SIO Argo Site:
Pump Diagnostics Page   



Serial= 3148 WMO= 3902289

Return

←PreviousNext→

Cycle 76 GMT 2/12/2024 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 38 15.03 406 232 0.23 / 308.84 2 4
2 3 978.80 -1 15.41 0 0 0.00 / 308.84 2 4
3 3 1029.52 1 15.11 1780 27 0.26 / 308.86 2 10
4 7 2022.84 38 14.72 2974 1664 1.92 / 310.53 2 10
5 13 1664.24 16 14.75 2547 601 2.52 / 311.13 2 12
6 13 1155.16 16 14.81 1891 448 2.97 / 311.58 2 13
7 13 593.44 16 14.95 1133 271 3.24 / 311.85 2 13
8 13 209.24 16 15.05 590 142 3.38 / 311.99 2 13
9 8 0.20 165 15.08 269 669 4.05 / 312.66 2 14
Average= 4.06
(KJ/cycle)

Cycle 75 GMT 22/11/2024 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 38 15.04 406 232 0.23 / 304.75 2 4
2 7 2006.52 38 14.73 2955 1654 1.89 / 306.41 2 8
3 13 1745.88 16 14.76 2636 623 2.51 / 307.03 2 11
4 13 1203.52 16 14.83 1949 462 2.97 / 307.49 2 13
5 13 635.72 16 14.95 1193 285 3.26 / 307.78 2 14
6 13 245.76 16 15.05 641 154 3.41 / 307.93 2 13
7 8 0.20 165 15.09 271 675 4.09 / 308.61 2 13
Average= 4.06
(KJ/cycle)

Cycle 74 GMT 12/11/2024 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 38 15.05 414 237 0.24 / 300.66 2 3
2 7 2008.00 38 14.74 2963 1660 1.90 / 302.32 2 9
3 13 1702.68 16 14.77 2593 613 2.51 / 302.93 2 11
4 13 1258.04 16 14.82 2031 482 2.99 / 303.41 2 12
5 13 663.20 16 14.95 1232 295 3.29 / 303.71 2 13
6 13 220.80 16 15.07 605 146 3.43 / 303.85 2 13
7 8 0.32 165 15.09 268 667 4.10 / 304.52 2 18
Average= 4.06
(KJ/cycle)

Cycle 73 GMT 3/11/2024 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 39 15.04 410 240 0.24 / 296.61 2 4
2 7 2022.80 38 14.75 2973 1666 1.91 / 298.27 2 9
3 13 1606.24 16 14.78 2475 585 2.49 / 298.86 2 10
4 13 1223.96 16 14.83 1979 470 2.96 / 299.33 2 12
5 13 645.16 16 14.96 1203 288 3.25 / 299.62 2 13
6 13 205.56 16 15.09 582 141 3.39 / 299.76 2 13
7 8 0.08 165 15.10 267 665 4.06 / 300.42 2 22
Average= 4.06
(KJ/cycle)

Cycle 72 GMT 24/10/2024 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.60 38 15.05 434 248 0.25 / 292.55 2 4
2 7 2014.00 38 14.73 2957 1655 1.90 / 294.20 2 11
3 13 1652.44 16 14.77 2521 596 2.50 / 294.80 2 11
4 13 1209.52 16 14.83 1958 465 2.96 / 295.26 2 12
5 13 714.96 16 14.94 1295 310 3.27 / 295.57 2 13
6 13 189.16 16 15.09 553 134 3.41 / 295.70 2 14
7 8 0.08 165 15.10 266 663 4.07 / 296.37 2 17
Average= 4.06
(KJ/cycle)

Cycle 71 GMT 14/10/2024 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 38 15.05 434 248 0.25 / 288.42 2 4
2 7 2006.84 39 14.73 2960 1700 1.95 / 290.12 2 12
3 13 1744.04 16 14.76 2655 627 2.58 / 290.75 2 11
4 13 1130.24 16 14.85 1858 441 3.02 / 291.19 2 13
5 13 653.52 16 14.96 1213 290 3.31 / 291.48 2 14
6 13 211.16 16 15.09 587 142 3.45 / 291.62 2 13
7 8 0.00 165 15.09 270 672 4.12 / 292.30 2 16
Average= 4.06
(KJ/cycle)

Cycle 70 GMT 4/10/2024 18:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 38 15.06 423 242 0.24 / 284.33 2 4
2 7 2005.40 39 14.75 2957 1701 1.94 / 286.03 2 8
3 13 1655.00 16 14.79 2539 601 2.54 / 286.63 2 10
4 13 1090.80 16 14.88 1785 425 2.97 / 287.06 2 12
5 13 700.08 16 14.96 1278 306 3.27 / 287.37 2 13
6 13 206.48 16 15.10 577 139 3.41 / 287.50 2 13
7 8 0.28 165 15.11 269 671 4.08 / 288.18 2 17
Average= 4.06
(KJ/cycle)

Cycle 69 GMT 24/ 9/2024 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.64 38 15.06 428 245 0.24 / 280.29 2 3
2 7 2021.84 38 14.76 2970 1666 1.91 / 281.96 2 8
3 13 1619.96 16 14.79 2487 589 2.50 / 282.54 2 10
4 13 1189.56 16 14.86 1932 459 2.96 / 283.00 2 11
5 13 617.84 16 14.99 1162 279 3.24 / 283.28 2 12
6 13 194.32 16 15.11 562 136 3.37 / 283.42 2 12
7 8 -0.08 165 15.11 270 673 4.05 / 284.09 2 22
Average= 4.06
(KJ/cycle)

Cycle 68 GMT 15/ 9/2024 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 38 15.07 415 238 0.24 / 276.21 2 4
2 7 2009.24 38 14.76 2954 1657 1.89 / 277.86 2 9
3 13 1669.68 16 14.79 2541 601 2.50 / 278.46 2 10
4 13 1195.56 16 14.84 1943 461 2.96 / 278.92 2 12
5 13 674.16 16 14.97 1244 298 3.26 / 279.22 2 13
6 13 230.68 16 15.10 615 149 3.40 / 279.37 2 13
7 8 0.00 165 15.11 270 673 4.08 / 280.04 2 22
Average= 4.06
(KJ/cycle)

