SIO Argo Site:
Pump Diagnostics Page   



Serial= 7822 WMO= 2903148

Return

←PreviousNext→

Cycle 37 GMT 22/11/2024 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 25 14.80 400 148 0.15 / 142.04 6 6
2 7 1731.84 40 14.44 2441 1410 1.56 / 143.44 6 14
3 13 1167.52 20 14.53 1760 511 2.07 / 143.96 6 19
4 13 605.04 20 14.66 1060 311 2.38 / 144.27 6 20
5 13 124.84 20 14.80 441 131 2.51 / 144.40 6 19
6 13 45.20 20 14.83 329 98 2.61 / 144.50 6 18
7 13 26.88 20 14.83 300 89 2.70 / 144.58 6 19
8 8 0.08 285 14.79 262 1104 3.80 / 145.69 6 135
Average= 3.83
(KJ/cycle)

Cycle 36 GMT 11/11/2024 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 25 14.78 383 142 0.14 / 138.55 6 6
2 7 1370.08 40 14.61 1999 1168 1.31 / 139.72 6 18
3 13 1175.76 20 14.62 1769 517 1.83 / 140.23 6 17
4 13 479.92 20 14.75 898 265 2.09 / 140.50 6 20
5 13 120.32 20 14.85 431 128 2.22 / 140.63 6 19
6 13 40.04 20 14.88 320 95 2.32 / 140.72 6 17
7 8 0.08 302 14.84 260 1165 3.48 / 141.89 6 132
Average= 3.83
(KJ/cycle)

Cycle 35 GMT 1/11/2024 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 25 14.78 395 146 0.15 / 134.59 6 6
2 7 1906.96 41 14.38 2641 1557 1.70 / 136.15 6 15
3 13 1224.04 20 14.50 1828 530 2.23 / 136.68 6 19
4 13 534.40 20 14.68 970 285 2.52 / 136.97 6 20
5 13 182.96 20 14.78 514 152 2.67 / 137.12 6 19
6 13 45.36 20 14.83 330 98 2.77 / 137.22 6 18
7 8 0.08 306 14.80 263 1191 3.96 / 138.41 6 144
Average= 3.84
(KJ/cycle)

Cycle 34 GMT 22/10/2024 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 26 14.79 395 152 0.15 / 130.54 6 6
2 7 2001.60 40 14.37 2757 1585 1.74 / 132.12 6 12
3 13 1279.28 20 14.49 1902 551 2.29 / 132.67 6 20
4 13 680.08 20 14.63 1162 340 2.63 / 133.01 6 21
5 13 110.32 20 14.82 414 123 2.75 / 133.14 6 19
6 13 63.24 20 14.83 358 106 2.86 / 133.24 6 18
7 13 15.24 20 14.84 287 85 2.94 / 133.33 6 19
8 8 0.04 287 14.80 264 1121 4.06 / 134.45 6 138
Average= 3.84
(KJ/cycle)

Cycle 33 GMT 11/10/2024 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 26 14.79 396 152 0.15 / 126.45 6 6
2 7 2001.80 40 14.37 2766 1590 1.74 / 128.04 6 12
3 13 1388.64 20 14.46 2045 591 2.33 / 128.63 6 19
4 13 675.60 20 14.64 1151 337 2.67 / 128.97 6 20
5 13 107.92 20 14.82 414 123 2.79 / 129.09 6 19
6 13 64.88 20 14.83 355 105 2.90 / 129.20 6 19
7 8 0.20 308 14.80 260 1185 4.08 / 130.38 6 139
Average= 3.83
(KJ/cycle)

Cycle 32 GMT 1/10/2024 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 25 14.81 385 143 0.14 / 122.41 6 6
2 3 1020.36 1 14.79 1587 23 0.17 / 122.44 6 10
3 7 2001.84 40 14.38 2748 1581 1.75 / 124.02 10 12
4 13 1288.92 20 14.50 1899 551 2.30 / 124.57 6 18
5 13 597.68 20 14.67 1050 308 2.61 / 124.88 6 19
6 13 128.68 20 14.81 441 131 2.74 / 125.01 6 19
7 13 68.80 20 14.83 360 107 2.84 / 125.11 6 18
8 8 0.00 308 14.81 260 1186 4.03 / 126.30 6 139
Average= 3.83
(KJ/cycle)

