SIO Argo Site:
Pump Diagnostics Page   



Serial= 3160 WMO= 5906789

Return

←PreviousNext→

Cycle 69 GMT 7/10/2024 1: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 31 15.09 449 210 0.21 / 267.47 2 3
2 7 2010.72 39 14.72 2963 1701 1.91 / 269.17 2 3
3 13 1373.56 18 14.82 2182 582 2.49 / 269.75 2 3
4 13 846.76 18 14.92 1499 403 2.90 / 270.15 2 3
5 13 436.32 18 15.04 951 257 3.15 / 270.41 2 3
6 8 0.08 165 15.11 293 730 3.88 / 271.14 2 3
Average= 3.87
(KJ/cycle)

Cycle 68 GMT 27/ 9/2024 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 31 15.08 458 214 0.21 / 263.60 3 3
2 7 2013.72 38 14.74 2977 1667 1.88 / 265.27 2 3
3 13 1423.20 18 14.81 2251 600 2.48 / 265.87 2 3
4 13 840.56 18 14.94 1497 403 2.88 / 266.27 2 3
5 13 402.84 18 15.06 901 244 3.13 / 266.52 2 3
6 8 0.08 165 15.13 296 739 3.87 / 267.26 2 6
Average= 3.87
(KJ/cycle)

Cycle 67 GMT 17/ 9/2024 10:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 15.09 444 208 0.21 / 259.76 2 3
2 7 2006.52 38 14.73 2964 1659 1.87 / 261.42 2 3
3 13 1386.64 18 14.81 2204 588 2.45 / 262.01 2 3
4 13 816.80 18 14.94 1466 394 2.85 / 262.40 2 3
5 13 425.84 18 15.05 933 253 3.10 / 262.66 2 3
6 8 0.08 165 15.13 294 734 3.84 / 263.39 2 3
Average= 3.87
(KJ/cycle)

Cycle 66 GMT 7/ 9/2024 15:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 15.09 440 206 0.21 / 255.90 2 3
2 7 2005.56 38 14.73 2970 1662 1.87 / 257.57 2 2
3 13 1403.12 18 14.81 2220 592 2.46 / 258.16 2 3
4 13 894.40 18 14.93 1568 421 2.88 / 258.58 2 3
5 13 395.08 18 15.06 886 240 3.12 / 258.82 2 3
6 8 0.16 165 15.13 295 736 3.86 / 259.56 2 7
Average= 3.87
(KJ/cycle)

Cycle 65 GMT 28/ 8/2024 20:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 31 15.09 450 211 0.21 / 252.13 2 3
2 7 2010.04 38 14.73 2963 1659 1.87 / 253.79 2 2
3 13 1329.52 18 14.83 2130 569 2.44 / 254.35 2 2
4 13 791.76 18 14.95 1429 385 2.82 / 254.74 2 3
5 13 356.36 18 15.08 834 226 3.05 / 254.97 2 3
6 8 0.12 165 15.13 293 731 3.78 / 255.70 2 4
Average= 3.87
(KJ/cycle)

Cycle 64 GMT 19/ 8/2024 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 31 15.10 443 207 0.21 / 248.30 3 3
2 7 2005.36 38 14.73 2955 1654 1.86 / 249.96 2 3
3 13 1425.60 18 14.82 2252 601 2.46 / 250.56 2 3
4 13 788.20 18 14.97 1425 384 2.85 / 250.94 2 3
5 13 405.24 18 15.07 902 245 3.09 / 251.19 2 3
6 8 0.20 165 15.14 293 732 3.82 / 251.92 2 8
Average= 3.88
(KJ/cycle)

Cycle 63 GMT 9/ 8/2024 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 31 15.10 436 204 0.20 / 244.54 3 3
2 7 2005.00 38 14.74 2966 1661 1.87 / 246.20 2 3
3 13 1284.24 18 14.87 2069 554 2.42 / 246.76 2 3
4 13 816.92 18 14.95 1457 392 2.81 / 247.15 2 3
5 13 343.16 18 15.08 817 222 3.03 / 247.37 2 3
6 8 0.16 165 15.14 290 724 3.76 / 248.09 2 6
Average= 3.88
(KJ/cycle)

Cycle 62 GMT 30/ 7/2024 10:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 31 15.10 448 210 0.21 / 240.69 3 3
2 7 2003.52 38 14.74 2962 1659 1.87 / 242.35 2 3
3 13 1368.28 18 14.84 2174 581 2.45 / 242.93 2 3
4 13 925.28 18 14.93 1603 431 2.88 / 243.36 2 3
5 13 374.00 18 15.08 858 233 3.11 / 243.60 2 3
6 8 0.04 165 15.14 296 739 3.85 / 244.34 2 7
Average= 3.88
(KJ/cycle)

Cycle 61 GMT 20/ 7/2024 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 31 15.11 451 211 0.21 / 236.77 2 3
2 7 2004.20 38 14.74 2951 1653 1.86 / 238.42 2 3
3 13 1491.44 18 14.82 2329 621 2.49 / 239.04 2 3
4 13 810.52 18 14.98 1448 390 2.88 / 239.43 2 3
5 13 378.72 18 15.09 867 235 3.11 / 239.67 2 3
6 13 19.92 18 15.18 327 89 3.20 / 239.76 2 3
7 8 0.20 165 15.15 291 727 3.93 / 240.48 2 4
Average= 3.88
(KJ/cycle)

