SIO Argo Site:
Pump Diagnostics Page   



Serial= 7886 WMO= 2903437

Return

←PreviousNext→

Cycle 39 GMT 16/ 4/2025 22:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 35 14.71 492 253 0.25 / 185.96 5 5
2 7 2008.88 41 14.30 3239 1899 2.15 / 187.86 5 8
3 13 1446.44 20 14.37 2444 702 2.85 / 188.57 5 13
4 13 900.28 20 14.49 1670 484 3.34 / 189.05 5 16
5 13 185.12 20 14.75 608 179 3.52 / 189.23 5 12
6 8 -0.08 289 14.75 332 1415 4.93 / 190.64 5 142
Average= 4.77
(KJ/cycle)

Cycle 38 GMT 6/ 4/2025 16: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 35 14.72 488 251 0.25 / 181.08 5 5
2 7 2003.44 40 14.30 3234 1850 2.10 / 182.93 5 8
3 13 1457.92 20 14.36 2476 711 2.81 / 183.64 5 13
4 13 883.24 20 14.49 1660 481 3.29 / 184.12 5 16
5 13 102.48 20 14.78 494 146 3.44 / 184.27 5 13
6 8 0.24 289 14.75 338 1441 4.88 / 185.71 5 139
Average= 4.76
(KJ/cycle)

Cycle 37 GMT 27/ 3/2025 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 35 14.73 499 257 0.26 / 176.18 5 5
2 7 2008.72 41 14.30 3239 1899 2.16 / 178.08 5 8
3 13 1429.52 20 14.37 2424 697 2.85 / 178.77 5 12
4 13 858.60 20 14.50 1610 467 3.32 / 179.24 5 15
5 13 139.80 20 14.75 551 163 3.48 / 179.40 5 12
6 8 -0.04 289 14.74 335 1427 4.91 / 180.83 5 151
Average= 4.76
(KJ/cycle)

Cycle 36 GMT 17/ 3/2025 3:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 35 14.74 485 250 0.25 / 171.21 5 5
2 7 2017.68 40 14.32 3256 1865 2.12 / 173.07 5 7
3 13 1658.12 20 14.35 2737 786 2.90 / 173.86 5 11
4 13 862.36 20 14.53 1610 468 3.37 / 174.33 5 14
5 13 163.36 20 14.77 580 171 3.54 / 174.50 5 9
6 8 0.32 291 14.77 331 1423 4.96 / 175.92 5 155
Average= 4.75
(KJ/cycle)

Cycle 35 GMT 6/ 3/2025 21:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 35 14.74 484 250 0.25 / 166.30 5 5
2 7 2011.12 40 14.32 3248 1860 2.11 / 168.16 5 7
3 13 1456.48 20 14.39 2455 707 2.82 / 168.87 5 10
4 13 989.28 20 14.48 1802 522 3.34 / 169.39 5 14
5 13 168.48 20 14.78 574 170 3.51 / 169.56 5 9
6 8 0.16 291 14.77 326 1401 4.91 / 170.96 5 168
Average= 4.75
(KJ/cycle)

Cycle 34 GMT 24/ 2/2025 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 35 14.73 498 257 0.26 / 161.34 5 5
2 7 2016.36 40 14.32 3228 1849 2.11 / 163.19 6 7
3 13 1549.80 20 14.37 2574 740 2.85 / 163.93 5 11
4 13 955.16 20 14.49 1750 507 3.35 / 164.43 5 15
5 13 235.60 20 14.74 692 204 3.56 / 164.64 5 11
6 8 0.24 289 14.77 331 1413 4.97 / 166.05 5 136
Average= 4.74
(KJ/cycle)

Cycle 33 GMT 14/ 2/2025 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 34 14.76 484 243 0.24 / 156.27 5 5
2 7 2006.56 40 14.32 3242 1857 2.10 / 158.12 5 7
3 13 1560.28 20 14.36 2618 752 2.85 / 158.88 5 11
4 13 971.40 20 14.48 1784 517 3.37 / 159.39 5 14
5 13 344.68 20 14.70 847 249 3.62 / 159.64 5 12
6 8 0.12 291 14.76 335 1439 5.06 / 161.08 5 157
Average= 4.74
(KJ/cycle)

