SIO Argo Site:
Pump Diagnostics Page   



Serial= 3175 WMO= 7900805

Return

←PreviousNext→

Cycle 77 GMT 13/12/2024 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 28 15.09 509 215 0.22 / 290.18 2 11
2 7 2006.24 38 14.69 2948 1646 1.86 / 291.82 2 7
3 13 1298.32 18 14.84 2089 558 2.42 / 292.38 2 11
4 13 751.20 18 14.96 1383 372 2.79 / 292.75 2 14
5 13 210.44 10 15.15 669 101 2.89 / 292.85 2 16
6 8 0.44 165 15.16 343 858 3.75 / 293.71 2 24
Average= 3.77
(KJ/cycle)

Cycle 76 GMT 3/12/2024 14:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 15.10 505 214 0.21 / 286.36 2 11
2 7 2005.92 39 14.69 2951 1691 1.90 / 288.05 2 7
3 13 1292.80 18 14.85 2078 555 2.46 / 288.60 2 11
4 13 796.40 18 14.95 1437 387 2.85 / 288.99 2 13
5 13 252.88 11 15.14 714 119 2.97 / 289.11 2 15
6 8 0.24 165 15.16 341 853 3.82 / 289.96 2 17
Average= 3.77
(KJ/cycle)

Cycle 75 GMT 23/11/2024 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 15.12 501 212 0.21 / 282.63 2 12
2 7 2007.72 38 14.70 2948 1647 1.86 / 284.28 2 7
3 13 1218.80 18 14.86 1979 529 2.39 / 284.81 2 11
4 13 745.40 18 14.98 1362 367 2.76 / 285.18 2 13
5 13 249.00 11 15.14 717 119 2.87 / 285.30 2 15
6 8 -0.32 165 15.17 339 849 3.72 / 286.14 2 23
Average= 3.77
(KJ/cycle)

Cycle 74 GMT 13/11/2024 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.11 513 217 0.22 / 278.86 2 14
2 7 2004.92 38 14.70 2947 1646 1.86 / 280.51 2 8
3 13 1315.92 18 14.85 2101 562 2.42 / 281.07 2 11
4 13 775.84 18 14.98 1413 381 2.81 / 281.45 2 13
5 13 240.60 11 15.16 699 117 2.92 / 281.57 2 15
6 8 0.12 165 15.18 341 854 3.78 / 282.42 2 16
Average= 3.77
(KJ/cycle)

Cycle 73 GMT 4/11/2024 4:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 28 15.12 499 211 0.21 / 275.08 2 12
2 7 2004.96 38 14.70 2943 1644 1.86 / 276.72 2 7
3 13 1296.68 18 14.86 2072 554 2.41 / 277.28 2 11
4 13 792.48 18 14.98 1428 385 2.79 / 277.66 2 13
5 13 245.48 11 15.15 722 120 2.91 / 277.78 2 16
6 8 0.44 165 15.17 344 861 3.78 / 278.64 2 20
Average= 3.77
(KJ/cycle)

Cycle 72 GMT 25/10/2024 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.12 519 220 0.22 / 271.34 2 14
2 7 2004.56 38 14.71 2943 1645 1.86 / 272.99 2 7
3 13 1308.80 18 14.85 2098 561 2.43 / 273.55 2 11
4 13 753.40 18 15.00 1373 371 2.80 / 273.92 2 13
5 13 239.28 10 15.17 690 105 2.90 / 274.03 2 16
6 8 0.08 165 15.19 336 842 3.74 / 274.87 2 24
Average= 3.77
(KJ/cycle)

Cycle 71 GMT 15/10/2024 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 28 15.11 519 220 0.22 / 267.58 2 13
2 7 2005.28 38 14.71 2947 1647 1.87 / 269.23 2 8
3 13 1287.16 18 14.87 2084 558 2.42 / 269.79 2 10
4 13 727.68 18 15.01 1346 364 2.79 / 270.15 2 14
5 13 242.88 11 15.15 720 120 2.91 / 270.27 2 15
6 8 -0.16 165 15.20 341 855 3.76 / 271.12 2 21
Average= 3.77
(KJ/cycle)

Cycle 70 GMT 5/10/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 15.14 501 212 0.21 / 263.74 2 12
2 7 2004.96 38 14.71 2939 1643 1.86 / 265.38 2 8
3 13 1380.08 18 14.84 2186 584 2.44 / 265.97 2 11
4 13 755.28 18 15.01 1380 373 2.81 / 266.34 2 13
5 13 351.48 14 15.12 841 178 2.99 / 266.52 2 15
6 8 0.28 165 15.19 337 845 3.83 / 267.36 2 27
Average= 3.77
(KJ/cycle)

Cycle 69 GMT 25/ 9/2024 22:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 28 15.13 512 217 0.22 / 259.98 2 14
2 7 2008.64 38 14.71 2950 1649 1.87 / 261.63 2 7
3 13 1289.92 18 14.88 2073 555 2.42 / 262.19 2 10
4 13 748.16 18 15.02 1379 373 2.79 / 262.56 2 13
5 13 255.32 11 15.16 723 121 2.91 / 262.68 2 16
6 8 0.32 165 15.20 337 845 3.76 / 263.53 2 22
Average= 3.76
(KJ/cycle)

Cycle 68 GMT 16/ 9/2024 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 15.13 509 216 0.22 / 256.25 2 13
2 7 2003.72 38 14.70 2944 1645 1.86 / 257.90 2 8
3 13 1293.28 18 14.87 2081 557 2.42 / 258.45 2 11
4 13 716.04 18 15.02 1337 361 2.78 / 258.81 2 13
5 13 228.32 10 15.18 691 105 2.88 / 258.92 2 16
6 8 0.00 165 15.20 338 848 3.73 / 259.77 2 17
Average= 3.76
(KJ/cycle)

