1 | 2 | 112.96 | 33 | 14.71 | 480 | 233 | 0.23 / 176.76 | 5 | 6 |
2 | 3 | 1027.52 | 1 | 14.71 | 1713 | 25 | 0.26 / 176.79 | 5 | 10 |
3 | 7 | 2003.44 | 40 | 14.35 | 2990 | 1716 | 1.97 / 178.50 | 10 | 10 |
4 | 13 | 1456.08 | 20 | 14.42 | 2274 | 656 | 2.63 / 179.16 | 5 | 14 |
5 | 13 | 914.20 | 20 | 14.52 | 1571 | 456 | 3.09 / 179.61 | 5 | 18 |
6 | 13 | 242.84 | 20 | 14.74 | 656 | 193 | 3.28 / 179.81 | 5 | 18 |
7 | 8 | 0.00 | 297 | 14.77 | 308 | 1351 | 4.63 / 181.16 | 5 | 140 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 34 | 14.71 | 471 | 236 | 0.24 / 171.93 | 5 | 6 |
2 | 3 | 933.40 | -1 | 15.20 | 1 | 0 | 0.00 / 171.93 | 5 | 6 |
3 | 7 | 2006.32 | 40 | 14.34 | 2996 | 1719 | 1.95 / 173.65 | 6 | 10 |
4 | 13 | 1538.68 | 20 | 14.39 | 2407 | 693 | 2.65 / 174.34 | 5 | 13 |
5 | 13 | 967.60 | 20 | 14.50 | 1636 | 474 | 3.12 / 174.82 | 5 | 19 |
6 | 13 | 382.00 | 20 | 14.67 | 865 | 254 | 3.38 / 175.07 | 5 | 21 |
7 | 8 | 0.24 | 310 | 14.75 | 319 | 1459 | 4.83 / 176.53 | 5 | 135 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 34 | 14.73 | 478 | 239 | 0.24 / 167.16 | 5 | 6 |
2 | 7 | 2005.72 | 40 | 14.35 | 2994 | 1719 | 1.96 / 168.88 | 6 | 9 |
3 | 13 | 1441.56 | 20 | 14.42 | 2274 | 656 | 2.61 / 169.54 | 5 | 13 |
4 | 13 | 860.80 | 20 | 14.54 | 1512 | 440 | 3.05 / 169.98 | 5 | 18 |
5 | 13 | 408.32 | 20 | 14.67 | 899 | 264 | 3.32 / 170.24 | 5 | 20 |
6 | 8 | -0.08 | 312 | 14.75 | 316 | 1454 | 4.77 / 171.69 | 5 | 140 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 35 | 14.74 | 451 | 233 | 0.23 / 162.47 | 5 | 6 |
2 | 7 | 2008.84 | 40 | 14.35 | 3001 | 1723 | 1.96 / 164.19 | 6 | 10 |
3 | 13 | 1464.04 | 20 | 14.42 | 2290 | 660 | 2.62 / 164.85 | 5 | 13 |
4 | 13 | 888.04 | 20 | 14.53 | 1551 | 451 | 3.07 / 165.30 | 5 | 18 |
5 | 13 | 293.12 | 20 | 14.72 | 742 | 218 | 3.28 / 165.52 | 5 | 20 |
6 | 8 | 0.12 | 300 | 14.77 | 316 | 1400 | 4.69 / 166.92 | 5 | 148 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 35 | 14.74 | 461 | 238 | 0.24 / 157.74 | 5 | 6 |
2 | 7 | 2016.96 | 40 | 14.35 | 3007 | 1726 | 1.96 / 159.46 | 6 | 9 |
3 | 13 | 1464.88 | 20 | 14.42 | 2311 | 666 | 2.63 / 160.13 | 5 | 13 |
4 | 13 | 915.96 | 20 | 14.53 | 1576 | 458 | 3.09 / 160.59 | 5 | 18 |
5 | 13 | 345.00 | 20 | 14.70 | 810 | 238 | 3.33 / 160.82 | 5 | 20 |
6 | 13 | 25.24 | 20 | 14.82 | 361 | 107 | 3.43 / 160.93 | 5 | 18 |