Cycle 31 GMT 21/ 9/2024 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 25 14.80 385 142 0.14 / 118.37 6 6
2 7 2005.12 40 14.37 2766 1590 1.73 / 119.96 9 12
3 13 1176.36 20 14.53 1763 512 2.24 / 120.47 6 17
4 13 870.20 20 14.59 1394 407 2.65 / 120.88 6 20
5 13 116.92 20 14.82 423 125 2.78 / 121.00 6 18
6 13 70.40 20 14.83 362 107 2.88 / 121.11 6 19
7 8 0.24 306 14.82 256 1161 4.05 / 122.27 6 135
Average= 3.82
(KJ/cycle)

Cycle 30 GMT 10/ 9/2024 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 25 14.81 384 142 0.14 / 114.36 6 6
2 7 2004.36 40 14.39 2764 1591 1.73 / 115.95 6 13
3 13 1290.84 20 14.51 1919 557 2.29 / 116.51 6 18
4 13 614.72 20 14.68 1065 313 2.60 / 116.82 6 19
5 13 130.76 20 14.83 442 131 2.73 / 116.95 6 18
6 13 57.08 20 14.85 342 102 2.84 / 117.05 6 18
7 8 0.12 308 14.82 257 1173 4.01 / 118.23 6 149
Average= 3.81
(KJ/cycle)

Cycle 29 GMT 31/ 8/2024 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 25 14.81 388 144 0.14 / 110.35 6 6
2 7 2005.16 40 14.38 2766 1591 1.73 / 111.95 6 14
3 13 1290.68 20 14.51 1906 553 2.29 / 112.50 6 20
4 13 605.72 20 14.68 1053 309 2.60 / 112.81 6 20
5 13 128.36 20 14.83 439 130 2.73 / 112.94 6 20
6 13 45.76 20 14.85 331 98 2.83 / 113.04 6 19
7 8 0.20 308 14.82 259 1182 4.01 / 114.22 6 148
Average= 3.81
(KJ/cycle)

Cycle 28 GMT 21/ 8/2024 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 25 14.81 395 146 0.15 / 106.33 6 6
2 7 2003.36 40 14.39 2755 1586 1.73 / 107.91 6 12
3 13 1274.48 20 14.52 1898 551 2.28 / 108.46 6 18
4 13 682.92 20 14.66 1158 340 2.62 / 108.80 6 20
5 13 98.76 20 14.84 404 120 2.74 / 108.92 6 19
6 13 46.36 20 14.86 332 99 2.84 / 109.02 6 18
7 8 0.16 308 14.83 260 1188 4.03 / 110.21 6 146
Average= 3.80
(KJ/cycle)

Cycle 27 GMT 11/ 8/2024 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 25 14.81 389 144 0.14 / 102.35 6 6
2 7 2004.16 40 14.39 2764 1591 1.73 / 103.94 6 12
3 13 1186.28 20 14.54 1786 519 2.25 / 104.46 6 19
4 13 617.56 20 14.69 1071 315 2.57 / 104.77 6 20
5 13 84.60 20 14.85 383 114 2.68 / 104.88 6 19
6 13 51.44 20 14.86 340 101 2.78 / 104.99 6 19
7 8 0.12 308 14.83 262 1197 3.98 / 106.18 6 150
Average= 3.79
(KJ/cycle)

Cycle 26 GMT 31/ 7/2024 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 25 14.82 392 145 0.15 / 98.36 6 6
2 7 2002.68 40 14.39 2757 1587 1.73 / 99.95 6 14
3 13 1251.88 20 14.53 1866 542 2.27 / 100.49 6 18
4 13 555.24 20 14.71 996 293 2.57 / 100.79 6 19
5 13 102.32 20 14.85 408 121 2.69 / 100.91 6 19
6 13 58.08 20 14.86 352 105 2.79 / 101.01 6 19
7 8 0.16 306 14.83 262 1189 3.98 / 102.20 6 136
Average= 3.79
(KJ/cycle)

Cycle 25 GMT 21/ 7/2024 10: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 25 14.83 393 146 0.15 / 94.32 6 6
2 7 2005.76 41 14.39 2763 1630 1.78 / 95.95 6 12
3 13 1267.12 20 14.53 1894 550 2.33 / 96.50 6 19
4 13 572.88 20 14.71 1017 299 2.63 / 96.80 6 20
5 13 106.84 20 14.85 414 123 2.75 / 96.93 6 19
6 13 50.60 20 14.87 337 100 2.85 / 97.03 6 18
7 8 0.16 308 14.84 261 1193 4.04 / 98.22 6 157
Average= 3.78
(KJ/cycle)