Cycle 32 GMT 4/ 2/2025 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 34 14.75 498 250 0.25 / 151.34 5 5
2 7 2012.04 40 14.35 3218 1847 2.10 / 153.19 5 8
3 13 1427.96 20 14.40 2445 704 2.80 / 153.89 5 12
4 13 973.96 20 14.50 1788 519 3.32 / 154.41 5 13
5 13 151.76 20 14.80 566 168 3.49 / 154.58 5 9
6 8 0.04 289 14.78 339 1448 4.94 / 156.02 5 137
Average= 4.73
(KJ/cycle)

Cycle 31 GMT 24/ 1/2025 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 34 14.78 491 247 0.25 / 146.31 5 5
2 3 1025.44 1 14.77 1801 27 0.27 / 146.34 5 9
3 7 2011.64 41 14.32 3259 1913 2.19 / 148.25 9 7
4 13 1443.96 20 14.39 2459 708 2.89 / 148.96 5 11
5 13 880.76 20 14.52 1650 479 3.37 / 149.44 5 15
6 13 177.12 20 14.78 607 179 3.55 / 149.61 5 10
7 8 0.24 289 14.78 345 1474 5.03 / 151.09 5 155
Average= 4.72
(KJ/cycle)

Cycle 30 GMT 14/ 1/2025 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 33 14.74 517 251 0.25 / 141.34 5 5
2 3 1021.20 1 14.73 1839 27 0.28 / 141.36 5 8
3 7 2014.16 40 14.33 3250 1863 2.14 / 143.23 8 8
4 13 1441.36 20 14.41 2442 704 2.85 / 143.93 5 12
5 13 972.84 20 14.51 1772 514 3.36 / 144.44 5 15
6 13 152.52 20 14.81 564 167 3.53 / 144.61 5 10
7 8 0.12 289 14.80 339 1450 4.98 / 146.06 5 143
Average= 4.71
(KJ/cycle)

Cycle 29 GMT 4/ 1/2025 7:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 34 14.72 501 251 0.25 / 136.29 5 5
2 3 945.28 -1 15.20 0 0 0.00 / 136.29 5 5
3 7 2007.12 41 14.31 3252 1908 2.16 / 138.20 5 8
4 13 1356.44 20 14.43 2343 676 2.83 / 138.87 5 14
5 13 1015.96 20 14.48 1851 536 3.37 / 139.41 5 16
6 13 174.52 20 14.78 614 181 3.55 / 139.59 5 14
7 8 0.08 289 14.78 350 1495 5.05 / 141.09 5 139
Average= 4.70
(KJ/cycle)

Cycle 28 GMT 25/12/2024 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 34 14.77 512 257 0.26 / 131.27 5 5
2 3 1026.84 1 14.76 1811 27 0.28 / 131.29 5 8
3 7 2008.52 40 14.31 3274 1874 2.16 / 133.17 8 9
4 13 1517.36 20 14.38 2566 738 2.90 / 133.91 5 12
5 13 809.52 20 14.54 1555 452 3.35 / 134.36 5 17
6 13 111.68 20 14.79 524 155 3.50 / 134.51 5 16
7 8 0.08 291 14.76 355 1525 5.03 / 136.04 5 140
Average= 4.69
(KJ/cycle)

Cycle 27 GMT 14/12/2024 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 33 14.77 499 243 0.24 / 126.34 5 5
2 7 2014.04 40 14.34 3264 1872 2.12 / 128.21 5 8
3 13 1442.28 20 14.42 2444 705 2.82 / 128.91 5 12
4 13 805.52 20 14.58 1536 448 3.27 / 129.36 5 15
5 13 206.12 20 14.79 652 193 3.46 / 129.55 5 11
6 8 0.12 287 14.80 343 1457 4.92 / 131.01 5 139
Average= 4.68
(KJ/cycle)

