 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 19 14.73 376 105 0.11 / 366.98 8 11
2 7 2007.84 40 14.39 2626 1512 1.62 / 368.49 11 13
3 13 1592.72 20 14.40 2166 624 2.24 / 369.11 9 14
4 13 1010.48 20 14.46 1560 451 2.69 / 369.57 10 14
5 13 377.68 20 14.64 761 223 2.91 / 369.79 10 14
6 13 98.04 20 14.74 390 115 3.03 / 369.90 10 14
7 13 17.16 20 14.77 280 83 3.11 / 369.99 10 14
8 8 0.12 287 14.73 254 1074 4.19 / 371.06 11 201
Average= 4.12
(KJ/cycle)

Cycle 88 GMT 19/ 8/2024 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 19 14.73 381 107 0.11 / 362.80 8 11
2 7 2005.20 40 14.38 2636 1516 1.62 / 364.31 11 13
3 13 1600.80 20 14.40 2172 626 2.25 / 364.94 9 14
4 13 1036.24 20 14.45 1592 460 2.71 / 365.40 10 14
5 13 351.84 20 14.65 727 213 2.92 / 365.61 10 15
6 13 76.96 20 14.74 363 107 3.03 / 365.72 10 14
7 8 0.16 306 14.73 256 1154 4.18 / 366.87 10 203
Average= 4.12
(KJ/cycle)

Cycle 87 GMT 14/ 8/2024 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 19 14.74 378 106 0.11 / 358.54 8 11
2 7 2013.68 40 14.38 2646 1522 1.63 / 360.06 11 13
3 13 1606.52 20 14.39 2185 629 2.26 / 360.69 9 14
4 13 1072.16 20 14.44 1619 468 2.72 / 361.16 10 14
5 13 467.20 20 14.60 874 255 2.98 / 361.41 10 15
6 13 116.52 20 14.73 413 122 3.10 / 361.53 10 14
7 13 21.80 20 14.76 288 85 3.19 / 361.62 10 14
8 8 0.08 287 14.73 254 1074 4.26 / 362.69 10 187
Average= 4.12
(KJ/cycle)

Cycle 86 GMT 9/ 8/2024 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 19 14.74 377 106 0.11 / 354.38 8 11
2 7 2004.92 40 14.38 2618 1506 1.61 / 355.89 11 13
3 13 1543.56 20 14.41 2113 609 2.22 / 356.50 9 14
4 13 988.52 20 14.47 1533 444 2.66 / 356.94 10 14
5 13 344.96 20 14.66 713 209 2.87 / 357.15 10 14
6 13 144.92 20 14.73 448 132 3.01 / 357.28 10 14
7 13 15.12 20 14.78 275 81 3.09 / 357.36 10 13
8 8 0.12 287 14.74 253 1070 4.16 / 358.43 10 219
Average= 4.12
(KJ/cycle)

Cycle 85 GMT 4/ 8/2024 22: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 19 14.73 382 107 0.11 / 350.20 8 11
2 7 2006.60 40 14.39 2642 1521 1.63 / 351.72 11 14
3 13 1565.88 20 14.40 2148 619 2.25 / 352.34 9 14
4 13 1003.28 20 14.47 1532 443 2.69 / 352.78 10 14
5 13 340.32 20 14.67 710 208 2.90 / 352.99 10 14
6 13 144.60 20 14.73 449 132 3.03 / 353.12 10 14
7 13 32.08 20 14.77 297 88 3.12 / 353.21 10 14
8 8 0.00 285 14.74 254 1067 4.18 / 354.28 10 183
Average= 4.12
(KJ/cycle)

Cycle 84 GMT 30/ 7/2024 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 19 14.72 397 111 0.11 / 346.05 8 11
2 7 2009.28 40 14.38 2647 1523 1.63 / 347.57 11 13
3 13 1553.12 20 14.41 2123 612 2.25 / 348.18 9 14
4 13 955.24 20 14.48 1495 433 2.68 / 348.62 10 14
5 13 311.24 20 14.67 680 200 2.88 / 348.82 10 15
6 13 99.60 20 14.74 401 118 3.00 / 348.93 10 14
7 13 15.00 20 14.77 285 84 3.08 / 349.02 10 14
8 8 0.08 282 14.73 258 1072 4.15 / 350.09 11 206
Average= 4.12
(KJ/cycle)

Cycle 83 GMT 25/ 7/2024 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 19 14.71 399 112 0.11 / 341.89 8 11
2 7 2012.68 40 14.39 2635 1517 1.63 / 343.40 11 13
3 13 1557.20 20 14.41 2141 617 2.25 / 344.02 9 14
4 13 965.52 20 14.48 1515 439 2.68 / 344.46 10 14
5 13 293.92 20 14.67 664 195 2.88 / 344.65 10 15
6 13 51.48 20 14.76 337 99 2.98 / 344.75 10 14
7 8 0.12 304 14.72 265 1186 4.16 / 345.94 10 177
Average= 4.12
(KJ/cycle)

Cycle 82 GMT 20/ 7/2024 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 19 14.72 396 111 0.11 / 337.68 8 11
2 7 2004.88 40 14.39 2638 1518 1.63 / 339.20 11 13
3 13 1588.92 20 14.41 2196 633 2.26 / 339.84 9 14
4 13 966.88 20 14.48 1500 434 2.70 / 340.27 10 15
5 13 365.32 20 14.64 757 222 2.92 / 340.49 10 15
6 13 31.96 20 14.76 311 92 3.01 / 340.58 10 14
7 8 0.04 304 14.72 266 1190 4.20 / 341.77 10 190
Average= 4.12
(KJ/cycle)

Cycle 81 GMT 15/ 7/2024 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 19 14.72 396 111 0.11 / 333.47 8 11
2 7 2015.08 40 14.38 2685 1544 1.66 / 335.02 11 13
3 13 1525.08 20 14.41 2106 607 2.26 / 335.62 9 14
4 13 1008.16 20 14.47 1544 447 2.71 / 336.07 10 14
5 13 334.28 20 14.65 712 209 2.92 / 336.28 10 15
6 13 39.84 20 14.75 326 96 3.01 / 336.37 10 14
7 8 0.08 304 14.72 268 1199 4.21 / 337.57 10 218
Average= 4.12
(KJ/cycle)

Cycle 80 GMT 10/ 7/2024 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 19 14.73 392 110 0.11 / 329.32 8 11
2 7 2003.76 40 14.39 2642 1521 1.63 / 330.84 11 13
3 13 1554.36 20 14.42 2140 617 2.25 / 331.46 9 14
4 13 958.16 20 14.49 1491 432 2.68 / 331.89 10 15
5 13 289.56 20 14.67 654 192 2.87 / 332.08 10 15
6 13 48.32 20 14.76 335 99 2.97 / 332.18 10 14
7 8 0.04 302 14.73 265 1179 4.15 / 333.36 10 174
Average= 4.12
(KJ/cycle)

Cycle 79 GMT 5/ 7/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 19 14.73 390 109 0.11 / 325.16 8 11
2 7 2016.44 40 14.39 2652 1526 1.64 / 326.69 11 13
3 13 1570.16 20 14.41 2155 621 2.26 / 327.31 9 14
4 13 940.08 20 14.49 1474 427 2.68 / 327.74 10 15
5 13 277.80 20 14.68 638 187 2.87 / 327.93 10 15
6 13 36.52 20 14.76 318 94 2.97 / 328.02 10 14
7 8 -0.12 304 14.73 266 1191 4.16 / 329.21 10 229
Average= 4.12
(KJ/cycle)

