SIO Argo Site:
Pump Diagnostics Page   



Serial= 7772 WMO= 4903543

Return

←PreviousNext→

Cycle 112 GMT 20/12/2024 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 14 15.05 455 96 0.10 / 490.59 5 7
2 7 2004.72 40 14.62 3241 1895 1.99 / 492.48 7 27
3 13 1308.24 20 14.73 2241 660 2.65 / 493.14 5 35
4 13 681.68 20 14.88 1320 393 3.04 / 493.53 5 35
5 13 79.80 20 15.07 442 133 3.18 / 493.67 5 33
6 8 0.04 267 15.03 313 1256 4.43 / 494.92 5 136
Average= 4.38
(KJ/cycle)

Cycle 111 GMT 15/12/2024 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 14 15.04 471 99 0.10 / 486.22 5 8
2 7 2006.88 40 14.61 3232 1889 1.99 / 488.11 8 24
3 13 1272.04 20 14.74 2174 641 2.63 / 488.75 5 35
4 13 585.92 20 14.91 1183 353 2.98 / 489.10 5 37
5 13 104.80 20 15.05 482 145 3.13 / 489.25 5 40
6 13 16.12 20 15.08 344 104 3.23 / 489.35 5 31
7 8 0.00 244 15.03 311 1141 4.37 / 490.49 5 132
Average= 4.38
(KJ/cycle)

Cycle 110 GMT 10/12/2024 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 14 15.05 454 96 0.10 / 481.79 5 7
2 7 2003.04 40 14.62 3192 1867 1.96 / 483.65 7 25
3 13 1319.28 20 14.72 2261 666 2.63 / 484.32 5 36
4 13 667.68 20 14.88 1301 387 3.02 / 484.71 5 40
5 13 106.32 20 15.06 485 146 3.16 / 484.85 5 38
6 13 16.60 20 15.08 346 104 3.27 / 484.96 5 31
7 8 -0.04 248 15.03 312 1163 4.43 / 486.12 5 139
Average= 4.38
(KJ/cycle)

Cycle 109 GMT 5/12/2024 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 14 15.06 457 96 0.10 / 477.43 5 7
2 7 2004.08 40 14.63 3157 1847 1.94 / 479.28 7 26
3 13 1304.92 20 14.73 2219 654 2.60 / 479.93 5 35
4 13 608.32 20 14.90 1231 367 2.96 / 480.30 5 38
5 13 87.28 20 15.06 457 138 3.10 / 480.44 5 33
6 8 0.04 265 15.03 315 1255 4.36 / 481.69 5 131
Average= 4.38
(KJ/cycle)

Cycle 108 GMT 30/11/2024 8:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 14 15.05 468 99 0.10 / 473.04 5 7
2 7 2009.92 40 14.61 3245 1896 1.99 / 474.93 7 25
3 13 1272.72 20 14.74 2170 640 2.63 / 475.57 5 34
4 13 627.08 20 14.90 1251 373 3.01 / 475.94 5 37
5 13 78.88 20 15.07 442 133 3.14 / 476.08 5 30
6 8 0.08 267 15.04 313 1257 4.40 / 477.33 5 138
Average= 4.38
(KJ/cycle)

Cycle 107 GMT 25/11/2024 7:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 14 15.06 459 97 0.10 / 468.61 5 7
2 7 2007.36 40 14.63 3191 1867 1.96 / 470.47 7 25
3 13 1310.84 20 14.73 2248 662 2.63 / 471.14 5 34
4 13 655.28 20 14.89 1283 382 3.01 / 471.52 5 38
5 13 95.16 20 15.07 467 141 3.15 / 471.66 5 31
6 13 33.56 20 15.08 375 113 3.26 / 471.77 5 33
7 8 0.20 248 15.04 312 1164 4.43 / 472.94 5 144
Average= 4.38
(KJ/cycle)

Cycle 106 GMT 20/11/2024 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 14 15.06 461 97 0.10 / 464.25 5 6
2 7 2004.76 40 14.63 3201 1873 1.97 / 466.12 6 27
3 13 1266.24 20 14.75 2184 644 2.61 / 466.76 5 33
4 13 557.52 20 14.93 1143 341 2.96 / 467.11 5 39
5 13 89.36 20 15.07 458 138 3.09 / 467.24 5 31
6 13 28.20 20 15.08 362 109 3.20 / 467.35 5 34
7 8 0.00 246 15.04 313 1158 4.36 / 468.51 5 136
Average= 4.38
(KJ/cycle)

