SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 32 | 15.19 | 429 | 209 | 0.21 / 82.87 | 2 | 7 |
2 | 7 | 2011.52 | 38 | 14.92 | 2825 | 1602 | 1.81 / 84.47 | 2 | 15 |
3 | 13 | 1319.56 | 18 | 15.00 | 2023 | 546 | 2.36 / 85.02 | 2 | 17 |
4 | 13 | 837.12 | 18 | 15.08 | 1429 | 388 | 2.74 / 85.40 | 2 | 21 |
5 | 13 | 406.88 | 18 | 15.19 | 856 | 234 | 2.98 / 85.64 | 2 | 21 |
6 | 8 | 0.16 | 165 | 15.23 | 299 | 751 | 3.73 / 86.39 | 2 | 27 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 32 | 15.19 | 415 | 202 | 0.20 / 79.11 | 2 | 4 |
2 | 7 | 2007.80 | 38 | 14.94 | 2814 | 1598 | 1.80 / 80.70 | 2 | 14 |
3 | 13 | 1312.92 | 18 | 15.02 | 2007 | 543 | 2.34 / 81.25 | 2 | 19 |
4 | 13 | 849.52 | 18 | 15.09 | 1428 | 388 | 2.73 / 81.63 | 2 | 20 |
5 | 13 | 360.96 | 18 | 15.20 | 790 | 216 | 2.95 / 81.85 | 2 | 20 |
6 | 13 | 20.96 | 18 | 15.26 | 323 | 89 | 3.03 / 81.94 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.23 | 287 | 721 | 3.76 / 82.66 | 2 | 28 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 32 | 15.20 | 443 | 215 | 0.22 / 75.16 | 2 | 6 |
2 | 7 | 2009.08 | 38 | 14.94 | 2813 | 1597 | 1.81 / 76.76 | 2 | 18 |
3 | 13 | 1311.28 | 18 | 15.03 | 1997 | 540 | 2.35 / 77.30 | 2 | 19 |
4 | 13 | 934.52 | 18 | 15.08 | 1535 | 417 | 2.77 / 77.72 | 2 | 20 |
5 | 13 | 435.96 | 18 | 15.19 | 885 | 242 | 3.01 / 77.96 | 2 | 21 |
6 | 13 | 60.44 | 18 | 15.27 | 375 | 103 | 3.11 / 78.06 | 2 | 17 |
7 | 8 | 0.04 | 165 | 15.24 | 284 | 714 | 3.83 / 78.78 | 2 | 25 |
8 | 14 | 0.04 | 30 | 15.21 | 282 | 129 | 3.96 / 78.90 | 3 | 25 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 32 | 15.21 | 420 | 204 | 0.20 / 71.31 | 2 | 6 |
2 | 7 | 2006.20 | 38 | 14.96 | 2817 | 1601 | 1.81 / 72.91 | 2 | 17 |
3 | 13 | 1394.00 | 18 | 15.02 | 2100 | 568 | 2.37 / 73.48 | 2 | 19 |
4 | 13 | 858.52 | 18 | 15.11 | 1439 | 391 | 2.76 / 73.87 | 2 | 20 |
5 | 13 | 461.60 | 18 | 15.19 | 924 | 253 | 3.02 / 74.13 | 2 | 21 |
6 | 13 | 42.68 | 18 | 15.28 | 356 | 98 | 3.12 / 74.22 | 2 | 18 |
7 | 8 | 0.08 | 165 | 15.25 | 287 | 722 | 3.84 / 74.95 | 2 | 24 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 32 | 15.21 | 425 | 207 | 0.21 / 67.48 | 2 | 4 |
2 | 7 | 2003.40 | 39 | 14.96 | 2820 | 1645 | 1.85 / 69.12 | 2 | 14 |
3 | 13 | 1317.96 | 18 | 15.04 | 2014 | 545 | 2.40 / 69.67 | 2 | 19 |
4 | 13 | 829.56 | 18 | 15.12 | 1406 | 383 | 2.78 / 70.05 | 2 | 20 |
5 | 13 | 443.92 | 18 | 15.20 | 901 | 247 | 3.03 / 70.30 | 2 | 21 |
6 | 13 | 36.68 | 18 | 15.29 | 345 | 95 | 3.12 / 70.39 | 2 | 15 |
7 | 8 | 0.12 | 165 | 15.26 | 285 | 718 | 3.84 / 71.11 | 2 | 26 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 32 | 15.21 | 422 | 205 | 0.21 / 63.47 | 2 | 5 |
2 | 7 | 2011.28 | 39 | 14.96 | 2816 | 1643 | 1.85 / 65.11 | 2 | 14 |