Cycle 78 GMT 30/ 6/2024 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 19 14.72 395 110 0.11 / 321.03 8 11
2 7 2004.40 40 14.40 2647 1525 1.64 / 322.55 11 13
3 13 1590.00 20 14.42 2181 629 2.26 / 323.18 9 14
4 13 926.44 20 14.50 1459 423 2.69 / 323.60 10 14
5 13 270.24 20 14.68 626 184 2.87 / 323.79 10 15
6 13 29.40 20 14.77 309 91 2.96 / 323.88 10 14
7 8 0.24 304 14.73 263 1178 4.14 / 325.06 10 202
Average= 4.11
(KJ/cycle)

Cycle 77 GMT 25/ 6/2024 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 19 14.71 399 112 0.11 / 316.92 8 11
2 7 2011.28 40 14.40 2646 1524 1.64 / 318.45 11 13
3 13 1483.00 20 14.43 2058 594 2.23 / 319.04 9 14
4 13 929.68 20 14.50 1461 424 2.65 / 319.46 10 15
5 13 227.60 20 14.70 571 168 2.82 / 319.63 10 15
6 13 28.72 20 14.77 310 92 2.91 / 319.72 10 14
7 8 0.12 302 14.72 268 1191 4.10 / 320.92 10 185
Average= 4.11
(KJ/cycle)

Cycle 76 GMT 20/ 6/2024 15:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 19 14.72 397 111 0.11 / 312.80 8 11
2 7 2014.48 40 14.39 2647 1524 1.63 / 314.32 11 13
3 13 1515.60 20 14.43 2101 606 2.24 / 314.93 9 14
4 13 924.00 20 14.50 1448 420 2.66 / 315.35 10 15
5 13 256.36 20 14.69 613 180 2.84 / 315.53 10 15
6 13 31.24 20 14.77 313 92 2.93 / 315.62 10 14
7 8 -0.08 302 14.73 267 1188 4.12 / 316.81 11 197
Average= 4.11
(KJ/cycle)

Cycle 75 GMT 15/ 6/2024 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 19 14.72 396 111 0.11 / 308.67 8 11
2 7 2015.68 40 14.39 2662 1532 1.64 / 310.21 11 13
3 13 1494.56 20 14.44 2066 597 2.24 / 310.80 9 14
4 13 908.00 20 14.50 1444 419 2.66 / 311.22 10 15
5 13 277.08 20 14.68 643 189 2.85 / 311.41 10 15
6 13 30.96 20 14.77 312 92 2.94 / 311.50 10 14
7 8 0.00 302 14.73 267 1188 4.13 / 312.69 10 215
Average= 4.11
(KJ/cycle)

Cycle 74 GMT 10/ 6/2024 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 19 14.73 400 112 0.11 / 304.48 8 11
2 7 2004.08 40 14.40 2654 1529 1.64 / 306.01 11 13
3 13 1558.60 20 14.43 2155 622 2.26 / 306.63 9 14
4 13 966.84 20 14.49 1504 436 2.70 / 307.06 10 15
5 13 331.44 20 14.66 710 208 2.91 / 307.27 10 15
6 13 35.48 20 14.77 318 94 3.00 / 307.37 10 15
7 8 -0.12 302 14.73 269 1197 4.20 / 308.56 10 188
Average= 4.11
(KJ/cycle)

Cycle 73 GMT 5/ 6/2024 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 19 14.74 393 110 0.11 / 300.35 8 11
2 7 2014.72 40 14.39 2670 1537 1.65 / 301.89 11 13
3 13 1526.04 20 14.43 2122 612 2.26 / 302.50 9 14
4 13 925.44 20 14.50 1457 423 2.68 / 302.92 10 15
5 13 227.28 20 14.71 573 169 2.85 / 303.09 10 15
6 13 31.76 20 14.78 314 93 2.94 / 303.18 10 14
7 8 -0.12 300 14.73 268 1184 4.13 / 304.37 10 193
Average= 4.11
(KJ/cycle)

Cycle 72 GMT 31/ 5/2024 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 19 14.74 393 110 0.11 / 296.19 8 11
2 7 2008.64 40 14.41 2634 1518 1.63 / 297.71 11 13
3 13 1556.00 20 14.43 2137 617 2.25 / 298.33 9 14
4 13 941.52 20 14.50 1485 431 2.68 / 298.76 10 14
5 13 278.60 20 14.69 641 188 2.86 / 298.95 10 14
6 13 37.08 20 14.78 319 94 2.96 / 299.04 10 14
7 8 0.08 304 14.74 267 1196 4.15 / 300.24 10 196
Average= 4.11
(KJ/cycle)

Cycle 71 GMT 26/ 5/2024 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 19 14.73 395 111 0.11 / 292.05 8 11
2 7 2015.44 40 14.40 2655 1529 1.64 / 293.58 11 13
3 13 1527.36 20 14.43 2104 607 2.25 / 294.19 9 14
4 13 971.20 20 14.49 1513 438 2.69 / 294.63 10 14
5 13 252.72 20 14.70 604 178 2.86 / 294.81 10 15
6 13 47.24 20 14.77 332 98 2.96 / 294.90 10 14
7 8 -0.08 302 14.74 265 1180 4.14 / 296.08 10 186
Average= 4.11
(KJ/cycle)

Cycle 70 GMT 21/ 5/2024 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 19 14.74 401 112 0.11 / 287.89 8 11
2 7 2003.52 40 14.41 2619 1510 1.62 / 289.40 11 13
3 13 1587.00 20 14.41 2186 630 2.25 / 290.03 9 14
4 13 982.24 20 14.49 1536 445 2.70 / 290.48 10 15
5 13 260.80 20 14.70 622 183 2.88 / 290.66 10 15
6 13 28.36 20 14.79 310 92 2.97 / 290.75 10 14
7 8 0.04 302 14.74 268 1193 4.16 / 291.94 10 209
Average= 4.11
(KJ/cycle)

Cycle 69 GMT 16/ 5/2024 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 19 14.73 396 111 0.11 / 283.72 8 11
2 7 2013.16 40 14.40 2635 1518 1.63 / 285.24 11 13
3 13 1527.08 20 14.44 2094 605 2.23 / 285.84 9 14
4 13 969.04 20 14.50 1522 441 2.67 / 286.29 10 14
5 13 293.40 20 14.69 663 195 2.87 / 286.48 10 15
6 13 41.08 20 14.78 325 96 2.97 / 286.58 10 14
7 8 0.00 302 14.74 270 1202 4.17 / 287.78 10 221
Average= 4.11
(KJ/cycle)

Cycle 68 GMT 11/ 5/2024 10:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 19 14.74 399 112 0.11 / 279.52 8 11
2 7 2004.92 40 14.40 2668 1537 1.65 / 281.06 11 13
3 13 1595.28 20 14.43 2173 627 2.28 / 281.68 9 14
4 13 933.80 20 14.51 1472 427 2.70 / 282.11 10 15
5 13 342.16 20 14.68 721 212 2.91 / 282.32 10 15
6 13 41.00 20 14.78 326 96 3.01 / 282.42 10 14
7 8 -0.04 302 14.74 268 1193 4.20 / 283.61 11 229
Average= 4.11
(KJ/cycle)