Cycle 60 GMT 10/ 7/2024 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 31 15.10 439 205 0.21 / 232.95 2 3
2 7 2009.28 38 14.73 2964 1659 1.86 / 234.61 2 2
3 13 1395.48 18 14.85 2211 591 2.46 / 235.20 2 3
4 13 812.40 18 14.97 1451 391 2.85 / 235.59 2 3
5 13 370.40 18 15.09 851 231 3.08 / 235.82 2 3
6 8 0.04 165 15.15 295 737 3.82 / 236.56 2 9
Average= 3.88
(KJ/cycle)

Cycle 59 GMT 1/ 7/2024 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 31 15.10 456 213 0.21 / 229.04 3 3
2 7 2010.44 38 14.75 2964 1661 1.87 / 230.70 2 3
3 13 1363.76 18 14.85 2175 581 2.46 / 231.28 2 3
4 13 837.88 18 14.97 1486 400 2.86 / 231.68 2 3
5 13 355.48 18 15.11 829 225 3.08 / 231.91 2 3
6 13 57.24 18 15.18 376 103 3.18 / 232.01 2 3
7 8 0.12 165 15.15 292 730 3.91 / 232.74 2 6
Average= 3.88
(KJ/cycle)

Cycle 58 GMT 21/ 6/2024 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 31 15.12 438 205 0.21 / 225.17 3 3
2 7 2003.84 38 14.74 2954 1655 1.86 / 226.83 2 2
3 13 1284.72 18 14.87 2066 553 2.41 / 227.38 2 3
4 13 855.16 18 14.95 1505 405 2.82 / 227.79 2 3
5 13 359.80 18 15.10 837 227 3.05 / 228.01 2 3
6 13 20.76 18 15.19 324 89 3.13 / 228.10 2 4
7 8 0.20 165 15.15 290 725 3.86 / 228.83 2 4
Average= 3.88
(KJ/cycle)

Cycle 57 GMT 11/ 6/2024 10:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 15.11 438 205 0.21 / 221.28 2 3
2 7 2005.92 39 14.74 2966 1705 1.91 / 222.98 2 2
3 13 1412.40 18 14.84 2232 596 2.51 / 223.58 2 3
4 13 914.80 18 14.94 1585 426 2.93 / 224.00 2 3
5 13 394.28 18 15.09 884 240 3.17 / 224.24 2 3
6 8 0.20 165 15.16 289 723 3.90 / 224.97 2 6
Average= 3.88
(KJ/cycle)

Cycle 56 GMT 1/ 6/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 31 15.12 444 208 0.21 / 217.32 2 3
2 7 2007.80 38 14.75 2966 1662 1.87 / 218.98 2 3
3 13 1426.00 18 14.84 2256 603 2.47 / 219.58 2 3
4 13 852.00 18 14.97 1505 406 2.88 / 219.99 2 3
5 13 395.40 18 15.11 877 239 3.12 / 220.23 2 3
6 13 74.20 18 15.18 406 111 3.23 / 220.34 2 2
7 8 0.04 165 15.16 294 735 3.96 / 221.07 2 9
Average= 3.88
(KJ/cycle)

Cycle 55 GMT 22/ 5/2024 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 31 15.10 432 202 0.20 / 213.40 2 3
2 7 2003.12 38 14.75 2960 1659 1.86 / 215.06 2 3
3 13 1379.04 18 14.85 2194 586 2.45 / 215.64 2 3
4 13 888.28 18 14.96 1559 420 2.87 / 216.06 2 3
5 13 342.56 18 15.12 807 220 3.09 / 216.28 2 3
6 13 44.20 18 15.19 359 98 3.19 / 216.38 2 2
7 8 0.20 165 15.16 291 728 3.91 / 217.11 2 6
Average= 3.88
(KJ/cycle)

Cycle 54 GMT 13/ 5/2024 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 15.12 425 199 0.20 / 209.43 2 3
2 7 2010.44 38 14.75 2974 1667 1.87 / 211.09 2 2
3 13 1399.32 18 14.85 2217 593 2.46 / 211.68 2 3
4 13 828.56 18 14.99 1478 399 2.86 / 212.08 2 3
5 13 475.04 18 15.07 1001 272 3.13 / 212.36 2 3
6 13 48.44 18 15.18 374 102 3.23 / 212.46 2 3
7 8 0.08 165 15.15 295 737 3.97 / 213.19 2 3
Average= 3.88
(KJ/cycle)

Cycle 53 GMT 3/ 5/2024 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 31 15.12 443 208 0.21 / 205.45 2 3
2 7 2004.36 38 14.76 2964 1662 1.87 / 207.12 2 3
3 13 1450.72 18 14.86 2283 611 2.48 / 207.73 2 3
4 13 832.24 18 14.99 1481 400 2.88 / 208.13 2 3
5 13 431.60 18 15.09 941 256 3.14 / 208.38 2 3
6 13 76.48 18 15.19 412 113 3.25 / 208.50 2 3
7 8 0.00 165 15.17 292 731 3.98 / 209.23 2 6
Average= 3.87
(KJ/cycle)