7 | 8 | 0.04 | 280 | 14.76 | 316 | 1306 | 4.74 / 162.24 | 5 | 143 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 35 | 14.74 | 479 | 247 | 0.25 / 152.94 | 5 | 6 |
2 | 7 | 2015.68 | 41 | 14.35 | 3003 | 1767 | 2.01 / 154.71 | 6 | 9 |
3 | 13 | 1382.40 | 20 | 14.44 | 2188 | 632 | 2.65 / 155.34 | 5 | 14 |
4 | 13 | 1040.48 | 20 | 14.49 | 1740 | 504 | 3.15 / 155.85 | 5 | 16 |
5 | 13 | 426.20 | 20 | 14.67 | 920 | 270 | 3.42 / 156.12 | 5 | 19 |
6 | 8 | 0.12 | 297 | 14.77 | 315 | 1382 | 4.80 / 157.50 | 5 | 144 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 36 | 14.76 | 443 | 235 | 0.24 / 148.01 | 5 | 5 |
2 | 7 | 2009.48 | 40 | 14.36 | 2991 | 1718 | 1.95 / 149.73 | 5 | 9 |
3 | 13 | 1536.44 | 20 | 14.41 | 2393 | 690 | 2.64 / 150.42 | 5 | 12 |
4 | 13 | 1063.76 | 20 | 14.49 | 1777 | 515 | 3.16 / 150.93 | 5 | 17 |
5 | 13 | 571.28 | 20 | 14.63 | 1115 | 326 | 3.48 / 151.26 | 5 | 19 |
6 | 8 | 0.20 | 306 | 14.77 | 318 | 1437 | 4.92 / 152.70 | 5 | 137 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 35 | 14.77 | 454 | 235 | 0.23 / 143.15 | 5 | 5 |
2 | 7 | 2031.04 | 40 | 14.36 | 3020 | 1735 | 1.97 / 144.89 | 6 | 8 |
3 | 13 | 1831.92 | 20 | 14.35 | 2776 | 797 | 2.77 / 145.69 | 5 | 10 |
4 | 13 | 1086.12 | 20 | 14.50 | 1789 | 519 | 3.28 / 146.20 | 5 | 16 |
5 | 13 | 372.80 | 20 | 14.71 | 844 | 248 | 3.53 / 146.45 | 5 | 18 |
6 | 8 | -0.04 | 291 | 14.80 | 307 | 1322 | 4.86 / 147.77 | 5 | 143 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 36 | 14.76 | 447 | 238 | 0.24 / 138.45 | 5 | 5 |
2 | 3 | 965.16 | -1 | 15.22 | 1 | 0 | 0.00 / 138.45 | 5 | 5 |
3 | 7 | 2005.28 | 40 | 14.37 | 2985 | 1716 | 1.95 / 140.16 | 5 | 8 |
4 | 13 | 1556.60 | 20 | 14.43 | 2400 | 693 | 2.65 / 140.86 | 5 | 13 |
5 | 13 | 994.44 | 20 | 14.53 | 1675 | 487 | 3.13 / 141.34 | 5 | 16 |
6 | 13 | 421.32 | 20 | 14.70 | 912 | 268 | 3.40 / 141.61 | 5 | 17 |
7 | 8 | 0.20 | 287 | 14.80 | 308 | 1308 | 4.71 / 142.92 | 5 | 143 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 36 | 14.81 | 442 | 236 | 0.24 / 133.79 | 5 | 5 |
2 | 3 | 1031.48 | 1 | 14.82 | 1686 | 25 | 0.26 / 133.81 | 5 | 7 |
3 | 7 | 2013.44 | 40 | 14.36 | 3000 | 1723 | 1.98 / 135.54 | 7 | 9 |
4 | 13 | 1455.12 | 20 | 14.43 | 2267 | 654 | 2.64 / 136.19 | 5 | 13 |
5 | 13 | 1018.56 | 20 | 14.51 | 1698 | 493 | 3.13 / 136.68 | 5 | 16 |
6 | 13 | 282.92 | 20 | 14.74 | 713 | 210 | 3.34 / 136.89 | 5 | 17 |