Cycle 67 GMT 6/ 5/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 19 14.73 396 111 0.11 / 275.33 8 12
2 7 2011.60 40 14.42 2637 1521 1.63 / 276.85 12 13
3 13 1569.24 20 14.42 2174 627 2.26 / 277.48 9 13
4 13 982.64 20 14.50 1525 442 2.70 / 277.92 10 15
5 13 313.60 20 14.69 688 202 2.90 / 278.12 10 15
6 13 25.12 20 14.79 305 90 2.99 / 278.21 10 14
7 8 -0.08 300 14.74 270 1194 4.19 / 279.41 10 183
Average= 4.11
(KJ/cycle)

Cycle 66 GMT 1/ 5/2024 9:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 19 14.74 398 111 0.11 / 271.15 8 11
2 7 2008.16 40 14.42 2622 1512 1.62 / 272.66 11 13
3 13 1527.84 20 14.45 2101 607 2.23 / 273.27 9 14
4 13 944.40 20 14.51 1487 432 2.66 / 273.70 10 15
5 13 313.00 20 14.69 691 203 2.87 / 273.90 10 15
6 13 55.72 20 14.78 347 103 2.97 / 274.01 10 14
7 8 0.00 304 14.74 271 1214 4.18 / 275.22 10 203
Average= 4.11
(KJ/cycle)

Cycle 65 GMT 26/ 4/2024 8:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 19 14.74 397 111 0.11 / 266.96 8 11
2 7 2009.48 40 14.42 2643 1524 1.64 / 268.48 11 13
3 13 1556.04 20 14.44 2136 617 2.25 / 269.10 9 14
4 13 1005.84 20 14.50 1553 450 2.70 / 269.55 10 14
5 13 327.08 20 14.69 706 207 2.91 / 269.75 10 15
6 13 32.52 20 14.79 314 93 3.00 / 269.85 10 14
7 8 0.08 302 14.75 267 1189 4.19 / 271.04 10 150
Average= 4.11
(KJ/cycle)

Cycle 64 GMT 21/ 4/2024 7:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 19 14.74 400 112 0.11 / 262.80 8 11
2 7 2012.76 40 14.41 2629 1515 1.63 / 264.31 11 13
3 13 1528.52 20 14.44 2132 616 2.24 / 264.93 9 14
4 13 972.40 20 14.51 1513 439 2.68 / 265.37 10 14
5 13 299.40 20 14.70 667 196 2.88 / 265.56 10 15
6 13 44.68 20 14.79 328 97 2.98 / 265.66 10 14
7 8 0.04 302 14.75 266 1185 4.16 / 266.84 10 197
Average= 4.11
(KJ/cycle)

Cycle 63 GMT 16/ 4/2024 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 19 14.74 398 111 0.11 / 258.66 8 11
2 7 2011.68 40 14.42 2617 1509 1.62 / 260.17 11 13
3 13 1553.08 20 14.44 2144 619 2.24 / 260.79 9 14
4 13 921.48 20 14.53 1454 423 2.66 / 261.21 10 14
5 13 293.24 20 14.71 654 192 2.86 / 261.40 10 15
6 13 37.52 20 14.80 317 94 2.95 / 261.49 10 14
7 8 0.04 302 14.75 267 1189 4.14 / 262.68 10 201
Average= 4.10
(KJ/cycle)

Cycle 62 GMT 11/ 4/2024 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 19 14.75 399 112 0.11 / 254.48 8 11
2 7 2012.80 40 14.43 2620 1512 1.62 / 255.99 11 13
3 13 1566.00 20 14.45 2141 619 2.24 / 256.61 9 14
4 13 940.68 20 14.52 1469 427 2.67 / 257.04 10 15
5 13 348.36 20 14.69 731 215 2.88 / 257.25 10 15
6 13 48.48 20 14.79 337 100 2.98 / 257.35 10 14
7 8 -0.04 302 14.75 268 1194 4.18 / 258.55 10 222
Average= 4.10
(KJ/cycle)

Cycle 61 GMT 6/ 4/2024 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 19 14.75 396 111 0.11 / 250.37 8 11
2 7 2006.24 40 14.42 2641 1523 1.63 / 251.89 11 13
3 13 1509.88 20 14.45 2085 603 2.24 / 252.49 9 14
4 13 927.56 20 14.53 1464 425 2.66 / 252.92 10 15
5 13 256.56 20 14.73 608 179 2.84 / 253.10 10 15
6 13 22.28 20 14.81 297 88 2.93 / 253.19 10 14
7 8 0.04 302 14.76 265 1181 4.11 / 254.37 10 197
Average= 4.10
(KJ/cycle)

Cycle 60 GMT 1/ 4/2024 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 19 14.74 395 111 0.11 / 246.25 8 11
2 7 2012.72 40 14.42 2632 1518 1.63 / 247.77 11 13
3 13 1586.32 20 14.45 2161 625 2.25 / 248.40 9 14
4 13 943.56 20 14.53 1487 432 2.69 / 248.83 10 15
5 13 237.80 20 14.74 586 173 2.86 / 249.00 10 15
6 8 0.12 321 14.77 265 1256 4.11 / 250.26 11 201
Average= 4.10
(KJ/cycle)

Cycle 59 GMT 27/ 3/2024 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 19 14.76 397 111 0.11 / 242.13 8 11
2 7 2007.52 40 14.42 2626 1515 1.63 / 243.64 11 13
3 13 1556.40 20 14.45 2136 617 2.24 / 244.26 9 14
4 13 919.52 20 14.54 1454 423 2.67 / 244.68 10 14
5 13 257.20 20 14.73 613 181 2.85 / 244.86 10 15
6 13 20.32 20 14.81 301 89 2.94 / 244.95 10 15
7 8 -0.24 300 14.76 269 1191 4.13 / 246.14 10 170
Average= 4.10
(KJ/cycle)

Cycle 58 GMT 22/ 3/2024 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 19 14.75 398 112 0.11 / 238.04 8 11
2 7 2008.04 40 14.42 2625 1514 1.63 / 239.55 11 13
3 13 1513.08 20 14.46 2081 602 2.23 / 240.15 9 14
4 13 943.92 20 14.53 1487 432 2.66 / 240.59 10 15
5 13 199.76 20 14.75 537 158 2.82 / 240.74 10 15
6 13 21.32 20 14.81 300 89 2.91 / 240.83 10 14
7 8 0.08 300 14.77 267 1183 4.09 / 242.02 11 224
Average= 4.10
(KJ/cycle)

Cycle 57 GMT 17/ 3/2024 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 19 14.75 398 112 0.11 / 233.91 8 11
2 7 2015.12 40 14.43 2630 1518 1.63 / 235.43 11 13
3 13 1495.00 20 14.46 2078 601 2.23 / 236.03 9 13
4 13 974.00 20 14.52 1525 443 2.67 / 236.47 10 15
5 13 264.76 20 14.73 621 183 2.86 / 236.65 10 15
6 13 23.24 20 14.81 302 89 2.95 / 236.74 10 14
7 8 -0.12 300 14.76 267 1182 4.13 / 237.93 10 220
Average= 4.10
(KJ/cycle)

Cycle 56 GMT 12/ 3/2024 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 19 14.76 398 112 0.11 / 229.76 8 11
2 7 2014.24 40 14.43 2636 1521 1.63 / 231.28 11 13
3 13 1519.72 20 14.46 2106 609 2.24 / 231.89 9 14
4 13 955.40 20 14.54 1502 437 2.68 / 232.33 10 14
5 13 275.68 20 14.73 635 187 2.87 / 232.52 10 15
6 13 12.00 20 14.82 286 85 2.95 / 232.60 10 14
7 8 0.08 302 14.77 268 1195 4.15 / 233.80 10 195
Average= 4.10
(KJ/cycle)

