SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 17 | 15.04 | 477 | 122 | 0.12 / 493.36 | 5 | 5 |
2 | 7 | 2009.96 | 41 | 14.65 | 3447 | 2070 | 2.19 / 495.43 | 5 | 12 |
3 | 13 | 1442.48 | 20 | 14.72 | 2612 | 769 | 2.96 / 496.20 | 4 | 19 |
4 | 13 | 779.20 | 20 | 14.85 | 1612 | 479 | 3.44 / 496.68 | 5 | 25 |
5 | 13 | 105.72 | 20 | 15.06 | 522 | 157 | 3.60 / 496.84 | 5 | 23 |
6 | 13 | 30.20 | 20 | 15.07 | 401 | 121 | 3.72 / 496.96 | 5 | 22 |
7 | 8 | 0.00 | 225 | 15.03 | 340 | 1150 | 4.87 / 498.11 | 5 | 140 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 17 | 15.02 | 496 | 127 | 0.13 / 488.54 | 5 | 5 |
2 | 7 | 2008.60 | 40 | 14.65 | 3470 | 2033 | 2.16 / 490.57 | 5 | 16 |
3 | 13 | 1484.40 | 20 | 14.72 | 2677 | 788 | 2.95 / 491.36 | 5 | 18 |
4 | 13 | 787.84 | 20 | 14.84 | 1630 | 484 | 3.43 / 491.84 | 5 | 27 |
5 | 13 | 79.28 | 20 | 15.06 | 475 | 143 | 3.58 / 491.99 | 5 | 25 |
6 | 13 | 23.48 | 20 | 15.07 | 392 | 118 | 3.69 / 492.11 | 5 | 26 |
7 | 8 | -0.16 | 223 | 15.03 | 338 | 1133 | 4.83 / 493.24 | 5 | 134 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 17 | 15.05 | 489 | 125 | 0.13 / 483.68 | 5 | 5 |
2 | 7 | 2012.80 | 41 | 14.64 | 3475 | 2086 | 2.21 / 485.77 | 5 | 15 |
3 | 13 | 1343.80 | 20 | 14.73 | 2467 | 727 | 2.94 / 486.49 | 4 | 19 |
4 | 13 | 772.84 | 20 | 14.84 | 1617 | 480 | 3.42 / 486.97 | 4 | 29 |
5 | 13 | 83.20 | 20 | 15.06 | 501 | 151 | 3.57 / 487.12 | 5 | 26 |
6 | 13 | 22.20 | 20 | 15.07 | 396 | 119 | 3.69 / 487.24 | 5 | 27 |
7 | 8 | -0.12 | 223 | 15.02 | 349 | 1169 | 4.86 / 488.41 | 5 | 136 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 17 | 15.03 | 505 | 129 | 0.13 / 478.92 | 5 | 5 |
2 | 7 | 2004.84 | 41 | 14.65 | 3460 | 2078 | 2.21 / 480.99 | 5 | 17 |
3 | 13 | 1334.68 | 20 | 14.75 | 2441 | 720 | 2.93 / 481.71 | 4 | 19 |
4 | 13 | 718.52 | 20 | 14.87 | 1501 | 446 | 3.37 / 482.16 | 5 | 27 |
5 | 13 | 80.92 | 20 | 15.07 | 465 | 140 | 3.51 / 482.30 | 5 | 25 |
6 | 13 | 21.64 | 20 | 15.08 | 361 | 109 | 3.62 / 482.41 | 5 | 24 |
7 | 8 | -0.04 | 223 | 15.03 | 342 | 1146 | 4.77 / 483.56 | 5 | 138 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 17 | 15.03 | 501 | 128 | 0.13 / 474.11 | 5 | 5 |
2 | 7 | 2008.92 | 40 | 14.66 | 3455 | 2026 | 2.15 / 476.13 | 5 | 17 |
3 | 13 | 1423.28 | 20 | 14.73 | 2582 | 761 | 2.91 / 476.89 | 4 | 22 |
4 | 13 | 770.44 | 20 | 14.86 | 1581 | 470 | 3.38 / 477.36 | 4 | 26 |
5 | 13 | 102.04 | 20 | 15.06 | 503 | 152 | 3.54 / 477.52 | 5 | 26 |
6 | 13 | 29.88 | 20 | 15.08 | 374 | 113 | 3.65 / 477.63 | 5 | 26 |
7 | 8 | -0.08 | 223 | 15.02 | 346 | 1159 | 4.81 / 478.79 | 5 | 135 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 17 | 15.04 | 507 | 130 | 0.13 / 469.32 | 5 | 5 |
2 | 7 | 2014.40 | 40 | 14.65 | 3467 | 2032 | 2.16 / 471.35 | 5 | 14 |
3 | 13 | 1369.08 | 20 | 14.74 | 2485 | 733 | 2.89 / 472.09 | 4 | 21 |
4 | 13 | 721.72 | 20 | 14.87 | 1510 | 449 | 3.34 / 472.53 | 5 | 28 |
5 | 13 | 87.32 | 20 | 15.07 | 478 | 144 | 3.49 / 472.68 | 5 | 27 |
6 | 13 | 25.36 | 20 | 15.07 | 404 | 122 | 3.61 / 472.80 | 5 | 26 |
7 | 8 | -0.08 | 223 | 15.02 | 352 | 1179 | 4.79 / 473.98 | 5 | 138 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 17 | 15.04 | 506 | 129 | 0.13 / 464.58 | 5 | 5 |
2 | 7 | 2004.00 | 41 | 14.66 | 3439 | 2067 | 2.20 / 466.64 | 5 | 15 |
3 | 13 | 1289.72 | 20 | 14.76 | 2368 | 699 | 2.90 / 467.34 | 5 | 22 |
4 | 13 | 654.84 | 20 | 14.89 | 1403 | 418 | 3.31 / 467.76 | 5 | 26 |
5 | 13 | 67.92 | 20 | 15.07 | 473 | 143 | 3.46 / 467.90 | 5 | 24 |
6 | 13 | 16.08 | 20 | 15.08 | 386 | 116 | 3.57 / 468.02 | 5 | 24 |
7 | 8 | 0.04 | 223 | 15.03 | 350 | 1173 | 4.75 / 469.19 | 5 | 133 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 17 | 15.04 | 505 | 129 | 0.13 / 459.74 | 5 | 5 |
2 | 7 | 2004.44 | 41 | 14.65 | 3474 | 2087 | 2.22 / 461.82 | 5 | 16 |
3 | 13 | 1374.24 | 20 | 14.74 | 2527 | 745 | 2.96 / 462.57 | 4 | 22 |
4 | 13 | 694.32 | 20 | 14.87 | 1490 | 443 | 3.40 / 463.01 | 4 | 27 |
5 | 13 | 70.60 | 20 | 15.07 | 479 | 144 | 3.55 / 463.16 | 5 | 23 |
6 | 13 | 20.80 | 20 | 15.07 | 391 | 118 | 3.67 / 463.27 | 5 | 24 |
7 | 8 | 0.04 | 223 | 15.03 | 350 | 1173 | 4.84 / 464.45 | 5 | 138 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 17 | 15.05 | 497 | 127 | 0.13 / 454.89 | 5 | 5 |
2 | 7 | 2013.32 | 40 | 14.65 | 3474 | 2036 | 2.16 / 456.93 | 5 | 20 |
3 | 13 | 1415.44 | 20 | 14.73 | 2578 | 759 | 2.92 / 457.69 | 4 | 23 |
4 | 13 | 733.84 | 20 | 14.87 | 1546 | 460 | 3.38 / 458.15 | 4 | 26 |
5 | 13 | 77.60 | 20 | 15.07 | 499 | 150 | 3.53 / 458.30 | 5 | 25 |
6 | 13 | 27.52 | 20 | 15.08 | 407 | 123 | 3.66 / 458.42 | 5 | 24 |
7 | 8 | -0.04 | 225 | 15.03 | 351 | 1187 | 4.84 / 459.61 | 5 | 146 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 17 | 15.04 | 511 | 131 | 0.13 / 450.06 | 5 | 5 |
2 | 7 | 2014.44 | 40 | 14.66 | 3483 | 2042 | 2.17 / 452.10 | 5 | 15 |
3 | 13 | 1422.88 | 20 | 14.73 | 2583 | 761 | 2.93 / 452.86 | 4 | 17 |
4 | 13 | 766.00 | 20 | 14.86 | 1591 | 473 | 3.41 / 453.33 | 4 | 25 |
5 | 13 | 67.56 | 20 | 15.08 | 462 | 139 | 3.55 / 453.47 | 5 | 25 |
6 | 13 | 21.84 | 20 | 15.08 | 393 | 119 | 3.66 / 453.59 | 5 | 21 |
7 | 8 | -0.08 | 225 | 15.03 | 347 | 1173 | 4.84 / 454.76 | 5 | 142 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 17 | 15.05 | 495 | 127 | 0.13 / 445.20 | 5 | 5 |
2 | 7 | 2012.88 | 40 | 14.66 | 3466 | 2032 | 2.16 / 447.23 | 5 | 9 |
3 | 13 | 1401.24 | 20 | 14.74 | 2563 | 756 | 2.91 / 447.98 | 4 | 19 |
4 | 13 | 745.72 | 20 | 14.87 | 1570 | 467 | 3.38 / 448.45 | 4 | 25 |
5 | 13 | 110.28 | 20 | 15.06 | 537 | 162 | 3.54 / 448.61 | 5 | 28 |
6 | 13 | 34.96 | 20 | 15.07 | 421 | 127 | 3.67 / 448.74 | 5 | 25 |
7 | 8 | -0.12 | 225 | 15.03 | 351 | 1187 | 4.86 / 449.93 | 5 | 145 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 17 | 15.05 | 493 | 126 | 0.13 / 440.36 | 5 | 5 |
2 | 7 | 2013.40 | 40 | 14.66 | 3458 | 2028 | 2.15 / 442.39 | 5 | 15 |
3 | 13 | 1418.64 | 20 | 14.74 | 2560 | 755 | 2.91 / 443.14 | 5 | 20 |
4 | 13 | 771.28 | 20 | 14.86 | 1587 | 472 | 3.38 / 443.62 | 5 | 26 |
5 | 13 | 97.52 | 20 | 15.06 | 517 | 156 | 3.54 / 443.77 | 5 | 25 |
6 | 13 | 31.32 | 20 | 15.08 | 410 | 124 | 3.66 / 443.90 | 5 | 25 |
7 | 8 | 0.00 | 225 | 15.03 | 347 | 1173 | 4.83 / 445.07 | 5 | 151 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 17 | 15.05 | 498 | 127 | 0.13 / 435.62 | 5 | 5 |
2 | 7 | 2005.76 | 40 | 14.66 | 3450 | 2023 | 2.15 / 437.64 | 5 | 14 |