Cycle 67 GMT 5/ 9/2024 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 38 15.07 431 247 0.25 / 272.14 2 4
2 7 2015.60 38 14.77 2967 1665 1.91 / 273.80 2 8
3 13 1682.16 16 14.81 2569 609 2.52 / 274.41 2 10
4 13 1204.24 16 14.87 1951 464 2.99 / 274.87 2 11
5 13 580.76 16 15.01 1114 268 3.25 / 275.14 2 14
6 13 239.76 16 15.12 628 152 3.40 / 275.29 2 13
7 8 0.08 165 15.13 270 674 4.08 / 275.97 2 13
Average= 4.06
(KJ/cycle)

Cycle 66 GMT 26/ 8/2024 15:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 38 15.09 428 245 0.25 / 268.07 2 3
2 7 2019.12 38 14.74 2983 1671 1.92 / 269.74 2 8
3 13 1592.28 16 14.79 2464 583 2.50 / 270.33 2 13
4 13 1220.08 16 14.83 1983 471 2.97 / 270.80 2 12
5 13 588.64 16 14.99 1125 270 3.24 / 271.07 2 13
6 13 237.80 16 15.09 625 151 3.39 / 271.22 2 13
7 8 0.16 165 15.10 270 673 4.06 / 271.89 2 19
Average= 4.06
(KJ/cycle)

Cycle 65 GMT 16/ 8/2024 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 38 15.07 428 245 0.25 / 264.00 2 3
2 7 2020.44 38 14.78 2979 1673 1.92 / 265.67 2 9
3 13 1631.36 16 14.82 2518 597 2.52 / 266.27 2 10
4 13 1199.76 16 14.87 1951 464 2.98 / 266.73 2 14
5 13 593.96 16 15.02 1136 273 3.25 / 267.01 2 14
6 13 209.32 16 15.13 587 142 3.39 / 267.15 2 13
7 8 0.16 165 15.14 271 677 4.07 / 267.83 2 20
Average= 4.06
(KJ/cycle)

Cycle 64 GMT 7/ 8/2024 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 38 15.08 408 234 0.23 / 259.87 2 4
2 7 2008.16 38 14.76 2953 1656 1.89 / 261.53 2 8
3 13 1710.20 16 14.79 2603 616 2.51 / 262.14 2 11
4 13 1250.08 16 14.85 2006 477 2.98 / 262.62 2 14
5 13 754.92 16 14.97 1351 324 3.31 / 262.94 2 12
6 13 210.76 16 15.12 585 142 3.45 / 263.08 2 12
7 8 -0.08 165 15.12 269 671 4.12 / 263.75 2 20
Average= 4.06
(KJ/cycle)

Cycle 63 GMT 28/ 7/2024 7:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 38 15.07 434 249 0.25 / 255.83 2 4
2 7 2013.60 38 14.77 2968 1666 1.91 / 257.50 2 9
3 13 1698.28 16 14.81 2591 614 2.53 / 258.11 2 11
4 13 1055.64 16 14.91 1761 420 2.95 / 258.53 2 14
5 13 647.36 16 15.03 1210 291 3.24 / 258.82 2 13
6 13 207.68 16 15.15 584 142 3.38 / 258.97 2 14
7 8 -0.24 165 15.14 268 669 4.05 / 259.64 2 20
Average= 4.06
(KJ/cycle)

Cycle 62 GMT 18/ 7/2024 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 38 15.10 399 229 0.23 / 251.74 2 3
2 7 2007.00 38 14.75 2957 1657 1.89 / 253.39 2 7
3 13 1645.36 16 14.80 2517 596 2.48 / 253.99 2 15
4 13 1176.16 16 14.87 1914 455 2.94 / 254.44 2 12
5 13 739.16 16 14.97 1329 318 3.26 / 254.76 2 13
6 13 232.96 16 15.11 614 148 3.40 / 254.91 2 13
7 8 0.16 165 15.13 270 674 4.08 / 255.58 2 20
Average= 4.06
(KJ/cycle)

Cycle 61 GMT 8/ 7/2024 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.68 38 15.09 426 244 0.24 / 247.68 2 4
2 7 2006.44 38 14.76 2955 1657 1.90 / 249.34 2 11
3 13 1608.84 16 14.83 2471 586 2.49 / 249.92 2 11
4 13 1274.60 16 14.86 2046 486 2.97 / 250.41 2 13
5 13 625.88 16 15.03 1172 282 3.26 / 250.69 2 14
6 13 233.52 16 15.13 611 148 3.40 / 250.84 2 12
7 8 0.20 165 15.15 267 667 4.07 / 251.51 2 19
Average= 4.06
(KJ/cycle)

Cycle 60 GMT 28/ 6/2024 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 38 15.09 395 227 0.23 / 243.57 2 3
2 7 2009.04 39 14.76 2960 1704 1.93 / 245.27 2 13
3 13 1694.12 16 14.81 2575 610 2.54 / 245.88 2 10
4 13 1132.52 16 14.89 1854 442 2.98 / 246.33 2 14
5 13 658.28 16 15.02 1214 292 3.27 / 246.62 2 13
6 13 222.44 16 15.14 602 146 3.42 / 246.76 2 12
7 8 0.24 165 15.16 268 670 4.09 / 247.43 2 16
Average= 4.06
(KJ/cycle)

Cycle 59 GMT 19/ 6/2024 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 38 15.10 400 230 0.23 / 239.51 2 3
2 7 2010.52 38 14.77 2954 1658 1.89 / 241.17 2 10
3 13 1624.48 16 14.83 2494 592 2.48 / 241.76 2 11
4 13 1235.36 16 14.88 1993 474 2.95 / 242.23 2 12
5 13 644.00 16 15.04 1203 289 3.24 / 242.52 2 13
6 13 236.40 16 15.13 623 151 3.39 / 242.67 2 13
7 8 0.08 165 15.15 269 672 4.07 / 243.34 2 24
Average= 4.06
(KJ/cycle)

