SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 31 | 15.16 | 524 | 246 | 0.25 / 90.59 | 2 | 6 |
2 | 7 | 2009.68 | 38 | 14.91 | 2908 | 1648 | 1.89 / 92.23 | 2 | 9 |
3 | 13 | 1358.00 | 18 | 14.99 | 2162 | 583 | 2.48 / 92.82 | 2 | 13 |
4 | 13 | 836.36 | 18 | 15.08 | 1510 | 410 | 2.89 / 93.23 | 2 | 15 |
5 | 13 | 353.00 | 18 | 15.20 | 874 | 239 | 3.13 / 93.47 | 2 | 17 |
6 | 13 | 46.60 | 18 | 15.27 | 444 | 122 | 3.25 / 93.59 | 2 | 16 |
7 | 8 | -0.08 | 165 | 15.22 | 367 | 922 | 4.17 / 94.51 | 2 | 24 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 31 | 15.19 | 511 | 241 | 0.24 / 86.32 | 2 | 6 |
2 | 7 | 2003.04 | 39 | 14.91 | 2905 | 1689 | 1.93 / 88.01 | 2 | 10 |
3 | 13 | 1409.48 | 18 | 15.00 | 2228 | 602 | 2.53 / 88.61 | 2 | 13 |
4 | 13 | 900.12 | 18 | 15.06 | 1591 | 431 | 2.96 / 89.04 | 2 | 16 |
5 | 13 | 354.24 | 18 | 15.19 | 869 | 238 | 3.20 / 89.28 | 2 | 17 |
6 | 13 | 45.76 | 18 | 15.27 | 446 | 123 | 3.32 / 89.40 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.22 | 373 | 937 | 4.26 / 90.34 | 2 | 19 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 31 | 15.19 | 515 | 243 | 0.24 / 81.93 | 2 | 6 |
2 | 7 | 2004.68 | 39 | 14.91 | 2917 | 1696 | 1.94 / 83.63 | 2 | 10 |
3 | 13 | 1365.28 | 18 | 14.97 | 2173 | 586 | 2.52 / 84.22 | 2 | 14 |
4 | 13 | 829.96 | 18 | 15.07 | 1503 | 408 | 2.93 / 84.62 | 2 | 16 |
5 | 13 | 347.28 | 18 | 15.18 | 855 | 234 | 3.17 / 84.86 | 2 | 17 |
6 | 13 | 47.52 | 18 | 15.26 | 446 | 123 | 3.29 / 84.98 | 2 | 17 |
7 | 8 | 0.04 | 165 | 15.23 | 372 | 935 | 4.22 / 85.91 | 2 | 24 |
8 | 14 | 0.04 | 30 | 15.20 | 362 | 165 | 4.39 / 86.08 | 3 | 18 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 31 | 15.20 | 507 | 239 | 0.24 / 77.73 | 2 | 7 |
2 | 7 | 2003.24 | 38 | 14.91 | 2904 | 1645 | 1.88 / 79.38 | 2 | 11 |
3 | 13 | 1375.32 | 18 | 14.99 | 2192 | 591 | 2.48 / 79.97 | 2 | 13 |
4 | 13 | 837.96 | 18 | 15.09 | 1511 | 410 | 2.89 / 80.38 | 2 | 15 |
5 | 13 | 404.36 | 18 | 15.17 | 950 | 259 | 3.15 / 80.64 | 2 | 17 |
6 | 13 | 50.52 | 18 | 15.28 | 452 | 124 | 3.27 / 80.77 | 2 | 17 |
7 | 8 | -0.12 | 165 | 15.25 | 368 | 926 | 4.20 / 81.69 | 2 | 21 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 31 | 15.21 | 504 | 238 | 0.24 / 73.58 | 2 | 6 |
2 | 7 | 2003.36 | 38 | 14.92 | 2912 | 1651 | 1.89 / 75.24 | 2 | 10 |
3 | 13 | 1352.60 | 18 | 15.00 | 2158 | 583 | 2.47 / 75.82 | 2 | 13 |
4 | 13 | 804.76 | 18 | 15.12 | 1460 | 397 | 2.87 / 76.22 | 2 | 15 |
5 | 13 | 323.52 | 18 | 15.22 | 834 | 228 | 3.10 / 76.44 | 2 | 17 |
6 | 13 | 35.36 | 18 | 15.29 | 429 | 118 | 3.22 / 76.56 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.25 | 371 | 934 | 4.15 / 77.50 | 2 | 20 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 31 | 15.21 | 500 | 236 | 0.24 / 69.46 | 3 | 6 |
