SIO Argo Site:
Pump Diagnostics Page   



Serial= 3174 WMO= 5906913

Return

←PreviousNext→

Cycle 76 GMT 2/12/2024 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 26 15.05 520 203 0.20 / 294.79 2 14
2 3 1018.72 1 15.06 1789 27 0.23 / 294.82 2 12
3 7 2005.44 38 14.79 2909 1635 1.87 / 296.46 2 11
4 13 1258.68 18 14.88 2027 543 2.41 / 297.00 2 14
5 13 773.76 18 14.95 1413 380 2.79 / 297.38 2 16
6 13 232.92 18 15.08 705 191 2.98 / 297.57 2 18
7 8 0.12 165 15.09 366 911 3.89 / 298.48 2 25
Average= 3.88
(KJ/cycle)

Cycle 75 GMT 22/11/2024 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 27 15.06 527 214 0.21 / 290.91 2 14
2 3 976.76 -1 15.37 0 0 0.00 / 290.91 2 14
3 7 2008.80 38 14.78 2919 1639 1.85 / 292.55 2 11
4 13 1353.00 18 14.87 2165 579 2.43 / 293.13 2 14
5 13 796.00 18 14.96 1456 392 2.83 / 293.52 2 17
6 13 189.92 18 15.11 640 174 3.00 / 293.69 2 20
7 8 0.04 165 15.10 360 897 3.90 / 294.59 2 22
Average= 3.88
(KJ/cycle)

Cycle 74 GMT 12/11/2024 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 26 15.05 506 198 0.20 / 286.98 2 14
2 3 1043.12 1 15.03 1816 27 0.23 / 287.01 2 13
3 7 2007.96 38 14.80 2925 1645 1.87 / 288.65 2 10
4 13 1322.64 18 14.87 2124 569 2.44 / 289.22 2 14
5 13 747.84 18 14.97 1390 375 2.81 / 289.60 2 17
6 13 229.28 18 15.10 701 191 3.00 / 289.79 2 20
7 8 0.08 165 15.10 364 907 3.91 / 290.69 2 19
Average= 3.88
(KJ/cycle)

Cycle 73 GMT 2/11/2024 23:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 15.05 509 214 0.21 / 283.14 2 18
2 3 946.68 -1 15.38 0 0 0.00 / 283.14 2 18
3 3 974.84 -1 15.43 0 0 0.00 / 283.14 2 18
4 7 2006.16 38 14.79 2924 1643 1.86 / 284.78 2 11
5 13 1265.56 18 14.89 2052 550 2.41 / 285.33 2 14
6 13 747.24 18 14.97 1389 374 2.78 / 285.71 2 17
7 13 173.64 18 15.11 622 169 2.95 / 285.87 2 17
8 8 0.40 165 15.11 365 910 3.86 / 286.78 2 21
Average= 3.88
(KJ/cycle)

Cycle 72 GMT 24/10/2024 4:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 15.05 522 212 0.21 / 279.05 2 17
2 3 1025.32 1 15.04 1785 27 0.24 / 279.07 2 12
3 7 2010.76 38 14.81 2926 1647 1.89 / 280.72 2 10
4 13 1310.36 18 14.88 2107 564 2.45 / 281.29 2 13
5 13 826.64 18 14.96 1474 397 2.85 / 281.68 2 16
6 13 239.80 18 15.10 701 191 3.04 / 281.87 2 18
7 8 0.44 165 15.11 357 890 3.93 / 282.76 2 20
8 14 0.44 30 15.09 354 160 4.09 / 282.92 2 22
Average= 3.88
(KJ/cycle)

Cycle 71 GMT 14/10/2024 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 15.06 526 214 0.21 / 275.25 2 18
2 7 2008.40 38 14.79 2901 1630 1.84 / 276.88 2 11
3 13 1272.12 18 14.88 2049 549 2.39 / 277.42 2 14
4 13 713.28 18 14.98 1334 360 2.75 / 277.78 2 17
5 13 145.04 18 15.12 576 157 2.91 / 277.94 2 16
6 8 0.04 165 15.10 359 894 3.80 / 278.84 2 23
Average= 3.87
(KJ/cycle)

Cycle 70 GMT 4/10/2024 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 27 15.07 521 212 0.21 / 271.33 2 17
2 7 2010.00 38 14.80 2908 1635 1.85 / 272.96 2 10
3 13 1286.48 18 14.88 2087 559 2.41 / 273.52 2 14
4 13 805.64 18 14.95 1463 394 2.80 / 273.92 2 16
5 13 258.64 18 15.08 741 201 3.00 / 274.12 2 19
6 8 -0.12 165 15.11 366 912 3.91 / 275.03 2 26
Average= 3.87
(KJ/cycle)

Cycle 69 GMT 24/ 9/2024 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 15.07 532 224 0.22 / 267.46 2 14
2 3 975.68 -1 15.40 0 0 0.00 / 267.46 2 14
3 7 2008.52 38 14.81 2904 1634 1.86 / 269.09 2 11
4 13 1311.44 18 14.89 2074 556 2.41 / 269.65 2 14
5 13 763.88 18 14.98 1391 375 2.79 / 270.03 2 16
6 13 261.36 18 15.11 720 196 2.99 / 270.22 2 17
7 8 0.08 165 15.12 359 896 3.88 / 271.12 2 25
Average= 3.87
(KJ/cycle)

Cycle 68 GMT 14/ 9/2024 23: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 29 15.05 515 225 0.22 / 263.57 2 13
2 3 965.92 -1 15.38 0 0 0.00 / 263.57 2 13
3 7 2012.40 38 14.81 2921 1644 1.87 / 265.21 2 10
4 13 1280.44 18 14.90 2066 554 2.42 / 265.76 2 15
5 13 712.48 18 14.99 1348 364 2.79 / 266.13 2 16
6 13 261.28 18 15.10 746 203 2.99 / 266.33 2 20
7 8 0.20 165 15.13 363 906 3.90 / 267.24 2 26
Average= 3.87
(KJ/cycle)

