SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 40 | 10.75 | 366 | 157 | 0.16 / 1421.77 | 2 | 2 |
2 | 12 | 1093.76 | 5 | 6.84 | 1764 | 60 | 0.22 / 1421.83 | 2 | 2 |
3 | 12 | 1142.44 | 200 | 6.61 | 1855 | 2452 | 2.67 / 1424.28 | 2 | 2 |
4 | 12 | 1135.40 | 125 | 6.30 | 1827 | 1439 | 4.11 / 1425.72 | 2 | 2 |
5 | 7 | 1098.28 | 30 | 6.30 | 1783 | 337 | 4.45 / 1426.06 | 2 | 2 |
6 | 8 | -0.16 | 180 | 10.74 | 251 | 485 | 4.93 / 1426.54 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 43 | 10.78 | 388 | 180 | 0.18 / 1416.69 | 2 | 2 |
2 | 3 | 926.20 | -1 | 10.78 | 388 | 0 | 0.00 / 1416.69 | 2 | 2 |
3 | 3 | 1046.32 | 2 | 7.50 | 1746 | 26 | 0.21 / 1416.71 | 2 | 2 |
4 | 12 | 1120.04 | 5 | 6.88 | 1823 | 63 | 0.27 / 1416.78 | 2 | 2 |
5 | 12 | 1148.24 | 200 | 6.75 | 1877 | 2534 | 2.80 / 1419.31 | 2 | 2 |
6 | 12 | 1139.20 | 125 | 6.38 | 1827 | 1457 | 4.26 / 1420.77 | 2 | 2 |
7 | 7 | 1099.40 | 30 | 6.43 | 1789 | 345 | 4.60 / 1421.11 | 2 | 2 |
8 | 8 | -0.16 | 180 | 10.77 | 257 | 498 | 5.10 / 1421.61 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 36 | 10.81 | 404 | 157 | 0.16 / 1411.26 | 2 | 2 |
2 | 10 | 1023.36 | 4 | 8.45 | 1752 | 59 | 0.22 / 1411.32 | 2 | 2 |
3 | 3 | 1067.56 | 3 | 8.21 | 1819 | 45 | 0.26 / 1411.37 | 2 | 2 |
4 | 12 | 1106.08 | 5 | 7.60 | 1807 | 69 | 0.33 / 1411.43 | 2 | 2 |
5 | 12 | 1151.56 | 200 | 7.04 | 1903 | 2679 | 3.01 / 1414.11 | 2 | 2 |
6 | 12 | 1145.04 | 125 | 6.56 | 1862 | 1527 | 4.54 / 1415.64 | 2 | 2 |
7 | 7 | 1107.92 | 30 | 6.52 | 1820 | 356 | 4.89 / 1416.00 | 2 | 2 |
8 | 8 | 0.16 | 180 | 10.79 | 263 | 511 | 5.40 / 1416.51 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 32 | 10.99 | 417 | 147 | 0.15 / 1401.99 | 2 | 2 |
2 | 10 | 1023.76 | 6 | 8.44 | 1741 | 88 | 0.23 / 1402.08 | 2 | 2 |
3 | 10 | 1059.20 | 5 | 8.44 | 1811 | 76 | 0.31 / 1402.15 | 2 | 2 |
4 | 3 | 1045.84 | 2 | 8.18 | 1783 | 29 | 0.34 / 1402.18 | 2 | 2 |
5 | 3 | 1016.20 | 1 | 8.54 | 1737 | 15 | 0.36 / 1402.20 | 2 | 2 |
6 | 12 | 1101.36 | 5 | 8.07 | 1847 | 75 | 0.43 / 1402.27 | 2 | 2 |
7 | 12 | 2001.84 | 200 | 4.97 | 2751 | 2734 | 3.16 / 1405.01 | 2 | 2 |
8 | 12 | 1999.56 | 125 | 4.73 | 2136 | 1263 | 4.43 / 1406.27 | 2 | 2 |
9 | 7 | 1993.92 | 30 | 4.83 | 2291 | 332 | 4.76 / 1406.60 | 2 | 2 |
10 | 13 | 1934.00 | 38 | 5.97 | 2934 | 666 | 5.42 / 1407.27 | 2 | 2 |
11 | 13 | 1847.92 | 38 | 6.26 | 2827 | 672 | 6.10 / 1407.94 | 2 | 2 |
12 | 13 | 1685.20 | 38 | 6.64 | 2616 | 660 | 6.76 / 1408.60 | 2 | 2 |
13 | 13 | 1528.12 | 38 | 7.00 | 2439 | 649 | 7.41 / 1409.25 | 2 | 2 |
14 | 13 | 1321.68 | 38 | 7.48 | 2132 | 606 | 8.01 / 1409.85 | 2 | 2 |
15 | 13 | 633.12 | 38 | 9.07 | 1231 | 424 | 8.44 / 1410.28 | 2 | 2 |
16 | 13 | 177.16 | 38 | 10.42 | 532 | 211 | 8.65 / 1410.49 | 2 | 2 |
17 | 13 | 14.16 | 38 | 10.89 | 267 | 110 | 8.76 / 1410.60 | 2 | 2 |
18 | 8 | 0.08 | 180 | 10.92 | 257 | 505 | 9.26 / 1411.11 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 33 | 11.35 | 402 | 151 | 0.15 / 1396.92 | 2 | 2 |
2 | 10 | 1030.32 | 6 | 9.05 | 1792 | 97 | 0.25 / 1397.02 | 2 | 2 |
3 | 3 | 1028.16 | 1 | 9.10 | 1769 | 16 | 0.26 / 1397.03 | 2 | 2 |
4 | 12 | 1094.68 | 5 | 7.56 | 1815 | 69 | 0.33 / 1397.10 | 2 | 2 |
5 | 12 | 1147.92 | 200 | 6.71 | 1866 | 2504 | 2.84 / 1399.60 | 2 | 2 |
6 | 12 | 1139.72 | 125 | 5.88 | 1818 | 1336 | 4.17 / 1400.94 | 2 | 2 |
7 | 7 | 1102.32 | 30 | 6.71 | 1800 | 362 | 4.54 / 1401.30 | 2 | 2 |
8 | 8 | -0.32 | 180 | 11.05 | 271 | 539 | 5.07 / 1401.84 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 30 | 12.28 | 397 | 146 | 0.15 / 1391.83 | 2 | 2 |
2 | 10 | 1040.48 | 6 | 10.31 | 1814 | 112 | 0.26 / 1391.94 | 2 | 2 |
3 | 12 | 1067.64 | 5 | 7.20 | 1758 | 63 | 0.32 / 1392.01 | 2 | 2 |
4 | 12 | 1151.80 | 200 | 6.64 | 1874 | 2489 | 2.81 / 1394.50 | 2 | 2 |
5 | 12 | 1148.28 | 125 | 5.85 | 1834 | 1341 | 4.15 / 1395.84 | 2 | 2 |
6 | 7 | 1116.28 | 30 | 6.94 | 1829 | 381 | 4.53 / 1396.22 | 2 | 2 |
7 | 8 | -0.20 | 180 | 11.31 | 270 | 550 | 5.08 / 1396.77 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 13.56 | 395 | 166 | 0.17 / 1386.36 | 2 | 2 |
2 | 3 | 950.88 | -1 | 13.56 | 395 | 0 | 0.00 / 1386.36 | 2 | 2 |
3 | 3 | 1041.12 | 2 | 10.12 | 1803 | 36 | 0.20 / 1386.39 | 2 | 2 |
4 | 12 | 1090.36 | 5 | 7.45 | 1800 | 67 | 0.27 / 1386.46 | 2 | 2 |
5 | 12 | 1169.64 | 200 | 7.07 | 1911 | 2702 | 2.97 / 1389.16 | 2 | 2 |
6 | 12 | 1163.52 | 125 | 6.44 | 1862 | 1499 | 4.47 / 1390.66 | 2 | 2 |
7 | 7 | 1127.88 | 30 | 7.94 | 1863 | 444 | 4.91 / 1391.11 | 2 | 2 |
8 | 8 | -0.40 | 180 | 11.98 | 269 | 580 | 5.49 / 1391.69 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 30 | 13.45 | 395 | 159 | 0.16 / 1377.70 | 2 | 2 |
2 | 3 | 1032.60 | 1 | 9.37 | 1776 | 17 | 0.18 / 1377.71 | 2 | 2 |
3 | 3 | 1012.92 | 1 | 8.54 | 1749 | 15 | 0.19 / 1377.73 | 2 | 2 |
4 | 12 | 1084.52 | 5 | 9.05 | 1850 | 84 | 0.27 / 1377.81 | 2 | 2 |
5 | 12 | 2003.60 | 200 | 5.22 | 2763 | 2885 | 3.16 / 1380.70 | 2 | 2 |
6 | 12 | 1996.12 | 125 | 4.80 | 2276 | 1366 | 4.52 / 1382.06 | 2 | 2 |
7 | 7 | 1985.72 | 30 | 5.77 | 3033 | 525 | 5.05 / 1382.59 | 2 | 2 |
8 | 13 | 1846.20 | 38 | 7.86 | 2876 | 859 | 5.91 / 1383.45 | 2 | 2 |
9 | 13 | 1651.60 | 38 | 8.22 | 2637 | 824 | 6.73 / 1384.27 | 2 | 2 |
10 | 13 | 1225.76 | 38 | 9.21 | 2036 | 713 | 7.45 / 1384.98 | 2 | 2 |
11 | 13 | 495.80 | 38 | 10.88 | 1050 | 434 | 7.88 / 1385.42 | 2 | 2 |
12 | 13 | 15.40 | 38 | 13.13 | 296 | 148 | 8.03 / 1385.57 | 2 | 2 |
13 | 8 | -0.20 | 180 | 12.78 | 272 | 626 | 8.65 / 1386.19 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 31 | 13.33 | 447 | 185 | 0.18 / 1373.02 | 2 | 2 |
2 | 3 | 1031.72 | 1 | 10.26 | 1819 | 19 | 0.20 / 1373.04 | 2 | 2 |
3 | 12 | 1092.04 | 5 | 6.18 | 1753 | 54 | 0.26 / 1373.09 | 2 | 2 |
4 | 12 | 1149.56 | 200 | 5.93 | 1848 | 2192 | 2.45 / 1375.29 | 2 | 2 |
5 | 12 | 1144.60 | 125 | 5.31 | 1802 | 1196 | 3.65 / 1376.48 | 2 | 2 |
6 | 7 | 1112.24 | 30 | 7.48 | 1833 | 411 | 4.06 / 1376.89 | 2 | 2 |
7 | 8 | 0.12 | 180 | 13.13 | 273 | 645 | 4.70 / 1377.54 | 2 | 2 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 31 | 13.67 | 432 | 183 | 0.18 / 1368.03 | 2 | 2 |
2 | 12 | 1099.48 | 5 | 6.63 | 1807 | 60 | 0.24 / 1368.09 | 2 | 2 |
3 | 12 | 1153.40 | 200 | 6.25 | 1864 | 2330 | 2.57 / 1370.42 | 2 | 2 |
4 | 12 | 1149.92 | 125 | 5.60 | 1822 | 1275 | 3.85 / 1371.70 | 2 | 2 |
5 | 7 | 1117.12 | 30 | 7.83 | 1855 | 436 | 4.28 / 1372.13 | 2 | 2 |
6 | 8 | -0.12 | 180 | 13.17 | 297 | 704 | 4.99 / 1372.84 | 2 | 3 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 31 | 13.93 | 441 | 190 | 0.19 / 1362.59 | 2 | 2 |
2 | 12 | 1093.60 | 5 | 7.25 | 1826 | 66 | 0.26 / 1362.66 | 2 | 2 |
3 | 12 | 1155.68 | 200 | 6.92 | 1871 | 2589 | 2.85 / 1365.25 | 2 | 2 |
4 | 12 | 1149.92 | 125 | 6.25 | 1835 | 1434 | 4.28 / 1366.68 | 2 | 2 |
5 | 7 | 1115.32 | 30 | 8.43 | 1857 | 470 | 4.75 / 1367.15 | 2 | 2 |
6 | 8 | -0.24 | 180 | 13.55 | 286 | 698 | 5.45 / 1367.85 | 2 | 2 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 30 | 13.89 | 421 | 175 | 0.18 / 1354.27 | 2 | 2 |
2 | 12 | 1090.56 | 5 | 10.10 | 1891 | 95 | 0.27 / 1354.36 | 2 | 2 |
3 | 12 | 2000.28 | 200 | 5.53 | 2781 | 3076 | 3.35 / 1357.44 | 2 | 2 |
4 | 12 | 1986.76 | 125 | 4.90 | 2344 | 1436 | 4.78 / 1358.87 | 2 | 2 |
5 | 7 | 1968.96 | 30 | 6.89 | 2991 | 618 | 5.40 / 1359.49 | 2 | 2 |
6 | 13 | 1766.24 | 38 | 8.92 | 2783 | 943 | 6.34 / 1360.44 | 2 | 2 |
7 | 13 | 1090.72 | 38 | 10.78 | 1937 | 793 | 7.14 / 1361.23 | 2 | 2 |
8 | 13 | 378.48 | 38 | 12.54 | 913 | 435 | 7.57 / 1361.66 | 2 | 2 |
9 | 8 | -0.20 | 180 | 13.81 | 297 | 738 | 8.31 / 1362.40 | 2 | 3 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 31 | 13.91 | 433 | 187 | 0.19 / 1349.37 | 2 | 2 |
2 | 12 | 1075.04 | 5 | 6.67 | 1762 | 59 | 0.25 / 1349.43 | 2 | 2 |
3 | 12 | 1152.04 | 200 | 5.68 | 1844 | 2095 | 2.34 / 1351.53 | 2 | 2 |
4 | 12 | 1148.76 | 125 | 5.18 | 1793 | 1161 | 3.50 / 1352.69 | 2 | 2 |
5 | 7 | 1119.48 | 30 | 8.22 | 1870 | 461 | 3.96 / 1353.15 | 2 | 2 |
6 | 13 | 79.44 | 38 | 13.66 | 414 | 215 | 4.18 / 1353.36 | 2 | 2 |
7 | 8 | -0.04 | 180 | 13.92 | 290 | 727 | 4.90 / 1354.09 | 2 | 4 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 27 | 14.06 | 415 | 158 | 0.16 / 1344.43 | 2 | 2 |
2 | 3 | 1082.04 | 3 | 10.72 | 1900 | 61 | 0.22 / 1344.49 | 2 | 2 |
3 | 3 | 1012.36 | 1 | 9.96 | 1804 | 18 | 0.24 / 1344.51 | 2 | 2 |
4 | 12 | 1100.88 | 5 | 6.41 | 1800 | 58 | 0.29 / 1344.57 | 2 | 2 |
5 | 12 | 1150.32 | 200 | 5.90 | 1845 | 2177 | 2.47 / 1346.75 | 2 | 2 |
6 | 12 | 1147.36 | 125 | 5.49 | 1812 | 1243 | 3.71 / 1347.99 | 2 | 2 |
7 | 7 | 1115.20 | 30 | 8.58 | 1870 | 481 | 4.20 / 1348.47 | 2 | 2 |
8 | 8 | -0.08 | 180 | 13.91 | 286 | 716 | 4.91 / 1349.19 | 2 | 2 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 33 | 14.07 | 411 | 191 | 0.19 / 1339.34 | 2 | 2 |
2 | 3 | 862.88 | -2 | 14.07 | 411 | 0 | 0.00 / 1339.34 | 2 | 2 |
3 | 3 | 1025.88 | 1 | 10.51 | 1807 | 19 | 0.21 / 1339.35 | 2 | 2 |
4 | 12 | 1111.44 | 5 | 6.71 | 1819 | 61 | 0.27 / 1339.42 | 2 | 2 |
5 | 12 | 1157.52 | 200 | 6.12 | 1865 | 2283 | 2.55 / 1341.70 | 2 | 2 |
6 | 12 | 1154.64 | 125 | 5.90 | 1827 | 1347 | 3.90 / 1343.05 | 2 | 2 |
7 | 7 | 1122.16 | 30 | 8.87 | 1898 | 505 | 4.41 / 1343.55 | 2 | 2 |
8 | 8 | -0.16 | 180 | 13.97 | 288 | 724 | 5.13 / 1344.27 | 2 | 2 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 29 | 13.98 | 410 | 166 | 0.17 / 1331.04 | 2 | 2 |
2 | 12 | 1092.28 | 5 | 10.25 | 1898 | 97 | 0.26 / 1331.14 | 2 | 2 |
3 | 12 | 1988.04 | 200 | 5.35 | 2691 | 2879 | 3.14 / 1334.02 | 2 | 2 |
4 | 12 | 1975.16 | 125 | 4.98 | 2371 | 1476 | 4.62 / 1335.50 | 2 | 2 |
5 | 7 | 1958.56 | 30 | 7.58 | 2993 | 681 | 5.30 / 1336.18 | 2 | 2 |
6 | 13 | 1759.24 | 38 | 9.63 | 2786 | 1020 | 6.32 / 1337.20 | 2 | 2 |
7 | 13 | 1080.32 | 38 | 11.37 | 1898 | 820 | 7.14 / 1338.02 | 2 | 2 |
8 | 13 | 326.64 | 38 | 13.08 | 812 | 404 | 7.54 / 1338.42 | 2 | 2 |
9 | 8 | 0.16 | 180 | 14.10 | 286 | 726 | 8.27 / 1339.14 | 2 | 3 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 31 | 13.99 | 428 | 186 | 0.19 / 1326.15 | 2 | 2 |
2 | 12 | 1075.76 | 5 | 5.90 | 1725 | 51 | 0.24 / 1326.20 | 2 | 2 |
3 | 12 | 1157.84 | 200 | 5.47 | 1838 | 2011 | 2.25 / 1328.21 | 2 | 2 |
4 | 12 | 1158.96 | 125 | 5.49 | 1826 | 1253 | 3.50 / 1329.47 | 2 | 2 |
5 | 7 | 1130.96 | 30 | 8.76 | 1895 | 498 | 4.00 / 1329.96 | 2 | 2 |
6 | 13 | 57.24 | 38 | 13.87 | 369 | 194 | 4.19 / 1330.16 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.08 | 283 | 717 | 4.91 / 1330.88 | 2 | 3 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 14.03 | 407 | 160 | 0.16 / 1321.05 | 2 | 2 |
2 | 10 | 1031.88 | 5 | 10.58 | 1815 | 96 | 0.26 / 1321.15 | 2 | 2 |
3 | 3 | 1016.68 | 1 | 9.81 | 1785 | 18 | 0.27 / 1321.16 | 2 | 2 |
4 | 12 | 1100.36 | 5 | 4.85 | 2075 | 50 | 0.32 / 1321.22 | 2 | 2 |
5 | 12 | 1152.24 | 200 | 5.73 | 1844 | 2113 | 2.44 / 1323.33 | 2 | 2 |
6 | 12 | 1152.12 | 125 | 6.13 | 1841 | 1411 | 3.85 / 1324.74 | 2 | 2 |
7 | 7 | 1121.12 | 30 | 8.99 | 1881 | 507 | 4.35 / 1325.25 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.03 | 285 | 720 | 5.07 / 1325.97 | 2 | 2 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 31 | 14.15 | 404 | 177 | 0.18 / 1315.68 | 2 | 2 |
2 | 3 | 953.72 | -1 | 14.15 | 404 | 0 | 0.00 / 1315.68 | 2 | 2 |
3 | 12 | 1057.20 | 5 | 6.04 | 1684 | 51 | 0.23 / 1315.73 | 2 | 2 |
4 | 12 | 1137.36 | 200 | 6.46 | 1829 | 2363 | 2.59 / 1318.10 | 2 | 2 |
5 | 12 | 1118.16 | 125 | 6.88 | 1804 | 1551 | 4.14 / 1319.65 | 2 | 2 |
6 | 7 | 1076.76 | 30 | 9.35 | 1841 | 516 | 4.66 / 1320.16 | 2 | 2 |
7 | 8 | -0.40 | 180 | 14.00 | 289 | 728 | 5.39 / 1320.89 | 2 | 5 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 14.10 | 402 | 164 | 0.16 / 1307.36 | 2 | 2 |
2 | 12 | 1083.04 | 5 | 10.11 | 1882 | 95 | 0.26 / 1307.46 | 2 | 2 |
3 | 12 | 1994.76 | 200 | 5.37 | 2758 | 2962 | 3.22 / 1310.42 | 2 | 2 |
4 | 12 | 1981.68 | 125 | 5.10 | 2565 | 1635 | 4.86 / 1312.06 | 2 | 2 |
5 | 7 | 1963.88 | 30 | 8.26 | 3046 | 755 | 5.61 / 1312.81 | 2 | 2 |
6 | 13 | 1554.08 | 38 | 10.82 | 2550 | 1048 | 6.66 / 1313.86 | 2 | 2 |
7 | 13 | 821.68 | 38 | 12.20 | 1547 | 717 | 7.38 / 1314.58 | 2 | 2 |
8 | 13 | 81.04 | 38 | 13.97 | 403 | 214 | 7.59 / 1314.79 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.25 | 278 | 713 | 8.30 / 1315.50 | 2 | 3 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 31 | 14.01 | 442 | 192 | 0.19 / 1302.51 | 2 | 2 |
2 | 12 | 1070.44 | 5 | 4.81 | 1871 | 45 | 0.24 / 1302.56 | 2 | 2 |
3 | 12 | 1159.84 | 200 | 5.54 | 1842 | 2041 | 2.28 / 1304.60 | 2 | 2 |
4 | 12 | 1161.48 | 125 | 5.92 | 1844 | 1365 | 3.64 / 1305.96 | 2 | 2 |
5 | 7 | 1131.52 | 30 | 9.16 | 1893 | 520 | 4.16 / 1306.48 | 2 | 2 |
6 | 8 | -0.04 | 180 | 14.14 | 281 | 715 | 4.88 / 1307.20 | 2 | 2 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 31 | 14.01 | 441 | 192 | 0.19 / 1297.46 | 2 | 2 |
2 | 12 | 1103.92 | 5 | 4.81 | 1855 | 45 | 0.24 / 1297.51 | 2 | 2 |
3 | 12 | 1150.56 | 200 | 5.76 | 1847 | 2128 | 2.36 / 1299.63 | 2 | 2 |
4 | 12 | 1150.52 | 125 | 6.14 | 1838 | 1411 | 3.77 / 1301.04 | 2 | 2 |
5 | 7 | 1118.96 | 30 | 9.12 | 1908 | 522 | 4.30 / 1301.57 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.10 | 298 | 756 | 5.05 / 1302.32 | 2 | 3 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 30 | 14.14 | 425 | 180 | 0.18 / 1292.10 | 2 | 2 |
2 | 12 | 1091.40 | 5 | 4.83 | 1980 | 48 | 0.23 / 1292.15 | 2 | 2 |
3 | 12 | 1160.72 | 200 | 6.20 | 1862 | 2309 | 2.54 / 1294.46 | 2 | 2 |
4 | 12 | 1158.60 | 125 | 6.61 | 1851 | 1529 | 4.07 / 1295.99 | 2 | 2 |
5 | 7 | 1124.44 | 30 | 9.49 | 1896 | 540 | 4.61 / 1296.53 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.12 | 291 | 740 | 5.35 / 1297.27 | 2 | 3 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 31 | 14.04 | 410 | 178 | 0.18 / 1283.55 | 2 | 2 |
2 | 3 | 945.84 | -1 | 14.04 | 410 | 0 | 0.00 / 1283.55 | 2 | 2 |
3 | 3 | 1046.08 | 2 | 10.21 | 1839 | 38 | 0.22 / 1283.59 | 2 | 2 |
4 | 12 | 1086.80 | 5 | 10.11 | 1888 | 95 | 0.31 / 1283.68 | 2 | 2 |
5 | 12 | 2001.96 | 200 | 5.30 | 2710 | 2873 | 3.18 / 1286.55 | 2 | 2 |
6 | 12 | 1990.60 | 125 | 5.10 | 2602 | 1659 | 4.84 / 1288.21 | 2 | 2 |
7 | 7 | 1974.68 | 30 | 8.77 | 3072 | 808 | 5.65 / 1289.02 | 2 | 2 |
8 | 13 | 1758.76 | 38 | 10.72 | 2839 | 1156 | 6.81 / 1290.18 | 2 | 2 |
9 | 13 | 839.52 | 38 | 12.28 | 1582 | 738 | 7.55 / 1290.92 | 2 | 2 |
10 | 13 | 162.12 | 38 | 13.80 | 536 | 281 | 7.83 / 1291.20 | 2 | 2 |
11 | 8 | -0.08 | 180 | 14.25 | 283 | 726 | 8.55 / 1291.92 | 2 | 2 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 31 | 14.00 | 430 | 187 | 0.19 / 1278.36 | 2 | 2 |
2 | 12 | 1083.84 | 5 | 4.76 | 1666 | 40 | 0.23 / 1278.40 | 2 | 2 |
3 | 12 | 1147.84 | 200 | 4.93 | 1788 | 1763 | 1.99 / 1280.17 | 2 | 2 |
4 | 12 | 1159.24 | 125 | 5.50 | 1845 | 1268 | 3.26 / 1281.43 | 2 | 2 |
5 | 7 | 1147.24 | 30 | 9.30 | 1938 | 541 | 3.80 / 1281.98 | 2 | 2 |
6 | 13 | 458.32 | 38 | 12.71 | 1024 | 495 | 4.29 / 1282.47 | 2 | 2 |
7 | 13 | 38.00 | 38 | 14.02 | 339 | 181 | 4.47 / 1282.65 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.19 | 282 | 720 | 5.19 / 1283.37 | 2 | 4 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 30 | 14.16 | 418 | 178 | 0.18 / 1273.42 | 2 | 2 |
2 | 12 | 1078.52 | 5 | 4.74 | 1588 | 38 | 0.22 / 1273.46 | 2 | 2 |
3 | 12 | 1161.88 | 200 | 5.10 | 1826 | 1863 | 2.08 / 1275.32 | 2 | 2 |
4 | 12 | 1169.00 | 125 | 5.98 | 1864 | 1393 | 3.47 / 1276.71 | 2 | 2 |
5 | 7 | 1144.00 | 30 | 9.33 | 1926 | 539 | 4.01 / 1277.25 | 2 | 2 |
6 | 13 | 63.60 | 38 | 13.92 | 378 | 200 | 4.21 / 1277.45 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.16 | 284 | 724 | 4.93 / 1278.18 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 14.15 | 391 | 166 | 0.17 / 1268.37 | 2 | 2 |
2 | 12 | 1052.92 | 5 | 4.73 | 1573 | 37 | 0.20 / 1268.40 | 2 | 2 |
3 | 12 | 1152.40 | 200 | 5.45 | 1841 | 2007 | 2.21 / 1270.41 | 2 | 2 |
4 | 12 | 1156.84 | 125 | 6.65 | 1861 | 1547 | 3.76 / 1271.96 | 2 | 2 |
5 | 7 | 1127.32 | 30 | 9.71 | 1910 | 556 | 4.31 / 1272.51 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.18 | 286 | 730 | 5.04 / 1273.24 | 2 | 2 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 31 | 14.22 | 414 | 182 | 0.18 / 1259.58 | 2 | 2 |
2 | 12 | 1064.84 | 5 | 9.60 | 1853 | 89 | 0.27 / 1259.67 | 2 | 2 |
3 | 12 | 2001.40 | 200 | 5.06 | 2706 | 2738 | 3.01 / 1262.41 | 2 | 2 |
4 | 12 | 1993.44 | 125 | 5.28 | 2802 | 1849 | 4.86 / 1264.26 | 2 | 2 |
5 | 7 | 1981.16 | 30 | 9.23 | 3089 | 855 | 5.71 / 1265.11 | 2 | 2 |
6 | 13 | 1783.24 | 38 | 10.99 | 2863 | 1196 | 6.91 / 1266.31 | 2 | 2 |
7 | 13 | 1059.32 | 38 | 12.25 | 1899 | 884 | 7.79 / 1267.19 | 2 | 2 |
8 | 13 | 150.28 | 38 | 13.96 | 517 | 274 | 8.07 / 1267.47 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.32 | 284 | 732 | 8.80 / 1268.20 | 2 | 2 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 31 | 14.15 | 430 | 189 | 0.19 / 1254.24 | 2 | 2 |
2 | 12 | 1068.76 | 5 | 4.71 | 1438 | 34 | 0.22 / 1254.28 | 2 | 2 |
3 | 12 | 1169.32 | 200 | 4.81 | 1811 | 1742 | 1.96 / 1256.02 | 2 | 2 |
4 | 12 | 1188.12 | 125 | 5.95 | 1880 | 1398 | 3.36 / 1257.42 | 2 | 2 |
5 | 7 | 1180.72 | 30 | 9.37 | 1990 | 559 | 3.92 / 1257.98 | 2 | 2 |
6 | 13 | 459.72 | 38 | 12.96 | 1027 | 506 | 4.43 / 1258.48 | 2 | 2 |
7 | 13 | 39.00 | 38 | 14.11 | 342 | 183 | 4.61 / 1258.67 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.25 | 286 | 734 | 5.35 / 1259.40 | 2 | 6 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 30 | 14.13 | 448 | 190 | 0.19 / 1249.06 | 2 | 2 |
2 | 12 | 1090.40 | 5 | 4.73 | 1539 | 36 | 0.23 / 1249.10 | 2 | 2 |
3 | 12 | 1155.88 | 200 | 5.40 | 1829 | 1975 | 2.20 / 1251.07 | 2 | 2 |
4 | 12 | 1157.12 | 125 | 6.54 | 1855 | 1516 | 3.72 / 1252.59 | 2 | 2 |
5 | 7 | 1126.36 | 30 | 9.54 | 1907 | 546 | 4.26 / 1253.13 | 2 | 2 |
6 | 13 | 24.40 | 38 | 14.10 | 326 | 175 | 4.44 / 1253.31 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.22 | 291 | 745 | 5.18 / 1254.05 | 2 | 3 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 30 | 14.27 | 432 | 185 | 0.18 / 1243.41 | 2 | 2 |
2 | 12 | 1090.60 | 5 | 4.76 | 1681 | 40 | 0.22 / 1243.45 | 2 | 2 |
3 | 12 | 1150.20 | 200 | 6.42 | 1846 | 2370 | 2.60 / 1245.82 | 2 | 2 |
4 | 12 | 1146.12 | 125 | 7.36 | 1857 | 1708 | 4.30 / 1247.53 | 2 | 2 |
5 | 7 | 1109.12 | 30 | 9.95 | 1877 | 560 | 4.86 / 1248.09 | 2 | 2 |
6 | 8 | -0.40 | 180 | 14.17 | 306 | 780 | 5.64 / 1248.87 | 2 | 3 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 29 | 14.12 | 445 | 182 | 0.18 / 1234.79 | 2 | 2 |
2 | 3 | 1021.24 | 1 | 10.39 | 1795 | 19 | 0.20 / 1234.81 | 2 | 2 |
3 | 3 | 1020.60 | 1 | 10.03 | 1788 | 18 | 0.22 / 1234.83 | 2 | 2 |
4 | 12 | 1104.04 | 5 | 10.28 | 1935 | 99 | 0.32 / 1234.93 | 2 | 2 |
5 | 12 | 1986.16 | 200 | 5.32 | 2826 | 3007 | 3.33 / 1237.94 | 2 | 2 |
6 | 12 | 1975.88 | 125 | 5.47 | 2962 | 2025 | 5.35 / 1239.96 | 2 | 2 |
7 | 7 | 1959.76 | 30 | 9.59 | 3058 | 880 | 6.23 / 1240.84 | 2 | 2 |
8 | 13 | 1305.52 | 38 | 12.12 | 2213 | 1019 | 7.25 / 1241.86 | 2 | 2 |
9 | 13 | 574.84 | 38 | 13.21 | 1214 | 609 | 7.86 / 1242.47 | 2 | 2 |
10 | 8 | -0.20 | 180 | 14.33 | 293 | 756 | 8.61 / 1243.23 | 2 | 2 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 29 | 14.21 | 417 | 172 | 0.17 / 1229.66 | 2 | 2 |
2 | 3 | 1047.28 | 2 | 10.45 | 1839 | 38 | 0.21 / 1229.69 | 2 | 2 |
3 | 12 | 1097.68 | 5 | 4.71 | 1461 | 34 | 0.24 / 1229.73 | 2 | 2 |
4 | 12 | 1159.48 | 200 | 5.37 | 1834 | 1970 | 2.21 / 1231.70 | 2 | 2 |
5 | 12 | 1165.52 | 125 | 6.72 | 1874 | 1574 | 3.79 / 1233.27 | 2 | 2 |
6 | 7 | 1137.36 | 30 | 9.72 | 1936 | 565 | 4.35 / 1233.84 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.21 | 303 | 775 | 5.13 / 1234.61 | 2 | 3 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 30 | 14.17 | 395 | 168 | 0.17 / 1224.30 | 2 | 2 |
2 | 12 | 1063.36 | 5 | 4.73 | 1525 | 36 | 0.20 / 1224.34 | 2 | 2 |
3 | 12 | 1154.56 | 200 | 5.95 | 1830 | 2178 | 2.38 / 1226.52 | 2 | 2 |
4 | 12 | 1156.72 | 125 | 7.22 | 1853 | 1672 | 4.05 / 1228.19 | 2 | 2 |
5 | 7 | 1124.24 | 30 | 9.80 | 1898 | 558 | 4.61 / 1228.75 | 2 | 2 |
