SIO Argo Site:
Pump Diagnostics Page   



Serial= 6121 WMO= 7901073

Return

←PreviousNext→

Cycle 41 GMT 5/ 3/2025 22:22: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.8 10 10 15.12 423 64 0.06 / 283.10 3 12
2 6 3003.5 275 97 14.82 2227 3201 3.27 / 286.30 3 30
3 3 2405.7 396 21 14.94 1866 585 3.85 / 286.88 3 31
4 7 1525.5 12639 80 15.25 1326 1618 5.47 / 288.50 3 33
5 13 1293.9 12681 80 15.18 1180 1433 6.90 / 289.93 3 35
6 13 979.7 12723 80 15.16 982 1191 8.09 / 291.13 3 35
7 13 727.2 12752 80 15.14 835 1011 9.10 / 292.14 3 31
8 14 -0.2 12832 365 15.14 356 1967 11.07 / 294.10 3 112
Average= 7.00
(KJ/cycle)

Cycle 40 GMT 24/ 2/2025 20:27: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.5 10 10 15.13 396 60 0.06 / 272.20 3 11
2 6 3003.7 280 96 14.83 2234 3181 3.24 / 275.38 3 30
3 3 2415.6 401 22 14.95 1883 619 3.86 / 276.00 3 31
4 7 1503.4 12644 80 15.26 1327 1620 5.48 / 277.62 3 33
5 13 1090.5 12723 80 15.21 1063 1293 6.77 / 278.92 3 35
6 13 870.8 12753 80 15.18 925 1123 7.90 / 280.04 3 34
7 13 736.1 12767 80 15.14 847 1026 8.92 / 281.07 3 32
8 14 -0.6 12847 360 15.14 361 1968 10.89 / 283.03 3 107
Average= 6.90
(KJ/cycle)

Cycle 39 GMT 15/ 2/2025 18:12: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.6 10 10 15.13 418 63 0.06 / 261.33 3 13
2 6 3005.6 271 96 14.82 2216 3153 3.22 / 264.49 3 30
3 3 2396.0 392 20 14.96 1845 552 3.77 / 265.04 3 31
4 7 1535.8 12635 80 15.26 1332 1626 5.39 / 266.66 3 33
5 13 1089.6 12720 80 15.22 1057 1287 6.68 / 267.95 3 34
6 13 962.6 12738 80 15.17 987 1198 7.88 / 269.15 3 35
7 13 722.2 12764 80 15.15 841 1019 8.90 / 270.17 3 32
8 14 -0.1 12845 362 15.15 360 1974 10.87 / 272.14 3 108
Average= 6.80
(KJ/cycle)

Cycle 38 GMT 6/ 2/2025 16: 1: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.9 10 10 15.13 419 63 0.06 / 250.48 3 14
2 6 3006.6 267 96 14.83 2229 3173 3.24 / 253.65 3 29
3 3 2404.7 388 21 14.96 1875 589 3.83 / 254.24 3 31
4 7 1531.5 6391 80 15.25 1328 1620 5.45 / 255.86 3 33
5 13 1156.3 6463 80 15.21 1097 1335 6.78 / 257.20 3 34
6 13 892.6 6500 80 15.18 941 1143 7.92 / 258.34 3 35
7 13 732.2 6517 80 15.14 845 1023 8.95 / 259.36 3 31
8 14 -0.3 6598 362 15.15 348 1909 10.86 / 261.27 3 115
Average= 6.70
(KJ/cycle)

Cycle 37 GMT 1/ 2/2025 22: 0: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.3 10 10 15.14 423 64 0.06 / 239.65 3 13
2 6 3006.5 275 96 14.83 2233 3179 3.24 / 242.83 3 30
3 3 2402.5 396 21 14.96 1870 587 3.83 / 243.42 3 30
4 7 1544.8 6399 80 15.25 1330 1623 5.45 / 245.04 3 33
5 13 1133.6 6478 80 15.22 1087 1324 6.78 / 246.36 3 35
6 13 825.9 6520 80 15.20 894 1087 7.86 / 247.45 3 33
7 13 730.4 6530 80 15.15 838 1016 8.88 / 248.47 3 32
8 14 -0.1 6613 365 15.16 352 1948 10.83 / 250.42 3 104
Average= 6.59
(KJ/cycle)

