SIO Argo Site:
Pump Diagnostics Page   



Serial= 3145 WMO= 3902287

Return

←PreviousNext→

Cycle 76 GMT 30/11/2024 16:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 42 15.07 439 278 0.28 / 329.02 2 2
2 7 2011.44 38 14.82 2893 1629 1.91 / 330.65 2 6
3 13 1798.80 18 14.81 2657 708 2.62 / 331.36 2 8
4 13 1246.24 18 14.86 1978 529 3.14 / 331.89 2 9
5 13 589.52 18 14.98 1131 305 3.45 / 332.20 2 10
6 13 154.64 18 15.10 534 145 3.59 / 332.34 2 9
7 8 0.04 165 15.10 300 747 4.34 / 333.09 2 13
Average= 4.33
(KJ/cycle)

Cycle 75 GMT 20/11/2024 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 42 15.06 441 279 0.28 / 324.66 2 3
2 7 2010.32 39 14.84 2895 1676 1.95 / 326.33 2 6
3 13 1677.28 18 14.84 2518 673 2.63 / 327.01 2 7
4 13 1240.04 18 14.86 1970 527 3.15 / 327.53 2 8
5 13 640.48 18 14.99 1195 322 3.48 / 327.86 2 10
6 13 146.28 18 15.10 521 142 3.62 / 328.00 2 9
7 8 0.12 165 15.11 300 748 4.37 / 328.75 2 11
Average= 4.33
(KJ/cycle)

Cycle 74 GMT 11/11/2024 3:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 41 15.08 462 286 0.29 / 320.30 2 2
2 7 2010.56 38 14.82 2898 1632 1.92 / 321.93 2 7
3 13 1760.56 18 14.82 2597 693 2.61 / 322.62 2 8
4 13 1227.04 18 14.87 1949 522 3.13 / 323.14 2 10
5 13 682.08 18 14.97 1254 338 3.47 / 323.48 2 9
6 13 155.92 18 15.11 537 146 3.62 / 323.63 2 10
7 8 0.08 165 15.12 302 753 4.37 / 324.38 2 14
Average= 4.33
(KJ/cycle)

Cycle 73 GMT 1/11/2024 8:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 41 15.06 446 275 0.28 / 315.92 2 3
2 7 2008.28 39 14.84 2908 1683 1.96 / 317.60 2 5
3 13 1754.56 18 14.83 2597 693 2.65 / 318.29 2 7
4 13 1188.52 18 14.88 1903 510 3.16 / 318.80 2 9
5 13 603.24 18 15.02 1150 311 3.47 / 319.11 2 10
6 13 147.92 18 15.13 525 143 3.62 / 319.26 2 10
7 8 0.00 165 15.13 302 754 4.37 / 320.01 2 24
Average= 4.32
(KJ/cycle)

Cycle 72 GMT 22/10/2024 14: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 41 15.07 446 276 0.28 / 311.51 2 3
2 7 2024.84 38 14.82 2920 1644 1.92 / 313.16 2 8
3 13 1807.56 18 14.82 2665 711 2.63 / 313.87 2 7
4 13 1224.08 18 14.86 1952 522 3.15 / 314.39 2 8
5 13 677.80 18 14.98 1246 336 3.49 / 314.73 2 10
6 13 164.96 18 15.12 551 150 3.64 / 314.88 2 9
7 8 0.08 165 15.11 306 763 4.40 / 315.64 2 13
Average= 4.32
(KJ/cycle)

Cycle 71 GMT 12/10/2024 19:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 41 15.09 445 275 0.28 / 307.09 2 3
2 7 2010.16 38 14.84 2895 1633 1.91 / 308.72 2 8
3 13 1971.88 18 14.82 2848 760 2.67 / 309.48 2 6
4 13 1237.32 18 14.88 1956 524 3.19 / 310.01 2 8
5 13 688.04 18 14.99 1257 339 3.53 / 310.35 2 10
6 13 145.12 18 15.13 516 141 3.67 / 310.49 2 9
7 8 0.12 165 15.14 301 752 4.42 / 311.24 2 19
Average= 4.32
(KJ/cycle)

Cycle 70 GMT 3/10/2024 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 41 15.08 442 273 0.27 / 302.63 2 3
2 7 2023.48 38 14.83 2904 1637 1.91 / 304.27 2 8
3 13 1985.72 18 14.80 2871 765 2.67 / 305.03 2 8
4 13 1226.84 18 14.88 1947 521 3.20 / 305.55 2 9
5 13 778.72 18 14.97 1372 370 3.57 / 305.92 2 10
6 13 147.48 18 15.14 524 143 3.71 / 306.06 2 9
7 8 0.04 165 15.13 301 751 4.46 / 306.82 2 14
Average= 4.32
(KJ/cycle)

Cycle 69 GMT 23/ 9/2024 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 41 15.10 437 271 0.27 / 298.16 2 3
2 7 2024.52 38 14.83 2916 1643 1.91 / 299.80 2 7
3 13 1989.04 18 14.81 2876 767 2.68 / 300.57 2 9
4 13 1239.52 18 14.89 1963 526 3.21 / 301.10 2 9
5 13 747.40 18 14.97 1334 359 3.57 / 301.45 2 9
6 13 172.48 18 15.13 558 152 3.72 / 301.61 2 9
7 8 0.00 165 15.14 300 749 4.47 / 302.36 2 13
Average= 4.32
(KJ/cycle)

Cycle 68 GMT 13/ 9/2024 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 41 15.09 438 271 0.27 / 293.74 2 3
2 7 2025.28 38 14.83 2916 1643 1.91 / 295.39 2 8
3 13 1985.92 18 14.82 2873 766 2.68 / 296.15 2 7
4 13 1207.52 18 14.90 1926 517 3.20 / 296.67 2 8
5 13 683.96 18 15.01 1248 337 3.53 / 297.01 2 9
6 13 126.76 18 15.15 493 134 3.67 / 297.14 2 9
7 8 0.04 165 15.15 299 747 4.42 / 297.89 2 17
Average= 4.32
(KJ/cycle)