Cycle 67 GMT 5/ 9/2024 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 15.09 516 210 0.21 / 259.49 2 16
2 10 1000.36 2 15.02 1752 53 0.26 / 259.54 2 13
3 7 2003.76 39 14.80 2908 1678 1.94 / 261.22 2 11
4 13 1217.76 18 14.90 1966 527 2.47 / 261.75 2 14
5 13 750.32 18 14.97 1374 370 2.84 / 262.12 2 16
6 13 174.16 18 15.12 611 166 3.01 / 262.28 2 20
7 8 0.16 165 15.13 359 896 3.90 / 263.18 2 21
8 14 0.16 30 15.09 360 163 4.06 / 263.34 2 26
Average= 3.87
(KJ/cycle)

Cycle 66 GMT 26/ 8/2024 8: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 28 15.07 529 223 0.22 / 255.46 2 14
2 7 2003.08 38 14.82 2899 1633 1.86 / 257.09 2 11
3 13 1307.84 18 14.92 2098 563 2.42 / 257.66 2 14
4 13 795.52 18 14.99 1445 390 2.81 / 258.05 2 16
5 13 137.72 18 15.16 574 157 2.97 / 258.20 2 20
6 8 0.16 165 15.15 364 910 3.88 / 259.11 2 22
7 14 0.16 30 15.12 362 164 4.04 / 259.28 3 21
Average= 3.87
(KJ/cycle)

Cycle 65 GMT 16/ 8/2024 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 15.08 514 217 0.22 / 251.55 2 15
2 7 2009.08 38 14.79 2904 1632 1.85 / 253.18 2 9
3 13 1354.64 18 14.88 2161 579 2.43 / 253.76 2 13
4 13 781.56 18 14.97 1430 385 2.81 / 254.15 2 16
5 13 214.76 18 15.12 679 185 3.00 / 254.33 2 21
6 8 -0.08 165 15.12 363 906 3.90 / 255.24 2 23
Average= 3.87
(KJ/cycle)

Cycle 64 GMT 6/ 8/2024 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 28 15.08 516 218 0.22 / 247.70 2 15
2 7 2007.40 38 14.80 2912 1638 1.86 / 249.34 2 10
3 13 1294.92 18 14.90 2076 557 2.41 / 249.89 2 15
4 13 705.24 18 15.01 1335 361 2.77 / 250.25 2 17
5 13 215.16 18 15.12 670 182 2.96 / 250.44 2 21
6 8 0.32 165 15.13 359 896 3.85 / 251.33 2 22
Average= 3.87
(KJ/cycle)

Cycle 63 GMT 27/ 7/2024 21:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 28 15.07 536 226 0.23 / 243.76 2 14
2 3 1019.76 1 15.06 1787 27 0.25 / 243.78 2 13
3 7 2005.68 38 14.81 2908 1637 1.89 / 245.42 2 10
4 13 1413.44 18 14.88 2233 598 2.49 / 246.02 2 14
5 13 769.12 18 15.01 1412 381 2.87 / 246.40 2 16
6 13 218.00 18 15.12 676 184 3.05 / 246.58 2 18
7 8 0.00 165 15.13 359 896 3.95 / 247.48 2 22
Average= 3.87
(KJ/cycle)

Cycle 62 GMT 18/ 7/2024 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 15.07 522 220 0.22 / 239.80 2 14
2 3 971.12 -1 15.41 0 0 0.00 / 239.80 2 14
3 7 2011.36 38 14.80 2919 1642 1.86 / 241.44 2 12
4 13 1390.76 18 14.88 2213 593 2.45 / 242.04 2 14
5 13 800.04 18 14.99 1455 393 2.85 / 242.43 2 16
6 13 262.60 18 15.11 723 197 3.04 / 242.63 2 19
7 8 0.32 165 15.13 363 906 3.95 / 243.53 2 28
Average= 3.87
(KJ/cycle)

Cycle 61 GMT 8/ 7/2024 7:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 27 15.07 524 213 0.21 / 235.69 2 14
2 10 1015.60 2 15.03 1785 54 0.27 / 235.74 2 13
3 7 2003.60 38 14.80 2923 1644 1.91 / 237.38 2 10
4 13 1253.88 18 14.91 2039 547 2.46 / 237.93 2 14
5 13 793.00 18 14.98 1446 390 2.85 / 238.32 2 16
6 13 230.20 18 15.11 697 190 3.04 / 238.51 2 18
7 8 -0.24 165 15.13 364 909 3.95 / 239.42 2 24
8 14 -0.24 30 15.11 360 163 4.11 / 239.58 2 24
Average= 3.86
(KJ/cycle)

Cycle 60 GMT 28/ 6/2024 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 28 15.08 527 223 0.22 / 231.77 2 15
2 3 959.84 -1 15.39 0 0 0.00 / 231.77 2 15
3 7 2005.92 38 14.81 2911 1638 1.86 / 233.41 2 10
4 13 1299.08 18 14.91 2077 557 2.42 / 233.97 2 14
5 13 835.40 18 14.99 1499 404 2.82 / 234.37 2 17
6 13 249.76 18 15.13 722 197 3.02 / 234.57 2 20
7 8 0.44 165 15.14 362 904 3.92 / 235.47 2 25
Average= 3.86
(KJ/cycle)