Cycle 58 GMT 9/ 6/2024 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 38 15.11 403 231 0.23 / 235.41 2 3
2 7 2005.84 38 14.77 2957 1660 1.89 / 237.07 2 9
3 13 1729.80 16 14.81 2643 626 2.52 / 237.70 2 10
4 13 1206.92 16 14.89 1960 467 2.98 / 238.16 2 13
5 13 673.40 16 15.01 1242 298 3.28 / 238.46 2 13
6 13 212.80 16 15.15 590 143 3.43 / 238.61 2 14
7 8 0.24 165 15.16 269 673 4.10 / 239.28 2 19
Average= 4.06
(KJ/cycle)

Cycle 57 GMT 30/ 5/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 38 15.12 407 234 0.23 / 231.35 2 3
2 7 2008.60 38 14.77 2975 1670 1.90 / 233.02 2 10
3 13 1691.84 16 14.83 2597 616 2.52 / 233.63 2 11
4 13 1148.92 16 14.91 1887 450 2.97 / 234.08 2 14
5 13 654.60 16 15.03 1218 293 3.26 / 234.37 2 14
6 13 195.36 16 15.16 565 137 3.40 / 234.51 2 13
7 8 0.52 165 15.16 267 668 4.07 / 235.18 2 14
Average= 4.05
(KJ/cycle)

Cycle 56 GMT 20/ 5/2024 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 38 15.11 396 227 0.23 / 227.26 2 3
2 7 2010.48 38 14.77 2970 1667 1.89 / 228.93 2 9
3 13 1691.72 16 14.83 2593 615 2.51 / 229.54 2 10
4 13 1227.60 16 14.89 1993 475 2.98 / 230.02 2 12
5 13 642.00 16 15.04 1202 289 3.27 / 230.31 2 13
6 13 194.24 16 15.16 563 137 3.41 / 230.44 2 13
7 8 0.52 165 15.16 267 668 4.08 / 231.11 2 20
Average= 4.05
(KJ/cycle)

Cycle 55 GMT 11/ 5/2024 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 38 15.11 426 245 0.24 / 223.18 2 4
2 7 2025.68 39 14.78 3002 1730 1.98 / 224.92 2 14
3 13 1660.56 16 14.82 2557 606 2.58 / 225.52 2 11
4 13 1077.16 16 14.93 1797 429 3.01 / 225.95 2 15
5 13 616.76 16 15.07 1167 281 3.29 / 226.23 2 14
6 13 177.04 16 15.18 538 131 3.42 / 226.36 2 12
7 8 -0.04 165 15.17 268 671 4.09 / 227.03 2 17
Average= 4.05
(KJ/cycle)

Cycle 54 GMT 1/ 5/2024 7:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 38 15.12 401 230 0.23 / 219.07 2 3
2 7 2014.00 38 14.78 2975 1671 1.90 / 220.74 2 12
3 13 1746.28 16 14.81 2659 630 2.53 / 221.37 2 10
4 13 1192.44 16 14.91 1946 464 3.00 / 221.83 2 14
5 13 661.08 16 15.05 1232 297 3.29 / 222.13 2 14
6 13 201.40 16 15.17 572 139 3.43 / 222.27 2 13
7 8 0.24 165 15.17 269 673 4.10 / 222.94 2 21
Average= 4.05
(KJ/cycle)

Cycle 53 GMT 21/ 4/2024 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 38 15.12 396 228 0.23 / 214.95 2 3
2 7 2009.68 39 14.80 2957 1707 1.93 / 216.65 2 9
3 13 1682.20 16 14.83 2566 609 2.54 / 217.26 2 13
4 13 1164.40 16 14.92 1896 453 3.00 / 217.71 2 14
5 13 680.00 16 15.03 1245 299 3.30 / 218.01 2 12
6 13 220.12 16 15.16 606 147 3.44 / 218.16 2 13
7 8 0.40 165 15.16 270 675 4.12 / 218.84 2 21
Average= 4.05
(KJ/cycle)

Cycle 52 GMT 11/ 4/2024 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.08 38 15.14 434 250 0.25 / 210.88 2 3
2 7 2008.64 38 14.79 2957 1662 1.91 / 212.54 2 8
3 13 1653.36 16 14.85 2530 601 2.51 / 213.14 2 11
4 13 1222.28 16 14.90 1971 470 2.98 / 213.61 2 15
5 13 630.28 16 15.06 1188 286 3.27 / 213.89 2 14
6 13 231.72 16 15.18 618 150 3.42 / 214.04 2 13
7 8 -0.04 165 15.18 269 674 4.09 / 214.72 2 20
Average= 4.05
(KJ/cycle)

Cycle 51 GMT 1/ 4/2024 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 38 15.13 408 235 0.23 / 206.84 2 4
2 7 2010.12 38 14.79 2965 1666 1.90 / 208.51 2 10
3 13 1599.28 16 14.87 2467 587 2.49 / 209.10 2 11
4 13 1141.80 16 14.94 1867 446 2.93 / 209.54 2 15
5 13 615.04 16 15.07 1162 280 3.21 / 209.82 2 13
6 13 186.04 16 15.18 550 134 3.35 / 209.96 2 12
7 8 -0.04 165 15.19 267 669 4.02 / 210.63 2 16
Average= 4.05
(KJ/cycle)

Cycle 50 GMT 23/ 3/2024 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 38 15.14 408 235 0.23 / 202.80 2 3
2 7 2015.68 38 14.79 2970 1669 1.90 / 204.46 2 12
3 13 1635.60 16 14.85 2514 597 2.50 / 205.06 2 12
4 13 1087.44 16 14.95 1800 431 2.93 / 205.49 2 14
5 13 702.28 16 15.05 1282 309 3.24 / 205.80 2 12
6 13 198.56 16 15.18 568 138 3.38 / 205.94 2 12
7 8 0.16 165 15.18 267 669 4.05 / 206.61 2 14
Average= 4.05
(KJ/cycle)

Cycle 49 GMT 13/ 3/2024 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 38 15.14 404 232 0.23 / 198.66 2 3
2 7 2023.64 38 14.80 2997 1686 1.92 / 200.35 2 16
3 13 1716.40 16 14.84 2629 624 2.54 / 200.97 2 12
4 13 1273.76 16 14.91 2060 491 3.03 / 201.46 2 12
5 13 645.56 16 15.07 1205 291 3.32 / 201.75 2 13
6 13 200.56 16 15.19 573 139 3.46 / 201.89 2 14
7 8 -0.36 165 15.19 267 669 4.13 / 202.56 2 19
Average= 4.05
(KJ/cycle)