3 | 13 | 1353.24 | 20 | 14.75 | 2470 | 729 | 2.88 / 438.37 | 5 | 19 |
4 | 13 | 751.92 | 20 | 14.87 | 1551 | 461 | 3.34 / 438.83 | 5 | 26 |
5 | 13 | 88.24 | 20 | 15.07 | 474 | 143 | 3.48 / 438.97 | 5 | 23 |
6 | 13 | 31.80 | 20 | 15.08 | 376 | 113 | 3.60 / 439.09 | 5 | 23 |
7 | 8 | 0.00 | 225 | 15.04 | 340 | 1151 | 4.75 / 440.24 | 5 | 148 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 17 | 15.05 | 506 | 129 | 0.13 / 430.82 | 5 | 5 |
2 | 7 | 2008.88 | 40 | 14.66 | 3477 | 2039 | 2.17 / 432.86 | 5 | 14 |
3 | 13 | 1375.32 | 20 | 14.73 | 2542 | 749 | 2.92 / 433.61 | 4 | 18 |
4 | 13 | 691.72 | 20 | 14.88 | 1489 | 443 | 3.36 / 434.05 | 4 | 26 |
5 | 13 | 103.16 | 20 | 15.07 | 510 | 154 | 3.51 / 434.20 | 5 | 24 |
6 | 13 | 31.44 | 20 | 15.08 | 399 | 120 | 3.63 / 434.32 | 5 | 22 |
7 | 8 | -0.04 | 225 | 15.04 | 344 | 1164 | 4.80 / 435.49 | 5 | 150 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 17 | 15.06 | 502 | 129 | 0.13 / 425.99 | 5 | 5 |
2 | 7 | 2005.36 | 41 | 14.65 | 3487 | 2094 | 2.22 / 428.08 | 5 | 17 |
3 | 13 | 1321.60 | 20 | 14.76 | 2437 | 719 | 2.94 / 428.80 | 5 | 21 |
4 | 13 | 723.52 | 20 | 14.87 | 1540 | 458 | 3.40 / 429.26 | 4 | 26 |
5 | 13 | 98.16 | 20 | 15.07 | 518 | 156 | 3.56 / 429.41 | 5 | 20 |
6 | 13 | 30.00 | 20 | 15.09 | 403 | 122 | 3.68 / 429.54 | 5 | 17 |
7 | 8 | 0.04 | 223 | 15.04 | 344 | 1154 | 4.83 / 430.69 | 5 | 132 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 17 | 15.06 | 503 | 129 | 0.13 / 421.16 | 5 | 5 |
2 | 7 | 2003.52 | 40 | 14.67 | 3466 | 2034 | 2.16 / 423.19 | 5 | 14 |
3 | 13 | 1402.36 | 20 | 14.74 | 2567 | 757 | 2.92 / 423.95 | 4 | 17 |
4 | 13 | 762.96 | 20 | 14.87 | 1596 | 475 | 3.39 / 424.42 | 5 | 27 |
5 | 13 | 132.44 | 20 | 15.07 | 561 | 169 | 3.56 / 424.59 | 5 | 22 |
6 | 13 | 31.32 | 20 | 15.09 | 399 | 120 | 3.68 / 424.71 | 5 | 19 |
7 | 8 | 0.08 | 225 | 15.05 | 338 | 1145 | 4.83 / 425.86 | 5 | 138 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 17 | 15.05 | 516 | 132 | 0.13 / 416.26 | 5 | 5 |
2 | 7 | 2005.16 | 41 | 14.66 | 3469 | 2085 | 2.22 / 418.35 | 5 | 18 |
3 | 13 | 1375.12 | 20 | 14.74 | 2533 | 747 | 2.96 / 419.09 | 4 | 21 |
4 | 13 | 762.52 | 20 | 14.87 | 1611 | 479 | 3.44 / 419.57 | 5 | 24 |
5 | 13 | 160.40 | 20 | 15.05 | 625 | 188 | 3.63 / 419.76 | 5 | 24 |
6 | 13 | 20.40 | 20 | 15.09 | 389 | 117 | 3.75 / 419.88 | 5 | 20 |
7 | 8 | 0.00 | 225 | 15.05 | 340 | 1151 | 4.90 / 421.03 | 5 | 147 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 17 | 15.05 | 516 | 132 | 0.13 / 411.36 | 5 | 5 |
2 | 7 | 2010.96 | 40 | 14.66 | 3458 | 2028 | 2.16 / 413.39 | 5 | 15 |
3 | 13 | 1455.40 | 20 | 14.74 | 2621 | 773 | 2.93 / 414.16 | 4 | 18 |
4 | 13 | 800.24 | 20 | 14.86 | 1658 | 493 | 3.43 / 414.65 | 4 | 23 |
5 | 13 | 116.72 | 20 | 15.07 | 556 | 168 | 3.59 / 414.82 | 5 | 23 |
6 | 13 | 26.48 | 20 | 15.09 | 400 | 121 | 3.71 / 414.94 | 5 | 21 |
7 | 8 | 0.08 | 225 | 15.04 | 351 | 1188 | 4.90 / 416.13 | 5 | 136 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 17 | 15.05 | 509 | 130 | 0.13 / 406.47 | 5 | 5 |
2 | 7 | 2008.56 | 40 | 14.67 | 3483 | 2044 | 2.17 / 408.51 | 5 | 19 |
3 | 13 | 1411.12 | 20 | 14.75 | 2554 | 753 | 2.93 / 409.27 | 4 | 17 |
4 | 13 | 764.56 | 20 | 14.87 | 1609 | 479 | 3.41 / 409.75 | 4 | 25 |
5 | 13 | 100.48 | 20 | 15.07 | 538 | 162 | 3.57 / 409.91 | 5 | 20 |
6 | 13 | 33.44 | 20 | 15.09 | 417 | 126 | 3.69 / 410.03 | 5 | 25 |
7 | 8 | -0.04 | 225 | 15.04 | 353 | 1195 | 4.89 / 411.23 | 5 | 134 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 17 | 15.05 | 525 | 134 | 0.13 / 401.58 | 5 | 5 |
2 | 7 | 2014.24 | 41 | 14.67 | 3474 | 2090 | 2.22 / 403.67 | 5 | 17 |
3 | 13 | 1404.36 | 20 | 14.75 | 2560 | 755 | 2.98 / 404.43 | 4 | 19 |
4 | 13 | 715.76 | 20 | 14.89 | 1529 | 455 | 3.43 / 404.88 | 4 | 25 |
5 | 13 | 87.68 | 20 | 15.08 | 505 | 152 | 3.59 / 405.03 | 5 | 21 |
6 | 13 | 27.92 | 20 | 15.10 | 410 | 124 | 3.71 / 405.16 | 5 | 20 |
7 | 8 | 0.00 | 225 | 15.05 | 349 | 1182 | 4.89 / 406.34 | 5 | 147 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 17 | 15.06 | 510 | 131 | 0.13 / 396.79 | 5 | 5 |
2 | 7 | 2010.20 | 40 | 14.67 | 3455 | 2027 | 2.16 / 398.82 | 5 | 14 |
3 | 13 | 1380.12 | 20 | 14.76 | 2509 | 741 | 2.90 / 399.56 | 4 | 17 |
4 | 13 | 730.72 | 20 | 14.89 | 1522 | 453 | 3.35 / 400.01 | 4 | 26 |
5 | 13 | 132.84 | 20 | 15.08 | 541 | 163 | 3.52 / 400.18 | 5 | 20 |
6 | 13 | 23.64 | 20 | 15.10 | 383 | 116 | 3.63 / 400.29 | 5 | 20 |
7 | 8 | -0.04 | 225 | 15.05 | 341 | 1155 | 4.79 / 401.45 | 5 | 140 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 17 | 15.07 | 511 | 131 | 0.13 / 391.96 | 5 | 5 |
2 | 7 | 2004.92 | 40 | 14.67 | 3474 | 2039 | 2.17 / 394.00 | 5 | 12 |
3 | 13 | 1341.20 | 20 | 14.76 | 2473 | 730 | 2.90 / 394.73 | 4 | 21 |
4 | 13 | 737.28 | 20 | 14.89 | 1553 | 462 | 3.36 / 395.19 | 5 | 26 |
5 | 13 | 141.36 | 20 | 15.07 | 589 | 178 | 3.54 / 395.37 | 5 | 21 |
6 | 13 | 13.04 | 20 | 15.11 | 375 | 113 | 3.65 / 395.48 | 5 | 18 |
7 | 8 | 0.04 | 225 | 15.05 | 349 | 1182 | 4.83 / 396.66 | 5 | 147 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 17 | 15.07 | 500 | 128 | 0.13 / 387.08 | 5 | 5 |
2 | 7 | 2013.64 | 40 | 14.68 | 3487 | 2048 | 2.18 / 389.13 | 5 | 11 |
3 | 13 | 1426.44 | 20 | 14.74 | 2611 | 770 | 2.95 / 389.90 | 4 | 21 |
4 | 13 | 740.84 | 20 | 14.89 | 1565 | 466 | 3.41 / 390.37 | 5 | 27 |
5 | 13 | 156.00 | 20 | 15.07 | 613 | 185 | 3.60 / 390.55 | 5 | 20 |
6 | 13 | 16.40 | 20 | 15.11 | 374 | 113 | 3.71 / 390.67 | 5 | 17 |
7 | 8 | 0.00 | 225 | 15.06 | 343 | 1162 | 4.87 / 391.83 | 5 | 129 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 17 | 15.07 | 514 | 132 | 0.13 / 382.27 | 5 | 5 |
2 | 7 | 2010.76 | 40 | 14.68 | 3459 | 2031 | 2.16 / 384.30 | 5 | 14 |
3 | 13 | 1398.32 | 20 | 14.76 | 2560 | 756 | 2.92 / 385.06 | 4 | 18 |
4 | 13 | 708.84 | 20 | 14.90 | 1513 | 451 | 3.37 / 385.51 | 5 | 24 |
5 | 13 | 156.20 | 20 | 15.07 | 611 | 184 | 3.55 / 385.70 | 5 | 19 |
6 | 13 | 16.72 | 20 | 15.11 | 372 | 112 | 3.67 / 385.81 | 5 | 18 |
7 | 8 | 0.00 | 225 | 15.06 | 339 | 1149 | 4.81 / 386.96 | 5 | 139 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 17 | 15.08 | 493 | 126 | 0.13 / 377.45 | 5 | 5 |
2 | 7 | 2014.36 | 41 | 14.67 | 3463 | 2083 | 2.21 / 379.53 | 5 | 15 |
3 | 13 | 1356.04 | 20 | 14.76 | 2479 | 732 | 2.94 / 380.26 | 4 | 19 |
4 | 13 | 750.08 | 20 | 14.90 | 1545 | 460 | 3.40 / 380.72 | 5 | 25 |