Cycle 105 GMT 15/11/2024 5:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 14 15.05 453 95 0.10 / 459.89 5 8
2 7 2003.84 40 14.64 3151 1845 1.94 / 461.74 8 24
3 13 1315.56 20 14.74 2240 660 2.60 / 462.40 5 34
4 13 599.60 20 14.91 1202 358 2.96 / 462.76 5 41
5 13 60.64 20 15.08 413 125 3.08 / 462.88 5 35
6 13 15.36 20 15.09 348 105 3.19 / 462.99 5 34
7 8 0.04 246 15.03 314 1161 4.35 / 464.15 5 138
Average= 4.38
(KJ/cycle)

Cycle 104 GMT 10/11/2024 4:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 14 15.06 448 94 0.09 / 455.51 5 9
2 7 2005.52 40 14.62 3189 1865 1.96 / 457.37 9 27
3 13 1267.20 20 14.75 2171 640 2.60 / 458.01 5 32
4 13 661.60 20 14.89 1285 383 2.98 / 458.39 5 28
5 13 52.44 20 15.08 414 125 3.11 / 458.52 5 38
6 13 13.88 20 15.08 348 105 3.21 / 458.62 5 31
7 8 0.00 246 15.03 318 1176 4.39 / 459.80 5 142
Average= 4.38
(KJ/cycle)

Cycle 103 GMT 5/11/2024 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 14 15.05 448 94 0.09 / 451.14 5 7
2 7 2008.96 40 14.64 3173 1858 1.95 / 453.00 7 25
3 13 1301.44 20 14.74 2225 656 2.61 / 453.65 5 33
4 13 647.16 20 14.90 1266 377 2.99 / 454.03 5 39
5 13 44.24 20 15.08 392 118 3.10 / 454.15 5 35
6 8 0.56 267 15.04 314 1261 4.36 / 455.41 5 143
Average= 4.38
(KJ/cycle)

Cycle 102 GMT 31/10/2024 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 14 15.05 453 95 0.10 / 446.70 5 6
2 7 2006.80 40 14.63 3190 1867 1.96 / 448.57 6 26
3 13 1348.64 20 14.74 2280 672 2.63 / 449.24 5 33
4 13 693.44 20 14.88 1310 390 3.02 / 449.63 5 37
5 13 63.96 20 15.08 420 127 3.15 / 449.76 5 35
6 13 15.64 20 15.09 346 104 3.26 / 449.86 5 34
7 8 0.04 251 15.03 314 1185 4.44 / 451.05 5 146
Average= 4.38
(KJ/cycle)

Cycle 101 GMT 26/10/2024 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 14 15.06 456 96 0.10 / 442.31 5 6
2 7 2002.56 40 14.62 3214 1880 1.98 / 444.19 6 25
3 13 1308.00 20 14.74 2232 658 2.63 / 444.85 5 34
4 13 616.80 20 14.91 1231 367 3.00 / 445.21 5 38
5 13 55.44 20 15.08 412 124 3.13 / 445.34 5 37
6 8 0.08 267 15.04 316 1269 4.39 / 446.61 5 141
Average= 4.38
(KJ/cycle)

Cycle 100 GMT 21/10/2024 1: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 14 15.06 457 96 0.10 / 437.90 5 7
2 7 2007.64 40 14.63 3217 1883 1.98 / 439.78 7 27
3 13 1344.72 20 14.73 2290 675 2.65 / 440.46 5 33
4 13 646.76 20 14.90 1267 378 3.03 / 440.84 5 40
5 13 47.16 20 15.09 395 119 3.15 / 440.96 5 33
6 8 0.24 267 15.04 313 1257 4.41 / 442.21 5 147
Average= 4.38
(KJ/cycle)

Cycle 99 GMT 16/10/2024 0: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 14 15.05 462 97 0.10 / 433.53 5 8
2 7 2010.20 40 14.64 3176 1860 1.96 / 435.39 8 25
3 13 1284.60 20 14.75 2200 649 2.61 / 436.04 5 34
4 13 662.24 20 14.90 1284 383 2.99 / 436.42 5 39
5 13 59.52 20 15.08 413 125 3.11 / 436.55 5 35
6 8 0.04 267 15.04 313 1257 4.37 / 437.81 5 137
Average= 4.38
(KJ/cycle)

