SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.44 | 30 | 15.13 | 477 | 217 | 0.22 / 349.16 | 2 | 3 |
2 | 7 | 2010.36 | 74 | 14.62 | 2992 | 3237 | 3.45 / 352.40 | 2 | 6 |
3 | 13 | 555.84 | 18 | 15.10 | 1132 | 308 | 3.76 / 352.71 | 2 | 10 |
4 | 13 | 151.28 | 18 | 15.21 | 551 | 151 | 3.91 / 352.86 | 2 | 9 |
5 | 8 | 0.88 | 165 | 15.19 | 314 | 787 | 4.70 / 353.65 | 2 | 13 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 30 | 15.12 | 474 | 215 | 0.22 / 344.47 | 2 | 3 |
2 | 7 | 2003.48 | 74 | 14.62 | 2975 | 3219 | 3.43 / 347.69 | 2 | 6 |
3 | 13 | 645.00 | 18 | 15.08 | 1250 | 339 | 3.77 / 348.03 | 2 | 10 |
4 | 13 | 112.60 | 18 | 15.23 | 491 | 135 | 3.91 / 348.16 | 2 | 11 |
5 | 8 | 0.32 | 165 | 15.19 | 314 | 787 | 4.69 / 348.95 | 2 | 20 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 30 | 15.13 | 472 | 214 | 0.21 / 339.76 | 2 | 3 |
2 | 7 | 2006.56 | 75 | 14.62 | 2983 | 3271 | 3.49 / 343.04 | 2 | 7 |
3 | 13 | 553.44 | 18 | 15.10 | 1134 | 308 | 3.79 / 343.34 | 2 | 10 |
4 | 13 | 94.16 | 18 | 15.23 | 463 | 127 | 3.92 / 343.47 | 2 | 8 |
5 | 8 | -0.20 | 165 | 15.19 | 312 | 782 | 4.70 / 344.25 | 2 | 16 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 30 | 15.13 | 476 | 216 | 0.22 / 335.11 | 2 | 3 |
2 | 7 | 2005.96 | 74 | 14.63 | 2984 | 3231 | 3.45 / 338.34 | 2 | 6 |
3 | 13 | 538.92 | 18 | 15.12 | 1104 | 300 | 3.75 / 338.64 | 2 | 10 |
4 | 13 | 88.12 | 18 | 15.24 | 450 | 123 | 3.87 / 338.77 | 2 | 10 |
5 | 8 | -0.12 | 165 | 15.20 | 312 | 782 | 4.65 / 339.55 | 2 | 10 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 30 | 15.14 | 447 | 203 | 0.20 / 330.37 | 2 | 3 |
2 | 7 | 2007.12 | 74 | 14.62 | 2987 | 3232 | 3.43 / 333.60 | 2 | 8 |
3 | 13 | 633.76 | 18 | 15.07 | 1247 | 338 | 3.77 / 333.94 | 2 | 10 |
4 | 13 | 151.68 | 18 | 15.22 | 563 | 154 | 3.93 / 334.09 | 2 | 10 |
5 | 8 | -0.08 | 165 | 15.19 | 320 | 802 | 4.73 / 334.90 | 2 | 19 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.36 | 30 | 15.12 | 473 | 215 | 0.21 / 325.74 | 2 | 3 |
2 | 7 | 2009.84 | 74 | 14.63 | 2995 | 3242 | 3.46 / 328.98 | 2 | 5 |
3 | 13 | 460.08 | 18 | 15.15 | 1001 | 273 | 3.73 / 329.26 | 2 | 9 |
4 | 13 | 84.20 | 18 | 15.23 | 449 | 123 | 3.85 / 329.38 | 2 | 10 |
5 | 8 | 0.12 | 165 | 15.21 | 314 | 788 | 4.64 / 330.17 | 2 | 18 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 30 | 15.14 | 469 | 213 | 0.21 / 321.03 | 2 | 3 |
2 | 7 | 2011.24 | 74 | 14.62 | 2990 | 3235 | 3.45 / 324.26 | 2 | 6 |
3 | 13 | 640.84 | 18 | 15.08 | 1247 | 338 | 3.79 / 324.60 | 2 | 11 |
4 | 13 | 111.00 | 18 | 15.22 | 494 | 135 | 3.92 / 324.73 | 2 | 10 |
5 | 8 | 0.20 | 165 | 15.19 | 316 | 792 | 4.71 / 325.53 | 2 | 18 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 30 | 15.13 | 475 | 216 | 0.22 / 316.33 | 2 | 3 |
2 | 7 | 2010.76 | 74 | 14.63 | 2992 | 3239 | 3.45 / 319.57 | 2 | 7 |
3 | 13 | 585.56 | 18 | 15.11 | 1174 | 319 | 3.77 / 319.89 | 2 | 11 |
4 | 13 | 75.60 | 18 | 15.23 | 446 | 122 | 3.90 / 320.01 | 2 | 7 |
5 | 8 | -0.20 | 165 | 15.19 | 321 | 805 | 4.70 / 320.81 | 2 | 20 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 30 | 15.15 | 480 | 218 | 0.22 / 311.57 | 2 | 3 |
2 | 7 | 2014.88 | 74 | 14.64 | 2998 | 3248 | 3.47 / 314.81 | 2 | 7 |
3 | 13 | 707.08 | 18 | 15.07 | 1341 | 364 | 3.83 / 315.18 | 2 | 11 |
4 | 13 | 109.88 | 18 | 15.24 | 496 | 136 | 3.97 / 315.31 | 2 | 10 |
5 | 8 | -0.44 | 165 | 15.20 | 318 | 798 | 4.76 / 316.11 | 2 | 20 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 15.15 | 478 | 217 | 0.22 / 306.91 | 2 | 3 |
2 | 7 | 2004.68 | 74 | 14.65 | 2986 | 3237 | 3.45 / 310.15 | 2 | 7 |