Cycle 52 GMT 23/ 4/2024 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 31 15.14 462 217 0.22 / 201.45 3 3
2 7 2003.28 38 14.77 2968 1666 1.88 / 203.11 2 2
3 13 1454.40 18 14.85 2289 612 2.49 / 203.73 2 3
4 13 943.36 18 14.95 1630 439 2.93 / 204.16 2 3
5 13 397.56 18 15.12 897 244 3.18 / 204.41 2 3
6 13 61.80 18 15.20 392 107 3.28 / 204.52 2 3
7 8 0.16 165 15.18 292 731 4.02 / 205.25 2 4
Average= 3.87
(KJ/cycle)

Cycle 51 GMT 13/ 4/2024 15:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 31 15.14 433 203 0.20 / 197.52 3 3
2 7 2015.72 38 14.75 2977 1669 1.87 / 199.19 2 2
3 13 1378.40 18 14.86 2198 588 2.46 / 199.78 2 3
4 13 837.92 18 15.00 1491 403 2.86 / 200.18 2 3
5 13 353.16 18 15.13 824 224 3.09 / 200.41 2 3
6 13 35.92 18 15.21 351 96 3.18 / 200.50 2 3
7 8 0.32 165 15.18 290 726 3.91 / 201.23 2 8
Average= 3.87
(KJ/cycle)

Cycle 50 GMT 3/ 4/2024 20:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.15 437 205 0.21 / 193.56 3 3
2 7 2011.48 38 14.77 2973 1669 1.87 / 195.23 2 2
3 13 1441.20 18 14.86 2278 609 2.48 / 195.84 2 3
4 13 885.64 18 14.98 1549 418 2.90 / 196.26 2 3
5 13 347.84 18 15.15 821 224 3.12 / 196.48 2 3
6 13 53.44 18 15.22 378 104 3.23 / 196.59 2 2
7 8 0.20 165 15.18 293 734 3.96 / 197.32 2 7
Average= 3.87
(KJ/cycle)

Cycle 49 GMT 25/ 3/2024 1:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 31 15.13 464 218 0.22 / 189.63 2 3
2 7 2003.60 38 14.77 2956 1659 1.88 / 191.29 2 2
3 13 1394.96 18 14.88 2212 592 2.47 / 191.88 2 3
4 13 843.24 18 15.00 1499 405 2.87 / 192.29 2 3
5 13 365.00 18 15.14 845 230 3.10 / 192.52 2 3
6 13 53.64 18 15.21 383 105 3.21 / 192.62 2 3
7 8 0.16 165 15.18 295 739 3.95 / 193.36 2 3
Average= 3.87
(KJ/cycle)

Cycle 48 GMT 15/ 3/2024 6:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 15.14 441 207 0.21 / 185.65 3 3
2 7 2012.52 38 14.77 2966 1665 1.87 / 187.31 2 2
3 13 1431.16 18 14.88 2263 606 2.48 / 187.92 2 3
4 13 902.24 18 14.99 1568 423 2.90 / 188.34 2 3
5 13 364.44 18 15.14 844 230 3.13 / 188.57 2 3
6 13 56.88 18 15.21 386 106 3.24 / 188.67 2 3
7 8 0.12 165 15.18 294 736 3.97 / 189.41 2 8
Average= 3.87
(KJ/cycle)

Cycle 47 GMT 5/ 3/2024 10:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 31 15.14 443 208 0.21 / 181.71 2 3
2 7 2012.44 38 14.76 2978 1670 1.88 / 183.38 2 2
3 13 1432.84 18 14.87 2253 603 2.48 / 183.98 2 3
4 13 808.32 18 15.01 1449 391 2.87 / 184.38 2 3
5 13 368.76 18 15.14 851 232 3.10 / 184.61 2 3
6 13 39.60 18 15.21 355 97 3.20 / 184.70 2 2
7 8 0.04 165 15.18 293 734 3.94 / 185.44 2 7
Average= 3.86
(KJ/cycle)

Cycle 46 GMT 24/ 2/2024 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 31 15.14 427 200 0.20 / 177.76 3 3
2 7 2004.40 38 14.78 2968 1667 1.87 / 179.43 2 2
3 13 1364.52 18 14.89 2183 585 2.45 / 180.01 2 3
4 13 874.24 18 15.00 1543 417 2.87 / 180.43 2 3
5 13 377.52 18 15.14 867 236 3.11 / 180.66 2 3
6 13 43.12 18 15.23 363 100 3.20 / 180.76 2 3
7 8 0.16 165 15.19 295 739 3.94 / 181.50 2 9
Average= 3.86
(KJ/cycle)

Cycle 45 GMT 14/ 2/2024 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 31 15.14 433 203 0.20 / 173.85 3 3
2 7 2008.52 38 14.77 2970 1667 1.87 / 175.51 2 3
3 13 1375.76 18 14.89 2194 588 2.46 / 176.10 2 3
4 13 819.20 18 15.01 1469 397 2.86 / 176.50 2 3
5 13 341.88 18 15.14 813 222 3.08 / 176.72 2 3
6 13 49.04 18 15.22 367 101 3.18 / 176.82 2 3
7 8 0.08 165 15.19 294 737 3.91 / 177.56 2 8
Average= 3.86
(KJ/cycle)

Cycle 44 GMT 5/ 2/2024 1:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.48 31 15.15 466 219 0.22 / 170.00 3 3
2 7 2008.48 38 14.77 2968 1666 1.88 / 171.67 2 3
3 13 1281.80 18 14.91 2059 553 2.44 / 172.22 2 3
4 13 771.76 18 15.04 1404 380 2.82 / 172.60 2 3
5 13 348.72 18 15.15 823 224 3.04 / 172.82 2 3
6 13 24.84 18 15.23 331 91 3.13 / 172.92 2 2
7 8 0.12 165 15.19 291 729 3.86 / 173.64 2 3
Average= 3.86
(KJ/cycle)

