SIO Argo Site:
Pump Diagnostics Page   



Serial= 3240 WMO= 5906952

Return

←PreviousNext→

Cycle 33 GMT 1/ 4/2025 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 25 15.23 448 171 0.17 / 123.42 2 6
2 7 2005.96 38 14.96 2802 1593 1.76 / 125.01 2 9
3 13 1313.08 18 15.04 1980 536 2.30 / 125.55 2 11
4 13 869.44 18 15.10 1451 394 2.69 / 125.94 2 11
5 13 383.76 18 15.22 835 229 2.92 / 126.17 2 13
6 13 16.72 18 15.31 333 92 3.01 / 126.26 2 13
7 8 0.16 165 15.27 299 753 3.77 / 127.01 2 19
Average= 3.74
(KJ/cycle)

Cycle 32 GMT 22/ 3/2025 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 26 15.22 448 177 0.18 / 119.63 2 6
2 3 972.12 -1 15.56 0 0 0.00 / 119.63 2 6
3 3 1024.32 1 15.29 1694 26 0.20 / 119.66 2 9
4 7 2008.60 39 14.95 2812 1640 1.84 / 121.30 2 8
5 13 1372.60 18 15.02 2057 556 2.40 / 121.85 2 10
6 13 875.88 18 15.10 1460 397 2.80 / 122.25 2 12
7 13 390.88 18 15.21 843 231 3.03 / 122.48 2 12
8 8 0.04 165 15.27 304 766 3.79 / 123.25 2 21
Average= 3.73
(KJ/cycle)

Cycle 31 GMT 12/ 3/2025 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 26 15.23 464 184 0.18 / 115.95 2 6
2 3 1017.24 1 15.26 1694 26 0.21 / 115.97 2 8
3 7 2004.28 38 14.95 2808 1595 1.80 / 117.57 2 8
4 13 1347.44 18 15.03 2038 551 2.36 / 118.12 2 10
5 13 774.52 18 15.13 1332 363 2.72 / 118.48 2 12
6 13 359.00 18 15.21 800 219 2.94 / 118.70 2 12
7 8 0.16 165 15.26 300 755 3.69 / 119.45 2 16
Average= 3.73
(KJ/cycle)

Cycle 30 GMT 2/ 3/2025 17:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 26 15.24 450 178 0.18 / 112.27 2 6
2 7 2002.96 38 14.97 2793 1589 1.77 / 113.86 2 7
3 13 1375.20 18 15.04 2059 557 2.32 / 114.41 2 10
4 13 800.76 18 15.13 1364 371 2.70 / 114.79 2 12
5 13 362.08 18 15.23 802 220 2.92 / 115.01 2 13
6 8 0.20 165 15.27 300 756 3.67 / 115.76 2 20
Average= 3.73
(KJ/cycle)

Cycle 29 GMT 20/ 2/2025 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 25 15.21 456 173 0.17 / 108.60 2 6
2 3 1017.68 1 15.25 1692 26 0.20 / 108.63 2 7
3 7 2006.68 38 14.97 2798 1592 1.79 / 110.22 2 7
4 13 1298.52 18 15.06 1972 535 2.33 / 110.75 2 10
5 13 815.80 18 15.13 1379 376 2.70 / 111.13 2 11
6 13 341.76 18 15.23 776 213 2.91 / 111.34 2 13
7 8 0.12 165 15.28 297 749 3.66 / 112.09 2 24
Average= 3.74
(KJ/cycle)

Cycle 28 GMT 11/ 2/2025 2:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 25 15.22 459 175 0.17 / 104.95 2 6
2 7 2011.64 38 14.98 2815 1602 1.78 / 106.56 2 9
3 13 1305.16 18 15.06 1977 536 2.31 / 107.09 2 10
4 13 754.96 18 15.14 1307 356 2.67 / 107.45 2 12
5 13 382.32 18 15.21 829 227 2.90 / 107.67 2 12
6 8 0.08 165 15.26 299 753 3.65 / 108.43 2 17
Average= 3.74
(KJ/cycle)

