SIO Argo Site:
Pump Diagnostics Page   



Serial= 8407 WMO= 5902420

Return

←PreviousNext→

Cycle 299 GMT 25/ 2/2023 16:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 40 10.75 392 169 0.17 / 1476.03 2 2
2 3 894.28 -1 10.75 392 0 0.00 / 1476.03 2 2
3 12 1158.72 90 7.30 1923 1263 1.43 / 1477.29 2 2
4 7 1161.04 25 7.30 1948 356 1.79 / 1477.65 2 2
5 13 1021.04 38 7.75 1748 515 2.30 / 1478.16 2 2
6 13 665.40 38 8.74 1249 415 2.72 / 1478.57 2 2
7 13 71.84 38 10.63 359 145 2.86 / 1478.72 2 2
8 8 -0.16 180 10.88 249 488 3.35 / 1479.21 2 2
Average= 4.93 (KJ/cycle)

Cycle 298 GMT 15/ 2/2023 21:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 37 10.74 415 165 0.16 / 1472.63 2 2
2 3 1018.32 1 8.16 1748 14 0.18 / 1472.65 2 2
3 12 1193.76 90 7.35 1978 1308 1.49 / 1473.96 2 2
4 7 1197.24 25 7.30 2000 365 1.85 / 1474.32 2 2
5 13 1053.28 38 7.78 1797 531 2.38 / 1474.85 2 2
6 13 521.80 38 9.21 1052 368 2.75 / 1475.22 2 2
7 13 76.16 38 10.66 364 147 2.90 / 1475.37 2 2
8 8 -0.20 180 10.90 250 490 3.39 / 1475.86 2 2
Average= 4.94 (KJ/cycle)

Cycle 297 GMT 6/ 2/2023 2:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 35 10.73 392 147 0.15 / 1469.20 2 2
2 3 1029.80 1 8.24 1766 15 0.16 / 1469.22 2 2
3 3 1023.12 1 8.35 1751 15 0.18 / 1469.23 2 2
4 12 1189.80 90 7.51 1969 1331 1.51 / 1470.56 2 2
5 7 1191.20 25 7.43 1985 369 1.88 / 1470.93 2 2
6 13 1030.40 38 7.96 1765 534 2.41 / 1471.46 2 2
7 13 467.80 38 9.43 992 355 2.77 / 1471.82 2 2
8 13 63.04 38 10.70 355 144 2.91 / 1471.96 2 2
9 8 -0.36 180 10.90 257 504 3.41 / 1472.47 2 2
Average= 4.94 (KJ/cycle)

Cycle 296 GMT 27/ 1/2023 7:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 34 10.68 416 151 0.15 / 1459.62 2 2
2 10 1041.68 5 7.88 1804 71 0.22 / 1459.69 2 2
3 3 1023.20 1 8.09 1758 14 0.24 / 1459.71 2 2
4 3 1016.36 1 8.01 1740 14 0.25 / 1459.72 2 2
5 12 1158.56 3 7.50 1927 43 0.29 / 1459.76 2 2
6 12 1963.52 90 5.00 2925 1316 1.61 / 1461.08 2 2
7 7 1963.92 25 4.95 2648 328 1.94 / 1461.41 2 2
8 13 1969.96 38 5.08 3134 605 2.54 / 1462.01 2 2
9 13 1973.44 38 5.10 3200 620 3.16 / 1462.63 2 2
10 13 1971.44 38 5.10 3251 630 3.79 / 1463.26 2 2
11 13 1955.28 38 5.19 3221 635 4.43 / 1463.90 2 2
12 13 1917.72 38 5.51 3111 651 5.08 / 1464.55 2 2
13 13 1868.44 38 5.72 2986 649 5.73 / 1465.20 2 2
14 13 1766.88 38 6.06 2840 654 6.38 / 1465.85 2 2
15 13 1641.40 38 6.47 2634 648 7.03 / 1466.50 2 2
16 13 1494.44 38 6.78 2419 623 7.65 / 1467.12 2 2
17 13 1325.56 38 7.32 2187 608 8.26 / 1467.73 2 2
18 13 773.32 38 8.68 1421 469 8.73 / 1468.20 2 2
19 13 196.72 38 10.30 566 222 8.95 / 1468.42 2 2
20 13 34.04 38 10.80 303 124 9.08 / 1468.55 2 2
21 8 -0.40 180 10.90 258 506 9.58 / 1469.05 2 2
Average= 4.95 (KJ/cycle)

Cycle 295 GMT 26/ 1/2023 0:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 34 10.78 407 149 0.15 / 1456.27 2 2
2 10 1043.52 6 8.33 1783 89 0.24 / 1456.36 2 2
3 12 1180.00 90 7.12 1961 1257 1.49 / 1457.61 2 2
4 7 1182.24 25 6.88 1973 339 1.83 / 1457.95 2 2
5 13 1025.92 38 7.81 1756 521 2.36 / 1458.47 2 2
6 13 526.84 38 9.19 1058 369 2.72 / 1458.84 2 2
7 13 85.56 38 10.63 371 150 2.87 / 1458.99 2 2
8 8 -0.24 180 10.87 244 477 3.35 / 1459.47 2 2
Average= 4.93 (KJ/cycle)

Cycle 294 GMT 16/ 1/2023 5:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 34 11.02 393 147 0.15 / 1452.97 2 2
2 3 1014.40 1 8.89 1788 16 0.16 / 1452.99 2 2
3 12 1176.96 90 7.61 1955 1339 1.50 / 1454.33 2 2
4 7 1177.48 25 7.41 1961 363 1.87 / 1454.69 2 2
5 13 1012.24 38 8.22 1734 542 2.41 / 1455.23 2 2
6 13 318.40 38 9.95 753 285 2.69 / 1455.52 2 2
7 13 37.36 38 10.83 298 123 2.81 / 1455.64 2 2
8 8 -0.32 180 10.92 243 478 3.29 / 1456.12 2 2
Average= 4.94 (KJ/cycle)

Cycle 293 GMT 6/ 1/2023 10:35: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 11.40 405 143 0.14 / 1449.50 2 2
2 3 1064.64 3 9.69 1836 53 0.20 / 1449.56 2 2
3 12 1191.68 90 7.86 1986 1405 1.60 / 1450.96 2 2
4 7 1194.08 25 7.68 1986 381 1.98 / 1451.34 2 2
5 13 1020.28 38 8.50 1758 568 2.55 / 1451.91 2 2
6 13 285.80 38 10.27 702 274 2.82 / 1452.19 2 2
7 13 63.80 38 10.97 347 145 2.97 / 1452.33 2 2
8 8 -0.28 180 11.13 248 497 3.47 / 1452.83 2 2
Average= 4.94 (KJ/cycle)

Cycle 292 GMT 27/12/2022 15:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 11.68 396 134 0.13 / 1443.74 2 2
2 3 1096.80 4 9.68 1900 74 0.21 / 1443.81 2 2
3 3 1017.48 1 9.80 1772 17 0.23 / 1443.83 2 2
4 12 1179.20 3 9.49 2011 57 0.28 / 1443.88 2 2
5 12 1948.56 90 6.69 3097 1865 2.15 / 1445.75 2 2
6 7 1940.88 25 5.17 2961 383 2.53 / 1446.13 2 2
7 13 1794.36 38 7.36 2861 800 3.33 / 1446.93 2 2
8 13 1623.64 38 7.70 2645 774 4.10 / 1447.71 2 2
9 13 1065.92 38 8.96 1861 634 4.74 / 1448.34 2 2
10 13 320.12 38 10.61 783 316 5.05 / 1448.65 2 2
11 13 63.24 38 11.28 369 158 5.21 / 1448.81 2 2
12 8 -0.16 180 11.33 269 549 5.76 / 1449.36 2 2
Average= 4.95 (KJ/cycle)

Cycle 291 GMT 26/12/2022 11:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 25 12.17 412 125 0.13 / 1440.05 2 2
2 10 1032.16 9 10.72 1791 173 0.30 / 1440.23 2 2
3 12 1186.76 90 6.10 1937 1063 1.36 / 1441.29 2 2
4 7 1192.20 25 7.03 1965 345 1.71 / 1441.64 2 2
5 13 1067.56 38 8.45 1818 584 2.29 / 1442.22 2 2
6 13 896.00 38 9.08 1589 548 2.84 / 1442.77 2 2
7 13 297.12 38 10.80 736 302 3.14 / 1443.07 2 2
8 8 -0.24 180 11.66 253 531 3.67 / 1443.60 2 2
Average= 4.94 (KJ/cycle)

Cycle 290 GMT 16/12/2022 16:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 13.00 435 158 0.16 / 1436.40 2 2
2 3 1068.64 3 11.67 1895 66 0.22 / 1436.47 2 2
3 3 1013.76 1 11.39 1812 21 0.25 / 1436.49 2 2
4 12 1193.40 90 7.42 1982 1324 1.57 / 1437.81 2 2
5 7 1196.36 25 8.72 2011 438 2.01 / 1438.25 2 2
6 13 1026.56 38 9.51 1787 646 2.65 / 1438.89 2 2
7 13 280.12 38 11.48 725 316 2.97 / 1439.21 2 2
8 13 24.56 38 12.18 304 141 3.11 / 1439.35 2 2
9 8 -0.32 180 12.08 266 578 3.69 / 1439.93 2 2
Average= 4.95 (KJ/cycle)

Cycle 289 GMT 6/12/2022 21:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 27 13.66 423 156 0.16 / 1432.78 2 2
2 3 1019.08 1 11.85 1847 22 0.18 / 1432.80 2 2
3 12 1185.04 90 7.62 1979 1357 1.54 / 1434.16 2 2
4 7 1187.16 25 9.01 2022 455 1.99 / 1434.61 2 2
5 13 1015.80 38 9.91 1798 677 2.67 / 1435.29 2 2
6 13 242.48 38 12.21 674 313 2.98 / 1435.60 2 2
7 8 -0.24 180 12.82 276 637 3.62 / 1436.24 2 2
Average= 4.95 (KJ/cycle)

Cycle 288 GMT 27/11/2022 3:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 24 14.03 440 148 0.15 / 1427.48 2 2
2 10 1052.68 5 12.35 1877 116 0.26 / 1427.60 2 2
3 12 1179.00 3 11.36 2051 70 0.33 / 1427.67 2 2
4 12 1905.04 90 8.93 3059 2459 2.79 / 1430.13 2 2
5 7 1894.00 25 9.05 3042 688 3.48 / 1430.82 2 2
6 13 1103.24 38 10.90 1946 806 4.29 / 1431.62 2 2
7 13 275.60 38 12.67 723 348 4.63 / 1431.97 2 2
8 8 -0.28 180 13.26 274 654 5.29 / 1432.62 2 2
Average= 4.96 (KJ/cycle)

Cycle 287 GMT 25/11/2022 23:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 14.18 422 168 0.17 / 1422.96 2 2
2 3 957.40 -1 14.18 422 0 0.00 / 1422.96 2 2
3 3 1023.96 1 11.38 1847 21 0.19 / 1422.99 2 2
4 12 1190.24 90 4.75 1846 789 0.98 / 1423.77 2 2
5 7 1197.88 25 8.25 2010 415 1.39 / 1424.19 2 2
6 13 1281.16 38 8.71 2142 709 2.10 / 1424.90 2 2
7 13 1186.72 38 9.55 2018 732 2.83 / 1425.63 2 2
8 13 1026.64 38 10.28 1803 704 3.54 / 1426.33 2 2
9 13 240.48 38 12.97 666 328 3.87 / 1426.66 2 2
10 8 -0.24 180 13.57 275 672 4.54 / 1427.33 2 2
Average= 4.96 (KJ/cycle)

Cycle 286 GMT 16/11/2022 3:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 27 14.23 451 173 0.17 / 1418.54 2 2
2 12 1195.12 90 4.72 1701 723 0.90 / 1419.26 2 2
3 7 1207.28 25 8.04 2019 406 1.30 / 1419.67 2 2
4 13 1293.16 38 8.55 2156 700 2.00 / 1420.37 2 2
5 13 1198.76 38 9.80 2048 763 2.76 / 1421.13 2 2
6 13 861.08 38 11.57 1595 701 3.47 / 1421.83 2 2
7 13 135.48 38 13.88 493 260 3.73 / 1422.09 2 2
8 8 -0.24 180 14.09 278 705 4.43 / 1422.80 2 2
Average= 4.96 (KJ/cycle)

Cycle 285 GMT 6/11/2022 8: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 25 14.35 422 151 0.15 / 1414.59 2 2
2 3 1048.24 2 12.05 1861 45 0.20 / 1414.64 2 2
3 12 1199.12 90 5.70 1961 1006 1.20 / 1415.64 2 2
4 7 1206.44 25 8.99 2048 460 1.66 / 1416.10 2 2
5 13 1080.44 38 10.37 1886 743 2.41 / 1416.85 2 2
6 13 566.68 38 12.70 1184 571 2.98 / 1417.42 2 2
7 13 70.88 38 14.08 403 216 3.19 / 1417.63 2 2
8 8 -0.16 180 14.15 288 734 3.93 / 1418.37 2 3
Average= 4.96 (KJ/cycle)

Cycle 284 GMT 27/10/2022 13:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 14.30 437 175 0.17 / 1409.33 2 2
2 3 929.44 -1 14.30 437 0 0.00 / 1409.33 2 2
3 12 1177.68 3 10.97 2041 67 0.24 / 1409.40 2 2
4 12 1929.80 90 8.50 3075 2352 2.59 / 1411.75 2 2
5 7 1919.36 25 9.46 3093 731 3.33 / 1412.48 2 2
6 13 1146.00 38 12.12 2009 925 4.25 / 1413.41 2 2
7 13 155.84 38 13.99 550 292 4.54 / 1413.70 2 2
8 8 -0.20 180 14.29 287 738 5.28 / 1414.44 2 2
Average= 4.96 (KJ/cycle)

Cycle 283 GMT 26/10/2022 9: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 26 14.31 428 159 0.16 / 1404.62 2 2
2 3 1021.32 1 11.30 1813 20 0.18 / 1404.64 2 2
3 3 1014.88 1 10.87 1817 20 0.20 / 1404.66 2 2
4 12 1179.64 90 4.74 1788 763 0.96 / 1405.43 2 2
5 7 1190.88 25 8.82 2011 443 1.41 / 1405.87 2 2
6 13 1270.28 38 9.87 2152 807 2.21 / 1406.68 2 2
7 13 1149.08 38 10.73 2011 820 3.03 / 1407.50 2 2
8 13 787.92 38 12.19 1504 697 3.73 / 1408.19 2 2
9 13 81.60 38 14.13 420 226 3.95 / 1408.42 2 2
10 8 -0.12 180 14.30 287 739 4.69 / 1409.16 2 2
Average= 4.96 (KJ/cycle)

Cycle 282 GMT 16/10/2022 13:43:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.31 432 167 0.17 / 1399.91 2 2
2 3 950.76 -1 14.31 432 0 0.00 / 1399.91 2 2
3 3 1023.36 1 11.30 1831 21 0.19 / 1399.93 2 2
4 12 1197.88 90 4.75 1864 797 0.98 / 1400.73 2 2
5 7 1209.88 25 8.91 2034 453 1.44 / 1401.18 2 2
6 13 1303.08 38 9.79 2195 817 2.25 / 1402.00 2 2
7 13 1174.52 38 10.81 2024 831 3.09 / 1402.83 2 2
8 13 801.92 38 12.24 1517 706 3.79 / 1403.53 2 2
9 13 77.48 38 14.15 402 216 4.01 / 1403.75 2 2
10 8 -0.16 180 14.33 277 714 4.72 / 1404.46 2 3
Average= 4.96 (KJ/cycle)

Cycle 281 GMT 6/10/2022 18:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 27 14.30 451 174 0.17 / 1396.15 2 2
2 12 1195.80 90 5.93 1954 1043 1.22 / 1397.19 2 2
3 7 1202.32 25 9.15 2039 466 1.68 / 1397.66 2 2
4 13 1063.56 38 11.05 1872 786 2.47 / 1398.45 2 2
5 13 524.60 38 12.96 1119 551 3.02 / 1399.00 2 2
6 8 -0.12 180 14.30 289 744 3.76 / 1399.74 2 2
Average= 4.96 (KJ/cycle)

Cycle 280 GMT 26/ 9/2022 23:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 28 14.31 450 180 0.18 / 1390.88 2 2
2 12 1157.00 3 10.89 1999 65 0.25 / 1390.95 2 2
3 12 1931.08 90 8.32 3079 2306 2.55 / 1393.25 2 2
4 7 1921.96 25 9.44 3100 732 3.28 / 1393.98 2 2
5 13 1147.72 38 12.31 2022 946 4.23 / 1394.93 2 2
6 13 178.84 38 14.00 580 309 4.54 / 1395.24 2 2
7 8 -0.16 180 14.38 286 740 5.28 / 1395.98 2 2
Average= 4.97 (KJ/cycle)

Cycle 279 GMT 25/ 9/2022 19:26:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 29 14.22 453 187 0.19 / 1386.22 2 2
2 3 957.84 -1 14.22 453 0 0.00 / 1386.22 2 2
3 3 1024.44 1 11.10 1830 20 0.21 / 1386.24 2 2
4 12 1194.08 90 4.74 1803 769 0.98 / 1387.01 2 2
5 7 1204.72 25 8.87 2022 448 1.42 / 1387.45 2 2
6 13 1291.88 38 9.96 2200 833 2.26 / 1388.29 2 2
7 13 1182.84 38 10.93 2049 851 3.11 / 1389.14 2 2
8 13 629.16 38 12.76 1280 621 3.73 / 1389.76 2 2
9 13 44.04 38 14.21 363 196 3.93 / 1389.95 2 2
10 8 -0.20 180 14.33 289 745 4.67 / 1390.70 2 4
Average= 4.97 (KJ/cycle)

Cycle 278 GMT 16/ 9/2022 0: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 27 14.24 441 170 0.17 / 1381.95 2 2
2 12 1187.36 90 4.86 1894 828 1.00 / 1382.78 2 2
3 7 1197.64 25 9.03 2024 457 1.45 / 1383.23 2 2
4 13 1218.56 38 10.35 2102 827 2.28 / 1384.06 2 2
5 13 1067.40 38 11.29 1890 811 3.09 / 1384.87 2 2
6 13 308.12 38 13.55 805 414 3.51 / 1385.28 2 2
7 8 -0.12 180 14.32 289 745 4.25 / 1386.03 2 2
Average= 4.97 (KJ/cycle)

Cycle 277 GMT 6/ 9/2022 4:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 27 14.33 427 165 0.17 / 1378.33 2 2
2 12 1163.52 90 6.25 1904 1071 1.24 / 1379.40 2 2
3 7 1167.76 25 9.38 1984 465 1.70 / 1379.87 2 2
4 13 1027.60 38 11.37 1826 789 2.49 / 1380.66 2 2
5 13 289.96 38 13.61 762 394 2.88 / 1381.05 2 2
6 8 -0.12 180 14.36 281 726 3.61 / 1381.78 2 2
Average= 4.97 (KJ/cycle)

Cycle 276 GMT 27/ 8/2022 10: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 28 14.27 448 179 0.18 / 1373.16 2 2
2 12 1154.96 3 10.78 2000 65 0.24 / 1373.22 2 2
3 12 1929.32 90 8.20 3091 2281 2.52 / 1375.50 2 2
4 7 1920.28 25 9.63 3100 746 3.27 / 1376.25 2 2
5 13 988.36 38 12.66 1811 871 4.14 / 1377.12 2 2
6 13 178.88 38 14.02 586 312 4.45 / 1377.43 2 2
7 8 -0.08 180 14.39 283 733 5.19 / 1378.17 2 2
Average= 4.98 (KJ/cycle)

Cycle 275 GMT 26/ 8/2022 5:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 26 14.28 438 163 0.16 / 1368.40 2 2
2 3 1069.32 3 11.58 1889 66 0.23 / 1368.47 2 2
3 12 1192.48 90 4.75 1846 789 1.02 / 1369.26 2 2
4 7 1203.88 25 9.05 2036 461 1.48 / 1369.72 2 2
5 13 1297.04 38 10.33 2202 864 2.34 / 1370.58 2 2
6 13 1170.40 38 11.09 2046 862 3.20 / 1371.45 2 2
7 13 606.96 38 12.91 1249 613 3.82 / 1372.06 2 2
8 13 34.48 38 14.24 336 182 4.00 / 1372.24 2 2
9 8 -0.20 180 14.36 286 739 4.74 / 1372.98 2 4
Average= 4.97 (KJ/cycle)

Cycle 274 GMT 16/ 8/2022 10:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 27 14.26 432 166 0.17 / 1364.26 2 2
2 12 1179.92 90 4.92 1893 838 1.00 / 1365.10 2 2
3 7 1192.32 25 9.08 2008 456 1.46 / 1365.55 2 2
4 13 1166.56 38 10.69 2006 815 2.28 / 1366.37 2 2
5 13 1014.32 38 11.48 1811 790 3.07 / 1367.16 2 2
6 13 225.16 38 13.78 670 351 3.42 / 1367.51 2 2
7 8 -0.04 180 14.35 283 731 4.15 / 1368.24 2 2
Average= 4.98 (KJ/cycle)

Cycle 273 GMT 6/ 8/2022 15:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 27 14.30 419 162 0.16 / 1360.48 2 2
2 12 1169.00 90 6.26 1913 1078 1.24 / 1361.56 2 2
3 7 1176.72 25 9.47 2004 474 1.71 / 1362.03 2 2
4 13 1042.52 38 11.43 1857 807 2.52 / 1362.84 2 2
5 13 454.88 38 13.23 1030 518 3.04 / 1363.36 2 2
6 8 -0.20 180 14.34 285 736 3.77 / 1364.09 2 2
Average= 4.98 (KJ/cycle)

Cycle 272 GMT 27/ 7/2022 20:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 26 14.26 439 163 0.16 / 1355.25 2 2
2 3 1037.08 1 11.40 1848 21 0.18 / 1355.27 2 2
3 3 1013.12 1 10.62 1823 19 0.20 / 1355.29 2 2
4 12 1174.24 3 10.60 2046 65 0.27 / 1355.36 2 2
5 12 1930.76 90 8.11 3073 2243 2.51 / 1357.60 2 2
6 7 1921.60 25 9.63 3076 741 3.25 / 1358.34 2 2
7 13 1131.36 38 12.48 2006 951 4.20 / 1359.29 2 2
8 13 167.16 38 14.05 555 296 4.50 / 1359.59 2 2
9 8 0.12 180 14.37 283 732 5.23 / 1360.32 2 2
Average= 4.98 (KJ/cycle)

Cycle 271 GMT 26/ 7/2022 16:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 14.27 442 183 0.18 / 1350.82 2 2
2 3 902.28 -1 14.27 442 0 0.00 / 1350.82 2 2
3 12 1171.32 90 4.73 1780 758 0.94 / 1351.57 2 2
4 7 1183.12 25 8.93 2003 447 1.39 / 1352.02 2 2
5 13 1283.72 38 10.28 2175 850 2.24 / 1352.87 2 2
6 13 1158.32 38 11.13 2014 852 3.09 / 1353.72 2 2
7 13 596.28 38 12.95 1238 609 3.70 / 1354.33 2 2
8 8 0.64 180 14.34 293 756 4.45 / 1355.09 2 2
Average= 4.98 (KJ/cycle)

Cycle 270 GMT 16/ 7/2022 21:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 14.26 441 170 0.17 / 1346.69 2 2
2 12 1158.40 90 4.98 1867 837 1.01 / 1347.53 2 2
3 7 1169.16 25 9.11 1976 450 1.46 / 1347.98 2 2
4 13 1137.64 38 10.80 1984 814 2.27 / 1348.79 2 2
5 13 978.84 38 11.60 1775 782 3.05 / 1349.58 2 2
6 13 184.52 38 13.89 590 311 3.36 / 1349.89 2 2
7 8 -0.20 180 14.34 289 746 4.11 / 1350.63 2 2
Average= 4.98 (KJ/cycle)

Cycle 269 GMT 7/ 7/2022 2:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 14.30 431 166 0.17 / 1342.81 2 2
2 12 1168.20 90 6.24 1918 1077 1.24 / 1343.89 2 2
3 7 1171.80 25 9.55 2018 482 1.73 / 1344.37 2 2
4 13 1039.28 38 11.54 1854 813 2.54 / 1345.18 2 2
5 13 292.36 38 13.67 771 401 2.94 / 1345.58 2 2
6 13 6.56 38 14.26 309 167 3.11 / 1345.75 2 2
7 8 -0.16 180 14.33 299 771 3.88 / 1346.52 2 7
Average= 4.99 (KJ/cycle)

Cycle 268 GMT 27/ 6/2022 7:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 14.25 434 173 0.17 / 1337.46 2 2
2 3 941.80 -1 14.25 434 0 0.00 / 1337.46 2 2
3 3 1028.08 1 11.14 1849 21 0.19 / 1337.48 2 2
4 12 1181.76 3 10.89 2038 67 0.26 / 1337.55 2 2
5 12 1933.40 90 8.14 3101 2272 2.53 / 1339.82 2 2
6 7 1924.88 25 9.84 3106 764 3.30 / 1340.58 2 2
7 13 1180.80 38 12.47 2095 993 4.29 / 1341.58 2 2
8 13 176.24 38 14.00 581 309 4.60 / 1341.89 2 2
9 8 -0.32 180 14.35 294 759 5.36 / 1342.65 2 2
Average= 4.99 (KJ/cycle)

Cycle 267 GMT 26/ 6/2022 3:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 25 14.25 426 152 0.15 / 1333.24 2 2
2 10 1013.04 4 12.03 1830 88 0.24 / 1333.33 2 2
3 12 1148.40 90 4.89 1833 807 1.05 / 1334.13 2 2
4 7 1159.04 25 9.38 1973 463 1.51 / 1334.60 2 2
5 13 1216.00 38 10.86 2100 867 2.38 / 1335.46 2 2
6 13 909.24 38 12.19 1685 781 3.16 / 1336.24 2 2
7 13 177.80 38 13.95 576 305 3.46 / 1336.55 2 2
8 8 -0.08 180 14.35 286 739 4.20 / 1337.29 2 2
Average= 4.99 (KJ/cycle)