Cycle 36 GMT 28/ 1/2025 3:44: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.0 10 10 15.14 408 62 0.06 / 228.80 3 14
2 6 3005.4 280 95 14.84 2225 3137 3.20 / 231.94 3 29
3 3 2418.1 401 22 14.96 1857 611 3.81 / 232.55 3 31
4 7 1524.9 6404 80 15.26 1323 1615 5.42 / 234.17 3 33
5 13 1144.1 6477 80 15.22 1083 1319 6.74 / 235.48 3 33
6 13 874.8 6513 80 15.19 927 1126 7.87 / 236.61 3 34
7 13 747.7 6527 80 15.15 849 1029 8.90 / 237.64 3 32
8 14 -0.3 6610 362 15.16 355 1948 10.85 / 239.59 3 115
Average= 6.48
(KJ/cycle)

Cycle 35 GMT 23/ 1/2025 9:32: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.0 10 10 15.15 383 58 0.06 / 217.82 3 12
2 6 3005.2 282 95 14.84 2232 3147 3.20 / 220.97 3 31
3 3 2409.8 403 21 14.97 1871 588 3.79 / 221.56 3 31
4 7 1529.3 6407 80 15.26 1325 1618 5.41 / 223.17 3 33
5 13 1243.4 6461 80 15.21 1158 1409 6.82 / 224.58 3 35
6 13 925.1 6503 80 15.19 963 1170 7.99 / 225.75 3 34
7 13 733.8 6523 80 15.16 843 1022 9.01 / 226.78 3 32
8 14 -0.4 6604 360 15.16 360 1965 10.98 / 228.74 3 101
Average= 6.35
(KJ/cycle)

Cycle 34 GMT 18/ 1/2025 15:22: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 10 10 15.15 404 61 0.06 / 206.96 3 13
2 6 3006.1 269 95 14.85 2226 3140 3.20 / 210.10 3 30
3 3 2408.2 390 21 14.98 1864 586 3.79 / 210.69 3 30
4 7 1526.4 6393 80 15.27 1325 1619 5.41 / 212.31 3 33
5 13 1055.2 6483 80 15.24 1041 1269 6.68 / 213.58 3 35
6 13 928.1 6501 80 15.19 970 1179 7.85 / 214.76 3 34
7 13 737.8 6522 80 15.16 850 1031 8.89 / 215.79 3 31
8 14 -0.1 6605 362 15.16 360 1976 10.86 / 217.76 3 123
Average= 6.22
(KJ/cycle)

Cycle 33 GMT 13/ 1/2025 21: 1: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.9 10 10 15.14 401 61 0.06 / 195.99 3 14
2 6 3003.3 257 96 14.85 2227 3175 3.24 / 199.16 3 30
3 3 2384.2 378 20 14.98 1857 556 3.79 / 199.72 3 31
4 7 1537.6 6381 80 15.27 1339 1636 5.43 / 201.35 3 34
5 13 1150.5 6453 80 15.23 1102 1343 6.77 / 202.70 3 35
6 13 971.8 6477 80 15.19 992 1205 7.98 / 203.90 3 34
7 13 733.1 6504 80 15.16 849 1030 9.01 / 204.93 3 32
8 14 -0.4 6585 362 15.16 359 1970 10.98 / 206.90 3 129
Average= 6.09
(KJ/cycle)

Cycle 32 GMT 9/ 1/2025 3: 2: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 10 10 15.16 401 61 0.06 / 185.01 3 13
2 6 3003.3 243 97 14.85 2231 3214 3.27 / 188.22 3 29
3 3 2394.2 365 20 14.99 1866 559 3.83 / 188.78 3 31
4 7 1519.4 6368 80 15.27 1330 1625 5.46 / 190.41 3 32
5 13 1139.4 6440 80 15.24 1099 1340 6.80 / 191.75 3 34
6 13 966.0 6464 80 15.20 988 1201 8.00 / 192.95 3 34
7 13 724.5 6490 80 15.17 836 1015 9.01 / 193.96 3 30
8 14 -0.2 6571 362 15.17 358 1966 10.98 / 195.93 3 116
Average= 5.94
(KJ/cycle)

