SIO Argo Site:
Pump Diagnostics Page   



Serial= 7825 WMO= 2903149

Return

←PreviousNext→

Cycle 37 GMT 15/11/2024 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 24 14.80 385 137 0.14 / 135.06 6 6
2 7 2007.24 40 14.36 2641 1517 1.65 / 136.58 6 10
3 13 1304.60 20 14.46 1856 537 2.19 / 137.12 6 15
4 13 607.92 20 14.66 1016 298 2.49 / 137.41 6 16
5 13 141.80 20 14.80 447 132 2.62 / 137.55 6 14
6 13 37.76 20 14.84 314 93 2.71 / 137.64 6 13
7 8 0.12 280 14.80 262 1086 3.80 / 138.73 6 144
Average= 3.65
(KJ/cycle)

Cycle 36 GMT 4/11/2024 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 24 14.81 392 139 0.14 / 131.26 6 6
2 7 2009.04 40 14.35 2670 1533 1.67 / 132.80 6 10
3 13 1319.40 20 14.46 1877 543 2.21 / 133.34 6 16
4 13 625.48 20 14.65 1042 305 2.52 / 133.64 6 16
5 13 148.92 20 14.80 453 134 2.65 / 133.78 6 15
6 13 44.44 20 14.84 316 94 2.75 / 133.87 6 12
7 8 0.08 278 14.81 256 1054 3.80 / 134.93 6 138
Average= 3.65
(KJ/cycle)

Cycle 35 GMT 25/10/2024 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 24 14.80 403 143 0.14 / 127.52 6 6
2 7 2005.60 40 14.37 2637 1516 1.66 / 129.04 6 10
3 13 1288.88 20 14.49 1818 527 2.19 / 129.57 6 16
4 13 568.96 20 14.68 961 282 2.47 / 129.85 6 16
5 13 143.36 20 14.81 453 134 2.60 / 129.98 6 14
6 13 19.96 20 14.86 287 85 2.69 / 130.07 6 11
7 8 0.12 278 14.82 256 1055 3.74 / 131.12 6 134
Average= 3.64
(KJ/cycle)

Cycle 34 GMT 15/10/2024 7:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 24 14.81 395 140 0.14 / 123.65 6 6
2 7 2009.36 40 14.38 2642 1520 1.66 / 125.17 6 10
3 13 1411.96 20 14.46 1954 565 2.23 / 125.74 6 15
4 13 684.72 20 14.65 1106 324 2.55 / 126.06 6 17
5 13 195.52 20 14.79 518 153 2.70 / 126.21 6 16
6 13 26.80 20 14.86 298 89 2.79 / 126.30 6 12
7 8 0.08 280 14.82 260 1079 3.87 / 127.38 6 141
Average= 3.64
(KJ/cycle)

Cycle 33 GMT 5/10/2024 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 24 14.81 394 140 0.14 / 119.84 6 6
2 7 2009.80 40 14.38 2647 1523 1.66 / 121.37 6 10
3 13 1320.56 20 14.49 1846 535 2.20 / 121.90 6 15
4 13 607.12 20 14.67 1020 299 2.50 / 122.20 6 17
5 13 143.00 20 14.82 453 134 2.63 / 122.33 6 14
6 13 39.12 20 14.86 317 94 2.73 / 122.43 6 12
7 8 0.08 278 14.82 263 1084 3.81 / 123.51 6 134
Average= 3.63
(KJ/cycle)

Cycle 32 GMT 24/ 9/2024 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 23 14.81 399 136 0.14 / 116.03 6 6
2 7 2006.48 40 14.39 2642 1521 1.66 / 117.55 6 9
3 13 1304.08 20 14.50 1841 534 2.19 / 118.08 6 15
4 13 612.32 20 14.69 1017 299 2.49 / 118.38 6 16
5 13 149.60 20 14.83 461 137 2.63 / 118.52 6 14
6 13 40.72 20 14.86 321 95 2.72 / 118.61 6 12
7 8 0.12 278 14.82 265 1092 3.81 / 119.70 6 135
Average= 3.63
(KJ/cycle)