3 | 13 | 456.44 | 18 | 15.17 | 995 | 272 | 3.73 / 310.42 | 2 | 10 |
4 | 13 | 81.04 | 18 | 15.25 | 455 | 125 | 3.85 / 310.54 | 2 | 8 |
5 | 8 | 0.16 | 165 | 15.21 | 321 | 806 | 4.66 / 311.35 | 2 | 10 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 30 | 15.15 | 473 | 215 | 0.21 / 302.18 | 2 | 3 |
2 | 7 | 2010.48 | 74 | 14.65 | 2993 | 3245 | 3.46 / 305.42 | 2 | 8 |
3 | 13 | 664.76 | 18 | 15.09 | 1282 | 348 | 3.81 / 305.77 | 2 | 11 |
4 | 13 | 83.00 | 18 | 15.25 | 451 | 124 | 3.93 / 305.90 | 2 | 7 |
5 | 8 | 0.12 | 165 | 15.21 | 317 | 796 | 4.73 / 306.69 | 2 | 12 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 30 | 15.14 | 460 | 209 | 0.21 / 297.50 | 2 | 3 |
2 | 7 | 2014.12 | 74 | 14.63 | 3000 | 3248 | 3.46 / 300.75 | 2 | 7 |
3 | 13 | 510.84 | 18 | 15.15 | 1075 | 293 | 3.75 / 301.05 | 2 | 10 |
4 | 13 | 65.36 | 18 | 15.25 | 424 | 116 | 3.87 / 301.16 | 2 | 11 |
5 | 8 | 0.32 | 165 | 15.21 | 320 | 803 | 4.67 / 301.96 | 2 | 15 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 30 | 15.17 | 471 | 214 | 0.21 / 292.76 | 2 | 3 |
2 | 7 | 2003.24 | 74 | 14.64 | 2982 | 3231 | 3.44 / 295.99 | 2 | 7 |
3 | 13 | 646.72 | 18 | 15.11 | 1260 | 343 | 3.79 / 296.34 | 2 | 10 |
4 | 13 | 117.20 | 18 | 15.25 | 510 | 140 | 3.93 / 296.48 | 2 | 9 |
5 | 8 | 0.16 | 165 | 15.22 | 326 | 819 | 4.75 / 297.30 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 30 | 15.16 | 474 | 216 | 0.22 / 287.93 | 2 | 3 |
2 | 10 | 1000.72 | 2 | 15.19 | 1774 | 54 | 0.27 / 287.98 | 2 | 4 |
3 | 3 | 947.44 | -2 | 15.55 | 1 | 0 | 0.05 / 287.98 | 2 | 4 |
4 | 3 | 1017.92 | 1 | 15.25 | 1818 | 28 | 0.30 / 288.01 | 2 | 6 |
5 | 7 | 2011.60 | 75 | 14.64 | 3006 | 3301 | 3.60 / 291.31 | 2 | 7 |
6 | 13 | 585.44 | 18 | 15.13 | 1172 | 319 | 3.92 / 291.63 | 2 | 9 |
7 | 13 | 67.40 | 18 | 15.26 | 431 | 118 | 4.04 / 291.75 | 2 | 11 |
8 | 8 | 0.04 | 165 | 15.22 | 319 | 801 | 4.84 / 292.55 | 2 | 14 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 30 | 15.17 | 466 | 212 | 0.21 / 283.23 | 2 | 3 |
2 | 7 | 2005.88 | 74 | 14.64 | 2988 | 3237 | 3.45 / 286.47 | 2 | 7 |
3 | 13 | 548.04 | 18 | 15.14 | 1125 | 307 | 3.76 / 286.77 | 2 | 10 |
4 | 13 | 141.80 | 18 | 15.25 | 545 | 150 | 3.91 / 286.92 | 2 | 9 |
5 | 8 | 0.40 | 165 | 15.22 | 315 | 791 | 4.70 / 287.71 | 2 | 11 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 30 | 15.16 | 459 | 209 | 0.21 / 278.56 | 2 | 3 |
2 | 7 | 2003.32 | 74 | 14.65 | 2982 | 3233 | 3.44 / 281.80 | 2 | 7 |
3 | 13 | 538.72 | 18 | 15.15 | 1110 | 303 | 3.74 / 282.10 | 2 | 10 |
4 | 13 | 83.68 | 18 | 15.27 | 452 | 124 | 3.87 / 282.22 | 2 | 10 |
5 | 8 | -0.28 | 165 | 15.23 | 316 | 794 | 4.66 / 283.02 | 2 | 14 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 30 | 15.18 | 466 | 212 | 0.21 / 273.85 | 2 | 3 |
2 | 7 | 2010.40 | 74 | 14.65 | 2997 | 3249 | 3.46 / 277.10 | 2 | 7 |
3 | 13 | 603.16 | 18 | 15.13 | 1202 | 327 | 3.79 / 277.43 | 2 | 10 |
4 | 13 | 79.84 | 18 | 15.27 | 449 | 123 | 3.91 / 277.55 | 2 | 9 |
5 | 8 | -0.28 | 165 | 15.22 | 320 | 804 | 4.72 / 278.35 | 2 | 21 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.16 | 443 | 201 | 0.20 / 269.17 | 2 | 3 |
2 | 7 | 2009.60 | 75 | 14.66 | 2993 | 3291 | 3.49 / 272.46 | 2 | 6 |
3 | 13 | 486.72 | 18 | 15.16 | 1042 | 284 | 3.78 / 272.74 | 2 | 9 |
4 | 13 | 61.32 | 18 | 15.27 | 413 | 114 | 3.89 / 272.86 | 2 | 7 |
5 | 8 | -0.12 | 165 | 15.23 | 311 | 782 | 4.67 / 273.64 | 2 | 16 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 30 | 15.17 | 467 | 213 | 0.21 / 264.50 | 2 | 3 |
2 | 7 | 2004.80 | 74 | 14.66 | 2986 | 3239 | 3.45 / 267.73 | 2 | 7 |
3 | 13 | 575.24 | 18 | 15.14 | 1164 | 317 | 3.77 / 268.05 | 2 | 10 |