Cycle 67 GMT 6/ 9/2024 7:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 27 15.12 509 208 0.21 / 252.50 2 13
2 3 1017.84 1 15.09 1778 27 0.23 / 252.52 2 8
3 7 2002.08 38 14.70 2935 1639 1.87 / 254.16 2 8
4 13 1234.08 18 14.91 2005 538 2.41 / 254.70 2 11
5 13 711.88 18 15.03 1330 360 2.77 / 255.06 2 14
6 13 258.16 11 15.18 719 120 2.89 / 255.18 2 16
7 8 0.12 165 15.21 340 853 3.75 / 256.04 2 14
Average= 3.77
(KJ/cycle)

Cycle 66 GMT 27/ 8/2024 12: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 15.16 499 204 0.20 / 248.68 2 13
2 10 1001.12 2 15.05 1750 53 0.26 / 248.73 2 10
3 3 958.84 -1 15.48 1 0 0.05 / 248.73 2 10
4 7 2003.16 38 14.70 2952 1649 1.91 / 250.38 2 8
5 13 1299.72 18 14.85 2083 557 2.46 / 250.94 2 11
6 13 768.28 18 14.98 1408 380 2.84 / 251.32 2 14
7 13 268.16 11 15.15 733 122 2.96 / 251.44 2 16
8 8 0.08 165 15.19 340 852 3.82 / 252.29 2 18
Average= 3.77
(KJ/cycle)

Cycle 65 GMT 17/ 8/2024 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 27 15.15 502 205 0.21 / 244.97 2 15
2 7 2003.20 38 14.71 2935 1641 1.85 / 246.61 2 8
3 13 1247.20 18 14.90 2018 541 2.39 / 247.15 2 11
4 13 762.96 18 15.03 1400 379 2.77 / 247.53 2 13
5 13 189.80 9 15.21 631 86 2.85 / 247.62 2 17
6 8 -0.12 165 15.22 340 854 3.71 / 248.47 2 19
Average= 3.76
(KJ/cycle)

Cycle 64 GMT 7/ 8/2024 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 26 15.14 519 204 0.20 / 241.23 2 15
2 3 1038.88 1 15.05 1814 27 0.23 / 241.26 2 11
3 7 2002.84 38 14.71 2953 1651 1.88 / 242.91 2 7
4 13 1300.28 18 14.88 2088 559 2.44 / 243.47 2 11
5 13 711.00 18 15.02 1330 360 2.80 / 243.83 2 13
6 13 207.24 10 15.20 651 99 2.90 / 243.92 2 15
7 8 0.36 165 15.21 336 843 3.74 / 244.77 2 19
Average= 3.77
(KJ/cycle)

Cycle 63 GMT 29/ 7/2024 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 26 15.14 498 196 0.20 / 237.54 2 13
2 7 2004.16 38 14.70 2943 1644 1.84 / 239.18 2 8
3 13 1245.72 18 14.89 2021 542 2.38 / 239.72 2 11
4 13 679.40 18 15.05 1287 349 2.73 / 240.07 2 14
5 13 193.92 9 15.21 643 88 2.82 / 240.16 2 16
6 8 0.00 165 15.21 344 863 3.68 / 241.02 2 20
Average= 3.77
(KJ/cycle)

Cycle 62 GMT 19/ 7/2024 6: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 27 15.15 497 203 0.20 / 233.69 2 13
2 3 932.00 -2 15.49 0 0 0.00 / 233.69 2 13
3 7 2003.28 38 14.72 2944 1647 1.85 / 235.34 2 8
4 13 1313.84 18 14.89 2103 564 2.41 / 235.90 2 10
5 13 754.32 18 15.02 1390 376 2.79 / 236.28 2 14
6 13 164.72 8 15.22 586 71 2.86 / 236.35 2 16
7 13 83.92 6 15.25 479 44 2.90 / 236.39 2 16
8 13 20.00 18 15.26 377 104 3.01 / 236.49 2 17
9 8 0.20 165 15.21 338 848 3.86 / 237.34 2 25
Average= 3.77
(KJ/cycle)

Cycle 61 GMT 9/ 7/2024 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 27 15.16 512 210 0.21 / 229.95 2 13
2 3 1018.92 1 15.08 1805 27 0.24 / 229.98 2 9
3 7 2006.28 38 14.72 2950 1650 1.89 / 231.63 2 8
4 13 1256.88 18 14.90 2032 545 2.43 / 232.17 2 11
5 13 775.76 18 15.02 1414 382 2.81 / 232.55 2 14
6 13 184.44 9 15.23 624 86 2.90 / 232.64 2 16
7 8 -0.20 165 15.22 337 846 3.75 / 233.49 2 23
Average= 3.77
(KJ/cycle)

Cycle 60 GMT 29/ 6/2024 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 27 15.14 489 200 0.20 / 226.24 2 14
2 3 977.24 -1 15.49 0 0 0.00 / 226.24 2 14
3 7 2004.16 38 14.71 2946 1647 1.85 / 227.88 2 8
4 13 1248.92 18 14.90 2024 543 2.39 / 228.43 2 11
5 13 753.60 18 15.02 1386 375 2.76 / 228.80 2 13
6 13 203.96 9 15.20 645 88 2.85 / 228.89 2 16
7 8 0.20 165 15.21 339 851 3.70 / 229.74 2 22
Average= 3.77
(KJ/cycle)

Cycle 59 GMT 19/ 6/2024 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 15.16 492 209 0.21 / 222.43 2 13
2 7 2008.60 38 14.72 2948 1649 1.86 / 224.08 2 7
3 13 1293.36 18 14.90 2074 556 2.41 / 224.63 2 11
4 13 746.92 18 15.03 1371 371 2.78 / 225.00 2 14
5 13 201.80 9 15.21 645 88 2.87 / 225.09 2 16
6 13 17.60 18 15.26 366 101 2.97 / 225.19 2 13
7 8 0.24 165 15.21 336 843 3.82 / 226.04 2 17
Average= 3.77
(KJ/cycle)