5 | 13 | 152.56 | 20 | 15.08 | 567 | 171 | 3.57 / 380.89 | 5 | 21 |
6 | 13 | 14.96 | 20 | 15.12 | 355 | 107 | 3.68 / 381.00 | 5 | 16 |
7 | 8 | 0.04 | 225 | 15.06 | 337 | 1142 | 4.82 / 382.14 | 5 | 136 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 17 | 15.07 | 507 | 130 | 0.13 / 372.64 | 5 | 5 |
2 | 7 | 2003.56 | 40 | 14.69 | 3452 | 2028 | 2.16 / 374.67 | 5 | 14 |
3 | 13 | 1365.64 | 20 | 14.78 | 2489 | 736 | 2.89 / 375.40 | 4 | 20 |
4 | 13 | 793.72 | 20 | 14.89 | 1623 | 483 | 3.38 / 375.88 | 4 | 24 |
5 | 13 | 159.24 | 20 | 15.08 | 607 | 183 | 3.56 / 376.07 | 5 | 20 |
6 | 13 | 18.20 | 20 | 15.12 | 374 | 113 | 3.67 / 376.18 | 5 | 15 |
7 | 8 | 0.04 | 225 | 15.07 | 336 | 1139 | 4.81 / 377.32 | 5 | 136 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 17 | 15.08 | 479 | 123 | 0.12 / 367.78 | 5 | 5 |
2 | 7 | 2005.24 | 40 | 14.69 | 3465 | 2036 | 2.16 / 369.81 | 5 | 13 |
3 | 13 | 1411.00 | 20 | 14.76 | 2571 | 759 | 2.92 / 370.57 | 5 | 17 |
4 | 13 | 801.20 | 20 | 14.89 | 1656 | 493 | 3.41 / 371.06 | 5 | 24 |
5 | 13 | 162.12 | 20 | 15.08 | 609 | 184 | 3.59 / 371.25 | 5 | 20 |
6 | 13 | 18.88 | 20 | 15.12 | 367 | 111 | 3.71 / 371.36 | 5 | 16 |
7 | 8 | 0.00 | 227 | 15.07 | 336 | 1149 | 4.86 / 372.51 | 5 | 155 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 17 | 15.09 | 477 | 122 | 0.12 / 362.93 | 5 | 5 |
2 | 7 | 2004.72 | 41 | 14.68 | 3459 | 2082 | 2.20 / 365.02 | 5 | 13 |
3 | 13 | 1371.12 | 20 | 14.78 | 2503 | 740 | 2.94 / 365.76 | 4 | 21 |
4 | 13 | 730.12 | 20 | 14.91 | 1546 | 461 | 3.41 / 366.22 | 5 | 23 |
5 | 13 | 172.04 | 20 | 15.08 | 638 | 192 | 3.60 / 366.41 | 5 | 21 |
6 | 13 | 19.80 | 20 | 15.12 | 375 | 113 | 3.71 / 366.52 | 5 | 16 |
7 | 8 | 0.16 | 225 | 15.07 | 333 | 1129 | 4.84 / 367.65 | 5 | 144 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 17 | 15.09 | 485 | 124 | 0.12 / 358.09 | 5 | 5 |
2 | 7 | 2011.84 | 40 | 14.69 | 3455 | 2030 | 2.15 / 360.12 | 5 | 13 |
3 | 13 | 1451.96 | 20 | 14.76 | 2631 | 777 | 2.93 / 360.89 | 5 | 18 |
4 | 13 | 802.44 | 20 | 14.89 | 1649 | 491 | 3.42 / 361.38 | 5 | 23 |
5 | 13 | 166.88 | 20 | 15.09 | 617 | 186 | 3.61 / 361.57 | 5 | 19 |
6 | 13 | 19.00 | 20 | 15.12 | 369 | 112 | 3.72 / 361.68 | 5 | 15 |
7 | 8 | 0.12 | 227 | 15.08 | 330 | 1130 | 4.85 / 362.81 | 5 | 145 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 17 | 15.09 | 486 | 125 | 0.12 / 353.24 | 5 | 5 |
2 | 7 | 2012.88 | 40 | 14.69 | 3475 | 2042 | 2.17 / 355.28 | 5 | 11 |
3 | 13 | 1379.36 | 20 | 14.78 | 2528 | 747 | 2.91 / 356.03 | 5 | 19 |
4 | 13 | 780.60 | 20 | 14.90 | 1611 | 480 | 3.39 / 356.51 | 5 | 26 |
5 | 13 | 183.88 | 20 | 15.08 | 649 | 196 | 3.59 / 356.71 | 5 | 20 |
6 | 13 | 13.12 | 20 | 15.13 | 362 | 110 | 3.70 / 356.82 | 5 | 15 |
7 | 8 | 0.04 | 227 | 15.08 | 335 | 1147 | 4.85 / 357.96 | 5 | 156 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 17 | 15.10 | 487 | 125 | 0.13 / 348.40 | 5 | 5 |
2 | 7 | 2003.52 | 40 | 14.69 | 3465 | 2036 | 2.16 / 350.44 | 5 | 16 |
3 | 13 | 1404.68 | 20 | 14.78 | 2578 | 762 | 2.92 / 351.20 | 4 | 21 |
4 | 13 | 764.44 | 20 | 14.92 | 1597 | 477 | 3.40 / 351.68 | 5 | 24 |
5 | 13 | 179.68 | 20 | 15.09 | 649 | 196 | 3.60 / 351.87 | 5 | 17 |
6 | 8 | 0.00 | 248 | 15.09 | 332 | 1242 | 4.84 / 353.12 | 5 | 163 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 17 | 15.10 | 485 | 124 | 0.12 / 343.53 | 5 | 5 |
2 | 7 | 2011.40 | 41 | 14.69 | 3471 | 2091 | 2.22 / 345.62 | 5 | 13 |
3 | 13 | 1398.32 | 20 | 14.78 | 2549 | 753 | 2.97 / 346.37 | 4 | 19 |
4 | 13 | 779.76 | 20 | 14.91 | 1617 | 482 | 3.45 / 346.85 | 5 | 24 |
5 | 13 | 184.12 | 20 | 15.09 | 646 | 195 | 3.65 / 347.05 | 5 | 17 |
6 | 8 | 0.04 | 246 | 15.09 | 332 | 1232 | 4.88 / 348.28 | 5 | 154 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 17 | 15.09 | 502 | 129 | 0.13 / 338.77 | 5 | 5 |
2 | 7 | 2004.92 | 40 | 14.70 | 3464 | 2037 | 2.17 / 340.80 | 5 | 11 |
3 | 13 | 1406.52 | 20 | 14.78 | 2557 | 756 | 2.92 / 341.56 | 4 | 22 |
4 | 13 | 729.96 | 20 | 14.94 | 1513 | 452 | 3.37 / 342.01 | 5 | 24 |
5 | 13 | 185.92 | 20 | 15.11 | 616 | 186 | 3.56 / 342.20 | 5 | 18 |
6 | 8 | 0.16 | 246 | 15.10 | 324 | 1204 | 4.76 / 343.40 | 5 | 142 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 17 | 15.10 | 506 | 130 | 0.13 / 333.93 | 5 | 5 |
2 | 7 | 2003.52 | 40 | 14.69 | 3477 | 2043 | 2.17 / 335.97 | 5 | 15 |
3 | 13 | 1396.44 | 20 | 14.78 | 2562 | 757 | 2.93 / 336.73 | 4 | 18 |
4 | 13 | 751.76 | 20 | 14.93 | 1574 | 470 | 3.40 / 337.20 | 5 | 25 |
5 | 13 | 159.40 | 20 | 15.11 | 597 | 180 | 3.58 / 337.38 | 5 | 18 |
6 | 13 | 13.32 | 20 | 15.14 | 367 | 111 | 3.69 / 337.49 | 5 | 15 |
7 | 8 | 0.04 | 225 | 15.09 | 337 | 1144 | 4.84 / 338.64 | 5 | 151 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 17 | 15.11 | 492 | 126 | 0.13 / 329.20 | 5 | 5 |
2 | 7 | 2005.08 | 40 | 14.70 | 3453 | 2030 | 2.16 / 331.23 | 5 | 14 |
3 | 13 | 1291.76 | 20 | 14.82 | 2376 | 704 | 2.86 / 331.93 | 4 | 19 |
4 | 13 | 706.48 | 20 | 14.95 | 1473 | 440 | 3.30 / 332.37 | 5 | 26 |
5 | 13 | 156.84 | 20 | 15.12 | 571 | 173 | 3.47 / 332.54 | 5 | 20 |
6 | 8 | 0.08 | 244 | 15.10 | 341 | 1256 | 4.73 / 333.80 | 5 | 142 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 17 | 15.10 | 526 | 135 | 0.14 / 324.32 | 5 | 5 |
2 | 7 | 2004.16 | 40 | 14.71 | 3455 | 2033 | 2.17 / 326.35 | 5 | 11 |
3 | 13 | 1475.44 | 20 | 14.79 | 2656 | 786 | 2.95 / 327.14 | 4 | 17 |
4 | 13 | 774.04 | 20 | 14.93 | 1615 | 482 | 3.44 / 327.62 | 5 | 26 |
5 | 13 | 151.08 | 20 | 15.11 | 600 | 181 | 3.62 / 327.80 | 5 | 18 |
6 | 8 | 0.08 | 246 | 15.10 | 342 | 1270 | 4.89 / 329.07 | 5 | 153 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 17 | 15.10 | 511 | 131 | 0.13 / 319.49 | 5 | 5 |
2 | 7 | 2004.68 | 40 | 14.70 | 3473 | 2042 | 2.17 / 321.53 | 5 | 16 |
3 | 13 | 1376.72 | 20 | 14.81 | 2522 | 747 | 2.92 / 322.27 | 4 | 21 |
4 | 13 | 772.52 | 20 | 14.92 | 1612 | 481 | 3.40 / 322.76 | 5 | 26 |
5 | 13 | 103.56 | 20 | 15.13 | 518 | 157 | 3.56 / 322.91 | 5 | 20 |
6 | 8 | 0.00 | 244 | 15.10 | 345 | 1271 | 4.83 / 324.18 | 5 | 137 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 17 | 15.11 | 507 | 130 | 0.13 / 314.70 | 5 | 5 |
2 | 7 | 2007.16 | 41 | 14.71 | 3454 | 2083 | 2.21 / 316.78 | 5 | 15 |
3 | 13 | 1360.44 | 20 | 14.82 | 2469 | 732 | 2.95 / 317.51 | 5 | 19 |
4 | 13 | 683.04 | 20 | 14.96 | 1440 | 431 | 3.38 / 317.94 | 5 | 25 |
