SIO Argo Site:
Pump Diagnostics Page   



Serial= 3146 WMO= 3902288

Return

←PreviousNext→

Cycle 31 GMT 19/ 9/2023 2:46: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 29 15.20 465 205 0.20 / 116.63 2 2
2 7 2003.88 38 14.83 2954 1665 1.87 / 118.30 2 4
3 13 1224.28 18 14.99 1979 534 2.40 / 118.83 2 7
4 13 699.08 18 15.12 1290 351 2.75 / 119.18 2 8
5 13 195.04 18 15.26 594 163 2.92 / 119.34 2 9
6 8 0.04 165 15.27 304 766 3.68 / 120.11 2 12
Average= 3.75 (KJ/cycle)

Cycle 30 GMT 9/ 9/2023 7:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 15.20 448 197 0.20 / 112.89 2 2
2 7 2007.92 38 14.84 2956 1667 1.86 / 114.55 2 5
3 13 1285.24 18 15.00 2061 556 2.42 / 115.11 2 6
4 13 745.88 18 15.11 1350 367 2.79 / 115.48 2 8
5 13 226.44 18 15.26 643 177 2.96 / 115.65 2 8
6 8 0.00 165 15.27 306 771 3.74 / 116.43 2 11
Average= 3.76 (KJ/cycle)

Cycle 29 GMT 30/ 8/2023 12: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 29 15.22 449 198 0.20 / 109.18 2 3
2 7 2004.80 38 14.82 2950 1661 1.86 / 110.85 2 4
3 13 1339.64 18 14.96 2130 574 2.43 / 111.42 2 6
4 13 698.32 18 15.12 1294 352 2.79 / 111.77 2 8
5 13 156.76 18 15.28 540 149 2.93 / 111.92 2 7
6 8 0.20 165 15.25 306 770 3.70 / 112.69 2 5
Average= 3.76 (KJ/cycle)

Cycle 28 GMT 20/ 8/2023 16:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 29 15.21 472 208 0.21 / 105.44 2 3
2 7 2004.04 38 14.83 2961 1669 1.88 / 107.10 2 4
3 13 1325.76 18 14.99 2112 570 2.45 / 107.67 2 6
4 13 736.92 18 15.12 1345 366 2.81 / 108.04 2 8
5 13 180.28 18 15.27 582 160 2.97 / 108.20 2 7
6 8 0.16 165 15.27 312 786 3.76 / 108.99 2 14
Average= 3.76 (KJ/cycle)

Cycle 27 GMT 10/ 8/2023 21:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 29 15.21 444 196 0.20 / 101.68 2 2
2 7 2003.04 38 14.83 2942 1658 1.85 / 103.34 2 4
3 13 1237.68 18 15.01 1995 539 2.39 / 103.88 2 7
4 13 752.96 18 15.12 1368 372 2.77 / 104.25 2 8
5 13 228.08 18 15.26 656 180 2.95 / 104.43 2 8
6 8 0.04 165 15.28 317 799 3.74 / 105.23 2 13
Average= 3.76 (KJ/cycle)

Cycle 26 GMT 1/ 8/2023 2:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 15.23 457 202 0.20 / 98.01 2 2
2 7 2010.56 38 14.83 2949 1662 1.86 / 99.67 2 4
3 13 1243.40 18 15.00 1995 539 2.40 / 100.21 2 6
4 13 635.32 18 15.15 1206 329 2.73 / 100.54 2 8
5 13 194.64 18 15.26 599 165 2.90 / 100.70 2 8
6 8 0.12 165 15.26 309 778 3.67 / 101.48 2 12
Average= 3.76 (KJ/cycle)

Cycle 25 GMT 22/ 7/2023 7:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 29 15.22 468 207 0.21 / 94.28 2 2
2 7 2005.40 38 14.83 2951 1663 1.87 / 95.94 2 4
3 13 1346.64 18 14.98 2128 574 2.44 / 96.51 2 6
4 13 760.96 18 15.12 1370 373 2.82 / 96.89 2 8
5 13 162.12 18 15.28 555 153 2.97 / 97.04 2 7
6 8 0.12 165 15.28 306 771 3.74 / 97.81 2 15
Average= 3.76 (KJ/cycle)

Cycle 24 GMT 12/ 7/2023 11:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 29 15.21 468 206 0.21 / 90.49 2 2
2 7 2004.16 38 14.85 2948 1664 1.87 / 92.15 2 4
3 13 1293.64 18 14.99 2067 558 2.43 / 92.71 2 6
4 13 754.44 18 15.11 1369 372 2.80 / 93.08 2 8
5 13 270.96 18 15.26 715 196 3.00 / 93.28 2 8
6 8 0.00 165 15.28 313 789 3.79 / 94.07 2 12
Average= 3.76 (KJ/cycle)