Cycle 67 GMT 3/ 9/2024 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 41 15.11 436 270 0.27 / 289.30 2 3
2 7 2008.60 38 14.86 2894 1634 1.90 / 290.94 2 9
3 13 1798.68 18 14.84 2643 706 2.61 / 291.64 2 9
4 13 1202.96 18 14.90 1921 515 3.13 / 292.16 2 8
5 13 629.84 18 15.02 1183 320 3.45 / 292.48 2 10
6 13 178.16 18 15.14 565 154 3.60 / 292.63 2 9
7 13 15.56 18 15.17 330 90 3.69 / 292.72 2 9
8 8 0.04 165 15.14 300 749 4.44 / 293.47 2 16
Average= 4.32
(KJ/cycle)

Cycle 66 GMT 24/ 8/2024 20:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 41 15.12 449 278 0.28 / 284.98 2 3
2 7 2012.52 38 14.84 2890 1630 1.91 / 286.61 2 6
3 13 1720.48 18 14.84 2547 680 2.59 / 287.29 2 7
4 13 1187.60 18 14.90 1901 510 3.10 / 287.80 2 10
5 13 680.56 18 15.01 1245 336 3.43 / 288.14 2 10
6 13 157.04 18 15.15 538 147 3.58 / 288.28 2 10
7 8 0.24 165 15.14 300 749 4.33 / 289.03 2 14
Average= 4.31
(KJ/cycle)

Cycle 65 GMT 15/ 8/2024 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 41 15.11 446 276 0.28 / 280.55 2 3
2 7 2015.96 38 14.86 2899 1637 1.91 / 282.18 2 5
3 13 1978.12 18 14.84 2864 765 2.68 / 282.95 2 9
4 13 1217.40 18 14.91 1938 520 3.20 / 283.47 2 9
5 13 684.20 18 15.03 1251 338 3.54 / 283.81 2 10
6 13 135.20 18 15.17 507 138 3.68 / 283.94 2 8
7 8 0.04 165 15.16 303 758 4.43 / 284.70 2 14
Average= 4.31
(KJ/cycle)

Cycle 64 GMT 5/ 8/2024 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 41 15.11 448 278 0.28 / 276.20 2 3
2 7 2016.20 38 14.85 2903 1638 1.92 / 277.84 2 8
3 13 1767.20 18 14.85 2610 698 2.61 / 278.54 2 7
4 13 1222.36 18 14.91 1945 522 3.14 / 279.06 2 8
5 13 602.96 18 15.04 1145 310 3.45 / 279.37 2 10
6 13 153.28 18 15.16 530 145 3.59 / 279.51 2 9
7 8 0.04 165 15.16 303 758 4.35 / 280.27 2 15
Average= 4.31
(KJ/cycle)

Cycle 63 GMT 26/ 7/2024 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 41 15.12 439 272 0.27 / 271.85 2 3
2 7 2019.84 38 14.85 2912 1643 1.92 / 273.49 2 6
3 13 1703.28 18 14.85 2530 676 2.59 / 274.17 2 8
4 13 1156.08 18 14.93 1853 498 3.09 / 274.66 2 9
5 13 712.00 18 15.02 1289 348 3.44 / 275.01 2 10
6 13 178.20 18 15.16 566 154 3.59 / 275.17 2 9
7 8 0.04 165 15.16 302 755 4.35 / 275.92 2 13
Average= 4.31
(KJ/cycle)

Cycle 62 GMT 16/ 7/2024 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 41 15.13 445 276 0.28 / 267.51 2 3
2 7 2015.40 38 14.86 2901 1638 1.91 / 269.15 2 6
3 13 1713.44 18 14.86 2551 682 2.60 / 269.83 2 7
4 13 1227.84 18 14.92 1947 523 3.12 / 270.35 2 9
5 13 666.36 18 15.03 1230 333 3.45 / 270.69 2 10
6 13 115.32 18 15.19 472 129 3.58 / 270.82 2 8
7 8 0.08 165 15.17 303 758 4.34 / 271.57 2 13
Average= 4.31
(KJ/cycle)

Cycle 61 GMT 6/ 7/2024 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 41 15.13 434 269 0.27 / 263.16 2 3
2 7 2020.40 38 14.87 2912 1645 1.91 / 264.81 2 6
3 13 1768.24 18 14.86 2614 699 2.61 / 265.51 2 7
4 13 1187.68 18 14.92 1894 509 3.12 / 266.02 2 9
5 13 656.04 18 15.05 1209 328 3.45 / 266.34 2 10
6 13 150.40 18 15.17 524 143 3.59 / 266.49 2 10
7 8 0.12 165 15.18 298 746 4.34 / 267.23 2 10
Average= 4.31
(KJ/cycle)

Cycle 60 GMT 27/ 6/2024 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 41 15.14 445 276 0.28 / 258.59 2 3
2 7 2025.68 39 14.85 2916 1689 1.97 / 260.28 2 6
3 13 1986.48 18 14.83 2868 766 2.73 / 261.04 2 8
4 13 1257.16 18 14.91 1985 533 3.26 / 261.58 2 8
5 13 664.88 18 15.05 1223 331 3.59 / 261.91 2 10
6 13 155.48 18 15.20 535 146 3.74 / 262.06 2 9
7 13 30.24 18 15.20 348 95 3.84 / 262.15 2 8
8 8 0.16 165 15.18 297 744 4.58 / 262.89 2 15
Average= 4.31
(KJ/cycle)

Cycle 59 GMT 17/ 6/2024 10:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 41 15.14 442 274 0.27 / 254.10 2 3
2 7 2018.12 38 14.87 2908 1643 1.92 / 255.74 2 7
3 13 1979.76 18 14.84 2871 767 2.68 / 256.51 2 7
4 13 1211.44 18 14.95 1931 520 3.20 / 257.03 2 9
5 13 591.64 18 15.08 1129 306 3.51 / 257.33 2 10
6 13 139.72 18 15.19 511 140 3.65 / 257.47 2 9
7 13 22.04 18 15.22 337 92 3.74 / 257.57 2 6
8 8 0.00 165 15.18 299 749 4.49 / 258.31 2 13
Average= 4.31
(KJ/cycle)

Cycle 58 GMT 7/ 6/2024 16:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 41 15.16 449 279 0.28 / 249.48 2 3
2 7 2027.44 39 14.85 2917 1689 1.97 / 251.17 2 5
3 13 1988.00 18 14.84 2869 766 2.73 / 251.93 2 7
4 13 1244.68 18 14.94 1978 532 3.27 / 252.46 2 8
5 13 731.12 18 15.04 1320 357 3.62 / 252.82 2 10
6 13 164.08 18 15.19 550 150 3.77 / 252.97 2 9
7 13 27.76 18 15.22 349 96 3.87 / 253.07 2 8
8 8 0.08 165 15.20 301 755 4.63 / 253.82 2 13
Average= 4.30
(KJ/cycle)