Cycle 48 GMT 3/ 3/2024 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 38 15.14 409 235 0.24 / 194.59 2 4
2 7 2022.64 38 14.80 2979 1675 1.91 / 196.26 2 8
3 13 1705.64 16 14.84 2597 617 2.53 / 196.88 2 11
4 13 1186.52 16 14.92 1929 460 2.99 / 197.34 2 14
5 13 622.32 16 15.07 1169 282 3.27 / 197.62 2 13
6 13 192.32 16 15.19 559 136 3.41 / 197.76 2 13
7 8 0.04 165 15.19 268 672 4.08 / 198.43 2 23
Average= 4.05
(KJ/cycle)

Cycle 47 GMT 22/ 2/2024 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 38 15.15 426 245 0.25 / 190.46 2 4
2 3 1018.12 1 15.21 1783 27 0.27 / 190.49 2 9
3 7 2023.08 38 14.81 2983 1679 1.95 / 192.17 2 10
4 13 1662.72 16 14.88 2551 607 2.56 / 192.77 2 11
5 13 1147.12 16 14.96 1867 447 3.01 / 193.22 2 13
6 13 737.84 16 15.05 1332 321 3.33 / 193.54 2 14
7 13 185.80 16 15.19 549 133 3.46 / 193.67 2 12
8 8 -0.20 165 15.21 270 678 4.14 / 194.35 2 20
Average= 4.05
(KJ/cycle)

Cycle 46 GMT 13/ 2/2024 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 38 15.15 413 238 0.24 / 186.36 2 4
2 7 2011.40 38 14.83 2972 1675 1.91 / 188.03 2 14
3 13 1695.96 16 14.87 2601 619 2.53 / 188.65 2 10
4 13 1193.68 16 14.94 1953 467 3.00 / 189.12 2 13
5 13 596.20 16 15.10 1135 274 3.27 / 189.39 2 14
6 13 194.12 16 15.21 562 137 3.41 / 189.53 2 11
7 8 -0.12 165 15.21 272 683 4.09 / 190.21 2 19
Average= 4.05
(KJ/cycle)

Cycle 45 GMT 3/ 2/2024 7:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 38 15.17 407 235 0.23 / 182.28 2 4
2 7 2005.92 38 14.80 2976 1674 1.91 / 183.95 2 8
3 13 1682.52 16 14.86 2583 614 2.52 / 184.56 2 14
4 13 1148.40 16 14.96 1896 454 2.98 / 185.02 2 12
5 13 654.44 16 15.07 1223 295 3.27 / 185.31 2 13
6 13 159.52 16 15.20 512 125 3.40 / 185.44 2 12
7 8 0.08 165 15.20 273 685 4.08 / 186.12 2 15
Average= 4.05
(KJ/cycle)

Cycle 44 GMT 24/ 1/2024 13:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 38 15.15 411 237 0.24 / 178.20 2 4
2 7 2006.08 38 14.83 2959 1668 1.90 / 179.87 2 7
3 13 1697.16 16 14.88 2598 619 2.52 / 180.48 2 12
4 13 1088.00 16 15.00 1810 434 2.96 / 180.92 2 13
5 13 658.36 16 15.10 1226 296 3.25 / 181.22 2 14
6 13 201.76 16 15.22 577 141 3.39 / 181.36 2 12
7 8 0.56 165 15.23 273 686 4.08 / 182.04 2 21
Average= 4.05
(KJ/cycle)

Cycle 43 GMT 14/ 1/2024 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 38 15.17 407 235 0.23 / 174.15 2 3
2 7 2006.56 38 14.83 2954 1665 1.90 / 175.81 2 10
3 13 1587.76 16 14.90 2451 584 2.48 / 176.40 2 11
4 13 1165.36 16 14.97 1913 458 2.94 / 176.86 2 13
5 13 639.04 16 15.09 1200 290 3.23 / 177.15 2 13
6 13 180.36 16 15.22 546 133 3.36 / 177.28 2 14
7 8 0.16 165 15.21 272 683 4.05 / 177.96 2 19
Average= 4.04
(KJ/cycle)

Cycle 42 GMT 5/ 1/2024 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 38 15.16 411 237 0.24 / 169.94 2 5
2 7 2018.76 38 14.83 2996 1688 1.93 / 171.63 2 13
3 13 1649.40 18 14.89 2544 682 2.61 / 172.31 2 14
4 13 1068.72 18 14.99 1789 483 3.09 / 172.80 2 14
5 13 599.72 18 15.11 1147 312 3.40 / 173.11 2 13
6 13 106.60 18 15.23 437 120 3.52 / 173.23 2 10
7 8 0.04 165 15.23 273 686 4.21 / 173.91 2 19
Average= 4.04
(KJ/cycle)

Cycle 41 GMT 26/12/2023 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 38 15.15 414 238 0.24 / 165.84 2 3
2 7 2008.08 38 14.82 2981 1679 1.92 / 167.52 2 10
3 13 1660.04 18 14.86 2549 682 2.60 / 168.20 2 11
4 13 1071.76 18 14.97 1781 480 3.08 / 168.68 2 12
5 13 445.52 18 15.14 924 252 3.33 / 168.93 2 13
6 13 52.04 18 15.25 349 96 3.43 / 169.03 2 13
7 8 0.56 165 15.20 271 680 4.11 / 169.71 2 21
Average= 4.04
(KJ/cycle)

Cycle 40 GMT 16/12/2023 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 38 15.16 433 249 0.25 / 161.74 2 3
2 7 2007.56 38 14.83 2975 1677 1.93 / 163.42 2 9
3 13 1573.68 18 14.89 2443 655 2.58 / 164.07 2 15
4 13 1047.36 18 14.97 1745 470 3.05 / 164.54 2 13
5 13 500.88 18 15.12 1000 272 3.32 / 164.81 2 14
6 13 85.04 18 15.22 399 109 3.43 / 164.92 2 10
7 8 0.04 165 15.20 271 680 4.11 / 165.60 2 24
Average= 4.04
(KJ/cycle)