Cycle 31 GMT 4/ 1/2025 9: 4: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.1 10 10 15.16 420 64 0.06 / 174.18 3 13
2 6 3005.3 274 98 14.85 2234 3251 3.31 / 177.43 3 29
3 3 2398.5 395 21 14.98 1862 586 3.90 / 178.02 3 31
4 7 1490.1 6398 80 15.29 1305 1596 5.50 / 179.61 3 32
5 13 1075.9 6476 80 15.25 1048 1279 6.78 / 180.89 3 34
6 13 817.2 6512 80 15.23 891 1086 7.86 / 181.98 3 34
7 13 738.0 6521 80 15.18 847 1029 8.89 / 183.01 3 30
8 14 -0.5 6602 358 15.18 357 1940 10.83 / 184.95 3 119
Average= 5.78
(KJ/cycle)

Cycle 30 GMT 30/12/2024 14:55: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.7 10 10 15.17 405 61 0.06 / 163.29 3 13
2 6 3003.3 280 101 14.85 2229 3343 3.40 / 166.63 3 28
3 3 2386.5 401 20 14.99 1873 562 3.97 / 167.20 3 30
4 7 1471.5 6404 80 15.29 1302 1593 5.56 / 168.79 3 33
5 13 1088.9 6477 80 15.26 1064 1299 6.86 / 170.09 3 35
6 13 783.9 6519 80 15.24 877 1069 7.93 / 171.16 3 33
7 13 734.1 6524 80 15.18 840 1020 8.95 / 172.18 3 30
8 14 -0.1 6605 354 15.18 361 1940 10.89 / 174.12 3 122
Average= 5.62
(KJ/cycle)

Cycle 29 GMT 25/12/2024 20:47: 3

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 10 10 15.19 399 61 0.06 / 152.25 3 13
2 6 3003.7 269 106 14.85 2242 3529 3.59 / 155.78 3 29
3 3 2376.3 391 19 15.00 1841 525 4.11 / 156.31 3 32
4 7 1421.8 6394 80 15.31 1275 1562 5.68 / 157.87 3 32
5 13 1000.1 6472 80 15.27 1006 1229 6.90 / 159.10 3 34
6 13 958.3 6478 80 15.21 975 1186 8.09 / 160.28 3 34
7 13 713.7 6505 80 15.19 836 1016 9.11 / 161.30 3 32
8 14 -0.3 6582 347 15.19 366 1929 11.04 / 163.23 3 126
Average= 5.44
(KJ/cycle)

Cycle 28 GMT 21/12/2024 3: 3: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.9 11 30 15.16 414 188 0.19 / 142.69 3 17
2 6 2840.2 414 106 14.90 2148 3393 3.58 / 146.08 3 31
3 3 2145.3 535 7 15.07 1736 183 3.76 / 146.26 3 31
4 7 1245.6 6538 80 15.34 1161 1425 5.19 / 147.69 3 33
5 13 987.1 6586 80 15.29 1009 1234 6.42 / 148.92 3 34
6 13 731.2 6619 80 15.26 846 1033 7.46 / 149.96 3 32
7 14 -0.3 6711 412 15.22 357 2239 9.69 / 152.19 3 116
Average= 5.25
(KJ/cycle)

Cycle 27 GMT 16/12/2024 7: 7:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.1 11 30 15.19 398 181 0.18 / 132.38 3 16
2 6 -99.0 492 96 14.90 2164 3095 3.28 / 135.47 3 29
3 7 1486.2 6466 80 15.30 1313 1607 4.88 / 137.08 3 31
4 13 1103.1 6538 80 15.27 1078 1317 6.20 / 138.40 3 33
5 13 881.5 6568 80 15.24 934 1139 7.34 / 139.54 3 32
6 13 730.3 6585 80 15.20 840 1021 8.36 / 140.56 3 29
7 14 -0.2 6665 354 15.19 361 1941 10.30 / 142.50 3 107
Average= 5.09
(KJ/cycle)