5 | 13 | 132.88 | 20 | 15.13 | 547 | 166 | 3.54 / 318.11 | 5 | 22 |
6 | 8 | -0.04 | 242 | 15.11 | 341 | 1247 | 4.79 / 319.35 | 5 | 130 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 17 | 15.11 | 508 | 130 | 0.13 / 309.86 | 5 | 5 |
2 | 7 | 2012.20 | 40 | 14.71 | 3481 | 2048 | 2.18 / 311.91 | 5 | 15 |
3 | 13 | 1381.76 | 20 | 14.80 | 2534 | 750 | 2.93 / 312.66 | 4 | 20 |
4 | 13 | 776.12 | 20 | 14.93 | 1609 | 480 | 3.41 / 313.14 | 4 | 25 |
5 | 13 | 152.12 | 20 | 15.13 | 603 | 182 | 3.59 / 313.32 | 5 | 19 |
6 | 8 | 0.00 | 244 | 15.12 | 338 | 1247 | 4.84 / 314.57 | 5 | 130 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 17 | 15.11 | 514 | 132 | 0.13 / 305.02 | 5 | 5 |
2 | 7 | 2004.48 | 40 | 14.71 | 3457 | 2034 | 2.17 / 307.05 | 5 | 14 |
3 | 13 | 1402.52 | 20 | 14.81 | 2568 | 761 | 2.93 / 307.81 | 4 | 19 |
4 | 13 | 750.20 | 20 | 14.95 | 1568 | 469 | 3.40 / 308.28 | 5 | 25 |
5 | 13 | 160.88 | 20 | 15.13 | 601 | 182 | 3.58 / 308.46 | 5 | 19 |
6 | 8 | 0.12 | 244 | 15.12 | 343 | 1265 | 4.84 / 309.73 | 5 | 130 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 17 | 15.10 | 509 | 131 | 0.13 / 300.11 | 5 | 5 |
2 | 7 | 2003.44 | 40 | 14.72 | 3472 | 2044 | 2.17 / 302.16 | 5 | 14 |
3 | 13 | 1375.96 | 20 | 14.82 | 2531 | 750 | 2.93 / 302.91 | 4 | 20 |
4 | 13 | 767.64 | 20 | 14.94 | 1600 | 478 | 3.40 / 303.39 | 5 | 26 |
5 | 13 | 171.16 | 20 | 15.12 | 642 | 194 | 3.60 / 303.58 | 5 | 20 |
6 | 8 | 0.04 | 246 | 15.11 | 351 | 1305 | 4.90 / 304.88 | 5 | 156 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 17 | 15.11 | 513 | 132 | 0.13 / 295.30 | 5 | 5 |
2 | 7 | 2007.20 | 40 | 14.72 | 3457 | 2035 | 2.17 / 297.34 | 5 | 14 |
3 | 13 | 1348.00 | 20 | 14.83 | 2470 | 733 | 2.90 / 298.07 | 5 | 21 |
4 | 13 | 737.52 | 20 | 14.96 | 1528 | 457 | 3.36 / 298.53 | 5 | 26 |
5 | 13 | 94.80 | 20 | 15.15 | 500 | 151 | 3.51 / 298.68 | 5 | 21 |
6 | 8 | 0.08 | 242 | 15.11 | 357 | 1305 | 4.81 / 299.98 | 5 | 140 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 17 | 15.11 | 520 | 134 | 0.13 / 290.52 | 5 | 5 |
2 | 7 | 2003.76 | 40 | 14.73 | 3447 | 2031 | 2.16 / 292.55 | 5 | 16 |
3 | 13 | 1312.00 | 20 | 14.84 | 2397 | 711 | 2.88 / 293.26 | 5 | 20 |
4 | 13 | 723.16 | 20 | 14.96 | 1510 | 452 | 3.33 / 293.71 | 5 | 27 |
5 | 13 | 90.40 | 20 | 15.15 | 477 | 145 | 3.47 / 293.86 | 5 | 23 |
6 | 8 | 0.04 | 242 | 15.11 | 359 | 1313 | 4.79 / 295.17 | 5 | 135 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 17 | 15.11 | 506 | 130 | 0.13 / 285.70 | 5 | 5 |
2 | 7 | 2009.24 | 41 | 14.72 | 3452 | 2083 | 2.21 / 287.78 | 5 | 14 |
3 | 13 | 1297.20 | 20 | 14.85 | 2371 | 704 | 2.92 / 288.49 | 4 | 19 |
4 | 13 | 727.76 | 20 | 14.96 | 1526 | 457 | 3.37 / 288.95 | 5 | 26 |
5 | 13 | 78.12 | 20 | 15.16 | 457 | 139 | 3.51 / 289.08 | 5 | 22 |
6 | 8 | -0.12 | 242 | 15.12 | 355 | 1299 | 4.81 / 290.38 | 5 | 142 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 17 | 15.13 | 510 | 131 | 0.13 / 280.87 | 5 | 5 |
2 | 7 | 2011.40 | 40 | 14.71 | 3492 | 2055 | 2.19 / 282.93 | 5 | 15 |
3 | 13 | 1358.44 | 20 | 14.83 | 2501 | 742 | 2.93 / 283.67 | 5 | 20 |
4 | 13 | 707.12 | 20 | 14.96 | 1525 | 456 | 3.38 / 284.13 | 5 | 27 |
5 | 13 | 73.76 | 20 | 15.16 | 482 | 146 | 3.53 / 284.27 | 5 | 22 |
6 | 8 | 0.04 | 242 | 15.12 | 355 | 1299 | 4.83 / 285.57 | 5 | 143 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 17 | 15.13 | 505 | 130 | 0.13 / 276.03 | 5 | 5 |
2 | 7 | 2014.68 | 40 | 14.73 | 3469 | 2044 | 2.17 / 278.07 | 5 | 15 |
3 | 13 | 1386.12 | 20 | 14.82 | 2524 | 748 | 2.92 / 278.82 | 4 | 19 |
4 | 13 | 769.76 | 20 | 14.96 | 1579 | 472 | 3.39 / 279.29 | 5 | 25 |
5 | 13 | 100.12 | 20 | 15.16 | 482 | 146 | 3.54 / 279.44 | 5 | 19 |
6 | 13 | 30.20 | 20 | 15.17 | 364 | 110 | 3.65 / 279.55 | 5 | 18 |
7 | 8 | 0.00 | 225 | 15.13 | 350 | 1191 | 4.84 / 280.74 | 5 | 140 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 17 | 15.13 | 519 | 133 | 0.13 / 271.24 | 5 | 5 |
2 | 7 | 2013.00 | 40 | 14.71 | 3486 | 2051 | 2.18 / 273.29 | 5 | 15 |
3 | 13 | 1334.68 | 20 | 14.84 | 2459 | 730 | 2.91 / 274.02 | 4 | 20 |
4 | 13 | 693.96 | 20 | 14.97 | 1505 | 451 | 3.37 / 274.47 | 5 | 25 |
5 | 13 | 143.20 | 20 | 15.15 | 587 | 178 | 3.54 / 274.64 | 5 | 19 |
6 | 8 | 0.08 | 244 | 15.13 | 340 | 1255 | 4.80 / 275.90 | 5 | 152 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 16 | 15.13 | 517 | 125 | 0.13 / 266.37 | 5 | 5 |
2 | 7 | 2005.52 | 41 | 14.73 | 3453 | 2085 | 2.21 / 268.45 | 5 | 13 |
3 | 13 | 1362.80 | 20 | 14.83 | 2484 | 737 | 2.95 / 269.19 | 4 | 20 |
4 | 13 | 715.16 | 20 | 14.98 | 1524 | 457 | 3.40 / 269.65 | 5 | 25 |
5 | 13 | 123.08 | 20 | 15.16 | 563 | 171 | 3.57 / 269.82 | 5 | 18 |
6 | 8 | 0.16 | 244 | 15.14 | 348 | 1286 | 4.86 / 271.10 | 5 | 135 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 16 | 15.13 | 504 | 122 | 0.12 / 261.51 | 5 | 5 |
2 | 7 | 2004.72 | 40 | 14.74 | 3446 | 2032 | 2.15 / 263.54 | 5 | 14 |
3 | 13 | 1409.24 | 20 | 14.83 | 2570 | 762 | 2.92 / 264.30 | 4 | 19 |
4 | 13 | 791.08 | 20 | 14.96 | 1622 | 485 | 3.40 / 264.79 | 5 | 25 |
5 | 13 | 116.64 | 20 | 15.16 | 548 | 166 | 3.57 / 264.96 | 5 | 19 |
6 | 8 | -0.04 | 244 | 15.14 | 348 | 1286 | 4.85 / 266.24 | 5 | 137 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 16 | 15.13 | 501 | 121 | 0.12 / 256.73 | 5 | 5 |
2 | 7 | 2007.44 | 40 | 14.73 | 3453 | 2035 | 2.16 / 258.77 | 5 | 14 |
3 | 13 | 1325.56 | 20 | 14.85 | 2444 | 726 | 2.88 / 259.49 | 5 | 20 |
4 | 13 | 719.56 | 20 | 14.97 | 1543 | 462 | 3.34 / 259.96 | 4 | 27 |
5 | 13 | 66.20 | 20 | 15.17 | 472 | 143 | 3.49 / 260.10 | 5 | 21 |
6 | 8 | -0.04 | 242 | 15.13 | 352 | 1289 | 4.78 / 261.39 | 5 | 142 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 16 | 15.14 | 492 | 119 | 0.12 / 251.97 | 5 | 5 |
2 | 7 | 2013.88 | 40 | 14.73 | 3467 | 2043 | 2.16 / 254.02 | 5 | 14 |
3 | 13 | 1437.20 | 20 | 14.83 | 2593 | 769 | 2.93 / 254.79 | 4 | 20 |
4 | 13 | 726.96 | 20 | 14.98 | 1518 | 455 | 3.39 / 255.24 | 4 | 26 |
5 | 13 | 65.00 | 20 | 15.17 | 436 | 132 | 3.52 / 255.37 | 5 | 24 |
6 | 8 | -0.04 | 240 | 15.14 | 341 | 1239 | 4.76 / 256.61 | 5 | 136 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 16 | 15.14 | 529 | 128 | 0.13 / 247.24 | 5 | 5 |
2 | 7 | 2004.60 | 40 | 14.74 | 3466 | 2044 | 2.17 / 249.28 | 5 | 14 |
3 | 13 | 1309.60 | 20 | 14.86 | 2415 | 718 | 2.89 / 250.00 | 5 | 20 |
4 | 13 | 707.20 | 20 | 14.99 | 1499 | 449 | 3.34 / 250.45 | 5 | 26 |