Cycle 23 GMT 2/ 7/2023 16:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 29 15.23 465 205 0.21 / 86.70 2 2
2 7 2007.72 39 14.83 2958 1711 1.92 / 88.41 2 4
3 13 1342.16 18 14.99 2141 578 2.49 / 88.99 2 7
4 13 708.68 18 15.14 1309 357 2.85 / 89.35 2 8
5 13 151.08 18 15.28 540 149 3.00 / 89.49 2 7
6 8 0.12 165 15.28 313 789 3.79 / 90.28 2 16
Average= 3.76 (KJ/cycle)

Cycle 22 GMT 22/ 6/2023 20:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 29 15.23 475 210 0.21 / 82.94 2 2
2 7 2002.80 39 14.85 2946 1706 1.92 / 84.65 2 4
3 13 1298.12 18 15.00 2071 559 2.48 / 85.21 2 7
4 13 675.44 18 15.15 1261 344 2.82 / 85.55 2 8
5 13 174.80 18 15.28 574 158 2.98 / 85.71 2 7
6 8 0.04 165 15.28 311 784 3.76 / 86.49 2 11
Average= 3.76 (KJ/cycle)

Cycle 21 GMT 13/ 6/2023 1:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 28 15.25 472 202 0.20 / 79.02 2 2
2 7 2012.24 39 14.85 2978 1725 1.93 / 80.74 2 4
3 13 1394.40 18 14.98 2205 595 2.52 / 81.33 2 6
4 13 699.80 18 15.16 1300 355 2.88 / 81.69 2 8
5 13 193.88 18 15.29 606 167 3.04 / 81.86 2 7
6 13 19.80 18 15.32 349 96 3.14 / 81.95 2 5
7 8 0.08 165 15.28 310 782 3.92 / 82.73 2 11
Average= 3.76 (KJ/cycle)

Cycle 20 GMT 3/ 6/2023 6:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 15.23 460 196 0.20 / 75.29 2 2
2 7 2004.12 38 14.86 2966 1675 1.87 / 76.96 2 4
3 13 1327.76 18 15.00 2121 573 2.44 / 77.53 2 6
4 13 670.28 18 15.16 1266 345 2.79 / 77.88 2 8
5 13 138.04 18 15.31 521 144 2.93 / 78.02 2 7
6 8 0.12 165 15.29 314 792 3.72 / 78.81 2 8
Average= 3.75 (KJ/cycle)

Cycle 19 GMT 24/ 5/2023 10:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 28 15.22 462 197 0.20 / 71.43 2 2
2 7 2004.80 38 14.87 2963 1674 1.87 / 73.10 2 4
3 13 1342.76 18 15.02 2146 580 2.45 / 73.68 2 7
4 13 745.60 18 15.15 1366 373 2.82 / 74.05 2 8
5 13 152.84 18 15.31 543 150 2.97 / 74.20 2 7
6 13 24.52 18 15.31 357 98 3.07 / 74.30 2 8
7 8 0.04 165 15.27 312 786 3.86 / 75.09 2 13
Average= 3.75 (KJ/cycle)

Cycle 18 GMT 14/ 5/2023 15:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 28 15.25 472 202 0.20 / 67.75 2 2
2 7 2002.84 38 14.85 2956 1668 1.87 / 69.42 2 4
3 13 1189.32 18 15.04 1941 525 2.40 / 69.94 2 6
4 13 660.72 18 15.17 1256 343 2.74 / 70.29 2 8
5 13 161.92 18 15.30 558 154 2.89 / 70.44 2 7
6 8 0.16 165 15.29 314 792 3.68 / 71.23 2 8
Average= 3.75 (KJ/cycle)

Cycle 17 GMT 4/ 5/2023 19:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 28 15.24 474 202 0.20 / 63.85 2 2
2 7 2007.72 38 14.87 2962 1674 1.88 / 65.52 2 4
3 13 1313.00 18 15.02 2108 570 2.45 / 66.09 2 7
4 13 809.56 18 15.13 1451 395 2.84 / 66.49 2 8
5 13 197.72 18 15.30 618 170 3.01 / 66.66 2 8
6 13 17.64 18 15.33 349 96 3.11 / 66.75 2 5
7 8 0.24 165 15.28 315 794 3.90 / 67.55 2 11
Average= 3.75 (KJ/cycle)