Cycle 58 GMT 10/ 6/2024 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.19 496 211 0.21 / 218.68 2 13
2 7 2002.56 38 14.73 2939 1645 1.86 / 220.32 2 8
3 13 1298.36 18 14.91 2085 560 2.42 / 220.88 2 11
4 13 723.28 18 15.05 1342 364 2.78 / 221.24 2 14
5 13 276.52 12 15.21 740 135 2.91 / 221.38 2 16
6 8 0.08 165 15.24 334 840 3.75 / 222.22 2 20
Average= 3.77
(KJ/cycle)

Cycle 57 GMT 31/ 5/2024 4:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 28 15.17 513 218 0.22 / 214.93 2 14
2 7 2004.64 38 14.73 2945 1648 1.87 / 216.58 2 8
3 13 1288.52 18 14.91 2067 555 2.42 / 217.13 2 11
4 13 785.08 18 15.02 1429 386 2.81 / 217.52 2 13
5 13 230.48 10 15.21 683 104 2.91 / 217.62 2 16
6 8 0.28 165 15.24 335 842 3.75 / 218.47 2 20
Average= 3.77
(KJ/cycle)

Cycle 56 GMT 21/ 5/2024 9:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 28 15.17 479 203 0.20 / 211.20 2 12
2 7 2002.68 38 14.73 2937 1644 1.85 / 212.84 2 8
3 13 1322.92 18 14.89 2116 567 2.41 / 213.41 2 11
4 13 698.04 18 15.05 1322 358 2.77 / 213.76 2 13
5 13 215.48 10 15.22 675 103 2.88 / 213.87 2 16
6 8 0.88 165 15.23 336 844 3.72 / 214.71 2 18
Average= 3.77
(KJ/cycle)

Cycle 55 GMT 11/ 5/2024 13:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.18 492 209 0.21 / 207.30 2 12
2 7 2003.36 38 14.74 2938 1646 1.85 / 208.95 2 8
3 13 1293.16 18 14.91 2065 554 2.41 / 209.50 2 11
4 13 749.60 18 15.05 1388 376 2.78 / 209.88 2 14
5 13 205.64 10 15.23 649 99 2.88 / 209.98 2 15
6 13 45.08 5 15.28 418 32 2.92 / 210.01 2 14
7 8 1.40 165 15.24 330 830 3.75 / 210.84 2 24
8 14 1.40 30 15.22 331 151 3.90 / 210.99 2 22
Average= 3.77
(KJ/cycle)

Cycle 54 GMT 1/ 5/2024 18:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.17 496 211 0.21 / 203.52 2 12
2 7 2004.24 38 14.73 2941 1646 1.86 / 205.16 2 8
3 13 1240.52 18 14.93 2012 541 2.40 / 205.71 2 12
4 13 713.64 18 15.06 1325 359 2.76 / 206.06 2 14
5 13 211.08 10 15.23 652 99 2.86 / 206.16 2 16
6 13 17.08 18 15.29 361 99 2.96 / 206.26 2 17
7 8 0.12 165 15.24 331 832 3.79 / 207.10 2 21
Average= 3.77
(KJ/cycle)

Cycle 53 GMT 21/ 4/2024 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 15.18 497 211 0.21 / 199.77 2 12
2 7 2003.48 39 14.73 2937 1687 1.90 / 201.46 2 8
3 13 1286.88 18 14.92 2065 555 2.45 / 202.02 2 11
4 13 744.44 18 15.05 1373 372 2.82 / 202.39 2 14
5 13 202.76 9 15.23 635 87 2.91 / 202.47 2 16
6 8 0.16 165 15.25 331 833 3.74 / 203.31 2 24
Average= 3.76
(KJ/cycle)

Cycle 52 GMT 12/ 4/2024 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 15.18 490 208 0.21 / 195.99 2 13
2 7 2009.28 38 14.75 2954 1656 1.86 / 197.65 2 8
3 13 1313.40 18 14.92 2112 567 2.43 / 198.21 2 11
4 13 778.88 18 15.04 1414 383 2.81 / 198.60 2 14
5 13 276.24 12 15.21 742 135 2.95 / 198.73 2 16
6 8 0.04 165 15.25 330 830 3.78 / 199.56 2 21
Average= 3.77
(KJ/cycle)

Cycle 51 GMT 2/ 4/2024 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.19 497 211 0.21 / 192.19 2 11
2 7 2005.40 38 14.75 2951 1654 1.87 / 193.84 2 8
3 13 1315.92 18 14.93 2102 565 2.43 / 194.41 2 11
4 13 786.36 18 15.06 1422 385 2.82 / 194.79 2 14
5 13 206.92 10 15.24 642 98 2.91 / 194.89 2 16
6 13 53.68 5 15.30 425 33 2.95 / 194.92 2 16
7 13 43.60 5 15.30 401 31 2.98 / 194.96 2 14
8 8 0.12 165 15.24 329 827 3.80 / 195.78 2 25
Average= 3.77
(KJ/cycle)

Cycle 50 GMT 23/ 3/2024 12:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 15.19 497 211 0.21 / 188.47 2 12
2 7 2003.84 38 14.76 2942 1650 1.86 / 190.12 2 8
3 13 1260.84 18 14.94 2039 548 2.41 / 190.67 2 11
4 13 743.88 18 15.07 1364 370 2.78 / 191.04 2 14
5 13 208.64 10 15.24 653 100 2.88 / 191.14 2 16
6 8 0.48 165 15.25 333 838 3.72 / 191.98 2 27
Average= 3.76
(KJ/cycle)