Cycle 55 GMT 7/ 3/2024 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 19 14.76 398 112 0.11 / 225.67 8 11
2 7 2007.72 40 14.42 2635 1520 1.63 / 227.19 11 13
3 13 1513.24 20 14.47 2099 607 2.24 / 227.79 9 14
4 13 925.36 20 14.55 1462 425 2.66 / 228.22 10 15
5 13 252.92 20 14.74 607 179 2.84 / 228.40 10 15
6 8 0.00 321 14.78 264 1253 4.10 / 229.65 10 182
Average= 4.10
(KJ/cycle)

Cycle 54 GMT 2/ 3/2024 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 19 14.76 393 110 0.11 / 221.51 8 12
2 7 2009.68 40 14.43 2644 1526 1.64 / 223.04 12 13
3 13 1524.96 20 14.47 2104 609 2.25 / 223.65 9 14
4 13 943.44 20 14.54 1483 431 2.68 / 224.08 10 14
5 13 345.56 20 14.71 729 214 2.89 / 224.29 10 15
6 8 0.16 319 14.78 268 1264 4.15 / 225.56 10 163
Average= 4.10
(KJ/cycle)

Cycle 53 GMT 26/ 2/2024 0: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 19 14.76 400 112 0.11 / 217.30 8 11
2 7 2011.00 40 14.43 2645 1527 1.64 / 218.82 11 13
3 13 1549.16 20 14.47 2144 620 2.26 / 219.44 9 14
4 13 996.48 20 14.53 1550 450 2.71 / 219.89 10 14
5 13 379.08 20 14.70 772 227 2.94 / 220.12 10 15
6 8 0.00 321 14.78 270 1281 4.22 / 221.40 10 207
Average= 4.10
(KJ/cycle)

Cycle 52 GMT 20/ 2/2024 23:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 19 14.78 395 111 0.11 / 213.15 8 11
2 7 2009.20 41 14.42 2651 1567 1.68 / 214.71 11 13
3 13 1565.64 20 14.46 2152 622 2.30 / 215.34 9 14
4 13 855.24 20 14.57 1377 401 2.70 / 215.74 10 15
5 13 271.96 20 14.74 637 188 2.89 / 215.92 10 15
6 8 0.12 319 14.78 267 1259 4.15 / 217.18 10 217
Average= 4.10
(KJ/cycle)

Cycle 51 GMT 15/ 2/2024 23: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 19 14.80 393 111 0.11 / 209.02 8 11
2 7 2009.76 40 14.43 2642 1525 1.64 / 210.55 11 13
3 13 1587.48 20 14.47 2175 629 2.26 / 211.18 9 14
4 13 934.04 20 14.55 1473 429 2.69 / 211.61 10 14
5 13 281.36 20 14.75 638 188 2.88 / 211.79 10 14
6 8 0.20 319 14.80 263 1242 4.12 / 213.04 10 176
Average= 4.10
(KJ/cycle)

Cycle 50 GMT 10/ 2/2024 22:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 19 14.79 401 113 0.11 / 204.86 8 11
2 7 2012.88 40 14.43 2646 1527 1.64 / 206.39 11 13
3 13 1599.08 20 14.46 2182 631 2.27 / 207.02 9 14
4 13 999.80 20 14.54 1545 449 2.72 / 207.47 10 14
5 13 353.48 20 14.73 730 215 2.94 / 207.69 10 14
6 8 0.20 323 14.81 256 1225 4.16 / 208.91 10 198
Average= 4.10
(KJ/cycle)

Cycle 49 GMT 5/ 2/2024 21:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 19 14.80 398 112 0.11 / 200.73 8 11
2 7 2015.16 40 14.43 2651 1530 1.64 / 202.26 11 13
3 13 1520.92 20 14.48 2108 610 2.25 / 202.87 9 14
4 13 967.48 20 14.55 1512 440 2.69 / 203.31 10 14
5 13 291.04 20 14.76 649 192 2.88 / 203.51 10 14
6 8 10.72 321 14.81 262 1246 4.13 / 204.75 10 171
Average= 4.10
(KJ/cycle)

Cycle 48 GMT 31/ 1/2024 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 19 14.81 389 109 0.11 / 196.63 8 11
2 7 2004.68 40 14.43 2661 1536 1.65 / 198.16 11 13
3 13 1477.32 20 14.48 2065 598 2.24 / 198.76 9 14
4 13 935.56 20 14.56 1474 429 2.67 / 199.19 10 14
5 13 296.24 20 14.76 654 193 2.87 / 199.38 10 14
6 13 31.84 20 14.85 300 89 2.95 / 199.47 10 14
7 8 0.16 302 14.81 257 1149 4.10 / 200.62 10 208
Average= 4.09
(KJ/cycle)

Cycle 47 GMT 26/ 1/2024 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 19 14.80 404 114 0.11 / 192.48 8 11
2 7 2007.40 40 14.44 2641 1525 1.64 / 194.00 11 13
3 13 1577.56 20 14.46 2186 632 2.27 / 194.64 9 14
4 13 938.52 20 14.56 1484 432 2.70 / 195.07 10 14
5 13 362.96 20 14.74 747 220 2.92 / 195.29 10 14
6 13 39.64 20 14.85 310 92 3.02 / 195.38 10 14
7 8 0.00 300 14.82 256 1138 4.15 / 196.52 10 192
Average= 4.09
(KJ/cycle)

Cycle 46 GMT 21/ 1/2024 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 19 14.80 393 111 0.11 / 188.28 8 11
2 7 2005.16 41 14.43 2670 1580 1.69 / 189.86 11 13
3 13 1503.08 20 14.49 2090 606 2.30 / 190.47 9 14
4 13 919.80 20 14.58 1454 424 2.72 / 190.89 10 14
5 13 354.96 20 14.74 734 216 2.94 / 191.11 10 14
6 13 65.72 20 14.84 343 102 3.04 / 191.21 10 14
7 8 0.12 300 14.82 260 1156 4.19 / 192.36 10 169
Average= 4.09
(KJ/cycle)

Cycle 45 GMT 16/ 1/2024 18:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 19 14.80 400 112 0.11 / 184.08 8 11
2 7 2015.32 40 14.43 2680 1547 1.66 / 185.63 11 13
3 13 1560.52 20 14.49 2135 619 2.28 / 186.25 9 14
4 13 953.80 20 14.57 1491 434 2.71 / 186.68 10 14
5 13 342.32 20 14.75 718 212 2.92 / 186.89 10 14
6 13 125.40 20 14.82 423 125 3.05 / 187.02 10 14
7 8 0.04 300 14.82 259 1152 4.20 / 188.17 11 160
Average= 4.09
(KJ/cycle)

Cycle 44 GMT 11/ 1/2024 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 19 14.80 395 111 0.11 / 179.95 8 11
2 7 2013.28 40 14.44 2649 1530 1.64 / 181.48 11 13
3 13 1523.28 20 14.50 2096 608 2.25 / 182.09 9 14
4 13 937.60 20 14.57 1481 432 2.68 / 182.52 10 15
5 13 242.40 20 14.78 594 176 2.86 / 182.70 10 14
6 13 51.68 20 14.85 335 99 2.96 / 182.80 10 14
7 8 0.08 300 14.81 264 1173 4.13 / 183.97 10 193
Average= 4.09
(KJ/cycle)

