SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 18 | 15.03 | 448 | 121 | 0.12 / 462.39 | 6 | 6 |
2 | 7 | 1964.48 | 40 | 14.67 | 2866 | 1682 | 1.80 / 464.07 | 6 | 20 |
3 | 13 | 1432.96 | 20 | 14.72 | 2207 | 650 | 2.45 / 464.72 | 5 | 22 |
4 | 13 | 792.44 | 20 | 14.84 | 1406 | 417 | 2.87 / 465.14 | 5 | 25 |
5 | 13 | 106.08 | 20 | 15.05 | 468 | 141 | 3.01 / 465.28 | 5 | 23 |
6 | 13 | 34.04 | 20 | 15.07 | 370 | 112 | 3.12 / 465.39 | 5 | 22 |
7 | 8 | -0.08 | 272 | 15.02 | 312 | 1275 | 4.40 / 466.67 | 6 | 131 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 18 | 15.03 | 439 | 119 | 0.12 / 457.89 | 6 | 6 |
2 | 7 | 2010.80 | 40 | 14.65 | 2940 | 1723 | 1.84 / 459.61 | 6 | 17 |
3 | 13 | 1462.00 | 20 | 14.71 | 2260 | 665 | 2.51 / 460.27 | 5 | 19 |
4 | 13 | 817.44 | 20 | 14.83 | 1436 | 426 | 2.93 / 460.70 | 5 | 25 |
5 | 13 | 124.20 | 20 | 15.04 | 502 | 151 | 3.08 / 460.85 | 5 | 22 |
6 | 13 | 26.12 | 20 | 15.07 | 366 | 110 | 3.19 / 460.96 | 5 | 20 |
7 | 8 | 0.12 | 276 | 15.02 | 316 | 1310 | 4.50 / 462.27 | 6 | 146 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 18 | 15.03 | 450 | 122 | 0.12 / 453.47 | 6 | 6 |
2 | 7 | 2011.52 | 40 | 14.66 | 2929 | 1718 | 1.84 / 455.19 | 6 | 18 |
3 | 13 | 1422.68 | 20 | 14.73 | 2200 | 648 | 2.49 / 455.84 | 5 | 22 |
4 | 13 | 779.88 | 20 | 14.84 | 1381 | 410 | 2.90 / 456.25 | 5 | 25 |
5 | 13 | 92.88 | 20 | 15.06 | 460 | 139 | 3.04 / 456.39 | 5 | 21 |
6 | 13 | 29.24 | 20 | 15.07 | 364 | 110 | 3.15 / 456.50 | 5 | 19 |
7 | 8 | 0.04 | 272 | 15.02 | 311 | 1271 | 4.42 / 457.77 | 6 | 132 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 18 | 15.03 | 430 | 116 | 0.12 / 448.98 | 6 | 6 |
2 | 7 | 2015.08 | 40 | 14.65 | 2933 | 1719 | 1.84 / 450.70 | 6 | 20 |
3 | 13 | 1431.12 | 20 | 14.72 | 2211 | 651 | 2.49 / 451.35 | 5 | 22 |
4 | 13 | 825.32 | 20 | 14.83 | 1457 | 432 | 2.92 / 451.78 | 5 | 30 |
5 | 13 | 123.32 | 20 | 15.05 | 507 | 153 | 3.07 / 451.94 | 5 | 23 |
6 | 13 | 27.44 | 20 | 15.07 | 367 | 111 | 3.18 / 452.05 | 5 | 21 |
7 | 8 | -0.08 | 274 | 15.02 | 317 | 1305 | 4.49 / 453.35 | 6 | 137 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 18 | 15.04 | 435 | 118 | 0.12 / 444.60 | 6 | 6 |
2 | 7 | 1939.24 | 41 | 14.68 | 2833 | 1705 | 1.82 / 446.31 | 6 | 17 |
3 | 13 | 1397.24 | 20 | 14.74 | 2176 | 641 | 2.46 / 446.95 | 5 | 21 |
4 | 13 | 755.52 | 20 | 14.85 | 1363 | 405 | 2.87 / 447.35 | 5 | 28 |
5 | 13 | 94.48 | 20 | 15.06 | 457 | 138 | 3.01 / 447.49 | 5 | 23 |
6 | 13 | 29.08 | 20 | 15.08 | 359 | 108 | 3.12 / 447.60 | 5 | 21 |
7 | 8 | 0.12 | 272 | 15.02 | 310 | 1266 | 4.38 / 448.87 | 6 | 136 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 18 | 15.03 | 435 | 118 | 0.12 / 440.19 | 6 | 6 |
2 | 7 | 1928.04 | 41 | 14.68 | 2818 | 1696 | 1.81 / 441.89 | 6 | 21 |
3 | 13 | 1424.96 | 20 | 14.74 | 2201 | 649 | 2.46 / 442.54 | 5 | 22 |
4 | 13 | 807.72 | 20 | 14.84 | 1414 | 420 | 2.88 / 442.96 | 5 | 26 |
5 | 13 | 104.84 | 20 | 15.06 | 470 | 142 | 3.02 / 443.10 | 5 | 22 |
6 | 13 | 30.52 | 20 | 15.08 | 363 | 109 | 3.13 / 443.21 | 5 | 23 |
7 | 8 | -0.04 | 272 | 15.03 | 312 | 1276 | 4.41 / 444.48 | 6 | 134 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 18 | 15.04 | 433 | 117 | 0.12 / 435.75 | 6 | 6 |
2 | 7 | 2010.52 | 40 | 14.66 | 2919 | 1712 | 1.83 / 437.46 | 6 | 19 |
3 | 13 | 1440.84 | 20 | 14.72 | 2243 | 660 | 2.49 / 438.12 | 5 | 21 |
4 | 13 | 804.36 | 20 | 14.84 | 1418 | 421 | 2.91 / 438.55 | 5 | 26 |
5 | 13 | 108.48 | 20 | 15.06 | 474 | 143 | 3.05 / 438.69 | 5 | 23 |
6 | 13 | 32.84 | 20 | 15.07 | 367 | 111 | 3.16 / 438.80 | 5 | 21 |
7 | 8 | 0.12 | 274 | 15.02 | 310 | 1276 | 4.44 / 440.07 | 6 | 133 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 18 | 15.04 | 440 | 119 | 0.12 / 431.50 | 6 | 6 |
2 | 7 | 1812.84 | 40 | 14.73 | 2676 | 1577 | 1.70 / 433.08 | 6 | 15 |
3 | 13 | 1404.80 | 20 | 14.76 | 2179 | 643 | 2.34 / 433.72 | 5 | 25 |
4 | 13 | 761.00 | 20 | 14.87 | 1355 | 403 | 2.74 / 434.12 | 5 | 25 |
5 | 13 | 97.08 | 20 | 15.07 | 454 | 137 | 2.88 / 434.26 | 5 | 22 |
6 | 13 | 14.92 | 20 | 15.09 | 341 | 103 | 2.98 / 434.36 | 5 | 21 |
7 | 8 | 0.04 | 272 | 15.03 | 311 | 1271 | 4.25 / 435.64 | 6 | 139 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 18 | 15.04 | 441 | 119 | 0.12 / 427.11 | 6 | 6 |
2 | 7 | 1893.52 | 40 | 14.70 | 2788 | 1639 | 1.76 / 428.75 | 6 | 15 |
3 | 13 | 1435.20 | 20 | 14.74 | 2229 | 657 | 2.42 / 429.41 | 5 | 20 |
4 | 13 | 825.84 | 20 | 14.84 | 1454 | 432 | 2.85 / 429.84 | 5 | 24 |
5 | 13 | 117.84 | 20 | 15.05 | 495 | 149 | 3.00 / 429.99 | 5 | 23 |
6 | 13 | 24.68 | 20 | 15.08 | 358 | 108 | 3.10 / 430.10 | 5 | 22 |
7 | 8 | 0.04 | 272 | 15.03 | 314 | 1284 | 4.39 / 431.38 | 6 | 135 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 18 | 15.04 | 429 | 116 | 0.12 / 422.77 | 6 | 6 |
2 | 7 | 1861.72 | 40 | 14.71 | 2742 | 1613 | 1.73 / 424.38 | 6 | 20 |
3 | 13 | 1414.36 | 20 | 14.74 | 2199 | 648 | 2.38 / 425.03 | 5 | 21 |
4 | 13 | 804.84 | 20 | 14.84 | 1434 | 426 | 2.80 / 425.46 | 5 | 28 |
5 | 13 | 72.92 | 20 | 15.07 | 435 | 131 | 2.93 / 425.59 | 5 | 23 |
6 | 13 | 28.08 | 20 | 15.08 | 368 | 111 | 3.05 / 425.70 | 5 | 19 |
7 | 8 | 0.00 | 272 | 15.03 | 317 | 1296 | 4.34 / 426.99 | 6 | 138 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 18 | 15.04 | 444 | 120 | 0.12 / 418.39 | 6 | 6 |
2 | 7 | 1890.76 | 41 | 14.70 | 2779 | 1675 | 1.80 / 420.07 | 6 | 18 |
3 | 13 | 1368.08 | 20 | 14.75 | 2133 | 629 | 2.42 / 420.70 | 5 | 20 |
4 | 13 | 801.40 | 20 | 14.85 | 1407 | 418 | 2.84 / 421.12 | 5 | 24 |
5 | 13 | 110.00 | 20 | 15.06 | 480 | 145 | 2.99 / 421.26 | 5 | 25 |
6 | 13 | 34.76 | 20 | 15.07 | 375 | 113 | 3.10 / 421.37 | 5 | 22 |
7 | 8 | 0.04 | 272 | 15.02 | 313 | 1279 | 4.38 / 422.65 | 6 | 140 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 18 | 15.04 | 432 | 117 | 0.12 / 413.92 | 6 | 6 |
2 | 7 | 2006.52 | 40 | 14.67 | 2915 | 1711 | 1.83 / 415.63 | 6 | 15 |
3 | 13 | 1457.04 | 20 | 14.73 | 2246 | 662 | 2.49 / 416.29 | 5 | 19 |
4 | 13 | 778.04 | 20 | 14.85 | 1393 | 414 | 2.90 / 416.71 | 5 | 28 |
5 | 13 | 93.16 | 20 | 15.06 | 474 | 143 | 3.05 / 416.85 | 5 | 22 |
6 | 13 | 33.44 | 20 | 15.07 | 377 | 114 | 3.16 / 416.96 | 5 | 21 |
7 | 8 | 0.08 | 272 | 15.02 | 321 | 1311 | 4.47 / 418.27 | 6 | 131 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 18 | 15.04 | 440 | 119 | 0.12 / 409.55 | 6 | 6 |
2 | 7 | 2008.92 | 40 | 14.67 | 2920 | 1713 | 1.83 / 411.27 | 6 | 22 |
3 | 13 | 1387.52 | 20 | 14.74 | 2147 | 633 | 2.47 / 411.90 | 5 | 22 |
4 | 13 | 750.16 | 20 | 14.86 | 1337 | 397 | 2.86 / 412.30 | 5 | 27 |
5 | 13 | 91.72 | 20 | 15.07 | 448 | 135 | 3.00 / 412.43 | 5 | 23 |
6 | 13 | 30.52 | 20 | 15.08 | 361 | 109 | 3.11 / 412.54 | 5 | 22 |