5 | 13 | 106.56 | 20 | 15.17 | 524 | 159 | 3.50 / 250.61 | 5 | 20 |
6 | 8 | 0.24 | 244 | 15.15 | 338 | 1249 | 4.75 / 251.86 | 5 | 152 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 16 | 15.15 | 480 | 116 | 0.12 / 242.45 | 5 | 5 |
2 | 7 | 2012.48 | 40 | 14.73 | 3466 | 2042 | 2.16 / 244.49 | 5 | 12 |
3 | 13 | 1337.32 | 20 | 14.86 | 2448 | 728 | 2.89 / 245.22 | 4 | 20 |
4 | 13 | 728.80 | 20 | 14.98 | 1525 | 457 | 3.34 / 245.68 | 4 | 25 |
5 | 13 | 136.84 | 20 | 15.17 | 539 | 164 | 3.51 / 245.84 | 5 | 17 |
6 | 8 | 0.12 | 244 | 15.15 | 343 | 1268 | 4.77 / 247.11 | 5 | 147 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 16 | 15.16 | 477 | 116 | 0.12 / 237.63 | 5 | 5 |
2 | 7 | 2007.44 | 41 | 14.73 | 3471 | 2096 | 2.21 / 239.73 | 5 | 16 |
3 | 13 | 1347.40 | 20 | 14.86 | 2476 | 736 | 2.95 / 240.47 | 4 | 20 |
4 | 13 | 738.28 | 20 | 14.99 | 1529 | 458 | 3.41 / 240.92 | 5 | 25 |
5 | 13 | 177.36 | 20 | 15.16 | 629 | 191 | 3.60 / 241.11 | 5 | 17 |
6 | 8 | -0.04 | 246 | 15.16 | 327 | 1220 | 4.82 / 242.33 | 5 | 160 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 16 | 15.17 | 469 | 114 | 0.11 / 232.88 | 5 | 5 |
2 | 7 | 2012.44 | 40 | 14.74 | 3459 | 2039 | 2.15 / 234.92 | 5 | 14 |
3 | 13 | 1360.00 | 20 | 14.86 | 2476 | 736 | 2.89 / 235.65 | 4 | 21 |
4 | 13 | 720.60 | 20 | 15.00 | 1528 | 458 | 3.35 / 236.11 | 5 | 25 |
5 | 13 | 168.28 | 20 | 15.17 | 610 | 185 | 3.53 / 236.30 | 5 | 17 |
6 | 8 | 0.12 | 244 | 15.16 | 330 | 1221 | 4.75 / 237.52 | 5 | 143 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 16 | 15.15 | 503 | 122 | 0.12 / 228.16 | 5 | 5 |
2 | 7 | 2007.08 | 40 | 14.74 | 3455 | 2037 | 2.16 / 230.20 | 5 | 14 |
3 | 13 | 1360.32 | 20 | 14.86 | 2472 | 735 | 2.89 / 230.93 | 4 | 20 |
4 | 13 | 751.24 | 20 | 15.00 | 1536 | 461 | 3.35 / 231.39 | 5 | 26 |
5 | 13 | 155.40 | 20 | 15.18 | 566 | 172 | 3.53 / 231.57 | 5 | 18 |
6 | 8 | 0.12 | 244 | 15.17 | 324 | 1199 | 4.73 / 232.76 | 5 | 149 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 16 | 15.13 | 513 | 124 | 0.12 / 223.32 | 5 | 5 |
2 | 7 | 2008.80 | 40 | 14.74 | 3480 | 2052 | 2.18 / 225.38 | 5 | 14 |
3 | 13 | 1415.20 | 20 | 14.85 | 2580 | 766 | 2.94 / 226.14 | 4 | 19 |
4 | 13 | 715.88 | 20 | 14.99 | 1534 | 460 | 3.40 / 226.60 | 4 | 27 |
5 | 13 | 137.40 | 20 | 15.17 | 588 | 178 | 3.58 / 226.78 | 5 | 24 |
6 | 8 | 0.04 | 242 | 15.15 | 343 | 1258 | 4.84 / 228.04 | 5 | 143 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 16 | 15.14 | 524 | 127 | 0.13 / 218.46 | 5 | 5 |
2 | 7 | 2007.84 | 40 | 14.75 | 3458 | 2040 | 2.17 / 220.50 | 5 | 15 |
3 | 13 | 1440.76 | 20 | 14.85 | 2619 | 778 | 2.94 / 221.28 | 4 | 21 |
4 | 13 | 698.32 | 20 | 15.01 | 1483 | 445 | 3.39 / 221.72 | 4 | 26 |
5 | 13 | 106.52 | 20 | 15.18 | 539 | 164 | 3.55 / 221.88 | 5 | 25 |
6 | 8 | 0.00 | 242 | 15.15 | 359 | 1316 | 4.87 / 223.20 | 5 | 139 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 16 | 15.15 | 508 | 123 | 0.12 / 213.61 | 5 | 5 |
2 | 7 | 2005.28 | 40 | 14.75 | 3473 | 2049 | 2.17 / 215.66 | 5 | 14 |
3 | 13 | 1351.52 | 20 | 14.86 | 2500 | 743 | 2.92 / 216.40 | 5 | 19 |
4 | 13 | 728.40 | 20 | 14.99 | 1554 | 466 | 3.38 / 216.87 | 5 | 27 |
5 | 13 | 79.24 | 20 | 15.19 | 486 | 148 | 3.53 / 217.02 | 5 | 23 |
6 | 8 | 0.16 | 240 | 15.15 | 361 | 1313 | 4.84 / 218.33 | 5 | 135 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 16 | 15.15 | 501 | 121 | 0.12 / 208.81 | 5 | 5 |
2 | 7 | 2003.92 | 40 | 14.76 | 3445 | 2034 | 2.16 / 210.84 | 5 | 15 |
3 | 13 | 1386.36 | 20 | 14.86 | 2528 | 751 | 2.91 / 211.59 | 4 | 19 |
4 | 13 | 741.96 | 20 | 14.99 | 1570 | 471 | 3.38 / 212.06 | 4 | 27 |
5 | 13 | 66.00 | 20 | 15.20 | 467 | 142 | 3.52 / 212.21 | 5 | 22 |
6 | 8 | -0.04 | 242 | 15.16 | 350 | 1284 | 4.80 / 213.49 | 5 | 137 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 16 | 15.15 | 488 | 118 | 0.12 / 203.97 | 5 | 5 |
2 | 7 | 2005.76 | 41 | 14.75 | 3476 | 2102 | 2.22 / 206.07 | 5 | 13 |
3 | 13 | 1344.68 | 20 | 14.88 | 2456 | 731 | 2.95 / 206.81 | 4 | 21 |
4 | 13 | 697.92 | 20 | 15.01 | 1474 | 442 | 3.39 / 207.25 | 5 | 26 |
5 | 13 | 95.88 | 20 | 15.19 | 484 | 147 | 3.54 / 207.39 | 5 | 23 |
6 | 8 | 0.12 | 242 | 15.16 | 352 | 1291 | 4.83 / 208.69 | 5 | 146 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 16 | 15.15 | 515 | 125 | 0.12 / 199.25 | 5 | 5 |
2 | 7 | 2014.16 | 40 | 14.75 | 3468 | 2046 | 2.17 / 201.29 | 5 | 14 |
3 | 13 | 1343.16 | 20 | 14.88 | 2450 | 729 | 2.90 / 202.02 | 4 | 23 |
4 | 13 | 658.92 | 20 | 15.03 | 1411 | 424 | 3.32 / 202.45 | 5 | 27 |
5 | 13 | 76.92 | 20 | 15.20 | 452 | 137 | 3.46 / 202.58 | 5 | 24 |
6 | 8 | 0.04 | 242 | 15.16 | 346 | 1269 | 4.73 / 203.85 | 5 | 152 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 16 | 15.15 | 504 | 122 | 0.12 / 194.34 | 5 | 5 |
2 | 7 | 2010.84 | 41 | 14.75 | 3467 | 2097 | 2.22 / 196.43 | 5 | 14 |
3 | 13 | 1365.48 | 20 | 14.87 | 2513 | 747 | 2.97 / 197.18 | 5 | 20 |
4 | 13 | 708.44 | 20 | 15.01 | 1506 | 452 | 3.42 / 197.63 | 5 | 27 |
5 | 13 | 75.12 | 20 | 15.19 | 495 | 150 | 3.57 / 197.78 | 5 | 25 |
6 | 8 | -0.04 | 242 | 15.16 | 365 | 1339 | 4.91 / 199.12 | 5 | 154 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 16 | 15.16 | 512 | 124 | 0.12 / 189.60 | 5 | 5 |
2 | 7 | 2012.72 | 40 | 14.76 | 3461 | 2043 | 2.17 / 191.64 | 5 | 16 |
3 | 13 | 1331.92 | 20 | 14.89 | 2427 | 723 | 2.89 / 192.37 | 4 | 21 |
4 | 13 | 648.40 | 20 | 15.04 | 1389 | 418 | 3.31 / 192.78 | 5 | 28 |
5 | 13 | 93.24 | 20 | 15.20 | 480 | 146 | 3.45 / 192.93 | 5 | 25 |
6 | 8 | -0.04 | 242 | 15.16 | 350 | 1284 | 4.74 / 194.21 | 5 | 151 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 16 | 15.17 | 506 | 123 | 0.12 / 184.71 | 5 | 5 |
2 | 7 | 2013.44 | 41 | 14.75 | 3486 | 2108 | 2.23 / 186.82 | 5 | 14 |
3 | 13 | 1289.24 | 20 | 14.90 | 2400 | 715 | 2.95 / 187.54 | 5 | 20 |
4 | 13 | 758.56 | 20 | 15.00 | 1590 | 477 | 3.42 / 188.01 | 5 | 27 |
5 | 13 | 66.92 | 20 | 15.21 | 462 | 141 | 3.56 / 188.16 | 5 | 23 |
6 | 8 | -0.16 | 242 | 15.17 | 360 | 1322 | 4.89 / 189.48 | 5 | 149 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 16 | 15.16 | 519 | 126 | 0.13 / 179.91 | 5 | 5 |
2 | 7 | 2004.84 | 41 | 14.76 | 3470 | 2100 | 2.23 / 182.01 | 5 | 16 |
3 | 13 | 1273.12 | 20 | 14.90 | 2368 | 706 | 2.93 / 182.71 | 4 | 23 |
4 | 13 | 600.96 | 20 | 15.04 | 1367 | 411 | 3.34 / 183.13 | 4 | 28 |
5 | 13 | 93.80 | 20 | 15.20 | 514 | 156 | 3.50 / 183.28 | 5 | 25 |