Cycle 266 GMT 16/ 6/2022 8:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 26 14.28 440 163 0.16 / 1328.89 2 2
2 3 1023.76 1 11.30 1820 21 0.18 / 1328.91 2 2
3 12 1196.80 90 4.78 1854 798 0.98 / 1329.71 2 2
4 7 1207.52 25 9.11 2046 466 1.45 / 1330.18 2 2
5 13 1266.56 38 10.60 2155 868 2.32 / 1331.04 2 2
6 13 1119.60 38 11.45 1966 855 3.17 / 1331.90 2 2
7 13 364.84 38 13.56 884 456 3.63 / 1332.35 2 2
8 8 0.00 180 14.33 284 733 4.36 / 1333.09 2 2
Average= 4.99 (KJ/cycle)

Cycle 265 GMT 6/ 6/2022 13: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 28 14.24 427 170 0.17 / 1324.80 2 2
2 3 953.04 -1 14.24 427 0 0.00 / 1324.80 2 2
3 3 1027.84 1 11.13 1824 20 0.19 / 1324.82 2 2
4 12 1190.92 90 6.23 1939 1087 1.28 / 1325.91 2 2
5 7 1197.20 25 9.61 2041 490 1.77 / 1326.40 2 2
6 13 1067.76 38 11.62 1898 838 2.61 / 1327.24 2 2
7 13 496.24 38 13.27 1082 546 3.15 / 1327.78 2 2
8 13 44.76 38 14.18 365 197 3.35 / 1327.98 2 2
9 8 -0.44 180 14.32 290 748 4.10 / 1328.73 2 8
Average= 5.00 (KJ/cycle)

Cycle 264 GMT 27/ 5/2022 18:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 28 14.24 452 180 0.18 / 1319.52 2 2
2 12 1176.68 3 10.89 2032 66 0.25 / 1319.59 2 2
3 12 1923.32 90 8.20 3079 2272 2.52 / 1321.86 2 2
4 7 1914.60 25 9.80 3122 765 3.28 / 1322.63 2 2
5 13 1134.04 38 12.57 2035 972 4.26 / 1323.60 2 2
6 13 166.40 38 14.02 565 301 4.56 / 1323.90 2 2
7 8 -0.28 180 14.36 284 734 5.29 / 1324.63 2 3
Average= 5.00 (KJ/cycle)

Cycle 263 GMT 26/ 5/2022 14:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 27 14.25 433 167 0.17 / 1315.03 2 2
2 3 953.72 -1 14.25 433 0 0.00 / 1315.03 2 2
3 3 1023.84 1 10.97 1829 20 0.19 / 1315.05 2 2
4 12 1196.20 90 4.74 1790 764 0.95 / 1315.81 2 2
5 7 1208.56 25 9.25 2045 473 1.42 / 1316.29 2 2
6 13 1301.00 38 10.67 2243 909 2.33 / 1317.20 2 2
7 13 1168.16 38 11.42 2054 891 3.22 / 1318.09 2 2
8 13 418.12 38 13.49 976 500 3.72 / 1318.59 2 2
9 8 0.72 180 14.33 292 753 4.48 / 1319.34 2 2
Average= 5.00 (KJ/cycle)

Cycle 262 GMT 16/ 5/2022 18:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 26 14.27 454 168 0.17 / 1310.41 2 2
2 10 1023.88 4 12.09 1840 89 0.26 / 1310.50 2 2
3 3 952.96 -1 12.09 1840 0 0.09 / 1310.50 2 2
4 3 1031.80 1 11.29 1831 21 0.28 / 1310.52 2 2
5 12 1194.12 90 4.92 1856 822 1.10 / 1311.34 2 2
6 7 1204.56 25 9.20 2039 469 1.57 / 1311.81 2 2
7 13 1242.04 38 10.81 2136 877 2.45 / 1312.69 2 2
8 13 1094.80 38 11.57 1949 857 3.30 / 1313.54 2 2
9 13 291.84 38 13.70 786 409 3.71 / 1313.95 2 2
10 13 3.96 38 14.27 300 163 3.88 / 1314.11 2 2
11 8 -0.12 180 14.31 291 750 4.62 / 1314.86 2 8
Average= 5.00 (KJ/cycle)

Cycle 261 GMT 6/ 5/2022 23:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 29 14.28 420 174 0.17 / 1306.32 2 2
2 3 923.92 -1 14.28 420 0 0.00 / 1306.32 2 2
3 12 1186.60 90 6.20 1923 1073 1.25 / 1307.40 2 2
4 7 1192.60 25 9.54 2060 491 1.74 / 1307.89 2 2
5 13 1061.88 38 11.55 1895 832 2.57 / 1308.72 2 2
6 13 499.32 38 13.27 1101 555 3.13 / 1309.27 2 2
7 13 49.80 38 14.15 376 202 3.33 / 1309.48 2 2
8 8 -0.36 180 14.31 296 762 4.09 / 1310.24 2 6
Average= 5.00 (KJ/cycle)

Cycle 260 GMT 27/ 4/2022 4:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 14.25 436 168 0.17 / 1301.07 2 2
2 3 1029.68 1 11.03 1843 20 0.19 / 1301.09 2 2
3 12 1179.32 3 10.56 2043 65 0.25 / 1301.16 2 2
4 12 1925.48 90 7.98 3075 2208 2.46 / 1303.37 2 2
5 7 1915.84 25 9.82 3124 767 3.23 / 1304.13 2 2
6 13 1139.36 38 12.57 2043 976 4.20 / 1305.11 2 2
7 13 165.40 38 14.01 558 297 4.50 / 1305.41 2 2
8 8 -0.24 180 14.36 287 742 5.24 / 1306.15 2 2
Average= 5.00 (KJ/cycle)

Cycle 259 GMT 26/ 4/2022 0:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 14.17 440 168 0.17 / 1296.57 2 2
2 12 1180.88 90 4.72 1714 728 0.90 / 1297.30 2 2
3 7 1191.72 25 8.99 2018 454 1.35 / 1297.75 2 2
4 13 1279.08 38 10.60 2177 877 2.23 / 1298.63 2 2
5 13 1157.48 38 11.32 2026 872 3.10 / 1299.50 2 2
6 13 439.36 38 13.44 1000 511 3.61 / 1300.01 2 2
7 13 8.60 38 14.24 293 159 3.77 / 1300.17 2 2
8 8 -0.20 180 14.32 287 740 4.51 / 1300.91 2 4
Average= 5.00 (KJ/cycle)

Cycle 258 GMT 16/ 4/2022 5:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.22 440 181 0.18 / 1292.37 2 2
2 12 1138.88 90 4.84 1769 771 0.95 / 1293.15 2 2
3 7 1149.72 25 9.13 1949 445 1.40 / 1293.59 2 2
4 13 1203.84 38 10.74 2082 850 2.25 / 1294.44 2 2
5 13 1046.40 38 11.61 1872 826 3.07 / 1295.27 2 2
6 13 278.88 38 13.72 746 389 3.46 / 1295.65 2 2
7 8 -0.24 180 14.31 289 744 4.21 / 1296.40 2 2
Average= 5.01 (KJ/cycle)

Cycle 257 GMT 6/ 4/2022 10: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 29 14.28 445 184 0.18 / 1288.70 2 2
2 12 1161.92 90 6.38 1895 1088 1.27 / 1289.78 2 2
3 7 1168.12 25 9.69 1985 481 1.75 / 1290.27 2 2
4 13 1025.72 38 11.73 1826 814 2.57 / 1291.08 2 2
5 13 270.56 38 13.72 733 382 2.95 / 1291.46 2 2
6 8 -0.32 180 14.32 284 732 3.68 / 1292.19 2 2
Average= 5.01 (KJ/cycle)

Cycle 256 GMT 27/ 3/2022 15:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 27 14.24 434 167 0.17 / 1283.41 2 2
2 12 1177.44 3 10.49 2023 64 0.23 / 1283.47 2 2
3 12 1920.56 90 7.94 3096 2212 2.44 / 1285.68 2 2
4 7 1912.20 25 9.96 3101 772 3.22 / 1286.45 2 2
5 13 1165.08 38 12.58 2061 985 4.20 / 1287.44 2 2
6 13 190.40 38 13.96 604 320 4.52 / 1287.76 2 2
7 8 -0.28 180 14.35 291 752 5.27 / 1288.51 2 2
Average= 5.01 (KJ/cycle)

Cycle 255 GMT 26/ 3/2022 11: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 27 14.23 437 168 0.17 / 1278.71 2 2
2 12 1181.04 90 4.73 1741 741 0.91 / 1279.45 2 2
3 7 1194.04 25 9.21 2031 468 1.38 / 1279.92 2 2
4 13 1274.04 38 10.84 2184 900 2.28 / 1280.82 2 2
5 13 1121.52 38 11.66 1973 874 3.15 / 1281.69 2 2
6 13 546.60 38 13.24 1165 586 3.74 / 1282.28 2 2
7 13 55.92 38 14.15 379 204 3.94 / 1282.48 2 2
8 8 -0.24 180 14.29 295 759 4.70 / 1283.24 2 6
Average= 5.01 (KJ/cycle)

Cycle 254 GMT 16/ 3/2022 16: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 27 14.22 453 174 0.17 / 1274.40 2 2
2 3 1026.84 1 11.05 1834 20 0.19 / 1274.42 2 2
3 12 1176.12 90 4.82 1800 781 0.98 / 1275.20 2 2
4 7 1186.64 25 9.19 2018 464 1.44 / 1275.67 2 2
5 13 1234.92 38 10.94 2136 888 2.33 / 1276.56 2 2
6 13 1077.00 38 11.77 1917 857 3.18 / 1277.41 2 2
7 13 265.80 38 13.76 733 383 3.57 / 1277.80 2 2
8 8 -0.16 180 14.30 289 744 4.31 / 1278.54 2 2
Average= 5.01 (KJ/cycle)

Cycle 253 GMT 6/ 3/2022 20:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 27 14.26 427 164 0.16 / 1270.67 2 2
2 12 1167.68 90 6.49 1903 1112 1.28 / 1271.78 2 2
3 7 1172.32 25 9.77 2005 490 1.77 / 1272.27 2 2
4 13 1032.28 38 11.77 1835 821 2.59 / 1273.09 2 2
5 13 280.68 38 13.69 760 395 2.98 / 1273.49 2 2
6 8 0.16 180 14.29 288 741 3.72 / 1274.23 2 2
Average= 5.02 (KJ/cycle)

Cycle 252 GMT 25/ 2/2022 2:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 26 14.18 434 160 0.16 / 1265.41 2 2
2 12 1161.76 3 10.32 2008 62 0.22 / 1265.47 2 2
3 12 1924.92 90 7.95 3068 2195 2.42 / 1267.66 2 2
4 7 1916.52 25 9.97 3107 774 3.19 / 1268.44 2 2
5 13 1169.28 38 12.55 2094 999 4.19 / 1269.44 2 2
6 13 176.76 38 13.97 595 316 4.51 / 1269.75 2 2
7 8 -0.12 180 14.34 292 754 5.26 / 1270.51 2 3
Average= 5.02 (KJ/cycle)

Cycle 251 GMT 23/ 2/2022 22: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 14.21 423 162 0.16 / 1260.90 2 2
2 12 1165.28 90 4.73 1750 745 0.91 / 1261.64 2 2
3 7 1176.48 25 9.31 2006 467 1.37 / 1262.11 2 2
4 13 1259.88 38 10.94 2148 893 2.27 / 1263.00 2 2
5 13 1126.56 38 11.77 1972 882 3.15 / 1263.89 2 2
6 13 352.52 38 13.59 867 448 3.60 / 1264.33 2 2
7 13 30.64 38 14.19 333 180 3.78 / 1264.51 2 2
8 8 -0.28 180 14.30 285 734 4.51 / 1265.25 2 9
Average= 5.02 (KJ/cycle)

Cycle 250 GMT 14/ 2/2022 2:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 27 14.19 436 167 0.17 / 1256.31 2 2
2 12 1178.88 90 4.73 1777 756 0.92 / 1257.07 2 2
3 7 1188.64 25 9.13 2013 459 1.38 / 1257.53 2 2
4 13 1268.52 38 10.77 2182 893 2.28 / 1258.42 2 2
5 13 1144.76 38 11.65 2007 888 3.16 / 1259.31 2 2
6 13 423.12 38 13.45 980 501 3.67 / 1259.81 2 2
7 13 41.04 38 14.18 345 186 3.85 / 1260.00 2 2
8 8 -0.32 180 14.29 288 741 4.59 / 1260.74 2 5
Average= 5.02 (KJ/cycle)

Cycle 249 GMT 4/ 2/2022 7:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 27 14.25 425 164 0.16 / 1252.57 2 2
2 12 1174.28 90 6.38 1922 1104 1.27 / 1253.67 2 2
3 7 1181.44 25 9.78 2020 494 1.76 / 1254.16 2 2
4 13 1049.92 38 11.73 1875 836 2.60 / 1255.00 2 2
5 13 295.08 38 13.65 779 404 3.00 / 1255.40 2 2
6 8 -0.12 180 14.30 288 741 3.74 / 1256.14 2 2
Average= 5.02 (KJ/cycle)

Cycle 248 GMT 25/ 1/2022 12:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.21 431 184 0.18 / 1247.34 2 2
2 3 888.40 -1 14.21 431 0 0.00 / 1247.34 2 2
3 12 1146.24 3 10.54 1981 63 0.25 / 1247.40 2 2
4 12 1920.60 90 7.84 3097 2185 2.43 / 1249.59 2 2
5 7 1911.48 25 10.01 3114 779 3.21 / 1250.36 2 2
6 13 1171.36 38 12.59 2076 993 4.20 / 1251.36 2 2
7 13 178.68 38 13.97 581 308 4.51 / 1251.67 2 2
8 8 -0.20 180 14.35 285 736 5.25 / 1252.40 2 2
Average= 5.03 (KJ/cycle)

Cycle 247 GMT 24/ 1/2022 8:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 14.22 435 167 0.17 / 1242.96 2 2
2 12 1150.56 90 4.72 1737 738 0.90 / 1243.69 2 2
3 7 1161.64 25 9.33 1973 460 1.37 / 1244.15 2 2
4 13 1258.80 38 11.04 2154 904 2.27 / 1245.06 2 2
5 13 1122.88 38 11.88 1974 891 3.16 / 1245.95 2 2
6 13 353.52 38 13.59 868 448 3.61 / 1246.40 2 2
7 8 -0.16 180 14.29 294 756 4.36 / 1247.15 2 2
Average= 5.03 (KJ/cycle)

Cycle 246 GMT 14/ 1/2022 13: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 27 14.18 436 167 0.17 / 1238.60 2 2
2 12 1170.92 90 4.85 1805 788 0.95 / 1239.39 2 2
3 7 1182.84 25 9.30 2004 466 1.42 / 1239.86 2 2
4 13 1233.36 38 11.09 2141 902 2.32 / 1240.76 2 2
5 13 1081.28 38 11.93 1940 879 3.20 / 1241.64 2 2
6 13 293.48 38 13.69 777 404 3.61 / 1242.04 2 2
7 8 -0.24 180 14.30 290 746 4.35 / 1242.79 2 2
Average= 5.03 (KJ/cycle)

Cycle 245 GMT 4/ 1/2022 17:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.26 430 166 0.17 / 1234.83 2 2
2 12 1161.40 90 6.81 1907 1169 1.33 / 1236.00 2 2
3 7 1166.04 25 10.01 2005 502 1.84 / 1236.50 2 2
4 13 1010.96 38 12.00 1822 831 2.67 / 1237.34 2 2
5 13 229.72 38 13.79 670 351 3.02 / 1237.69 2 2
6 8 -0.16 180 14.27 292 750 3.77 / 1238.44 2 2
Average= 5.03 (KJ/cycle)

Cycle 244 GMT 25/12/2021 23:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 25 14.19 447 159 0.16 / 1229.49 2 2
2 10 1011.04 4 11.93 1826 87 0.25 / 1229.57 2 2
3 12 1164.16 3 10.59 2015 64 0.31 / 1229.64 2 2
4 12 1931.60 90 8.35 3081 2315 2.63 / 1231.95 2 2
5 7 1922.40 25 10.12 3095 783 3.41 / 1232.74 2 2
6 13 938.48 38 12.90 1760 863 4.27 / 1233.60 2 2
7 13 165.04 38 13.97 584 310 4.58 / 1233.91 2 2
8 8 -0.28 180 14.33 294 758 5.34 / 1234.67 2 2
Average= 5.04 (KJ/cycle)

Cycle 243 GMT 24/12/2021 19:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 14.17 434 160 0.16 / 1225.17 2 2
2 3 1017.08 1 10.51 1817 19 0.18 / 1225.19 2 2
3 12 1186.80 90 4.79 1800 776 0.95 / 1225.96 2 2
4 7 1197.24 25 9.56 2042 488 1.44 / 1226.45 2 2
5 13 1235.24 38 11.45 2155 938 2.38 / 1227.39 2 2
6 13 1087.24 38 12.20 1949 904 3.28 / 1228.29 2 2
7 13 160.20 38 13.95 553 293 3.58 / 1228.59 2 2
8 8 -0.20 180 14.30 289 744 4.32 / 1229.33 2 2
Average= 5.04 (KJ/cycle)

Cycle 242 GMT 14/12/2021 23:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 26 14.20 419 155 0.15 / 1220.69 2 2
2 3 1028.36 1 10.86 1837 20 0.17 / 1220.71 2 2
3 12 1187.04 90 4.87 1844 808 0.98 / 1221.52 2 2
4 7 1199.56 25 9.49 2040 484 1.47 / 1222.00 2 2
5 13 1244.12 38 11.34 2146 925 2.39 / 1222.93 2 2
6 13 1086.72 38 12.17 1936 895 3.29 / 1223.82 2 2
7 13 300.08 38 13.69 797 415 3.70 / 1224.24 2 2
8 8 -0.28 180 14.28 300 771 4.47 / 1225.01 2 2
Average= 5.04 (KJ/cycle)

Cycle 241 GMT 5/12/2021 4:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 28 14.20 431 171 0.17 / 1216.87 2 2
2 3 940.64 -1 14.20 431 0 0.00 / 1216.87 2 2
3 3 1025.04 1 10.61 1820 19 0.19 / 1216.89 2 2
4 12 1175.96 90 6.66 1923 1153 1.34 / 1218.05 2 2
5 7 1181.48 25 10.06 2019 508 1.85 / 1218.55 2 2
6 13 1057.12 38 12.04 1871 856 2.71 / 1219.41 2 2
7 13 268.80 38 13.73 747 390 3.10 / 1219.80 2 2
8 8 -0.28 180 14.28 286 735 3.83 / 1220.54 2 2
Average= 5.04 (KJ/cycle)

Cycle 240 GMT 25/11/2021 10: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 14.25 421 168 0.17 / 1211.58 2 2
2 3 928.32 -1 14.25 421 0 0.00 / 1211.58 2 2
3 12 1183.68 3 10.43 2023 63 0.23 / 1211.64 2 2
4 12 1922.12 90 8.28 3071 2289 2.52 / 1213.93 2 2
5 7 1913.12 25 10.21 3081 786 3.31 / 1214.71 2 2
6 13 1122.20 38 12.73 1996 966 4.27 / 1215.68 2 2
7 13 139.36 38 14.02 531 283 4.55 / 1215.96 2 2
8 8 -0.24 180 14.34 287 741 5.30 / 1216.70 2 2
Average= 5.05 (KJ/cycle)

Cycle 239 GMT 24/11/2021 6: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 26 14.20 428 158 0.16 / 1206.96 2 2
2 12 1197.00 90 4.73 1753 746 0.90 / 1207.71 2 2
3 7 1208.60 25 9.21 2050 472 1.38 / 1208.18 2 2
4 13 1289.88 38 11.16 2198 932 2.31 / 1209.11 2 2
5 13 1143.28 38 12.05 2001 916 3.22 / 1210.03 2 2
6 13 367.84 38 13.60 887 458 3.68 / 1210.49 2 2
7 13 27.44 38 14.19 332 179 3.86 / 1210.66 2 2
8 8 -0.20 180 14.29 289 743 4.61 / 1211.41 2 7
Average= 5.05 (KJ/cycle)

Cycle 238 GMT 14/11/2021 10:42:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 14.23 437 174 0.17 / 1202.75 2 2
2 12 1159.60 90 5.01 1818 820 0.99 / 1203.57 2 2
3 7 1169.72 25 9.52 1988 473 1.47 / 1204.04 2 2
4 13 1148.88 38 11.59 2015 887 2.35 / 1204.93 2 2
5 13 988.28 38 12.35 1799 844 3.20 / 1205.77 2 2
6 13 163.24 38 13.93 555 294 3.49 / 1206.06 2 2
7 8 0.12 180 14.27 287 737 4.23 / 1206.80 2 4
Average= 5.05 (KJ/cycle)

Cycle 237 GMT 4/11/2021 15:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 25 14.16 439 155 0.16 / 1198.79 2 2
2 10 1004.80 5 12.28 1824 112 0.27 / 1198.90 2 2
3 3 945.60 -1 12.28 1824 0 0.11 / 1198.90 2 2
4 3 1027.68 1 10.81 1837 20 0.29 / 1198.92 2 2
5 12 1185.40 90 6.69 1933 1164 1.45 / 1200.08 2 2
6 7 1188.76 25 10.14 2046 519 1.97 / 1200.60 2 2
7 13 1038.64 38 12.22 1869 868 2.84 / 1201.47 2 2
8 13 249.60 38 13.78 717 375 3.21 / 1201.84 2 2
9 8 -0.16 180 14.30 283 728 3.94 / 1202.57 2 2
Average= 5.05 (KJ/cycle)

Cycle 236 GMT 25/10/2021 21:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 14.12 458 175 0.17 / 1193.51 2 2
2 3 1012.32 1 9.96 1839 18 0.19 / 1193.52 2 2
3 3 1012.96 1 9.22 1801 17 0.21 / 1193.54 2 2
4 12 1172.00 3 10.60 2026 64 0.27 / 1193.60 2 2
5 12 1929.48 90 8.38 3101 2339 2.61 / 1195.94 2 2
6 7 1919.84 25 10.20 3101 791 3.40 / 1196.73 2 2
7 13 956.52 38 12.93 1767 868 4.27 / 1197.60 2 2
8 13 158.96 38 13.99 547 291 4.56 / 1197.89 2 2
9 8 -0.28 180 14.33 286 738 5.30 / 1198.63 2 2
Average= 5.06 (KJ/cycle)

Cycle 235 GMT 24/10/2021 17:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 14.18 447 177 0.18 / 1188.99 2 2
2 3 957.64 -1 14.18 447 0 0.00 / 1188.99 2 2
3 3 1040.80 2 10.69 1842 39 0.22 / 1189.03 2 2
4 12 1191.28 90 4.95 1853 826 1.04 / 1189.85 2 2
5 7 1203.40 25 9.76 2053 501 1.54 / 1190.35 2 2
6 13 1233.52 38 11.67 2151 954 2.50 / 1191.31 2 2
7 13 1062.88 38 12.40 1923 906 3.40 / 1192.21 2 2
8 13 228.28 38 13.82 675 354 3.76 / 1192.57 2 2
9 8 -0.24 180 14.27 297 763 4.52 / 1193.33 2 2
Average= 5.06 (KJ/cycle)

Cycle 234 GMT 14/10/2021 22:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 14.16 438 174 0.17 / 1184.61 2 2
2 3 949.24 -1 14.16 438 0 0.00 / 1184.61 2 2
3 3 1019.04 1 10.21 1784 18 0.19 / 1184.63 2 2
4 12 1200.68 90 5.01 1877 846 1.04 / 1185.48 2 2
5 7 1210.88 25 9.63 2060 496 1.53 / 1185.97 2 2
6 13 1200.68 38 11.63 2102 929 2.46 / 1186.90 2 2
7 13 1035.40 38 12.40 1871 882 3.34 / 1187.78 2 2
8 13 116.80 38 14.01 488 260 3.60 / 1188.04 2 2
9 8 -0.12 180 14.28 298 766 4.37 / 1188.81 2 2
Average= 5.06 (KJ/cycle)

Cycle 233 GMT 5/10/2021 3:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 27 14.15 451 172 0.17 / 1180.73 2 2
2 3 1025.48 1 11.01 1822 20 0.19 / 1180.75 2 2
3 12 1181.40 90 6.75 1954 1187 1.38 / 1181.94 2 2
4 7 1184.40 25 10.18 2049 521 1.90 / 1182.46 2 2
5 13 1022.12 38 12.25 1859 865 2.77 / 1183.33 2 2
6 13 217.68 38 13.81 660 346 3.11 / 1183.67 2 2
7 8 -0.24 180 14.26 298 765 3.88 / 1184.44 2 2
Average= 5.06 (KJ/cycle)

Cycle 232 GMT 25/ 9/2021 8:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 26 14.22 441 163 0.16 / 1175.48 2 2
2 3 1022.44 1 10.78 1836 20 0.18 / 1175.50 2 2
3 12 1171.12 3 10.45 2013 63 0.25 / 1175.56 2 2
4 12 1930.76 90 8.18 3115 2293 2.54 / 1177.86 2 2
5 7 1921.16 25 10.24 3106 795 3.33 / 1178.65 2 2
6 13 954.04 38 12.92 1772 870 4.20 / 1179.52 2 2
7 13 156.24 38 13.98 549 292 4.50 / 1179.81 2 2
8 8 0.40 180 14.33 290 748 5.24 / 1180.56 2 2
Average= 5.07 (KJ/cycle)

Cycle 231 GMT 24/ 9/2021 4:30:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 28 14.21 442 176 0.18 / 1171.28 2 2
2 12 1171.56 90 5.00 1827 822 1.00 / 1172.10 2 2
3 7 1182.76 25 9.69 2012 487 1.49 / 1172.59 2 2
4 13 1150.88 38 11.84 2008 903 2.39 / 1173.50 2 2
5 13 983.76 38 12.53 1783 849 3.24 / 1174.34 2 2
6 13 86.88 38 14.07 429 229 3.47 / 1174.57 2 2
7 8 -0.20 180 14.30 289 744 4.21 / 1175.32 2 2
Average= 5.07 (KJ/cycle)