Cycle 59 GMT 18/ 6/2024 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 26 15.11 508 200 0.20 / 227.67 2 14
2 10 1029.44 2 15.03 1794 54 0.25 / 227.73 2 12
3 3 1032.64 1 15.07 1814 27 0.28 / 227.76 2 13
4 7 2009.72 38 14.81 2917 1642 1.92 / 229.40 2 10
5 13 1324.00 18 14.90 2125 570 2.49 / 229.97 2 14
6 13 643.24 18 15.04 1256 340 2.83 / 230.31 2 17
7 13 212.60 18 15.13 669 182 3.01 / 230.49 2 18
8 8 0.16 165 15.14 359 897 3.91 / 231.39 2 24
9 14 0.16 30 15.12 358 162 4.07 / 231.55 2 21
Average= 3.86
(KJ/cycle)

Cycle 58 GMT 8/ 6/2024 21:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 15.08 515 225 0.23 / 223.81 2 17
2 3 898.68 -2 15.41 0 0 0.00 / 223.81 2 17
3 3 973.92 -1 15.44 0 0 0.00 / 223.81 2 17
4 7 2003.00 38 14.81 2906 1635 1.86 / 225.45 2 11
5 13 1298.72 18 14.93 2097 564 2.42 / 226.01 2 13
6 13 771.64 18 15.01 1427 386 2.81 / 226.40 2 16
7 13 224.36 18 15.15 684 187 3.00 / 226.58 2 18
8 8 0.04 165 15.15 357 892 3.89 / 227.47 2 29
Average= 3.86
(KJ/cycle)

Cycle 57 GMT 30/ 5/2024 1:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 29 15.14 501 220 0.22 / 220.02 2 11
2 7 2003.64 38 14.81 2901 1633 1.85 / 221.65 2 10
3 13 1236.92 18 14.93 2007 539 2.39 / 222.19 2 15
4 13 677.64 18 15.03 1289 349 2.74 / 222.54 2 18
5 13 159.76 18 15.15 592 161 2.90 / 222.70 2 20
6 8 -0.24 165 15.15 355 887 3.79 / 223.59 2 20
Average= 3.85
(KJ/cycle)

Cycle 56 GMT 20/ 5/2024 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 30 15.11 511 232 0.23 / 216.18 2 10
2 3 972.16 -1 15.42 0 0 0.00 / 216.18 2 10
3 7 2009.44 38 14.83 2913 1642 1.87 / 217.83 2 10
4 13 1295.80 18 14.94 2076 558 2.43 / 218.38 2 14
5 13 758.32 18 15.04 1391 377 2.81 / 218.76 2 17
6 13 174.16 18 15.18 602 164 2.97 / 218.93 2 18
7 8 0.20 165 15.18 348 872 3.84 / 219.80 2 19
Average= 3.86
(KJ/cycle)

Cycle 55 GMT 10/ 5/2024 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 30 15.11 497 225 0.23 / 212.25 2 11
2 7 2007.88 39 14.83 2908 1682 1.91 / 213.93 2 11
3 13 1294.56 18 14.93 2078 558 2.47 / 214.49 2 14
4 13 761.60 18 15.03 1394 377 2.84 / 214.87 2 17
5 13 252.00 18 15.14 718 196 3.04 / 215.06 2 19
6 8 0.12 165 15.16 355 888 3.93 / 215.95 2 19
Average= 3.86
(KJ/cycle)

Cycle 54 GMT 30/ 4/2024 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 15.10 525 238 0.24 / 208.40 2 10
2 7 2008.36 38 14.83 2909 1639 1.88 / 210.03 2 10
3 13 1310.28 18 14.92 2096 563 2.44 / 210.60 2 13
4 13 737.68 18 15.03 1364 369 2.81 / 210.97 2 16
5 13 196.16 18 15.16 638 174 2.98 / 211.14 2 17
6 8 0.24 165 15.16 354 885 3.87 / 212.03 2 26
Average= 3.86
(KJ/cycle)

Cycle 53 GMT 20/ 4/2024 20:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 134.84 30 15.09 553 250 0.25 / 204.54 2 10
2 7 2010.04 38 14.82 2915 1642 1.89 / 206.19 2 10
3 13 1217.96 18 14.95 1996 537 2.43 / 206.72 2 15
4 13 827.36 18 15.01 1470 397 2.83 / 207.12 2 16
5 13 129.84 18 15.17 558 152 2.98 / 207.27 2 18
6 8 0.24 165 15.16 354 885 3.86 / 208.16 2 23
Average= 3.85
(KJ/cycle)

Cycle 52 GMT 11/ 4/2024 1: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 15.14 496 225 0.23 / 200.22 2 10
2 7 2010.80 39 14.83 2908 1682 1.91 / 201.90 2 9
3 13 1594.68 18 14.88 2446 655 2.56 / 202.55 2 12
4 13 847.32 18 15.01 1499 405 2.97 / 202.96 2 16
5 13 472.12 18 15.09 1021 277 3.24 / 203.24 2 18
6 8 0.12 165 15.17 358 896 4.14 / 204.13 2 26
7 14 0.12 30 15.15 354 161 4.30 / 204.29 3 22
Average= 3.85
(KJ/cycle)

Cycle 51 GMT 1/ 4/2024 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 30 15.14 490 223 0.22 / 196.30 2 10
2 7 2009.76 38 14.85 2908 1641 1.86 / 197.94 2 10
3 13 1482.80 18 14.91 2294 616 2.48 / 198.56 2 12
4 13 798.12 18 15.03 1427 386 2.87 / 198.94 2 16
5 13 255.00 18 15.15 707 193 3.06 / 199.14 2 17
6 8 -0.04 165 15.18 341 854 3.91 / 199.99 2 20
Average= 3.85
(KJ/cycle)

Cycle 50 GMT 22/ 3/2024 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 30 15.13 489 222 0.22 / 192.37 2 10
2 7 2004.52 39 14.85 2912 1686 1.91 / 194.06 2 10
3 13 1368.12 18 14.94 2166 582 2.49 / 194.64 2 13
4 13 920.36 18 15.01 1601 433 2.92 / 195.07 2 16
5 13 157.28 18 15.21 574 157 3.08 / 195.23 2 16
6 8 -0.04 165 15.20 339 850 3.93 / 196.08 2 22
Average= 3.84
(KJ/cycle)