7 | 8 | 0.12 | 291 | 14.79 | 306 | 1317 | 4.66 / 138.21 | 5 | 137 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 35 | 14.79 | 472 | 244 | 0.24 / 129.21 | 5 | 6 |
2 | 3 | 1024.08 | 1 | 14.77 | 1703 | 25 | 0.27 / 129.23 | 5 | 8 |
3 | 7 | 2014.12 | 40 | 14.40 | 2992 | 1723 | 1.99 / 130.96 | 8 | 7 |
4 | 13 | 1490.36 | 20 | 14.45 | 2309 | 667 | 2.66 / 131.62 | 5 | 10 |
5 | 13 | 1042.32 | 20 | 14.53 | 1735 | 504 | 3.16 / 132.13 | 5 | 15 |
6 | 13 | 347.40 | 20 | 14.77 | 787 | 232 | 3.40 / 132.36 | 5 | 11 |
7 | 8 | 0.24 | 274 | 14.84 | 293 | 1191 | 4.59 / 133.55 | 5 | 135 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 34 | 14.77 | 482 | 242 | 0.24 / 124.54 | 5 | 6 |
2 | 3 | 1040.08 | 1 | 14.77 | 1719 | 25 | 0.27 / 124.56 | 5 | 11 |
3 | 7 | 2012.32 | 40 | 14.39 | 2988 | 1720 | 1.99 / 126.28 | 11 | 9 |
4 | 13 | 1452.28 | 20 | 14.45 | 2288 | 661 | 2.65 / 126.94 | 5 | 12 |
5 | 13 | 974.12 | 20 | 14.54 | 1658 | 482 | 3.13 / 127.42 | 5 | 16 |
6 | 13 | 395.44 | 20 | 14.73 | 869 | 256 | 3.39 / 127.68 | 5 | 16 |
7 | 8 | 0.32 | 285 | 14.82 | 304 | 1284 | 4.67 / 128.96 | 5 | 141 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 34 | 14.76 | 464 | 233 | 0.23 / 119.86 | 5 | 6 |
2 | 7 | 2010.56 | 40 | 14.38 | 3006 | 1729 | 1.96 / 121.58 | 6 | 10 |
3 | 13 | 1552.60 | 20 | 14.44 | 2394 | 691 | 2.65 / 122.28 | 5 | 13 |
4 | 13 | 877.96 | 20 | 14.58 | 1531 | 446 | 3.10 / 122.72 | 5 | 17 |
5 | 13 | 309.32 | 20 | 14.75 | 749 | 221 | 3.32 / 122.94 | 5 | 17 |
6 | 8 | 0.12 | 295 | 14.81 | 309 | 1350 | 4.67 / 124.29 | 5 | 137 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 34 | 14.77 | 467 | 235 | 0.23 / 115.19 | 5 | 6 |
2 | 7 | 2004.20 | 40 | 14.38 | 3002 | 1727 | 1.96 / 116.91 | 6 | 9 |
3 | 13 | 1453.56 | 20 | 14.45 | 2294 | 663 | 2.62 / 117.58 | 5 | 13 |
4 | 13 | 891.64 | 20 | 14.57 | 1541 | 449 | 3.07 / 118.03 | 5 | 17 |
5 | 13 | 234.52 | 20 | 14.77 | 655 | 193 | 3.27 / 118.22 | 5 | 18 |
6 | 8 | 0.04 | 302 | 14.80 | 314 | 1403 | 4.67 / 119.62 | 5 | 139 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 34 | 14.77 | 453 | 227 | 0.23 / 110.42 | 5 | 6 |
2 | 7 | 2004.84 | 40 | 14.39 | 3001 | 1727 | 1.95 / 112.15 | 6 | 9 |
3 | 13 | 1559.24 | 20 | 14.43 | 2428 | 701 | 2.66 / 112.85 | 5 | 12 |
4 | 13 | 1075.64 | 20 | 14.52 | 1800 | 523 | 3.18 / 113.37 | 5 | 17 |
5 | 13 | 254.08 | 20 | 14.78 | 678 | 200 | 3.38 / 113.57 | 5 | 19 |
