SIO Argo Site:
Pump Diagnostics Page   



Serial= 3161 WMO= 5906790

Return

←PreviousNext→

Cycle 76 GMT 14/12/2024 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 32 15.07 450 217 0.22 / 289.17 2 6
2 7 2003.08 38 14.68 2930 1634 1.85 / 290.80 2 10
3 13 1394.12 18 14.78 2185 581 2.43 / 291.38 2 11
4 13 911.56 18 14.88 1565 419 2.85 / 291.80 2 13
5 13 388.80 18 15.03 877 237 3.09 / 292.04 2 14
6 13 33.40 18 15.14 347 95 3.18 / 292.13 2 8
7 8 0.12 165 15.12 293 731 3.91 / 292.86 2 13
Average= 3.80
(KJ/cycle)

Cycle 75 GMT 4/12/2024 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 32 15.06 449 216 0.22 / 285.32 2 6
2 7 2013.60 38 14.68 2941 1641 1.86 / 286.96 2 10
3 13 1371.52 18 14.79 2162 576 2.43 / 287.54 2 10
4 13 839.00 18 14.89 1473 395 2.83 / 287.93 2 12
5 13 323.84 18 15.05 760 206 3.03 / 288.14 2 13
6 13 15.36 18 15.16 315 86 3.12 / 288.23 2 4
7 8 0.16 165 15.11 290 723 3.84 / 288.95 2 9
Average= 3.80
(KJ/cycle)

Cycle 74 GMT 25/11/2024 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 32 15.08 451 218 0.22 / 281.51 2 4
2 7 2010.00 38 14.68 2935 1637 1.85 / 283.15 2 9
3 13 1362.00 18 14.79 2143 571 2.43 / 283.72 2 10
4 13 914.16 18 14.89 1566 420 2.85 / 284.14 2 12
5 13 407.00 18 15.03 897 243 3.09 / 284.38 2 13
6 8 0.12 165 15.12 290 723 3.81 / 285.11 2 10
Average= 3.80
(KJ/cycle)

Cycle 73 GMT 15/11/2024 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 32 15.09 432 209 0.21 / 277.78 2 3
2 7 2004.76 38 14.70 2929 1636 1.84 / 279.42 2 9
3 13 1379.28 18 14.79 2166 577 2.42 / 280.00 2 10
4 13 805.84 18 14.92 1421 382 2.80 / 280.38 2 13
5 13 337.72 18 15.07 776 210 3.01 / 280.59 2 12
6 8 0.24 165 15.13 283 706 3.72 / 281.30 2 8
Average= 3.80
(KJ/cycle)

Cycle 72 GMT 5/11/2024 12:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 32 15.09 459 222 0.22 / 273.96 2 6
2 7 2004.44 38 14.69 2930 1636 1.86 / 275.60 2 12
3 13 1406.20 18 14.80 2209 588 2.45 / 276.19 2 11
4 13 957.64 18 14.87 1630 436 2.88 / 276.62 2 13
5 13 412.12 18 15.05 890 241 3.12 / 276.86 2 13
6 8 0.04 165 15.14 285 712 3.84 / 277.58 2 7
Average= 3.80
(KJ/cycle)

Cycle 71 GMT 26/10/2024 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 32 15.10 450 217 0.22 / 270.19 2 3
2 7 2007.68 38 14.69 2931 1636 1.85 / 271.83 2 10
3 13 1398.72 18 14.79 2194 584 2.44 / 272.42 2 12
4 13 870.20 18 14.91 1509 405 2.84 / 272.82 2 14
5 13 331.72 18 15.08 769 209 3.05 / 273.03 2 13
6 8 0.20 165 15.14 285 712 3.76 / 273.74 2 24
Average= 3.80
(KJ/cycle)

Cycle 70 GMT 16/10/2024 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 32 15.11 454 220 0.22 / 266.39 2 4
2 7 2004.40 39 14.70 2934 1682 1.90 / 268.08 2 7
3 13 1325.24 18 14.81 2112 563 2.46 / 268.64 2 9
4 13 891.32 18 14.90 1539 413 2.88 / 269.05 2 13
5 13 344.84 18 15.07 787 213 3.09 / 269.27 2 12
6 8 0.08 165 15.14 285 712 3.80 / 269.98 2 12
Average= 3.80
(KJ/cycle)

Cycle 69 GMT 7/10/2024 4: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.88 32 15.10 451 218 0.22 / 262.59 2 7
2 7 2009.72 38 14.69 2937 1639 1.86 / 264.23 2 8
3 13 1344.68 18 14.81 2125 566 2.42 / 264.80 2 10
4 13 904.40 18 14.90 1556 417 2.84 / 265.22 2 13
5 13 381.40 18 15.06 864 234 3.08 / 265.45 2 13
6 8 0.20 165 15.15 290 725 3.80 / 266.17 2 16
Average= 3.80
(KJ/cycle)

Cycle 68 GMT 27/ 9/2024 9: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 32 15.12 448 217 0.22 / 258.78 2 3
2 7 2008.88 39 14.69 2936 1682 1.90 / 260.46 2 8
3 13 1403.88 18 14.80 2195 585 2.48 / 261.05 2 9
4 13 853.04 18 14.94 1486 400 2.88 / 261.45 2 14
5 13 327.60 18 15.10 768 209 3.09 / 261.66 2 13
6 8 0.16 165 15.15 287 717 3.81 / 262.37 2 16
Average= 3.80
(KJ/cycle)

Cycle 67 GMT 17/ 9/2024 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 15.12 435 210 0.21 / 254.97 2 8
2 7 2005.56 38 14.70 2926 1634 1.84 / 256.61 2 9
3 13 1422.64 18 14.81 2226 593 2.44 / 257.20 2 11
4 13 843.56 18 14.94 1481 398 2.84 / 257.60 2 12
5 13 391.68 18 15.08 864 235 3.07 / 257.83 2 14
6 8 0.00 165 15.16 292 730 3.80 / 258.56 2 6
Average= 3.80
(KJ/cycle)