6 | 8 | -0.12 | 180 | 14.20 | 288 | 736 | 5.35 / 1229.48 | 2 | 2 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 30 | 14.26 | 439 | 188 | 0.19 / 1218.27 | 2 | 2 |
2 | 12 | 1083.28 | 5 | 4.93 | 1740 | 43 | 0.23 / 1218.31 | 2 | 2 |
3 | 12 | 1160.80 | 200 | 7.07 | 1863 | 2634 | 2.86 / 1220.95 | 2 | 2 |
4 | 12 | 1156.48 | 125 | 7.97 | 1860 | 1853 | 4.72 / 1222.80 | 2 | 2 |
5 | 7 | 1118.88 | 30 | 10.18 | 1906 | 582 | 5.30 / 1223.38 | 2 | 2 |
6 | 8 | -0.60 | 180 | 14.20 | 295 | 754 | 6.05 / 1224.14 | 2 | 4 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 29 | 14.26 | 407 | 168 | 0.17 / 1209.86 | 2 | 2 |
2 | 12 | 1092.92 | 5 | 10.07 | 1895 | 95 | 0.26 / 1209.96 | 2 | 2 |
3 | 12 | 1987.48 | 200 | 5.40 | 2946 | 3182 | 3.45 / 1213.14 | 2 | 2 |
4 | 12 | 1974.00 | 125 | 6.43 | 2995 | 2407 | 5.85 / 1215.54 | 2 | 2 |
5 | 7 | 1949.44 | 30 | 9.88 | 3045 | 903 | 6.76 / 1216.45 | 2 | 2 |
6 | 13 | 689.52 | 38 | 13.12 | 1372 | 684 | 7.44 / 1217.13 | 2 | 2 |
7 | 13 | 45.84 | 38 | 14.21 | 360 | 194 | 7.63 / 1217.33 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.38 | 292 | 756 | 8.39 / 1218.08 | 2 | 3 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 30 | 14.20 | 420 | 179 | 0.18 / 1204.57 | 2 | 2 |
2 | 3 | 955.40 | -1 | 14.20 | 420 | 0 | 0.00 / 1204.57 | 2 | 2 |
3 | 3 | 1048.28 | 2 | 10.71 | 1838 | 39 | 0.22 / 1204.61 | 2 | 2 |
4 | 12 | 1110.20 | 5 | 4.72 | 1524 | 36 | 0.25 / 1204.64 | 2 | 2 |
5 | 12 | 1150.32 | 200 | 5.78 | 1830 | 2115 | 2.37 / 1206.76 | 2 | 2 |
6 | 12 | 1150.08 | 125 | 6.98 | 1845 | 1610 | 3.98 / 1208.37 | 2 | 2 |
7 | 7 | 1115.84 | 30 | 10.01 | 1884 | 566 | 4.55 / 1208.94 | 2 | 2 |
8 | 8 | -0.32 | 180 | 14.25 | 295 | 757 | 5.30 / 1209.69 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 28 | 14.19 | 425 | 169 | 0.17 / 1199.40 | 2 | 2 |
2 | 3 | 1036.48 | 1 | 10.72 | 1830 | 20 | 0.19 / 1199.42 | 2 | 2 |
3 | 3 | 1016.48 | 1 | 10.14 | 1783 | 18 | 0.21 / 1199.44 | 2 | 2 |
4 | 12 | 1085.96 | 5 | 4.72 | 1503 | 35 | 0.24 / 1199.48 | 2 | 2 |
5 | 12 | 1164.36 | 200 | 5.33 | 1842 | 1964 | 2.21 / 1201.44 | 2 | 2 |
6 | 12 | 1171.48 | 125 | 6.94 | 1872 | 1624 | 3.83 / 1203.06 | 2 | 2 |
7 | 7 | 1144.24 | 30 | 10.00 | 1914 | 574 | 4.40 / 1203.64 | 2 | 2 |
8 | 8 | -0.16 | 180 | 14.27 | 293 | 753 | 5.16 / 1204.39 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 30 | 14.23 | 424 | 181 | 0.18 / 1195.23 | 2 | 2 |
2 | 3 | 936.72 | -1 | 14.23 | 424 | 0 | 0.00 / 1195.23 | 2 | 2 |
3 | 3 | 1031.68 | 1 | 10.51 | 1822 | 19 | 0.20 / 1195.25 | 2 | 2 |
4 | 12 | 1109.32 | 6 | 4.76 | 1691 | 48 | 0.25 / 1195.29 | 2 | 2 |
5 | 12 | 1155.56 | 130 | 6.03 | 1855 | 1454 | 1.70 / 1196.75 | 2 | 2 |
6 | 12 | 1162.04 | 65 | 7.19 | 1881 | 879 | 2.58 / 1197.63 | 2 | 2 |
7 | 7 | 1148.24 | 30 | 9.51 | 1930 | 551 | 3.13 / 1198.18 | 2 | 2 |
8 | 13 | 180.88 | 38 | 13.84 | 584 | 307 | 3.44 / 1198.48 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.30 | 291 | 749 | 4.19 / 1199.23 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 14.16 | 405 | 166 | 0.17 / 1188.04 | 2 | 2 |
2 | 12 | 1076.44 | 6 | 9.43 | 1839 | 104 | 0.27 / 1188.14 | 2 | 2 |
3 | 12 | 1977.92 | 130 | 5.20 | 2812 | 1901 | 2.17 / 1190.04 | 2 | 2 |
4 | 12 | 1972.80 | 65 | 6.03 | 2964 | 1162 | 3.33 / 1191.20 | 2 | 2 |
5 | 7 | 1963.24 | 30 | 9.45 | 3101 | 879 | 4.21 / 1192.08 | 2 | 2 |
6 | 13 | 1748.92 | 38 | 11.48 | 2824 | 1232 | 5.44 / 1193.31 | 2 | 2 |
7 | 13 | 801.16 | 38 | 12.93 | 1561 | 767 | 6.21 / 1194.08 | 2 | 2 |
8 | 13 | 67.68 | 38 | 14.17 | 394 | 212 | 6.42 / 1194.29 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.38 | 291 | 753 | 7.18 / 1195.05 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 30 | 14.12 | 409 | 173 | 0.17 / 1183.59 | 2 | 2 |
2 | 12 | 1052.64 | 6 | 4.69 | 1406 | 40 | 0.21 / 1183.63 | 2 | 2 |
3 | 12 | 1148.40 | 130 | 4.85 | 1774 | 1119 | 1.33 / 1184.74 | 2 | 2 |
4 | 12 | 1160.88 | 65 | 6.24 | 1853 | 752 | 2.08 / 1185.50 | 2 | 2 |
5 | 7 | 1160.48 | 30 | 9.11 | 1937 | 529 | 2.61 / 1186.03 | 2 | 2 |
6 | 13 | 954.88 | 38 | 11.71 | 1733 | 771 | 3.38 / 1186.80 | 2 | 2 |
7 | 13 | 202.56 | 38 | 13.75 | 633 | 331 | 3.71 / 1187.13 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.30 | 288 | 741 | 4.46 / 1187.87 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 30 | 14.18 | 427 | 182 | 0.18 / 1179.40 | 2 | 2 |
2 | 12 | 1089.60 | 6 | 4.73 | 1554 | 44 | 0.23 / 1179.44 | 2 | 2 |
3 | 12 | 1155.84 | 130 | 5.54 | 1841 | 1326 | 1.55 / 1180.77 | 2 | 2 |
4 | 12 | 1162.96 | 65 | 6.77 | 1881 | 828 | 2.38 / 1181.59 | 2 | 2 |
5 | 7 | 1150.44 | 30 | 9.34 | 1926 | 540 | 2.92 / 1182.13 | 2 | 2 |
6 | 13 | 389.80 | 38 | 13.26 | 952 | 480 | 3.40 / 1182.61 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.25 | 312 | 800 | 4.20 / 1183.41 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 30 | 14.25 | 426 | 182 | 0.18 / 1175.10 | 2 | 2 |
2 | 12 | 1104.16 | 6 | 4.78 | 1773 | 51 | 0.23 / 1175.15 | 2 | 2 |
3 | 12 | 1154.16 | 130 | 6.57 | 1843 | 1574 | 1.81 / 1176.73 | 2 | 2 |
4 | 12 | 1158.36 | 65 | 7.59 | 1868 | 922 | 2.73 / 1177.65 | 2 | 2 |
5 | 7 | 1141.56 | 30 | 9.72 | 1905 | 555 | 3.28 / 1178.20 | 2 | 2 |
6 | 13 | 133.28 | 38 | 13.92 | 506 | 268 | 3.55 / 1178.47 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.28 | 289 | 743 | 4.29 / 1179.21 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 29 | 14.16 | 421 | 173 | 0.17 / 1168.40 | 2 | 2 |
2 | 12 | 1075.56 | 6 | 10.44 | 1875 | 117 | 0.29 / 1168.51 | 2 | 2 |
3 | 12 | 1963.96 | 130 | 5.79 | 2980 | 2243 | 2.53 / 1170.76 | 2 | 2 |
4 | 12 | 1956.64 | 65 | 7.11 | 3001 | 1387 | 3.92 / 1172.14 | 2 | 2 |
5 | 7 | 1943.28 | 30 | 9.86 | 3057 | 904 | 4.82 / 1173.05 | 2 | 2 |
6 | 13 | 1001.76 | 38 | 12.75 | 1813 | 878 | 5.70 / 1173.93 | 2 | 2 |
7 | 13 | 136.20 | 38 | 14.05 | 494 | 264 | 5.97 / 1174.19 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.38 | 282 | 730 | 6.70 / 1174.92 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 30 | 14.15 | 451 | 191 | 0.19 / 1164.15 | 2 | 2 |
2 | 12 | 1088.24 | 6 | 4.70 | 1453 | 41 | 0.23 / 1164.19 | 2 | 2 |
3 | 12 | 1158.84 | 130 | 5.09 | 1819 | 1204 | 1.44 / 1165.40 | 2 | 2 |
4 | 12 | 1169.12 | 65 | 6.54 | 1890 | 803 | 2.24 / 1166.20 | 2 | 2 |
5 | 7 | 1161.64 | 30 | 9.49 | 1937 | 551 | 2.79 / 1166.75 | 2 | 2 |
6 | 13 | 491.04 | 38 | 13.15 | 1083 | 541 | 3.33 / 1167.29 | 2 | 2 |
7 | 13 | 19.44 | 38 | 14.20 | 319 | 172 | 3.50 / 1167.46 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.30 | 295 | 759 | 4.26 / 1168.22 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 32 | 14.20 | 413 | 188 | 0.19 / 1160.07 | 2 | 2 |
2 | 3 | 954.16 | -1 | 14.20 | 413 | 0 | 0.00 / 1160.07 | 2 | 2 |
3 | 3 | 1043.32 | 2 | 9.81 | 1817 | 36 | 0.22 / 1160.10 | 2 | 2 |
4 | 12 | 1118.12 | 6 | 4.71 | 1471 | 42 | 0.26 / 1160.15 | 2 | 2 |
5 | 12 | 1155.08 | 130 | 5.49 | 1829 | 1305 | 1.57 / 1161.45 | 2 | 2 |
6 | 12 | 1163.88 | 50 | 7.09 | 1899 | 673 | 2.24 / 1162.12 | 2 | 2 |
7 | 7 | 1154.52 | 30 | 9.44 | 1928 | 546 | 2.79 / 1162.67 | 2 | 2 |
8 | 13 | 456.44 | 38 | 13.19 | 1027 | 515 | 3.30 / 1163.19 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.28 | 301 | 774 | 4.08 / 1163.96 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 27 | 14.20 | 439 | 168 | 0.17 / 1155.93 | 2 | 2 |
2 | 10 | 1018.88 | 4 | 11.78 | 1822 | 86 | 0.25 / 1156.01 | 2 | 2 |
3 | 12 | 1100.36 | 6 | 4.77 | 1727 | 49 | 0.30 / 1156.06 | 2 | 2 |
4 | 12 | 1157.04 | 130 | 6.49 | 1856 | 1566 | 1.87 / 1157.63 | 2 | 2 |
5 | 12 | 1162.20 | 50 | 7.94 | 1895 | 752 | 2.62 / 1158.38 | 2 | 2 |
6 | 7 | 1149.04 | 30 | 9.73 | 1922 | 561 | 3.18 / 1158.94 | 2 | 2 |
7 | 13 | 82.32 | 38 | 14.07 | 405 | 217 | 3.40 / 1159.16 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.31 | 281 | 724 | 4.12 / 1159.88 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 32 | 14.19 | 425 | 193 | 0.19 / 1149.49 | 2 | 2 |
2 | 3 | 932.72 | -1 | 14.19 | 425 | 0 | 0.00 / 1149.49 | 2 | 2 |
3 | 3 | 1022.84 | 1 | 9.82 | 1801 | 18 | 0.21 / 1149.51 | 2 | 2 |
4 | 12 | 1090.04 | 6 | 10.40 | 1900 | 119 | 0.33 / 1149.62 | 2 | 2 |
5 | 12 | 1956.12 | 130 | 6.29 | 2967 | 2426 | 2.76 / 1152.05 | 2 | 2 |
6 | 12 | 1947.04 | 50 | 7.86 | 3002 | 1180 | 3.94 / 1153.23 | 2 | 2 |
7 | 7 | 1931.88 | 30 | 10.01 | 3030 | 910 | 4.85 / 1154.14 | 2 | 2 |
8 | 13 | 622.52 | 38 | 13.25 | 1297 | 653 | 5.50 / 1154.79 | 2 | 2 |
9 | 13 | 30.08 | 38 | 14.22 | 346 | 187 | 5.69 / 1154.98 | 2 | 2 |
10 | 8 | -0.16 | 180 | 14.36 | 301 | 778 | 6.46 / 1155.76 | 2 | 4 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 29 | 14.16 | 431 | 177 | 0.18 / 1145.20 | 2 | 2 |
2 | 3 | 1012.44 | 1 | 9.92 | 1755 | 17 | 0.19 / 1145.22 | 2 | 2 |
3 | 12 | 1078.80 | 6 | 4.70 | 1421 | 40 | 0.23 / 1145.26 | 2 | 2 |
4 | 12 | 1167.80 | 130 | 5.06 | 1838 | 1209 | 1.44 / 1146.47 | 2 | 2 |
5 | 12 | 1178.00 | 50 | 6.85 | 1907 | 653 | 2.10 / 1147.12 | 2 | 2 |
6 | 7 | 1172.12 | 30 | 9.56 | 1956 | 561 | 2.66 / 1147.69 | 2 | 2 |
7 | 13 | 716.48 | 38 | 12.70 | 1429 | 690 | 3.35 / 1148.37 | 2 | 2 |
8 | 13 | 41.80 | 38 | 14.17 | 344 | 185 | 3.53 / 1148.56 | 2 | 2 |
9 | 8 | -0.04 | 180 | 14.33 | 285 | 735 | 4.27 / 1149.30 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 33 | 14.12 | 405 | 189 | 0.19 / 1140.85 | 2 | 2 |
2 | 3 | 861.24 | -2 | 14.12 | 405 | 0 | 0.00 / 1140.85 | 2 | 2 |
3 | 3 | 1038.80 | 2 | 8.84 | 1764 | 31 | 0.22 / 1140.88 | 2 | 2 |
4 | 12 | 1096.96 | 6 | 4.68 | 1351 | 38 | 0.26 / 1140.92 | 2 | 2 |
5 | 12 | 1157.76 | 130 | 5.16 | 1829 | 1227 | 1.48 / 1142.15 | 2 | 2 |
6 | 12 | 1169.68 | 50 | 7.08 | 1907 | 675 | 2.16 / 1142.82 | 2 | 2 |
7 | 7 | 1165.28 | 30 | 9.53 | 1947 | 557 | 2.72 / 1143.38 | 2 | 2 |
8 | 13 | 712.96 | 38 | 12.66 | 1421 | 684 | 3.40 / 1144.06 | 2 | 2 |
9 | 13 | 39.08 | 38 | 14.13 | 358 | 192 | 3.59 / 1144.25 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.29 | 301 | 774 | 4.37 / 1145.03 | 2 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 28 | 14.23 | 432 | 172 | 0.17 / 1136.67 | 2 | 2 |
2 | 10 | 1004.52 | 5 | 11.82 | 1802 | 106 | 0.28 / 1136.78 | 2 | 2 |
3 | 12 | 1051.44 | 7 | 4.77 | 1736 | 58 | 0.34 / 1136.84 | 2 | 2 |
4 | 12 | 1147.96 | 130 | 6.54 | 1856 | 1578 | 1.91 / 1138.42 | 2 | 2 |
5 | 12 | 1154.28 | 40 | 8.20 | 1899 | 623 | 2.54 / 1139.04 | 2 | 2 |
6 | 7 | 1143.00 | 30 | 9.81 | 1928 | 567 | 3.10 / 1139.61 | 2 | 2 |
7 | 13 | 177.88 | 38 | 13.86 | 574 | 302 | 3.41 / 1139.91 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.28 | 293 | 753 | 4.16 / 1140.66 | 2 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 28 | 14.17 | 435 | 173 | 0.17 / 1130.48 | 2 | 2 |
2 | 3 | 1083.20 | 3 | 11.02 | 1880 | 62 | 0.23 / 1130.54 | 2 | 2 |
3 | 3 | 1019.00 | 1 | 10.31 | 1788 | 18 | 0.25 / 1130.56 | 2 | 2 |
4 | 12 | 1075.36 | 7 | 10.73 | 1882 | 141 | 0.39 / 1130.70 | 2 | 2 |
5 | 12 | 1941.56 | 130 | 6.50 | 2960 | 2501 | 2.90 / 1133.20 | 2 | 2 |
6 | 12 | 1932.36 | 40 | 8.33 | 3001 | 1000 | 3.90 / 1134.20 | 2 | 2 |
7 | 7 | 1918.72 | 30 | 10.08 | 3020 | 913 | 4.81 / 1135.12 | 2 | 2 |
8 | 13 | 564.04 | 38 | 13.34 | 1203 | 610 | 5.42 / 1135.73 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.36 | 300 | 775 | 6.19 / 1136.50 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 29 | 14.20 | 411 | 169 | 0.17 / 1126.17 | 2 | 2 |
2 | 3 | 1013.44 | 1 | 9.02 | 1765 | 16 | 0.19 / 1126.18 | 2 | 2 |
3 | 12 | 1081.60 | 7 | 4.69 | 1417 | 47 | 0.23 / 1126.23 | 2 | 2 |
4 | 12 | 1162.24 | 130 | 5.08 | 1831 | 1209 | 1.44 / 1127.44 | 2 | 2 |
5 | 12 | 1172.04 | 40 | 7.24 | 1913 | 554 | 1.99 / 1127.99 | 2 | 2 |
6 | 7 | 1166.84 | 30 | 9.61 | 1957 | 564 | 2.56 / 1128.56 | 2 | 2 |
7 | 13 | 944.32 | 38 | 12.19 | 1720 | 797 | 3.36 / 1129.36 | 2 | 2 |
8 | 13 | 70.08 | 38 | 14.11 | 390 | 209 | 3.56 / 1129.56 | 2 | 2 |
9 | 8 | 0.12 | 180 | 14.32 | 288 | 742 | 4.31 / 1130.31 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 31 | 14.17 | 424 | 186 | 0.19 / 1122.17 | 2 | 2 |
2 | 3 | 925.56 | -1 | 14.17 | 424 | 0 | 0.00 / 1122.17 | 2 | 2 |
3 | 3 | 1017.08 | 1 | 9.79 | 1770 | 17 | 0.20 / 1122.19 | 2 | 2 |
4 | 12 | 1104.52 | 7 | 4.70 | 1494 | 49 | 0.25 / 1122.24 | 2 | 2 |
5 | 12 | 1152.36 | 130 | 5.74 | 1831 | 1366 | 1.62 / 1123.60 | 2 | 2 |
6 | 12 | 1159.08 | 40 | 7.73 | 1896 | 586 | 2.21 / 1124.19 | 2 | 2 |
7 | 7 | 1149.52 | 30 | 9.78 | 1934 | 567 | 2.77 / 1124.76 | 2 | 2 |
8 | 13 | 417.76 | 38 | 13.34 | 972 | 493 | 3.27 / 1125.25 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.28 | 292 | 751 | 4.02 / 1126.00 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 31 | 14.24 | 441 | 195 | 0.19 / 1118.12 | 2 | 2 |
2 | 12 | 1073.84 | 7 | 4.78 | 1807 | 60 | 0.26 / 1118.18 | 2 | 2 |
3 | 12 | 1101.52 | 130 | 7.03 | 1789 | 1635 | 1.89 / 1119.82 | 2 | 2 |
4 | 12 | 1104.44 | 40 | 8.59 | 1833 | 630 | 2.52 / 1120.45 | 2 | 2 |
5 | 7 | 1090.24 | 30 | 10.04 | 1842 | 555 | 3.07 / 1121.00 | 2 | 2 |
6 | 13 | 113.00 | 38 | 13.99 | 461 | 245 | 3.32 / 1121.25 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.28 | 287 | 738 | 4.06 / 1121.98 | 2 | 4 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 31 | 14.17 | 437 | 192 | 0.19 / 1111.80 | 2 | 2 |
2 | 3 | 909.80 | -1 | 14.17 | 437 | 0 | 0.00 / 1111.80 | 2 | 2 |
3 | 12 | 1091.64 | 7 | 10.84 | 1909 | 145 | 0.34 / 1111.94 | 2 | 2 |
4 | 12 | 1933.60 | 130 | 6.85 | 2985 | 2658 | 2.99 / 1114.60 | 2 | 2 |
5 | 12 | 1923.20 | 40 | 8.63 | 3013 | 1040 | 4.04 / 1115.64 | 2 | 2 |
6 | 7 | 1908.08 | 30 | 10.15 | 3057 | 931 | 4.97 / 1116.57 | 2 | 2 |
7 | 13 | 502.92 | 38 | 13.40 | 1144 | 583 | 5.55 / 1117.16 | 2 | 2 |
8 | 8 | 0.52 | 180 | 14.36 | 298 | 770 | 6.32 / 1117.93 | 2 | 6 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 31 | 14.15 | 404 | 177 | 0.18 / 1106.70 | 2 | 2 |
2 | 3 | 935.20 | -1 | 14.15 | 404 | 0 | 0.00 / 1106.70 | 2 | 2 |
3 | 3 | 1032.04 | 1 | 9.01 | 1750 | 16 | 0.19 / 1106.72 | 2 | 2 |
4 | 12 | 1118.36 | 130 | 7.72 | 1067 | 1071 | 1.26 / 1107.79 | 2 | 2 |
5 | 12 | 1131.16 | 40 | 5.57 | 1743 | 388 | 1.65 / 1108.18 | 2 | 2 |
6 | 7 | 1139.64 | 30 | 8.72 | 1888 | 494 | 2.15 / 1108.67 | 2 | 2 |
7 | 13 | 1218.52 | 38 | 10.83 | 2091 | 861 | 3.01 / 1109.53 | 2 | 2 |
8 | 13 | 1054.88 | 38 | 11.87 | 1885 | 850 | 3.86 / 1110.38 | 2 | 2 |
9 | 13 | 335.68 | 38 | 13.50 | 865 | 444 | 4.30 / 1110.83 | 2 | 2 |
10 | 8 | -0.08 | 180 | 14.28 | 304 | 781 | 5.08 / 1111.61 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 31 | 14.15 | 443 | 194 | 0.19 / 1102.82 | 2 | 2 |
2 | 12 | 1073.20 | 7 | 4.71 | 1502 | 50 | 0.24 / 1102.87 | 2 | 2 |
3 | 12 | 1103.08 | 130 | 5.81 | 1776 | 1341 | 1.59 / 1104.21 | 2 | 2 |
4 | 12 | 1109.60 | 40 | 7.76 | 1821 | 565 | 2.15 / 1104.77 | 2 | 2 |
5 | 7 | 1099.36 | 30 | 9.83 | 1858 | 548 | 2.70 / 1105.32 | 2 | 2 |
6 | 13 | 370.32 | 38 | 13.43 | 892 | 455 | 3.15 / 1105.78 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.29 | 291 | 749 | 3.90 / 1106.53 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 29 | 14.20 | 445 | 183 | 0.18 / 1098.74 | 2 | 2 |
2 | 3 | 1032.76 | 1 | 10.82 | 1815 | 20 | 0.20 / 1098.76 | 2 | 2 |
3 | 12 | 1091.92 | 7 | 4.78 | 1753 | 59 | 0.26 / 1098.82 | 2 | 2 |
4 | 12 | 1111.76 | 130 | 6.74 | 1819 | 1594 | 1.86 / 1100.41 | 2 | 2 |
5 | 12 | 1116.72 | 40 | 8.39 | 1852 | 622 | 2.48 / 1101.03 | 2 | 2 |
6 | 7 | 1104.44 | 30 | 10.05 | 1876 | 566 | 3.04 / 1101.60 | 2 | 2 |
7 | 13 | 144.96 | 38 | 13.92 | 520 | 275 | 3.32 / 1101.87 | 2 | 2 |
8 | 8 | -0.04 | 180 | 14.29 | 292 | 751 | 4.07 / 1102.62 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 31 | 14.17 | 443 | 195 | 0.19 / 1092.00 | 2 | 2 |
2 | 12 | 1144.56 | 7 | 10.47 | 1958 | 144 | 0.34 / 1092.14 | 2 | 2 |
3 | 12 | 2001.52 | 130 | 5.85 | 3120 | 2373 | 2.71 / 1094.51 | 2 | 2 |
4 | 12 | 1994.68 | 40 | 8.56 | 3108 | 1064 | 3.78 / 1095.58 | 2 | 2 |
5 | 7 | 1983.48 | 30 | 10.23 | 3119 | 957 | 4.73 / 1096.54 | 2 | 2 |
6 | 13 | 1013.08 | 38 | 12.85 | 1824 | 891 | 5.62 / 1097.43 | 2 | 2 |
7 | 13 | 249.28 | 38 | 13.85 | 698 | 367 | 5.99 / 1097.79 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.37 | 294 | 760 | 6.75 / 1098.55 | 2 | 5 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 31 | 14.18 | 441 | 194 | 0.19 / 1088.11 | 2 | 2 |
2 | 12 | 1066.88 | 7 | 4.70 | 1475 | 49 | 0.24 / 1088.15 | 2 | 2 |
3 | 12 | 1109.92 | 130 | 5.63 | 1779 | 1302 | 1.54 / 1089.46 | 2 | 2 |
4 | 12 | 1118.60 | 40 | 7.63 | 1839 | 561 | 2.11 / 1090.02 | 2 | 2 |
5 | 7 | 1110.40 | 30 | 10.03 | 1873 | 564 | 2.67 / 1090.58 | 2 | 2 |
6 | 13 | 379.36 | 38 | 13.43 | 909 | 464 | 3.13 / 1091.05 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.28 | 295 | 758 | 3.89 / 1091.80 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 14.17 | 425 | 175 | 0.17 / 1084.23 | 2 | 2 |
2 | 12 | 1098.16 | 7 | 4.73 | 1564 | 52 | 0.23 / 1084.28 | 2 | 2 |
3 | 12 | 1117.28 | 130 | 6.00 | 1794 | 1399 | 1.63 / 1085.68 | 2 | 2 |
4 | 12 | 1122.84 | 40 | 8.06 | 1848 | 596 | 2.22 / 1086.28 | 2 | 2 |
5 | 7 | 1111.76 | 30 | 10.18 | 1882 | 575 | 2.80 / 1086.85 | 2 | 2 |
6 | 13 | 203.72 | 38 | 13.81 | 613 | 322 | 3.12 / 1087.17 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.30 | 287 | 739 | 3.86 / 1087.91 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 30 | 14.24 | 421 | 180 | 0.18 / 1079.16 | 2 | 2 |
2 | 3 | 950.48 | -1 | 14.24 | 421 | 0 | 0.00 / 1079.16 | 2 | 2 |
3 | 3 | 1047.76 | 2 | 10.64 | 1820 | 39 | 0.22 / 1079.20 | 2 | 2 |
4 | 12 | 1104.12 | 130 | 8.53 | 1164 | 1291 | 1.51 / 1080.49 | 2 | 2 |
5 | 12 | 1119.56 | 40 | 6.70 | 1818 | 487 | 2.00 / 1080.98 | 2 | 2 |
6 | 7 | 1128.92 | 30 | 9.61 | 1894 | 546 | 2.54 / 1081.52 | 2 | 2 |
7 | 13 | 1059.16 | 38 | 11.64 | 1877 | 830 | 3.37 / 1082.36 | 2 | 2 |
8 | 13 | 841.88 | 38 | 12.44 | 1589 | 751 | 4.12 / 1083.11 | 2 | 2 |
9 | 13 | 77.04 | 38 | 14.09 | 402 | 215 | 4.34 / 1083.32 | 2 | 2 |
10 | 8 | 0.40 | 180 | 14.31 | 285 | 734 | 5.07 / 1084.06 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 14.15 | 428 | 176 | 0.18 / 1073.00 | 2 | 2 |
2 | 3 | 1028.84 | 1 | 10.64 | 1794 | 19 | 0.19 / 1073.02 | 2 | 2 |
3 | 3 | 1017.76 | 1 | 9.90 | 1765 | 17 | 0.21 / 1073.03 | 2 | 2 |
4 | 12 | 1075.76 | 7 | 10.60 | 1878 | 139 | 0.35 / 1073.17 | 2 | 2 |
5 | 12 | 1948.92 | 130 | 6.40 | 2974 | 2474 | 2.83 / 1075.65 | 2 | 2 |
6 | 12 | 1940.84 | 40 | 8.42 | 3034 | 1022 | 3.85 / 1076.67 | 2 | 2 |
7 | 7 | 1927.92 | 30 | 10.18 | 3045 | 930 | 4.78 / 1077.60 | 2 | 2 |
8 | 13 | 608.96 | 38 | 13.30 | 1260 | 637 | 5.41 / 1078.24 | 2 | 2 |
9 | 8 | 0.24 | 180 | 14.38 | 288 | 745 | 6.16 / 1078.98 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 31 | 14.17 | 432 | 190 | 0.19 / 1068.99 | 2 | 2 |
2 | 12 | 1083.32 | 7 | 4.71 | 1507 | 50 | 0.24 / 1069.04 | 2 | 2 |
3 | 12 | 1104.36 | 130 | 5.70 | 1761 | 1305 | 1.54 / 1070.34 | 2 | 2 |
4 | 12 | 1112.08 | 40 | 7.69 | 1821 | 560 | 2.10 / 1070.90 | 2 | 2 |
5 | 7 | 1102.84 | 30 | 10.06 | 1874 | 566 | 2.67 / 1071.47 | 2 | 2 |
6 | 13 | 366.32 | 38 | 13.45 | 878 | 449 | 3.12 / 1071.92 | 2 | 2 |
7 | 13 | 6.76 | 38 | 14.22 | 292 | 158 | 3.28 / 1072.08 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.28 | 290 | 745 | 4.02 / 1072.82 | 2 | 15 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 30 | 14.16 | 431 | 183 | 0.18 / 1065.15 | 2 | 2 |
2 | 12 | 1073.32 | 7 | 4.72 | 1528 | 50 | 0.23 / 1065.20 | 2 | 2 |
3 | 12 | 1112.00 | 130 | 6.07 | 1774 | 1400 | 1.63 / 1066.60 | 2 | 2 |
4 | 12 | 1119.92 | 40 | 7.91 | 1834 | 580 | 2.21 / 1067.18 | 2 | 2 |
5 | 7 | 1110.72 | 30 | 10.11 | 1888 | 573 | 2.79 / 1067.75 | 2 | 2 |
6 | 13 | 203.48 | 38 | 13.79 | 611 | 320 | 3.11 / 1068.07 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.29 | 282 | 725 | 3.83 / 1068.80 | 2 | 4 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 30 | 14.25 | 424 | 181 | 0.18 / 1061.03 | 2 | 2 |
2 | 12 | 1064.92 | 7 | 4.80 | 1882 | 63 | 0.24 / 1061.09 | 2 | 2 |
3 | 12 | 1108.48 | 130 | 7.21 | 1799 | 1686 | 1.93 / 1062.78 | 2 | 2 |
4 | 12 | 1112.56 | 40 | 8.56 | 1840 | 630 | 2.56 / 1063.41 | 2 | 2 |
5 | 7 | 1099.88 | 30 | 10.29 | 1856 | 573 | 3.13 / 1063.98 | 2 | 2 |