Cycle 43 GMT 26/ 1/2024 5:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 15.16 437 205 0.21 / 166.08 3 3
2 7 2011.28 38 14.77 2980 1673 1.88 / 167.75 2 3
3 13 1331.12 18 14.90 2127 570 2.45 / 168.32 2 3
4 13 797.80 18 15.02 1435 388 2.84 / 168.71 2 3
5 13 404.60 18 15.14 909 248 3.08 / 168.96 2 3
6 13 28.36 18 15.23 337 92 3.18 / 169.05 2 3
7 8 0.08 165 15.19 292 732 3.91 / 169.78 2 9
Average= 3.86
(KJ/cycle)

Cycle 42 GMT 16/ 1/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 31 15.16 442 208 0.21 / 162.14 2 3
2 7 2011.64 38 14.76 2975 1669 1.88 / 163.81 2 3
3 13 1388.88 18 14.88 2207 591 2.47 / 164.40 2 3
4 13 898.48 18 15.00 1573 425 2.89 / 164.82 2 3
5 13 359.92 18 15.15 834 227 3.12 / 165.05 2 3
6 13 37.08 18 15.22 349 96 3.22 / 165.15 2 2
7 8 -0.04 165 15.19 290 727 3.94 / 165.87 2 4
Average= 3.86
(KJ/cycle)

Cycle 41 GMT 6/ 1/2024 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 31 15.16 428 201 0.20 / 158.21 2 3
2 7 2010.08 38 14.77 2961 1662 1.86 / 159.87 2 3
3 13 1367.44 18 14.89 2178 584 2.45 / 160.45 2 3
4 13 888.40 18 14.99 1556 420 2.87 / 160.87 2 3
5 13 362.80 18 15.15 841 229 3.10 / 161.10 2 3
6 13 28.80 18 15.23 340 93 3.19 / 161.19 2 3
7 8 0.12 165 15.20 294 737 3.93 / 161.93 2 5
Average= 3.86
(KJ/cycle)

Cycle 40 GMT 27/12/2023 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.16 439 206 0.21 / 154.28 2 3
2 7 2004.04 38 14.78 2966 1666 1.87 / 155.95 2 3
3 13 1356.64 18 14.91 2163 581 2.45 / 156.53 2 2
4 13 861.20 18 15.02 1521 411 2.86 / 156.94 2 3
5 13 400.44 18 15.15 898 245 3.11 / 157.19 2 3
6 13 18.48 18 15.25 324 89 3.20 / 157.28 2 2
7 8 0.16 165 15.21 291 730 3.93 / 158.01 2 4
Average= 3.85
(KJ/cycle)

Cycle 39 GMT 18/12/2023 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 31 15.17 452 213 0.21 / 150.32 3 3
2 7 2007.32 39 14.78 2971 1713 1.93 / 152.04 2 2
3 13 1313.56 18 14.91 2104 565 2.49 / 152.60 2 3
4 13 874.36 18 15.01 1543 417 2.91 / 153.02 2 3
5 13 366.68 18 15.16 849 232 3.14 / 153.25 2 3
6 13 28.60 18 15.24 341 94 3.23 / 153.34 2 3
7 8 0.12 165 15.20 293 735 3.97 / 154.08 2 5
Average= 3.85
(KJ/cycle)

Cycle 38 GMT 8/12/2023 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 31 15.17 425 200 0.20 / 146.33 2 3
2 7 2004.12 38 14.79 2962 1665 1.86 / 147.99 2 2
3 13 1450.48 18 14.89 2290 614 2.48 / 148.60 2 3
4 13 900.96 18 15.01 1576 426 2.90 / 149.03 2 3
5 13 429.68 18 15.14 940 256 3.16 / 149.29 2 3
6 13 33.16 18 15.24 348 95 3.26 / 149.38 2 3
7 8 0.16 165 15.20 291 730 3.99 / 150.11 2 4
Average= 3.85
(KJ/cycle)

Cycle 37 GMT 28/11/2023 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.18 434 204 0.20 / 142.36 3 3
2 7 2012.00 38 14.77 2964 1664 1.87 / 144.03 2 2
3 13 1404.80 18 14.88 2223 595 2.46 / 144.62 2 3
4 13 955.72 18 15.00 1645 444 2.91 / 145.07 2 3
5 13 353.00 18 15.16 829 226 3.13 / 145.29 2 3
6 13 28.24 18 15.24 336 92 3.23 / 145.38 2 2
7 8 0.04 165 15.21 295 740 3.97 / 146.13 2 3
Average= 3.85
(KJ/cycle)

Cycle 36 GMT 18/11/2023 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 31 15.18 463 218 0.22 / 138.44 2 3
2 7 2005.32 38 14.78 2957 1661 1.88 / 140.10 2 2
3 13 1370.40 18 14.91 2175 584 2.46 / 140.69 2 3
4 13 872.04 18 15.02 1536 415 2.88 / 141.10 2 3
5 13 372.92 18 15.17 853 233 3.11 / 141.34 2 3
6 13 15.36 18 15.25 321 88 3.20 / 141.42 2 3
7 8 0.08 165 15.22 293 736 3.93 / 142.16 2 4
Average= 3.84
(KJ/cycle)