7 | 8 | 0.04 | 272 | 15.03 | 309 | 1263 | 4.37 / 413.80 | 6 | 138 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 18 | 15.05 | 428 | 116 | 0.12 / 405.10 | 6 | 6 |
2 | 7 | 2005.20 | 40 | 14.67 | 2910 | 1708 | 1.82 / 406.80 | 6 | 14 |
3 | 13 | 1452.88 | 20 | 14.73 | 2231 | 657 | 2.48 / 407.46 | 5 | 21 |
4 | 13 | 800.64 | 20 | 14.85 | 1419 | 421 | 2.90 / 407.88 | 5 | 29 |
5 | 13 | 111.76 | 20 | 15.06 | 483 | 145 | 3.05 / 408.03 | 5 | 22 |
6 | 13 | 36.84 | 20 | 15.08 | 378 | 114 | 3.16 / 408.14 | 5 | 22 |
7 | 8 | 0.00 | 272 | 15.03 | 316 | 1292 | 4.45 / 409.43 | 6 | 131 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 18 | 15.04 | 438 | 119 | 0.12 / 400.72 | 6 | 6 |
2 | 7 | 2012.64 | 40 | 14.67 | 2926 | 1717 | 1.84 / 402.44 | 6 | 16 |
3 | 13 | 1427.16 | 20 | 14.74 | 2212 | 652 | 2.49 / 403.09 | 5 | 26 |
4 | 13 | 751.20 | 20 | 14.87 | 1336 | 397 | 2.88 / 403.49 | 5 | 28 |
5 | 13 | 125.72 | 20 | 15.06 | 496 | 149 | 3.03 / 403.64 | 5 | 24 |
6 | 13 | 32.28 | 20 | 15.08 | 361 | 109 | 3.14 / 403.75 | 5 | 21 |
7 | 8 | 0.08 | 272 | 15.04 | 301 | 1231 | 4.37 / 404.98 | 6 | 138 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 18 | 15.05 | 441 | 119 | 0.12 / 396.31 | 6 | 6 |
2 | 7 | 2016.12 | 40 | 14.67 | 2923 | 1715 | 1.83 / 398.03 | 6 | 17 |
3 | 13 | 1435.84 | 20 | 14.73 | 2216 | 653 | 2.49 / 398.68 | 5 | 17 |
4 | 13 | 820.32 | 20 | 14.85 | 1429 | 424 | 2.91 / 399.10 | 5 | 28 |
5 | 13 | 120.68 | 20 | 15.06 | 487 | 147 | 3.06 / 399.25 | 5 | 20 |
6 | 13 | 30.00 | 20 | 15.09 | 354 | 107 | 3.17 / 399.36 | 5 | 22 |
7 | 8 | 0.12 | 274 | 15.04 | 303 | 1249 | 4.41 / 400.61 | 6 | 135 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 18 | 15.05 | 434 | 118 | 0.12 / 391.90 | 6 | 6 |
2 | 7 | 2016.20 | 40 | 14.67 | 2936 | 1723 | 1.84 / 393.63 | 6 | 16 |
3 | 13 | 1424.96 | 20 | 14.73 | 2205 | 650 | 2.49 / 394.27 | 5 | 23 |
4 | 13 | 785.84 | 20 | 14.86 | 1384 | 411 | 2.90 / 394.69 | 5 | 28 |
5 | 13 | 129.52 | 20 | 15.06 | 509 | 153 | 3.05 / 394.84 | 5 | 23 |
6 | 13 | 30.20 | 20 | 15.09 | 355 | 107 | 3.16 / 394.95 | 6 | 19 |
7 | 8 | 0.00 | 274 | 15.04 | 302 | 1245 | 4.41 / 396.19 | 6 | 138 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 18 | 15.06 | 430 | 117 | 0.12 / 387.48 | 6 | 6 |
2 | 7 | 2009.00 | 40 | 14.67 | 2928 | 1718 | 1.83 / 389.19 | 6 | 18 |
3 | 13 | 1447.40 | 20 | 14.73 | 2236 | 659 | 2.49 / 389.85 | 5 | 19 |
4 | 13 | 806.72 | 20 | 14.86 | 1423 | 423 | 2.92 / 390.28 | 5 | 27 |
5 | 13 | 142.80 | 20 | 15.06 | 514 | 155 | 3.07 / 390.43 | 5 | 22 |
6 | 13 | 35.48 | 20 | 15.09 | 363 | 110 | 3.18 / 390.54 | 5 | 19 |
7 | 8 | 0.12 | 274 | 15.04 | 302 | 1245 | 4.43 / 391.78 | 6 | 130 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 18 | 15.07 | 427 | 116 | 0.12 / 383.05 | 6 | 6 |
2 | 7 | 2012.76 | 40 | 14.67 | 2930 | 1719 | 1.84 / 384.77 | 6 | 18 |
3 | 13 | 1419.80 | 20 | 14.74 | 2210 | 652 | 2.49 / 385.42 | 5 | 21 |
4 | 13 | 821.40 | 20 | 14.85 | 1451 | 431 | 2.92 / 385.85 | 5 | 28 |
5 | 13 | 154.00 | 20 | 15.06 | 546 | 164 | 3.08 / 386.02 | 5 | 21 |
6 | 13 | 35.36 | 20 | 15.09 | 357 | 108 | 3.19 / 386.13 | 6 | 18 |
7 | 8 | 0.12 | 274 | 15.05 | 299 | 1233 | 4.42 / 387.36 | 6 | 138 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 18 | 15.06 | 430 | 117 | 0.12 / 378.66 | 6 | 6 |
2 | 7 | 2009.24 | 40 | 14.67 | 2918 | 1712 | 1.83 / 380.37 | 6 | 17 |
3 | 13 | 1430.16 | 20 | 14.74 | 2204 | 650 | 2.48 / 381.02 | 5 | 21 |
4 | 13 | 827.52 | 20 | 14.86 | 1436 | 427 | 2.91 / 381.45 | 5 | 29 |
5 | 13 | 163.68 | 20 | 15.07 | 535 | 161 | 3.07 / 381.61 | 5 | 21 |
6 | 13 | 28.48 | 20 | 15.10 | 344 | 104 | 3.17 / 381.71 | 6 | 18 |
7 | 8 | 0.08 | 276 | 15.05 | 295 | 1225 | 4.40 / 382.94 | 6 | 148 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 18 | 15.06 | 439 | 119 | 0.12 / 374.25 | 6 | 6 |
2 | 7 | 2014.96 | 40 | 14.67 | 2930 | 1719 | 1.84 / 375.97 | 6 | 22 |
3 | 13 | 1466.24 | 20 | 14.74 | 2246 | 662 | 2.50 / 376.63 | 5 | 21 |
4 | 13 | 823.44 | 20 | 14.86 | 1452 | 432 | 2.93 / 377.06 | 5 | 24 |
5 | 13 | 160.80 | 20 | 15.07 | 536 | 162 | 3.09 / 377.22 | 5 | 20 |
6 | 13 | 26.92 | 20 | 15.10 | 342 | 103 | 3.20 / 377.32 | 6 | 17 |
7 | 8 | 0.08 | 274 | 15.06 | 295 | 1217 | 4.41 / 378.54 | 6 | 142 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 18 | 15.07 | 433 | 117 | 0.12 / 369.79 | 6 | 6 |
2 | 7 | 2006.12 | 41 | 14.67 | 2913 | 1752 | 1.87 / 371.55 | 6 | 20 |
3 | 13 | 1452.96 | 20 | 14.75 | 2233 | 659 | 2.53 / 372.20 | 5 | 20 |
4 | 13 | 803.20 | 20 | 14.87 | 1406 | 418 | 2.95 / 372.62 | 5 | 27 |
5 | 13 | 139.44 | 20 | 15.07 | 519 | 156 | 3.10 / 372.78 | 5 | 20 |
6 | 13 | 29.04 | 20 | 15.11 | 351 | 106 | 3.21 / 372.89 | 6 | 17 |
7 | 8 | 0.08 | 274 | 15.05 | 301 | 1241 | 4.45 / 374.13 | 6 | 137 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 18 | 15.07 | 431 | 117 | 0.12 / 365.41 | 6 | 6 |
2 | 7 | 2013.04 | 40 | 14.68 | 2932 | 1722 | 1.84 / 367.14 | 6 | 14 |
3 | 13 | 1418.00 | 20 | 14.76 | 2191 | 647 | 2.49 / 367.78 | 5 | 20 |
4 | 13 | 781.84 | 20 | 14.88 | 1376 | 409 | 2.89 / 368.19 | 5 | 25 |
5 | 13 | 161.76 | 20 | 15.07 | 534 | 161 | 3.06 / 368.35 | 5 | 21 |
6 | 13 | 23.96 | 20 | 15.11 | 339 | 102 | 3.16 / 368.46 | 6 | 17 |
7 | 8 | 0.04 | 274 | 15.06 | 296 | 1221 | 4.38 / 369.68 | 6 | 130 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 18 | 15.08 | 419 | 114 | 0.11 / 361.00 | 6 | 6 |
2 | 7 | 2006.00 | 41 | 14.68 | 2914 | 1754 | 1.87 / 362.75 | 6 | 20 |
3 | 13 | 1417.72 | 20 | 14.75 | 2193 | 647 | 2.51 / 363.40 | 5 | 21 |
4 | 13 | 809.08 | 20 | 14.87 | 1416 | 421 | 2.94 / 363.82 | 5 | 27 |
5 | 13 | 140.80 | 20 | 15.08 | 511 | 154 | 3.09 / 363.98 | 5 | 21 |
6 | 13 | 30.04 | 20 | 15.11 | 348 | 105 | 3.19 / 364.08 | 6 | 17 |
7 | 8 | 0.08 | 272 | 15.06 | 297 | 1217 | 4.41 / 365.30 | 6 | 132 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 18 | 15.07 | 430 | 117 | 0.12 / 356.59 | 6 | 6 |
2 | 7 | 2009.28 | 40 | 14.69 | 2916 | 1713 | 1.83 / 358.31 | 6 | 21 |
3 | 13 | 1455.92 | 20 | 14.75 | 2233 | 659 | 2.49 / 358.96 | 5 | 19 |
4 | 13 | 840.24 | 20 | 14.87 | 1453 | 432 | 2.92 / 359.40 | 5 | 25 |
5 | 13 | 169.16 | 20 | 15.07 | 545 | 164 | 3.09 / 359.56 | 5 | 21 |
6 | 13 | 24.84 | 20 | 15.11 | 340 | 103 | 3.19 / 359.66 | 5 | 17 |
7 | 8 | 0.00 | 274 | 15.06 | 296 | 1221 | 4.41 / 360.89 | 6 | 140 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 18 | 15.08 | 426 | 116 | 0.12 / 352.18 | 6 | 6 |
2 | 7 | 2009.20 | 40 | 14.69 | 2921 | 1716 | 1.83 / 353.90 | 6 | 22 |
3 | 13 | 1458.16 | 20 | 14.75 | 2246 | 663 | 2.49 / 354.56 | 5 | 23 |
4 | 13 | 846.60 | 20 | 14.87 | 1462 | 435 | 2.93 / 355.00 | 5 | 25 |
5 | 13 | 176.80 | 20 | 15.08 | 553 | 167 | 3.10 / 355.16 | 5 | 20 |