Cycle 27 GMT 1/ 2/2025 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 15.23 464 184 0.18 / 101.29 2 6
2 7 2007.20 38 14.97 2804 1595 1.78 / 102.88 2 8
3 13 1270.48 18 15.05 1939 525 2.30 / 103.41 2 10
4 13 882.32 18 15.12 1473 401 2.70 / 103.81 2 12
5 13 332.20 18 15.23 766 210 2.91 / 104.02 2 13
6 8 0.04 165 15.28 301 759 3.67 / 104.78 2 18
Average= 3.74
(KJ/cycle)

Cycle 26 GMT 22/ 1/2025 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 26 15.25 450 178 0.18 / 97.48 2 5
2 7 2012.84 38 14.99 2815 1603 1.78 / 99.08 2 8
3 13 1451.96 18 15.04 2159 584 2.37 / 99.67 2 10
4 13 989.84 18 15.11 1597 434 2.80 / 100.10 2 12
5 13 426.00 18 15.22 893 245 3.05 / 100.34 2 14
6 8 0.40 165 15.29 301 759 3.80 / 101.10 2 20
Average= 3.74
(KJ/cycle)

Cycle 25 GMT 12/ 1/2025 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 26 15.24 451 179 0.18 / 93.81 2 6
2 7 2009.44 38 14.98 2805 1597 1.78 / 95.40 2 7
3 13 1340.08 18 15.06 2020 548 2.32 / 95.95 2 10
4 13 807.84 18 15.16 1377 376 2.70 / 96.33 2 12
5 13 342.20 18 15.26 779 214 2.91 / 96.54 2 12
6 8 0.56 165 15.28 301 759 3.67 / 97.30 2 19
Average= 3.74
(KJ/cycle)

Cycle 24 GMT 2/ 1/2025 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 27 15.24 456 188 0.19 / 90.11 2 5
2 3 968.52 -1 15.59 0 0 0.00 / 90.11 2 5
3 7 2003.64 39 14.97 2793 1631 1.82 / 91.74 2 9
4 13 1314.72 18 15.06 1985 538 2.36 / 92.28 2 10
5 13 803.24 18 15.14 1370 373 2.73 / 92.65 2 13
6 13 370.32 18 15.23 813 223 2.95 / 92.87 2 12
7 8 0.32 165 15.28 299 754 3.71 / 93.63 2 22
Average= 3.75
(KJ/cycle)

Cycle 23 GMT 24/12/2024 2:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 27 15.24 457 188 0.19 / 86.43 2 5
2 7 2004.16 38 14.98 2809 1599 1.79 / 88.03 2 8
3 13 1358.84 18 15.06 2049 555 2.34 / 88.59 2 10
4 13 824.88 18 15.14 1411 385 2.73 / 88.97 2 13
5 13 306.48 18 15.26 737 202 2.93 / 89.17 2 12
6 8 0.08 165 15.28 297 749 3.68 / 89.92 2 21
Average= 3.75
(KJ/cycle)

Cycle 22 GMT 14/12/2024 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 27 15.24 456 188 0.19 / 82.74 2 5
2 7 2002.88 38 14.98 2793 1590 1.78 / 84.33 2 7
3 13 1305.12 18 15.07 1975 536 2.31 / 84.86 2 10
4 13 823.52 18 15.13 1396 380 2.69 / 85.24 2 12
5 13 432.08 18 15.22 899 246 2.94 / 85.49 2 13
6 8 0.28 165 15.29 299 754 3.69 / 86.24 2 21
Average= 3.75
(KJ/cycle)

Cycle 21 GMT 4/12/2024 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 27 15.24 444 183 0.18 / 78.99 2 4
2 7 2003.92 39 14.98 2796 1633 1.82 / 80.62 2 7
3 13 1364.44 18 15.06 2054 557 2.37 / 81.18 2 10
4 13 828.80 18 15.14 1408 384 2.76 / 81.56 2 12
5 13 385.24 18 15.24 836 229 2.99 / 81.79 2 13
6 8 -0.16 165 15.29 300 757 3.74 / 82.55 2 20
Average= 3.75
(KJ/cycle)

