SIO Argo Site:
Pump Diagnostics Page   



Serial= 7902 WMO= 2903438

Return

←PreviousNext→

Cycle 39 GMT 18/ 4/2025 20:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 35 14.39 1144 576 0.58 / 258.37 5 5
2 3 966.32 -1 15.12 0 0 0.00 / 258.37 5 5
3 7 2011.04 40 14.08 4121 2321 2.90 / 260.69 5 5
4 13 1439.64 20 14.18 3265 926 3.82 / 261.61 4 7
5 13 854.76 20 14.30 2415 691 4.51 / 262.30 4 9
6 13 186.20 20 14.52 1327 385 4.90 / 262.69 4 13
7 8 0.16 287 14.43 946 3918 8.82 / 266.61 5 134
Average= 6.67
(KJ/cycle)

Cycle 38 GMT 8/ 4/2025 14:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 35 14.41 1097 553 0.55 / 249.59 5 5
2 7 2009.36 40 14.09 4117 2320 2.87 / 251.91 5 5
3 13 1441.68 20 14.19 3274 929 3.80 / 252.84 4 7
4 13 873.48 20 14.31 2380 681 4.48 / 253.52 4 9
5 13 291.04 20 14.49 1467 425 4.91 / 253.95 4 11
6 8 0.08 287 14.44 928 3846 8.75 / 257.79 5 135
Average= 6.61
(KJ/cycle)

Cycle 37 GMT 29/ 3/2025 8:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 37 14.46 1018 545 0.54 / 240.79 5 5
2 3 951.64 -1 15.15 0 0 0.00 / 240.79 5 5
3 7 2010.00 40 14.08 4147 2336 2.88 / 243.12 5 5
4 13 1546.32 20 14.15 3470 982 3.86 / 244.11 4 6
5 13 876.24 20 14.31 2393 685 4.55 / 244.79 4 9
6 13 314.88 20 14.48 1511 438 4.98 / 245.23 4 11
7 8 0.12 287 14.45 918 3807 8.79 / 249.04 5 134
Average= 6.55
(KJ/cycle)

Cycle 36 GMT 19/ 3/2025 2: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 36 14.48 1020 532 0.53 / 232.02 5 5
2 7 2009.72 40 14.09 4147 2337 2.87 / 234.36 5 5
3 13 1462.44 20 14.17 3365 954 3.82 / 235.31 4 6
4 13 996.40 20 14.27 2601 742 4.56 / 236.06 4 8
5 13 187.44 20 14.57 1317 384 4.95 / 236.44 5 8
6 8 0.08 291 14.49 902 3803 8.75 / 240.24 5 158
Average= 6.49
(KJ/cycle)

Cycle 35 GMT 8/ 3/2025 19:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 34 14.50 1131 558 0.56 / 223.02 5 5
2 10 1041.08 3 14.52 2605 113 0.67 / 223.14 5 5
3 7 2017.68 40 14.11 4121 2326 3.00 / 225.46 5 5
4 13 1572.44 20 14.16 3511 994 3.99 / 226.46 4 6
5 13 1085.80 20 14.25 2742 781 4.77 / 227.24 4 8
6 13 363.16 20 14.52 1574 457 5.23 / 227.70 5 9
7 8 0.16 295 14.51 887 3797 9.03 / 231.49 5 138
Average= 6.43
(KJ/cycle)

Cycle 34 GMT 26/ 2/2025 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 34 14.45 1059 520 0.52 / 214.22 5 5
2 7 2012.84 41 14.11 4130 2389 2.91 / 216.61 5 6
3 13 1446.88 20 14.21 3322 944 3.85 / 217.56 4 6
4 13 980.44 20 14.31 2577 738 4.59 / 218.29 4 8
5 13 243.24 20 14.58 1396 407 5.00 / 218.70 5 8
6 8 0.16 291 14.52 891 3765 8.76 / 222.47 5 142
Average= 6.36
(KJ/cycle)