6 | 13 | 27.44 | 20 | 15.11 | 345 | 104 | 3.20 / 355.27 | 5 | 17 |
7 | 8 | 0.08 | 272 | 15.07 | 295 | 1209 | 4.41 / 356.48 | 6 | 135 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 18 | 15.08 | 429 | 116 | 0.12 / 347.76 | 6 | 6 |
2 | 7 | 2014.16 | 40 | 14.69 | 2931 | 1722 | 1.84 / 349.48 | 6 | 21 |
3 | 13 | 1469.36 | 20 | 14.75 | 2260 | 667 | 2.51 / 350.15 | 5 | 21 |
4 | 13 | 821.04 | 20 | 14.88 | 1435 | 427 | 2.93 / 350.57 | 5 | 30 |
5 | 13 | 191.48 | 20 | 15.07 | 579 | 175 | 3.11 / 350.75 | 5 | 22 |
6 | 13 | 30.64 | 20 | 15.11 | 347 | 105 | 3.21 / 350.85 | 5 | 17 |
7 | 8 | 0.12 | 272 | 15.07 | 296 | 1213 | 4.43 / 352.07 | 6 | 130 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 18 | 15.08 | 424 | 115 | 0.12 / 343.37 | 6 | 6 |
2 | 7 | 2007.92 | 40 | 14.69 | 2923 | 1718 | 1.83 / 345.09 | 6 | 16 |
3 | 13 | 1459.04 | 20 | 14.76 | 2244 | 662 | 2.50 / 345.75 | 5 | 21 |
4 | 13 | 781.12 | 20 | 14.90 | 1372 | 409 | 2.90 / 346.16 | 5 | 24 |
5 | 13 | 162.28 | 20 | 15.09 | 534 | 161 | 3.07 / 346.32 | 5 | 21 |
6 | 13 | 22.08 | 20 | 15.12 | 334 | 101 | 3.17 / 346.42 | 5 | 18 |
7 | 8 | 0.00 | 274 | 15.07 | 295 | 1218 | 4.38 / 347.64 | 6 | 134 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 18 | 15.08 | 426 | 116 | 0.12 / 338.95 | 6 | 6 |
2 | 7 | 2004.40 | 40 | 14.69 | 2919 | 1715 | 1.83 / 340.67 | 6 | 21 |
3 | 13 | 1452.12 | 20 | 14.76 | 2240 | 661 | 2.49 / 341.33 | 5 | 21 |
4 | 13 | 809.24 | 20 | 14.89 | 1422 | 423 | 2.92 / 341.75 | 5 | 27 |
5 | 13 | 181.40 | 20 | 15.08 | 568 | 171 | 3.09 / 341.92 | 5 | 24 |
6 | 13 | 25.88 | 20 | 15.12 | 348 | 105 | 3.19 / 342.03 | 5 | 17 |
7 | 8 | 0.08 | 272 | 15.07 | 300 | 1230 | 4.42 / 343.26 | 6 | 130 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 18 | 15.08 | 426 | 116 | 0.12 / 334.54 | 6 | 6 |
2 | 7 | 2004.00 | 40 | 14.70 | 2925 | 1720 | 1.84 / 336.26 | 6 | 19 |
3 | 13 | 1448.20 | 20 | 14.77 | 2224 | 657 | 2.49 / 336.91 | 5 | 20 |
4 | 13 | 801.56 | 20 | 14.89 | 1408 | 419 | 2.91 / 337.33 | 5 | 28 |
5 | 13 | 167.00 | 20 | 15.08 | 552 | 166 | 3.08 / 337.50 | 5 | 23 |
6 | 13 | 22.56 | 20 | 15.12 | 340 | 103 | 3.18 / 337.60 | 5 | 19 |
7 | 8 | 0.00 | 274 | 15.07 | 299 | 1235 | 4.42 / 338.84 | 6 | 142 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 18 | 15.08 | 432 | 117 | 0.12 / 330.15 | 6 | 6 |
2 | 7 | 2015.24 | 40 | 14.70 | 2928 | 1722 | 1.84 / 331.87 | 6 | 18 |
3 | 13 | 1429.60 | 20 | 14.77 | 2201 | 650 | 2.49 / 332.52 | 5 | 21 |
4 | 13 | 791.44 | 20 | 14.90 | 1387 | 413 | 2.90 / 332.94 | 5 | 25 |
5 | 13 | 163.04 | 20 | 15.09 | 535 | 161 | 3.06 / 333.10 | 5 | 22 |
6 | 13 | 21.64 | 20 | 15.13 | 336 | 102 | 3.17 / 333.20 | 5 | 19 |
7 | 8 | 0.16 | 272 | 15.08 | 297 | 1218 | 4.38 / 334.42 | 6 | 135 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 18 | 15.09 | 426 | 116 | 0.12 / 325.75 | 6 | 6 |
2 | 7 | 2012.36 | 40 | 14.70 | 2933 | 1725 | 1.84 / 327.47 | 6 | 17 |
3 | 13 | 1406.08 | 20 | 14.77 | 2191 | 647 | 2.49 / 328.12 | 5 | 20 |
4 | 13 | 803.32 | 20 | 14.90 | 1409 | 420 | 2.91 / 328.54 | 5 | 25 |
5 | 13 | 140.96 | 20 | 15.10 | 511 | 154 | 3.06 / 328.69 | 5 | 21 |
6 | 13 | 28.44 | 20 | 15.13 | 349 | 106 | 3.17 / 328.80 | 5 | 18 |
7 | 8 | 0.20 | 274 | 15.08 | 299 | 1235 | 4.40 / 330.04 | 6 | 141 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 18 | 15.09 | 431 | 117 | 0.12 / 321.34 | 6 | 6 |
2 | 7 | 2011.72 | 40 | 14.71 | 2920 | 1718 | 1.84 / 323.06 | 6 | 18 |
3 | 13 | 1432.84 | 20 | 14.78 | 2221 | 657 | 2.49 / 323.72 | 5 | 19 |
4 | 13 | 815.72 | 20 | 14.90 | 1427 | 425 | 2.92 / 324.14 | 5 | 25 |
5 | 13 | 148.20 | 20 | 15.10 | 518 | 156 | 3.07 / 324.30 | 5 | 22 |
6 | 13 | 19.96 | 20 | 15.14 | 337 | 102 | 3.18 / 324.40 | 6 | 18 |
7 | 8 | 0.08 | 274 | 15.08 | 298 | 1231 | 4.41 / 325.63 | 6 | 138 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 18 | 15.10 | 426 | 116 | 0.12 / 316.92 | 6 | 6 |
2 | 7 | 2009.28 | 41 | 14.70 | 2925 | 1763 | 1.88 / 318.68 | 6 | 21 |
3 | 13 | 1412.16 | 20 | 14.78 | 2188 | 647 | 2.53 / 319.33 | 5 | 27 |
4 | 13 | 765.84 | 20 | 14.91 | 1360 | 406 | 2.93 / 319.73 | 5 | 25 |
5 | 13 | 169.68 | 20 | 15.10 | 551 | 166 | 3.10 / 319.90 | 5 | 22 |
6 | 13 | 20.08 | 20 | 15.13 | 340 | 103 | 3.20 / 320.00 | 5 | 18 |
7 | 8 | 0.00 | 270 | 15.08 | 301 | 1226 | 4.43 / 321.23 | 6 | 134 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 18 | 15.10 | 427 | 116 | 0.12 / 312.47 | 6 | 6 |
2 | 7 | 2015.00 | 41 | 14.70 | 2922 | 1761 | 1.88 / 314.23 | 6 | 13 |
3 | 13 | 1488.92 | 20 | 14.77 | 2278 | 673 | 2.55 / 314.90 | 5 | 22 |
4 | 13 | 753.52 | 20 | 14.92 | 1359 | 406 | 2.96 / 315.31 | 5 | 23 |
5 | 13 | 167.60 | 20 | 15.10 | 548 | 165 | 3.12 / 315.47 | 5 | 20 |
6 | 13 | 19.80 | 20 | 15.14 | 334 | 101 | 3.22 / 315.57 | 6 | 16 |
7 | 8 | 0.16 | 272 | 15.09 | 299 | 1227 | 4.45 / 316.80 | 6 | 140 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 18 | 15.10 | 424 | 115 | 0.12 / 308.09 | 6 | 6 |
2 | 7 | 2011.44 | 40 | 14.72 | 2919 | 1719 | 1.83 / 309.81 | 6 | 17 |
3 | 13 | 1486.12 | 20 | 14.78 | 2273 | 672 | 2.51 / 310.48 | 5 | 21 |
4 | 13 | 792.92 | 20 | 14.92 | 1386 | 414 | 2.92 / 310.89 | 5 | 25 |
5 | 13 | 175.72 | 20 | 15.11 | 551 | 167 | 3.09 / 311.06 | 5 | 20 |
6 | 8 | 0.08 | 293 | 15.10 | 292 | 1292 | 4.38 / 312.35 | 6 | 145 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 18 | 15.10 | 427 | 116 | 0.12 / 303.70 | 6 | 6 |
2 | 7 | 2011.80 | 40 | 14.71 | 2919 | 1718 | 1.83 / 305.42 | 6 | 17 |
3 | 13 | 1427.72 | 20 | 14.79 | 2205 | 652 | 2.49 / 306.07 | 5 | 19 |
4 | 13 | 829.20 | 20 | 14.91 | 1443 | 430 | 2.92 / 306.50 | 5 | 27 |
5 | 13 | 162.84 | 20 | 15.11 | 538 | 163 | 3.08 / 306.66 | 5 | 19 |
6 | 13 | 18.24 | 20 | 15.15 | 331 | 100 | 3.18 / 306.76 | 6 | 16 |
7 | 8 | 0.12 | 272 | 15.10 | 295 | 1212 | 4.39 / 307.97 | 6 | 130 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 18 | 15.11 | 433 | 118 | 0.12 / 299.28 | 6 | 6 |
2 | 7 | 2008.72 | 40 | 14.71 | 2932 | 1725 | 1.84 / 301.01 | 6 | 16 |
3 | 13 | 1466.40 | 20 | 14.78 | 2259 | 668 | 2.51 / 301.67 | 5 | 20 |
4 | 13 | 819.00 | 20 | 14.92 | 1438 | 429 | 2.94 / 302.10 | 5 | 29 |
5 | 13 | 185.92 | 20 | 15.11 | 575 | 174 | 3.11 / 302.28 | 5 | 19 |
6 | 8 | 0.00 | 293 | 15.10 | 295 | 1305 | 4.42 / 303.58 | 6 | 140 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 18 | 15.11 | 427 | 116 | 0.12 / 294.87 | 6 | 6 |
2 | 7 | 2007.60 | 40 | 14.72 | 2915 | 1716 | 1.83 / 296.59 | 6 | 16 |
3 | 13 | 1421.60 | 20 | 14.80 | 2206 | 653 | 2.49 / 297.24 | 5 | 26 |
4 | 13 | 851.40 | 20 | 14.91 | 1466 | 437 | 2.92 / 297.68 | 5 | 26 |
5 | 13 | 180.24 | 20 | 15.11 | 569 | 172 | 3.09 / 297.85 | 5 | 19 |
6 | 8 | 0.12 | 293 | 15.11 | 296 | 1310 | 4.41 / 299.16 | 6 | 141 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 18 | 15.11 | 429 | 117 | 0.12 / 290.45 | 6 | 6 |