6 | 13 | 126.48 | 38 | 13.95 | 482 | 256 | 3.39 / 1064.23 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.27 | 286 | 735 | 4.12 / 1064.97 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 28 | 14.16 | 397 | 157 | 0.16 / 1054.08 | 2 | 2 |
2 | 3 | 1022.24 | 1 | 7.95 | 1713 | 14 | 0.17 / 1054.09 | 2 | 2 |
3 | 12 | 1098.36 | 7 | 9.49 | 1893 | 126 | 0.30 / 1054.22 | 2 | 2 |
4 | 12 | 1960.20 | 130 | 5.23 | 3015 | 2050 | 2.35 / 1056.27 | 2 | 2 |
5 | 12 | 1955.04 | 40 | 8.10 | 3052 | 989 | 3.34 / 1057.26 | 2 | 2 |
6 | 7 | 1945.88 | 30 | 10.16 | 3070 | 936 | 4.27 / 1058.19 | 2 | 2 |
7 | 13 | 1508.52 | 38 | 12.18 | 2516 | 1165 | 5.44 / 1059.36 | 2 | 2 |
8 | 13 | 748.24 | 38 | 13.12 | 1490 | 743 | 6.18 / 1060.10 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.38 | 288 | 745 | 6.92 / 1060.84 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 31 | 14.13 | 421 | 184 | 0.18 / 1050.29 | 2 | 2 |
2 | 12 | 1070.88 | 7 | 4.72 | 1551 | 51 | 0.24 / 1050.34 | 2 | 2 |
3 | 12 | 1103.96 | 130 | 6.13 | 1761 | 1403 | 1.64 / 1051.75 | 2 | 2 |
4 | 12 | 1109.20 | 40 | 7.77 | 1818 | 565 | 2.20 / 1052.31 | 2 | 2 |
5 | 7 | 1097.88 | 30 | 10.21 | 1844 | 565 | 2.77 / 1052.88 | 2 | 2 |
6 | 13 | 183.00 | 38 | 13.79 | 594 | 311 | 3.08 / 1053.19 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.26 | 285 | 732 | 3.81 / 1053.92 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 30 | 14.21 | 416 | 177 | 0.18 / 1046.39 | 2 | 2 |
2 | 12 | 1063.52 | 7 | 4.76 | 1691 | 56 | 0.23 / 1046.45 | 2 | 2 |
3 | 12 | 1108.88 | 130 | 6.39 | 1790 | 1487 | 1.72 / 1047.93 | 2 | 2 |
4 | 12 | 1115.00 | 40 | 8.00 | 1828 | 585 | 2.31 / 1048.52 | 2 | 2 |
5 | 7 | 1104.56 | 30 | 10.15 | 1881 | 573 | 2.88 / 1049.09 | 2 | 2 |
6 | 13 | 165.88 | 38 | 13.82 | 544 | 286 | 3.16 / 1049.38 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.25 | 285 | 731 | 3.90 / 1050.11 | 2 | 2 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 30 | 14.23 | 427 | 182 | 0.18 / 1042.66 | 2 | 2 |
2 | 12 | 1111.68 | 130 | 7.42 | 1819 | 1755 | 1.94 / 1044.41 | 2 | 2 |
3 | 7 | 1109.96 | 30 | 10.30 | 1897 | 586 | 2.52 / 1045.00 | 2 | 2 |
4 | 13 | 385.68 | 38 | 13.35 | 926 | 470 | 2.99 / 1045.47 | 2 | 2 |
5 | 8 | -0.16 | 180 | 14.28 | 290 | 745 | 3.74 / 1046.21 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 32 | 14.18 | 411 | 186 | 0.19 / 1036.72 | 2 | 2 |
2 | 3 | 899.84 | -1 | 14.18 | 411 | 0 | 0.00 / 1036.72 | 2 | 2 |
3 | 12 | 1106.52 | 7 | 10.85 | 1894 | 144 | 0.33 / 1036.86 | 2 | 2 |
4 | 12 | 2002.32 | 130 | 7.08 | 3052 | 2809 | 3.14 / 1039.67 | 2 | 2 |
5 | 7 | 1986.60 | 30 | 10.07 | 3139 | 948 | 4.09 / 1040.62 | 2 | 2 |
6 | 13 | 994.60 | 38 | 12.77 | 1822 | 884 | 4.97 / 1041.50 | 2 | 2 |
7 | 13 | 105.48 | 38 | 14.11 | 447 | 240 | 5.21 / 1041.74 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.36 | 284 | 734 | 5.95 / 1042.48 | 2 | 3 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 30 | 14.22 | 408 | 174 | 0.17 / 1032.68 | 2 | 2 |
2 | 3 | 1012.24 | 1 | 9.47 | 1782 | 17 | 0.19 / 1032.70 | 2 | 2 |
3 | 12 | 1120.64 | 130 | 5.46 | 1791 | 1271 | 1.46 / 1033.97 | 2 | 2 |
4 | 7 | 1135.56 | 30 | 9.89 | 1922 | 570 | 2.03 / 1034.54 | 2 | 2 |
5 | 13 | 993.96 | 38 | 12.17 | 1781 | 824 | 2.86 / 1035.37 | 2 | 2 |
6 | 13 | 325.48 | 38 | 13.52 | 832 | 427 | 3.28 / 1035.79 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.29 | 286 | 736 | 4.02 / 1036.53 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 14.19 | 402 | 171 | 0.17 / 1028.81 | 2 | 2 |
2 | 12 | 1096.32 | 130 | 5.82 | 1749 | 1323 | 1.49 / 1030.13 | 2 | 2 |
3 | 7 | 1106.52 | 30 | 9.98 | 1883 | 564 | 2.06 / 1030.70 | 2 | 2 |
4 | 13 | 919.44 | 38 | 12.19 | 1678 | 777 | 2.84 / 1031.47 | 2 | 2 |
5 | 13 | 204.52 | 38 | 13.78 | 601 | 315 | 3.15 / 1031.79 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.29 | 281 | 723 | 3.87 / 1032.51 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 30 | 14.27 | 415 | 178 | 0.18 / 1024.89 | 2 | 2 |
2 | 12 | 1109.68 | 130 | 7.44 | 1821 | 1761 | 1.94 / 1026.65 | 2 | 2 |
3 | 7 | 1108.76 | 30 | 10.38 | 1890 | 589 | 2.53 / 1027.24 | 2 | 2 |
4 | 13 | 397.60 | 38 | 13.35 | 942 | 478 | 3.01 / 1027.72 | 2 | 2 |
5 | 13 | 24.16 | 38 | 14.19 | 323 | 174 | 3.18 / 1027.89 | 2 | 2 |
6 | 8 | -0.28 | 180 | 14.28 | 291 | 748 | 3.93 / 1028.64 | 2 | 4 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 29 | 14.19 | 419 | 172 | 0.17 / 1018.87 | 2 | 2 |
2 | 3 | 1055.60 | 2 | 11.07 | 1845 | 41 | 0.21 / 1018.91 | 2 | 2 |
3 | 3 | 1025.00 | 1 | 10.60 | 1799 | 19 | 0.23 / 1018.93 | 2 | 2 |
4 | 12 | 1115.84 | 7 | 10.74 | 1950 | 147 | 0.38 / 1019.08 | 2 | 2 |
5 | 12 | 2001.64 | 130 | 6.91 | 3051 | 2741 | 3.12 / 1021.82 | 2 | 2 |
6 | 7 | 1986.56 | 30 | 10.07 | 3137 | 948 | 4.07 / 1022.77 | 2 | 2 |
7 | 13 | 992.36 | 38 | 12.76 | 1804 | 875 | 4.94 / 1023.64 | 2 | 2 |
8 | 13 | 201.60 | 38 | 13.90 | 613 | 324 | 5.27 / 1023.97 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.35 | 288 | 744 | 6.01 / 1024.71 | 2 | 3 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 30 | 14.21 | 410 | 175 | 0.17 / 1014.94 | 2 | 2 |
2 | 12 | 1111.52 | 130 | 6.21 | 1784 | 1440 | 1.62 / 1016.38 | 2 | 2 |
3 | 7 | 1118.40 | 30 | 10.23 | 1901 | 583 | 2.20 / 1016.97 | 2 | 2 |
4 | 13 | 907.72 | 38 | 12.40 | 1672 | 788 | 2.99 / 1017.75 | 2 | 2 |
5 | 13 | 89.24 | 38 | 14.07 | 421 | 225 | 3.21 / 1017.98 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.31 | 280 | 721 | 3.93 / 1018.70 | 2 | 2 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 30 | 14.15 | 434 | 184 | 0.18 / 1010.86 | 2 | 2 |
2 | 12 | 1135.72 | 130 | 5.98 | 1836 | 1427 | 1.61 / 1012.29 | 2 | 2 |
3 | 7 | 1147.76 | 30 | 10.17 | 1944 | 593 | 2.20 / 1012.88 | 2 | 2 |
4 | 13 | 952.80 | 38 | 12.30 | 1750 | 818 | 3.02 / 1013.70 | 2 | 2 |
5 | 13 | 221.68 | 38 | 13.77 | 642 | 336 | 3.36 / 1014.04 | 2 | 2 |
6 | 8 | 0.00 | 180 | 14.30 | 284 | 731 | 4.09 / 1014.77 | 2 | 2 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 30 | 14.23 | 391 | 167 | 0.17 / 1007.02 | 2 | 2 |
2 | 12 | 1102.40 | 120 | 7.10 | 1800 | 1534 | 1.70 / 1008.55 | 2 | 2 |
3 | 7 | 1102.52 | 30 | 10.38 | 1882 | 586 | 2.29 / 1009.14 | 2 | 2 |
4 | 13 | 633.04 | 38 | 12.93 | 1288 | 633 | 2.92 / 1009.77 | 2 | 2 |
5 | 13 | 36.00 | 38 | 14.17 | 335 | 180 | 3.10 / 1009.95 | 2 | 2 |
6 | 8 | -0.28 | 180 | 14.29 | 283 | 728 | 3.83 / 1010.68 | 2 | 2 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 30 | 14.18 | 414 | 176 | 0.18 / 1001.14 | 2 | 2 |
2 | 3 | 953.20 | -1 | 14.18 | 414 | 0 | 0.00 / 1001.14 | 2 | 2 |
3 | 3 | 1043.88 | 2 | 11.02 | 1831 | 40 | 0.22 / 1001.18 | 2 | 2 |
4 | 12 | 1127.64 | 7 | 11.13 | 1922 | 150 | 0.37 / 1001.33 | 2 | 2 |
5 | 12 | 2002.52 | 120 | 7.36 | 3054 | 2697 | 3.06 / 1004.03 | 2 | 2 |
6 | 7 | 1987.96 | 30 | 10.10 | 3123 | 946 | 4.01 / 1004.97 | 2 | 2 |
7 | 13 | 998.36 | 38 | 12.76 | 1839 | 892 | 4.90 / 1005.87 | 2 | 2 |
8 | 13 | 97.96 | 38 | 14.10 | 453 | 243 | 5.14 / 1006.11 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.36 | 287 | 742 | 5.89 / 1006.85 | 2 | 2 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 30 | 14.25 | 393 | 168 | 0.17 / 997.23 | 2 | 2 |
2 | 12 | 1119.20 | 120 | 5.64 | 1783 | 1207 | 1.37 / 998.44 | 2 | 2 |
3 | 7 | 1131.04 | 30 | 10.02 | 1927 | 579 | 1.95 / 999.02 | 2 | 2 |
4 | 13 | 963.76 | 38 | 12.27 | 1750 | 816 | 2.77 / 999.83 | 2 | 2 |
5 | 13 | 262.72 | 38 | 13.66 | 727 | 377 | 3.15 / 1000.21 | 2 | 2 |
6 | 8 | -0.24 | 180 | 14.28 | 293 | 753 | 3.90 / 1000.96 | 2 | 2 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 29 | 14.18 | 396 | 163 | 0.16 / 993.30 | 2 | 2 |
2 | 3 | 1019.12 | 1 | 8.29 | 1741 | 14 | 0.18 / 993.32 | 2 | 2 |
3 | 3 | 1012.84 | 1 | 7.52 | 1685 | 13 | 0.19 / 993.33 | 2 | 2 |
4 | 12 | 1129.76 | 120 | 5.62 | 1777 | 1198 | 1.39 / 994.53 | 2 | 2 |
5 | 7 | 1143.16 | 30 | 10.05 | 1950 | 588 | 1.98 / 995.12 | 2 | 2 |
6 | 13 | 982.60 | 38 | 12.25 | 1771 | 824 | 2.80 / 995.94 | 2 | 2 |
7 | 13 | 284.64 | 38 | 13.64 | 739 | 383 | 3.18 / 996.33 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.30 | 287 | 739 | 3.92 / 997.06 | 2 | 4 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 31 | 14.23 | 390 | 172 | 0.17 / 989.35 | 2 | 2 |
2 | 3 | 951.56 | -1 | 14.23 | 390 | 0 | 0.00 / 989.35 | 2 | 2 |
3 | 3 | 1039.12 | 2 | 9.87 | 1773 | 35 | 0.21 / 989.39 | 2 | 2 |
4 | 12 | 1118.96 | 120 | 7.00 | 1819 | 1528 | 1.73 / 990.91 | 2 | 2 |
5 | 7 | 1121.20 | 30 | 10.44 | 1901 | 595 | 2.33 / 991.51 | 2 | 2 |
6 | 13 | 686.32 | 38 | 12.88 | 1366 | 669 | 3.00 / 992.18 | 2 | 2 |
7 | 13 | 70.24 | 38 | 14.09 | 404 | 216 | 3.22 / 992.39 | 2 | 2 |
8 | 8 | 0.00 | 180 | 14.28 | 291 | 748 | 3.96 / 993.14 | 2 | 4 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 30 | 14.21 | 408 | 174 | 0.17 / 983.65 | 2 | 2 |
2 | 12 | 1105.12 | 7 | 10.25 | 1895 | 136 | 0.31 / 983.78 | 2 | 2 |
3 | 12 | 2002.52 | 120 | 6.87 | 3062 | 2524 | 2.83 / 986.31 | 2 | 2 |
4 | 7 | 1991.16 | 30 | 10.20 | 3120 | 955 | 3.79 / 987.26 | 2 | 2 |
5 | 13 | 1031.00 | 38 | 12.75 | 1863 | 903 | 4.69 / 988.16 | 2 | 2 |
6 | 13 | 152.76 | 38 | 14.02 | 525 | 280 | 4.97 / 988.44 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.37 | 284 | 735 | 5.71 / 989.18 | 2 | 2 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 30 | 14.18 | 418 | 178 | 0.18 / 979.77 | 2 | 2 |
2 | 12 | 1109.00 | 120 | 6.08 | 1773 | 1294 | 1.47 / 981.07 | 2 | 2 |
3 | 7 | 1116.08 | 30 | 10.27 | 1900 | 585 | 2.06 / 981.65 | 2 | 2 |
4 | 13 | 914.52 | 38 | 12.43 | 1695 | 801 | 2.86 / 982.45 | 2 | 2 |
5 | 13 | 178.64 | 38 | 13.91 | 558 | 295 | 3.15 / 982.75 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.31 | 281 | 724 | 3.88 / 983.47 | 2 | 2 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 31 | 14.18 | 429 | 189 | 0.19 / 975.82 | 2 | 2 |
2 | 12 | 1107.64 | 120 | 6.37 | 1803 | 1378 | 1.57 / 977.19 | 2 | 2 |
3 | 7 | 1117.72 | 30 | 10.37 | 1906 | 593 | 2.16 / 977.79 | 2 | 2 |
4 | 13 | 921.40 | 38 | 12.47 | 1691 | 801 | 2.96 / 978.59 | 2 | 2 |
5 | 13 | 156.92 | 38 | 13.95 | 527 | 279 | 3.24 / 978.87 | 2 | 2 |
6 | 8 | -0.24 | 180 | 14.32 | 283 | 729 | 3.97 / 979.60 | 2 | 4 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 31 | 14.27 | 420 | 186 | 0.19 / 972.07 | 2 | 2 |
2 | 12 | 1095.96 | 100 | 7.70 | 1804 | 1389 | 1.57 / 973.46 | 2 | 2 |
3 | 7 | 1098.36 | 30 | 10.67 | 1877 | 601 | 2.18 / 974.06 | 2 | 2 |
4 | 13 | 653.88 | 38 | 13.00 | 1315 | 650 | 2.83 / 974.71 | 2 | 2 |
5 | 13 | 34.28 | 38 | 14.23 | 332 | 180 | 3.00 / 974.89 | 2 | 2 |
6 | 8 | -0.08 | 180 | 14.33 | 286 | 738 | 3.74 / 975.63 | 2 | 3 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 30 | 14.19 | 426 | 181 | 0.18 / 966.35 | 2 | 2 |
2 | 12 | 1110.64 | 7 | 11.22 | 1933 | 152 | 0.33 / 966.50 | 2 | 2 |
3 | 12 | 2002.20 | 100 | 8.27 | 3090 | 2555 | 2.89 / 969.06 | 2 | 2 |
4 | 7 | 1989.56 | 30 | 10.25 | 3117 | 958 | 3.85 / 970.02 | 2 | 2 |
5 | 13 | 987.04 | 38 | 12.86 | 1800 | 880 | 4.73 / 970.90 | 2 | 2 |
6 | 13 | 94.08 | 38 | 14.15 | 451 | 243 | 4.97 / 971.14 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.39 | 288 | 746 | 5.72 / 971.88 | 2 | 2 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 30 | 14.15 | 409 | 174 | 0.17 / 962.06 | 2 | 2 |
2 | 12 | 1115.84 | 100 | 5.13 | 1780 | 913 | 1.09 / 962.97 | 2 | 2 |
3 | 7 | 1130.92 | 30 | 9.85 | 1913 | 565 | 1.65 / 963.54 | 2 | 2 |
4 | 13 | 1087.28 | 38 | 12.06 | 1915 | 878 | 2.53 / 964.41 | 2 | 2 |
5 | 13 | 879.32 | 38 | 12.68 | 1642 | 791 | 3.32 / 965.21 | 2 | 2 |
6 | 13 | 77.92 | 38 | 14.12 | 406 | 218 | 3.54 / 965.42 | 2 | 2 |
7 | 8 | -0.08 | 180 | 14.33 | 289 | 745 | 4.28 / 966.17 | 2 | 5 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 31 | 14.18 | 417 | 183 | 0.18 / 958.25 | 2 | 2 |
2 | 12 | 1115.44 | 100 | 5.59 | 1798 | 1005 | 1.19 / 959.25 | 2 | 2 |
3 | 7 | 1128.08 | 30 | 10.01 | 1925 | 578 | 1.77 / 959.83 | 2 | 2 |
4 | 13 | 1005.28 | 38 | 12.21 | 1815 | 842 | 2.61 / 960.67 | 2 | 2 |
5 | 13 | 373.20 | 38 | 13.48 | 899 | 461 | 3.07 / 961.13 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.32 | 292 | 753 | 3.82 / 961.88 | 2 | 2 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 31 | 14.27 | 439 | 194 | 0.19 / 954.52 | 2 | 2 |
2 | 12 | 1098.88 | 100 | 7.52 | 1815 | 1365 | 1.56 / 955.89 | 2 | 2 |
3 | 7 | 1101.00 | 30 | 10.68 | 1895 | 607 | 2.17 / 956.50 | 2 | 2 |
4 | 13 | 652.44 | 38 | 13.03 | 1315 | 651 | 2.82 / 957.15 | 2 | 2 |
5 | 13 | 31.56 | 38 | 14.24 | 329 | 178 | 3.00 / 957.32 | 2 | 2 |
6 | 8 | -0.20 | 180 | 14.34 | 286 | 738 | 3.73 / 958.06 | 2 | 2 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 28 | 14.22 | 425 | 169 | 0.17 / 948.69 | 2 | 2 |
2 | 3 | 1046.64 | 2 | 11.41 | 1845 | 42 | 0.21 / 948.73 | 2 | 2 |
3 | 12 | 1125.16 | 6 | 11.30 | 1959 | 133 | 0.34 / 948.87 | 2 | 2 |
4 | 12 | 2003.76 | 100 | 8.60 | 3097 | 2663 | 3.01 / 951.53 | 2 | 2 |
5 | 7 | 1991.84 | 30 | 10.35 | 3118 | 968 | 3.98 / 952.50 | 2 | 2 |
6 | 13 | 898.40 | 38 | 12.95 | 1706 | 840 | 4.82 / 953.34 | 2 | 2 |
7 | 13 | 79.16 | 38 | 14.19 | 430 | 232 | 5.05 / 953.57 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.39 | 293 | 759 | 5.81 / 954.33 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 25 | 14.23 | 433 | 154 | 0.15 / 944.69 | 2 | 2 |
2 | 10 | 1005.88 | 7 | 12.38 | 1810 | 157 | 0.31 / 944.85 | 2 | 2 |
3 | 12 | 1124.08 | 100 | 6.09 | 1826 | 1112 | 1.42 / 945.96 | 2 | 2 |
4 | 7 | 1135.56 | 30 | 10.33 | 1939 | 601 | 2.02 / 946.56 | 2 | 2 |
5 | 13 | 969.20 | 38 | 12.53 | 1777 | 846 | 2.87 / 947.41 | 2 | 2 |
6 | 13 | 249.52 | 38 | 13.76 | 697 | 364 | 3.23 / 947.77 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.33 | 292 | 753 | 3.99 / 948.52 | 2 | 5 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 14.23 | 435 | 180 | 0.18 / 940.89 | 2 | 2 |
2 | 3 | 1027.16 | 1 | 11.10 | 1819 | 20 | 0.20 / 940.91 | 2 | 2 |
3 | 12 | 1126.28 | 100 | 6.24 | 1825 | 1139 | 1.34 / 942.05 | 2 | 2 |
4 | 7 | 1134.60 | 30 | 10.35 | 1944 | 604 | 1.94 / 942.65 | 2 | 2 |
5 | 13 | 942.28 | 38 | 12.65 | 1720 | 827 | 2.77 / 943.48 | 2 | 2 |
6 | 13 | 204.60 | 38 | 13.89 | 609 | 321 | 3.09 / 943.80 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.36 | 284 | 734 | 3.82 / 944.54 | 2 | 4 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 28 | 14.30 | 411 | 165 | 0.16 / 937.26 | 2 | 2 |
2 | 3 | 1029.28 | 1 | 11.61 | 1814 | 21 | 0.19 / 937.28 | 2 | 2 |
3 | 12 | 1119.00 | 60 | 7.65 | 1844 | 846 | 1.03 / 938.13 | 2 | 2 |
4 | 7 | 1126.52 | 30 | 10.68 | 1926 | 617 | 1.65 / 938.75 | 2 | 2 |
5 | 13 | 961.96 | 38 | 12.54 | 1753 | 835 | 2.48 / 939.58 | 2 | 2 |
6 | 13 | 252.76 | 38 | 13.78 | 714 | 374 | 2.86 / 939.96 | 2 | 2 |
7 | 8 | -0.36 | 180 | 14.34 | 293 | 756 | 3.61 / 940.71 | 2 | 3 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 30 | 14.32 | 415 | 178 | 0.18 / 932.16 | 2 | 2 |
2 | 3 | 946.36 | -1 | 14.32 | 415 | 0 | 0.00 / 932.16 | 2 | 2 |
3 | 3 | 1030.92 | 1 | 10.91 | 1792 | 20 | 0.20 / 932.18 | 2 | 2 |
4 | 12 | 1126.92 | 5 | 11.23 | 1981 | 111 | 0.31 / 932.29 | 2 | 2 |
5 | 12 | 2002.96 | 60 | 9.72 | 3123 | 1821 | 2.13 / 934.11 | 2 | 2 |
6 | 7 | 1994.96 | 30 | 10.52 | 3142 | 992 | 3.12 / 935.10 | 2 | 2 |
7 | 13 | 1083.52 | 38 | 12.92 | 1950 | 957 | 4.08 / 936.06 | 2 | 2 |
8 | 13 | 188.24 | 38 | 14.02 | 582 | 310 | 4.39 / 936.37 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.43 | 281 | 730 | 5.12 / 937.10 | 2 | 3 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 30 | 14.30 | 417 | 179 | 0.18 / 924.92 | 2 | 2 |
2 | 3 | 941.68 | -1 | 14.30 | 417 | 0 | 0.00 / 924.92 | 2 | 2 |
3 | 3 | 1034.72 | 1 | 10.90 | 1828 | 20 | 0.20 / 924.94 | 2 | 2 |
4 | 12 | 1111.04 | 22 | 7.59 | 1818 | 304 | 0.50 / 925.24 | 2 | 2 |
5 | 12 | 1964.36 | 120 | 4.89 | 2715 | 1593 | 2.10 / 926.83 | 2 | 2 |
6 | 12 | 1964.64 | 60 | 6.09 | 3041 | 1111 | 3.21 / 927.94 | 2 | 2 |
7 | 7 | 1960.24 | 30 | 10.07 | 3116 | 941 | 4.15 / 928.89 | 2 | 2 |
8 | 13 | 1756.92 | 38 | 12.10 | 2872 | 1321 | 5.47 / 930.21 | 2 | 2 |
9 | 13 | 833.76 | 38 | 13.16 | 1613 | 807 | 6.28 / 931.01 | 2 | 2 |
10 | 13 | 76.16 | 38 | 14.22 | 410 | 222 | 6.50 / 931.23 | 2 | 2 |
11 | 8 | -0.12 | 180 | 14.44 | 286 | 743 | 7.24 / 931.98 | 2 | 3 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 30 | 14.29 | 425 | 182 | 0.18 / 917.60 | 2 | 2 |
2 | 12 | 1130.04 | 22 | 6.90 | 1845 | 280 | 0.46 / 917.88 | 2 | 2 |
3 | 12 | 2000.00 | 120 | 4.87 | 2589 | 1513 | 1.98 / 919.39 | 2 | 2 |
4 | 12 | 2000.00 | 60 | 5.66 | 2966 | 1007 | 2.98 / 920.40 | 2 | 2 |
5 | 7 | 1996.24 | 30 | 9.98 | 3146 | 942 | 3.92 / 921.34 | 2 | 2 |
6 | 13 | 1813.04 | 38 | 11.99 | 2959 | 1348 | 5.27 / 922.69 | 2 | 2 |
7 | 13 | 1116.40 | 38 | 12.89 | 2006 | 983 | 6.26 / 923.67 | 2 | 2 |
8 | 13 | 171.40 | 38 | 14.02 | 580 | 309 | 6.56 / 923.98 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.41 | 291 | 755 | 7.32 / 924.74 | 2 | 2 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 30 | 14.33 | 415 | 178 | 0.18 / 910.79 | 2 | 2 |
2 | 12 | 1087.00 | 22 | 7.45 | 1792 | 294 | 0.47 / 911.08 | 2 | 2 |
3 | 12 | 1966.92 | 100 | 4.88 | 2601 | 1269 | 1.74 / 912.35 | 2 | 2 |
4 | 12 | 1966.36 | 50 | 5.90 | 2926 | 863 | 2.60 / 913.21 | 2 | 2 |
5 | 7 | 1961.96 | 30 | 9.93 | 3093 | 921 | 3.53 / 914.14 | 2 | 2 |
6 | 13 | 1779.20 | 38 | 11.99 | 2906 | 1324 | 4.85 / 915.46 | 2 | 2 |
7 | 13 | 1064.72 | 38 | 12.95 | 1903 | 936 | 5.79 / 916.40 | 2 | 2 |
8 | 13 | 152.40 | 38 | 14.09 | 525 | 281 | 6.07 / 916.68 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.43 | 285 | 740 | 6.81 / 917.42 | 2 | 2 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 30 | 14.33 | 425 | 183 | 0.18 / 903.79 | 2 | 2 |
2 | 12 | 1125.08 | 22 | 7.06 | 1868 | 290 | 0.47 / 904.08 | 2 | 2 |
3 | 12 | 1986.80 | 100 | 4.90 | 2699 | 1323 | 1.80 / 905.41 | 2 | 2 |
4 | 12 | 1987.36 | 50 | 6.12 | 3021 | 924 | 2.72 / 906.33 | 2 | 2 |
5 | 7 | 1984.12 | 30 | 10.07 | 3121 | 943 | 3.66 / 907.27 | 2 | 2 |
6 | 13 | 1812.24 | 38 | 12.04 | 2927 | 1339 | 5.00 / 908.61 | 2 | 2 |
7 | 13 | 1094.12 | 38 | 12.92 | 1961 | 963 | 5.96 / 909.58 | 2 | 2 |
8 | 13 | 160.60 | 38 | 14.07 | 545 | 291 | 6.26 / 909.87 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.43 | 286 | 743 | 7.00 / 910.61 | 2 | 3 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 30 | 14.32 | 435 | 187 | 0.19 / 896.80 | 2 | 2 |
2 | 12 | 1133.40 | 22 | 7.07 | 1856 | 289 | 0.48 / 897.09 | 2 | 2 |
3 | 12 | 1992.64 | 100 | 4.91 | 2725 | 1338 | 1.81 / 898.43 | 2 | 2 |
4 | 12 | 1992.84 | 50 | 6.28 | 3060 | 961 | 2.77 / 899.39 | 2 | 2 |
5 | 7 | 1988.40 | 30 | 10.15 | 3139 | 956 | 3.73 / 900.34 | 2 | 2 |
6 | 13 | 1784.88 | 38 | 12.15 | 2893 | 1336 | 5.07 / 901.68 | 2 | 2 |
7 | 13 | 1051.12 | 38 | 13.00 | 1881 | 929 | 6.00 / 902.61 | 2 | 2 |
8 | 13 | 131.28 | 38 | 14.15 | 493 | 265 | 6.26 / 902.87 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.44 | 284 | 738 | 7.00 / 903.61 | 2 | 2 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 30 | 14.33 | 418 | 180 | 0.18 / 890.03 | 2 | 2 |
2 | 3 | 941.40 | -1 | 14.33 | 418 | 0 | 0.00 / 890.03 | 2 | 2 |
3 | 3 | 1036.08 | 1 | 11.17 | 1856 | 21 | 0.20 / 890.05 | 2 | 2 |
4 | 12 | 1131.84 | 19 | 7.65 | 1836 | 267 | 0.47 / 890.31 | 2 | 2 |
5 | 12 | 2003.24 | 80 | 4.96 | 2896 | 1149 | 1.62 / 891.46 | 2 | 2 |
6 | 12 | 2004.60 | 50 | 6.76 | 3095 | 1046 | 2.66 / 892.51 | 2 | 2 |
7 | 7 | 2000.60 | 30 | 10.18 | 3171 | 968 | 3.63 / 893.48 | 2 | 2 |
8 | 13 | 1797.40 | 38 | 12.13 | 2916 | 1344 | 4.98 / 894.82 | 2 | 2 |
9 | 13 | 853.52 | 38 | 13.17 | 1632 | 817 | 5.79 / 895.64 | 2 | 2 |
10 | 13 | 83.48 | 38 | 14.24 | 417 | 226 | 6.02 / 895.86 | 2 | 2 |
11 | 8 | -0.04 | 180 | 14.44 | 288 | 749 | 6.77 / 896.61 | 2 | 3 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 30 | 14.33 | 432 | 186 | 0.19 / 883.42 | 2 | 2 |
2 | 3 | 970.80 | -1 | 14.33 | 432 | 0 | 0.00 / 883.42 | 2 | 2 |
3 | 3 | 1053.72 | 1 | 11.49 | 1863 | 21 | 0.21 / 883.44 | 2 | 2 |
4 | 12 | 1153.36 | 19 | 7.67 | 1874 | 273 | 0.48 / 883.72 | 2 | 2 |
5 | 12 | 2000.56 | 80 | 4.97 | 2945 | 1171 | 1.65 / 884.89 | 2 | 2 |