Cycle 26 GMT 4/12/2024 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 32 14.76 491 232 0.23 / 121.31 5 5
2 10 1043.48 3 14.67 1856 82 0.31 / 121.39 5 8
3 3 959.96 -1 15.21 0 0 0.08 / 121.39 5 8
4 7 2003.76 41 14.33 3208 1885 2.20 / 123.27 8 8
5 13 1445.12 20 14.42 2446 705 2.90 / 123.98 5 13
6 13 875.48 20 14.55 1645 479 3.38 / 124.46 5 16
7 13 154.32 20 14.80 574 170 3.55 / 124.63 5 13
8 8 -0.04 287 14.79 345 1464 5.02 / 126.09 5 140
Average= 4.67
(KJ/cycle)

Cycle 25 GMT 24/11/2024 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 32 14.75 512 242 0.24 / 116.38 5 5
2 7 2004.96 40 14.34 3240 1858 2.10 / 118.23 5 8
3 13 1325.08 20 14.46 2280 659 2.76 / 118.89 5 14
4 13 880.88 20 14.55 1649 480 3.24 / 119.37 5 16
5 13 288.28 20 14.75 782 231 3.47 / 119.60 5 16
6 8 0.04 289 14.79 344 1470 4.94 / 121.08 5 137
Average= 4.66
(KJ/cycle)

Cycle 24 GMT 14/11/2024 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.75 506 239 0.24 / 111.49 5 5
2 7 2004.08 40 14.33 3243 1859 2.10 / 113.34 5 8
3 13 1427.96 20 14.43 2448 706 2.80 / 114.05 5 13
4 13 746.76 20 14.59 1460 426 3.23 / 114.48 5 18
5 13 77.48 20 14.82 476 141 3.37 / 114.62 5 17
6 8 0.28 289 14.78 355 1516 4.89 / 116.13 5 137
Average= 4.65
(KJ/cycle)

Cycle 23 GMT 3/11/2024 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 32 14.75 503 237 0.24 / 106.55 5 5
2 7 2011.84 40 14.33 3252 1864 2.10 / 108.41 5 9
3 13 1337.84 20 14.45 2306 666 2.77 / 109.08 5 14
4 13 878.36 20 14.55 1641 478 3.25 / 109.56 5 18
5 13 160.24 20 14.79 594 176 3.42 / 109.73 5 19
6 8 0.00 291 14.78 352 1514 4.94 / 111.25 5 142
Average= 4.64
(KJ/cycle)

Cycle 22 GMT 24/10/2024 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 32 14.75 498 235 0.24 / 101.63 5 5
2 7 2008.48 40 14.33 3248 1862 2.10 / 103.50 5 9
3 13 1423.80 20 14.43 2426 700 2.80 / 104.20 5 13
4 13 812.12 20 14.58 1547 451 3.25 / 104.65 5 18
5 13 100.52 20 14.82 508 151 3.40 / 104.80 5 18
6 8 0.12 291 14.79 352 1515 4.91 / 106.31 5 147
Average= 4.62
(KJ/cycle)

Cycle 21 GMT 14/10/2024 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 32 14.76 503 238 0.24 / 96.68 5 5
2 7 2008.64 40 14.34 3246 1862 2.10 / 98.54 5 8
3 13 1429.88 20 14.44 2419 699 2.80 / 99.24 5 13
4 13 846.84 20 14.56 1604 467 3.27 / 99.71 5 18
5 13 148.56 20 14.80 580 172 3.44 / 99.88 5 19
6 8 -0.12 293 14.79 350 1517 4.95 / 101.40 5 146
Average= 4.61
(KJ/cycle)

Cycle 20 GMT 3/10/2024 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 14.75 524 247 0.25 / 91.75 5 6
2 7 2003.68 40 14.35 3225 1851 2.10 / 93.60 6 8
3 13 1516.24 20 14.43 2543 734 2.83 / 94.33 5 13
4 13 794.24 20 14.59 1519 443 3.28 / 94.78 5 18
5 13 105.60 20 14.83 511 152 3.43 / 94.93 5 17
6 8 0.16 291 14.80 352 1516 4.94 / 96.44 5 142
Average= 4.59
(KJ/cycle)