3 | 13 | 1396.72 | 18 | 15.02 | 2106 | 569 | 2.42 / 65.68 | 2 | 17 |
4 | 13 | 905.16 | 18 | 15.10 | 1505 | 409 | 2.83 / 66.09 | 2 | 21 |
5 | 13 | 405.56 | 18 | 15.20 | 845 | 231 | 3.06 / 66.32 | 2 | 21 |
6 | 13 | 37.92 | 18 | 15.29 | 339 | 93 | 3.15 / 66.42 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.25 | 287 | 722 | 3.87 / 67.14 | 2 | 28 |
8 | 14 | 0.08 | 30 | 15.23 | 285 | 130 | 4.00 / 67.27 | 3 | 25 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 32 | 15.20 | 399 | 194 | 0.19 / 59.67 | 2 | 4 |
2 | 7 | 2006.56 | 38 | 14.95 | 2813 | 1598 | 1.79 / 61.26 | 2 | 14 |
3 | 13 | 1339.48 | 18 | 15.03 | 2032 | 550 | 2.34 / 61.81 | 2 | 17 |
4 | 13 | 865.40 | 18 | 15.10 | 1451 | 394 | 2.74 / 62.21 | 2 | 20 |
5 | 13 | 427.56 | 18 | 15.20 | 887 | 243 | 2.98 / 62.45 | 2 | 21 |
6 | 13 | 35.04 | 18 | 15.28 | 343 | 94 | 3.07 / 62.54 | 2 | 17 |
7 | 8 | -0.12 | 165 | 15.25 | 287 | 722 | 3.80 / 63.27 | 2 | 21 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 32 | 15.21 | 402 | 196 | 0.20 / 55.84 | 2 | 4 |
2 | 7 | 2003.68 | 38 | 14.96 | 2816 | 1601 | 1.80 / 57.44 | 2 | 13 |
3 | 13 | 1395.68 | 18 | 15.03 | 2108 | 570 | 2.37 / 58.01 | 2 | 17 |
4 | 13 | 877.08 | 18 | 15.10 | 1468 | 399 | 2.77 / 58.41 | 2 | 21 |
5 | 13 | 455.16 | 18 | 15.20 | 920 | 252 | 3.02 / 58.66 | 2 | 21 |
6 | 13 | 45.60 | 18 | 15.28 | 365 | 100 | 3.12 / 58.76 | 2 | 18 |
7 | 8 | 0.08 | 165 | 15.25 | 283 | 712 | 3.83 / 59.47 | 2 | 22 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 32 | 15.21 | 400 | 195 | 0.19 / 52.00 | 2 | 4 |
2 | 7 | 2006.72 | 38 | 14.96 | 2815 | 1600 | 1.79 / 53.60 | 2 | 14 |
3 | 13 | 1475.16 | 18 | 15.03 | 2195 | 594 | 2.39 / 54.20 | 2 | 16 |
4 | 13 | 915.76 | 18 | 15.11 | 1508 | 410 | 2.80 / 54.61 | 2 | 19 |
5 | 13 | 413.40 | 18 | 15.21 | 854 | 234 | 3.03 / 54.84 | 2 | 20 |
6 | 13 | 30.68 | 18 | 15.30 | 331 | 91 | 3.12 / 54.93 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.26 | 282 | 710 | 3.83 / 55.64 | 2 | 20 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 32 | 15.23 | 420 | 205 | 0.20 / 48.18 | 2 | 5 |
2 | 7 | 2011.60 | 38 | 14.97 | 2825 | 1607 | 1.81 / 49.79 | 2 | 16 |
3 | 13 | 1405.84 | 18 | 15.04 | 2124 | 575 | 2.39 / 50.36 | 2 | 18 |
4 | 13 | 924.96 | 18 | 15.10 | 1523 | 414 | 2.80 / 50.78 | 2 | 19 |
5 | 13 | 386.20 | 18 | 15.22 | 822 | 225 | 3.03 / 51.00 | 2 | 20 |
6 | 13 | 40.60 | 18 | 15.30 | 350 | 96 | 3.12 / 51.10 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.26 | 281 | 708 | 3.83 / 51.81 | 2 | 23 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 32 | 15.22 | 421 | 205 | 0.21 / 44.42 | 2 | 4 |
2 | 7 | 2009.16 | 38 | 14.97 | 2812 | 1600 | 1.80 / 46.02 | 2 | 14 |