Cycle 24 GMT 11/ 7/2024 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 24 14.82 396 141 0.14 / 90.25 6 6
2 3 1049.32 1 14.78 1623 24 0.16 / 90.28 6 12
3 7 2003.12 40 14.39 2768 1593 1.76 / 91.87 12 12
4 13 1205.28 20 14.54 1809 526 2.28 / 92.40 6 19
5 13 734.56 20 14.65 1225 359 2.64 / 92.76 6 21
6 13 120.20 20 14.84 435 129 2.77 / 92.89 6 19
7 13 44.96 20 14.87 331 98 2.87 / 92.98 6 18
8 8 0.20 308 14.84 261 1193 4.06 / 94.18 6 146
Average= 3.77
(KJ/cycle)

Cycle 23 GMT 30/ 6/2024 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 26 14.84 369 142 0.14 / 86.16 6 6
2 3 925.64 -1 15.25 9 0 0.00 / 86.16 6 6
3 7 2003.04 40 14.39 2764 1591 1.73 / 87.75 6 12
4 13 1380.32 20 14.50 2032 589 2.32 / 88.34 6 18
5 13 643.24 20 14.69 1110 326 2.65 / 88.66 6 20
6 13 160.56 20 14.84 488 145 2.79 / 88.81 6 20
7 13 45.84 20 14.88 329 98 2.89 / 88.91 6 18
8 13 25.92 20 14.88 300 89 2.98 / 88.99 6 19
9 8 0.12 289 14.84 261 1119 4.10 / 90.11 6 149
Average= 3.75
(KJ/cycle)

Cycle 22 GMT 20/ 6/2024 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 25 14.85 383 142 0.14 / 82.19 6 6
2 7 2004.64 41 14.39 2758 1627 1.77 / 83.82 6 12
3 13 1182.12 20 14.56 1774 517 2.29 / 84.34 6 18
4 13 515.08 20 14.73 943 278 2.56 / 84.62 6 20
5 13 107.68 20 14.86 408 121 2.69 / 84.74 6 17
6 13 56.56 20 14.88 340 101 2.79 / 84.84 6 17
7 13 13.20 20 14.89 281 84 2.87 / 84.92 6 17
8 8 0.04 287 14.85 256 1091 3.96 / 86.01 6 144
Average= 3.74
(KJ/cycle)

Cycle 21 GMT 10/ 6/2024 5:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 24 14.84 388 138 0.14 / 78.17 6 6
2 3 1038.80 1 14.79 1614 24 0.16 / 78.19 6 11
3 7 2005.28 40 14.40 2762 1591 1.75 / 79.78 11 13
4 13 1268.24 20 14.55 1878 546 2.30 / 80.33 6 18
5 13 659.12 20 14.70 1121 330 2.63 / 80.66 6 20
6 13 105.20 20 14.87 404 120 2.75 / 80.78 6 18
7 13 58.16 20 14.88 340 101 2.85 / 80.88 6 17
8 13 20.64 20 14.90 287 86 2.94 / 80.97 6 17
9 8 0.20 287 14.86 255 1088 4.02 / 82.05 6 140
Average= 3.73
(KJ/cycle)

Cycle 20 GMT 30/ 5/2024 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 24 14.85 372 133 0.13 / 74.16 6 6
2 7 2002.64 41 14.41 2758 1629 1.76 / 75.79 6 12
3 13 1253.12 20 14.55 1874 545 2.31 / 76.34 6 19
4 13 564.72 20 14.73 1001 295 2.60 / 76.63 6 21
5 13 109.36 20 14.87 407 121 2.72 / 76.75 6 19
6 13 60.20 20 14.88 345 103 2.83 / 76.85 6 18
7 13 18.08 20 14.90 284 85 2.91 / 76.94 6 19
8 8 0.20 287 14.85 256 1091 4.00 / 78.03 6 143
Average= 3.72
(KJ/cycle)

Cycle 19 GMT 20/ 5/2024 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 25 14.85 381 141 0.14 / 70.19 6 6
2 3 960.00 -1 15.26 9 0 0.00 / 70.19 6 6
3 7 2001.72 40 14.41 2758 1590 1.73 / 71.78 6 13
4 13 1196.68 20 14.57 1801 525 2.26 / 72.30 6 18
5 13 619.68 20 14.71 1076 317 2.57 / 72.62 6 20
6 13 133.56 20 14.86 448 133 2.71 / 72.75 6 19
7 13 54.40 20 14.89 339 101 2.81 / 72.85 6 18
8 13 17.04 20 14.90 286 85 2.89 / 72.94 6 18
9 8 0.12 287 14.86 255 1088 3.98 / 74.03 6 133
Average= 3.70
(KJ/cycle)