Cycle 31 GMT 14/ 9/2024 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 24 14.81 412 146 0.15 / 112.21 6 6
2 7 2007.20 40 14.39 2642 1521 1.67 / 113.73 6 11
3 13 1219.00 20 14.52 1767 513 2.18 / 114.24 6 16
4 13 648.20 20 14.67 1081 317 2.50 / 114.56 6 16
5 13 148.56 20 14.83 469 139 2.64 / 114.70 6 15
6 13 33.40 20 14.86 319 95 2.73 / 114.79 6 13
7 8 0.04 278 14.82 266 1096 3.83 / 115.89 6 140
Average= 3.62
(KJ/cycle)

Cycle 30 GMT 4/ 9/2024 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 23 14.82 394 134 0.13 / 108.34 6 6
2 7 2009.00 41 14.39 2640 1558 1.69 / 109.90 6 10
3 13 1313.84 20 14.50 1866 541 2.23 / 110.44 6 15
4 13 619.12 20 14.68 1043 306 2.54 / 110.75 6 16
5 13 150.00 20 14.83 464 138 2.68 / 110.88 6 14
6 13 40.64 20 14.87 321 95 2.77 / 110.98 6 13
7 8 0.04 278 14.83 263 1084 3.86 / 112.06 6 143
Average= 3.61
(KJ/cycle)

Cycle 29 GMT 24/ 8/2024 22:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 23 14.82 396 135 0.13 / 104.55 6 6
2 3 1025.44 1 14.84 1523 23 0.16 / 104.58 6 7
3 7 2004.72 40 14.40 2644 1523 1.68 / 106.10 7 11
4 13 1229.24 20 14.53 1762 512 2.19 / 106.61 6 16
5 13 560.40 20 14.71 968 285 2.48 / 106.90 6 15
6 13 128.04 20 14.84 429 127 2.60 / 107.02 6 14
7 13 69.76 20 14.86 352 105 2.71 / 107.13 6 12
8 8 0.08 278 14.84 261 1077 3.79 / 108.21 6 138
Average= 3.61
(KJ/cycle)

Cycle 28 GMT 14/ 8/2024 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 23 14.84 385 131 0.13 / 100.70 6 6
2 7 2004.60 40 14.40 2667 1536 1.67 / 102.24 6 10
3 13 1399.96 20 14.49 1974 572 2.24 / 102.81 6 15
4 13 562.00 20 14.72 970 286 2.53 / 103.10 6 16
5 13 146.00 20 14.85 454 135 2.66 / 103.23 6 13
6 13 78.28 20 14.87 366 109 2.77 / 103.34 6 12
7 8 0.08 278 14.85 261 1077 3.85 / 104.42 6 135
Average= 3.60
(KJ/cycle)

Cycle 27 GMT 4/ 8/2024 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 24 14.85 379 135 0.14 / 96.89 6 6
2 3 940.16 -1 15.26 16 0 0.00 / 96.89 6 6
3 7 2002.92 40 14.40 2658 1531 1.67 / 98.42 6 10
4 13 1300.52 20 14.51 1864 541 2.21 / 98.96 6 15
5 13 595.00 20 14.70 1018 299 2.51 / 99.26 6 16
6 13 157.88 20 14.84 468 139 2.65 / 99.40 6 14
7 13 43.16 20 14.88 320 95 2.74 / 99.50 6 11
8 8 0.16 278 14.85 261 1077 3.82 / 100.57 6 143
Average= 3.59
(KJ/cycle)

Cycle 26 GMT 25/ 7/2024 2:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 25 14.85 389 144 0.14 / 93.07 6 6
2 3 953.48 -1 15.27 15 0 0.00 / 93.07 6 6
3 7 2004.56 41 14.40 2650 1565 1.71 / 94.64 6 10
4 13 1301.08 20 14.51 1860 540 2.25 / 95.18 6 15
5 13 593.84 20 14.71 1009 297 2.55 / 95.47 6 16
6 13 145.96 20 14.86 456 136 2.68 / 95.61 6 14
7 8 0.16 297 14.86 260 1147 3.83 / 96.76 6 150
Average= 3.58
(KJ/cycle)