Cycle 39 GMT 6/12/2023 16:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 38 15.15 407 234 0.23 / 157.68 2 4
2 7 2006.20 38 14.85 2977 1680 1.91 / 159.36 2 10
3 13 1585.96 18 14.89 2467 661 2.58 / 160.02 2 12
4 13 1032.48 18 15.00 1733 468 3.04 / 160.49 2 13
5 13 420.68 18 15.15 883 241 3.28 / 160.73 2 13
6 13 39.28 18 15.25 328 90 3.37 / 160.82 2 13
7 8 0.24 165 15.21 268 673 4.05 / 161.49 2 14
Average= 4.04
(KJ/cycle)

Cycle 38 GMT 26/11/2023 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 38 15.16 428 247 0.25 / 153.51 2 4
2 7 2022.56 38 14.81 2990 1683 1.93 / 155.19 2 10
3 13 1695.76 18 14.85 2599 695 2.62 / 155.89 2 10
4 13 1104.48 18 14.97 1823 491 3.12 / 156.38 2 13
5 13 511.12 18 15.12 1014 276 3.39 / 156.66 2 12
6 13 98.88 18 15.22 417 114 3.51 / 156.77 2 13
7 8 -0.20 165 15.21 268 673 4.18 / 157.44 2 11
Average= 4.04
(KJ/cycle)

Cycle 37 GMT 17/11/2023 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 38 15.18 423 244 0.24 / 149.30 2 3
2 7 2009.12 39 14.82 2977 1721 1.96 / 151.02 2 10
3 13 1704.28 18 14.87 2603 697 2.66 / 151.71 2 10
4 13 1174.04 18 14.97 1919 517 3.18 / 152.23 2 12
5 13 460.40 18 15.15 943 257 3.44 / 152.49 2 13
6 13 62.48 18 15.24 363 100 3.54 / 152.59 2 10
7 8 0.00 165 15.22 269 676 4.21 / 153.26 2 19
Average= 4.03
(KJ/cycle)

Cycle 36 GMT 7/11/2023 8:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 38 15.17 414 239 0.24 / 145.21 2 4
2 7 2005.88 38 14.82 2964 1669 1.91 / 146.87 2 9
3 13 1684.24 18 14.86 2575 689 2.60 / 147.56 2 11
4 13 1084.36 18 14.98 1803 486 3.08 / 148.05 2 13
5 13 427.64 18 15.16 887 242 3.32 / 148.29 2 13
6 13 43.60 18 15.26 332 91 3.42 / 148.38 2 8
7 8 0.32 165 15.23 267 671 4.09 / 149.05 2 13
Average= 4.03
(KJ/cycle)

Cycle 35 GMT 28/10/2023 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 37 15.17 425 239 0.24 / 141.01 2 3
2 7 2022.56 38 14.84 2975 1678 1.92 / 142.68 2 10
3 13 1690.40 18 14.88 2584 692 2.61 / 143.38 2 10
4 13 1094.84 18 14.99 1815 490 3.10 / 143.87 2 12
5 13 580.72 18 15.11 1112 302 3.40 / 144.17 2 13
6 13 106.08 18 15.24 429 118 3.52 / 144.29 2 10
7 8 -0.28 165 15.23 271 681 4.20 / 144.97 2 19
Average= 4.03
(KJ/cycle)

Cycle 34 GMT 18/10/2023 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 37 15.18 403 226 0.23 / 136.93 2 4
2 7 2008.16 38 14.84 2973 1677 1.90 / 138.60 2 9
3 13 1599.24 18 14.90 2469 662 2.57 / 139.27 2 11
4 13 988.88 18 15.02 1679 454 3.02 / 139.72 2 11
5 13 453.92 18 15.15 934 255 3.27 / 139.97 2 12
6 13 90.32 18 15.26 408 112 3.39 / 140.09 2 9
7 8 -0.36 165 15.22 271 681 4.07 / 140.77 2 20
Average= 4.02
(KJ/cycle)

Cycle 33 GMT 9/10/2023 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 37 15.18 419 235 0.24 / 132.79 2 3
2 7 2008.40 39 14.85 2967 1718 1.95 / 134.51 2 10
3 13 1565.20 18 14.91 2423 650 2.60 / 135.16 2 11
4 13 1087.80 18 15.00 1798 485 3.09 / 135.64 2 14
5 13 486.84 18 15.15 982 268 3.36 / 135.91 2 12
6 13 78.04 18 15.25 388 107 3.46 / 136.02 2 11
7 8 -0.12 165 15.23 272 684 4.15 / 136.70 2 18
Average= 4.02
(KJ/cycle)

Cycle 32 GMT 29/ 9/2023 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 37 15.19 411 231 0.23 / 128.62 2 3
2 7 2017.96 38 14.85 2991 1688 1.92 / 130.31 2 9
3 13 1696.20 18 14.90 2597 697 2.62 / 131.00 2 13
4 13 1132.56 18 14.99 1866 503 3.12 / 131.51 2 15
5 13 476.48 18 15.16 972 265 3.38 / 131.77 2 13
6 13 72.96 18 15.26 379 104 3.49 / 131.88 2 11
7 8 0.44 165 15.24 269 676 4.16 / 132.55 2 20
Average= 4.02
(KJ/cycle)

Cycle 31 GMT 19/ 9/2023 11:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 37 15.20 407 229 0.23 / 124.50 2 3
2 7 2007.04 38 14.86 2964 1674 1.90 / 126.18 2 10
3 13 1605.84 18 14.92 2481 666 2.57 / 126.84 2 11
4 13 1091.44 18 15.02 1807 489 3.06 / 127.33 2 12
5 13 508.08 18 15.16 1011 276 3.33 / 127.61 2 13
6 13 60.00 18 15.27 362 99 3.43 / 127.71 2 12
7 8 -0.20 165 15.24 272 684 4.12 / 128.39 2 19
Average= 4.01
(KJ/cycle)

Cycle 30 GMT 9/ 9/2023 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 37 15.19 434 244 0.24 / 120.40 2 4
2 7 2006.92 38 14.86 2978 1682 1.93 / 122.08 2 9
3 13 1615.56 18 14.91 2501 671 2.60 / 122.75 2 16
4 13 1083.52 18 15.01 1801 487 3.08 / 123.24 2 12
5 13 457.68 18 15.18 939 257 3.34 / 123.49 2 12
6 13 51.24 18 15.27 349 96 3.44 / 123.59 2 10
7 8 0.04 165 15.24 272 684 4.12 / 124.27 2 19
Average= 4.01
(KJ/cycle)

