SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 30 | 14.83 | 432 | 192 | 0.19 / 157.73 | 5 | 6 |
2 | 7 | 2003.04 | 40 | 14.36 | 3031 | 1741 | 1.93 / 159.48 | 6 | 22 |
3 | 13 | 1320.88 | 20 | 14.46 | 2153 | 623 | 2.56 / 160.10 | 5 | 32 |
4 | 13 | 763.24 | 20 | 14.61 | 1420 | 415 | 2.97 / 160.51 | 5 | 36 |
5 | 13 | 176.48 | 20 | 14.81 | 581 | 172 | 3.14 / 160.69 | 5 | 33 |
6 | 13 | 100.80 | 20 | 14.84 | 461 | 137 | 3.28 / 160.82 | 5 | 31 |
7 | 8 | 0.20 | 272 | 14.83 | 295 | 1190 | 4.47 / 162.01 | 5 | 140 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 29 | 14.83 | 438 | 188 | 0.19 / 153.28 | 5 | 6 |
2 | 7 | 2011.24 | 40 | 14.36 | 3024 | 1737 | 1.93 / 155.02 | 6 | 23 |
3 | 13 | 1312.08 | 20 | 14.46 | 2155 | 623 | 2.55 / 155.64 | 5 | 32 |
4 | 13 | 753.64 | 20 | 14.61 | 1406 | 411 | 2.96 / 156.06 | 5 | 36 |
5 | 13 | 159.68 | 20 | 14.82 | 549 | 163 | 3.12 / 156.22 | 5 | 32 |
6 | 13 | 85.24 | 20 | 14.85 | 436 | 129 | 3.25 / 156.35 | 5 | 32 |
7 | 8 | 0.08 | 272 | 14.84 | 296 | 1195 | 4.45 / 157.54 | 5 | 140 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 29 | 14.84 | 431 | 185 | 0.19 / 148.74 | 5 | 6 |
2 | 7 | 2005.72 | 40 | 14.37 | 3004 | 1727 | 1.91 / 150.46 | 6 | 21 |
3 | 13 | 1421.80 | 20 | 14.44 | 2301 | 665 | 2.58 / 151.13 | 5 | 30 |
4 | 13 | 822.00 | 20 | 14.59 | 1501 | 438 | 3.01 / 151.57 | 5 | 36 |
5 | 13 | 200.72 | 20 | 14.81 | 613 | 182 | 3.20 / 151.75 | 5 | 35 |
6 | 13 | 89.76 | 20 | 14.86 | 437 | 130 | 3.33 / 151.88 | 5 | 30 |
7 | 13 | 48.16 | 20 | 14.87 | 372 | 111 | 3.44 / 151.99 | 5 | 30 |
8 | 8 | 0.12 | 253 | 14.84 | 295 | 1108 | 4.54 / 153.10 | 5 | 149 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 14.84 | 430 | 185 | 0.19 / 144.32 | 5 | 6 |
2 | 7 | 2012.32 | 40 | 14.37 | 3005 | 1727 | 1.91 / 146.05 | 6 | 23 |
3 | 13 | 1414.04 | 20 | 14.45 | 2278 | 658 | 2.57 / 146.71 | 5 | 30 |
4 | 13 | 690.40 | 20 | 14.65 | 1308 | 383 | 2.95 / 147.09 | 5 | 36 |
5 | 13 | 141.08 | 20 | 14.84 | 517 | 153 | 3.11 / 147.24 | 5 | 32 |
6 | 13 | 88.00 | 20 | 14.86 | 435 | 129 | 3.24 / 147.37 | 5 | 31 |
7 | 8 | 0.08 | 270 | 14.85 | 294 | 1179 | 4.42 / 148.55 | 5 | 134 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 14.84 | 437 | 188 | 0.19 / 139.90 | 5 | 6 |
2 | 7 | 2010.64 | 40 | 14.36 | 3010 | 1729 | 1.92 / 141.63 | 6 | 22 |
3 | 13 | 1320.64 | 20 | 14.47 | 2155 | 624 | 2.54 / 142.26 | 5 | 31 |
4 | 13 | 744.40 | 20 | 14.62 | 1384 | 405 | 2.95 / 142.66 | 5 | 36 |
5 | 13 | 152.44 | 20 | 14.83 | 540 | 160 | 3.11 / 142.82 | 5 | 34 |