Cycle 25 GMT 14/ 7/2024 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 24 14.85 404 144 0.14 / 89.27 6 6
2 7 2008.68 40 14.40 2656 1530 1.67 / 90.80 6 10
3 13 1308.56 20 14.52 1856 539 2.21 / 91.34 6 15
4 13 601.56 20 14.71 1018 299 2.51 / 91.64 6 16
5 13 135.76 20 14.86 439 130 2.64 / 91.77 6 14
6 13 14.32 20 14.90 283 84 2.73 / 91.85 6 12
7 8 0.08 276 14.85 262 1074 3.80 / 92.93 6 138
Average= 3.57
(KJ/cycle)

Cycle 24 GMT 4/ 7/2024 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 24 14.86 410 146 0.15 / 85.35 6 6
2 7 2008.44 40 14.40 2660 1532 1.68 / 86.89 6 10
3 13 1410.84 20 14.50 1987 576 2.25 / 87.46 6 15
4 13 673.88 20 14.69 1103 324 2.58 / 87.79 6 18
5 13 126.36 20 14.87 431 128 2.71 / 87.91 6 14
6 13 69.12 20 14.88 364 108 2.82 / 88.02 6 14
7 8 0.20 278 14.86 267 1103 3.92 / 89.13 6 151
Average= 3.57
(KJ/cycle)

Cycle 23 GMT 24/ 6/2024 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 25 14.86 398 148 0.15 / 81.57 6 6
2 7 2009.32 40 14.41 2673 1541 1.69 / 83.11 6 11
3 13 1202.88 20 14.56 1745 508 2.20 / 83.62 6 16
4 13 531.44 20 14.75 937 276 2.47 / 83.89 6 16
5 13 114.52 20 14.88 419 125 2.60 / 84.02 6 14
6 13 60.32 20 14.89 349 104 2.70 / 84.12 6 13
7 8 -0.08 276 14.86 265 1087 3.79 / 85.21 6 138
Average= 3.55
(KJ/cycle)

Cycle 22 GMT 13/ 6/2024 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 24 14.86 409 146 0.15 / 77.71 6 6
2 7 2003.92 40 14.41 2670 1539 1.68 / 79.25 6 10
3 13 1298.48 20 14.54 1856 540 2.22 / 79.79 6 15
4 13 601.48 20 14.73 1020 300 2.53 / 80.09 6 16
5 13 143.12 20 14.87 457 136 2.66 / 80.23 6 14
6 13 50.72 20 14.90 337 100 2.76 / 80.33 6 12
7 8 0.04 278 14.87 264 1091 3.85 / 81.42 6 141
Average= 3.54
(KJ/cycle)

Cycle 21 GMT 3/ 6/2024 17: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 24 14.87 397 142 0.14 / 73.86 6 6
2 7 2004.56 40 14.42 2666 1538 1.68 / 75.40 6 10
3 13 1292.56 20 14.54 1851 538 2.22 / 75.94 6 15
4 13 577.88 20 14.74 997 294 2.51 / 76.23 6 16
5 13 130.96 20 14.88 444 132 2.64 / 76.37 6 14
6 13 68.44 20 14.89 363 108 2.75 / 76.47 6 13
7 8 0.16 278 14.87 264 1091 3.84 / 77.57 6 148
Average= 3.53
(KJ/cycle)

Cycle 20 GMT 24/ 5/2024 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 24 14.86 412 147 0.15 / 70.03 6 6
2 7 2003.64 40 14.43 2647 1528 1.67 / 71.56 6 10
3 13 1301.48 20 14.55 1861 542 2.22 / 72.10 6 15
4 13 603.40 20 14.74 1020 301 2.52 / 72.40 6 15
5 13 139.56 20 14.88 455 135 2.65 / 72.54 6 14
6 13 40.04 20 14.91 321 96 2.75 / 72.63 6 13
7 8 0.12 278 14.88 264 1092 3.84 / 73.72 6 136
Average= 3.51
(KJ/cycle)