Cycle 230 GMT 14/ 9/2021 9:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 25 14.09 444 156 0.16 / 1167.16 2 2
2 3 1036.48 1 11.01 1843 20 0.18 / 1167.18 2 2
3 12 1177.16 90 5.25 1863 880 1.06 / 1168.06 2 2
4 7 1185.84 25 9.75 2036 496 1.55 / 1168.56 2 2
5 13 1114.36 38 11.97 1975 898 2.45 / 1169.46 2 2
6 13 764.36 38 12.99 1470 726 3.18 / 1170.18 2 2
7 13 65.64 38 14.13 380 204 3.38 / 1170.39 2 2
8 8 -0.12 180 14.31 279 719 4.10 / 1171.11 2 2
Average= 5.07 (KJ/cycle)

Cycle 229 GMT 4/ 9/2021 14:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 14.21 435 179 0.18 / 1163.33 2 2
2 3 907.96 -1 14.21 435 0 0.00 / 1163.33 2 2
3 12 1181.48 90 6.96 1958 1226 1.41 / 1164.56 2 2
4 7 1185.52 25 10.31 2047 528 1.93 / 1165.09 2 2
5 13 1017.00 38 12.37 1838 864 2.80 / 1165.95 2 2
6 13 195.32 38 13.85 611 322 3.12 / 1166.27 2 2
7 8 -0.20 180 14.28 286 735 3.85 / 1167.01 2 2
Average= 5.07 (KJ/cycle)

Cycle 228 GMT 25/ 8/2021 20:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 27 14.11 443 169 0.17 / 1157.92 2 2
2 3 954.52 -1 14.11 443 0 0.00 / 1157.92 2 2
3 3 1044.56 2 10.96 1838 40 0.21 / 1157.96 2 2
4 12 1175.88 3 10.54 2040 65 0.27 / 1158.03 2 2
5 12 1926.12 90 8.66 3081 2401 2.67 / 1160.43 2 2
6 7 1915.72 25 10.28 3122 802 3.48 / 1161.23 2 2
7 13 937.44 38 12.96 1745 859 4.34 / 1162.09 2 2
8 13 141.32 38 14.00 538 286 4.62 / 1162.37 2 2
9 8 -0.24 180 14.32 302 778 5.40 / 1163.15 2 2
Average= 5.08 (KJ/cycle)

Cycle 227 GMT 24/ 8/2021 16:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 26 14.15 437 161 0.16 / 1153.67 2 2
2 3 1050.44 2 11.22 1859 42 0.20 / 1153.71 2 2
3 3 1013.52 1 10.27 1811 19 0.22 / 1153.73 2 2
4 12 1196.64 90 5.28 1886 896 1.12 / 1154.62 2 2
5 7 1205.20 25 9.88 2061 509 1.63 / 1155.13 2 2
6 13 1121.04 38 12.10 1991 915 2.54 / 1156.05 2 2
7 13 770.48 38 13.02 1497 741 3.28 / 1156.79 2 2
8 13 61.76 38 14.11 388 208 3.49 / 1157.00 2 2
9 8 -0.20 180 14.29 293 754 4.24 / 1157.75 2 4
Average= 5.08 (KJ/cycle)

Cycle 226 GMT 14/ 8/2021 21:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 25 14.13 441 156 0.16 / 1149.43 2 2
2 3 1075.16 3 11.36 1894 65 0.22 / 1149.49 2 2
3 3 1015.64 1 10.70 1831 20 0.24 / 1149.51 2 2
4 12 1199.60 90 5.44 1901 931 1.17 / 1150.44 2 2
5 7 1208.52 25 9.89 2057 509 1.68 / 1150.95 2 2
6 13 1107.52 38 12.10 1961 902 2.58 / 1151.85 2 2
7 13 741.44 38 13.01 1453 718 3.30 / 1152.57 2 2
8 13 51.68 38 14.15 366 197 3.50 / 1152.77 2 2
9 8 -0.24 180 14.29 288 741 4.24 / 1153.51 2 4
Average= 5.08 (KJ/cycle)

Cycle 225 GMT 5/ 8/2021 3: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 14.19 426 169 0.17 / 1145.56 2 2
2 3 943.32 -1 14.19 426 0 0.00 / 1145.56 2 2
3 3 1021.88 1 10.85 1818 20 0.19 / 1145.58 2 2
4 12 1175.72 90 7.10 1937 1238 1.43 / 1146.81 2 2
5 7 1178.52 25 10.36 2021 523 1.95 / 1147.34 2 2
6 13 1021.44 38 12.43 1830 864 2.81 / 1148.20 2 2
7 13 194.64 38 13.84 623 328 3.14 / 1148.53 2 2
8 8 -0.24 180 14.28 288 740 3.88 / 1149.27 2 2
Average= 5.09 (KJ/cycle)

Cycle 224 GMT 26/ 7/2021 8:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 27 14.14 448 171 0.17 / 1140.22 2 2
2 12 1162.24 3 10.58 2004 64 0.23 / 1140.29 2 2
3 12 1918.56 90 8.51 3083 2361 2.60 / 1142.65 2 2
4 7 1908.48 25 10.29 3069 790 3.39 / 1143.44 2 2
5 13 1094.16 38 12.77 1968 955 4.34 / 1144.39 2 2
6 13 116.12 38 14.07 475 254 4.59 / 1144.64 2 2
7 8 -0.12 180 14.34 288 743 5.34 / 1145.39 2 2
Average= 5.09 (KJ/cycle)

Cycle 223 GMT 25/ 7/2021 4:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 14.20 430 171 0.17 / 1135.98 2 2
2 3 946.04 -1 14.20 430 0 0.00 / 1135.98 2 2
3 3 1029.48 1 10.78 1834 20 0.19 / 1136.00 2 2
4 12 1205.04 90 5.26 1909 904 1.09 / 1136.90 2 2
5 7 1215.24 25 9.85 2069 509 1.60 / 1137.41 2 2
6 13 1140.88 38 12.08 2009 922 2.53 / 1138.33 2 2
7 13 779.00 38 12.97 1512 745 3.27 / 1139.08 2 2
8 13 72.48 38 14.07 418 223 3.49 / 1139.30 2 2
9 8 -0.24 180 14.29 291 749 4.24 / 1140.05 2 2
Average= 5.09 (KJ/cycle)

Cycle 222 GMT 15/ 7/2021 9:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 14.20 454 181 0.18 / 1132.11 2 2
2 12 1179.04 90 5.77 1914 994 1.17 / 1133.10 2 2
3 7 1187.12 25 10.01 2038 510 1.68 / 1133.61 2 2
4 13 1073.00 38 12.16 1919 887 2.57 / 1134.50 2 2
5 13 513.04 38 13.34 1110 563 3.13 / 1135.06 2 2
6 8 -0.20 180 14.28 290 745 3.88 / 1135.81 2 2
Average= 5.09 (KJ/cycle)

Cycle 221 GMT 5/ 7/2021 15: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 25 14.16 452 160 0.16 / 1128.03 2 2
2 10 1002.44 5 12.44 1819 113 0.27 / 1128.14 2 2
3 3 956.76 -1 12.44 1819 0 0.11 / 1128.14 2 2
4 3 1021.84 1 10.92 1813 20 0.29 / 1128.16 2 2
5 12 1182.64 90 7.16 1962 1264 1.56 / 1129.43 2 2
6 7 1185.56 25 10.38 2039 529 2.09 / 1129.96 2 2
7 13 1031.04 38 12.40 1862 877 2.96 / 1130.84 2 2
8 13 224.08 38 13.79 663 347 3.31 / 1131.18 2 2
9 8 -0.28 180 14.27 290 745 4.06 / 1131.93 2 2
Average= 5.10 (KJ/cycle)

Cycle 220 GMT 25/ 6/2021 20:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 27 14.13 440 168 0.17 / 1122.78 2 2
2 12 1154.08 3 10.58 2001 64 0.23 / 1122.85 2 2
3 12 1928.60 90 8.10 3130 2282 2.51 / 1125.13 2 2
4 7 1919.64 25 10.19 3105 791 3.30 / 1125.92 2 2
5 13 964.20 38 12.91 1781 874 4.18 / 1126.79 2 2
6 13 182.04 38 13.92 606 321 4.50 / 1127.11 2 2
7 8 -0.24 180 14.33 294 758 5.26 / 1127.87 2 2
Average= 5.10 (KJ/cycle)

Cycle 219 GMT 24/ 6/2021 16:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 28 14.15 452 179 0.18 / 1118.89 2 2
2 12 1174.36 90 5.74 1912 988 1.17 / 1119.88 2 2
3 7 1181.20 25 10.02 2056 515 1.68 / 1120.40 2 2
4 13 1065.88 38 12.21 1923 892 2.57 / 1121.29 2 2
5 13 517.56 38 13.34 1118 567 3.14 / 1121.86 2 2
6 8 -0.20 180 14.29 295 759 3.90 / 1122.61 2 2
Average= 5.10 (KJ/cycle)

Cycle 218 GMT 14/ 6/2021 21:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.11 426 168 0.17 / 1114.87 2 2
2 3 930.16 -1 14.11 426 0 0.00 / 1114.87 2 2
3 3 1020.92 1 10.90 1833 20 0.19 / 1114.89 2 2
4 12 1211.36 90 5.75 1949 1009 1.20 / 1115.89 2 2
5 7 1218.48 25 10.00 2084 521 1.72 / 1116.42 2 2
6 13 1096.36 38 12.22 1944 903 2.62 / 1117.32 2 2
7 13 370.32 38 13.53 904 465 3.09 / 1117.78 2 2
8 13 32.12 38 14.16 342 184 3.27 / 1117.97 2 2
9 8 -0.24 180 14.28 291 748 4.02 / 1118.72 2 5
Average= 5.11 (KJ/cycle)

Cycle 217 GMT 5/ 6/2021 2:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 28 14.21 440 175 0.18 / 1111.16 2 2
2 12 1174.56 90 7.41 1962 1308 1.48 / 1112.47 2 2
3 7 1175.04 25 10.46 2019 528 2.01 / 1113.00 2 2
4 13 821.44 38 12.81 1563 761 2.77 / 1113.76 2 2
5 13 88.28 38 14.04 439 234 3.01 / 1113.99 2 2
6 8 -0.16 180 14.30 275 708 3.71 / 1114.70 2 4
Average= 5.11 (KJ/cycle)

Cycle 216 GMT 26/ 5/2021 8: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 27 14.16 433 166 0.17 / 1105.90 2 2
2 12 1147.84 3 10.60 1975 63 0.23 / 1105.96 2 2
3 12 1918.88 90 8.36 3079 2317 2.54 / 1108.28 2 2
4 7 1909.32 25 10.29 3076 791 3.34 / 1109.07 2 2
5 13 966.76 38 12.89 1785 874 4.21 / 1109.94 2 2
6 13 156.52 38 13.97 554 294 4.50 / 1110.24 2 2
7 8 0.28 180 14.33 290 748 5.25 / 1110.98 2 2
Average= 5.12 (KJ/cycle)

Cycle 215 GMT 25/ 5/2021 3:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 27 14.15 441 168 0.17 / 1102.16 2 2
2 3 1016.60 1 10.83 1809 20 0.19 / 1102.18 2 2
3 12 1168.88 90 5.97 1900 1021 1.21 / 1103.20 2 2
4 7 1174.76 25 10.14 2021 512 1.72 / 1103.71 2 2
5 13 1043.68 38 12.39 1867 879 2.60 / 1104.59 2 2
6 13 293.64 38 13.70 767 399 3.00 / 1104.99 2 2
7 8 -0.28 180 14.29 288 741 3.74 / 1105.73 2 2
Average= 5.12 (KJ/cycle)

Cycle 214 GMT 15/ 5/2021 9:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 25 14.18 441 156 0.16 / 1098.19 2 2
2 3 1059.16 2 11.55 1895 44 0.20 / 1098.24 2 2
3 3 1014.36 1 10.59 1845 20 0.22 / 1098.26 2 2
4 12 1203.60 90 6.08 1960 1073 1.29 / 1099.33 2 2
5 7 1210.32 25 10.10 2106 532 1.82 / 1099.86 2 2
6 13 1112.56 38 12.25 1977 920 2.74 / 1100.78 2 2
7 13 343.32 38 13.58 873 451 3.19 / 1101.23 2 2
8 8 -0.20 180 14.29 295 759 3.95 / 1101.99 2 2
Average= 5.13 (KJ/cycle)

Cycle 213 GMT 5/ 5/2021 14:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 14.24 430 171 0.17 / 1094.17 2 2
2 3 949.20 -1 14.24 430 0 0.00 / 1094.17 2 2
3 3 1018.40 1 11.15 1820 20 0.19 / 1094.19 2 2
4 12 1207.64 90 7.45 2007 1346 1.54 / 1095.53 2 2
5 7 1210.96 25 10.47 2085 546 2.08 / 1096.08 2 2
6 13 1043.28 38 12.44 1893 895 2.98 / 1096.98 2 2
7 13 184.72 38 13.86 592 312 3.29 / 1097.29 2 2
8 8 -0.36 180 14.26 292 750 4.04 / 1098.04 2 2
Average= 5.13 (KJ/cycle)

Cycle 212 GMT 25/ 4/2021 20: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 14.14 439 168 0.17 / 1088.99 2 2
2 12 1175.84 3 10.64 2040 65 0.23 / 1089.06 2 2
3 12 1897.76 90 8.57 3052 2354 2.59 / 1091.41 2 2
4 7 1885.92 25 10.27 3043 781 3.37 / 1092.20 2 2
5 13 904.48 38 12.96 1699 837 4.20 / 1093.03 2 2
6 13 72.76 38 14.16 404 217 4.42 / 1093.25 2 2
7 8 -0.20 180 14.33 290 748 5.17 / 1094.00 2 3
Average= 5.14 (KJ/cycle)

Cycle 211 GMT 24/ 4/2021 15:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 26 14.16 436 161 0.16 / 1084.98 2 2
2 3 1016.84 1 11.05 1820 20 0.18 / 1085.00 2 2
3 12 1197.60 90 5.96 1954 1048 1.23 / 1086.05 2 2
4 7 1205.04 25 10.11 2084 527 1.76 / 1086.57 2 2
5 13 1077.20 38 12.29 1933 903 2.66 / 1087.48 2 2
6 13 324.32 38 13.61 824 426 3.08 / 1087.90 2 2
7 13 25.84 38 14.16 333 179 3.26 / 1088.08 2 2
8 8 -0.32 180 14.29 290 746 4.01 / 1088.83 2 5
Average= 5.14 (KJ/cycle)

Cycle 210 GMT 14/ 4/2021 21:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 27 14.16 429 164 0.16 / 1081.16 2 2
2 12 1198.00 90 6.30 1958 1110 1.27 / 1082.27 2 2
3 7 1202.92 25 10.24 2069 530 1.80 / 1082.80 2 2
4 13 1039.96 38 12.37 1882 885 2.69 / 1083.69 2 2
5 13 267.88 38 13.68 744 387 3.08 / 1084.07 2 2
6 8 0.36 180 14.28 290 745 3.82 / 1084.82 2 2
Average= 5.14 (KJ/cycle)

Cycle 209 GMT 5/ 4/2021 2:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 25 14.19 415 147 0.15 / 1077.32 2 2
2 3 1046.76 2 11.83 1885 45 0.19 / 1077.37 2 2
3 12 1185.88 90 7.76 1975 1379 1.57 / 1078.75 2 2
4 7 1189.00 25 10.56 2036 538 2.11 / 1079.28 2 2
5 13 833.04 38 12.83 1570 765 2.87 / 1080.05 2 2
6 13 90.32 38 14.03 435 232 3.11 / 1080.28 2 2
7 8 -0.36 180 14.29 278 715 3.82 / 1081.00 2 3
Average= 5.15 (KJ/cycle)

Cycle 208 GMT 26/ 3/2021 7:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 25 14.13 428 151 0.15 / 1072.01 2 2
2 3 1057.28 2 11.49 1878 43 0.19 / 1072.05 2 2
3 12 1157.56 3 10.84 2015 66 0.26 / 1072.12 2 2
4 12 1899.84 90 8.50 3043 2328 2.59 / 1074.44 2 2
5 7 1889.44 25 10.26 3046 781 3.37 / 1075.23 2 2
6 13 1102.04 38 12.70 1987 959 4.33 / 1076.18 2 2
7 13 121.52 38 14.04 484 258 4.59 / 1076.44 2 2
8 8 -0.36 180 14.34 284 733 5.32 / 1077.18 2 3
Average= 5.15 (KJ/cycle)

Cycle 207 GMT 25/ 3/2021 4: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 14.22 435 186 0.19 / 1068.15 2 2
2 3 892.08 -1 14.22 435 0 0.00 / 1068.15 2 2
3 12 1146.48 90 6.30 1897 1076 1.26 / 1069.22 2 2
4 7 1152.88 25 10.23 1988 508 1.77 / 1069.73 2 2
5 13 1016.92 38 12.37 1837 864 2.63 / 1070.59 2 2
6 13 265.04 38 13.71 721 376 3.01 / 1070.97 2 2
7 13 3.92 38 14.24 290 157 3.17 / 1071.13 2 2
8 8 -0.16 180 14.31 284 732 3.90 / 1071.86 2 8
Average= 5.15 (KJ/cycle)

Cycle 206 GMT 15/ 3/2021 9:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 29 14.22 427 176 0.18 / 1064.29 2 2
2 3 922.12 -1 14.22 427 0 0.00 / 1064.29 2 2
3 12 1187.44 90 6.46 1939 1127 1.30 / 1065.42 2 2
4 7 1193.08 25 10.27 2058 528 1.83 / 1065.94 2 2
5 13 1039.36 38 12.35 1868 877 2.71 / 1066.82 2 2
6 13 273.68 38 13.67 753 391 3.10 / 1067.21 2 2
7 8 -0.16 180 14.28 291 748 3.85 / 1067.96 2 2
Average= 5.16 (KJ/cycle)

Cycle 205 GMT 5/ 3/2021 14:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 27 14.22 429 165 0.16 / 1060.30 2 2
2 3 1045.76 2 11.81 1876 44 0.21 / 1060.35 2 2
3 12 1179.56 90 7.77 1978 1383 1.59 / 1061.73 2 2
4 7 1179.92 25 10.54 2046 539 2.13 / 1062.27 2 2
5 13 1002.32 38 12.52 1825 868 3.00 / 1063.14 2 2
6 13 79.56 38 14.07 417 223 3.22 / 1063.36 2 2
7 8 -0.16 180 14.28 292 751 3.97 / 1064.11 2 2
Average= 5.17 (KJ/cycle)

Cycle 204 GMT 23/ 2/2021 20:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 14.20 418 166 0.17 / 1055.05 2 2
2 3 931.32 -1 14.20 418 0 0.00 / 1055.05 2 2
3 12 1196.56 3 10.92 2066 68 0.23 / 1055.12 2 2
4 12 1913.12 90 8.54 3081 2368 2.60 / 1057.49 2 2
5 7 1904.88 25 10.23 3086 789 3.39 / 1058.28 2 2
6 13 945.16 38 12.92 1740 854 4.25 / 1059.13 2 2
7 13 154.32 38 13.97 534 283 4.53 / 1059.42 2 2
8 8 -0.32 180 14.34 280 723 5.25 / 1060.14 2 2
Average= 5.17 (KJ/cycle)

Cycle 203 GMT 22/ 2/2021 16:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 26 14.12 434 159 0.16 / 1051.17 2 2
2 3 1087.00 3 11.63 1927 67 0.23 / 1051.24 2 2
3 3 1012.60 1 10.83 1820 20 0.25 / 1051.26 2 2
4 12 1171.68 90 6.31 1939 1101 1.35 / 1052.36 2 2
5 7 1179.08 25 10.24 2035 521 1.87 / 1052.88 2 2
6 13 1023.28 38 12.41 1862 878 2.75 / 1053.76 2 2
7 13 254.44 38 13.72 715 373 3.12 / 1054.13 2 2
8 8 -0.24 180 14.28 293 753 3.87 / 1054.89 2 2
Average= 5.17 (KJ/cycle)

Cycle 202 GMT 12/ 2/2021 21:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 27 14.16 420 161 0.16 / 1047.38 2 2
2 12 1180.84 90 6.61 1947 1158 1.32 / 1048.54 2 2
3 7 1185.40 25 10.28 2053 528 1.85 / 1049.07 2 2
4 13 1022.16 38 12.42 1837 867 2.71 / 1049.94 2 2
5 13 217.32 38 13.77 659 345 3.06 / 1050.28 2 2
6 8 -0.24 180 14.29 285 733 3.79 / 1051.01 2 2
Average= 5.18 (KJ/cycle)

Cycle 201 GMT 3/ 2/2021 3:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 26 14.25 428 159 0.16 / 1043.54 2 2
2 12 1188.24 90 7.76 1999 1396 1.55 / 1044.94 2 2
3 7 1188.20 25 10.58 2048 542 2.10 / 1045.48 2 2
4 13 829.80 38 12.88 1556 762 2.86 / 1046.24 2 2
5 13 90.72 38 14.04 447 238 3.10 / 1046.48 2 2
6 8 -0.28 180 14.30 290 746 3.84 / 1047.22 2 3
Average= 5.18 (KJ/cycle)

Cycle 200 GMT 24/ 1/2021 8:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 28 14.17 453 180 0.18 / 1038.32 2 2
2 12 1155.44 3 10.84 2000 65 0.24 / 1038.38 2 2
3 12 1901.52 90 8.62 3050 2366 2.61 / 1040.75 2 2
4 7 1891.48 25 10.29 3062 788 3.40 / 1041.54 2 2
5 13 919.08 38 12.97 1706 841 4.24 / 1042.38 2 2
6 13 127.56 38 14.02 491 262 4.50 / 1042.64 2 2
7 8 -0.28 180 14.33 287 740 5.24 / 1043.38 2 3
Average= 5.19 (KJ/cycle)

Cycle 199 GMT 23/ 1/2021 4:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 14.13 441 174 0.17 / 1034.41 2 2
2 3 951.40 -1 14.13 441 0 0.00 / 1034.41 2 2
3 3 1024.12 1 10.95 1835 20 0.19 / 1034.43 2 2
4 12 1206.28 90 6.24 1980 1112 1.31 / 1035.54 2 2
5 7 1211.48 25 10.16 2091 531 1.84 / 1036.07 2 2
6 13 1068.64 38 12.35 1913 898 2.74 / 1036.97 2 2
7 13 281.04 38 13.67 769 399 3.13 / 1037.37 2 2
8 8 -0.28 180 14.27 300 771 3.91 / 1038.14 2 2
Average= 5.19 (KJ/cycle)

Cycle 198 GMT 13/ 1/2021 10: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 28 14.10 455 180 0.18 / 1030.52 2 2
2 3 957.72 -1 14.10 455 0 0.00 / 1030.52 2 2
3 3 1036.00 1 11.37 1848 21 0.20 / 1030.55 2 2
4 12 1190.80 90 6.61 1963 1168 1.37 / 1031.71 2 2
5 7 1195.20 25 10.30 2050 528 1.90 / 1032.24 2 2
6 13 1033.84 38 12.39 1862 877 2.77 / 1033.12 2 2
7 13 246.48 38 13.72 696 363 3.14 / 1033.48 2 2
8 8 -0.28 180 14.28 293 753 3.89 / 1034.23 2 2
Average= 5.20 (KJ/cycle)

Cycle 197 GMT 3/ 1/2021 15:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 26 14.20 469 173 0.17 / 1026.60 2 2
2 3 1044.32 2 11.87 1866 44 0.22 / 1026.65 2 2
3 12 1203.76 90 7.71 2019 1401 1.62 / 1028.05 2 2
4 7 1205.80 25 10.57 2081 550 2.17 / 1028.60 2 2
5 13 837.88 38 12.83 1582 771 2.94 / 1029.37 2 2
6 13 99.80 38 14.03 446 238 3.18 / 1029.61 2 2
7 8 -0.20 180 14.31 286 737 3.91 / 1030.34 2 2
Average= 5.20 (KJ/cycle)

Cycle 196 GMT 24/12/2020 20:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.18 446 177 0.18 / 1021.36 2 2
2 12 1134.72 3 10.87 1970 64 0.24 / 1021.42 2 2
3 12 1900.24 90 8.64 3057 2377 2.62 / 1023.80 2 2
4 7 1889.00 25 10.30 3056 787 3.41 / 1024.59 2 2
5 13 912.40 38 12.96 1712 843 4.25 / 1025.43 2 2
6 13 72.32 38 14.17 417 225 4.47 / 1025.66 2 2
7 8 -0.04 180 14.36 300 775 5.25 / 1026.43 2 2
Average= 5.21 (KJ/cycle)

Cycle 195 GMT 23/12/2020 16:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 28 14.19 450 179 0.18 / 1017.53 2 2
2 12 1176.56 90 6.27 1950 1100 1.28 / 1018.63 2 2
3 7 1182.16 25 10.20 2043 521 1.80 / 1019.15 2 2
4 13 1040.48 38 12.38 1870 880 2.68 / 1020.03 2 2
5 13 286.72 38 13.69 764 397 3.08 / 1020.43 2 2
6 8 -0.12 180 14.30 294 757 3.83 / 1021.18 2 2
Average= 5.21 (KJ/cycle)

Cycle 194 GMT 13/12/2020 22:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 26 14.19 437 161 0.16 / 1013.67 2 2
2 12 1186.24 90 6.58 1949 1154 1.32 / 1014.82 2 2
3 7 1190.12 25 10.30 2050 528 1.84 / 1015.35 2 2
4 13 1032.60 38 12.40 1849 871 2.71 / 1016.22 2 2
5 13 233.68 38 13.74 691 361 3.08 / 1016.58 2 2
6 8 -0.16 180 14.29 299 769 3.84 / 1017.35 2 2
Average= 5.22 (KJ/cycle)