6 | 8 | -0.04 | 302 | 14.81 | 309 | 1382 | 4.76 / 114.95 | 5 | 133 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 34 | 14.75 | 488 | 245 | 0.24 / 105.68 | 5 | 6 |
2 | 7 | 2015.72 | 40 | 14.39 | 3016 | 1736 | 1.98 / 107.42 | 6 | 9 |
3 | 13 | 1459.24 | 20 | 14.46 | 2288 | 662 | 2.64 / 108.08 | 5 | 14 |
4 | 13 | 999.36 | 20 | 14.54 | 1686 | 490 | 3.13 / 108.57 | 5 | 17 |
5 | 13 | 280.52 | 20 | 14.76 | 724 | 214 | 3.35 / 108.78 | 5 | 19 |
6 | 8 | -0.04 | 304 | 14.80 | 313 | 1408 | 4.75 / 110.19 | 5 | 146 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 34 | 14.76 | 495 | 248 | 0.25 / 100.85 | 5 | 6 |
2 | 7 | 2014.16 | 40 | 14.38 | 3008 | 1730 | 1.98 / 102.58 | 5 | 9 |
3 | 13 | 1452.96 | 20 | 14.45 | 2299 | 664 | 2.64 / 103.24 | 5 | 13 |
4 | 13 | 876.64 | 20 | 14.58 | 1540 | 449 | 3.09 / 103.69 | 5 | 17 |
5 | 13 | 406.72 | 20 | 14.72 | 897 | 264 | 3.36 / 103.95 | 5 | 20 |
6 | 8 | 0.00 | 310 | 14.80 | 323 | 1482 | 4.84 / 105.44 | 5 | 140 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 34 | 14.78 | 460 | 231 | 0.23 / 96.12 | 5 | 6 |
2 | 7 | 2006.76 | 40 | 14.38 | 3008 | 1730 | 1.96 / 97.85 | 6 | 9 |
3 | 13 | 1459.88 | 20 | 14.47 | 2283 | 661 | 2.62 / 98.51 | 5 | 13 |
4 | 13 | 909.16 | 20 | 14.58 | 1574 | 459 | 3.08 / 98.97 | 5 | 17 |
5 | 13 | 238.52 | 20 | 14.79 | 664 | 196 | 3.28 / 99.17 | 5 | 18 |
6 | 8 | 0.20 | 308 | 14.81 | 314 | 1432 | 4.71 / 100.60 | 5 | 149 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 34 | 14.77 | 492 | 247 | 0.25 / 91.41 | 5 | 6 |
2 | 3 | 1024.84 | 1 | 14.77 | 1722 | 25 | 0.27 / 91.43 | 5 | 8 |
3 | 7 | 2008.36 | 40 | 14.40 | 2989 | 1722 | 1.99 / 93.15 | 8 | 9 |
4 | 13 | 1558.64 | 20 | 14.46 | 2397 | 693 | 2.69 / 93.85 | 5 | 12 |
5 | 13 | 880.00 | 20 | 14.59 | 1544 | 451 | 3.14 / 94.30 | 5 | 17 |
6 | 13 | 328.96 | 20 | 14.76 | 784 | 231 | 3.37 / 94.53 | 5 | 17 |
7 | 8 | 0.00 | 295 | 14.82 | 311 | 1360 | 4.73 / 95.89 | 5 | 142 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 33 | 14.80 | 459 | 224 | 0.22 / 86.63 | 5 | 6 |
2 | 7 | 2011.04 | 40 | 14.40 | 2989 | 1722 | 1.95 / 88.36 | 5 | 9 |
3 | 13 | 1449.44 | 20 | 14.47 | 2285 | 661 | 2.61 / 89.02 | 5 | 12 |
4 | 13 | 981.80 | 20 | 14.55 | 1680 | 489 | 3.10 / 89.51 | 5 | 17 |
5 | 13 | 371.68 | 20 | 14.74 | 843 | 249 | 3.34 / 89.75 | 5 | 18 |
6 | 8 | 0.04 | 300 | 14.82 | 316 | 1405 | 4.75 / 91.16 | 5 | 140 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 34 | 14.78 | 460 | 231 | 0.23 / 81.92 | 5 | 6 |