Cycle 26 GMT 11/12/2024 12: 0: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.6 10 10 15.08 389 59 0.06 / 122.12 3 12
2 6 3024.7 302 79 14.83 2259 2647 2.71 / 124.76 3 26
3 3 2729.4 363 39 14.85 2076 1202 3.91 / 125.96 3 27
4 3 2376.8 424 19 14.93 1871 531 4.44 / 126.49 3 28
5 7 1227.5 6247 80 15.35 1151 1413 5.85 / 127.91 3 29
6 13 993.1 6289 80 15.30 999 1223 7.07 / 129.13 3 31
7 13 735.0 6322 80 15.27 838 1024 8.10 / 130.15 3 30
8 14 -0.7 6415 384 15.24 349 2042 10.14 / 132.20 3 113
Average= 4.90
(KJ/cycle)

Cycle 25 GMT 6/12/2024 21: 1: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.0 10 10 15.08 398 60 0.06 / 111.02 3 14
2 6 2837.7 216 22 14.94 2141 704 0.76 / 111.73 3 25
3 3 2863.6 282 12 14.97 2187 393 1.16 / 112.12 3 27
4 7 2699.5 902 80 15.02 2071 2489 3.65 / 114.61 3 32
5 13 1982.4 1052 80 15.03 1616 1943 5.59 / 116.55 3 34
6 13 1299.0 1166 80 15.08 1189 1434 7.02 / 117.98 3 34
7 13 983.7 1208 80 15.08 987 1191 8.21 / 119.18 3 34
8 13 742.8 1235 80 15.07 835 1007 9.22 / 120.18 3 32
9 14 0.2 1318 360 15.09 345 1874 11.09 / 122.06 3 108
Average= 4.69
(KJ/cycle)

Cycle 24 GMT 5/12/2024 19: 2:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.8 10 10 15.19 391 59 0.06 / 100.03 3 11
2 6 3173.9 450 4 15.05 2395 144 0.20 / 100.17 3 23
3 3 3126.0 511 8 15.05 2355 284 0.49 / 100.45 3 25
4 3 3038.4 572 3 15.09 2413 109 0.60 / 100.56 3 23
5 7 2978.6 1115 80 15.00 2246 2695 3.29 / 103.26 3 30
6 13 2101.5 1313 80 15.04 1705 2051 5.34 / 105.31 3 32
7 13 1362.0 1445 80 15.10 1229 1485 6.83 / 106.79 3 31
8 13 988.2 1499 80 15.10 993 1200 8.03 / 107.99 3 33
9 13 732.7 1528 80 15.09 828 1000 9.03 / 108.99 3 30
10 14 0.0 1613 380 15.11 343 1969 11.00 / 110.96 3 112
Average= 4.44
(KJ/cycle)

Cycle 23 GMT 4/12/2024 12: 4: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.1 12 113 15.17 371 636 0.64 / 95.31 3 18
2 6 1010.4 198 59 15.07 989 879 1.52 / 96.19 3 25
3 3 826.9 259 11 15.16 917 153 1.67 / 96.34 3 24
4 3 648.9 320 2 15.23 807 25 1.69 / 96.36 3 24
5 7 380.6 623 80 15.34 601 738 2.43 / 97.10 3 27
6 13 348.0 629 80 15.29 565 691 3.12 / 97.79 3 26
7 14 -0.1 682 435 15.23 328 2173 5.29 / 99.97 3 116
Average= 4.17
(KJ/cycle)

Cycle 22 GMT 4/12/2024 0:32: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.7 12 110 15.17 370 617 0.62 / 90.02 3 18
2 6 1008.2 195 59 15.09 986 878 1.50 / 90.89 3 24
3 3 834.5 256 11 15.17 899 150 1.65 / 91.04 3 24
4 3 661.8 317 3 15.24 817 37 1.68 / 91.08 3 24
5 7 406.3 620 80 15.34 606 744 2.43 / 91.82 3 25
6 13 374.3 626 80 15.29 578 707 3.13 / 92.53 3 24
7 14 -0.1 684 435 15.23 323 2140 5.27 / 94.67 3 105
Average= 4.12
(KJ/cycle)