Cycle 19 GMT 14/ 5/2024 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 24 14.86 412 147 0.15 / 66.18 6 6
2 7 2004.32 40 14.43 2668 1540 1.69 / 67.72 6 9
3 13 1293.36 20 14.55 1851 539 2.23 / 68.26 6 16
4 13 594.56 20 14.74 1011 298 2.52 / 68.56 6 16
5 13 123.68 20 14.89 434 129 2.65 / 68.69 6 14
6 13 35.48 20 14.92 316 94 2.75 / 68.78 6 13
7 8 0.12 278 14.88 266 1100 3.85 / 69.88 6 134
Average= 3.49
(KJ/cycle)

Cycle 18 GMT 3/ 5/2024 21:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 24 14.88 401 143 0.14 / 62.30 6 6
2 7 2002.56 40 14.43 2648 1528 1.67 / 63.83 6 9
3 13 1295.92 20 14.55 1860 541 2.21 / 64.37 6 16
4 13 599.68 20 14.74 1022 301 2.51 / 64.67 6 15
5 13 130.72 20 14.88 444 132 2.65 / 64.81 6 15
6 13 28.44 20 14.92 308 92 2.74 / 64.90 6 13
7 8 0.08 278 14.88 275 1138 3.88 / 66.04 6 144
Average= 3.48
(KJ/cycle)

Cycle 17 GMT 23/ 4/2024 14:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 24 14.88 392 140 0.14 / 58.43 6 6
2 7 2004.72 40 14.43 2672 1542 1.68 / 59.97 6 9
3 13 1295.52 20 14.56 1847 538 2.22 / 60.51 6 14
4 13 692.76 20 14.71 1132 333 2.55 / 60.84 6 16
5 13 102.96 20 14.90 407 121 2.67 / 60.96 6 13
6 13 16.36 20 14.93 295 88 2.76 / 61.05 6 12
7 8 0.12 278 14.89 268 1109 3.87 / 62.16 6 147
Average= 3.45
(KJ/cycle)

Cycle 16 GMT 13/ 4/2024 8: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 23 14.88 399 137 0.14 / 54.59 6 6
2 3 1041.12 1 14.86 1536 23 0.16 / 54.61 6 9
3 7 2004.56 40 14.45 2634 1522 1.68 / 56.13 9 10
4 13 1285.16 20 14.57 1830 533 2.22 / 56.67 6 14
5 13 588.32 20 14.76 1011 298 2.51 / 56.97 6 15
6 13 128.64 20 14.90 433 129 2.64 / 57.09 6 14
7 13 31.64 20 14.93 308 92 2.73 / 57.19 6 13
8 8 0.04 278 14.89 266 1101 3.84 / 58.29 6 136
Average= 3.43
(KJ/cycle)

Cycle 15 GMT 3/ 4/2024 1:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 24 14.87 390 139 0.14 / 50.76 6 6
2 3 952.28 -1 15.30 16 0 0.00 / 50.76 6 6
3 7 2012.96 40 14.45 2662 1539 1.68 / 52.29 6 10
4 13 1210.56 20 14.59 1757 513 2.19 / 52.81 6 15
5 13 629.32 20 14.75 1049 309 2.50 / 53.12 6 16
6 13 144.72 20 14.89 464 138 2.64 / 53.26 6 15
7 13 36.88 20 14.93 321 96 2.73 / 53.35 6 13
8 8 0.08 278 14.89 266 1101 3.84 / 54.45 6 140
Average= 3.40
(KJ/cycle)

Cycle 14 GMT 23/ 3/2024 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 24 14.88 402 144 0.14 / 46.82 6 6
2 7 2008.92 41 14.45 2652 1571 1.71 / 48.39 6 10
3 13 1394.92 20 14.55 1968 573 2.29 / 48.96 6 14
4 13 639.36 20 14.75 1068 315 2.60 / 49.27 6 17
5 13 132.96 20 14.89 452 135 2.74 / 49.41 6 15
6 8 0.04 297 14.90 273 1208 3.95 / 50.62 6 143
Average= 3.37
(KJ/cycle)

Cycle 13 GMT 13/ 3/2024 12:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 24 14.88 405 145 0.14 / 42.90 6 6
2 7 2007.08 40 14.44 2659 1536 1.68 / 44.43 6 10
3 13 1300.16 20 14.57 1862 543 2.22 / 44.98 6 16
4 13 807.24 20 14.69 1275 375 2.60 / 45.35 6 17
5 13 92.24 20 14.92 389 116 2.71 / 45.47 6 14
6 13 23.76 20 14.95 301 90 2.80 / 45.56 6 13
7 8 0.04 276 14.90 271 1114 3.92 / 46.67 6 133
Average= 3.33
(KJ/cycle)