2 | 3 | 950.76 | -1 | 15.25 | 1 | 0 | 0.00 / 81.92 | 5 | 6 |
3 | 7 | 2014.36 | 41 | 14.39 | 3015 | 1779 | 2.01 / 83.70 | 6 | 9 |
4 | 13 | 1425.36 | 20 | 14.48 | 2252 | 652 | 2.66 / 84.35 | 5 | 13 |
5 | 13 | 966.80 | 20 | 14.57 | 1651 | 481 | 3.14 / 84.83 | 5 | 17 |
6 | 13 | 269.52 | 20 | 14.79 | 704 | 208 | 3.35 / 85.04 | 5 | 17 |
7 | 8 | 0.12 | 295 | 14.83 | 313 | 1369 | 4.72 / 86.41 | 5 | 145 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 35 | 14.80 | 463 | 240 | 0.24 / 77.22 | 5 | 6 |
2 | 3 | 966.84 | -1 | 15.26 | 1 | 0 | 0.00 / 77.22 | 5 | 6 |
3 | 7 | 2012.28 | 40 | 14.40 | 3013 | 1735 | 1.98 / 78.96 | 6 | 9 |
4 | 13 | 1478.72 | 20 | 14.48 | 2311 | 669 | 2.64 / 79.62 | 5 | 12 |
5 | 13 | 828.20 | 20 | 14.61 | 1469 | 429 | 3.07 / 80.05 | 5 | 17 |
6 | 13 | 276.16 | 20 | 14.78 | 720 | 213 | 3.29 / 80.27 | 5 | 18 |
7 | 8 | 0.00 | 306 | 14.81 | 314 | 1423 | 4.71 / 81.69 | 5 | 137 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 35 | 14.84 | 451 | 234 | 0.23 / 72.50 | 5 | 5 |
2 | 7 | 2004.40 | 40 | 14.42 | 2980 | 1719 | 1.95 / 74.21 | 6 | 8 |
3 | 13 | 1636.96 | 20 | 14.45 | 2522 | 729 | 2.68 / 74.94 | 5 | 12 |
4 | 13 | 946.20 | 20 | 14.59 | 1612 | 470 | 3.15 / 75.41 | 5 | 16 |
5 | 13 | 289.68 | 20 | 14.79 | 724 | 214 | 3.37 / 75.63 | 5 | 16 |
6 | 8 | 0.00 | 293 | 14.84 | 311 | 1352 | 4.72 / 76.98 | 5 | 143 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 34 | 14.81 | 470 | 237 | 0.24 / 67.84 | 5 | 6 |
2 | 10 | 1010.72 | 3 | 14.76 | 1703 | 75 | 0.31 / 67.92 | 5 | 8 |
3 | 3 | 966.32 | -1 | 15.27 | 1 | 0 | 0.08 / 67.92 | 5 | 8 |
4 | 7 | 2015.00 | 40 | 14.41 | 3023 | 1742 | 2.05 / 69.66 | 8 | 8 |
5 | 13 | 1473.88 | 20 | 14.48 | 2322 | 672 | 2.73 / 70.33 | 5 | 13 |
6 | 13 | 913.48 | 20 | 14.60 | 1567 | 458 | 3.18 / 70.79 | 5 | 16 |
7 | 13 | 231.60 | 20 | 14.82 | 645 | 191 | 3.38 / 70.98 | 5 | 14 |
8 | 8 | 1.76 | 282 | 14.85 | 306 | 1281 | 4.66 / 72.26 | 5 | 141 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 34 | 14.78 | 471 | 237 | 0.24 / 63.22 | 5 | 6 |
2 | 7 | 2007.76 | 40 | 14.42 | 3014 | 1738 | 1.98 / 64.96 | 6 | 8 |
3 | 13 | 1443.60 | 20 | 14.50 | 2275 | 660 | 2.63 / 65.62 | 5 | 13 |
4 | 13 | 813.56 | 20 | 14.64 | 1435 | 420 | 3.06 / 66.04 | 5 | 16 |
5 | 13 | 357.76 | 20 | 14.78 | 829 | 245 | 3.30 / 66.29 | 5 | 17 |