2 | 7 | 2014.40 | 40 | 14.72 | 2929 | 1725 | 1.84 / 292.17 | 6 | 20 |
3 | 13 | 1500.72 | 20 | 14.78 | 2298 | 679 | 2.52 / 292.85 | 5 | 24 |
4 | 13 | 842.16 | 20 | 14.92 | 1473 | 440 | 2.96 / 293.29 | 5 | 30 |
5 | 13 | 174.56 | 20 | 15.12 | 560 | 169 | 3.13 / 293.46 | 5 | 18 |
6 | 8 | 0.12 | 293 | 15.12 | 293 | 1298 | 4.43 / 294.76 | 6 | 143 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 18 | 15.11 | 428 | 116 | 0.12 / 286.02 | 6 | 6 |
2 | 7 | 2003.84 | 41 | 14.72 | 2924 | 1765 | 1.88 / 287.78 | 6 | 18 |
3 | 13 | 1444.60 | 20 | 14.81 | 2217 | 657 | 2.54 / 288.44 | 5 | 21 |
4 | 13 | 830.96 | 20 | 14.93 | 1437 | 429 | 2.97 / 288.87 | 5 | 26 |
5 | 13 | 183.96 | 20 | 15.12 | 563 | 170 | 3.14 / 289.04 | 5 | 21 |
6 | 8 | 0.08 | 291 | 15.12 | 294 | 1294 | 4.43 / 290.33 | 6 | 135 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 18 | 15.11 | 432 | 117 | 0.12 / 281.66 | 6 | 6 |
2 | 7 | 2008.40 | 40 | 14.73 | 2916 | 1718 | 1.84 / 283.38 | 6 | 20 |
3 | 13 | 1406.32 | 20 | 14.82 | 2177 | 645 | 2.48 / 284.03 | 5 | 22 |
4 | 13 | 777.64 | 20 | 14.94 | 1395 | 417 | 2.90 / 284.44 | 5 | 27 |
5 | 13 | 155.44 | 20 | 15.13 | 529 | 160 | 3.06 / 284.60 | 5 | 21 |
6 | 8 | 0.04 | 289 | 15.12 | 297 | 1298 | 4.36 / 285.90 | 6 | 131 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 18 | 15.11 | 440 | 120 | 0.12 / 277.24 | 6 | 6 |
2 | 7 | 2008.84 | 41 | 14.73 | 2916 | 1761 | 1.88 / 279.00 | 6 | 19 |
3 | 13 | 1449.60 | 20 | 14.81 | 2237 | 663 | 2.54 / 279.66 | 5 | 20 |
4 | 13 | 762.96 | 20 | 14.94 | 1378 | 412 | 2.96 / 280.07 | 5 | 25 |
5 | 13 | 130.12 | 20 | 15.13 | 501 | 152 | 3.11 / 280.23 | 5 | 24 |
6 | 8 | 0.20 | 287 | 15.11 | 304 | 1318 | 4.42 / 281.54 | 6 | 135 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 18 | 15.12 | 433 | 118 | 0.12 / 272.86 | 6 | 6 |
2 | 7 | 2015.48 | 40 | 14.73 | 2927 | 1725 | 1.84 / 274.59 | 6 | 19 |
3 | 13 | 1420.68 | 20 | 14.82 | 2191 | 649 | 2.49 / 275.24 | 5 | 21 |
4 | 13 | 782.00 | 20 | 14.95 | 1385 | 414 | 2.91 / 275.65 | 5 | 28 |
5 | 13 | 152.76 | 20 | 15.13 | 522 | 158 | 3.06 / 275.81 | 5 | 22 |
6 | 8 | -0.12 | 291 | 15.12 | 298 | 1311 | 4.38 / 277.12 | 6 | 137 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 18 | 15.11 | 453 | 123 | 0.12 / 268.44 | 6 | 6 |
2 | 7 | 2013.44 | 40 | 14.73 | 2940 | 1732 | 1.86 / 270.17 | 6 | 22 |
3 | 13 | 1467.48 | 20 | 14.81 | 2257 | 669 | 2.52 / 270.84 | 5 | 21 |
4 | 13 | 781.80 | 20 | 14.95 | 1386 | 414 | 2.94 / 271.25 | 5 | 28 |
5 | 13 | 199.08 | 20 | 15.12 | 591 | 179 | 3.12 / 271.43 | 5 | 22 |
6 | 8 | 0.12 | 291 | 15.12 | 299 | 1316 | 4.43 / 272.74 | 6 | 139 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 18 | 15.13 | 432 | 118 | 0.12 / 263.96 | 6 | 6 |
2 | 7 | 2007.76 | 40 | 14.74 | 2920 | 1722 | 1.84 / 265.68 | 6 | 18 |
3 | 13 | 1451.44 | 20 | 14.81 | 2239 | 663 | 2.50 / 266.34 | 5 | 22 |
4 | 13 | 799.80 | 20 | 14.95 | 1395 | 417 | 2.92 / 266.76 | 5 | 24 |
5 | 13 | 169.08 | 20 | 15.13 | 566 | 171 | 3.09 / 266.93 | 5 | 20 |
6 | 8 | 0.00 | 293 | 15.12 | 312 | 1382 | 4.47 / 268.31 | 6 | 143 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 18 | 15.12 | 444 | 121 | 0.12 / 259.55 | 6 | 6 |
2 | 7 | 2015.44 | 40 | 14.74 | 2916 | 1719 | 1.84 / 261.27 | 6 | 20 |
3 | 13 | 1457.68 | 20 | 14.82 | 2236 | 663 | 2.50 / 261.93 | 5 | 25 |
4 | 13 | 844.40 | 20 | 14.94 | 1463 | 437 | 2.94 / 262.37 | 5 | 24 |
5 | 13 | 178.16 | 20 | 15.14 | 554 | 168 | 3.11 / 262.54 | 5 | 20 |
6 | 8 | 0.04 | 291 | 15.13 | 296 | 1303 | 4.41 / 263.84 | 6 | 142 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 18 | 15.11 | 448 | 122 | 0.12 / 255.07 | 6 | 6 |
2 | 7 | 2004.52 | 40 | 14.74 | 2919 | 1721 | 1.84 / 256.79 | 6 | 17 |
3 | 13 | 1490.16 | 20 | 14.81 | 2285 | 677 | 2.52 / 257.47 | 5 | 19 |
4 | 13 | 901.40 | 20 | 14.92 | 1533 | 457 | 2.98 / 257.93 | 5 | 28 |
5 | 13 | 140.36 | 20 | 15.15 | 516 | 156 | 3.13 / 258.08 | 5 | 20 |
6 | 8 | 0.20 | 293 | 15.13 | 303 | 1343 | 4.48 / 259.43 | 6 | 146 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 18 | 15.13 | 432 | 118 | 0.12 / 250.61 | 6 | 6 |
2 | 7 | 2014.72 | 40 | 14.74 | 2922 | 1723 | 1.84 / 252.33 | 6 | 20 |
3 | 13 | 1425.40 | 20 | 14.83 | 2199 | 652 | 2.49 / 252.98 | 5 | 20 |
4 | 13 | 753.80 | 20 | 14.96 | 1363 | 408 | 2.90 / 253.39 | 5 | 27 |
5 | 13 | 130.44 | 20 | 15.15 | 513 | 155 | 3.06 / 253.54 | 5 | 22 |
6 | 8 | 0.12 | 291 | 15.12 | 320 | 1408 | 4.46 / 254.95 | 6 | 134 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 18 | 15.11 | 446 | 121 | 0.12 / 246.20 | 6 | 6 |
2 | 7 | 2015.96 | 40 | 14.75 | 2925 | 1726 | 1.85 / 247.93 | 6 | 19 |
3 | 13 | 1401.72 | 20 | 14.84 | 2162 | 642 | 2.49 / 248.57 | 5 | 25 |
4 | 13 | 830.08 | 20 | 14.95 | 1442 | 431 | 2.92 / 249.00 | 5 | 26 |
5 | 13 | 150.92 | 20 | 15.15 | 528 | 160 | 3.08 / 249.16 | 5 | 22 |
6 | 8 | -0.04 | 291 | 15.13 | 301 | 1325 | 4.41 / 250.49 | 6 | 143 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 18 | 15.13 | 437 | 119 | 0.12 / 241.79 | 6 | 7 |
2 | 7 | 2016.36 | 40 | 14.75 | 2919 | 1722 | 1.84 / 243.51 | 7 | 15 |
3 | 13 | 1418.16 | 20 | 14.83 | 2203 | 653 | 2.49 / 244.16 | 5 | 21 |
4 | 13 | 729.52 | 20 | 14.97 | 1326 | 397 | 2.89 / 244.56 | 5 | 25 |
5 | 13 | 135.04 | 20 | 15.15 | 512 | 155 | 3.05 / 244.71 | 5 | 22 |
6 | 8 | 0.12 | 289 | 15.13 | 313 | 1369 | 4.42 / 246.08 | 5 | 132 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 18 | 15.12 | 446 | 121 | 0.12 / 237.38 | 6 | 6 |
2 | 7 | 2003.52 | 40 | 14.76 | 2907 | 1716 | 1.84 / 239.10 | 6 | 22 |
3 | 13 | 1407.52 | 20 | 14.84 | 2171 | 644 | 2.48 / 239.75 | 5 | 21 |
4 | 13 | 800.24 | 20 | 14.96 | 1421 | 425 | 2.91 / 240.17 | 5 | 25 |
5 | 13 | 120.84 | 20 | 15.16 | 493 | 149 | 3.06 / 240.32 | 5 | 23 |
6 | 8 | 0.00 | 289 | 15.13 | 308 | 1347 | 4.40 / 241.67 | 5 | 143 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 18 | 15.12 | 429 | 117 | 0.12 / 232.93 | 6 | 6 |
2 | 7 | 2010.32 | 40 | 14.75 | 2924 | 1725 | 1.84 / 234.65 | 6 | 18 |
3 | 13 | 1450.24 | 20 | 14.84 | 2230 | 662 | 2.50 / 235.32 | 5 | 29 |
4 | 13 | 795.12 | 20 | 14.97 | 1392 | 417 | 2.92 / 235.73 | 5 | 26 |
5 | 13 | 101.16 | 20 | 15.16 | 483 | 146 | 3.07 / 235.88 | 5 | 22 |
6 | 8 | 0.08 | 287 | 15.13 | 319 | 1385 | 4.45 / 237.26 | 5 | 131 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 18 | 15.13 | 432 | 118 | 0.12 / 228.51 | 6 | 6 |
2 | 7 | 2015.68 | 40 | 14.75 | 2923 | 1725 | 1.84 / 230.23 | 6 | 17 |
3 | 13 | 1454.76 | 20 | 14.83 | 2236 | 663 | 2.51 / 230.89 | 5 | 22 |
4 | 13 | 833.60 | 20 | 14.95 | 1456 | 435 | 2.94 / 231.33 | 5 | 28 |
5 | 13 | 111.88 | 20 | 15.17 | 476 | 144 | 3.09 / 231.47 | 5 | 22 |