6 | 13 | 93.08 | 20 | 14.85 | 448 | 133 | 3.24 / 142.95 | 5 | 33 |
7 | 8 | 0.08 | 270 | 14.85 | 295 | 1183 | 4.42 / 144.14 | 5 | 135 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.85 | 435 | 187 | 0.19 / 135.46 | 5 | 6 |
2 | 7 | 2013.32 | 40 | 14.37 | 3008 | 1729 | 1.92 / 137.19 | 6 | 22 |
3 | 13 | 1407.60 | 20 | 14.46 | 2256 | 652 | 2.57 / 137.84 | 5 | 32 |
4 | 13 | 712.12 | 20 | 14.64 | 1343 | 393 | 2.96 / 138.23 | 5 | 36 |
5 | 13 | 147.28 | 20 | 14.84 | 528 | 157 | 3.12 / 138.39 | 5 | 33 |
6 | 13 | 91.16 | 20 | 14.86 | 445 | 132 | 3.25 / 138.52 | 5 | 33 |
7 | 8 | 0.04 | 272 | 14.85 | 295 | 1192 | 4.44 / 139.71 | 5 | 145 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 29 | 14.86 | 427 | 184 | 0.18 / 131.05 | 5 | 6 |
2 | 7 | 2003.12 | 40 | 14.37 | 3003 | 1726 | 1.91 / 132.77 | 6 | 23 |
3 | 13 | 1315.16 | 20 | 14.49 | 2142 | 621 | 2.53 / 133.39 | 5 | 32 |
4 | 13 | 734.52 | 20 | 14.63 | 1376 | 403 | 2.93 / 133.80 | 5 | 37 |
5 | 13 | 150.72 | 20 | 14.84 | 535 | 159 | 3.09 / 133.96 | 5 | 33 |
6 | 13 | 101.36 | 20 | 14.85 | 461 | 137 | 3.23 / 134.09 | 5 | 31 |
7 | 13 | 25.72 | 20 | 14.89 | 335 | 100 | 3.33 / 134.19 | 5 | 30 |
8 | 8 | 0.00 | 250 | 14.85 | 291 | 1080 | 4.41 / 135.27 | 5 | 132 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 14.85 | 435 | 187 | 0.19 / 126.65 | 5 | 6 |
2 | 7 | 2005.92 | 40 | 14.37 | 2990 | 1719 | 1.91 / 128.36 | 6 | 23 |
3 | 13 | 1398.40 | 20 | 14.47 | 2239 | 648 | 2.55 / 129.01 | 5 | 30 |
4 | 13 | 699.04 | 20 | 14.65 | 1324 | 388 | 2.94 / 129.40 | 5 | 36 |
5 | 13 | 138.32 | 20 | 14.85 | 517 | 154 | 3.10 / 129.55 | 5 | 32 |
6 | 13 | 86.32 | 20 | 14.87 | 434 | 129 | 3.22 / 129.68 | 5 | 31 |
7 | 8 | 0.16 | 270 | 14.86 | 294 | 1180 | 4.40 / 130.86 | 5 | 135 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 29 | 14.86 | 430 | 185 | 0.19 / 122.28 | 5 | 6 |
2 | 7 | 2003.72 | 40 | 14.39 | 3001 | 1727 | 1.91 / 124.01 | 6 | 22 |
3 | 13 | 1207.68 | 20 | 14.52 | 2010 | 584 | 2.50 / 124.60 | 5 | 32 |
4 | 13 | 656.32 | 20 | 14.67 | 1268 | 372 | 2.87 / 124.97 | 5 | 35 |
5 | 13 | 165.24 | 20 | 14.84 | 558 | 166 | 3.03 / 125.13 | 5 | 34 |
6 | 13 | 90.68 | 20 | 14.87 | 441 | 131 | 3.17 / 125.26 | 5 | 33 |
7 | 8 | 0.12 | 270 | 14.85 | 298 | 1195 | 4.36 / 126.46 | 5 | 138 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 14.85 | 446 | 192 | 0.19 / 117.89 | 5 | 6 |
2 | 7 | 2003.44 | 40 | 14.39 | 2986 | 1719 | 1.91 / 119.61 | 6 | 22 |
3 | 13 | 1300.24 | 20 | 14.50 | 2142 | 621 | 2.53 / 120.23 | 5 | 32 |
4 | 13 | 718.12 | 20 | 14.65 | 1358 | 398 | 2.93 / 120.62 | 5 | 36 |