6 | 8 | 0.12 | 289 | 14.85 | 307 | 1318 | 4.62 / 67.60 | 5 | 135 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 35 | 14.80 | 462 | 239 | 0.24 / 58.38 | 5 | 6 |
2 | 7 | 2005.56 | 40 | 14.42 | 3004 | 1733 | 1.97 / 60.12 | 6 | 8 |
3 | 13 | 1454.32 | 20 | 14.50 | 2275 | 660 | 2.63 / 60.78 | 5 | 12 |
4 | 13 | 891.00 | 20 | 14.60 | 1556 | 454 | 3.09 / 61.23 | 5 | 17 |
5 | 13 | 413.80 | 20 | 14.74 | 909 | 268 | 3.35 / 61.50 | 5 | 19 |
6 | 8 | -0.12 | 311 | 14.82 | 323 | 1489 | 4.84 / 62.99 | 5 | 148 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 34 | 14.82 | 465 | 234 | 0.23 / 53.71 | 5 | 5 |
2 | 7 | 2014.12 | 40 | 14.43 | 3005 | 1734 | 1.97 / 55.45 | 5 | 9 |
3 | 13 | 1451.68 | 20 | 14.50 | 2278 | 661 | 2.63 / 56.11 | 5 | 13 |
4 | 13 | 1002.20 | 20 | 14.58 | 1677 | 489 | 3.12 / 56.60 | 5 | 17 |
5 | 13 | 211.16 | 20 | 14.83 | 622 | 184 | 3.30 / 56.78 | 5 | 16 |
6 | 8 | 0.16 | 295 | 14.84 | 311 | 1361 | 4.66 / 58.14 | 5 | 140 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 36 | 14.82 | 458 | 244 | 0.24 / 49.01 | 5 | 5 |
2 | 3 | 943.52 | -1 | 15.28 | 1 | 0 | 0.00 / 49.01 | 5 | 5 |
3 | 7 | 2010.00 | 41 | 14.42 | 3008 | 1778 | 2.02 / 50.79 | 5 | 8 |
4 | 13 | 1550.60 | 20 | 14.49 | 2411 | 699 | 2.72 / 51.49 | 5 | 12 |
5 | 13 | 868.08 | 20 | 14.62 | 1512 | 442 | 3.16 / 51.93 | 5 | 17 |
6 | 13 | 297.72 | 20 | 14.80 | 739 | 219 | 3.38 / 52.15 | 5 | 16 |
7 | 8 | -0.04 | 287 | 14.85 | 312 | 1330 | 4.71 / 53.48 | 5 | 141 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 36 | 14.86 | 444 | 238 | 0.24 / 44.35 | 5 | 5 |
2 | 7 | 2012.60 | 41 | 14.43 | 2995 | 1772 | 2.01 / 46.12 | 5 | 8 |
3 | 13 | 1457.88 | 20 | 14.50 | 2290 | 664 | 2.67 / 46.78 | 5 | 12 |
4 | 13 | 977.56 | 20 | 14.58 | 1663 | 485 | 3.16 / 47.27 | 5 | 16 |
5 | 13 | 177.60 | 20 | 14.84 | 571 | 169 | 3.33 / 47.44 | 5 | 15 |
6 | 8 | -0.04 | 289 | 14.85 | 310 | 1330 | 4.66 / 48.77 | 5 | 164 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 36 | 14.87 | 459 | 246 | 0.25 / 39.71 | 5 | 5 |
2 | 7 | 2008.52 | 41 | 14.46 | 2982 | 1768 | 2.01 / 41.48 | 5 | 7 |
3 | 13 | 1544.40 | 20 | 14.50 | 2402 | 697 | 2.71 / 42.18 | 5 | 11 |
4 | 13 | 969.96 | 20 | 14.61 | 1635 | 478 | 3.19 / 42.65 | 5 | 14 |
5 | 13 | 280.96 | 20 | 14.84 | 707 | 210 | 3.40 / 42.86 | 5 | 10 |
6 | 13 | 34.36 | 20 | 14.92 | 355 | 106 | 3.50 / 42.97 | 5 | 10 |
7 | 8 | 0.08 | 255 | 14.88 | 300 | 1138 | 4.64 / 44.11 | 5 | 140 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 36 | 14.87 | 453 | 242 | 0.24 / 35.17 | 5 | 5 |