Cycle 16 GMT 25/ 4/2023 0:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 28 15.24 475 203 0.20 / 60.00 2 2
2 7 2003.24 38 14.89 2962 1676 1.88 / 61.68 2 4
3 13 1239.20 18 15.04 2015 546 2.42 / 62.23 2 7
4 13 695.24 18 15.17 1301 355 2.78 / 62.58 2 8
5 13 190.88 18 15.31 605 167 2.95 / 62.75 2 8
6 13 17.12 18 15.34 356 98 3.04 / 62.85 2 9
7 8 0.04 165 15.29 317 800 3.84 / 63.65 2 16
Average= 3.74 (KJ/cycle)

Cycle 15 GMT 15/ 4/2023 4:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 28 15.21 479 204 0.20 / 56.16 2 2
2 7 2007.24 38 14.88 2960 1674 1.88 / 57.83 2 4
3 13 1265.32 18 15.04 2039 552 2.43 / 58.38 2 7
4 13 682.96 18 15.17 1280 350 2.78 / 58.73 2 8
5 13 177.68 18 15.31 586 161 2.94 / 58.89 2 8
6 13 28.68 18 15.33 373 103 3.04 / 59.00 2 7
7 8 0.16 165 15.29 319 805 3.85 / 59.80 2 13
Average= 3.74 (KJ/cycle)

Cycle 14 GMT 5/ 4/2023 9:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 28 15.24 472 201 0.20 / 52.29 2 2
2 7 2002.48 38 14.88 2965 1677 1.88 / 53.96 2 4
3 13 1293.24 18 15.03 2078 562 2.44 / 54.53 2 7
4 13 670.44 18 15.18 1269 347 2.79 / 54.87 2 8
5 13 224.84 18 15.29 655 180 2.97 / 55.05 2 8
6 13 25.60 18 15.35 364 101 3.07 / 55.15 2 6
7 8 0.16 165 15.29 317 800 3.87 / 55.95 2 13
Average= 3.73 (KJ/cycle)

Cycle 13 GMT 26/ 3/2023 14: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 28 15.24 469 200 0.20 / 48.48 2 2
2 7 2002.16 38 14.89 2958 1674 1.87 / 50.15 2 4
3 13 1204.00 18 15.06 1964 532 2.41 / 50.68 2 7
4 13 679.96 18 15.17 1282 350 2.76 / 51.03 2 8
5 13 140.12 18 15.32 535 148 2.90 / 51.18 2 7
6 13 17.96 18 15.34 352 97 3.00 / 51.28 2 4
7 8 0.08 165 15.30 320 808 3.81 / 52.09 2 8
Average= 3.72 (KJ/cycle)

Cycle 12 GMT 16/ 3/2023 18:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 28 15.26 466 199 0.20 / 44.60 2 2
2 7 2003.52 39 14.90 2962 1721 1.92 / 46.32 2 5
3 13 1280.72 18 15.05 2060 558 2.48 / 46.88 2 7
4 13 692.52 18 15.18 1293 353 2.83 / 47.23 2 8
5 13 148.96 18 15.33 541 149 2.98 / 47.38 2 8
6 13 20.68 18 15.34 353 97 3.08 / 47.48 2 9
7 8 0.08 165 15.30 316 798 3.88 / 48.28 2 18
Average= 3.71 (KJ/cycle)

Cycle 11 GMT 6/ 3/2023 23:10: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 28 15.25 473 202 0.20 / 40.82 2 2
2 7 2003.40 38 14.89 2952 1670 1.87 / 42.49 2 4
3 13 1354.40 18 15.04 2156 584 2.46 / 43.08 2 7
4 13 743.76 18 15.18 1373 375 2.83 / 43.45 2 8
5 13 172.84 18 15.33 578 159 2.99 / 43.61 2 8
6 8 0.00 165 15.32 312 789 3.78 / 44.40 2 11
Average= 3.70 (KJ/cycle)

Cycle 10 GMT 25/ 2/2023 3:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 28 15.27 467 200 0.20 / 37.04 2 2
2 7 2004.64 38 14.88 2960 1674 1.87 / 38.72 2 4
3 13 1291.72 18 15.04 2080 563 2.44 / 39.28 2 7
4 13 782.40 18 15.16 1407 384 2.82 / 39.66 2 8
5 13 195.92 18 15.31 607 167 2.99 / 39.83 2 8
6 8 0.20 165 15.31 313 791 3.78 / 40.62 2 12
Average= 3.69 (KJ/cycle)

Cycle 9 GMT 15/ 2/2023 8:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 28 15.29 463 198 0.20 / 33.29 2 2
2 7 2005.72 38 14.91 2961 1678 1.88 / 34.96 2 4
3 13 1227.72 18 15.06 1991 540 2.42 / 35.50 2 7
4 13 733.16 18 15.18 1343 367 2.78 / 35.87 2 8
5 13 219.08 18 15.31 642 177 2.96 / 36.05 2 8
6 8 0.16 165 15.31 315 796 3.76 / 36.84 2 12
Average= 3.68 (KJ/cycle)