Cycle 19 GMT 23/ 9/2024 16:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 33 14.76 510 248 0.25 / 86.78 5 5
2 3 966.32 -1 15.23 0 0 0.00 / 86.78 5 5
3 7 2011.44 40 14.35 3225 1851 2.10 / 88.63 5 9
4 13 1334.08 20 14.47 2287 662 2.76 / 89.30 5 13
5 13 874.92 20 14.56 1644 479 3.24 / 89.77 5 18
6 13 154.20 20 14.80 594 176 3.42 / 89.95 5 18
7 8 0.04 293 14.79 358 1551 4.97 / 91.50 5 157
Average= 4.58
(KJ/cycle)

Cycle 18 GMT 13/ 9/2024 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 33 14.78 499 243 0.24 / 81.86 5 5
2 7 2013.84 40 14.35 3228 1853 2.10 / 83.72 5 8
3 13 1427.60 20 14.45 2417 699 2.79 / 84.41 5 14
4 13 860.56 20 14.57 1620 472 3.27 / 84.89 5 17
5 13 81.48 20 14.84 474 141 3.41 / 85.03 5 16
6 8 0.08 291 14.80 350 1507 4.91 / 86.53 5 151
Average= 4.55
(KJ/cycle)

Cycle 17 GMT 3/ 9/2024 3:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 34 14.79 490 246 0.25 / 76.88 5 5
2 7 2003.12 40 14.36 3240 1861 2.11 / 78.74 5 8
3 13 1530.40 20 14.43 2575 743 2.85 / 79.48 5 13
4 13 938.52 20 14.56 1727 503 3.35 / 79.99 5 16
5 13 113.52 20 14.85 516 153 3.51 / 80.14 5 14
6 8 -0.04 291 14.82 343 1479 4.99 / 81.62 5 157
Average= 4.53
(KJ/cycle)

Cycle 16 GMT 23/ 8/2024 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 33 14.81 497 243 0.24 / 71.91 5 5
2 3 1028.16 1 14.79 1824 27 0.27 / 71.94 5 9
3 7 2007.68 40 14.36 3232 1856 2.13 / 73.80 9 8
4 13 1434.92 20 14.46 2441 706 2.83 / 74.50 5 13
5 13 968.56 20 14.55 1773 516 3.35 / 75.02 5 17
6 13 118.88 20 14.85 520 154 3.50 / 75.17 5 12
7 8 0.36 289 14.83 341 1461 4.96 / 76.63 5 140
Average= 4.51
(KJ/cycle)

Cycle 15 GMT 13/ 8/2024 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 33 14.79 501 245 0.24 / 66.97 5 5
2 7 2011.76 40 14.37 3239 1862 2.11 / 68.83 5 8
3 13 1439.96 20 14.47 2453 710 2.82 / 69.54 5 12
4 13 862.64 20 14.60 1627 475 3.29 / 70.02 5 15
5 13 234.68 20 14.81 700 207 3.50 / 70.22 5 13
6 8 0.04 289 14.84 337 1445 4.94 / 71.67 5 156
Average= 4.48
(KJ/cycle)

Cycle 14 GMT 3/ 8/2024 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 34 14.80 497 250 0.25 / 62.00 5 5
2 7 2012.84 40 14.36 3264 1875 2.12 / 63.87 5 8
3 13 1534.36 20 14.44 2569 742 2.87 / 64.61 5 12
4 13 832.52 20 14.60 1578 461 3.33 / 65.07 5 16
5 13 138.84 20 14.84 554 164 3.49 / 65.24 5 14
6 8 0.04 289 14.82 347 1486 4.98 / 66.73 5 131
Average= 4.45
(KJ/cycle)

