SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 16 | 15.06 | 440 | 106 | 0.11 / 491.36 | 6 | 6 |
2 | 7 | 2003.68 | 40 | 14.68 | 2945 | 1729 | 1.84 / 493.09 | 6 | 23 |
3 | 13 | 1373.16 | 20 | 14.76 | 2116 | 625 | 2.46 / 493.71 | 5 | 24 |
4 | 13 | 857.32 | 20 | 14.85 | 1465 | 435 | 2.90 / 494.15 | 5 | 31 |
5 | 13 | 235.56 | 20 | 15.04 | 629 | 189 | 3.08 / 494.34 | 6 | 24 |
6 | 8 | 0.16 | 291 | 15.05 | 284 | 1244 | 4.33 / 495.58 | 6 | 135 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 16 | 15.06 | 446 | 107 | 0.11 / 486.93 | 6 | 6 |
2 | 7 | 2004.20 | 40 | 14.69 | 2926 | 1719 | 1.83 / 488.65 | 6 | 21 |
3 | 13 | 1458.52 | 20 | 14.75 | 2243 | 662 | 2.49 / 489.31 | 5 | 27 |
4 | 13 | 894.88 | 20 | 14.84 | 1527 | 453 | 2.94 / 489.77 | 5 | 30 |
5 | 13 | 240.84 | 20 | 15.04 | 632 | 190 | 3.13 / 489.96 | 6 | 24 |
6 | 13 | 91.56 | 20 | 15.07 | 422 | 127 | 3.26 / 490.08 | 6 | 16 |
7 | 8 | 0.08 | 274 | 15.05 | 283 | 1167 | 4.43 / 491.25 | 6 | 145 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 16 | 15.05 | 437 | 105 | 0.11 / 482.53 | 6 | 6 |
2 | 7 | 2003.12 | 40 | 14.68 | 2957 | 1736 | 1.84 / 484.27 | 6 | 20 |
3 | 13 | 1400.24 | 20 | 14.77 | 2133 | 630 | 2.47 / 484.90 | 5 | 26 |
4 | 13 | 847.32 | 20 | 14.86 | 1459 | 434 | 2.91 / 485.33 | 5 | 30 |
5 | 13 | 233.64 | 20 | 15.04 | 632 | 190 | 3.10 / 485.52 | 6 | 23 |
6 | 13 | 90.44 | 20 | 15.08 | 423 | 128 | 3.22 / 485.65 | 6 | 19 |
7 | 8 | 0.08 | 272 | 15.05 | 287 | 1175 | 4.40 / 486.83 | 6 | 136 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 16 | 15.05 | 427 | 103 | 0.10 / 478.21 | 6 | 6 |
2 | 7 | 2011.40 | 40 | 14.69 | 2938 | 1726 | 1.83 / 479.93 | 6 | 23 |
3 | 13 | 1385.92 | 20 | 14.77 | 2096 | 619 | 2.45 / 480.55 | 5 | 25 |
4 | 13 | 825.64 | 20 | 14.86 | 1423 | 423 | 2.87 / 480.98 | 5 | 36 |
5 | 13 | 247.64 | 20 | 15.03 | 647 | 194 | 3.07 / 481.17 | 6 | 23 |
6 | 8 | 0.20 | 291 | 15.05 | 287 | 1257 | 4.32 / 482.43 | 6 | 147 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 16 | 15.05 | 446 | 107 | 0.11 / 473.75 | 6 | 8 |
2 | 7 | 2011.72 | 40 | 14.70 | 2949 | 1734 | 1.84 / 475.49 | 8 | 19 |
3 | 13 | 1455.08 | 20 | 14.76 | 2201 | 650 | 2.49 / 476.14 | 5 | 30 |
4 | 13 | 901.72 | 20 | 14.84 | 1524 | 452 | 2.94 / 476.59 | 5 | 33 |
5 | 13 | 242.88 | 20 | 15.03 | 644 | 194 | 3.14 / 476.78 | 6 | 32 |
6 | 13 | 123.56 | 20 | 15.06 | 478 | 144 | 3.28 / 476.93 | 6 | 28 |
7 | 8 | 0.20 | 272 | 15.04 | 288 | 1178 | 4.46 / 478.10 | 6 | 133 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 16 | 15.04 | 455 | 109 | 0.11 / 469.33 | 6 | 6 |
2 | 7 | 2007.64 | 40 | 14.69 | 2944 | 1730 | 1.84 / 471.06 | 6 | 21 |
3 | 13 | 1409.80 | 20 | 14.76 | 2165 | 639 | 2.48 / 471.70 | 5 | 27 |
4 | 13 | 845.20 | 20 | 14.86 | 1456 | 433 | 2.91 / 472.14 | 5 | 34 |
5 | 13 | 217.80 | 20 | 15.04 | 610 | 183 | 3.09 / 472.32 | 6 | 31 |
6 | 13 | 95.44 | 20 | 15.06 | 438 | 132 | 3.23 / 472.45 | 6 | 28 |
7 | 8 | 0.12 | 272 | 15.04 | 292 | 1195 | 4.42 / 473.65 | 6 | 143 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 16 | 15.05 | 433 | 104 | 0.10 / 464.89 | 6 | 6 |
2 | 7 | 2009.24 | 40 | 14.69 | 2945 | 1730 | 1.83 / 466.62 | 6 | 23 |
3 | 13 | 1420.36 | 20 | 14.76 | 2169 | 640 | 2.48 / 467.26 | 5 | 31 |
4 | 13 | 856.16 | 20 | 14.85 | 1469 | 436 | 2.91 / 467.70 | 5 | 32 |
5 | 13 | 230.20 | 20 | 15.03 | 627 | 188 | 3.10 / 467.89 | 6 | 34 |
6 | 13 | 106.64 | 20 | 15.06 | 455 | 137 | 3.24 / 468.03 | 6 | 33 |
7 | 8 | -0.08 | 272 | 15.04 | 293 | 1199 | 4.44 / 469.22 | 6 | 142 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 16 | 15.05 | 445 | 107 | 0.11 / 460.43 | 6 | 6 |
2 | 7 | 2005.24 | 40 | 14.69 | 2964 | 1742 | 1.85 / 462.18 | 6 | 19 |
3 | 13 | 1465.64 | 20 | 14.76 | 2250 | 664 | 2.51 / 462.84 | 5 | 26 |
4 | 13 | 863.20 | 20 | 14.86 | 1466 | 436 | 2.95 / 463.28 | 5 | 39 |
5 | 13 | 223.16 | 20 | 15.04 | 615 | 185 | 3.13 / 463.46 | 6 | 32 |
6 | 13 | 109.84 | 20 | 15.06 | 453 | 136 | 3.27 / 463.60 | 6 | 19 |
7 | 8 | -0.12 | 274 | 15.04 | 289 | 1191 | 4.46 / 464.79 | 6 | 139 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 16 | 15.05 | 454 | 109 | 0.11 / 456.02 | 6 | 6 |
2 | 7 | 2007.96 | 40 | 14.69 | 2937 | 1726 | 1.84 / 457.75 | 6 | 19 |
3 | 13 | 1417.44 | 20 | 14.78 | 2167 | 641 | 2.48 / 458.39 | 5 | 27 |
4 | 13 | 819.28 | 20 | 14.87 | 1420 | 422 | 2.90 / 458.81 | 5 | 33 |
5 | 13 | 211.76 | 20 | 15.05 | 598 | 180 | 3.08 / 458.99 | 6 | 29 |
6 | 13 | 136.76 | 20 | 15.06 | 495 | 149 | 3.23 / 459.14 | 6 | 23 |
7 | 8 | 0.00 | 272 | 15.05 | 290 | 1187 | 4.41 / 460.33 | 6 | 139 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 16 | 15.06 | 447 | 108 | 0.11 / 451.58 | 6 | 7 |
2 | 7 | 2004.32 | 41 | 14.69 | 2943 | 1773 | 1.88 / 453.35 | 7 | 21 |
3 | 13 | 1376.32 | 20 | 14.77 | 2131 | 629 | 2.51 / 453.98 | 5 | 29 |
4 | 13 | 856.40 | 20 | 14.86 | 1455 | 432 | 2.94 / 454.41 | 5 | 33 |
5 | 13 | 230.56 | 20 | 15.04 | 624 | 188 | 3.13 / 454.60 | 6 | 27 |
6 | 13 | 116.84 | 20 | 15.06 | 462 | 139 | 3.27 / 454.74 | 6 | 28 |
7 | 8 | 0.04 | 272 | 15.04 | 287 | 1174 | 4.44 / 455.91 | 6 | 140 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.80 | 16 | 15.05 | 447 | 108 | 0.11 / 447.13 | 6 | 6 |
2 | 7 | 2010.72 | 40 | 14.69 | 2956 | 1737 | 1.84 / 448.87 | 6 | 28 |
3 | 13 | 1467.16 | 20 | 14.75 | 2251 | 664 | 2.51 / 449.53 | 5 | 25 |
4 | 13 | 864.96 | 20 | 14.85 | 1482 | 440 | 2.95 / 449.97 | 5 | 33 |
5 | 13 | 251.36 | 20 | 15.03 | 650 | 195 | 3.14 / 450.17 | 6 | 21 |
6 | 13 | 105.64 | 20 | 15.07 | 446 | 134 | 3.28 / 450.30 | 6 | 26 |
7 | 8 | 0.00 | 272 | 15.05 | 286 | 1171 | 4.45 / 451.47 | 6 | 133 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 16 | 15.06 | 447 | 108 | 0.11 / 442.70 | 6 | 6 |
2 | 7 | 2011.12 | 40 | 14.70 | 2949 | 1734 | 1.84 / 444.44 | 19 | 19 |
3 | 13 | 1367.80 | 20 | 14.77 | 2126 | 628 | 2.47 / 445.07 | 5 | 35 |
4 | 13 | 889.00 | 20 | 14.85 | 1508 | 448 | 2.92 / 445.51 | 5 | 34 |
5 | 13 | 232.28 | 20 | 15.04 | 632 | 190 | 3.11 / 445.70 | 6 | 27 |
6 | 13 | 121.96 | 20 | 15.07 | 472 | 142 | 3.25 / 445.85 | 6 | 23 |
7 | 8 | 0.00 | 272 | 15.05 | 287 | 1175 | 4.42 / 447.02 | 6 | 130 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 16 | 15.06 | 424 | 102 | 0.10 / 438.36 | 6 | 6 |
2 | 7 | 2003.08 | 40 | 14.70 | 2918 | 1716 | 1.82 / 440.07 | 6 | 17 |
3 | 13 | 1337.60 | 20 | 14.78 | 2072 | 612 | 2.43 / 440.68 | 5 | 23 |
4 | 13 | 793.48 | 20 | 14.87 | 1385 | 412 | 2.84 / 441.10 | 5 | 34 |
5 | 13 | 222.44 | 20 | 15.04 | 620 | 186 | 3.03 / 441.28 | 6 | 23 |
6 | 13 | 111.44 | 20 | 15.07 | 459 | 138 | 3.17 / 441.42 | 6 | 24 |
7 | 8 | 0.20 | 272 | 15.05 | 287 | 1175 | 4.34 / 442.60 | 6 | 131 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.20 | 16 | 15.06 | 446 | 107 | 0.11 / 433.99 | 6 | 6 |
2 | 7 | 2003.08 | 40 | 14.69 | 2959 | 1739 | 1.85 / 435.73 | 6 | 20 |
3 | 13 | 1373.76 | 20 | 14.77 | 2130 | 629 | 2.48 / 436.36 | 5 | 29 |
4 | 13 | 813.32 | 20 | 14.87 | 1413 | 420 | 2.90 / 436.78 | 5 | 43 |
5 | 13 | 193.36 | 20 | 15.06 | 568 | 171 | 3.07 / 436.95 | 6 | 35 |
6 | 13 | 120.80 | 20 | 15.07 | 466 | 140 | 3.21 / 437.09 | 6 | 27 |