6 | 12 | 2002.40 | 50 | 7.23 | 3071 | 1110 | 2.76 / 886.00 | 2 | 2 |
7 | 7 | 1998.12 | 30 | 10.29 | 3155 | 974 | 3.74 / 886.97 | 2 | 2 |
8 | 13 | 1578.08 | 38 | 12.43 | 2612 | 1234 | 4.97 / 888.21 | 2 | 2 |
9 | 13 | 649.16 | 38 | 13.39 | 1328 | 676 | 5.64 / 888.88 | 2 | 2 |
10 | 13 | 75.56 | 38 | 14.24 | 406 | 220 | 5.86 / 889.10 | 2 | 2 |
11 | 8 | -0.16 | 180 | 14.42 | 287 | 745 | 6.61 / 889.85 | 2 | 3 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 31 | 14.32 | 434 | 193 | 0.19 / 877.02 | 2 | 2 |
2 | 3 | 958.80 | -1 | 14.32 | 434 | 0 | 0.00 / 877.02 | 2 | 2 |
3 | 3 | 1046.12 | 1 | 11.52 | 1862 | 21 | 0.21 / 877.04 | 2 | 2 |
4 | 12 | 1150.32 | 17 | 7.91 | 1868 | 251 | 0.47 / 877.29 | 2 | 2 |
5 | 12 | 2004.48 | 70 | 4.99 | 2990 | 1044 | 1.51 / 878.33 | 2 | 2 |
6 | 12 | 2006.36 | 46 | 7.70 | 3081 | 1091 | 2.60 / 879.42 | 2 | 2 |
7 | 7 | 2002.60 | 30 | 10.34 | 3147 | 976 | 3.58 / 880.40 | 2 | 2 |
8 | 13 | 1577.08 | 38 | 12.44 | 2608 | 1233 | 4.81 / 881.63 | 2 | 2 |
9 | 13 | 642.52 | 38 | 13.40 | 1306 | 665 | 5.48 / 882.30 | 2 | 2 |
10 | 13 | 36.36 | 38 | 14.34 | 341 | 186 | 5.66 / 882.48 | 2 | 2 |
11 | 8 | -0.20 | 180 | 14.43 | 290 | 753 | 6.41 / 883.24 | 2 | 3 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 31 | 14.34 | 426 | 189 | 0.19 / 870.65 | 2 | 2 |
2 | 3 | 969.04 | -1 | 14.34 | 426 | 0 | 0.00 / 870.65 | 2 | 2 |
3 | 3 | 1056.56 | 1 | 11.89 | 1886 | 22 | 0.21 / 870.68 | 2 | 2 |
4 | 12 | 1141.56 | 17 | 8.04 | 1895 | 259 | 0.47 / 870.94 | 2 | 2 |
5 | 12 | 2002.20 | 70 | 5.00 | 3080 | 1078 | 1.55 / 872.01 | 2 | 2 |
6 | 12 | 2004.20 | 46 | 8.38 | 3103 | 1196 | 2.74 / 873.21 | 2 | 2 |
7 | 7 | 2000.04 | 30 | 10.41 | 3185 | 995 | 3.74 / 874.20 | 2 | 2 |
8 | 13 | 1580.04 | 38 | 12.47 | 2616 | 1240 | 4.98 / 875.44 | 2 | 2 |
9 | 13 | 582.96 | 38 | 13.47 | 1233 | 631 | 5.61 / 876.08 | 2 | 2 |
10 | 8 | -0.08 | 180 | 14.43 | 288 | 748 | 6.36 / 876.82 | 2 | 2 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 31 | 14.36 | 433 | 193 | 0.19 / 864.47 | 2 | 2 |
2 | 3 | 962.92 | -1 | 14.36 | 433 | 0 | 0.00 / 864.47 | 2 | 2 |
3 | 3 | 1046.40 | 1 | 11.88 | 1869 | 22 | 0.21 / 864.49 | 2 | 2 |
4 | 12 | 1131.88 | 12 | 7.94 | 1869 | 178 | 0.39 / 864.67 | 2 | 2 |
5 | 12 | 2000.12 | 65 | 5.87 | 3081 | 1176 | 1.57 / 865.84 | 2 | 2 |
6 | 12 | 2001.68 | 40 | 8.90 | 3149 | 1121 | 2.69 / 866.97 | 2 | 2 |
7 | 7 | 1994.56 | 30 | 10.42 | 3173 | 992 | 3.68 / 867.96 | 2 | 2 |
8 | 13 | 1496.60 | 38 | 12.57 | 2516 | 1202 | 4.88 / 869.16 | 2 | 2 |
9 | 13 | 449.08 | 38 | 13.61 | 1035 | 535 | 5.42 / 869.69 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.41 | 297 | 770 | 6.19 / 870.47 | 2 | 2 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 31 | 14.33 | 432 | 192 | 0.19 / 858.02 | 2 | 2 |
2 | 3 | 967.08 | -1 | 14.33 | 432 | 0 | 0.00 / 858.02 | 2 | 2 |
3 | 3 | 1057.56 | 1 | 11.28 | 1856 | 21 | 0.21 / 858.05 | 2 | 2 |
4 | 12 | 1151.80 | 12 | 4.82 | 2052 | 119 | 0.33 / 858.16 | 2 | 2 |
5 | 12 | 2006.60 | 65 | 4.98 | 2891 | 936 | 1.27 / 859.10 | 2 | 2 |
6 | 12 | 2010.04 | 40 | 8.72 | 3145 | 1097 | 2.36 / 860.20 | 2 | 2 |
7 | 7 | 2008.40 | 30 | 10.44 | 3166 | 992 | 3.36 / 861.19 | 2 | 2 |
8 | 13 | 1789.76 | 38 | 12.29 | 2907 | 1358 | 4.71 / 862.55 | 2 | 2 |
9 | 13 | 818.20 | 38 | 13.25 | 1569 | 790 | 5.50 / 863.34 | 2 | 2 |
10 | 13 | 31.60 | 38 | 14.37 | 336 | 183 | 5.69 / 863.52 | 2 | 2 |
11 | 8 | -0.12 | 180 | 14.44 | 291 | 756 | 6.44 / 864.28 | 2 | 2 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 31 | 14.38 | 424 | 189 | 0.19 / 852.30 | 2 | 2 |
2 | 3 | 957.16 | -1 | 14.38 | 424 | 0 | 0.00 / 852.30 | 2 | 2 |
3 | 3 | 1050.28 | 1 | 11.89 | 1877 | 22 | 0.21 / 852.33 | 2 | 2 |
4 | 12 | 1142.36 | 6 | 4.83 | 1980 | 57 | 0.27 / 852.38 | 2 | 2 |
5 | 12 | 2004.04 | 10 | 4.95 | 2501 | 124 | 0.39 / 852.51 | 2 | 2 |
6 | 7 | 2006.08 | 55 | 6.87 | 3084 | 1165 | 1.56 / 853.67 | 2 | 2 |
7 | 13 | 1906.84 | 38 | 12.09 | 3087 | 1418 | 2.98 / 855.09 | 2 | 2 |
8 | 13 | 1488.64 | 38 | 12.60 | 2505 | 1199 | 4.18 / 856.29 | 2 | 2 |
9 | 13 | 511.12 | 38 | 13.55 | 1130 | 582 | 4.76 / 856.87 | 2 | 2 |
10 | 13 | 22.44 | 38 | 14.37 | 333 | 182 | 4.94 / 857.05 | 2 | 2 |
11 | 8 | -0.28 | 180 | 14.41 | 300 | 778 | 5.72 / 857.83 | 2 | 3 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 31 | 14.30 | 407 | 180 | 0.18 / 846.26 | 2 | 2 |
2 | 12 | 1108.16 | 6 | 4.74 | 1569 | 45 | 0.23 / 846.31 | 2 | 2 |
3 | 12 | 2005.20 | 10 | 4.83 | 1918 | 93 | 0.32 / 846.40 | 2 | 2 |
4 | 7 | 2006.80 | 55 | 5.13 | 2750 | 776 | 1.09 / 847.18 | 2 | 2 |
5 | 13 | 2060.44 | 38 | 11.78 | 3266 | 1462 | 2.56 / 848.64 | 2 | 2 |
6 | 13 | 1877.88 | 38 | 12.17 | 3029 | 1401 | 3.96 / 850.04 | 2 | 2 |
7 | 13 | 1158.80 | 38 | 12.92 | 2055 | 1009 | 4.97 / 851.05 | 2 | 2 |
8 | 13 | 176.36 | 38 | 14.06 | 581 | 310 | 5.28 / 851.36 | 2 | 2 |
9 | 8 | -0.32 | 180 | 14.41 | 292 | 757 | 6.03 / 852.12 | 2 | 2 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 30 | 14.32 | 429 | 184 | 0.18 / 840.25 | 2 | 2 |
2 | 3 | 966.64 | -1 | 14.32 | 429 | 0 | 0.00 / 840.25 | 2 | 2 |
3 | 3 | 1054.72 | 1 | 11.78 | 1865 | 22 | 0.21 / 840.27 | 2 | 2 |
4 | 12 | 1143.80 | 6 | 4.71 | 1491 | 42 | 0.25 / 840.31 | 2 | 2 |
5 | 12 | 2002.80 | 10 | 4.80 | 1810 | 87 | 0.34 / 840.40 | 2 | 2 |
6 | 7 | 2005.04 | 55 | 5.06 | 2685 | 747 | 1.08 / 841.15 | 2 | 2 |
7 | 13 | 2076.72 | 38 | 11.60 | 3274 | 1443 | 2.53 / 842.59 | 2 | 2 |
8 | 13 | 1895.68 | 38 | 12.10 | 3071 | 1412 | 3.94 / 844.00 | 2 | 2 |
9 | 13 | 1193.16 | 38 | 12.91 | 2079 | 1020 | 4.96 / 845.02 | 2 | 2 |
10 | 13 | 191.32 | 38 | 14.06 | 592 | 316 | 5.27 / 845.34 | 2 | 2 |
11 | 8 | -0.20 | 180 | 14.42 | 287 | 745 | 6.02 / 846.08 | 2 | 2 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 30 | 14.39 | 397 | 171 | 0.17 / 836.82 | 2 | 2 |
2 | 3 | 968.60 | -1 | 14.39 | 397 | 0 | 0.00 / 836.82 | 2 | 2 |
3 | 3 | 1063.08 | 2 | 11.18 | 1871 | 42 | 0.21 / 836.86 | 2 | 2 |
4 | 12 | 1058.48 | 6 | 4.75 | 1649 | 47 | 0.26 / 836.91 | 2 | 2 |
5 | 12 | 1348.68 | 10 | 4.84 | 1980 | 96 | 0.36 / 837.01 | 2 | 2 |
6 | 7 | 1348.80 | 55 | 8.38 | 2205 | 1016 | 1.37 / 838.02 | 2 | 2 |
7 | 13 | 1133.64 | 38 | 12.86 | 2002 | 978 | 2.35 / 839.00 | 2 | 2 |
8 | 13 | 199.64 | 38 | 14.01 | 605 | 322 | 2.67 / 839.32 | 2 | 2 |
9 | 8 | -0.40 | 180 | 14.39 | 286 | 741 | 3.41 / 840.06 | 2 | 3 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 30 | 14.41 | 420 | 182 | 0.18 / 830.69 | 2 | 2 |
2 | 12 | 1110.28 | 6 | 4.75 | 1634 | 47 | 0.23 / 830.73 | 2 | 2 |
3 | 12 | 2005.04 | 10 | 4.85 | 2010 | 97 | 0.33 / 830.83 | 2 | 2 |
4 | 7 | 2007.12 | 55 | 5.21 | 2900 | 831 | 1.16 / 831.66 | 2 | 2 |
5 | 13 | 2081.08 | 38 | 11.90 | 3291 | 1488 | 2.64 / 833.15 | 2 | 2 |
6 | 13 | 1875.92 | 38 | 12.26 | 3041 | 1417 | 4.06 / 834.57 | 2 | 2 |
7 | 13 | 1153.44 | 38 | 12.98 | 2031 | 1002 | 5.06 / 835.57 | 2 | 2 |
8 | 13 | 175.52 | 38 | 14.08 | 601 | 322 | 5.38 / 835.89 | 2 | 2 |
9 | 8 | -0.32 | 180 | 14.44 | 292 | 759 | 6.14 / 836.65 | 2 | 4 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 30 | 14.43 | 412 | 178 | 0.18 / 824.64 | 2 | 2 |
2 | 3 | 964.24 | -1 | 14.43 | 412 | 0 | 0.00 / 824.64 | 2 | 2 |
3 | 3 | 1049.20 | 1 | 11.92 | 1852 | 22 | 0.20 / 824.67 | 2 | 2 |
4 | 12 | 1153.08 | 6 | 4.78 | 1766 | 51 | 0.25 / 824.72 | 2 | 2 |
5 | 12 | 2001.48 | 10 | 4.90 | 2248 | 110 | 0.36 / 824.83 | 2 | 2 |
6 | 7 | 2003.80 | 55 | 6.09 | 3148 | 1054 | 1.42 / 825.88 | 2 | 2 |
7 | 13 | 1984.72 | 38 | 12.07 | 3160 | 1449 | 2.87 / 827.33 | 2 | 2 |
8 | 13 | 1765.52 | 38 | 12.37 | 2887 | 1357 | 4.22 / 828.69 | 2 | 2 |
9 | 13 | 803.64 | 38 | 13.30 | 1546 | 781 | 5.00 / 829.47 | 2 | 2 |
10 | 13 | 129.08 | 38 | 14.18 | 516 | 278 | 5.28 / 829.75 | 2 | 2 |
11 | 8 | -0.28 | 180 | 14.43 | 292 | 758 | 6.04 / 830.51 | 2 | 2 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 30 | 14.43 | 404 | 175 | 0.17 / 818.96 | 2 | 2 |
2 | 3 | 952.12 | -1 | 14.43 | 404 | 0 | 0.00 / 818.96 | 2 | 2 |
3 | 3 | 1043.00 | 1 | 11.86 | 1856 | 22 | 0.20 / 818.98 | 2 | 2 |
4 | 12 | 1145.60 | 6 | 4.79 | 1790 | 51 | 0.25 / 819.03 | 2 | 2 |
5 | 12 | 2010.52 | 10 | 4.91 | 2278 | 112 | 0.36 / 819.14 | 2 | 2 |
6 | 7 | 2013.00 | 55 | 6.77 | 3056 | 1138 | 1.50 / 820.28 | 2 | 2 |
7 | 13 | 1922.40 | 38 | 12.13 | 3083 | 1421 | 2.92 / 821.70 | 2 | 2 |
8 | 13 | 1480.04 | 38 | 12.67 | 2479 | 1194 | 4.11 / 822.90 | 2 | 2 |
9 | 13 | 531.12 | 38 | 13.57 | 1147 | 591 | 4.70 / 823.49 | 2 | 2 |
10 | 13 | 51.16 | 38 | 14.33 | 376 | 205 | 4.91 / 823.69 | 2 | 2 |
11 | 8 | -0.36 | 180 | 14.42 | 298 | 773 | 5.68 / 824.47 | 2 | 5 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 30 | 14.42 | 415 | 180 | 0.18 / 813.18 | 2 | 2 |
2 | 3 | 963.20 | -1 | 14.42 | 415 | 0 | 0.00 / 813.18 | 2 | 2 |
3 | 3 | 1062.44 | 2 | 12.17 | 1898 | 46 | 0.23 / 813.22 | 2 | 2 |
4 | 12 | 1163.56 | 6 | 4.76 | 1661 | 47 | 0.27 / 813.27 | 2 | 2 |
5 | 12 | 2008.40 | 10 | 4.88 | 2157 | 105 | 0.38 / 813.37 | 2 | 2 |
6 | 7 | 2010.04 | 55 | 6.63 | 3063 | 1117 | 1.50 / 814.49 | 2 | 2 |
7 | 13 | 1917.28 | 38 | 12.12 | 3095 | 1425 | 2.92 / 815.92 | 2 | 2 |
8 | 13 | 1709.36 | 38 | 12.43 | 2818 | 1331 | 4.25 / 817.25 | 2 | 2 |
9 | 13 | 523.52 | 38 | 13.59 | 1137 | 587 | 4.84 / 817.84 | 2 | 2 |
10 | 13 | 55.80 | 38 | 14.35 | 367 | 200 | 5.04 / 818.04 | 2 | 2 |
11 | 8 | -0.36 | 180 | 14.44 | 288 | 749 | 5.79 / 818.78 | 2 | 3 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 31 | 14.46 | 410 | 184 | 0.18 / 807.59 | 2 | 2 |
2 | 3 | 945.84 | -1 | 14.46 | 410 | 0 | 0.00 / 807.59 | 2 | 2 |
3 | 3 | 1027.36 | 1 | 11.84 | 1840 | 22 | 0.21 / 807.61 | 2 | 2 |
4 | 12 | 1115.32 | 6 | 4.85 | 2057 | 60 | 0.27 / 807.67 | 2 | 2 |
5 | 12 | 2002.64 | 10 | 4.99 | 2706 | 135 | 0.40 / 807.81 | 2 | 2 |
6 | 7 | 2004.36 | 55 | 8.36 | 3086 | 1419 | 1.82 / 809.23 | 2 | 2 |
7 | 13 | 1849.04 | 38 | 12.21 | 3012 | 1398 | 3.22 / 810.63 | 2 | 2 |
8 | 13 | 1376.92 | 38 | 12.75 | 2360 | 1143 | 4.36 / 811.77 | 2 | 2 |
9 | 13 | 349.56 | 38 | 13.80 | 869 | 456 | 4.82 / 812.22 | 2 | 2 |
10 | 8 | -0.36 | 180 | 14.43 | 297 | 771 | 5.59 / 813.00 | 2 | 2 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 31 | 14.30 | 399 | 177 | 0.18 / 801.73 | 2 | 2 |
2 | 3 | 938.84 | -1 | 14.30 | 399 | 0 | 0.00 / 801.73 | 2 | 2 |
3 | 3 | 1032.16 | 1 | 7.75 | 1759 | 14 | 0.19 / 801.75 | 2 | 2 |
4 | 12 | 1157.60 | 6 | 4.63 | 1165 | 32 | 0.22 / 801.78 | 2 | 2 |
5 | 12 | 2005.52 | 10 | 4.71 | 1433 | 67 | 0.29 / 801.85 | 2 | 2 |
6 | 7 | 2005.52 | 55 | 4.97 | 2679 | 732 | 1.02 / 802.58 | 2 | 2 |
7 | 13 | 2002.48 | 38 | 11.86 | 3185 | 1435 | 2.46 / 804.02 | 2 | 2 |
8 | 13 | 1827.20 | 38 | 12.24 | 2958 | 1376 | 3.83 / 805.39 | 2 | 2 |
9 | 13 | 1096.28 | 38 | 13.03 | 1956 | 968 | 4.80 / 806.36 | 2 | 2 |
10 | 13 | 168.16 | 38 | 14.13 | 576 | 309 | 5.11 / 806.67 | 2 | 2 |
11 | 8 | -0.24 | 180 | 14.46 | 284 | 739 | 5.85 / 807.41 | 2 | 2 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 32 | 14.36 | 401 | 184 | 0.18 / 798.36 | 2 | 2 |
2 | 3 | 904.72 | -2 | 14.36 | 401 | 0 | 0.00 / 798.36 | 2 | 2 |
3 | 3 | 1088.00 | 2 | 11.29 | 1927 | 44 | 0.23 / 798.41 | 2 | 2 |
4 | 12 | 1055.92 | 6 | 4.65 | 1248 | 35 | 0.26 / 798.44 | 2 | 2 |
5 | 12 | 1375.20 | 10 | 4.72 | 1508 | 71 | 0.33 / 798.51 | 2 | 2 |
6 | 7 | 1374.52 | 55 | 7.95 | 2216 | 969 | 1.30 / 799.48 | 2 | 2 |
7 | 13 | 1160.84 | 38 | 12.82 | 2039 | 993 | 2.30 / 800.48 | 2 | 2 |
8 | 13 | 223.40 | 38 | 13.99 | 643 | 342 | 2.64 / 800.82 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.43 | 285 | 740 | 3.38 / 801.56 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 28 | 14.37 | 427 | 172 | 0.17 / 792.92 | 2 | 2 |
2 | 10 | 1014.00 | 4 | 12.53 | 1832 | 92 | 0.26 / 793.01 | 2 | 2 |
3 | 3 | 937.48 | -1 | 12.53 | 1832 | 0 | 0.09 / 793.01 | 2 | 2 |
4 | 3 | 1041.00 | 1 | 11.99 | 1868 | 22 | 0.29 / 793.04 | 2 | 2 |
5 | 12 | 1129.56 | 6 | 4.69 | 1398 | 39 | 0.33 / 793.08 | 2 | 2 |
6 | 12 | 1737.04 | 10 | 4.77 | 1681 | 80 | 0.41 / 793.16 | 2 | 2 |
7 | 7 | 1737.08 | 54 | 7.38 | 2724 | 1086 | 1.49 / 794.24 | 2 | 2 |
8 | 13 | 1655.84 | 38 | 12.21 | 2756 | 1279 | 2.77 / 795.52 | 2 | 2 |
9 | 13 | 1449.76 | 38 | 12.56 | 2461 | 1175 | 3.94 / 796.69 | 2 | 2 |
10 | 13 | 422.04 | 38 | 13.66 | 1002 | 520 | 4.46 / 797.21 | 2 | 2 |
11 | 13 | 29.16 | 38 | 14.37 | 342 | 187 | 4.65 / 797.40 | 2 | 2 |
12 | 8 | -0.24 | 180 | 14.42 | 300 | 779 | 5.43 / 798.18 | 2 | 7 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 30 | 14.46 | 406 | 176 | 0.18 / 789.31 | 2 | 2 |
2 | 3 | 972.80 | -1 | 14.46 | 406 | 0 | 0.00 / 789.31 | 2 | 2 |
3 | 12 | 1084.88 | 6 | 4.76 | 1678 | 48 | 0.22 / 789.35 | 2 | 2 |
4 | 12 | 1409.68 | 10 | 5.42 | 2098 | 114 | 0.34 / 789.47 | 2 | 2 |
5 | 7 | 1409.60 | 54 | 9.62 | 2316 | 1203 | 1.54 / 790.67 | 2 | 2 |
6 | 13 | 1196.96 | 38 | 12.73 | 2094 | 1013 | 2.55 / 791.68 | 2 | 2 |
7 | 13 | 179.08 | 38 | 14.06 | 583 | 311 | 2.87 / 791.99 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.41 | 291 | 755 | 3.62 / 792.75 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 30 | 14.42 | 399 | 173 | 0.17 / 783.81 | 2 | 2 |
2 | 12 | 1093.16 | 6 | 4.79 | 1771 | 51 | 0.22 / 783.86 | 2 | 2 |
3 | 12 | 2005.48 | 10 | 4.93 | 2375 | 117 | 0.34 / 783.98 | 2 | 2 |
4 | 7 | 2007.56 | 55 | 8.25 | 3088 | 1401 | 1.74 / 785.38 | 2 | 2 |
5 | 13 | 1861.80 | 38 | 12.06 | 3004 | 1377 | 3.12 / 786.76 | 2 | 2 |
6 | 13 | 1387.68 | 38 | 12.65 | 2353 | 1131 | 4.25 / 787.89 | 2 | 2 |
7 | 13 | 388.72 | 38 | 13.70 | 940 | 489 | 4.74 / 788.38 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.42 | 290 | 753 | 5.49 / 789.13 | 2 | 2 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 30 | 14.39 | 402 | 174 | 0.17 / 778.50 | 2 | 2 |
2 | 12 | 1102.64 | 6 | 4.85 | 2059 | 60 | 0.23 / 778.56 | 2 | 2 |
3 | 12 | 2000.88 | 10 | 5.01 | 2773 | 139 | 0.37 / 778.70 | 2 | 2 |
4 | 7 | 2002.64 | 55 | 9.00 | 3114 | 1541 | 1.91 / 780.24 | 2 | 2 |
5 | 13 | 1823.48 | 38 | 12.03 | 2947 | 1347 | 3.26 / 781.58 | 2 | 2 |
6 | 13 | 1117.40 | 38 | 12.84 | 2013 | 982 | 4.24 / 782.57 | 2 | 2 |
7 | 13 | 191.76 | 38 | 14.06 | 596 | 318 | 4.56 / 782.89 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.42 | 290 | 753 | 5.31 / 783.64 | 2 | 2 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 29 | 14.37 | 403 | 168 | 0.17 / 773.13 | 2 | 2 |
2 | 12 | 1109.80 | 6 | 7.03 | 1842 | 78 | 0.25 / 773.21 | 2 | 2 |
3 | 12 | 2008.40 | 10 | 5.07 | 3047 | 154 | 0.40 / 773.36 | 2 | 2 |
4 | 7 | 2011.00 | 55 | 9.57 | 3158 | 1662 | 2.06 / 775.02 | 2 | 2 |
5 | 13 | 1836.72 | 38 | 11.99 | 2977 | 1356 | 3.42 / 776.38 | 2 | 2 |
6 | 13 | 1058.40 | 38 | 12.92 | 1899 | 932 | 4.35 / 777.31 | 2 | 2 |
7 | 13 | 141.84 | 38 | 14.16 | 510 | 274 | 4.63 / 777.59 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.43 | 284 | 738 | 5.36 / 778.32 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 29 | 14.36 | 422 | 176 | 0.18 / 767.72 | 2 | 2 |
2 | 12 | 1147.76 | 6 | 6.36 | 1894 | 72 | 0.25 / 767.79 | 2 | 2 |
3 | 12 | 2002.68 | 10 | 5.04 | 2924 | 147 | 0.40 / 767.94 | 2 | 2 |
4 | 7 | 2004.88 | 55 | 9.55 | 3128 | 1643 | 2.04 / 769.58 | 2 | 2 |
5 | 13 | 1827.28 | 38 | 11.89 | 2948 | 1332 | 3.37 / 770.91 | 2 | 2 |
6 | 13 | 1119.28 | 38 | 12.81 | 1987 | 967 | 4.34 / 771.88 | 2 | 2 |
7 | 13 | 174.32 | 38 | 14.04 | 596 | 318 | 4.66 / 772.20 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.39 | 294 | 762 | 5.42 / 772.96 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 30 | 14.39 | 404 | 174 | 0.17 / 764.30 | 2 | 2 |
2 | 3 | 968.04 | -1 | 14.39 | 404 | 0 | 0.00 / 764.30 | 2 | 2 |
3 | 12 | 1076.04 | 6 | 8.13 | 1816 | 89 | 0.26 / 764.39 | 2 | 2 |
4 | 12 | 1364.52 | 10 | 8.28 | 2105 | 174 | 0.44 / 764.57 | 2 | 2 |
5 | 7 | 1363.44 | 55 | 10.55 | 2269 | 1317 | 1.75 / 765.88 | 2 | 2 |
6 | 13 | 687.40 | 38 | 13.22 | 1381 | 694 | 2.45 / 766.58 | 2 | 2 |
7 | 13 | 46.20 | 38 | 14.31 | 368 | 200 | 2.65 / 766.78 | 2 | 2 |
8 | 8 | -0.08 | 180 | 14.38 | 296 | 766 | 3.41 / 767.54 | 2 | 5 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 30 | 14.39 | 415 | 179 | 0.18 / 759.03 | 2 | 2 |
2 | 3 | 960.00 | -1 | 14.39 | 415 | 0 | 0.00 / 759.03 | 2 | 2 |
3 | 3 | 1052.40 | 1 | 11.68 | 1857 | 22 | 0.20 / 759.05 | 2 | 2 |
4 | 12 | 1147.44 | 6 | 7.48 | 1885 | 85 | 0.29 / 759.13 | 2 | 2 |
5 | 12 | 2005.88 | 10 | 6.18 | 2939 | 182 | 0.47 / 759.32 | 2 | 2 |
6 | 7 | 2007.12 | 55 | 9.70 | 3125 | 1667 | 2.13 / 760.98 | 2 | 2 |
7 | 13 | 1802.96 | 38 | 12.03 | 2927 | 1338 | 3.47 / 762.32 | 2 | 2 |
8 | 13 | 878.88 | 38 | 13.12 | 1647 | 821 | 4.29 / 763.14 | 2 | 2 |
9 | 13 | 98.44 | 38 | 14.24 | 444 | 240 | 4.53 / 763.38 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.42 | 288 | 748 | 5.28 / 764.13 | 2 | 3 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 30 | 14.40 | 424 | 183 | 0.18 / 753.84 | 2 | 2 |
2 | 3 | 950.84 | -1 | 14.40 | 424 | 0 | 0.00 / 753.84 | 2 | 2 |
3 | 3 | 1044.96 | 1 | 12.19 | 1834 | 22 | 0.21 / 753.86 | 2 | 2 |
4 | 12 | 1148.24 | 6 | 9.39 | 1941 | 109 | 0.31 / 753.97 | 2 | 2 |
5 | 12 | 2004.36 | 10 | 7.38 | 2936 | 217 | 0.53 / 754.18 | 2 | 2 |
6 | 7 | 2005.20 | 55 | 9.97 | 3152 | 1728 | 2.26 / 755.91 | 2 | 2 |
7 | 13 | 1608.52 | 38 | 12.28 | 2679 | 1250 | 3.51 / 757.16 | 2 | 2 |
8 | 13 | 676.92 | 38 | 13.34 | 1367 | 693 | 4.20 / 757.86 | 2 | 2 |
9 | 13 | 37.64 | 38 | 14.35 | 368 | 201 | 4.40 / 758.06 | 2 | 2 |
10 | 8 | -0.16 | 180 | 14.39 | 306 | 793 | 5.20 / 758.85 | 2 | 4 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 30 | 14.38 | 435 | 188 | 0.19 / 748.43 | 2 | 2 |
2 | 3 | 959.16 | -1 | 14.38 | 435 | 0 | 0.00 / 748.43 | 2 | 2 |
3 | 3 | 1054.56 | 1 | 12.21 | 1864 | 23 | 0.21 / 748.45 | 2 | 2 |
4 | 12 | 1142.08 | 6 | 9.54 | 1927 | 110 | 0.32 / 748.56 | 2 | 2 |
5 | 12 | 2006.28 | 10 | 7.39 | 2894 | 214 | 0.53 / 748.78 | 2 | 2 |
6 | 7 | 2007.48 | 55 | 10.01 | 3175 | 1748 | 2.28 / 750.53 | 2 | 2 |
7 | 13 | 1804.28 | 38 | 12.08 | 2925 | 1343 | 3.63 / 751.87 | 2 | 2 |
8 | 13 | 839.00 | 38 | 13.14 | 1621 | 809 | 4.43 / 752.68 | 2 | 2 |
9 | 13 | 82.88 | 38 | 14.29 | 417 | 226 | 4.66 / 752.90 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.42 | 288 | 748 | 5.41 / 753.65 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 14.40 | 425 | 184 | 0.18 / 743.01 | 2 | 2 |
2 | 3 | 964.16 | -1 | 14.40 | 425 | 0 | 0.00 / 743.01 | 2 | 2 |
3 | 3 | 1068.60 | 2 | 12.06 | 1897 | 46 | 0.23 / 743.06 | 2 | 2 |
4 | 12 | 1133.40 | 6 | 9.68 | 1904 | 111 | 0.34 / 743.17 | 2 | 2 |
5 | 12 | 2005.36 | 10 | 7.41 | 2927 | 217 | 0.56 / 743.38 | 2 | 2 |
6 | 7 | 2006.56 | 54 | 10.06 | 3151 | 1712 | 2.27 / 745.10 | 2 | 2 |
7 | 13 | 1803.96 | 38 | 12.05 | 2938 | 1345 | 3.61 / 746.44 | 2 | 2 |
8 | 13 | 844.28 | 38 | 13.15 | 1620 | 810 | 4.42 / 747.25 | 2 | 2 |
9 | 13 | 77.00 | 38 | 14.28 | 425 | 231 | 4.65 / 747.48 | 2 | 2 |
10 | 8 | -0.32 | 180 | 14.41 | 294 | 763 | 5.42 / 748.24 | 2 | 2 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 31 | 14.42 | 414 | 185 | 0.19 / 737.59 | 2 | 2 |
2 | 3 | 923.80 | -1 | 14.42 | 414 | 0 | 0.00 / 737.59 | 2 | 2 |
3 | 3 | 1022.92 | 1 | 11.82 | 1857 | 22 | 0.21 / 737.61 | 2 | 2 |
4 | 12 | 1118.20 | 6 | 9.54 | 1881 | 108 | 0.31 / 737.72 | 2 | 2 |
5 | 12 | 2006.88 | 10 | 7.24 | 2877 | 208 | 0.52 / 737.93 | 2 | 2 |
6 | 7 | 2008.12 | 55 | 10.10 | 3140 | 1744 | 2.27 / 739.67 | 2 | 2 |
7 | 13 | 1789.80 | 38 | 12.11 | 2913 | 1341 | 3.61 / 741.01 | 2 | 2 |
8 | 13 | 820.48 | 38 | 13.17 | 1597 | 799 | 4.41 / 741.81 | 2 | 2 |
9 | 13 | 71.20 | 38 | 14.29 | 422 | 229 | 4.64 / 742.04 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.41 | 303 | 786 | 5.42 / 742.83 | 2 | 2 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 30 | 14.37 | 448 | 193 | 0.19 / 732.03 | 2 | 2 |
2 | 3 | 963.40 | -1 | 14.37 | 448 | 0 | 0.00 / 732.03 | 2 | 2 |
3 | 3 | 1070.76 | 2 | 12.10 | 1914 | 46 | 0.24 / 732.08 | 2 | 2 |
4 | 12 | 1140.24 | 6 | 10.29 | 1924 | 119 | 0.36 / 732.19 | 2 | 2 |
5 | 12 | 2002.48 | 10 | 7.46 | 2824 | 211 | 0.57 / 732.40 | 2 | 2 |
6 | 7 | 2003.40 | 54 | 10.08 | 3151 | 1715 | 2.28 / 734.12 | 2 | 2 |
7 | 13 | 1794.48 | 38 | 12.08 | 2911 | 1336 | 3.62 / 735.46 | 2 | 2 |