Cycle 193 GMT 4/12/2020 3:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 25 14.22 425 151 0.15 / 1009.55 2 2
2 3 1021.52 1 11.70 1842 22 0.17 / 1009.57 2 2
3 12 1196.80 90 7.75 2010 1402 1.57 / 1010.98 2 2
4 7 1199.20 25 10.59 2073 549 2.12 / 1011.52 2 2
5 13 840.32 48 12.76 1581 968 3.09 / 1012.49 2 2
6 13 64.72 48 14.13 387 262 3.35 / 1012.75 2 2
7 8 -0.24 180 14.30 291 749 4.10 / 1013.50 2 7
Average= 5.22 (KJ/cycle)

Cycle 192 GMT 24/11/2020 9:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 28 14.17 443 176 0.18 / 1004.09 2 2
2 12 1148.84 3 10.78 2003 65 0.24 / 1004.15 2 2
3 12 1910.04 90 8.82 3073 2439 2.68 / 1006.59 2 2
4 7 1899.20 25 10.34 3063 792 3.47 / 1007.39 2 2
5 13 886.68 48 12.93 1659 1030 4.50 / 1008.42 2 2
6 13 42.92 48 14.25 353 241 4.74 / 1008.66 2 2
7 8 -0.24 180 14.39 287 743 5.49 / 1009.40 2 6
Average= 5.23 (KJ/cycle)

Cycle 191 GMT 23/11/2020 5:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 14.20 439 143 0.14 / 1000.01 2 2
2 10 1050.24 5 12.28 1868 115 0.26 / 1000.12 2 2
3 12 1191.52 90 6.45 1965 1141 1.40 / 1001.26 2 2
4 7 1195.80 25 10.25 2050 525 1.92 / 1001.79 2 2
5 13 1044.80 48 12.34 1867 1106 3.03 / 1002.89 2 2
6 13 101.16 48 14.07 443 299 3.33 / 1003.19 2 2
7 8 -0.24 180 14.34 280 723 4.05 / 1003.91 2 2
Average= 5.23 (KJ/cycle)

Cycle 190 GMT 13/11/2020 10:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.22 432 178 0.18 / 996.00 2 2
2 3 920.16 -1 14.22 432 0 0.00 / 996.00 2 2
3 12 1179.88 90 6.85 1965 1211 1.39 / 997.21 2 2
4 7 1183.76 25 10.35 2049 530 1.92 / 997.74 2 2
5 13 1024.64 48 12.43 1842 1099 3.02 / 998.84 2 2
6 13 84.16 48 14.11 424 287 3.31 / 999.13 2 2
7 8 -0.16 180 14.34 285 736 4.04 / 999.86 2 3
Average= 5.23 (KJ/cycle)

Cycle 189 GMT 3/11/2020 16:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 25 14.26 456 163 0.16 / 992.29 2 2
2 3 1089.64 4 12.03 1934 93 0.26 / 992.39 2 2
3 12 1174.16 30 7.96 1960 468 0.72 / 992.85 2 2
4 7 1179.36 25 10.85 2030 551 1.27 / 993.41 2 2
5 13 1082.92 48 12.01 1929 1112 2.39 / 994.52 2 2
6 13 343.08 48 13.58 851 555 2.94 / 995.07 2 2
7 8 -0.28 180 14.30 291 749 3.69 / 995.82 2 2
Average= 5.24 (KJ/cycle)

Cycle 188 GMT 24/10/2020 21:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 23 14.25 449 147 0.15 / 987.47 2 2
2 10 1056.64 5 12.52 1918 120 0.27 / 987.59 2 2
3 12 1157.80 5 11.29 2045 115 0.38 / 987.70 2 2
4 12 1834.24 30 10.21 3002 920 1.30 / 988.62 2 2
5 7 1829.40 25 11.00 3009 827 2.13 / 989.45 2 2
6 13 1461.04 48 12.23 2503 1469 3.60 / 990.92 2 2
7 13 226.76 48 13.86 671 446 4.05 / 991.37 2 2
8 8 -0.28 180 14.36 296 765 4.81 / 992.13 2 2
Average= 5.25 (KJ/cycle)

Cycle 187 GMT 23/10/2020 17:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 14.26 440 176 0.18 / 979.63 2 2
2 3 937.28 -1 14.26 440 0 0.00 / 979.63 2 2
3 3 1015.84 1 10.67 1816 19 0.20 / 979.64 2 2
4 12 1199.68 7 6.19 1972 85 0.28 / 979.73 2 2
5 12 1909.32 175 5.03 2974 2618 2.90 / 982.35 2 2
6 12 1909.36 30 8.18 3064 752 3.65 / 983.10 2 2
7 7 1905.00 25 10.16 3109 790 4.44 / 983.89 2 2
8 13 1754.48 48 11.77 2906 1642 6.08 / 985.53 2 2
9 13 590.80 48 13.36 1239 795 6.88 / 986.33 2 2
10 13 10.24 48 14.33 311 214 7.09 / 986.54 2 2
11 8 -0.36 180 14.41 301 781 7.87 / 987.32 2 13
Average= 5.25 (KJ/cycle)

Cycle 186 GMT 13/10/2020 16:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 14.28 448 179 0.18 / 972.37 2 2
2 12 1154.16 10 6.71 1908 128 0.31 / 972.50 2 2
3 12 1861.84 175 5.17 2928 2649 2.96 / 975.15 2 2
4 12 1860.56 30 8.38 2992 752 3.71 / 975.90 2 2
5 7 1854.08 25 10.24 3036 777 4.49 / 976.68 2 2
6 13 1498.48 48 12.21 2541 1489 5.97 / 978.17 2 2
7 13 293.04 48 13.74 776 512 6.49 / 978.68 2 2
8 8 -0.16 180 14.38 297 769 7.26 / 979.45 2 2
Average= 5.24 (KJ/cycle)

Cycle 185 GMT 3/10/2020 15:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 27 14.23 455 175 0.17 / 965.00 2 2
2 3 1021.40 1 11.09 1824 20 0.20 / 965.02 2 2
3 12 1180.88 10 6.62 1947 129 0.32 / 965.15 2 2
4 12 1858.88 175 5.54 2962 2872 3.20 / 968.02 2 2
5 12 1856.44 30 8.69 3005 783 3.98 / 968.80 2 2
6 7 1847.76 25 10.36 3017 781 4.76 / 969.58 2 2
7 13 1461.36 48 12.31 2475 1462 6.22 / 971.05 2 2
8 13 169.32 48 13.96 574 385 6.61 / 971.43 2 2
9 8 -0.28 180 14.38 295 764 7.37 / 972.19 2 4
Average= 5.23 (KJ/cycle)

Cycle 184 GMT 23/ 9/2020 14:46: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 14.32 438 169 0.17 / 958.55 2 2
2 12 1162.36 10 7.69 1949 150 0.32 / 958.70 2 2
3 12 1827.64 175 6.39 2914 3259 3.58 / 961.96 2 2
4 12 1813.32 30 8.96 2937 789 4.37 / 962.75 2 2
5 7 1799.72 25 10.49 2955 775 5.14 / 963.52 2 2
6 13 293.96 48 13.69 793 521 5.66 / 964.04 2 2
7 8 -0.28 180 14.33 302 779 6.44 / 964.82 2 2
Average= 5.22 (KJ/cycle)

Cycle 183 GMT 13/ 9/2020 14: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 24 14.23 441 151 0.15 / 950.23 2 2
2 3 1072.04 3 12.00 1913 69 0.22 / 950.30 2 2
3 12 2003.56 175 5.03 3056 2690 2.91 / 952.99 2 2
4 7 2013.28 25 10.28 3247 834 3.74 / 953.83 2 2
5 13 1916.92 48 11.81 3117 1767 5.51 / 955.60 2 2
6 13 1535.04 48 12.43 2602 1552 7.06 / 957.15 2 2
7 13 235.76 48 13.89 693 462 7.53 / 957.61 2 2
8 8 -0.28 180 14.42 297 771 8.30 / 958.38 2 2
Average= 5.21 (KJ/cycle)

Cycle 182 GMT 3/ 9/2020 14:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 14.28 456 195 0.20 / 942.53 2 2
2 3 871.40 -2 14.28 456 0 0.00 / 942.53 2 2
3 3 1016.68 1 10.92 1808 20 0.22 / 942.55 2 2
4 12 2007.04 175 4.93 2659 2294 2.51 / 944.84 2 2
5 7 2016.52 25 10.12 3229 817 3.33 / 945.66 2 2
6 13 1923.88 48 11.71 3113 1750 5.08 / 947.41 2 2
7 13 1361.72 48 12.63 2312 1402 6.48 / 948.81 2 2
8 13 269.36 48 13.83 752 499 6.98 / 949.31 2 2
9 8 -0.40 180 14.40 298 772 7.75 / 950.08 2 3
Average= 5.19 (KJ/cycle)

Cycle 181 GMT 24/ 8/2020 14:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 25 14.29 457 163 0.16 / 935.25 2 2
2 10 1048.68 5 12.63 1887 119 0.28 / 935.37 2 2
3 12 1151.84 1 4.94 1893 9 0.29 / 935.38 2 2
4 12 1954.00 100 4.89 2436 1191 1.48 / 936.57 2 2
5 12 1954.36 50 5.91 3065 906 2.39 / 937.48 2 2
6 7 1951.28 40 9.55 3157 1206 3.59 / 938.68 2 2
7 13 1801.72 48 11.74 2983 1681 5.28 / 940.36 2 2
8 13 822.96 48 13.11 1584 997 6.27 / 941.36 2 2
9 13 1.80 48 14.41 296 205 6.48 / 941.57 2 2
10 8 -0.12 180 14.44 296 769 7.25 / 942.34 2 6
Average= 5.18 (KJ/cycle)

Cycle 180 GMT 14/ 8/2020 13: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 14.30 439 176 0.18 / 928.25 2 2
2 3 891.40 -1 14.30 439 0 0.00 / 928.25 2 2
3 12 1139.32 1 5.28 1895 10 0.19 / 928.26 2 2
4 12 1958.24 100 4.95 2726 1349 1.54 / 929.61 2 2
5 12 1959.32 50 6.71 3155 1059 2.59 / 930.67 2 2
6 7 1955.40 40 9.81 3148 1235 3.83 / 931.91 2 2
7 13 1780.00 48 11.74 2932 1652 5.48 / 933.56 2 2
8 13 554.84 48 13.41 1177 758 6.24 / 934.32 2 2
9 8 -0.24 180 14.39 298 772 7.01 / 935.09 2 2
Average= 5.17 (KJ/cycle)

Cycle 179 GMT 4/ 8/2020 12: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 26 14.31 450 167 0.17 / 921.57 2 2
2 3 1039.96 2 11.95 1892 45 0.21 / 921.61 2 2
3 12 1193.56 1 5.01 1976 10 0.22 / 921.62 2 2
4 12 1952.56 100 6.00 3036 1822 2.04 / 923.44 2 2
5 12 1949.04 50 8.00 3121 1248 3.29 / 924.69 2 2
6 7 1937.84 40 9.93 3148 1250 4.54 / 925.94 2 2
7 13 929.28 48 12.90 1738 1076 5.62 / 927.02 2 2
8 13 51.20 48 14.21 390 266 5.89 / 927.28 2 2
9 8 -0.24 180 14.37 307 794 6.68 / 928.08 2 4
Average= 5.16 (KJ/cycle)

Cycle 178 GMT 25/ 7/2020 11: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 14.34 435 187 0.19 / 913.05 2 2
2 3 888.48 -1 14.34 435 0 0.00 / 913.05 2 2
3 12 2001.80 100 12.12 353 428 0.61 / 913.48 2 2
4 12 2005.24 150 5.12 3322 2551 3.17 / 916.03 2 2
5 7 2010.76 40 10.10 3253 1314 4.48 / 917.34 2 2
6 13 1857.32 48 11.87 3063 1745 6.23 / 919.09 2 2
7 13 1083.96 48 12.86 1960 1210 7.44 / 920.30 2 2
8 13 89.36 48 14.17 457 311 7.75 / 920.61 2 2
9 8 -0.24 180 14.42 305 792 8.54 / 921.40 2 3
Average= 5.15 (KJ/cycle)

Cycle 177 GMT 15/ 7/2020 11:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 25 14.29 452 161 0.16 / 904.61 2 2
2 10 1028.28 4 12.74 1842 94 0.26 / 904.70 2 2
3 12 2003.52 100 12.08 332 401 0.66 / 905.10 2 2
4 12 2007.72 150 5.18 3157 2453 3.11 / 907.56 2 2
5 7 2014.80 40 10.14 3238 1313 4.42 / 908.87 2 2
6 13 1869.16 48 11.85 3064 1743 6.17 / 910.61 2 2
7 13 1068.04 48 12.89 1938 1199 7.36 / 911.81 2 2
8 13 78.76 48 14.20 417 284 7.65 / 912.10 2 2
9 8 -0.28 180 14.43 294 764 8.41 / 912.86 2 4
Average= 5.13 (KJ/cycle)

Cycle 176 GMT 5/ 7/2020 11:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 29 14.36 432 180 0.18 / 896.70 2 2
2 3 918.44 -1 14.36 432 0 0.00 / 896.70 2 2
3 12 2000.84 100 12.10 350 423 0.60 / 897.12 2 2
4 12 2004.64 150 5.80 3208 2791 3.39 / 899.91 2 2
5 7 2005.56 40 10.19 3264 1330 4.72 / 901.24 2 2
6 13 1660.04 48 12.15 2787 1625 6.35 / 902.87 2 2
7 13 611.52 48 13.40 1256 808 7.16 / 903.68 2 2
8 8 -0.28 180 14.40 298 772 7.93 / 904.45 2 2
Average= 5.11 (KJ/cycle)

Cycle 175 GMT 25/ 6/2020 11:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 26 14.34 449 167 0.17 / 889.05 2 2
2 3 1073.48 3 12.41 1919 71 0.24 / 889.12 2 2
3 12 2002.08 100 12.17 333 405 0.64 / 889.53 2 2
4 12 2006.12 150 5.96 3215 2874 3.52 / 892.40 2 2
5 7 2006.16 40 10.26 3239 1329 4.85 / 893.73 2 2
6 13 1649.16 48 12.28 2731 1610 6.46 / 895.34 2 2
7 13 233.44 48 13.91 661 441 6.90 / 895.78 2 2
8 8 -0.40 180 14.42 284 737 7.64 / 896.52 2 2
Average= 5.09 (KJ/cycle)

Cycle 174 GMT 15/ 6/2020 11:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 14.39 428 172 0.17 / 881.56 2 2
2 3 933.36 -1 14.39 428 0 0.00 / 881.56 2 2
3 3 1022.44 1 11.80 1854 22 0.19 / 881.58 2 2
4 12 2006.84 100 12.14 333 404 0.60 / 881.99 2 2
5 12 2010.84 100 5.08 3223 1637 2.24 / 883.62 2 2
6 7 2016.48 40 10.16 3249 1320 3.56 / 884.94 2 2
7 13 1883.76 48 11.94 3060 1754 5.31 / 886.70 2 2
8 13 967.44 48 13.00 1797 1121 6.43 / 887.82 2 2
9 13 68.12 48 14.27 413 283 6.71 / 888.10 2 2
10 8 -0.08 180 14.45 300 780 7.49 / 888.88 2 3
Average= 5.08 (KJ/cycle)

Cycle 173 GMT 5/ 6/2020 11:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 27 14.31 447 173 0.17 / 873.99 2 2
2 3 1017.76 1 11.90 1848 22 0.19 / 874.01 2 2
3 12 2004.64 100 12.10 337 408 0.60 / 874.42 2 2
4 12 2008.48 100 5.12 3192 1634 2.24 / 876.05 2 2
5 7 2013.72 40 10.24 3246 1330 3.57 / 877.38 2 2
6 13 1885.84 48 11.95 3055 1752 5.32 / 879.13 2 2
7 13 1098.12 48 12.87 1974 1219 6.54 / 880.35 2 2
8 13 84.04 48 14.23 424 290 6.83 / 880.64 2 2
9 8 -0.40 180 14.45 287 746 7.57 / 881.39 2 4
Average= 5.07 (KJ/cycle)

Cycle 172 GMT 26/ 5/2020 11:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 14.37 438 170 0.17 / 866.71 2 2
2 12 2003.76 100 12.05 350 422 0.59 / 867.13 2 2
3 12 2007.12 100 5.45 3147 1715 2.31 / 868.85 2 2
4 7 2009.84 40 10.23 3229 1321 3.63 / 870.17 2 2
5 13 1853.60 48 11.94 3045 1745 5.37 / 871.91 2 2
6 13 692.04 48 13.31 1383 884 6.26 / 872.80 2 2
7 13 45.56 48 14.31 367 252 6.51 / 873.05 2 2
8 8 -0.48 180 14.43 294 764 7.27 / 873.81 2 8
Average= 5.05 (KJ/cycle)

Cycle 171 GMT 16/ 5/2020 11:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 26 14.39 450 168 0.17 / 859.45 2 2
2 3 1040.76 2 12.45 1890 47 0.22 / 859.50 2 2
3 12 2007.20 100 12.08 340 411 0.63 / 859.91 2 2
4 12 2011.64 100 5.50 3180 1749 2.38 / 861.66 2 2
5 7 2015.48 25 10.60 3270 867 3.24 / 862.52 2 2
6 13 1871.64 48 12.01 3053 1760 5.00 / 864.28 2 2
7 13 1105.48 48 12.89 1972 1220 6.22 / 865.50 2 2
8 13 98.60 48 14.22 441 301 6.52 / 865.80 2 2
9 8 -0.28 180 14.46 283 737 7.26 / 866.54 2 4
Average= 5.04 (KJ/cycle)

Cycle 170 GMT 6/ 5/2020 11:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 27 14.34 436 169 0.17 / 852.19 2 2
2 3 957.20 -1 14.34 436 0 0.00 / 852.19 2 2
3 3 1035.24 1 12.14 1869 23 0.19 / 852.21 2 2
4 12 2001.48 100 12.04 348 419 0.61 / 852.63 2 2
5 12 2005.44 100 5.60 3146 1762 2.37 / 854.40 2 2
6 7 2008.24 25 10.62 3250 863 3.24 / 855.26 2 2
7 13 1877.40 48 11.99 3072 1768 5.00 / 857.03 2 2
8 13 1109.84 48 12.86 1995 1231 6.23 / 858.26 2 2
9 13 60.92 48 14.31 383 263 6.50 / 858.52 2 2
10 8 -0.32 180 14.47 292 761 7.26 / 859.28 2 4
Average= 5.03 (KJ/cycle)

Cycle 169 GMT 26/ 4/2020 11:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 25 14.37 419 151 0.15 / 844.84 2 2
2 3 1051.92 2 12.47 1883 47 0.20 / 844.89 2 2
3 12 2002.20 100 12.03 354 426 0.62 / 845.31 2 2
4 12 2005.44 100 5.99 3162 1894 2.52 / 847.21 2 2
5 7 2005.64 25 10.63 3223 857 3.37 / 848.07 2 2
6 13 1857.20 48 11.97 3059 1758 5.13 / 849.82 2 2
7 13 1041.32 48 12.95 1881 1169 6.30 / 850.99 2 2
8 13 68.76 48 14.27 400 274 6.57 / 851.27 2 2
9 8 -0.44 180 14.45 291 757 7.33 / 852.02 2 6
Average= 5.01 (KJ/cycle)

Cycle 168 GMT 16/ 4/2020 12:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 14.43 423 165 0.16 / 838.06 2 2
2 3 953.44 -1 14.43 423 0 0.00 / 838.06 2 2
3 3 1028.36 1 12.00 1849 22 0.19 / 838.08 2 2
4 12 2002.80 80 11.95 333 318 0.51 / 838.40 2 2
5 12 2006.08 84 5.30 3111 1385 1.89 / 839.78 2 2
6 7 2010.08 45 10.21 3227 1483 3.37 / 841.26 2 2
7 13 1845.76 42 12.14 3023 1541 4.91 / 842.81 2 2
8 13 879.80 42 13.19 1639 908 5.82 / 843.71 2 2
9 13 66.60 42 14.31 388 233 6.06 / 843.95 2 2
10 8 -0.04 180 14.47 286 745 6.80 / 844.69 2 4
Average= 5.00 (KJ/cycle)

Cycle 167 GMT 6/ 4/2020 12:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 26 14.37 419 157 0.16 / 831.11 2 2
2 3 1041.16 2 12.39 1885 47 0.20 / 831.16 2 2
3 12 2003.32 80 11.94 329 314 0.52 / 831.47 2 2
4 12 2005.44 84 5.34 3061 1373 1.89 / 832.84 2 2
5 7 2007.92 45 10.29 3214 1488 3.38 / 834.33 2 2
6 13 1858.60 42 12.16 3031 1548 4.93 / 835.88 2 2
7 13 1048.60 42 13.04 1893 1037 5.96 / 836.92 2 2
8 13 81.60 42 14.28 414 248 6.21 / 837.16 2 2
9 8 -0.28 180 14.48 279 727 6.94 / 837.89 2 3
Average= 4.99 (KJ/cycle)

Cycle 166 GMT 27/ 3/2020 12:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 14.41 418 169 0.17 / 824.60 2 2
2 3 947.44 -1 14.41 418 0 0.00 / 824.60 2 2
3 3 1030.12 1 12.18 1854 23 0.19 / 824.62 2 2
4 12 2002.72 80 11.91 328 313 0.50 / 824.94 2 2
5 12 2006.04 84 6.16 3082 1595 2.10 / 826.53 2 2
6 7 2007.04 25 10.66 3225 859 2.96 / 827.39 2 2
7 13 1851.96 42 12.15 3023 1543 4.50 / 828.93 2 2
8 13 1053.12 42 13.03 1896 1038 5.54 / 829.97 2 2
9 13 88.52 42 14.28 417 250 5.79 / 830.22 2 2
10 8 -0.32 180 14.49 280 730 6.52 / 830.95 2 4
Average= 4.98 (KJ/cycle)

Cycle 165 GMT 17/ 3/2020 12:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 28 14.43 421 170 0.17 / 818.11 2 2
2 12 2003.32 80 11.81 329 311 0.48 / 818.42 2 2
3 12 2006.72 84 5.62 3055 1442 1.92 / 819.86 2 2
4 7 2010.04 25 10.65 3256 867 2.79 / 820.73 2 2
5 13 1890.80 42 12.15 3075 1569 4.36 / 822.30 2 2
6 13 1144.08 42 12.96 2030 1105 5.46 / 823.40 2 2
7 13 150.36 42 14.16 525 312 5.78 / 823.71 2 2
8 8 -0.36 180 14.47 276 719 6.50 / 824.43 2 2
Average= 4.97 (KJ/cycle)

Cycle 164 GMT 7/ 3/2020 12:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.42 419 169 0.17 / 811.76 2 2
2 12 2003.92 84 4.97 2734 1141 1.31 / 812.90 2 2
3 7 2007.64 24 10.62 3263 832 2.14 / 813.73 2 2
4 13 1905.60 42 12.08 3109 1577 3.72 / 815.31 2 2
5 13 1557.32 42 12.58 2598 1373 5.09 / 816.68 2 2
6 13 347.28 42 13.81 867 503 5.60 / 817.19 2 2
7 8 -0.32 180 14.45 289 752 6.35 / 817.94 2 2
Average= 4.96 (KJ/cycle)

Cycle 163 GMT 26/ 2/2020 12: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 25 14.36 417 150 0.15 / 805.68 2 2
2 3 1067.24 3 11.99 1892 68 0.22 / 805.75 2 2
3 12 2002.40 84 4.89 2391 982 1.20 / 806.73 2 2
4 7 2007.40 25 10.32 3241 836 2.04 / 807.57 2 2
5 13 1910.64 42 11.83 3115 1548 3.58 / 809.11 2 2
6 13 1361.44 42 12.69 2325 1239 4.82 / 810.35 2 2
7 13 352.68 42 13.81 865 502 5.32 / 810.86 2 2
8 8 -0.28 180 14.45 283 736 6.06 / 811.59 2 2
Average= 4.95 (KJ/cycle)

Cycle 162 GMT 16/ 2/2020 12:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 28 14.33 443 178 0.18 / 801.29 2 2
2 3 939.56 -1 14.33 443 0 0.00 / 801.29 2 2
3 3 1023.36 1 11.45 1817 21 0.20 / 801.31 2 2
4 12 1180.16 84 8.85 2045 1520 1.72 / 802.83 2 2
5 12 961.28 64 11.51 1731 1275 2.99 / 804.10 2 2
6 7 946.36 24 11.93 1712 490 3.48 / 804.59 2 2
7 13 54.04 42 14.29 358 215 3.70 / 804.81 2 2
8 8 -0.20 180 14.39 279 723 4.42 / 805.53 2 4
Average= 4.94 (KJ/cycle)

Cycle 161 GMT 6/ 2/2020 13:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 29 14.36 445 185 0.19 / 796.85 2 2
2 3 954.24 -1 14.36 445 0 0.00 / 796.85 2 2
3 3 1036.88 1 11.33 1854 21 0.21 / 796.87 2 2
4 12 1187.72 84 9.09 2033 1552 1.76 / 798.43 2 2
5 12 901.88 64 11.66 1645 1228 2.99 / 799.65 2 2
6 7 889.60 25 12.04 1640 494 3.48 / 800.15 2 2
7 13 36.52 42 14.31 348 209 3.69 / 800.36 2 2
8 8 -0.16 180 14.38 291 753 4.44 / 801.11 2 3
Average= 4.95 (KJ/cycle)

Cycle 160 GMT 27/ 1/2020 15:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 25 14.33 461 165 0.17 / 792.60 2 2
2 3 1099.32 4 12.03 1975 95 0.26 / 792.70 2 2
3 12 1175.24 84 9.80 2024 1666 1.93 / 794.36 2 2
4 12 764.68 64 12.08 1462 1130 3.06 / 795.49 2 2
5 7 751.48 25 12.36 1439 445 3.50 / 795.94 2 2
6 8 0.04 180 14.39 281 728 4.23 / 796.67 2 2
Average= 4.95 (KJ/cycle)