4 | 13 | 113.44 | 18 | 15.27 | 494 | 136 | 3.90 / 268.19 | 2 | 10 |
5 | 8 | -0.20 | 165 | 15.23 | 310 | 779 | 4.68 / 268.97 | 2 | 9 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 30 | 15.17 | 449 | 204 | 0.20 / 259.81 | 2 | 3 |
2 | 7 | 2010.12 | 74 | 14.65 | 2991 | 3243 | 3.45 / 263.05 | 2 | 7 |
3 | 13 | 589.60 | 18 | 15.14 | 1181 | 322 | 3.77 / 263.38 | 2 | 10 |
4 | 13 | 80.72 | 18 | 15.27 | 443 | 122 | 3.89 / 263.50 | 2 | 8 |
5 | 8 | -0.04 | 165 | 15.24 | 312 | 785 | 4.68 / 264.28 | 2 | 13 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 30 | 15.16 | 440 | 200 | 0.20 / 255.18 | 2 | 3 |
2 | 7 | 2011.00 | 74 | 14.66 | 2994 | 3248 | 3.45 / 258.43 | 2 | 6 |
3 | 13 | 456.40 | 18 | 15.19 | 995 | 272 | 3.72 / 258.70 | 2 | 10 |
4 | 13 | 85.40 | 18 | 15.27 | 452 | 124 | 3.84 / 258.82 | 2 | 7 |
5 | 8 | 0.08 | 165 | 15.23 | 312 | 784 | 4.63 / 259.61 | 2 | 11 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 30 | 15.18 | 452 | 206 | 0.21 / 250.47 | 2 | 3 |
2 | 7 | 2003.40 | 75 | 14.66 | 2982 | 3279 | 3.48 / 253.75 | 2 | 6 |
3 | 13 | 534.68 | 18 | 15.17 | 1104 | 301 | 3.79 / 254.05 | 2 | 10 |
4 | 13 | 116.12 | 18 | 15.27 | 499 | 137 | 3.92 / 254.19 | 2 | 10 |
5 | 8 | -0.24 | 165 | 15.24 | 314 | 790 | 4.71 / 254.98 | 2 | 11 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 15.18 | 443 | 202 | 0.20 / 245.81 | 2 | 3 |
2 | 7 | 2009.56 | 74 | 14.66 | 2994 | 3248 | 3.45 / 249.06 | 2 | 7 |
3 | 13 | 507.24 | 18 | 15.18 | 1066 | 291 | 3.74 / 249.35 | 2 | 10 |
4 | 13 | 69.20 | 18 | 15.28 | 429 | 118 | 3.86 / 249.47 | 2 | 10 |
5 | 8 | 0.44 | 165 | 15.24 | 316 | 795 | 4.65 / 250.27 | 2 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 30 | 15.19 | 440 | 201 | 0.20 / 241.12 | 2 | 3 |
2 | 7 | 2010.52 | 75 | 14.65 | 2996 | 3292 | 3.49 / 244.41 | 2 | 8 |
3 | 13 | 505.64 | 18 | 15.17 | 1065 | 291 | 3.78 / 244.70 | 2 | 10 |
4 | 13 | 70.40 | 18 | 15.27 | 433 | 119 | 3.90 / 244.82 | 2 | 11 |
5 | 8 | -0.16 | 165 | 15.23 | 316 | 794 | 4.70 / 245.61 | 2 | 9 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 30 | 15.19 | 469 | 214 | 0.21 / 236.46 | 2 | 3 |
2 | 7 | 2004.24 | 74 | 14.67 | 2986 | 3242 | 3.46 / 239.71 | 2 | 6 |
3 | 13 | 523.08 | 18 | 15.18 | 1094 | 299 | 3.75 / 240.01 | 2 | 10 |
4 | 13 | 78.08 | 18 | 15.28 | 442 | 122 | 3.88 / 240.13 | 2 | 8 |
5 | 8 | 0.04 | 165 | 15.24 | 314 | 790 | 4.67 / 240.92 | 2 | 17 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 30 | 15.17 | 470 | 214 | 0.21 / 231.76 | 2 | 3 |
2 | 7 | 2009.80 | 74 | 14.67 | 3005 | 3262 | 3.48 / 235.02 | 2 | 5 |
3 | 13 | 507.56 | 18 | 15.19 | 1077 | 294 | 3.77 / 235.32 | 2 | 10 |
4 | 13 | 109.56 | 18 | 15.29 | 493 | 136 | 3.91 / 235.45 | 2 | 10 |
5 | 8 | -0.12 | 165 | 15.25 | 318 | 800 | 4.71 / 236.25 | 2 | 20 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 30 | 15.17 | 477 | 217 | 0.22 / 227.04 | 2 | 3 |
2 | 7 | 2009.36 | 74 | 14.67 | 2998 | 3255 | 3.47 / 230.29 | 2 | 7 |
3 | 13 | 536.84 | 18 | 15.17 | 1112 | 304 | 3.78 / 230.60 | 2 | 10 |
4 | 13 | 137.84 | 18 | 15.28 | 539 | 148 | 3.92 / 230.74 | 2 | 11 |
5 | 8 | 0.32 | 165 | 15.25 | 318 | 800 | 4.72 / 231.54 | 2 | 4 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 30 | 15.19 | 471 | 215 | 0.21 / 222.31 | 2 | 3 |
2 | 7 | 2003.32 | 75 | 14.67 | 2993 | 3293 | 3.51 / 225.61 | 2 | 8 |
3 | 13 | 475.08 | 18 | 15.19 | 1032 | 282 | 3.79 / 225.89 | 2 | 10 |
4 | 13 | 84.04 | 18 | 15.29 | 457 | 126 | 3.92 / 226.02 | 2 | 9 |
5 | 8 | -0.28 | 165 | 15.25 | 320 | 805 | 4.72 / 226.82 | 2 | 15 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.19 | 475 | 216 | 0.22 / 217.66 | 2 | 3 |