6 | 8 | 0.16 | 242 | 15.16 | 357 | 1310 | 4.81 / 184.59 | 5 | 143 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 16 | 15.17 | 511 | 124 | 0.12 / 175.08 | 5 | 5 |
2 | 7 | 2005.00 | 40 | 14.76 | 3446 | 2035 | 2.16 / 177.12 | 5 | 13 |
3 | 13 | 1368.16 | 20 | 14.89 | 2479 | 738 | 2.90 / 177.86 | 4 | 20 |
4 | 13 | 765.48 | 20 | 15.01 | 1564 | 470 | 3.37 / 178.33 | 4 | 27 |
5 | 13 | 75.56 | 20 | 15.21 | 458 | 139 | 3.51 / 178.46 | 5 | 25 |
6 | 8 | 0.08 | 242 | 15.17 | 359 | 1318 | 4.82 / 179.78 | 5 | 144 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 16 | 15.19 | 493 | 120 | 0.12 / 170.30 | 5 | 5 |
2 | 7 | 2008.96 | 40 | 14.77 | 3444 | 2035 | 2.15 / 172.33 | 5 | 15 |
3 | 13 | 1330.72 | 20 | 14.90 | 2425 | 723 | 2.88 / 173.05 | 4 | 21 |
4 | 13 | 721.60 | 20 | 15.02 | 1525 | 458 | 3.34 / 173.51 | 4 | 26 |
5 | 13 | 93.80 | 20 | 15.21 | 510 | 155 | 3.49 / 173.67 | 5 | 21 |
6 | 8 | 0.00 | 244 | 15.18 | 349 | 1293 | 4.78 / 174.96 | 5 | 147 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 16 | 15.20 | 450 | 109 | 0.11 / 165.55 | 5 | 5 |
2 | 7 | 2011.04 | 40 | 14.77 | 3458 | 2043 | 2.15 / 167.59 | 5 | 17 |
3 | 13 | 1368.40 | 20 | 14.89 | 2485 | 740 | 2.89 / 168.33 | 4 | 21 |
4 | 13 | 734.96 | 20 | 15.02 | 1548 | 465 | 3.36 / 168.80 | 5 | 27 |
5 | 13 | 108.04 | 20 | 15.21 | 517 | 157 | 3.51 / 168.95 | 5 | 20 |
6 | 8 | 0.16 | 244 | 15.19 | 330 | 1223 | 4.74 / 170.18 | 5 | 150 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 16 | 15.20 | 483 | 117 | 0.12 / 160.79 | 5 | 5 |
2 | 7 | 2008.20 | 40 | 14.77 | 3451 | 2039 | 2.16 / 162.83 | 5 | 14 |
3 | 13 | 1410.60 | 20 | 14.88 | 2555 | 760 | 2.92 / 163.59 | 4 | 21 |
4 | 13 | 768.20 | 20 | 15.03 | 1567 | 471 | 3.39 / 164.06 | 5 | 25 |
5 | 13 | 176.76 | 20 | 15.20 | 606 | 184 | 3.57 / 164.24 | 5 | 18 |
6 | 8 | 0.16 | 246 | 15.20 | 320 | 1197 | 4.77 / 165.44 | 5 | 142 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 16 | 15.21 | 489 | 119 | 0.12 / 156.03 | 5 | 5 |
2 | 7 | 2004.88 | 40 | 14.77 | 3439 | 2032 | 2.15 / 158.06 | 5 | 15 |
3 | 13 | 1318.00 | 20 | 14.91 | 2409 | 718 | 2.87 / 158.78 | 4 | 20 |
4 | 13 | 787.92 | 20 | 15.02 | 1595 | 479 | 3.35 / 159.26 | 5 | 25 |
5 | 13 | 183.68 | 20 | 15.20 | 608 | 185 | 3.53 / 159.45 | 5 | 17 |
6 | 8 | 0.08 | 246 | 15.20 | 327 | 1223 | 4.76 / 160.67 | 5 | 150 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 16 | 15.20 | 474 | 115 | 0.12 / 151.23 | 5 | 5 |
2 | 7 | 2011.08 | 40 | 14.78 | 3471 | 2052 | 2.17 / 153.28 | 5 | 14 |
3 | 13 | 1398.64 | 20 | 14.89 | 2554 | 761 | 2.93 / 154.04 | 4 | 21 |
4 | 13 | 790.96 | 20 | 15.02 | 1637 | 492 | 3.42 / 154.53 | 5 | 24 |
5 | 13 | 196.40 | 20 | 15.20 | 650 | 198 | 3.62 / 154.73 | 5 | 16 |
6 | 8 | 0.24 | 246 | 15.21 | 317 | 1186 | 4.80 / 155.91 | 5 | 140 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 16 | 15.19 | 494 | 120 | 0.12 / 146.41 | 5 | 5 |
2 | 7 | 2008.24 | 40 | 14.78 | 3473 | 2053 | 2.17 / 148.46 | 5 | 15 |
3 | 13 | 1374.88 | 20 | 14.90 | 2501 | 745 | 2.92 / 149.21 | 4 | 21 |
4 | 13 | 724.92 | 20 | 15.04 | 1535 | 462 | 3.38 / 149.67 | 5 | 25 |
5 | 13 | 207.04 | 20 | 15.20 | 688 | 209 | 3.59 / 149.88 | 5 | 17 |
6 | 8 | 0.08 | 246 | 15.21 | 329 | 1231 | 4.82 / 151.11 | 5 | 145 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 16 | 15.20 | 474 | 115 | 0.12 / 141.51 | 5 | 5 |
2 | 7 | 2011.32 | 40 | 14.78 | 3475 | 2054 | 2.17 / 143.56 | 5 | 15 |
3 | 13 | 1389.44 | 20 | 14.90 | 2540 | 757 | 2.93 / 144.32 | 4 | 21 |
4 | 13 | 776.08 | 20 | 15.03 | 1609 | 484 | 3.41 / 144.80 | 5 | 25 |
5 | 13 | 212.20 | 20 | 15.20 | 669 | 203 | 3.61 / 145.01 | 5 | 18 |
6 | 13 | 94.68 | 20 | 15.23 | 487 | 148 | 3.76 / 145.15 | 5 | 16 |
7 | 8 | 0.20 | 227 | 15.20 | 329 | 1135 | 4.90 / 146.29 | 5 | 151 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 16 | 15.21 | 446 | 109 | 0.11 / 136.64 | 5 | 5 |
2 | 7 | 2012.64 | 40 | 14.79 | 3457 | 2045 | 2.15 / 138.69 | 5 | 13 |
3 | 13 | 1326.20 | 20 | 14.91 | 2439 | 727 | 2.88 / 139.41 | 4 | 20 |
4 | 13 | 805.36 | 20 | 15.02 | 1651 | 496 | 3.38 / 139.91 | 5 | 24 |
5 | 13 | 236.04 | 20 | 15.19 | 716 | 218 | 3.59 / 140.13 | 5 | 18 |
6 | 13 | 77.64 | 20 | 15.23 | 457 | 139 | 3.73 / 140.27 | 5 | 14 |
7 | 8 | 0.12 | 227 | 15.21 | 326 | 1126 | 4.86 / 141.39 | 5 | 147 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 16 | 15.21 | 442 | 108 | 0.11 / 131.87 | 5 | 5 |
2 | 7 | 2010.40 | 40 | 14.79 | 3463 | 2049 | 2.16 / 133.92 | 5 | 15 |
3 | 13 | 1376.60 | 20 | 14.91 | 2500 | 745 | 2.90 / 134.66 | 4 | 20 |
4 | 13 | 736.40 | 20 | 15.05 | 1516 | 456 | 3.36 / 135.12 | 5 | 24 |
5 | 13 | 219.20 | 20 | 15.20 | 670 | 204 | 3.56 / 135.32 | 5 | 18 |
6 | 13 | 71.12 | 20 | 15.24 | 412 | 126 | 3.69 / 135.45 | 5 | 15 |
7 | 8 | 0.04 | 227 | 15.21 | 315 | 1088 | 4.77 / 136.53 | 5 | 141 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 16 | 15.21 | 490 | 119 | 0.12 / 127.07 | 5 | 5 |
2 | 7 | 2013.12 | 40 | 14.80 | 3446 | 2040 | 2.16 / 129.11 | 5 | 15 |
3 | 13 | 1369.76 | 20 | 14.92 | 2481 | 740 | 2.90 / 129.85 | 5 | 20 |
4 | 13 | 734.56 | 20 | 15.06 | 1511 | 455 | 3.35 / 130.31 | 5 | 24 |
5 | 13 | 218.44 | 20 | 15.21 | 662 | 201 | 3.56 / 130.51 | 5 | 18 |
6 | 13 | 66.16 | 20 | 15.25 | 402 | 123 | 3.68 / 130.63 | 5 | 14 |
7 | 8 | 0.16 | 227 | 15.21 | 326 | 1126 | 4.80 / 131.76 | 5 | 147 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 16 | 15.21 | 486 | 118 | 0.12 / 122.18 | 5 | 5 |
2 | 7 | 2008.64 | 40 | 14.81 | 3461 | 2050 | 2.17 / 124.23 | 5 | 14 |
3 | 13 | 1404.56 | 20 | 14.91 | 2569 | 766 | 2.93 / 125.00 | 4 | 19 |
4 | 13 | 786.60 | 20 | 15.04 | 1614 | 485 | 3.42 / 125.48 | 5 | 25 |
5 | 13 | 224.88 | 20 | 15.21 | 707 | 215 | 3.64 / 125.70 | 5 | 17 |
6 | 13 | 69.56 | 20 | 15.24 | 446 | 136 | 3.77 / 125.83 | 5 | 14 |
7 | 8 | 0.16 | 227 | 15.22 | 325 | 1123 | 4.89 / 126.95 | 5 | 146 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 16 | 15.21 | 479 | 117 | 0.12 / 117.38 | 5 | 5 |
2 | 7 | 2012.28 | 40 | 14.80 | 3467 | 2052 | 2.17 / 119.43 | 5 | 14 |
3 | 13 | 1371.08 | 20 | 14.92 | 2492 | 744 | 2.91 / 120.18 | 4 | 19 |
4 | 13 | 728.04 | 20 | 15.06 | 1496 | 451 | 3.36 / 120.63 | 5 | 25 |
5 | 13 | 173.16 | 20 | 15.23 | 588 | 179 | 3.54 / 120.81 | 5 | 17 |
6 | 13 | 64.68 | 20 | 15.25 | 399 | 122 | 3.66 / 120.93 | 5 | 15 |
7 | 8 | 0.04 | 227 | 15.22 | 328 | 1133 | 4.80 / 122.06 | 5 | 156 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 16 | 15.22 | 478 | 116 | 0.12 / 112.56 | 5 | 5 |