Cycle 20 GMT 24/11/2024 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 15.25 444 190 0.19 / 75.21 3 4
2 7 2010.20 38 14.99 2804 1597 1.79 / 76.81 2 7
3 13 1365.68 18 15.06 2049 555 2.34 / 77.36 2 10
4 13 845.12 18 15.14 1422 388 2.73 / 77.75 2 12
5 13 314.16 18 15.26 747 205 2.93 / 77.96 2 12
6 13 23.20 18 15.32 345 95 3.03 / 78.05 2 12
7 8 -0.20 165 15.28 299 754 3.78 / 78.81 2 18
Average= 3.75
(KJ/cycle)

Cycle 19 GMT 14/11/2024 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 15.23 444 189 0.19 / 71.31 2 4
2 7 2004.60 38 15.00 2801 1597 1.79 / 72.90 2 9
3 13 1424.68 18 15.06 2132 578 2.36 / 73.48 2 11
4 13 1054.96 18 15.11 1676 456 2.82 / 73.94 2 11
5 13 427.96 18 15.24 890 244 3.06 / 74.18 2 12
6 13 23.72 18 15.33 343 95 3.16 / 74.28 2 11
7 8 0.32 165 15.29 296 747 3.91 / 75.02 2 20
Average= 3.75
(KJ/cycle)

Cycle 18 GMT 5/11/2024 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 28 15.22 445 190 0.19 / 67.47 2 4
2 7 2004.88 38 15.01 2805 1600 1.79 / 69.07 2 8
3 13 1361.52 18 15.08 2049 556 2.35 / 69.63 2 10
4 13 881.96 18 15.14 1464 399 2.74 / 70.03 2 12
5 13 405.96 18 15.25 865 237 2.98 / 70.27 2 12
6 13 39.56 18 15.32 368 101 3.08 / 70.37 2 12
7 8 -0.20 165 15.29 297 749 3.83 / 71.12 2 18
Average= 3.74
(KJ/cycle)

Cycle 17 GMT 26/10/2024 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 29 15.25 433 191 0.19 / 63.68 2 3
2 7 2003.92 38 15.00 2801 1597 1.79 / 65.28 2 7
3 13 1289.00 18 15.09 1964 533 2.32 / 65.81 2 10
4 13 871.00 18 15.14 1451 395 2.72 / 66.21 2 12
5 13 380.48 18 15.25 834 229 2.95 / 66.44 2 12
6 13 28.76 18 15.31 350 96 3.04 / 66.53 2 12
7 8 0.20 165 15.29 297 749 3.79 / 67.28 2 18
Average= 3.74
(KJ/cycle)

Cycle 16 GMT 16/10/2024 11:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 29 15.24 438 194 0.19 / 59.87 3 4
2 7 2007.84 38 15.01 2803 1599 1.79 / 61.47 2 9
3 13 1395.08 18 15.08 2090 567 2.36 / 62.04 2 10
4 13 890.84 18 15.15 1473 402 2.76 / 62.44 2 13
5 13 343.76 18 15.28 781 215 2.98 / 62.65 2 13
6 13 40.72 18 15.34 359 99 3.08 / 62.75 2 12
7 8 0.12 165 15.30 293 740 3.81 / 63.49 2 20
Average= 3.73
(KJ/cycle)

Cycle 15 GMT 6/10/2024 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 29 15.24 448 198 0.20 / 56.09 3 3
2 7 2007.08 38 15.01 2807 1601 1.80 / 57.69 2 9
3 13 1330.12 18 15.08 2014 547 2.35 / 58.24 2 11
4 13 805.08 18 15.16 1370 374 2.72 / 58.61 2 12
5 13 365.84 18 15.26 810 222 2.94 / 58.84 2 12
6 13 43.64 18 15.33 371 102 3.04 / 58.94 2 12
7 8 0.00 165 15.29 293 739 3.78 / 59.68 2 18
Average= 3.73
(KJ/cycle)