6 | 8 | 0.04 | 289 | 15.13 | 306 | 1338 | 4.42 / 232.81 | 5 | 135 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 18 | 15.14 | 437 | 119 | 0.12 / 224.10 | 6 | 6 |
2 | 7 | 2004.08 | 40 | 14.76 | 2896 | 1710 | 1.83 / 225.81 | 6 | 16 |
3 | 13 | 1439.00 | 20 | 14.84 | 2211 | 656 | 2.49 / 226.46 | 5 | 27 |
4 | 13 | 856.24 | 20 | 14.96 | 1469 | 440 | 2.92 / 226.90 | 5 | 25 |
5 | 13 | 169.84 | 20 | 15.16 | 544 | 165 | 3.09 / 227.07 | 5 | 21 |
6 | 8 | 0.16 | 291 | 15.14 | 300 | 1322 | 4.41 / 228.39 | 5 | 139 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 18 | 15.14 | 435 | 119 | 0.12 / 219.75 | 6 | 6 |
2 | 7 | 2004.00 | 40 | 14.76 | 2913 | 1720 | 1.84 / 221.47 | 6 | 15 |
3 | 13 | 1436.36 | 20 | 14.84 | 2211 | 656 | 2.49 / 222.12 | 5 | 23 |
4 | 13 | 735.60 | 20 | 14.99 | 1321 | 396 | 2.89 / 222.52 | 5 | 25 |
5 | 13 | 161.28 | 20 | 15.17 | 530 | 161 | 3.05 / 222.68 | 5 | 21 |
6 | 8 | 0.20 | 289 | 15.15 | 296 | 1296 | 4.35 / 223.98 | 6 | 132 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 18 | 15.14 | 433 | 118 | 0.12 / 215.37 | 6 | 6 |
2 | 7 | 2004.88 | 41 | 14.76 | 2901 | 1756 | 1.87 / 217.13 | 6 | 15 |
3 | 13 | 1348.60 | 20 | 14.87 | 2092 | 622 | 2.50 / 217.75 | 5 | 20 |
4 | 13 | 786.72 | 20 | 14.97 | 1390 | 416 | 2.91 / 218.16 | 5 | 27 |
5 | 13 | 180.08 | 20 | 15.16 | 557 | 169 | 3.08 / 218.33 | 5 | 23 |
6 | 8 | 0.04 | 289 | 15.15 | 296 | 1296 | 4.38 / 219.63 | 6 | 143 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 18 | 15.13 | 437 | 119 | 0.12 / 211.01 | 6 | 6 |
2 | 7 | 2004.00 | 40 | 14.77 | 2899 | 1713 | 1.83 / 212.72 | 6 | 15 |
3 | 13 | 1459.80 | 20 | 14.85 | 2243 | 666 | 2.50 / 213.39 | 5 | 21 |
4 | 13 | 796.52 | 20 | 14.98 | 1393 | 417 | 2.92 / 213.80 | 5 | 25 |
5 | 13 | 99.80 | 20 | 15.19 | 447 | 136 | 3.05 / 213.94 | 5 | 22 |
6 | 8 | 0.04 | 289 | 15.15 | 300 | 1314 | 4.36 / 215.25 | 6 | 133 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 18 | 15.14 | 436 | 119 | 0.12 / 206.58 | 6 | 6 |
2 | 7 | 2004.88 | 40 | 14.77 | 2908 | 1718 | 1.84 / 208.30 | 6 | 17 |
3 | 13 | 1493.20 | 20 | 14.85 | 2292 | 681 | 2.52 / 208.98 | 5 | 20 |
4 | 13 | 761.24 | 20 | 14.99 | 1361 | 408 | 2.93 / 209.39 | 5 | 26 |
5 | 13 | 105.40 | 20 | 15.18 | 471 | 143 | 3.07 / 209.53 | 5 | 23 |
6 | 8 | 0.12 | 289 | 15.14 | 310 | 1356 | 4.43 / 210.89 | 5 | 133 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 18 | 15.15 | 426 | 116 | 0.12 / 202.20 | 6 | 6 |
2 | 7 | 2014.92 | 40 | 14.77 | 2910 | 1719 | 1.84 / 203.92 | 6 | 17 |
3 | 13 | 1394.04 | 20 | 14.87 | 2150 | 639 | 2.47 / 204.56 | 5 | 23 |
4 | 13 | 828.00 | 20 | 14.96 | 1448 | 433 | 2.91 / 204.99 | 5 | 24 |
5 | 13 | 106.64 | 20 | 15.18 | 466 | 141 | 3.05 / 205.13 | 5 | 24 |
6 | 8 | 0.20 | 287 | 15.15 | 306 | 1331 | 4.38 / 206.46 | 6 | 131 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 18 | 15.15 | 425 | 116 | 0.12 / 197.83 | 6 | 6 |
2 | 7 | 2008.52 | 40 | 14.77 | 2917 | 1723 | 1.84 / 199.56 | 6 | 20 |
3 | 13 | 1444.40 | 20 | 14.86 | 2212 | 657 | 2.50 / 200.22 | 5 | 23 |
4 | 13 | 763.16 | 20 | 14.99 | 1354 | 406 | 2.90 / 200.62 | 5 | 30 |
5 | 13 | 68.60 | 20 | 15.19 | 414 | 126 | 3.03 / 200.75 | 5 | 22 |
6 | 8 | 0.04 | 289 | 15.16 | 305 | 1336 | 4.36 / 202.08 | 6 | 140 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 18 | 15.16 | 430 | 117 | 0.12 / 193.46 | 6 | 6 |
2 | 7 | 2014.84 | 40 | 14.77 | 2918 | 1724 | 1.84 / 195.19 | 6 | 18 |
3 | 13 | 1420.56 | 20 | 14.86 | 2184 | 649 | 2.49 / 195.84 | 5 | 24 |
4 | 13 | 798.44 | 20 | 14.98 | 1403 | 420 | 2.91 / 196.26 | 5 | 27 |
5 | 13 | 117.84 | 20 | 15.18 | 480 | 146 | 3.06 / 196.40 | 5 | 23 |
6 | 8 | 0.12 | 289 | 15.16 | 300 | 1314 | 4.37 / 197.72 | 6 | 139 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 18 | 15.15 | 435 | 119 | 0.12 / 189.03 | 6 | 6 |
2 | 7 | 2014.96 | 40 | 14.77 | 2923 | 1727 | 1.85 / 190.76 | 6 | 17 |
3 | 13 | 1398.24 | 20 | 14.86 | 2177 | 647 | 2.49 / 191.40 | 5 | 22 |
4 | 13 | 902.28 | 20 | 14.95 | 1536 | 459 | 2.95 / 191.86 | 5 | 25 |
5 | 13 | 127.56 | 20 | 15.18 | 500 | 152 | 3.10 / 192.02 | 5 | 22 |
6 | 13 | 21.80 | 20 | 15.21 | 341 | 104 | 3.21 / 192.12 | 5 | 20 |
7 | 8 | -0.04 | 270 | 15.16 | 300 | 1228 | 4.44 / 193.35 | 6 | 135 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 18 | 15.17 | 428 | 117 | 0.12 / 184.55 | 6 | 6 |
2 | 7 | 2014.24 | 40 | 14.77 | 2921 | 1726 | 1.84 / 186.28 | 6 | 17 |
3 | 13 | 1422.48 | 20 | 14.87 | 2191 | 652 | 2.49 / 186.93 | 5 | 20 |
4 | 13 | 829.96 | 20 | 14.98 | 1439 | 431 | 2.93 / 187.36 | 5 | 26 |
5 | 13 | 138.68 | 20 | 15.17 | 530 | 161 | 3.09 / 187.52 | 5 | 23 |
6 | 13 | 14.84 | 20 | 15.21 | 345 | 105 | 3.19 / 187.62 | 5 | 20 |
7 | 8 | 0.08 | 270 | 15.15 | 315 | 1289 | 4.48 / 188.91 | 6 | 138 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 18 | 15.16 | 426 | 116 | 0.12 / 180.20 | 6 | 6 |
2 | 7 | 2014.64 | 40 | 14.78 | 2919 | 1726 | 1.84 / 181.93 | 6 | 18 |
3 | 13 | 1390.80 | 20 | 14.88 | 2152 | 640 | 2.48 / 182.57 | 5 | 24 |
4 | 13 | 783.96 | 20 | 14.99 | 1382 | 414 | 2.90 / 182.98 | 5 | 27 |
5 | 13 | 129.76 | 20 | 15.19 | 485 | 147 | 3.04 / 183.13 | 5 | 18 |
6 | 13 | 32.48 | 20 | 15.22 | 344 | 105 | 3.15 / 183.23 | 6 | 16 |
7 | 8 | 0.16 | 272 | 15.17 | 291 | 1201 | 4.35 / 184.43 | 6 | 146 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 18 | 15.17 | 410 | 112 | 0.11 / 175.82 | 6 | 6 |
2 | 7 | 2013.52 | 40 | 14.78 | 2916 | 1724 | 1.84 / 177.54 | 6 | 18 |
3 | 13 | 1404.72 | 20 | 14.88 | 2179 | 648 | 2.48 / 178.19 | 5 | 22 |
4 | 13 | 803.08 | 20 | 14.99 | 1400 | 420 | 2.90 / 178.61 | 5 | 26 |
5 | 13 | 132.60 | 20 | 15.19 | 494 | 150 | 3.05 / 178.76 | 5 | 21 |
6 | 13 | 25.84 | 20 | 15.22 | 341 | 104 | 3.16 / 178.87 | 6 | 19 |
7 | 8 | -0.08 | 270 | 15.17 | 297 | 1216 | 4.37 / 180.08 | 6 | 141 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 18 | 15.18 | 412 | 113 | 0.11 / 171.41 | 6 | 6 |
2 | 7 | 2015.24 | 40 | 14.77 | 2920 | 1725 | 1.84 / 173.14 | 6 | 16 |
3 | 13 | 1458.40 | 20 | 14.86 | 2238 | 665 | 2.50 / 173.80 | 5 | 29 |
4 | 13 | 797.56 | 20 | 14.99 | 1400 | 420 | 2.92 / 174.22 | 5 | 26 |
5 | 13 | 206.72 | 20 | 15.17 | 596 | 181 | 3.10 / 174.40 | 5 | 24 |
6 | 13 | 86.96 | 20 | 15.20 | 420 | 128 | 3.23 / 174.53 | 5 | 19 |
7 | 8 | 0.04 | 270 | 15.17 | 288 | 1180 | 4.41 / 175.71 | 6 | 132 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 18 | 15.19 | 426 | 116 | 0.12 / 167.07 | 6 | 6 |
2 | 7 | 2011.16 | 40 | 14.78 | 2917 | 1725 | 1.84 / 168.79 | 6 | 19 |
3 | 13 | 1380.72 | 20 | 14.89 | 2140 | 637 | 2.48 / 169.43 | 5 | 24 |
4 | 13 | 745.44 | 20 | 15.01 | 1327 | 398 | 2.88 / 169.83 | 5 | 27 |
5 | 13 | 162.92 | 20 | 15.19 | 536 | 163 | 3.04 / 169.99 | 5 | 20 |
6 | 13 | 52.88 | 20 | 15.22 | 371 | 113 | 3.15 / 170.11 | 6 | 17 |