Cycle 66 GMT 7/ 9/2024 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 32 15.13 452 219 0.22 / 251.19 2 4
2 7 2010.04 38 14.70 2936 1640 1.86 / 252.83 2 12
3 13 1400.24 18 14.81 2197 586 2.44 / 253.42 2 13
4 13 854.04 18 14.93 1509 406 2.85 / 253.82 2 13
5 13 339.00 18 15.11 793 216 3.07 / 254.04 2 13
6 8 0.12 165 15.17 290 726 3.79 / 254.76 2 14
Average= 3.80
(KJ/cycle)

Cycle 65 GMT 29/ 8/2024 0: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 32 15.13 432 209 0.21 / 247.40 2 3
2 7 2003.84 39 14.72 2922 1677 1.89 / 249.08 2 8
3 13 1382.96 18 14.82 2172 579 2.47 / 249.66 2 10
4 13 807.48 18 14.96 1431 385 2.85 / 250.04 2 14
5 13 326.72 18 15.12 770 210 3.06 / 250.25 2 12
6 8 0.08 165 15.17 287 718 3.78 / 250.97 2 8
Average= 3.80
(KJ/cycle)

Cycle 64 GMT 19/ 8/2024 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 32 15.13 453 219 0.22 / 243.63 2 3
2 7 2008.44 38 14.71 2937 1642 1.86 / 245.28 2 7
3 13 1374.72 18 14.83 2167 578 2.44 / 245.85 2 12
4 13 845.36 18 14.95 1477 397 2.84 / 246.25 2 13
5 13 355.52 18 15.10 808 220 3.06 / 246.47 2 13
6 8 0.44 165 15.17 288 721 3.78 / 247.19 2 5
Average= 3.80
(KJ/cycle)

Cycle 63 GMT 9/ 8/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 32 15.14 431 209 0.21 / 239.86 2 5
2 7 2004.20 38 14.71 2935 1641 1.85 / 241.50 2 8
3 13 1386.96 18 14.83 2195 586 2.44 / 242.08 2 11
4 13 857.68 18 14.95 1502 404 2.84 / 242.49 2 14
5 13 348.92 18 15.12 802 218 3.06 / 242.71 2 12
6 8 0.08 165 15.18 283 709 3.77 / 243.41 2 17
Average= 3.80
(KJ/cycle)

Cycle 62 GMT 30/ 7/2024 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 32 15.14 453 219 0.22 / 236.15 2 4
2 7 2006.76 38 14.72 2937 1643 1.86 / 237.79 2 8
3 13 1354.00 18 14.85 2133 570 2.43 / 238.36 2 13
4 13 793.12 18 14.98 1407 379 2.81 / 238.74 2 13
5 13 306.64 18 15.14 739 201 3.01 / 238.94 2 12
6 8 0.08 165 15.19 283 709 3.72 / 239.65 2 18
Average= 3.80
(KJ/cycle)

Cycle 61 GMT 20/ 7/2024 19:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 32 15.16 445 216 0.22 / 232.27 2 6
2 7 2011.88 38 14.73 2942 1647 1.86 / 233.92 2 9
3 13 1388.36 18 14.85 2182 583 2.45 / 234.50 2 12
4 13 827.60 18 14.98 1470 396 2.84 / 234.90 2 14
5 13 348.48 18 15.15 803 219 3.06 / 235.12 2 13
6 13 24.20 18 15.22 328 90 3.15 / 235.21 2 11
7 8 0.32 165 15.19 287 719 3.87 / 235.93 2 9
Average= 3.81
(KJ/cycle)

Cycle 60 GMT 11/ 7/2024 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 15.14 434 210 0.21 / 228.54 2 3
2 7 2006.36 38 14.72 2940 1645 1.85 / 230.18 2 8
3 13 1314.12 18 14.86 2091 559 2.41 / 230.74 2 12
4 13 811.00 18 14.98 1437 387 2.80 / 231.13 2 14
5 13 328.32 18 15.14 772 210 3.01 / 231.34 2 12
6 8 -0.04 165 15.19 285 714 3.73 / 232.06 2 19
Average= 3.80
(KJ/cycle)

Cycle 59 GMT 1/ 7/2024 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 15.15 462 224 0.22 / 224.77 2 3
2 7 2006.88 38 14.72 2955 1653 1.88 / 226.43 2 10
3 13 1332.24 18 14.86 2114 565 2.44 / 226.99 2 15
4 13 849.92 18 14.98 1489 401 2.84 / 227.39 2 13
5 13 359.68 18 15.13 817 223 3.07 / 227.62 2 14
6 8 0.16 165 15.20 284 712 3.78 / 228.33 2 14
Average= 3.81
(KJ/cycle)

Cycle 58 GMT 21/ 6/2024 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 32 15.14 468 227 0.23 / 220.89 2 6
2 7 2011.72 38 14.72 2957 1654 1.88 / 222.55 2 9
3 13 1406.00 18 14.84 2218 592 2.47 / 223.14 2 12
4 13 906.80 18 14.96 1569 423 2.90 / 223.56 2 13
5 13 349.56 18 15.15 803 219 3.11 / 223.78 2 13
6 8 0.16 165 15.19 307 769 3.88 / 224.55 2 4
Average= 3.81
(KJ/cycle)

Cycle 57 GMT 11/ 6/2024 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 32 15.16 430 209 0.21 / 216.89 2 3
2 7 2004.96 38 14.74 2941 1647 1.86 / 218.54 2 8
3 13 1403.08 18 14.85 2207 590 2.45 / 219.13 2 12
4 13 962.04 18 14.94 1635 440 2.89 / 219.57 2 14
5 13 390.60 18 15.12 887 241 3.13 / 219.81 2 14
6 13 18.60 18 15.22 335 92 3.22 / 219.90 2 5
7 8 0.16 165 15.19 305 764 3.98 / 220.67 2 17
Average= 3.80
(KJ/cycle)