2 | 7 | 2010.00 | 74 | 14.67 | 3006 | 3263 | 3.48 / 220.92 | 2 | 7 |
3 | 13 | 423.00 | 18 | 15.21 | 959 | 263 | 3.74 / 221.18 | 2 | 9 |
4 | 13 | 58.92 | 18 | 15.30 | 419 | 115 | 3.86 / 221.30 | 2 | 7 |
5 | 8 | 0.00 | 165 | 15.25 | 318 | 800 | 4.66 / 222.10 | 2 | 15 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 30 | 15.19 | 469 | 214 | 0.21 / 212.97 | 2 | 3 |
2 | 7 | 2008.16 | 74 | 14.67 | 3000 | 3257 | 3.47 / 216.23 | 2 | 8 |
3 | 13 | 504.28 | 18 | 15.18 | 1068 | 292 | 3.76 / 216.52 | 2 | 10 |
4 | 13 | 67.24 | 18 | 15.29 | 429 | 118 | 3.88 / 216.64 | 2 | 9 |
5 | 8 | 0.20 | 165 | 15.25 | 320 | 805 | 4.69 / 217.44 | 2 | 13 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.19 | 477 | 217 | 0.22 / 208.29 | 2 | 3 |
2 | 7 | 2005.80 | 74 | 14.69 | 2995 | 3256 | 3.47 / 211.55 | 2 | 7 |
3 | 13 | 481.64 | 18 | 15.20 | 1044 | 286 | 3.76 / 211.83 | 2 | 10 |
4 | 13 | 88.48 | 18 | 15.30 | 464 | 128 | 3.89 / 211.96 | 2 | 9 |
5 | 8 | 0.16 | 165 | 15.26 | 316 | 796 | 4.68 / 212.76 | 2 | 14 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 30 | 15.19 | 459 | 209 | 0.21 / 203.59 | 2 | 3 |
2 | 7 | 2009.20 | 74 | 14.69 | 2995 | 3256 | 3.46 / 206.84 | 2 | 7 |
3 | 13 | 495.76 | 18 | 15.20 | 1056 | 289 | 3.75 / 207.13 | 2 | 11 |
4 | 13 | 96.04 | 18 | 15.30 | 477 | 131 | 3.89 / 207.26 | 2 | 10 |
5 | 8 | -0.32 | 165 | 15.26 | 322 | 811 | 4.70 / 208.07 | 2 | 20 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 30 | 15.20 | 482 | 220 | 0.22 / 198.90 | 2 | 3 |
2 | 7 | 2010.92 | 74 | 14.68 | 3010 | 3270 | 3.49 / 202.17 | 2 | 7 |
3 | 13 | 505.60 | 18 | 15.19 | 1065 | 291 | 3.78 / 202.46 | 2 | 11 |
4 | 13 | 74.32 | 18 | 15.29 | 440 | 121 | 3.90 / 202.58 | 2 | 8 |
5 | 8 | -0.08 | 165 | 15.25 | 317 | 798 | 4.70 / 203.38 | 2 | 16 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 30 | 15.21 | 473 | 216 | 0.22 / 194.19 | 2 | 3 |
2 | 7 | 2004.56 | 74 | 14.69 | 2997 | 3258 | 3.47 / 197.45 | 2 | 7 |
3 | 13 | 497.56 | 18 | 15.21 | 1058 | 290 | 3.76 / 197.74 | 2 | 10 |
4 | 13 | 103.64 | 18 | 15.30 | 488 | 134 | 3.90 / 197.88 | 2 | 10 |
5 | 8 | -0.16 | 165 | 15.27 | 319 | 804 | 4.70 / 198.68 | 2 | 15 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 15.21 | 476 | 217 | 0.22 / 189.45 | 2 | 3 |
2 | 7 | 2011.48 | 75 | 14.69 | 3011 | 3317 | 3.53 / 192.77 | 2 | 7 |
3 | 13 | 469.92 | 18 | 15.23 | 1022 | 280 | 3.81 / 193.05 | 2 | 10 |
4 | 13 | 76.92 | 18 | 15.31 | 444 | 122 | 3.94 / 193.17 | 2 | 8 |
5 | 8 | -0.04 | 165 | 15.27 | 320 | 806 | 4.74 / 193.98 | 2 | 18 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 30 | 15.21 | 488 | 223 | 0.22 / 184.70 | 2 | 3 |
2 | 7 | 2004.92 | 75 | 14.71 | 3004 | 3314 | 3.54 / 188.02 | 2 | 8 |
3 | 13 | 512.24 | 18 | 15.21 | 1082 | 296 | 3.83 / 188.31 | 2 | 10 |
4 | 13 | 61.84 | 18 | 15.32 | 421 | 116 | 3.95 / 188.43 | 2 | 9 |
5 | 8 | 0.28 | 165 | 15.28 | 320 | 807 | 4.76 / 189.23 | 2 | 12 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 30 | 15.22 | 476 | 217 | 0.22 / 179.94 | 2 | 3 |
2 | 7 | 2007.20 | 75 | 14.69 | 3007 | 3313 | 3.53 / 183.25 | 2 | 8 |
3 | 13 | 511.00 | 18 | 15.21 | 1087 | 298 | 3.83 / 183.55 | 2 | 10 |
4 | 13 | 62.00 | 18 | 15.32 | 428 | 118 | 3.95 / 183.67 | 2 | 9 |
5 | 8 | 0.04 | 165 | 15.27 | 322 | 811 | 4.76 / 184.48 | 2 | 14 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 30 | 15.22 | 477 | 218 | 0.22 / 175.20 | 2 | 3 |
2 | 7 | 2007.80 | 75 | 14.70 | 3005 | 3313 | 3.53 / 178.51 | 2 | 8 |
3 | 13 | 509.80 | 18 | 15.21 | 1077 | 295 | 3.83 / 178.81 | 2 | 10 |
4 | 13 | 58.16 | 18 | 15.32 | 414 | 114 | 3.94 / 178.92 | 2 | 9 |