Cycle 18 GMT 10/ 5/2024 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 25 14.85 396 147 0.15 / 66.13 6 6
2 3 1022.92 1 14.83 1558 23 0.17 / 66.15 6 10
3 7 2003.36 40 14.41 2770 1597 1.77 / 67.75 10 13
4 13 1279.80 20 14.55 1907 555 2.32 / 68.30 6 18
5 13 599.52 20 14.72 1052 310 2.63 / 68.61 6 20
6 13 134.04 20 14.87 450 134 2.77 / 68.75 6 19
7 13 64.48 20 14.89 351 105 2.87 / 68.85 6 17
8 13 41.24 20 14.89 319 95 2.96 / 68.95 6 18
9 8 0.16 287 14.86 258 1100 4.07 / 70.05 6 134
Average= 3.69
(KJ/cycle)

Cycle 17 GMT 30/ 4/2024 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 24 14.85 386 138 0.14 / 62.17 6 6
2 7 2001.40 40 14.42 2756 1590 1.73 / 63.76 7 12
3 13 1167.32 20 14.58 1766 515 2.24 / 64.27 6 19
4 13 591.32 20 14.73 1034 305 2.55 / 64.58 6 20
5 13 103.60 20 14.88 404 120 2.67 / 64.70 6 20
6 13 64.00 20 14.89 353 105 2.77 / 64.80 6 20
7 13 41.04 20 14.89 318 95 2.87 / 64.90 6 20
8 8 0.04 285 14.86 256 1084 3.95 / 65.98 6 133
Average= 3.67
(KJ/cycle)

Cycle 16 GMT 19/ 4/2024 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 25 14.86 385 143 0.14 / 58.26 6 6
2 7 2005.68 40 14.42 2765 1595 1.74 / 59.86 6 12
3 13 1158.68 20 14.59 1751 511 2.25 / 60.37 6 19
4 13 498.08 20 14.76 919 271 2.52 / 60.64 6 19
5 13 78.92 20 14.89 374 111 2.63 / 60.75 6 19
6 13 42.88 20 14.90 325 97 2.73 / 60.85 6 20
7 13 17.48 20 14.91 286 85 2.81 / 60.93 6 19
8 8 0.12 285 14.86 260 1101 3.91 / 62.03 6 145
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 9/ 4/2024 10:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 25 14.86 384 143 0.14 / 54.25 6 6
2 7 2004.24 40 14.44 2756 1592 1.73 / 55.84 6 12
3 13 1281.92 20 14.56 1906 555 2.29 / 56.39 6 18
4 13 656.68 20 14.72 1119 329 2.62 / 56.72 6 21
5 13 89.32 20 14.89 392 117 2.74 / 56.84 6 19
6 13 31.80 20 14.91 314 94 2.83 / 56.93 6 19
7 8 0.12 306 14.87 260 1183 4.01 / 58.12 6 131
Average= 3.63
(KJ/cycle)

Cycle 14 GMT 30/ 3/2024 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 25 14.87 385 143 0.14 / 50.32 6 6
2 7 2002.88 40 14.43 2754 1590 1.73 / 51.91 6 13
3 13 1160.04 20 14.60 1762 515 2.25 / 52.43 6 19
4 13 594.24 20 14.74 1044 308 2.56 / 52.73 6 20
5 13 65.00 20 14.90 358 107 2.66 / 52.84 6 20
6 13 34.12 20 14.91 313 93 2.76 / 52.93 6 19
7 8 0.20 304 14.88 259 1172 3.93 / 54.11 6 132
Average= 3.61
(KJ/cycle)

Cycle 13 GMT 19/ 3/2024 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 25 14.86 385 143 0.14 / 46.32 6 6
2 7 2003.36 41 14.44 2766 1638 1.78 / 47.96 6 13
3 13 1254.48 20 14.58 1874 546 2.33 / 48.50 6 21
4 13 555.08 20 14.76 992 293 2.62 / 48.80 6 21
5 13 93.92 20 14.90 396 118 2.74 / 48.92 6 19
6 13 28.60 20 14.92 307 92 2.83 / 49.01 6 20
7 8 0.20 304 14.88 259 1172 4.00 / 50.18 6 132
Average= 3.58
(KJ/cycle)