2 | 7 | 2009.64 | 41 | 14.80 | 3468 | 2104 | 2.22 / 114.66 | 5 | 14 |
3 | 13 | 1327.32 | 20 | 14.93 | 2425 | 724 | 2.94 / 115.39 | 4 | 19 |
4 | 13 | 754.96 | 20 | 15.06 | 1537 | 463 | 3.41 / 115.85 | 5 | 25 |
5 | 13 | 182.12 | 20 | 15.22 | 615 | 187 | 3.60 / 116.04 | 5 | 18 |
6 | 13 | 41.76 | 20 | 15.25 | 397 | 121 | 3.72 / 116.16 | 5 | 14 |
7 | 8 | 0.08 | 223 | 15.22 | 326 | 1106 | 4.82 / 117.26 | 5 | 129 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 16 | 15.22 | 484 | 118 | 0.12 / 107.75 | 5 | 5 |
2 | 7 | 2011.20 | 40 | 14.81 | 3459 | 2049 | 2.17 / 109.80 | 5 | 14 |
3 | 13 | 1373.84 | 20 | 14.93 | 2505 | 748 | 2.91 / 110.55 | 4 | 20 |
4 | 13 | 768.20 | 20 | 15.05 | 1577 | 475 | 3.39 / 111.02 | 5 | 24 |
5 | 13 | 215.16 | 20 | 15.22 | 659 | 201 | 3.59 / 111.22 | 5 | 19 |
6 | 13 | 64.16 | 20 | 15.26 | 399 | 122 | 3.71 / 111.34 | 5 | 15 |
7 | 8 | 0.12 | 225 | 15.23 | 320 | 1097 | 4.81 / 112.44 | 5 | 136 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 16 | 15.22 | 477 | 116 | 0.12 / 102.83 | 5 | 5 |
2 | 7 | 2003.96 | 40 | 14.82 | 3456 | 2049 | 2.16 / 104.88 | 9 | 14 |
3 | 13 | 1404.40 | 20 | 14.92 | 2568 | 766 | 2.93 / 105.64 | 4 | 20 |
4 | 13 | 825.52 | 20 | 15.03 | 1686 | 507 | 3.44 / 106.15 | 5 | 25 |
5 | 13 | 212.08 | 20 | 15.22 | 681 | 207 | 3.65 / 106.36 | 5 | 18 |
6 | 13 | 64.04 | 20 | 15.25 | 440 | 134 | 3.78 / 106.49 | 5 | 15 |
7 | 8 | 0.04 | 227 | 15.22 | 330 | 1140 | 4.92 / 107.63 | 5 | 143 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 16 | 15.23 | 474 | 116 | 0.12 / 97.92 | 5 | 5 |
2 | 7 | 2005.32 | 40 | 14.81 | 3481 | 2062 | 2.18 / 99.98 | 5 | 13 |
3 | 13 | 1375.72 | 20 | 14.93 | 2528 | 755 | 2.93 / 100.74 | 4 | 21 |
4 | 13 | 802.28 | 20 | 15.05 | 1648 | 496 | 3.43 / 101.24 | 5 | 24 |
5 | 13 | 198.68 | 20 | 15.23 | 663 | 202 | 3.63 / 101.44 | 5 | 17 |
6 | 13 | 86.32 | 20 | 15.25 | 475 | 145 | 3.78 / 101.58 | 5 | 15 |
7 | 8 | 0.16 | 227 | 15.23 | 327 | 1131 | 4.91 / 102.71 | 5 | 136 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 16 | 15.22 | 502 | 122 | 0.12 / 93.12 | 5 | 5 |
2 | 7 | 2014.52 | 40 | 14.82 | 3458 | 2050 | 2.17 / 95.17 | 5 | 15 |
3 | 13 | 1336.08 | 20 | 14.95 | 2433 | 727 | 2.90 / 95.90 | 4 | 23 |
4 | 13 | 746.68 | 20 | 15.07 | 1535 | 463 | 3.36 / 96.36 | 5 | 25 |
5 | 13 | 228.08 | 20 | 15.23 | 680 | 207 | 3.57 / 96.57 | 5 | 18 |
6 | 13 | 74.92 | 20 | 15.26 | 436 | 133 | 3.70 / 96.70 | 5 | 14 |
7 | 8 | 0.12 | 225 | 15.23 | 323 | 1107 | 4.81 / 97.81 | 5 | 134 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 16 | 15.21 | 509 | 124 | 0.12 / 88.23 | 5 | 5 |
2 | 7 | 2005.44 | 40 | 14.83 | 3454 | 2049 | 2.17 / 90.28 | 5 | 15 |
3 | 13 | 1342.00 | 20 | 14.94 | 2470 | 738 | 2.91 / 91.02 | 4 | 22 |
4 | 13 | 738.08 | 20 | 15.07 | 1547 | 466 | 3.38 / 91.48 | 5 | 26 |
5 | 13 | 175.72 | 20 | 15.23 | 647 | 197 | 3.57 / 91.68 | 5 | 21 |
6 | 13 | 60.40 | 20 | 15.25 | 452 | 138 | 3.71 / 91.82 | 5 | 17 |
7 | 8 | 0.08 | 225 | 15.22 | 344 | 1178 | 4.89 / 93.00 | 5 | 137 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 16 | 15.22 | 507 | 123 | 0.12 / 83.46 | 5 | 5 |
2 | 7 | 2003.40 | 40 | 14.83 | 3433 | 2036 | 2.16 / 85.49 | 5 | 15 |
3 | 13 | 1238.16 | 20 | 14.97 | 2285 | 684 | 2.84 / 86.18 | 4 | 22 |
4 | 13 | 714.36 | 20 | 15.07 | 1490 | 449 | 3.29 / 86.63 | 5 | 27 |
5 | 13 | 57.72 | 20 | 15.26 | 444 | 136 | 3.43 / 86.76 | 5 | 24 |
6 | 13 | 31.72 | 20 | 15.25 | 435 | 133 | 3.56 / 86.90 | 5 | 25 |
7 | 8 | 0.24 | 220 | 15.21 | 362 | 1211 | 4.77 / 88.11 | 5 | 136 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 16 | 15.22 | 483 | 118 | 0.12 / 78.07 | 5 | 5 |
2 | 7 | 2003.12 | 40 | 14.83 | 3460 | 2052 | 2.17 / 80.12 | 5 | 14 |
3 | 13 | 1592.92 | 20 | 14.89 | 2853 | 850 | 3.02 / 80.97 | 5 | 19 |
4 | 13 | 1570.36 | 20 | 14.84 | 2826 | 839 | 3.86 / 81.81 | 5 | 21 |
5 | 13 | 142.20 | 20 | 15.23 | 607 | 185 | 4.04 / 81.99 | 5 | 23 |
6 | 13 | 36.80 | 20 | 15.26 | 428 | 131 | 4.17 / 82.13 | 5 | 20 |
7 | 8 | 0.00 | 227 | 15.22 | 350 | 1209 | 5.38 / 83.33 | 5 | 139 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 16 | 15.24 | 485 | 118 | 0.12 / 73.27 | 5 | 5 |
2 | 7 | 2012.20 | 40 | 14.82 | 3467 | 2055 | 2.17 / 75.33 | 5 | 15 |
3 | 13 | 1305.36 | 20 | 14.96 | 2394 | 716 | 2.89 / 76.04 | 4 | 20 |
4 | 13 | 733.00 | 20 | 15.08 | 1511 | 456 | 3.35 / 76.50 | 5 | 26 |
5 | 13 | 132.12 | 20 | 15.25 | 546 | 167 | 3.51 / 76.66 | 5 | 18 |
6 | 13 | 59.88 | 20 | 15.26 | 443 | 135 | 3.65 / 76.80 | 5 | 17 |
7 | 8 | 0.08 | 225 | 15.23 | 336 | 1151 | 4.80 / 77.95 | 5 | 146 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 16 | 15.24 | 467 | 114 | 0.11 / 68.48 | 5 | 5 |
2 | 7 | 2005.68 | 40 | 14.84 | 3456 | 2051 | 2.17 / 70.53 | 5 | 14 |
3 | 13 | 1362.32 | 20 | 14.94 | 2504 | 748 | 2.91 / 71.27 | 4 | 22 |
4 | 13 | 708.92 | 20 | 15.08 | 1514 | 457 | 3.37 / 71.73 | 5 | 25 |
5 | 13 | 156.08 | 20 | 15.25 | 588 | 179 | 3.55 / 71.91 | 5 | 18 |
6 | 13 | 51.44 | 20 | 15.27 | 418 | 128 | 3.68 / 72.04 | 5 | 15 |
7 | 8 | 0.12 | 225 | 15.24 | 325 | 1114 | 4.79 / 73.15 | 5 | 147 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 16 | 15.24 | 463 | 113 | 0.11 / 63.61 | 5 | 5 |
2 | 7 | 2012.64 | 41 | 14.83 | 3486 | 2120 | 2.23 / 65.73 | 5 | 13 |
3 | 13 | 1320.08 | 20 | 14.96 | 2441 | 730 | 2.96 / 66.46 | 4 | 23 |
4 | 13 | 689.28 | 20 | 15.10 | 1478 | 446 | 3.41 / 66.90 | 5 | 25 |
5 | 13 | 173.08 | 20 | 15.24 | 636 | 194 | 3.60 / 67.10 | 5 | 19 |
6 | 13 | 63.76 | 20 | 15.27 | 448 | 137 | 3.74 / 67.23 | 5 | 16 |
7 | 8 | 0.16 | 225 | 15.24 | 329 | 1128 | 4.87 / 68.36 | 5 | 139 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 16 | 15.23 | 480 | 117 | 0.12 / 58.81 | 5 | 5 |
2 | 7 | 2012.76 | 40 | 14.85 | 3459 | 2055 | 2.17 / 60.87 | 5 | 15 |
3 | 13 | 1340.40 | 20 | 14.97 | 2424 | 726 | 2.90 / 61.59 | 5 | 20 |
4 | 13 | 740.80 | 20 | 15.09 | 1516 | 458 | 3.35 / 62.05 | 5 | 25 |
5 | 13 | 180.56 | 20 | 15.25 | 613 | 187 | 3.54 / 62.24 | 5 | 20 |
6 | 13 | 65.60 | 20 | 15.27 | 446 | 136 | 3.68 / 62.38 | 5 | 17 |
7 | 8 | 0.08 | 225 | 15.24 | 326 | 1118 | 4.80 / 63.49 | 5 | 131 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 16 | 15.24 | 471 | 115 | 0.11 / 54.01 | 5 | 5 |
2 | 7 | 2010.00 | 40 | 14.85 | 3466 | 2059 | 2.17 / 56.07 | 5 | 13 |
3 | 13 | 1318.52 | 20 | 14.97 | 2404 | 720 | 2.89 / 56.79 | 5 | 20 |