3 | 13 | 1318.44 | 18 | 15.04 | 2011 | 544 | 2.35 / 46.56 | 2 | 17 |
4 | 13 | 845.72 | 18 | 15.11 | 1423 | 387 | 2.74 / 46.95 | 2 | 19 |
5 | 13 | 377.96 | 18 | 15.22 | 805 | 221 | 2.96 / 47.17 | 2 | 20 |
6 | 13 | 24.44 | 18 | 15.30 | 326 | 90 | 3.05 / 47.26 | 2 | 19 |
7 | 8 | 0.08 | 165 | 15.26 | 286 | 720 | 3.77 / 47.98 | 2 | 26 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 32 | 15.24 | 434 | 212 | 0.21 / 40.62 | 2 | 5 |
2 | 7 | 2004.88 | 38 | 14.97 | 2806 | 1596 | 1.81 / 42.22 | 2 | 17 |
3 | 13 | 1361.96 | 18 | 15.06 | 2056 | 557 | 2.37 / 42.78 | 2 | 19 |
4 | 13 | 868.08 | 18 | 15.13 | 1450 | 395 | 2.76 / 43.17 | 2 | 20 |
5 | 13 | 427.16 | 18 | 15.23 | 875 | 240 | 3.00 / 43.41 | 2 | 21 |
6 | 13 | 31.20 | 18 | 15.31 | 336 | 93 | 3.09 / 43.51 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.26 | 280 | 705 | 3.80 / 44.21 | 2 | 25 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 32 | 15.24 | 434 | 212 | 0.21 / 36.82 | 2 | 6 |
2 | 7 | 2006.60 | 38 | 14.98 | 2805 | 1597 | 1.81 / 38.42 | 2 | 17 |
3 | 13 | 1394.36 | 18 | 15.06 | 2104 | 570 | 2.38 / 38.99 | 2 | 18 |
4 | 13 | 841.84 | 18 | 15.15 | 1417 | 386 | 2.77 / 39.37 | 2 | 20 |
5 | 13 | 400.60 | 18 | 15.24 | 838 | 230 | 3.00 / 39.60 | 2 | 21 |
6 | 13 | 27.40 | 18 | 15.32 | 332 | 92 | 3.09 / 39.69 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.28 | 285 | 719 | 3.81 / 40.41 | 2 | 25 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 31 | 15.26 | 424 | 201 | 0.20 / 32.24 | 2 | 4 |
2 | 3 | 1030.64 | 1 | 15.33 | 1718 | 26 | 0.23 / 32.26 | 2 | 15 |
3 | 7 | 2010.16 | 74 | 14.86 | 2806 | 3086 | 3.31 / 35.35 | 2 | 15 |
4 | 13 | 637.44 | 18 | 15.19 | 1159 | 317 | 3.63 / 35.66 | 2 | 21 |
5 | 13 | 144.08 | 18 | 15.29 | 491 | 135 | 3.76 / 35.80 | 2 | 19 |
6 | 13 | 14.24 | 18 | 15.32 | 317 | 87 | 3.85 / 35.89 | 2 | 19 |
7 | 8 | -0.08 | 165 | 15.28 | 286 | 721 | 4.57 / 36.61 | 2 | 29 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 29 | 15.23 | 424 | 187 | 0.19 / 27.74 | 2 | 6 |
2 | 10 | 1025.08 | 2 | 15.28 | 1689 | 52 | 0.24 / 27.79 | 2 | 13 |
3 | 7 | 2003.68 | 74 | 14.89 | 2793 | 3077 | 3.32 / 30.87 | 2 | 16 |
4 | 13 | 698.88 | 18 | 15.19 | 1233 | 337 | 3.65 / 31.21 | 2 | 21 |
5 | 13 | 44.64 | 18 | 15.35 | 358 | 99 | 3.75 / 31.31 | 2 | 17 |
6 | 8 | 0.12 | 165 | 15.31 | 288 | 728 | 4.48 / 32.03 | 2 | 25 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 15.25 | 403 | 184 | 0.18 / 23.57 | 2 | 6 |
2 | 7 | 1810.72 | 75 | 14.93 | 2564 | 2871 | 3.06 / 26.44 | 2 | 17 |
3 | 13 | 547.32 | 18 | 15.20 | 1037 | 284 | 3.34 / 26.72 | 2 | 21 |
4 | 13 | 44.80 | 18 | 15.32 | 358 | 99 | 3.44 / 26.82 | 2 | 16 |