Cycle 12 GMT 9/ 3/2024 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 25 14.87 384 143 0.14 / 42.35 6 6
2 7 2002.44 40 14.45 2761 1596 1.74 / 43.94 6 11
3 13 1175.88 20 14.60 1785 521 2.26 / 44.47 6 18
4 13 600.28 20 14.75 1051 310 2.57 / 44.78 6 19
5 13 109.96 20 14.89 418 124 2.69 / 44.90 6 19
6 13 30.60 20 14.92 312 93 2.79 / 44.99 6 20
7 8 0.20 306 14.88 260 1184 3.97 / 46.18 6 139
Average= 3.55
(KJ/cycle)

Cycle 11 GMT 28/ 2/2024 6:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 25 14.88 385 143 0.14 / 38.36 6 6
2 7 2004.20 41 14.45 2758 1634 1.78 / 40.00 6 12
3 13 1163.52 20 14.62 1747 511 2.29 / 40.51 6 20
4 13 590.88 20 14.75 1038 306 2.59 / 40.82 6 20
5 13 100.76 20 14.90 408 122 2.72 / 40.94 6 20
6 13 29.44 20 14.92 308 92 2.81 / 41.03 6 20
7 8 0.12 304 14.89 260 1177 3.98 / 42.21 6 131
Average= 3.52
(KJ/cycle)

Cycle 10 GMT 17/ 2/2024 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 25 14.87 391 145 0.15 / 34.39 6 6
2 7 2002.00 40 14.45 2759 1595 1.74 / 35.99 6 13
3 13 1248.92 20 14.59 1862 543 2.28 / 36.53 6 18
4 13 559.36 20 14.77 1001 296 2.58 / 36.83 6 20
5 13 99.64 20 14.91 404 120 2.70 / 36.95 6 19
6 13 33.60 20 14.93 311 93 2.79 / 37.04 6 19
7 8 0.20 306 14.89 259 1180 3.97 / 38.22 6 138
Average= 3.47
(KJ/cycle)

Cycle 9 GMT 7/ 2/2024 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 25 14.88 390 145 0.15 / 30.44 6 6
2 7 2003.68 41 14.45 2756 1633 1.78 / 32.08 6 12
3 13 1167.64 20 14.61 1763 515 2.29 / 32.59 6 17
4 13 504.72 20 14.78 934 276 2.57 / 32.87 6 20
5 13 90.56 20 14.91 386 115 2.68 / 32.98 6 19
6 13 28.80 20 14.93 304 91 2.77 / 33.07 6 19
7 8 0.16 306 14.90 258 1176 3.95 / 34.25 6 142
Average= 3.42
(KJ/cycle)

Cycle 8 GMT 28/ 1/2024 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 25 14.88 387 144 0.14 / 26.48 6 6
2 7 2001.60 40 14.46 2749 1590 1.73 / 28.07 6 13
3 13 1255.56 20 14.60 1873 547 2.28 / 28.62 6 17
4 13 557.96 20 14.78 992 293 2.57 / 28.91 6 21
5 13 107.08 20 14.91 405 121 2.69 / 29.03 6 20
6 13 60.72 20 14.92 344 103 2.80 / 29.13 6 20
7 8 0.12 306 14.90 255 1163 3.96 / 30.30 6 141
Average= 3.37
(KJ/cycle)

Cycle 7 GMT 18/ 1/2024 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 25 14.88 393 146 0.15 / 22.55 6 6
2 7 2003.36 40 14.46 2754 1593 1.74 / 24.14 6 12
3 13 1266.12 20 14.60 1875 547 2.29 / 24.69 6 17
4 13 488.36 20 14.80 908 269 2.56 / 24.96 6 20
5 13 131.52 20 14.90 445 133 2.69 / 25.09 6 20
6 13 49.08 20 14.94 325 97 2.79 / 25.19 6 18
7 8 0.04 306 14.91 252 1150 3.93 / 26.34 6 129
Average= 3.29
(KJ/cycle)