Cycle 49 GMT 12/ 3/2024 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 15.13 486 221 0.22 / 188.50 2 11
2 7 2008.84 38 14.85 2904 1639 1.86 / 190.14 2 10
3 13 1357.92 18 14.94 2145 577 2.44 / 190.72 2 13
4 13 850.72 18 15.02 1502 406 2.84 / 191.12 2 16
5 13 201.00 18 15.19 637 174 3.02 / 191.30 2 18
6 8 0.20 165 15.19 340 852 3.87 / 192.15 2 22
Average= 3.84
(KJ/cycle)

Cycle 48 GMT 2/ 3/2024 20:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 30 15.13 503 228 0.23 / 184.67 2 10
2 7 2004.00 38 14.84 2897 1634 1.86 / 186.30 2 10
3 13 1304.48 18 14.95 2087 562 2.42 / 186.86 2 13
4 13 827.12 18 15.03 1487 402 2.83 / 187.26 2 16
5 13 191.80 18 15.18 624 171 3.00 / 187.44 2 17
6 8 0.44 165 15.19 337 845 3.84 / 188.28 2 24
Average= 3.84
(KJ/cycle)

Cycle 47 GMT 22/ 2/2024 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 30 15.13 491 223 0.22 / 180.79 2 10
2 7 2005.28 38 14.85 2908 1641 1.86 / 182.43 2 10
3 13 1385.92 18 14.92 2177 585 2.45 / 183.02 2 13
4 13 765.40 18 15.03 1389 376 2.82 / 183.39 2 15
5 13 199.28 18 15.17 640 175 3.00 / 183.57 2 17
6 8 -0.04 165 15.19 347 870 3.87 / 184.44 2 22
Average= 3.84
(KJ/cycle)

Cycle 46 GMT 12/ 2/2024 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 15.12 494 224 0.22 / 177.01 2 10
2 7 2004.84 38 14.83 2895 1631 1.86 / 178.64 2 10
3 13 1295.44 18 14.93 2072 557 2.41 / 179.20 2 13
4 13 730.96 18 15.03 1350 365 2.78 / 179.56 2 16
5 13 111.28 18 15.19 521 142 2.92 / 179.71 2 18
6 8 0.08 165 15.17 345 864 3.78 / 180.57 2 26
Average= 3.84
(KJ/cycle)

Cycle 45 GMT 2/ 2/2024 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 30 15.15 508 231 0.23 / 172.97 2 11
2 7 2004.32 38 14.84 2915 1644 1.87 / 174.61 2 10
3 13 1397.52 18 14.94 2214 595 2.47 / 175.21 2 12
4 13 811.24 18 15.03 1474 399 2.87 / 175.61 2 15
5 13 180.00 18 15.19 609 167 3.04 / 175.77 2 18
6 8 -0.04 165 15.18 343 859 3.89 / 176.63 2 23
7 14 -0.04 30 15.16 339 154 4.05 / 176.79 3 24
Average= 3.84
(KJ/cycle)

Cycle 44 GMT 23/ 1/2024 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 15.13 519 236 0.24 / 169.08 2 12
2 7 2003.56 39 14.85 2906 1683 1.92 / 170.77 2 10
3 13 1298.08 18 14.96 2094 564 2.48 / 171.33 2 13
4 13 763.72 18 15.04 1401 379 2.86 / 171.71 2 16
5 13 166.20 18 15.20 594 163 3.02 / 171.87 2 19
6 8 0.20 165 15.19 346 867 3.89 / 172.74 2 22
Average= 3.84
(KJ/cycle)

Cycle 43 GMT 13/ 1/2024 19:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 15.14 507 230 0.23 / 165.18 2 12
2 7 2009.96 38 14.85 2923 1649 1.88 / 166.83 2 10
3 13 1331.16 18 14.96 2138 576 2.46 / 167.41 2 13
4 13 789.76 18 15.05 1436 389 2.84 / 167.79 2 16
5 13 195.52 18 15.18 632 173 3.02 / 167.97 2 16
6 8 0.04 165 15.19 351 880 3.90 / 168.85 2 27
Average= 3.84
(KJ/cycle)

Cycle 42 GMT 4/ 1/2024 0:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 15.15 510 232 0.23 / 161.29 2 11
2 7 2004.44 38 14.87 2909 1644 1.88 / 162.93 2 10
3 13 1349.24 18 14.96 2151 579 2.45 / 163.51 2 13
4 13 778.76 18 15.05 1409 382 2.84 / 163.90 2 16
5 13 191.92 18 15.19 630 172 3.01 / 164.07 2 17
6 8 0.12 165 15.19 352 882 3.89 / 164.95 2 22
Average= 3.84
(KJ/cycle)

Cycle 41 GMT 25/12/2023 5:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 30 15.15 496 225 0.23 / 157.34 2 11
2 3 1017.28 1 15.15 1787 27 0.25 / 157.36 2 12
3 7 2009.16 38 14.87 2920 1650 1.90 / 159.01 2 10
4 13 1339.60 18 14.97 2144 578 2.48 / 159.59 2 13
5 13 759.24 18 15.08 1399 380 2.86 / 159.97 2 16
6 13 214.12 18 15.20 667 182 3.04 / 160.15 2 18
7 8 0.36 165 15.20 361 905 3.95 / 161.06 2 25
Average= 3.83
(KJ/cycle)