Cycle 43 GMT 6/ 1/2024 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 18 14.81 396 106 0.11 / 175.83 8 11
2 7 2009.20 40 14.45 2627 1518 1.62 / 177.35 11 13
3 13 1545.68 20 14.49 2126 616 2.24 / 177.97 9 14
4 13 944.76 20 14.57 1492 435 2.67 / 178.40 10 15
5 13 272.44 20 14.77 627 185 2.86 / 178.59 10 14
6 8 -0.04 319 14.82 265 1253 4.11 / 179.84 10 166
Average= 4.09
(KJ/cycle)

Cycle 42 GMT 1/ 1/2024 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 18 14.81 397 106 0.11 / 171.69 8 11
2 7 2015.84 40 14.45 2634 1522 1.63 / 173.21 11 13
3 13 1492.36 20 14.50 2075 602 2.23 / 173.81 9 14
4 13 941.88 20 14.58 1490 434 2.66 / 174.24 10 15
5 13 304.08 20 14.77 668 197 2.86 / 174.44 10 14
6 13 63.52 20 14.85 350 104 2.97 / 174.55 10 14
7 8 0.16 302 14.82 264 1182 4.15 / 175.73 10 211
Average= 4.09
(KJ/cycle)

Cycle 41 GMT 27/12/2023 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 18 14.82 404 108 0.11 / 167.50 8 11
2 7 2007.40 41 14.45 2624 1555 1.66 / 169.05 11 13
3 13 1550.48 20 14.50 2131 618 2.28 / 169.67 9 14
4 13 949.68 20 14.58 1501 438 2.72 / 170.11 10 14
5 13 271.16 20 14.79 627 185 2.90 / 170.29 10 14
6 13 112.20 20 14.84 413 123 3.03 / 170.41 10 14
7 8 -0.04 300 14.83 262 1166 4.19 / 171.58 10 158
Average= 4.09
(KJ/cycle)

Cycle 40 GMT 22/12/2023 15:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 18 14.82 406 108 0.11 / 163.37 8 11
2 7 2011.60 40 14.46 2615 1513 1.62 / 164.89 11 13
3 13 1507.40 20 14.50 2105 610 2.23 / 165.50 9 14
4 13 891.80 20 14.60 1429 417 2.65 / 165.91 10 14
5 13 292.84 20 14.78 655 194 2.84 / 166.11 10 14
6 13 89.68 20 14.85 384 114 2.96 / 166.22 10 14
7 8 0.12 300 14.83 262 1166 4.12 / 167.39 10 180
Average= 4.08
(KJ/cycle)

Cycle 39 GMT 17/12/2023 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 18 14.83 381 102 0.10 / 159.23 8 11
2 7 2004.04 40 14.46 2635 1524 1.63 / 160.76 11 13
3 13 1552.36 20 14.50 2135 619 2.24 / 161.38 9 14
4 13 955.28 20 14.58 1499 437 2.68 / 161.81 10 14
5 13 280.80 20 14.79 637 188 2.87 / 162.00 10 14
6 13 90.28 20 14.85 377 112 2.98 / 162.11 10 14
7 8 -0.08 300 14.84 259 1153 4.14 / 163.27 11 165
Average= 4.08
(KJ/cycle)

Cycle 38 GMT 12/12/2023 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 18 14.82 393 105 0.10 / 155.11 8 11
2 7 2005.68 40 14.45 2643 1528 1.63 / 156.64 11 13
3 13 1539.56 20 14.51 2103 610 2.24 / 157.25 9 14
4 13 954.08 20 14.59 1495 436 2.68 / 157.69 10 15
5 13 234.44 20 14.81 577 171 2.85 / 157.86 10 14
6 13 118.16 20 14.85 418 124 2.97 / 157.98 10 14
7 8 0.08 300 14.84 258 1149 4.12 / 159.13 10 213
Average= 4.08
(KJ/cycle)

Cycle 37 GMT 7/12/2023 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 18 14.82 409 109 0.11 / 150.94 8 11
2 7 2004.48 40 14.46 2633 1523 1.63 / 152.46 11 13
3 13 1555.72 20 14.51 2131 618 2.25 / 153.08 9 14
4 13 958.12 20 14.59 1504 439 2.69 / 153.52 10 14
5 13 308.84 20 14.78 678 200 2.89 / 153.72 10 15
6 13 105.64 20 14.85 403 120 3.01 / 153.84 10 14
7 8 0.12 300 14.84 263 1171 4.18 / 155.01 10 181
Average= 4.08
(KJ/cycle)

Cycle 36 GMT 2/12/2023 12:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 18 14.83 388 104 0.10 / 146.73 8 11
2 7 2016.08 40 14.46 2633 1523 1.63 / 148.26 11 13
3 13 1562.20 20 14.50 2142 621 2.25 / 148.88 9 14
4 13 966.88 20 14.59 1515 442 2.69 / 149.32 10 15
5 13 317.28 20 14.78 687 203 2.89 / 149.52 10 14
6 13 111.92 20 14.85 415 123 3.02 / 149.64 10 14
7 8 -0.08 302 14.84 264 1183 4.20 / 150.83 11 199
Average= 4.08
(KJ/cycle)

Cycle 35 GMT 27/11/2023 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 18 14.85 387 103 0.10 / 142.59 8 11
2 7 2006.08 40 14.47 2621 1517 1.62 / 144.11 11 13
3 13 1561.56 20 14.51 2149 624 2.24 / 144.73 9 14
4 13 931.12 20 14.60 1465 428 2.67 / 145.16 10 14
5 13 294.44 20 14.79 656 194 2.87 / 145.35 10 14
6 13 91.32 20 14.86 386 115 2.98 / 145.47 10 14
7 8 0.04 300 14.84 261 1162 4.14 / 146.63 11 156
Average= 4.07
(KJ/cycle)

Cycle 34 GMT 22/11/2023 11:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.56 18 14.84 410 110 0.11 / 138.43 8 11
2 7 2017.00 41 14.47 2649 1572 1.68 / 140.00 11 13
3 13 1496.40 20 14.52 2082 605 2.29 / 140.60 9 14
4 13 942.96 20 14.60 1480 432 2.72 / 141.03 10 15
5 13 296.24 20 14.80 654 194 2.91 / 141.23 10 14
6 13 101.80 20 14.87 392 117 3.03 / 141.34 10 14
7 8 0.20 300 14.86 256 1141 4.17 / 142.49 10 181
Average= 4.07
(KJ/cycle)

Cycle 33 GMT 17/11/2023 10:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 18 14.85 383 102 0.10 / 134.23 8 11
2 7 2013.56 40 14.48 2633 1525 1.63 / 135.76 11 13
3 13 1547.16 20 14.51 2144 622 2.25 / 136.38 9 14
4 13 1021.76 20 14.59 1577 460 2.71 / 136.84 10 15
5 13 295.92 20 14.81 655 194 2.90 / 137.03 10 14
6 13 134.08 20 14.86 436 130 3.03 / 137.16 10 14
7 8 0.00 302 14.86 257 1153 4.19 / 138.32 11 223
Average= 4.07
(KJ/cycle)