7 | 8 | 0.08 | 272 | 15.05 | 284 | 1163 | 4.37 / 438.25 | 6 | 160 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 16 | 15.06 | 418 | 101 | 0.10 / 429.58 | 6 | 6 |
2 | 7 | 2005.28 | 40 | 14.70 | 2964 | 1743 | 1.84 / 431.33 | 6 | 21 |
3 | 13 | 1409.88 | 20 | 14.77 | 2180 | 644 | 2.49 / 431.97 | 5 | 37 |
4 | 13 | 805.56 | 20 | 14.88 | 1389 | 413 | 2.90 / 432.38 | 5 | 43 |
5 | 13 | 216.48 | 20 | 15.05 | 605 | 182 | 3.08 / 432.57 | 6 | 28 |
6 | 13 | 110.84 | 20 | 15.08 | 455 | 137 | 3.22 / 432.70 | 6 | 23 |
7 | 8 | 0.12 | 274 | 15.06 | 286 | 1180 | 4.40 / 433.88 | 6 | 158 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 16 | 15.04 | 446 | 107 | 0.11 / 425.14 | 6 | 6 |
2 | 7 | 2013.20 | 40 | 14.69 | 2987 | 1755 | 1.86 / 426.89 | 6 | 21 |
3 | 13 | 1422.76 | 20 | 14.78 | 2189 | 647 | 2.51 / 427.54 | 5 | 22 |
4 | 13 | 890.00 | 20 | 14.85 | 1524 | 453 | 2.96 / 427.99 | 5 | 34 |
5 | 13 | 252.12 | 20 | 15.04 | 656 | 197 | 3.16 / 428.19 | 6 | 28 |
6 | 13 | 102.28 | 20 | 15.08 | 444 | 134 | 3.29 / 428.33 | 6 | 31 |
7 | 8 | 0.08 | 270 | 15.06 | 285 | 1159 | 4.45 / 429.48 | 6 | 133 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 16 | 15.05 | 447 | 108 | 0.11 / 420.70 | 6 | 6 |
2 | 7 | 2009.80 | 40 | 14.71 | 2955 | 1739 | 1.85 / 422.44 | 6 | 18 |
3 | 13 | 1414.56 | 20 | 14.78 | 2161 | 639 | 2.49 / 423.08 | 5 | 27 |
4 | 13 | 882.52 | 20 | 14.86 | 1494 | 444 | 2.93 / 423.53 | 5 | 33 |
5 | 13 | 160.32 | 20 | 15.05 | 549 | 165 | 3.09 / 423.69 | 6 | 25 |
6 | 13 | 46.24 | 20 | 15.08 | 381 | 115 | 3.21 / 423.81 | 6 | 34 |
7 | 8 | 0.00 | 270 | 15.04 | 302 | 1226 | 4.44 / 425.03 | 6 | 138 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 16 | 15.05 | 446 | 107 | 0.11 / 416.31 | 6 | 6 |
2 | 7 | 2002.76 | 40 | 14.70 | 2939 | 1728 | 1.84 / 418.04 | 6 | 21 |
3 | 13 | 1365.80 | 20 | 14.78 | 2139 | 632 | 2.47 / 418.67 | 5 | 24 |
4 | 13 | 817.36 | 20 | 14.88 | 1419 | 422 | 2.89 / 419.09 | 5 | 33 |
5 | 13 | 188.12 | 20 | 15.04 | 579 | 174 | 3.06 / 419.27 | 5 | 34 |
6 | 13 | 34.00 | 20 | 15.08 | 359 | 108 | 3.17 / 419.38 | 6 | 31 |
7 | 8 | 0.08 | 272 | 15.04 | 298 | 1219 | 4.39 / 420.60 | 6 | 146 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 16 | 15.06 | 448 | 108 | 0.11 / 411.95 | 6 | 6 |
2 | 7 | 2013.28 | 40 | 14.70 | 2972 | 1748 | 1.86 / 413.70 | 6 | 22 |
3 | 13 | 1380.60 | 20 | 14.79 | 2093 | 619 | 2.47 / 414.32 | 5 | 26 |
4 | 13 | 781.68 | 20 | 14.88 | 1364 | 406 | 2.88 / 414.73 | 5 | 36 |
5 | 13 | 119.72 | 20 | 15.07 | 487 | 147 | 3.03 / 414.87 | 6 | 35 |
6 | 13 | 49.76 | 20 | 15.08 | 386 | 116 | 3.14 / 414.99 | 6 | 28 |
7 | 8 | 0.04 | 270 | 15.04 | 299 | 1214 | 4.36 / 416.20 | 6 | 136 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 16 | 15.05 | 439 | 106 | 0.11 / 407.55 | 6 | 6 |
2 | 7 | 2010.20 | 40 | 14.70 | 2973 | 1748 | 1.85 / 409.30 | 6 | 23 |
3 | 13 | 1449.16 | 20 | 14.78 | 2218 | 656 | 2.51 / 409.96 | 5 | 24 |
4 | 13 | 790.40 | 20 | 14.89 | 1376 | 410 | 2.92 / 410.37 | 5 | 32 |
5 | 13 | 146.44 | 20 | 15.06 | 525 | 158 | 3.08 / 410.53 | 5 | 33 |
6 | 13 | 47.16 | 20 | 15.09 | 376 | 113 | 3.19 / 410.64 | 6 | 30 |
7 | 8 | 0.12 | 272 | 15.05 | 295 | 1208 | 4.40 / 411.85 | 6 | 148 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 16 | 15.05 | 450 | 108 | 0.11 / 403.15 | 6 | 6 |
2 | 7 | 2007.60 | 40 | 14.71 | 2946 | 1733 | 1.84 / 404.88 | 6 | 19 |
3 | 13 | 1445.36 | 20 | 14.78 | 2194 | 649 | 2.49 / 405.53 | 5 | 29 |
4 | 13 | 875.20 | 20 | 14.86 | 1498 | 445 | 2.94 / 405.98 | 5 | 32 |
5 | 13 | 109.20 | 20 | 15.07 | 470 | 142 | 3.08 / 406.12 | 5 | 33 |
6 | 13 | 42.00 | 20 | 15.08 | 369 | 111 | 3.19 / 406.23 | 6 | 31 |
7 | 8 | -0.04 | 272 | 15.04 | 298 | 1219 | 4.41 / 407.45 | 6 | 148 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 16 | 15.05 | 444 | 107 | 0.11 / 398.70 | 6 | 6 |
2 | 7 | 2006.84 | 40 | 14.71 | 2950 | 1736 | 1.84 / 400.43 | 6 | 13 |
3 | 13 | 1490.28 | 20 | 14.77 | 2261 | 668 | 2.51 / 401.10 | 5 | 31 |
4 | 13 | 871.80 | 20 | 14.87 | 1479 | 440 | 2.95 / 401.54 | 5 | 33 |
5 | 13 | 173.72 | 20 | 15.06 | 561 | 169 | 3.12 / 401.71 | 6 | 31 |
6 | 13 | 52.36 | 20 | 15.08 | 384 | 116 | 3.24 / 401.83 | 6 | 28 |
7 | 8 | -0.04 | 272 | 15.04 | 297 | 1215 | 4.45 / 403.04 | 6 | 134 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 16 | 15.05 | 438 | 105 | 0.11 / 394.29 | 6 | 6 |
2 | 7 | 2005.48 | 40 | 14.71 | 2942 | 1731 | 1.84 / 396.02 | 6 | 20 |
3 | 13 | 1445.56 | 20 | 14.78 | 2211 | 654 | 2.49 / 396.68 | 5 | 29 |
4 | 13 | 803.44 | 20 | 14.88 | 1402 | 417 | 2.91 / 397.09 | 5 | 39 |
5 | 13 | 141.84 | 20 | 15.07 | 515 | 155 | 3.06 / 397.25 | 6 | 33 |
6 | 13 | 35.16 | 20 | 15.09 | 362 | 109 | 3.17 / 397.36 | 6 | 32 |
7 | 8 | -0.12 | 272 | 15.05 | 301 | 1232 | 4.40 / 398.59 | 6 | 141 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 16 | 15.05 | 431 | 104 | 0.10 / 389.92 | 6 | 6 |
2 | 7 | 2009.00 | 40 | 14.72 | 2931 | 1726 | 1.83 / 391.65 | 6 | 24 |
3 | 13 | 1388.64 | 20 | 14.79 | 2131 | 630 | 2.46 / 392.28 | 5 | 26 |
4 | 13 | 796.32 | 20 | 14.89 | 1385 | 412 | 2.87 / 392.69 | 5 | 39 |
5 | 13 | 178.92 | 20 | 15.06 | 565 | 170 | 3.04 / 392.86 | 6 | 33 |
6 | 13 | 33.28 | 20 | 15.09 | 355 | 107 | 3.15 / 392.97 | 6 | 34 |
7 | 8 | 0.04 | 272 | 15.05 | 297 | 1216 | 4.37 / 394.19 | 6 | 137 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 16 | 15.04 | 433 | 104 | 0.10 / 385.57 | 6 | 6 |
2 | 7 | 2004.16 | 40 | 14.72 | 2900 | 1708 | 1.81 / 387.28 | 6 | 18 |
3 | 13 | 1430.40 | 20 | 14.79 | 2172 | 642 | 2.45 / 387.92 | 5 | 24 |
4 | 13 | 795.72 | 20 | 14.89 | 1384 | 412 | 2.87 / 388.33 | 5 | 40 |
5 | 13 | 120.56 | 20 | 15.07 | 486 | 146 | 3.01 / 388.48 | 6 | 30 |
6 | 13 | 45.76 | 20 | 15.09 | 374 | 113 | 3.13 / 388.59 | 6 | 29 |
7 | 13 | 10.04 | 20 | 15.09 | 320 | 97 | 3.22 / 388.69 | 6 | 26 |
8 | 8 | -0.08 | 253 | 15.04 | 298 | 1134 | 4.36 / 389.82 | 6 | 141 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 16 | 15.05 | 430 | 104 | 0.10 / 381.14 | 6 | 6 |
2 | 7 | 2009.40 | 41 | 14.70 | 2960 | 1784 | 1.89 / 382.93 | 6 | 30 |
3 | 13 | 1387.52 | 20 | 14.79 | 2134 | 631 | 2.52 / 383.56 | 5 | 29 |
4 | 13 | 821.32 | 20 | 14.88 | 1412 | 420 | 2.94 / 383.98 | 5 | 34 |
5 | 13 | 123.52 | 20 | 15.07 | 496 | 149 | 3.09 / 384.13 | 5 | 35 |
6 | 13 | 29.28 | 20 | 15.09 | 355 | 107 | 3.20 / 384.23 | 6 | 28 |
7 | 8 | 0.00 | 272 | 15.04 | 301 | 1231 | 4.43 / 385.46 | 6 | 142 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 16 | 15.05 | 435 | 105 | 0.10 / 376.77 | 6 | 7 |
2 | 7 | 2009.36 | 40 | 14.73 | 2896 | 1706 | 1.81 / 378.48 | 7 | 17 |
3 | 13 | 1434.48 | 20 | 14.79 | 2183 | 646 | 2.46 / 379.12 | 5 | 27 |
4 | 13 | 826.44 | 20 | 14.88 | 1414 | 421 | 2.88 / 379.54 | 5 | 36 |
5 | 13 | 178.72 | 20 | 15.05 | 575 | 173 | 3.05 / 379.72 | 6 | 32 |
6 | 13 | 31.88 | 20 | 15.09 | 349 | 105 | 3.16 / 379.82 | 6 | 31 |
7 | 8 | -0.08 | 272 | 15.04 | 297 | 1215 | 4.37 / 381.04 | 6 | 144 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 16 | 15.05 | 437 | 105 | 0.11 / 372.46 | 6 | 6 |
2 | 7 | 2011.32 | 40 | 14.71 | 2929 | 1723 | 1.83 / 374.18 | 6 | 17 |