Cycle 40 GMT 15/12/2023 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 30 15.16 507 231 0.23 / 153.31 2 11
2 7 2006.68 38 14.86 2904 1640 1.87 / 154.95 2 10
3 13 1338.04 18 14.95 2142 576 2.45 / 155.53 2 14
4 13 795.32 18 15.06 1427 387 2.83 / 155.92 2 16
5 13 157.80 18 15.20 581 159 2.99 / 156.08 2 16
6 8 -0.12 165 15.21 351 881 3.87 / 156.96 2 23
7 14 -0.12 30 15.18 338 154 4.03 / 157.11 2 25
Average= 3.83
(KJ/cycle)

Cycle 39 GMT 5/12/2023 14:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 30 15.18 495 225 0.23 / 149.42 2 11
2 3 975.88 -1 15.48 0 0 0.00 / 149.42 2 11
3 7 2010.32 38 14.87 2905 1641 1.87 / 151.06 2 9
4 13 1338.92 18 14.99 2139 577 2.44 / 151.64 2 13
5 13 796.40 18 15.06 1444 391 2.84 / 152.03 2 16
6 13 158.24 18 15.22 586 161 3.00 / 152.19 2 17
7 8 -0.04 165 15.22 356 894 3.89 / 153.08 2 29
Average= 3.83
(KJ/cycle)

Cycle 38 GMT 25/11/2023 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 15.16 501 228 0.23 / 145.50 2 11
2 7 2003.96 38 14.88 2912 1647 1.87 / 147.15 2 11
3 13 1385.72 18 14.97 2221 598 2.47 / 147.75 2 13
4 13 786.28 18 15.07 1435 389 2.86 / 148.14 2 15
5 13 186.44 18 15.23 617 169 3.03 / 148.31 2 18
6 8 0.28 165 15.22 353 886 3.92 / 149.19 2 29
Average= 3.83
(KJ/cycle)

Cycle 37 GMT 16/11/2023 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 30 15.15 506 230 0.23 / 141.59 2 12
2 7 2010.20 38 14.86 2911 1644 1.87 / 143.23 2 11
3 13 1317.08 18 14.96 2124 572 2.45 / 143.80 2 13
4 13 822.76 18 15.05 1487 403 2.85 / 144.21 2 16
5 13 217.28 18 15.19 672 184 3.03 / 144.39 2 16
6 8 0.08 165 15.21 353 886 3.92 / 145.28 2 20
Average= 3.82
(KJ/cycle)

Cycle 36 GMT 6/11/2023 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 15.15 506 230 0.23 / 137.71 2 11
2 7 2003.24 38 14.88 2906 1643 1.87 / 139.35 2 11
3 13 1350.68 18 14.97 2145 578 2.45 / 139.93 2 13
4 13 761.92 18 15.08 1393 378 2.83 / 140.31 2 15
5 13 171.68 18 15.21 604 165 2.99 / 140.47 2 17
6 8 0.32 165 15.21 352 883 3.88 / 141.36 2 20
Average= 3.82
(KJ/cycle)

Cycle 35 GMT 27/10/2023 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 30 15.16 485 221 0.22 / 133.66 2 12
2 7 2003.44 38 14.88 2922 1652 1.87 / 135.31 2 10
3 13 1312.24 18 14.98 2110 569 2.44 / 135.88 2 13
4 13 783.12 18 15.09 1426 387 2.83 / 136.27 2 16
5 13 149.88 18 15.23 572 157 2.99 / 136.42 2 17
6 8 0.00 165 15.22 357 897 3.88 / 137.32 2 24
7 14 0.00 30 15.20 351 160 4.04 / 137.48 2 21
Average= 3.82
(KJ/cycle)

Cycle 34 GMT 17/10/2023 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 30 15.18 491 224 0.22 / 129.80 2 11
2 7 2010.88 38 14.89 2898 1640 1.86 / 131.44 2 9
3 13 1308.84 18 14.99 2090 564 2.43 / 132.01 2 13
4 13 780.44 18 15.09 1405 382 2.81 / 132.39 2 16
5 13 189.24 18 15.23 625 171 2.98 / 132.56 2 17
6 8 -0.04 165 15.22 349 876 3.86 / 133.44 2 29
Average= 3.81
(KJ/cycle)

Cycle 33 GMT 7/10/2023 19:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 15.17 498 227 0.23 / 125.92 2 10
2 7 2003.20 39 14.90 2898 1684 1.91 / 127.60 2 10
3 13 1340.84 18 15.00 2132 576 2.49 / 128.18 2 13
4 13 797.92 18 15.08 1420 385 2.87 / 128.56 2 16
5 13 115.84 18 15.25 521 143 3.01 / 128.71 2 17
6 8 0.00 165 15.23 348 875 3.89 / 129.58 2 21
Average= 3.81
(KJ/cycle)

Cycle 32 GMT 28/ 9/2023 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 30 15.17 505 230 0.23 / 121.96 2 10
2 7 2011.32 38 14.88 2916 1649 1.88 / 123.61 2 10
3 13 1346.00 18 14.99 2151 580 2.46 / 124.19 2 12
4 13 850.40 18 15.07 1519 412 2.87 / 124.60 2 15
5 13 244.44 18 15.21 702 192 3.06 / 124.79 2 16
6 8 0.44 165 15.21 359 901 3.96 / 125.69 2 28
Average= 3.81
(KJ/cycle)

Cycle 31 GMT 18/ 9/2023 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 30 15.18 504 230 0.23 / 118.05 2 10
2 7 2012.24 38 14.90 2908 1647 1.88 / 119.69 2 9
3 13 1369.24 18 14.99 2155 581 2.46 / 120.27 2 13
4 13 823.00 18 15.08 1467 398 2.86 / 120.67 2 16
5 13 197.40 18 15.23 633 174 3.03 / 120.84 2 18
6 8 -0.28 165 15.23 351 882 3.91 / 121.73 2 23
Average= 3.80
(KJ/cycle)