2 | 7 | 2012.48 | 38 | 14.93 | 2923 | 1658 | 1.89 / 71.12 | 2 | 10 |
3 | 13 | 1368.48 | 18 | 15.01 | 2176 | 588 | 2.48 / 71.71 | 2 | 14 |
4 | 13 | 749.48 | 18 | 15.12 | 1400 | 381 | 2.86 / 72.09 | 2 | 16 |
5 | 13 | 327.24 | 18 | 15.22 | 834 | 228 | 3.09 / 72.32 | 2 | 17 |
6 | 13 | 36.12 | 18 | 15.27 | 436 | 120 | 3.21 / 72.44 | 2 | 17 |
7 | 8 | 0.32 | 165 | 15.24 | 361 | 908 | 4.12 / 73.35 | 2 | 22 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 31 | 15.20 | 505 | 238 | 0.24 / 65.31 | 3 | 4 |
2 | 7 | 2004.60 | 38 | 14.95 | 2915 | 1656 | 1.89 / 66.97 | 2 | 9 |
3 | 13 | 1345.84 | 18 | 15.01 | 2143 | 579 | 2.47 / 67.55 | 2 | 13 |
4 | 13 | 869.40 | 18 | 15.08 | 1554 | 422 | 2.89 / 67.97 | 2 | 15 |
5 | 13 | 325.80 | 18 | 15.22 | 832 | 228 | 3.12 / 68.20 | 2 | 17 |
6 | 13 | 37.28 | 18 | 15.30 | 429 | 118 | 3.24 / 68.32 | 2 | 16 |
7 | 8 | -0.20 | 165 | 15.24 | 362 | 910 | 4.15 / 69.23 | 2 | 23 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 15.22 | 497 | 234 | 0.23 / 60.99 | 3 | 4 |
2 | 7 | 2005.36 | 38 | 14.93 | 2924 | 1659 | 1.89 / 62.65 | 2 | 9 |
3 | 13 | 1318.36 | 18 | 15.02 | 2112 | 571 | 2.46 / 63.22 | 2 | 13 |
4 | 13 | 887.76 | 18 | 15.09 | 1572 | 427 | 2.89 / 63.64 | 2 | 15 |
5 | 13 | 383.88 | 18 | 15.21 | 913 | 250 | 3.14 / 63.89 | 2 | 17 |
6 | 13 | 38.04 | 18 | 15.28 | 433 | 119 | 3.26 / 64.01 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.24 | 359 | 903 | 4.16 / 64.92 | 2 | 21 |
8 | 14 | 0.12 | 30 | 15.21 | 351 | 160 | 4.32 / 65.08 | 3 | 24 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 31 | 15.21 | 500 | 236 | 0.24 / 56.85 | 2 | 6 |
2 | 7 | 2010.28 | 38 | 14.93 | 2921 | 1657 | 1.89 / 58.50 | 2 | 10 |
3 | 13 | 1348.84 | 18 | 15.01 | 2155 | 582 | 2.48 / 59.09 | 2 | 13 |
4 | 13 | 819.84 | 18 | 15.10 | 1489 | 405 | 2.88 / 59.49 | 2 | 16 |
5 | 13 | 333.00 | 18 | 15.23 | 841 | 231 | 3.11 / 59.72 | 2 | 17 |
6 | 13 | 33.96 | 18 | 15.30 | 429 | 118 | 3.23 / 59.84 | 2 | 16 |
7 | 8 | 0.16 | 165 | 15.25 | 363 | 913 | 4.14 / 60.75 | 2 | 20 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 31 | 15.23 | 509 | 240 | 0.24 / 52.70 | 3 | 5 |
2 | 7 | 2002.84 | 38 | 14.95 | 2912 | 1654 | 1.89 / 54.35 | 2 | 10 |
3 | 13 | 1380.76 | 18 | 15.00 | 2191 | 592 | 2.49 / 54.94 | 2 | 13 |
4 | 13 | 839.96 | 18 | 15.09 | 1519 | 413 | 2.90 / 55.36 | 2 | 16 |
5 | 13 | 305.84 | 18 | 15.24 | 810 | 222 | 3.12 / 55.58 | 2 | 17 |
6 | 13 | 29.52 | 18 | 15.32 | 420 | 116 | 3.24 / 55.69 | 2 | 16 |
7 | 8 | 0.20 | 165 | 15.25 | 365 | 918 | 4.16 / 56.61 | 2 | 22 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 31 | 15.22 | 512 | 242 | 0.24 / 48.49 | 3 | 5 |