3 | 13 | 1357.16 | 20 | 14.80 | 2105 | 623 | 2.45 / 374.80 | 5 | 27 |
4 | 13 | 731.20 | 20 | 14.91 | 1305 | 389 | 2.84 / 375.19 | 5 | 36 |
5 | 13 | 121.96 | 20 | 15.07 | 492 | 148 | 2.99 / 375.34 | 6 | 33 |
6 | 13 | 26.80 | 20 | 15.09 | 348 | 105 | 3.09 / 375.45 | 6 | 32 |
7 | 8 | -0.12 | 272 | 15.04 | 298 | 1219 | 4.31 / 376.67 | 6 | 143 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 16 | 15.05 | 440 | 106 | 0.11 / 368.12 | 6 | 6 |
2 | 7 | 2006.40 | 40 | 14.71 | 2928 | 1723 | 1.83 / 369.84 | 6 | 16 |
3 | 13 | 1398.20 | 20 | 14.79 | 2133 | 631 | 2.46 / 370.47 | 5 | 21 |
4 | 13 | 803.64 | 20 | 14.88 | 1385 | 412 | 2.87 / 370.89 | 5 | 31 |
5 | 13 | 107.04 | 20 | 15.07 | 467 | 141 | 3.01 / 371.03 | 6 | 33 |
6 | 13 | 35.00 | 20 | 15.09 | 359 | 108 | 3.12 / 371.13 | 6 | 35 |
7 | 8 | -0.12 | 270 | 15.04 | 300 | 1218 | 4.34 / 372.35 | 6 | 134 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 16 | 15.06 | 443 | 107 | 0.11 / 363.69 | 6 | 6 |
2 | 7 | 2007.16 | 41 | 14.71 | 2932 | 1768 | 1.88 / 365.46 | 6 | 19 |
3 | 13 | 1451.24 | 20 | 14.78 | 2225 | 658 | 2.53 / 366.12 | 5 | 38 |
4 | 13 | 807.68 | 20 | 14.88 | 1407 | 419 | 2.95 / 366.53 | 5 | 36 |
5 | 13 | 160.12 | 20 | 15.07 | 532 | 160 | 3.11 / 366.69 | 6 | 24 |
6 | 13 | 85.28 | 20 | 15.08 | 423 | 128 | 3.24 / 366.82 | 6 | 30 |
7 | 8 | 0.00 | 274 | 15.05 | 289 | 1192 | 4.43 / 368.01 | 6 | 148 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 16 | 15.06 | 422 | 102 | 0.10 / 359.28 | 6 | 7 |
2 | 7 | 2004.64 | 40 | 14.73 | 2909 | 1714 | 1.82 / 360.99 | 7 | 17 |
3 | 13 | 1420.16 | 20 | 14.79 | 2152 | 637 | 2.45 / 361.63 | 5 | 29 |
4 | 13 | 860.80 | 20 | 14.87 | 1467 | 436 | 2.89 / 362.07 | 5 | 27 |
5 | 13 | 241.60 | 20 | 15.05 | 639 | 192 | 3.08 / 362.26 | 6 | 23 |
6 | 13 | 87.88 | 20 | 15.09 | 421 | 127 | 3.21 / 362.39 | 6 | 32 |
7 | 8 | 0.00 | 276 | 15.05 | 288 | 1196 | 4.40 / 363.58 | 6 | 150 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 16 | 15.06 | 451 | 109 | 0.11 / 354.84 | 6 | 6 |
2 | 7 | 2010.80 | 40 | 14.72 | 2934 | 1728 | 1.84 / 356.56 | 6 | 19 |
3 | 13 | 1411.28 | 20 | 14.79 | 2163 | 640 | 2.48 / 357.20 | 5 | 25 |
4 | 13 | 858.76 | 20 | 14.88 | 1464 | 436 | 2.91 / 357.64 | 5 | 30 |
5 | 13 | 238.64 | 20 | 15.05 | 642 | 193 | 3.10 / 357.83 | 6 | 30 |
6 | 13 | 125.08 | 20 | 15.08 | 479 | 144 | 3.25 / 357.98 | 6 | 29 |
7 | 8 | 0.08 | 274 | 15.06 | 291 | 1201 | 4.45 / 359.18 | 6 | 132 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 16 | 15.06 | 451 | 109 | 0.11 / 350.41 | 6 | 6 |
2 | 7 | 2013.00 | 40 | 14.72 | 2943 | 1733 | 1.84 / 352.15 | 6 | 25 |
3 | 13 | 1458.84 | 20 | 14.79 | 2207 | 653 | 2.49 / 352.80 | 5 | 19 |
4 | 13 | 843.88 | 20 | 14.89 | 1429 | 426 | 2.92 / 353.23 | 5 | 27 |
5 | 13 | 197.88 | 20 | 15.07 | 590 | 178 | 3.10 / 353.40 | 6 | 32 |
6 | 13 | 88.00 | 20 | 15.09 | 427 | 129 | 3.23 / 353.53 | 6 | 28 |
7 | 8 | 0.08 | 272 | 15.06 | 292 | 1196 | 4.42 / 354.73 | 6 | 144 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 16 | 15.06 | 418 | 101 | 0.10 / 346.02 | 6 | 6 |
2 | 7 | 2006.96 | 41 | 14.72 | 2917 | 1760 | 1.86 / 347.78 | 6 | 18 |
3 | 13 | 1418.04 | 20 | 14.79 | 2154 | 637 | 2.50 / 348.41 | 5 | 24 |
4 | 13 | 753.36 | 20 | 14.91 | 1325 | 395 | 2.89 / 348.81 | 5 | 31 |
5 | 13 | 184.24 | 20 | 15.06 | 575 | 173 | 3.07 / 348.98 | 6 | 24 |
6 | 13 | 74.84 | 20 | 15.09 | 411 | 124 | 3.19 / 349.11 | 6 | 21 |
7 | 8 | 0.08 | 272 | 15.05 | 293 | 1199 | 4.39 / 350.31 | 6 | 136 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 16 | 15.06 | 436 | 105 | 0.11 / 341.57 | 6 | 8 |
2 | 7 | 2003.76 | 40 | 14.73 | 2932 | 1728 | 1.83 / 343.29 | 8 | 18 |
3 | 13 | 1453.68 | 20 | 14.79 | 2210 | 654 | 2.49 / 343.95 | 5 | 29 |
4 | 13 | 838.96 | 20 | 14.89 | 1435 | 427 | 2.91 / 344.37 | 5 | 34 |
5 | 13 | 256.60 | 20 | 15.05 | 672 | 202 | 3.12 / 344.58 | 5 | 36 |
6 | 13 | 87.56 | 20 | 15.09 | 428 | 129 | 3.25 / 344.71 | 6 | 24 |
7 | 8 | 0.04 | 276 | 15.06 | 291 | 1210 | 4.45 / 345.92 | 6 | 156 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 16 | 15.05 | 444 | 107 | 0.11 / 337.16 | 6 | 6 |
2 | 7 | 2010.72 | 40 | 14.73 | 2958 | 1743 | 1.85 / 338.90 | 6 | 18 |
3 | 13 | 1427.84 | 20 | 14.80 | 2188 | 648 | 2.50 / 339.55 | 5 | 27 |
4 | 13 | 800.00 | 20 | 14.90 | 1396 | 416 | 2.91 / 339.96 | 5 | 30 |
5 | 13 | 150.44 | 20 | 15.08 | 526 | 159 | 3.07 / 340.12 | 5 | 35 |
6 | 13 | 39.64 | 20 | 15.10 | 364 | 110 | 3.18 / 340.23 | 6 | 24 |
7 | 8 | -0.04 | 272 | 15.05 | 300 | 1228 | 4.41 / 341.46 | 6 | 146 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 16 | 15.05 | 436 | 105 | 0.10 / 332.66 | 6 | 6 |
2 | 7 | 2013.20 | 40 | 14.73 | 2959 | 1743 | 1.85 / 334.40 | 6 | 20 |
3 | 13 | 1537.28 | 20 | 14.78 | 2315 | 684 | 2.53 / 335.08 | 5 | 27 |
4 | 13 | 797.88 | 20 | 14.91 | 1374 | 410 | 2.94 / 335.49 | 5 | 33 |
5 | 13 | 227.44 | 20 | 15.05 | 637 | 192 | 3.13 / 335.69 | 5 | 33 |
6 | 13 | 19.44 | 20 | 15.10 | 345 | 104 | 3.24 / 335.79 | 6 | 31 |
7 | 8 | -0.12 | 272 | 15.05 | 308 | 1261 | 4.50 / 337.05 | 6 | 144 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 16 | 15.06 | 430 | 104 | 0.10 / 328.30 | 6 | 6 |
2 | 7 | 2010.68 | 40 | 14.74 | 2920 | 1722 | 1.83 / 330.02 | 6 | 22 |
3 | 13 | 1411.76 | 20 | 14.80 | 2168 | 642 | 2.47 / 330.66 | 5 | 26 |
4 | 13 | 802.76 | 20 | 14.90 | 1397 | 416 | 2.88 / 331.08 | 5 | 32 |
5 | 13 | 108.40 | 20 | 15.09 | 471 | 142 | 3.03 / 331.22 | 5 | 32 |
6 | 13 | 18.24 | 20 | 15.11 | 335 | 101 | 3.13 / 331.32 | 6 | 33 |
7 | 8 | 0.00 | 272 | 15.06 | 300 | 1229 | 4.36 / 332.55 | 6 | 156 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 16 | 15.06 | 440 | 106 | 0.11 / 323.95 | 6 | 6 |
2 | 7 | 2003.68 | 40 | 14.74 | 2918 | 1720 | 1.83 / 325.67 | 6 | 17 |
3 | 13 | 1387.96 | 20 | 14.81 | 2125 | 629 | 2.46 / 326.30 | 5 | 23 |
4 | 13 | 794.36 | 20 | 14.91 | 1381 | 412 | 2.87 / 326.71 | 5 | 37 |
5 | 13 | 114.36 | 20 | 15.09 | 485 | 146 | 3.01 / 326.86 | 6 | 33 |
6 | 13 | 21.36 | 20 | 15.11 | 343 | 104 | 3.12 / 326.96 | 6 | 31 |
7 | 8 | -0.04 | 272 | 15.06 | 302 | 1237 | 4.35 / 328.20 | 6 | 145 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 16 | 15.06 | 443 | 107 | 0.11 / 319.57 | 6 | 6 |
2 | 7 | 2005.44 | 40 | 14.74 | 2913 | 1718 | 1.82 / 321.29 | 6 | 19 |
3 | 13 | 1373.96 | 20 | 14.82 | 2110 | 625 | 2.45 / 321.91 | 5 | 26 |
4 | 13 | 852.60 | 20 | 14.89 | 1466 | 437 | 2.89 / 322.35 | 5 | 30 |
5 | 13 | 116.04 | 20 | 15.09 | 487 | 147 | 3.03 / 322.50 | 5 | 31 |
6 | 13 | 42.84 | 20 | 15.10 | 374 | 113 | 3.15 / 322.61 | 6 | 32 |
7 | 8 | -0.16 | 270 | 15.05 | 303 | 1231 | 4.38 / 323.84 | 6 | 130 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 16 | 15.06 | 441 | 106 | 0.11 / 315.16 | 6 | 6 |
2 | 7 | 2011.40 | 40 | 14.73 | 2960 | 1744 | 1.85 / 316.91 | 6 | 16 |
3 | 13 | 1424.64 | 20 | 14.81 | 2173 | 644 | 2.49 / 317.55 | 5 | 29 |
4 | 13 | 820.16 | 20 | 14.91 | 1401 | 418 | 2.91 / 317.97 | 5 | 30 |
5 | 13 | 139.48 | 20 | 15.09 | 515 | 155 | 3.07 / 318.12 | 6 | 32 |
6 | 13 | 26.32 | 20 | 15.11 | 350 | 106 | 3.17 / 318.23 | 6 | 30 |