Cycle 98 GMT 10/10/2024 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 14 15.06 456 96 0.10 / 429.16 5 6
2 7 2009.04 40 14.64 3160 1850 1.95 / 431.01 6 25
3 13 1256.20 20 14.76 2158 637 2.58 / 431.65 5 34
4 13 680.12 20 14.89 1307 389 2.97 / 432.04 5 38
5 13 43.44 20 15.09 397 120 3.09 / 432.16 5 32
6 8 0.08 267 15.04 318 1277 4.37 / 433.44 5 135
Average= 4.38
(KJ/cycle)

Cycle 97 GMT 5/10/2024 22:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 14 15.06 448 94 0.09 / 424.79 5 7
2 7 2004.28 40 14.64 3181 1863 1.96 / 426.65 7 26
3 13 1263.72 20 14.76 2182 644 2.60 / 427.30 5 35
4 13 647.48 20 14.90 1273 379 2.98 / 427.68 5 39
5 13 41.12 20 15.09 393 119 3.10 / 427.79 5 34
6 8 0.00 265 15.04 319 1271 4.37 / 429.07 5 137
Average= 4.38
(KJ/cycle)

Cycle 96 GMT 30/ 9/2024 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 14 15.06 454 96 0.10 / 420.40 5 7
2 7 2009.16 40 14.64 3203 1876 1.97 / 422.28 7 24
3 13 1280.64 20 14.75 2201 649 2.62 / 422.93 5 34
4 13 622.88 20 14.91 1235 368 2.99 / 423.30 5 40
5 13 58.16 20 15.08 414 125 3.11 / 423.42 5 33
6 13 16.80 20 15.09 347 105 3.22 / 423.53 5 35
7 8 0.04 244 15.04 318 1167 4.39 / 424.69 5 129
Average= 4.38
(KJ/cycle)

Cycle 95 GMT 25/ 9/2024 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 14 15.06 458 97 0.10 / 415.98 5 6
2 7 2007.52 41 14.62 3226 1934 2.03 / 417.92 6 27
3 13 1270.76 20 14.75 2203 650 2.68 / 418.57 5 35
4 13 553.56 20 14.93 1149 343 3.02 / 418.91 5 42
5 13 46.28 20 15.09 400 121 3.14 / 419.03 5 36
6 13 13.28 20 15.09 345 104 3.25 / 419.14 5 34
7 8 -0.04 246 15.04 317 1173 4.42 / 420.31 5 143
Average= 4.38
(KJ/cycle)

Cycle 94 GMT 20/ 9/2024 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 14 15.07 449 95 0.09 / 411.58 5 7
2 7 2007.32 40 14.64 3182 1863 1.96 / 413.44 7 25
3 13 1288.36 20 14.76 2193 647 2.61 / 414.09 5 34
4 13 638.16 20 14.91 1256 375 2.98 / 414.47 5 40
5 13 53.60 20 15.09 409 123 3.10 / 414.59 5 35
6 13 29.72 20 15.09 375 113 3.22 / 414.70 5 35
7 8 0.00 248 15.04 318 1186 4.40 / 415.89 5 136
Average= 4.38
(KJ/cycle)

Cycle 93 GMT 15/ 9/2024 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 14 15.06 452 95 0.10 / 407.18 5 6
2 7 2004.84 40 14.64 3213 1882 1.98 / 409.06 6 25
3 13 1311.76 20 14.75 2245 662 2.64 / 409.72 5 34
4 13 593.44 20 14.92 1202 359 3.00 / 410.08 5 40
5 13 48.44 20 15.09 400 121 3.12 / 410.20 5 34
6 13 29.08 20 15.09 372 112 3.23 / 410.32 5 34
7 8 0.00 246 15.04 316 1169 4.40 / 411.49 5 135
Average= 4.38
(KJ/cycle)

Cycle 92 GMT 10/ 9/2024 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 14 15.06 454 96 0.10 / 402.81 5 6
2 7 2005.80 40 14.64 3163 1852 1.95 / 404.67 6 28
3 13 1282.40 20 14.76 2194 648 2.60 / 405.31 5 32
4 13 629.76 20 14.91 1244 371 2.97 / 405.68 5 40
5 13 43.40 20 15.09 394 119 3.09 / 405.80 5 34
6 8 -0.04 267 15.05 319 1282 4.37 / 407.09 5 139
Average= 4.38
(KJ/cycle)

