SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 31 | 15.18 | 498 | 234 | 0.23 / 84.88 | 2 | 4 |
2 | 7 | 2003.72 | 38 | 14.90 | 2849 | 1613 | 1.85 / 86.49 | 2 | 6 |
3 | 13 | 1317.80 | 18 | 14.99 | 2030 | 548 | 2.40 / 87.04 | 2 | 8 |
4 | 13 | 881.40 | 18 | 15.06 | 1503 | 407 | 2.80 / 87.45 | 2 | 10 |
5 | 13 | 302.56 | 18 | 15.20 | 754 | 206 | 3.01 / 87.66 | 2 | 11 |
6 | 13 | 55.72 | 18 | 15.26 | 408 | 112 | 3.12 / 87.77 | 2 | 9 |
7 | 8 | -0.04 | 165 | 15.22 | 326 | 819 | 3.94 / 88.59 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 31 | 15.19 | 481 | 226 | 0.23 / 80.90 | 2 | 3 |
2 | 7 | 2004.04 | 38 | 14.91 | 2842 | 1610 | 1.84 / 82.51 | 2 | 5 |
3 | 13 | 1423.76 | 18 | 14.99 | 2168 | 585 | 2.42 / 83.09 | 2 | 8 |
4 | 13 | 827.04 | 18 | 15.08 | 1428 | 388 | 2.81 / 83.48 | 2 | 10 |
5 | 13 | 352.80 | 18 | 15.19 | 833 | 228 | 3.04 / 83.71 | 2 | 11 |
6 | 13 | 49.88 | 18 | 15.27 | 405 | 111 | 3.15 / 83.82 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.23 | 330 | 829 | 3.98 / 84.65 | 2 | 7 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 31 | 15.18 | 473 | 223 | 0.22 / 76.77 | 2 | 3 |
2 | 7 | 2005.16 | 38 | 14.90 | 2849 | 1613 | 1.84 / 78.38 | 2 | 6 |
3 | 13 | 1345.76 | 18 | 15.00 | 2070 | 559 | 2.39 / 78.94 | 2 | 9 |
4 | 13 | 860.96 | 18 | 15.07 | 1478 | 401 | 2.80 / 79.34 | 2 | 10 |
5 | 13 | 364.12 | 18 | 15.19 | 845 | 231 | 3.03 / 79.57 | 2 | 11 |
6 | 13 | 55.08 | 18 | 15.26 | 423 | 116 | 3.14 / 79.69 | 2 | 10 |
7 | 8 | -0.04 | 165 | 15.23 | 330 | 829 | 3.97 / 80.52 | 2 | 5 |
8 | 14 | -0.04 | 30 | 15.20 | 327 | 149 | 4.12 / 80.67 | 2 | 8 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 31 | 15.19 | 478 | 225 | 0.23 / 72.61 | 2 | 4 |
2 | 7 | 2003.08 | 39 | 14.92 | 2827 | 1645 | 1.87 / 74.25 | 2 | 6 |
3 | 13 | 1373.40 | 18 | 14.99 | 2096 | 566 | 2.44 / 74.82 | 2 | 8 |
4 | 13 | 833.32 | 18 | 15.08 | 1435 | 390 | 2.83 / 75.21 | 2 | 10 |
5 | 13 | 354.40 | 18 | 15.19 | 831 | 227 | 3.05 / 75.43 | 2 | 11 |
6 | 13 | 46.20 | 18 | 15.26 | 412 | 113 | 3.17 / 75.55 | 2 | 8 |
7 | 8 | -0.08 | 165 | 15.22 | 338 | 849 | 4.01 / 76.39 | 2 | 8 |
8 | 14 | -0.08 | 30 | 15.19 | 336 | 153 | 4.17 / 76.55 | 2 | 7 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 15.19 | 475 | 224 | 0.22 / 68.68 | 2 | 3 |
2 | 7 | 2005.24 | 38 | 14.93 | 2850 | 1617 | 1.84 / 70.30 | 2 | 6 |
3 | 13 | 1272.12 | 18 | 15.02 | 1991 | 538 | 2.38 / 70.84 | 2 | 8 |
4 | 13 | 769.08 | 18 | 15.10 | 1370 | 372 | 2.75 / 71.21 | 2 | 11 |
5 | 13 | 336.12 | 18 | 15.19 | 810 | 221 | 2.97 / 71.43 | 2 | 11 |
6 | 13 | 43.92 | 18 | 15.26 | 406 | 112 | 3.08 / 71.54 | 2 | 8 |