5 | 13 | 133.60 | 20 | 14.86 | 512 | 152 | 3.08 / 120.78 | 5 | 33 |
6 | 13 | 77.00 | 20 | 14.88 | 424 | 126 | 3.21 / 120.90 | 5 | 32 |
7 | 8 | 0.12 | 270 | 14.86 | 298 | 1196 | 4.40 / 122.10 | 5 | 132 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 29 | 14.85 | 438 | 189 | 0.19 / 113.44 | 5 | 6 |
2 | 7 | 2005.84 | 40 | 14.39 | 3012 | 1734 | 1.92 / 115.17 | 6 | 22 |
3 | 13 | 1320.76 | 20 | 14.50 | 2173 | 630 | 2.55 / 115.80 | 5 | 31 |
4 | 13 | 749.80 | 20 | 14.65 | 1395 | 409 | 2.96 / 116.21 | 5 | 36 |
5 | 13 | 149.68 | 20 | 14.85 | 536 | 159 | 3.12 / 116.37 | 5 | 33 |
6 | 13 | 71.80 | 20 | 14.88 | 414 | 123 | 3.24 / 116.49 | 5 | 31 |
7 | 8 | 0.04 | 272 | 14.87 | 297 | 1201 | 4.44 / 117.69 | 5 | 143 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 29 | 14.85 | 450 | 194 | 0.19 / 108.88 | 5 | 6 |
2 | 7 | 2005.44 | 40 | 14.39 | 3017 | 1737 | 1.93 / 110.62 | 6 | 22 |
3 | 13 | 1411.16 | 20 | 14.49 | 2275 | 659 | 2.59 / 111.28 | 5 | 30 |
4 | 13 | 819.92 | 20 | 14.62 | 1501 | 439 | 3.03 / 111.71 | 5 | 36 |
5 | 13 | 190.92 | 20 | 14.83 | 600 | 178 | 3.21 / 111.89 | 5 | 35 |
6 | 13 | 67.00 | 20 | 14.88 | 411 | 122 | 3.33 / 112.02 | 5 | 33 |
7 | 13 | 38.92 | 20 | 14.89 | 367 | 109 | 3.44 / 112.12 | 5 | 33 |
8 | 8 | 0.04 | 250 | 14.86 | 303 | 1126 | 4.56 / 113.25 | 5 | 130 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 29 | 14.86 | 427 | 184 | 0.18 / 104.44 | 5 | 6 |
2 | 7 | 2011.68 | 40 | 14.40 | 3026 | 1743 | 1.93 / 106.18 | 6 | 22 |
3 | 13 | 1314.76 | 20 | 14.51 | 2144 | 622 | 2.55 / 106.81 | 5 | 31 |
4 | 13 | 637.12 | 20 | 14.69 | 1249 | 367 | 2.92 / 107.17 | 5 | 35 |
5 | 13 | 155.00 | 20 | 14.85 | 552 | 164 | 3.08 / 107.34 | 5 | 35 |
6 | 13 | 64.88 | 20 | 14.89 | 410 | 122 | 3.20 / 107.46 | 5 | 32 |
7 | 13 | 40.40 | 20 | 14.89 | 370 | 110 | 3.31 / 107.57 | 5 | 33 |
8 | 8 | 0.04 | 248 | 14.86 | 303 | 1117 | 4.43 / 108.69 | 5 | 131 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 14.86 | 439 | 189 | 0.19 / 99.99 | 5 | 6 |
2 | 7 | 2003.72 | 40 | 14.41 | 3000 | 1729 | 1.92 / 101.72 | 6 | 22 |
3 | 13 | 1384.84 | 20 | 14.50 | 2243 | 650 | 2.57 / 102.37 | 5 | 31 |
4 | 13 | 682.20 | 20 | 14.68 | 1306 | 383 | 2.95 / 102.75 | 5 | 36 |
5 | 13 | 115.24 | 20 | 14.87 | 495 | 147 | 3.10 / 102.90 | 5 | 33 |
6 | 13 | 60.52 | 20 | 14.89 | 411 | 122 | 3.22 / 103.02 | 5 | 34 |
7 | 13 | 36.76 | 20 | 14.89 | 372 | 111 | 3.33 / 103.13 | 5 | 34 |
8 | 8 | 0.00 | 248 | 14.86 | 305 | 1124 | 4.46 / 104.26 | 5 | 140 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 29 | 14.87 | 435 | 188 | 0.19 / 95.60 | 5 | 6 |