7 | 8 | -0.08 | 270 | 15.06 | 304 | 1236 | 4.41 / 319.46 | 6 | 137 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 16 | 15.06 | 441 | 106 | 0.11 / 310.83 | 6 | 6 |
2 | 7 | 2004.16 | 40 | 14.73 | 2940 | 1732 | 1.84 / 312.56 | 6 | 21 |
3 | 13 | 1330.92 | 20 | 14.83 | 2054 | 609 | 2.45 / 313.17 | 5 | 28 |
4 | 13 | 753.52 | 20 | 14.92 | 1332 | 397 | 2.85 / 313.57 | 5 | 34 |
5 | 13 | 106.96 | 20 | 15.09 | 473 | 143 | 2.99 / 313.71 | 6 | 30 |
6 | 13 | 14.20 | 20 | 15.12 | 334 | 101 | 3.09 / 313.81 | 6 | 31 |
7 | 8 | 0.00 | 270 | 15.06 | 305 | 1240 | 4.33 / 315.05 | 6 | 147 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 16 | 15.07 | 437 | 105 | 0.11 / 306.41 | 6 | 6 |
2 | 7 | 2013.40 | 40 | 14.74 | 2941 | 1734 | 1.84 / 308.15 | 6 | 17 |
3 | 13 | 1408.44 | 20 | 14.81 | 2188 | 648 | 2.49 / 308.79 | 5 | 28 |
4 | 13 | 817.56 | 20 | 14.91 | 1429 | 426 | 2.91 / 309.22 | 5 | 32 |
5 | 13 | 159.20 | 20 | 15.08 | 547 | 165 | 3.08 / 309.38 | 5 | 32 |
6 | 13 | 17.56 | 20 | 15.12 | 333 | 101 | 3.18 / 309.49 | 6 | 33 |
7 | 8 | -0.04 | 270 | 15.06 | 305 | 1240 | 4.42 / 310.73 | 6 | 138 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 16 | 15.06 | 439 | 106 | 0.11 / 302.08 | 6 | 6 |
2 | 7 | 2008.92 | 40 | 14.73 | 2947 | 1736 | 1.84 / 303.82 | 6 | 19 |
3 | 13 | 1348.36 | 20 | 14.83 | 2085 | 618 | 2.46 / 304.44 | 5 | 28 |
4 | 13 | 794.40 | 20 | 14.92 | 1387 | 414 | 2.87 / 304.85 | 5 | 34 |
5 | 13 | 73.44 | 20 | 15.11 | 422 | 128 | 3.00 / 304.98 | 6 | 30 |
6 | 8 | 0.08 | 289 | 15.07 | 305 | 1328 | 4.33 / 306.31 | 6 | 139 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 16 | 15.07 | 438 | 106 | 0.11 / 297.76 | 6 | 6 |
2 | 7 | 2007.08 | 40 | 14.75 | 2911 | 1717 | 1.82 / 299.47 | 6 | 18 |
3 | 13 | 1334.72 | 20 | 14.83 | 2078 | 616 | 2.44 / 300.09 | 5 | 30 |
4 | 13 | 782.52 | 20 | 14.92 | 1370 | 409 | 2.85 / 300.50 | 5 | 36 |
5 | 13 | 98.04 | 20 | 15.10 | 464 | 140 | 2.99 / 300.64 | 5 | 33 |
6 | 8 | 0.04 | 289 | 15.07 | 307 | 1337 | 4.33 / 301.98 | 6 | 145 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 16 | 15.06 | 447 | 108 | 0.11 / 293.35 | 6 | 6 |
2 | 7 | 2010.12 | 40 | 14.74 | 2952 | 1740 | 1.85 / 295.09 | 6 | 21 |
3 | 13 | 1455.12 | 20 | 14.81 | 2229 | 660 | 2.51 / 295.75 | 5 | 27 |
4 | 13 | 849.24 | 20 | 14.91 | 1447 | 431 | 2.94 / 296.18 | 5 | 31 |
5 | 13 | 125.88 | 20 | 15.10 | 500 | 151 | 3.09 / 296.34 | 5 | 33 |
6 | 8 | -0.04 | 289 | 15.07 | 302 | 1315 | 4.41 / 297.65 | 6 | 130 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 16 | 15.06 | 440 | 106 | 0.11 / 288.97 | 6 | 6 |
2 | 7 | 2011.96 | 40 | 14.74 | 2970 | 1751 | 1.86 / 290.72 | 6 | 22 |
3 | 13 | 1353.52 | 20 | 14.83 | 2117 | 628 | 2.49 / 291.35 | 5 | 28 |
4 | 13 | 763.48 | 20 | 14.93 | 1355 | 405 | 2.89 / 291.75 | 5 | 36 |
5 | 13 | 131.80 | 20 | 15.09 | 518 | 156 | 3.05 / 291.91 | 5 | 35 |
6 | 8 | -0.12 | 287 | 15.07 | 309 | 1336 | 4.38 / 293.24 | 6 | 133 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 16 | 15.06 | 438 | 106 | 0.11 / 284.46 | 6 | 6 |
2 | 7 | 2006.64 | 41 | 14.73 | 2978 | 1799 | 1.90 / 286.26 | 6 | 21 |
3 | 13 | 1424.00 | 20 | 14.82 | 2177 | 645 | 2.55 / 286.91 | 5 | 27 |
4 | 13 | 813.12 | 20 | 14.91 | 1415 | 422 | 2.97 / 287.33 | 5 | 34 |
5 | 13 | 118.44 | 20 | 15.10 | 496 | 150 | 3.12 / 287.48 | 5 | 37 |
6 | 8 | 0.08 | 289 | 15.07 | 318 | 1385 | 4.51 / 288.86 | 6 | 148 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 16 | 15.08 | 438 | 106 | 0.11 / 280.01 | 6 | 6 |
2 | 7 | 2010.96 | 40 | 14.74 | 2970 | 1751 | 1.86 / 281.76 | 6 | 20 |
3 | 13 | 1427.04 | 20 | 14.82 | 2209 | 655 | 2.51 / 282.41 | 5 | 29 |
4 | 13 | 810.44 | 20 | 14.92 | 1415 | 422 | 2.93 / 282.84 | 5 | 34 |
5 | 13 | 141.64 | 20 | 15.10 | 529 | 160 | 3.09 / 283.00 | 5 | 35 |
6 | 8 | -0.08 | 289 | 15.07 | 312 | 1359 | 4.45 / 284.36 | 6 | 142 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 16 | 15.08 | 454 | 110 | 0.11 / 275.61 | 6 | 6 |
2 | 7 | 2006.52 | 40 | 14.74 | 2970 | 1751 | 1.86 / 277.36 | 6 | 20 |
3 | 13 | 1324.16 | 20 | 14.84 | 2063 | 612 | 2.47 / 277.98 | 5 | 27 |
4 | 13 | 906.52 | 20 | 14.90 | 1534 | 457 | 2.93 / 278.43 | 5 | 35 |
5 | 13 | 128.08 | 20 | 15.11 | 508 | 154 | 3.08 / 278.59 | 6 | 31 |
6 | 8 | -0.04 | 287 | 15.08 | 304 | 1316 | 4.40 / 279.90 | 6 | 133 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 16 | 15.08 | 442 | 107 | 0.11 / 271.21 | 6 | 6 |
2 | 7 | 2008.48 | 41 | 14.74 | 2954 | 1785 | 1.89 / 272.99 | 6 | 23 |
3 | 13 | 1303.80 | 20 | 14.85 | 2032 | 604 | 2.50 / 273.60 | 5 | 26 |
4 | 13 | 769.72 | 20 | 14.94 | 1354 | 405 | 2.90 / 274.00 | 5 | 33 |
5 | 13 | 188.24 | 20 | 15.10 | 580 | 175 | 3.08 / 274.18 | 6 | 32 |
6 | 13 | 66.12 | 20 | 15.13 | 403 | 122 | 3.20 / 274.30 | 6 | 27 |
7 | 8 | 0.04 | 270 | 15.09 | 296 | 1206 | 4.40 / 275.50 | 6 | 144 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 16 | 15.08 | 442 | 107 | 0.11 / 266.80 | 6 | 6 |
2 | 7 | 2011.80 | 40 | 14.74 | 2942 | 1735 | 1.84 / 268.54 | 6 | 20 |
3 | 13 | 1441.32 | 20 | 14.82 | 2211 | 655 | 2.50 / 269.19 | 5 | 29 |
4 | 13 | 818.36 | 20 | 14.93 | 1421 | 424 | 2.92 / 269.61 | 5 | 33 |
5 | 13 | 159.64 | 20 | 15.11 | 540 | 163 | 3.08 / 269.78 | 6 | 33 |
6 | 13 | 18.44 | 20 | 15.14 | 333 | 101 | 3.18 / 269.88 | 6 | 30 |
7 | 8 | 0.08 | 270 | 15.09 | 300 | 1222 | 4.41 / 271.10 | 6 | 145 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 16 | 15.08 | 443 | 107 | 0.11 / 262.38 | 6 | 6 |
2 | 7 | 2010.36 | 40 | 14.74 | 2955 | 1742 | 1.85 / 264.12 | 6 | 18 |
3 | 13 | 1458.84 | 20 | 14.82 | 2243 | 665 | 2.51 / 264.78 | 5 | 27 |
4 | 13 | 844.36 | 20 | 14.93 | 1452 | 434 | 2.95 / 265.22 | 5 | 33 |
5 | 13 | 182.72 | 20 | 15.11 | 572 | 173 | 3.12 / 265.39 | 6 | 30 |
6 | 8 | 0.12 | 289 | 15.10 | 299 | 1305 | 4.43 / 266.69 | 6 | 134 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 16 | 15.09 | 444 | 107 | 0.11 / 258.00 | 6 | 6 |
2 | 7 | 2010.00 | 40 | 14.74 | 2973 | 1753 | 1.86 / 259.75 | 6 | 20 |
3 | 13 | 1415.08 | 20 | 14.83 | 2177 | 646 | 2.51 / 260.39 | 5 | 27 |
4 | 13 | 774.68 | 20 | 14.95 | 1370 | 410 | 2.92 / 260.80 | 5 | 36 |
5 | 13 | 130.00 | 20 | 15.12 | 498 | 151 | 3.07 / 260.96 | 6 | 31 |
6 | 8 | 0.04 | 289 | 15.10 | 301 | 1314 | 4.38 / 262.27 | 6 | 151 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 16 | 15.10 | 444 | 107 | 0.11 / 253.68 | 6 | 6 |
2 | 7 | 2004.60 | 40 | 14.75 | 2920 | 1723 | 1.83 / 255.40 | 6 | 18 |
3 | 13 | 1335.20 | 20 | 14.85 | 2073 | 616 | 2.45 / 256.02 | 5 | 30 |
4 | 13 | 781.76 | 20 | 14.95 | 1358 | 406 | 2.85 / 256.42 | 5 | 34 |
5 | 13 | 126.08 | 20 | 15.12 | 493 | 149 | 3.00 / 256.57 | 6 | 31 |
6 | 13 | 23.76 | 20 | 15.15 | 342 | 104 | 3.10 / 256.68 | 6 | 30 |
7 | 8 | 0.00 | 267 | 15.09 | 301 | 1213 | 4.32 / 257.89 | 6 | 132 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 16 | 15.09 | 447 | 108 | 0.11 / 249.26 | 6 | 6 |
2 | 7 | 2008.72 | 40 | 14.76 | 2951 | 1742 | 1.85 / 251.00 | 6 | 21 |
3 | 13 | 1422.44 | 20 | 14.84 | 2181 | 647 | 2.50 / 251.64 | 5 | 27 |
4 | 13 | 823.32 | 20 | 14.94 | 1427 | 426 | 2.92 / 252.07 | 5 | 35 |