Cycle 91 GMT 5/ 9/2024 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 14 15.07 444 94 0.09 / 398.40 5 6
2 7 2003.20 41 14.64 3189 1914 2.01 / 400.31 6 24
3 13 1228.56 20 14.77 2133 630 2.64 / 400.94 5 35
4 13 609.40 20 14.92 1232 368 3.01 / 401.31 5 39
5 13 77.24 20 15.08 447 135 3.14 / 401.45 5 34
6 13 22.64 20 15.09 361 109 3.25 / 401.56 5 36
7 8 0.04 246 15.05 314 1163 4.41 / 402.72 5 142
Average= 4.38
(KJ/cycle)

Cycle 90 GMT 31/ 8/2024 16:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 14 15.06 456 96 0.10 / 394.05 5 7
2 7 2002.44 40 14.64 3184 1865 1.96 / 395.91 7 27
3 13 1296.12 20 14.76 2222 656 2.62 / 396.57 5 34
4 13 529.04 20 14.94 1104 330 2.95 / 396.90 5 39
5 13 82.52 20 15.08 457 138 3.08 / 397.03 5 36
6 13 24.80 20 15.09 365 110 3.19 / 397.14 5 36
7 8 -0.04 246 15.05 314 1163 4.36 / 398.31 5 139
Average= 4.38
(KJ/cycle)

Cycle 89 GMT 26/ 8/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 14 15.06 467 98 0.10 / 389.65 5 6
2 7 2005.68 40 14.64 3222 1887 1.99 / 391.54 6 25
3 13 1300.88 20 14.76 2209 652 2.64 / 392.19 5 33
4 13 605.40 20 14.92 1216 363 3.00 / 392.56 5 42
5 13 59.64 20 15.09 419 126 3.13 / 392.68 5 33
6 13 19.48 20 15.09 358 108 3.23 / 392.79 5 33
7 8 0.04 246 15.05 313 1159 4.39 / 393.95 5 130
Average= 4.38
(KJ/cycle)

Cycle 88 GMT 21/ 8/2024 14:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 14 15.07 453 96 0.10 / 385.27 5 6
2 7 2006.92 40 14.64 3183 1864 1.96 / 387.14 6 27
3 13 1235.64 20 14.76 2156 636 2.60 / 387.77 5 36
4 13 604.20 20 14.92 1215 363 2.96 / 388.14 5 39
5 13 84.56 20 15.08 451 136 3.09 / 388.27 5 34
6 13 22.80 20 15.09 361 109 3.20 / 388.38 5 34
7 8 0.04 246 15.05 317 1174 4.38 / 389.56 5 130
Average= 4.38
(KJ/cycle)

Cycle 87 GMT 16/ 8/2024 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 14 15.06 470 99 0.10 / 380.86 5 6
2 7 2009.52 40 14.64 3210 1880 1.98 / 382.74 6 25
3 13 1273.56 20 14.76 2189 646 2.63 / 383.39 5 34
4 13 597.76 20 14.92 1219 364 2.99 / 383.75 5 41
5 13 121.64 20 15.08 504 152 3.14 / 383.90 5 32
6 13 19.48 20 15.10 349 105 3.25 / 384.01 5 32
7 8 0.04 248 15.05 313 1168 4.41 / 385.18 5 145
Average= 4.38
(KJ/cycle)

Cycle 86 GMT 11/ 8/2024 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 14 15.07 462 97 0.10 / 376.48 5 7
2 7 2006.04 40 14.64 3195 1871 1.97 / 378.35 7 26
3 13 1235.24 20 14.77 2154 636 2.60 / 378.99 5 36
4 13 595.56 20 14.93 1205 360 2.96 / 379.35 5 40
5 13 111.80 20 15.08 495 149 3.11 / 379.50 5 34
6 13 15.76 20 15.10 343 104 3.22 / 379.60 5 31
7 8 0.00 248 15.05 312 1165 4.38 / 380.76 5 144
Average= 4.38
(KJ/cycle)

Cycle 85 GMT 6/ 8/2024 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 14 15.07 468 99 0.10 / 372.10 5 6
2 7 2005.68 40 14.65 3207 1879 1.98 / 373.98 6 27
3 13 1247.92 20 14.78 2141 633 2.61 / 374.61 5 32
4 13 579.24 20 14.94 1162 347 2.96 / 374.96 5 35
5 13 107.48 20 15.08 482 145 3.10 / 375.10 5 33
6 13 32.32 20 15.10 370 112 3.22 / 375.21 5 31
7 8 0.04 248 15.05 313 1168 4.38 / 376.38 5 143
Average= 4.38
(KJ/cycle)