Cycle 35 GMT 8/11/2023 20:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 31 15.19 438 206 0.21 / 134.47 3 3
2 7 2003.00 38 14.78 2950 1657 1.86 / 136.13 2 2
3 13 1407.04 18 14.89 2225 596 2.46 / 136.72 2 3
4 13 901.92 18 15.01 1574 425 2.88 / 137.15 2 3
5 13 392.12 18 15.16 883 241 3.13 / 137.39 2 3
6 13 18.52 18 15.26 323 89 3.21 / 137.48 2 3
7 8 0.08 165 15.21 297 745 3.96 / 138.22 2 4
Average= 3.84
(KJ/cycle)

Cycle 34 GMT 30/10/2023 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.20 438 206 0.21 / 130.46 2 3
2 7 2003.80 38 14.79 2968 1668 1.87 / 132.13 2 2
3 13 1484.44 18 14.88 2325 623 2.50 / 132.75 2 2
4 13 942.56 18 15.01 1622 438 2.94 / 133.19 2 3
5 13 406.68 18 15.17 903 247 3.18 / 133.43 2 3
6 13 21.20 18 15.27 328 90 3.27 / 133.52 2 3
7 8 0.08 165 15.23 295 741 4.01 / 134.26 2 5
Average= 3.84
(KJ/cycle)

Cycle 33 GMT 20/10/2023 6:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 31 15.20 459 216 0.22 / 126.61 2 3
2 7 2012.48 39 14.79 2972 1714 1.93 / 128.33 2 3
3 13 1338.00 18 14.93 2141 575 2.51 / 128.90 2 3
4 13 807.28 18 15.04 1450 393 2.90 / 129.29 2 3
5 13 329.52 18 15.19 795 217 3.12 / 129.51 2 3
6 8 0.16 165 15.24 294 739 3.86 / 130.25 2 4
Average= 3.83
(KJ/cycle)

Cycle 32 GMT 10/10/2023 11:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.18 441 208 0.21 / 122.71 2 3
2 7 2009.00 39 14.80 2972 1715 1.92 / 124.42 2 2
3 13 1458.36 18 14.91 2300 617 2.54 / 125.04 2 3
4 13 793.08 18 15.06 1425 386 2.93 / 125.42 2 3
5 13 368.08 18 15.18 850 232 3.16 / 125.66 2 3
6 8 0.08 165 15.24 294 739 3.90 / 126.40 2 5
Average= 3.83
(KJ/cycle)

Cycle 31 GMT 30/ 9/2023 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 31 15.20 463 218 0.22 / 118.87 2 3
2 7 2003.60 38 14.80 2957 1663 1.88 / 120.53 2 3
3 13 1365.36 18 14.93 2169 583 2.46 / 121.12 2 3
4 13 889.72 18 15.04 1558 422 2.89 / 121.54 2 3
5 13 346.92 18 15.19 817 223 3.11 / 121.76 2 3
6 8 0.16 165 15.25 293 737 3.85 / 122.50 2 4
Average= 3.83
(KJ/cycle)

Cycle 30 GMT 20/ 9/2023 20:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 31 15.21 457 215 0.22 / 114.97 2 3
2 7 2016.76 38 14.80 2974 1673 1.89 / 116.64 2 3
3 13 1442.76 18 14.91 2271 609 2.50 / 117.25 2 3
4 13 901.72 18 15.04 1573 426 2.92 / 117.68 2 3
5 13 361.56 18 15.19 838 229 3.15 / 117.91 2 3
6 8 0.04 165 15.24 296 744 3.90 / 118.65 2 6
Average= 3.83
(KJ/cycle)

Cycle 29 GMT 11/ 9/2023 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 31 15.23 445 210 0.21 / 111.08 2 3
2 7 2009.96 38 14.79 2967 1668 1.88 / 112.75 2 3
3 13 1405.48 18 14.92 2232 599 2.48 / 113.35 2 3
4 13 914.96 18 15.03 1591 430 2.91 / 113.78 2 3
5 13 373.52 18 15.18 858 234 3.14 / 114.02 2 3
6 8 0.16 165 15.25 294 740 3.88 / 114.75 2 6
Average= 3.83
(KJ/cycle)

Cycle 28 GMT 1/ 9/2023 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 31 15.21 433 204 0.20 / 107.64 2 3
2 7 1555.00 38 14.97 2399 1365 1.57 / 109.01 2 2
3 13 1244.84 18 15.01 2020 546 2.11 / 109.55 2 3
4 13 761.32 18 15.12 1388 378 2.49 / 109.93 2 3
5 13 304.60 18 15.24 748 205 2.70 / 110.14 2 3
6 8 0.12 165 15.27 293 738 3.44 / 110.87 2 3
Average= 3.82
(KJ/cycle)

Cycle 27 GMT 22/ 8/2023 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 31 15.21 468 221 0.22 / 103.77 2 3
2 7 2013.44 39 14.81 2966 1713 1.93 / 105.49 2 2
3 13 1369.44 18 14.93 2183 587 2.52 / 106.07 2 3
4 13 809.20 18 15.06 1451 393 2.91 / 106.47 2 3
5 13 371.32 18 15.19 854 234 3.15 / 106.70 2 3
6 8 0.08 165 15.25 293 737 3.88 / 107.44 2 4
Average= 3.84
(KJ/cycle)