Cycle 30 GMT 8/ 9/2023 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 30 15.20 511 233 0.23 / 114.12 2 11
2 7 2005.40 38 14.90 2905 1645 1.88 / 115.77 2 9
3 13 1349.92 18 14.99 2150 580 2.46 / 116.35 2 12
4 13 849.08 18 15.08 1510 410 2.87 / 116.76 2 16
5 13 164.48 18 15.24 593 163 3.03 / 116.92 2 15
6 8 0.60 165 15.23 357 897 3.93 / 117.82 2 20
Average= 3.80
(KJ/cycle)

Cycle 29 GMT 29/ 8/2023 14:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 30 15.18 513 234 0.23 / 110.20 2 12
2 7 2008.28 38 14.91 2906 1646 1.88 / 111.84 2 9
3 13 1340.36 18 15.00 2148 580 2.46 / 112.42 2 13
4 13 798.92 18 15.09 1450 394 2.85 / 112.82 2 16
5 13 200.56 18 15.24 642 176 3.03 / 112.99 2 17
6 8 -0.12 165 15.24 356 895 3.93 / 113.89 2 20
Average= 3.80
(KJ/cycle)

Cycle 28 GMT 19/ 8/2023 19:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 30 15.21 510 233 0.23 / 106.30 2 11
2 7 2010.76 38 14.91 2911 1649 1.88 / 107.95 2 10
3 13 1347.88 18 15.00 2161 583 2.47 / 108.54 2 13
4 13 772.76 18 15.10 1412 384 2.85 / 108.92 2 16
5 13 150.48 18 15.24 564 155 3.00 / 109.08 2 16
6 8 -0.12 165 15.23 353 887 3.89 / 109.96 2 23
Average= 3.79
(KJ/cycle)

Cycle 27 GMT 9/ 8/2023 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 30 15.19 512 233 0.23 / 102.40 2 11
2 7 2010.72 38 14.90 2911 1648 1.88 / 104.05 2 10
3 13 1384.44 18 14.99 2201 594 2.48 / 104.64 2 13
4 13 758.76 18 15.10 1396 379 2.85 / 105.02 2 16
5 13 162.56 18 15.25 591 162 3.02 / 105.18 2 16
6 8 0.36 165 15.24 354 890 3.91 / 106.07 2 21
Average= 3.79
(KJ/cycle)

Cycle 26 GMT 31/ 7/2023 4:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 15.20 502 229 0.23 / 98.51 2 12
2 7 2005.52 38 14.90 2903 1644 1.87 / 100.15 2 10
3 13 1303.16 18 15.01 2097 567 2.44 / 100.72 2 13
4 13 770.28 18 15.10 1404 382 2.82 / 101.10 2 16
5 13 177.64 18 15.25 609 167 2.99 / 101.27 2 16
6 8 -0.08 165 15.24 357 898 3.89 / 102.16 2 21
Average= 3.78
(KJ/cycle)

Cycle 25 GMT 21/ 7/2023 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 15.19 500 228 0.23 / 94.58 2 12
2 7 2009.80 38 14.92 2918 1654 1.88 / 96.24 2 9
3 13 1343.48 18 15.01 2157 583 2.47 / 96.82 2 13
4 13 798.72 18 15.10 1428 388 2.85 / 97.21 2 16
5 13 201.80 18 15.24 643 176 3.03 / 97.38 2 17
6 8 0.20 165 15.24 356 895 3.92 / 98.28 2 26
Average= 3.78
(KJ/cycle)

Cycle 24 GMT 11/ 7/2023 14:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 29 15.20 516 227 0.23 / 90.65 2 11
2 10 1008.68 2 15.18 1758 53 0.28 / 90.70 2 11
3 3 974.08 -1 15.51 0 0 0.05 / 90.70 2 11
4 7 2012.28 38 14.92 2908 1649 1.93 / 92.35 2 9
5 13 1305.88 18 15.03 2111 571 2.50 / 92.92 2 13
6 13 817.04 18 15.10 1450 394 2.89 / 93.32 2 16
7 13 122.76 18 15.27 539 148 3.04 / 93.46 2 18
8 8 0.56 165 15.25 354 891 3.93 / 94.35 2 20
Average= 3.77
(KJ/cycle)

Cycle 23 GMT 1/ 7/2023 18:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 15.19 498 219 0.22 / 86.74 2 13
2 7 2007.56 38 14.93 2922 1658 1.88 / 88.40 2 10
3 13 1301.56 18 15.03 2102 569 2.45 / 88.97 2 13
4 13 773.64 18 15.12 1422 387 2.83 / 89.36 2 16
5 13 178.40 18 15.26 611 168 3.00 / 89.52 2 17
6 8 -0.52 165 15.26 356 896 3.90 / 90.42 2 25
Average= 3.77
(KJ/cycle)

Cycle 22 GMT 21/ 6/2023 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 15.21 513 226 0.23 / 82.86 2 13
2 7 2011.68 38 14.92 2906 1648 1.87 / 84.50 2 10
3 13 1327.52 18 15.03 2131 577 2.45 / 85.08 2 13
4 13 786.96 18 15.11 1440 392 2.84 / 85.47 2 16
5 13 156.76 18 15.26 592 163 3.00 / 85.64 2 16
6 8 0.32 165 15.25 353 888 3.89 / 86.52 2 24
Average= 3.76
(KJ/cycle)

Cycle 21 GMT 12/ 6/2023 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 15.19 503 222 0.22 / 78.94 2 10
2 7 2006.28 38 14.93 2907 1649 1.87 / 80.59 2 10
3 13 1334.12 18 15.04 2147 581 2.45 / 81.17 2 13
4 13 794.12 18 15.12 1458 397 2.85 / 81.57 2 16
5 13 157.64 18 15.28 590 162 3.01 / 81.73 2 19
6 8 0.28 165 15.27 356 897 3.91 / 82.63 2 20
Average= 3.76
(KJ/cycle)