Cycle 57 GMT 28/ 5/2024 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 41 15.15 442 275 0.27 / 245.09 2 2
2 7 2007.92 38 14.88 2900 1640 1.91 / 246.73 2 7
3 13 1755.12 18 14.88 2609 699 2.61 / 247.43 2 8
4 13 1178.16 18 14.96 1886 508 3.12 / 247.93 2 9
5 13 733.72 18 15.03 1319 357 3.48 / 248.29 2 10
6 13 160.68 18 15.19 546 149 3.63 / 248.44 2 9
7 8 0.04 165 15.20 302 757 4.38 / 249.20 2 17
Average= 4.30
(KJ/cycle)

Cycle 56 GMT 19/ 5/2024 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 41 15.15 440 273 0.27 / 240.66 2 2
2 7 2016.04 38 14.88 2900 1640 1.91 / 242.30 2 7
3 13 1977.36 18 14.85 2852 762 2.68 / 243.06 2 7
4 13 1189.96 18 14.97 1898 511 3.19 / 243.58 2 9
5 13 674.68 18 15.07 1237 336 3.52 / 243.91 2 10
6 13 163.48 18 15.20 545 149 3.67 / 244.06 2 10
7 8 0.00 165 15.21 300 753 4.42 / 244.81 2 15
Average= 4.29
(KJ/cycle)

Cycle 55 GMT 9/ 5/2024 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 41 15.17 449 279 0.28 / 236.33 2 3
2 7 2018.28 38 14.88 2904 1642 1.92 / 237.97 2 5
3 13 1720.76 18 14.89 2552 684 2.61 / 238.66 2 7
4 13 1202.04 18 14.94 1914 515 3.12 / 239.17 2 8
5 13 652.56 18 15.07 1212 329 3.45 / 239.50 2 10
6 13 131.40 18 15.20 502 137 3.59 / 239.64 2 9
7 8 0.04 165 15.19 299 749 4.34 / 240.39 2 15
Average= 4.29
(KJ/cycle)

Cycle 54 GMT 29/ 4/2024 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 41 15.15 449 279 0.28 / 231.88 2 2
2 7 2018.72 38 14.89 2908 1645 1.92 / 233.53 2 5
3 13 1980.32 18 14.86 2858 764 2.69 / 234.29 2 6
4 13 1216.24 18 14.97 1935 521 3.21 / 234.82 2 8
5 13 607.04 18 15.10 1154 314 3.52 / 235.13 2 10
6 13 202.92 18 15.20 606 166 3.69 / 235.30 2 10
7 8 0.04 165 15.21 302 758 4.45 / 236.05 2 12
Average= 4.29
(KJ/cycle)

Cycle 53 GMT 19/ 4/2024 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 41 15.16 438 272 0.27 / 227.32 2 3
2 7 2013.72 39 14.89 2900 1684 1.96 / 229.00 2 6
3 13 1974.64 18 14.87 2860 766 2.72 / 229.77 2 7
4 13 1246.60 18 14.97 1974 532 3.25 / 230.30 2 8
5 13 576.20 18 15.11 1113 303 3.56 / 230.60 2 9
6 13 170.68 18 15.21 559 153 3.71 / 230.76 2 10
7 13 15.52 18 15.24 332 91 3.80 / 230.85 2 10
8 8 -0.04 165 15.21 302 758 4.56 / 231.61 2 12
Average= 4.29
(KJ/cycle)

Cycle 52 GMT 10/ 4/2024 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 41 15.14 449 279 0.28 / 222.98 2 3
2 7 2014.08 38 14.90 2900 1642 1.92 / 224.62 2 6
3 13 1707.00 18 14.92 2533 680 2.60 / 225.30 2 7
4 13 1215.08 18 14.96 1933 521 3.12 / 225.82 2 9
5 13 614.64 18 15.10 1163 316 3.44 / 226.14 2 10
6 13 154.48 18 15.21 540 148 3.59 / 226.29 2 9
7 8 0.16 165 15.21 303 760 4.35 / 227.05 2 13
Average= 4.28
(KJ/cycle)

Cycle 51 GMT 31/ 3/2024 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 41 15.17 448 279 0.28 / 218.57 2 3
2 7 2007.52 38 14.89 2903 1643 1.92 / 220.21 2 7
3 13 1797.00 18 14.89 2648 710 2.63 / 220.92 2 7
4 13 1197.48 18 14.96 1912 515 3.15 / 221.44 2 9
5 13 644.76 18 15.08 1201 326 3.47 / 221.76 2 10
6 13 211.76 18 15.19 623 170 3.64 / 221.93 2 10
7 8 0.16 165 15.20 307 770 4.41 / 222.70 2 12
Average= 4.28
(KJ/cycle)

Cycle 50 GMT 21/ 3/2024 12:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 41 15.16 440 273 0.27 / 214.20 2 3
2 7 2008.04 38 14.89 2894 1637 1.91 / 215.84 2 6
3 13 1756.08 18 14.91 2608 700 2.61 / 216.54 2 8
4 13 1124.80 18 14.99 1818 491 3.10 / 217.03 2 9
5 13 688.44 18 15.07 1258 341 3.44 / 217.37 2 10
6 13 156.88 18 15.21 543 149 3.59 / 217.52 2 10
7 8 0.04 165 15.21 306 768 4.36 / 218.29 2 16
Average= 4.28
(KJ/cycle)

Cycle 49 GMT 11/ 3/2024 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 41 15.16 447 278 0.28 / 209.85 2 3
2 7 2023.92 38 14.89 2912 1648 1.93 / 211.50 2 6
3 13 1716.80 18 14.92 2545 683 2.61 / 212.18 2 7
4 13 1197.44 18 14.99 1907 515 3.12 / 212.70 2 10
5 13 613.60 18 15.10 1159 315 3.44 / 213.01 2 10
6 13 191.08 18 15.22 586 161 3.60 / 213.17 2 9
7 8 0.00 165 15.22 302 758 4.36 / 213.93 2 16
Average= 4.28
(KJ/cycle)