Cycle 26 GMT 12/ 8/2023 13:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.96 31 15.22 469 221 0.22 / 99.85 2 3
2 7 2005.88 38 14.81 2958 1665 1.89 / 101.51 2 3
3 13 1314.36 18 14.95 2111 568 2.45 / 102.08 2 3
4 13 833.12 18 15.07 1481 402 2.86 / 102.48 2 3
5 13 383.60 18 15.19 866 237 3.09 / 102.72 2 3
6 13 35.44 18 15.28 342 94 3.19 / 102.82 2 2
7 8 0.00 165 15.25 293 737 3.92 / 103.55 2 4
Average= 3.84
(KJ/cycle)

Cycle 25 GMT 2/ 8/2023 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 31 15.22 466 220 0.22 / 95.95 2 3
2 7 2003.80 38 14.83 2954 1665 1.88 / 97.61 2 3
3 13 1391.32 18 14.94 2209 594 2.48 / 98.21 2 3
4 13 920.00 18 15.05 1592 431 2.91 / 98.64 2 3
5 13 424.96 18 15.18 929 254 3.16 / 98.89 2 3
6 8 0.28 165 15.27 292 736 3.90 / 99.63 2 4
Average= 3.83
(KJ/cycle)

Cycle 24 GMT 23/ 7/2023 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 31 15.22 438 207 0.21 / 91.98 2 3
2 7 2010.40 38 14.83 2974 1676 1.88 / 93.65 2 2
3 13 1545.00 18 14.92 2406 646 2.53 / 94.30 2 3
4 13 967.44 18 15.05 1660 450 2.98 / 94.75 2 3
5 13 407.52 18 15.21 910 249 3.23 / 95.00 2 3
6 8 0.04 165 15.27 290 731 3.96 / 95.73 2 3
Average= 3.83
(KJ/cycle)

Cycle 23 GMT 14/ 7/2023 4:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 31 15.24 456 215 0.22 / 88.14 3 3
2 7 2008.36 38 14.83 2960 1668 1.88 / 89.81 2 2
3 13 1440.72 18 14.96 2273 612 2.50 / 90.42 2 3
4 13 805.64 18 15.10 1448 394 2.89 / 90.81 2 3
5 13 334.28 18 15.23 801 220 3.11 / 91.03 2 3
6 8 0.16 165 15.28 293 739 3.85 / 91.77 2 4
Average= 3.82
(KJ/cycle)

Cycle 22 GMT 4/ 7/2023 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 31 15.22 449 212 0.21 / 84.34 3 3
2 7 2003.04 38 14.83 2958 1667 1.88 / 86.01 2 3
3 13 1232.96 18 15.01 2006 542 2.42 / 86.55 2 3
4 13 851.04 18 15.10 1511 411 2.83 / 86.96 2 3
5 13 359.60 18 15.23 835 229 3.06 / 87.19 2 3
6 8 0.20 165 15.28 292 736 3.80 / 87.92 2 4
Average= 3.82
(KJ/cycle)

Cycle 21 GMT 24/ 6/2023 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 15.23 441 208 0.21 / 80.49 3 3
2 7 2010.92 38 14.83 2968 1673 1.88 / 82.16 2 2
3 13 1374.68 18 14.97 2182 588 2.47 / 82.75 2 3
4 13 785.80 18 15.11 1408 383 2.85 / 83.13 2 3
5 13 397.48 18 15.22 892 244 3.10 / 83.38 2 3
6 8 0.12 165 15.27 298 751 3.85 / 84.13 2 3
Average= 3.82
(KJ/cycle)

Cycle 20 GMT 14/ 6/2023 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 31 15.23 458 216 0.22 / 76.67 3 3
2 7 2006.72 38 14.84 2958 1668 1.88 / 78.34 2 3
3 13 1481.68 18 14.95 2325 626 2.51 / 78.96 2 3
4 13 773.16 18 15.11 1398 380 2.89 / 79.34 2 3
5 13 296.24 18 15.25 737 202 3.09 / 79.54 2 3
6 8 0.28 165 15.27 292 736 3.83 / 80.28 2 4
Average= 3.82
(KJ/cycle)

Cycle 19 GMT 4/ 6/2023 23:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 31 15.25 430 203 0.20 / 72.73 3 3
2 7 2003.48 38 14.85 2963 1672 1.88 / 74.40 2 3
3 13 1390.44 18 14.98 2215 597 2.47 / 75.00 2 3
4 13 786.80 18 15.12 1425 388 2.86 / 75.39 2 3
5 13 349.72 18 15.25 823 226 3.09 / 75.61 2 3
6 13 41.60 18 15.31 362 100 3.19 / 75.71 2 2
7 8 0.04 165 15.28 294 741 3.93 / 76.45 2 4
Average= 3.82
(KJ/cycle)

Cycle 18 GMT 26/ 5/2023 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 15.25 446 211 0.21 / 68.73 3 3
2 7 2011.88 38 14.85 2975 1679 1.89 / 70.41 2 2
3 13 1478.68 18 14.95 2324 625 2.52 / 71.04 2 3
4 13 879.08 18 15.09 1540 418 2.93 / 71.46 2 3
5 13 376.28 18 15.23 860 236 3.17 / 71.69 2 3
6 13 36.60 18 15.30 348 96 3.26 / 71.79 2 2
7 8 0.00 165 15.28 292 736 4.00 / 72.52 2 4
Average= 3.82
(KJ/cycle)