Cycle 29 GMT 30/ 8/2023 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 37 15.17 408 229 0.23 / 116.24 2 4
2 7 2008.76 38 14.85 2958 1669 1.90 / 117.91 2 7
3 13 1684.48 18 14.90 2577 691 2.59 / 118.60 2 13
4 13 1109.04 18 14.99 1826 493 3.08 / 119.09 2 11
5 13 513.40 18 15.13 1020 278 3.36 / 119.37 2 12
6 13 64.76 18 15.26 367 101 3.46 / 119.47 2 10
7 8 -0.04 165 15.24 271 681 4.14 / 120.15 2 22
Average= 4.01
(KJ/cycle)

Cycle 28 GMT 21/ 8/2023 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 37 15.21 411 231 0.23 / 112.05 2 3
2 7 2023.92 39 14.84 2989 1730 1.96 / 113.78 2 10
3 13 1599.00 18 14.91 2469 663 2.62 / 114.44 2 12
4 13 1128.88 18 14.97 1856 500 3.12 / 114.94 2 13
5 13 517.08 18 15.14 1027 280 3.40 / 115.22 2 14
6 13 59.00 18 15.25 361 99 3.50 / 115.32 2 10
7 8 0.12 165 15.23 274 689 4.19 / 116.01 2 15
Average= 4.00
(KJ/cycle)

Cycle 27 GMT 11/ 8/2023 8:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 37 15.20 433 244 0.24 / 107.99 2 4
2 7 2006.24 38 14.87 2953 1669 1.91 / 109.66 2 10
3 13 1559.08 18 14.93 2411 648 2.56 / 110.31 2 16
4 13 1042.56 18 15.05 1737 471 3.03 / 110.78 2 13
5 13 491.12 18 15.18 988 270 3.30 / 111.05 2 14
6 13 38.60 18 15.28 329 90 3.39 / 111.14 2 8
7 8 0.88 165 15.26 271 682 4.07 / 111.82 2 23
Average= 3.99
(KJ/cycle)

Cycle 26 GMT 1/ 8/2023 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 37 15.20 398 224 0.22 / 103.87 2 3
2 7 2021.00 38 14.87 2987 1688 1.91 / 105.55 2 7
3 13 1653.52 18 14.92 2545 683 2.60 / 106.24 2 17
4 13 1034.28 18 15.05 1742 472 3.07 / 106.71 2 11
5 13 421.52 18 15.20 892 244 3.31 / 106.95 2 12
6 13 70.64 18 15.27 381 105 3.42 / 107.06 2 10
7 8 0.24 165 15.25 273 687 4.10 / 107.75 2 20
Average= 3.99
(KJ/cycle)

Cycle 25 GMT 22/ 7/2023 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 37 15.21 424 239 0.24 / 99.74 2 5
2 7 2007.20 38 14.88 2974 1682 1.92 / 101.42 2 9
3 13 1651.32 18 14.93 2538 682 2.60 / 102.11 2 11
4 13 1100.52 18 15.02 1823 493 3.10 / 102.60 2 11
5 13 461.16 18 15.19 948 259 3.35 / 102.86 2 13
6 13 53.68 18 15.27 353 97 3.45 / 102.96 2 7
7 8 -0.12 165 15.25 273 687 4.14 / 103.64 2 20
Average= 3.99
(KJ/cycle)

Cycle 24 GMT 13/ 7/2023 0:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 37 15.20 411 231 0.23 / 95.64 2 3
2 7 2009.52 39 14.87 2960 1717 1.95 / 97.36 2 8
3 13 1525.88 18 14.96 2373 639 2.59 / 98.00 2 11
4 13 1013.60 18 15.05 1700 461 3.05 / 98.46 2 12
5 13 465.08 18 15.17 951 260 3.31 / 98.72 2 13
6 13 51.76 18 15.28 353 97 3.40 / 98.81 2 9
7 8 -0.32 165 15.26 274 690 4.09 / 99.50 2 21
Average= 3.98
(KJ/cycle)

Cycle 23 GMT 3/ 7/2023 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 37 15.21 429 241 0.24 / 91.46 2 3
2 7 2006.44 38 14.87 2965 1675 1.92 / 93.13 2 7
3 13 1706.24 18 14.92 2606 700 2.62 / 93.83 2 15
4 13 1194.88 18 15.00 1950 526 3.14 / 94.36 2 12
5 13 476.88 18 15.18 971 265 3.41 / 94.62 2 12
6 13 62.52 18 15.27 369 101 3.51 / 94.73 2 10
7 8 -0.16 165 15.25 272 684 4.19 / 95.41 2 20
Average= 3.98
(KJ/cycle)

Cycle 22 GMT 23/ 6/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 37 15.22 407 229 0.23 / 87.35 2 4
2 7 2008.60 39 14.87 2963 1718 1.95 / 89.07 2 12
3 13 1625.96 18 14.93 2493 670 2.62 / 89.74 2 11
4 13 1010.28 18 15.04 1693 458 3.08 / 90.20 2 11
5 13 404.68 18 15.20 865 237 3.31 / 90.44 2 13
6 13 49.88 18 15.27 348 96 3.41 / 90.53 2 11
7 8 0.32 165 15.25 272 684 4.09 / 91.22 2 24
Average= 3.97
(KJ/cycle)

Cycle 21 GMT 13/ 6/2023 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 37 15.23 407 229 0.23 / 83.21 2 3
2 7 2023.48 39 14.89 2993 1738 1.97 / 84.95 2 11
3 13 1558.52 18 14.97 2424 653 2.62 / 85.60 2 13
4 13 1114.52 18 15.04 1846 500 3.12 / 86.10 2 12
5 13 418.48 18 15.21 885 242 3.36 / 86.34 2 13
6 13 43.80 18 15.30 341 94 3.46 / 86.44 2 9
7 8 0.76 165 15.27 272 685 4.14 / 87.12 2 17
Average= 3.96
(KJ/cycle)