7 | 8 | -0.08 | 270 | 15.18 | 291 | 1193 | 4.35 / 171.30 | 6 | 132 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 18 | 15.17 | 437 | 119 | 0.12 / 162.69 | 6 | 6 |
2 | 7 | 2003.88 | 40 | 14.79 | 2905 | 1719 | 1.84 / 164.41 | 6 | 17 |
3 | 13 | 1378.76 | 20 | 14.89 | 2148 | 640 | 2.48 / 165.05 | 5 | 22 |
4 | 13 | 800.84 | 20 | 15.00 | 1413 | 424 | 2.90 / 165.47 | 5 | 25 |
5 | 13 | 166.08 | 20 | 15.19 | 550 | 167 | 3.07 / 165.64 | 5 | 22 |
6 | 13 | 25.72 | 20 | 15.23 | 340 | 104 | 3.17 / 165.74 | 6 | 17 |
7 | 8 | 0.08 | 270 | 15.18 | 295 | 1209 | 4.38 / 166.95 | 6 | 130 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 18 | 15.18 | 424 | 116 | 0.12 / 158.31 | 6 | 6 |
2 | 7 | 2012.80 | 40 | 14.79 | 2911 | 1722 | 1.84 / 160.04 | 6 | 15 |
3 | 13 | 1427.96 | 20 | 14.88 | 2211 | 658 | 2.50 / 160.69 | 5 | 22 |
4 | 13 | 809.16 | 20 | 15.00 | 1425 | 427 | 2.92 / 161.12 | 5 | 25 |
5 | 13 | 129.84 | 20 | 15.20 | 496 | 151 | 3.07 / 161.27 | 5 | 22 |
6 | 8 | 0.12 | 289 | 15.18 | 296 | 1299 | 4.37 / 162.57 | 6 | 129 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 18 | 15.18 | 429 | 117 | 0.12 / 153.98 | 6 | 6 |
2 | 7 | 2017.48 | 40 | 14.79 | 2918 | 1726 | 1.84 / 155.71 | 6 | 16 |
3 | 13 | 1361.20 | 20 | 14.89 | 2134 | 636 | 2.48 / 156.34 | 5 | 21 |
4 | 13 | 762.52 | 20 | 15.01 | 1364 | 409 | 2.89 / 156.75 | 5 | 27 |
5 | 13 | 101.28 | 20 | 15.21 | 451 | 137 | 3.03 / 156.89 | 5 | 21 |
6 | 13 | 15.60 | 20 | 15.23 | 326 | 99 | 3.12 / 156.99 | 6 | 19 |
7 | 8 | -0.04 | 270 | 15.18 | 295 | 1209 | 4.33 / 158.20 | 6 | 135 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 18 | 15.18 | 425 | 116 | 0.12 / 149.57 | 6 | 6 |
2 | 7 | 2010.76 | 40 | 14.79 | 2909 | 1721 | 1.84 / 151.29 | 6 | 17 |
3 | 13 | 1451.72 | 20 | 14.88 | 2241 | 667 | 2.50 / 151.96 | 5 | 21 |
4 | 13 | 839.04 | 20 | 14.99 | 1459 | 437 | 2.94 / 152.39 | 5 | 27 |
5 | 13 | 117.32 | 20 | 15.21 | 476 | 145 | 3.09 / 152.54 | 5 | 22 |
6 | 13 | 17.76 | 20 | 15.23 | 331 | 101 | 3.19 / 152.64 | 5 | 20 |
7 | 8 | 0.04 | 270 | 15.18 | 299 | 1225 | 4.41 / 153.86 | 6 | 140 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 18 | 15.18 | 407 | 111 | 0.11 / 145.19 | 6 | 6 |
2 | 7 | 2014.40 | 40 | 14.79 | 2923 | 1729 | 1.84 / 146.92 | 6 | 15 |
3 | 13 | 1460.68 | 20 | 14.88 | 2247 | 669 | 2.51 / 147.59 | 5 | 24 |
4 | 13 | 772.24 | 20 | 15.01 | 1367 | 410 | 2.92 / 148.00 | 5 | 25 |
5 | 13 | 106.96 | 20 | 15.21 | 460 | 140 | 3.06 / 148.14 | 5 | 22 |
6 | 13 | 15.64 | 20 | 15.23 | 329 | 100 | 3.16 / 148.24 | 5 | 20 |
7 | 8 | 0.16 | 267 | 15.18 | 299 | 1212 | 4.37 / 149.45 | 6 | 134 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 18 | 15.20 | 403 | 110 | 0.11 / 140.80 | 6 | 6 |
2 | 7 | 2004.84 | 40 | 14.80 | 2902 | 1718 | 1.83 / 142.52 | 6 | 22 |
3 | 13 | 1407.44 | 20 | 14.89 | 2183 | 650 | 2.48 / 143.17 | 5 | 24 |
4 | 13 | 802.04 | 20 | 15.01 | 1405 | 422 | 2.90 / 143.59 | 5 | 26 |
5 | 13 | 173.84 | 20 | 15.19 | 557 | 169 | 3.07 / 143.76 | 5 | 24 |
6 | 13 | 50.08 | 20 | 15.23 | 373 | 114 | 3.18 / 143.87 | 6 | 20 |
7 | 8 | -0.04 | 270 | 15.18 | 295 | 1209 | 4.39 / 145.08 | 6 | 140 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 18 | 15.20 | 409 | 112 | 0.11 / 136.49 | 6 | 6 |
2 | 7 | 2006.04 | 40 | 14.80 | 2911 | 1723 | 1.84 / 138.22 | 6 | 15 |
3 | 13 | 1346.72 | 20 | 14.91 | 2101 | 627 | 2.46 / 138.84 | 5 | 20 |
4 | 13 | 752.36 | 20 | 15.03 | 1338 | 402 | 2.86 / 139.24 | 5 | 26 |
5 | 13 | 163.44 | 20 | 15.21 | 529 | 161 | 3.02 / 139.40 | 5 | 20 |
6 | 13 | 59.76 | 20 | 15.23 | 375 | 114 | 3.14 / 139.52 | 6 | 16 |
7 | 8 | 0.20 | 270 | 15.20 | 285 | 1170 | 4.31 / 140.69 | 6 | 133 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 18 | 15.20 | 417 | 114 | 0.11 / 132.11 | 6 | 6 |
2 | 7 | 2003.72 | 40 | 14.80 | 2910 | 1723 | 1.84 / 133.83 | 6 | 16 |
3 | 13 | 1404.12 | 20 | 14.90 | 2187 | 652 | 2.49 / 134.49 | 5 | 22 |
4 | 13 | 801.08 | 20 | 15.02 | 1419 | 426 | 2.91 / 134.91 | 5 | 28 |
5 | 13 | 178.52 | 20 | 15.21 | 564 | 172 | 3.09 / 135.08 | 5 | 17 |
6 | 13 | 75.92 | 20 | 15.23 | 400 | 122 | 3.21 / 135.21 | 6 | 16 |
7 | 8 | 0.00 | 272 | 15.20 | 284 | 1174 | 4.38 / 136.38 | 6 | 137 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 18 | 15.20 | 407 | 111 | 0.11 / 127.74 | 6 | 6 |
2 | 7 | 2013.80 | 40 | 14.81 | 2924 | 1732 | 1.84 / 129.47 | 6 | 18 |
3 | 13 | 1404.80 | 20 | 14.90 | 2176 | 648 | 2.49 / 130.12 | 5 | 20 |
4 | 13 | 799.20 | 20 | 15.03 | 1397 | 420 | 2.91 / 130.54 | 5 | 24 |
5 | 13 | 173.48 | 20 | 15.21 | 541 | 165 | 3.08 / 130.70 | 5 | 19 |
6 | 13 | 69.80 | 20 | 15.24 | 390 | 119 | 3.20 / 130.82 | 6 | 15 |
7 | 8 | 0.08 | 272 | 15.20 | 285 | 1178 | 4.37 / 132.00 | 6 | 143 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 18 | 15.20 | 431 | 118 | 0.12 / 123.34 | 6 | 6 |
2 | 7 | 2005.88 | 41 | 14.80 | 2917 | 1770 | 1.89 / 125.11 | 6 | 17 |
3 | 13 | 1371.16 | 20 | 14.91 | 2121 | 632 | 2.52 / 125.74 | 5 | 22 |
4 | 13 | 736.16 | 20 | 15.04 | 1327 | 399 | 2.92 / 126.14 | 5 | 26 |
5 | 13 | 151.36 | 20 | 15.22 | 524 | 160 | 3.08 / 126.30 | 5 | 20 |
6 | 13 | 45.52 | 20 | 15.24 | 366 | 112 | 3.19 / 126.41 | 6 | 17 |
7 | 8 | 0.08 | 270 | 15.20 | 295 | 1211 | 4.40 / 127.62 | 6 | 144 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 18 | 15.20 | 410 | 112 | 0.11 / 119.06 | 6 | 6 |
2 | 7 | 2008.24 | 40 | 14.81 | 2911 | 1724 | 1.84 / 120.79 | 6 | 19 |
3 | 13 | 1311.56 | 20 | 14.93 | 2055 | 614 | 2.45 / 121.40 | 5 | 23 |
4 | 13 | 749.20 | 20 | 15.04 | 1333 | 401 | 2.85 / 121.80 | 5 | 27 |
5 | 13 | 83.76 | 20 | 15.23 | 430 | 131 | 2.98 / 121.93 | 5 | 21 |
6 | 8 | 0.20 | 289 | 15.20 | 294 | 1291 | 4.27 / 123.22 | 6 | 139 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 18 | 15.22 | 402 | 110 | 0.11 / 114.71 | 6 | 6 |
2 | 7 | 2011.64 | 40 | 14.81 | 2919 | 1729 | 1.84 / 116.44 | 6 | 17 |
3 | 13 | 1446.64 | 20 | 14.90 | 2222 | 662 | 2.50 / 117.10 | 5 | 21 |
4 | 13 | 798.40 | 20 | 15.03 | 1401 | 421 | 2.92 / 117.52 | 5 | 27 |
5 | 13 | 129.00 | 20 | 15.23 | 483 | 147 | 3.07 / 117.67 | 5 | 18 |
6 | 13 | 34.12 | 20 | 15.25 | 342 | 104 | 3.17 / 117.77 | 6 | 16 |
7 | 8 | 0.16 | 270 | 15.21 | 286 | 1175 | 4.35 / 118.95 | 6 | 139 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 18 | 15.22 | 400 | 110 | 0.11 / 110.38 | 6 | 6 |
2 | 7 | 2004.04 | 40 | 14.82 | 2904 | 1721 | 1.83 / 112.10 | 6 | 18 |
3 | 13 | 1441.12 | 20 | 14.91 | 2221 | 662 | 2.49 / 112.76 | 5 | 21 |
4 | 13 | 762.00 | 20 | 15.05 | 1338 | 403 | 2.90 / 113.16 | 5 | 25 |
5 | 13 | 173.28 | 20 | 15.22 | 546 | 166 | 3.06 / 113.33 | 5 | 18 |
6 | 13 | 66.04 | 20 | 15.25 | 381 | 116 | 3.18 / 113.45 | 6 | 15 |