Cycle 56 GMT 1/ 6/2024 20:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 31 15.15 472 222 0.22 / 213.09 2 3
2 7 2004.32 38 14.74 2936 1645 1.87 / 214.73 2 7
3 13 1419.80 18 14.85 2225 595 2.46 / 215.33 2 12
4 13 869.44 18 14.98 1518 409 2.87 / 215.74 2 14
5 13 361.60 18 15.14 823 224 3.09 / 215.96 2 13
6 8 0.12 165 15.21 288 723 3.82 / 216.68 2 15
Average= 3.80
(KJ/cycle)

Cycle 55 GMT 23/ 5/2024 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 31 15.17 427 201 0.20 / 209.24 2 3
2 7 2008.48 38 14.73 2944 1648 1.85 / 210.89 2 10
3 13 1315.72 18 14.87 2094 560 2.41 / 211.45 2 12
4 13 914.00 18 14.97 1585 427 2.84 / 211.87 2 14
5 13 350.88 18 15.14 807 220 3.06 / 212.09 2 14
6 8 0.08 165 15.19 308 772 3.83 / 212.87 2 6
Average= 3.80
(KJ/cycle)

Cycle 54 GMT 13/ 5/2024 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.16 427 201 0.20 / 205.50 2 3
2 7 2005.36 38 14.74 2936 1645 1.85 / 207.15 2 10
3 13 1368.56 18 14.88 2168 581 2.43 / 207.73 2 11
4 13 816.28 18 15.01 1446 391 2.82 / 208.12 2 13
5 13 295.88 18 15.17 728 199 3.02 / 208.32 2 13
6 8 0.16 165 15.22 287 721 3.74 / 209.04 2 5
Average= 3.80
(KJ/cycle)

Cycle 53 GMT 3/ 5/2024 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 31 15.17 446 210 0.21 / 201.63 2 3
2 7 2008.88 38 14.76 2938 1648 1.86 / 203.28 2 7
3 13 1365.80 18 14.87 2161 578 2.44 / 203.86 2 13
4 13 876.60 18 14.99 1528 412 2.85 / 204.27 2 14
5 13 346.24 18 15.15 803 219 3.07 / 204.49 2 13
6 13 51.48 18 15.23 373 102 3.17 / 204.59 2 17
7 8 0.04 165 15.20 284 712 3.88 / 205.30 2 8
Average= 3.80
(KJ/cycle)

Cycle 52 GMT 23/ 4/2024 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 31 15.16 427 201 0.20 / 197.75 2 3
2 7 2009.56 38 14.74 2936 1645 1.85 / 199.39 2 7
3 13 1377.92 18 14.87 2173 582 2.43 / 199.97 2 10
4 13 844.76 18 15.00 1484 401 2.83 / 200.37 2 13
5 13 354.04 18 15.15 814 222 3.05 / 200.59 2 14
6 13 54.68 18 15.23 375 103 3.15 / 200.70 2 11
7 8 0.00 165 15.21 288 723 3.88 / 201.42 2 19
Average= 3.80
(KJ/cycle)

Cycle 51 GMT 13/ 4/2024 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 15.16 424 199 0.20 / 193.87 2 6
2 7 2010.96 38 14.75 2941 1648 1.85 / 195.52 2 8
3 13 1343.36 18 14.89 2133 572 2.42 / 196.09 2 10
4 13 824.40 18 15.02 1458 394 2.81 / 196.49 2 13
5 13 385.24 18 15.14 871 237 3.05 / 196.73 2 13
6 13 40.96 18 15.24 362 99 3.15 / 196.82 2 14
7 8 0.24 165 15.21 287 720 3.87 / 197.54 2 7
Average= 3.80
(KJ/cycle)

Cycle 50 GMT 4/ 4/2024 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 15.16 430 202 0.20 / 190.05 2 3
2 7 2007.28 38 14.75 2944 1650 1.85 / 191.70 2 9
3 13 1295.68 18 14.91 2076 557 2.41 / 192.26 2 13
4 13 823.48 18 15.03 1452 393 2.80 / 192.65 2 13
5 13 296.40 18 15.19 732 200 3.00 / 192.85 2 12
6 13 54.84 18 15.25 379 104 3.11 / 192.95 2 10
7 8 0.12 165 15.22 287 721 3.83 / 193.67 2 9
Average= 3.80
(KJ/cycle)

Cycle 49 GMT 25/ 3/2024 6:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 31 15.16 431 203 0.20 / 186.18 2 3
2 7 2011.64 38 14.74 2939 1646 1.85 / 187.82 2 9
3 13 1365.20 18 14.87 2157 577 2.43 / 188.40 2 11
4 13 883.28 18 14.99 1529 413 2.84 / 188.81 2 13
5 13 331.56 18 15.16 785 214 3.05 / 189.03 2 13
6 13 34.88 18 15.24 348 95 3.15 / 189.12 2 7
7 8 0.20 165 15.21 288 723 3.87 / 189.85 2 8
Average= 3.80
(KJ/cycle)

Cycle 48 GMT 15/ 3/2024 11:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 15.17 427 201 0.20 / 182.31 2 4
2 7 2010.76 38 14.75 2943 1650 1.85 / 183.96 2 11
3 13 1354.28 18 14.89 2146 575 2.43 / 184.53 2 12
4 13 829.28 18 15.02 1461 395 2.82 / 184.93 2 14
5 13 338.12 18 15.17 806 220 3.04 / 185.15 2 13
6 13 40.84 18 15.24 359 98 3.14 / 185.25 2 7
7 8 0.08 165 15.21 290 728 3.87 / 185.98 2 18
Average= 3.80
(KJ/cycle)