Cycle 21 GMT 3/12/2024 12:57: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.3 11 79 15.28 375 453 0.45 / 84.10 3 17
2 6 1010.7 158 59 15.14 993 887 1.34 / 84.99 3 23
3 3 1068.0 219 23 15.18 1041 363 1.70 / 85.35 3 24
4 3 915.4 280 15 15.24 954 218 1.92 / 85.57 3 24
5 3 740.2 340 7 15.29 855 92 2.01 / 85.66 3 24
6 7 431.6 583 80 15.35 643 790 2.80 / 86.45 3 25
7 13 398.3 589 80 15.30 606 742 3.54 / 87.19 3 27
8 14 -0.5 649 437 15.24 331 2204 5.75 / 89.40 3 128
Average= 4.06
(KJ/cycle)

Cycle 20 GMT 3/12/2024 1:58: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.9 13 155 15.34 359 854 0.85 / 80.05 3 19
2 6 785.6 72 59 15.16 859 768 1.62 / 80.81 3 25
3 7 0.6 497 80 15.46 343 424 2.05 / 81.24 3 17
4 14 0.0 509 489 15.36 321 2411 4.46 / 83.65 3 118
Average= 3.98
(KJ/cycle)

Cycle 19 GMT 2/12/2024 13:28: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.2 13 178 15.31 356 970 0.97 / 75.98 3 17
2 6 409.1 111 59 15.20 612 549 1.52 / 76.53 3 24
3 7 0.1 955 80 15.54 341 424 1.94 / 76.96 3 16
4 14 0.1 967 463 15.43 313 2236 4.18 / 79.19 3 121
Average= 3.96
(KJ/cycle)

Cycle 18 GMT 1/12/2024 17:57: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.5 13 202 14.77 349 1041 1.04 / 72.09 3 18
2 6 126.9 123 58 15.07 436 381 1.42 / 72.47 3 22
3 7 0.2 967 80 15.51 335 416 1.84 / 72.88 3 17
4 14 0.2 979 446 15.41 310 2131 3.97 / 75.01 3 120
Average= 3.95
(KJ/cycle)

Cycle 17 GMT 30/11/2024 22:26:58

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.4 14 257 14.76 341 1294 1.29 / 68.68 3 15
2 7 -0.2 35 80 14.81 308 365 1.66 / 69.04 3 22
3 14 0.0 47 472 14.77 287 2001 3.66 / 71.05 3 109
Average= 3.95
(KJ/cycle)

Cycle 16 GMT 30/11/2024 21:33: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.6 14 257 14.77 331 1256 1.26 / 65.00 3 17
2 7 -0.2 35 80 14.82 306 363 1.62 / 65.36 3 19
3 14 0.1 47 472 14.77 290 2022 3.64 / 67.39 3 110
Average= 3.96
(KJ/cycle)

Cycle 15 GMT 30/11/2024 20:40: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.0 14 257 14.76 334 1267 1.27 / 61.41 3 18
2 7 -0.3 40 80 14.82 308 365 1.63 / 61.78 3 16
3 14 0.0 51 472 14.78 282 1967 3.60 / 63.74 3 117
Average= 3.98
(KJ/cycle)

Cycle 14 GMT 30/11/2024 19:41: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.1 15 286 14.76 342 1444 1.44 / 57.90 3 16
2 7 -0.3 31 80 14.80 306 362 1.81 / 58.26 3 16
3 14 0.0 43 444 14.76 288 1887 3.69 / 60.15 3 121
Average= 4.01
(KJ/cycle)

Cycle 13 GMT 30/11/2024 18:52: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.8 15 286 14.77 345 1457 1.46 / 54.16 3 18
2 7 -0.1 36 80 14.81 314 372 1.83 / 54.53 3 20
3 14 0.0 47 446 14.77 292 1924 3.75 / 56.45 3 111
Average= 4.03
(KJ/cycle)

Cycle 12 GMT 30/11/2024 17:57: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.7 15 286 14.77 347 1466 1.47 / 50.39 3 17
2 7 -0.3 36 80 14.81 317 376 1.84 / 50.76 3 20
3 14 0.1 47 444 14.77 295 1935 3.78 / 52.70 3 117
Average= 4.05
(KJ/cycle)

Cycle 11 GMT 30/11/2024 17: 3: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.2 15 285 14.78 346 1457 1.46 / 46.60 3 18
2 7 -0.1 36 80 14.82 312 370 1.83 / 46.97 3 13
3 14 0.0 47 446 14.78 297 1958 3.79 / 48.92 3 118
Average= 4.08
(KJ/cycle)