Cycle 17 GMT 16/ 5/2023 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 15.25 441 202 0.20 / 64.71 3 3
2 7 2005.44 39 14.85 2971 1721 1.92 / 66.43 2 3
3 13 1361.68 18 14.98 2181 588 2.51 / 67.02 2 3
4 13 867.00 18 15.10 1530 416 2.93 / 67.44 2 3
5 13 403.36 18 15.22 904 248 3.17 / 67.69 2 3
6 13 44.44 18 15.31 361 99 3.27 / 67.79 2 2
7 8 0.20 165 15.28 293 739 4.01 / 68.52 2 4
Average= 3.81
(KJ/cycle)

Cycle 16 GMT 6/ 5/2023 13:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 15.25 432 198 0.20 / 60.71 3 3
2 7 2006.24 38 14.87 2972 1679 1.88 / 62.39 2 2
3 13 1430.60 18 14.98 2266 611 2.49 / 63.00 2 2
4 13 917.72 18 15.09 1593 433 2.92 / 63.44 2 3
5 13 359.76 18 15.25 839 230 3.15 / 63.67 2 3
6 13 62.28 18 15.32 389 107 3.26 / 63.77 2 2
7 8 0.16 165 15.29 292 737 3.99 / 64.51 2 3
Average= 3.79
(KJ/cycle)

Cycle 15 GMT 26/ 4/2023 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 15.24 431 197 0.20 / 56.72 3 3
2 7 2010.84 39 14.87 2983 1730 1.93 / 58.45 2 2
3 13 1340.00 18 15.00 2151 581 2.51 / 59.03 2 3
4 13 874.40 18 15.10 1544 420 2.93 / 59.45 2 3
5 13 328.64 18 15.25 795 218 3.15 / 59.67 2 3
6 13 42.24 18 15.31 366 101 3.25 / 59.77 2 2
7 8 0.16 165 15.28 295 744 3.99 / 60.52 2 4
Average= 3.78
(KJ/cycle)

Cycle 14 GMT 16/ 4/2023 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 15.25 449 205 0.21 / 52.85 3 3
2 7 1895.56 38 14.89 2834 1604 1.81 / 54.45 2 2
3 13 1434.52 18 14.98 2273 613 2.42 / 55.06 2 3
4 13 785.44 18 15.13 1426 388 2.81 / 55.45 2 3
5 13 334.72 18 15.26 806 221 3.03 / 55.67 2 3
6 13 40.04 18 15.33 364 100 3.13 / 55.77 2 2
7 8 0.12 165 15.29 298 752 3.88 / 56.53 2 4
Average= 3.77
(KJ/cycle)

Cycle 13 GMT 7/ 4/2023 1:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 15.26 436 200 0.20 / 48.91 3 3
2 7 2013.56 38 14.86 2974 1679 1.88 / 50.59 2 3
3 13 1400.72 18 14.99 2227 601 2.48 / 51.19 2 3
4 13 813.12 18 15.12 1464 398 2.88 / 51.59 2 3
5 13 318.72 18 15.25 779 214 3.09 / 51.80 2 3
6 13 31.88 18 15.32 349 96 3.19 / 51.90 2 2
7 8 0.20 165 15.29 296 747 3.94 / 52.64 2 4
Average= 3.76
(KJ/cycle)

Cycle 12 GMT 28/ 3/2023 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 30 15.25 457 209 0.21 / 44.84 3 3
2 7 2010.96 38 14.88 2980 1685 1.89 / 46.52 2 3
3 13 1464.68 18 15.00 2307 623 2.52 / 47.14 2 3
4 13 990.68 18 15.09 1702 462 2.98 / 47.61 2 3
5 13 396.96 18 15.25 900 247 3.23 / 47.85 2 3
6 13 41.96 18 15.33 361 100 3.33 / 47.95 2 3
7 8 -0.04 165 15.29 299 754 4.08 / 48.71 2 4
Average= 3.75
(KJ/cycle)

Cycle 11 GMT 18/ 3/2023 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 30 15.26 447 205 0.20 / 40.91 2 3
2 7 2005.84 38 14.87 2968 1677 1.88 / 42.58 2 2
3 13 1402.20 18 14.99 2228 601 2.48 / 43.18 2 2
4 13 805.44 18 15.13 1449 395 2.88 / 43.58 2 3
5 13 302.00 18 15.27 753 207 3.08 / 43.79 2 3
6 13 30.84 18 15.33 343 95 3.18 / 43.88 2 2
7 8 0.12 165 15.30 296 747 3.93 / 44.63 2 5
Average= 3.72
(KJ/cycle)

Cycle 10 GMT 8/ 3/2023 16:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 30 15.26 433 198 0.20 / 36.92 3 3
2 7 2006.28 38 14.88 2968 1678 1.88 / 38.60 2 2
3 13 1434.64 18 15.00 2272 613 2.49 / 39.21 2 2
4 13 772.48 18 15.15 1407 384 2.87 / 39.59 2 2
5 13 380.08 18 15.26 869 239 3.11 / 39.83 2 3
6 13 76.40 18 15.33 418 115 3.23 / 39.95 2 2
7 8 0.12 165 15.29 299 754 3.98 / 40.70 2 4
Average= 3.70
(KJ/cycle)