8 | 13 | 1051.76 | 38 | 12.94 | 1893 | 931 | 4.55 / 736.39 | 2 | 2 |
9 | 13 | 125.48 | 38 | 14.18 | 499 | 269 | 4.82 / 736.66 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.40 | 289 | 749 | 5.57 / 737.40 | 2 | 3 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 31 | 14.38 | 425 | 189 | 0.19 / 726.60 | 2 | 2 |
2 | 3 | 937.76 | -1 | 14.38 | 425 | 0 | 0.00 / 726.60 | 2 | 2 |
3 | 3 | 1020.40 | 1 | 11.59 | 1835 | 21 | 0.21 / 726.62 | 2 | 2 |
4 | 12 | 1140.44 | 6 | 11.00 | 1953 | 129 | 0.34 / 726.75 | 2 | 2 |
5 | 12 | 2004.72 | 10 | 7.34 | 2809 | 206 | 0.55 / 726.95 | 2 | 2 |
6 | 7 | 2005.80 | 55 | 10.06 | 3145 | 1740 | 2.29 / 728.69 | 2 | 2 |
7 | 13 | 1785.28 | 38 | 12.11 | 2893 | 1331 | 3.62 / 730.02 | 2 | 2 |
8 | 13 | 807.52 | 38 | 13.19 | 1564 | 784 | 4.40 / 730.81 | 2 | 2 |
9 | 13 | 65.36 | 38 | 14.29 | 415 | 225 | 4.63 / 731.03 | 2 | 2 |
10 | 8 | 0.20 | 180 | 14.37 | 310 | 802 | 5.43 / 731.84 | 2 | 2 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 31 | 14.31 | 414 | 184 | 0.18 / 721.18 | 2 | 2 |
2 | 3 | 959.32 | -1 | 14.31 | 414 | 0 | 0.00 / 721.18 | 2 | 2 |
3 | 3 | 1059.60 | 2 | 11.44 | 1886 | 43 | 0.23 / 721.22 | 2 | 2 |
4 | 12 | 1155.88 | 6 | 8.00 | 1925 | 92 | 0.32 / 721.31 | 2 | 2 |
5 | 12 | 2001.64 | 10 | 7.15 | 2885 | 206 | 0.53 / 721.52 | 2 | 2 |
6 | 7 | 2002.72 | 55 | 9.76 | 3132 | 1681 | 2.21 / 723.20 | 2 | 2 |
7 | 13 | 1794.32 | 38 | 12.02 | 2938 | 1342 | 3.55 / 724.54 | 2 | 2 |
8 | 13 | 863.48 | 38 | 13.13 | 1629 | 813 | 4.36 / 725.35 | 2 | 2 |
9 | 13 | 159.28 | 38 | 14.11 | 552 | 296 | 4.66 / 725.65 | 2 | 2 |
10 | 8 | -0.32 | 180 | 14.38 | 293 | 758 | 5.42 / 726.41 | 2 | 2 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 30 | 14.27 | 420 | 180 | 0.18 / 715.85 | 2 | 2 |
2 | 3 | 961.12 | -1 | 14.27 | 420 | 0 | 0.00 / 715.85 | 2 | 2 |
3 | 3 | 1059.44 | 2 | 11.51 | 1874 | 43 | 0.22 / 715.89 | 2 | 2 |
4 | 12 | 1172.36 | 6 | 7.83 | 1925 | 90 | 0.31 / 715.98 | 2 | 2 |
5 | 12 | 2002.92 | 10 | 6.38 | 3046 | 194 | 0.51 / 716.18 | 2 | 2 |
6 | 7 | 2003.56 | 55 | 9.93 | 3135 | 1712 | 2.22 / 717.89 | 2 | 2 |
7 | 13 | 1781.48 | 38 | 12.12 | 2887 | 1330 | 3.55 / 719.22 | 2 | 2 |
8 | 13 | 831.04 | 38 | 13.16 | 1591 | 796 | 4.35 / 720.01 | 2 | 2 |
9 | 13 | 72.20 | 38 | 14.32 | 406 | 221 | 4.57 / 720.23 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.42 | 292 | 758 | 5.32 / 720.99 | 2 | 3 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 30 | 14.34 | 403 | 173 | 0.17 / 710.38 | 2 | 2 |
2 | 3 | 961.28 | -1 | 14.34 | 403 | 0 | 0.00 / 710.38 | 2 | 2 |
3 | 3 | 1052.16 | 1 | 11.41 | 1886 | 22 | 0.19 / 710.40 | 2 | 2 |
4 | 12 | 1152.96 | 6 | 9.74 | 1944 | 114 | 0.31 / 710.51 | 2 | 2 |
5 | 12 | 2001.84 | 10 | 6.36 | 2932 | 186 | 0.49 / 710.70 | 2 | 2 |
6 | 7 | 2003.56 | 55 | 10.03 | 3149 | 1737 | 2.23 / 712.44 | 2 | 2 |
7 | 13 | 1812.84 | 38 | 12.03 | 2956 | 1351 | 3.58 / 713.79 | 2 | 2 |
8 | 13 | 868.68 | 38 | 13.13 | 1634 | 815 | 4.40 / 714.60 | 2 | 2 |
9 | 13 | 152.40 | 38 | 14.11 | 555 | 298 | 4.70 / 714.90 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.38 | 296 | 766 | 5.46 / 715.67 | 2 | 2 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 30 | 14.32 | 400 | 172 | 0.17 / 705.00 | 2 | 2 |
2 | 3 | 963.72 | -1 | 14.32 | 400 | 0 | 0.00 / 705.00 | 2 | 2 |
3 | 3 | 1066.04 | 2 | 11.77 | 1884 | 44 | 0.22 / 705.04 | 2 | 2 |
4 | 12 | 1141.96 | 6 | 8.92 | 1897 | 102 | 0.32 / 705.14 | 2 | 2 |
5 | 12 | 2002.20 | 10 | 7.23 | 2844 | 206 | 0.52 / 705.35 | 2 | 2 |
6 | 7 | 2003.68 | 55 | 9.83 | 3145 | 1700 | 2.22 / 707.05 | 2 | 2 |
7 | 13 | 1799.20 | 38 | 12.05 | 2924 | 1339 | 3.56 / 708.39 | 2 | 2 |
8 | 13 | 820.80 | 38 | 13.16 | 1572 | 786 | 4.35 / 709.17 | 2 | 2 |
9 | 13 | 144.72 | 38 | 14.16 | 520 | 280 | 4.63 / 709.45 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.40 | 290 | 752 | 5.38 / 710.21 | 2 | 3 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 30 | 14.38 | 438 | 189 | 0.19 / 699.76 | 2 | 2 |
2 | 3 | 942.20 | -1 | 14.38 | 438 | 0 | 0.00 / 699.76 | 2 | 2 |
3 | 3 | 1039.52 | 1 | 11.91 | 1856 | 22 | 0.21 / 699.79 | 2 | 2 |
4 | 12 | 1134.80 | 6 | 11.40 | 1948 | 133 | 0.34 / 699.92 | 2 | 2 |
5 | 12 | 2002.24 | 10 | 7.88 | 3037 | 239 | 0.58 / 700.16 | 2 | 2 |
6 | 7 | 2002.68 | 55 | 10.21 | 3127 | 1756 | 2.34 / 701.91 | 2 | 2 |
7 | 13 | 1578.60 | 38 | 12.32 | 2629 | 1231 | 3.57 / 703.15 | 2 | 2 |
8 | 13 | 643.68 | 38 | 13.34 | 1338 | 678 | 4.25 / 703.82 | 2 | 2 |
9 | 13 | 74.68 | 38 | 14.28 | 420 | 228 | 4.48 / 704.05 | 2 | 2 |
10 | 8 | -0.12 | 180 | 14.37 | 299 | 773 | 5.25 / 704.82 | 2 | 2 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 31 | 14.36 | 437 | 195 | 0.19 / 694.38 | 2 | 2 |
2 | 3 | 937.32 | -1 | 14.36 | 437 | 0 | 0.00 / 694.38 | 2 | 2 |
3 | 3 | 1031.68 | 1 | 11.73 | 1848 | 22 | 0.22 / 694.40 | 2 | 2 |
4 | 12 | 1134.08 | 6 | 9.56 | 1900 | 109 | 0.33 / 694.51 | 2 | 2 |
5 | 12 | 2004.92 | 10 | 7.39 | 2832 | 209 | 0.53 / 694.72 | 2 | 2 |
6 | 7 | 2006.12 | 55 | 9.97 | 3155 | 1730 | 2.26 / 696.45 | 2 | 2 |
7 | 13 | 1785.88 | 38 | 12.01 | 2902 | 1324 | 3.59 / 697.78 | 2 | 2 |
8 | 13 | 802.04 | 38 | 13.14 | 1558 | 778 | 4.37 / 698.55 | 2 | 2 |
9 | 13 | 126.72 | 38 | 14.17 | 493 | 265 | 4.63 / 698.82 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.38 | 292 | 756 | 5.39 / 699.57 | 2 | 3 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 30 | 14.26 | 409 | 175 | 0.17 / 690.93 | 2 | 2 |
2 | 3 | 973.12 | -1 | 14.26 | 409 | 0 | 0.00 / 690.93 | 2 | 2 |
3 | 3 | 1082.80 | 2 | 11.76 | 1909 | 45 | 0.22 / 690.98 | 2 | 2 |
4 | 12 | 1050.72 | 6 | 10.76 | 1835 | 118 | 0.34 / 691.09 | 2 | 2 |
5 | 12 | 1312.20 | 10 | 7.77 | 2104 | 163 | 0.50 / 691.26 | 2 | 2 |
6 | 7 | 1311.56 | 55 | 11.13 | 2229 | 1364 | 1.87 / 692.62 | 2 | 2 |
7 | 13 | 610.00 | 38 | 13.31 | 1263 | 639 | 2.51 / 693.26 | 2 | 2 |
8 | 13 | 13.76 | 38 | 14.40 | 306 | 167 | 2.67 / 693.43 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.34 | 294 | 759 | 3.43 / 694.19 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 30 | 14.38 | 428 | 185 | 0.18 / 685.72 | 2 | 2 |
2 | 3 | 973.24 | -1 | 14.38 | 428 | 0 | 0.00 / 685.72 | 2 | 2 |
3 | 3 | 1072.56 | 2 | 12.02 | 1928 | 46 | 0.23 / 685.76 | 2 | 2 |
4 | 12 | 1167.00 | 6 | 11.38 | 2003 | 137 | 0.37 / 685.90 | 2 | 2 |
5 | 12 | 2001.96 | 10 | 9.00 | 3120 | 281 | 0.65 / 686.18 | 2 | 2 |
6 | 7 | 2002.08 | 54 | 10.22 | 3124 | 1724 | 2.37 / 687.91 | 2 | 2 |
7 | 13 | 1559.96 | 38 | 12.28 | 2596 | 1211 | 3.58 / 689.12 | 2 | 2 |
8 | 13 | 624.88 | 38 | 13.36 | 1290 | 655 | 4.24 / 689.77 | 2 | 2 |
9 | 13 | 71.72 | 38 | 14.27 | 417 | 226 | 4.47 / 690.00 | 2 | 2 |
10 | 8 | -0.20 | 180 | 14.37 | 293 | 758 | 5.22 / 690.76 | 2 | 3 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 30 | 14.34 | 456 | 196 | 0.20 / 680.53 | 2 | 2 |
2 | 12 | 1104.52 | 6 | 11.59 | 1929 | 134 | 0.33 / 680.66 | 2 | 2 |
3 | 12 | 2002.24 | 10 | 8.84 | 3052 | 270 | 0.60 / 680.93 | 2 | 2 |
4 | 7 | 2002.48 | 55 | 10.19 | 3140 | 1760 | 2.36 / 682.69 | 2 | 2 |
5 | 13 | 1583.36 | 38 | 12.28 | 2613 | 1219 | 3.58 / 683.91 | 2 | 2 |
6 | 13 | 609.72 | 38 | 13.36 | 1273 | 646 | 4.23 / 684.56 | 2 | 2 |
7 | 13 | 65.96 | 38 | 14.29 | 400 | 217 | 4.44 / 684.77 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.36 | 294 | 760 | 5.20 / 685.53 | 2 | 3 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 30 | 14.41 | 409 | 177 | 0.18 / 675.24 | 2 | 2 |
2 | 3 | 958.64 | -1 | 14.41 | 409 | 0 | 0.00 / 675.24 | 2 | 2 |
3 | 3 | 1046.68 | 1 | 11.82 | 1880 | 22 | 0.20 / 675.26 | 2 | 2 |
4 | 12 | 1148.76 | 6 | 11.60 | 1981 | 138 | 0.34 / 675.40 | 2 | 2 |
5 | 12 | 2002.00 | 10 | 8.98 | 3081 | 277 | 0.61 / 675.68 | 2 | 2 |
6 | 7 | 2002.36 | 55 | 10.35 | 3129 | 1781 | 2.39 / 677.46 | 2 | 2 |
7 | 13 | 1553.68 | 38 | 12.28 | 2605 | 1216 | 3.61 / 678.67 | 2 | 2 |
8 | 13 | 591.48 | 38 | 13.39 | 1252 | 637 | 4.25 / 679.31 | 2 | 2 |
9 | 13 | 62.12 | 38 | 14.28 | 407 | 221 | 4.47 / 679.53 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.34 | 309 | 798 | 5.27 / 680.33 | 2 | 3 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 30 | 14.29 | 413 | 177 | 0.18 / 669.86 | 2 | 2 |
2 | 12 | 1119.48 | 6 | 10.33 | 1920 | 119 | 0.30 / 669.98 | 2 | 2 |
3 | 12 | 2001.68 | 10 | 7.66 | 2817 | 216 | 0.51 / 670.20 | 2 | 2 |
4 | 7 | 2002.76 | 54 | 10.42 | 3147 | 1771 | 2.28 / 671.97 | 2 | 2 |
5 | 13 | 1783.36 | 38 | 12.01 | 2902 | 1324 | 3.61 / 673.29 | 2 | 2 |
6 | 13 | 811.00 | 38 | 13.15 | 1559 | 779 | 4.39 / 674.07 | 2 | 2 |
7 | 13 | 60.40 | 38 | 14.32 | 395 | 215 | 4.60 / 674.29 | 2 | 2 |
8 | 8 | -0.12 | 180 | 14.37 | 301 | 779 | 5.38 / 675.06 | 2 | 2 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 29 | 14.28 | 411 | 170 | 0.17 / 664.46 | 2 | 2 |
2 | 12 | 1127.44 | 6 | 11.61 | 1951 | 136 | 0.31 / 664.60 | 2 | 2 |
3 | 12 | 2001.68 | 10 | 7.96 | 2932 | 233 | 0.54 / 664.83 | 2 | 2 |
4 | 7 | 2002.52 | 54 | 10.45 | 3140 | 1772 | 2.31 / 666.60 | 2 | 2 |
5 | 13 | 1814.76 | 38 | 11.99 | 2933 | 1336 | 3.65 / 667.94 | 2 | 2 |
6 | 13 | 796.72 | 38 | 13.15 | 1534 | 767 | 4.41 / 668.71 | 2 | 2 |
7 | 13 | 64.32 | 38 | 14.31 | 397 | 216 | 4.63 / 668.92 | 2 | 2 |
8 | 8 | -0.28 | 180 | 14.37 | 295 | 763 | 5.39 / 669.68 | 2 | 2 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 29 | 14.33 | 444 | 185 | 0.18 / 659.29 | 2 | 2 |
2 | 12 | 1117.96 | 6 | 11.53 | 1943 | 134 | 0.32 / 659.42 | 2 | 2 |
3 | 12 | 2005.00 | 10 | 8.67 | 2964 | 257 | 0.58 / 659.68 | 2 | 2 |
4 | 7 | 2005.60 | 55 | 10.40 | 3158 | 1806 | 2.38 / 661.48 | 2 | 2 |
5 | 13 | 1578.56 | 38 | 12.20 | 2620 | 1215 | 3.60 / 662.70 | 2 | 2 |
6 | 13 | 614.96 | 38 | 13.34 | 1284 | 651 | 4.25 / 663.35 | 2 | 2 |
7 | 13 | 37.68 | 38 | 14.37 | 346 | 189 | 4.44 / 663.54 | 2 | 2 |
8 | 8 | 0.04 | 180 | 14.39 | 291 | 754 | 5.19 / 664.29 | 2 | 2 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 31 | 14.42 | 414 | 185 | 0.19 / 655.75 | 2 | 2 |
2 | 3 | 861.08 | -3 | 14.42 | 414 | 0 | 0.00 / 655.75 | 2 | 2 |
3 | 3 | 1096.40 | 2 | 12.22 | 1963 | 48 | 0.23 / 655.79 | 2 | 2 |
4 | 12 | 1067.00 | 6 | 11.72 | 1901 | 134 | 0.37 / 655.93 | 2 | 2 |
5 | 12 | 1269.36 | 10 | 10.37 | 2154 | 223 | 0.59 / 656.15 | 2 | 2 |
6 | 7 | 1268.64 | 55 | 11.43 | 2170 | 1364 | 1.95 / 657.52 | 2 | 2 |
7 | 13 | 538.60 | 38 | 13.35 | 1184 | 601 | 2.55 / 658.12 | 2 | 2 |
8 | 13 | 46.00 | 38 | 14.30 | 374 | 203 | 2.76 / 658.32 | 2 | 2 |
9 | 8 | -0.36 | 180 | 14.33 | 303 | 782 | 3.54 / 659.10 | 2 | 10 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 30 | 14.32 | 404 | 174 | 0.17 / 650.47 | 2 | 2 |
2 | 3 | 964.68 | -1 | 14.32 | 404 | 0 | 0.00 / 650.47 | 2 | 2 |
3 | 3 | 1081.44 | 2 | 11.91 | 1917 | 46 | 0.22 / 650.51 | 2 | 2 |
4 | 12 | 1174.12 | 6 | 10.80 | 1988 | 129 | 0.35 / 650.64 | 2 | 2 |
5 | 12 | 2006.24 | 10 | 8.31 | 2774 | 231 | 0.58 / 650.87 | 2 | 2 |
6 | 7 | 2007.12 | 55 | 10.53 | 3156 | 1828 | 2.41 / 652.70 | 2 | 2 |
7 | 13 | 1582.72 | 38 | 12.23 | 2662 | 1237 | 3.64 / 653.94 | 2 | 2 |
8 | 13 | 597.84 | 38 | 13.38 | 1274 | 648 | 4.29 / 654.58 | 2 | 2 |
9 | 13 | 68.20 | 38 | 14.31 | 401 | 218 | 4.51 / 654.80 | 2 | 2 |
10 | 8 | -0.20 | 180 | 14.38 | 293 | 758 | 5.27 / 655.56 | 2 | 3 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 30 | 14.38 | 402 | 173 | 0.17 / 645.19 | 2 | 2 |
2 | 3 | 953.72 | -1 | 14.38 | 402 | 0 | 0.00 / 645.19 | 2 | 2 |
3 | 3 | 1059.40 | 2 | 11.82 | 1905 | 45 | 0.22 / 645.23 | 2 | 2 |
4 | 12 | 1142.72 | 6 | 11.73 | 2013 | 142 | 0.36 / 645.38 | 2 | 2 |
5 | 12 | 2001.36 | 10 | 9.39 | 3154 | 296 | 0.66 / 645.67 | 2 | 2 |
6 | 7 | 2001.60 | 55 | 10.47 | 3156 | 1817 | 2.47 / 647.49 | 2 | 2 |
7 | 13 | 1555.08 | 38 | 12.24 | 2621 | 1219 | 3.69 / 648.71 | 2 | 2 |
8 | 13 | 594.12 | 38 | 13.38 | 1249 | 635 | 4.33 / 649.34 | 2 | 2 |
9 | 13 | 29.24 | 38 | 14.37 | 342 | 187 | 4.51 / 649.53 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.37 | 295 | 763 | 5.28 / 650.29 | 2 | 4 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 30 | 14.43 | 416 | 180 | 0.18 / 639.98 | 2 | 2 |
2 | 3 | 962.28 | -1 | 14.43 | 416 | 0 | 0.00 / 639.98 | 2 | 2 |
3 | 3 | 1052.60 | 1 | 12.05 | 1896 | 23 | 0.20 / 640.01 | 2 | 2 |
4 | 12 | 1143.64 | 6 | 11.66 | 2001 | 140 | 0.34 / 640.15 | 2 | 2 |
5 | 12 | 2002.52 | 10 | 10.38 | 3108 | 323 | 0.67 / 640.47 | 2 | 2 |
6 | 7 | 2002.32 | 55 | 10.41 | 3171 | 1816 | 2.48 / 642.28 | 2 | 2 |
7 | 13 | 1552.76 | 38 | 12.25 | 2604 | 1212 | 3.69 / 643.50 | 2 | 2 |
8 | 13 | 535.44 | 38 | 13.44 | 1164 | 594 | 4.29 / 644.09 | 2 | 2 |
9 | 13 | 10.00 | 38 | 14.43 | 303 | 166 | 4.45 / 644.26 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.35 | 294 | 759 | 5.21 / 645.02 | 2 | 4 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 30 | 14.43 | 412 | 178 | 0.18 / 634.74 | 2 | 2 |
2 | 3 | 946.28 | -1 | 14.43 | 412 | 0 | 0.00 / 634.74 | 2 | 2 |
3 | 3 | 1040.80 | 1 | 11.28 | 1872 | 21 | 0.20 / 634.76 | 2 | 2 |
4 | 12 | 1151.88 | 6 | 11.80 | 1987 | 141 | 0.34 / 634.90 | 2 | 2 |
5 | 12 | 2000.96 | 10 | 9.30 | 3154 | 293 | 0.63 / 635.19 | 2 | 2 |
6 | 7 | 2000.56 | 55 | 10.41 | 3147 | 1802 | 2.44 / 637.00 | 2 | 2 |
7 | 13 | 1545.60 | 38 | 12.28 | 2569 | 1199 | 3.63 / 638.19 | 2 | 2 |
8 | 13 | 573.08 | 38 | 13.39 | 1240 | 631 | 4.27 / 638.83 | 2 | 2 |
9 | 13 | 58.72 | 38 | 14.31 | 389 | 212 | 4.48 / 639.04 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.36 | 296 | 765 | 5.24 / 639.80 | 2 | 2 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 31 | 14.42 | 423 | 189 | 0.19 / 629.68 | 2 | 2 |
2 | 3 | 908.80 | -2 | 14.42 | 423 | 0 | 0.00 / 629.68 | 2 | 2 |
3 | 3 | 1083.80 | 2 | 12.22 | 1977 | 48 | 0.24 / 629.73 | 2 | 2 |
4 | 12 | 1165.60 | 6 | 11.70 | 2035 | 143 | 0.38 / 629.87 | 2 | 2 |
5 | 12 | 2001.44 | 10 | 9.51 | 3273 | 311 | 0.69 / 630.18 | 2 | 2 |
6 | 7 | 2001.08 | 55 | 10.51 | 3151 | 1821 | 2.51 / 632.00 | 2 | 2 |
7 | 13 | 1370.32 | 38 | 12.49 | 2345 | 1113 | 3.63 / 633.12 | 2 | 2 |
8 | 13 | 426.24 | 38 | 13.62 | 992 | 513 | 4.14 / 633.63 | 2 | 2 |
9 | 13 | 1.12 | 38 | 14.47 | 292 | 161 | 4.30 / 633.79 | 2 | 2 |
10 | 8 | -0.40 | 180 | 14.34 | 298 | 769 | 5.07 / 634.56 | 2 | 9 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 31 | 14.38 | 385 | 172 | 0.17 / 624.34 | 2 | 2 |
2 | 3 | 940.72 | -1 | 14.38 | 385 | 0 | 0.00 / 624.34 | 2 | 2 |
3 | 3 | 1055.08 | 1 | 11.20 | 1885 | 21 | 0.19 / 624.36 | 2 | 2 |
4 | 12 | 1159.40 | 6 | 10.84 | 1997 | 130 | 0.32 / 624.49 | 2 | 2 |
5 | 12 | 2004.80 | 10 | 7.91 | 2900 | 229 | 0.55 / 624.72 | 2 | 2 |
6 | 7 | 2005.88 | 55 | 10.53 | 3170 | 1836 | 2.39 / 626.55 | 2 | 2 |
7 | 13 | 1788.28 | 38 | 12.07 | 2910 | 1335 | 3.72 / 627.89 | 2 | 2 |
8 | 13 | 579.40 | 38 | 13.42 | 1239 | 632 | 4.35 / 628.52 | 2 | 2 |
9 | 13 | 34.52 | 38 | 14.38 | 356 | 195 | 4.55 / 628.71 | 2 | 2 |
10 | 8 | -0.32 | 180 | 14.38 | 301 | 779 | 5.33 / 629.49 | 2 | 4 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 31 | 14.34 | 399 | 177 | 0.18 / 619.02 | 2 | 2 |
2 | 3 | 946.80 | -1 | 14.34 | 399 | 0 | 0.00 / 619.02 | 2 | 2 |
3 | 3 | 1049.08 | 1 | 10.56 | 1847 | 20 | 0.20 / 619.04 | 2 | 2 |
4 | 12 | 1156.20 | 6 | 10.98 | 1985 | 131 | 0.33 / 619.17 | 2 | 2 |
5 | 12 | 2007.56 | 10 | 7.91 | 2944 | 233 | 0.56 / 619.41 | 2 | 2 |
6 | 7 | 2008.60 | 55 | 10.51 | 3174 | 1835 | 2.40 / 621.24 | 2 | 2 |
7 | 13 | 1788.36 | 38 | 12.05 | 2915 | 1335 | 3.73 / 622.58 | 2 | 2 |
8 | 13 | 568.80 | 38 | 13.43 | 1219 | 622 | 4.35 / 623.20 | 2 | 2 |
9 | 13 | 61.84 | 38 | 14.34 | 387 | 211 | 4.56 / 623.41 | 2 | 2 |
10 | 8 | -0.40 | 180 | 14.39 | 291 | 754 | 5.32 / 624.16 | 2 | 4 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 14.33 | 395 | 170 | 0.17 / 613.75 | 2 | 2 |
2 | 3 | 958.16 | -1 | 14.33 | 395 | 0 | 0.00 / 613.75 | 2 | 2 |
3 | 3 | 1068.88 | 2 | 11.71 | 1902 | 45 | 0.21 / 613.79 | 2 | 2 |
4 | 12 | 1147.24 | 6 | 11.66 | 1997 | 140 | 0.35 / 613.93 | 2 | 2 |
5 | 12 | 2002.72 | 10 | 8.91 | 2992 | 267 | 0.62 / 614.20 | 2 | 2 |
6 | 7 | 2003.08 | 55 | 10.50 | 3169 | 1830 | 2.45 / 616.03 | 2 | 2 |
7 | 13 | 1569.56 | 38 | 12.29 | 2613 | 1220 | 3.67 / 617.25 | 2 | 2 |
8 | 13 | 610.12 | 38 | 13.39 | 1273 | 648 | 4.32 / 617.90 | 2 | 2 |
9 | 13 | 35.04 | 38 | 14.39 | 347 | 190 | 4.51 / 618.09 | 2 | 2 |
10 | 8 | -0.24 | 180 | 14.39 | 294 | 762 | 5.27 / 618.85 | 2 | 4 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 30 | 14.43 | 405 | 175 | 0.18 / 608.44 | 2 | 2 |
2 | 3 | 963.48 | -1 | 14.43 | 405 | 0 | 0.00 / 608.44 | 2 | 2 |
3 | 3 | 1063.04 | 2 | 11.67 | 1921 | 45 | 0.22 / 608.48 | 2 | 2 |
4 | 12 | 1148.16 | 6 | 11.75 | 2015 | 142 | 0.36 / 608.62 | 2 | 2 |
5 | 12 | 2003.72 | 10 | 10.11 | 3196 | 323 | 0.69 / 608.95 | 2 | 2 |
6 | 7 | 2003.92 | 55 | 10.46 | 3186 | 1833 | 2.52 / 610.78 | 2 | 2 |
7 | 13 | 1562.80 | 38 | 12.24 | 2628 | 1222 | 3.74 / 612.00 | 2 | 2 |
8 | 13 | 547.64 | 38 | 13.42 | 1201 | 612 | 4.35 / 612.61 | 2 | 2 |
9 | 13 | 50.96 | 38 | 14.34 | 371 | 202 | 4.56 / 612.82 | 2 | 2 |
10 | 8 | -0.36 | 180 | 14.37 | 294 | 760 | 5.32 / 613.58 | 2 | 4 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 30 | 14.45 | 423 | 183 | 0.18 / 603.07 | 2 | 2 |
2 | 3 | 940.48 | -1 | 14.45 | 423 | 0 | 0.00 / 603.07 | 2 | 2 |
3 | 3 | 1035.24 | 1 | 11.73 | 1863 | 22 | 0.21 / 603.09 | 2 | 2 |
4 | 12 | 1136.16 | 6 | 11.62 | 1968 | 137 | 0.34 / 603.22 | 2 | 2 |
5 | 12 | 2003.52 | 10 | 10.19 | 3185 | 325 | 0.67 / 603.55 | 2 | 2 |
6 | 7 | 2003.20 | 55 | 10.35 | 3185 | 1813 | 2.48 / 605.36 | 2 | 2 |
7 | 13 | 1782.52 | 38 | 11.98 | 2899 | 1320 | 3.80 / 606.68 | 2 | 2 |
8 | 13 | 555.56 | 38 | 13.43 | 1194 | 609 | 4.41 / 607.29 | 2 | 2 |
9 | 13 | 56.08 | 38 | 14.34 | 380 | 207 | 4.62 / 607.50 | 2 | 2 |
10 | 8 | -0.36 | 180 | 14.37 | 295 | 763 | 5.38 / 608.26 | 2 | 4 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 30 | 14.44 | 440 | 191 | 0.19 / 597.78 | 2 | 2 |
2 | 3 | 973.32 | -1 | 14.44 | 440 | 0 | 0.00 / 597.78 | 2 | 2 |
3 | 3 | 1085.88 | 2 | 12.19 | 1952 | 48 | 0.24 / 597.83 | 2 | 2 |
4 | 12 | 1148.80 | 6 | 11.74 | 1976 | 139 | 0.38 / 597.97 | 2 | 2 |
5 | 12 | 2001.88 | 10 | 10.38 | 3169 | 329 | 0.71 / 598.30 | 2 | 2 |
6 | 7 | 2001.32 | 55 | 10.39 | 3152 | 1801 | 2.51 / 600.10 | 2 | 2 |
7 | 13 | 1541.52 | 38 | 12.27 | 2582 | 1204 | 3.71 / 601.30 | 2 | 2 |
8 | 13 | 540.80 | 38 | 13.46 | 1171 | 599 | 4.31 / 601.90 | 2 | 2 |
9 | 13 | 64.16 | 38 | 14.34 | 393 | 214 | 4.52 / 602.12 | 2 | 2 |
10 | 8 | -0.36 | 180 | 14.39 | 295 | 764 | 5.29 / 602.88 | 2 | 5 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 28 | 14.39 | 401 | 162 | 0.16 / 592.50 | 2 | 2 |
2 | 3 | 1031.00 | 1 | 10.12 | 1816 | 18 | 0.18 / 592.52 | 2 | 2 |
3 | 12 | 1122.44 | 6 | 11.63 | 1972 | 138 | 0.32 / 592.66 | 2 | 2 |
4 | 12 | 2000.56 | 10 | 9.02 | 3023 | 273 | 0.59 / 592.93 | 2 | 2 |
5 | 7 | 2000.64 | 55 | 10.34 | 3179 | 1808 | 2.40 / 594.74 | 2 | 2 |
6 | 13 | 1556.68 | 38 | 12.28 | 2614 | 1220 | 3.62 / 595.96 | 2 | 2 |
7 | 13 | 587.04 | 38 | 13.43 | 1246 | 636 | 4.25 / 596.59 | 2 | 2 |
8 | 13 | 61.68 | 38 | 14.34 | 398 | 217 | 4.47 / 596.81 | 2 | 2 |
9 | 8 | -0.20 | 180 | 14.38 | 302 | 782 | 5.25 / 597.59 | 2 | 6 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 30 | 14.42 | 437 | 189 | 0.19 / 589.42 | 2 | 2 |
2 | 3 | 968.96 | -1 | 14.42 | 437 | 0 | 0.00 / 589.42 | 2 | 2 |
3 | 12 | 1077.08 | 6 | 11.85 | 1905 | 135 | 0.32 / 589.55 | 2 | 2 |
4 | 12 | 1237.28 | 10 | 11.55 | 2142 | 247 | 0.57 / 589.80 | 2 | 2 |
5 | 7 | 1236.20 | 55 | 11.53 | 2120 | 1344 | 1.92 / 591.14 | 2 | 2 |
6 | 13 | 317.56 | 38 | 13.71 | 829 | 432 | 2.35 / 591.58 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.36 | 296 | 765 | 3.11 / 592.34 | 2 | 3 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.43 | 421 | 182 | 0.18 / 584.50 | 2 | 2 |
2 | 3 | 942.80 | -1 | 14.43 | 421 | 0 | 0.00 / 584.50 | 2 | 2 |
3 | 3 | 1037.04 | 1 | 11.86 | 1868 | 22 | 0.20 / 584.52 | 2 | 2 |
4 | 12 | 1157.00 | 6 | 11.66 | 2046 | 143 | 0.35 / 584.66 | 2 | 2 |
5 | 12 | 2002.88 | 10 | 10.74 | 3211 | 345 | 0.69 / 585.01 | 2 | 2 |
6 | 7 | 2002.52 | 55 | 10.61 | 3177 | 1854 | 2.55 / 586.86 | 2 | 2 |