Cycle 49 GMT 13/ 3/2024 16:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 15.18 486 207 0.21 / 184.74 2 12
2 7 2005.20 39 14.74 2936 1688 1.89 / 186.43 2 8
3 13 1294.00 18 14.92 2075 557 2.45 / 186.99 2 11
4 13 716.00 18 15.07 1331 361 2.81 / 187.35 2 14
5 13 185.32 9 15.25 621 85 2.90 / 187.44 2 16
6 8 0.16 165 15.25 328 825 3.72 / 188.26 2 23
Average= 3.77
(KJ/cycle)

Cycle 48 GMT 3/ 3/2024 21:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 28 15.20 492 209 0.21 / 180.87 2 12
2 7 2002.64 39 14.75 2936 1689 1.90 / 182.56 2 8
3 13 1341.96 18 14.92 2144 576 2.47 / 183.13 2 11
4 13 741.52 18 15.06 1371 372 2.85 / 183.51 2 14
5 13 245.76 18 15.21 703 192 3.04 / 183.70 2 17
6 8 0.64 165 15.25 334 840 3.88 / 184.54 2 25
Average= 3.77
(KJ/cycle)

Cycle 47 GMT 23/ 2/2024 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 28 15.20 486 207 0.21 / 177.07 2 12
2 7 2007.92 38 14.76 2950 1655 1.86 / 178.72 2 8
3 13 1243.28 18 14.93 2018 542 2.40 / 179.26 2 12
4 13 788.28 18 15.05 1421 385 2.79 / 179.65 2 14
5 13 221.80 18 15.23 663 182 2.97 / 179.83 2 17
6 8 -0.28 165 15.26 329 828 3.80 / 180.66 2 22
Average= 3.76
(KJ/cycle)

Cycle 46 GMT 13/ 2/2024 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 28 15.20 507 216 0.22 / 173.29 2 12
2 7 2004.28 38 14.76 2937 1647 1.86 / 174.93 2 8
3 13 1313.88 18 14.94 2105 566 2.43 / 175.50 2 12
4 13 715.72 18 15.08 1333 362 2.79 / 175.86 2 14
5 13 174.36 18 15.26 598 164 2.96 / 176.03 2 17
6 8 0.00 165 15.27 331 834 3.79 / 176.86 2 16
Average= 3.76
(KJ/cycle)

Cycle 45 GMT 3/ 2/2024 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 27 15.19 498 204 0.20 / 169.53 2 13
2 7 2003.00 38 14.75 2944 1650 1.85 / 171.18 2 8
3 13 1337.12 18 14.92 2142 575 2.43 / 171.76 2 12
4 13 759.88 18 15.07 1393 378 2.81 / 172.13 2 14
5 13 214.84 10 15.24 655 100 2.91 / 172.23 2 16
6 8 0.12 165 15.26 333 838 3.75 / 173.07 2 18
Average= 3.76
(KJ/cycle)

Cycle 44 GMT 24/ 1/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 27 15.21 484 199 0.20 / 165.81 2 12
2 7 2003.96 38 14.76 2947 1653 1.85 / 167.46 2 8
3 13 1288.16 18 14.94 2062 555 2.41 / 168.02 2 12
4 13 734.04 18 15.07 1361 369 2.78 / 168.39 2 14
5 13 229.48 10 15.25 683 104 2.88 / 168.49 2 16
6 8 0.08 165 15.26 332 836 3.72 / 169.33 2 21
Average= 3.76
(KJ/cycle)

Cycle 43 GMT 14/ 1/2024 20:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 27 15.19 509 209 0.21 / 161.99 2 13
2 7 2003.36 39 14.76 2946 1696 1.90 / 163.69 2 8
3 13 1278.36 18 14.95 2055 553 2.46 / 164.24 2 12
4 13 694.92 18 15.09 1308 355 2.81 / 164.60 2 15
5 13 250.28 11 15.23 708 119 2.93 / 164.71 2 16
6 13 19.60 10 15.31 369 56 2.99 / 164.77 2 15
7 8 0.12 165 15.27 333 839 3.83 / 165.61 2 17
Average= 3.76
(KJ/cycle)

Cycle 42 GMT 5/ 1/2024 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 27 15.22 492 202 0.20 / 158.27 2 12
2 7 2005.08 38 14.76 2942 1650 1.85 / 159.92 2 9
3 13 1293.36 18 14.95 2078 559 2.41 / 160.48 2 11
4 13 748.32 18 15.08 1378 374 2.79 / 160.85 2 15
5 13 200.68 9 15.26 638 88 2.87 / 160.94 2 17
6 8 0.28 165 15.27 335 844 3.72 / 161.78 2 22
Average= 3.76
(KJ/cycle)

Cycle 41 GMT 26/12/2023 5:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 27 15.20 508 208 0.21 / 154.52 2 13
2 7 2008.04 38 14.77 2945 1653 1.86 / 156.17 2 9
3 13 1288.32 18 14.94 2076 558 2.42 / 156.73 2 11
4 13 747.08 18 15.08 1376 374 2.79 / 157.11 2 15
5 13 241.36 11 15.25 701 118 2.91 / 157.22 2 17
6 8 -0.08 165 15.28 334 842 3.75 / 158.07 2 22
Average= 3.76
(KJ/cycle)

Cycle 40 GMT 16/12/2023 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 27 15.20 514 211 0.21 / 150.79 2 15
2 7 2003.52 38 14.77 2934 1647 1.86 / 152.44 2 9
3 13 1330.32 18 14.94 2123 571 2.43 / 153.01 2 11
4 13 699.12 18 15.10 1311 356 2.78 / 153.37 2 15
5 13 216.12 10 15.25 673 103 2.89 / 153.47 2 17
6 8 0.00 165 15.27 335 844 3.73 / 154.31 2 22
Average= 3.76
(KJ/cycle)