Cycle 13 GMT 24/ 7/2024 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 33 14.82 486 238 0.24 / 56.98 5 5
2 3 1038.64 1 14.79 1870 28 0.27 / 57.00 5 8
3 7 2009.80 40 14.37 3267 1878 2.14 / 58.88 8 7
4 13 1431.56 20 14.47 2447 708 2.85 / 59.59 5 14
5 13 859.28 20 14.60 1615 472 3.32 / 60.06 5 17
6 13 252.24 20 14.80 726 215 3.54 / 60.28 5 14
7 8 0.12 289 14.83 343 1470 5.01 / 61.75 5 141
Average= 4.41
(KJ/cycle)

Cycle 12 GMT 13/ 7/2024 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 14.79 512 242 0.24 / 51.99 5 5
2 7 2004.64 40 14.39 3244 1867 2.11 / 53.85 6 7
3 13 1449.12 20 14.47 2471 715 2.82 / 54.57 5 11
4 13 991.48 20 14.56 1817 529 3.35 / 55.10 5 16
5 13 173.84 20 14.85 601 178 3.53 / 55.28 5 11
6 8 0.24 289 14.85 341 1463 5.00 / 56.74 5 142
Average= 4.36
(KJ/cycle)

Cycle 11 GMT 3/ 7/2024 13:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 32 14.79 523 248 0.25 / 47.03 5 5
2 7 2009.88 40 14.37 3269 1879 2.13 / 48.91 5 8
3 13 1420.56 20 14.48 2416 700 2.83 / 49.61 5 13
4 13 850.20 20 14.60 1604 468 3.29 / 50.08 5 18
5 13 141.44 20 14.84 564 167 3.46 / 50.25 5 16
6 8 -0.24 291 14.83 347 1497 4.96 / 51.74 5 154
Average= 4.31
(KJ/cycle)

Cycle 10 GMT 23/ 6/2024 7:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.79 499 236 0.24 / 42.13 5 5
2 7 2010.96 40 14.38 3242 1865 2.10 / 44.00 5 9
3 13 1326.40 20 14.50 2287 663 2.76 / 44.66 5 14
4 13 782.88 20 14.62 1510 442 3.21 / 45.10 5 17
5 13 202.24 20 14.81 659 195 3.40 / 45.30 5 18
6 8 0.24 289 14.83 347 1487 4.89 / 46.78 5 137
Average= 4.25
(KJ/cycle)

Cycle 9 GMT 13/ 6/2024 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 14.79 511 242 0.24 / 37.28 5 5
2 7 2004.84 40 14.38 3253 1871 2.11 / 39.15 5 8
3 13 1320.60 20 14.51 2287 664 2.78 / 39.81 5 14
4 13 765.68 20 14.63 1492 437 3.21 / 40.25 5 17
5 13 75.16 20 14.87 474 141 3.35 / 40.39 5 18
6 8 -0.24 289 14.83 351 1504 4.86 / 41.90 5 137
Average= 4.19
(KJ/cycle)

Cycle 8 GMT 2/ 6/2024 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 32 14.78 516 244 0.24 / 32.36 5 5
2 7 2004.00 41 14.38 3250 1916 2.16 / 34.28 5 8
3 13 1325.60 20 14.51 2288 664 2.82 / 34.94 5 12
4 13 759.36 20 14.63 1484 434 3.26 / 35.38 5 18
5 13 86.60 20 14.86 489 145 3.40 / 35.52 5 18
6 8 0.16 289 14.83 353 1513 4.92 / 37.04 5 132
Average= 4.12
(KJ/cycle)

Cycle 7 GMT 23/ 5/2024 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 14.80 497 228 0.23 / 27.48 5 5
2 3 1036.44 1 14.76 1876 28 0.26 / 27.51 5 10
3 7 2013.52 40 14.38 3254 1872 2.13 / 29.38 10 8
4 13 1339.28 20 14.50 2306 669 2.80 / 30.05 5 14
5 13 691.60 20 14.65 1373 402 3.20 / 30.45 5 18
6 13 71.28 20 14.87 472 140 3.34 / 30.59 5 18
7 8 0.04 291 14.82 355 1531 4.87 / 32.12 5 140
Average= 4.02
(KJ/cycle)