Cycle 33 GMT 16/ 2/2025 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 14.43 1038 509 0.51 / 205.74 5 5
2 7 2011.40 41 14.11 4090 2366 2.88 / 208.11 5 6
3 13 1361.52 20 14.23 3115 887 3.76 / 208.99 4 7
4 13 908.16 20 14.33 2413 692 4.45 / 209.68 4 8
5 13 144.24 20 14.59 1188 347 4.80 / 210.03 4 10
6 8 0.04 285 14.49 889 3671 8.47 / 213.70 5 135
Average= 6.29
(KJ/cycle)

Cycle 32 GMT 6/ 2/2025 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 34 14.47 1026 505 0.50 / 197.24 5 5
2 7 2003.36 40 14.12 4039 2281 2.79 / 199.52 5 5
3 13 1433.04 20 14.22 3214 914 3.70 / 200.43 4 7
4 13 843.64 20 14.35 2291 658 4.36 / 201.09 4 10
5 13 364.68 20 14.50 1496 434 4.79 / 201.52 4 12
6 13 17.76 20 14.62 950 278 5.07 / 201.80 4 14
7 8 0.00 267 14.47 888 3431 8.50 / 205.23 5 140
Average= 6.22
(KJ/cycle)

Cycle 31 GMT 26/ 1/2025 18:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 34 14.48 990 487 0.49 / 189.00 5 5
2 7 2005.92 40 14.13 4037 2282 2.77 / 191.28 5 5
3 13 1438.88 20 14.22 3218 915 3.68 / 192.20 4 6
4 13 877.96 20 14.36 2305 662 4.35 / 192.86 4 10
5 13 199.68 20 14.59 1227 358 4.70 / 193.22 4 10
6 8 0.12 287 14.52 843 3513 8.22 / 196.73 5 148
Average= 6.15
(KJ/cycle)

Cycle 30 GMT 16/ 1/2025 12:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 34 14.49 1043 514 0.51 / 180.64 5 5
2 7 2003.56 40 14.13 4045 2286 2.80 / 182.93 5 5
3 13 1528.16 20 14.20 3347 951 3.75 / 183.88 4 6
4 13 934.04 20 14.33 2465 706 4.46 / 184.58 4 8
5 13 227.00 20 14.57 1319 384 4.84 / 184.97 4 10
6 8 0.20 287 14.52 851 3546 8.39 / 188.51 5 142
Average= 6.08
(KJ/cycle)

Cycle 29 GMT 6/ 1/2025 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 34 14.50 999 493 0.49 / 172.54 5 5
2 7 2006.52 40 14.13 4003 2262 2.76 / 174.80 5 6
3 13 1437.48 20 14.24 3160 900 3.65 / 175.70 4 7
4 13 877.84 20 14.37 2306 663 4.32 / 176.36 4 8
5 13 277.00 20 14.57 1343 391 4.71 / 176.75 4 11
6 8 0.00 285 14.54 814 3373 8.08 / 180.13 5 135
Average= 6.00
(KJ/cycle)

Cycle 28 GMT 26/12/2024 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 35 14.51 1010 513 0.51 / 164.55 5 5
2 7 2012.00 40 14.14 3982 2252 2.77 / 166.80 5 5
3 13 1434.00 20 14.25 3136 894 3.66 / 167.70 4 7
4 13 963.44 20 14.35 2405 690 4.35 / 168.39 4 9
5 13 141.04 20 14.64 1085 318 4.67 / 168.71 5 9
6 8 0.12 285 14.55 805 3338 8.00 / 172.04 5 142
Average= 5.93
(KJ/cycle)

Cycle 27 GMT 16/12/2024 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 35 14.60 908 464 0.46 / 156.74 5 5
2 7 2015.40 41 14.16 3955 2296 2.76 / 159.04 5 5
3 13 1435.36 20 14.26 3080 878 3.64 / 159.92 4 7
4 13 844.16 20 14.40 2203 634 4.27 / 160.55 4 10
5 13 167.32 20 14.64 1082 317 4.59 / 160.87 5 10
6 8 0.08 285 14.57 764 3172 7.76 / 164.04 5 150
Average= 5.86
(KJ/cycle)