Cycle 32 GMT 12/11/2023 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 18 14.85 377 101 0.10 / 130.08 8 11
2 7 2007.68 40 14.47 2638 1527 1.63 / 131.60 11 13
3 13 1544.32 20 14.52 2128 618 2.25 / 132.22 9 14
4 13 943.76 20 14.61 1482 433 2.68 / 132.65 10 14
5 13 332.36 20 14.80 701 207 2.89 / 132.86 10 14
6 13 129.00 20 14.87 426 127 3.01 / 132.99 10 14
7 8 0.24 300 14.87 256 1142 4.15 / 134.13 10 198
Average= 4.06
(KJ/cycle)

Cycle 31 GMT 7/11/2023 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 18 14.86 403 108 0.11 / 125.90 8 11
2 7 2009.60 41 14.47 2647 1570 1.68 / 127.47 11 13
3 13 1511.60 20 14.53 2086 606 2.28 / 128.08 9 14
4 13 921.12 20 14.62 1456 426 2.71 / 128.51 10 15
5 13 282.12 20 14.82 635 188 2.90 / 128.69 10 14
6 13 123.32 20 14.87 425 126 3.02 / 128.82 10 14
7 8 0.00 300 14.87 259 1155 4.18 / 129.98 10 154
Average= 4.06
(KJ/cycle)

Cycle 30 GMT 2/11/2023 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 18 14.87 376 101 0.10 / 121.72 8 11
2 7 2008.20 41 14.47 2648 1571 1.67 / 123.29 11 13
3 13 1544.84 20 14.52 2143 622 2.29 / 123.91 9 14
4 13 912.04 20 14.63 1448 424 2.72 / 124.34 10 14
5 13 307.84 20 14.82 670 199 2.92 / 124.54 10 14
6 13 110.44 20 14.88 406 121 3.04 / 124.66 10 14
7 8 0.12 300 14.87 255 1138 4.17 / 125.79 10 182
Average= 4.06
(KJ/cycle)

Cycle 29 GMT 28/10/2023 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 18 14.87 387 104 0.10 / 117.55 8 11
2 7 2014.12 40 14.47 2653 1536 1.64 / 119.09 11 13
3 13 1525.20 20 14.54 2113 614 2.25 / 119.70 9 14
4 13 974.00 20 14.61 1518 444 2.70 / 120.15 10 14
5 13 332.04 20 14.81 699 207 2.90 / 120.35 10 14
6 13 134.28 20 14.87 434 129 3.03 / 120.48 10 14
7 8 0.16 302 14.88 253 1137 4.17 / 121.62 10 221
Average= 4.05
(KJ/cycle)

Cycle 28 GMT 23/10/2023 7:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 18 14.86 378 101 0.10 / 113.38 8 11
2 7 2012.12 40 14.48 2658 1540 1.64 / 114.92 11 13
3 13 1518.68 20 14.54 2091 608 2.25 / 115.53 9 14
4 13 972.04 20 14.62 1513 442 2.69 / 115.97 10 14
5 13 323.52 20 14.81 694 206 2.90 / 116.18 10 14
6 13 122.84 20 14.88 421 125 3.02 / 116.30 10 14
7 8 0.08 302 14.88 255 1146 4.17 / 117.45 10 226
Average= 4.05
(KJ/cycle)

Cycle 27 GMT 18/10/2023 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 18 14.87 378 101 0.10 / 109.17 8 11
2 7 2004.36 41 14.48 2628 1560 1.66 / 110.73 11 13
3 13 1500.36 20 14.54 2088 607 2.27 / 111.34 9 14
4 13 1005.00 20 14.62 1546 452 2.72 / 111.79 10 14
5 13 342.48 20 14.81 712 211 2.93 / 112.00 10 14
6 13 125.52 20 14.88 427 127 3.06 / 112.13 10 14
7 8 0.28 300 14.88 258 1152 4.21 / 113.28 10 173
Average= 4.05
(KJ/cycle)

Cycle 26 GMT 13/10/2023 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 18 14.88 403 108 0.11 / 105.00 8 11
2 7 2004.76 41 14.48 2642 1569 1.68 / 106.57 11 13
3 13 1500.96 20 14.55 2078 605 2.28 / 107.18 9 14
4 13 938.88 20 14.63 1485 435 2.72 / 107.61 10 14
5 13 321.52 20 14.82 688 204 2.92 / 107.81 10 14
6 13 120.68 20 14.88 419 125 3.04 / 107.94 10 14
7 8 -0.04 300 14.88 254 1134 4.18 / 109.07 10 239
Average= 4.04
(KJ/cycle)

Cycle 25 GMT 8/10/2023 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 18 14.89 404 108 0.11 / 100.85 8 11
2 7 2012.96 40 14.48 2651 1535 1.64 / 102.38 11 13
3 13 1509.04 20 14.55 2093 609 2.25 / 102.99 9 14
4 13 921.92 20 14.64 1461 428 2.68 / 103.42 10 14
5 13 349.36 20 14.81 727 215 2.90 / 103.63 10 14
6 13 110.56 20 14.89 405 121 3.02 / 103.75 10 14
7 8 0.16 300 14.89 255 1139 4.16 / 104.89 11 172
Average= 4.03
(KJ/cycle)

Cycle 24 GMT 3/10/2023 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 18 14.89 378 101 0.10 / 96.69 8 11
2 7 2014.32 40 14.50 2642 1532 1.63 / 98.23 11 13
3 13 1522.76 20 14.55 2116 616 2.25 / 98.84 9 14
4 13 965.80 20 14.64 1488 436 2.69 / 99.28 10 14
5 13 294.40 20 14.84 648 192 2.88 / 99.47 10 14
6 13 135.68 20 14.89 436 130 3.01 / 99.60 10 13
7 8 0.04 302 14.89 253 1138 4.14 / 100.74 11 212
Average= 4.03
(KJ/cycle)

Cycle 23 GMT 28/ 9/2023 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 18 14.89 380 102 0.10 / 92.56 8 11
2 7 2011.08 41 14.50 2641 1570 1.67 / 94.13 11 13
3 13 1476.32 20 14.56 2059 600 2.27 / 94.73 9 14
4 13 917.12 20 14.65 1449 425 2.70 / 95.15 10 14
5 13 271.00 20 14.85 624 185 2.88 / 95.34 10 14
6 13 121.40 20 14.90 419 125 3.01 / 95.46 10 14
7 8 0.12 300 14.90 253 1131 4.14 / 96.59 10 184
Average= 4.02
(KJ/cycle)

Cycle 22 GMT 23/ 9/2023 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 18 14.87 399 107 0.11 / 88.42 8 11
2 7 2005.12 40 14.50 2638 1530 1.64 / 89.95 11 13
3 13 1524.92 20 14.55 2123 618 2.25 / 90.57 9 14
4 13 931.84 20 14.65 1468 430 2.68 / 91.00 10 14
5 13 295.64 20 14.84 657 195 2.88 / 91.20 10 14
6 13 106.20 20 14.91 399 119 3.00 / 91.32 10 14
7 13 18.44 20 14.93 281 84 3.08 / 91.40 10 13
8 8 0.04 278 14.89 255 1056 4.14 / 92.46 10 169
Average= 4.02
(KJ/cycle)