5 | 13 | 210.60 | 20 | 15.10 | 606 | 183 | 3.11 / 252.25 | 6 | 31 |
6 | 13 | 26.52 | 20 | 15.15 | 337 | 102 | 3.21 / 252.36 | 6 | 26 |
7 | 8 | 0.04 | 272 | 15.10 | 296 | 1216 | 4.42 / 253.57 | 6 | 142 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 16 | 15.09 | 436 | 105 | 0.11 / 244.90 | 6 | 6 |
2 | 7 | 2008.80 | 40 | 14.75 | 2940 | 1735 | 1.84 / 246.63 | 6 | 20 |
3 | 13 | 1395.68 | 20 | 14.85 | 2153 | 639 | 2.48 / 247.27 | 5 | 26 |
4 | 13 | 765.72 | 20 | 14.95 | 1361 | 407 | 2.89 / 247.68 | 5 | 35 |
5 | 13 | 151.04 | 20 | 15.12 | 534 | 161 | 3.05 / 247.84 | 6 | 32 |
6 | 8 | 0.12 | 287 | 15.10 | 302 | 1309 | 4.36 / 249.15 | 6 | 132 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 16 | 15.10 | 435 | 105 | 0.11 / 240.54 | 6 | 6 |
2 | 7 | 2012.04 | 40 | 14.75 | 2964 | 1749 | 1.85 / 242.29 | 6 | 21 |
3 | 13 | 1382.56 | 20 | 14.85 | 2145 | 637 | 2.49 / 242.93 | 5 | 27 |
4 | 13 | 743.88 | 20 | 14.96 | 1335 | 399 | 2.89 / 243.33 | 5 | 35 |
5 | 13 | 131.08 | 20 | 15.13 | 502 | 152 | 3.04 / 243.48 | 6 | 31 |
6 | 8 | -0.04 | 287 | 15.10 | 303 | 1313 | 4.36 / 244.79 | 6 | 145 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 16 | 15.11 | 463 | 112 | 0.11 / 236.19 | 6 | 6 |
2 | 7 | 2004.04 | 40 | 14.76 | 2962 | 1749 | 1.86 / 237.94 | 6 | 21 |
3 | 13 | 1411.00 | 20 | 14.84 | 2201 | 653 | 2.51 / 238.59 | 5 | 28 |
4 | 13 | 783.00 | 20 | 14.96 | 1383 | 414 | 2.93 / 239.01 | 5 | 34 |
5 | 13 | 139.00 | 20 | 15.14 | 505 | 153 | 3.08 / 239.16 | 6 | 28 |
6 | 8 | 0.04 | 289 | 15.12 | 292 | 1276 | 4.36 / 240.44 | 6 | 139 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 16 | 15.11 | 446 | 108 | 0.11 / 231.76 | 6 | 6 |
2 | 7 | 2004.60 | 41 | 14.76 | 2925 | 1770 | 1.88 / 233.53 | 6 | 20 |
3 | 13 | 1403.36 | 20 | 14.85 | 2164 | 643 | 2.52 / 234.17 | 5 | 26 |
4 | 13 | 784.80 | 20 | 14.97 | 1376 | 412 | 2.93 / 234.58 | 5 | 33 |
5 | 13 | 153.08 | 20 | 15.14 | 525 | 159 | 3.09 / 234.74 | 6 | 26 |
6 | 13 | 82.80 | 20 | 15.15 | 420 | 127 | 3.22 / 234.87 | 6 | 24 |
7 | 8 | 0.16 | 270 | 15.12 | 296 | 1208 | 4.43 / 236.08 | 6 | 143 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 16 | 15.09 | 449 | 108 | 0.11 / 227.30 | 6 | 6 |
2 | 7 | 2005.80 | 40 | 14.77 | 2938 | 1736 | 1.84 / 229.03 | 6 | 21 |
3 | 13 | 1424.04 | 20 | 14.86 | 2177 | 647 | 2.49 / 229.68 | 5 | 27 |
4 | 13 | 902.68 | 20 | 14.94 | 1531 | 457 | 2.95 / 230.14 | 5 | 35 |
5 | 13 | 255.72 | 20 | 15.11 | 670 | 202 | 3.15 / 230.34 | 6 | 31 |
6 | 13 | 23.52 | 20 | 15.17 | 338 | 103 | 3.25 / 230.44 | 6 | 25 |
7 | 8 | 0.20 | 270 | 15.12 | 296 | 1208 | 4.46 / 231.65 | 6 | 135 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 16 | 15.10 | 442 | 107 | 0.11 / 222.86 | 6 | 7 |
2 | 7 | 2009.28 | 40 | 14.78 | 2903 | 1716 | 1.82 / 224.58 | 7 | 18 |
3 | 13 | 1419.96 | 20 | 14.86 | 2180 | 648 | 2.47 / 225.23 | 5 | 26 |
4 | 13 | 858.44 | 20 | 14.95 | 1477 | 442 | 2.91 / 225.67 | 5 | 34 |
5 | 13 | 211.88 | 20 | 15.12 | 615 | 186 | 3.10 / 225.85 | 5 | 35 |
6 | 8 | 0.04 | 289 | 15.11 | 306 | 1336 | 4.43 / 227.19 | 6 | 139 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 16 | 15.11 | 440 | 106 | 0.11 / 218.45 | 6 | 6 |
2 | 7 | 2008.08 | 40 | 14.77 | 2918 | 1724 | 1.83 / 220.18 | 6 | 21 |
3 | 13 | 1393.80 | 20 | 14.86 | 2156 | 641 | 2.47 / 220.82 | 5 | 27 |
4 | 13 | 789.24 | 20 | 14.96 | 1400 | 419 | 2.89 / 221.24 | 5 | 36 |
5 | 13 | 146.88 | 20 | 15.13 | 538 | 163 | 3.05 / 221.40 | 5 | 36 |
6 | 8 | -0.08 | 289 | 15.11 | 310 | 1354 | 4.41 / 222.75 | 6 | 145 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 16 | 15.12 | 449 | 109 | 0.11 / 213.98 | 6 | 6 |
2 | 7 | 2010.24 | 41 | 14.77 | 2929 | 1774 | 1.88 / 215.75 | 6 | 20 |
3 | 13 | 1472.88 | 20 | 14.84 | 2254 | 669 | 2.55 / 216.42 | 5 | 26 |
4 | 13 | 806.12 | 20 | 14.97 | 1398 | 419 | 2.97 / 216.84 | 5 | 34 |
5 | 13 | 181.92 | 20 | 15.14 | 572 | 173 | 3.14 / 217.01 | 6 | 32 |
6 | 13 | 25.72 | 20 | 15.17 | 344 | 104 | 3.25 / 217.12 | 6 | 29 |
7 | 8 | 0.04 | 270 | 15.12 | 301 | 1229 | 4.48 / 218.35 | 6 | 149 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 16 | 15.11 | 448 | 108 | 0.11 / 209.54 | 6 | 6 |
2 | 7 | 2009.48 | 40 | 14.76 | 2983 | 1761 | 1.87 / 211.30 | 6 | 21 |
3 | 13 | 1476.32 | 20 | 14.85 | 2256 | 670 | 2.54 / 211.97 | 5 | 27 |
4 | 13 | 787.60 | 20 | 14.98 | 1382 | 414 | 2.95 / 212.38 | 5 | 34 |
5 | 13 | 141.36 | 20 | 15.16 | 512 | 155 | 3.11 / 212.54 | 6 | 30 |
6 | 13 | 40.76 | 20 | 15.18 | 368 | 112 | 3.22 / 212.65 | 6 | 27 |
7 | 8 | 0.04 | 270 | 15.13 | 299 | 1221 | 4.44 / 213.87 | 6 | 138 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 16 | 15.12 | 452 | 109 | 0.11 / 205.08 | 6 | 6 |
2 | 7 | 2012.52 | 40 | 14.78 | 2949 | 1743 | 1.85 / 206.82 | 6 | 21 |
3 | 13 | 1434.72 | 20 | 14.86 | 2209 | 657 | 2.51 / 207.48 | 5 | 29 |
4 | 13 | 786.92 | 20 | 14.98 | 1390 | 416 | 2.93 / 207.90 | 5 | 35 |
5 | 13 | 146.92 | 20 | 15.15 | 534 | 162 | 3.09 / 208.06 | 6 | 33 |
6 | 13 | 15.72 | 20 | 15.18 | 338 | 103 | 3.19 / 208.16 | 6 | 32 |
7 | 8 | -0.16 | 270 | 15.12 | 311 | 1270 | 4.46 / 209.43 | 6 | 148 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 16 | 15.11 | 452 | 109 | 0.11 / 200.60 | 6 | 6 |
2 | 7 | 2010.80 | 41 | 14.78 | 2942 | 1783 | 1.89 / 202.39 | 6 | 21 |
3 | 13 | 1344.44 | 20 | 14.88 | 2082 | 620 | 2.51 / 203.01 | 5 | 27 |
4 | 13 | 851.60 | 20 | 14.96 | 1472 | 440 | 2.95 / 203.45 | 5 | 34 |
5 | 13 | 131.04 | 20 | 15.15 | 514 | 156 | 3.11 / 203.60 | 6 | 34 |
6 | 8 | -0.08 | 287 | 15.13 | 315 | 1368 | 4.48 / 204.97 | 6 | 136 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 16 | 15.12 | 456 | 110 | 0.11 / 196.17 | 6 | 7 |
2 | 7 | 2003.68 | 40 | 14.77 | 2953 | 1745 | 1.85 / 197.91 | 7 | 20 |
3 | 13 | 1418.32 | 20 | 14.87 | 2201 | 655 | 2.51 / 198.57 | 5 | 29 |
4 | 13 | 805.88 | 20 | 14.97 | 1415 | 424 | 2.93 / 198.99 | 5 | 33 |
5 | 13 | 113.76 | 20 | 15.16 | 483 | 146 | 3.08 / 199.14 | 6 | 33 |
6 | 8 | 0.20 | 287 | 15.13 | 312 | 1355 | 4.43 / 200.49 | 6 | 145 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 16 | 15.12 | 456 | 110 | 0.11 / 191.80 | 6 | 6 |
2 | 7 | 2004.92 | 40 | 14.77 | 2972 | 1756 | 1.87 / 193.56 | 6 | 20 |
3 | 13 | 1363.32 | 20 | 14.89 | 2114 | 630 | 2.50 / 194.19 | 5 | 27 |
4 | 13 | 707.64 | 20 | 15.01 | 1271 | 382 | 2.88 / 194.57 | 5 | 34 |
5 | 13 | 99.64 | 20 | 15.17 | 469 | 142 | 3.02 / 194.71 | 6 | 33 |
6 | 8 | -0.12 | 285 | 15.13 | 313 | 1350 | 4.37 / 196.06 | 6 | 135 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 16 | 15.12 | 446 | 108 | 0.11 / 187.36 | 6 | 6 |
2 | 7 | 2011.68 | 41 | 14.77 | 2960 | 1792 | 1.90 / 189.15 | 6 | 18 |
3 | 13 | 1382.24 | 20 | 14.88 | 2138 | 636 | 2.54 / 189.79 | 5 | 25 |
4 | 13 | 746.24 | 20 | 15.00 | 1324 | 397 | 2.93 / 190.18 | 5 | 33 |
5 | 13 | 99.64 | 20 | 15.17 | 469 | 142 | 3.08 / 190.33 | 6 | 31 |
6 | 8 | 0.12 | 287 | 15.14 | 314 | 1364 | 4.44 / 191.69 | 6 | 139 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 16 | 15.13 | 443 | 107 | 0.11 / 182.93 | 6 | 6 |
2 | 7 | 2012.52 | 40 | 14.78 | 2951 | 1745 | 1.85 / 184.67 | 6 | 16 |
3 | 13 | 1396.88 | 20 | 14.88 | 2131 | 634 | 2.49 / 185.31 | 5 | 22 |