Cycle 39 GMT 6/12/2023 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 27 15.21 492 202 0.20 / 147.08 2 13
2 7 2007.44 38 14.76 2947 1653 1.85 / 148.73 2 9
3 13 1237.56 18 14.97 2002 539 2.39 / 149.27 2 12
4 13 702.08 18 15.10 1315 357 2.75 / 149.63 2 14
5 13 212.56 10 15.25 665 101 2.85 / 149.73 2 17
6 8 0.28 165 15.27 338 852 3.70 / 150.58 2 22
Average= 3.76
(KJ/cycle)

Cycle 38 GMT 26/11/2023 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 27 15.22 508 209 0.21 / 143.42 2 14
2 7 2002.76 38 14.77 2925 1642 1.85 / 145.06 2 9
3 13 1204.52 18 14.96 1955 526 2.38 / 145.58 2 12
4 13 689.04 18 15.10 1301 354 2.73 / 145.94 2 15
5 13 206.76 10 15.24 654 100 2.83 / 146.04 2 17
6 8 0.16 165 15.27 333 839 3.67 / 146.88 2 20
Average= 3.77
(KJ/cycle)

Cycle 37 GMT 16/11/2023 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 15.22 504 207 0.21 / 139.69 2 15
2 7 2004.16 38 14.78 2948 1656 1.86 / 141.34 2 8
3 13 1269.20 18 14.97 2032 548 2.41 / 141.89 2 12
4 13 776.20 18 15.09 1404 381 2.79 / 142.27 2 14
5 13 214.56 10 15.27 657 100 2.89 / 142.37 2 17
6 8 0.32 165 15.28 331 835 3.73 / 143.21 2 23
Average= 3.77
(KJ/cycle)

Cycle 36 GMT 7/11/2023 3:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 15.22 482 198 0.20 / 135.80 2 14
2 7 2004.40 39 14.77 2942 1695 1.89 / 137.49 2 9
3 13 1388.08 18 14.96 2191 590 2.48 / 138.08 2 11
4 13 769.20 18 15.08 1388 377 2.86 / 138.46 2 15
5 13 221.52 10 15.26 670 102 2.96 / 138.56 2 16
6 13 17.20 18 15.32 357 98 3.06 / 138.66 2 16
7 8 0.16 165 15.27 326 821 3.88 / 139.48 2 25
Average= 3.77
(KJ/cycle)

Cycle 35 GMT 28/10/2023 8:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 27 15.22 508 209 0.21 / 132.08 2 15
2 7 2005.28 38 14.79 2941 1653 1.86 / 133.73 2 8
3 13 1272.16 18 14.99 2042 551 2.41 / 134.28 2 11
4 13 673.12 18 15.12 1274 347 2.76 / 134.63 2 15
5 13 172.12 9 15.29 593 82 2.84 / 134.71 2 17
6 13 60.28 5 15.33 437 33 2.87 / 134.75 2 18
7 13 52.32 5 15.33 417 32 2.91 / 134.78 2 18
8 8 0.48 165 15.29 326 822 3.73 / 135.60 2 18
Average= 3.77
(KJ/cycle)

Cycle 34 GMT 18/10/2023 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 27 15.23 503 207 0.21 / 128.41 2 15
2 7 2004.16 38 14.79 2931 1647 1.85 / 130.06 2 9
3 13 1264.24 18 14.97 2039 549 2.40 / 130.61 2 12
4 13 685.36 18 15.12 1282 349 2.75 / 130.96 2 15
5 13 189.84 9 15.29 619 85 2.84 / 131.04 2 17
6 8 -0.12 165 15.29 328 827 3.67 / 131.87 2 22
Average= 3.77
(KJ/cycle)

Cycle 33 GMT 8/10/2023 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 27 15.24 499 205 0.21 / 124.70 2 14
2 7 2007.96 38 14.77 2945 1653 1.86 / 126.36 2 8
3 13 1258.36 18 14.97 2031 547 2.41 / 126.90 2 12
4 13 682.12 18 15.11 1278 348 2.75 / 127.25 2 15
5 13 148.40 8 15.29 545 67 2.82 / 127.32 2 17
6 13 68.12 6 15.31 438 40 2.86 / 127.36 2 16
7 13 45.44 5 15.33 406 31 2.89 / 127.39 2 15
8 8 -0.08 165 15.28 324 817 3.71 / 128.21 2 20
Average= 3.77
(KJ/cycle)

Cycle 32 GMT 28/ 9/2023 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 27 15.24 502 207 0.21 / 121.00 2 15
2 7 2007.80 39 14.79 2949 1701 1.91 / 122.70 2 8
3 13 1244.04 18 14.98 2015 543 2.45 / 123.24 2 12
4 13 669.24 18 15.12 1269 345 2.80 / 123.59 2 15
5 13 181.12 9 15.28 608 84 2.88 / 123.67 2 17
6 8 0.00 165 15.30 327 826 3.71 / 124.50 2 26
Average= 3.77
(KJ/cycle)

Cycle 31 GMT 19/ 9/2023 2:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 27 15.22 499 205 0.21 / 117.30 2 15
2 7 2003.32 39 14.78 2934 1691 1.90 / 118.99 2 9
3 13 1242.28 18 14.99 2003 540 2.44 / 119.53 2 12
4 13 701.20 18 15.12 1306 355 2.79 / 119.88 2 15
5 13 194.76 9 15.29 617 85 2.88 / 119.97 2 17
6 8 -0.24 165 15.30 326 823 3.70 / 120.79 2 21
Average= 3.77
(KJ/cycle)