Cycle 47 GMT 5/ 3/2024 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 31 15.18 420 198 0.20 / 178.45 2 8
2 7 2011.48 38 14.74 2941 1647 1.84 / 180.10 2 8
3 13 1367.52 18 14.88 2164 580 2.42 / 180.68 2 11
4 13 843.20 18 15.00 1482 400 2.82 / 181.08 2 14
5 13 345.32 18 15.16 796 217 3.04 / 181.30 2 13
6 13 44.28 18 15.23 364 100 3.14 / 181.40 2 17
7 8 0.12 165 15.21 283 710 3.85 / 182.11 2 10
Average= 3.79
(KJ/cycle)

Cycle 46 GMT 24/ 2/2024 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.44 31 15.18 450 212 0.21 / 174.63 2 3
2 7 2003.24 38 14.75 2933 1644 1.86 / 176.28 2 9
3 13 1370.36 18 14.88 2165 580 2.44 / 176.86 2 9
4 13 829.04 18 15.02 1454 393 2.83 / 177.25 2 12
5 13 303.96 18 15.18 749 205 3.03 / 177.46 2 12
6 13 32.56 18 15.25 342 94 3.13 / 177.55 2 11
7 8 0.20 165 15.22 282 708 3.84 / 178.26 2 17
Average= 3.79
(KJ/cycle)

Cycle 45 GMT 15/ 2/2024 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 31 15.19 425 200 0.20 / 170.72 2 5
2 7 2005.12 38 14.78 2942 1652 1.85 / 172.38 2 11
3 13 1415.96 18 14.89 2224 596 2.45 / 172.97 2 12
4 13 881.60 18 15.01 1534 414 2.86 / 173.39 2 14
5 13 340.44 18 15.18 795 217 3.08 / 173.60 2 13
6 13 42.04 18 15.27 357 98 3.18 / 173.70 2 7
7 8 0.12 165 15.22 287 721 3.90 / 174.42 2 4
Average= 3.79
(KJ/cycle)

Cycle 44 GMT 5/ 2/2024 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 15.20 426 201 0.20 / 166.85 2 4
2 7 2010.72 38 14.76 2939 1648 1.85 / 168.50 2 7
3 13 1349.84 18 14.91 2145 576 2.42 / 169.07 2 12
4 13 877.32 18 15.00 1524 411 2.84 / 169.49 2 14
5 13 343.92 18 15.18 795 217 3.05 / 169.70 2 13
6 13 41.24 18 15.26 358 98 3.15 / 169.80 2 16
7 8 0.08 165 15.23 287 721 3.87 / 170.52 2 4
Average= 3.79
(KJ/cycle)

Cycle 43 GMT 26/ 1/2024 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 31 15.18 443 208 0.21 / 162.98 2 4
2 7 2005.04 38 14.76 2941 1650 1.86 / 164.63 2 8
3 13 1361.00 18 14.90 2160 579 2.44 / 165.21 2 9
4 13 825.56 18 15.03 1463 396 2.83 / 165.61 2 14
5 13 338.44 18 15.18 790 216 3.05 / 165.82 2 13
6 13 37.36 18 15.27 356 98 3.15 / 165.92 2 8
7 8 0.04 165 15.24 290 729 3.88 / 166.65 2 10
Average= 3.79
(KJ/cycle)

Cycle 42 GMT 16/ 1/2024 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 15.21 455 215 0.21 / 159.18 2 3
2 7 2003.76 38 14.77 2943 1652 1.87 / 160.83 2 10
3 13 1235.24 18 14.95 1988 535 2.40 / 161.36 2 11
4 13 776.00 18 15.06 1388 376 2.78 / 161.74 2 15
5 13 327.20 18 15.19 771 211 2.99 / 161.95 2 14
6 13 35.64 18 15.26 350 96 3.08 / 162.05 2 6
7 8 0.12 165 15.24 289 727 3.81 / 162.77 2 13
Average= 3.79
(KJ/cycle)

Cycle 41 GMT 6/ 1/2024 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 31 15.21 456 215 0.22 / 155.30 2 5
2 7 2004.60 38 14.77 2938 1649 1.86 / 156.95 2 11
3 13 1398.52 18 14.91 2207 592 2.46 / 157.54 2 9
4 13 814.32 18 15.04 1445 391 2.85 / 157.93 2 14
5 13 327.96 18 15.21 773 212 3.06 / 158.14 2 13
6 13 18.48 18 15.27 320 88 3.15 / 158.23 2 4
7 8 0.00 165 15.24 291 732 3.88 / 158.96 2 6
Average= 3.78
(KJ/cycle)

Cycle 40 GMT 28/12/2023 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 31 15.21 424 200 0.20 / 151.33 2 4
2 7 2005.36 39 14.77 2939 1693 1.89 / 153.02 2 9
3 13 1398.64 18 14.91 2200 590 2.48 / 153.61 2 10
4 13 899.56 18 15.04 1558 422 2.91 / 154.04 2 14
5 13 338.16 18 15.19 789 216 3.12 / 154.25 2 13
6 13 41.44 18 15.29 361 99 3.22 / 154.35 2 16
7 8 0.04 165 15.25 291 732 3.95 / 155.08 2 6
Average= 3.78
(KJ/cycle)

Cycle 39 GMT 18/12/2023 8: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 31 15.21 439 207 0.21 / 147.36 2 4
2 7 2003.44 38 14.79 2943 1654 1.86 / 149.02 2 10
3 13 1440.40 18 14.90 2261 606 2.47 / 149.62 2 9
4 13 990.56 18 15.00 1680 454 2.92 / 150.08 2 12
5 13 376.44 18 15.18 847 231 3.15 / 150.31 2 14
6 13 36.68 18 15.28 350 96 3.25 / 150.40 2 8
7 8 0.08 165 15.25 289 727 3.98 / 151.13 2 13
Average= 3.78
(KJ/cycle)

Cycle 38 GMT 8/12/2023 12:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 31 15.21 457 215 0.22 / 143.58 2 5
2 7 2006.08 38 14.77 2947 1654 1.87 / 145.23 2 7
3 13 1351.48 18 14.92 2146 576 2.45 / 145.81 2 12
4 13 825.40 18 15.05 1460 396 2.84 / 146.21 2 14
5 13 382.40 18 15.18 855 234 3.07 / 146.44 2 13
6 8 0.04 165 15.26 284 715 3.79 / 147.16 2 8
Average= 3.77
(KJ/cycle)