7 | 8 | -0.12 | 165 | 15.23 | 334 | 839 | 3.92 / 72.38 | 2 | 9 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.00 | 31 | 15.19 | 493 | 232 | 0.23 / 64.69 | 2 | 3 |
2 | 7 | 2006.56 | 38 | 14.92 | 2845 | 1613 | 1.85 / 66.30 | 2 | 6 |
3 | 13 | 1399.08 | 18 | 15.00 | 2141 | 578 | 2.42 / 66.88 | 2 | 8 |
4 | 13 | 856.52 | 18 | 15.09 | 1475 | 401 | 2.82 / 67.28 | 2 | 10 |
5 | 13 | 337.72 | 18 | 15.20 | 816 | 223 | 3.05 / 67.51 | 2 | 11 |
6 | 13 | 43.80 | 18 | 15.27 | 410 | 113 | 3.16 / 67.62 | 2 | 9 |
7 | 8 | 0.24 | 165 | 15.24 | 333 | 837 | 4.00 / 68.46 | 2 | 12 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 31 | 15.19 | 470 | 221 | 0.22 / 60.71 | 2 | 3 |
2 | 7 | 2006.52 | 38 | 14.93 | 2845 | 1614 | 1.84 / 62.32 | 2 | 6 |
3 | 13 | 1349.84 | 18 | 15.02 | 2080 | 562 | 2.40 / 62.88 | 2 | 8 |
4 | 13 | 834.84 | 18 | 15.09 | 1450 | 394 | 2.79 / 63.28 | 2 | 10 |
5 | 13 | 396.36 | 18 | 15.18 | 893 | 244 | 3.04 / 63.52 | 2 | 11 |
6 | 13 | 40.64 | 18 | 15.27 | 401 | 110 | 3.15 / 63.63 | 2 | 9 |
7 | 8 | -0.28 | 165 | 15.23 | 329 | 827 | 3.97 / 64.46 | 2 | 8 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 31 | 15.20 | 456 | 215 | 0.21 / 56.76 | 2 | 3 |
2 | 7 | 2006.84 | 38 | 14.94 | 2833 | 1608 | 1.82 / 58.37 | 2 | 6 |
3 | 13 | 1314.52 | 18 | 15.03 | 2025 | 548 | 2.37 / 58.92 | 2 | 9 |
4 | 13 | 882.40 | 18 | 15.09 | 1499 | 407 | 2.78 / 59.33 | 2 | 10 |
5 | 13 | 345.48 | 18 | 15.20 | 832 | 228 | 3.01 / 59.56 | 2 | 11 |
6 | 13 | 26.00 | 18 | 15.29 | 378 | 104 | 3.11 / 59.66 | 2 | 7 |
7 | 8 | 0.12 | 165 | 15.24 | 329 | 827 | 3.94 / 60.49 | 2 | 7 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 31 | 15.20 | 449 | 212 | 0.21 / 52.86 | 2 | 3 |
2 | 7 | 2003.28 | 38 | 14.94 | 2832 | 1608 | 1.82 / 54.46 | 2 | 6 |
3 | 13 | 1346.64 | 18 | 15.03 | 2061 | 558 | 2.38 / 55.02 | 2 | 8 |
4 | 13 | 819.08 | 18 | 15.12 | 1414 | 385 | 2.76 / 55.41 | 2 | 10 |
5 | 13 | 384.20 | 18 | 15.21 | 858 | 235 | 3.00 / 55.64 | 2 | 11 |
6 | 13 | 36.04 | 18 | 15.29 | 376 | 103 | 3.10 / 55.75 | 2 | 8 |
7 | 8 | 0.08 | 165 | 15.24 | 320 | 805 | 3.90 / 56.55 | 2 | 8 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 31 | 15.20 | 473 | 223 | 0.22 / 48.99 | 2 | 3 |
2 | 7 | 2008.52 | 38 | 14.94 | 2839 | 1612 | 1.83 / 50.60 | 2 | 6 |
3 | 13 | 1313.68 | 18 | 15.02 | 2026 | 548 | 2.38 / 51.15 | 2 | 8 |
4 | 13 | 787.92 | 18 | 15.11 | 1376 | 374 | 2.76 / 51.53 | 2 | 10 |
5 | 13 | 316.00 | 18 | 15.20 | 770 | 211 | 2.97 / 51.74 | 2 | 11 |
6 | 13 | 34.68 | 18 | 15.28 | 380 | 105 | 3.07 / 51.84 | 2 | 7 |
7 | 8 | 0.04 | 165 | 15.24 | 320 | 805 | 3.88 / 52.65 | 2 | 10 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 31 | 15.20 | 454 | 214 | 0.21 / 45.04 | 2 | 3 |
2 | 7 | 2008.96 | 38 | 14.95 | 2839 | 1613 | 1.83 / 46.66 | 2 | 6 |