Cycle 48 GMT 1/ 3/2024 23: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 41 15.15 435 270 0.27 / 205.48 2 3
2 7 2010.08 39 14.89 2892 1679 1.95 / 207.16 2 6
3 13 1694.76 18 14.90 2517 675 2.62 / 207.84 2 7
4 13 1199.52 18 14.97 1917 517 3.14 / 208.35 2 9
5 13 590.00 18 15.10 1133 308 3.45 / 208.66 2 10
6 13 168.36 18 15.21 554 152 3.60 / 208.81 2 10
7 8 0.04 165 15.21 303 760 4.36 / 209.57 2 15
Average= 4.28
(KJ/cycle)

Cycle 47 GMT 21/ 2/2024 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 41 15.18 448 279 0.28 / 201.13 2 3
2 7 2008.80 38 14.89 2889 1635 1.91 / 202.76 2 7
3 13 1747.04 18 14.90 2579 692 2.61 / 203.46 2 8
4 13 1218.32 18 14.97 1938 522 3.13 / 203.98 2 9
5 13 659.92 18 15.10 1221 332 3.46 / 204.31 2 10
6 13 137.84 18 15.23 506 139 3.60 / 204.45 2 9
7 8 0.04 165 15.21 304 763 4.36 / 205.21 2 19
Average= 4.28
(KJ/cycle)

Cycle 46 GMT 11/ 2/2024 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 41 15.19 440 274 0.27 / 196.71 2 3
2 7 2024.32 38 14.89 2909 1646 1.92 / 198.36 2 7
3 13 1728.72 18 14.91 2560 687 2.61 / 199.04 2 8
4 13 1230.88 18 14.97 1957 527 3.13 / 199.57 2 9
5 13 719.00 18 15.07 1311 356 3.49 / 199.93 2 10
6 13 183.64 18 15.20 581 159 3.65 / 200.09 2 9
7 8 -0.04 165 15.21 305 765 4.41 / 200.85 2 16
Average= 4.27
(KJ/cycle)

Cycle 45 GMT 1/ 2/2024 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 41 15.18 435 271 0.27 / 192.42 2 3
2 7 2007.16 38 14.90 2892 1637 1.91 / 194.05 2 6
3 13 1753.84 18 14.93 2593 697 2.61 / 194.75 2 7
4 13 1133.36 18 15.01 1826 493 3.10 / 195.24 2 9
5 13 604.16 18 15.12 1150 313 3.41 / 195.56 2 10
6 13 114.44 18 15.25 470 129 3.54 / 195.68 2 8
7 8 0.16 165 15.23 299 751 4.29 / 196.44 2 12
Average= 4.27
(KJ/cycle)

Cycle 44 GMT 22/ 1/2024 20:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 41 15.19 447 278 0.28 / 188.06 2 3
2 7 2012.08 38 14.91 2901 1644 1.92 / 189.70 2 6
3 13 1796.16 18 14.91 2646 710 2.63 / 190.41 2 7
4 13 1174.16 18 14.99 1878 507 3.14 / 190.92 2 9
5 13 622.20 18 15.11 1165 317 3.46 / 191.23 2 10
6 13 162.80 18 15.22 546 150 3.61 / 191.38 2 8
7 8 0.12 165 15.22 303 761 4.37 / 192.14 2 14
Average= 4.27
(KJ/cycle)

Cycle 43 GMT 13/ 1/2024 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 41 15.17 450 280 0.28 / 183.72 2 3
2 7 2008.16 38 14.90 2893 1638 1.92 / 185.36 2 6
3 13 1749.96 18 14.91 2596 697 2.61 / 186.05 2 7
4 13 1208.88 18 14.99 1927 520 3.13 / 186.57 2 8
5 13 621.40 18 15.13 1173 319 3.45 / 186.89 2 9
6 13 113.60 18 15.24 473 130 3.58 / 187.02 2 8
7 8 0.04 165 15.23 301 756 4.34 / 187.78 2 17
Average= 4.27
(KJ/cycle)

Cycle 42 GMT 3/ 1/2024 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 41 15.19 452 282 0.28 / 179.36 2 3
2 10 1000.16 2 15.21 1723 52 0.33 / 179.41 2 6
3 3 949.88 -2 15.50 1 0 0.05 / 179.41 2 6
4 7 2017.24 38 14.91 2907 1647 1.98 / 181.06 2 7
5 13 1715.32 18 14.92 2545 683 2.66 / 181.74 2 7
6 13 1146.12 18 15.00 1843 498 3.16 / 182.24 2 10
7 13 567.12 18 15.13 1092 297 3.46 / 182.54 2 9
8 13 159.68 18 15.22 538 147 3.61 / 182.68 2 9
9 8 0.08 165 15.23 300 754 4.36 / 183.44 2 15
Average= 4.27
(KJ/cycle)

Cycle 41 GMT 24/12/2023 13: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 41 15.19 434 270 0.27 / 175.03 2 3
2 7 2018.52 38 14.92 2905 1647 1.92 / 176.68 2 6
3 13 1712.08 18 14.95 2545 685 2.60 / 177.36 2 8
4 13 1183.60 18 15.00 1893 511 3.11 / 177.87 2 8
5 13 567.28 18 15.14 1095 298 3.41 / 178.17 2 9
6 13 124.96 18 15.25 492 135 3.55 / 178.31 2 8
7 8 0.00 165 15.24 307 772 4.32 / 179.08 2 12
Average= 4.26
(KJ/cycle)

Cycle 40 GMT 14/12/2023 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 41 15.19 443 276 0.28 / 170.70 2 3
2 7 2009.04 38 14.91 2892 1639 1.91 / 172.34 2 6
3 13 1747.40 18 14.91 2581 693 2.61 / 173.03 2 7
4 13 1246.32 18 14.98 1961 529 3.14 / 173.56 2 8
5 13 604.32 18 15.12 1147 312 3.45 / 173.87 2 9
6 13 109.00 18 15.24 463 127 3.58 / 174.00 2 8
7 8 0.08 165 15.23 302 759 4.33 / 174.76 2 14
Average= 4.26
(KJ/cycle)

Cycle 39 GMT 4/12/2023 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 41 15.19 446 278 0.28 / 166.22 2 3
2 7 2020.52 38 14.92 2909 1649 1.93 / 167.87 2 6
3 13 1981.36 18 14.90 2862 768 2.69 / 168.64 2 6
4 13 1293.76 18 14.98 2034 548 3.24 / 169.19 2 9
5 13 601.76 18 15.15 1141 311 3.55 / 169.50 2 9
6 13 192.48 18 15.24 584 160 3.71 / 169.66 2 9
7 8 0.00 165 15.24 305 767 4.48 / 170.42 2 14
Average= 4.26
(KJ/cycle)