Cycle 37 GMT 28/11/2023 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 15.20 432 204 0.20 / 139.66 2 3
2 7 2003.64 38 14.79 2943 1654 1.86 / 141.31 2 6
3 13 1333.88 18 14.94 2126 572 2.43 / 141.89 2 13
4 13 903.12 18 15.04 1562 423 2.85 / 142.31 2 14
5 13 381.16 18 15.18 856 234 3.09 / 142.54 2 14
6 13 28.16 18 15.28 335 92 3.18 / 142.64 2 4
7 8 0.12 165 15.25 290 730 3.91 / 143.37 2 11
Average= 3.77
(KJ/cycle)

Cycle 36 GMT 18/11/2023 22:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 31 15.24 463 219 0.22 / 135.75 2 3
2 7 2003.80 38 14.76 2943 1651 1.87 / 137.40 2 7
3 13 1445.72 18 14.88 2264 606 2.48 / 138.01 2 10
4 13 862.36 18 15.03 1510 409 2.88 / 138.42 2 14
5 13 319.96 18 15.20 763 209 3.09 / 138.62 2 13
6 13 32.72 18 15.28 346 95 3.19 / 138.72 2 16
7 8 0.00 165 15.25 293 737 3.93 / 139.46 2 3
Average= 3.77
(KJ/cycle)

Cycle 35 GMT 9/11/2023 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 31 15.22 460 217 0.22 / 132.31 2 4
2 7 1505.16 38 14.97 2315 1317 1.53 / 133.62 2 10
3 13 1345.16 18 14.99 2131 575 2.11 / 134.20 2 12
4 13 869.12 18 15.09 1513 411 2.52 / 134.61 2 14
5 13 261.04 18 15.26 675 185 2.71 / 134.79 2 12
6 8 0.12 165 15.30 292 737 3.44 / 135.53 2 15
Average= 3.76
(KJ/cycle)

Cycle 34 GMT 30/10/2023 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 31 15.23 430 203 0.20 / 128.48 2 3
2 7 2010.88 38 14.79 2953 1660 1.86 / 130.14 2 9
3 13 1437.28 18 14.91 2247 603 2.47 / 130.75 2 10
4 13 787.72 18 15.07 1416 384 2.85 / 131.13 2 13
5 13 353.28 18 15.20 820 224 3.07 / 131.35 2 13
6 8 0.12 165 15.26 292 735 3.81 / 132.09 2 11
Average= 3.77
(KJ/cycle)

Cycle 33 GMT 20/10/2023 11:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 31 15.23 427 202 0.20 / 124.70 2 4
2 7 2009.68 38 14.80 2946 1657 1.86 / 126.36 2 7
3 13 1376.08 18 14.94 2178 586 2.44 / 126.95 2 11
4 13 830.08 18 15.07 1464 397 2.84 / 127.34 2 14
5 13 334.36 18 15.22 782 214 3.06 / 127.56 2 14
6 8 0.12 165 15.27 287 723 3.78 / 128.28 2 6
Average= 3.77
(KJ/cycle)

Cycle 32 GMT 10/10/2023 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 31 15.23 450 212 0.21 / 120.90 2 5
2 7 2009.40 39 14.80 2950 1703 1.92 / 122.60 2 10
3 13 1345.00 18 14.95 2128 573 2.49 / 123.17 2 13
4 13 811.64 18 15.08 1440 391 2.88 / 123.57 2 13
5 13 314.60 18 15.22 758 208 3.09 / 123.77 2 13
6 8 0.08 165 15.27 289 728 3.81 / 124.50 2 18
Average= 3.77
(KJ/cycle)

Cycle 31 GMT 30/ 9/2023 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 31 15.24 458 216 0.22 / 117.11 2 4
2 7 2007.92 38 14.81 2948 1659 1.88 / 118.77 2 7
3 13 1348.08 18 14.95 2133 574 2.45 / 119.34 2 12
4 13 811.96 18 15.08 1439 391 2.84 / 119.73 2 14
5 13 357.24 18 15.21 820 224 3.06 / 119.96 2 14
6 8 0.24 165 15.27 290 731 3.80 / 120.69 2 18
Average= 3.77
(KJ/cycle)

Cycle 30 GMT 21/ 9/2023 2:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 31 15.23 453 214 0.21 / 113.29 2 5
2 7 2006.96 39 14.81 2944 1700 1.91 / 114.99 2 7
3 13 1346.88 18 14.95 2135 575 2.49 / 115.56 2 12
4 13 813.68 18 15.08 1441 391 2.88 / 115.96 2 15
5 13 326.28 18 15.23 773 212 3.09 / 116.17 2 13
6 8 0.04 165 15.28 287 724 3.82 / 116.89 2 11
Average= 3.77
(KJ/cycle)

Cycle 29 GMT 11/ 9/2023 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 31 15.25 452 214 0.21 / 109.52 2 4
2 7 2003.56 38 14.80 2936 1651 1.86 / 111.17 2 8
3 13 1356.16 18 14.95 2152 579 2.44 / 111.75 2 11
4 13 789.64 18 15.08 1410 383 2.83 / 112.13 2 14
5 13 359.80 18 15.21 818 224 3.05 / 112.35 2 13
6 8 0.12 165 15.28 287 724 3.77 / 113.08 2 19
Average= 3.77
(KJ/cycle)

Cycle 28 GMT 1/ 9/2023 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.68 31 15.26 452 214 0.21 / 105.75 2 4
2 7 2005.20 38 14.81 2944 1657 1.87 / 107.41 2 6
3 13 1264.08 18 14.97 2026 546 2.42 / 107.96 2 12
4 13 868.52 18 15.06 1517 411 2.83 / 108.37 2 14
5 13 347.40 18 15.22 800 219 3.05 / 108.59 2 14
6 8 0.04 165 15.29 284 716 3.76 / 109.30 2 9
Average= 3.77
(KJ/cycle)