2 | 7 | 2006.24 | 40 | 14.40 | 3007 | 1732 | 1.92 / 97.33 | 6 | 21 |
3 | 13 | 1309.32 | 20 | 14.51 | 2149 | 624 | 2.54 / 97.96 | 5 | 32 |
4 | 13 | 631.40 | 20 | 14.70 | 1237 | 364 | 2.91 / 98.32 | 5 | 36 |
5 | 13 | 97.00 | 20 | 14.89 | 455 | 135 | 3.04 / 98.46 | 5 | 33 |
6 | 13 | 54.08 | 20 | 14.89 | 395 | 118 | 3.16 / 98.57 | 5 | 33 |
7 | 13 | 34.64 | 20 | 14.90 | 364 | 108 | 3.27 / 98.68 | 5 | 34 |
8 | 8 | -0.08 | 246 | 14.86 | 306 | 1119 | 4.39 / 99.80 | 5 | 133 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 29 | 14.87 | 431 | 186 | 0.19 / 91.14 | 5 | 6 |
2 | 7 | 2012.32 | 40 | 14.42 | 3008 | 1735 | 1.92 / 92.87 | 6 | 22 |
3 | 13 | 1306.92 | 20 | 14.52 | 2157 | 626 | 2.55 / 93.50 | 5 | 32 |
4 | 13 | 736.40 | 20 | 14.66 | 1390 | 408 | 2.95 / 93.90 | 5 | 36 |
5 | 13 | 135.72 | 20 | 14.87 | 515 | 153 | 3.11 / 94.06 | 5 | 34 |
6 | 13 | 51.00 | 20 | 14.90 | 386 | 115 | 3.22 / 94.17 | 5 | 33 |
7 | 13 | 34.40 | 20 | 14.90 | 360 | 107 | 3.33 / 94.28 | 5 | 34 |
8 | 8 | 0.00 | 250 | 14.87 | 305 | 1134 | 4.46 / 95.41 | 5 | 136 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 29 | 14.86 | 430 | 185 | 0.19 / 86.70 | 5 | 6 |
2 | 7 | 2004.92 | 40 | 14.40 | 3012 | 1735 | 1.92 / 88.43 | 6 | 22 |
3 | 13 | 1412.96 | 20 | 14.50 | 2274 | 659 | 2.58 / 89.09 | 5 | 30 |
4 | 13 | 693.08 | 20 | 14.69 | 1326 | 390 | 2.97 / 89.48 | 5 | 35 |
5 | 13 | 111.28 | 20 | 14.89 | 478 | 142 | 3.11 / 89.62 | 5 | 34 |
6 | 13 | 49.20 | 20 | 14.91 | 380 | 113 | 3.22 / 89.74 | 5 | 33 |
7 | 13 | 31.88 | 20 | 14.91 | 356 | 106 | 3.33 / 89.84 | 5 | 33 |
8 | 8 | -0.04 | 248 | 14.88 | 300 | 1107 | 4.44 / 90.95 | 5 | 131 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 29 | 14.86 | 447 | 193 | 0.19 / 82.19 | 5 | 6 |
2 | 7 | 2003.52 | 40 | 14.42 | 3001 | 1731 | 1.92 / 83.92 | 6 | 21 |
3 | 13 | 1316.36 | 20 | 14.53 | 2161 | 628 | 2.55 / 84.55 | 5 | 32 |
4 | 13 | 731.76 | 20 | 14.67 | 1374 | 403 | 2.95 / 84.95 | 5 | 36 |
5 | 13 | 241.28 | 20 | 14.83 | 675 | 200 | 3.15 / 85.15 | 5 | 36 |
6 | 13 | 52.12 | 20 | 14.90 | 387 | 115 | 3.27 / 85.27 | 5 | 35 |
7 | 13 | 33.12 | 20 | 14.90 | 363 | 108 | 3.38 / 85.37 | 5 | 36 |
8 | 8 | -0.04 | 250 | 14.86 | 306 | 1137 | 4.52 / 86.51 | 5 | 143 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.88 | 29 | 14.87 | 466 | 201 | 0.20 / 77.68 | 5 | 7 |
2 | 7 | 2012.28 | 40 | 14.42 | 2998 | 1729 | 1.93 / 79.41 | 7 | 21 |
3 | 13 | 1403.20 | 20 | 14.51 | 2276 | 660 | 2.59 / 80.07 | 5 | 30 |
4 | 13 | 776.16 | 20 | 14.66 | 1442 | 423 | 3.01 / 80.49 | 5 | 36 |