Cycle 159 GMT 17/ 1/2020 17: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 14.41 426 178 0.18 / 788.76 2 2
2 3 918.56 -1 14.41 426 0 0.00 / 788.76 2 2
3 12 1208.44 84 9.78 2060 1692 1.87 / 790.46 2 2
4 12 486.80 64 13.00 1047 871 2.74 / 791.33 2 2
5 7 472.68 25 13.22 1032 341 3.08 / 791.67 2 2
6 8 -0.24 180 14.34 298 769 3.85 / 792.44 2 2
Average= 4.95 (KJ/cycle)

Cycle 158 GMT 7/ 1/2020 19:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 26 14.38 436 163 0.16 / 782.76 2 2
2 3 1075.76 3 12.62 1934 73 0.24 / 782.83 2 2
3 12 2007.28 64 6.96 2902 1293 1.53 / 784.12 2 2
4 7 2005.24 25 10.83 3264 884 2.41 / 785.01 2 2
5 13 1835.08 42 12.13 3034 1546 3.96 / 786.55 2 2
6 13 1043.32 42 13.02 1888 1032 4.99 / 787.58 2 2
7 13 83.92 42 14.27 429 257 5.25 / 787.84 2 2
8 8 -0.32 180 14.45 286 744 5.99 / 788.59 2 3
Average= 4.96 (KJ/cycle)

Cycle 157 GMT 28/12/2019 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 14.41 440 178 0.18 / 776.89 2 2
2 3 942.64 -1 14.41 440 0 0.00 / 776.89 2 2
3 3 1013.40 1 10.80 1849 20 0.20 / 776.91 2 2
4 12 2001.72 64 6.80 2859 1244 1.44 / 778.15 2 2
5 7 2001.44 25 10.86 3233 878 2.32 / 779.03 2 2
6 13 1852.80 42 12.11 3035 1544 3.86 / 780.57 2 2
7 13 1038.20 42 13.02 1883 1030 4.89 / 781.60 2 2
8 13 74.56 42 14.30 406 244 5.14 / 781.85 2 2
9 8 -0.12 180 14.45 287 746 5.88 / 782.59 2 3
Average= 4.95 (KJ/cycle)

Cycle 156 GMT 18/12/2019 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 28 14.38 453 182 0.18 / 771.03 2 2
2 12 2006.08 64 6.89 2905 1281 1.46 / 772.31 2 2
3 7 2005.20 25 10.88 3243 882 2.35 / 773.19 2 2
4 13 1851.28 42 12.09 3059 1553 3.90 / 774.74 2 2
5 13 864.04 42 13.17 1654 915 4.81 / 775.66 2 2
6 13 91.72 42 14.25 455 272 5.09 / 775.93 2 2
7 8 -0.24 180 14.42 301 781 5.87 / 776.71 2 3
Average= 4.95 (KJ/cycle)

Cycle 155 GMT 8/12/2019 20:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 14.34 452 181 0.18 / 765.89 2 2
2 12 1179.28 1 4.78 1490 7 0.19 / 765.90 2 2
3 12 1957.68 64 7.82 2947 1475 1.66 / 767.37 2 2
4 7 1950.68 25 10.97 3158 866 2.53 / 768.24 2 2
5 13 1422.32 42 12.53 2457 1293 3.82 / 769.53 2 2
6 13 409.80 42 13.69 962 553 4.38 / 770.09 2 2
7 8 -0.20 180 14.40 292 757 5.13 / 770.84 2 2
Average= 4.94 (KJ/cycle)

Cycle 154 GMT 28/11/2019 19: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 26 14.40 443 166 0.17 / 760.69 2 2
2 3 1047.76 2 12.36 1883 47 0.21 / 760.74 2 2
3 12 1186.80 1 4.80 1567 8 0.22 / 760.74 2 2
4 12 1926.76 64 8.41 2974 1601 1.82 / 762.34 2 2
5 7 1918.88 25 11.00 3111 856 2.68 / 763.20 2 2
6 13 1354.68 42 12.60 2355 1246 3.92 / 764.45 2 2
7 13 338.92 42 13.78 853 494 4.42 / 764.94 2 2
8 8 0.32 180 14.38 298 771 5.19 / 765.71 2 2
Average= 4.94 (KJ/cycle)

Cycle 153 GMT 18/11/2019 17:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 26 14.40 448 168 0.17 / 755.14 2 2
2 12 2004.32 55 7.90 2945 1280 1.45 / 756.42 2 2
3 7 2003.48 25 10.69 3237 865 2.31 / 757.28 2 2
4 13 1834.40 42 12.08 3010 1527 3.84 / 758.81 2 2
5 13 657.32 42 13.40 1324 745 4.58 / 759.55 2 2
6 13 49.68 42 14.35 358 216 4.80 / 759.77 2 2
7 8 -0.28 180 14.43 290 753 5.55 / 760.52 2 5
Average= 4.94 (KJ/cycle)

Cycle 152 GMT 8/11/2019 17:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 14.39 449 168 0.17 / 749.30 2 2
2 12 2000.68 55 8.08 2979 1324 1.49 / 750.62 2 2
3 7 2000.28 25 10.70 3250 869 2.36 / 751.49 2 2
4 13 1840.24 42 12.08 3042 1543 3.90 / 753.03 2 2
5 13 829.28 42 13.19 1600 886 4.79 / 753.92 2 2
6 13 72.24 42 14.27 424 254 5.05 / 754.17 2 2
7 8 -0.32 180 14.39 307 795 5.84 / 754.97 2 4
Average= 4.93 (KJ/cycle)

Cycle 151 GMT 29/10/2019 18:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.34 461 192 0.19 / 743.79 2 2
2 3 950.76 -1 14.34 461 0 0.00 / 743.79 2 2
3 3 1026.04 1 11.95 1856 22 0.21 / 743.82 2 2
4 12 2001.56 55 8.43 3026 1403 1.62 / 745.22 2 2
5 7 1999.08 25 10.74 3201 859 2.48 / 746.08 2 2
6 13 1656.60 42 12.31 2760 1427 3.90 / 747.51 2 2
7 13 488.44 42 13.58 1081 617 4.52 / 748.12 2 2
8 13 52.44 42 14.31 384 231 4.75 / 748.35 2 2
9 8 -0.40 180 14.38 300 777 5.53 / 749.13 2 7
Average= 4.93 (KJ/cycle)

Cycle 150 GMT 19/10/2019 18:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 29 14.32 472 196 0.20 / 738.14 2 2
2 12 2002.52 52 8.32 2972 1286 1.48 / 739.43 2 2
3 7 2001.40 25 10.71 3224 863 2.35 / 740.29 2 2
4 13 1653.96 42 12.26 2773 1428 3.77 / 741.72 2 2
5 13 859.24 42 13.16 1631 901 4.67 / 742.62 2 2
6 13 32.24 42 14.37 347 209 4.88 / 742.83 2 2
7 8 -0.28 180 14.41 297 770 5.65 / 743.60 2 6
Average= 4.92 (KJ/cycle)

Cycle 149 GMT 9/10/2019 18:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 26 14.42 457 171 0.17 / 732.46 2 2
2 3 1072.80 3 12.48 1937 73 0.24 / 732.53 2 2
3 12 2007.80 52 8.73 3083 1400 1.64 / 733.93 2 2
4 7 2006.88 25 10.74 3248 872 2.52 / 734.80 2 2
5 13 1643.72 42 12.31 2742 1418 3.93 / 736.22 2 2
6 13 644.56 42 13.41 1308 737 4.67 / 736.95 2 2
7 13 34.80 42 14.35 359 216 4.89 / 737.17 2 2
8 8 -0.32 180 14.40 300 778 5.66 / 737.95 2 5
Average= 4.92 (KJ/cycle)

Cycle 148 GMT 29/ 9/2019 18:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 26 14.39 439 164 0.16 / 727.15 2 2
2 12 2002.16 52 8.79 3039 1389 1.55 / 728.54 2 2
3 7 1999.48 24 10.80 3225 836 2.39 / 729.37 2 2
4 13 1649.56 42 12.26 2765 1424 3.81 / 730.80 2 2
5 13 648.68 42 13.40 1321 743 4.56 / 731.54 2 2
6 8 -0.08 180 14.43 287 745 5.30 / 732.28 2 2
Average= 4.91 (KJ/cycle)

Cycle 147 GMT 19/ 9/2019 18:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 14.38 435 175 0.18 / 721.31 2 2
2 3 948.52 -1 14.38 435 0 0.00 / 721.31 2 2
3 3 1028.92 1 11.96 1858 22 0.20 / 721.33 2 2
4 12 2001.64 52 9.09 3064 1448 1.65 / 722.78 2 2
5 7 2000.44 25 10.75 3254 875 2.52 / 723.65 2 2
6 13 1833.12 42 12.10 3008 1529 4.05 / 725.18 2 2
7 13 764.00 42 13.27 1489 830 4.88 / 726.01 2 2
8 13 30.56 42 14.37 345 208 5.09 / 726.22 2 2
9 8 -0.36 180 14.41 295 765 5.85 / 726.98 2 4
Average= 4.91 (KJ/cycle)

Cycle 146 GMT 9/ 9/2019 19: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 27 14.39 451 175 0.18 / 715.85 2 2
2 3 1015.52 1 11.23 1856 21 0.20 / 715.87 2 2
3 12 2002.00 52 9.24 3072 1476 1.67 / 717.34 2 2
4 7 1999.12 25 10.78 3224 869 2.54 / 718.21 2 2
5 13 1646.96 42 12.31 2761 1427 3.97 / 719.64 2 2
6 13 621.72 42 13.43 1285 725 4.69 / 720.37 2 2
7 8 0.04 180 14.40 295 765 5.46 / 721.13 2 2
Average= 4.91 (KJ/cycle)

Cycle 145 GMT 30/ 8/2019 19:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 27 14.37 439 170 0.17 / 710.18 2 2
2 12 2003.28 52 9.00 3068 1436 1.61 / 711.61 2 2
3 7 2001.64 25 10.78 3230 870 2.48 / 712.48 2 2
4 13 1831.08 42 12.09 3017 1532 4.01 / 714.02 2 2
5 13 597.68 42 13.46 1256 710 4.72 / 714.73 2 2
6 13 32.16 42 14.38 330 199 4.92 / 714.92 2 2
7 8 -0.24 180 14.42 288 748 5.67 / 715.67 2 7
Average= 4.90 (KJ/cycle)

Cycle 144 GMT 20/ 8/2019 19:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 14.44 440 172 0.17 / 704.96 2 2
2 12 2001.76 52 9.22 3070 1472 1.64 / 706.43 2 2
3 7 1998.84 25 10.78 3214 866 2.51 / 707.30 2 2
4 13 1475.88 42 12.48 2508 1315 3.82 / 708.61 2 2
5 13 513.60 42 13.57 1127 642 4.47 / 709.25 2 2
6 8 -0.12 180 14.41 290 752 5.22 / 710.01 2 2
Average= 4.90 (KJ/cycle)

Cycle 143 GMT 10/ 8/2019 19:11: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 14.37 465 180 0.18 / 699.10 2 2
2 12 2005.84 49 9.21 3110 1404 1.58 / 700.51 2 2
3 7 2003.96 25 10.79 3262 880 2.46 / 701.39 2 2
4 13 1825.40 42 12.08 3040 1542 4.01 / 702.93 2 2
5 13 776.60 42 13.23 1536 853 4.86 / 703.78 2 2
6 13 59.32 42 14.31 389 234 5.09 / 704.02 2 2
7 8 -0.24 180 14.39 298 772 5.87 / 704.79 2 2
Average= 4.89 (KJ/cycle)

Cycle 142 GMT 31/ 7/2019 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 14.43 446 174 0.17 / 693.36 2 2
2 12 2013.28 49 9.33 3106 1420 1.59 / 694.78 2 2
3 7 2012.24 25 10.76 3276 881 2.47 / 695.66 2 2
4 13 1837.36 42 12.06 3046 1543 4.02 / 697.20 2 2
5 13 599.64 42 13.43 1281 723 4.74 / 697.92 2 2
6 13 2.60 42 14.42 318 193 4.93 / 698.12 2 2
7 8 -0.32 180 14.37 312 807 5.74 / 698.92 2 5
Average= 4.89 (KJ/cycle)

Cycle 141 GMT 21/ 7/2019 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 26 14.39 438 164 0.16 / 688.02 2 2
2 3 1028.44 1 12.22 1856 23 0.19 / 688.05 2 2
3 12 2004.52 49 9.62 3096 1459 1.65 / 689.51 2 2
4 7 2002.36 25 10.86 3217 873 2.52 / 690.38 2 2
5 13 1644.24 42 12.33 2740 1419 3.94 / 691.80 2 2
6 13 463.16 42 13.60 1069 611 4.55 / 692.41 2 2
7 8 -0.20 180 14.39 299 774 5.32 / 693.18 2 2
Average= 4.88 (KJ/cycle)

Cycle 140 GMT 11/ 7/2019 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 28 14.37 434 175 0.17 / 682.86 2 2
2 3 954.92 -1 14.37 434 0 0.00 / 682.86 2 2
3 12 2002.96 49 9.61 3096 1458 1.63 / 684.32 2 2
4 7 2001.20 25 10.82 3210 868 2.50 / 685.19 2 2
5 13 1483.00 42 12.48 2518 1320 3.82 / 686.51 2 2
6 13 468.12 42 13.62 1046 598 4.42 / 687.10 2 2
7 8 -0.24 180 14.38 292 756 5.17 / 687.86 2 2
Average= 4.88 (KJ/cycle)

Cycle 139 GMT 1/ 7/2019 19:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 26 14.43 433 162 0.16 / 677.53 2 2
2 3 1040.64 1 12.09 1875 23 0.19 / 677.55 2 2
3 3 1029.16 1 11.77 1867 22 0.21 / 677.57 2 2
4 12 2007.88 49 9.95 3140 1531 1.74 / 679.10 2 2
5 7 2006.56 25 10.83 3253 881 2.62 / 679.98 2 2
6 13 1500.28 42 12.47 2536 1328 3.95 / 681.31 2 2
7 13 473.92 42 13.61 1068 610 4.56 / 681.92 2 2
8 8 -0.24 180 14.38 294 761 5.32 / 682.68 2 2
Average= 4.88 (KJ/cycle)

Cycle 138 GMT 21/ 6/2019 20: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 14.40 434 175 0.17 / 672.19 2 2
2 3 927.88 -1 14.40 434 0 0.00 / 672.19 2 2
3 12 2003.84 41 9.79 3149 1264 1.44 / 673.46 2 2
4 7 2001.84 32 10.75 3250 1118 2.56 / 674.57 2 2
5 13 1823.28 32 12.37 3002 1188 3.75 / 675.76 2 2
6 13 814.92 32 13.31 1565 667 4.41 / 676.43 2 2
7 13 96.16 32 14.29 435 199 4.61 / 676.63 2 2
8 8 -0.28 180 14.43 284 738 5.35 / 677.37 2 2
Average= 4.87 (KJ/cycle)

Cycle 137 GMT 11/ 6/2019 20: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 28 14.41 446 180 0.18 / 666.87 2 2
2 12 2011.68 41 9.64 3136 1239 1.42 / 668.11 2 2
3 7 2011.36 32 10.73 3242 1113 2.53 / 669.22 2 2
4 13 1650.76 32 12.53 2767 1109 3.64 / 670.33 2 2
5 13 874.52 32 13.24 1665 705 4.35 / 671.04 2 2
6 13 126.20 32 14.21 498 226 4.57 / 671.27 2 2
7 8 -0.28 180 14.40 290 752 5.33 / 672.02 2 2
Average= 4.87 (KJ/cycle)

Cycle 136 GMT 1/ 6/2019 19:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 14.43 440 178 0.18 / 661.90 2 2
2 12 2000.92 41 9.88 3098 1255 1.43 / 663.15 2 2
3 7 1999.44 32 10.77 3203 1104 2.54 / 664.26 2 2
4 13 1446.36 32 12.73 2478 1009 3.55 / 665.27 2 2
5 13 503.48 32 13.63 1114 486 4.03 / 665.75 2 2
6 13 69.32 32 14.32 407 187 4.22 / 665.94 2 2
7 8 -0.32 180 14.40 291 754 4.97 / 666.69 2 2
Average= 4.87 (KJ/cycle)

Cycle 135 GMT 22/ 5/2019 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 28 14.42 444 179 0.18 / 656.63 2 2
2 12 2001.52 41 9.89 3086 1251 1.43 / 657.88 2 2
3 7 1999.40 32 10.77 3225 1111 2.54 / 658.99 2 2
4 13 1638.72 32 12.55 2747 1103 3.65 / 660.09 2 2
5 13 832.72 32 13.30 1596 679 4.32 / 660.77 2 2
6 13 100.36 32 14.26 452 206 4.53 / 660.98 2 2
7 8 -0.28 180 14.41 286 742 5.27 / 661.72 2 2
Average= 4.87 (KJ/cycle)

Cycle 134 GMT 12/ 5/2019 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 14.40 457 184 0.18 / 651.51 2 2
2 12 2004.16 41 9.98 3124 1278 1.46 / 652.79 2 2
3 7 2003.36 32 10.76 3234 1114 2.58 / 653.90 2 2
4 13 1475.52 32 12.71 2506 1019 3.60 / 654.92 2 2
5 13 695.16 32 13.43 1389 597 4.19 / 655.51 2 2
6 13 59.52 32 14.34 387 178 4.37 / 655.69 2 2
7 8 -0.24 180 14.40 291 754 5.12 / 656.45 2 2
Average= 4.86 (KJ/cycle)

Cycle 133 GMT 2/ 5/2019 19:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 28 14.41 457 184 0.18 / 646.25 2 2
2 12 2003.44 41 9.97 3110 1271 1.46 / 647.52 2 2
3 7 2001.08 32 10.77 3218 1109 2.56 / 648.63 2 2
4 13 1621.96 32 12.55 2759 1108 3.67 / 649.74 2 2
5 13 654.00 32 13.47 1348 581 4.25 / 650.32 2 2
6 13 112.20 32 14.21 500 227 4.48 / 650.55 2 2
7 8 -0.36 180 14.39 299 774 5.26 / 651.32 2 2
Average= 4.86 (KJ/cycle)

Cycle 132 GMT 22/ 4/2019 19:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 26 14.41 454 170 0.17 / 640.98 2 2
2 3 1049.00 1 12.22 1892 23 0.19 / 641.00 2 2
3 3 1029.96 1 11.90 1848 22 0.22 / 641.02 2 2
4 12 2001.52 41 10.10 3126 1294 1.51 / 642.32 2 2
5 7 1999.24 32 10.84 3235 1122 2.63 / 643.44 2 2
6 13 1622.36 32 12.59 2721 1096 3.73 / 644.54 2 2
7 13 648.40 32 13.48 1325 572 4.30 / 645.11 2 2
8 13 61.68 32 14.33 400 183 4.48 / 645.29 2 2
9 8 -0.20 180 14.40 299 775 5.26 / 646.07 2 4
Average= 4.86 (KJ/cycle)

Cycle 131 GMT 12/ 4/2019 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 28 14.41 446 180 0.18 / 635.47 2 2
2 3 916.00 -1 14.41 446 0 0.00 / 635.47 2 2
3 12 2003.48 39 10.16 3120 1236 1.42 / 636.70 2 2
4 7 2002.00 32 10.86 3209 1115 2.53 / 637.82 2 2
5 13 1476.08 40 12.55 2508 1259 3.79 / 639.08 2 2
6 13 667.88 40 13.38 1373 735 4.53 / 639.81 2 2
7 13 38.80 40 14.35 368 211 4.74 / 640.02 2 2
8 8 -0.40 180 14.36 304 786 5.52 / 640.81 2 4
Average= 4.85 (KJ/cycle)

Cycle 130 GMT 2/ 4/2019 19:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 14.40 451 182 0.18 / 629.84 2 2
2 12 2004.68 39 10.12 3123 1233 1.41 / 631.07 2 2
3 7 2002.72 32 10.81 3215 1112 2.53 / 632.19 2 2
4 13 1647.08 40 12.35 2782 1374 3.90 / 633.56 2 2
5 13 642.92 40 13.41 1339 718 4.62 / 634.28 2 2
6 13 39.28 40 14.35 374 215 4.83 / 634.49 2 2
7 8 -0.36 180 14.36 307 794 5.63 / 635.29 2 5
Average= 4.85 (KJ/cycle)

Cycle 129 GMT 23/ 3/2019 19:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 28 14.40 447 180 0.18 / 624.67 2 2
2 12 2001.48 38 10.12 3125 1202 1.38 / 625.87 2 2
3 7 2000.16 32 10.78 3239 1117 2.50 / 626.99 2 2
4 13 1647.68 31 12.53 2783 1081 3.58 / 628.07 2 2
5 13 689.24 31 13.43 1408 586 4.17 / 628.66 2 2
6 13 127.08 31 14.18 527 232 4.40 / 628.89 2 2
7 8 -0.32 180 14.39 297 769 5.17 / 629.66 2 2
Average= 4.84 (KJ/cycle)

Cycle 128 GMT 13/ 3/2019 19:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 14.42 444 173 0.17 / 619.53 2 2
2 3 1028.92 1 11.37 1873 21 0.19 / 619.56 2 2
3 3 1020.48 1 10.25 1826 19 0.21 / 619.57 2 2
4 12 2006.40 38 10.25 3145 1225 1.44 / 620.80 2 2
5 7 2004.64 32 10.84 3223 1118 2.56 / 621.92 2 2
6 13 1630.12 31 12.59 2737 1068 3.62 / 622.99 2 2
7 13 634.40 31 13.48 1325 554 4.18 / 623.54 2 2
8 13 68.80 31 14.32 411 182 4.36 / 623.72 2 2
9 8 -0.24 180 14.41 297 770 5.13 / 624.49 2 2
Average= 4.84 (KJ/cycle)

Cycle 127 GMT 3/ 3/2019 19:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 14.40 434 169 0.17 / 614.41 2 2
2 3 956.80 -1 14.40 434 0 0.00 / 614.41 2 2
3 3 1040.48 1 11.93 1887 23 0.19 / 614.44 2 2
4 12 2002.60 38 10.19 3132 1213 1.40 / 615.65 2 2
5 7 1999.68 32 10.86 3229 1122 2.53 / 616.77 2 2
6 13 1648.56 31 12.56 2776 1081 3.61 / 617.85 2 2
7 13 673.20 31 13.46 1373 573 4.18 / 618.42 2 2
8 13 73.16 31 14.33 411 183 4.36 / 618.61 2 2
9 8 -0.24 180 14.41 291 755 5.12 / 619.36 2 2
Average= 4.84 (KJ/cycle)

Cycle 126 GMT 21/ 2/2019 19:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 14.46 440 172 0.17 / 609.30 2 2
2 12 2002.08 32 10.05 3103 998 1.17 / 610.30 2 2
3 7 2000.84 32 10.86 3226 1121 2.29 / 611.42 2 2
4 13 1660.16 28 12.59 2807 990 3.28 / 612.41 2 2
5 13 899.44 28 13.27 1718 638 3.92 / 613.05 2 2
6 13 308.48 28 13.91 806 314 4.23 / 613.36 2 2
7 13 27.88 28 14.42 331 134 4.37 / 613.50 2 2
8 8 -0.24 180 14.39 289 749 5.11 / 614.24 2 2
Average= 4.84 (KJ/cycle)

Cycle 125 GMT 11/ 2/2019 19:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 14.42 448 174 0.17 / 604.35 2 2
2 3 1030.04 1 11.10 1877 21 0.20 / 604.37 2 2
3 12 2003.28 32 10.21 3144 1027 1.22 / 605.39 2 2
4 7 2002.08 32 10.94 3257 1140 2.36 / 606.53 2 2
5 13 1499.92 28 12.75 2566 916 3.28 / 607.45 2 2
6 13 943.60 28 13.23 1779 659 3.94 / 608.11 2 2
7 13 179.32 28 14.12 609 241 4.18 / 608.35 2 2
8 8 -0.24 180 14.39 301 780 4.96 / 609.13 2 2
Average= 4.83 (KJ/cycle)

Cycle 124 GMT 1/ 2/2019 19:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 14.47 439 172 0.17 / 599.16 2 2
2 12 2003.76 30 10.09 3119 944 1.12 / 600.10 2 2
3 7 2001.84 32 10.89 3270 1140 2.26 / 601.24 2 2
4 13 1659.44 28 12.61 2790 985 3.24 / 602.23 2 2
5 13 1087.72 28 13.11 1982 728 3.97 / 602.96 2 2
6 13 278.28 28 13.93 768 300 4.27 / 603.26 2 2
7 13 23.24 28 14.42 344 139 4.41 / 603.39 2 2
8 8 -0.20 180 14.38 300 777 5.18 / 604.17 2 2
Average= 4.83 (KJ/cycle)

Cycle 123 GMT 22/ 1/2019 18:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 27 14.44 431 168 0.17 / 594.12 2 2
2 12 2001.64 30 10.14 3109 946 1.11 / 595.07 2 2
3 7 2000.36 32 10.91 3234 1129 2.24 / 596.20 2 2
4 13 1823.08 28 12.44 3052 1063 3.31 / 597.26 2 2
5 13 885.96 28 13.30 1674 623 3.93 / 597.88 2 2
6 13 300.76 28 13.92 799 311 4.24 / 598.19 2 2
7 8 -0.24 180 14.38 307 795 5.04 / 598.99 2 2
Average= 4.83 (KJ/cycle)

Cycle 122 GMT 12/ 1/2019 18:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 28 14.39 445 179 0.18 / 588.96 2 2
2 3 904.80 -2 14.39 445 0 0.00 / 588.96 2 2
3 3 1054.28 1 12.06 1885 23 0.20 / 588.98 2 2
4 12 2000.56 30 10.18 3136 958 1.16 / 589.94 2 2
5 7 1999.44 32 11.00 3219 1133 2.29 / 591.07 2 2
6 13 1646.00 28 12.60 2792 985 3.28 / 592.05 2 2
7 13 1056.76 28 13.14 1927 709 3.99 / 592.76 2 2
8 13 260.20 28 13.98 736 288 4.27 / 593.05 2 2
9 13 9.28 28 14.44 317 128 4.40 / 593.18 2 2
10 8 -0.16 180 14.37 299 773 5.18 / 593.95 2 4
Average= 4.83 (KJ/cycle)