Cycle 21 GMT 18/ 9/2023 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 18 14.86 396 106 0.11 / 84.28 8 11
2 7 2009.60 40 14.51 2658 1543 1.65 / 85.82 11 13
3 13 1499.24 20 14.57 2084 607 2.26 / 86.43 9 14
4 13 883.68 20 14.66 1411 414 2.67 / 86.84 10 15
5 13 248.04 20 14.84 604 179 2.85 / 87.02 10 15
6 13 41.76 20 14.91 335 100 2.95 / 87.12 10 14
7 13 13.96 20 14.92 290 87 3.04 / 87.21 10 14
8 8 0.04 278 14.87 269 1112 4.15 / 88.32 10 188
Average= 4.01
(KJ/cycle)

Cycle 20 GMT 13/ 9/2023 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 18 14.87 396 106 0.11 / 80.14 8 11
2 7 2010.40 40 14.51 2666 1547 1.65 / 81.68 11 13
3 13 1487.76 20 14.57 2084 607 2.26 / 82.29 9 14
4 13 888.24 20 14.66 1417 415 2.68 / 82.71 10 15
5 13 218.24 20 14.85 569 169 2.85 / 82.88 10 15
6 13 29.36 20 14.92 313 93 2.94 / 82.97 10 14
7 13 9.76 20 14.92 287 86 3.02 / 83.05 10 14
8 8 0.04 278 14.87 270 1116 4.14 / 84.17 10 181
Average= 4.01
(KJ/cycle)

Cycle 19 GMT 8/ 9/2023 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 18 14.89 379 102 0.10 / 75.97 8 11
2 7 2004.20 40 14.51 2651 1539 1.64 / 77.51 11 13
3 13 1513.72 20 14.57 2092 610 2.25 / 78.12 9 14
4 13 920.56 20 14.65 1459 427 2.68 / 78.55 10 15
5 13 277.72 20 14.83 647 192 2.87 / 78.74 10 15
6 13 35.80 20 14.91 324 97 2.97 / 78.84 10 14
7 8 0.36 300 14.88 267 1192 4.16 / 80.03 10 202
Average= 4.00
(KJ/cycle)

Cycle 18 GMT 3/ 9/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 18 14.91 371 100 0.10 / 71.81 8 11
2 7 2010.92 40 14.51 2655 1541 1.64 / 73.35 11 13
3 13 1498.60 20 14.58 2067 603 2.24 / 73.95 9 14
4 13 965.60 20 14.65 1508 442 2.69 / 74.39 10 14
5 13 311.04 20 14.84 681 202 2.89 / 74.59 10 14
6 13 100.28 20 14.91 397 118 3.01 / 74.71 10 14
7 13 15.52 20 14.94 280 84 3.09 / 74.80 10 14
8 8 0.16 280 14.90 258 1076 4.17 / 75.87 10 183
Average= 3.99
(KJ/cycle)

Cycle 17 GMT 29/ 8/2023 0: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 18 14.90 376 101 0.10 / 67.73 8 11
2 7 2015.40 40 14.52 2655 1542 1.64 / 69.27 11 13
3 13 1450.36 20 14.59 2028 592 2.23 / 69.86 9 14
4 13 941.16 20 14.66 1476 433 2.67 / 70.30 10 14
5 13 232.28 20 14.88 565 168 2.84 / 70.46 10 14
6 13 119.32 20 14.92 412 123 2.96 / 70.59 10 14
7 13 22.28 20 14.95 279 83 3.04 / 70.67 10 13
8 8 -0.08 278 14.91 250 1036 4.08 / 71.71 10 157
Average= 3.98
(KJ/cycle)

Cycle 16 GMT 23/ 8/2023 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 18 14.90 379 102 0.10 / 63.53 8 11
2 7 2013.72 40 14.53 2624 1525 1.63 / 65.06 11 13
3 13 1527.80 20 14.58 2108 615 2.24 / 65.67 9 14
4 13 1042.08 20 14.64 1597 468 2.71 / 66.14 10 14
5 13 347.48 20 14.84 724 215 2.92 / 66.36 10 14
6 13 102.36 20 14.92 392 117 3.04 / 66.47 10 14
7 13 16.88 20 14.95 279 83 3.12 / 66.56 10 13
8 8 0.08 282 14.91 255 1072 4.20 / 67.63 10 226
Average= 3.98
(KJ/cycle)

Cycle 15 GMT 18/ 8/2023 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 18 14.92 374 100 0.10 / 59.37 8 11
2 7 2008.20 40 14.52 2667 1549 1.65 / 60.92 11 13
3 13 1546.96 20 14.58 2134 622 2.27 / 61.54 9 14
4 13 951.68 20 14.66 1486 436 2.71 / 61.98 10 14
5 13 266.44 20 14.87 616 183 2.89 / 62.16 10 14
6 13 107.96 20 14.92 398 119 3.01 / 62.28 10 14
7 13 16.76 20 14.95 276 83 3.09 / 62.36 10 14
8 8 0.04 282 14.91 254 1068 4.16 / 63.43 10 204
Average= 3.96
(KJ/cycle)

Cycle 14 GMT 13/ 8/2023 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 18 14.91 372 100 0.10 / 55.26 8 11
2 7 2014.04 40 14.52 2659 1544 1.64 / 56.81 11 13
3 13 1509.72 20 14.59 2092 610 2.25 / 57.42 9 14
4 13 922.20 20 14.68 1457 428 2.68 / 57.84 10 14
5 13 271.08 20 14.88 616 183 2.87 / 58.03 10 14
6 13 113.44 20 14.92 405 121 2.99 / 58.15 10 14
7 8 0.12 300 14.92 251 1123 4.11 / 59.27 10 156
Average= 3.95
(KJ/cycle)

Cycle 13 GMT 8/ 8/2023 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 18 14.91 374 100 0.10 / 51.11 8 11
2 7 2003.56 40 14.53 2665 1549 1.65 / 52.66 11 13
3 13 1538.64 20 14.59 2129 621 2.27 / 53.28 9 14
4 13 941.88 20 14.68 1478 434 2.70 / 53.72 10 15
5 13 257.68 20 14.88 602 179 2.88 / 53.90 10 14
6 13 97.44 20 14.93 385 115 3.00 / 54.01 10 14
7 13 14.56 20 14.96 277 83 3.08 / 54.09 10 14
8 8 0.12 280 14.92 256 1069 4.15 / 55.16 10 180
Average= 3.94
(KJ/cycle)

Cycle 12 GMT 3/ 8/2023 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 18 14.91 379 102 0.10 / 46.96 8 11
2 7 2003.72 40 14.54 2640 1535 1.64 / 48.50 11 13
3 13 1545.76 20 14.60 2123 620 2.26 / 49.12 9 14
4 13 946.08 20 14.67 1481 435 2.69 / 49.55 10 14
5 13 269.16 20 14.87 626 186 2.88 / 49.74 10 14
6 13 75.76 20 14.94 360 108 2.99 / 49.85 10 14
7 13 19.84 20 14.96 285 85 3.07 / 49.93 10 14
8 8 0.12 280 14.92 258 1078 4.15 / 51.01 10 163
Average= 3.92
(KJ/cycle)

Cycle 11 GMT 29/ 7/2023 20: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 18 14.92 378 102 0.10 / 42.81 8 11
2 7 2014.12 41 14.54 2640 1574 1.68 / 44.39 11 13
3 13 1504.44 20 14.60 2083 608 2.28 / 45.00 9 14
4 13 940.96 20 14.68 1482 435 2.72 / 45.43 10 14
5 13 249.20 20 14.89 592 176 2.89 / 45.61 10 14
6 13 85.52 20 14.94 371 111 3.01 / 45.72 10 14
7 8 0.20 300 14.92 256 1146 4.15 / 46.86 10 181
Average= 3.91
(KJ/cycle)