7 | 8 | 0.04 | 272 | 15.22 | 279 | 1155 | 4.33 / 114.60 | 6 | 137 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 18 | 15.22 | 412 | 113 | 0.11 / 105.97 | 6 | 6 |
2 | 7 | 2011.32 | 40 | 14.82 | 2917 | 1729 | 1.84 / 107.70 | 6 | 18 |
3 | 13 | 1450.12 | 20 | 14.91 | 2232 | 666 | 2.51 / 108.37 | 5 | 20 |
4 | 13 | 803.08 | 20 | 15.04 | 1418 | 427 | 2.93 / 108.79 | 5 | 28 |
5 | 13 | 195.96 | 20 | 15.22 | 590 | 180 | 3.11 / 108.97 | 5 | 17 |
6 | 13 | 89.08 | 20 | 15.25 | 413 | 126 | 3.24 / 109.10 | 6 | 15 |
7 | 8 | 0.04 | 272 | 15.22 | 282 | 1167 | 4.41 / 110.27 | 6 | 132 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 18 | 15.22 | 404 | 111 | 0.11 / 101.58 | 6 | 6 |
2 | 7 | 2018.00 | 40 | 14.82 | 2928 | 1736 | 1.85 / 103.31 | 6 | 15 |
3 | 13 | 1395.48 | 20 | 14.92 | 2163 | 645 | 2.49 / 103.96 | 5 | 23 |
4 | 13 | 829.48 | 20 | 15.03 | 1430 | 430 | 2.92 / 104.39 | 5 | 28 |
5 | 13 | 198.76 | 20 | 15.22 | 580 | 177 | 3.10 / 104.56 | 5 | 19 |
6 | 13 | 90.08 | 20 | 15.25 | 419 | 128 | 3.23 / 104.69 | 6 | 16 |
7 | 8 | 0.08 | 272 | 15.22 | 282 | 1167 | 4.39 / 105.86 | 6 | 134 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 18 | 15.21 | 426 | 117 | 0.12 / 97.21 | 6 | 6 |
2 | 7 | 2013.24 | 40 | 14.83 | 2929 | 1737 | 1.85 / 98.95 | 6 | 17 |
3 | 13 | 1398.04 | 20 | 14.93 | 2161 | 645 | 2.50 / 99.59 | 5 | 23 |
4 | 13 | 764.60 | 20 | 15.05 | 1350 | 406 | 2.91 / 100.00 | 5 | 25 |
5 | 13 | 184.76 | 20 | 15.23 | 552 | 168 | 3.07 / 100.17 | 5 | 19 |
6 | 13 | 78.20 | 20 | 15.25 | 401 | 122 | 3.20 / 100.29 | 6 | 16 |
7 | 8 | 0.12 | 272 | 15.22 | 284 | 1176 | 4.37 / 101.47 | 6 | 143 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 18 | 15.21 | 432 | 118 | 0.12 / 92.84 | 6 | 6 |
2 | 7 | 2003.68 | 40 | 14.84 | 2909 | 1727 | 1.85 / 94.56 | 6 | 14 |
3 | 13 | 1367.72 | 20 | 14.94 | 2121 | 634 | 2.48 / 95.20 | 5 | 21 |
4 | 13 | 802.24 | 20 | 15.04 | 1409 | 424 | 2.90 / 95.62 | 5 | 26 |
5 | 13 | 121.00 | 20 | 15.24 | 483 | 147 | 3.05 / 95.77 | 5 | 22 |
6 | 13 | 32.28 | 20 | 15.26 | 352 | 107 | 3.16 / 95.87 | 5 | 20 |
7 | 8 | 0.08 | 270 | 15.21 | 297 | 1220 | 4.38 / 97.09 | 6 | 138 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 18 | 15.22 | 427 | 117 | 0.12 / 88.42 | 6 | 6 |
2 | 7 | 2011.96 | 40 | 14.84 | 2912 | 1729 | 1.85 / 90.15 | 6 | 14 |
3 | 13 | 1408.76 | 20 | 14.93 | 2179 | 651 | 2.50 / 90.80 | 5 | 20 |
4 | 13 | 825.76 | 20 | 15.03 | 1457 | 438 | 2.93 / 91.24 | 5 | 27 |
5 | 13 | 133.28 | 20 | 15.23 | 509 | 155 | 3.09 / 91.39 | 5 | 22 |
6 | 13 | 33.76 | 20 | 15.26 | 351 | 107 | 3.20 / 91.50 | 5 | 20 |
7 | 8 | 0.08 | 270 | 15.21 | 296 | 1216 | 4.41 / 92.72 | 6 | 139 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 17 | 15.22 | 430 | 111 | 0.11 / 84.02 | 6 | 6 |
2 | 7 | 2008.72 | 40 | 14.84 | 2921 | 1734 | 1.85 / 85.76 | 7 | 14 |
3 | 13 | 1425.72 | 20 | 14.94 | 2200 | 657 | 2.50 / 86.42 | 5 | 21 |
4 | 13 | 799.68 | 20 | 15.05 | 1402 | 422 | 2.92 / 86.84 | 5 | 27 |
5 | 13 | 164.24 | 20 | 15.23 | 541 | 165 | 3.09 / 87.00 | 5 | 22 |
6 | 13 | 54.92 | 20 | 15.26 | 374 | 114 | 3.20 / 87.12 | 6 | 18 |
7 | 8 | 0.12 | 272 | 15.22 | 287 | 1188 | 4.39 / 88.31 | 6 | 145 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 17 | 15.22 | 401 | 104 | 0.10 / 79.61 | 6 | 6 |
2 | 7 | 2005.04 | 40 | 14.85 | 2915 | 1732 | 1.84 / 81.34 | 6 | 14 |
3 | 13 | 1354.56 | 20 | 14.95 | 2107 | 630 | 2.47 / 81.97 | 5 | 21 |
4 | 13 | 793.76 | 20 | 15.04 | 1412 | 425 | 2.89 / 82.39 | 5 | 26 |
5 | 13 | 150.64 | 20 | 15.23 | 536 | 163 | 3.05 / 82.56 | 5 | 22 |
6 | 13 | 49.04 | 20 | 15.26 | 381 | 116 | 3.17 / 82.67 | 6 | 19 |
7 | 8 | 0.08 | 270 | 15.21 | 302 | 1240 | 4.41 / 83.91 | 6 | 134 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 17 | 15.23 | 404 | 105 | 0.10 / 75.24 | 6 | 6 |
2 | 7 | 2014.88 | 40 | 14.85 | 2920 | 1734 | 1.84 / 76.97 | 6 | 14 |
3 | 13 | 1461.56 | 20 | 14.92 | 2248 | 671 | 2.51 / 77.64 | 5 | 20 |
4 | 13 | 765.00 | 20 | 15.06 | 1365 | 411 | 2.92 / 78.06 | 5 | 26 |
5 | 13 | 133.80 | 20 | 15.24 | 492 | 150 | 3.07 / 78.21 | 5 | 21 |
6 | 13 | 62.08 | 20 | 15.26 | 386 | 118 | 3.19 / 78.32 | 6 | 20 |
7 | 8 | 0.04 | 270 | 15.23 | 287 | 1180 | 4.37 / 79.50 | 6 | 139 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 17 | 15.24 | 403 | 104 | 0.10 / 70.88 | 6 | 6 |
2 | 7 | 2012.84 | 40 | 14.85 | 2933 | 1742 | 1.85 / 72.62 | 6 | 14 |
3 | 13 | 1425.80 | 20 | 14.94 | 2208 | 660 | 2.51 / 73.28 | 5 | 20 |
4 | 13 | 800.40 | 20 | 15.06 | 1398 | 421 | 2.93 / 73.70 | 5 | 26 |
5 | 13 | 127.32 | 20 | 15.25 | 480 | 146 | 3.07 / 73.85 | 5 | 21 |
6 | 13 | 62.96 | 20 | 15.26 | 385 | 118 | 3.19 / 73.96 | 6 | 19 |
7 | 8 | -0.04 | 270 | 15.23 | 285 | 1172 | 4.36 / 75.13 | 6 | 135 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 17 | 15.23 | 401 | 104 | 0.10 / 66.48 | 6 | 6 |
2 | 7 | 2008.32 | 40 | 14.85 | 2928 | 1739 | 1.84 / 68.22 | 6 | 14 |
3 | 13 | 1487.80 | 20 | 14.93 | 2288 | 683 | 2.53 / 68.90 | 5 | 19 |
4 | 13 | 812.96 | 20 | 15.06 | 1429 | 430 | 2.96 / 69.33 | 5 | 26 |
5 | 13 | 149.04 | 20 | 15.25 | 506 | 154 | 3.11 / 69.49 | 5 | 19 |
6 | 13 | 78.64 | 20 | 15.26 | 404 | 123 | 3.23 / 69.61 | 6 | 17 |
7 | 8 | 0.04 | 272 | 15.24 | 280 | 1161 | 4.39 / 70.77 | 6 | 139 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 17 | 15.24 | 394 | 102 | 0.10 / 62.12 | 6 | 6 |
2 | 7 | 2003.76 | 40 | 14.86 | 2908 | 1729 | 1.83 / 63.85 | 6 | 14 |
3 | 13 | 1373.28 | 20 | 14.96 | 2133 | 638 | 2.47 / 64.49 | 5 | 20 |
4 | 13 | 806.64 | 20 | 15.06 | 1414 | 426 | 2.89 / 64.92 | 5 | 26 |
5 | 13 | 177.36 | 20 | 15.24 | 545 | 166 | 3.06 / 65.08 | 5 | 20 |
6 | 13 | 65.24 | 20 | 15.27 | 383 | 117 | 3.18 / 65.20 | 6 | 17 |
7 | 8 | 0.08 | 272 | 15.24 | 284 | 1177 | 4.36 / 66.38 | 6 | 149 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 17 | 15.24 | 398 | 103 | 0.10 / 57.80 | 6 | 6 |
2 | 7 | 2008.44 | 40 | 14.86 | 2922 | 1737 | 1.84 / 59.53 | 6 | 13 |
3 | 13 | 1378.96 | 20 | 14.96 | 2140 | 640 | 2.48 / 60.17 | 5 | 20 |
4 | 13 | 773.68 | 20 | 15.07 | 1358 | 409 | 2.89 / 60.58 | 5 | 26 |
5 | 13 | 167.52 | 20 | 15.25 | 533 | 163 | 3.05 / 60.75 | 5 | 21 |
6 | 13 | 63.84 | 20 | 15.27 | 380 | 116 | 3.17 / 60.86 | 6 | 18 |
7 | 8 | 0.12 | 270 | 15.24 | 282 | 1160 | 4.33 / 62.02 | 6 | 132 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 17 | 15.24 | 408 | 106 | 0.11 / 53.46 | 6 | 6 |
2 | 7 | 2012.44 | 40 | 14.86 | 2921 | 1736 | 1.84 / 55.19 | 6 | 15 |
3 | 13 | 1388.64 | 20 | 14.95 | 2152 | 643 | 2.49 / 55.84 | 5 | 21 |
4 | 13 | 780.96 | 20 | 15.07 | 1370 | 413 | 2.90 / 56.25 | 5 | 26 |
5 | 13 | 108.12 | 20 | 15.26 | 454 | 139 | 3.04 / 56.39 | 5 | 21 |
6 | 13 | 38.00 | 20 | 15.28 | 351 | 107 | 3.14 / 56.49 | 6 | 19 |
7 | 13 | 11.12 | 20 | 15.28 | 311 | 95 | 3.24 / 56.59 | 6 | 19 |