Cycle 12 GMT 3/ 3/2024 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 24 14.89 394 141 0.14 / 39.03 6 6
2 7 2006.64 40 14.45 2655 1535 1.68 / 40.56 6 10
3 13 1392.08 20 14.55 1965 572 2.25 / 41.13 6 14
4 13 545.32 20 14.79 945 280 2.53 / 41.41 6 16
5 13 94.60 20 14.92 396 118 2.64 / 41.53 6 14
6 13 53.56 20 14.93 344 103 2.75 / 41.64 6 14
7 8 0.04 278 14.90 270 1118 3.87 / 42.75 6 158
Average= 3.29
(KJ/cycle)

Cycle 11 GMT 21/ 2/2024 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 24 14.90 395 141 0.14 / 35.16 6 6
2 7 2002.40 40 14.46 2665 1541 1.68 / 36.71 6 9
3 13 1391.36 20 14.57 1953 569 2.25 / 37.27 6 14
4 13 554.04 20 14.79 949 281 2.53 / 37.56 6 16
5 13 110.16 20 14.93 412 123 2.66 / 37.68 6 14
6 8 0.12 297 14.91 273 1209 3.86 / 38.89 6 140
Average= 3.24
(KJ/cycle)

Cycle 10 GMT 11/ 2/2024 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 24 14.89 413 148 0.15 / 31.36 6 6
2 7 2004.52 40 14.47 2638 1527 1.67 / 32.89 6 10
3 13 1211.64 20 14.62 1723 504 2.18 / 33.39 6 15
4 13 638.04 20 14.77 1029 304 2.48 / 33.69 6 16
5 13 150.08 20 14.92 435 130 2.61 / 33.82 6 15
6 13 15.16 20 14.96 295 88 2.70 / 33.91 6 13
7 8 0.08 278 14.91 268 1111 3.81 / 35.02 6 146
Average= 3.18
(KJ/cycle)

Cycle 9 GMT 1/ 2/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 24 14.90 433 155 0.15 / 27.53 6 6
2 7 2009.08 40 14.47 2648 1533 1.69 / 29.06 6 10
3 13 1212.04 20 14.62 1723 504 2.19 / 29.56 6 15
4 13 533.44 20 14.80 930 275 2.47 / 29.84 6 16
5 13 99.92 20 14.93 413 123 2.59 / 29.96 6 14
6 13 27.48 20 14.95 314 94 2.68 / 30.06 6 13
7 8 0.00 278 14.91 279 1156 3.84 / 31.21 6 140
Average= 3.12
(KJ/cycle)

Cycle 8 GMT 22/ 1/2024 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 24 14.91 403 144 0.14 / 23.67 6 6
2 7 2004.52 40 14.47 2635 1525 1.67 / 25.19 6 10
3 13 1285.52 20 14.61 1802 527 2.20 / 25.72 6 14
4 13 671.00 20 14.77 1070 316 2.51 / 26.03 6 17
5 13 93.88 20 14.94 401 120 2.63 / 26.15 6 14
6 13 32.96 20 14.95 325 97 2.73 / 26.25 6 13
7 8 0.12 278 14.92 270 1120 3.85 / 27.37 6 150
Average= 3.04
(KJ/cycle)

Cycle 7 GMT 11/ 1/2024 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 24 14.94 349 125 0.13 / 19.96 6 6
2 7 2008.76 40 14.47 2636 1526 1.65 / 21.49 6 10
3 13 1242.20 20 14.62 1758 514 2.16 / 22.00 6 16
4 13 547.36 20 14.81 915 271 2.44 / 22.27 6 16
5 13 104.32 20 14.95 368 110 2.55 / 22.38 6 14
6 13 25.24 20 14.98 264 79 2.63 / 22.46 6 13
7 8 0.00 276 14.93 258 1063 3.69 / 23.52 6 134
Average= 2.94
(KJ/cycle)