Cycle 38 GMT 25/11/2023 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 41 15.19 451 281 0.28 / 161.92 2 3
2 7 2006.96 38 14.93 2892 1641 1.92 / 163.57 2 6
3 13 1745.48 18 14.94 2590 697 2.62 / 164.26 2 7
4 13 1162.96 18 15.01 1864 504 3.12 / 164.77 2 9
5 13 551.44 18 15.16 1073 293 3.41 / 165.06 2 9
6 13 111.88 18 15.25 467 128 3.54 / 165.19 2 7
7 8 0.16 165 15.24 301 757 4.30 / 165.94 2 15
Average= 4.25
(KJ/cycle)

Cycle 37 GMT 15/11/2023 10:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 41 15.21 445 278 0.28 / 157.54 2 3
2 7 2019.12 38 14.93 2901 1646 1.92 / 159.18 2 7
3 13 1753.80 18 14.93 2595 697 2.62 / 159.88 2 7
4 13 1234.44 18 15.00 1955 528 3.15 / 160.41 2 9
5 13 631.28 18 15.13 1177 321 3.47 / 160.73 2 10
6 13 164.64 18 15.24 547 150 3.62 / 160.88 2 9
7 8 0.12 165 15.25 304 765 4.38 / 161.64 2 17
Average= 4.25
(KJ/cycle)

Cycle 36 GMT 5/11/2023 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 41 15.20 441 275 0.27 / 153.17 2 3
2 7 2010.60 38 14.93 2895 1642 1.92 / 154.81 2 6
3 13 1756.68 18 14.93 2593 697 2.61 / 155.51 2 9
4 13 1259.48 18 14.99 1984 535 3.15 / 156.05 2 10
5 13 614.52 18 15.13 1160 316 3.47 / 156.36 2 9
6 13 104.12 18 15.26 462 127 3.59 / 156.49 2 8
7 8 0.08 165 15.25 306 770 4.36 / 157.26 2 14
Average= 4.25
(KJ/cycle)

Cycle 35 GMT 26/10/2023 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 41 15.20 446 278 0.28 / 148.79 2 3
2 7 2006.92 38 14.92 2892 1640 1.92 / 150.43 2 5
3 13 1786.96 18 14.93 2637 709 2.63 / 151.14 2 9
4 13 1198.60 18 15.01 1910 516 3.14 / 151.66 2 8
5 13 619.48 18 15.14 1167 318 3.46 / 151.98 2 10
6 13 178.68 18 15.25 569 156 3.62 / 152.13 2 9
7 8 -0.04 165 15.25 304 765 4.38 / 152.90 2 16
Average= 4.25
(KJ/cycle)

Cycle 34 GMT 17/10/2023 3:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 41 15.20 464 289 0.29 / 144.40 2 3
2 7 2010.00 38 14.94 2893 1642 1.93 / 146.05 2 5
3 13 1970.60 18 14.91 2847 764 2.70 / 146.81 2 7
4 13 1184.04 18 15.02 1895 512 3.21 / 147.32 2 10
5 13 564.96 18 15.16 1096 299 3.51 / 147.62 2 10
6 13 118.60 18 15.26 482 132 3.64 / 147.75 2 8
7 8 0.04 165 15.25 303 762 4.40 / 148.52 2 12
Average= 4.24
(KJ/cycle)

Cycle 33 GMT 7/10/2023 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 41 15.20 445 277 0.28 / 140.11 2 3
2 7 2008.12 38 14.93 2895 1642 1.92 / 141.75 2 6
3 13 1676.80 18 14.95 2506 674 2.59 / 142.42 2 8
4 13 1153.04 18 15.02 1854 501 3.10 / 142.93 2 9
5 13 535.16 18 15.17 1052 287 3.38 / 143.21 2 9
6 13 138.72 18 15.26 511 140 3.52 / 143.35 2 8
7 8 0.04 165 15.26 302 760 4.28 / 144.11 2 15
Average= 4.24
(KJ/cycle)

Cycle 32 GMT 27/ 9/2023 14:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 41 15.22 437 273 0.27 / 135.76 2 2
2 7 2008.64 38 14.94 2888 1640 1.91 / 137.40 2 6
3 13 1754.20 18 14.94 2594 698 2.61 / 138.09 2 8
4 13 1205.24 18 15.02 1911 517 3.13 / 138.61 2 8
5 13 615.08 18 15.15 1162 317 3.44 / 138.93 2 9
6 13 153.16 18 15.25 530 145 3.59 / 139.07 2 9
7 8 0.20 165 15.25 301 757 4.35 / 139.83 2 14
Average= 4.24
(KJ/cycle)

Cycle 31 GMT 17/ 9/2023 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 41 15.20 445 277 0.28 / 131.39 2 3
2 7 2024.08 39 14.93 2907 1693 1.97 / 133.08 2 6
3 13 1763.84 18 14.95 2616 704 2.67 / 133.79 2 9
4 13 1172.44 18 15.00 1882 508 3.18 / 134.29 2 9
5 13 559.96 18 15.15 1090 297 3.48 / 134.59 2 10
6 13 104.64 18 15.29 465 128 3.61 / 134.72 2 8
7 8 0.04 165 15.26 304 765 4.37 / 135.48 2 16
Average= 4.23
(KJ/cycle)

Cycle 30 GMT 8/ 9/2023 0:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 40 15.21 445 271 0.27 / 126.89 2 3
2 7 2008.36 38 14.94 2900 1646 1.92 / 128.54 2 5
3 13 1795.12 18 14.95 2644 712 2.63 / 129.25 2 8
4 13 1240.64 18 15.02 1967 532 3.16 / 129.78 2 9
5 13 678.08 18 15.13 1246 339 3.50 / 130.12 2 10
6 13 114.64 18 15.28 478 131 3.63 / 130.25 2 8
7 13 35.56 18 15.28 363 100 3.73 / 130.35 2 7
8 8 -0.16 165 15.25 302 760 4.49 / 131.11 2 17
Average= 4.23
(KJ/cycle)