5 | 13 | 162.64 | 20 | 14.87 | 558 | 166 | 3.18 / 80.66 | 5 | 35 |
6 | 13 | 37.00 | 20 | 14.91 | 370 | 110 | 3.29 / 80.77 | 5 | 34 |
7 | 8 | -0.04 | 270 | 14.87 | 306 | 1229 | 4.52 / 82.00 | 5 | 144 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 29 | 14.89 | 437 | 189 | 0.19 / 73.24 | 5 | 6 |
2 | 7 | 2013.20 | 40 | 14.41 | 3021 | 1741 | 1.93 / 74.99 | 6 | 22 |
3 | 13 | 1338.36 | 20 | 14.52 | 2189 | 636 | 2.57 / 75.62 | 5 | 32 |
4 | 13 | 667.36 | 20 | 14.70 | 1284 | 377 | 2.94 / 76.00 | 5 | 36 |
5 | 13 | 114.20 | 20 | 14.89 | 485 | 144 | 3.09 / 76.14 | 5 | 34 |
6 | 13 | 46.76 | 20 | 14.91 | 379 | 113 | 3.20 / 76.26 | 5 | 33 |
7 | 8 | 0.08 | 270 | 14.88 | 304 | 1221 | 4.42 / 77.48 | 5 | 137 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 29 | 14.87 | 427 | 184 | 0.18 / 68.88 | 5 | 6 |
2 | 7 | 2009.00 | 40 | 14.43 | 3007 | 1736 | 1.92 / 70.62 | 6 | 23 |
3 | 13 | 1316.48 | 20 | 14.53 | 2159 | 627 | 2.55 / 71.24 | 5 | 32 |
4 | 13 | 630.00 | 20 | 14.71 | 1229 | 362 | 2.91 / 71.61 | 5 | 36 |
5 | 13 | 106.24 | 20 | 14.90 | 465 | 139 | 3.05 / 71.74 | 5 | 33 |
6 | 13 | 40.56 | 20 | 14.92 | 366 | 109 | 3.16 / 71.85 | 5 | 32 |
7 | 8 | 0.00 | 270 | 14.89 | 299 | 1202 | 4.36 / 73.06 | 5 | 146 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 29 | 14.88 | 446 | 192 | 0.19 / 64.35 | 5 | 6 |
2 | 7 | 2014.08 | 40 | 14.43 | 3020 | 1743 | 1.94 / 66.10 | 6 | 21 |
3 | 13 | 1402.96 | 20 | 14.52 | 2279 | 662 | 2.60 / 66.76 | 5 | 31 |
4 | 13 | 791.72 | 20 | 14.66 | 1462 | 429 | 3.03 / 67.19 | 5 | 36 |
5 | 13 | 178.36 | 20 | 14.86 | 585 | 174 | 3.20 / 67.36 | 5 | 36 |
6 | 13 | 46.92 | 20 | 14.92 | 381 | 114 | 3.31 / 67.48 | 5 | 34 |
7 | 8 | -0.08 | 270 | 14.88 | 304 | 1221 | 4.53 / 68.70 | 5 | 139 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 29 | 14.88 | 451 | 195 | 0.19 / 59.88 | 5 | 6 |
2 | 7 | 2004.56 | 41 | 14.42 | 2992 | 1769 | 1.96 / 61.65 | 6 | 22 |
3 | 13 | 1416.64 | 20 | 14.51 | 2288 | 664 | 2.63 / 62.32 | 5 | 31 |
4 | 13 | 600.72 | 20 | 14.73 | 1188 | 350 | 2.98 / 62.67 | 5 | 35 |
5 | 13 | 152.52 | 20 | 14.88 | 541 | 161 | 3.14 / 62.83 | 5 | 34 |
6 | 13 | 37.04 | 20 | 14.92 | 365 | 109 | 3.25 / 62.94 | 5 | 33 |
7 | 8 | 0.00 | 270 | 14.89 | 305 | 1226 | 4.47 / 64.16 | 5 | 141 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 29 | 14.88 | 450 | 194 | 0.19 / 55.43 | 5 | 6 |
2 | 7 | 2004.96 | 40 | 14.44 | 3003 | 1735 | 1.93 / 57.17 | 6 | 22 |
3 | 13 | 1299.52 | 20 | 14.56 | 2131 | 621 | 2.55 / 57.79 | 5 | 31 |