Cycle 84 GMT 1/ 8/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 14 15.08 449 95 0.09 / 367.63 5 6
2 7 2008.72 41 14.64 3205 1924 2.02 / 369.55 6 26
3 13 1343.48 20 14.75 2277 672 2.69 / 370.22 5 35
4 13 637.72 20 14.92 1255 374 3.06 / 370.60 5 39
5 13 71.16 20 15.09 431 130 3.19 / 370.73 5 31
6 13 19.00 20 15.11 347 105 3.30 / 370.83 5 30
7 8 0.00 246 15.05 315 1166 4.47 / 372.00 5 141
Average= 4.38
(KJ/cycle)

Cycle 83 GMT 27/ 7/2024 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 14 15.07 461 97 0.10 / 363.22 5 7
2 7 2006.56 40 14.65 3193 1871 1.97 / 365.09 7 26
3 13 1284.84 20 14.77 2184 645 2.61 / 365.74 5 31
4 13 643.88 20 14.92 1266 378 2.99 / 366.12 5 40
5 13 88.20 20 15.09 455 137 3.13 / 366.25 5 34
6 13 24.60 20 15.10 362 109 3.24 / 366.36 5 32
7 8 0.00 248 15.06 313 1169 4.41 / 367.53 5 142
Average= 4.38
(KJ/cycle)

Cycle 82 GMT 22/ 7/2024 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 14 15.07 455 96 0.10 / 358.81 5 6
2 7 2010.24 40 14.64 3236 1895 1.99 / 360.71 6 26
3 13 1279.76 20 14.76 2211 653 2.64 / 361.36 5 35
4 13 622.28 20 14.92 1254 374 3.02 / 361.74 5 40
5 13 93.56 20 15.09 467 141 3.16 / 361.88 5 33
6 8 0.04 265 15.06 313 1249 4.41 / 363.13 5 136
Average= 4.38
(KJ/cycle)

Cycle 81 GMT 17/ 7/2024 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 14 15.08 457 96 0.10 / 354.41 5 7
2 7 2007.84 40 14.65 3203 1877 1.97 / 356.28 7 25
3 13 1289.16 20 14.77 2226 658 2.63 / 356.94 5 33
4 13 603.88 20 14.94 1207 361 2.99 / 357.30 5 37
5 13 127.36 20 15.08 511 154 3.15 / 357.46 5 35
6 13 18.40 20 15.11 344 104 3.25 / 357.56 5 31
7 8 -0.08 248 15.06 310 1158 4.41 / 358.72 5 148
Average= 4.37
(KJ/cycle)

Cycle 80 GMT 12/ 7/2024 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 14 15.08 459 97 0.10 / 350.04 5 7
2 7 2009.88 40 14.65 3226 1890 1.99 / 351.93 7 27
3 13 1238.28 20 14.78 2137 632 2.62 / 352.56 5 33
4 13 595.76 20 14.95 1194 357 2.98 / 352.92 5 36
5 13 118.48 20 15.09 496 150 3.13 / 353.07 5 32
6 8 0.12 267 15.07 309 1243 4.37 / 354.31 5 148
Average= 4.37
(KJ/cycle)

Cycle 79 GMT 7/ 7/2024 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 14 15.08 447 94 0.09 / 345.62 5 6
2 7 2010.32 40 14.65 3256 1908 2.00 / 347.52 6 27
3 13 1269.00 20 14.78 2181 645 2.65 / 348.17 5 33
4 13 650.44 20 14.93 1269 379 3.03 / 348.55 5 35
5 13 119.20 20 15.09 502 152 3.18 / 348.70 5 32
6 8 -0.12 265 15.07 311 1242 4.42 / 349.94 5 138
Average= 4.37
(KJ/cycle)

Cycle 78 GMT 2/ 7/2024 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 14 15.08 457 96 0.10 / 341.17 5 6
2 7 2003.24 40 14.67 3180 1866 1.96 / 343.03 6 26
3 13 1322.24 20 14.77 2259 667 2.63 / 343.70 5 35
4 13 676.84 20 14.92 1314 392 3.02 / 344.09 5 36
5 13 124.32 20 15.09 508 153 3.18 / 344.24 5 31
6 13 19.08 20 15.12 347 105 3.28 / 344.35 5 28
7 8 0.04 248 15.06 314 1173 4.45 / 345.52 5 138
Average= 4.37
(KJ/cycle)