5 | 8 | -0.04 | 165 | 15.27 | 291 | 733 | 4.17 / 27.55 | 2 | 20 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 30 | 15.26 | 432 | 198 | 0.20 / 19.42 | 2 | 5 |
2 | 7 | 1805.20 | 75 | 14.93 | 2557 | 2863 | 3.06 / 22.29 | 2 | 16 |
3 | 13 | 539.28 | 18 | 15.22 | 1023 | 280 | 3.34 / 22.57 | 2 | 20 |
4 | 13 | 28.08 | 18 | 15.33 | 337 | 93 | 3.43 / 22.66 | 2 | 16 |
5 | 8 | 0.00 | 165 | 15.29 | 287 | 724 | 4.16 / 23.38 | 2 | 30 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 30 | 15.25 | 436 | 199 | 0.20 / 15.71 | 2 | 5 |
2 | 7 | 1507.32 | 74 | 15.05 | 2202 | 2452 | 2.65 / 18.17 | 2 | 16 |
3 | 13 | 434.60 | 18 | 15.27 | 881 | 242 | 2.89 / 18.41 | 2 | 19 |
4 | 13 | 20.48 | 18 | 15.35 | 329 | 91 | 2.98 / 18.50 | 2 | 19 |
5 | 8 | 0.16 | 165 | 15.30 | 288 | 727 | 3.71 / 19.23 | 2 | 24 |
Average= | 3.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 30 | 15.25 | 438 | 200 | 0.20 / 11.96 | 2 | 5 |
2 | 7 | 1508.36 | 74 | 15.04 | 2201 | 2450 | 2.65 / 14.41 | 2 | 16 |
3 | 13 | 542.16 | 18 | 15.24 | 1023 | 281 | 2.93 / 14.69 | 2 | 20 |
4 | 13 | 35.60 | 18 | 15.34 | 343 | 95 | 3.03 / 14.79 | 2 | 16 |
5 | 8 | 0.00 | 165 | 15.30 | 287 | 725 | 3.75 / 15.51 | 2 | 25 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 29 | 15.26 | 416 | 184 | 0.18 / 8.17 | 2 | 6 |
2 | 10 | 1002.04 | 2 | 15.28 | 1648 | 50 | 0.23 / 8.22 | 2 | 12 |
3 | 7 | 1526.60 | 75 | 15.05 | 2219 | 2505 | 2.74 / 10.73 | 2 | 19 |
4 | 13 | 389.80 | 18 | 15.28 | 820 | 226 | 2.96 / 10.95 | 2 | 20 |
5 | 13 | 23.80 | 18 | 15.35 | 325 | 90 | 3.05 / 11.04 | 2 | 15 |
6 | 8 | 0.04 | 165 | 15.30 | 285 | 719 | 3.77 / 11.76 | 2 | 30 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 32 | 15.32 | 433 | 212 | 0.21 / 4.47 | 2 | 5 |
2 | 3 | 937.64 | -1 | 15.67 | 0 | 0 | 0.00 / 4.47 | 2 | 5 |
3 | 3 | 947.76 | -1 | 15.72 | 0 | 0 | 0.00 / 4.47 | 2 | 5 |
4 | 7 | 1526.92 | 74 | 15.05 | 2215 | 2467 | 2.68 / 6.94 | 2 | 16 |
5 | 13 | 435.44 | 18 | 15.27 | 880 | 242 | 2.92 / 7.18 | 2 | 20 |
6 | 13 | 22.80 | 18 | 15.36 | 323 | 89 | 3.01 / 7.27 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.31 | 284 | 717 | 3.73 / 7.99 | 2 | 21 |
Average= | 2.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 27 | 15.45 | 390 | 163 | 0.16 / 1.67 | 2 | 3 |
2 | 10 | 1021.48 | 2 | 15.35 | 1655 | 51 | 0.21 / 1.72 | 2 | 11 |
3 | 3 | 1026.12 | 1 | 15.38 | 1699 | 26 | 0.24 / 1.74 | 2 | 14 |
4 | 7 | 997.72 | 74 | 15.22 | 1572 | 1771 | 2.01 / 3.51 | 2 | 20 |
5 | 8 | -0.04 | 165 | 15.38 | 295 | 749 | 2.76 / 4.26 | 2 | 28 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 128.68 | 26 | 15.62 | 410 | 167 | 0.17 / 0.17 | 2 | 5 |
2 | 7 | 144.28 | 75 | 15.58 | 420 | 491 | 0.66 / 0.66 | 2 | 5 |
3 | 8 | 0.32 | 240 | 15.53 | 227 | 846 | 1.50 / 1.50 | 2 | 15 |
Average= | 1.50 (KJ/cycle) |