Cycle 27 GMT 22/ 8/2023 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 31 15.25 459 217 0.22 / 102.41 2 5
2 7 1470.20 38 15.00 2276 1297 1.51 / 103.71 2 11
3 13 1300.68 18 15.03 2076 562 2.08 / 104.27 2 11
4 13 744.72 18 15.16 1350 368 2.44 / 104.64 2 14
5 13 258.04 18 15.29 661 182 2.63 / 104.82 2 12
6 8 0.00 165 15.31 285 720 3.35 / 105.54 2 11
Average= 3.77
(KJ/cycle)

Cycle 26 GMT 12/ 8/2023 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 31 15.24 430 203 0.20 / 98.61 2 4
2 7 2006.68 38 14.83 2945 1660 1.86 / 100.27 2 10
3 13 1278.20 18 14.99 2060 556 2.42 / 100.82 2 13
4 13 887.52 18 15.08 1543 419 2.84 / 101.24 2 14
5 13 354.80 18 15.24 812 223 3.06 / 101.47 2 12
6 8 0.24 165 15.30 288 727 3.79 / 102.19 2 17
Average= 3.78
(KJ/cycle)

Cycle 25 GMT 3/ 8/2023 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 31 15.25 441 208 0.21 / 94.82 2 3
2 7 2010.56 38 14.82 2957 1665 1.87 / 96.48 2 7
3 13 1377.48 18 14.96 2194 591 2.46 / 97.07 2 13
4 13 777.92 18 15.11 1402 381 2.85 / 97.45 2 13
5 13 335.36 18 15.24 791 217 3.06 / 97.67 2 13
6 8 0.16 165 15.29 291 734 3.80 / 98.40 2 5
Average= 3.78
(KJ/cycle)

Cycle 24 GMT 24/ 7/2023 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 31 15.25 450 213 0.21 / 90.99 2 3
2 7 2006.16 38 14.84 2951 1664 1.88 / 92.65 2 11
3 13 1399.24 18 14.97 2208 595 2.47 / 93.24 2 12
4 13 832.44 18 15.11 1469 400 2.87 / 93.64 2 14
5 13 337.88 18 15.26 790 217 3.09 / 93.86 2 13
6 8 0.20 165 15.30 296 747 3.84 / 94.61 2 7
Average= 3.78
(KJ/cycle)

Cycle 23 GMT 14/ 7/2023 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 31 15.27 428 203 0.20 / 87.14 2 3
2 7 2003.60 38 14.83 2944 1659 1.86 / 88.80 2 7
3 13 1303.12 18 14.98 2082 561 2.42 / 89.36 2 11
4 13 820.32 18 15.10 1451 394 2.82 / 89.75 2 13
5 13 314.68 18 15.26 757 208 3.03 / 89.96 2 13
6 13 12.56 18 15.33 314 87 3.11 / 90.05 2 15
7 8 0.00 165 15.29 288 727 3.84 / 90.77 2 17
Average= 3.78
(KJ/cycle)

Cycle 22 GMT 4/ 7/2023 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 31 15.25 454 215 0.21 / 83.39 2 4
2 7 2003.24 38 14.85 2940 1659 1.87 / 85.05 2 7
3 13 1285.92 18 15.01 2066 558 2.43 / 85.60 2 12
4 13 778.92 18 15.13 1396 380 2.81 / 85.98 2 14
5 13 367.72 18 15.23 833 228 3.04 / 86.21 2 14
6 8 0.20 165 15.30 286 722 3.76 / 86.93 2 14
Average= 3.78
(KJ/cycle)

Cycle 21 GMT 24/ 6/2023 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 31 15.27 421 199 0.20 / 79.49 2 3
2 7 2011.76 38 14.85 2952 1666 1.87 / 81.15 2 8
3 13 1352.04 18 15.00 2151 581 2.45 / 81.73 2 10
4 13 865.88 18 15.11 1527 415 2.86 / 82.15 2 13
5 13 318.08 18 15.26 763 210 3.07 / 82.36 2 12
6 13 15.64 18 15.34 318 88 3.16 / 82.45 2 4
7 8 0.04 165 15.31 287 725 3.88 / 83.17 2 19
Average= 3.78
(KJ/cycle)

Cycle 20 GMT 15/ 6/2023 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 31 15.26 428 202 0.20 / 75.55 2 3
2 7 2004.96 38 14.86 2944 1662 1.86 / 77.21 2 11
3 13 1516.76 18 14.96 2359 635 2.50 / 77.85 2 11
4 13 859.04 18 15.12 1508 410 2.91 / 78.26 2 13
5 13 359.36 18 15.25 816 224 3.13 / 78.48 2 13
6 13 55.28 18 15.34 369 102 3.24 / 78.59 2 11
7 8 0.16 165 15.31 278 702 3.94 / 79.29 2 14
Average= 3.78
(KJ/cycle)

Cycle 19 GMT 5/ 6/2023 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.27 428 203 0.20 / 71.66 2 6
2 7 2003.48 38 14.86 2952 1667 1.87 / 73.33 2 8
3 13 1318.44 18 15.00 2116 571 2.44 / 73.90 2 10
4 13 794.00 18 15.12 1420 386 2.83 / 74.29 2 14
5 13 344.44 18 15.26 800 220 3.05 / 74.51 2 13
6 13 77.36 18 15.32 407 112 3.16 / 74.62 2 8
7 8 0.08 165 15.31 288 728 3.89 / 75.35 2 5
Average= 3.77
(KJ/cycle)

Cycle 18 GMT 26/ 5/2023 10:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.27 431 204 0.20 / 67.75 2 5
2 7 2003.40 38 14.87 2945 1664 1.87 / 69.42 2 9
3 13 1393.84 18 15.00 2204 595 2.46 / 70.01 2 11
4 13 830.40 18 15.12 1472 401 2.86 / 70.41 2 14
5 13 330.80 18 15.27 777 214 3.08 / 70.63 2 13
6 13 37.92 18 15.34 359 99 3.18 / 70.72 2 15
7 8 0.08 165 15.32 292 738 3.91 / 71.46 2 9
Average= 3.76
(KJ/cycle)