Cycle 8 GMT 5/ 2/2023 13:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 28 15.26 468 200 0.20 / 29.58 2 2
2 7 2003.84 38 14.91 2960 1677 1.88 / 31.26 2 4
3 13 1247.28 18 15.06 2016 546 2.42 / 31.80 2 7
4 13 662.32 18 15.20 1250 342 2.77 / 32.14 2 8
5 13 167.64 18 15.33 567 156 2.92 / 32.30 2 7
6 8 0.12 165 15.34 311 787 3.71 / 33.09 2 11
Average= 3.68 (KJ/cycle)

Cycle 7 GMT 26/ 1/2023 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 28 15.27 461 197 0.20 / 25.03 2 2
2 7 2004.40 74 14.80 2952 3233 3.43 / 28.26 2 5
3 13 331.72 18 15.29 796 219 3.65 / 28.48 2 8
4 13 37.12 18 15.35 378 104 3.75 / 28.58 2 6
5 8 0.08 165 15.32 315 796 4.55 / 29.38 2 14
Average= 3.67 (KJ/cycle)

Cycle 6 GMT 16/ 1/2023 20:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 27 15.27 458 189 0.19 / 20.46 2 2
2 3 1048.68 1 15.28 1803 28 0.22 / 20.49 2 5
3 7 2006.24 74 14.82 2946 3231 3.45 / 23.72 2 5
4 13 352.36 18 15.30 822 226 3.67 / 23.95 2 9
5 13 22.32 18 15.36 348 96 3.77 / 24.04 2 7
6 8 0.08 165 15.33 310 784 4.55 / 24.83 2 19
Average= 3.55 (KJ/cycle)

Cycle 5 GMT 6/ 1/2023 23: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 29 15.27 462 205 0.20 / 15.94 2 3
2 3 935.12 -1 15.63 0 0 0.00 / 15.94 2 3
3 3 959.20 -1 15.69 0 0 0.00 / 15.94 2 3
4 7 2004.96 74 14.81 2936 3218 3.42 / 19.16 2 6
5 13 351.88 18 15.30 815 224 3.65 / 19.38 2 9
6 13 38.84 18 15.37 373 103 3.75 / 19.48 2 7
7 8 0.12 165 15.33 313 792 4.54 / 20.27 2 19
Average= 3.38 (KJ/cycle)

Cycle 4 GMT 28/12/2022 1:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 28 15.27 473 202 0.20 / 12.19 2 3
2 7 1522.08 75 14.99 2334 2624 2.83 / 14.81 2 6
3 13 134.00 18 15.35 513 142 2.97 / 14.96 2 8
4 8 0.12 165 15.34 307 777 3.75 / 15.73 2 11
Average= 3.15 (KJ/cycle)

Cycle 3 GMT 27/12/2022 2: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 28 15.29 458 196 0.20 / 8.51 2 3
2 3 943.00 -1 15.66 0 0 0.00 / 8.51 2 3
3 3 971.32 -1 15.67 0 0 0.00 / 8.51 2 3
4 7 1512.52 74 14.98 2306 2556 2.75 / 11.06 2 7
5 13 148.40 18 15.36 526 145 2.90 / 11.21 2 8
6 8 0.16 165 15.33 308 779 3.68 / 11.99 2 18
Average= 3.00 (KJ/cycle)

Cycle 2 GMT 26/12/2022 2:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 31 15.31 471 224 0.22 / 4.78 2 2
2 3 820.48 -3 15.68 0 0 0.00 / 4.78 2 2
3 3 1035.24 1 15.35 1773 27 0.25 / 4.81 2 4
4 7 1527.92 74 14.97 2334 2586 2.84 / 7.39 2 7
5 13 147.24 18 15.34 524 145 2.98 / 7.54 2 8
6 8 0.16 165 15.33 305 771 3.75 / 8.31 2 17
Average= 2.77 (KJ/cycle)

Cycle 1 GMT 25/12/2022 3: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 26 15.48 431 173 0.17 / 1.92 2 2
2 7 1001.40 74 15.17 1641 1842 2.02 / 3.77 2 8
3 8 -0.04 165 15.39 312 792 2.81 / 4.56 2 17
Average= 2.28 (KJ/cycle)

Cycle 0 GMT 24/12/2022 16:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.52 26 15.62 486 197 0.20 / 0.20 2 2
2 7 168.16 74 15.61 497 574 0.77 / 0.77 2 3
3 8 0.20 240 15.57 262 979 1.75 / 1.75 2 6
Average= 1.75 (KJ/cycle)