5 | 8 | -0.04 | 165 | 15.27 | 317 | 799 | 4.74 / 179.72 | 2 | 15 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.21 | 479 | 219 | 0.22 / 170.49 | 2 | 3 |
2 | 7 | 2005.72 | 74 | 14.69 | 3002 | 3263 | 3.48 / 173.76 | 2 | 8 |
3 | 13 | 532.36 | 18 | 15.20 | 1113 | 305 | 3.79 / 174.06 | 2 | 10 |
4 | 13 | 41.64 | 18 | 15.32 | 393 | 108 | 3.89 / 174.17 | 2 | 8 |
5 | 8 | 0.04 | 165 | 15.27 | 323 | 814 | 4.71 / 174.98 | 2 | 12 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 30 | 15.22 | 453 | 207 | 0.21 / 165.77 | 2 | 3 |
2 | 7 | 2009.04 | 74 | 14.71 | 3004 | 3270 | 3.48 / 169.04 | 2 | 7 |
3 | 13 | 530.04 | 18 | 15.20 | 1107 | 303 | 3.78 / 169.35 | 2 | 10 |
4 | 13 | 68.76 | 18 | 15.31 | 432 | 119 | 3.90 / 169.47 | 2 | 8 |
5 | 8 | -0.36 | 165 | 15.27 | 321 | 809 | 4.71 / 170.27 | 2 | 13 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.40 | 30 | 15.22 | 483 | 221 | 0.22 / 161.08 | 2 | 3 |
2 | 7 | 2004.04 | 74 | 14.71 | 3002 | 3268 | 3.49 / 164.34 | 2 | 7 |
3 | 13 | 546.88 | 18 | 15.20 | 1124 | 308 | 3.80 / 164.65 | 2 | 10 |
4 | 13 | 56.40 | 18 | 15.31 | 410 | 113 | 3.91 / 164.77 | 2 | 8 |
5 | 8 | -0.12 | 165 | 15.27 | 318 | 801 | 4.71 / 165.57 | 2 | 9 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 30 | 15.23 | 476 | 217 | 0.22 / 156.32 | 2 | 3 |
2 | 7 | 2009.96 | 74 | 14.71 | 3003 | 3269 | 3.49 / 159.59 | 2 | 7 |
3 | 13 | 479.96 | 18 | 15.23 | 1039 | 285 | 3.77 / 159.87 | 2 | 9 |
4 | 13 | 188.72 | 18 | 15.31 | 617 | 170 | 3.94 / 160.04 | 2 | 9 |
5 | 8 | 0.28 | 165 | 15.28 | 323 | 814 | 4.76 / 160.86 | 2 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.23 | 478 | 218 | 0.22 / 151.64 | 2 | 3 |
2 | 7 | 2006.32 | 74 | 14.71 | 3000 | 3266 | 3.48 / 154.91 | 2 | 7 |
3 | 13 | 426.88 | 18 | 15.25 | 959 | 263 | 3.75 / 155.17 | 2 | 10 |
4 | 13 | 52.84 | 18 | 15.34 | 409 | 113 | 3.86 / 155.29 | 2 | 7 |
5 | 8 | 0.16 | 165 | 15.29 | 323 | 815 | 4.68 / 156.10 | 2 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 15.23 | 450 | 206 | 0.21 / 146.98 | 2 | 3 |
2 | 7 | 2009.28 | 74 | 14.70 | 3000 | 3263 | 3.47 / 150.25 | 2 | 7 |
3 | 13 | 443.88 | 18 | 15.24 | 981 | 269 | 3.74 / 150.52 | 2 | 9 |
4 | 13 | 58.60 | 18 | 15.32 | 412 | 114 | 3.85 / 150.63 | 2 | 7 |
5 | 8 | 0.12 | 165 | 15.29 | 315 | 795 | 4.65 / 151.43 | 2 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 30 | 15.24 | 486 | 222 | 0.22 / 142.25 | 2 | 3 |
2 | 7 | 2011.72 | 74 | 14.71 | 3015 | 3282 | 3.50 / 145.53 | 2 | 8 |
3 | 13 | 514.28 | 18 | 15.22 | 1082 | 296 | 3.80 / 145.83 | 2 | 10 |
4 | 13 | 105.44 | 18 | 15.33 | 492 | 136 | 3.94 / 145.97 | 2 | 10 |
5 | 8 | 0.04 | 165 | 15.29 | 322 | 812 | 4.75 / 146.78 | 2 | 12 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 30 | 15.23 | 474 | 217 | 0.22 / 137.52 | 2 | 3 |
2 | 7 | 2008.72 | 74 | 14.71 | 3004 | 3270 | 3.49 / 140.79 | 2 | 9 |
3 | 13 | 528.92 | 18 | 15.22 | 1100 | 301 | 3.79 / 141.09 | 2 | 11 |
4 | 13 | 62.24 | 18 | 15.33 | 427 | 118 | 3.91 / 141.21 | 2 | 7 |
5 | 8 | -0.24 | 165 | 15.29 | 327 | 825 | 4.73 / 142.03 | 2 | 18 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 29 | 15.23 | 482 | 213 | 0.21 / 132.78 | 2 | 3 |
2 | 7 | 2007.96 | 74 | 14.72 | 3009 | 3278 | 3.49 / 136.05 | 2 | 7 |
3 | 13 | 565.64 | 18 | 15.22 | 1153 | 316 | 3.81 / 136.37 | 2 | 10 |
4 | 13 | 82.88 | 18 | 15.34 | 452 | 125 | 3.93 / 136.49 | 2 | 9 |
5 | 8 | 0.12 | 165 | 15.30 | 319 | 805 | 4.74 / 137.30 | 2 | 22 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 29 | 15.25 | 462 | 204 | 0.20 / 128.14 | 2 | 3 |
2 | 7 | 2003.28 | 74 | 14.73 | 3000 | 3270 | 3.47 / 131.41 | 2 | 7 |
3 | 13 | 372.12 | 18 | 15.29 | 882 | 243 | 3.72 / 131.65 | 2 | 10 |