Cycle 26 GMT 6/12/2024 10:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 35 14.58 891 455 0.45 / 149.08 5 5
2 7 2011.52 40 14.18 3906 2215 2.67 / 151.29 5 5
3 13 1465.36 20 14.26 3140 896 3.57 / 152.19 4 7
4 13 906.76 20 14.39 2247 647 4.21 / 152.83 4 10
5 13 207.08 20 14.64 1127 330 4.54 / 153.16 5 8
6 8 -0.12 285 14.58 749 3112 7.65 / 156.28 5 138
Average= 5.79
(KJ/cycle)

Cycle 25 GMT 26/11/2024 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 35 14.64 845 433 0.43 / 141.78 5 5
2 7 2012.52 40 14.18 3873 2197 2.63 / 143.98 5 5
3 13 1447.00 20 14.28 3022 863 3.49 / 144.84 4 7
4 13 873.56 20 14.42 2109 608 4.10 / 145.45 4 8
5 13 171.32 20 14.68 993 292 4.39 / 145.74 5 8
6 8 0.16 285 14.61 692 2881 7.27 / 148.62 5 138
Average= 5.72
(KJ/cycle)

Cycle 24 GMT 15/11/2024 20: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 35 14.69 790 406 0.41 / 134.59 5 5
2 7 2004.08 41 14.21 3795 2211 2.62 / 136.80 5 5
3 13 1512.16 20 14.29 3052 872 3.49 / 137.68 4 7
4 13 825.28 20 14.46 2011 582 4.07 / 138.26 4 8
5 13 245.88 20 14.67 1068 313 4.38 / 138.57 5 8
6 8 0.76 287 14.64 661 2777 7.16 / 141.35 5 135
Average= 5.65
(KJ/cycle)

Cycle 23 GMT 5/11/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 34 14.69 763 381 0.38 / 127.49 5 5
2 3 1052.60 1 14.66 2318 34 0.42 / 127.52 4 5
3 7 2006.84 40 14.23 3771 2146 2.56 / 129.67 5 5
4 13 1652.80 20 14.28 3234 924 3.49 / 130.59 4 5
5 13 936.28 20 14.44 2142 619 4.10 / 131.21 4 7
6 13 240.92 20 14.70 1018 299 4.40 / 131.51 5 6
7 8 0.12 293 14.67 623 2678 7.08 / 134.19 5 151
Average= 5.59
(KJ/cycle)

Cycle 22 GMT 26/10/2024 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 34 14.69 783 391 0.39 / 120.67 5 5
2 7 2012.72 40 14.24 3738 2129 2.52 / 122.80 5 5
3 13 1532.20 20 14.32 3009 862 3.38 / 123.66 4 6
4 13 855.04 20 14.49 1964 569 3.95 / 124.23 4 8
5 13 274.04 20 14.69 1036 304 4.26 / 124.53 5 7
6 8 -0.08 289 14.67 607 2573 6.83 / 127.11 5 146
Average= 5.53
(KJ/cycle)

Cycle 21 GMT 15/10/2024 22:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 33 14.62 801 386 0.39 / 115.22 5 5
2 3 1029.44 1 14.65 2261 33 0.42 / 115.25 4 5
3 7 1079.76 40 14.60 2298 1342 1.76 / 116.59 5 6
4 13 1046.76 20 14.57 2266 660 2.42 / 117.25 4 7
5 13 619.84 20 14.65 1576 462 2.88 / 117.71 4 8
6 8 0.28 295 14.75 589 2563 5.45 / 120.28 5 137
Average= 5.47
(KJ/cycle)

Cycle 20 GMT 5/10/2024 13:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 33 14.63 739 357 0.36 / 108.50 5 5
2 7 2011.84 40 14.25 3691 2104 2.46 / 110.60 5 5
3 13 1509.12 20 14.34 2947 845 3.31 / 111.44 4 6
4 13 932.12 20 14.46 2059 595 3.90 / 112.04 4 8
5 13 332.40 20 14.65 1107 324 4.23 / 112.36 4 10
6 8 0.04 289 14.66 582 2466 6.69 / 114.83 5 142
Average= 5.47
(KJ/cycle)