Cycle 121 GMT 2/ 1/2019 18:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 14.39 444 179 0.18 / 583.70 2 2
2 12 2010.68 30 10.14 3130 952 1.13 / 584.66 2 2
3 7 2010.44 32 10.94 3243 1135 2.27 / 585.79 2 2
4 13 1843.76 28 12.41 3067 1066 3.33 / 586.86 2 2
5 13 1067.72 28 13.15 1936 713 4.04 / 587.57 2 2
6 13 292.16 28 13.93 785 306 4.35 / 587.88 2 2
7 13 12.84 28 14.44 322 130 4.48 / 588.01 2 2
8 8 -0.32 180 14.37 298 771 5.25 / 588.78 2 2
Average= 4.83 (KJ/cycle)

Cycle 120 GMT 23/12/2018 18:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 28 14.39 457 184 0.18 / 578.69 2 2
2 12 2003.12 30 10.17 3131 955 1.14 / 579.65 2 2
3 7 2002.84 32 10.96 3209 1125 2.26 / 580.78 2 2
4 13 1827.40 28 12.44 3039 1059 3.32 / 581.83 2 2
5 13 874.76 28 13.32 1656 618 3.94 / 582.45 2 2
6 13 299.68 28 13.92 794 309 4.25 / 582.76 2 2
7 8 -0.16 180 14.38 295 764 5.01 / 583.52 2 2
Average= 4.82 (KJ/cycle)

Cycle 119 GMT 13/12/2018 18:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.43 450 182 0.18 / 573.69 2 2
2 12 2003.92 30 10.23 3117 957 1.14 / 574.65 2 2
3 7 2002.96 32 10.96 3219 1129 2.27 / 575.77 2 2
4 13 1829.24 28 12.45 3011 1050 3.32 / 576.82 2 2
5 13 882.04 28 13.31 1660 619 3.94 / 577.44 2 2
6 13 296.68 28 13.89 813 316 4.25 / 577.76 2 2
7 8 -0.28 180 14.39 290 751 5.00 / 578.51 2 2
Average= 4.82 (KJ/cycle)

Cycle 118 GMT 3/12/2018 18:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.44 451 182 0.18 / 568.58 2 2
2 12 2007.44 30 10.18 3139 959 1.14 / 569.54 2 2
3 7 2007.04 32 11.01 3212 1132 2.27 / 570.67 2 2
4 13 1833.68 28 12.48 3001 1049 3.32 / 571.72 2 2
5 13 1066.96 28 13.15 1944 716 4.04 / 572.44 2 2
6 13 281.48 28 13.94 770 301 4.34 / 572.74 2 2
7 8 -0.16 180 14.38 297 769 5.11 / 573.51 2 2
Average= 4.82 (KJ/cycle)

Cycle 117 GMT 23/11/2018 18:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 14.44 448 181 0.18 / 563.45 2 2
2 3 970.72 -1 14.44 448 0 0.00 / 563.45 2 2
3 3 1048.68 1 12.10 1899 23 0.20 / 563.48 2 2
4 12 2005.48 30 10.33 3164 981 1.18 / 564.46 2 2
5 7 2004.36 32 11.01 3239 1141 2.33 / 565.60 2 2
6 13 1827.60 28 12.48 3023 1056 3.38 / 566.65 2 2
7 13 1032.20 28 13.20 1884 696 4.08 / 567.35 2 2
8 13 244.08 28 14.00 711 279 4.36 / 567.63 2 2
9 8 -0.20 180 14.38 298 771 5.13 / 568.40 2 2
Average= 4.82 (KJ/cycle)

Cycle 116 GMT 13/11/2018 18:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.43 456 184 0.18 / 558.55 2 2
2 12 2006.32 30 10.22 3153 967 1.15 / 559.52 2 2
3 7 2005.84 32 10.98 3236 1137 2.29 / 560.65 2 2
4 13 1665.60 28 12.61 2795 987 3.27 / 561.64 2 2
5 13 924.80 28 13.29 1736 646 3.92 / 562.29 2 2
6 13 179.44 28 14.13 595 235 4.16 / 562.52 2 2
7 8 0.76 180 14.40 289 749 4.91 / 563.27 2 2
Average= 4.81 (KJ/cycle)

Cycle 115 GMT 3/11/2018 17:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 14.43 451 182 0.18 / 553.58 2 2
2 3 970.92 -1 14.43 451 0 0.00 / 553.58 2 2
3 3 1058.88 2 12.17 1905 46 0.23 / 553.63 2 2
4 12 2002.00 30 10.40 3124 975 1.20 / 554.60 2 2
5 7 2001.12 32 11.02 3264 1151 2.35 / 555.75 2 2
6 13 1644.92 28 12.63 2785 985 3.34 / 556.74 2 2
7 13 897.64 28 13.30 1702 634 3.97 / 557.37 2 2
8 13 160.32 28 14.17 562 223 4.20 / 557.59 2 2
9 8 -0.16 180 14.39 299 774 4.97 / 558.37 2 2
Average= 4.81 (KJ/cycle)

Cycle 114 GMT 24/10/2018 17:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 27 14.44 453 177 0.18 / 548.43 2 2
2 3 1022.12 1 9.54 1807 17 0.19 / 548.44 2 2
3 12 2003.20 30 10.45 3132 982 1.18 / 549.43 2 2
4 7 2002.92 32 11.02 3265 1151 2.33 / 550.58 2 2
5 13 1833.52 28 12.48 3046 1064 3.39 / 551.64 2 2
6 13 1038.92 28 13.18 1897 700 4.09 / 552.34 2 2
7 13 249.56 28 14.00 715 280 4.37 / 552.62 2 2
8 8 -0.16 180 14.39 299 774 5.15 / 553.40 2 2
Average= 4.81 (KJ/cycle)

Cycle 113 GMT 14/10/2018 17:38: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 14.43 439 177 0.18 / 543.35 2 2
2 3 941.56 -1 14.43 439 0 0.00 / 543.35 2 2
3 3 1025.60 1 10.47 1853 19 0.20 / 543.37 2 2
4 12 2010.68 30 10.44 3135 982 1.18 / 544.35 2 2
5 7 2010.36 32 11.00 3230 1137 2.32 / 545.49 2 2
6 13 1836.92 28 12.50 3018 1056 3.37 / 546.54 2 2
7 13 867.60 28 13.31 1677 625 4.00 / 547.17 2 2
8 13 281.12 28 13.93 793 309 4.31 / 547.48 2 2
9 8 -0.20 180 14.37 299 773 5.08 / 548.25 2 2
Average= 4.81 (KJ/cycle)

Cycle 112 GMT 4/10/2018 17:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 27 14.44 453 177 0.18 / 538.27 2 2
2 3 1019.08 1 9.62 1812 17 0.19 / 538.29 2 2
3 12 2007.48 30 10.55 3115 986 1.18 / 539.27 2 2
4 7 2006.60 32 11.07 3243 1149 2.33 / 540.42 2 2
5 13 1647.88 28 12.65 2766 980 3.31 / 541.40 2 2
6 13 1065.56 28 13.17 1929 711 4.02 / 542.11 2 2
7 13 264.24 28 13.99 736 288 4.31 / 542.40 2 2
8 8 -0.08 180 14.38 297 769 5.08 / 543.17 2 2
Average= 4.81 (KJ/cycle)

Cycle 111 GMT 24/ 9/2018 17:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 27 14.45 455 178 0.18 / 533.25 2 2
2 12 2002.44 30 10.50 3129 986 1.16 / 534.24 2 2
3 7 2001.68 32 11.00 3252 1145 2.31 / 535.38 2 2
4 13 1844.08 28 12.45 3058 1066 3.37 / 536.45 2 2
5 13 903.60 28 13.31 1701 634 4.01 / 537.08 2 2
6 13 170.20 28 14.15 588 233 4.24 / 537.32 2 2
7 8 -0.12 180 14.38 300 777 5.02 / 538.09 2 2
Average= 4.80 (KJ/cycle)

Cycle 110 GMT 14/ 9/2018 17:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 14.47 447 181 0.18 / 528.10 2 2
2 3 953.20 -1 14.47 447 0 0.00 / 528.10 2 2
3 3 1026.04 1 10.50 1845 19 0.20 / 528.12 2 2
4 12 2002.72 30 10.45 3149 987 1.19 / 529.11 2 2
5 7 2002.00 32 11.04 3244 1146 2.33 / 530.26 2 2
6 13 1649.96 28 12.65 2797 991 3.32 / 531.25 2 2
7 13 1093.60 28 13.15 1983 730 4.05 / 531.98 2 2
8 13 296.32 28 13.92 809 315 4.37 / 532.29 2 2
9 8 -0.12 180 14.37 303 784 5.15 / 533.08 2 2
Average= 4.80 (KJ/cycle)

Cycle 109 GMT 4/ 9/2018 17:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 14.45 446 180 0.18 / 523.06 2 2
2 12 2003.04 30 10.31 3141 972 1.15 / 524.03 2 2
3 7 2001.44 32 11.05 3227 1141 2.29 / 525.17 2 2
4 13 1641.88 28 12.68 2737 972 3.26 / 526.14 2 2
5 13 1049.28 28 13.18 1937 715 3.98 / 526.86 2 2
6 13 239.04 28 14.00 715 280 4.26 / 527.14 2 2
7 8 -0.28 180 14.35 304 785 5.05 / 527.92 2 2
Average= 4.80 (KJ/cycle)

Cycle 108 GMT 25/ 8/2018 17:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 27 14.47 457 179 0.18 / 517.98 2 2
2 12 2000.72 30 10.62 3155 1005 1.18 / 518.99 2 2
3 7 1999.72 32 11.07 3266 1157 2.34 / 520.14 2 2
4 13 1638.00 28 12.69 2766 983 3.32 / 521.13 2 2
5 13 1046.08 28 13.19 1907 704 4.03 / 521.83 2 2
6 13 245.20 28 14.01 717 281 4.31 / 522.11 2 2
7 8 0.48 180 14.37 296 766 5.07 / 522.88 2 2
Average= 4.80 (KJ/cycle)

Cycle 107 GMT 15/ 8/2018 17:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 28 14.48 427 173 0.17 / 512.81 2 2
2 3 928.72 -1 14.48 427 0 0.00 / 512.81 2 2
3 12 2004.92 30 10.59 3155 1002 1.18 / 513.82 2 2
4 7 2004.28 32 11.06 3257 1153 2.33 / 514.97 2 2
5 13 1833.92 28 12.49 3079 1077 3.40 / 516.04 2 2
6 13 1037.48 28 13.20 1904 704 4.11 / 516.75 2 2
7 13 245.64 28 14.01 716 281 4.39 / 517.03 2 2
8 8 -0.16 180 14.37 299 773 5.16 / 517.80 2 2
Average= 4.79 (KJ/cycle)

Cycle 106 GMT 5/ 8/2018 17:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 27 14.43 455 177 0.18 / 507.68 2 2
2 3 1029.20 1 11.10 1865 21 0.20 / 507.70 2 2
3 3 1024.00 1 10.50 1826 19 0.22 / 507.72 2 2
4 12 2005.68 30 10.42 3175 993 1.21 / 508.71 2 2
5 7 2004.12 32 11.12 3228 1149 2.36 / 509.86 2 2
6 13 1634.16 28 12.70 2754 979 3.34 / 510.84 2 2
7 13 867.92 28 13.33 1663 621 3.96 / 511.46 2 2
8 13 260.24 28 13.98 747 292 4.25 / 511.75 2 2
9 13 18.96 28 14.45 325 131 4.38 / 511.88 2 2
10 8 -0.20 180 14.35 293 757 5.14 / 512.64 2 2
Average= 4.79 (KJ/cycle)

Cycle 105 GMT 26/ 7/2018 17:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 14.45 447 174 0.17 / 502.57 2 2
2 12 2004.84 30 10.37 3154 981 1.16 / 503.55 2 2
3 7 2003.80 32 11.08 3221 1142 2.30 / 504.69 2 2
4 13 1829.48 28 12.49 3049 1066 3.36 / 505.76 2 2
5 13 1038.56 28 13.20 1891 699 4.06 / 506.45 2 2
6 13 251.52 28 14.01 714 280 4.34 / 506.73 2 2
7 8 -0.16 180 14.38 296 766 5.11 / 507.50 2 2
Average= 4.79 (KJ/cycle)

Cycle 104 GMT 16/ 7/2018 17:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 27 14.49 440 172 0.17 / 497.61 2 2
2 12 2001.80 30 10.41 3146 982 1.15 / 498.59 2 2
3 7 2000.16 32 11.12 3214 1144 2.30 / 499.74 2 2
4 13 1649.24 28 12.72 2758 982 3.28 / 500.72 2 2
5 13 866.24 28 13.36 1641 614 3.89 / 501.33 2 2
6 13 281.28 28 13.98 760 297 4.19 / 501.63 2 2
7 8 -0.16 180 14.39 294 762 4.95 / 502.39 2 2
Average= 4.78 (KJ/cycle)

Cycle 103 GMT 6/ 7/2018 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 14.51 430 168 0.17 / 492.71 2 2
2 3 950.28 -1 14.51 430 0 0.00 / 492.71 2 2
3 3 1034.60 1 11.73 1865 22 0.19 / 492.73 2 2
4 12 2003.92 30 10.65 3111 994 1.18 / 493.73 2 2
5 7 2002.48 32 11.14 3219 1148 2.33 / 494.87 2 2
6 13 1645.36 28 12.72 2756 982 3.31 / 495.85 2 2
7 13 887.40 28 13.33 1667 622 3.94 / 496.48 2 2
8 13 158.72 28 14.19 548 218 4.15 / 496.69 2 2
9 8 -0.16 180 14.40 287 744 4.90 / 497.44 2 2
Average= 4.78 (KJ/cycle)

Cycle 102 GMT 26/ 6/2018 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 27 14.47 431 168 0.17 / 487.80 2 2
2 12 2003.20 30 10.45 3140 984 1.15 / 488.78 2 2
3 7 2002.52 32 11.14 3232 1152 2.30 / 489.93 2 2
4 13 1650.08 28 12.71 2792 994 3.30 / 490.93 2 2
5 13 893.44 28 13.33 1685 629 3.93 / 491.56 2 2
6 13 162.68 28 14.16 580 230 4.16 / 491.79 2 2
7 8 -0.20 180 14.39 291 754 4.91 / 492.54 2 2
Average= 4.78 (KJ/cycle)

Cycle 101 GMT 16/ 6/2018 17: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 27 14.48 449 176 0.18 / 482.92 2 2
2 12 2003.00 30 10.42 3158 987 1.16 / 483.91 2 2
3 7 2001.60 32 11.14 3238 1154 2.32 / 485.06 2 2
4 13 1485.36 28 12.84 2559 920 3.24 / 485.98 2 2
5 13 738.48 28 13.48 1462 552 3.79 / 486.53 2 2
6 13 177.24 28 14.17 583 231 4.02 / 486.76 2 2
7 13 1.76 28 14.50 301 122 4.14 / 486.89 2 2
8 8 -0.08 180 14.38 287 743 4.89 / 487.63 2 3
Average= 4.78 (KJ/cycle)

Cycle 100 GMT 6/ 6/2018 16:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.50 440 179 0.18 / 477.79 2 2
2 3 943.04 -1 14.50 440 0 0.00 / 477.79 2 2
3 3 1018.96 1 9.96 1833 18 0.20 / 477.80 2 2
4 12 2000.96 30 10.47 3174 997 1.19 / 478.80 2 2
5 7 1999.84 32 11.17 3242 1159 2.35 / 479.96 2 2
6 13 1644.88 28 12.72 2767 985 3.34 / 480.95 2 2
7 13 863.60 28 13.36 1646 616 3.95 / 481.56 2 2
8 13 260.36 28 14.02 737 289 4.24 / 481.85 2 2
9 13 28.60 28 14.43 350 141 4.38 / 481.99 2 2
10 8 -0.20 180 14.38 291 753 5.14 / 482.74 2 3
Average= 4.78 (KJ/cycle)

Cycle 99 GMT 27/ 5/2018 16:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.44 452 183 0.18 / 472.87 2 2
2 12 2011.08 30 10.62 3105 989 1.17 / 473.86 2 2
3 7 2010.52 32 11.15 3225 1151 2.32 / 475.01 2 2
4 13 1657.12 28 12.71 2759 982 3.30 / 476.00 2 2
5 13 875.60 28 13.34 1677 626 3.93 / 476.62 2 2
6 13 158.84 28 14.18 573 228 4.16 / 476.85 2 2
7 8 -0.20 180 14.40 292 757 4.92 / 477.61 2 2
Average= 4.78 (KJ/cycle)

Cycle 98 GMT 17/ 5/2018 16:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 28 14.46 451 183 0.18 / 467.97 2 2
2 12 2004.88 30 10.47 3160 993 1.18 / 468.97 2 2
3 7 2003.32 32 11.19 3216 1152 2.33 / 470.12 2 2
4 13 1631.76 28 12.75 2734 976 3.30 / 471.09 2 2
5 13 884.16 28 13.37 1652 618 3.92 / 471.71 2 2
6 13 146.56 28 14.20 555 221 4.14 / 471.93 2 2
7 8 -0.16 180 14.40 293 759 4.90 / 472.69 2 2
Average= 4.77 (KJ/cycle)

Cycle 97 GMT 7/ 5/2018 16:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 28 14.48 462 187 0.19 / 462.97 2 2
2 12 2001.40 30 10.55 3134 992 1.18 / 463.96 2 2
3 7 2000.04 32 11.17 3234 1156 2.34 / 465.12 2 2
4 13 1632.44 28 12.76 2731 976 3.31 / 466.09 2 2
5 13 1021.00 28 13.25 1868 693 4.00 / 466.78 2 2
6 13 198.36 28 14.11 637 252 4.26 / 467.04 2 2
7 8 -0.28 180 14.39 291 754 5.01 / 467.79 2 2
Average= 4.77 (KJ/cycle)

Cycle 96 GMT 27/ 4/2018 16:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 28 14.44 449 182 0.18 / 457.81 2 2
2 12 2004.16 30 10.48 3156 992 1.17 / 458.80 2 2
3 7 2003.16 32 11.19 3256 1166 2.34 / 459.97 2 2
4 13 1825.32 28 12.59 3020 1065 3.40 / 461.03 2 2
5 13 1023.68 28 13.25 1883 699 4.10 / 461.73 2 2
6 13 230.24 28 14.09 679 268 4.37 / 462.00 2 2
7 8 -0.16 180 14.38 303 784 5.16 / 462.78 2 2
Average= 4.77 (KJ/cycle)

Cycle 95 GMT 17/ 4/2018 16:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 28 14.48 449 182 0.18 / 452.71 2 2
2 12 2006.20 30 10.47 3169 995 1.18 / 453.71 2 2
3 7 2005.52 32 11.20 3257 1167 2.34 / 454.88 2 2
4 13 1829.88 28 12.57 3043 1071 3.42 / 455.95 2 2
5 13 865.12 28 13.38 1658 621 4.04 / 456.57 2 2
6 13 275.24 28 14.00 758 297 4.33 / 456.87 2 2
7 8 -0.28 180 14.39 293 759 5.09 / 457.63 2 2
Average= 4.77 (KJ/cycle)

Cycle 94 GMT 7/ 4/2018 16:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 28 14.44 454 184 0.18 / 447.91 2 2
2 12 2007.44 30 10.57 3149 999 1.18 / 448.91 2 2
3 7 2006.28 32 11.24 3235 1164 2.35 / 450.08 2 2
4 13 1495.08 28 12.90 2523 911 3.26 / 450.99 2 2
5 13 750.72 28 13.50 1491 564 3.82 / 451.55 2 2
6 13 164.28 28 14.18 581 231 4.05 / 451.78 2 2
7 8 -0.20 180 14.39 290 751 4.80 / 452.53 2 2
Average= 4.76 (KJ/cycle)

Cycle 93 GMT 28/ 3/2018 15:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 14.48 449 176 0.18 / 442.75 2 2
2 12 2001.40 30 10.66 3141 1004 1.18 / 443.76 2 2
3 7 2000.36 32 11.25 3251 1170 2.35 / 444.93 2 2
4 13 1825.92 28 12.59 3028 1067 3.42 / 446.00 2 2
5 13 893.44 28 13.37 1686 631 4.05 / 446.63 2 2
6 13 170.48 28 14.21 571 227 4.28 / 446.85 2 2
7 13 15.40 28 14.49 316 128 4.40 / 446.98 2 2
8 8 -0.20 180 14.37 289 748 5.15 / 447.73 2 3
Average= 4.76 (KJ/cycle)

Cycle 92 GMT 18/ 3/2018 15:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 27 14.50 435 170 0.17 / 437.83 2 2
2 12 2005.08 30 10.49 3126 984 1.15 / 438.82 2 2
3 7 2003.72 32 11.18 3270 1170 2.32 / 439.99 2 2
4 13 1639.64 28 12.74 2789 995 3.32 / 440.98 2 2
5 13 876.00 28 13.38 1683 631 3.95 / 441.61 2 2
6 13 148.32 28 14.22 547 218 4.17 / 441.83 2 2
7 8 -0.28 180 14.40 289 749 4.92 / 442.58 2 2
Average= 4.76 (KJ/cycle)

Cycle 91 GMT 8/ 3/2018 15:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 14.52 444 174 0.17 / 432.70 2 2
2 3 955.08 -1 14.52 444 0 0.00 / 432.70 2 2
3 3 1029.76 1 11.29 1851 21 0.19 / 432.72 2 2
4 12 2006.64 30 10.70 3123 1002 1.20 / 433.72 2 2
5 7 2005.44 32 11.23 3277 1178 2.38 / 434.90 2 2
6 13 1643.80 28 12.78 2778 994 3.37 / 435.89 2 2
7 13 1063.48 28 13.24 1928 715 4.08 / 436.61 2 2
8 13 240.08 28 14.04 722 284 4.37 / 436.89 2 2
9 8 -0.40 180 14.38 297 769 5.14 / 437.66 2 2
Average= 4.76 (KJ/cycle)

Cycle 90 GMT 26/ 2/2018 15:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 27 14.50 448 175 0.18 / 427.50 2 2
2 12 2001.32 30 10.65 3133 1001 1.18 / 428.51 2 2
3 7 2000.52 32 11.20 3256 1167 2.34 / 429.67 2 2
4 13 1822.00 28 12.62 3026 1069 3.41 / 430.74 2 2
5 13 851.28 28 13.41 1617 607 4.02 / 431.35 2 2
6 13 257.64 28 14.03 736 289 4.31 / 431.64 2 2
7 13 5.12 28 14.49 310 126 4.43 / 431.76 2 2
8 8 -0.32 180 14.36 295 763 5.20 / 432.53 2 3
Average= 4.75 (KJ/cycle)

Cycle 89 GMT 16/ 2/2018 15:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 27 14.48 438 171 0.17 / 422.52 2 2
2 12 2004.52 30 10.44 3124 978 1.15 / 423.50 2 2
3 7 2003.12 32 11.22 3225 1158 2.31 / 424.65 2 2
4 13 1471.88 28 12.94 2500 906 3.21 / 425.56 2 2
5 13 920.68 28 13.35 1758 657 3.87 / 426.22 2 2
6 13 163.28 28 14.20 580 231 4.10 / 426.45 2 2
7 13 17.28 28 14.50 323 131 4.23 / 426.58 2 2
8 8 -0.24 180 14.38 290 751 4.98 / 427.33 2 2
Average= 4.75 (KJ/cycle)

Cycle 88 GMT 6/ 2/2018 15:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 28 14.53 428 174 0.17 / 417.59 2 2
2 3 942.28 -1 14.53 428 0 0.00 / 417.59 2 2
3 3 1021.68 1 10.32 1827 19 0.19 / 417.61 2 2
4 12 2003.84 30 10.46 3134 983 1.18 / 418.59 2 2
5 7 2002.68 32 11.22 3236 1162 2.34 / 419.75 2 2
6 13 1640.12 28 12.80 2756 988 3.33 / 420.74 2 2
7 13 872.68 28 13.40 1679 630 3.96 / 421.37 2 2
8 13 145.52 28 14.23 555 221 4.18 / 421.59 2 2
9 8 -0.20 180 14.41 291 755 4.93 / 422.35 2 2
Average= 4.75 (KJ/cycle)

Cycle 87 GMT 27/ 1/2018 15:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 28 14.52 455 185 0.18 / 412.92 2 2
2 12 1168.44 1 4.91 1982 10 0.19 / 412.93 2 2
3 12 1958.36 30 10.60 3086 981 1.18 / 413.92 2 2
4 7 1954.96 32 11.22 3163 1136 2.31 / 415.05 2 2
5 13 1583.96 28 12.84 2654 954 3.27 / 416.01 2 2
6 13 614.88 28 13.64 1282 490 3.76 / 416.49 2 2
7 13 107.28 28 14.32 461 185 3.94 / 416.68 2 2
8 8 -0.28 180 14.41 283 734 4.67 / 417.41 2 2
Average= 4.74 (KJ/cycle)

Cycle 86 GMT 17/ 1/2018 13:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 14.54 443 180 0.18 / 408.03 2 2
2 3 963.96 -1 14.54 443 0 0.00 / 408.03 2 2
3 3 1051.52 1 12.80 1911 24 0.20 / 408.05 2 2
4 12 1208.00 1 4.96 2218 11 0.22 / 408.06 2 2
5 12 1959.64 30 10.87 3118 1017 1.23 / 409.08 2 2
6 7 1956.84 32 11.28 3159 1140 2.37 / 410.22 2 2
7 13 1598.36 28 12.82 2712 973 3.35 / 411.20 2 2
8 13 794.04 28 13.49 1544 583 3.93 / 411.78 2 2
9 13 99.16 28 14.34 471 189 4.12 / 411.97 2 2
10 8 -0.20 180 14.39 298 772 4.89 / 412.74 2 2
Average= 4.74 (KJ/cycle)