4 | 13 | 53.32 | 18 | 15.35 | 407 | 112 | 3.83 / 131.76 | 2 | 9 |
5 | 8 | 0.60 | 165 | 15.30 | 317 | 800 | 4.63 / 132.56 | 2 | 17 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 29 | 15.24 | 482 | 213 | 0.21 / 123.47 | 2 | 3 |
2 | 7 | 2002.96 | 74 | 14.73 | 2996 | 3266 | 3.48 / 126.74 | 2 | 7 |
3 | 13 | 467.84 | 18 | 15.25 | 1012 | 278 | 3.76 / 127.02 | 2 | 10 |
4 | 13 | 42.64 | 18 | 15.34 | 385 | 106 | 3.86 / 127.12 | 2 | 5 |
5 | 8 | 0.20 | 165 | 15.30 | 321 | 810 | 4.67 / 127.93 | 2 | 12 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 29 | 15.25 | 476 | 211 | 0.21 / 118.75 | 2 | 3 |
2 | 7 | 2012.20 | 74 | 14.73 | 3006 | 3277 | 3.49 / 122.03 | 2 | 6 |
3 | 13 | 514.64 | 18 | 15.23 | 1078 | 296 | 3.78 / 122.32 | 2 | 10 |
4 | 13 | 105.76 | 18 | 15.34 | 485 | 134 | 3.92 / 122.46 | 2 | 9 |
5 | 8 | 0.12 | 165 | 15.30 | 318 | 803 | 4.72 / 123.26 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 29 | 15.23 | 460 | 203 | 0.20 / 114.07 | 2 | 3 |
2 | 7 | 2003.64 | 74 | 14.74 | 3000 | 3272 | 3.48 / 117.34 | 2 | 9 |
3 | 13 | 469.20 | 18 | 15.25 | 1017 | 279 | 3.75 / 117.62 | 2 | 10 |
4 | 13 | 69.92 | 18 | 15.34 | 434 | 120 | 3.87 / 117.74 | 2 | 8 |
5 | 8 | -0.32 | 165 | 15.30 | 316 | 798 | 4.67 / 118.54 | 2 | 12 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 29 | 15.23 | 471 | 208 | 0.21 / 109.40 | 2 | 3 |
2 | 7 | 2011.12 | 74 | 14.72 | 3003 | 3271 | 3.48 / 112.67 | 2 | 6 |
3 | 13 | 464.28 | 18 | 15.25 | 1007 | 276 | 3.76 / 112.95 | 2 | 10 |
4 | 13 | 69.16 | 18 | 15.33 | 431 | 119 | 3.87 / 113.07 | 2 | 8 |
5 | 8 | 0.20 | 165 | 15.29 | 317 | 800 | 4.67 / 113.87 | 2 | 12 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 15.24 | 457 | 202 | 0.20 / 104.62 | 2 | 3 |
2 | 7 | 2011.16 | 74 | 14.73 | 3003 | 3273 | 3.48 / 107.90 | 2 | 7 |
3 | 13 | 490.88 | 18 | 15.24 | 1047 | 287 | 3.76 / 108.18 | 2 | 10 |
4 | 13 | 62.84 | 18 | 15.35 | 423 | 117 | 3.88 / 108.30 | 2 | 8 |
5 | 13 | 19.40 | 18 | 15.34 | 353 | 97 | 3.98 / 108.40 | 2 | 7 |
6 | 8 | -0.12 | 165 | 15.29 | 316 | 797 | 4.77 / 109.19 | 2 | 11 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 29 | 15.25 | 477 | 211 | 0.21 / 99.94 | 2 | 3 |
2 | 7 | 2004.04 | 74 | 14.73 | 2999 | 3269 | 3.48 / 103.20 | 2 | 8 |
3 | 13 | 513.12 | 18 | 15.23 | 1082 | 297 | 3.78 / 103.50 | 2 | 10 |
4 | 13 | 66.08 | 18 | 15.34 | 423 | 117 | 3.89 / 103.62 | 2 | 9 |
5 | 8 | 0.20 | 165 | 15.29 | 318 | 802 | 4.70 / 104.42 | 2 | 19 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 29 | 15.25 | 482 | 213 | 0.21 / 95.25 | 2 | 3 |
2 | 7 | 2003.28 | 74 | 14.74 | 3000 | 3272 | 3.49 / 98.53 | 2 | 7 |
3 | 13 | 453.40 | 18 | 15.26 | 993 | 273 | 3.76 / 98.80 | 2 | 9 |
4 | 13 | 57.80 | 18 | 15.35 | 418 | 115 | 3.87 / 98.91 | 2 | 9 |
5 | 8 | 0.24 | 165 | 15.31 | 321 | 811 | 4.68 / 99.72 | 2 | 12 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 29 | 15.24 | 453 | 200 | 0.20 / 90.59 | 2 | 3 |
2 | 7 | 2007.36 | 74 | 14.73 | 3006 | 3277 | 3.48 / 93.86 | 2 | 7 |
3 | 13 | 381.48 | 18 | 15.28 | 898 | 247 | 3.72 / 94.11 | 2 | 10 |
4 | 13 | 54.56 | 18 | 15.35 | 413 | 114 | 3.84 / 94.22 | 2 | 10 |
5 | 8 | 0.12 | 165 | 15.30 | 323 | 815 | 4.65 / 95.04 | 2 | 8 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 29 | 15.24 | 467 | 206 | 0.21 / 85.90 | 2 | 3 |
2 | 7 | 2011.80 | 74 | 14.74 | 3013 | 3286 | 3.49 / 89.18 | 2 | 7 |
3 | 13 | 456.40 | 18 | 15.27 | 1003 | 276 | 3.77 / 89.46 | 2 | 10 |
4 | 13 | 60.24 | 18 | 15.35 | 422 | 117 | 3.89 / 89.58 | 2 | 8 |
5 | 8 | 0.12 | 165 | 15.30 | 321 | 810 | 4.70 / 90.39 | 2 | 13 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 29 | 15.25 | 481 | 213 | 0.21 / 81.24 | 2 | 3 |