Cycle 30 GMT 9/ 9/2023 6:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 27 15.23 496 204 0.20 / 113.58 2 13
2 7 2004.20 38 14.79 2942 1653 1.86 / 115.23 2 9
3 13 1287.32 18 14.97 2061 555 2.41 / 115.79 2 12
4 13 701.44 18 15.12 1309 356 2.77 / 116.14 2 15
5 13 193.52 9 15.28 624 86 2.85 / 116.23 2 17
6 13 40.40 5 15.33 403 31 2.89 / 116.26 2 16
7 8 0.24 165 15.29 330 833 3.72 / 117.09 2 18
Average= 3.78
(KJ/cycle)

Cycle 29 GMT 30/ 8/2023 11: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 15.24 496 204 0.20 / 109.90 2 13
2 7 2002.84 38 14.78 2935 1648 1.85 / 111.55 2 9
3 13 1238.76 18 14.99 1998 539 2.39 / 112.09 2 12
4 13 694.56 18 15.11 1297 353 2.74 / 112.44 2 15
5 13 236.76 10 15.26 693 106 2.85 / 112.55 2 17
6 8 0.08 165 15.29 328 827 3.68 / 113.37 2 21
Average= 3.78
(KJ/cycle)

Cycle 28 GMT 20/ 8/2023 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 27 15.23 514 211 0.21 / 106.18 2 15
2 7 2003.24 38 14.80 2933 1650 1.86 / 107.83 2 9
3 13 1243.88 18 15.00 2004 541 2.40 / 108.37 2 12
4 13 701.56 18 15.13 1311 357 2.76 / 108.72 2 15
5 13 195.36 9 15.30 627 86 2.85 / 108.81 2 17
6 13 52.24 5 15.35 418 32 2.88 / 108.84 2 17
7 13 18.56 5 15.35 366 28 2.91 / 108.87 2 16
8 8 0.12 165 15.30 327 826 3.73 / 109.70 2 23
Average= 3.78
(KJ/cycle)

Cycle 27 GMT 10/ 8/2023 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 27 15.25 504 208 0.21 / 102.48 2 14
2 7 2002.52 38 14.80 2945 1656 1.86 / 104.14 2 8
3 13 1236.20 18 15.00 2003 541 2.40 / 104.68 2 12
4 13 741.44 18 15.11 1368 372 2.78 / 105.05 2 15
5 13 174.36 9 15.29 597 82 2.86 / 105.13 2 17
6 8 0.48 165 15.30 330 833 3.69 / 105.97 2 19
Average= 3.78
(KJ/cycle)

Cycle 26 GMT 1/ 8/2023 0:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 27 15.24 491 202 0.20 / 98.85 2 14
2 7 2003.16 38 14.80 2941 1654 1.86 / 100.50 2 9
3 13 1170.88 18 15.02 1912 517 2.37 / 101.02 2 13
4 13 691.40 18 15.13 1300 354 2.73 / 101.37 2 14
5 13 148.56 8 15.31 553 68 2.79 / 101.44 2 17
6 8 -0.04 165 15.31 329 831 3.63 / 102.27 2 21
Average= 3.79
(KJ/cycle)

Cycle 25 GMT 22/ 7/2023 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 15.25 497 205 0.20 / 95.19 2 15
2 7 2003.36 38 14.80 2939 1653 1.86 / 96.84 2 9
3 13 1283.48 18 14.99 2054 554 2.41 / 97.40 2 12
4 13 688.04 18 15.13 1292 352 2.76 / 97.75 2 15
5 13 179.12 9 15.30 594 82 2.85 / 97.83 2 17
6 8 0.20 165 15.31 324 818 3.66 / 98.65 2 15
Average= 3.79
(KJ/cycle)

Cycle 24 GMT 12/ 7/2023 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 27 15.26 497 205 0.20 / 91.45 2 15
2 7 2003.40 39 14.82 2943 1701 1.91 / 93.15 2 9
3 13 1331.80 18 14.98 2126 573 2.48 / 93.72 2 12
4 13 647.92 18 15.16 1240 338 2.82 / 94.06 2 16
5 13 195.00 9 15.30 633 87 2.90 / 94.15 2 17
6 8 0.56 165 15.31 330 834 3.74 / 94.98 2 22
Average= 3.80
(KJ/cycle)

Cycle 23 GMT 2/ 7/2023 14: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 15.26 490 202 0.20 / 87.80 2 14
2 7 2007.20 38 14.82 2941 1656 1.86 / 89.45 2 9
3 13 1272.92 18 14.99 2038 550 2.41 / 90.00 2 13
4 13 653.08 18 15.15 1243 339 2.75 / 90.34 2 15
5 13 156.44 8 15.31 563 69 2.82 / 90.41 2 18
6 8 -0.32 165 15.31 330 834 3.65 / 91.25 2 25
Average= 3.80
(KJ/cycle)

Cycle 22 GMT 22/ 6/2023 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 27 15.24 504 207 0.21 / 84.15 2 14
2 7 2003.08 38 14.83 2933 1653 1.86 / 85.81 2 9
3 13 1239.52 18 15.02 1998 540 2.40 / 86.35 2 12
4 13 652.04 18 15.17 1249 341 2.74 / 86.69 2 15
5 13 200.52 9 15.30 634 87 2.83 / 86.77 2 17
6 8 0.36 165 15.32 325 822 3.65 / 87.60 2 20
Average= 3.81
(KJ/cycle)

Cycle 21 GMT 12/ 6/2023 22:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 27 15.25 500 206 0.21 / 80.40 2 15
2 7 2004.76 39 14.82 2941 1700 1.91 / 82.10 2 10
3 13 1293.32 18 15.00 2062 557 2.46 / 82.65 2 13
4 13 772.96 18 15.12 1403 382 2.84 / 83.03 2 15
5 13 199.92 9 15.30 632 87 2.93 / 83.12 2 17
6 8 0.16 165 15.31 326 824 3.75 / 83.95 2 21
Average= 3.82
(KJ/cycle)