7 | 13 | 1344.36 | 38 | 12.48 | 2318 | 1099 | 3.65 / 587.96 | 2 | 2 |
8 | 13 | 424.24 | 38 | 13.61 | 985 | 509 | 4.16 / 588.47 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.37 | 292 | 755 | 4.91 / 589.23 | 2 | 4 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 30 | 14.40 | 442 | 191 | 0.19 / 579.56 | 2 | 2 |
2 | 3 | 957.72 | -1 | 14.40 | 442 | 0 | 0.00 / 579.56 | 2 | 2 |
3 | 3 | 1053.60 | 1 | 11.99 | 1896 | 23 | 0.21 / 579.58 | 2 | 2 |
4 | 12 | 1144.24 | 6 | 11.76 | 2006 | 142 | 0.36 / 579.72 | 2 | 2 |
5 | 12 | 2001.32 | 10 | 10.61 | 3159 | 335 | 0.69 / 580.06 | 2 | 2 |
6 | 7 | 2000.48 | 55 | 10.59 | 3162 | 1842 | 2.53 / 581.90 | 2 | 2 |
7 | 13 | 1533.92 | 38 | 12.26 | 2583 | 1203 | 3.74 / 583.10 | 2 | 2 |
8 | 13 | 345.16 | 38 | 13.73 | 872 | 455 | 4.19 / 583.56 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.36 | 294 | 760 | 4.95 / 584.32 | 2 | 2 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 30 | 14.44 | 426 | 185 | 0.18 / 574.64 | 2 | 2 |
2 | 3 | 944.68 | -1 | 14.44 | 426 | 0 | 0.00 / 574.64 | 2 | 2 |
3 | 3 | 1048.08 | 1 | 11.97 | 1903 | 23 | 0.21 / 574.67 | 2 | 2 |
4 | 12 | 1136.84 | 6 | 11.83 | 1979 | 140 | 0.35 / 574.81 | 2 | 2 |
5 | 12 | 2002.28 | 10 | 10.50 | 3188 | 335 | 0.68 / 575.14 | 2 | 2 |
6 | 7 | 2001.68 | 55 | 10.58 | 3172 | 1846 | 2.53 / 576.99 | 2 | 2 |
7 | 13 | 1348.88 | 38 | 12.49 | 2329 | 1105 | 3.63 / 578.09 | 2 | 2 |
8 | 13 | 401.40 | 38 | 13.64 | 964 | 500 | 4.13 / 578.59 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.35 | 300 | 775 | 4.91 / 579.37 | 2 | 3 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 30 | 14.41 | 432 | 187 | 0.19 / 569.75 | 2 | 2 |
2 | 3 | 970.44 | -1 | 14.41 | 432 | 0 | 0.00 / 569.75 | 2 | 2 |
3 | 3 | 1064.40 | 2 | 11.91 | 1913 | 46 | 0.23 / 569.79 | 2 | 2 |
4 | 12 | 1150.24 | 6 | 11.84 | 2037 | 145 | 0.38 / 569.94 | 2 | 2 |
5 | 12 | 2002.84 | 10 | 10.61 | 3203 | 340 | 0.72 / 570.28 | 2 | 2 |
6 | 7 | 2002.20 | 54 | 10.63 | 3184 | 1828 | 2.54 / 572.11 | 2 | 2 |
7 | 13 | 1347.36 | 38 | 12.49 | 2331 | 1106 | 3.65 / 573.21 | 2 | 2 |
8 | 13 | 379.28 | 38 | 13.68 | 925 | 481 | 4.13 / 573.69 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.37 | 296 | 766 | 4.90 / 574.46 | 2 | 2 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 30 | 14.43 | 414 | 179 | 0.18 / 564.45 | 2 | 2 |
2 | 3 | 936.60 | -1 | 14.43 | 414 | 0 | 0.00 / 564.45 | 2 | 2 |
3 | 3 | 1039.24 | 1 | 11.89 | 1870 | 22 | 0.20 / 564.48 | 2 | 2 |
4 | 12 | 1137.08 | 6 | 11.81 | 2006 | 142 | 0.34 / 564.62 | 2 | 2 |
5 | 12 | 2002.36 | 10 | 10.67 | 3196 | 341 | 0.68 / 564.96 | 2 | 2 |
6 | 7 | 2001.88 | 55 | 10.64 | 3177 | 1859 | 2.54 / 566.82 | 2 | 2 |
7 | 13 | 1543.84 | 38 | 12.30 | 2581 | 1206 | 3.75 / 568.02 | 2 | 2 |
8 | 13 | 508.68 | 38 | 13.51 | 1121 | 575 | 4.33 / 568.60 | 2 | 2 |
9 | 13 | 3.92 | 38 | 14.44 | 310 | 170 | 4.50 / 568.77 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.32 | 307 | 791 | 5.29 / 569.56 | 2 | 7 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 30 | 14.44 | 423 | 183 | 0.18 / 559.43 | 2 | 2 |
2 | 3 | 943.64 | -1 | 14.44 | 423 | 0 | 0.00 / 559.43 | 2 | 2 |
3 | 3 | 1054.00 | 1 | 12.02 | 1899 | 23 | 0.21 / 559.45 | 2 | 2 |
4 | 12 | 1137.04 | 6 | 11.97 | 2015 | 145 | 0.35 / 559.60 | 2 | 2 |
5 | 12 | 2002.72 | 10 | 10.62 | 3198 | 340 | 0.69 / 559.94 | 2 | 2 |
6 | 7 | 2002.04 | 54 | 10.68 | 3174 | 1831 | 2.52 / 561.77 | 2 | 2 |
7 | 13 | 1343.68 | 38 | 12.53 | 2314 | 1102 | 3.62 / 562.87 | 2 | 2 |
8 | 13 | 591.12 | 38 | 13.39 | 1259 | 641 | 4.26 / 563.51 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.37 | 295 | 763 | 5.03 / 564.27 | 2 | 4 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 30 | 14.44 | 427 | 185 | 0.18 / 554.35 | 2 | 2 |
2 | 3 | 944.56 | -1 | 14.44 | 427 | 0 | 0.00 / 554.35 | 2 | 2 |
3 | 3 | 1050.24 | 1 | 11.98 | 1901 | 23 | 0.21 / 554.37 | 2 | 2 |
4 | 12 | 1149.44 | 6 | 11.92 | 2012 | 144 | 0.35 / 554.51 | 2 | 2 |
5 | 12 | 2001.00 | 10 | 10.85 | 3189 | 346 | 0.70 / 554.86 | 2 | 2 |
6 | 7 | 2000.52 | 55 | 10.70 | 3166 | 1863 | 2.56 / 556.72 | 2 | 2 |
7 | 13 | 1539.64 | 38 | 12.32 | 2583 | 1209 | 3.77 / 557.93 | 2 | 2 |
8 | 13 | 508.12 | 38 | 13.52 | 1112 | 571 | 4.34 / 558.50 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.39 | 288 | 746 | 5.09 / 559.25 | 2 | 2 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 30 | 14.43 | 409 | 177 | 0.18 / 549.23 | 2 | 2 |
2 | 3 | 971.40 | -1 | 14.43 | 409 | 0 | 0.00 / 549.23 | 2 | 2 |
3 | 3 | 1069.24 | 2 | 11.98 | 1898 | 45 | 0.22 / 549.27 | 2 | 2 |
4 | 12 | 1136.64 | 6 | 12.03 | 1995 | 144 | 0.37 / 549.41 | 2 | 2 |
5 | 12 | 2000.96 | 10 | 10.79 | 3201 | 345 | 0.71 / 549.76 | 2 | 2 |
6 | 7 | 2000.64 | 55 | 10.69 | 3162 | 1859 | 2.57 / 551.62 | 2 | 2 |
7 | 13 | 1557.32 | 38 | 12.33 | 2593 | 1215 | 3.79 / 552.83 | 2 | 2 |
8 | 13 | 542.08 | 38 | 13.50 | 1154 | 592 | 4.38 / 553.43 | 2 | 2 |
9 | 8 | -0.12 | 180 | 14.41 | 283 | 734 | 5.11 / 554.16 | 2 | 2 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 30 | 14.43 | 427 | 185 | 0.18 / 544.10 | 2 | 2 |
2 | 3 | 947.88 | -1 | 14.43 | 427 | 0 | 0.00 / 544.10 | 2 | 2 |
3 | 3 | 1042.00 | 1 | 12.02 | 1865 | 22 | 0.21 / 544.12 | 2 | 2 |
4 | 12 | 1136.60 | 6 | 11.92 | 2008 | 144 | 0.35 / 544.27 | 2 | 2 |
5 | 12 | 2005.64 | 10 | 10.77 | 3207 | 345 | 0.70 / 544.61 | 2 | 2 |
6 | 7 | 2004.80 | 55 | 10.74 | 3178 | 1877 | 2.57 / 546.49 | 2 | 2 |
7 | 13 | 1525.28 | 38 | 12.33 | 2581 | 1209 | 3.78 / 547.70 | 2 | 2 |
8 | 13 | 518.04 | 38 | 13.51 | 1128 | 579 | 4.36 / 548.28 | 2 | 2 |
9 | 8 | -0.08 | 180 | 14.37 | 298 | 771 | 5.13 / 549.05 | 2 | 2 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 30 | 14.42 | 448 | 194 | 0.19 / 538.90 | 2 | 2 |
2 | 3 | 959.40 | -1 | 14.42 | 448 | 0 | 0.00 / 538.90 | 2 | 2 |
3 | 3 | 1058.48 | 2 | 12.10 | 1910 | 46 | 0.24 / 538.94 | 2 | 2 |
4 | 12 | 1135.48 | 6 | 11.81 | 2039 | 144 | 0.38 / 539.09 | 2 | 2 |
5 | 12 | 2003.40 | 10 | 10.84 | 3215 | 349 | 0.73 / 539.44 | 2 | 2 |
6 | 7 | 2002.76 | 55 | 10.74 | 3183 | 1880 | 2.61 / 541.32 | 2 | 2 |
7 | 13 | 1552.28 | 38 | 12.32 | 2609 | 1221 | 3.83 / 542.54 | 2 | 2 |
8 | 13 | 543.08 | 38 | 13.48 | 1168 | 598 | 4.43 / 543.14 | 2 | 2 |
9 | 8 | -0.20 | 180 | 14.36 | 301 | 778 | 5.21 / 543.92 | 2 | 3 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 29 | 14.44 | 436 | 183 | 0.18 / 533.55 | 2 | 2 |
2 | 3 | 973.20 | -1 | 14.44 | 436 | 0 | 0.00 / 533.55 | 2 | 2 |
3 | 3 | 1074.52 | 2 | 12.16 | 1940 | 47 | 0.23 / 533.59 | 2 | 2 |
4 | 12 | 1151.32 | 6 | 11.88 | 2042 | 146 | 0.38 / 533.74 | 2 | 2 |
5 | 12 | 2002.76 | 10 | 10.64 | 3231 | 344 | 0.72 / 534.08 | 2 | 2 |
6 | 7 | 2002.12 | 55 | 10.71 | 3183 | 1875 | 2.59 / 535.96 | 2 | 2 |
7 | 13 | 1546.68 | 38 | 12.33 | 2597 | 1217 | 3.81 / 537.17 | 2 | 2 |
8 | 13 | 509.84 | 38 | 13.52 | 1122 | 576 | 4.39 / 537.75 | 2 | 2 |
9 | 13 | 2.76 | 38 | 14.45 | 309 | 170 | 4.56 / 537.92 | 2 | 2 |
10 | 8 | -0.28 | 180 | 14.32 | 304 | 784 | 5.34 / 538.70 | 2 | 7 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 29 | 14.40 | 463 | 193 | 0.19 / 528.66 | 2 | 2 |
2 | 12 | 1096.24 | 6 | 12.02 | 1939 | 140 | 0.33 / 528.80 | 2 | 2 |
3 | 12 | 2001.20 | 10 | 10.84 | 3195 | 346 | 0.68 / 529.14 | 2 | 2 |
4 | 7 | 2000.52 | 54 | 10.71 | 3179 | 1839 | 2.52 / 530.98 | 2 | 2 |
5 | 13 | 1359.80 | 38 | 12.54 | 2334 | 1112 | 3.63 / 532.09 | 2 | 2 |
6 | 13 | 382.84 | 38 | 13.68 | 934 | 486 | 4.12 / 532.58 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.33 | 304 | 784 | 4.90 / 533.36 | 2 | 3 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 14.37 | 406 | 169 | 0.17 / 523.65 | 2 | 2 |
2 | 12 | 1106.72 | 6 | 11.95 | 1978 | 142 | 0.31 / 523.79 | 2 | 2 |
3 | 12 | 2002.24 | 10 | 10.49 | 3189 | 335 | 0.65 / 524.12 | 2 | 2 |
4 | 7 | 2001.92 | 55 | 10.64 | 3185 | 1864 | 2.51 / 525.99 | 2 | 2 |
5 | 13 | 1528.32 | 38 | 12.35 | 2572 | 1207 | 3.72 / 527.19 | 2 | 2 |
6 | 13 | 326.32 | 38 | 13.78 | 866 | 453 | 4.17 / 527.65 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.32 | 317 | 817 | 4.99 / 528.46 | 2 | 2 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 29 | 14.35 | 419 | 174 | 0.17 / 518.55 | 2 | 2 |
2 | 12 | 1121.56 | 6 | 11.97 | 2007 | 144 | 0.32 / 518.69 | 2 | 2 |
3 | 12 | 2003.36 | 10 | 10.42 | 3217 | 335 | 0.65 / 519.03 | 2 | 2 |
4 | 7 | 2002.96 | 55 | 10.66 | 3197 | 1874 | 2.53 / 520.90 | 2 | 2 |
5 | 13 | 1522.16 | 38 | 12.37 | 2567 | 1207 | 3.73 / 522.11 | 2 | 2 |
6 | 13 | 502.00 | 38 | 13.53 | 1139 | 586 | 4.32 / 522.69 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.34 | 304 | 785 | 5.11 / 523.48 | 2 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 29 | 14.35 | 423 | 176 | 0.18 / 513.63 | 2 | 2 |
2 | 12 | 1122.28 | 6 | 12.03 | 2005 | 145 | 0.32 / 513.77 | 2 | 2 |
3 | 12 | 2006.40 | 10 | 10.82 | 3218 | 348 | 0.67 / 514.12 | 2 | 2 |
4 | 7 | 2006.36 | 55 | 10.68 | 3183 | 1870 | 2.54 / 515.99 | 2 | 2 |
5 | 13 | 1354.32 | 38 | 12.58 | 2338 | 1118 | 3.66 / 517.11 | 2 | 2 |
6 | 13 | 375.56 | 38 | 13.74 | 913 | 477 | 4.13 / 517.58 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.34 | 305 | 787 | 4.92 / 518.37 | 2 | 4 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 29 | 14.43 | 463 | 194 | 0.19 / 508.66 | 2 | 2 |
2 | 12 | 1098.12 | 6 | 11.97 | 1958 | 141 | 0.33 / 508.80 | 2 | 2 |
3 | 12 | 1989.16 | 10 | 10.73 | 3204 | 344 | 0.68 / 509.14 | 2 | 2 |
4 | 7 | 1987.84 | 55 | 10.74 | 3176 | 1876 | 2.55 / 511.02 | 2 | 2 |
5 | 13 | 1512.88 | 38 | 12.40 | 2574 | 1213 | 3.77 / 512.23 | 2 | 2 |
6 | 13 | 297.48 | 38 | 13.86 | 806 | 425 | 4.19 / 512.65 | 2 | 2 |
7 | 8 | -0.24 | 180 | 14.34 | 309 | 798 | 4.99 / 513.45 | 2 | 2 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 29 | 14.35 | 426 | 177 | 0.18 / 503.69 | 2 | 2 |
2 | 12 | 1136.68 | 6 | 12.05 | 2028 | 147 | 0.32 / 503.83 | 2 | 2 |
3 | 12 | 2002.96 | 10 | 10.77 | 3219 | 347 | 0.67 / 504.18 | 2 | 2 |
4 | 7 | 2002.76 | 54 | 10.69 | 3192 | 1843 | 2.51 / 506.02 | 2 | 2 |
5 | 13 | 1343.28 | 38 | 12.60 | 2332 | 1117 | 3.63 / 507.14 | 2 | 2 |
6 | 13 | 396.60 | 38 | 13.70 | 965 | 502 | 4.13 / 507.64 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.35 | 318 | 821 | 4.95 / 508.46 | 2 | 2 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 29 | 14.48 | 428 | 180 | 0.18 / 498.76 | 2 | 2 |
2 | 3 | 965.36 | -1 | 14.48 | 428 | 0 | 0.00 / 498.76 | 2 | 2 |
3 | 3 | 1054.96 | 1 | 12.35 | 1899 | 23 | 0.20 / 498.78 | 2 | 2 |
4 | 12 | 1143.76 | 6 | 12.06 | 2025 | 147 | 0.35 / 498.93 | 2 | 2 |
5 | 12 | 1987.80 | 10 | 11.05 | 3213 | 355 | 0.70 / 499.28 | 2 | 2 |
6 | 7 | 1986.64 | 55 | 10.84 | 3185 | 1899 | 2.60 / 501.18 | 2 | 2 |
7 | 13 | 1322.84 | 38 | 12.62 | 2288 | 1097 | 3.70 / 502.28 | 2 | 2 |
8 | 13 | 340.32 | 38 | 13.77 | 879 | 460 | 4.16 / 502.74 | 2 | 2 |
9 | 8 | -0.20 | 180 | 14.35 | 299 | 772 | 4.93 / 503.51 | 2 | 3 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 30 | 14.47 | 425 | 184 | 0.18 / 493.80 | 2 | 2 |
2 | 3 | 940.04 | -1 | 14.47 | 425 | 0 | 0.00 / 493.80 | 2 | 2 |
3 | 3 | 1029.80 | 1 | 11.81 | 1869 | 22 | 0.21 / 493.82 | 2 | 2 |
4 | 12 | 1145.48 | 6 | 12.06 | 2032 | 147 | 0.35 / 493.97 | 2 | 2 |
5 | 12 | 1994.96 | 10 | 11.02 | 3213 | 354 | 0.71 / 494.33 | 2 | 2 |
6 | 7 | 1994.32 | 55 | 10.87 | 3196 | 1911 | 2.62 / 496.24 | 2 | 2 |
7 | 13 | 1334.84 | 38 | 12.63 | 2301 | 1104 | 3.72 / 497.34 | 2 | 2 |
8 | 13 | 349.12 | 38 | 13.78 | 870 | 456 | 4.18 / 497.80 | 2 | 2 |
9 | 8 | 0.16 | 180 | 14.34 | 302 | 780 | 4.96 / 498.58 | 2 | 4 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 30 | 14.46 | 441 | 191 | 0.19 / 488.74 | 2 | 2 |
2 | 3 | 953.12 | -1 | 14.46 | 441 | 0 | 0.00 / 488.74 | 2 | 2 |
3 | 3 | 1055.64 | 1 | 12.28 | 1907 | 23 | 0.21 / 488.76 | 2 | 2 |
4 | 12 | 1143.96 | 6 | 12.15 | 2020 | 147 | 0.36 / 488.91 | 2 | 2 |
5 | 12 | 2001.00 | 10 | 11.19 | 3206 | 359 | 0.72 / 489.27 | 2 | 2 |
6 | 7 | 2000.12 | 54 | 10.89 | 3180 | 1870 | 2.59 / 491.14 | 2 | 2 |
7 | 13 | 1327.72 | 38 | 12.64 | 2295 | 1102 | 3.69 / 492.24 | 2 | 2 |
8 | 13 | 345.80 | 38 | 13.80 | 858 | 450 | 4.14 / 492.69 | 2 | 2 |
9 | 13 | 2.36 | 38 | 14.48 | 295 | 162 | 4.31 / 492.85 | 2 | 2 |
10 | 8 | -0.20 | 180 | 14.32 | 298 | 768 | 5.07 / 493.62 | 2 | 9 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 30 | 14.49 | 433 | 188 | 0.19 / 483.83 | 2 | 2 |
2 | 3 | 959.72 | -1 | 14.49 | 433 | 0 | 0.00 / 483.83 | 2 | 2 |
3 | 3 | 1051.28 | 1 | 12.29 | 1902 | 23 | 0.21 / 483.86 | 2 | 2 |
4 | 12 | 1130.00 | 6 | 12.14 | 1996 | 145 | 0.36 / 484.00 | 2 | 2 |
5 | 12 | 1992.32 | 10 | 11.20 | 3190 | 357 | 0.71 / 484.36 | 2 | 2 |
6 | 7 | 1991.36 | 55 | 10.92 | 3163 | 1900 | 2.61 / 486.26 | 2 | 2 |
7 | 13 | 1293.20 | 38 | 12.69 | 2241 | 1081 | 3.69 / 487.34 | 2 | 2 |
8 | 13 | 318.28 | 38 | 13.86 | 812 | 428 | 4.12 / 487.77 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.35 | 301 | 777 | 4.90 / 488.54 | 2 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 30 | 14.47 | 455 | 198 | 0.20 / 478.68 | 2 | 2 |
2 | 3 | 955.32 | -1 | 14.47 | 455 | 0 | 0.00 / 478.68 | 2 | 2 |
3 | 3 | 1047.16 | 1 | 12.30 | 1903 | 23 | 0.22 / 478.70 | 2 | 2 |
4 | 12 | 1146.44 | 6 | 12.11 | 2037 | 148 | 0.37 / 478.85 | 2 | 2 |
5 | 12 | 1996.00 | 10 | 11.15 | 3204 | 357 | 0.73 / 479.21 | 2 | 2 |
6 | 7 | 1994.84 | 54 | 10.93 | 3186 | 1880 | 2.61 / 481.09 | 2 | 2 |
7 | 13 | 1514.40 | 38 | 12.47 | 2580 | 1223 | 3.83 / 482.31 | 2 | 2 |
8 | 13 | 485.32 | 38 | 13.58 | 1112 | 574 | 4.40 / 482.88 | 2 | 2 |
9 | 8 | -0.28 | 180 | 14.36 | 295 | 763 | 5.17 / 483.64 | 2 | 3 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 29 | 14.48 | 450 | 189 | 0.19 / 473.23 | 2 | 2 |
2 | 3 | 969.40 | -1 | 14.48 | 450 | 0 | 0.00 / 473.23 | 2 | 2 |
3 | 3 | 1063.08 | 2 | 12.40 | 1927 | 48 | 0.24 / 473.27 | 2 | 2 |
4 | 12 | 1140.20 | 6 | 12.08 | 2048 | 148 | 0.39 / 473.42 | 2 | 2 |
5 | 12 | 1997.24 | 10 | 11.15 | 3229 | 360 | 0.75 / 473.78 | 2 | 2 |
6 | 7 | 1996.00 | 54 | 10.94 | 3191 | 1885 | 2.63 / 475.67 | 2 | 2 |
7 | 13 | 1522.12 | 38 | 12.47 | 2578 | 1222 | 3.85 / 476.89 | 2 | 2 |
8 | 13 | 511.76 | 38 | 13.58 | 1122 | 579 | 4.43 / 477.47 | 2 | 2 |
9 | 13 | 43.24 | 38 | 14.37 | 385 | 210 | 4.64 / 477.68 | 2 | 2 |
10 | 8 | -0.36 | 180 | 14.34 | 310 | 800 | 5.44 / 478.48 | 2 | 7 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 29 | 14.49 | 442 | 186 | 0.19 / 468.26 | 2 | 2 |
2 | 3 | 960.68 | -1 | 14.49 | 442 | 0 | 0.00 / 468.26 | 2 | 2 |
3 | 3 | 1046.28 | 1 | 12.27 | 1908 | 23 | 0.21 / 468.28 | 2 | 2 |
4 | 12 | 1153.64 | 6 | 12.17 | 2030 | 148 | 0.36 / 468.43 | 2 | 2 |
5 | 12 | 2001.16 | 10 | 11.10 | 3226 | 358 | 0.72 / 468.78 | 2 | 2 |
6 | 7 | 2000.32 | 54 | 10.91 | 3197 | 1883 | 2.60 / 470.67 | 2 | 2 |
7 | 13 | 1316.60 | 38 | 12.68 | 2303 | 1110 | 3.71 / 471.78 | 2 | 2 |
8 | 13 | 344.32 | 38 | 13.81 | 870 | 457 | 4.17 / 472.23 | 2 | 2 |
9 | 8 | -0.20 | 180 | 14.35 | 311 | 803 | 4.97 / 473.04 | 2 | 2 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 30 | 14.51 | 433 | 188 | 0.19 / 463.13 | 2 | 2 |
2 | 3 | 949.84 | -1 | 14.51 | 433 | 0 | 0.00 / 463.13 | 2 | 2 |
3 | 3 | 1043.52 | 1 | 12.30 | 1903 | 23 | 0.21 / 463.15 | 2 | 2 |
4 | 12 | 1137.76 | 6 | 12.15 | 2023 | 147 | 0.36 / 463.30 | 2 | 2 |
5 | 12 | 2000.12 | 10 | 11.27 | 3220 | 363 | 0.72 / 463.66 | 2 | 2 |
6 | 7 | 1999.44 | 55 | 10.96 | 3188 | 1922 | 2.64 / 465.58 | 2 | 2 |
7 | 13 | 1314.48 | 38 | 12.72 | 2281 | 1103 | 3.75 / 466.69 | 2 | 2 |
8 | 13 | 542.68 | 38 | 13.54 | 1201 | 618 | 4.36 / 467.30 | 2 | 2 |
9 | 8 | -0.16 | 180 | 14.38 | 296 | 766 | 5.13 / 468.07 | 2 | 2 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 14.53 | 425 | 179 | 0.18 / 458.19 | 2 | 2 |
2 | 3 | 970.08 | -1 | 14.53 | 425 | 0 | 0.00 / 458.19 | 2 | 2 |
3 | 3 | 1073.56 | 2 | 12.33 | 1936 | 48 | 0.23 / 458.24 | 2 | 2 |
4 | 12 | 1147.00 | 6 | 12.20 | 2030 | 149 | 0.38 / 458.39 | 2 | 2 |
5 | 12 | 1995.36 | 10 | 11.15 | 3222 | 359 | 0.73 / 458.75 | 2 | 2 |
6 | 7 | 1994.24 | 54 | 11.00 | 3173 | 1885 | 2.62 / 460.63 | 2 | 2 |
7 | 13 | 1316.72 | 38 | 12.74 | 2270 | 1099 | 3.72 / 461.73 | 2 | 2 |
8 | 13 | 334.00 | 38 | 13.84 | 861 | 453 | 4.17 / 462.18 | 2 | 2 |
9 | 8 | -0.24 | 180 | 14.38 | 292 | 756 | 4.93 / 462.94 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 14.52 | 432 | 182 | 0.18 / 453.23 | 2 | 2 |
2 | 3 | 969.96 | -1 | 14.52 | 432 | 0 | 0.00 / 453.23 | 2 | 2 |
3 | 3 | 1056.76 | 1 | 12.46 | 1910 | 24 | 0.21 / 453.26 | 2 | 2 |
4 | 12 | 1144.00 | 6 | 12.27 | 2022 | 149 | 0.35 / 453.41 | 2 | 2 |
5 | 12 | 1992.48 | 10 | 11.27 | 3228 | 364 | 0.72 / 453.77 | 2 | 2 |
6 | 7 | 1991.40 | 55 | 10.99 | 3180 | 1922 | 2.64 / 455.69 | 2 | 2 |
7 | 13 | 1304.64 | 38 | 12.73 | 2295 | 1110 | 3.75 / 456.80 | 2 | 2 |
8 | 13 | 318.52 | 38 | 13.88 | 835 | 440 | 4.19 / 457.24 | 2 | 2 |
9 | 8 | -0.36 | 180 | 14.36 | 297 | 768 | 4.96 / 458.01 | 2 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 29 | 14.45 | 417 | 175 | 0.17 / 448.10 | 2 | 2 |
2 | 12 | 1121.76 | 6 | 12.16 | 1991 | 145 | 0.32 / 448.25 | 2 | 2 |
3 | 12 | 2001.32 | 10 | 10.84 | 3205 | 347 | 0.67 / 448.60 | 2 | 2 |
4 | 7 | 2000.28 | 54 | 10.91 | 3190 | 1879 | 2.55 / 450.48 | 2 | 2 |
5 | 13 | 1529.36 | 38 | 12.54 | 2575 | 1227 | 3.77 / 451.70 | 2 | 2 |
6 | 13 | 508.80 | 38 | 13.62 | 1123 | 581 | 4.36 / 452.28 | 2 | 2 |
7 | 8 | 0.08 | 180 | 14.37 | 297 | 768 | 5.12 / 453.05 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 29 | 14.54 | 427 | 180 | 0.18 / 443.20 | 2 | 2 |
2 | 12 | 1122.64 | 6 | 12.25 | 2005 | 147 | 0.33 / 443.34 | 2 | 2 |
3 | 12 | 1993.56 | 10 | 11.09 | 3218 | 357 | 0.68 / 443.70 | 2 | 2 |
4 | 7 | 1992.92 | 55 | 10.99 | 3178 | 1921 | 2.61 / 445.62 | 2 | 2 |
5 | 13 | 1310.84 | 38 | 12.76 | 2273 | 1102 | 3.71 / 446.72 | 2 | 2 |
6 | 13 | 324.80 | 38 | 13.88 | 829 | 437 | 4.14 / 447.16 | 2 | 2 |
7 | 8 | -0.32 | 180 | 14.37 | 297 | 768 | 4.91 / 447.93 | 2 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 29 | 14.49 | 405 | 170 | 0.17 / 438.23 | 2 | 2 |
2 | 12 | 1120.64 | 6 | 12.29 | 1979 | 146 | 0.32 / 438.38 | 2 | 2 |
3 | 12 | 2001.16 | 10 | 10.93 | 3234 | 353 | 0.67 / 438.73 | 2 | 2 |
4 | 7 | 2000.24 | 54 | 10.97 | 3210 | 1902 | 2.57 / 440.63 | 2 | 2 |
5 | 13 | 1341.80 | 38 | 12.73 | 2340 | 1132 | 3.70 / 441.76 | 2 | 2 |
6 | 13 | 368.72 | 38 | 13.82 | 905 | 475 | 4.18 / 442.24 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.37 | 301 | 779 | 4.96 / 443.02 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 29 | 14.55 | 436 | 184 | 0.18 / 433.34 | 2 | 2 |
2 | 12 | 1107.92 | 6 | 12.27 | 1976 | 145 | 0.33 / 433.48 | 2 | 2 |
3 | 12 | 1989.72 | 10 | 11.11 | 3197 | 355 | 0.68 / 433.84 | 2 | 2 |
4 | 7 | 1988.48 | 54 | 11.07 | 3198 | 1912 | 2.60 / 435.75 | 2 | 2 |
5 | 13 | 1304.84 | 38 | 12.80 | 2271 | 1105 | 3.70 / 436.86 | 2 | 2 |
6 | 13 | 317.28 | 38 | 13.90 | 824 | 435 | 4.14 / 437.29 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.39 | 297 | 769 | 4.91 / 438.06 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 29 | 14.53 | 428 | 180 | 0.18 / 428.41 | 2 | 2 |
2 | 12 | 1120.92 | 6 | 12.39 | 1991 | 148 | 0.33 / 428.56 | 2 | 2 |
3 | 12 | 1999.24 | 10 | 11.11 | 3223 | 358 | 0.69 / 428.92 | 2 | 2 |
4 | 7 | 1998.12 | 54 | 11.13 | 3189 | 1917 | 2.60 / 430.84 | 2 | 2 |
5 | 13 | 1322.28 | 38 | 12.80 | 2287 | 1112 | 3.72 / 431.95 | 2 | 2 |
6 | 13 | 321.68 | 38 | 13.92 | 819 | 433 | 4.15 / 432.38 | 2 | 2 |
7 | 8 | -0.04 | 180 | 14.38 | 298 | 771 | 4.92 / 433.15 | 2 | 3 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 29 | 14.54 | 425 | 179 | 0.18 / 423.24 | 2 | 2 |
2 | 12 | 1109.16 | 6 | 12.29 | 1985 | 146 | 0.33 / 423.39 | 2 | 2 |
3 | 12 | 1989.72 | 10 | 11.14 | 3241 | 361 | 0.69 / 423.75 | 2 | 2 |
4 | 7 | 1988.52 | 55 | 11.13 | 3200 | 1959 | 2.65 / 425.71 | 2 | 2 |
5 | 13 | 1516.68 | 38 | 12.63 | 2569 | 1233 | 3.88 / 426.94 | 2 | 2 |
6 | 13 | 449.84 | 38 | 13.72 | 1029 | 536 | 4.41 / 427.48 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.39 | 293 | 759 | 5.17 / 428.23 | 2 | 2 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 14.54 | 430 | 181 | 0.18 / 418.14 | 2 | 2 |