2 | 7 | 2011.72 | 74 | 14.74 | 3005 | 3278 | 3.49 / 84.51 | 2 | 7 |
3 | 13 | 415.12 | 18 | 15.27 | 943 | 259 | 3.75 / 84.77 | 2 | 10 |
4 | 13 | 48.52 | 18 | 15.35 | 398 | 110 | 3.86 / 84.88 | 2 | 7 |
5 | 8 | 0.24 | 165 | 15.30 | 320 | 808 | 4.67 / 85.69 | 2 | 8 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 29 | 15.24 | 458 | 202 | 0.20 / 76.53 | 2 | 3 |
2 | 7 | 2009.36 | 74 | 14.76 | 3006 | 3283 | 3.49 / 79.81 | 2 | 8 |
3 | 13 | 457.44 | 18 | 15.27 | 1008 | 277 | 3.76 / 80.09 | 2 | 10 |
4 | 13 | 56.84 | 18 | 15.36 | 416 | 115 | 3.88 / 80.20 | 2 | 7 |
5 | 8 | 0.28 | 165 | 15.31 | 325 | 821 | 4.70 / 81.02 | 2 | 12 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 29 | 15.26 | 472 | 209 | 0.21 / 71.87 | 2 | 3 |
2 | 7 | 2007.60 | 74 | 14.76 | 3003 | 3280 | 3.49 / 75.15 | 2 | 7 |
3 | 13 | 387.04 | 18 | 15.30 | 906 | 250 | 3.74 / 75.40 | 2 | 9 |
4 | 13 | 37.96 | 18 | 15.37 | 386 | 107 | 3.85 / 75.51 | 2 | 9 |
5 | 8 | 0.16 | 165 | 15.32 | 324 | 819 | 4.66 / 76.33 | 2 | 24 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 29 | 15.26 | 467 | 207 | 0.21 / 67.15 | 2 | 3 |
2 | 7 | 2011.60 | 74 | 14.76 | 3008 | 3285 | 3.49 / 70.44 | 2 | 9 |
3 | 13 | 496.80 | 18 | 15.26 | 1058 | 291 | 3.78 / 70.73 | 2 | 10 |
4 | 13 | 47.04 | 18 | 15.37 | 403 | 111 | 3.89 / 70.84 | 2 | 8 |
5 | 8 | -0.24 | 165 | 15.32 | 324 | 819 | 4.71 / 71.66 | 2 | 9 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 29 | 15.26 | 466 | 206 | 0.21 / 62.47 | 2 | 3 |
2 | 7 | 2008.96 | 74 | 14.77 | 3004 | 3283 | 3.49 / 65.76 | 2 | 8 |
3 | 13 | 476.60 | 18 | 15.28 | 1030 | 283 | 3.77 / 66.04 | 2 | 9 |
4 | 13 | 38.20 | 18 | 15.38 | 385 | 107 | 3.88 / 66.15 | 2 | 9 |
5 | 8 | -0.16 | 165 | 15.34 | 317 | 802 | 4.68 / 66.95 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 29 | 15.25 | 463 | 205 | 0.20 / 57.79 | 2 | 3 |
2 | 7 | 2004.08 | 75 | 14.77 | 2995 | 3318 | 3.52 / 61.11 | 2 | 7 |
3 | 13 | 410.44 | 18 | 15.30 | 935 | 257 | 3.78 / 61.36 | 2 | 10 |
4 | 13 | 44.48 | 18 | 15.38 | 388 | 107 | 3.89 / 61.47 | 2 | 8 |
5 | 8 | 0.08 | 165 | 15.33 | 314 | 794 | 4.68 / 62.27 | 2 | 13 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 29 | 15.26 | 464 | 205 | 0.21 / 53.11 | 2 | 3 |
2 | 7 | 2008.08 | 74 | 14.77 | 2997 | 3276 | 3.48 / 56.38 | 2 | 8 |
3 | 13 | 494.88 | 18 | 15.27 | 1054 | 290 | 3.77 / 56.67 | 2 | 9 |
4 | 13 | 52.96 | 18 | 15.37 | 405 | 112 | 3.88 / 56.78 | 2 | 7 |
5 | 8 | 0.00 | 165 | 15.32 | 317 | 801 | 4.68 / 57.58 | 2 | 14 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.27 | 464 | 205 | 0.21 / 48.42 | 2 | 3 |
2 | 7 | 2004.24 | 74 | 14.78 | 2992 | 3272 | 3.48 / 51.69 | 2 | 6 |
3 | 13 | 507.84 | 18 | 15.26 | 1078 | 296 | 3.77 / 51.99 | 2 | 10 |
4 | 13 | 50.68 | 18 | 15.37 | 401 | 111 | 3.88 / 52.10 | 2 | 8 |
5 | 8 | 0.08 | 165 | 15.33 | 317 | 802 | 4.69 / 52.90 | 2 | 13 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 29 | 15.25 | 465 | 206 | 0.21 / 43.74 | 2 | 3 |
2 | 7 | 2004.44 | 74 | 14.78 | 2990 | 3270 | 3.48 / 47.01 | 2 | 8 |
3 | 13 | 424.56 | 18 | 15.30 | 954 | 263 | 3.74 / 47.27 | 2 | 10 |
4 | 13 | 132.52 | 18 | 15.37 | 526 | 146 | 3.88 / 47.41 | 2 | 9 |
5 | 8 | 0.60 | 165 | 15.34 | 316 | 800 | 4.68 / 48.21 | 2 | 12 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 29 | 15.29 | 471 | 209 | 0.21 / 39.02 | 2 | 3 |
2 | 7 | 2009.60 | 75 | 14.79 | 3000 | 3328 | 3.54 / 42.35 | 2 | 5 |
3 | 13 | 436.92 | 18 | 15.30 | 979 | 270 | 3.81 / 42.62 | 2 | 10 |
4 | 13 | 45.40 | 18 | 15.38 | 392 | 109 | 3.91 / 42.72 | 2 | 7 |