Cycle 20 GMT 3/ 6/2023 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 37 15.21 407 229 0.23 / 79.09 2 4
2 7 2007.32 38 14.91 2979 1688 1.92 / 80.78 2 12
3 13 1611.84 18 14.97 2498 673 2.59 / 81.45 2 12
4 13 1080.96 18 15.04 1801 488 3.08 / 81.94 2 12
5 13 461.80 18 15.21 950 260 3.34 / 82.20 2 12
6 13 59.48 18 15.28 364 100 3.44 / 82.30 2 11
7 8 0.16 165 15.27 271 683 4.12 / 82.98 2 20
Average= 3.95
(KJ/cycle)

Cycle 19 GMT 25/ 5/2023 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 37 15.22 414 233 0.23 / 75.00 2 3
2 7 2018.40 38 14.90 2982 1688 1.92 / 76.69 2 11
3 13 1561.00 18 14.97 2426 654 2.58 / 77.35 2 11
4 13 1066.80 18 15.05 1772 480 3.06 / 77.83 2 12
5 13 432.76 18 15.22 905 248 3.30 / 78.07 2 13
6 13 49.92 18 15.30 353 97 3.40 / 78.17 2 11
7 8 0.28 165 15.27 274 690 4.09 / 78.86 2 21
Average= 3.94
(KJ/cycle)

Cycle 18 GMT 15/ 5/2023 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 37 15.22 406 229 0.23 / 70.81 2 4
2 7 2025.00 39 14.88 3002 1742 1.97 / 72.55 2 8
3 13 1591.68 18 14.96 2476 667 2.64 / 73.22 2 11
4 13 1074.52 18 15.04 1797 486 3.12 / 73.70 2 14
5 13 513.52 18 15.18 1024 280 3.40 / 73.98 2 14
6 13 47.72 18 15.31 350 96 3.50 / 74.08 2 9
7 8 0.20 165 15.28 274 691 4.19 / 74.77 2 21
Average= 3.94
(KJ/cycle)

Cycle 17 GMT 5/ 5/2023 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 37 15.23 410 231 0.23 / 66.66 2 3
2 7 2009.64 38 14.90 2974 1684 1.91 / 68.35 2 9
3 13 1584.60 18 14.96 2450 660 2.57 / 69.01 2 16
4 13 1241.52 18 15.00 2007 542 3.12 / 69.55 2 13
5 13 416.76 18 15.21 887 243 3.36 / 69.79 2 14
6 13 50.00 18 15.31 350 96 3.46 / 69.89 2 11
7 8 0.28 165 15.27 274 690 4.15 / 70.58 2 12
Average= 3.92
(KJ/cycle)

Cycle 16 GMT 25/ 4/2023 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 37 15.23 407 229 0.23 / 62.59 2 3
2 7 2009.40 38 14.90 2971 1682 1.91 / 64.27 2 10
3 13 1627.36 18 14.96 2506 675 2.59 / 64.95 2 10
4 13 1031.96 18 15.06 1733 470 3.06 / 65.42 2 12
5 13 374.12 18 15.24 828 227 3.28 / 65.64 2 14
6 13 51.44 18 15.30 356 98 3.38 / 65.74 2 9
7 8 0.52 165 15.27 274 690 4.07 / 66.43 2 20
Average= 3.91
(KJ/cycle)

Cycle 15 GMT 16/ 4/2023 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 37 15.23 403 227 0.23 / 58.40 2 3
2 7 2021.28 39 14.91 2994 1741 1.97 / 60.14 2 10
3 13 1657.64 18 14.97 2547 686 2.65 / 60.83 2 13
4 13 1049.96 18 15.07 1757 477 3.13 / 61.30 2 12
5 13 454.32 18 15.21 941 258 3.39 / 61.56 2 14
6 13 49.44 18 15.31 353 97 3.49 / 61.66 2 13
7 8 -0.04 165 15.27 279 703 4.19 / 62.36 2 15
Average= 3.90
(KJ/cycle)

Cycle 14 GMT 6/ 4/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 37 15.22 410 231 0.23 / 54.35 2 3
2 7 2006.20 39 14.91 2970 1727 1.96 / 56.08 2 9
3 13 1483.28 18 15.00 2330 629 2.59 / 56.71 2 11
4 13 1003.40 18 15.08 1700 461 3.05 / 57.17 2 13
5 13 326.80 18 15.27 762 209 3.26 / 57.38 2 14
6 13 36.28 18 15.32 335 92 3.35 / 57.47 2 9
7 8 -0.12 165 15.28 277 698 4.05 / 58.17 2 18
Average= 3.88
(KJ/cycle)

Cycle 13 GMT 27/ 3/2023 11:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 36 15.23 432 237 0.24 / 50.21 2 3
2 7 2022.32 38 14.91 2993 1696 1.93 / 51.90 2 9
3 13 1523.36 18 14.97 2374 640 2.57 / 52.54 2 11
4 13 967.44 18 15.08 1648 447 3.02 / 52.99 2 12
5 13 476.00 18 15.19 973 266 3.29 / 53.26 2 14
6 13 196.68 18 15.27 575 158 3.44 / 53.42 2 13
7 8 0.00 165 15.27 281 708 4.15 / 54.12 2 19
Average= 3.87
(KJ/cycle)

Cycle 12 GMT 17/ 3/2023 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 36 15.24 414 227 0.23 / 46.11 2 3
2 7 2018.32 38 14.91 2991 1695 1.92 / 47.80 2 9
3 13 1553.36 18 14.99 2419 653 2.57 / 48.46 2 11
4 13 1029.52 18 15.06 1734 470 3.04 / 48.93 2 13
5 13 441.36 18 15.23 928 254 3.30 / 49.18 2 14
6 13 42.36 18 15.32 342 94 3.39 / 49.28 2 11
7 8 0.56 165 15.29 276 696 4.09 / 49.97 2 18
Average= 3.84
(KJ/cycle)

Cycle 11 GMT 7/ 3/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 36 15.25 413 227 0.23 / 42.00 2 4
2 7 2019.32 38 14.92 2974 1686 1.91 / 43.69 2 9
3 13 1633.08 18 14.97 2507 676 2.59 / 44.36 2 17
4 13 1035.44 18 15.07 1733 470 3.06 / 44.83 2 12
5 13 482.40 18 15.22 980 268 3.33 / 45.10 2 13
6 13 32.92 18 15.32 329 91 3.42 / 45.19 2 10
7 8 -0.32 165 15.29 273 689 4.11 / 45.88 2 19
Average= 3.82
(KJ/cycle)