Cycle 14 GMT 26/ 9/2024 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 29 15.25 445 197 0.20 / 52.25 3 3
2 7 2010.40 38 15.00 2803 1598 1.79 / 53.85 2 7
3 13 1357.60 18 15.08 2050 556 2.35 / 54.41 2 10
4 13 930.12 18 15.14 1522 415 2.77 / 54.82 2 12
5 13 383.00 18 15.26 832 229 2.99 / 55.05 2 12
6 13 32.60 18 15.33 357 99 3.09 / 55.15 2 12
7 8 0.20 165 15.29 296 747 3.84 / 55.89 2 19
Average= 3.73
(KJ/cycle)

Cycle 13 GMT 17/ 9/2024 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 29 15.26 435 193 0.19 / 48.40 2 4
2 7 2010.68 38 15.01 2810 1603 1.80 / 50.00 2 8
3 13 1372.84 18 15.09 2056 558 2.35 / 50.56 2 10
4 13 931.68 18 15.14 1531 417 2.77 / 50.98 2 11
5 13 415.12 18 15.26 871 239 3.01 / 51.22 2 13
6 13 31.60 18 15.34 353 97 3.11 / 51.31 2 11
7 8 0.04 165 15.30 293 740 3.85 / 52.05 2 19
Average= 3.72
(KJ/cycle)

Cycle 12 GMT 7/ 9/2024 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 28 15.23 441 188 0.19 / 44.47 3 3
2 7 2009.96 39 15.01 2815 1648 1.84 / 46.12 2 7
3 13 1433.56 18 15.07 2141 581 2.42 / 46.70 2 10
4 13 922.36 18 15.15 1516 413 2.83 / 47.12 2 12
5 13 414.24 18 15.26 878 241 3.07 / 47.36 2 13
6 13 37.40 18 15.34 365 101 3.17 / 47.46 2 12
7 8 0.08 165 15.30 297 750 3.92 / 48.21 2 20
Average= 3.71
(KJ/cycle)

Cycle 11 GMT 28/ 8/2024 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 28 15.26 442 189 0.19 / 40.74 3 3
2 7 2008.36 38 14.99 2802 1596 1.78 / 42.34 2 8
3 13 1305.44 18 15.08 1982 538 2.32 / 42.88 2 10
4 13 784.16 18 15.17 1347 368 2.69 / 43.24 2 12
5 13 316.96 18 15.28 745 205 2.90 / 43.45 2 13
6 13 27.28 18 15.32 346 95 2.99 / 43.54 2 12
7 8 -0.04 165 15.28 294 741 3.73 / 44.29 2 19
Average= 3.69
(KJ/cycle)

Cycle 10 GMT 18/ 8/2024 16: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 28 15.26 444 190 0.19 / 36.95 3 3
2 7 2003.16 38 15.00 2793 1592 1.78 / 38.54 2 7
3 13 1391.20 18 15.08 2083 565 2.35 / 39.10 2 10
4 13 857.76 18 15.16 1436 392 2.74 / 39.50 2 12
5 13 376.24 18 15.27 818 225 2.96 / 39.72 2 12
6 13 33.84 18 15.34 353 97 3.06 / 39.82 2 11
7 8 0.20 165 15.29 291 734 3.80 / 40.55 2 16
Average= 3.69
(KJ/cycle)

Cycle 9 GMT 8/ 8/2024 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 27 15.28 444 183 0.18 / 32.51 3 3
2 3 1037.08 1 15.35 1712 26 0.21 / 32.53 2 8
3 7 2004.40 74 14.89 2782 3065 3.27 / 35.60 2 8
4 13 623.52 18 15.22 1135 311 3.59 / 35.91 2 12
5 13 64.28 18 15.34 394 109 3.69 / 36.02 2 12
6 8 -0.08 165 15.31 292 738 4.43 / 36.76 2 16
Average= 3.68
(KJ/cycle)

Cycle 8 GMT 29/ 7/2024 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 15.28 424 194 0.19 / 28.12 2 4
2 3 891.24 -2 15.69 0 0 0.00 / 28.12 2 4
3 7 2003.80 74 14.91 2779 3066 3.26 / 31.19 2 8
4 13 573.64 18 15.24 1077 295 3.56 / 31.49 2 12
5 13 45.00 18 15.35 369 102 3.66 / 31.59 2 11
6 8 0.08 165 15.32 292 738 4.40 / 32.33 2 19
Average= 3.59
(KJ/cycle)