Cycle 10 GMT 24/ 7/2023 19:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 18 14.92 376 101 0.10 / 38.71 8 11
2 7 2008.68 40 14.55 2630 1531 1.63 / 40.24 11 13
3 13 1510.76 20 14.61 2080 608 2.24 / 40.85 9 14
4 13 917.72 20 14.69 1454 427 2.67 / 41.28 10 15
5 13 277.08 20 14.88 629 187 2.85 / 41.46 10 14
6 13 120.72 20 14.93 412 123 2.98 / 41.59 10 14
7 8 0.20 300 14.93 251 1124 4.10 / 42.71 10 185
Average= 3.88
(KJ/cycle)

Cycle 9 GMT 19/ 7/2023 18:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 18 14.92 383 103 0.10 / 34.63 8 11
2 7 2004.20 40 14.55 2625 1528 1.63 / 36.16 11 13
3 13 1503.28 20 14.61 2072 605 2.24 / 36.77 9 14
4 13 866.64 20 14.70 1391 409 2.65 / 37.18 10 15
5 13 238.04 20 14.90 575 171 2.82 / 37.35 10 14
6 13 123.52 20 14.93 421 126 2.94 / 37.47 10 14
7 8 0.20 300 14.93 254 1138 4.08 / 38.61 10 215
Average= 3.86
(KJ/cycle)

Cycle 8 GMT 14/ 7/2023 17:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 18 14.93 374 101 0.10 / 30.51 8 11
2 7 2009.48 40 14.55 2640 1536 1.64 / 32.05 11 13
3 13 1479.92 20 14.61 2056 601 2.24 / 32.65 9 14
4 13 926.24 20 14.69 1463 430 2.67 / 33.08 10 15
5 13 283.92 20 14.88 636 189 2.86 / 33.27 10 14
6 13 127.16 20 14.93 423 126 2.98 / 33.39 10 14
7 8 0.08 300 14.93 254 1138 4.12 / 34.53 10 163
Average= 3.84
(KJ/cycle)

Cycle 7 GMT 9/ 7/2023 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 18 14.92 368 99 0.10 / 26.40 8 11
2 7 2005.40 40 14.55 2630 1531 1.63 / 27.93 11 13
3 13 1509.28 20 14.61 2073 606 2.24 / 28.54 9 14
4 13 875.20 20 14.70 1401 412 2.65 / 28.95 9 14
5 13 305.92 20 14.88 664 198 2.84 / 29.15 10 14
6 13 140.76 20 14.93 439 131 2.98 / 29.28 10 14
7 8 0.16 300 14.94 252 1129 4.11 / 30.41 10 218
Average= 3.80
(KJ/cycle)

Cycle 6 GMT 4/ 7/2023 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 17 14.93 373 95 0.09 / 22.24 8 11
2 3 1521.52 1 14.76 2146 32 0.13 / 22.27 9 13
3 7 2005.68 40 14.56 2638 1536 1.66 / 23.81 13 13
4 13 1513.44 20 14.62 2076 607 2.27 / 24.42 9 14
5 13 957.48 20 14.68 1499 440 2.71 / 24.86 9 14
6 13 308.04 20 14.88 664 198 2.91 / 25.05 10 14
7 13 142.28 20 14.93 437 130 3.04 / 25.18 10 14
8 13 12.00 20 14.98 265 79 3.12 / 25.26 10 13
9 8 0.08 282 14.94 247 1041 4.16 / 26.30 10 192
Average= 3.76
(KJ/cycle)

Cycle 5 GMT 29/ 6/2023 16: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 17 14.90 392 99 0.10 / 18.10 8 11
2 7 2006.04 41 14.55 2664 1589 1.69 / 19.69 11 13
3 13 1459.56 20 14.63 2021 591 2.28 / 20.28 9 14
4 13 891.08 20 14.71 1411 415 2.69 / 20.69 9 14
5 13 306.16 20 14.88 666 198 2.89 / 20.89 10 14
6 13 137.48 20 14.94 436 130 3.02 / 21.02 10 14
7 8 0.08 300 14.94 251 1125 4.15 / 22.15 10 163
Average= 3.69
(KJ/cycle)

Cycle 4 GMT 24/ 6/2023 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 17 14.92 388 98 0.10 / 14.00 8 11
2 7 2009.16 40 14.56 2643 1539 1.64 / 15.53 11 13
3 13 1481.60 20 14.63 2040 597 2.23 / 16.13 9 14
4 13 889.36 20 14.71 1411 415 2.65 / 16.55 9 14
5 13 271.56 20 14.88 627 187 2.84 / 16.73 10 14
6 13 32.40 20 14.96 309 92 2.93 / 16.83 10 14
7 8 8.04 300 14.92 262 1173 4.10 / 18.00 10 179
Average= 3.60
(KJ/cycle)

Cycle 3 GMT 19/ 6/2023 14:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 17 14.93 369 94 0.09 / 9.90 8 11
2 7 2009.64 40 14.58 2598 1515 1.61 / 11.42 11 13
3 13 1585.80 20 14.62 2150 629 2.24 / 12.04 9 14
4 13 943.84 20 14.70 1477 434 2.67 / 12.48 9 14
5 13 263.44 20 14.89 612 182 2.85 / 12.66 10 14
6 13 66.04 20 14.95 345 103 2.96 / 12.76 10 14
7 8 0.12 300 14.93 253 1133 4.09 / 13.90 10 205
Average= 3.47
(KJ/cycle)

Cycle 2 GMT 14/ 6/2023 13:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 17 14.90 367 93 0.09 / 5.82 8 11
2 3 1530.20 1 14.76 2164 32 0.12 / 5.85 9 13
3 7 2013.40 40 14.57 2631 1533 1.66 / 7.38 13 13
4 13 1501.00 20 14.64 2041 598 2.26 / 7.98 9 14
5 13 918.36 20 14.71 1444 425 2.68 / 8.40 9 14
6 13 284.72 20 14.90 621 185 2.87 / 8.59 10 14
7 13 132.72 20 14.94 419 125 2.99 / 8.71 10 13
8 8 0.20 302 14.95 242 1093 4.08 / 9.81 10 171
Average= 3.27
(KJ/cycle)

Cycle 1 GMT 9/ 6/2023 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 18 15.08 356 97 0.10 / 1.74 8 11
2 3 1431.52 -1 15.32 6 0 0.00 / 1.74 8 11
3 7 2012.44 40 14.57 2619 1526 1.62 / 3.27 11 13
4 13 1533.76 20 14.62 2091 611 2.23 / 3.88 9 14
5 13 940.28 20 14.69 1466 431 2.67 / 4.31 9 14
6 13 286.04 20 14.88 627 187 2.85 / 4.50 10 14
7 13 136.00 20 14.92 425 127 2.98 / 4.62 10 13
8 8 0.16 302 14.92 244 1099 4.08 / 5.72 10 185
Average= 2.86
(KJ/cycle)

Cycle 0 GMT 4/ 6/2023 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 18 15.22 393 108 0.11 / 0.11 9 12
2 7 132.52 40 15.20 404 246 0.35 / 0.35 12 13
3 13 160.44 20 15.18 436 132 0.49 / 0.49 10 13
4 13 134.08 20 15.17 400 121 0.61 / 0.61 10 13
5 8 -0.04 302 15.14 227 1038 1.64 / 1.64 11 224
Average= 1.64
(KJ/cycle)