Cycle 29 GMT 29/ 8/2023 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 40 15.21 450 274 0.27 / 122.55 2 3
2 7 2018.80 38 14.94 2914 1654 1.93 / 124.21 2 6
3 13 1670.32 18 14.97 2500 674 2.60 / 124.88 2 7
4 13 1139.96 18 15.03 1840 498 3.10 / 125.38 2 10
5 13 646.84 18 15.14 1206 329 3.43 / 125.71 2 10
6 13 127.72 18 15.27 497 137 3.56 / 125.85 2 8
7 8 0.12 165 15.25 308 775 4.34 / 126.62 2 20
Average= 4.22
(KJ/cycle)

Cycle 28 GMT 19/ 8/2023 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 40 15.23 452 275 0.28 / 118.18 2 3
2 7 2021.60 38 14.94 2899 1646 1.92 / 119.83 2 6
3 13 1792.52 18 14.95 2635 709 2.63 / 120.54 2 7
4 13 1217.28 18 15.03 1928 522 3.15 / 121.06 2 9
5 13 570.56 18 15.17 1101 301 3.45 / 121.36 2 10
6 13 155.24 18 15.27 535 147 3.60 / 121.51 2 9
7 8 0.00 165 15.26 307 773 4.37 / 122.28 2 14
Average= 4.22
(KJ/cycle)

Cycle 27 GMT 9/ 8/2023 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 40 15.22 456 278 0.28 / 113.81 2 3
2 7 2009.96 39 14.96 2900 1692 1.97 / 115.51 2 7
3 13 1638.80 18 14.98 2462 664 2.63 / 116.17 2 8
4 13 1179.28 18 15.03 1888 511 3.14 / 116.68 2 8
5 13 666.72 18 15.15 1231 336 3.48 / 117.02 2 10
6 13 99.08 18 15.29 449 124 3.60 / 117.14 2 8
7 8 0.16 165 15.27 305 768 4.37 / 117.91 2 16
Average= 4.21
(KJ/cycle)

Cycle 26 GMT 30/ 7/2023 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 40 15.22 455 277 0.28 / 109.50 2 3
2 7 2010.72 38 14.94 2883 1637 1.91 / 111.14 2 6
3 13 1701.08 18 14.97 2527 681 2.59 / 111.82 2 7
4 13 1093.96 18 15.05 1784 483 3.08 / 112.30 2 10
5 13 604.12 18 15.15 1151 314 3.39 / 112.62 2 10
6 13 130.64 18 15.27 506 139 3.53 / 112.76 2 9
7 8 0.00 165 15.27 309 779 4.31 / 113.54 2 17
Average= 4.21
(KJ/cycle)

Cycle 25 GMT 21/ 7/2023 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 40 15.23 451 275 0.27 / 105.17 2 3
2 7 2025.08 38 14.95 2920 1659 1.93 / 106.83 2 5
3 13 1717.36 18 14.98 2550 688 2.62 / 107.52 2 8
4 13 1140.08 18 15.06 1841 499 3.12 / 108.01 2 11
5 13 533.16 18 15.19 1063 291 3.41 / 108.30 2 9
6 13 129.28 18 15.29 502 138 3.55 / 108.44 2 9
7 8 0.16 165 15.27 311 784 4.33 / 109.23 2 11
Average= 4.20
(KJ/cycle)

Cycle 24 GMT 11/ 7/2023 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 40 15.24 441 269 0.27 / 100.84 2 3
2 7 2010.68 38 14.98 2912 1658 1.93 / 102.50 2 7
3 13 1626.72 18 15.00 2449 661 2.59 / 103.16 2 10
4 13 1160.44 18 15.06 1869 507 3.09 / 103.67 2 9
5 13 585.28 18 15.18 1127 308 3.40 / 103.98 2 10
6 13 110.80 18 15.30 480 132 3.53 / 104.11 2 8
7 8 0.32 165 15.28 312 787 4.32 / 104.89 2 14
Average= 4.20
(KJ/cycle)

Cycle 23 GMT 1/ 7/2023 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 40 15.22 450 274 0.27 / 96.48 2 3
2 7 2023.56 38 14.97 2916 1659 1.93 / 98.14 2 7
3 13 1762.92 18 14.97 2605 702 2.63 / 98.84 2 7
4 13 1179.40 18 15.05 1892 513 3.15 / 99.36 2 11
5 13 634.04 18 15.15 1197 326 3.47 / 99.68 2 10
6 13 76.40 18 15.30 427 118 3.59 / 99.80 2 8
7 8 0.08 165 15.27 307 774 4.36 / 100.57 2 14
Average= 4.19
(KJ/cycle)

Cycle 22 GMT 21/ 6/2023 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 40 15.23 460 280 0.28 / 92.21 2 3
2 7 2008.08 38 14.96 2891 1643 1.92 / 93.85 2 5
3 13 1659.72 18 15.01 2488 672 2.60 / 94.52 2 9
4 13 1076.32 18 15.08 1766 479 3.08 / 95.00 2 9
5 13 594.24 18 15.17 1137 310 3.39 / 95.31 2 10
6 13 85.20 18 15.30 439 121 3.51 / 95.43 2 8
7 8 0.12 165 15.28 308 777 4.28 / 96.21 2 15
Average= 4.18
(KJ/cycle)

Cycle 21 GMT 12/ 6/2023 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 40 15.24 444 271 0.27 / 87.90 2 3
2 7 2010.20 38 14.97 2897 1648 1.92 / 89.55 2 6
3 13 1698.36 18 15.00 2533 684 2.60 / 90.23 2 8
4 13 1157.24 18 15.07 1866 506 3.11 / 90.74 2 9
5 13 528.72 18 15.21 1052 288 3.40 / 91.03 2 10
6 13 81.28 18 15.30 433 119 3.52 / 91.15 2 8
7 8 0.16 165 15.28 308 777 4.29 / 91.92 2 16
Average= 4.18
(KJ/cycle)

Cycle 20 GMT 2/ 6/2023 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 40 15.24 438 267 0.27 / 83.50 2 3
2 7 2007.68 39 14.97 2897 1691 1.96 / 85.19 2 5
3 13 1739.84 18 14.98 2584 697 2.66 / 85.88 2 9
4 13 1185.52 18 15.06 1899 515 3.17 / 86.40 2 10
5 13 625.88 18 15.17 1180 322 3.49 / 86.72 2 10
6 13 143.84 18 15.28 517 142 3.63 / 86.86 2 9
7 8 0.16 165 15.28 305 769 4.40 / 87.63 2 13
Average= 4.17
(KJ/cycle)