Cycle 85 GMT 7/ 1/2018 12:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.51 456 185 0.19 / 402.92 2 2
2 12 1155.92 2 7.94 1983 31 0.22 / 402.95 2 2
3 12 1939.64 30 10.81 3149 1021 1.24 / 403.98 2 2
4 7 1937.00 60 11.01 3181 2101 3.34 / 406.08 2 2
5 13 903.88 28 13.35 1733 648 3.99 / 406.72 2 2
6 13 154.80 28 14.22 572 228 4.21 / 406.95 2 2
7 13 10.72 28 14.50 317 129 4.34 / 407.08 2 2
8 8 -0.28 180 14.36 297 768 5.11 / 407.85 2 3
Average= 4.74 (KJ/cycle)

Cycle 84 GMT 28/12/2017 11:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 14.56 447 182 0.18 / 398.02 2 2
2 12 1163.76 2 8.01 1969 32 0.21 / 398.05 2 2
3 12 1941.32 30 10.80 3132 1015 1.23 / 399.06 2 2
4 7 1937.84 60 11.06 3141 2084 3.31 / 401.15 2 2
5 13 754.68 28 13.50 1491 564 3.88 / 401.71 2 2
6 13 181.24 28 14.17 619 246 4.12 / 401.96 2 2
7 8 -0.20 180 14.38 302 782 4.90 / 402.74 2 2
Average= 4.74 (KJ/cycle)

Cycle 83 GMT 18/12/2017 9:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 27 14.58 451 178 0.18 / 393.02 2 2
2 3 1032.92 1 12.26 1898 23 0.20 / 393.04 2 2
3 12 1182.60 2 7.94 1985 32 0.23 / 393.07 2 2
4 12 1939.72 30 10.85 3140 1022 1.25 / 394.10 2 2
5 7 1936.56 60 11.06 3151 2091 3.35 / 396.19 2 2
6 13 909.24 28 13.33 1722 643 3.99 / 396.83 2 2
7 13 159.80 28 14.22 587 234 4.22 / 397.06 2 2
8 8 -0.28 180 14.40 297 770 4.99 / 397.83 2 2
Average= 4.74 (KJ/cycle)

Cycle 82 GMT 8/12/2017 8:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.55 433 176 0.18 / 388.22 2 2
2 3 931.16 -1 14.55 433 0 0.00 / 388.22 2 2
3 12 1182.88 3 10.00 2033 61 0.24 / 388.29 2 2
4 12 1927.56 30 10.92 3129 1025 1.26 / 389.31 2 2
5 7 1924.28 60 11.11 3120 2080 3.34 / 391.39 2 2
6 13 697.00 28 13.56 1398 531 3.87 / 391.92 2 2
7 13 82.28 28 14.38 426 172 4.04 / 392.09 2 2
8 8 -0.16 180 14.41 289 750 4.79 / 392.84 2 2
Average= 4.73 (KJ/cycle)

Cycle 81 GMT 28/11/2017 7:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 28 14.51 456 185 0.19 / 383.36 2 2
2 12 1179.24 3 9.38 2034 57 0.24 / 383.42 2 2
3 12 1925.52 30 10.80 3120 1011 1.25 / 384.43 2 2
4 7 1922.16 60 11.12 3121 2082 3.34 / 386.51 2 2
5 13 710.16 28 13.54 1435 544 3.88 / 387.06 2 2
6 13 160.00 28 14.23 576 230 4.11 / 387.29 2 2
7 8 -0.16 180 14.40 293 759 4.87 / 388.05 2 2
Average= 4.73 (KJ/cycle)

Cycle 80 GMT 18/11/2017 6: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 27 14.55 446 175 0.18 / 378.42 2 2
2 3 1021.64 1 10.34 1830 19 0.19 / 378.43 2 2
3 3 1024.84 1 11.50 1844 21 0.22 / 378.46 2 2
4 7 2005.44 60 10.74 3228 2080 2.30 / 380.54 2 2
5 13 1661.08 28 12.77 2807 1004 3.30 / 381.54 2 2
6 13 921.92 28 13.39 1751 656 3.96 / 382.20 2 2
7 13 172.96 28 14.23 587 234 4.19 / 382.43 2 2
8 8 -0.24 180 14.41 289 750 4.94 / 383.18 2 2
Average= 4.73 (KJ/cycle)

Cycle 79 GMT 8/11/2017 5:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 27 14.55 423 166 0.17 / 373.52 2 2
2 3 952.24 -1 14.55 423 0 0.00 / 373.52 2 2
3 3 1031.28 1 12.18 1877 23 0.19 / 373.54 2 2
4 7 2005.12 60 10.57 3188 2022 2.21 / 375.56 2 2
5 13 1837.72 28 12.60 3043 1074 3.28 / 376.64 2 2
6 13 881.28 28 13.42 1665 626 3.91 / 377.26 2 2
7 13 169.68 28 14.25 568 227 4.14 / 377.49 2 2
8 8 -0.12 180 14.41 290 752 4.89 / 378.24 2 2
Average= 4.73 (KJ/cycle)

Cycle 78 GMT 29/10/2017 5:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 27 14.54 463 182 0.18 / 368.51 2 2
2 7 2005.56 60 10.58 3205 2035 2.22 / 370.54 2 2
3 13 1641.40 28 12.83 2756 990 3.21 / 371.53 2 2
4 13 1090.00 28 13.26 2002 743 3.95 / 372.27 2 2
5 13 286.84 28 14.04 789 310 4.26 / 372.58 2 2
6 8 -0.20 180 14.40 296 767 5.03 / 373.35 2 2
Average= 4.73 (KJ/cycle)

Cycle 77 GMT 19/10/2017 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 26 14.57 441 167 0.17 / 363.39 2 2
2 3 1039.24 1 12.77 1892 24 0.19 / 363.42 2 2
3 7 2003.56 60 10.65 3222 2059 2.25 / 365.48 2 2
4 13 1830.16 28 12.65 3044 1078 3.33 / 366.56 2 2
5 13 1025.04 28 13.32 1892 706 4.03 / 367.26 2 2
6 13 223.80 28 14.12 698 276 4.31 / 367.54 2 2
7 8 -0.32 180 14.38 304 787 5.10 / 368.32 2 2
Average= 4.72 (KJ/cycle)

Cycle 76 GMT 9/10/2017 4:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 27 14.55 445 175 0.17 / 358.42 2 2
2 3 945.16 -1 14.55 445 0 0.00 / 358.42 2 2
3 7 2003.92 60 10.60 3199 2035 2.21 / 360.45 2 2
4 13 1829.04 28 12.65 3025 1071 3.28 / 361.53 2 2
5 13 887.36 28 13.46 1668 629 3.91 / 362.15 2 2
6 13 292.80 28 14.05 789 310 4.22 / 362.46 2 2
7 8 -0.12 180 14.41 294 763 4.98 / 363.23 2 2
Average= 4.72 (KJ/cycle)

Cycle 75 GMT 29/ 9/2017 4:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 27 14.60 471 186 0.19 / 353.53 2 2
2 12 1098.16 3 9.63 1901 55 0.24 / 353.58 2 2
3 7 1841.24 56 11.06 3010 1864 2.10 / 355.45 2 2
4 13 1488.84 43 12.72 2523 1380 3.48 / 356.83 2 2
5 13 433.04 43 13.79 1026 608 4.09 / 357.43 2 2
6 8 -0.20 190 14.38 297 811 4.90 / 358.24 2 3
Average= 4.71 (KJ/cycle)

Cycle 74 GMT 19/ 9/2017 3:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 27 14.60 449 177 0.18 / 348.48 2 2
2 3 962.88 -1 14.60 449 0 0.00 / 348.48 2 2
3 3 1039.24 1 12.83 1902 24 0.20 / 348.51 2 2
4 12 1121.04 3 9.97 1930 58 0.26 / 348.56 2 2
5 7 1834.76 57 11.09 2986 1888 2.15 / 350.45 2 2
6 13 1656.08 43 12.53 2758 1486 3.63 / 351.94 2 2
7 13 367.84 43 13.85 935 557 4.19 / 352.49 2 2
8 8 -0.24 190 14.37 310 846 5.04 / 353.34 2 2
Average= 4.71 (KJ/cycle)

Cycle 73 GMT 9/ 9/2017 2:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 26 14.58 466 177 0.18 / 343.69 2 2
2 3 1023.32 1 12.08 1888 23 0.20 / 343.72 2 2
3 3 1018.72 1 12.07 1881 23 0.22 / 343.74 2 2
4 12 1123.56 3 10.41 1968 61 0.28 / 343.80 2 2
5 7 1836.64 56 11.13 3010 1876 2.16 / 345.68 2 2
6 13 1475.40 43 12.73 2506 1372 3.53 / 347.05 2 2
7 13 270.72 43 14.05 746 451 3.98 / 347.50 2 2
8 8 -0.20 190 14.38 295 806 4.79 / 348.30 2 2
Average= 4.71 (KJ/cycle)

Cycle 72 GMT 30/ 8/2017 1:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 27 14.62 452 178 0.18 / 338.88 2 2
2 3 923.80 -1 14.62 452 0 0.00 / 338.88 2 2
3 12 1115.24 3 10.61 1952 62 0.24 / 338.94 2 2
4 7 1845.64 56 11.18 3013 1886 2.13 / 340.83 2 2
5 13 1488.16 43 12.71 2527 1381 3.51 / 342.21 2 2
6 13 270.96 43 14.02 773 466 3.97 / 342.67 2 2
7 8 -0.20 190 14.37 309 844 4.82 / 343.52 2 2
Average= 4.71 (KJ/cycle)

Cycle 71 GMT 20/ 8/2017 0:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 26 14.64 448 171 0.17 / 334.18 2 2
2 3 1023.48 1 12.58 1890 24 0.19 / 334.20 2 2
3 3 1020.08 1 12.60 1896 24 0.22 / 334.23 2 2
4 12 1111.92 3 11.28 1953 66 0.28 / 334.29 2 2
5 7 1824.96 56 11.27 2995 1890 2.17 / 336.19 2 2
6 13 1300.72 43 12.92 2272 1262 3.44 / 337.45 2 2
7 13 268.28 43 14.06 740 447 3.88 / 337.89 2 2
8 8 -0.36 190 14.39 294 804 4.69 / 338.70 2 3
Average= 4.70 (KJ/cycle)

Cycle 70 GMT 9/ 8/2017 23:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 26 14.59 450 171 0.17 / 329.49 2 2
2 3 968.76 -1 14.59 450 0 0.00 / 329.49 2 2
3 3 1059.32 2 13.23 1938 51 0.22 / 329.54 2 2
4 12 1115.88 3 11.11 1978 66 0.29 / 329.61 2 2
5 7 1825.76 56 11.30 3011 1905 2.19 / 331.52 2 2
6 13 1283.32 43 12.94 2255 1255 3.45 / 332.77 2 2
7 13 252.68 43 14.10 718 435 3.88 / 333.21 2 2
8 8 -0.24 190 14.40 294 804 4.69 / 334.01 2 3
Average= 4.70 (KJ/cycle)

Cycle 69 GMT 30/ 7/2017 22:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 26 14.61 443 168 0.17 / 324.79 2 2
2 12 1104.68 3 10.82 1939 63 0.23 / 324.85 2 2
3 7 1822.00 57 11.26 2988 1918 2.15 / 326.77 2 2
4 13 1305.96 43 12.93 2300 1279 3.43 / 328.05 2 2
5 13 279.44 43 14.06 763 461 3.89 / 328.51 2 2
6 8 -0.28 190 14.38 298 814 4.70 / 329.32 2 4
Average= 4.70 (KJ/cycle)

Cycle 68 GMT 20/ 7/2017 21: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 26 14.63 435 165 0.17 / 319.40 2 2
2 7 2001.96 56 11.01 3226 1989 2.15 / 321.39 2 2
3 13 1651.96 43 12.69 2756 1504 3.66 / 322.89 2 2
4 13 806.44 43 13.48 1558 903 4.56 / 323.79 2 2
5 8 -0.04 190 14.39 302 826 5.39 / 324.62 2 2
Average= 4.70 (KJ/cycle)

Cycle 67 GMT 10/ 7/2017 21:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 26 14.64 456 174 0.17 / 314.00 2 2
2 7 2005.12 56 11.12 3253 2026 2.20 / 316.03 2 2
3 13 1839.52 43 12.51 3050 1641 3.84 / 317.67 2 2
4 13 595.80 43 13.68 1263 743 4.58 / 318.41 2 2
5 8 -0.20 190 14.39 300 820 5.40 / 319.23 2 2
Average= 4.69 (KJ/cycle)

Cycle 66 GMT 30/ 6/2017 21:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 26 14.59 455 173 0.17 / 308.70 2 2
2 3 963.04 -1 14.59 455 0 0.00 / 308.70 2 2
3 3 1040.68 1 13.14 1920 25 0.20 / 308.73 2 2
4 7 2003.64 56 11.25 3225 2032 2.23 / 310.76 2 2
5 13 1649.80 43 12.74 2720 1490 3.72 / 312.25 2 2
6 13 622.24 43 13.66 1306 767 4.49 / 313.01 2 2
7 8 -0.04 190 14.39 298 815 5.30 / 313.83 2 2
Average= 4.68 (KJ/cycle)

Cycle 65 GMT 20/ 6/2017 21:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 26 14.66 441 168 0.17 / 303.18 2 2
2 7 2001.64 56 11.27 3233 2040 2.21 / 305.22 2 2
3 13 1664.48 43 12.73 2771 1517 3.73 / 306.74 2 2
4 13 616.04 43 13.69 1285 756 4.48 / 307.50 2 2
5 13 13.84 43 14.51 331 207 4.69 / 307.70 2 2
6 8 -0.24 190 14.31 303 824 5.51 / 308.53 2 15
Average= 4.67 (KJ/cycle)

Cycle 64 GMT 10/ 6/2017 22: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 26 14.63 431 164 0.16 / 298.01 2 2
2 7 2005.40 56 11.25 3249 2047 2.21 / 300.06 2 2
3 13 1658.52 43 12.75 2768 1518 3.73 / 301.58 2 2
4 13 457.16 43 13.85 1049 625 4.35 / 302.20 2 2
5 8 -0.16 190 14.40 297 813 5.17 / 303.02 2 2
Average= 4.66 (KJ/cycle)

Cycle 63 GMT 31/ 5/2017 21:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 26 14.61 458 174 0.17 / 292.50 2 2
2 7 2023.68 57 11.45 3276 2138 2.31 / 294.64 2 2
3 13 1851.52 43 12.57 3058 1653 3.96 / 296.29 2 2
4 13 566.16 43 13.72 1229 725 4.69 / 297.01 2 2
5 8 -0.28 190 14.37 306 835 5.53 / 297.85 2 2
Average= 4.65 (KJ/cycle)

Cycle 62 GMT 21/ 5/2017 21:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 26 14.64 443 169 0.17 / 287.27 2 2
2 7 2001.64 56 11.54 3233 2089 2.26 / 289.36 2 2
3 13 1644.64 43 12.80 2765 1522 3.78 / 290.88 2 2
4 13 411.60 43 13.89 996 595 4.37 / 291.48 2 2
5 8 -0.36 190 14.37 311 849 5.22 / 292.32 2 2
Average= 4.64 (KJ/cycle)

Cycle 61 GMT 11/ 5/2017 21:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 26 14.68 445 170 0.17 / 281.89 2 2
2 7 2002.84 56 11.59 3255 2113 2.28 / 284.00 2 2
3 13 1640.84 43 12.83 2762 1524 3.81 / 285.52 2 2
4 13 597.16 43 13.72 1268 748 4.55 / 286.27 2 2
5 8 -0.32 190 14.38 304 831 5.38 / 287.10 2 3
Average= 4.63 (KJ/cycle)

Cycle 60 GMT 1/ 5/2017 21:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 26 14.66 443 169 0.17 / 276.59 2 2
2 3 973.28 -1 14.66 443 0 0.00 / 276.59 2 2
3 3 1053.84 1 13.46 1927 26 0.19 / 276.61 2 2
4 7 2000.60 56 11.73 3232 2123 2.32 / 278.74 2 2
5 13 1646.60 43 12.82 2785 1535 3.85 / 280.27 2 2
6 13 433.84 43 13.88 1031 615 4.47 / 280.89 2 2
7 8 -0.36 190 14.38 303 828 5.30 / 281.72 2 4
Average= 4.62 (KJ/cycle)

Cycle 59 GMT 21/ 4/2017 21:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 14.68 446 170 0.17 / 271.43 2 2
2 7 2005.36 47 11.79 3254 1803 1.97 / 273.23 2 2
3 13 1686.28 39 12.89 2804 1410 3.38 / 274.64 2 2
4 13 717.92 39 13.66 1442 768 4.15 / 275.41 2 2
5 13 53.44 39 14.47 389 220 4.37 / 275.63 2 2
6 8 -0.36 190 14.38 289 790 5.16 / 276.42 2 3
Average= 4.61 (KJ/cycle)

Cycle 58 GMT 11/ 4/2017 21: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 26 14.70 449 172 0.17 / 266.10 2 2
2 3 957.40 -1 14.70 449 0 0.00 / 266.10 2 2
3 3 1041.92 1 13.52 1926 26 0.20 / 266.12 2 2
4 7 2008.80 47 11.90 3277 1833 2.03 / 267.96 2 2
5 13 1851.20 39 12.74 3067 1524 3.55 / 269.48 2 2
6 13 680.96 39 13.69 1392 743 4.30 / 270.22 2 2
7 13 52.76 39 14.47 389 220 4.52 / 270.44 2 2
8 8 -0.36 190 14.36 299 816 5.33 / 271.26 2 6
Average= 4.60 (KJ/cycle)

Cycle 57 GMT 1/ 4/2017 20:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 27 14.65 452 179 0.18 / 261.17 2 2
2 3 935.68 -1 14.65 452 0 0.00 / 261.17 2 2
3 7 2007.28 47 11.98 3273 1843 2.02 / 263.02 2 2
4 13 1504.60 39 13.04 2572 1308 3.33 / 264.32 2 2
5 13 447.04 39 13.92 1045 567 3.90 / 264.89 2 2
6 13 40.32 39 14.49 374 211 4.11 / 265.10 2 2
7 8 -0.44 190 14.35 302 823 4.93 / 265.93 2 7
Average= 4.58 (KJ/cycle)

Cycle 56 GMT 22/ 3/2017 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 14.68 444 176 0.18 / 255.80 2 2
2 7 2008.76 47 12.09 3279 1863 2.04 / 257.66 2 2
3 13 1849.48 39 12.77 3090 1539 3.58 / 259.20 2 2
4 13 643.12 39 13.72 1363 729 4.31 / 259.93 2 2
5 13 43.60 39 14.49 391 221 4.53 / 260.15 2 2
6 8 -0.40 190 14.34 309 842 5.37 / 260.99 2 4
Average= 4.58 (KJ/cycle)

Cycle 55 GMT 12/ 3/2017 20: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 27 14.69 467 185 0.19 / 250.87 2 2
2 7 2002.88 47 12.27 3264 1882 2.07 / 252.75 2 2
3 13 1514.56 39 13.09 2569 1312 3.38 / 254.06 2 2
4 13 431.64 39 13.95 1005 547 3.93 / 254.61 2 2
5 13 39.20 39 14.49 368 208 4.13 / 254.81 2 2
6 8 -0.24 190 14.35 297 810 4.94 / 255.62 2 7
Average= 4.56 (KJ/cycle)

Cycle 54 GMT 2/ 3/2017 19:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 27 14.71 456 181 0.18 / 245.43 2 2
2 3 971.56 -1 14.71 456 0 0.00 / 245.43 2 2
3 3 1051.08 1 13.66 1939 26 0.21 / 245.45 2 2
4 7 2006.08 46 12.39 3290 1875 2.08 / 247.33 2 2
5 13 1849.52 39 12.81 3089 1543 3.63 / 248.87 2 2
6 13 666.80 39 13.71 1379 737 4.36 / 249.61 2 2
7 13 39.84 39 14.48 392 221 4.58 / 249.83 2 2
8 8 -0.48 190 14.33 313 852 5.44 / 250.68 2 5
Average= 4.56 (KJ/cycle)

Cycle 53 GMT 20/ 2/2017 19:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 27 14.71 453 180 0.18 / 240.35 2 2
2 3 964.36 -1 14.71 453 0 0.00 / 240.35 2 2
3 3 1052.00 1 13.67 1952 27 0.21 / 240.38 2 2
4 7 2004.56 46 12.47 3267 1874 2.08 / 242.25 2 2
5 13 1516.36 39 13.09 2608 1331 3.41 / 243.58 2 2
6 13 552.72 39 13.82 1197 645 4.06 / 244.23 2 2
7 13 24.48 39 14.53 347 197 4.25 / 244.43 2 2
8 8 -0.44 190 14.34 300 817 5.07 / 245.24 2 7
Average= 4.54 (KJ/cycle)

Cycle 52 GMT 10/ 2/2017 19: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 24 14.73 459 162 0.16 / 235.15 2 2
2 10 1035.44 3 14.09 1911 81 0.24 / 235.23 2 2
3 7 2002.64 46 12.54 3268 1885 2.13 / 237.12 2 2
4 13 1674.08 39 12.99 2820 1429 3.56 / 238.54 2 2
5 13 501.60 39 13.88 1120 606 4.16 / 239.15 2 2
6 13 25.20 39 14.53 348 197 4.36 / 239.35 2 2
7 8 -0.36 190 14.34 303 826 5.19 / 240.17 2 7
Average= 4.53 (KJ/cycle)

Cycle 51 GMT 31/ 1/2017 18:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 26 14.72 440 168 0.17 / 230.44 2 2
2 3 971.48 -1 14.72 440 0 0.00 / 230.44 2 2
3 7 2007.96 46 12.57 3269 1890 2.06 / 232.33 2 2
4 13 1511.80 39 13.12 2581 1321 3.38 / 233.65 2 2
5 13 391.00 39 13.99 955 521 3.90 / 234.17 2 2
6 8 -0.24 190 14.43 298 817 4.72 / 234.99 2 2
Average= 4.52 (KJ/cycle)

Cycle 50 GMT 21/ 1/2017 18:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 27 14.74 446 177 0.18 / 225.51 2 2
2 3 925.52 -1 14.74 446 0 0.00 / 225.51 2 2
3 7 2007.40 46 12.61 3283 1904 2.08 / 227.42 2 2
4 13 1478.28 39 13.14 2541 1302 3.38 / 228.72 2 2
5 13 359.28 39 14.03 920 503 3.89 / 229.22 2 2
6 13 25.84 39 14.52 357 202 4.09 / 229.43 2 2
7 8 -0.48 190 14.34 310 845 4.93 / 230.27 2 11
Average= 4.52 (KJ/cycle)

Cycle 49 GMT 11/ 1/2017 18: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 25 14.71 472 174 0.17 / 220.60 2 2
2 3 1028.60 1 13.79 1927 27 0.20 / 220.63 2 2
3 7 2005.64 47 12.62 3298 1956 2.16 / 222.58 2 2
4 13 1379.68 37 13.21 2419 1182 3.34 / 223.76 2 2
5 13 439.52 37 13.95 1038 536 3.87 / 224.30 2 2
6 13 19.68 37 14.53 351 189 4.06 / 224.49 2 2
7 8 0.04 190 14.34 311 847 4.91 / 225.34 2 8
Average= 4.51 (KJ/cycle)

Cycle 48 GMT 1/ 1/2017 17:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 25 14.76 444 164 0.16 / 215.59 2 2
2 7 2005.16 46 12.60 3263 1891 2.06 / 217.48 2 2
3 13 1504.60 37 13.13 2574 1250 3.31 / 218.73 2 2
4 13 540.72 37 13.83 1212 620 3.93 / 219.35 2 2
5 13 24.80 37 14.52 370 199 4.12 / 219.55 2 2
6 8 -0.44 190 14.33 320 871 5.00 / 220.42 2 6
Average= 4.50 (KJ/cycle)

Cycle 47 GMT 22/12/2016 16:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 25 14.75 437 161 0.16 / 210.78 2 2
2 7 2002.92 46 12.49 3258 1872 2.03 / 212.65 2 2
3 13 1518.12 37 13.11 2586 1254 3.29 / 213.90 2 2
4 13 436.76 37 13.94 1027 530 3.82 / 214.43 2 2
5 13 19.76 37 14.56 336 181 4.00 / 214.62 2 2
6 8 -0.28 190 14.37 298 814 4.81 / 215.43 2 7
Average= 4.49 (KJ/cycle)

Cycle 46 GMT 12/12/2016 16: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 26 14.75 450 173 0.17 / 205.98 2 2
2 3 941.40 -1 14.75 450 0 0.00 / 205.98 2 2
3 7 2002.36 46 12.49 3267 1877 2.05 / 207.85 2 2
4 13 1523.52 37 13.12 2581 1253 3.30 / 209.11 2 2
5 13 415.76 37 13.99 986 510 3.81 / 209.62 2 2
6 13 22.52 37 14.56 344 185 4.00 / 209.80 2 2
7 8 -0.24 190 14.38 298 814 4.81 / 210.62 2 4
Average= 4.48 (KJ/cycle)

Cycle 45 GMT 2/12/2016 15:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 26 14.77 454 174 0.17 / 201.10 2 2
2 7 2003.56 47 12.54 3254 1918 2.09 / 203.01 2 2
3 13 1495.28 37 13.14 2531 1231 3.32 / 204.24 2 2
4 13 412.68 37 13.98 1010 522 3.85 / 204.77 2 2
5 13 37.80 37 14.54 378 203 4.05 / 204.97 2 2
6 8 -0.24 190 14.37 306 835 4.88 / 205.81 2 6
Average= 4.47 (KJ/cycle)

Cycle 44 GMT 22/11/2016 14:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 25 14.78 465 172 0.17 / 195.88 2 2
2 3 1029.48 1 13.97 1926 27 0.20 / 195.91 2 2
3 7 2005.16 46 12.53 3273 1886 2.09 / 197.80 2 2
4 13 1853.64 37 12.88 3053 1455 3.54 / 199.25 2 2
5 13 660.28 37 13.77 1341 683 4.22 / 199.94 2 2
6 13 25.00 37 14.57 342 184 4.41 / 200.12 2 2
7 8 -0.36 190 14.39 293 801 5.21 / 200.92 2 6
Average= 4.46 (KJ/cycle)