3 | 13 | 1353.32 | 18 | 15.04 | 2069 | 560 | 2.39 / 47.22 | 2 | 8 |
4 | 13 | 864.64 | 18 | 15.09 | 1476 | 401 | 2.79 / 47.62 | 2 | 10 |
5 | 13 | 367.08 | 18 | 15.21 | 844 | 231 | 3.02 / 47.85 | 2 | 11 |
6 | 13 | 30.60 | 18 | 15.29 | 376 | 103 | 3.12 / 47.95 | 2 | 7 |
7 | 8 | 0.04 | 165 | 15.24 | 325 | 817 | 3.94 / 48.77 | 2 | 8 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.56 | 31 | 15.20 | 491 | 231 | 0.23 / 41.12 | 2 | 3 |
2 | 7 | 2004.48 | 38 | 14.95 | 2830 | 1608 | 1.84 / 42.72 | 2 | 6 |
3 | 13 | 1346.64 | 18 | 15.03 | 2063 | 558 | 2.40 / 43.28 | 2 | 8 |
4 | 13 | 826.32 | 18 | 15.11 | 1421 | 386 | 2.78 / 43.67 | 2 | 10 |
5 | 13 | 378.80 | 18 | 15.20 | 850 | 233 | 3.02 / 43.90 | 2 | 11 |
6 | 13 | 64.24 | 18 | 15.29 | 425 | 117 | 3.13 / 44.02 | 2 | 11 |
7 | 8 | 0.04 | 165 | 15.25 | 322 | 810 | 3.94 / 44.83 | 2 | 9 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 30 | 15.22 | 454 | 207 | 0.21 / 37.18 | 2 | 3 |
2 | 3 | 1016.64 | 1 | 15.27 | 1707 | 26 | 0.23 / 37.20 | 2 | 5 |
3 | 7 | 2008.56 | 38 | 14.96 | 2823 | 1605 | 1.84 / 38.81 | 2 | 6 |
4 | 13 | 1313.72 | 18 | 15.03 | 2011 | 544 | 2.38 / 39.35 | 2 | 9 |
5 | 13 | 787.16 | 18 | 15.12 | 1367 | 372 | 2.75 / 39.72 | 2 | 11 |
6 | 13 | 357.68 | 18 | 15.21 | 825 | 226 | 2.98 / 39.95 | 2 | 11 |
7 | 13 | 27.76 | 18 | 15.29 | 382 | 105 | 3.09 / 40.05 | 2 | 7 |
8 | 8 | 0.08 | 165 | 15.24 | 331 | 832 | 3.92 / 40.89 | 2 | 12 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 30 | 15.22 | 431 | 197 | 0.20 / 32.55 | 2 | 4 |
2 | 3 | 1025.12 | 1 | 15.30 | 1736 | 27 | 0.22 / 32.58 | 2 | 6 |
3 | 7 | 2005.52 | 74 | 14.84 | 2800 | 3075 | 3.30 / 35.66 | 2 | 7 |
4 | 13 | 635.60 | 18 | 15.17 | 1165 | 318 | 3.62 / 35.97 | 2 | 11 |
5 | 13 | 135.96 | 18 | 15.28 | 497 | 137 | 3.75 / 36.11 | 2 | 11 |
6 | 13 | 15.44 | 18 | 15.31 | 324 | 89 | 3.84 / 36.20 | 2 | 5 |
7 | 8 | -0.12 | 165 | 15.27 | 305 | 768 | 4.61 / 36.97 | 2 | 9 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 30 | 15.23 | 450 | 206 | 0.21 / 28.10 | 2 | 3 |
2 | 7 | 2004.04 | 74 | 14.85 | 2798 | 3075 | 3.28 / 31.17 | 2 | 7 |
3 | 13 | 580.20 | 18 | 15.18 | 1088 | 297 | 3.58 / 31.47 | 2 | 11 |
4 | 13 | 131.56 | 18 | 15.29 | 495 | 136 | 3.71 / 31.60 | 2 | 11 |
5 | 8 | 0.16 | 165 | 15.28 | 299 | 754 | 4.47 / 32.36 | 2 | 8 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 30 | 15.23 | 450 | 206 | 0.21 / 23.93 | 2 | 4 |
2 | 7 | 1790.28 | 75 | 14.91 | 2543 | 2844 | 3.05 / 26.77 | 2 | 7 |
3 | 13 | 459.04 | 18 | 15.22 | 932 | 255 | 3.30 / 27.03 | 2 | 10 |
4 | 13 | 63.60 | 18 | 15.30 | 402 | 111 | 3.42 / 27.14 | 2 | 11 |