2 | 12 | 1120.44 | 6 | 12.31 | 2004 | 148 | 0.33 / 418.29 | 2 | 2 |
3 | 12 | 1992.08 | 10 | 11.14 | 3240 | 361 | 0.69 / 418.65 | 2 | 2 |
4 | 7 | 1990.96 | 55 | 11.16 | 3198 | 1963 | 2.65 / 420.62 | 2 | 2 |
5 | 13 | 1284.72 | 38 | 12.86 | 2250 | 1100 | 3.75 / 421.72 | 2 | 2 |
6 | 13 | 293.76 | 38 | 13.96 | 780 | 414 | 4.17 / 422.13 | 2 | 2 |
7 | 13 | 3.12 | 38 | 14.52 | 297 | 164 | 4.33 / 422.29 | 2 | 2 |
8 | 8 | -0.20 | 180 | 14.34 | 297 | 767 | 5.10 / 423.06 | 2 | 7 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 29 | 14.55 | 432 | 182 | 0.18 / 412.98 | 2 | 2 |
2 | 12 | 1100.60 | 6 | 12.34 | 1968 | 146 | 0.33 / 413.12 | 2 | 2 |
3 | 12 | 1994.28 | 10 | 11.09 | 3208 | 356 | 0.68 / 413.48 | 2 | 2 |
4 | 7 | 1993.24 | 54 | 11.15 | 3186 | 1918 | 2.60 / 415.40 | 2 | 2 |
5 | 13 | 1521.96 | 38 | 12.64 | 2577 | 1238 | 3.84 / 416.64 | 2 | 2 |
6 | 13 | 470.72 | 38 | 13.72 | 1056 | 551 | 4.39 / 417.19 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.38 | 300 | 777 | 5.17 / 417.96 | 2 | 5 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 29 | 14.56 | 441 | 186 | 0.19 / 408.06 | 2 | 2 |
2 | 12 | 1105.28 | 6 | 12.34 | 1978 | 146 | 0.33 / 408.21 | 2 | 2 |
3 | 12 | 1992.84 | 10 | 11.02 | 3218 | 355 | 0.69 / 408.56 | 2 | 2 |
4 | 7 | 1991.60 | 55 | 11.16 | 3190 | 1958 | 2.65 / 410.52 | 2 | 2 |
5 | 13 | 1293.80 | 38 | 12.86 | 2253 | 1101 | 3.75 / 411.62 | 2 | 2 |
6 | 13 | 304.76 | 38 | 13.97 | 793 | 421 | 4.17 / 412.04 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.41 | 291 | 755 | 4.92 / 412.80 | 2 | 4 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 29 | 14.56 | 443 | 187 | 0.19 / 403.06 | 2 | 2 |
2 | 12 | 1107.00 | 6 | 12.30 | 1979 | 146 | 0.33 / 403.21 | 2 | 2 |
3 | 12 | 2000.20 | 10 | 11.10 | 3202 | 355 | 0.69 / 403.56 | 2 | 2 |
4 | 7 | 1999.40 | 54 | 11.19 | 3194 | 1930 | 2.62 / 405.49 | 2 | 2 |
5 | 13 | 1337.24 | 38 | 12.85 | 2322 | 1134 | 3.75 / 406.63 | 2 | 2 |
6 | 13 | 339.60 | 38 | 13.89 | 886 | 468 | 4.22 / 407.10 | 2 | 2 |
7 | 8 | 0.44 | 180 | 14.38 | 301 | 779 | 5.00 / 407.87 | 2 | 3 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 29 | 14.58 | 420 | 178 | 0.18 / 398.04 | 2 | 2 |
2 | 12 | 1101.88 | 6 | 12.37 | 1963 | 146 | 0.32 / 398.19 | 2 | 2 |
3 | 12 | 2000.48 | 10 | 11.03 | 3237 | 357 | 0.68 / 398.55 | 2 | 2 |
4 | 7 | 2000.12 | 55 | 11.22 | 3220 | 1987 | 2.67 / 400.53 | 2 | 2 |
5 | 13 | 1307.92 | 38 | 12.91 | 2273 | 1115 | 3.78 / 401.65 | 2 | 2 |
6 | 13 | 307.40 | 38 | 13.96 | 832 | 441 | 4.22 / 402.09 | 2 | 2 |
7 | 8 | 0.12 | 180 | 14.39 | 303 | 785 | 5.01 / 402.88 | 2 | 2 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 29 | 14.59 | 418 | 177 | 0.18 / 393.04 | 2 | 2 |
2 | 12 | 1109.44 | 6 | 12.31 | 2002 | 148 | 0.32 / 393.18 | 2 | 2 |
3 | 12 | 2001.04 | 10 | 10.92 | 3214 | 351 | 0.68 / 393.54 | 2 | 2 |
4 | 7 | 2000.08 | 53 | 11.22 | 3203 | 1905 | 2.58 / 395.44 | 2 | 2 |
5 | 13 | 1537.52 | 38 | 12.72 | 2598 | 1256 | 3.84 / 396.70 | 2 | 2 |
6 | 13 | 295.64 | 38 | 14.01 | 775 | 413 | 4.25 / 397.11 | 2 | 2 |
7 | 8 | -0.20 | 180 | 14.42 | 292 | 758 | 5.01 / 397.87 | 2 | 2 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 14.58 | 431 | 182 | 0.18 / 387.98 | 2 | 2 |
2 | 12 | 1116.12 | 3 | 10.56 | 1933 | 61 | 0.24 / 388.04 | 2 | 2 |
3 | 12 | 2000.32 | 10 | 10.05 | 3183 | 320 | 0.56 / 388.36 | 2 | 2 |
4 | 7 | 2001.08 | 58 | 11.20 | 3193 | 2074 | 2.64 / 390.44 | 2 | 2 |
5 | 13 | 1531.52 | 37 | 12.74 | 2612 | 1231 | 3.87 / 391.67 | 2 | 2 |
6 | 13 | 308.20 | 37 | 13.98 | 823 | 426 | 4.29 / 392.09 | 2 | 2 |
7 | 8 | -0.16 | 180 | 14.42 | 295 | 766 | 5.06 / 392.86 | 2 | 2 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 29 | 14.58 | 439 | 186 | 0.19 / 382.69 | 2 | 2 |
2 | 12 | 1107.08 | 3 | 10.54 | 1919 | 61 | 0.25 / 382.75 | 2 | 2 |
3 | 12 | 2002.32 | 10 | 9.81 | 3146 | 309 | 0.55 / 383.06 | 2 | 2 |
4 | 7 | 2003.04 | 57 | 11.07 | 3206 | 2023 | 2.58 / 385.09 | 2 | 2 |
5 | 13 | 1513.36 | 37 | 12.75 | 2568 | 1211 | 3.79 / 386.30 | 2 | 2 |
6 | 13 | 500.48 | 37 | 13.74 | 1110 | 564 | 4.35 / 386.86 | 2 | 2 |
7 | 13 | 1.36 | 37 | 14.55 | 300 | 162 | 4.52 / 387.02 | 2 | 2 |
8 | 8 | -0.24 | 180 | 14.34 | 301 | 777 | 5.29 / 387.80 | 2 | 4 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 29 | 14.49 | 422 | 177 | 0.18 / 377.73 | 2 | 2 |
2 | 12 | 1123.36 | 3 | 9.95 | 1928 | 58 | 0.23 / 377.79 | 2 | 2 |
3 | 12 | 2001.92 | 10 | 9.66 | 3156 | 305 | 0.54 / 378.09 | 2 | 2 |
4 | 7 | 2002.80 | 57 | 11.02 | 3210 | 2016 | 2.56 / 380.11 | 2 | 2 |
5 | 13 | 1341.60 | 37 | 12.91 | 2331 | 1113 | 3.67 / 381.22 | 2 | 2 |
6 | 13 | 371.04 | 37 | 13.89 | 931 | 478 | 4.15 / 381.70 | 2 | 2 |
7 | 8 | -0.28 | 180 | 14.38 | 312 | 808 | 4.96 / 382.51 | 2 | 2 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 29 | 14.58 | 424 | 179 | 0.18 / 372.62 | 2 | 2 |
2 | 12 | 1102.04 | 3 | 10.31 | 1913 | 59 | 0.24 / 372.68 | 2 | 2 |
3 | 12 | 2003.88 | 10 | 10.09 | 3191 | 322 | 0.56 / 373.01 | 2 | 2 |
4 | 7 | 2004.08 | 57 | 11.11 | 3222 | 2040 | 2.60 / 375.05 | 2 | 2 |
5 | 13 | 1319.92 | 37 | 12.93 | 2321 | 1110 | 3.71 / 376.16 | 2 | 2 |
6 | 13 | 360.28 | 37 | 13.92 | 911 | 469 | 4.18 / 376.63 | 2 | 2 |
7 | 13 | 3.28 | 37 | 14.55 | 300 | 162 | 4.34 / 376.79 | 2 | 2 |
8 | 8 | -0.16 | 180 | 14.36 | 296 | 765 | 5.11 / 377.55 | 2 | 8 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 29 | 14.57 | 439 | 185 | 0.19 / 367.42 | 2 | 2 |
2 | 12 | 1114.56 | 3 | 10.27 | 1934 | 60 | 0.25 / 367.48 | 2 | 2 |
3 | 12 | 2005.28 | 10 | 9.95 | 3193 | 318 | 0.56 / 367.80 | 2 | 2 |
4 | 7 | 2006.00 | 58 | 11.18 | 3222 | 2089 | 2.65 / 369.88 | 2 | 2 |
5 | 13 | 1525.20 | 37 | 12.77 | 2595 | 1226 | 3.88 / 371.11 | 2 | 2 |
6 | 13 | 485.84 | 37 | 13.76 | 1095 | 557 | 4.44 / 371.67 | 2 | 2 |
7 | 8 | -0.12 | 180 | 14.39 | 300 | 777 | 5.21 / 372.45 | 2 | 2 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 29 | 14.60 | 437 | 185 | 0.19 / 362.14 | 2 | 2 |
2 | 7 | 2007.60 | 57 | 10.98 | 3177 | 1988 | 2.17 / 364.13 | 2 | 2 |
3 | 13 | 1786.20 | 37 | 12.56 | 2936 | 1364 | 3.54 / 365.49 | 2 | 2 |
4 | 13 | 775.36 | 37 | 13.46 | 1537 | 765 | 4.30 / 366.26 | 2 | 2 |
5 | 13 | 22.40 | 37 | 14.51 | 342 | 184 | 4.49 / 366.44 | 2 | 2 |
6 | 8 | -0.28 | 180 | 14.38 | 306 | 792 | 5.28 / 367.23 | 2 | 3 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 28 | 14.51 | 427 | 173 | 0.17 / 356.94 | 2 | 2 |
2 | 7 | 2007.08 | 57 | 10.77 | 3192 | 1960 | 2.13 / 358.90 | 2 | 2 |
3 | 13 | 1803.44 | 37 | 12.53 | 2969 | 1376 | 3.51 / 360.27 | 2 | 2 |
4 | 13 | 765.52 | 37 | 13.49 | 1500 | 749 | 4.26 / 361.02 | 2 | 2 |
5 | 13 | 25.36 | 37 | 14.53 | 328 | 176 | 4.43 / 361.20 | 2 | 2 |
6 | 8 | -0.24 | 180 | 14.40 | 292 | 757 | 5.19 / 361.95 | 2 | 8 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 28 | 14.60 | 431 | 176 | 0.18 / 351.68 | 2 | 2 |
2 | 7 | 2006.64 | 57 | 11.01 | 3185 | 1999 | 2.18 / 353.68 | 2 | 2 |
3 | 13 | 1785.08 | 37 | 12.59 | 2938 | 1369 | 3.54 / 355.05 | 2 | 2 |
4 | 13 | 774.60 | 37 | 13.49 | 1522 | 760 | 4.30 / 355.81 | 2 | 2 |
5 | 13 | 8.44 | 37 | 14.55 | 312 | 168 | 4.47 / 355.98 | 2 | 2 |
6 | 8 | -0.16 | 180 | 14.36 | 304 | 786 | 5.26 / 356.76 | 2 | 2 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 28 | 14.61 | 440 | 180 | 0.18 / 346.37 | 2 | 2 |
2 | 7 | 2001.76 | 57 | 11.03 | 3201 | 2013 | 2.19 / 348.38 | 2 | 2 |
3 | 13 | 1793.08 | 37 | 12.57 | 2949 | 1372 | 3.56 / 349.75 | 2 | 2 |
4 | 13 | 776.24 | 37 | 13.48 | 1538 | 767 | 4.33 / 350.52 | 2 | 2 |
5 | 13 | 51.44 | 37 | 14.47 | 383 | 205 | 4.54 / 350.72 | 2 | 2 |
6 | 8 | -0.24 | 180 | 14.38 | 302 | 782 | 5.32 / 351.51 | 2 | 3 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 28 | 14.56 | 406 | 166 | 0.17 / 341.54 | 2 | 2 |
2 | 7 | 2003.96 | 57 | 10.87 | 3172 | 1965 | 2.13 / 343.50 | 2 | 2 |
3 | 13 | 1588.48 | 37 | 12.77 | 2690 | 1271 | 3.40 / 344.78 | 2 | 2 |
4 | 13 | 630.24 | 37 | 13.67 | 1299 | 657 | 4.06 / 345.43 | 2 | 2 |
5 | 8 | 0.60 | 180 | 14.42 | 291 | 755 | 4.81 / 346.19 | 2 | 2 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 28 | 14.62 | 441 | 181 | 0.18 / 336.64 | 2 | 2 |
2 | 7 | 2003.04 | 46 | 11.13 | 3188 | 1632 | 1.81 / 338.27 | 2 | 2 |
3 | 13 | 1802.60 | 42 | 12.52 | 2958 | 1555 | 3.37 / 339.83 | 2 | 2 |
4 | 13 | 627.40 | 42 | 13.64 | 1292 | 740 | 4.11 / 340.57 | 2 | 2 |
5 | 8 | 0.56 | 190 | 14.40 | 295 | 807 | 4.92 / 341.37 | 2 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 14.63 | 438 | 179 | 0.18 / 331.91 | 2 | 2 |
2 | 7 | 2004.84 | 46 | 11.17 | 3214 | 1651 | 1.83 / 333.56 | 2 | 2 |
3 | 13 | 1607.40 | 42 | 12.70 | 2715 | 1448 | 3.28 / 335.01 | 2 | 2 |
4 | 13 | 482.24 | 42 | 13.80 | 1082 | 627 | 3.91 / 335.64 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.41 | 299 | 819 | 4.72 / 336.46 | 2 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 28 | 14.62 | 445 | 182 | 0.18 / 326.95 | 2 | 2 |
2 | 7 | 2007.36 | 46 | 11.22 | 3204 | 1654 | 1.84 / 328.61 | 2 | 2 |
3 | 13 | 1809.00 | 42 | 12.55 | 2968 | 1564 | 3.40 / 330.17 | 2 | 2 |
4 | 13 | 609.36 | 42 | 13.65 | 1284 | 736 | 4.14 / 330.91 | 2 | 2 |
5 | 8 | -0.04 | 190 | 14.41 | 302 | 827 | 4.96 / 331.73 | 2 | 3 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 28 | 14.59 | 438 | 179 | 0.18 / 321.98 | 2 | 2 |
2 | 7 | 2003.64 | 46 | 11.15 | 3202 | 1642 | 1.82 / 323.62 | 2 | 2 |
3 | 13 | 1821.96 | 42 | 12.54 | 2983 | 1571 | 3.39 / 325.19 | 2 | 2 |
4 | 13 | 621.92 | 42 | 13.67 | 1286 | 738 | 4.13 / 325.93 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.40 | 308 | 843 | 4.97 / 326.77 | 2 | 3 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 28 | 14.65 | 448 | 184 | 0.18 / 317.02 | 2 | 2 |
2 | 7 | 2003.36 | 46 | 11.34 | 3222 | 1681 | 1.86 / 318.70 | 2 | 2 |
3 | 13 | 1615.92 | 42 | 12.76 | 2723 | 1459 | 3.32 / 320.16 | 2 | 2 |
4 | 13 | 668.20 | 42 | 13.63 | 1363 | 780 | 4.10 / 320.94 | 2 | 2 |
5 | 8 | -0.12 | 190 | 14.38 | 315 | 861 | 4.96 / 321.80 | 2 | 3 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 28 | 14.65 | 420 | 172 | 0.17 / 312.15 | 2 | 2 |
2 | 7 | 2002.04 | 46 | 11.29 | 3211 | 1668 | 1.84 / 313.81 | 2 | 2 |
3 | 13 | 1592.96 | 42 | 12.79 | 2667 | 1433 | 3.27 / 315.25 | 2 | 2 |
4 | 13 | 642.44 | 42 | 13.67 | 1317 | 756 | 4.03 / 316.00 | 2 | 2 |
5 | 8 | -0.20 | 190 | 14.42 | 303 | 830 | 4.86 / 316.83 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 28 | 14.64 | 420 | 172 | 0.17 / 307.35 | 2 | 2 |
2 | 7 | 2007.96 | 46 | 11.34 | 3240 | 1690 | 1.86 / 309.04 | 2 | 2 |
3 | 13 | 1625.92 | 42 | 12.79 | 2725 | 1464 | 3.33 / 310.51 | 2 | 2 |
4 | 13 | 474.52 | 42 | 13.83 | 1094 | 635 | 3.96 / 311.14 | 2 | 2 |
5 | 8 | -0.24 | 190 | 14.41 | 303 | 830 | 4.79 / 311.97 | 2 | 4 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 28 | 14.68 | 431 | 177 | 0.18 / 302.61 | 2 | 2 |
2 | 7 | 2003.40 | 46 | 11.72 | 3217 | 1734 | 1.91 / 304.34 | 2 | 2 |
3 | 13 | 1593.36 | 42 | 12.85 | 2676 | 1444 | 3.36 / 305.79 | 2 | 2 |
4 | 13 | 447.04 | 42 | 13.89 | 1022 | 596 | 3.95 / 306.38 | 2 | 2 |
5 | 8 | -0.08 | 190 | 14.44 | 291 | 798 | 4.75 / 307.18 | 2 | 2 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 28 | 14.68 | 428 | 176 | 0.18 / 297.78 | 2 | 2 |
2 | 7 | 2004.40 | 46 | 11.80 | 3221 | 1748 | 1.92 / 299.53 | 2 | 2 |
3 | 13 | 1616.24 | 42 | 12.83 | 2742 | 1478 | 3.40 / 301.01 | 2 | 2 |
4 | 13 | 443.88 | 42 | 13.89 | 1031 | 601 | 4.00 / 301.61 | 2 | 2 |
5 | 8 | -0.20 | 190 | 14.43 | 299 | 820 | 4.82 / 302.43 | 2 | 3 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 27 | 14.72 | 422 | 168 | 0.17 / 292.97 | 2 | 2 |
2 | 3 | 1036.92 | 1 | 13.25 | 1910 | 25 | 0.19 / 292.99 | 2 | 2 |
3 | 7 | 2003.36 | 46 | 11.84 | 3231 | 1760 | 1.95 / 294.75 | 2 | 2 |
4 | 13 | 1610.04 | 42 | 12.86 | 2709 | 1463 | 3.42 / 296.22 | 2 | 2 |
5 | 13 | 438.68 | 42 | 13.91 | 1011 | 591 | 4.01 / 296.81 | 2 | 2 |
6 | 8 | -0.04 | 190 | 14.44 | 292 | 801 | 4.81 / 297.61 | 2 | 2 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 28 | 14.68 | 431 | 177 | 0.18 / 288.15 | 2 | 2 |
2 | 3 | 971.76 | -1 | 14.68 | 431 | 0 | 0.00 / 288.15 | 2 | 2 |
3 | 7 | 2005.12 | 46 | 11.92 | 3230 | 1771 | 1.95 / 289.92 | 2 | 2 |
4 | 13 | 1614.80 | 42 | 12.89 | 2695 | 1459 | 3.41 / 291.38 | 2 | 2 |
5 | 13 | 450.36 | 42 | 13.89 | 1035 | 604 | 4.01 / 291.99 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.43 | 297 | 814 | 4.83 / 292.80 | 2 | 3 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 28 | 14.69 | 444 | 183 | 0.18 / 283.27 | 2 | 2 |
2 | 7 | 2002.44 | 47 | 11.97 | 3219 | 1811 | 1.99 / 285.08 | 2 | 2 |
3 | 13 | 1605.12 | 42 | 12.90 | 2710 | 1468 | 3.46 / 286.54 | 2 | 2 |
4 | 13 | 441.04 | 42 | 13.91 | 1018 | 595 | 4.06 / 287.14 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.43 | 305 | 836 | 4.89 / 287.98 | 2 | 2 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 28 | 14.74 | 417 | 172 | 0.17 / 278.40 | 2 | 2 |
2 | 7 | 2004.08 | 46 | 11.97 | 3196 | 1760 | 1.93 / 280.16 | 2 | 2 |
3 | 13 | 1619.72 | 42 | 12.93 | 2676 | 1453 | 3.39 / 281.62 | 2 | 2 |
4 | 13 | 453.08 | 42 | 13.90 | 1040 | 607 | 3.99 / 282.22 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.42 | 313 | 858 | 4.85 / 283.08 | 2 | 2 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 28 | 14.71 | 435 | 179 | 0.18 / 273.24 | 2 | 2 |
2 | 7 | 2012.04 | 47 | 12.07 | 3259 | 1849 | 2.03 / 275.09 | 2 | 2 |
3 | 13 | 1830.52 | 42 | 12.76 | 3013 | 1615 | 3.64 / 276.70 | 2 | 2 |
4 | 13 | 573.00 | 42 | 13.78 | 1228 | 711 | 4.35 / 277.41 | 2 | 2 |
5 | 8 | 0.56 | 190 | 14.41 | 300 | 821 | 5.17 / 278.23 | 2 | 3 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 14.69 | 404 | 166 | 0.17 / 268.17 | 2 | 2 |
2 | 7 | 2003.64 | 46 | 12.09 | 3256 | 1811 | 1.98 / 269.98 | 2 | 2 |
3 | 13 | 1598.08 | 42 | 12.94 | 2702 | 1468 | 3.45 / 271.45 | 2 | 2 |
4 | 13 | 431.08 | 42 | 13.93 | 1019 | 596 | 4.04 / 272.04 | 2 | 2 |
5 | 13 | 6.36 | 42 | 14.58 | 307 | 188 | 4.23 / 272.23 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.38 | 302 | 825 | 5.05 / 273.06 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 28 | 14.74 | 422 | 174 | 0.17 / 263.27 | 2 | 2 |
2 | 7 | 2001.20 | 47 | 12.25 | 3227 | 1858 | 2.03 / 265.12 | 2 | 2 |
3 | 13 | 1590.80 | 42 | 12.94 | 2703 | 1469 | 3.50 / 266.59 | 2 | 2 |
4 | 13 | 415.16 | 42 | 13.94 | 1002 | 587 | 4.09 / 267.18 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.44 | 300 | 823 | 4.91 / 268.00 | 2 | 3 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 28 | 14.73 | 443 | 183 | 0.18 / 258.19 | 2 | 2 |
2 | 7 | 2005.24 | 46 | 12.28 | 3249 | 1835 | 2.02 / 260.02 | 2 | 2 |
3 | 13 | 1594.76 | 42 | 12.95 | 2693 | 1465 | 3.48 / 261.49 | 2 | 2 |
4 | 13 | 409.76 | 42 | 13.95 | 988 | 579 | 4.06 / 262.07 | 2 | 2 |
5 | 13 | 8.00 | 42 | 14.56 | 314 | 192 | 4.25 / 262.26 | 2 | 2 |
6 | 8 | -0.32 | 190 | 14.36 | 306 | 835 | 5.09 / 263.09 | 2 | 13 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 14.75 | 422 | 174 | 0.17 / 253.29 | 2 | 2 |
2 | 7 | 2003.80 | 46 | 12.29 | 3241 | 1832 | 2.01 / 255.13 | 2 | 2 |
3 | 13 | 1611.88 | 42 | 12.94 | 2714 | 1475 | 3.48 / 256.60 | 2 | 2 |
4 | 13 | 418.56 | 42 | 13.94 | 992 | 581 | 4.06 / 257.18 | 2 | 2 |
5 | 8 | -0.32 | 190 | 14.43 | 300 | 823 | 4.88 / 258.00 | 2 | 2 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 28 | 14.74 | 436 | 180 | 0.18 / 248.25 | 2 | 2 |
2 | 7 | 2002.96 | 46 | 12.28 | 3243 | 1832 | 2.01 / 250.08 | 2 | 2 |
3 | 13 | 1583.96 | 42 | 12.96 | 2675 | 1456 | 3.47 / 251.54 | 2 | 2 |
4 | 13 | 394.48 | 42 | 13.96 | 955 | 560 | 4.03 / 252.10 | 2 | 2 |
5 | 13 | 7.28 | 42 | 14.57 | 309 | 189 | 4.22 / 252.29 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.37 | 305 | 833 | 5.05 / 253.12 | 2 | 15 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 28 | 14.78 | 411 | 170 | 0.17 / 243.37 | 2 | 2 |
2 | 7 | 2001.64 | 46 | 12.22 | 3249 | 1826 | 2.00 / 245.20 | 2 | 2 |
3 | 13 | 1599.72 | 42 | 12.94 | 2693 | 1464 | 3.46 / 246.66 | 2 | 2 |
4 | 13 | 429.12 | 42 | 13.92 | 1010 | 590 | 4.05 / 247.25 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.43 | 298 | 817 | 4.87 / 248.07 | 2 | 2 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 27 | 14.77 | 428 | 171 | 0.17 / 238.48 | 2 | 2 |
2 | 7 | 2006.04 | 46 | 12.26 | 3246 | 1831 | 2.00 / 240.31 | 2 | 2 |
3 | 13 | 1616.40 | 42 | 12.92 | 2738 | 1486 | 3.49 / 241.79 | 2 | 2 |
4 | 13 | 429.80 | 42 | 13.94 | 1003 | 587 | 4.07 / 242.38 | 2 | 2 |
5 | 8 | -0.32 | 190 | 14.44 | 299 | 820 | 4.89 / 243.20 | 2 | 2 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 27 | 14.78 | 417 | 166 | 0.17 / 233.76 | 2 | 2 |
2 | 7 | 2004.64 | 46 | 12.18 | 3237 | 1814 | 1.98 / 235.57 | 2 | 2 |
3 | 13 | 1570.56 | 39 | 13.01 | 2659 | 1349 | 3.33 / 236.92 | 2 | 2 |
4 | 13 | 420.20 | 39 | 13.95 | 1010 | 549 | 3.88 / 237.47 | 2 | 2 |
5 | 8 | -0.48 | 190 | 14.43 | 305 | 836 | 4.71 / 238.31 | 2 | 3 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 27 | 14.76 | 424 | 169 | 0.17 / 228.85 | 2 | 2 |
2 | 7 | 2006.68 | 46 | 12.20 | 3231 | 1813 | 1.98 / 230.66 | 2 | 2 |
3 | 13 | 1599.12 | 39 | 12.98 | 2707 | 1370 | 3.35 / 232.03 | 2 | 2 |
4 | 13 | 431.64 | 39 | 13.96 | 1006 | 548 | 3.90 / 232.58 | 2 | 2 |
5 | 13 | 14.84 | 39 | 14.58 | 324 | 184 | 4.08 / 232.76 | 2 | 2 |
6 | 8 | -0.44 | 190 | 14.38 | 303 | 828 | 4.91 / 233.59 | 2 | 9 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 27 | 14.75 | 428 | 170 | 0.17 / 223.87 | 2 | 2 |
2 | 7 | 2016.84 | 51 | 12.20 | 3255 | 2025 | 2.20 / 225.89 | 2 | 2 |
3 | 13 | 1578.84 | 37 | 13.01 | 2669 | 1285 | 3.48 / 227.18 | 2 | 2 |
4 | 13 | 389.80 | 37 | 14.01 | 958 | 497 | 3.98 / 227.67 | 2 | 2 |
5 | 13 | 28.32 | 37 | 14.58 | 340 | 183 | 4.16 / 227.86 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.39 | 301 | 823 | 4.98 / 228.68 | 2 | 5 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 27 | 14.76 | 424 | 169 | 0.17 / 219.02 | 2 | 2 |
2 | 7 | 2003.08 | 50 | 12.25 | 3247 | 1989 | 2.16 / 221.00 | 2 | 2 |
3 | 13 | 1352.12 | 37 | 13.17 | 2358 | 1149 | 3.31 / 222.15 | 2 | 2 |
4 | 13 | 430.04 | 37 | 13.97 | 1009 | 522 | 3.83 / 222.67 | 2 | 2 |
5 | 13 | 27.92 | 37 | 14.56 | 351 | 189 | 4.02 / 222.86 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.37 | 305 | 833 | 4.85 / 223.70 | 2 | 7 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 27 | 14.74 | 443 | 176 | 0.18 / 214.13 | 2 | 2 |
2 | 7 | 2003.00 | 51 | 12.33 | 3222 | 2026 | 2.20 / 216.15 | 2 | 2 |
3 | 13 | 1553.64 | 36 | 13.08 | 2624 | 1236 | 3.44 / 217.39 | 2 | 2 |
4 | 13 | 384.76 | 36 | 14.05 | 933 | 472 | 3.91 / 217.86 | 2 | 2 |
5 | 13 | 25.24 | 36 | 14.60 | 332 | 174 | 4.08 / 218.04 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.40 | 296 | 810 | 4.89 / 218.85 | 2 | 9 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 27 | 14.75 | 436 | 174 | 0.17 / 209.96 | 2 | 2 |
2 | 7 | 1502.60 | 50 | 12.61 | 2564 | 1617 | 1.79 / 211.58 | 2 | 2 |
3 | 13 | 1310.56 | 36 | 13.15 | 2320 | 1098 | 2.89 / 212.68 | 2 | 2 |
4 | 13 | 357.40 | 36 | 14.06 | 894 | 453 | 3.34 / 213.13 | 2 | 2 |
5 | 8 | -0.32 | 190 | 14.45 | 299 | 821 | 4.16 / 213.95 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 27 | 14.76 | 429 | 171 | 0.17 / 204.90 | 2 | 2 |
2 | 7 | 2002.72 | 51 | 12.36 | 3249 | 2048 | 2.22 / 206.95 | 2 | 2 |
3 | 13 | 1586.72 | 36 | 13.06 | 2680 | 1260 | 3.48 / 208.21 | 2 | 2 |
4 | 13 | 429.68 | 36 | 14.00 | 1011 | 510 | 3.99 / 208.72 | 2 | 2 |
5 | 13 | 35.16 | 36 | 14.57 | 380 | 199 | 4.19 / 208.92 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.38 | 319 | 872 | 5.06 / 209.79 | 2 | 5 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 27 | 14.76 | 426 | 170 | 0.17 / 200.16 | 2 | 2 |
2 | 7 | 2002.80 | 51 | 12.36 | 3248 | 2047 | 2.22 / 202.21 | 2 | 2 |
3 | 13 | 1386.08 | 36 | 13.17 | 2414 | 1145 | 3.36 / 203.35 | 2 | 2 |
4 | 13 | 461.64 | 36 | 13.94 | 1084 | 544 | 3.91 / 203.90 | 2 | 2 |
5 | 8 | -0.24 | 190 | 14.46 | 304 | 835 | 4.74 / 204.73 | 2 | 4 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 27 | 14.76 | 441 | 176 | 0.18 / 194.89 | 2 | 2 |
2 | 7 | 2006.12 | 51 | 12.38 | 3240 | 2046 | 2.22 / 196.94 | 2 | 2 |