4 | 13 | 828.04 | 20 | 14.98 | 1435 | 430 | 2.92 / 185.74 | 5 | 29 |
5 | 13 | 170.84 | 20 | 15.15 | 561 | 170 | 3.09 / 185.91 | 5 | 31 |
6 | 8 | 0.08 | 289 | 15.14 | 307 | 1343 | 4.43 / 187.25 | 6 | 149 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 16 | 15.13 | 456 | 110 | 0.11 / 178.51 | 6 | 6 |
2 | 7 | 2010.44 | 41 | 14.78 | 2954 | 1790 | 1.90 / 180.30 | 6 | 17 |
3 | 13 | 1432.60 | 20 | 14.88 | 2201 | 655 | 2.56 / 180.95 | 5 | 24 |
4 | 13 | 750.32 | 20 | 15.00 | 1338 | 401 | 2.96 / 181.35 | 5 | 33 |
5 | 13 | 96.84 | 20 | 15.18 | 459 | 139 | 3.10 / 181.49 | 6 | 30 |
6 | 8 | 0.00 | 285 | 15.14 | 308 | 1329 | 4.43 / 182.82 | 6 | 132 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 16 | 15.14 | 445 | 108 | 0.11 / 174.11 | 6 | 6 |
2 | 7 | 2012.84 | 40 | 14.79 | 2948 | 1744 | 1.85 / 175.85 | 6 | 17 |
3 | 13 | 1434.96 | 20 | 14.87 | 2192 | 652 | 2.50 / 176.51 | 5 | 23 |
4 | 13 | 768.80 | 20 | 15.00 | 1354 | 406 | 2.91 / 176.91 | 5 | 31 |
5 | 13 | 122.56 | 20 | 15.18 | 494 | 150 | 3.06 / 177.06 | 6 | 31 |
6 | 8 | 0.00 | 287 | 15.14 | 307 | 1334 | 4.39 / 178.40 | 6 | 131 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 16 | 15.14 | 446 | 108 | 0.11 / 169.68 | 6 | 6 |
2 | 7 | 2009.16 | 41 | 14.78 | 2946 | 1785 | 1.89 / 171.46 | 6 | 18 |
3 | 13 | 1413.68 | 20 | 14.89 | 2166 | 645 | 2.54 / 172.11 | 5 | 24 |
4 | 13 | 781.08 | 20 | 15.00 | 1358 | 407 | 2.95 / 172.52 | 5 | 32 |
5 | 13 | 102.40 | 20 | 15.19 | 464 | 141 | 3.09 / 172.66 | 6 | 29 |
6 | 8 | -0.04 | 289 | 15.15 | 307 | 1344 | 4.43 / 174.00 | 6 | 159 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 16 | 15.15 | 451 | 109 | 0.11 / 165.33 | 6 | 6 |
2 | 7 | 2009.08 | 40 | 14.78 | 2941 | 1739 | 1.85 / 167.07 | 6 | 17 |
3 | 13 | 1403.64 | 20 | 14.89 | 2154 | 641 | 2.49 / 167.71 | 5 | 24 |
4 | 13 | 760.32 | 20 | 15.01 | 1343 | 403 | 2.89 / 168.12 | 5 | 32 |
5 | 13 | 109.48 | 20 | 15.19 | 468 | 142 | 3.03 / 168.26 | 6 | 28 |
6 | 8 | 0.12 | 289 | 15.15 | 300 | 1314 | 4.35 / 169.57 | 6 | 149 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 16 | 15.15 | 457 | 111 | 0.11 / 161.03 | 6 | 6 |
2 | 7 | 2012.88 | 40 | 14.79 | 2922 | 1729 | 1.84 / 162.76 | 6 | 17 |
3 | 13 | 1306.48 | 20 | 14.92 | 2024 | 604 | 2.44 / 163.36 | 5 | 26 |
4 | 13 | 754.72 | 20 | 15.02 | 1325 | 398 | 2.84 / 163.76 | 5 | 31 |
5 | 13 | 177.24 | 20 | 15.18 | 567 | 172 | 3.01 / 163.93 | 6 | 27 |
6 | 8 | 0.12 | 289 | 15.17 | 294 | 1289 | 4.30 / 165.22 | 6 | 153 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 16 | 15.15 | 453 | 110 | 0.11 / 156.63 | 6 | 6 |
2 | 7 | 2010.84 | 40 | 14.79 | 2956 | 1749 | 1.86 / 158.38 | 6 | 18 |
3 | 13 | 1372.20 | 20 | 14.90 | 2106 | 628 | 2.49 / 159.01 | 5 | 25 |
4 | 13 | 804.72 | 20 | 15.00 | 1409 | 423 | 2.91 / 159.43 | 5 | 32 |
5 | 13 | 173.96 | 20 | 15.18 | 568 | 172 | 3.08 / 159.61 | 6 | 28 |
6 | 8 | 0.00 | 289 | 15.16 | 300 | 1314 | 4.40 / 160.92 | 6 | 148 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 15 | 15.15 | 446 | 101 | 0.10 / 152.22 | 6 | 6 |
2 | 7 | 2009.56 | 40 | 14.80 | 2968 | 1757 | 1.86 / 153.98 | 6 | 18 |
3 | 13 | 1410.40 | 20 | 14.90 | 2146 | 640 | 2.50 / 154.62 | 5 | 24 |
4 | 13 | 776.80 | 20 | 15.02 | 1366 | 410 | 2.91 / 155.03 | 5 | 31 |
5 | 13 | 160.20 | 20 | 15.18 | 550 | 167 | 3.08 / 155.20 | 6 | 30 |
6 | 8 | 0.04 | 289 | 15.17 | 303 | 1328 | 4.40 / 156.52 | 6 | 140 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 15 | 15.15 | 451 | 102 | 0.10 / 147.89 | 6 | 6 |
2 | 7 | 2009.20 | 40 | 14.80 | 2912 | 1724 | 1.83 / 149.61 | 6 | 17 |
3 | 13 | 1320.32 | 20 | 14.92 | 2066 | 616 | 2.44 / 150.23 | 5 | 26 |
4 | 13 | 759.12 | 20 | 15.02 | 1348 | 405 | 2.85 / 150.64 | 5 | 32 |
5 | 13 | 108.48 | 20 | 15.19 | 476 | 145 | 2.99 / 150.78 | 5 | 32 |
6 | 8 | 0.08 | 287 | 15.16 | 308 | 1340 | 4.33 / 152.12 | 6 | 136 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 15 | 15.16 | 449 | 102 | 0.10 / 143.44 | 6 | 6 |
2 | 7 | 2007.76 | 40 | 14.80 | 2931 | 1735 | 1.84 / 145.18 | 6 | 17 |
3 | 13 | 1469.28 | 20 | 14.89 | 2250 | 670 | 2.51 / 145.85 | 5 | 24 |
4 | 13 | 809.08 | 20 | 15.01 | 1411 | 424 | 2.93 / 146.27 | 5 | 32 |
5 | 13 | 155.60 | 20 | 15.17 | 553 | 168 | 3.10 / 146.44 | 5 | 36 |
6 | 8 | -0.08 | 289 | 15.16 | 308 | 1349 | 4.45 / 147.79 | 6 | 140 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 15 | 15.17 | 459 | 104 | 0.10 / 139.04 | 6 | 6 |
2 | 7 | 2012.16 | 40 | 14.80 | 2967 | 1756 | 1.86 / 140.80 | 6 | 17 |
3 | 13 | 1383.48 | 20 | 14.91 | 2124 | 633 | 2.49 / 141.43 | 5 | 26 |
4 | 13 | 779.08 | 20 | 15.03 | 1365 | 410 | 2.90 / 141.84 | 5 | 30 |
5 | 13 | 164.08 | 20 | 15.19 | 543 | 165 | 3.07 / 142.00 | 6 | 29 |
6 | 13 | 49.96 | 20 | 15.22 | 378 | 115 | 3.18 / 142.12 | 6 | 26 |
7 | 8 | 0.16 | 270 | 15.17 | 298 | 1221 | 4.41 / 143.34 | 6 | 150 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 16 | 15.17 | 443 | 108 | 0.11 / 134.60 | 6 | 6 |
2 | 7 | 2011.68 | 40 | 14.80 | 2964 | 1755 | 1.86 / 136.36 | 6 | 18 |
3 | 13 | 1445.76 | 20 | 14.90 | 2208 | 658 | 2.52 / 137.01 | 5 | 25 |
4 | 13 | 788.92 | 20 | 15.03 | 1371 | 412 | 2.93 / 137.43 | 5 | 31 |
5 | 13 | 163.20 | 20 | 15.19 | 552 | 168 | 3.10 / 137.59 | 6 | 29 |
6 | 13 | 54.44 | 20 | 15.22 | 386 | 117 | 3.22 / 137.71 | 6 | 26 |
7 | 8 | -0.04 | 267 | 15.18 | 302 | 1224 | 4.44 / 138.94 | 6 | 138 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 16 | 15.18 | 445 | 108 | 0.11 / 130.23 | 6 | 6 |
2 | 7 | 2009.48 | 40 | 14.82 | 2913 | 1727 | 1.83 / 131.96 | 6 | 15 |
3 | 13 | 1405.80 | 20 | 14.92 | 2141 | 639 | 2.47 / 132.60 | 5 | 22 |
4 | 13 | 764.56 | 20 | 15.03 | 1358 | 408 | 2.88 / 133.01 | 5 | 29 |
5 | 13 | 114.48 | 20 | 15.21 | 481 | 146 | 3.03 / 133.15 | 6 | 28 |
6 | 13 | 20.28 | 20 | 15.23 | 340 | 104 | 3.13 / 133.26 | 6 | 27 |
7 | 8 | 0.16 | 267 | 15.18 | 305 | 1236 | 4.37 / 134.49 | 6 | 144 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 15 | 15.18 | 450 | 102 | 0.10 / 125.84 | 6 | 6 |
2 | 7 | 2009.08 | 40 | 14.82 | 2921 | 1732 | 1.83 / 127.57 | 6 | 14 |
3 | 13 | 1414.60 | 20 | 14.93 | 2142 | 640 | 2.47 / 128.21 | 5 | 20 |
4 | 13 | 761.56 | 20 | 15.04 | 1348 | 405 | 2.88 / 128.61 | 5 | 27 |
5 | 13 | 157.28 | 20 | 15.21 | 543 | 165 | 3.04 / 128.78 | 6 | 25 |
6 | 13 | 51.68 | 20 | 15.23 | 381 | 116 | 3.16 / 128.90 | 6 | 22 |
7 | 8 | 0.04 | 270 | 15.18 | 300 | 1230 | 4.39 / 130.13 | 6 | 135 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 15 | 15.18 | 443 | 101 | 0.10 / 121.42 | 6 | 6 |
2 | 7 | 2003.40 | 40 | 14.82 | 2944 | 1745 | 1.85 / 123.17 | 6 | 16 |
3 | 13 | 1440.64 | 20 | 14.92 | 2178 | 650 | 2.50 / 123.82 | 5 | 23 |
4 | 13 | 802.44 | 20 | 15.03 | 1397 | 420 | 2.92 / 124.24 | 5 | 31 |
5 | 13 | 153.00 | 20 | 15.21 | 530 | 161 | 3.08 / 124.40 | 6 | 28 |
6 | 13 | 44.32 | 20 | 15.23 | 370 | 113 | 3.19 / 124.51 | 6 | 25 |
7 | 8 | 0.08 | 270 | 15.19 | 299 | 1226 | 4.42 / 125.74 | 6 | 134 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 15 | 15.17 | 456 | 104 | 0.10 / 116.99 | 6 | 6 |
2 | 7 | 2008.76 | 40 | 14.82 | 2943 | 1745 | 1.85 / 118.74 | 6 | 17 |