2 | 3 | 1017.64 | 1 | 15.26 | 1801 | 27 | 0.27 / 48.52 | 2 | 8 |
3 | 7 | 2010.88 | 38 | 14.95 | 2910 | 1653 | 1.92 / 50.17 | 2 | 9 |
4 | 13 | 1448.72 | 18 | 15.00 | 2269 | 613 | 2.53 / 50.79 | 2 | 12 |
5 | 13 | 811.04 | 18 | 15.12 | 1474 | 401 | 2.94 / 51.19 | 2 | 15 |
6 | 13 | 330.76 | 18 | 15.24 | 847 | 232 | 3.17 / 51.42 | 2 | 17 |
7 | 13 | 34.64 | 18 | 15.29 | 431 | 119 | 3.29 / 51.54 | 2 | 16 |
8 | 8 | 0.00 | 165 | 15.25 | 365 | 918 | 4.21 / 52.46 | 2 | 21 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 31 | 15.22 | 485 | 229 | 0.23 / 44.36 | 3 | 5 |
2 | 7 | 2006.28 | 38 | 14.94 | 2891 | 1641 | 1.87 / 46.00 | 2 | 10 |
3 | 13 | 1357.00 | 18 | 15.03 | 2154 | 583 | 2.45 / 46.59 | 2 | 14 |
4 | 13 | 825.44 | 18 | 15.11 | 1490 | 405 | 2.86 / 46.99 | 2 | 16 |
5 | 13 | 336.68 | 18 | 15.23 | 848 | 232 | 3.09 / 47.22 | 2 | 17 |
6 | 13 | 35.36 | 18 | 15.31 | 427 | 118 | 3.21 / 47.34 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.26 | 361 | 909 | 4.12 / 48.25 | 2 | 19 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 30 | 15.24 | 494 | 226 | 0.23 / 40.27 | 3 | 4 |
2 | 7 | 2004.60 | 38 | 14.94 | 2892 | 1642 | 1.87 / 41.91 | 2 | 9 |
3 | 13 | 1382.88 | 18 | 15.03 | 2179 | 590 | 2.46 / 42.50 | 2 | 13 |
4 | 13 | 849.40 | 18 | 15.10 | 1509 | 410 | 2.87 / 42.91 | 2 | 15 |
5 | 13 | 318.20 | 18 | 15.25 | 809 | 222 | 3.09 / 43.13 | 2 | 17 |
6 | 13 | 35.16 | 18 | 15.31 | 417 | 115 | 3.20 / 43.25 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.26 | 352 | 886 | 4.09 / 44.13 | 2 | 22 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 15.24 | 493 | 225 | 0.23 / 35.48 | 2 | 5 |
2 | 3 | 1025.96 | 1 | 15.28 | 1824 | 28 | 0.25 / 35.51 | 2 | 11 |
3 | 7 | 2010.48 | 74 | 14.83 | 2887 | 3168 | 3.42 / 38.67 | 2 | 12 |
4 | 13 | 549.68 | 18 | 15.19 | 1127 | 308 | 3.73 / 38.98 | 2 | 17 |
5 | 13 | 117.48 | 18 | 15.29 | 543 | 149 | 3.88 / 39.13 | 2 | 17 |
6 | 8 | -0.04 | 165 | 15.27 | 362 | 912 | 4.79 / 40.04 | 2 | 21 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 30 | 15.24 | 488 | 223 | 0.22 / 30.61 | 2 | 4 |
2 | 7 | 2003.36 | 74 | 14.88 | 2878 | 3169 | 3.39 / 33.78 | 2 | 11 |
3 | 13 | 578.28 | 18 | 15.20 | 1146 | 314 | 3.71 / 34.09 | 2 | 17 |
4 | 13 | 132.08 | 18 | 15.29 | 553 | 152 | 3.86 / 34.25 | 2 | 17 |
5 | 13 | 14.80 | 18 | 15.31 | 393 | 108 | 3.97 / 34.35 | 2 | 16 |
6 | 8 | 0.16 | 165 | 15.29 | 356 | 898 | 4.86 / 35.25 | 2 | 22 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.04 | 30 | 15.21 | 518 | 236 | 0.24 / 26.13 | 2 | 5 |
2 | 7 | 1808.44 | 74 | 14.91 | 2652 | 2926 | 3.16 / 29.05 | 2 | 11 |
3 | 13 | 542.44 | 18 | 15.20 | 1095 | 300 | 3.46 / 29.35 | 2 | 16 |
4 | 13 | 95.92 | 18 | 15.34 | 498 | 138 | 3.60 / 29.49 | 2 | 17 |