Cycle 20 GMT 2/ 6/2023 9:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 15.23 498 220 0.22 / 74.90 2 13
2 7 2007.32 38 14.93 2905 1648 1.87 / 76.55 2 10
3 13 1313.84 18 15.02 2108 570 2.44 / 77.12 2 13
4 13 784.32 18 15.11 1432 389 2.83 / 77.51 2 16
5 13 154.12 18 15.25 581 159 2.99 / 77.67 2 18
6 8 0.24 165 15.25 353 888 3.88 / 78.56 2 25
7 14 0.24 30 15.23 357 163 4.04 / 78.72 3 26
Average= 3.75
(KJ/cycle)

Cycle 19 GMT 23/ 5/2023 13:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 15.22 498 220 0.22 / 71.02 2 14
2 3 1018.32 1 15.21 1799 27 0.25 / 71.04 2 12
3 7 2008.88 38 14.93 2920 1657 1.90 / 72.70 2 10
4 13 1298.88 18 15.06 2096 568 2.47 / 73.27 2 14
5 13 762.48 18 15.13 1401 382 2.85 / 73.65 2 16
6 13 95.24 18 15.30 499 137 2.99 / 73.79 2 16
7 8 0.04 165 15.27 356 897 3.89 / 74.68 2 25
Average= 3.73
(KJ/cycle)

Cycle 18 GMT 13/ 5/2023 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 15.22 502 222 0.22 / 67.16 2 13
2 7 2011.04 38 14.94 2904 1649 1.87 / 68.81 2 10
3 13 1253.96 18 15.07 2017 547 2.42 / 69.36 2 14
4 13 775.72 18 15.13 1410 384 2.80 / 69.74 2 17
5 13 154.00 18 15.28 576 158 2.96 / 69.90 2 19
6 8 0.12 165 15.27 355 894 3.85 / 70.80 2 27
Average= 3.73
(KJ/cycle)

Cycle 17 GMT 3/ 5/2023 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.23 494 211 0.21 / 63.23 2 12
2 7 2006.36 39 14.95 2909 1696 1.91 / 64.93 2 10
3 13 1293.04 18 15.05 2086 565 2.47 / 65.49 2 13
4 13 750.20 18 15.16 1385 378 2.85 / 65.87 2 16
5 13 154.80 18 15.29 589 162 3.01 / 66.03 2 19
6 8 0.20 165 15.27 361 910 3.92 / 66.94 2 23
Average= 3.72
(KJ/cycle)

Cycle 16 GMT 24/ 4/2023 3:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 15.23 500 213 0.21 / 59.27 2 11
2 7 2005.92 38 14.96 2916 1658 1.87 / 60.93 2 9
3 13 1257.16 18 15.07 2028 550 2.42 / 61.48 2 13
4 13 694.88 18 15.16 1299 354 2.78 / 61.83 2 15
5 13 123.60 18 15.30 536 148 2.92 / 61.98 2 18
6 8 -0.20 165 15.27 350 882 3.80 / 62.86 2 21
7 14 -0.20 30 15.26 342 157 3.96 / 63.02 2 27
Average= 3.71
(KJ/cycle)

Cycle 15 GMT 14/ 4/2023 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 28 15.22 510 217 0.22 / 55.23 2 12
2 7 2004.52 38 14.95 2912 1654 1.87 / 56.88 2 9
3 13 1251.64 18 15.07 2024 549 2.42 / 57.43 2 13
4 13 719.48 18 15.15 1353 369 2.79 / 57.80 2 16
5 13 211.96 18 15.27 670 184 2.97 / 57.98 2 17
6 8 0.20 165 15.28 363 915 3.89 / 58.90 2 20
7 14 0.20 30 15.24 354 162 4.05 / 59.06 2 25
Average= 3.69
(KJ/cycle)

Cycle 14 GMT 4/ 4/2023 12:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 28 15.22 517 220 0.22 / 51.36 2 12
2 7 2006.20 38 14.95 2910 1653 1.87 / 53.01 2 9
3 13 1240.72 18 15.07 2018 547 2.42 / 53.56 2 13
4 13 750.04 18 15.15 1387 378 2.80 / 53.94 2 16
5 13 150.64 18 15.28 583 160 2.96 / 54.10 2 18
6 8 0.16 165 15.28 360 908 3.87 / 55.01 2 25
Average= 3.67
(KJ/cycle)

Cycle 13 GMT 25/ 3/2023 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 28 15.23 509 217 0.22 / 47.49 2 12
2 7 2005.48 38 14.95 2908 1652 1.87 / 49.14 2 9
3 13 1295.20 18 15.06 2083 565 2.43 / 49.71 2 13
4 13 708.32 18 15.16 1329 363 2.80 / 50.07 2 16
5 13 168.40 18 15.28 612 168 2.96 / 50.24 2 18
6 8 0.00 165 15.28 358 903 3.87 / 51.14 2 21
Average= 3.65
(KJ/cycle)

Cycle 12 GMT 15/ 3/2023 21:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 28 15.24 502 214 0.21 / 43.59 2 12
2 3 1022.08 1 15.22 1799 27 0.24 / 43.62 2 11
3 7 2006.00 39 14.95 2912 1698 1.94 / 45.32 2 9
4 13 1246.04 18 15.07 2015 547 2.49 / 45.87 2 13
5 13 722.96 18 15.15 1335 364 2.85 / 46.23 2 16
6 13 132.96 18 15.29 552 152 3.00 / 46.38 2 18
7 8 -0.04 165 15.28 354 893 3.89 / 47.27 2 24
Average= 3.64
(KJ/cycle)