3 | 13 | 1459.48 | 20 | 14.91 | 2228 | 664 | 2.51 / 119.40 | 5 | 24 |
4 | 13 | 789.36 | 20 | 15.04 | 1382 | 416 | 2.93 / 119.82 | 5 | 31 |
5 | 13 | 138.76 | 20 | 15.21 | 511 | 155 | 3.08 / 119.97 | 6 | 29 |
6 | 13 | 30.80 | 20 | 15.24 | 352 | 107 | 3.19 / 120.08 | 6 | 27 |
7 | 8 | 0.04 | 270 | 15.19 | 302 | 1239 | 4.43 / 121.32 | 6 | 138 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 15 | 15.18 | 447 | 102 | 0.10 / 112.57 | 6 | 6 |
2 | 7 | 2003.04 | 40 | 14.83 | 2903 | 1722 | 1.82 / 114.29 | 6 | 17 |
3 | 13 | 1409.12 | 20 | 14.93 | 2157 | 644 | 2.47 / 114.94 | 5 | 24 |
4 | 13 | 767.48 | 20 | 15.04 | 1360 | 409 | 2.88 / 115.35 | 5 | 31 |
5 | 13 | 154.88 | 20 | 15.21 | 543 | 165 | 3.04 / 115.51 | 6 | 31 |
6 | 13 | 36.72 | 20 | 15.24 | 370 | 113 | 3.15 / 115.62 | 6 | 28 |
7 | 8 | 0.00 | 270 | 15.18 | 309 | 1266 | 4.42 / 116.89 | 6 | 140 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 15 | 15.19 | 445 | 101 | 0.10 / 108.15 | 6 | 6 |
2 | 7 | 2006.88 | 40 | 14.82 | 2972 | 1762 | 1.86 / 109.92 | 6 | 16 |
3 | 13 | 1363.92 | 20 | 14.94 | 2119 | 633 | 2.50 / 110.55 | 5 | 25 |
4 | 13 | 765.84 | 20 | 15.05 | 1350 | 406 | 2.90 / 110.96 | 5 | 31 |
5 | 13 | 102.56 | 20 | 15.23 | 472 | 144 | 3.05 / 111.10 | 6 | 30 |
6 | 13 | 31.12 | 20 | 15.24 | 364 | 111 | 3.16 / 111.21 | 6 | 29 |
7 | 8 | -0.08 | 267 | 15.19 | 310 | 1257 | 4.41 / 112.47 | 6 | 141 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 15 | 15.21 | 442 | 101 | 0.10 / 103.79 | 6 | 6 |
2 | 7 | 2006.96 | 40 | 14.83 | 2931 | 1739 | 1.84 / 105.53 | 6 | 17 |
3 | 13 | 1398.84 | 20 | 14.93 | 2175 | 649 | 2.49 / 106.18 | 5 | 25 |
4 | 13 | 750.00 | 20 | 15.06 | 1325 | 399 | 2.89 / 106.57 | 5 | 31 |
5 | 13 | 96.52 | 20 | 15.23 | 453 | 138 | 3.03 / 106.71 | 6 | 29 |
6 | 13 | 17.96 | 20 | 15.25 | 342 | 104 | 3.13 / 106.82 | 6 | 28 |
7 | 8 | 0.00 | 265 | 15.20 | 307 | 1237 | 4.37 / 108.05 | 6 | 134 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 15 | 15.20 | 432 | 98 | 0.10 / 99.37 | 6 | 6 |
2 | 7 | 2011.60 | 40 | 14.84 | 2942 | 1746 | 1.84 / 101.12 | 6 | 17 |
3 | 13 | 1442.20 | 20 | 14.94 | 2208 | 660 | 2.50 / 101.78 | 5 | 23 |
4 | 13 | 796.32 | 20 | 15.05 | 1382 | 416 | 2.92 / 102.19 | 5 | 30 |
5 | 13 | 174.48 | 20 | 15.22 | 558 | 170 | 3.09 / 102.36 | 6 | 27 |
6 | 13 | 72.72 | 20 | 15.25 | 410 | 125 | 3.22 / 102.49 | 6 | 23 |
7 | 8 | 0.04 | 270 | 15.21 | 292 | 1199 | 4.41 / 103.69 | 6 | 138 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 15 | 15.21 | 434 | 99 | 0.10 / 94.96 | 6 | 6 |
2 | 7 | 2012.60 | 40 | 14.83 | 2966 | 1759 | 1.86 / 96.72 | 6 | 17 |
3 | 13 | 1345.00 | 20 | 14.95 | 2084 | 623 | 2.48 / 97.35 | 5 | 25 |
4 | 13 | 782.40 | 20 | 15.05 | 1381 | 416 | 2.90 / 97.76 | 5 | 32 |
5 | 13 | 186.12 | 20 | 15.22 | 581 | 177 | 3.07 / 97.94 | 6 | 26 |
6 | 13 | 71.16 | 20 | 15.24 | 407 | 124 | 3.20 / 98.06 | 6 | 24 |
7 | 8 | 0.04 | 267 | 15.21 | 298 | 1210 | 4.41 / 99.27 | 6 | 130 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 15 | 15.21 | 430 | 98 | 0.10 / 90.54 | 6 | 6 |
2 | 7 | 2009.32 | 40 | 14.84 | 2932 | 1740 | 1.84 / 92.28 | 6 | 17 |
3 | 13 | 1409.20 | 20 | 14.95 | 2158 | 645 | 2.48 / 92.93 | 5 | 25 |
4 | 13 | 803.80 | 20 | 15.05 | 1401 | 422 | 2.91 / 93.35 | 5 | 30 |
5 | 13 | 186.20 | 20 | 15.23 | 568 | 173 | 3.08 / 93.52 | 6 | 24 |
6 | 13 | 78.16 | 20 | 15.25 | 415 | 127 | 3.21 / 93.65 | 6 | 21 |
7 | 8 | 0.04 | 270 | 15.22 | 295 | 1212 | 4.42 / 94.86 | 6 | 147 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 15 | 15.22 | 437 | 100 | 0.10 / 86.07 | 6 | 6 |
2 | 7 | 2009.48 | 41 | 14.84 | 2944 | 1791 | 1.89 / 87.86 | 6 | 18 |
3 | 13 | 1369.56 | 20 | 14.95 | 2129 | 637 | 2.53 / 88.49 | 5 | 25 |
4 | 13 | 801.32 | 20 | 15.06 | 1396 | 420 | 2.95 / 88.91 | 5 | 30 |
5 | 13 | 212.76 | 20 | 15.23 | 611 | 186 | 3.13 / 89.10 | 6 | 25 |
6 | 13 | 101.08 | 20 | 15.25 | 449 | 137 | 3.27 / 89.24 | 6 | 22 |
7 | 8 | 0.08 | 272 | 15.22 | 292 | 1209 | 4.48 / 90.45 | 6 | 148 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 15 | 15.23 | 426 | 97 | 0.10 / 81.58 | 6 | 6 |
2 | 7 | 2008.36 | 41 | 14.85 | 2921 | 1778 | 1.88 / 83.35 | 8 | 17 |
3 | 13 | 1374.28 | 20 | 14.96 | 2120 | 634 | 2.51 / 83.99 | 5 | 25 |
4 | 13 | 808.56 | 20 | 15.06 | 1408 | 424 | 2.93 / 84.41 | 5 | 31 |
5 | 13 | 224.28 | 20 | 15.23 | 627 | 191 | 3.13 / 84.60 | 6 | 24 |
6 | 13 | 109.72 | 20 | 15.25 | 462 | 141 | 3.27 / 84.74 | 6 | 21 |
7 | 8 | 0.08 | 272 | 15.22 | 295 | 1221 | 4.49 / 85.97 | 6 | 141 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 15 | 15.21 | 458 | 104 | 0.10 / 77.09 | 6 | 6 |
2 | 7 | 2009.16 | 40 | 14.87 | 2912 | 1732 | 1.84 / 78.82 | 6 | 17 |
3 | 13 | 1458.68 | 20 | 14.96 | 2218 | 664 | 2.50 / 79.48 | 5 | 24 |
4 | 13 | 843.92 | 20 | 15.06 | 1450 | 437 | 2.94 / 79.92 | 5 | 31 |
5 | 13 | 254.56 | 20 | 15.22 | 667 | 203 | 3.14 / 80.12 | 6 | 28 |
6 | 13 | 94.80 | 20 | 15.26 | 440 | 134 | 3.27 / 80.26 | 6 | 24 |
7 | 8 | 0.12 | 272 | 15.23 | 295 | 1222 | 4.50 / 81.48 | 6 | 138 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 15 | 15.22 | 449 | 103 | 0.10 / 72.58 | 6 | 6 |
2 | 7 | 2010.40 | 41 | 14.84 | 2976 | 1811 | 1.91 / 74.40 | 6 | 18 |
3 | 13 | 1453.40 | 20 | 14.95 | 2221 | 664 | 2.58 / 75.06 | 5 | 24 |
4 | 13 | 727.20 | 20 | 15.08 | 1302 | 393 | 2.97 / 75.45 | 5 | 32 |
5 | 13 | 115.44 | 20 | 15.24 | 494 | 151 | 3.12 / 75.60 | 5 | 33 |
6 | 13 | 43.68 | 20 | 15.25 | 387 | 118 | 3.24 / 75.72 | 6 | 32 |
7 | 8 | -0.20 | 265 | 15.21 | 313 | 1262 | 4.50 / 76.98 | 6 | 131 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 15 | 15.23 | 431 | 98 | 0.10 / 68.15 | 6 | 6 |
2 | 7 | 2007.52 | 40 | 14.85 | 2940 | 1746 | 1.84 / 69.90 | 6 | 18 |
3 | 13 | 1473.20 | 20 | 14.95 | 2263 | 677 | 2.52 / 70.57 | 5 | 25 |
4 | 13 | 769.52 | 20 | 15.08 | 1357 | 409 | 2.93 / 70.98 | 5 | 33 |
5 | 13 | 155.56 | 20 | 15.25 | 539 | 164 | 3.10 / 71.15 | 6 | 26 |
6 | 13 | 54.84 | 20 | 15.27 | 392 | 120 | 3.21 / 71.27 | 6 | 23 |
7 | 8 | 0.00 | 267 | 15.23 | 299 | 1216 | 4.43 / 72.48 | 6 | 136 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 15 | 15.22 | 451 | 103 | 0.10 / 63.73 | 6 | 6 |
2 | 7 | 2008.64 | 40 | 14.86 | 2940 | 1748 | 1.85 / 65.48 | 6 | 18 |
3 | 13 | 1424.84 | 20 | 14.96 | 2188 | 655 | 2.51 / 66.13 | 5 | 25 |
4 | 13 | 781.24 | 20 | 15.08 | 1369 | 413 | 2.92 / 66.54 | 5 | 31 |
5 | 13 | 194.72 | 20 | 15.24 | 583 | 178 | 3.10 / 66.72 | 6 | 25 |
6 | 13 | 83.20 | 20 | 15.27 | 422 | 129 | 3.22 / 66.85 | 6 | 22 |
7 | 8 | 0.08 | 267 | 15.24 | 295 | 1200 | 4.42 / 68.05 | 6 | 132 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 15 | 15.23 | 436 | 100 | 0.10 / 59.28 | 6 | 6 |
2 | 7 | 2010.16 | 40 | 14.85 | 2983 | 1772 | 1.87 / 61.05 | 6 | 19 |
3 | 13 | 1331.04 | 20 | 14.98 | 2063 | 618 | 2.49 / 61.67 | 5 | 25 |
4 | 13 | 761.40 | 20 | 15.08 | 1354 | 408 | 2.90 / 62.08 | 5 | 33 |
5 | 13 | 135.36 | 20 | 15.26 | 514 | 157 | 3.05 / 62.24 | 6 | 29 |
6 | 13 | 58.24 | 20 | 15.27 | 401 | 122 | 3.18 / 62.36 | 6 | 28 |
7 | 8 | 0.04 | 270 | 15.23 | 308 | 1267 | 4.44 / 63.63 | 6 | 148 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 15 | 15.23 | 433 | 99 | 0.10 / 54.85 | 6 | 6 |