4 | 13 | 717.48 | 20 | 14.69 | 1353 | 398 | 2.95 / 58.19 | 5 | 36 |
5 | 13 | 127.80 | 20 | 14.89 | 505 | 150 | 3.10 / 58.34 | 5 | 34 |
6 | 13 | 36.76 | 20 | 14.93 | 369 | 110 | 3.21 / 58.45 | 5 | 33 |
7 | 8 | 0.08 | 270 | 14.89 | 309 | 1242 | 4.45 / 59.69 | 5 | 138 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 29 | 14.88 | 452 | 195 | 0.20 / 50.93 | 5 | 6 |
2 | 7 | 2005.28 | 40 | 14.43 | 3022 | 1744 | 1.94 / 52.67 | 6 | 21 |
3 | 13 | 1417.80 | 20 | 14.53 | 2282 | 663 | 2.60 / 53.34 | 5 | 30 |
4 | 13 | 714.08 | 20 | 14.70 | 1349 | 397 | 3.00 / 53.73 | 5 | 36 |
5 | 13 | 125.24 | 20 | 14.89 | 514 | 153 | 3.15 / 53.89 | 5 | 34 |
6 | 13 | 33.28 | 20 | 14.93 | 361 | 108 | 3.26 / 54.00 | 5 | 34 |
7 | 8 | -0.08 | 272 | 14.89 | 307 | 1243 | 4.50 / 55.24 | 5 | 151 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 29 | 14.88 | 456 | 197 | 0.20 / 46.50 | 5 | 6 |
2 | 7 | 2008.16 | 40 | 14.45 | 2979 | 1722 | 1.92 / 48.22 | 6 | 22 |
3 | 13 | 1407.60 | 20 | 14.53 | 2265 | 658 | 2.58 / 48.88 | 5 | 31 |
4 | 13 | 607.60 | 20 | 14.74 | 1202 | 354 | 2.93 / 49.23 | 5 | 36 |
5 | 13 | 127.08 | 20 | 14.90 | 502 | 150 | 3.08 / 49.38 | 5 | 35 |
6 | 13 | 26.68 | 20 | 14.93 | 356 | 106 | 3.19 / 49.49 | 5 | 34 |
7 | 8 | -0.04 | 270 | 14.89 | 310 | 1246 | 4.43 / 50.74 | 5 | 144 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 29 | 14.89 | 449 | 194 | 0.19 / 42.00 | 5 | 6 |
2 | 7 | 2011.28 | 40 | 14.45 | 3015 | 1743 | 1.94 / 43.74 | 6 | 23 |
3 | 13 | 1311.24 | 20 | 14.55 | 2159 | 628 | 2.56 / 44.37 | 5 | 31 |
4 | 13 | 740.72 | 20 | 14.69 | 1381 | 406 | 2.97 / 44.77 | 5 | 37 |
5 | 13 | 132.80 | 20 | 14.89 | 518 | 154 | 3.12 / 44.93 | 5 | 36 |
6 | 13 | 29.16 | 20 | 14.93 | 356 | 106 | 3.23 / 45.03 | 5 | 35 |
7 | 8 | -0.08 | 270 | 14.88 | 316 | 1270 | 4.50 / 46.30 | 5 | 139 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 29 | 14.89 | 427 | 184 | 0.18 / 37.59 | 5 | 6 |
2 | 7 | 2010.36 | 40 | 14.44 | 3030 | 1750 | 1.93 / 39.34 | 6 | 22 |
3 | 13 | 1290.60 | 20 | 14.57 | 2095 | 610 | 2.54 / 39.95 | 5 | 33 |
4 | 13 | 702.44 | 20 | 14.70 | 1336 | 393 | 2.94 / 40.34 | 5 | 36 |
5 | 13 | 113.56 | 20 | 14.90 | 484 | 144 | 3.08 / 40.49 | 5 | 36 |
6 | 13 | 30.72 | 20 | 14.93 | 357 | 107 | 3.19 / 40.59 | 5 | 35 |
7 | 8 | -0.12 | 267 | 14.89 | 304 | 1209 | 4.40 / 41.80 | 5 | 133 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 14.89 | 416 | 180 | 0.18 / 33.14 | 5 | 6 |
2 | 7 | 2006.44 | 41 | 14.45 | 2995 | 1774 | 1.95 / 34.92 | 7 | 24 |
3 | 13 | 1293.16 | 20 | 14.56 | 2110 | 614 | 2.57 / 35.53 | 5 | 32 |