Cycle 19 GMT 25/ 9/2024 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 33 14.63 736 355 0.36 / 101.99 5 5
2 7 2011.44 40 14.26 3666 2091 2.45 / 104.08 5 5
3 13 1360.68 20 14.38 2665 766 3.21 / 104.84 4 6
4 13 913.28 20 14.47 1999 579 3.79 / 105.42 4 8
5 13 215.08 20 14.70 907 267 4.06 / 105.69 4 11
6 8 0.20 291 14.66 574 2449 6.51 / 108.14 5 142
Average= 5.41
(KJ/cycle)

Cycle 18 GMT 14/ 9/2024 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 33 14.64 721 348 0.35 / 95.62 5 5
2 7 2006.08 40 14.26 3636 2074 2.42 / 97.69 5 5
3 13 1445.16 20 14.36 2799 804 3.23 / 98.50 4 6
4 13 852.40 20 14.49 1903 551 3.78 / 99.05 4 8
5 13 148.04 20 14.73 788 232 4.01 / 99.28 4 10
6 8 0.12 291 14.67 551 2352 6.36 / 101.63 5 146
Average= 5.35
(KJ/cycle)

Cycle 17 GMT 4/ 9/2024 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 33 14.66 694 336 0.34 / 89.40 5 5
2 7 2008.44 41 14.27 3612 2113 2.45 / 91.51 5 5
3 13 1357.24 20 14.40 2619 754 3.20 / 92.27 4 6
4 13 782.48 20 14.53 1751 509 3.71 / 92.78 4 8
5 13 119.80 20 14.75 702 207 3.92 / 92.98 4 10
6 8 0.04 291 14.69 535 2287 6.21 / 95.27 5 148
Average= 5.29
(KJ/cycle)

Cycle 16 GMT 25/ 8/2024 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 33 14.66 700 339 0.34 / 83.11 5 5
2 7 2003.68 40 14.29 3598 2057 2.40 / 85.17 5 5
3 13 1647.52 20 14.34 3059 877 3.27 / 86.04 4 6
4 13 925.96 20 14.50 1963 569 3.84 / 86.61 4 8
5 13 243.80 20 14.71 892 262 4.10 / 86.88 4 10
6 8 0.32 289 14.70 515 2188 6.29 / 89.06 5 135
Average= 5.24
(KJ/cycle)

Cycle 15 GMT 15/ 8/2024 1:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 33 14.65 671 324 0.32 / 76.85 5 5
2 7 2003.36 40 14.29 3576 2044 2.37 / 78.89 5 5
3 13 1428.32 20 14.40 2713 781 3.15 / 79.67 4 6
4 13 945.72 20 14.49 1974 572 3.72 / 80.25 4 8
5 13 240.52 20 14.71 883 260 3.98 / 80.51 4 11
6 13 20.20 20 14.79 528 156 4.14 / 80.66 4 13
7 8 0.08 274 14.69 524 2109 6.25 / 82.77 5 151
Average= 5.17
(KJ/cycle)

Cycle 14 GMT 4/ 8/2024 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 33 14.66 664 321 0.32 / 70.74 5 5
2 7 2003.60 40 14.30 3563 2038 2.36 / 72.78 5 5
3 13 1424.12 20 14.41 2695 777 3.14 / 73.55 4 6
4 13 847.20 20 14.53 1815 527 3.66 / 74.08 4 8
5 13 270.00 20 14.70 926 272 3.94 / 74.35 4 11
6 8 0.08 293 14.70 504 2171 6.11 / 76.52 4 131
Average= 5.10
(KJ/cycle)

Cycle 13 GMT 25/ 7/2024 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 33 14.68 660 320 0.32 / 64.59 5 5
2 10 1004.20 3 14.62 2023 89 0.41 / 64.68 4 5
3 3 939.40 -1 15.20 0 0 0.09 / 64.68 4 5
4 7 2005.96 40 14.31 3542 2027 2.44 / 66.71 5 5
5 13 1425.24 20 14.42 2675 771 3.21 / 67.48 4 6
6 13 945.84 20 14.51 1942 564 3.77 / 68.04 4 8
7 13 243.76 20 14.72 863 254 4.03 / 68.30 4 10
8 8 0.36 295 14.71 489 2122 6.15 / 70.42 4 147
Average= 5.03
(KJ/cycle)