Cycle 6 GMT 7/ 1/2024 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 23 14.90 385 132 0.13 / 18.49 6 6
2 10 1042.04 3 14.80 1595 71 0.20 / 18.56 6 9
3 7 2004.36 40 14.47 2743 1588 1.79 / 20.15 9 14
4 13 1179.20 20 14.63 1780 521 2.31 / 20.67 6 18
5 13 695.52 20 14.74 1169 345 2.66 / 21.01 6 21
6 13 99.20 20 14.92 397 118 2.77 / 21.13 6 19
7 13 59.52 20 14.93 344 103 2.88 / 21.23 6 19
8 13 15.84 20 14.94 280 84 2.96 / 21.32 6 20
9 8 0.12 287 14.90 254 1086 4.05 / 22.40 6 133
Average= 3.20
(KJ/cycle)

Cycle 5 GMT 28/12/2023 12: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 31 14.90 390 180 0.18 / 14.61 6 6
2 3 746.52 -4 15.29 9 0 0.00 / 14.61 6 6
3 7 2006.36 40 14.47 2748 1591 1.77 / 16.20 6 12
4 13 1109.08 20 14.64 1692 495 2.27 / 16.70 6 18
5 13 547.72 20 14.78 982 290 2.56 / 16.99 6 20
6 13 98.80 20 14.92 395 118 2.67 / 17.10 6 19
7 13 62.12 20 14.93 343 102 2.78 / 17.21 6 19
8 8 0.04 306 14.91 252 1150 3.93 / 18.36 6 153
Average= 3.06
(KJ/cycle)

Cycle 4 GMT 18/12/2023 4: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 23 14.90 384 132 0.13 / 10.99 6 6
2 3 1058.24 1 14.86 1601 24 0.16 / 11.02 6 14
3 7 1507.20 40 14.66 2151 1261 1.42 / 12.28 14 13
4 13 1172.68 20 14.69 1758 517 1.93 / 12.80 6 16
5 13 468.44 20 14.85 877 260 2.19 / 13.06 6 18
6 13 98.92 20 14.95 394 118 2.31 / 13.17 6 18
7 13 57.08 20 14.96 341 102 2.41 / 13.28 6 19
8 8 0.16 304 14.93 254 1153 3.57 / 14.43 6 152
Average= 2.89
(KJ/cycle)

Cycle 3 GMT 16/12/2023 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 22 14.90 367 120 0.12 / 7.48 6 6
2 3 1031.40 1 14.86 1584 24 0.14 / 7.50 6 10
3 7 1513.72 40 14.66 2160 1267 1.41 / 8.77 10 14
4 13 1102.56 20 14.70 1673 492 1.90 / 9.26 6 17
5 13 418.80 20 14.85 813 241 2.14 / 9.50 6 19
6 13 98.12 20 14.95 396 118 2.26 / 9.62 6 18
7 13 64.40 20 14.95 347 104 2.37 / 9.73 6 18
8 8 0.12 302 14.93 252 1136 3.50 / 10.86 6 132
Average= 2.72
(KJ/cycle)

Cycle 2 GMT 15/12/2023 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 14.96 384 178 0.18 / 4.03 6 6
2 3 738.76 -4 15.31 9 0 0.00 / 4.03 6 6
3 7 1519.28 40 14.67 2168 1272 1.45 / 5.30 6 14
4 13 1085.44 20 14.71 1641 483 1.93 / 5.78 6 17
5 13 406.12 20 14.86 794 236 2.17 / 6.02 6 18
6 13 103.32 20 14.94 397 119 2.29 / 6.14 6 17
7 13 66.52 20 14.95 346 103 2.39 / 6.24 6 17
8 8 0.08 302 14.93 248 1118 3.51 / 7.36 6 131
Average= 2.45
(KJ/cycle)

Cycle 1 GMT 13/12/2023 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 15.14 364 171 0.17 / 1.70 6 6
2 3 762.64 -4 15.34 9 0 0.00 / 1.70 6 6
3 7 856.40 40 14.87 1351 804 0.97 / 2.51 6 18
4 13 115.96 20 15.03 410 123 1.10 / 2.63 6 15
5 13 79.52 20 15.04 360 108 1.21 / 2.74 6 16
6 8 0.20 304 15.01 244 1113 2.32 / 3.85 6 133
Average= 1.93
(KJ/cycle)

Cycle 0 GMT 13/12/2023 11:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.44 30 15.29 384 176 0.18 / 0.18 6 7
2 7 148.20 41 15.27 396 248 0.42 / 0.42 7 7
3 13 95.64 20 15.26 329 100 0.52 / 0.52 6 8
4 13 57.12 20 15.25 280 85 0.61 / 0.61 6 8
5 8 0.08 297 15.22 204 922 1.53 / 1.53 6 130
Average= 1.53
(KJ/cycle)