4 | 13 | 710.32 | 20 | 14.70 | 1340 | 394 | 2.96 / 35.92 | 5 | 37 |
5 | 13 | 124.20 | 20 | 14.90 | 497 | 148 | 3.11 / 36.07 | 5 | 35 |
6 | 13 | 65.84 | 20 | 14.92 | 405 | 121 | 3.23 / 36.19 | 5 | 34 |
7 | 8 | 0.08 | 270 | 14.90 | 301 | 1211 | 4.44 / 37.40 | 5 | 138 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 29 | 14.90 | 416 | 180 | 0.18 / 28.77 | 5 | 6 |
2 | 7 | 2011.04 | 40 | 14.45 | 3017 | 1744 | 1.92 / 30.51 | 6 | 23 |
3 | 13 | 1285.56 | 20 | 14.57 | 2109 | 615 | 2.54 / 31.13 | 5 | 33 |
4 | 13 | 701.84 | 20 | 14.71 | 1323 | 389 | 2.93 / 31.52 | 5 | 37 |
5 | 13 | 133.04 | 20 | 14.90 | 507 | 151 | 3.08 / 31.67 | 5 | 34 |
6 | 13 | 70.28 | 20 | 14.93 | 409 | 122 | 3.20 / 31.79 | 5 | 33 |
7 | 8 | 0.08 | 270 | 14.91 | 291 | 1171 | 4.37 / 32.96 | 5 | 135 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 28 | 14.89 | 416 | 173 | 0.17 / 24.36 | 5 | 6 |
2 | 3 | 1027.20 | 1 | 14.85 | 1781 | 26 | 0.20 / 24.38 | 5 | 20 |
3 | 7 | 2009.36 | 40 | 14.44 | 3018 | 1743 | 1.94 / 26.13 | 20 | 22 |
4 | 13 | 1320.76 | 20 | 14.55 | 2172 | 632 | 2.58 / 26.76 | 5 | 32 |
5 | 13 | 642.08 | 20 | 14.73 | 1248 | 368 | 2.94 / 27.13 | 5 | 37 |
6 | 13 | 168.72 | 20 | 14.89 | 556 | 166 | 3.11 / 27.29 | 5 | 36 |
7 | 13 | 59.96 | 20 | 14.93 | 388 | 116 | 3.22 / 27.41 | 5 | 32 |
8 | 8 | 0.12 | 274 | 14.91 | 289 | 1181 | 4.40 / 28.59 | 5 | 169 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 27 | 14.91 | 405 | 163 | 0.16 / 19.84 | 5 | 6 |
2 | 10 | 1001.04 | 4 | 14.82 | 1707 | 101 | 0.26 / 19.94 | 5 | 16 |
3 | 3 | 923.36 | -1 | 15.31 | 2 | 0 | 0.10 / 19.94 | 5 | 16 |
4 | 7 | 2004.88 | 41 | 14.46 | 3012 | 1786 | 2.05 / 21.72 | 16 | 23 |
5 | 13 | 1290.04 | 20 | 14.57 | 2140 | 624 | 2.67 / 22.35 | 5 | 32 |
6 | 13 | 693.72 | 20 | 14.71 | 1327 | 390 | 3.06 / 22.74 | 5 | 37 |
7 | 13 | 185.80 | 20 | 14.88 | 588 | 175 | 3.24 / 22.91 | 5 | 37 |
8 | 13 | 53.32 | 20 | 14.94 | 374 | 112 | 3.35 / 23.03 | 5 | 34 |
9 | 8 | 0.04 | 270 | 14.91 | 288 | 1159 | 4.51 / 24.18 | 5 | 142 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 31 | 14.90 | 423 | 195 | 0.20 / 15.57 | 5 | 6 |
2 | 3 | 867.12 | -2 | 15.32 | 2 | 0 | 0.00 / 15.57 | 5 | 6 |
3 | 7 | 2005.96 | 40 | 14.47 | 3040 | 1760 | 1.95 / 17.33 | 6 | 22 |
4 | 13 | 1293.80 | 20 | 14.57 | 2137 | 623 | 2.58 / 17.95 | 5 | 32 |
5 | 13 | 617.80 | 20 | 14.74 | 1207 | 356 | 2.93 / 18.31 | 5 | 36 |
6 | 13 | 147.00 | 20 | 14.90 | 515 | 153 | 3.09 / 18.46 | 5 | 36 |
7 | 13 | 81.40 | 20 | 14.93 | 412 | 123 | 3.21 / 18.58 | 5 | 34 |