Cycle 20 GMT 3/ 6/2023 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 27 15.26 514 212 0.21 / 76.75 2 14
2 7 2011.04 38 14.81 2949 1660 1.87 / 78.41 2 9
3 13 1262.84 18 15.01 2033 549 2.42 / 78.96 2 13
4 13 635.60 18 15.17 1228 335 2.76 / 79.30 2 16
5 13 131.80 7 15.33 546 59 2.81 / 79.36 2 18
6 8 0.36 165 15.32 330 834 3.65 / 80.19 2 21
Average= 3.82
(KJ/cycle)

Cycle 19 GMT 24/ 5/2023 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 27 15.27 492 203 0.20 / 73.03 2 14
2 3 980.44 -1 15.63 0 0 0.00 / 73.03 2 14
3 7 2002.88 39 14.84 2941 1702 1.90 / 74.73 2 8
4 13 1221.76 18 15.03 1982 536 2.44 / 75.26 2 12
5 13 656.84 18 15.17 1248 341 2.78 / 75.60 2 15
6 13 240.52 11 15.30 686 115 2.90 / 75.72 2 17
7 8 0.04 165 15.32 325 822 3.72 / 76.54 2 20
Average= 3.83
(KJ/cycle)

Cycle 18 GMT 14/ 5/2023 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 27 15.26 497 205 0.20 / 69.31 2 14
2 7 2002.28 38 14.84 2940 1658 1.86 / 70.96 2 9
3 13 1295.72 18 15.01 2071 560 2.42 / 71.52 2 12
4 13 688.08 18 15.16 1296 354 2.78 / 71.88 2 15
5 13 184.08 9 15.32 611 84 2.86 / 71.96 2 17
6 13 40.92 5 15.38 400 31 2.89 / 71.99 2 16
7 8 -0.16 165 15.32 329 832 3.72 / 72.82 2 23
Average= 3.83
(KJ/cycle)

Cycle 17 GMT 4/ 5/2023 17: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 27 15.27 493 203 0.20 / 65.58 2 14
2 7 2007.12 39 14.84 2943 1703 1.91 / 67.28 2 9
3 13 1265.00 18 15.02 2032 549 2.46 / 67.83 2 12
4 13 680.24 18 15.16 1282 350 2.81 / 68.18 2 15
5 13 180.00 9 15.32 609 84 2.89 / 68.27 2 17
6 8 0.72 165 15.33 329 832 3.72 / 69.10 2 20
Average= 3.84
(KJ/cycle)

Cycle 16 GMT 24/ 4/2023 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 27 15.27 479 197 0.20 / 61.90 2 13
2 7 2007.60 39 14.85 2943 1704 1.90 / 63.61 2 9
3 13 1251.16 18 15.03 2019 546 2.45 / 64.15 2 13
4 13 664.68 18 15.19 1247 341 2.79 / 64.49 2 15
5 13 122.36 7 15.35 523 56 2.85 / 64.55 2 17
6 8 -0.40 165 15.33 328 830 3.67 / 65.38 2 22
Average= 3.85
(KJ/cycle)

Cycle 15 GMT 15/ 4/2023 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 26 15.27 502 199 0.20 / 58.23 2 13
2 10 1003.64 2 15.16 1767 54 0.25 / 58.29 2 11
3 3 951.00 -2 15.60 0 0 0.05 / 58.29 2 11
4 7 2006.40 38 14.86 2946 1664 1.92 / 59.95 2 9
5 13 1159.20 18 15.07 1899 515 2.43 / 60.47 2 13
6 13 644.96 18 15.19 1240 339 2.77 / 60.80 2 15
7 13 152.24 8 15.34 564 69 2.84 / 60.87 2 17
8 8 0.84 165 15.34 328 830 3.67 / 61.70 2 19
Average= 3.86
(KJ/cycle)

Cycle 14 GMT 5/ 4/2023 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 26 15.27 489 194 0.19 / 54.58 2 13
2 7 2003.12 38 14.86 2944 1662 1.86 / 56.24 2 9
3 13 1237.84 18 15.04 2003 542 2.40 / 56.78 2 12
4 13 639.88 18 15.19 1235 338 2.74 / 57.12 2 15
5 13 104.04 7 15.36 503 54 2.79 / 57.17 2 18
6 13 47.00 5 15.38 409 31 2.82 / 57.20 2 16
7 8 1.12 165 15.33 328 830 3.65 / 58.03 2 19
Average= 3.87
(KJ/cycle)

Cycle 13 GMT 26/ 3/2023 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 26 15.28 482 191 0.19 / 50.92 2 13
2 7 2003.32 38 14.86 2940 1660 1.85 / 52.58 2 9
3 13 1310.04 18 15.02 2080 562 2.41 / 53.15 2 12
4 13 605.92 18 15.19 1188 325 2.74 / 53.47 2 16
5 13 180.72 9 15.32 605 83 2.82 / 53.56 2 17
6 8 -0.12 165 15.32 327 827 3.65 / 54.38 2 21
Average= 3.88
(KJ/cycle)

Cycle 12 GMT 16/ 3/2023 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 26 15.26 494 196 0.20 / 47.25 2 13
2 7 2007.28 38 14.85 2945 1662 1.86 / 48.91 2 8
3 13 1316.44 18 15.03 2089 565 2.42 / 49.47 2 12
4 13 682.28 18 15.16 1278 349 2.77 / 49.82 2 15
5 13 180.68 9 15.33 603 83 2.85 / 49.91 2 17
6 8 -0.04 165 15.33 327 827 3.68 / 50.73 2 20
Average= 3.90
(KJ/cycle)