Cycle 10 GMT 26/ 2/2023 3:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 36 15.27 405 223 0.22 / 37.93 2 3
2 7 2006.04 38 14.95 2971 1688 1.91 / 39.62 2 7
3 13 1584.16 18 15.01 2444 660 2.57 / 40.28 2 11
4 13 1048.84 18 15.09 1751 476 3.05 / 40.75 2 14
5 13 405.28 18 15.25 869 239 3.28 / 40.99 2 12
6 13 29.48 18 15.33 322 89 3.37 / 41.08 2 12
7 8 0.04 165 15.30 275 694 4.07 / 41.78 2 18
Average= 3.80
(KJ/cycle)

Cycle 9 GMT 16/ 2/2023 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 36 15.26 442 243 0.24 / 33.78 2 3
2 7 2023.08 38 14.95 3006 1708 1.95 / 35.49 2 8
3 13 1696.72 18 15.00 2617 707 2.66 / 36.19 2 12
4 13 1018.12 18 15.11 1721 468 3.13 / 36.66 2 13
5 13 430.68 18 15.27 910 250 3.38 / 36.91 2 13
6 13 29.24 18 15.35 327 90 3.47 / 37.00 2 10
7 8 0.36 165 15.32 280 708 4.17 / 37.71 2 20
Average= 3.77
(KJ/cycle)

Cycle 8 GMT 6/ 2/2023 14:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 36 15.26 438 241 0.24 / 29.65 2 4
2 3 1024.16 1 15.29 1782 27 0.27 / 29.68 2 7
3 7 2017.92 38 14.95 2991 1699 1.97 / 31.38 2 8
4 13 1604.32 18 15.00 2485 671 2.64 / 32.05 2 10
5 13 1004.76 18 15.11 1696 461 3.10 / 32.51 2 12
6 13 376.44 18 15.26 832 229 3.33 / 32.74 2 13
7 13 33.96 18 15.33 333 92 3.42 / 32.83 2 10
8 8 0.08 165 15.31 278 702 4.12 / 33.53 2 22
Average= 3.73
(KJ/cycle)

Cycle 7 GMT 27/ 1/2023 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 34 15.25 442 229 0.23 / 24.86 2 3
2 10 1034.12 2 15.24 1784 54 0.28 / 24.92 2 10
3 7 2021.16 74 14.83 2975 3265 3.55 / 28.18 2 10
4 13 763.48 18 15.17 1371 374 3.92 / 28.56 2 14
5 13 150.60 18 15.32 510 141 4.06 / 28.70 2 13
6 8 0.52 165 15.32 283 715 4.78 / 29.41 2 15
Average= 3.68
(KJ/cycle)

Cycle 6 GMT 17/ 1/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 27 15.24 447 184 0.18 / 19.96 2 3
2 10 1052.68 4 15.20 1810 110 0.29 / 20.07 2 7
3 10 1086.32 2 15.21 1867 57 0.35 / 20.12 2 9
4 3 1080.80 2 15.25 1882 57 0.41 / 20.18 2 9
5 7 2016.40 74 14.83 2981 3271 3.68 / 23.45 2 10
6 13 622.68 18 15.20 1178 322 4.00 / 23.77 2 13
7 13 167.48 18 15.31 533 147 4.15 / 23.92 2 14
8 8 -0.08 165 15.32 282 713 4.86 / 24.63 2 19
Average= 3.52
(KJ/cycle)

Cycle 5 GMT 8/ 1/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 29 15.28 431 191 0.19 / 15.36 2 3
2 3 945.68 -1 15.64 1 0 0.00 / 15.36 2 3
3 7 2014.32 74 14.82 2960 3246 3.44 / 18.61 2 10
4 13 599.96 18 15.20 1140 312 3.75 / 18.92 2 14
5 13 137.32 18 15.31 482 133 3.88 / 19.05 2 11
6 8 0.12 165 15.29 285 719 4.60 / 19.77 2 16
Average= 3.30
(KJ/cycle)

Cycle 4 GMT 29/12/2022 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 27 15.28 434 179 0.18 / 11.69 2 3
2 7 1510.60 74 14.99 2335 2590 2.77 / 14.28 2 13
3 13 239.36 18 15.32 637 176 2.94 / 14.45 2 12
4 8 -0.08 165 15.33 284 718 3.66 / 15.17 2 19
Average= 3.03
(KJ/cycle)

Cycle 3 GMT 28/12/2022 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 25 15.29 428 164 0.16 / 8.03 2 4
2 10 1030.08 2 15.27 1760 54 0.22 / 8.08 2 8
3 7 1507.00 74 15.00 2324 2580 2.80 / 10.66 2 11
4 13 140.52 18 15.34 490 135 2.93 / 10.80 2 12
5 8 -0.08 165 15.33 281 711 3.64 / 11.51 2 14
Average= 2.88
(KJ/cycle)

Cycle 2 GMT 27/12/2022 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 15.31 433 206 0.21 / 4.44 2 4
2 3 794.12 -4 15.66 0 0 0.00 / 4.44 2 4
3 3 939.00 -1 15.68 0 0 0.00 / 4.44 2 4
4 7 1508.44 74 15.00 2325 2581 2.79 / 7.02 2 8
5 13 149.40 18 15.34 497 137 2.92 / 7.16 2 12
6 8 0.24 165 15.34 278 704 3.63 / 7.87 2 20
Average= 2.62
(KJ/cycle)

Cycle 1 GMT 26/12/2022 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 26 15.50 395 159 0.16 / 1.67 2 3
2 7 991.52 74 15.17 1636 1837 2.00 / 3.51 2 11
3 8 -0.04 165 15.37 287 728 2.72 / 4.24 2 17
Average= 2.12
(KJ/cycle)

Cycle 0 GMT 25/12/2022 20:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 97.72 26 15.62 385 156 0.16 / 0.16 2 3
2 7 112.92 74 15.60 403 465 0.62 / 0.62 2 3
3 8 0.40 240 15.57 239 893 1.51 / 1.51 2 18
Average= 1.51
(KJ/cycle)