3 | 13 | 1806.52 | 36 | 12.89 | 3004 | 1394 | 3.62 / 198.33 | 2 | 2 |
4 | 13 | 582.68 | 36 | 13.85 | 1239 | 618 | 4.23 / 198.95 | 2 | 2 |
5 | 13 | 59.12 | 36 | 14.56 | 400 | 210 | 4.44 / 199.16 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.41 | 304 | 832 | 5.28 / 199.99 | 2 | 6 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 27 | 14.79 | 433 | 173 | 0.17 / 190.24 | 2 | 2 |
2 | 7 | 2006.56 | 50 | 12.42 | 3243 | 2014 | 2.19 / 192.26 | 2 | 2 |
3 | 13 | 1351.52 | 36 | 13.23 | 2356 | 1122 | 3.31 / 193.38 | 2 | 2 |
4 | 13 | 433.84 | 36 | 14.02 | 1007 | 508 | 3.82 / 193.89 | 2 | 2 |
5 | 8 | -0.20 | 190 | 14.46 | 301 | 827 | 4.64 / 194.71 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 27 | 14.77 | 444 | 177 | 0.18 / 185.91 | 2 | 2 |
2 | 7 | 1556.52 | 51 | 12.68 | 2620 | 1694 | 1.87 / 187.61 | 2 | 2 |
3 | 13 | 1397.24 | 36 | 13.12 | 2410 | 1138 | 3.01 / 188.75 | 2 | 2 |
4 | 13 | 398.00 | 36 | 14.03 | 961 | 485 | 3.50 / 189.23 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.45 | 305 | 837 | 4.33 / 190.07 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 27 | 14.75 | 435 | 173 | 0.17 / 181.53 | 2 | 2 |
2 | 7 | 1799.36 | 50 | 12.59 | 2955 | 1860 | 2.03 / 183.39 | 2 | 2 |
3 | 13 | 1384.68 | 36 | 13.20 | 2402 | 1141 | 3.17 / 184.53 | 2 | 2 |
4 | 13 | 275.44 | 36 | 14.24 | 774 | 397 | 3.57 / 184.93 | 2 | 2 |
5 | 8 | -0.08 | 190 | 14.50 | 295 | 813 | 4.38 / 185.74 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 27 | 14.77 | 418 | 167 | 0.17 / 177.31 | 2 | 2 |
2 | 7 | 1602.76 | 51 | 12.67 | 2678 | 1730 | 1.90 / 179.04 | 2 | 2 |
3 | 13 | 1249.60 | 36 | 13.28 | 2215 | 1059 | 2.96 / 180.10 | 2 | 2 |
4 | 13 | 340.20 | 36 | 14.15 | 852 | 434 | 3.39 / 180.53 | 2 | 2 |
5 | 8 | 0.16 | 190 | 14.45 | 300 | 824 | 4.21 / 181.35 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 27 | 14.77 | 430 | 171 | 0.17 / 173.06 | 2 | 2 |
2 | 7 | 1757.76 | 51 | 12.66 | 2901 | 1873 | 2.04 / 174.94 | 2 | 2 |
3 | 13 | 1159.56 | 36 | 13.38 | 2080 | 1002 | 3.05 / 175.94 | 2 | 2 |
4 | 13 | 271.36 | 36 | 14.27 | 737 | 379 | 3.43 / 176.32 | 2 | 2 |
5 | 8 | -0.12 | 190 | 14.47 | 299 | 822 | 4.25 / 177.14 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 14.77 | 435 | 173 | 0.17 / 169.31 | 2 | 2 |
2 | 7 | 1344.88 | 51 | 12.93 | 2334 | 1539 | 1.71 / 170.85 | 2 | 2 |
3 | 13 | 993.48 | 36 | 13.46 | 1866 | 904 | 2.62 / 171.75 | 2 | 2 |
4 | 13 | 182.08 | 36 | 14.39 | 612 | 317 | 2.93 / 172.07 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.49 | 299 | 823 | 3.76 / 172.89 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 27 | 14.75 | 457 | 182 | 0.18 / 165.16 | 2 | 2 |
2 | 7 | 1485.60 | 50 | 12.85 | 2545 | 1635 | 1.82 / 166.79 | 2 | 2 |
3 | 13 | 1298.68 | 36 | 13.25 | 2301 | 1098 | 2.91 / 167.89 | 2 | 2 |
4 | 13 | 302.12 | 36 | 14.20 | 807 | 413 | 3.33 / 168.30 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.46 | 303 | 832 | 4.16 / 169.14 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 27 | 14.77 | 442 | 176 | 0.18 / 161.37 | 2 | 2 |
2 | 7 | 1245.44 | 51 | 13.02 | 2187 | 1452 | 1.63 / 162.82 | 2 | 2 |
3 | 13 | 1088.16 | 36 | 13.39 | 1976 | 953 | 2.58 / 163.78 | 2 | 2 |
4 | 13 | 214.84 | 36 | 14.33 | 675 | 348 | 2.93 / 164.12 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.47 | 310 | 852 | 3.78 / 164.98 | 2 | 2 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 27 | 14.79 | 434 | 173 | 0.17 / 157.67 | 2 | 2 |
2 | 7 | 1243.72 | 51 | 13.11 | 2172 | 1452 | 1.63 / 159.13 | 2 | 2 |
3 | 13 | 1064.44 | 36 | 13.43 | 1950 | 943 | 2.57 / 160.07 | 2 | 3 |
4 | 13 | 174.68 | 36 | 14.41 | 594 | 308 | 2.88 / 160.38 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.50 | 297 | 818 | 3.69 / 161.19 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 27 | 14.79 | 430 | 172 | 0.17 / 153.49 | 2 | 2 |
2 | 7 | 1585.68 | 51 | 12.92 | 2674 | 1762 | 1.93 / 155.25 | 2 | 2 |
3 | 13 | 1207.84 | 36 | 13.39 | 2150 | 1036 | 2.97 / 156.29 | 2 | 2 |
4 | 13 | 267.20 | 36 | 14.27 | 758 | 389 | 3.36 / 156.68 | 2 | 2 |
5 | 8 | -0.16 | 190 | 14.49 | 298 | 820 | 4.18 / 157.50 | 2 | 5 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 27 | 14.79 | 434 | 173 | 0.17 / 149.50 | 2 | 2 |
2 | 7 | 1408.64 | 50 | 13.04 | 2425 | 1581 | 1.75 / 151.08 | 2 | 2 |
3 | 13 | 1216.88 | 36 | 13.36 | 2174 | 1046 | 2.80 / 152.13 | 2 | 2 |
4 | 13 | 276.88 | 36 | 14.27 | 755 | 388 | 3.19 / 152.51 | 2 | 2 |
5 | 8 | -0.24 | 190 | 14.48 | 293 | 806 | 3.99 / 153.32 | 2 | 2 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 27 | 14.79 | 426 | 170 | 0.17 / 145.72 | 2 | 2 |
2 | 3 | 967.16 | -1 | 14.79 | 426 | 0 | 0.00 / 145.72 | 2 | 2 |
3 | 3 | 1052.60 | 1 | 14.04 | 1976 | 28 | 0.20 / 145.74 | 2 | 2 |
4 | 7 | 1272.88 | 51 | 13.06 | 2259 | 1505 | 1.70 / 147.25 | 2 | 2 |
5 | 13 | 1085.92 | 36 | 13.43 | 1979 | 957 | 2.66 / 148.20 | 2 | 2 |
6 | 13 | 187.84 | 36 | 14.40 | 606 | 314 | 2.97 / 148.52 | 2 | 2 |
7 | 8 | -0.12 | 190 | 14.50 | 293 | 807 | 3.78 / 149.33 | 2 | 4 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 27 | 14.77 | 434 | 173 | 0.17 / 141.88 | 2 | 2 |
2 | 7 | 1321.64 | 51 | 13.16 | 2307 | 1548 | 1.72 / 143.43 | 2 | 2 |
3 | 13 | 1133.28 | 36 | 13.44 | 2044 | 989 | 2.71 / 144.42 | 2 | 2 |
4 | 13 | 197.04 | 36 | 14.40 | 616 | 319 | 3.03 / 144.74 | 2 | 2 |
5 | 8 | -0.12 | 190 | 14.50 | 293 | 807 | 3.84 / 145.55 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 27 | 14.79 | 430 | 172 | 0.17 / 137.77 | 2 | 2 |
2 | 3 | 961.88 | -1 | 14.79 | 430 | 0 | 0.00 / 137.77 | 2 | 2 |
3 | 3 | 1053.40 | 1 | 14.15 | 1975 | 28 | 0.20 / 137.80 | 2 | 2 |
4 | 7 | 1461.56 | 50 | 13.04 | 2506 | 1634 | 1.83 / 139.44 | 2 | 2 |
5 | 13 | 1272.36 | 36 | 13.34 | 2243 | 1077 | 2.91 / 140.51 | 2 | 2 |
6 | 13 | 260.68 | 36 | 14.30 | 728 | 375 | 3.29 / 140.89 | 2 | 2 |
7 | 8 | -0.32 | 190 | 14.48 | 298 | 820 | 4.11 / 141.71 | 2 | 2 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 26 | 14.83 | 424 | 163 | 0.16 / 133.54 | 2 | 2 |
2 | 3 | 965.16 | -1 | 14.83 | 424 | 0 | 0.00 / 133.54 | 2 | 2 |
3 | 3 | 1083.80 | 2 | 14.19 | 2012 | 57 | 0.22 / 133.60 | 2 | 2 |
4 | 7 | 1600.00 | 50 | 13.01 | 2691 | 1750 | 1.97 / 135.35 | 2 | 2 |
5 | 13 | 1209.16 | 36 | 13.41 | 2156 | 1041 | 3.01 / 136.39 | 2 | 2 |
6 | 13 | 251.96 | 36 | 14.30 | 746 | 384 | 3.40 / 136.77 | 2 | 2 |
7 | 8 | -0.20 | 190 | 14.48 | 302 | 831 | 4.23 / 137.60 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 26 | 14.84 | 432 | 167 | 0.17 / 129.45 | 2 | 2 |
2 | 7 | 1668.48 | 51 | 12.98 | 2801 | 1854 | 2.02 / 131.30 | 2 | 2 |
3 | 13 | 1036.84 | 36 | 13.53 | 1927 | 939 | 2.96 / 132.24 | 2 | 2 |
4 | 13 | 185.16 | 36 | 14.42 | 609 | 316 | 3.28 / 132.56 | 2 | 2 |
5 | 8 | -0.24 | 190 | 14.50 | 297 | 818 | 4.09 / 133.38 | 2 | 2 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 26 | 14.83 | 449 | 173 | 0.17 / 124.91 | 2 | 2 |
2 | 7 | 2005.88 | 50 | 12.81 | 3279 | 2100 | 2.27 / 127.01 | 2 | 2 |
3 | 13 | 1197.52 | 36 | 13.44 | 2164 | 1047 | 3.32 / 128.06 | 2 | 2 |
4 | 13 | 275.28 | 36 | 14.29 | 776 | 399 | 3.72 / 128.46 | 2 | 2 |
5 | 8 | -0.12 | 190 | 14.52 | 298 | 822 | 4.54 / 129.28 | 2 | 3 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 26 | 14.85 | 435 | 168 | 0.17 / 119.99 | 2 | 2 |
2 | 7 | 2004.64 | 50 | 12.74 | 3254 | 2073 | 2.24 / 122.06 | 2 | 2 |
3 | 13 | 1369.76 | 36 | 13.31 | 2409 | 1154 | 3.40 / 123.21 | 2 | 2 |
4 | 13 | 416.76 | 36 | 14.11 | 996 | 506 | 3.90 / 123.72 | 2 | 2 |
5 | 13 | 15.12 | 36 | 14.68 | 335 | 177 | 4.08 / 123.90 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.41 | 308 | 843 | 4.92 / 124.74 | 2 | 5 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 26 | 14.85 | 437 | 169 | 0.17 / 115.05 | 2 | 2 |
2 | 7 | 2004.56 | 50 | 12.80 | 3249 | 2079 | 2.25 / 117.13 | 2 | 2 |
3 | 13 | 1394.40 | 36 | 13.31 | 2448 | 1173 | 3.42 / 118.31 | 2 | 2 |
4 | 13 | 430.80 | 36 | 14.10 | 1017 | 516 | 3.94 / 118.82 | 2 | 2 |
5 | 13 | 14.20 | 36 | 14.70 | 322 | 170 | 4.11 / 118.99 | 2 | 2 |
6 | 8 | -0.32 | 190 | 14.42 | 302 | 827 | 4.94 / 119.82 | 2 | 11 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 26 | 14.88 | 409 | 158 | 0.16 / 110.46 | 2 | 2 |
2 | 7 | 2006.88 | 50 | 12.78 | 3252 | 2078 | 2.24 / 112.54 | 2 | 2 |
3 | 13 | 1382.72 | 36 | 13.33 | 2410 | 1157 | 3.39 / 113.69 | 2 | 2 |
4 | 13 | 266.04 | 36 | 14.32 | 735 | 379 | 3.77 / 114.07 | 2 | 2 |
5 | 8 | -0.32 | 190 | 14.52 | 294 | 811 | 4.58 / 114.88 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 26 | 14.86 | 422 | 163 | 0.16 / 106.04 | 2 | 2 |
2 | 7 | 2003.56 | 50 | 12.81 | 3237 | 2073 | 2.24 / 108.11 | 2 | 2 |
3 | 13 | 1162.32 | 36 | 13.48 | 2085 | 1012 | 3.25 / 109.12 | 2 | 3 |
4 | 13 | 278.24 | 36 | 14.29 | 757 | 389 | 3.64 / 109.51 | 2 | 2 |
5 | 8 | -0.20 | 190 | 14.52 | 286 | 789 | 4.43 / 110.30 | 2 | 2 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 26 | 14.89 | 421 | 163 | 0.16 / 101.29 | 2 | 2 |
2 | 7 | 2002.76 | 51 | 12.82 | 3236 | 2116 | 2.28 / 103.40 | 2 | 2 |
3 | 13 | 1370.48 | 36 | 13.35 | 2379 | 1143 | 3.42 / 104.55 | 2 | 2 |
4 | 13 | 428.84 | 36 | 14.10 | 1017 | 516 | 3.94 / 105.06 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.48 | 295 | 812 | 4.75 / 105.87 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 26 | 14.87 | 437 | 169 | 0.17 / 96.55 | 2 | 2 |
2 | 7 | 2007.24 | 50 | 12.84 | 3262 | 2094 | 2.26 / 98.64 | 2 | 2 |
3 | 13 | 1360.68 | 36 | 13.36 | 2368 | 1139 | 3.40 / 99.78 | 2 | 2 |
4 | 13 | 240.16 | 36 | 14.37 | 711 | 368 | 3.77 / 100.15 | 2 | 2 |
5 | 13 | 21.68 | 36 | 14.74 | 319 | 169 | 3.94 / 100.32 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.49 | 292 | 804 | 4.74 / 101.12 | 2 | 9 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 26 | 14.88 | 429 | 166 | 0.17 / 91.97 | 2 | 2 |
2 | 7 | 2006.72 | 50 | 12.85 | 3272 | 2102 | 2.27 / 94.08 | 2 | 2 |
3 | 13 | 1218.88 | 36 | 13.45 | 2194 | 1062 | 3.33 / 95.14 | 2 | 3 |
4 | 13 | 321.88 | 36 | 14.25 | 844 | 433 | 3.76 / 95.57 | 2 | 2 |
5 | 8 | -0.28 | 190 | 14.52 | 294 | 811 | 4.57 / 96.38 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 14.87 | 436 | 169 | 0.17 / 87.21 | 2 | 2 |
2 | 7 | 2003.60 | 51 | 12.89 | 3246 | 2134 | 2.30 / 89.34 | 2 | 2 |
3 | 13 | 1335.96 | 32 | 13.46 | 2331 | 1004 | 3.31 / 90.34 | 2 | 2 |
4 | 13 | 423.08 | 32 | 14.16 | 1024 | 464 | 3.77 / 90.81 | 2 | 2 |
5 | 13 | 35.60 | 32 | 14.72 | 359 | 169 | 3.94 / 90.98 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.47 | 302 | 830 | 4.77 / 91.81 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 26 | 14.91 | 416 | 161 | 0.16 / 82.46 | 2 | 2 |
2 | 7 | 2006.00 | 50 | 12.91 | 3244 | 2094 | 2.26 / 84.56 | 2 | 2 |
3 | 13 | 1366.24 | 32 | 13.45 | 2378 | 1023 | 3.28 / 85.58 | 2 | 2 |
4 | 13 | 429.28 | 32 | 14.16 | 1023 | 464 | 3.74 / 86.05 | 2 | 2 |
5 | 13 | 38.68 | 32 | 14.73 | 358 | 169 | 3.91 / 86.21 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.48 | 299 | 823 | 4.73 / 87.04 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 25 | 14.90 | 420 | 156 | 0.16 / 77.78 | 2 | 2 |
2 | 7 | 2004.92 | 51 | 12.92 | 3239 | 2134 | 2.29 / 79.91 | 2 | 2 |
3 | 13 | 1199.24 | 32 | 13.56 | 2130 | 924 | 3.21 / 80.84 | 2 | 3 |
4 | 13 | 509.80 | 32 | 14.09 | 1134 | 511 | 3.73 / 81.35 | 2 | 2 |
5 | 13 | 26.36 | 32 | 14.76 | 336 | 159 | 3.88 / 81.51 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.49 | 289 | 796 | 4.68 / 82.30 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 25 | 14.93 | 421 | 157 | 0.16 / 73.26 | 2 | 2 |
2 | 7 | 2005.52 | 50 | 12.94 | 3241 | 2097 | 2.25 / 75.35 | 2 | 2 |
3 | 13 | 1187.28 | 32 | 13.57 | 2138 | 928 | 3.18 / 76.28 | 2 | 3 |
4 | 13 | 305.08 | 32 | 14.33 | 803 | 368 | 3.55 / 76.65 | 2 | 2 |
5 | 13 | 27.32 | 32 | 14.77 | 337 | 159 | 3.71 / 76.81 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.50 | 295 | 813 | 4.52 / 77.62 | 2 | 4 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 25 | 14.93 | 410 | 153 | 0.15 / 68.81 | 2 | 2 |
2 | 7 | 2005.32 | 50 | 12.96 | 3247 | 2104 | 2.26 / 70.91 | 2 | 2 |
3 | 13 | 1165.64 | 32 | 13.59 | 2086 | 907 | 3.16 / 71.82 | 2 | 3 |
4 | 13 | 291.88 | 32 | 14.37 | 769 | 354 | 3.52 / 72.17 | 2 | 2 |
5 | 13 | 27.52 | 32 | 14.80 | 322 | 152 | 3.67 / 72.32 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.53 | 281 | 776 | 4.45 / 73.10 | 2 | 5 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 25 | 14.95 | 408 | 152 | 0.15 / 64.36 | 2 | 2 |
2 | 7 | 2005.64 | 50 | 13.00 | 3204 | 2083 | 2.24 / 66.44 | 2 | 2 |
3 | 13 | 1163.68 | 32 | 13.60 | 2078 | 904 | 3.14 / 67.34 | 2 | 2 |
4 | 13 | 297.64 | 32 | 14.35 | 785 | 360 | 3.50 / 67.70 | 2 | 2 |
5 | 13 | 22.32 | 32 | 14.80 | 324 | 153 | 3.65 / 67.86 | 2 | 2 |
6 | 8 | -0.28 | 190 | 14.51 | 289 | 797 | 4.45 / 68.65 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 25 | 14.94 | 427 | 159 | 0.16 / 59.81 | 2 | 2 |
2 | 7 | 2001.16 | 50 | 13.00 | 3235 | 2103 | 2.26 / 61.91 | 2 | 2 |
3 | 13 | 1333.92 | 29 | 13.53 | 2326 | 913 | 3.17 / 62.83 | 2 | 2 |
4 | 13 | 434.56 | 29 | 14.20 | 1015 | 418 | 3.59 / 63.24 | 2 | 2 |
5 | 13 | 42.76 | 29 | 14.78 | 362 | 155 | 3.75 / 63.40 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.51 | 292 | 805 | 4.55 / 64.20 | 2 | 3 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 25 | 14.93 | 444 | 166 | 0.17 / 55.26 | 2 | 2 |
2 | 7 | 2003.68 | 50 | 13.01 | 3223 | 2097 | 2.26 / 57.36 | 2 | 2 |
3 | 13 | 1341.16 | 29 | 13.53 | 2327 | 913 | 3.18 / 58.27 | 2 | 2 |
4 | 13 | 433.80 | 29 | 14.20 | 1027 | 423 | 3.60 / 58.70 | 2 | 2 |
5 | 13 | 40.12 | 29 | 14.79 | 357 | 153 | 3.75 / 58.85 | 2 | 2 |
6 | 8 | -0.32 | 190 | 14.51 | 291 | 802 | 4.55 / 59.65 | 2 | 3 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 25 | 14.94 | 403 | 151 | 0.15 / 50.69 | 2 | 2 |
2 | 7 | 2010.60 | 50 | 13.01 | 3235 | 2104 | 2.25 / 52.80 | 2 | 2 |
3 | 13 | 1364.16 | 29 | 13.52 | 2363 | 926 | 3.18 / 53.72 | 2 | 2 |
4 | 13 | 425.36 | 29 | 14.22 | 1001 | 413 | 3.59 / 54.14 | 2 | 2 |
5 | 13 | 37.84 | 29 | 14.79 | 351 | 151 | 3.74 / 54.29 | 2 | 2 |
6 | 8 | -0.32 | 190 | 14.51 | 294 | 811 | 4.56 / 55.10 | 2 | 3 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 25 | 14.96 | 422 | 158 | 0.16 / 46.21 | 2 | 2 |
2 | 7 | 2002.96 | 50 | 13.03 | 3228 | 2103 | 2.26 / 48.32 | 2 | 2 |
3 | 13 | 1350.52 | 29 | 13.54 | 2319 | 911 | 3.17 / 49.23 | 2 | 3 |
4 | 13 | 453.40 | 29 | 14.21 | 1015 | 418 | 3.59 / 49.65 | 2 | 2 |
5 | 13 | 46.96 | 29 | 14.81 | 342 | 147 | 3.74 / 49.79 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.56 | 271 | 750 | 4.49 / 50.54 | 2 | 3 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 25 | 14.97 | 414 | 155 | 0.15 / 41.72 | 2 | 2 |
2 | 7 | 2002.80 | 50 | 13.02 | 3225 | 2099 | 2.25 / 43.81 | 2 | 2 |
3 | 13 | 1355.56 | 29 | 13.53 | 2328 | 913 | 3.17 / 44.73 | 2 | 2 |
4 | 13 | 460.56 | 29 | 14.21 | 1029 | 424 | 3.59 / 45.15 | 2 | 2 |
5 | 13 | 40.08 | 29 | 14.81 | 335 | 144 | 3.74 / 45.30 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.54 | 275 | 760 | 4.50 / 46.06 | 2 | 4 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 24 | 14.98 | 407 | 146 | 0.15 / 37.35 | 2 | 2 |
2 | 7 | 2005.40 | 50 | 13.03 | 3233 | 2106 | 2.25 / 39.46 | 2 | 2 |
3 | 13 | 1368.84 | 29 | 13.52 | 2354 | 923 | 3.18 / 40.38 | 2 | 2 |
4 | 13 | 281.20 | 29 | 14.44 | 733 | 307 | 3.48 / 40.69 | 2 | 2 |
5 | 13 | 25.40 | 29 | 14.86 | 308 | 133 | 3.62 / 40.82 | 2 | 2 |
6 | 8 | -0.36 | 190 | 14.57 | 268 | 742 | 4.36 / 41.56 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 24 | 14.99 | 402 | 145 | 0.14 / 32.87 | 2 | 2 |
2 | 7 | 2001.44 | 51 | 13.03 | 3225 | 2143 | 2.29 / 35.01 | 2 | 2 |
3 | 13 | 1335.04 | 29 | 13.53 | 2310 | 906 | 3.19 / 35.92 | 2 | 3 |
4 | 13 | 405.32 | 29 | 14.27 | 946 | 391 | 3.59 / 36.31 | 2 | 2 |
5 | 13 | 15.12 | 29 | 14.87 | 296 | 128 | 3.71 / 36.44 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.52 | 277 | 764 | 4.48 / 37.20 | 2 | 6 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 24 | 14.99 | 414 | 149 | 0.15 / 28.65 | 2 | 2 |
2 | 7 | 2005.76 | 50 | 13.04 | 3227 | 2104 | 2.25 / 30.75 | 2 | 2 |
3 | 13 | 1138.32 | 25 | 13.73 | 2036 | 699 | 2.95 / 31.45 | 2 | 5 |
4 | 13 | 482.52 | 25 | 14.24 | 1069 | 381 | 3.33 / 31.83 | 2 | 2 |
5 | 13 | 63.60 | 25 | 14.83 | 374 | 139 | 3.47 / 31.97 | 2 | 2 |
6 | 8 | -0.24 | 190 | 14.60 | 272 | 755 | 4.23 / 32.73 | 2 | 2 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 24 | 14.99 | 392 | 141 | 0.14 / 24.40 | 2 | 2 |
2 | 7 | 2001.76 | 51 | 13.04 | 3217 | 2139 | 2.28 / 26.54 | 2 | 2 |
3 | 13 | 1144.00 | 25 | 13.73 | 2027 | 696 | 2.98 / 27.23 | 2 | 3 |
4 | 13 | 495.72 | 25 | 14.23 | 1087 | 387 | 3.36 / 27.62 | 2 | 2 |
5 | 13 | 61.24 | 25 | 14.84 | 364 | 135 | 3.50 / 27.76 | 2 | 2 |
6 | 8 | -0.12 | 190 | 14.62 | 268 | 744 | 4.24 / 28.50 | 2 | 2 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 24 | 14.96 | 404 | 145 | 0.15 / 20.29 | 2 | 2 |
2 | 7 | 2000.44 | 50 | 13.05 | 3217 | 2099 | 2.24 / 22.39 | 2 | 2 |
3 | 13 | 1148.80 | 25 | 13.72 | 2036 | 698 | 2.94 / 23.08 | 2 | 4 |
4 | 13 | 325.12 | 25 | 14.44 | 807 | 291 | 3.23 / 23.38 | 2 | 2 |
5 | 13 | 70.96 | 25 | 14.84 | 377 | 140 | 3.37 / 23.52 | 2 | 2 |
6 | 8 | -0.16 | 190 | 14.63 | 267 | 742 | 4.12 / 24.26 | 2 | 4 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 25 | 14.94 | 400 | 149 | 0.15 / 16.09 | 2 | 2 |
2 | 3 | 929.12 | -1 | 14.94 | 400 | 0 | 0.00 / 16.09 | 2 | 2 |
3 | 3 | 1021.80 | 1 | 14.60 | 1891 | 28 | 0.18 / 16.12 | 2 | 2 |
4 | 7 | 1994.84 | 50 | 13.03 | 3205 | 2088 | 2.27 / 18.21 | 2 | 2 |
5 | 13 | 1128.52 | 25 | 13.72 | 2011 | 690 | 2.95 / 18.90 | 2 | 3 |
6 | 13 | 469.36 | 25 | 14.26 | 1040 | 371 | 3.33 / 19.27 | 2 | 2 |
7 | 13 | 49.48 | 25 | 14.86 | 348 | 129 | 3.45 / 19.40 | 2 | 2 |
8 | 8 | -0.20 | 190 | 14.58 | 268 | 742 | 4.20 / 20.14 | 2 | 2 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 24 | 14.90 | 402 | 144 | 0.14 / 12.47 | 2 | 2 |
2 | 3 | 954.88 | -1 | 14.90 | 402 | 0 | 0.00 / 12.47 | 2 | 2 |
3 | 3 | 1037.68 | 1 | 14.58 | 1914 | 28 | 0.17 / 12.49 | 2 | 2 |
4 | 7 | 1504.56 | 50 | 13.39 | 2510 | 1680 | 1.85 / 14.17 | 2 | 3 |
5 | 13 | 1115.36 | 25 | 13.74 | 1983 | 681 | 2.53 / 14.86 | 2 | 3 |
6 | 13 | 250.44 | 25 | 14.52 | 677 | 246 | 2.78 / 15.10 | 2 | 2 |
7 | 13 | 20.04 | 25 | 14.89 | 295 | 110 | 2.89 / 15.21 | 2 | 2 |
8 | 8 | -0.12 | 190 | 14.58 | 265 | 734 | 3.62 / 15.94 | 2 | 3 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 24 | 14.86 | 415 | 148 | 0.15 / 8.47 | 2 | 2 |
2 | 3 | 942.40 | -1 | 14.86 | 415 | 0 | 0.00 / 8.47 | 2 | 2 |
3 | 3 | 1042.36 | 1 | 14.57 | 1900 | 28 | 0.18 / 8.50 | 2 | 2 |
4 | 7 | 1502.40 | 74 | 13.17 | 2499 | 2435 | 2.61 / 10.94 | 2 | 3 |
5 | 13 | 501.64 | 20 | 14.21 | 1089 | 309 | 2.92 / 11.25 | 2 | 2 |
6 | 13 | 137.36 | 20 | 14.69 | 489 | 144 | 3.06 / 11.39 | 2 | 2 |
7 | 8 | 0.12 | 240 | 14.54 | 267 | 932 | 4.00 / 12.32 | 2 | 27 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 25 | 14.82 | 399 | 148 | 0.15 / 4.44 | 2 | 2 |
2 | 3 | 914.72 | -2 | 14.82 | 399 | 0 | 0.00 / 4.44 | 2 | 2 |
3 | 3 | 1087.20 | 2 | 14.47 | 1947 | 56 | 0.20 / 4.49 | 2 | 2 |
4 | 7 | 1510.64 | 75 | 13.06 | 2498 | 2447 | 2.65 / 6.94 | 2 | 2 |
5 | 13 | 538.40 | 20 | 14.13 | 1136 | 321 | 2.97 / 7.26 | 2 | 2 |
6 | 13 | 147.44 | 20 | 14.62 | 505 | 148 | 3.12 / 7.41 | 2 | 2 |
7 | 8 | 0.04 | 240 | 14.51 | 263 | 916 | 4.04 / 8.33 | 2 | 31 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 25 | 14.90 | 389 | 145 | 0.14 / 1.41 | 2 | 2 |
2 | 3 | 916.12 | -2 | 14.90 | 389 | 0 | 0.00 / 1.41 | 2 | 2 |
3 | 3 | 1097.88 | 3 | 14.10 | 1974 | 84 | 0.23 / 1.50 | 2 | 2 |
4 | 7 | 1021.68 | 75 | 13.22 | 1809 | 1794 | 2.02 / 3.29 | 2 | 2 |
5 | 13 | 33.88 | 20 | 14.73 | 313 | 92 | 2.11 / 3.38 | 2 | 2 |
6 | 8 | -0.08 | 239 | 14.45 | 263 | 908 | 3.02 / 4.29 | 2 | 243 |
Average= | 2.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 82.40 | 24 | 14.65 | 343 | 121 | 0.12 / 0.12 | 2 | 2 |
2 | 7 | 91.40 | 75 | 14.53 | 351 | 383 | 0.50 / 0.50 | 2 | 2 |
3 | 8 | 0.28 | 240 | 14.75 | 216 | 765 | 1.27 / 1.27 | 2 | 64 |
Average= | 1.27 (KJ/cycle) |