Cycle 6 GMT 13/ 5/2024 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 14.79 502 230 0.23 / 22.54 5 5
2 10 1008.00 3 14.69 1831 81 0.31 / 22.63 5 10
3 3 948.80 -1 15.25 0 0 0.08 / 22.63 5 10
4 7 2004.52 40 14.40 3224 1857 2.17 / 24.48 10 8
5 13 1335.28 20 14.51 2301 668 2.84 / 25.15 5 13
6 13 758.04 20 14.64 1480 433 3.27 / 25.58 5 18
7 13 84.24 20 14.87 484 144 3.41 / 25.73 5 17
8 8 0.12 291 14.83 353 1523 4.94 / 27.25 5 153
Average= 3.89
(KJ/cycle)

Cycle 5 GMT 2/ 5/2024 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 14.80 508 233 0.23 / 17.63 5 5
2 7 2002.76 40 14.40 3240 1866 2.10 / 19.50 5 8
3 13 1417.08 20 14.50 2419 702 2.80 / 20.20 5 14
4 13 738.16 20 14.65 1458 427 3.23 / 20.63 5 18
5 13 88.68 20 14.86 498 148 3.38 / 20.78 5 19
6 8 0.12 293 14.83 354 1538 4.91 / 22.31 5 162
Average= 3.72
(KJ/cycle)

Cycle 4 GMT 22/ 4/2024 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 14.80 490 218 0.22 / 13.36 5 5
2 7 1525.00 40 14.56 2559 1490 1.71 / 14.85 9 11
3 13 1134.60 20 14.61 2009 587 2.29 / 15.43 5 13
4 13 576.96 20 14.72 1205 355 2.65 / 15.79 5 17
5 13 47.24 20 14.89 423 126 2.78 / 15.91 5 19
6 8 0.04 287 14.84 349 1486 4.26 / 17.40 5 136
Average= 3.48
(KJ/cycle)

Cycle 3 GMT 21/ 4/2024 7:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 14.80 480 213 0.21 / 9.07 5 5
2 7 1525.60 41 14.56 2555 1525 1.74 / 10.60 5 12
3 13 1210.56 20 14.59 2109 615 2.35 / 11.21 5 13
4 13 537.12 20 14.74 1149 339 2.69 / 11.55 5 17
5 13 42.36 20 14.90 410 122 2.81 / 11.67 5 18
6 8 0.08 289 14.84 342 1467 4.28 / 13.14 5 148
Average= 3.28
(KJ/cycle)

Cycle 2 GMT 19/ 4/2024 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 31 14.84 474 218 0.22 / 4.79 5 5
2 7 1506.12 40 14.57 2540 1480 1.70 / 6.27 5 11
3 13 1189.88 20 14.60 2080 607 2.31 / 6.88 5 13
4 13 720.52 20 14.68 1412 415 2.72 / 7.30 5 16
5 13 43.28 20 14.90 414 123 2.84 / 7.42 5 14
6 8 0.00 289 14.84 335 1437 4.28 / 8.86 5 157
Average= 2.95
(KJ/cycle)

Cycle 1 GMT 18/ 4/2024 11:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 15.03 461 215 0.21 / 1.98 5 5
2 3 965.16 -1 15.30 0 0 0.00 / 1.98 5 5
3 7 994.52 40 14.70 1792 1054 1.27 / 3.03 5 13
4 13 53.08 20 14.96 411 123 1.39 / 3.15 5 15
5 8 0.00 291 14.91 328 1423 2.81 / 4.58 5 160
Average= 2.29
(KJ/cycle)

Cycle 0 GMT 18/ 4/2024 1:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.60 30 15.22 397 181 0.18 / 0.18 5 5
2 7 81.76 40 15.20 409 249 0.43 / 0.43 5 5
3 13 43.92 20 15.20 348 106 0.54 / 0.54 5 7
4 8 0.16 282 15.15 287 1226 1.76 / 1.76 5 153
Average= 1.76
(KJ/cycle)