SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 32 | 15.22 | 449 | 219 | 0.22 / 67.63 | 2 | 3 |
2 | 7 | 2007.52 | 38 | 14.94 | 2811 | 1596 | 1.81 / 69.23 | 2 | 4 |
3 | 13 | 1368.84 | 18 | 15.04 | 2051 | 555 | 2.37 / 69.78 | 2 | 7 |
4 | 13 | 876.72 | 18 | 15.11 | 1429 | 389 | 2.76 / 70.17 | 2 | 7 |
5 | 13 | 202.16 | 18 | 15.27 | 582 | 160 | 2.92 / 70.33 | 2 | 6 |
6 | 8 | -0.16 | 165 | 15.27 | 294 | 741 | 3.66 / 71.07 | 2 | 16 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 31 | 15.21 | 463 | 218 | 0.22 / 63.97 | 2 | 3 |
2 | 7 | 2003.72 | 38 | 14.96 | 2805 | 1595 | 1.81 / 65.57 | 2 | 4 |
3 | 13 | 1348.32 | 18 | 15.04 | 2029 | 549 | 2.36 / 66.12 | 2 | 5 |
4 | 13 | 907.40 | 18 | 15.13 | 1428 | 389 | 2.75 / 66.50 | 2 | 6 |
5 | 13 | 180.04 | 18 | 15.28 | 557 | 153 | 2.90 / 66.66 | 2 | 6 |
6 | 8 | 0.16 | 165 | 15.28 | 300 | 756 | 3.66 / 67.41 | 2 | 13 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 31 | 15.20 | 454 | 214 | 0.21 / 60.29 | 2 | 3 |
2 | 7 | 2005.76 | 38 | 14.94 | 2798 | 1588 | 1.80 / 61.88 | 2 | 5 |
3 | 13 | 1452.32 | 18 | 15.03 | 2150 | 582 | 2.38 / 62.46 | 2 | 8 |
4 | 13 | 831.32 | 18 | 15.13 | 1369 | 373 | 2.76 / 62.83 | 2 | 5 |
5 | 13 | 233.80 | 18 | 15.26 | 623 | 171 | 2.93 / 63.00 | 2 | 7 |
6 | 8 | 0.36 | 165 | 15.27 | 298 | 751 | 3.68 / 63.75 | 2 | 12 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 31 | 15.20 | 443 | 209 | 0.21 / 56.64 | 2 | 3 |
2 | 7 | 2005.80 | 38 | 14.94 | 2805 | 1592 | 1.80 / 58.23 | 2 | 4 |
3 | 13 | 1353.84 | 18 | 15.03 | 2024 | 548 | 2.35 / 58.78 | 2 | 6 |
4 | 13 | 836.32 | 18 | 15.12 | 1354 | 369 | 2.72 / 59.14 | 2 | 7 |
5 | 13 | 297.76 | 18 | 15.24 | 703 | 193 | 2.91 / 59.34 | 2 | 6 |
6 | 8 | 0.36 | 165 | 15.27 | 293 | 738 | 3.65 / 60.07 | 2 | 15 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 31 | 15.22 | 461 | 218 | 0.22 / 53.03 | 2 | 3 |
2 | 7 | 2003.24 | 38 | 14.93 | 2803 | 1590 | 1.81 / 54.62 | 2 | 4 |
3 | 13 | 1344.40 | 18 | 15.03 | 2021 | 547 | 2.35 / 55.17 | 2 | 7 |
4 | 13 | 824.48 | 18 | 15.12 | 1328 | 361 | 2.72 / 55.53 | 2 | 7 |
5 | 13 | 215.44 | 18 | 15.27 | 600 | 165 | 2.88 / 55.69 | 2 | 6 |
6 | 8 | 0.00 | 165 | 15.27 | 291 | 733 | 3.61 / 56.43 | 2 | 20 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 15.21 | 457 | 215 | 0.22 / 49.38 | 2 | 3 |
2 | 7 | 2010.12 | 38 | 14.94 | 2811 | 1596 | 1.81 / 50.97 | 2 | 4 |
3 | 13 | 1397.72 | 18 | 15.02 | 2080 | 562 | 2.37 / 51.53 | 2 | 5 |
4 | 13 | 850.28 | 18 | 15.11 | 1376 | 374 | 2.75 / 51.91 | 2 | 7 |
5 | 13 | 220.60 | 18 | 15.27 | 602 | 165 | 2.91 / 52.07 | 2 | 6 |