Cycle 19 GMT 23/ 5/2023 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 40 15.24 448 273 0.27 / 79.19 2 2
2 7 2008.68 38 14.97 2896 1647 1.92 / 80.84 2 5
3 13 1717.52 18 15.01 2553 690 2.61 / 81.53 2 7
4 13 1180.52 18 15.07 1894 514 3.12 / 82.04 2 9
5 13 527.56 18 15.21 1048 287 3.41 / 82.33 2 10
6 13 126.04 18 15.31 495 136 3.55 / 82.46 2 9
7 8 0.28 165 15.29 304 767 4.31 / 83.23 2 13
Average= 4.16
(KJ/cycle)

Cycle 18 GMT 13/ 5/2023 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 40 15.24 454 277 0.28 / 74.83 2 2
2 7 2006.88 38 14.98 2901 1651 1.93 / 76.49 2 5
3 13 1690.72 18 15.01 2530 684 2.61 / 77.17 2 7
4 13 1115.96 18 15.09 1808 491 3.10 / 77.66 2 9
5 13 506.56 18 15.21 1019 279 3.38 / 77.94 2 10
6 13 65.44 18 15.32 405 112 3.49 / 78.05 2 8
7 13 35.32 18 15.32 360 99 3.59 / 78.15 2 8
8 8 0.04 165 15.28 303 764 4.36 / 78.91 2 17
Average= 4.15
(KJ/cycle)

Cycle 17 GMT 3/ 5/2023 22:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 40 15.24 443 270 0.27 / 70.57 2 3
2 7 2008.92 38 14.99 2898 1651 1.92 / 72.22 2 5
3 13 1708.68 18 15.01 2549 689 2.61 / 72.91 2 7
4 13 1092.72 18 15.10 1783 485 3.09 / 73.39 2 9
5 13 521.08 18 15.21 1041 285 3.38 / 73.68 2 10
6 13 73.04 18 15.32 417 115 3.49 / 73.79 2 8
7 8 0.12 165 15.29 303 764 4.26 / 74.56 2 18
Average= 4.14
(KJ/cycle)

Cycle 16 GMT 24/ 4/2023 4:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 40 15.25 437 267 0.27 / 66.28 2 3
2 7 2009.80 38 15.00 2893 1649 1.92 / 67.93 2 5
3 13 1665.04 18 15.02 2487 672 2.59 / 68.60 2 7
4 13 1009.64 18 15.12 1671 455 3.04 / 69.06 2 10
5 13 465.80 18 15.23 960 263 3.31 / 69.32 2 10
6 13 107.64 18 15.31 464 128 3.43 / 69.45 2 9
7 13 27.64 18 15.32 349 96 3.53 / 69.54 2 9
8 8 0.04 165 15.29 300 757 4.29 / 70.30 2 17
Average= 4.14
(KJ/cycle)

Cycle 15 GMT 14/ 4/2023 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 40 15.25 441 269 0.27 / 61.92 2 2
2 7 2013.88 38 14.98 2900 1651 1.92 / 63.57 2 5
3 13 1676.48 18 15.01 2495 674 2.59 / 64.25 2 7
4 13 1145.12 18 15.08 1845 501 3.09 / 64.75 2 9
5 13 550.48 18 15.20 1075 294 3.39 / 65.04 2 11
6 13 78.36 18 15.32 424 117 3.51 / 65.16 2 9
7 13 21.04 18 15.33 340 94 3.60 / 65.25 2 9
8 8 -0.08 165 15.28 302 761 4.36 / 66.01 2 16
Average= 4.13
(KJ/cycle)

Cycle 14 GMT 4/ 4/2023 14:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 39 15.26 439 261 0.26 / 57.47 2 2
2 3 1017.56 1 15.29 1740 27 0.29 / 57.49 2 4
3 7 2007.36 38 15.00 2908 1658 1.95 / 59.15 2 5
4 13 1691.48 18 15.03 2525 683 2.63 / 59.83 2 7
5 13 1142.68 18 15.10 1848 502 3.13 / 60.34 2 8
6 13 594.12 18 15.20 1133 310 3.44 / 60.65 2 10
7 13 112.40 18 15.31 477 131 3.57 / 60.78 2 9
8 13 29.68 18 15.33 358 99 3.67 / 60.88 2 9
9 8 0.12 165 15.30 307 775 4.45 / 61.65 2 15
Average= 4.11
(KJ/cycle)

Cycle 13 GMT 25/ 3/2023 20:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 39 15.27 436 260 0.26 / 53.07 2 3
2 7 2024.08 38 15.00 2919 1664 1.92 / 54.73 2 5
3 13 1707.28 18 15.02 2541 687 2.61 / 55.42 2 7
4 13 1165.36 18 15.09 1876 510 3.12 / 55.93 2 8
5 13 526.40 18 15.22 1039 285 3.40 / 56.21 2 10
6 13 110.20 18 15.32 473 130 3.54 / 56.34 2 9
7 13 26.52 18 15.33 351 97 3.63 / 56.44 2 9
8 8 -0.12 165 15.31 303 765 4.40 / 57.21 2 17
Average= 4.09
(KJ/cycle)

Cycle 12 GMT 16/ 3/2023 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 40 15.27 433 264 0.26 / 48.79 2 3
2 7 2024.84 38 15.00 2921 1665 1.93 / 50.45 2 5
3 13 1673.36 18 15.02 2502 676 2.61 / 51.13 2 7
4 13 1165.12 18 15.09 1867 507 3.11 / 51.64 2 9
5 13 554.04 18 15.21 1077 295 3.41 / 51.93 2 10
6 13 89.36 18 15.33 439 121 3.53 / 52.05 2 9
7 8 0.08 165 15.31 299 755 4.28 / 52.81 2 14
Average= 4.06
(KJ/cycle)

Cycle 11 GMT 6/ 3/2023 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 40 15.22 438 267 0.27 / 44.58 2 3
2 7 2010.64 38 15.00 2901 1654 1.92 / 46.24 2 5
3 13 1608.52 18 15.04 2432 658 2.58 / 46.89 2 7
4 13 1064.20 18 15.11 1744 474 3.05 / 47.37 2 9
5 13 529.92 18 15.22 1047 287 3.34 / 47.65 2 10
6 13 65.08 18 15.33 403 111 3.45 / 47.77 2 8
7 8 0.12 165 15.31 300 758 4.21 / 48.52 2 19
Average= 4.04
(KJ/cycle)