8 | 8 | 0.04 | 265 | 14.91 | 276 | 1091 | 4.30 / 19.67 | 5 | 135 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 28 | 14.90 | 421 | 176 | 0.18 / 11.78 | 5 | 6 |
2 | 7 | 1525.36 | 40 | 14.65 | 2412 | 1413 | 1.59 / 13.19 | 6 | 25 |
3 | 13 | 1111.80 | 20 | 14.68 | 1882 | 553 | 2.14 / 13.75 | 5 | 31 |
4 | 13 | 422.92 | 20 | 14.84 | 928 | 275 | 2.42 / 14.02 | 5 | 36 |
5 | 13 | 119.00 | 20 | 14.94 | 474 | 142 | 2.56 / 14.16 | 5 | 33 |
6 | 13 | 69.84 | 20 | 14.95 | 392 | 117 | 2.68 / 14.28 | 5 | 32 |
7 | 8 | 0.00 | 261 | 14.93 | 281 | 1095 | 3.77 / 15.37 | 5 | 135 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 27 | 14.90 | 408 | 164 | 0.16 / 7.90 | 5 | 6 |
2 | 3 | 1038.44 | 1 | 14.85 | 1790 | 27 | 0.19 / 7.92 | 5 | 23 |
3 | 7 | 1507.24 | 40 | 14.66 | 2385 | 1399 | 1.59 / 9.32 | 23 | 24 |
4 | 13 | 1182.20 | 20 | 14.67 | 1981 | 581 | 2.17 / 9.90 | 5 | 30 |
5 | 13 | 579.76 | 20 | 14.79 | 1145 | 339 | 2.51 / 10.24 | 5 | 35 |
6 | 13 | 122.04 | 20 | 14.93 | 474 | 142 | 2.65 / 10.38 | 5 | 33 |
7 | 13 | 70.28 | 20 | 14.95 | 391 | 117 | 2.77 / 10.50 | 5 | 32 |
8 | 8 | 0.04 | 267 | 14.93 | 277 | 1104 | 3.87 / 11.60 | 5 | 143 |
Average= | 2.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 14.95 | 403 | 187 | 0.19 / 4.13 | 5 | 6 |
2 | 3 | 866.16 | -2 | 15.33 | 2 | 0 | 0.00 / 4.13 | 5 | 6 |
3 | 7 | 1509.28 | 40 | 14.67 | 2356 | 1383 | 1.57 / 5.51 | 6 | 23 |
4 | 13 | 1196.40 | 20 | 14.66 | 1984 | 582 | 2.15 / 6.09 | 5 | 30 |
5 | 13 | 486.64 | 20 | 14.81 | 1015 | 301 | 2.45 / 6.39 | 5 | 35 |
6 | 13 | 133.20 | 20 | 14.92 | 495 | 148 | 2.60 / 6.54 | 5 | 34 |
7 | 13 | 49.72 | 20 | 14.96 | 354 | 106 | 2.71 / 6.65 | 5 | 32 |
8 | 8 | 0.08 | 265 | 14.92 | 274 | 1083 | 3.79 / 7.73 | 5 | 133 |
Average= | 2.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 31 | 15.12 | 376 | 176 | 0.18 / 1.69 | 6 | 6 |
2 | 3 | 841.96 | -2 | 15.35 | 2 | 0 | 0.00 / 1.69 | 6 | 6 |
3 | 7 | 886.20 | 40 | 14.85 | 1541 | 915 | 1.09 / 2.61 | 6 | 28 |
4 | 13 | 126.36 | 20 | 15.02 | 475 | 143 | 1.23 / 2.75 | 5 | 31 |
5 | 13 | 78.32 | 20 | 15.03 | 396 | 119 | 1.35 / 2.87 | 5 | 31 |
6 | 8 | 0.04 | 267 | 15.01 | 268 | 1074 | 2.43 / 3.94 | 5 | 139 |
Average= | 1.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 165.64 | 30 | 15.29 | 462 | 212 | 0.21 / 0.21 | 6 | 6 |
2 | 7 | 178.44 | 40 | 15.27 | 470 | 287 | 0.50 / 0.50 | 6 | 7 |
3 | 13 | 103.36 | 20 | 15.25 | 363 | 111 | 0.61 / 0.61 | 6 | 9 |
4 | 13 | 57.00 | 20 | 15.25 | 295 | 90 | 0.70 / 0.70 | 6 | 10 |
5 | 8 | -0.04 | 259 | 15.22 | 207 | 816 | 1.52 / 1.52 | 6 | 151 |
Average= | 1.52 (KJ/cycle) |