2 | 7 | 2007.00 | 40 | 14.86 | 2960 | 1759 | 1.86 / 56.61 | 6 | 18 |
3 | 13 | 1399.92 | 20 | 14.97 | 2161 | 647 | 2.51 / 57.26 | 5 | 26 |
4 | 13 | 724.28 | 20 | 15.10 | 1296 | 391 | 2.90 / 57.65 | 5 | 31 |
5 | 13 | 181.28 | 20 | 15.25 | 571 | 174 | 3.07 / 57.82 | 6 | 27 |
6 | 13 | 71.72 | 20 | 15.27 | 415 | 127 | 3.20 / 57.95 | 6 | 24 |
7 | 8 | 0.08 | 270 | 15.23 | 300 | 1234 | 4.43 / 59.18 | 6 | 145 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 15 | 15.24 | 430 | 98 | 0.10 / 50.37 | 6 | 6 |
2 | 7 | 2011.72 | 40 | 14.88 | 2936 | 1748 | 1.85 / 52.11 | 6 | 16 |
3 | 13 | 1374.80 | 20 | 14.98 | 2115 | 634 | 2.48 / 52.75 | 5 | 23 |
4 | 13 | 846.88 | 20 | 15.07 | 1450 | 437 | 2.92 / 53.18 | 5 | 31 |
5 | 13 | 208.40 | 20 | 15.25 | 610 | 186 | 3.10 / 53.37 | 6 | 27 |
6 | 13 | 88.72 | 20 | 15.27 | 442 | 135 | 3.24 / 53.50 | 6 | 24 |
7 | 8 | 0.04 | 270 | 15.24 | 303 | 1247 | 4.48 / 54.75 | 6 | 132 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 15 | 15.23 | 435 | 99 | 0.10 / 45.94 | 6 | 6 |
2 | 7 | 2004.28 | 40 | 14.88 | 2929 | 1743 | 1.84 / 47.69 | 6 | 18 |
3 | 13 | 1360.12 | 20 | 14.99 | 2091 | 627 | 2.47 / 48.31 | 5 | 24 |
4 | 13 | 785.24 | 20 | 15.09 | 1387 | 419 | 2.89 / 48.73 | 5 | 33 |
5 | 13 | 193.00 | 20 | 15.26 | 587 | 179 | 3.07 / 48.91 | 6 | 26 |
6 | 13 | 80.88 | 20 | 15.28 | 426 | 130 | 3.20 / 49.04 | 6 | 23 |
7 | 8 | 0.04 | 267 | 15.24 | 301 | 1225 | 4.42 / 50.27 | 6 | 144 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 15 | 15.24 | 428 | 98 | 0.10 / 41.53 | 6 | 6 |
2 | 7 | 2010.72 | 40 | 14.89 | 2904 | 1730 | 1.83 / 43.26 | 6 | 17 |
3 | 13 | 1410.80 | 20 | 14.98 | 2151 | 644 | 2.47 / 43.91 | 5 | 25 |
4 | 13 | 769.64 | 20 | 15.10 | 1355 | 409 | 2.88 / 44.32 | 5 | 31 |
5 | 13 | 191.16 | 20 | 15.26 | 581 | 177 | 3.06 / 44.50 | 6 | 26 |
6 | 13 | 81.32 | 20 | 15.28 | 423 | 129 | 3.19 / 44.62 | 6 | 23 |
7 | 8 | 0.04 | 267 | 15.24 | 300 | 1221 | 4.41 / 45.85 | 6 | 132 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 15 | 15.25 | 428 | 98 | 0.10 / 37.12 | 6 | 6 |
2 | 7 | 2004.04 | 40 | 14.88 | 2923 | 1740 | 1.84 / 38.86 | 6 | 18 |
3 | 13 | 1342.88 | 20 | 15.00 | 2065 | 619 | 2.46 / 39.48 | 5 | 24 |
4 | 13 | 787.64 | 20 | 15.10 | 1374 | 415 | 2.87 / 39.89 | 5 | 32 |
5 | 13 | 194.04 | 20 | 15.26 | 580 | 177 | 3.05 / 40.07 | 6 | 26 |
6 | 13 | 82.96 | 20 | 15.28 | 423 | 129 | 3.18 / 40.20 | 6 | 23 |
7 | 8 | 0.08 | 272 | 15.25 | 298 | 1236 | 4.41 / 41.44 | 6 | 137 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 15 | 15.25 | 427 | 98 | 0.10 / 32.72 | 6 | 6 |
2 | 7 | 2003.72 | 40 | 14.88 | 2935 | 1747 | 1.84 / 34.47 | 6 | 17 |
3 | 13 | 1347.32 | 20 | 15.00 | 2085 | 625 | 2.47 / 35.10 | 5 | 25 |
4 | 13 | 739.72 | 20 | 15.12 | 1320 | 399 | 2.87 / 35.50 | 5 | 31 |
5 | 13 | 193.28 | 20 | 15.27 | 582 | 178 | 3.05 / 35.67 | 6 | 25 |
6 | 13 | 84.52 | 20 | 15.29 | 424 | 130 | 3.18 / 35.80 | 6 | 22 |
7 | 8 | 0.08 | 270 | 15.25 | 296 | 1219 | 4.40 / 37.02 | 6 | 146 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 15 | 15.24 | 431 | 99 | 0.10 / 28.35 | 6 | 6 |
2 | 7 | 2002.72 | 40 | 14.90 | 2909 | 1734 | 1.83 / 30.08 | 6 | 17 |
3 | 13 | 1363.56 | 20 | 15.00 | 2119 | 636 | 2.47 / 30.72 | 5 | 24 |
4 | 13 | 727.76 | 20 | 15.12 | 1303 | 394 | 2.86 / 31.11 | 5 | 30 |
5 | 13 | 188.36 | 20 | 15.27 | 576 | 176 | 3.04 / 31.29 | 6 | 25 |
6 | 13 | 76.96 | 20 | 15.29 | 410 | 125 | 3.16 / 31.42 | 6 | 21 |
7 | 8 | 0.04 | 270 | 15.26 | 294 | 1211 | 4.37 / 32.63 | 6 | 152 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 15 | 15.24 | 450 | 103 | 0.10 / 23.87 | 6 | 6 |
2 | 7 | 2011.08 | 40 | 14.91 | 2906 | 1733 | 1.84 / 25.60 | 6 | 17 |
3 | 13 | 1455.20 | 20 | 14.99 | 2204 | 661 | 2.50 / 26.26 | 5 | 22 |
4 | 13 | 846.60 | 20 | 15.09 | 1441 | 435 | 2.93 / 26.70 | 5 | 29 |
5 | 13 | 175.76 | 20 | 15.27 | 558 | 170 | 3.10 / 26.87 | 5 | 28 |
6 | 13 | 64.80 | 20 | 15.29 | 403 | 123 | 3.23 / 26.99 | 6 | 25 |
7 | 8 | 0.04 | 274 | 15.25 | 302 | 1262 | 4.49 / 28.25 | 6 | 135 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 15 | 15.25 | 455 | 104 | 0.10 / 19.46 | 6 | 6 |
2 | 7 | 2004.64 | 40 | 14.91 | 2916 | 1739 | 1.84 / 21.20 | 6 | 16 |
3 | 13 | 1338.52 | 20 | 15.01 | 2082 | 625 | 2.47 / 21.82 | 5 | 24 |
4 | 13 | 771.92 | 20 | 15.11 | 1354 | 409 | 2.88 / 22.23 | 5 | 31 |
5 | 13 | 148.36 | 20 | 15.27 | 526 | 161 | 3.04 / 22.39 | 6 | 28 |
6 | 13 | 41.80 | 20 | 15.30 | 371 | 114 | 3.15 / 22.50 | 6 | 26 |
7 | 8 | 0.00 | 270 | 15.25 | 306 | 1260 | 4.41 / 23.76 | 6 | 133 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 15 | 15.25 | 445 | 102 | 0.10 / 15.06 | 6 | 6 |
2 | 7 | 2012.36 | 40 | 14.91 | 2928 | 1746 | 1.85 / 16.81 | 6 | 16 |
3 | 13 | 1341.96 | 20 | 15.02 | 2066 | 621 | 2.47 / 17.43 | 5 | 23 |
4 | 13 | 743.28 | 20 | 15.12 | 1320 | 399 | 2.87 / 17.83 | 5 | 30 |
5 | 13 | 127.88 | 20 | 15.28 | 495 | 151 | 3.02 / 17.98 | 6 | 26 |
6 | 13 | 29.52 | 20 | 15.30 | 351 | 107 | 3.13 / 18.09 | 6 | 24 |
7 | 8 | 0.04 | 272 | 15.25 | 305 | 1265 | 4.39 / 19.35 | 6 | 134 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 15 | 15.25 | 447 | 102 | 0.10 / 10.69 | 6 | 6 |
2 | 7 | 2002.96 | 40 | 14.91 | 2942 | 1755 | 1.86 / 12.45 | 6 | 16 |
3 | 13 | 1307.08 | 20 | 15.03 | 2029 | 610 | 2.47 / 13.06 | 5 | 25 |
4 | 13 | 778.84 | 20 | 15.12 | 1371 | 415 | 2.88 / 13.47 | 5 | 29 |
5 | 13 | 142.68 | 20 | 15.29 | 513 | 157 | 3.04 / 13.63 | 6 | 24 |
6 | 13 | 39.68 | 20 | 15.31 | 364 | 111 | 3.15 / 13.74 | 6 | 23 |
7 | 8 | 0.00 | 267 | 15.26 | 300 | 1222 | 4.37 / 14.96 | 6 | 140 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 14 | 15.24 | 421 | 90 | 0.09 / 6.27 | 6 | 6 |
2 | 7 | 2009.04 | 41 | 14.92 | 2893 | 1770 | 1.86 / 8.04 | 11 | 15 |
3 | 13 | 1332.72 | 20 | 15.02 | 2047 | 615 | 2.47 / 8.66 | 5 | 22 |
4 | 13 | 769.36 | 20 | 15.11 | 1352 | 409 | 2.88 / 9.07 | 5 | 28 |
5 | 13 | 211.04 | 20 | 15.27 | 605 | 185 | 3.07 / 9.25 | 6 | 24 |
6 | 13 | 58.16 | 20 | 15.30 | 382 | 117 | 3.18 / 9.37 | 6 | 20 |
7 | 8 | 0.20 | 272 | 15.26 | 294 | 1220 | 4.40 / 10.59 | 6 | 138 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 18 | 15.42 | 405 | 112 | 0.11 / 1.89 | 6 | 6 |
2 | 3 | 1314.68 | -3 | 15.60 | 8 | 0 | 0.00 / 1.89 | 6 | 6 |
3 | 7 | 2009.48 | 40 | 14.93 | 2859 | 1707 | 1.82 / 3.60 | 6 | 14 |
4 | 13 | 1404.84 | 20 | 15.01 | 2140 | 642 | 2.46 / 4.24 | 5 | 21 |
5 | 13 | 803.80 | 20 | 15.11 | 1391 | 420 | 2.88 / 4.66 | 5 | 27 |
6 | 13 | 218.24 | 20 | 15.26 | 612 | 187 | 3.07 / 4.85 | 6 | 23 |
7 | 13 | 68.24 | 20 | 15.29 | 397 | 121 | 3.19 / 4.97 | 6 | 19 |
8 | 8 | 0.04 | 274 | 15.25 | 291 | 1216 | 4.41 / 6.18 | 6 | 132 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 137.32 | 18 | 15.57 | 467 | 131 | 0.13 / 0.13 | 6 | 6 |
2 | 7 | 151.12 | 40 | 15.55 | 470 | 292 | 0.42 / 0.42 | 6 | 6 |
3 | 13 | 158.80 | 20 | 15.53 | 478 | 148 | 0.57 / 0.57 | 6 | 6 |
4 | 13 | 96.12 | 20 | 15.53 | 386 | 120 | 0.69 / 0.69 | 6 | 7 |
5 | 8 | 0.20 | 272 | 15.48 | 258 | 1086 | 1.78 / 1.78 | 6 | 137 |
Average= | 1.78 (KJ/cycle) |