Cycle 12 GMT 15/ 7/2024 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 33 14.67 654 317 0.32 / 58.60 5 5
2 7 2015.68 41 14.30 3571 2094 2.41 / 60.69 5 5
3 13 1339.32 20 14.44 2531 731 3.14 / 61.42 4 6
4 13 793.80 20 14.55 1711 498 3.64 / 61.92 4 9
5 13 318.52 20 14.69 972 286 3.92 / 62.20 4 11
6 8 -0.12 293 14.72 479 2066 5.99 / 64.27 4 135
Average= 4.94
(KJ/cycle)

Cycle 11 GMT 4/ 7/2024 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 33 14.68 640 310 0.31 / 52.68 5 5
2 7 2004.20 40 14.31 3532 2022 2.33 / 54.70 5 5
3 13 1332.72 20 14.44 2525 729 3.06 / 55.43 4 6
4 13 880.68 20 14.54 1833 533 3.59 / 55.96 4 8
5 13 269.24 20 14.72 893 263 3.86 / 56.22 4 11
6 8 -0.04 293 14.72 477 2057 5.91 / 58.28 4 132
Average= 4.86
(KJ/cycle)

Cycle 10 GMT 24/ 6/2024 16:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 33 14.70 615 298 0.30 / 46.86 5 5
2 7 2006.64 40 14.32 3524 2019 2.32 / 48.88 5 5
3 13 1428.40 20 14.43 2651 765 3.08 / 49.64 4 6
4 13 825.20 20 14.56 1738 506 3.59 / 50.15 4 8
5 13 232.52 20 14.74 820 242 3.83 / 50.39 4 11
6 8 0.00 293 14.74 458 1978 5.81 / 52.37 5 131
Average= 4.76
(KJ/cycle)

Cycle 9 GMT 14/ 6/2024 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 33 14.70 609 295 0.30 / 41.10 5 5
2 7 2003.88 40 14.33 3517 2016 2.31 / 43.11 5 5
3 13 1323.52 20 14.46 2485 719 3.03 / 43.83 4 6
4 13 877.44 20 14.54 1808 526 3.56 / 44.36 4 8
5 13 263.32 20 14.73 863 254 3.81 / 44.61 4 11
6 8 -0.08 291 14.74 454 1947 5.76 / 46.56 5 131
Average= 4.66
(KJ/cycle)

Cycle 8 GMT 4/ 6/2024 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 33 14.71 592 287 0.29 / 35.31 5 5
2 10 1003.12 3 14.63 2012 88 0.38 / 35.40 4 5
3 3 923.04 -1 15.22 0 0 0.09 / 35.40 4 5
4 7 2008.96 40 14.34 3510 2013 2.39 / 37.42 5 5
5 13 1369.44 20 14.45 2552 738 3.13 / 38.15 4 6
6 13 826.00 20 14.56 1724 502 3.63 / 38.65 4 9
7 13 224.04 20 14.75 785 232 3.86 / 38.89 4 11
8 8 0.12 293 14.75 443 1915 5.77 / 40.80 5 148
Average= 4.53
(KJ/cycle)

Cycle 7 GMT 24/ 5/2024 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 14.71 585 275 0.28 / 29.92 5 5
2 10 1001.68 4 14.63 1955 114 0.39 / 30.03 4 5
3 3 888.76 -2 15.22 0 0 0.11 / 30.03 4 5
4 7 1729.00 40 14.43 3073 1774 2.16 / 31.81 5 5
5 13 1399.60 20 14.48 2586 749 2.91 / 32.55 4 7
6 13 706.64 20 14.63 1526 447 3.36 / 33.00 4 9
7 13 140.16 20 14.81 642 190 3.55 / 33.19 4 12
8 8 0.12 291 14.77 427 1835 5.38 / 35.03 4 136
Average= 4.38
(KJ/cycle)