5 | 8 | 0.16 | 165 | 15.29 | 356 | 898 | 4.50 / 30.39 | 2 | 21 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 15.22 | 491 | 217 | 0.22 / 21.61 | 2 | 5 |
2 | 7 | 1818.48 | 74 | 14.88 | 2656 | 2925 | 3.14 / 24.54 | 2 | 11 |
3 | 13 | 556.76 | 18 | 15.20 | 1127 | 308 | 3.45 / 24.84 | 2 | 16 |
4 | 13 | 107.72 | 18 | 15.30 | 523 | 144 | 3.59 / 24.99 | 2 | 17 |
5 | 8 | 0.20 | 165 | 15.26 | 358 | 901 | 4.50 / 25.89 | 2 | 22 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 29 | 15.21 | 495 | 218 | 0.22 / 17.17 | 2 | 5 |
2 | 7 | 1808.20 | 74 | 14.87 | 2646 | 2912 | 3.13 / 20.08 | 2 | 11 |
3 | 13 | 485.48 | 18 | 15.18 | 1027 | 281 | 3.41 / 20.36 | 2 | 16 |
4 | 13 | 86.64 | 18 | 15.29 | 491 | 135 | 3.55 / 20.50 | 2 | 17 |
5 | 8 | 0.04 | 165 | 15.27 | 356 | 897 | 4.44 / 21.39 | 2 | 20 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 29 | 15.24 | 490 | 217 | 0.22 / 13.15 | 2 | 5 |
2 | 7 | 1507.20 | 74 | 15.00 | 2295 | 2547 | 2.76 / 15.70 | 2 | 12 |
3 | 13 | 372.52 | 18 | 15.25 | 877 | 241 | 3.00 / 15.94 | 2 | 16 |
4 | 13 | 45.04 | 18 | 15.31 | 433 | 119 | 3.12 / 16.06 | 2 | 16 |
5 | 8 | 0.24 | 165 | 15.27 | 356 | 897 | 4.02 / 16.95 | 2 | 21 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 28 | 15.25 | 512 | 219 | 0.22 / 9.02 | 3 | 5 |
2 | 10 | 1013.08 | 2 | 15.24 | 1780 | 54 | 0.27 / 9.07 | 2 | 9 |
3 | 7 | 1526.96 | 75 | 14.99 | 2316 | 2604 | 2.88 / 11.68 | 2 | 11 |
4 | 13 | 381.60 | 18 | 15.25 | 883 | 242 | 3.12 / 11.92 | 2 | 16 |
5 | 13 | 48.28 | 18 | 15.33 | 433 | 119 | 3.24 / 12.04 | 2 | 16 |
6 | 8 | 0.28 | 165 | 15.29 | 354 | 893 | 4.13 / 12.93 | 2 | 23 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 32 | 15.30 | 492 | 241 | 0.24 / 4.97 | 3 | 5 |
2 | 3 | 880.32 | -2 | 15.65 | 0 | 0 | 0.00 / 4.97 | 3 | 5 |
3 | 3 | 936.48 | -1 | 15.67 | 0 | 0 | 0.00 / 4.97 | 3 | 5 |
4 | 7 | 1509.32 | 75 | 15.01 | 2292 | 2580 | 2.82 / 7.55 | 2 | 11 |
5 | 13 | 409.40 | 18 | 15.24 | 911 | 250 | 3.07 / 7.80 | 2 | 16 |
6 | 13 | 60.44 | 18 | 15.35 | 442 | 122 | 3.19 / 7.92 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.28 | 347 | 875 | 4.07 / 8.80 | 2 | 23 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 27 | 15.43 | 447 | 186 | 0.19 / 1.96 | 3 | 3 |
2 | 3 | 1041.88 | 1 | 15.30 | 1810 | 28 | 0.21 / 1.99 | 2 | 11 |
3 | 7 | 1006.88 | 74 | 15.15 | 1654 | 1854 | 2.07 / 3.84 | 2 | 14 |
4 | 8 | 0.00 | 165 | 15.34 | 351 | 888 | 2.96 / 4.73 | 2 | 23 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 99.04 | 27 | 15.64 | 434 | 183 | 0.18 / 0.18 | 3 | 3 |
2 | 7 | 115.40 | 74 | 15.59 | 446 | 515 | 0.70 / 0.70 | 3 | 5 |
3 | 8 | -0.36 | 240 | 15.53 | 289 | 1077 | 1.77 / 1.77 | 3 | 18 |
Average= | 1.77 (KJ/cycle) |