6 | 8 | 0.28 | 165 | 15.28 | 293 | 739 | 3.65 / 52.81 | 2 | 15 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 31 | 15.21 | 446 | 210 | 0.21 / 45.74 | 2 | 3 |
2 | 7 | 2003.16 | 38 | 14.95 | 2800 | 1591 | 1.80 / 47.33 | 2 | 6 |
3 | 13 | 1341.32 | 18 | 15.04 | 2018 | 546 | 2.35 / 47.88 | 2 | 5 |
4 | 13 | 824.08 | 18 | 15.14 | 1324 | 361 | 2.71 / 48.24 | 2 | 6 |
5 | 13 | 241.00 | 18 | 15.25 | 622 | 171 | 2.88 / 48.41 | 2 | 7 |
6 | 8 | 0.20 | 165 | 15.27 | 297 | 748 | 3.63 / 49.16 | 2 | 20 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 31 | 15.22 | 438 | 207 | 0.21 / 42.12 | 2 | 3 |
2 | 7 | 2009.12 | 38 | 14.93 | 2801 | 1589 | 1.80 / 43.71 | 2 | 4 |
3 | 13 | 1391.80 | 18 | 15.03 | 2084 | 564 | 2.36 / 44.28 | 2 | 8 |
4 | 13 | 820.20 | 18 | 15.13 | 1322 | 360 | 2.72 / 44.64 | 2 | 7 |
5 | 13 | 228.88 | 18 | 15.26 | 614 | 169 | 2.89 / 44.80 | 2 | 5 |
6 | 8 | 0.08 | 165 | 15.28 | 289 | 729 | 3.62 / 45.53 | 2 | 15 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 31 | 15.22 | 449 | 212 | 0.21 / 38.48 | 2 | 3 |
2 | 7 | 2011.72 | 39 | 14.95 | 2812 | 1640 | 1.85 / 40.12 | 2 | 4 |
3 | 13 | 1318.04 | 18 | 15.05 | 1988 | 539 | 2.39 / 40.66 | 2 | 6 |
4 | 13 | 879.72 | 18 | 15.12 | 1403 | 382 | 2.77 / 41.04 | 2 | 7 |
5 | 13 | 204.56 | 18 | 15.28 | 568 | 156 | 2.93 / 41.20 | 2 | 5 |
6 | 8 | 0.32 | 165 | 15.29 | 285 | 719 | 3.65 / 41.92 | 2 | 15 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 31 | 15.24 | 446 | 211 | 0.21 / 34.88 | 2 | 3 |
2 | 3 | 1020.32 | 1 | 15.28 | 1624 | 25 | 0.24 / 34.90 | 2 | 5 |
3 | 7 | 2008.16 | 38 | 14.96 | 2794 | 1588 | 1.82 / 36.49 | 2 | 7 |
4 | 13 | 1278.48 | 18 | 15.05 | 1922 | 521 | 2.34 / 37.01 | 2 | 5 |
5 | 13 | 845.80 | 18 | 15.15 | 1356 | 370 | 2.71 / 37.38 | 2 | 7 |
6 | 13 | 212.12 | 18 | 15.28 | 587 | 161 | 2.88 / 37.55 | 2 | 5 |
7 | 8 | 0.16 | 165 | 15.29 | 287 | 724 | 3.60 / 38.27 | 2 | 18 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 31 | 15.24 | 440 | 208 | 0.21 / 31.29 | 2 | 3 |
2 | 7 | 2008.52 | 38 | 14.97 | 2807 | 1597 | 1.80 / 32.89 | 2 | 4 |
3 | 13 | 1310.52 | 18 | 15.07 | 1965 | 533 | 2.34 / 33.42 | 2 | 7 |
4 | 13 | 831.64 | 18 | 15.15 | 1357 | 370 | 2.71 / 33.79 | 2 | 6 |
5 | 13 | 207.48 | 18 | 15.29 | 576 | 159 | 2.87 / 33.95 | 2 | 7 |
6 | 8 | 0.04 | 165 | 15.31 | 286 | 722 | 3.59 / 34.67 | 2 | 17 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 31 | 15.23 | 457 | 216 | 0.22 / 27.01 | 2 | 3 |
2 | 7 | 2002.40 | 74 | 14.85 | 2791 | 3067 | 3.28 / 30.07 | 2 | 4 |
3 | 13 | 586.64 | 18 | 15.20 | 1033 | 283 | 3.57 / 30.36 | 2 | 5 |
4 | 8 | 0.00 | 165 | 15.31 | 287 | 725 | 4.29 / 31.08 | 2 | 16 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 30 | 15.24 | 455 | 208 | 0.21 / 22.95 | 2 | 3 |