Cycle 6 GMT 14/ 5/2024 11:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 14.73 559 263 0.26 / 24.37 5 5
2 3 1019.52 1 14.73 2023 30 0.29 / 24.40 4 5
3 7 1972.96 40 14.36 3422 1966 2.26 / 26.36 5 5
4 13 1530.16 20 14.43 2763 797 3.06 / 27.16 4 6
5 13 747.36 20 14.60 1566 457 3.51 / 27.62 4 9
6 13 295.52 20 14.74 872 257 3.77 / 27.88 4 11
7 8 0.12 293 14.77 408 1766 5.54 / 29.64 5 144
Average= 4.23
(KJ/cycle)

Cycle 5 GMT 4/ 5/2024 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 14.76 533 244 0.24 / 19.06 5 5
2 3 1033.68 1 14.72 2019 30 0.27 / 19.09 4 5
3 7 2011.92 40 14.36 3477 1997 2.27 / 21.09 5 5
4 13 1414.20 20 14.46 2579 746 3.02 / 21.83 4 6
5 13 833.96 20 14.58 1688 492 3.51 / 22.32 4 9
6 13 144.52 20 14.81 602 178 3.69 / 22.50 4 11
7 8 -0.04 293 14.79 370 1603 5.29 / 24.11 5 160
Average= 4.02
(KJ/cycle)

Cycle 4 GMT 23/ 4/2024 19:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 14.75 524 247 0.25 / 14.45 5 5
2 7 1507.04 40 14.53 2711 1576 1.82 / 16.03 5 5
3 13 1223.60 20 14.56 2288 666 2.49 / 16.70 4 6
4 13 669.52 20 14.67 1425 418 2.91 / 17.11 4 9
5 13 82.32 20 14.85 502 149 3.06 / 17.26 4 11
6 8 0.12 287 14.81 365 1551 4.61 / 18.81 5 138
Average= 3.76
(KJ/cycle)

Cycle 3 GMT 22/ 4/2024 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 31 14.75 543 248 0.25 / 9.84 5 5
2 3 1022.28 1 14.75 1975 29 0.28 / 9.87 4 5
3 7 1506.28 40 14.53 2708 1574 1.85 / 11.44 5 5
4 13 1308.52 20 14.55 2410 701 2.55 / 12.15 4 6
5 13 624.72 20 14.68 1356 398 2.95 / 12.54 4 8
6 13 83.52 20 14.85 499 148 3.10 / 12.69 4 10
7 8 0.12 285 14.81 359 1515 4.61 / 14.21 5 130
Average= 3.55
(KJ/cycle)

Cycle 2 GMT 20/ 4/2024 23:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 14.81 524 241 0.24 / 5.22 5 5
2 7 1521.48 40 14.54 2716 1580 1.82 / 6.80 5 5
3 13 1320.92 20 14.55 2418 704 2.52 / 7.50 4 5
4 13 667.92 20 14.67 1415 415 2.94 / 7.91 4 7
5 13 61.24 20 14.86 457 136 3.07 / 8.05 4 9
6 8 0.08 287 14.81 363 1543 4.62 / 9.59 5 134
Average= 3.20
(KJ/cycle)

Cycle 1 GMT 19/ 4/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 15.02 475 221 0.22 / 2.13 5 5
2 10 1005.08 3 14.77 1950 86 0.31 / 2.21 4 5
3 3 934.12 -1 15.29 0 0 0.09 / 2.21 4 5
4 7 977.20 40 14.68 1885 1107 1.41 / 3.32 5 6
5 13 94.56 20 14.92 507 151 1.57 / 3.47 4 8
6 8 -0.04 285 14.88 355 1505 3.07 / 4.98 5 136
Average= 2.49
(KJ/cycle)

Cycle 0 GMT 19/ 4/2024 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 87.24 30 15.20 445 203 0.20 / 0.20 5 5
2 7 101.12 40 15.18 450 273 0.48 / 0.48 5 5
3 13 55.60 20 15.17 384 117 0.59 / 0.59 5 5
4 8 0.20 291 15.12 298 1311 1.90 / 1.90 5 134
Average= 1.90