Cycle 10 GMT 30/11/2024 16: 9: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.5 15 285 14.79 347 1463 1.46 / 42.81 3 16
2 7 -0.1 36 80 14.83 313 371 1.83 / 43.18 3 16
3 14 -0.1 47 446 14.79 297 1959 3.79 / 45.14 3 120
Average= 4.10
(KJ/cycle)

Cycle 9 GMT 30/11/2024 15:15: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.4 15 285 14.80 355 1497 1.50 / 39.02 3 17
2 7 -0.2 36 80 14.84 318 378 1.87 / 39.40 3 16
3 14 0.0 47 442 14.80 298 1949 3.82 / 41.35 3 111
Average= 4.13
(KJ/cycle)

Cycle 8 GMT 30/11/2024 14:21: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.0 15 285 14.81 349 1473 1.47 / 35.19 3 17
2 7 -0.2 36 80 14.86 314 373 1.85 / 35.56 3 18
3 14 0.0 47 440 14.82 300 1956 3.80 / 37.52 3 101
Average= 4.17
(KJ/cycle)

Cycle 7 GMT 30/11/2024 13:28: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.2 15 285 14.83 357 1509 1.51 / 31.37 3 19
2 7 -0.2 36 80 14.87 324 385 1.89 / 31.75 3 17
3 14 0.1 47 440 14.83 301 1964 3.86 / 33.72 3 114
Average= 4.21
(KJ/cycle)

Cycle 6 GMT 30/11/2024 12:34: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.5 15 285 14.84 359 1518 1.52 / 27.48 3 17
2 7 -0.1 36 80 14.89 327 390 1.91 / 27.87 3 11
3 14 0.1 47 437 14.85 307 1992 3.90 / 29.86 3 120
Average= 4.27
(KJ/cycle)

Cycle 5 GMT 30/11/2024 11:41: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.2 15 285 14.85 364 1541 1.54 / 23.56 3 19
2 7 -0.1 36 80 14.90 332 396 1.94 / 23.96 3 15
3 14 0.1 47 435 14.86 310 2004 3.94 / 25.96 3 113
Average= 4.33
(KJ/cycle)

Cycle 4 GMT 30/11/2024 10:45: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.4 15 285 14.85 365 1545 1.54 / 19.61 3 17
2 7 -0.2 36 80 14.89 334 398 1.94 / 20.00 3 18
3 14 0.0 47 435 14.85 312 2015 3.96 / 22.02 3 110
Average= 4.40
(KJ/cycle)

Cycle 3 GMT 30/11/2024 9:50: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 52.9 15 284 14.87 371 1567 1.57 / 15.62 3 18
2 7 -0.2 36 80 14.91 334 398 1.97 / 16.02 3 19
3 14 0.0 47 435 14.86 316 2043 4.01 / 18.06 3 107
Average= 4.52
(KJ/cycle)

Cycle 2 GMT 30/11/2024 8:54: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.4 15 284 14.96 374 1589 1.59 / 11.56 3 20
2 7 -0.2 36 80 14.96 339 406 1.99 / 11.97 3 21
3 14 0.0 47 435 14.90 322 2087 4.08 / 14.05 3 112
Average= 4.68
(KJ/cycle)

Cycle 1 GMT 30/11/2024 8: 1: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.2 15 284 15.14 388 1668 1.67 / 7.39 3 21
2 7 0.4 36 80 15.10 358 432 2.10 / 7.82 3 14
3 14 0.6 47 427 15.03 335 2150 4.25 / 9.97 3 114
Average= 4.99
(KJ/cycle)

Cycle 0 GMT 30/11/2024 7: 7:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 142.9 62729 407 15.43 476 2989 2.99 / 2.99 3 15
2 7 204.8 62731 80 15.32 478 586 3.58 / 3.58 3 21
3 13 176.8 62737 80 15.30 462 565 4.14 / 4.14 3 19
4 14 -0.3 62762 298 15.24 348 1580 5.72 / 5.72 3 103
Average= 5.72
(KJ/cycle)