Cycle 17 GMT 16/ 5/2023 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.27 421 199 0.20 / 63.83 2 3
2 7 2010.20 38 14.88 2946 1666 1.87 / 65.49 2 9
3 13 1490.84 18 14.98 2323 626 2.49 / 66.12 2 12
4 13 838.76 18 15.13 1481 403 2.89 / 66.52 2 13
5 13 308.36 18 15.27 750 206 3.10 / 66.73 2 12
6 13 59.56 18 15.34 378 104 3.21 / 66.83 2 17
7 8 0.08 165 15.32 282 713 3.92 / 67.55 2 6
Average= 3.75
(KJ/cycle)

Cycle 16 GMT 6/ 5/2023 19:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 30 15.28 443 203 0.20 / 59.94 2 4
2 7 2006.44 38 14.88 2951 1669 1.87 / 61.60 2 9
3 13 1359.68 18 15.01 2166 585 2.46 / 62.19 2 12
4 13 819.96 18 15.13 1456 397 2.85 / 62.59 2 12
5 13 366.64 18 15.26 831 228 3.08 / 62.81 2 15
6 13 60.32 18 15.35 382 106 3.19 / 62.92 2 16
7 8 0.16 165 15.32 281 710 3.90 / 63.63 2 14
Average= 3.74
(KJ/cycle)

Cycle 15 GMT 27/ 4/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 15.29 419 192 0.19 / 56.09 2 3
2 3 982.32 -1 15.63 0 0 0.00 / 56.09 2 3
3 3 1027.08 1 15.31 1794 27 0.22 / 56.12 2 7
4 7 2008.00 38 14.88 2949 1667 1.89 / 57.79 2 10
5 13 1309.80 18 15.02 2087 564 2.45 / 58.35 2 12
6 13 787.84 18 15.14 1410 384 2.84 / 58.73 2 13
7 13 272.76 18 15.29 699 192 3.03 / 58.93 2 12
8 13 39.44 18 15.36 352 97 3.13 / 59.02 2 9
9 8 0.00 165 15.32 280 708 3.83 / 59.73 2 12
Average= 3.73
(KJ/cycle)

Cycle 14 GMT 17/ 4/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 15.28 423 194 0.19 / 52.23 2 3
2 7 2007.08 38 14.88 2947 1666 1.86 / 53.90 2 6
3 13 1307.32 18 15.04 2089 566 2.43 / 54.47 2 13
4 13 771.52 18 15.17 1393 380 2.81 / 54.85 2 14
5 13 373.68 18 15.27 845 232 3.04 / 55.08 2 13
6 13 48.52 18 15.36 368 102 3.14 / 55.18 2 5
7 8 0.00 165 15.33 284 718 3.86 / 55.90 2 13
Average= 3.73
(KJ/cycle)

Cycle 13 GMT 7/ 4/2023 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 15.29 420 193 0.19 / 48.38 2 3
2 7 2008.96 38 14.90 2944 1667 1.86 / 50.05 2 6
3 13 1327.16 18 15.05 2098 568 2.43 / 50.62 2 11
4 13 805.44 18 15.17 1425 389 2.82 / 51.01 2 13
5 13 356.84 18 15.28 806 222 3.04 / 51.23 2 14
6 13 45.28 18 15.35 357 99 3.14 / 51.33 2 13
7 8 0.16 165 15.32 282 713 3.85 / 52.04 2 19
Average= 3.72
(KJ/cycle)

Cycle 12 GMT 28/ 3/2023 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 30 15.30 426 196 0.20 / 44.61 2 3
2 7 2004.80 38 14.89 2942 1665 1.86 / 46.27 2 7
3 13 1288.32 18 15.05 2051 556 2.42 / 46.83 2 12
4 13 764.40 18 15.17 1369 374 2.79 / 47.20 2 14
5 13 322.80 18 15.29 757 208 3.00 / 47.41 2 14
6 13 36.52 18 15.36 334 92 3.09 / 47.50 2 6
7 8 -0.04 165 15.34 272 688 3.78 / 48.19 2 9
Average= 3.71
(KJ/cycle)

Cycle 11 GMT 18/ 3/2023 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 30 15.30 428 196 0.20 / 40.82 2 4
2 7 2005.24 38 14.90 2946 1668 1.86 / 42.49 2 7
3 13 1322.00 18 15.03 2088 565 2.43 / 43.06 2 12
4 13 748.04 18 15.17 1343 367 2.80 / 43.42 2 14
5 13 339.40 18 15.29 774 213 3.01 / 43.64 2 14
6 13 34.20 18 15.37 328 91 3.10 / 43.73 2 5
7 8 0.12 165 15.34 270 683 3.78 / 44.41 2 6
Average= 3.70
(KJ/cycle)

Cycle 10 GMT 9/ 3/2023 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 30 15.30 421 193 0.19 / 37.03 2 3
2 7 2003.92 38 14.90 2939 1664 1.86 / 38.70 2 8
3 13 1398.16 18 15.02 2199 595 2.45 / 39.29 2 11
4 13 722.16 18 15.17 1315 359 2.81 / 39.65 2 14
5 13 336.04 18 15.28 766 211 3.02 / 39.86 2 13
6 13 16.72 18 15.37 296 82 3.10 / 39.94 2 9
7 8 -0.04 165 15.34 270 683 3.79 / 40.63 2 11
Average= 3.69
(KJ/cycle)