Cycle 7 GMT 20/ 7/2024 2:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 15.28 437 180 0.18 / 24.01 2 4
2 7 1805.84 74 14.96 2546 2819 3.00 / 26.83 2 8
3 13 492.32 18 15.27 967 266 3.26 / 27.09 2 12
4 13 26.32 18 15.36 340 94 3.36 / 27.19 2 12
5 8 0.16 165 15.33 294 744 4.10 / 27.93 2 19
Average= 3.49
(KJ/cycle)

Cycle 6 GMT 19/ 7/2024 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 26 15.28 438 174 0.17 / 19.86 2 3
2 7 1817.08 74 14.96 2560 2834 3.01 / 22.70 2 9
3 13 562.36 18 15.25 1062 292 3.30 / 22.99 2 13
4 13 27.84 18 15.35 343 95 3.39 / 23.08 2 12
5 8 0.08 165 15.31 295 745 4.14 / 23.83 2 19
Average= 3.40
(KJ/cycle)

Cycle 5 GMT 18/ 7/2024 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 26 15.29 434 173 0.17 / 15.69 2 4
2 7 1812.68 75 14.97 2554 2868 3.04 / 18.55 2 8
3 13 582.64 18 15.24 1089 299 3.34 / 18.85 2 12
4 13 17.56 18 15.36 331 92 3.43 / 18.94 2 11
5 8 0.12 165 15.33 294 744 4.17 / 19.69 2 18
Average= 3.28
(KJ/cycle)

Cycle 4 GMT 17/ 7/2024 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 27 15.28 437 180 0.18 / 11.99 2 4
2 7 1506.92 74 15.09 2192 2448 2.63 / 14.44 2 8
3 13 425.08 18 15.31 875 241 2.87 / 14.68 2 13
4 13 22.24 18 15.37 334 92 2.96 / 14.77 2 11
5 8 0.12 165 15.33 292 739 3.70 / 15.51 2 22
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 16/ 7/2024 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 27 15.28 439 181 0.18 / 8.27 3 4
2 3 972.96 -1 15.68 0 0 0.00 / 8.27 3 4
3 3 1025.44 1 15.38 1699 26 0.21 / 8.29 2 8
4 7 1508.32 74 15.07 2193 2446 2.65 / 10.74 2 9
5 13 405.52 18 15.30 854 235 2.89 / 10.97 2 12
6 13 26.00 18 15.38 341 94 2.98 / 11.07 2 12
7 8 0.04 165 15.33 295 746 3.73 / 11.81 2 20
Average= 2.95
(KJ/cycle)

Cycle 2 GMT 15/ 7/2024 1: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 15.35 440 216 0.22 / 4.51 2 4
2 3 831.36 -3 15.71 0 0 0.00 / 4.51 2 4
3 3 942.32 -1 15.73 0 0 0.00 / 4.51 2 4
4 7 1525.40 74 15.06 2213 2466 2.68 / 6.98 2 9
5 13 477.84 18 15.28 948 261 2.94 / 7.24 2 12
6 13 31.04 18 15.37 352 97 3.04 / 7.33 2 12
7 8 0.04 165 15.33 297 751 3.79 / 8.08 2 19
Average= 2.69
(KJ/cycle)

Cycle 1 GMT 14/ 7/2024 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 27 15.48 400 167 0.17 / 1.79 3 3
2 7 978.44 74 15.25 1544 1742 1.91 / 3.53 2 12
3 8 -0.04 165 15.41 299 760 2.67 / 4.29 2 18
Average= 2.15
(KJ/cycle)

Cycle 0 GMT 13/ 7/2024 14:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 131.16 27 15.64 429 181 0.18 / 0.18 3 3
2 7 147.40 74 15.61 446 515 0.70 / 0.70 3 3
3 8 0.24 240 15.57 248 927 1.62 / 1.62 3 13
Average= 1.62
(KJ/cycle)