Cycle 11 GMT 6/ 3/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 26 15.27 496 197 0.20 / 43.52 2 13
2 7 2005.00 39 14.86 2937 1702 1.90 / 45.22 2 8
3 13 1246.16 18 15.04 2009 544 2.44 / 45.76 2 13
4 13 623.56 18 15.19 1202 329 2.77 / 46.09 2 15
5 13 94.60 18 15.35 478 132 2.90 / 46.22 2 18
6 8 0.28 165 15.33 327 827 3.73 / 47.05 2 20
Average= 3.92
(KJ/cycle)

Cycle 10 GMT 24/ 2/2023 23:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 26 15.27 501 199 0.20 / 38.98 2 13
2 10 1003.48 2 15.17 1783 54 0.25 / 39.03 2 11
3 3 955.16 -1 15.65 1 0 0.05 / 39.03 2 11
4 7 2003.28 74 14.74 2927 3193 3.45 / 42.22 2 10
5 13 457.28 18 15.23 983 269 3.72 / 42.49 2 16
6 8 0.04 165 15.33 327 827 4.54 / 43.32 2 21
Average= 3.94
(KJ/cycle)

Cycle 9 GMT 15/ 2/2023 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 26 15.28 494 196 0.20 / 34.44 2 13
2 3 1024.96 1 15.24 1799 27 0.22 / 34.47 2 11
3 7 2005.24 74 14.76 2930 3200 3.42 / 37.67 2 10
4 13 481.92 18 15.23 1020 280 3.70 / 37.95 2 16
5 8 0.16 165 15.34 328 830 4.53 / 38.78 2 24
Average= 3.88
(KJ/cycle)

Cycle 8 GMT 5/ 2/2023 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 28 15.28 505 216 0.22 / 29.97 2 14
2 3 911.44 -2 15.64 0 0 0.00 / 29.97 2 14
3 7 2002.88 74 14.75 2923 3190 3.41 / 33.16 2 10
4 13 406.88 18 15.25 917 252 3.66 / 33.41 2 17
5 8 -0.04 165 15.34 329 833 4.49 / 34.24 2 23
Average= 3.80
(KJ/cycle)

Cycle 7 GMT 26/ 1/2023 7:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 26 15.28 482 191 0.19 / 25.86 2 14
2 7 1776.40 74 14.81 2653 2908 3.10 / 28.77 2 10
3 13 314.96 13 15.28 791 157 3.26 / 28.92 2 16
4 8 0.04 165 15.33 328 830 4.09 / 29.75 2 23
Average= 3.72
(KJ/cycle)

Cycle 6 GMT 25/ 1/2023 7: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 26 15.27 503 200 0.20 / 21.67 2 14
2 7 1785.40 74 14.80 2663 2917 3.12 / 24.59 2 10
3 13 401.92 18 15.24 909 249 3.37 / 24.84 2 16
4 8 0.16 165 15.33 329 832 4.20 / 25.67 2 22
Average= 3.67
(KJ/cycle)

Cycle 5 GMT 24/ 1/2023 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 25 15.25 505 193 0.19 / 17.48 2 13
2 3 1027.32 1 15.24 1824 28 0.22 / 17.51 2 12
3 7 1748.76 74 14.83 2621 2876 3.10 / 20.38 2 10
4 13 401.44 18 15.25 910 250 3.35 / 20.63 2 16
5 8 0.32 165 15.33 331 837 4.18 / 21.47 2 24
Average= 3.58
(KJ/cycle)

Cycle 4 GMT 23/ 1/2023 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 25 15.28 494 189 0.19 / 12.97 2 13
2 10 1008.84 2 15.17 1765 54 0.24 / 13.02 2 12
3 3 963.84 -1 15.65 1 0 0.05 / 13.02 2 12
4 7 1767.96 74 14.82 2640 2895 3.14 / 15.92 2 11
5 13 328.04 13 15.29 811 161 3.30 / 16.08 2 17
6 8 0.32 165 15.33 328 830 4.13 / 16.91 2 23
7 14 0.32 75 15.29 327 375 4.50 / 17.29 2 25
Average= 3.46
(KJ/cycle)

Cycle 3 GMT 22/ 1/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 23 15.30 513 181 0.18 / 8.77 2 13
2 10 1034.20 2 15.17 1807 55 0.24 / 8.82 2 11
3 7 1774.84 74 14.83 2653 2911 3.15 / 11.74 2 10
4 13 281.76 18 15.30 740 204 3.35 / 11.94 2 17
5 8 0.12 165 15.34 333 843 4.19 / 12.78 2 24
Average= 3.20
(KJ/cycle)

Cycle 2 GMT 21/ 1/2023 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 31 15.34 504 240 0.24 / 4.97 2 14
2 3 784.20 -4 15.70 0 0 0.00 / 4.97 2 14
3 3 905.04 -2 15.72 0 0 0.00 / 4.97 2 14
4 7 1510.16 74 14.93 2327 2571 2.81 / 7.55 2 13
5 13 272.24 18 15.32 733 202 3.01 / 7.75 2 16
6 8 0.00 165 15.36 332 841 3.85 / 8.59 2 24
Average= 2.86
(KJ/cycle)

Cycle 1 GMT 20/ 1/2023 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 26 15.51 453 183 0.18 / 2.02 2 6
2 3 951.44 -1 15.72 0 0 0.00 / 2.02 2 6
3 7 992.08 74 15.14 1664 1864 2.05 / 3.89 2 14
4 8 0.08 165 15.42 333 847 2.89 / 4.73 2 19
Average= 2.37
(KJ/cycle)

Cycle 0 GMT 19/ 1/2023 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 145.60 25 15.66 500 196 0.20 / 0.20 2 5
2 7 161.28 74 15.60 518 598 0.79 / 0.79 2 7
3 8 0.08 240 15.58 280 1047 1.84 / 1.84 2 25
Average= 1.84
(KJ/cycle)