Cycle 11 GMT 6/ 3/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 27 15.22 519 213 0.21 / 39.80 2 13
2 7 2007.32 38 14.97 2913 1657 1.87 / 41.46 2 9
3 13 1254.56 18 15.08 2017 547 2.42 / 42.01 2 13
4 13 714.76 18 15.17 1333 364 2.78 / 42.37 2 16
5 13 121.92 18 15.31 521 144 2.93 / 42.51 2 18
6 8 0.20 165 15.29 343 865 3.79 / 43.38 2 22
Average= 3.61
(KJ/cycle)

Cycle 10 GMT 24/ 2/2023 7: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 27 15.24 486 200 0.20 / 36.01 2 12
2 7 2004.12 38 14.98 2900 1651 1.85 / 37.66 2 9
3 13 1304.80 18 15.08 2066 561 2.41 / 38.22 2 13
4 13 748.40 18 15.16 1348 368 2.78 / 38.59 2 16
5 13 152.64 18 15.29 551 152 2.93 / 38.74 2 17
6 8 -0.04 165 15.30 336 848 3.78 / 39.59 2 21
Average= 3.60
(KJ/cycle)

Cycle 9 GMT 14/ 2/2023 11:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 15.24 478 197 0.20 / 32.28 2 14
2 3 1031.08 1 15.22 1796 27 0.22 / 32.30 2 13
3 7 2004.56 38 14.97 2901 1650 1.87 / 33.95 2 8
4 13 1317.28 18 15.07 2085 566 2.44 / 34.52 2 12
5 13 642.72 18 15.19 1213 332 2.77 / 34.85 2 15
6 13 78.04 18 15.32 450 124 2.90 / 34.97 2 17
7 8 0.08 165 15.29 331 835 3.73 / 35.81 2 22
Average= 3.58
(KJ/cycle)

Cycle 8 GMT 4/ 2/2023 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.22 493 210 0.21 / 28.56 2 14
2 3 926.68 -2 15.52 0 0 0.00 / 28.56 2 14
3 7 2003.44 38 14.97 2899 1649 1.86 / 30.20 2 10
4 13 1263.48 18 15.08 2015 547 2.41 / 30.75 2 14
5 13 665.76 18 15.20 1241 340 2.75 / 31.09 2 17
6 13 124.68 18 15.32 513 141 2.89 / 31.23 2 18
7 8 -0.04 165 15.30 335 846 3.73 / 32.08 2 23
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 25/ 1/2023 20:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 26 15.25 487 193 0.19 / 25.07 2 13
2 7 1773.08 38 14.99 2638 1503 1.70 / 26.57 2 10
3 13 1100.36 18 15.10 1802 490 2.19 / 27.06 2 14
4 13 619.96 18 15.19 1178 322 2.51 / 27.39 2 15
5 13 71.20 18 15.33 442 122 2.63 / 27.51 2 17
6 8 0.20 165 15.29 332 838 3.47 / 28.35 2 22
Average= 3.54
(KJ/cycle)

Cycle 6 GMT 24/ 1/2023 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 26 15.23 499 198 0.20 / 20.86 2 13
2 3 1019.28 1 15.29 1786 27 0.22 / 20.89 2 10
3 7 1792.80 74 14.88 2648 2916 3.14 / 23.80 2 10
4 13 363.68 18 15.24 838 230 3.37 / 24.03 2 16
5 8 0.20 165 15.30 335 846 4.22 / 24.88 2 23
Average= 3.55
(KJ/cycle)

Cycle 5 GMT 23/ 1/2023 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 26 15.24 479 190 0.19 / 16.58 2 12
2 7 1780.48 74 14.89 2626 2893 3.08 / 19.47 2 10
3 13 393.16 18 15.23 870 239 3.32 / 19.71 2 16
4 13 52.12 18 15.31 411 113 3.44 / 19.82 2 17
5 8 0.40 165 15.28 332 837 4.27 / 20.66 2 24
Average= 3.44
(KJ/cycle)

Cycle 4 GMT 22/ 1/2023 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 26 15.25 495 196 0.20 / 12.42 2 12
2 7 1524.32 74 14.98 2321 2573 2.77 / 15.00 2 11
3 13 270.52 18 15.28 703 193 2.96 / 15.19 2 16
4 8 -0.12 165 15.31 327 826 3.79 / 16.02 2 22
5 14 -0.12 75 15.27 326 373 4.16 / 16.39 2 25
Average= 3.28
(KJ/cycle)

Cycle 3 GMT 21/ 1/2023 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 27 15.25 487 201 0.20 / 8.69 2 12
2 3 963.48 -1 15.59 0 0 0.00 / 8.69 2 12
3 7 1521.68 74 14.99 2315 2568 2.77 / 11.26 2 11
4 13 127.84 18 15.33 507 140 2.91 / 11.40 2 16
5 8 0.12 165 15.31 329 831 3.74 / 12.23 2 21
Average= 3.06
(KJ/cycle)

Cycle 2 GMT 20/ 1/2023 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 31 15.31 495 235 0.23 / 4.95 2 13
2 3 856.88 -3 15.60 0 0 0.00 / 4.95 2 13
3 7 1524.84 74 15.00 2313 2567 2.80 / 7.52 2 11
4 13 125.64 18 15.32 505 139 2.94 / 7.66 2 16
5 8 -0.08 165 15.30 328 828 3.77 / 8.49 2 22
Average= 2.83
(KJ/cycle)

Cycle 1 GMT 19/ 1/2023 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 26 15.46 456 183 0.18 / 2.04 2 6
2 7 985.56 74 15.17 1633 1833 2.02 / 3.88 2 14
3 8 0.04 165 15.36 332 841 2.86 / 4.72 2 24
Average= 2.36
(KJ/cycle)

Cycle 0 GMT 19/ 1/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.24 25 15.62 521 203 0.20 / 0.20 2 4
2 7 183.48 74 15.57 527 607 0.81 / 0.81 2 6
3 8 -0.00 240 15.52 282 1050 1.86 / 1.86 2 28
Average= 1.86
(KJ/cycle)