Cycle 10 GMT 24/ 2/2023 12:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 39 15.27 459 273 0.27 / 38.51 2 3
2 3 1018.44 1 15.31 1755 27 0.30 / 38.53 2 4
3 7 2006.76 38 15.01 2903 1656 1.96 / 40.19 2 5
4 13 1669.16 18 15.04 2506 678 2.63 / 40.87 2 7
5 13 1300.16 18 15.06 2042 554 3.19 / 41.42 2 9
6 13 1290.76 18 15.02 2035 550 3.74 / 41.97 2 9
7 13 1267.56 18 14.98 1998 539 4.28 / 42.51 2 10
8 13 1233.08 18 14.96 1955 526 4.80 / 43.04 2 10
9 13 1156.40 18 14.94 1850 498 5.30 / 43.54 2 11
10 8 -0.08 165 15.25 310 780 6.08 / 44.32 2 21
Average= 4.03
(KJ/cycle)

Cycle 9 GMT 14/ 2/2023 18:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 39 15.26 436 259 0.26 / 34.20 2 3
2 7 2023.56 38 14.99 2916 1661 1.92 / 35.86 2 5
3 13 1715.72 18 15.03 2556 692 2.61 / 36.55 2 7
4 13 1129.28 18 15.10 1832 498 3.11 / 37.05 2 9
5 13 536.28 18 15.23 1057 290 3.40 / 37.34 2 10
6 13 118.96 18 15.33 481 133 3.53 / 37.47 2 9
7 8 0.16 165 15.32 303 766 4.30 / 38.23 2 16
Average= 3.82
(KJ/cycle)

Cycle 8 GMT 4/ 2/2023 23:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 39 15.27 440 262 0.26 / 29.93 2 3
2 3 1025.32 1 15.32 1755 27 0.29 / 29.95 2 5
3 7 2006.88 38 15.02 2893 1651 1.94 / 31.60 2 5
4 13 1611.40 18 15.06 2436 660 2.60 / 32.27 2 7
5 13 1104.08 18 15.12 1790 487 3.09 / 32.75 2 9
6 13 570.36 18 15.22 1098 301 3.39 / 33.05 2 10
7 13 105.40 18 15.34 460 127 3.52 / 33.18 2 9
8 8 0.08 165 15.32 299 756 4.27 / 33.94 2 15
Average= 3.77
(KJ/cycle)

Cycle 7 GMT 26/ 1/2023 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 37 15.26 434 245 0.25 / 25.14 2 3
2 10 1035.88 2 15.28 1740 53 0.30 / 25.20 2 4
3 7 2020.60 74 14.91 2901 3201 3.50 / 28.40 2 7
4 13 803.16 18 15.19 1405 384 3.88 / 28.78 2 11
5 13 123.36 18 15.34 479 132 4.02 / 28.91 2 10
6 8 0.16 165 15.34 297 752 4.77 / 29.66 2 15
Average= 3.71
(KJ/cycle)

Cycle 6 GMT 16/ 1/2023 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 15.29 433 185 0.19 / 20.08 2 2
2 10 1099.52 5 15.24 1816 138 0.32 / 20.22 2 3
3 10 1148.08 3 15.22 1886 86 0.41 / 20.30 2 3
4 3 1119.24 3 15.26 1876 86 0.50 / 20.39 2 5
5 7 2021.96 74 14.92 2904 3206 3.70 / 23.60 2 6
6 13 787.56 18 15.18 1390 380 4.08 / 23.98 2 10
7 13 182.88 18 15.32 571 157 4.24 / 24.13 2 10
8 8 0.00 165 15.32 302 763 5.00 / 24.90 2 15
Average= 3.56
(KJ/cycle)

Cycle 5 GMT 6/ 1/2023 11:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 15.31 447 198 0.20 / 15.48 2 3
2 3 965.84 -1 15.62 0 0 0.00 / 15.48 2 3
3 7 2010.96 75 14.90 2888 3227 3.43 / 18.70 2 5
4 13 620.44 18 15.23 1162 319 3.74 / 19.02 2 9
5 13 103.00 18 15.34 446 123 3.87 / 19.15 2 7
6 8 0.08 165 15.32 296 748 4.62 / 19.89 2 19
Average= 3.32
(KJ/cycle)

Cycle 4 GMT 27/12/2022 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 27 15.29 448 185 0.18 / 11.84 2 2
2 3 1026.28 1 15.34 1756 27 0.21 / 11.86 2 4
3 7 1511.08 74 15.07 2266 2527 2.74 / 14.39 2 5
4 13 151.28 18 15.36 517 143 2.88 / 14.53 2 8
5 8 0.12 165 15.35 295 747 3.63 / 15.28 2 13
Average= 3.06
(KJ/cycle)

Cycle 3 GMT 26/12/2022 14:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 25 15.31 443 170 0.17 / 8.14 2 2
2 10 1054.80 3 15.28 1755 80 0.25 / 8.22 2 3
3 7 1524.68 74 15.05 2282 2541 2.79 / 10.76 2 5
4 13 147.04 18 15.36 513 142 2.93 / 10.90 2 7
5 8 0.00 165 15.34 296 749 3.68 / 11.65 2 15
Average= 2.91
(KJ/cycle)

Cycle 2 GMT 25/12/2022 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 15.34 446 212 0.21 / 4.58 2 2
2 3 823.52 -3 15.62 0 0 0.00 / 4.58 2 2
3 3 918.36 -2 15.65 0 0 0.00 / 4.58 2 2
4 7 1509.84 74 15.08 2257 2519 2.73 / 7.09 2 5
5 13 137.44 18 15.36 495 137 2.87 / 7.23 2 7
6 8 0.12 165 15.35 291 737 3.60 / 7.97 2 12
Average= 2.66
(KJ/cycle)

Cycle 1 GMT 24/12/2022 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 26 15.52 414 167 0.17 / 1.79 2 2
2 7 1001.44 74 15.23 1616 1821 1.99 / 3.61 2 7
3 8 -0.12 165 15.39 296 752 2.74 / 4.36 2 14
Average= 2.18
(KJ/cycle)

Cycle 0 GMT 24/12/2022 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 130.24 26 15.68 443 181 0.18 / 0.18 2 2
2 7 143.64 74 15.64 444 514 0.69 / 0.69 2 3
3 8 0.36 240 15.60 248 929 1.62 / 1.62 2 10
Average= 1.62
(KJ/cycle)