2 | 7 | 2009.32 | 40 | 14.46 | 3007 | 1739 | 1.98 / 36.90 | 5 | 6 |
3 | 13 | 1470.80 | 20 | 14.52 | 2286 | 664 | 2.65 / 37.57 | 5 | 10 |
4 | 13 | 925.00 | 20 | 14.63 | 1576 | 461 | 3.11 / 38.03 | 5 | 13 |
5 | 13 | 333.04 | 20 | 14.83 | 768 | 228 | 3.33 / 38.26 | 5 | 10 |
6 | 8 | -0.08 | 276 | 14.90 | 294 | 1209 | 4.54 / 39.47 | 5 | 155 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 36 | 14.87 | 454 | 243 | 0.24 / 30.57 | 5 | 5 |
2 | 7 | 2010.60 | 40 | 14.47 | 3006 | 1740 | 1.98 / 32.31 | 5 | 7 |
3 | 13 | 1466.04 | 20 | 14.53 | 2299 | 668 | 2.65 / 32.97 | 5 | 10 |
4 | 13 | 1030.40 | 20 | 14.61 | 1721 | 503 | 3.15 / 33.48 | 5 | 13 |
5 | 13 | 322.48 | 20 | 14.84 | 759 | 225 | 3.38 / 33.70 | 5 | 10 |
6 | 8 | 0.28 | 274 | 14.90 | 299 | 1221 | 4.60 / 34.92 | 5 | 137 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 36 | 14.88 | 436 | 234 | 0.23 / 25.98 | 5 | 5 |
2 | 7 | 2015.48 | 40 | 14.48 | 2996 | 1735 | 1.97 / 27.71 | 5 | 7 |
3 | 13 | 1469.24 | 20 | 14.54 | 2283 | 664 | 2.63 / 28.38 | 5 | 9 |
4 | 13 | 1023.48 | 20 | 14.61 | 1703 | 498 | 3.13 / 28.88 | 5 | 12 |
5 | 13 | 303.40 | 20 | 14.85 | 724 | 215 | 3.35 / 29.09 | 5 | 9 |
6 | 13 | 17.28 | 20 | 14.94 | 325 | 97 | 3.44 / 29.19 | 5 | 9 |
7 | 8 | 0.20 | 255 | 14.90 | 299 | 1136 | 4.58 / 30.32 | 5 | 131 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 35 | 14.88 | 445 | 232 | 0.23 / 21.38 | 5 | 5 |
2 | 3 | 1032.04 | 1 | 14.91 | 1719 | 26 | 0.26 / 21.40 | 5 | 6 |
3 | 7 | 2013.28 | 40 | 14.48 | 2992 | 1733 | 1.99 / 23.14 | 6 | 7 |
4 | 13 | 1575.36 | 20 | 14.53 | 2417 | 702 | 2.69 / 23.84 | 5 | 9 |
5 | 13 | 1010.16 | 20 | 14.63 | 1680 | 492 | 3.18 / 24.33 | 5 | 12 |
6 | 13 | 307.88 | 20 | 14.86 | 725 | 215 | 3.40 / 24.55 | 5 | 9 |
7 | 8 | 0.24 | 276 | 14.91 | 291 | 1198 | 4.60 / 25.74 | 5 | 139 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 31 | 14.89 | 451 | 208 | 0.21 / 16.63 | 5 | 5 |
2 | 10 | 1005.64 | 5 | 14.85 | 1678 | 125 | 0.33 / 16.75 | 5 | 5 |
3 | 7 | 2006.44 | 40 | 14.49 | 2979 | 1727 | 2.06 / 18.48 | 5 | 6 |
4 | 13 | 1561.20 | 20 | 14.51 | 2429 | 705 | 2.76 / 19.18 | 5 | 9 |
5 | 13 | 1079.28 | 20 | 14.60 | 1779 | 519 | 3.28 / 19.70 | 5 | 12 |
6 | 13 | 349.96 | 20 | 14.84 | 788 | 234 | 3.52 / 19.94 | 5 | 10 |