Cycle 6 GMT 1/ 1/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 21 14.94 362 114 0.11 / 16.26 6 6
2 10 1021.68 4 14.87 1460 87 0.20 / 16.35 6 7
3 7 2006.96 40 14.47 2645 1531 1.73 / 17.88 7 10
4 13 1295.80 20 14.61 1818 531 2.26 / 18.41 6 16
5 13 694.68 20 14.77 1093 323 2.59 / 18.73 6 17
6 13 109.00 20 14.95 374 112 2.70 / 18.84 6 14
7 8 0.08 297 14.96 223 991 3.69 / 19.83 6 147
Average= 2.83
(KJ/cycle)

Cycle 5 GMT 22/12/2023 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 31 14.95 355 165 0.16 / 12.76 6 6
2 3 695.72 -5 15.33 16 0 0.00 / 12.76 6 6
3 7 2003.80 40 14.49 2635 1527 1.69 / 14.29 6 10
4 13 1209.80 20 14.65 1712 502 2.19 / 14.79 6 16
5 13 513.60 20 14.83 878 260 2.45 / 15.05 6 16
6 13 100.52 20 14.96 363 109 2.56 / 15.16 6 14
7 8 0.16 293 14.96 225 986 3.55 / 16.15 6 131
Average= 2.69
(KJ/cycle)

Cycle 4 GMT 12/12/2023 0: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 24 14.95 362 130 0.13 / 9.62 6 6
2 7 1511.96 40 14.70 2060 1211 1.34 / 10.83 6 11
3 13 1096.08 20 14.74 1573 464 1.80 / 11.29 6 13
4 13 409.32 20 14.90 750 223 2.03 / 11.51 6 15
5 13 86.36 20 14.99 345 103 2.13 / 11.62 6 14
6 8 0.04 291 14.98 225 981 3.11 / 12.60 6 147
Average= 2.52
(KJ/cycle)

Cycle 3 GMT 10/12/2023 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 22 14.96 359 118 0.12 / 6.41 6 6
2 10 1006.24 3 14.87 1465 65 0.18 / 6.48 6 7
3 7 1517.48 40 14.71 2055 1209 1.39 / 7.69 6 10
4 13 1079.20 20 14.74 1562 460 1.85 / 8.15 6 14
5 13 476.76 20 14.88 830 247 2.10 / 8.39 6 15
6 13 117.84 20 14.98 385 115 2.22 / 8.51 6 15
7 8 0.12 291 14.98 224 976 3.19 / 9.49 6 152
Average= 2.37
(KJ/cycle)

Cycle 2 GMT 9/12/2023 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 14.98 348 162 0.16 / 3.32 6 6
2 3 716.20 -4 15.33 15 0 0.00 / 3.32 6 6
3 7 1510.40 40 14.70 2068 1216 1.38 / 4.54 6 11
4 13 1176.48 20 14.72 1665 490 1.87 / 5.03 6 12
5 13 339.96 20 14.91 657 196 2.06 / 5.22 6 14
6 13 72.80 20 14.99 324 97 2.16 / 5.32 6 13
7 8 0.12 291 14.98 223 972 3.13 / 6.29 6 150
Average= 2.10
(KJ/cycle)

Cycle 1 GMT 7/12/2023 18:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 31 15.18 331 156 0.16 / 1.35 6 7
2 3 727.24 -4 15.35 16 0 0.00 / 1.35 6 7
3 7 811.64 40 14.93 1218 727 0.88 / 2.08 7 12
4 13 93.88 20 15.06 351 106 0.99 / 2.18 6 12
5 13 24.76 20 15.07 257 77 1.07 / 2.26 6 11
6 8 0.08 274 15.04 218 898 1.96 / 3.16 6 146
Average= 1.58
(KJ/cycle)

Cycle 0 GMT 7/12/2023 8:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.40 30 15.32 283 130 0.13 / 0.13 6 7
2 7 84.56 40 15.29 293 179 0.31 / 0.31 7 7
3 13 58.84 20 15.27 266 81 0.39 / 0.39 6 7
4 8 0.04 287 15.25 184 805 1.20 / 1.20 6 142
Average= 1.20
(KJ/cycle)