2 | 7 | 1812.92 | 74 | 14.91 | 2564 | 2829 | 3.04 / 25.78 | 2 | 3 |
3 | 13 | 549.44 | 18 | 15.20 | 997 | 273 | 3.31 / 26.06 | 2 | 5 |
4 | 8 | 0.20 | 165 | 15.30 | 291 | 735 | 4.04 / 26.79 | 2 | 15 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 29 | 15.24 | 442 | 195 | 0.20 / 18.93 | 2 | 3 |
2 | 3 | 1026.24 | 1 | 15.29 | 1675 | 26 | 0.22 / 18.96 | 2 | 2 |
3 | 7 | 1811.36 | 74 | 14.91 | 2563 | 2828 | 3.05 / 21.78 | 2 | 4 |
4 | 13 | 431.88 | 18 | 15.24 | 859 | 236 | 3.28 / 22.02 | 2 | 6 |
5 | 8 | 0.20 | 165 | 15.30 | 288 | 727 | 4.01 / 22.75 | 2 | 18 |
Average= | 3.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 29 | 15.25 | 442 | 195 | 0.20 / 14.96 | 2 | 3 |
2 | 7 | 1810.48 | 74 | 14.91 | 2562 | 2827 | 3.02 / 17.78 | 2 | 4 |
3 | 13 | 410.28 | 18 | 15.24 | 822 | 225 | 3.25 / 18.01 | 2 | 5 |
4 | 8 | 0.08 | 165 | 15.30 | 288 | 727 | 3.97 / 18.73 | 2 | 18 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 29 | 15.26 | 437 | 193 | 0.19 / 11.38 | 2 | 3 |
2 | 3 | 1018.52 | 1 | 15.32 | 1574 | 24 | 0.22 / 11.41 | 2 | 2 |
3 | 7 | 1524.60 | 74 | 15.02 | 2211 | 2457 | 2.67 / 13.86 | 2 | 4 |
4 | 13 | 291.00 | 18 | 15.30 | 673 | 185 | 2.86 / 14.05 | 2 | 6 |
5 | 8 | -0.04 | 165 | 15.32 | 281 | 710 | 3.57 / 14.76 | 2 | 14 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 26 | 15.27 | 432 | 172 | 0.17 / 7.73 | 2 | 3 |
2 | 10 | 1019.28 | 3 | 15.23 | 1602 | 73 | 0.24 / 7.81 | 2 | 3 |
3 | 3 | 1020.20 | 1 | 15.30 | 1663 | 25 | 0.27 / 7.83 | 2 | 2 |
4 | 7 | 1526.92 | 74 | 15.02 | 2216 | 2463 | 2.73 / 10.30 | 2 | 4 |
5 | 13 | 312.88 | 18 | 15.29 | 700 | 193 | 2.93 / 10.49 | 2 | 5 |
6 | 8 | 0.08 | 165 | 15.33 | 277 | 701 | 3.63 / 11.19 | 2 | 14 |
Average= | 2.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 33 | 15.33 | 429 | 217 | 0.22 / 4.23 | 2 | 3 |
2 | 3 | 844.00 | -3 | 15.65 | 0 | 0 | 0.00 / 4.23 | 2 | 3 |
3 | 3 | 909.08 | -2 | 15.66 | 0 | 0 | 0.00 / 4.23 | 2 | 3 |
4 | 7 | 1526.20 | 74 | 15.03 | 2204 | 2451 | 2.67 / 6.68 | 2 | 4 |
5 | 13 | 316.20 | 18 | 15.29 | 700 | 193 | 2.86 / 6.87 | 2 | 6 |
6 | 8 | 0.20 | 165 | 15.33 | 273 | 691 | 3.55 / 7.56 | 2 | 16 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 28 | 15.48 | 380 | 165 | 0.16 / 1.58 | 3 | 3 |
2 | 7 | 1012.56 | 74 | 15.21 | 1546 | 1740 | 1.90 / 3.32 | 2 | 7 |
3 | 8 | -0.04 | 165 | 15.40 | 273 | 694 | 2.60 / 4.01 | 2 | 19 |
Average= | 2.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 89.04 | 28 | 15.62 | 352 | 154 | 0.15 / 0.15 | 3 | 3 |
2 | 7 | 102.88 | 74 | 15.59 | 369 | 426 | 0.58 / 0.58 | 3 | 3 |
3 | 8 | 0.64 | 240 | 15.56 | 223 | 833 | 1.41 / 1.41 | 3 | 23 |
Average= | 1.41 (KJ/cycle) |