7 | 8 | 0.08 | 278 | 14.91 | 292 | 1210 | 4.73 / 21.15 | 5 | 147 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 35 | 14.88 | 448 | 233 | 0.23 / 12.61 | 5 | 5 |
2 | 7 | 1511.64 | 41 | 14.70 | 2334 | 1407 | 1.64 / 14.02 | 5 | 6 |
3 | 13 | 1425.96 | 20 | 14.67 | 2210 | 648 | 2.29 / 14.67 | 5 | 7 |
4 | 13 | 846.56 | 20 | 14.75 | 1457 | 430 | 2.72 / 15.09 | 5 | 10 |
5 | 13 | 141.08 | 20 | 14.94 | 494 | 148 | 2.87 / 15.24 | 5 | 8 |
6 | 13 | 12.20 | 20 | 14.98 | 310 | 93 | 2.96 / 15.34 | 5 | 8 |
7 | 8 | 0.04 | 253 | 14.93 | 287 | 1084 | 4.04 / 16.42 | 5 | 144 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 35 | 14.87 | 424 | 221 | 0.22 / 8.55 | 5 | 5 |
2 | 3 | 1019.48 | 1 | 14.91 | 1687 | 25 | 0.25 / 8.57 | 5 | 5 |
3 | 7 | 1506.80 | 40 | 14.70 | 2334 | 1372 | 1.62 / 9.94 | 5 | 7 |
4 | 13 | 1419.92 | 20 | 14.67 | 2212 | 649 | 2.27 / 10.59 | 5 | 8 |
5 | 13 | 856.28 | 20 | 14.74 | 1475 | 435 | 2.70 / 11.03 | 5 | 10 |
6 | 13 | 152.68 | 20 | 14.93 | 508 | 152 | 2.85 / 11.18 | 5 | 8 |
7 | 13 | 14.44 | 20 | 14.97 | 317 | 95 | 2.95 / 11.27 | 5 | 9 |
8 | 8 | 0.08 | 253 | 14.92 | 292 | 1102 | 4.05 / 12.38 | 5 | 132 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 31 | 14.90 | 423 | 195 | 0.20 / 4.44 | 5 | 5 |
2 | 10 | 1032.28 | 4 | 14.83 | 1693 | 100 | 0.30 / 4.54 | 5 | 5 |
3 | 3 | 1024.40 | 1 | 14.90 | 1661 | 25 | 0.32 / 4.57 | 5 | 5 |
4 | 7 | 1519.28 | 40 | 14.68 | 2344 | 1376 | 1.70 / 5.94 | 5 | 6 |
5 | 13 | 1430.28 | 20 | 14.65 | 2224 | 652 | 2.35 / 6.60 | 5 | 8 |
6 | 13 | 860.72 | 20 | 14.73 | 1474 | 434 | 2.78 / 7.03 | 5 | 10 |
7 | 13 | 162.16 | 20 | 14.91 | 519 | 155 | 2.94 / 7.18 | 5 | 8 |
8 | 13 | 14.00 | 20 | 14.96 | 306 | 92 | 3.03 / 7.28 | 5 | 9 |
9 | 8 | 0.08 | 253 | 14.92 | 278 | 1049 | 4.08 / 8.33 | 5 | 140 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 31 | 15.07 | 425 | 199 | 0.20 / 1.89 | 5 | 6 |
2 | 10 | 1025.36 | 4 | 14.88 | 1652 | 98 | 0.30 / 1.98 | 5 | 5 |
3 | 7 | 1003.20 | 40 | 14.80 | 1653 | 979 | 1.28 / 2.96 | 5 | 9 |
4 | 13 | 110.16 | 20 | 14.99 | 443 | 133 | 1.41 / 3.10 | 5 | 8 |
5 | 8 | 0.20 | 270 | 14.96 | 285 | 1151 | 2.56 / 4.25 | 5 | 149 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 30 | 15.26 | 423 | 194 | 0.19 / 0.19 | 5 | 6 |
2 | 7 | 133.28 | 40 | 15.23 | 437 | 266 | 0.46 / 0.46 | 6 | 5 |
3 | 13 | 82.20 | 20 | 15.22 | 378 | 115 | 0.57 / 0.57 | 5 | 5 |
4 | 8 | 0.12 | 280 | 15.17 | 262 | 1113 | 1.69 / 1.69 | 5 | 142 |
Average= | 1.69 (KJ/cycle) |