5 | 8 | 0.04 | 165 | 15.28 | 297 | 749 | 4.16 / 27.89 | 2 | 10 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 29 | 15.24 | 429 | 190 | 0.19 / 19.81 | 2 | 3 |
2 | 3 | 1017.12 | 1 | 15.31 | 1710 | 26 | 0.22 / 19.84 | 2 | 5 |
3 | 7 | 1761.40 | 74 | 14.92 | 2510 | 2771 | 2.99 / 22.61 | 2 | 7 |
4 | 13 | 469.40 | 18 | 15.22 | 941 | 258 | 3.24 / 22.87 | 2 | 10 |
5 | 13 | 77.24 | 18 | 15.30 | 417 | 115 | 3.36 / 22.98 | 2 | 10 |
6 | 8 | 0.00 | 165 | 15.27 | 295 | 743 | 4.10 / 23.73 | 2 | 8 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 29 | 15.25 | 449 | 199 | 0.20 / 15.72 | 2 | 3 |
2 | 7 | 1758.44 | 74 | 14.92 | 2504 | 2765 | 2.96 / 18.48 | 2 | 8 |
3 | 13 | 506.40 | 18 | 15.21 | 988 | 270 | 3.23 / 18.75 | 2 | 10 |
4 | 13 | 109.84 | 18 | 15.30 | 460 | 127 | 3.36 / 18.88 | 2 | 11 |
5 | 8 | 0.12 | 165 | 15.29 | 295 | 744 | 4.10 / 19.62 | 2 | 10 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 29 | 15.24 | 448 | 198 | 0.20 / 11.95 | 2 | 3 |
2 | 7 | 1510.48 | 75 | 15.01 | 2206 | 2483 | 2.68 / 14.43 | 2 | 9 |
3 | 13 | 411.00 | 18 | 15.25 | 862 | 237 | 2.92 / 14.67 | 2 | 10 |
4 | 13 | 37.08 | 18 | 15.33 | 355 | 98 | 3.02 / 14.77 | 2 | 9 |
5 | 8 | 0.12 | 165 | 15.29 | 297 | 749 | 3.77 / 15.52 | 2 | 8 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 28 | 15.23 | 456 | 194 | 0.19 / 8.17 | 2 | 3 |
2 | 3 | 1033.04 | 1 | 15.28 | 1738 | 27 | 0.22 / 8.19 | 2 | 7 |
3 | 7 | 1521.68 | 74 | 15.00 | 2224 | 2469 | 2.69 / 10.66 | 2 | 8 |
4 | 13 | 434.80 | 18 | 15.24 | 894 | 245 | 2.93 / 10.91 | 2 | 11 |
5 | 13 | 48.84 | 18 | 15.31 | 375 | 103 | 3.04 / 11.01 | 2 | 10 |
6 | 8 | 0.04 | 165 | 15.28 | 295 | 744 | 3.78 / 11.75 | 2 | 7 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 32 | 15.31 | 452 | 221 | 0.22 / 4.45 | 2 | 3 |
2 | 3 | 893.04 | -2 | 15.66 | 0 | 0 | 0.00 / 4.45 | 2 | 3 |
3 | 3 | 950.00 | -1 | 15.68 | 0 | 0 | 0.00 / 4.45 | 2 | 3 |
4 | 7 | 1507.84 | 74 | 15.01 | 2201 | 2445 | 2.67 / 6.89 | 2 | 8 |
5 | 13 | 372.48 | 18 | 15.25 | 811 | 223 | 2.89 / 7.12 | 2 | 10 |
6 | 13 | 44.72 | 18 | 15.32 | 369 | 102 | 2.99 / 7.22 | 2 | 9 |
7 | 8 | 0.16 | 165 | 15.28 | 298 | 751 | 3.74 / 7.97 | 2 | 8 |
Average= | 2.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 27 | 15.47 | 395 | 165 | 0.16 / 1.65 | 3 | 3 |
2 | 10 | 1003.04 | 3 | 15.34 | 1652 | 76 | 0.24 / 1.72 | 2 | 4 |
3 | 7 | 984.48 | 74 | 15.19 | 1561 | 1755 | 2.00 / 3.48 | 2 | 11 |
4 | 8 | 0.08 | 165 | 15.35 | 296 | 750 | 2.75 / 4.23 | 2 | 11 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 82.32 | 27 | 15.63 | 356 | 150 | 0.15 / 0.15 | 3 | 3 |
2 | 7 | 98.84 | 74 | 15.59 | 376 | 434 | 0.58 / 0.58 | 3 | 3 |
3 | 8 | 0.12 | 240 | 15.55 | 241 | 899 | 1.48 / 1.48 | 2 | 12 |
Average= | 1.48 (KJ/cycle) |