8 | 8 | 0.08 | 250 | 15.23 | 290 | 1104 | 4.34 / 57.69 | 6 | 138 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 17 | 15.24 | 399 | 103 | 0.10 / 49.10 | 6 | 6 |
2 | 7 | 2008.08 | 40 | 14.87 | 2929 | 1742 | 1.85 / 50.85 | 6 | 14 |
3 | 13 | 1392.24 | 20 | 14.96 | 2171 | 650 | 2.50 / 51.50 | 5 | 21 |
4 | 13 | 748.96 | 20 | 15.08 | 1338 | 404 | 2.90 / 51.90 | 5 | 26 |
5 | 13 | 120.08 | 20 | 15.26 | 473 | 144 | 3.04 / 52.04 | 5 | 20 |
6 | 13 | 49.24 | 20 | 15.28 | 368 | 112 | 3.16 / 52.16 | 5 | 19 |
7 | 8 | 0.12 | 270 | 15.24 | 290 | 1193 | 4.35 / 53.35 | 6 | 133 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 17 | 15.23 | 406 | 105 | 0.11 / 44.76 | 6 | 6 |
2 | 7 | 2007.56 | 40 | 14.87 | 2921 | 1737 | 1.84 / 46.50 | 6 | 14 |
3 | 13 | 1442.36 | 20 | 14.96 | 2222 | 665 | 2.51 / 47.16 | 5 | 20 |
4 | 13 | 748.00 | 20 | 15.09 | 1327 | 400 | 2.91 / 47.56 | 5 | 26 |
5 | 13 | 156.44 | 20 | 15.26 | 520 | 159 | 3.07 / 47.72 | 5 | 22 |
6 | 13 | 49.20 | 20 | 15.28 | 361 | 110 | 3.18 / 47.83 | 6 | 18 |
7 | 8 | 0.12 | 270 | 15.25 | 284 | 1169 | 4.35 / 49.00 | 6 | 134 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 17 | 15.23 | 405 | 105 | 0.10 / 40.37 | 6 | 6 |
2 | 7 | 2012.28 | 40 | 14.87 | 2926 | 1740 | 1.85 / 42.11 | 6 | 14 |
3 | 13 | 1413.36 | 20 | 14.96 | 2187 | 654 | 2.50 / 42.77 | 5 | 20 |
4 | 13 | 754.92 | 20 | 15.08 | 1355 | 409 | 2.91 / 43.18 | 5 | 27 |
5 | 13 | 120.64 | 20 | 15.26 | 486 | 148 | 3.06 / 43.32 | 5 | 23 |
6 | 13 | 47.84 | 20 | 15.28 | 369 | 113 | 3.17 / 43.44 | 6 | 21 |
7 | 8 | -0.04 | 270 | 15.23 | 296 | 1217 | 4.39 / 44.65 | 6 | 141 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 17 | 15.24 | 395 | 102 | 0.10 / 36.02 | 6 | 6 |
2 | 7 | 2011.40 | 40 | 14.88 | 2923 | 1740 | 1.84 / 37.76 | 6 | 14 |
3 | 13 | 1412.40 | 20 | 14.97 | 2186 | 654 | 2.50 / 38.42 | 5 | 20 |
4 | 13 | 791.08 | 20 | 15.08 | 1383 | 417 | 2.91 / 38.83 | 5 | 26 |
5 | 13 | 144.88 | 20 | 15.26 | 503 | 154 | 3.07 / 38.99 | 5 | 22 |
6 | 13 | 39.92 | 20 | 15.28 | 352 | 108 | 3.17 / 39.10 | 6 | 19 |
7 | 8 | 0.16 | 270 | 15.24 | 285 | 1173 | 4.35 / 40.27 | 6 | 136 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 17 | 15.24 | 420 | 109 | 0.11 / 31.69 | 6 | 6 |
2 | 7 | 2004.16 | 40 | 14.89 | 2909 | 1733 | 1.84 / 33.42 | 6 | 15 |
3 | 13 | 1398.92 | 20 | 14.97 | 2165 | 648 | 2.49 / 34.07 | 5 | 22 |
4 | 13 | 815.12 | 20 | 15.07 | 1418 | 427 | 2.92 / 34.50 | 5 | 26 |
5 | 13 | 129.04 | 20 | 15.26 | 487 | 149 | 3.07 / 34.65 | 5 | 23 |
6 | 13 | 33.08 | 20 | 15.29 | 339 | 104 | 3.17 / 34.75 | 6 | 19 |
7 | 8 | 0.12 | 270 | 15.25 | 284 | 1169 | 4.34 / 35.92 | 6 | 136 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 17 | 15.24 | 426 | 110 | 0.11 / 27.37 | 6 | 6 |
2 | 7 | 2008.00 | 40 | 14.89 | 2917 | 1737 | 1.85 / 29.11 | 7 | 15 |
3 | 13 | 1346.40 | 20 | 14.98 | 2104 | 630 | 2.48 / 29.74 | 5 | 23 |
4 | 13 | 768.88 | 20 | 15.09 | 1363 | 411 | 2.89 / 30.15 | 5 | 27 |
5 | 13 | 85.92 | 20 | 15.27 | 432 | 132 | 3.02 / 30.28 | 5 | 24 |
6 | 13 | 14.60 | 20 | 15.29 | 328 | 100 | 3.12 / 30.38 | 5 | 22 |
7 | 8 | 0.04 | 267 | 15.24 | 295 | 1200 | 4.32 / 31.58 | 6 | 135 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 17 | 15.24 | 408 | 106 | 0.11 / 23.06 | 6 | 6 |
2 | 7 | 2004.40 | 40 | 14.89 | 2903 | 1729 | 1.83 / 24.79 | 6 | 15 |
3 | 13 | 1402.56 | 20 | 14.98 | 2165 | 649 | 2.48 / 25.44 | 5 | 22 |
4 | 13 | 757.36 | 20 | 15.09 | 1335 | 403 | 2.89 / 25.84 | 5 | 28 |
5 | 13 | 81.36 | 20 | 15.28 | 410 | 125 | 3.01 / 25.96 | 5 | 25 |
6 | 13 | 22.96 | 20 | 15.29 | 325 | 99 | 3.11 / 26.06 | 5 | 23 |
7 | 8 | 0.08 | 267 | 15.24 | 294 | 1196 | 4.31 / 27.26 | 6 | 137 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 17 | 15.25 | 386 | 100 | 0.10 / 18.80 | 6 | 6 |
2 | 7 | 2005.20 | 40 | 14.90 | 2905 | 1731 | 1.83 / 20.53 | 6 | 16 |
3 | 13 | 1397.44 | 20 | 14.98 | 2150 | 644 | 2.48 / 21.18 | 5 | 22 |
4 | 13 | 771.64 | 20 | 15.09 | 1343 | 405 | 2.88 / 21.58 | 5 | 28 |
5 | 13 | 129.04 | 20 | 15.27 | 471 | 144 | 3.02 / 21.73 | 5 | 24 |
6 | 13 | 29.48 | 20 | 15.29 | 325 | 99 | 3.12 / 21.82 | 6 | 21 |
7 | 8 | 2.44 | 270 | 15.25 | 274 | 1128 | 4.25 / 22.95 | 6 | 137 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 17 | 15.25 | 384 | 100 | 0.10 / 14.56 | 6 | 6 |
2 | 7 | 2013.60 | 40 | 14.90 | 2911 | 1735 | 1.83 / 16.30 | 6 | 16 |
3 | 13 | 1336.12 | 20 | 15.00 | 2078 | 623 | 2.46 / 16.92 | 5 | 22 |
4 | 13 | 736.12 | 20 | 15.11 | 1296 | 392 | 2.85 / 17.31 | 5 | 27 |
5 | 13 | 193.92 | 20 | 15.26 | 552 | 168 | 3.02 / 17.48 | 5 | 19 |
6 | 13 | 87.80 | 20 | 15.29 | 394 | 120 | 3.14 / 17.60 | 6 | 17 |
7 | 8 | 0.12 | 272 | 15.26 | 265 | 1100 | 4.24 / 18.70 | 6 | 146 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 17 | 15.25 | 387 | 100 | 0.10 / 10.30 | 6 | 6 |
2 | 7 | 2006.04 | 40 | 14.90 | 2909 | 1734 | 1.83 / 12.04 | 6 | 17 |
3 | 13 | 1359.32 | 20 | 14.99 | 2107 | 632 | 2.47 / 12.67 | 5 | 23 |
4 | 13 | 788.68 | 20 | 15.09 | 1373 | 414 | 2.88 / 13.08 | 5 | 27 |
5 | 13 | 181.92 | 20 | 15.26 | 540 | 165 | 3.04 / 13.25 | 5 | 21 |
6 | 13 | 66.00 | 20 | 15.29 | 369 | 113 | 3.16 / 13.36 | 6 | 19 |
7 | 8 | 0.12 | 270 | 15.26 | 267 | 1100 | 4.26 / 14.46 | 6 | 130 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 15 | 15.22 | 389 | 89 | 0.09 / 5.95 | 6 | 6 |
2 | 10 | 1501.76 | 3 | 15.07 | 2269 | 103 | 0.19 / 6.05 | 5 | 10 |
3 | 7 | 2005.80 | 40 | 14.91 | 2908 | 1734 | 1.93 / 7.78 | 10 | 17 |
4 | 13 | 1416.16 | 20 | 14.99 | 2167 | 650 | 2.58 / 8.43 | 5 | 24 |
5 | 13 | 756.08 | 20 | 15.10 | 1327 | 401 | 2.98 / 8.83 | 5 | 27 |
6 | 13 | 199.36 | 20 | 15.26 | 559 | 171 | 3.15 / 9.00 | 5 | 21 |
7 | 13 | 51.36 | 20 | 15.29 | 343 | 105 | 3.25 / 9.11 | 6 | 18 |
8 | 8 | 0.24 | 272 | 15.26 | 264 | 1096 | 4.35 / 10.20 | 6 | 144 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 18 | 15.44 | 365 | 101 | 0.10 / 1.72 | 6 | 6 |
2 | 3 | 1393.48 | -2 | 15.60 | 6 | 0 | 0.00 / 1.72 | 6 | 6 |
3 | 7 | 2007.72 | 41 | 14.89 | 2888 | 1763 | 1.86 / 3.48 | 6 | 17 |
4 | 13 | 1333.32 | 20 | 14.98 | 2079 | 623 | 2.49 / 4.10 | 5 | 24 |
5 | 13 | 729.88 | 20 | 15.09 | 1284 | 388 | 2.87 / 4.49 | 5 | 27 |
6 | 13 | 208.56 | 20 | 15.23 | 569 | 173 | 3.05 / 4.66 | 5 | 21 |
7 | 13 | 59.28 | 20 | 15.27 | 353 | 108 | 3.16 / 4.77 | 6 | 17 |
8 | 8 | 0.12 | 270 | 15.23 | 264 | 1086 | 4.24 / 5.86 | 6 | 133 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 141.72 | 18 | 15.60 | 426 | 120 | 0.12 / 0.12 | 6 | 6 |
2 | 7 | 155.08 | 40 | 15.58 | 436 | 272 | 0.39 / 0.39 | 6 | 6 |
3 | 13 | 158.72 | 20 | 15.56 | 439 | 137 | 0.53 / 0.53 | 6 | 6 |
4 | 13 | 98.28 | 20 | 15.55 | 362 | 113 | 0.64 / 0.64 | 6 | 6 |
5 | 8 | 0.12 | 278 | 15.51 | 226 | 974 | 1.61 / 1.61 | 6 | 144 |
Average= | 1.61 (KJ/cycle) |