Cycle 43 GMT 12/11/2016 14:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 26 14.76 451 173 0.17 / 190.76 2 2
2 3 931.28 -1 14.76 451 0 0.00 / 190.76 2 2
3 7 2003.40 46 12.54 3277 1890 2.06 / 192.65 2 2
4 13 1533.92 37 13.13 2626 1276 3.34 / 193.92 2 2
5 13 735.24 37 13.70 1485 753 4.09 / 194.68 2 2
6 13 23.32 37 14.57 347 187 4.28 / 194.86 2 2
7 8 -0.28 190 14.37 311 849 5.13 / 195.71 2 4
Average= 4.45 (KJ/cycle)

Cycle 42 GMT 2/11/2016 14:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 26 14.79 441 170 0.17 / 185.75 2 2
2 3 1024.16 1 13.90 1915 27 0.20 / 185.77 2 2
3 7 2003.56 47 12.60 3279 1942 2.14 / 187.71 2 2
4 13 1482.84 37 13.17 2540 1238 3.38 / 188.95 2 2
5 13 523.00 37 13.91 1147 590 3.97 / 189.54 2 2
6 13 8.52 37 14.59 337 182 4.15 / 189.72 2 2
7 8 -0.40 190 14.36 315 859 5.01 / 190.58 2 6
Average= 4.43 (KJ/cycle)

Cycle 41 GMT 23/10/2016 13:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 26 14.78 444 171 0.17 / 180.96 2 2
2 7 2001.24 46 12.62 3276 1902 2.07 / 182.86 2 2
3 13 1664.40 37 13.08 2777 1344 3.42 / 184.21 2 2
4 13 518.80 37 13.93 1143 589 4.01 / 184.80 2 2
5 8 -0.20 190 14.47 284 781 4.79 / 185.58 2 3
Average= 4.42 (KJ/cycle)

Cycle 40 GMT 13/10/2016 13: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 26 14.79 455 175 0.17 / 176.12 2 2
2 3 969.68 -1 14.79 455 0 0.00 / 176.12 2 2
3 3 1053.60 1 13.92 1939 27 0.20 / 176.14 2 2
4 7 2004.20 46 12.66 3259 1898 2.10 / 178.04 2 2
5 13 1682.88 37 13.09 2802 1357 3.46 / 179.40 2 2
6 13 495.24 37 13.96 1102 569 4.03 / 179.97 2 2
7 8 -0.12 190 14.46 299 821 4.85 / 180.79 2 2
Average= 4.41 (KJ/cycle)

Cycle 39 GMT 3/10/2016 12:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 26 14.79 462 178 0.18 / 171.37 2 2
2 3 951.36 -1 14.79 462 0 0.00 / 171.37 2 2
3 3 1027.72 1 13.70 1908 26 0.20 / 171.39 2 2
4 7 2008.00 46 12.64 3285 1910 2.11 / 173.30 2 2
5 13 1531.00 37 13.17 2627 1280 3.39 / 174.58 2 2
6 13 421.40 37 14.04 1006 523 3.92 / 175.11 2 2
7 8 -0.08 190 14.48 304 836 4.75 / 175.94 2 2
Average= 4.40 (KJ/cycle)

Cycle 38 GMT 23/ 9/2016 11:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 26 14.77 483 185 0.19 / 166.66 2 2
2 3 1019.68 1 13.93 1926 27 0.21 / 166.68 2 2
3 7 2001.48 46 12.64 3285 1910 2.12 / 168.59 2 2
4 13 1362.56 37 13.27 2401 1179 3.30 / 169.77 2 2
5 13 452.76 37 14.00 1079 559 3.86 / 170.33 2 2
6 8 -0.24 190 14.46 313 860 4.72 / 171.19 2 2
Average= 4.39 (KJ/cycle)

Cycle 37 GMT 13/ 9/2016 10:14:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 26 14.79 447 172 0.17 / 161.91 2 2
2 3 964.04 -1 14.79 447 0 0.00 / 161.91 2 2
3 3 1046.16 1 13.91 1948 27 0.20 / 161.93 2 2
4 7 2002.84 46 12.68 3276 1911 2.11 / 163.84 2 2
5 13 1348.88 37 13.29 2384 1172 3.28 / 165.02 2 2
6 13 436.40 37 14.02 1053 546 3.83 / 165.56 2 2
7 8 -0.16 190 14.42 331 907 4.74 / 166.47 2 2
Average= 4.38 (KJ/cycle)

Cycle 36 GMT 3/ 9/2016 9:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 26 14.78 459 176 0.18 / 157.05 2 2
2 3 968.64 -1 14.78 459 0 0.00 / 157.05 2 2
3 3 1045.84 1 13.99 1939 27 0.20 / 157.08 2 2
4 7 2005.76 46 12.73 3261 1910 2.11 / 158.99 2 2
5 13 1511.72 37 13.22 2580 1262 3.38 / 160.25 2 2
6 13 567.56 37 13.92 1232 635 4.01 / 160.89 2 2
7 8 0.00 190 14.46 309 849 4.86 / 161.73 2 2
Average= 4.37 (KJ/cycle)

Cycle 35 GMT 24/ 8/2016 8:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 26 14.82 477 184 0.18 / 152.32 2 2
2 7 2003.80 46 12.81 3293 1940 2.12 / 154.26 2 2
3 13 1372.92 37 13.34 2402 1186 3.31 / 155.45 2 2
4 13 451.76 37 14.04 1068 555 3.86 / 156.00 2 2
5 8 -0.32 190 14.44 318 872 4.74 / 156.88 2 2
Average= 4.36 (KJ/cycle)

Cycle 34 GMT 14/ 8/2016 8:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 26 14.81 474 183 0.18 / 147.38 2 2
2 7 2002.92 46 12.84 3269 1931 2.11 / 149.31 2 2
3 13 1665.64 37 13.18 2812 1371 3.48 / 150.69 2 2
4 13 488.72 37 14.00 1129 585 4.07 / 151.27 2 2
5 8 -0.16 190 14.47 316 869 4.94 / 152.14 2 2
Average= 4.35 (KJ/cycle)

Cycle 33 GMT 4/ 8/2016 7:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 25 14.82 471 175 0.17 / 142.43 2 2
2 7 2004.08 46 12.91 3301 1960 2.13 / 144.39 2 2
3 13 1512.00 37 13.29 2601 1279 3.41 / 145.67 2 2
4 13 552.08 37 13.97 1210 625 4.04 / 146.30 2 2
5 8 -0.28 190 14.46 329 904 4.94 / 147.20 2 2
Average= 4.33 (KJ/cycle)

Cycle 32 GMT 25/ 7/2016 7:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 26 14.82 451 174 0.17 / 137.60 2 2
2 3 953.84 -1 14.82 451 0 0.00 / 137.60 2 2
3 3 1034.12 1 14.11 1941 27 0.20 / 137.63 2 2
4 7 2004.04 46 12.95 3290 1960 2.16 / 139.59 2 2
5 13 1511.28 37 13.29 2611 1284 3.44 / 140.87 2 2
6 13 402.80 37 14.12 989 517 3.96 / 141.39 2 2
7 8 -0.24 190 14.46 317 871 4.83 / 142.26 2 2
Average= 4.31 (KJ/cycle)

Cycle 31 GMT 15/ 7/2016 6:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 26 14.80 491 189 0.19 / 132.45 2 2
2 7 2003.28 46 13.00 3282 1963 2.15 / 134.41 2 2
3 13 1668.20 37 13.23 2788 1365 3.52 / 135.78 2 2
4 13 519.84 37 14.03 1154 599 4.12 / 136.38 2 2
5 13 26.80 37 14.64 364 197 4.31 / 136.57 2 2
6 8 -0.28 190 14.44 310 851 5.16 / 137.43 2 9
Average= 4.29 (KJ/cycle)

Cycle 30 GMT 5/ 7/2016 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 25 14.83 470 174 0.17 / 127.50 2 2
2 3 1023.32 1 14.29 1942 28 0.20 / 127.53 2 2
3 7 2004.32 47 13.03 3278 2007 2.21 / 129.54 2 2
4 13 1514.76 37 13.31 2611 1286 3.50 / 130.82 2 2
5 13 383.52 37 14.15 971 508 4.00 / 131.33 2 2
6 8 -0.32 190 14.43 340 932 4.94 / 132.26 2 2
Average= 4.27 (KJ/cycle)

Cycle 29 GMT 25/ 6/2016 5:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 25 14.82 452 167 0.17 / 122.72 2 2
2 3 965.00 -1 14.82 452 0 0.00 / 122.72 2 2
3 3 1032.84 1 14.22 1944 28 0.20 / 122.74 2 2
4 7 2003.44 46 13.01 3288 1968 2.16 / 124.71 2 2
5 13 1504.60 37 13.33 2574 1270 3.43 / 125.98 2 2
6 13 372.00 37 14.16 948 497 3.93 / 126.48 2 2
7 8 -0.28 190 14.49 308 848 4.78 / 127.33 2 2
Average= 4.24 (KJ/cycle)

Cycle 28 GMT 15/ 6/2016 4:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 25 14.81 436 161 0.16 / 117.78 2 2
2 7 2003.84 46 13.03 3265 1957 2.12 / 119.74 2 2
3 13 1497.92 37 13.33 2568 1267 3.38 / 121.00 2 2
4 13 365.56 37 14.17 944 495 3.88 / 121.50 2 2
5 13 16.64 37 14.68 341 185 4.07 / 121.68 2 2
6 8 0.28 190 14.41 316 865 4.93 / 122.55 2 9
Average= 4.23 (KJ/cycle)

Cycle 27 GMT 5/ 6/2016 4:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 25 14.86 413 153 0.15 / 112.99 2 2
2 7 2003.48 47 13.05 3259 1999 2.15 / 114.99 2 2
3 13 1488.80 37 13.35 2515 1242 3.39 / 116.23 2 2
4 13 498.04 37 14.07 1103 574 3.97 / 116.81 2 2
5 8 -0.16 190 14.51 294 811 4.78 / 117.62 2 2
Average= 4.20 (KJ/cycle)

Cycle 26 GMT 26/ 5/2016 3:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 25 14.89 403 150 0.15 / 108.30 2 2
2 7 2003.48 47 13.04 3256 1996 2.15 / 110.30 2 2
3 13 1344.28 36 13.45 2316 1121 3.27 / 111.42 2 2
4 13 414.04 36 14.17 966 493 3.76 / 111.91 2 2
5 13 31.56 36 14.68 324 171 3.93 / 112.09 2 2
6 8 -0.28 190 14.49 274 754 4.69 / 112.84 2 7
Average= 4.18 (KJ/cycle)

Cycle 25 GMT 16/ 5/2016 2:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 25 14.90 391 146 0.15 / 103.77 2 2
2 3 968.80 -1 14.90 391 0 0.00 / 103.77 2 2
3 3 1053.88 1 14.41 1940 28 0.17 / 103.80 2 2
4 7 2001.40 46 13.05 3231 1940 2.11 / 105.74 2 2
5 13 1495.84 36 13.38 2523 1215 3.33 / 106.96 2 2
6 13 372.56 36 14.23 894 458 3.79 / 107.41 2 2
7 8 -0.16 190 14.58 267 740 4.53 / 108.15 2 2
Average= 4.16 (KJ/cycle)

Cycle 24 GMT 6/ 5/2016 2:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 25 14.89 392 146 0.15 / 99.07 2 2
2 7 2005.52 46 13.06 3246 1950 2.10 / 101.02 2 2
3 13 1499.36 36 13.37 2539 1222 3.32 / 102.24 2 2
4 13 390.72 36 14.20 924 472 3.79 / 102.71 2 2
5 13 32.40 36 14.70 321 170 3.96 / 102.88 2 2
6 8 -0.36 190 14.51 270 744 4.70 / 103.63 2 6
Average= 4.15 (KJ/cycle)

Cycle 23 GMT 26/ 4/2016 1:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 25 14.93 398 149 0.15 / 94.44 2 2
2 7 2002.16 46 13.07 3244 1950 2.10 / 96.39 2 2
3 13 1483.56 36 13.41 2478 1196 3.30 / 97.59 2 2
4 13 373.76 36 14.24 890 456 3.75 / 98.04 2 2
5 13 3.00 36 14.79 271 144 3.90 / 98.19 2 2
6 8 -0.36 190 14.52 267 737 4.63 / 98.92 2 4
Average= 4.12 (KJ/cycle)

Cycle 22 GMT 16/ 4/2016 0:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 25 14.92 394 147 0.15 / 89.93 2 2
2 3 970.04 -1 14.92 394 0 0.00 / 89.93 2 2
3 3 1048.36 1 14.47 1932 28 0.17 / 89.96 2 2
4 7 2002.56 50 13.05 3237 2112 2.29 / 92.07 2 2
5 13 1333.88 25 13.64 2314 789 3.08 / 92.86 2 2
6 13 798.04 25 14.01 1524 534 3.61 / 93.39 2 2
7 13 109.24 25 14.67 450 165 3.77 / 93.56 2 2
8 8 -0.20 190 14.60 264 732 4.51 / 94.29 2 2
Average= 4.10 (KJ/cycle)

Cycle 21 GMT 6/ 4/2016 0:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 25 14.91 413 154 0.15 / 85.50 2 2
2 7 2008.68 50 13.06 3261 2129 2.28 / 87.63 2 2
3 13 1342.44 25 13.65 2326 794 3.08 / 88.42 2 2
4 13 621.32 25 14.13 1273 450 3.53 / 88.87 2 2
5 13 107.60 25 14.65 448 164 3.69 / 89.04 2 2
6 8 -0.28 190 14.59 269 746 4.44 / 89.78 2 3
Average= 4.08 (KJ/cycle)

Cycle 20 GMT 26/ 3/2016 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 25 14.92 403 150 0.15 / 81.15 2 2
2 7 2005.40 50 13.10 3227 2114 2.26 / 83.26 2 2
3 13 1300.60 25 13.68 2250 769 3.03 / 84.03 2 2
4 13 596.32 25 14.16 1232 436 3.47 / 84.47 2 2
5 13 59.56 25 14.75 369 136 3.61 / 84.60 2 2
6 8 -0.32 190 14.58 269 745 4.35 / 85.35 2 2
Average= 4.06 (KJ/cycle)

Cycle 19 GMT 16/ 3/2016 21:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 25 14.92 410 153 0.15 / 76.79 2 2
2 7 2002.00 50 13.11 3254 2133 2.29 / 78.92 2 2
3 13 1293.72 25 13.70 2252 771 3.06 / 79.70 2 2
4 13 575.16 25 14.18 1201 426 3.48 / 80.12 2 2
5 13 59.40 25 14.78 364 134 3.62 / 80.26 2 2
6 8 -0.20 190 14.60 267 741 4.36 / 81.00 2 2
Average= 4.05 (KJ/cycle)

Cycle 18 GMT 6/ 3/2016 21: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 14.95 413 154 0.15 / 72.30 2 2
2 7 2003.04 51 13.13 3222 2158 2.31 / 74.46 2 2
3 13 1477.40 25 13.60 2514 855 3.17 / 75.31 2 2
4 13 572.08 25 14.18 1196 424 3.59 / 75.74 2 2
5 13 89.92 25 14.72 419 154 3.74 / 75.89 2 2
6 8 -0.28 190 14.58 270 748 4.49 / 76.64 2 2
Average= 4.03 (KJ/cycle)

Cycle 17 GMT 25/ 2/2016 20: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 25 14.95 415 155 0.16 / 67.90 2 2
2 7 2007.08 51 13.13 3232 2164 2.32 / 70.07 2 2
3 13 1294.80 25 13.71 2251 772 3.09 / 70.84 2 2
4 13 591.92 25 14.18 1228 435 3.53 / 71.27 2 2
5 13 58.52 25 14.79 364 135 3.66 / 71.41 2 2
6 8 -0.28 190 14.61 266 738 4.40 / 72.15 2 2
Average= 4.01 (KJ/cycle)

Cycle 16 GMT 15/ 2/2016 19: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 25 14.93 400 149 0.15 / 63.43 2 2
2 3 970.24 -1 14.93 400 0 0.00 / 63.43 2 2
3 3 1044.68 1 14.61 1915 28 0.18 / 63.46 2 2
4 7 2004.40 50 13.13 3226 2118 2.30 / 65.57 2 2
5 13 1179.12 25 13.77 2087 718 3.01 / 66.29 2 2
6 13 819.20 25 14.02 1558 546 3.56 / 66.84 2 2
7 13 97.20 25 14.73 431 159 3.72 / 67.00 2 2
8 8 -0.44 190 14.60 270 749 4.47 / 67.75 2 2
Average= 3.99 (KJ/cycle)

Cycle 15 GMT 5/ 2/2016 18:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 25 14.96 424 159 0.16 / 59.06 2 2
2 7 2001.24 50 13.15 3228 2122 2.28 / 61.18 2 2
3 13 1332.08 25 13.70 2278 780 3.06 / 61.96 2 2
4 13 611.36 25 14.17 1249 442 3.50 / 62.40 2 2
5 13 52.20 25 14.80 353 131 3.63 / 62.54 2 2
6 8 -0.24 190 14.60 268 743 4.38 / 63.28 2 2
Average= 3.95 (KJ/cycle)

Cycle 14 GMT 26/ 1/2016 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 24 14.98 410 147 0.15 / 54.67 2 2
2 7 2002.32 51 13.15 3244 2176 2.32 / 56.85 2 2
3 13 1294.24 25 13.70 2252 771 3.09 / 57.62 2 2
4 13 546.96 25 14.20 1168 415 3.51 / 58.03 2 2
5 13 51.20 25 14.82 350 130 3.64 / 58.16 2 2
6 8 -0.24 190 14.62 266 739 4.38 / 58.90 2 2
Average= 3.93 (KJ/cycle)

Cycle 13 GMT 16/ 1/2016 16: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 24 14.98 395 142 0.14 / 50.34 2 2
2 3 962.36 -1 14.98 395 0 0.00 / 50.34 2 2
3 3 1042.88 1 14.65 1917 28 0.17 / 50.37 2 2
4 7 2008.52 50 13.16 3248 2137 2.31 / 52.51 2 2
5 13 1307.40 25 13.71 2279 781 3.09 / 53.29 2 2
6 13 449.96 25 14.29 1013 362 3.45 / 53.65 2 2
7 13 59.68 25 14.80 368 136 3.59 / 53.79 2 2
8 8 -0.32 190 14.61 265 736 4.32 / 54.52 2 2
Average= 3.89 (KJ/cycle)

Cycle 12 GMT 6/ 1/2016 14:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 24 15.00 400 144 0.14 / 46.02 2 2
2 7 2002.28 50 13.16 3227 2123 2.27 / 48.15 2 2
3 13 1288.28 25 13.72 2238 768 3.03 / 48.91 2 2
4 13 562.28 25 14.20 1187 421 3.46 / 49.33 2 2
5 13 53.60 25 14.85 351 130 3.59 / 49.47 2 2
6 8 -0.12 190 14.63 265 737 4.32 / 50.20 2 2
Average= 3.86 (KJ/cycle)

Cycle 11 GMT 27/12/2015 13:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 24 14.99 410 148 0.15 / 41.63 2 2
2 7 2005.20 51 13.17 3233 2172 2.32 / 43.81 2 2
3 13 1367.64 25 13.67 2354 804 3.12 / 44.61 2 2
4 13 484.12 25 14.27 1070 382 3.51 / 44.99 2 2
5 13 64.76 25 14.82 376 139 3.64 / 45.13 2 2
6 8 -0.28 190 14.62 269 747 4.39 / 45.88 2 2
Average= 3.82 (KJ/cycle)

Cycle 10 GMT 17/12/2015 12:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 24 14.99 416 150 0.15 / 37.31 2 2
2 7 2004.00 50 13.17 3228 2126 2.28 / 39.44 2 2
3 13 1361.96 25 13.67 2346 802 3.08 / 40.24 2 2
4 13 461.76 25 14.29 1035 370 3.45 / 40.61 2 2
5 13 57.92 25 14.83 364 135 3.58 / 40.74 2 2
6 8 -0.28 190 14.62 267 742 4.32 / 41.49 2 2
Average= 3.77 (KJ/cycle)

Cycle 9 GMT 7/12/2015 11: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 24 15.00 411 148 0.15 / 33.02 2 2
2 7 2002.48 50 13.18 3222 2123 2.27 / 35.15 2 2
3 13 1186.32 25 13.77 2101 723 2.99 / 35.87 2 2
4 13 523.60 25 14.22 1131 402 3.40 / 36.27 2 2
5 13 65.88 25 14.82 382 142 3.54 / 36.41 2 2
6 8 -0.24 190 14.60 270 749 4.29 / 37.16 2 2
Average= 3.72 (KJ/cycle)

Cycle 8 GMT 27/11/2015 9:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 24 15.00 408 147 0.15 / 28.72 2 2
2 7 2005.16 50 13.17 3218 2119 2.27 / 30.84 2 2
3 13 1336.40 25 13.66 2307 788 3.05 / 31.63 2 2
4 13 467.20 25 14.28 1036 370 3.42 / 32.00 2 2
5 13 60.24 25 14.84 367 136 3.56 / 32.13 2 2
6 8 -0.24 190 14.63 267 742 4.30 / 32.88 2 2
Average= 3.65 (KJ/cycle)

Cycle 7 GMT 17/11/2015 7:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 24 15.01 412 148 0.15 / 24.43 2 2
2 7 2001.92 50 13.15 3224 2120 2.27 / 26.55 2 2
3 13 1343.52 25 13.65 2310 788 3.06 / 27.34 2 2
4 13 455.44 25 14.28 1019 364 3.42 / 27.71 2 2
5 13 49.96 25 14.85 350 130 3.55 / 27.84 2 2
6 8 -0.20 190 14.61 266 738 4.29 / 28.57 2 2
Average= 3.57 (KJ/cycle)

Cycle 6 GMT 7/11/2015 5:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 23 14.95 407 140 0.14 / 20.22 2 2
2 7 1995.72 50 13.14 3210 2109 2.25 / 22.33 2 2
3 13 1145.08 25 13.75 2029 697 2.95 / 23.03 2 2
4 13 496.48 25 14.23 1082 385 3.33 / 23.41 2 2
5 13 61.32 25 14.83 365 135 3.47 / 23.55 2 2
6 8 -0.16 190 14.61 266 738 4.21 / 24.29 2 2
Average= 3.47 (KJ/cycle)

Cycle 5 GMT 28/10/2015 3:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 25 14.92 416 155 0.16 / 16.03 2 2
2 3 928.92 -1 14.92 416 0 0.00 / 16.03 2 2
3 7 1983.80 50 13.12 3186 2090 2.25 / 18.12 2 2
4 13 1307.28 25 13.65 2224 759 3.00 / 18.88 2 2
5 13 424.60 25 14.31 967 346 3.35 / 19.23 2 2
6 13 48.28 25 14.86 337 125 3.48 / 19.35 2 2
7 8 -0.08 190 14.59 263 729 4.20 / 20.08 2 3
Average= 3.35 (KJ/cycle)

Cycle 4 GMT 18/10/2015 2: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 24 14.91 414 148 0.15 / 12.49 2 2
2 3 968.04 -1 14.91 414 0 0.00 / 12.49 2 2
3 3 1050.04 1 14.62 1934 28 0.18 / 12.51 2 2
4 7 1502.56 50 13.42 2514 1687 1.86 / 14.20 2 2
5 13 929.12 25 13.86 1701 589 2.45 / 14.79 2 2
6 13 279.68 25 14.46 728 263 2.72 / 15.05 2 2
7 13 23.32 25 14.87 298 111 2.83 / 15.17 2 2
8 8 -0.08 190 14.56 257 711 3.54 / 15.88 2 4
Average= 3.18 (KJ/cycle)

Cycle 3 GMT 17/10/2015 2:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 24 14.89 410 147 0.15 / 8.49 2 2
2 3 964.40 -1 14.89 410 0 0.00 / 8.49 2 2
3 3 1044.12 1 14.61 1901 28 0.17 / 8.51 2 2
4 7 1504.76 74 13.21 2507 2451 2.62 / 10.96 2 2
5 13 521.60 20 14.20 1112 316 2.94 / 11.28 2 2
6 13 150.08 20 14.65 510 149 3.09 / 11.43 2 2
7 8 -0.08 240 14.52 261 910 4.00 / 12.34 2 23
Average= 3.08 (KJ/cycle)

Cycle 2 GMT 16/10/2015 2:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 25 14.79 408 151 0.15 / 4.42 2 2
2 3 920.44 -2 14.79 408 0 0.00 / 4.42 2 2
3 3 1067.92 2 14.54 1925 56 0.21 / 4.48 2 2
4 7 1504.32 75 13.13 2468 2430 2.64 / 6.91 2 2
5 13 732.04 20 14.00 1412 395 3.03 / 7.31 2 2
6 13 132.48 20 14.64 473 138 3.17 / 7.44 2 2
7 8 0.08 240 14.51 257 895 4.07 / 8.34 2 27
Average= 2.78 (KJ/cycle)

Cycle 1 GMT 15/10/2015 3:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 25 14.92 380 142 0.14 / 1.45 2 2
2 3 896.72 -2 14.92 380 0 0.00 / 1.45 2 2
3 3 1043.00 1 14.23 1892 27 0.17 / 1.48 2 2
4 7 1027.16 75 13.28 1815 1808 1.98 / 3.29 2 2
5 13 38.28 20 14.71 319 94 2.07 / 3.38 2 2
6 8 -0.32 240 14.43 257 890 2.96 / 4.27 2 51
Average= 2.14 (KJ/cycle)

Cycle 0 GMT 14/10/2015 16: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 24 14.68 384 135 0.14 / 0.14 2 2
2 7 116.08 74 14.54 389 419 0.55 / 0.55 2 2
3 8 0.20 240 14.77 214 759 1.31 / 1.31 2 32
Average= 1.31 (KJ/cycle)