Cycle 9 GMT 26/ 2/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 15.26 435 199 0.20 / 33.00 2 3
2 7 2006.48 38 14.88 2967 1678 1.88 / 34.68 2 2
3 13 1305.40 18 15.03 2102 569 2.45 / 35.25 2 2
4 13 820.56 18 15.13 1470 400 2.85 / 35.65 2 3
5 13 375.16 18 15.25 860 236 3.08 / 35.88 2 3
6 13 24.84 18 15.33 333 92 3.17 / 35.97 2 3
7 8 0.12 165 15.30 295 745 3.92 / 36.72 2 4
Average= 3.67
(KJ/cycle)

Cycle 8 GMT 17/ 2/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 30 15.27 460 211 0.21 / 29.09 3 3
2 3 1019.16 1 15.31 1761 27 0.24 / 29.12 2 2
3 7 2012.40 38 14.88 2973 1681 1.92 / 30.80 2 2
4 13 1279.52 18 15.03 2070 560 2.48 / 31.36 2 2
5 13 806.32 18 15.14 1447 394 2.87 / 31.75 2 2
6 13 336.28 18 15.27 794 218 3.09 / 31.97 2 2
7 13 13.76 18 15.34 314 87 3.18 / 32.06 2 2
8 8 0.20 165 15.30 294 742 3.92 / 32.80 2 4
Average= 3.64
(KJ/cycle)

Cycle 7 GMT 7/ 2/2023 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 29 15.27 455 201 0.20 / 25.17 3 3
2 7 2009.68 38 14.88 2963 1675 1.88 / 26.85 2 2
3 13 1306.96 18 15.03 2104 569 2.45 / 27.42 2 2
4 13 811.68 18 15.14 1446 394 2.84 / 27.81 2 2
5 13 377.52 18 15.26 857 235 3.08 / 28.05 2 2
6 13 23.56 18 15.33 327 90 3.17 / 28.14 2 2
7 8 0.04 165 15.30 294 742 3.91 / 28.88 2 4
Average= 3.61
(KJ/cycle)

Cycle 6 GMT 28/ 1/2023 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 15.27 432 191 0.19 / 20.62 2 3
2 3 1037.72 1 15.30 1814 28 0.22 / 20.65 2 2
3 7 2004.24 74 14.78 2946 3222 3.44 / 23.87 2 2
4 13 435.72 18 15.26 941 258 3.70 / 24.13 2 3
5 13 85.04 18 15.34 418 115 3.82 / 24.24 2 2
6 8 0.24 165 15.32 289 731 4.55 / 24.97 2 4
Average= 3.57
(KJ/cycle)

Cycle 5 GMT 18/ 1/2023 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 29 15.28 468 207 0.21 / 16.03 3 3
2 7 2007.96 74 14.78 2951 3228 3.43 / 19.25 2 2
3 13 524.20 18 15.22 1067 292 3.73 / 19.55 2 3
4 13 109.84 18 15.33 458 126 3.85 / 19.67 2 2
5 8 0.08 165 15.31 298 753 4.61 / 20.43 2 5
Average= 3.40
(KJ/cycle)

Cycle 4 GMT 8/ 1/2023 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 15.28 439 188 0.19 / 12.17 2 3
2 7 1528.00 74 14.97 2348 2601 2.79 / 14.77 2 2
3 13 323.48 18 15.31 783 216 3.00 / 14.98 2 2
4 13 19.80 18 15.36 326 90 3.09 / 15.07 2 2
5 8 0.08 165 15.32 295 746 3.84 / 15.82 2 5
Average= 3.16
(KJ/cycle)

Cycle 3 GMT 7/ 1/2023 17:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 27 15.27 461 190 0.19 / 8.28 3 3
2 10 1003.88 2 15.28 1741 53 0.24 / 8.33 2 2
3 7 1520.84 74 14.97 2343 2596 2.84 / 10.93 2 2
4 13 300.52 18 15.30 744 205 3.04 / 11.14 2 3
5 13 34.04 18 15.35 348 96 3.14 / 11.23 2 2
6 8 0.04 165 15.32 296 748 3.89 / 11.98 2 4
Average= 2.99
(KJ/cycle)

Cycle 2 GMT 6/ 1/2023 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 31 15.32 443 210 0.21 / 4.47 2 3
2 3 866.12 -3 15.68 0 0 0.00 / 4.47 2 3
3 7 1517.48 74 14.99 2332 2587 2.80 / 7.06 2 2
4 13 283.24 18 15.32 718 198 3.00 / 7.25 2 2
5 13 29.72 18 15.36 338 93 3.09 / 7.35 2 2
6 8 0.04 165 15.32 294 743 3.83 / 8.09 2 4
Average= 2.70
(KJ/cycle)

Cycle 1 GMT 5/ 1/2023 18:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 26 15.51 397 160 0.16 / 1.60 3 3
2 10 1008.92 2 15.38 1718 53 0.21 / 1.65 2 2
3 7 989.20 75 15.18 1641 1868 2.08 / 3.52 2 3
4 8 0.04 165 15.38 291 738 2.82 / 4.26 2 4
Average= 2.13
(KJ/cycle)

Cycle 0 GMT 5/ 1/2023 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 79.04 26 15.66 352 143 0.14 / 0.14 3 3
2 7 95.32 74 15.63 377 436 0.58 / 0.58 3 3
3 8 0.36 240 15.59 230 861 1.44 / 1.44 3 5
Average= 1.44
(KJ/cycle)