4 | 13 | 717.20 | 20 | 15.09 | 1498 | 452 | 3.35 / 57.24 | 5 | 26 |
5 | 13 | 156.20 | 20 | 15.25 | 604 | 184 | 3.53 / 57.43 | 5 | 20 |
6 | 13 | 46.00 | 20 | 15.27 | 409 | 125 | 3.65 / 57.55 | 5 | 18 |
7 | 8 | 0.08 | 225 | 15.23 | 334 | 1145 | 4.80 / 58.70 | 5 | 139 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 16 | 15.24 | 485 | 118 | 0.12 / 49.23 | 5 | 5 |
2 | 7 | 2007.80 | 41 | 14.85 | 3445 | 2097 | 2.22 / 51.32 | 5 | 15 |
3 | 13 | 1323.72 | 20 | 14.97 | 2436 | 729 | 2.95 / 52.05 | 5 | 21 |
4 | 13 | 716.88 | 20 | 15.09 | 1514 | 457 | 3.40 / 52.51 | 5 | 26 |
5 | 13 | 164.16 | 20 | 15.25 | 601 | 183 | 3.59 / 52.69 | 5 | 18 |
6 | 13 | 54.88 | 20 | 15.28 | 408 | 125 | 3.71 / 52.82 | 5 | 16 |
7 | 8 | 0.12 | 225 | 15.25 | 315 | 1081 | 4.79 / 53.90 | 5 | 144 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 16 | 15.24 | 468 | 114 | 0.11 / 44.31 | 5 | 5 |
2 | 7 | 2010.80 | 40 | 14.85 | 3482 | 2068 | 2.18 / 46.38 | 5 | 17 |
3 | 13 | 1410.36 | 20 | 14.95 | 2572 | 769 | 2.95 / 47.15 | 4 | 20 |
4 | 13 | 750.44 | 20 | 15.09 | 1563 | 472 | 3.42 / 47.62 | 5 | 26 |
5 | 13 | 189.84 | 20 | 15.24 | 677 | 206 | 3.63 / 47.83 | 5 | 20 |
6 | 13 | 78.48 | 20 | 15.27 | 471 | 144 | 3.77 / 47.97 | 5 | 17 |
7 | 8 | 0.12 | 227 | 15.24 | 328 | 1135 | 4.91 / 49.11 | 5 | 149 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 16 | 15.24 | 479 | 117 | 0.12 / 39.55 | 5 | 5 |
2 | 7 | 2012.68 | 40 | 14.85 | 3455 | 2052 | 2.17 / 41.60 | 5 | 15 |
3 | 13 | 1269.56 | 20 | 14.98 | 2350 | 704 | 2.87 / 42.31 | 4 | 23 |
4 | 13 | 681.12 | 20 | 15.10 | 1475 | 445 | 3.32 / 42.75 | 5 | 27 |
5 | 13 | 160.04 | 20 | 15.25 | 615 | 188 | 3.51 / 42.94 | 5 | 21 |
6 | 13 | 51.80 | 20 | 15.28 | 422 | 129 | 3.64 / 43.07 | 5 | 18 |
7 | 8 | 0.12 | 225 | 15.24 | 329 | 1128 | 4.76 / 44.20 | 5 | 141 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 16 | 15.25 | 467 | 114 | 0.11 / 34.74 | 5 | 5 |
2 | 7 | 2005.84 | 40 | 14.86 | 3458 | 2055 | 2.17 / 36.80 | 5 | 17 |
3 | 13 | 1362.12 | 20 | 14.97 | 2494 | 747 | 2.92 / 37.54 | 5 | 22 |
4 | 13 | 717.72 | 20 | 15.10 | 1526 | 461 | 3.38 / 38.00 | 5 | 27 |
5 | 13 | 158.76 | 20 | 15.26 | 595 | 182 | 3.56 / 38.19 | 5 | 21 |
6 | 13 | 49.64 | 20 | 15.28 | 411 | 126 | 3.68 / 38.31 | 5 | 18 |
7 | 8 | 0.08 | 227 | 15.25 | 325 | 1125 | 4.81 / 39.44 | 5 | 153 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 16 | 15.24 | 501 | 122 | 0.12 / 30.11 | 5 | 5 |
2 | 7 | 2003.68 | 40 | 14.86 | 3445 | 2048 | 2.17 / 32.15 | 5 | 15 |
3 | 13 | 1243.52 | 20 | 15.00 | 2287 | 686 | 2.86 / 32.84 | 4 | 23 |
4 | 13 | 685.16 | 20 | 15.12 | 1422 | 430 | 3.29 / 33.27 | 5 | 27 |
5 | 13 | 120.12 | 20 | 15.27 | 506 | 155 | 3.44 / 33.42 | 5 | 21 |
6 | 13 | 44.92 | 20 | 15.29 | 372 | 114 | 3.55 / 33.54 | 5 | 21 |
7 | 8 | 0.04 | 223 | 15.25 | 320 | 1088 | 4.64 / 34.63 | 5 | 139 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 16 | 15.24 | 492 | 120 | 0.12 / 25.40 | 5 | 5 |
2 | 7 | 2005.64 | 40 | 14.87 | 3440 | 2046 | 2.17 / 27.45 | 5 | 16 |
3 | 13 | 1273.04 | 20 | 15.00 | 2332 | 700 | 2.87 / 28.15 | 4 | 23 |
4 | 13 | 705.72 | 20 | 15.11 | 1464 | 442 | 3.31 / 28.59 | 5 | 29 |
5 | 13 | 103.96 | 20 | 15.27 | 492 | 150 | 3.46 / 28.74 | 5 | 24 |
6 | 13 | 32.48 | 20 | 15.29 | 365 | 112 | 3.57 / 28.85 | 5 | 22 |
7 | 8 | 0.04 | 223 | 15.24 | 333 | 1132 | 4.70 / 29.98 | 5 | 132 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 16 | 15.23 | 505 | 123 | 0.12 / 20.61 | 5 | 5 |
2 | 7 | 2009.16 | 40 | 14.87 | 3475 | 2067 | 2.19 / 22.68 | 5 | 16 |
3 | 13 | 1362.08 | 20 | 14.98 | 2494 | 747 | 2.94 / 23.43 | 4 | 23 |
4 | 13 | 714.60 | 20 | 15.10 | 1526 | 461 | 3.40 / 23.89 | 5 | 29 |
5 | 13 | 78.84 | 20 | 15.28 | 470 | 144 | 3.54 / 24.03 | 5 | 25 |
6 | 13 | 22.72 | 20 | 15.29 | 373 | 114 | 3.66 / 24.15 | 5 | 24 |
7 | 8 | 0.00 | 225 | 15.24 | 331 | 1135 | 4.79 / 25.28 | 5 | 153 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 16 | 15.25 | 471 | 115 | 0.11 / 15.73 | 5 | 5 |
2 | 7 | 2010.32 | 40 | 14.88 | 3457 | 2058 | 2.17 / 17.79 | 5 | 16 |
3 | 13 | 1379.60 | 20 | 14.97 | 2536 | 759 | 2.93 / 18.55 | 5 | 23 |
4 | 13 | 684.04 | 20 | 15.11 | 1473 | 445 | 3.38 / 18.99 | 5 | 30 |
5 | 13 | 91.56 | 20 | 15.27 | 517 | 158 | 3.53 / 19.15 | 5 | 26 |
6 | 13 | 17.44 | 20 | 15.28 | 390 | 119 | 3.65 / 19.27 | 5 | 24 |
7 | 8 | -0.16 | 225 | 15.23 | 356 | 1220 | 4.87 / 20.49 | 5 | 142 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 15 | 15.24 | 484 | 111 | 0.11 / 11.08 | 5 | 5 |
2 | 7 | 2006.88 | 40 | 14.89 | 3438 | 2048 | 2.16 / 13.13 | 5 | 16 |
3 | 13 | 1306.40 | 20 | 14.99 | 2399 | 719 | 2.88 / 13.85 | 5 | 24 |
4 | 13 | 710.76 | 20 | 15.10 | 1497 | 452 | 3.33 / 14.30 | 5 | 29 |
5 | 13 | 80.72 | 20 | 15.28 | 444 | 136 | 3.47 / 14.44 | 5 | 24 |
6 | 13 | 24.76 | 20 | 15.29 | 356 | 109 | 3.57 / 14.55 | 5 | 23 |
7 | 8 | -0.04 | 223 | 15.25 | 315 | 1071 | 4.65 / 15.62 | 5 | 133 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 14 | 15.22 | 446 | 95 | 0.10 / 6.36 | 5 | 5 |
2 | 3 | 1543.44 | 1 | 15.10 | 2765 | 42 | 0.14 / 6.40 | 5 | 14 |
3 | 7 | 2009.16 | 40 | 14.89 | 3442 | 2050 | 2.19 / 8.45 | 14 | 17 |
4 | 13 | 1394.08 | 20 | 14.99 | 2519 | 755 | 2.94 / 9.20 | 5 | 23 |
5 | 13 | 667.16 | 20 | 15.13 | 1404 | 425 | 3.37 / 9.63 | 5 | 30 |
6 | 13 | 89.16 | 20 | 15.28 | 449 | 137 | 3.50 / 9.76 | 5 | 23 |
7 | 13 | 27.80 | 20 | 15.29 | 347 | 106 | 3.61 / 9.87 | 5 | 22 |
8 | 8 | 0.00 | 225 | 15.25 | 321 | 1101 | 4.71 / 10.97 | 5 | 142 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 18 | 15.45 | 448 | 125 | 0.12 / 1.71 | 5 | 5 |
2 | 3 | 1346.92 | -2 | 15.61 | 0 | 0 | 0.00 / 1.71 | 5 | 5 |
3 | 7 | 2008.72 | 40 | 14.87 | 3451 | 2053 | 2.18 / 3.76 | 5 | 16 |
4 | 13 | 1292.72 | 20 | 14.98 | 2368 | 709 | 2.89 / 4.47 | 5 | 24 |
5 | 13 | 719.64 | 20 | 15.09 | 1487 | 449 | 3.34 / 4.92 | 5 | 29 |
6 | 13 | 154.16 | 20 | 15.25 | 549 | 167 | 3.50 / 5.09 | 5 | 22 |
7 | 13 | 43.96 | 20 | 15.27 | 361 | 110 | 3.61 / 5.20 | 5 | 18 |
8 | 8 | 0.08 | 227 | 15.23 | 307 | 1061 | 4.67 / 6.26 | 5 | 146 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 89.52 | 18 | 15.60 | 401 | 113 | 0.11 / 0.11 | 5 | 5 |
2 | 7 | 104.44 | 40 | 15.58 | 439 | 274 | 0.39 / 0.39 | 5 | 6 |
3 | 13 | 121.80 | 20 | 15.56 | 455 | 142 | 0.53 / 0.53 | 5 | 7 |
4 | 13 | 93.00 | 20 | 15.55 | 415 | 129 | 0.66 / 0.66 | 5 | 7 |
5 | 8 | 0.12 | 233 | 15.52 | 257 | 929 | 1.59 / 1.59 | 5 | 151 |
Average= | 1.59 (KJ/cycle) |