5 | 8 | 0.04 | 165 | 15.34 | 318 | 805 | 4.72 / 43.53 | 2 | 14 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 29 | 15.28 | 466 | 206 | 0.21 / 34.36 | 2 | 3 |
2 | 7 | 2009.16 | 74 | 14.79 | 2995 | 3278 | 3.48 / 37.64 | 2 | 6 |
3 | 13 | 430.92 | 18 | 15.31 | 959 | 264 | 3.75 / 37.91 | 2 | 9 |
4 | 13 | 43.00 | 18 | 15.39 | 384 | 106 | 3.86 / 38.01 | 2 | 8 |
5 | 8 | 0.24 | 165 | 15.34 | 315 | 797 | 4.65 / 38.81 | 2 | 14 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 29 | 15.29 | 473 | 210 | 0.21 / 29.74 | 2 | 3 |
2 | 7 | 2005.92 | 74 | 14.79 | 2995 | 3278 | 3.49 / 33.02 | 2 | 6 |
3 | 13 | 353.52 | 18 | 15.34 | 850 | 235 | 3.72 / 33.26 | 2 | 9 |
4 | 13 | 39.84 | 18 | 15.40 | 378 | 105 | 3.83 / 33.36 | 2 | 7 |
5 | 8 | -0.04 | 165 | 15.35 | 314 | 795 | 4.62 / 34.16 | 2 | 15 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 28 | 15.30 | 465 | 199 | 0.20 / 25.08 | 2 | 3 |
2 | 7 | 2008.08 | 75 | 14.80 | 2998 | 3328 | 3.53 / 28.41 | 2 | 6 |
3 | 13 | 342.68 | 18 | 15.34 | 828 | 229 | 3.76 / 28.64 | 2 | 9 |
4 | 13 | 38.28 | 18 | 15.39 | 375 | 104 | 3.86 / 28.74 | 2 | 8 |
5 | 8 | -0.08 | 165 | 15.34 | 313 | 792 | 4.65 / 29.54 | 2 | 14 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 27 | 15.30 | 471 | 195 | 0.19 / 20.43 | 2 | 3 |
2 | 10 | 1000.56 | 2 | 15.31 | 1763 | 54 | 0.25 / 20.49 | 2 | 5 |
3 | 7 | 2003.36 | 74 | 14.81 | 2985 | 3271 | 3.52 / 23.76 | 2 | 5 |
4 | 13 | 377.72 | 18 | 15.34 | 873 | 241 | 3.76 / 24.00 | 2 | 9 |
5 | 13 | 27.88 | 18 | 15.40 | 356 | 99 | 3.86 / 24.10 | 2 | 7 |
6 | 8 | 0.08 | 165 | 15.36 | 310 | 786 | 4.65 / 24.88 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 29 | 15.30 | 455 | 202 | 0.20 / 15.84 | 2 | 3 |
2 | 3 | 933.88 | -1 | 15.72 | 1 | 0 | 0.00 / 15.84 | 2 | 3 |
3 | 7 | 2004.72 | 74 | 14.81 | 2986 | 3272 | 3.47 / 19.11 | 2 | 6 |
4 | 13 | 371.44 | 18 | 15.35 | 862 | 238 | 3.71 / 19.35 | 2 | 8 |
5 | 13 | 49.84 | 18 | 15.40 | 390 | 108 | 3.82 / 19.45 | 2 | 7 |
6 | 8 | -0.36 | 165 | 15.37 | 309 | 784 | 4.60 / 20.24 | 2 | 11 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 27 | 15.31 | 458 | 189 | 0.19 / 12.11 | 2 | 3 |
2 | 7 | 1509.28 | 74 | 15.01 | 2348 | 2608 | 2.80 / 14.72 | 2 | 6 |
3 | 13 | 151.04 | 18 | 15.40 | 538 | 149 | 2.95 / 14.87 | 2 | 7 |
4 | 8 | -0.32 | 165 | 15.37 | 302 | 766 | 3.71 / 15.63 | 2 | 12 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 25 | 15.31 | 446 | 171 | 0.17 / 8.32 | 2 | 3 |
2 | 10 | 1023.76 | 2 | 15.32 | 1784 | 55 | 0.23 / 8.38 | 2 | 4 |
3 | 7 | 1508.20 | 75 | 15.00 | 2348 | 2641 | 2.87 / 11.02 | 2 | 7 |
4 | 13 | 141.48 | 18 | 15.39 | 521 | 144 | 3.01 / 11.16 | 2 | 7 |
5 | 8 | 0.48 | 165 | 15.36 | 300 | 760 | 3.77 / 11.92 | 2 | 13 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 31 | 15.35 | 454 | 216 | 0.22 / 4.65 | 2 | 3 |
2 | 3 | 804.44 | -4 | 15.73 | 1 | 0 | 0.00 / 4.65 | 2 | 3 |
3 | 3 | 942.52 | -1 | 15.75 | 1 | 0 | 0.00 / 4.65 | 2 | 3 |
4 | 7 | 1507.60 | 74 | 15.01 | 2342 | 2601 | 2.82 / 7.25 | 2 | 6 |
5 | 13 | 141.48 | 18 | 15.41 | 512 | 142 | 2.96 / 7.39 | 2 | 7 |
6 | 8 | -0.16 | 165 | 15.37 | 299 | 758 | 3.72 / 8.15 | 2 | 10 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 26 | 15.51 | 400 | 161 | 0.16 / 1.81 | 2 | 3 |
2 | 7 | 990.08 | 74 | 15.20 | 1659 | 1866 | 2.03 / 3.68 | 2 | 8 |
3 | 8 | -0.04 | 165 | 15.41 | 297 | 755 | 2.78 / 4.43 | 2 | 14 |
Average= | 2.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 157.40 | 26 | 15.67 | 471 | 192 | 0.19 / 0.19 | 3 | 3 |
2 | 7 | 173.40 | 74 | 15.63 | 484 | 560 | 0.75 / 0.75 | 2 | 3 |
3 | 8 | 0.28 | 240 | 15.59 | 240 | 898 | 1.65 / 1.65 | 2 | 9 |
Average= | 1.65 (KJ/cycle) |