Cycle 9 GMT 27/ 2/2023 4:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 15.30 414 190 0.19 / 33.24 2 3
2 7 2004.40 38 14.90 2933 1661 1.85 / 34.90 2 7
3 13 1247.04 18 15.06 1998 542 2.39 / 35.44 2 12
4 13 819.84 18 15.15 1443 394 2.79 / 35.84 2 13
5 13 365.96 18 15.28 815 224 3.01 / 36.06 2 13
6 13 15.68 18 15.36 301 83 3.09 / 36.15 2 4
7 8 -0.04 165 15.33 275 696 3.79 / 36.84 2 9
Average= 3.68
(KJ/cycle)

Cycle 8 GMT 17/ 2/2023 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 30 15.30 428 196 0.20 / 29.44 2 3
2 7 2006.72 38 14.91 2942 1667 1.86 / 31.10 2 7
3 13 1252.00 18 15.06 2005 544 2.41 / 31.65 2 12
4 13 810.44 18 15.16 1428 390 2.80 / 32.04 2 14
5 13 384.52 18 15.27 844 232 3.03 / 32.27 2 14
6 13 23.36 18 15.37 315 87 3.12 / 32.36 2 13
7 8 0.08 165 15.34 275 696 3.81 / 33.05 2 7
Average= 3.67
(KJ/cycle)

Cycle 7 GMT 7/ 2/2023 14:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.84 30 15.30 434 199 0.20 / 25.64 2 3
2 3 1036.84 1 15.30 1781 27 0.23 / 25.67 2 7
3 7 2008.44 38 14.91 2940 1666 1.89 / 27.33 2 8
4 13 1296.08 18 15.06 2059 558 2.45 / 27.89 2 12
5 13 757.40 18 15.18 1358 371 2.82 / 28.26 2 13
6 13 315.20 18 15.31 744 205 3.03 / 28.47 2 12
7 13 23.80 18 15.37 311 86 3.11 / 28.55 2 8
8 8 0.00 165 15.34 271 686 3.80 / 29.24 2 9
Average= 3.66
(KJ/cycle)

Cycle 6 GMT 28/ 1/2023 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 29 15.31 426 189 0.19 / 21.16 2 3
2 10 1023.24 2 15.31 1746 53 0.24 / 21.21 2 4
3 7 2003.36 74 14.81 2919 3199 3.44 / 24.41 2 9
4 13 412.92 18 15.30 886 244 3.69 / 24.65 2 13
5 13 72.84 18 15.38 383 106 3.79 / 24.76 2 9
6 8 0.08 165 15.35 270 684 4.48 / 25.44 2 15
Average= 3.63
(KJ/cycle)

Cycle 5 GMT 18/ 1/2023 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 29 15.34 420 187 0.19 / 16.70 2 3
2 7 2008.20 74 14.81 2922 3202 3.39 / 19.90 2 9
3 13 520.60 18 15.25 1039 285 3.67 / 20.18 2 14
4 13 53.24 18 15.38 355 98 3.77 / 20.28 2 8
5 8 0.08 165 15.35 270 684 4.46 / 20.97 2 11
Average= 3.49
(KJ/cycle)

Cycle 4 GMT 9/ 1/2023 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 37 15.30 408 231 0.23 / 12.98 2 3
2 3 723.52 -5 15.68 0 0 0.00 / 12.98 2 3
3 3 849.68 -3 15.70 0 0 0.00 / 12.98 2 3
4 7 1509.64 74 15.01 2300 2555 2.79 / 15.54 2 9
5 13 292.60 18 15.35 703 194 2.98 / 15.73 2 11
6 13 31.88 18 15.40 324 90 3.07 / 15.82 2 10
7 8 0.00 165 15.36 272 689 3.76 / 16.51 2 15
Average= 3.30
(KJ/cycle)

Cycle 3 GMT 8/ 1/2023 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.32 422 181 0.18 / 8.89 2 3
2 10 1021.92 4 15.30 1714 105 0.29 / 9.00 2 4
3 10 1074.48 3 15.27 1807 83 0.37 / 9.08 2 4
4 3 1125.44 4 15.27 1913 117 0.49 / 9.20 2 8
5 3 1018.96 1 15.35 1782 27 0.51 / 9.22 2 8
6 7 1509.12 74 15.00 2300 2553 3.07 / 11.78 2 8
7 13 295.68 18 15.35 707 195 3.26 / 11.97 2 12
8 13 31.32 18 15.38 324 90 3.35 / 12.06 2 5
9 8 0.04 165 15.36 272 689 4.04 / 12.75 2 18
Average= 3.19
(KJ/cycle)

Cycle 2 GMT 7/ 1/2023 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 31 15.33 418 199 0.20 / 5.17 2 4
2 3 870.04 -2 15.70 0 0 0.00 / 5.17 2 4
3 3 946.68 -1 15.74 0 0 0.00 / 5.17 2 4
4 7 1521.16 74 15.01 2312 2568 2.77 / 7.74 2 10
5 13 295.48 18 15.34 706 195 2.96 / 7.93 2 12
6 13 26.36 18 15.39 315 87 3.05 / 8.02 2 9
7 8 0.08 165 15.36 272 689 3.74 / 8.71 2 9
Average= 2.90
(KJ/cycle)

Cycle 1 GMT 6/ 1/2023 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 26 15.52 382 154 0.15 / 1.59 3 3
2 10 1070.68 5 15.35 1794 138 0.29 / 1.73 2 3
3 10 1150.84 5 15.35 1890 145 0.44 / 1.87 2 3
4 3 1151.88 4 15.31 1909 117 0.55 / 1.99 2 4
5 3 1308.36 9 15.21 2163 296 0.85 / 2.29 2 5
6 7 1098.40 74 15.12 1768 1978 2.83 / 4.26 2 10
7 8 0.16 165 15.38 279 708 3.54 / 4.97 2 16
Average= 2.49
(KJ/cycle)

Cycle 0 GMT 5/ 1/2023 17:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 96.72 26 15.65 368 150 0.15 / 0.15 3 3
2 7 112.48 74 15.62 385 445 0.59 / 0.59 3 3
3 8 0.36 240 15.59 225 842 1.44 / 1.44 3 15
Average= 1.44
(KJ/cycle)