Cycle 77 GMT 27/ 6/2024 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 14 15.09 455 96 0.10 / 336.72 5 7
2 7 2010.56 40 14.66 3228 1893 1.99 / 338.61 7 27
3 13 1317.48 20 14.77 2273 671 2.66 / 339.28 5 34
4 13 658.96 20 14.93 1293 386 3.05 / 339.67 5 40
5 13 98.44 20 15.10 473 143 3.19 / 339.81 5 31
6 8 0.04 265 15.08 314 1255 4.44 / 341.07 5 130
Average= 4.37
(KJ/cycle)

Cycle 76 GMT 22/ 6/2024 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 14 15.08 477 101 0.10 / 332.30 5 6
2 7 2006.40 40 14.66 3212 1884 1.98 / 334.18 6 24
3 13 1285.24 20 14.78 2225 658 2.64 / 334.84 5 35
4 13 641.24 20 14.93 1267 378 3.02 / 335.22 5 38
5 13 123.56 20 15.10 506 153 3.17 / 335.37 5 31
6 13 16.40 20 15.12 343 104 3.28 / 335.47 5 30
7 8 0.04 246 15.07 311 1153 4.43 / 336.62 5 135
Average= 4.37
(KJ/cycle)

Cycle 75 GMT 17/ 6/2024 3: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 14 15.09 457 97 0.10 / 327.94 5 6
2 7 2004.00 40 14.67 3193 1874 1.97 / 329.82 6 27
3 13 1249.48 20 14.80 2139 633 2.60 / 330.45 5 34
4 13 568.96 20 14.97 1142 342 2.95 / 330.79 5 38
5 13 123.60 20 15.10 504 152 3.10 / 330.94 5 32
6 8 0.08 265 15.08 313 1251 4.35 / 332.19 5 133
Average= 4.37
(KJ/cycle)

Cycle 74 GMT 12/ 6/2024 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 14 15.09 451 95 0.10 / 323.56 5 6
2 7 2004.40 40 14.67 3201 1878 1.97 / 325.44 6 26
3 13 1264.84 20 14.79 2185 646 2.62 / 326.08 5 35
4 13 609.64 20 14.95 1226 367 2.99 / 326.45 5 39
5 13 96.24 20 15.11 470 142 3.13 / 326.59 5 30
6 8 0.08 267 15.08 312 1256 4.38 / 327.85 5 145
Average= 4.37
(KJ/cycle)

Cycle 73 GMT 7/ 6/2024 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 14 15.10 458 97 0.10 / 319.16 5 6
2 7 2004.08 40 14.67 3205 1881 1.98 / 321.05 6 24
3 13 1228.80 20 14.79 2147 635 2.61 / 321.68 5 35
4 13 624.40 20 14.95 1232 368 2.98 / 322.05 5 37
5 13 137.84 20 15.10 533 161 3.14 / 322.21 5 32
6 8 0.08 267 15.08 311 1252 4.39 / 323.46 5 140
Average= 4.37
(KJ/cycle)

Cycle 72 GMT 2/ 6/2024 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 14 15.10 459 97 0.10 / 314.80 5 7
2 7 2007.48 40 14.67 3229 1895 1.99 / 316.69 7 27
3 13 1181.80 20 14.81 2055 609 2.60 / 317.30 5 36
4 13 587.24 20 14.97 1186 355 2.96 / 317.65 5 35
5 13 148.96 20 15.10 544 164 3.12 / 317.82 5 31
6 8 0.12 267 15.09 310 1249 4.37 / 319.07 5 144
Average= 4.37
(KJ/cycle)

Cycle 71 GMT 27/ 5/2024 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 14 15.11 462 98 0.10 / 310.36 5 7
2 7 2004.88 41 14.67 3204 1927 2.02 / 312.29 7 25
3 13 1253.20 20 14.80 2151 637 2.66 / 312.93 5 34
4 13 603.72 20 14.97 1202 360 3.02 / 313.29 5 38
5 13 164.28 20 15.10 562 170 3.19 / 313.46 5 31
6 8 0.08 265 15.09 311 1244 4.43 / 314.70 5 131
Average= 4.37
(KJ/cycle)

Cycle 70 GMT 22/ 5/2024 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 14 15.10 465 98 0.10 / 305.94 5 6
2 7 2008.04 40 14.68 3197 1877 1.98 / 307.82 6 27
3 13 1320.20 20 14.79 2240 663 2.64 / 308.48 5 33
4 13 667.00 20 14.96 1272 381 3.02 / 308.86 5 36
5 13 144.76 20 15.11 531 160 3.18 / 309.02 5 28
6 8 0.12 267 15.10 308 1242 4.42 / 310.26 5 135
Average= 4.37
(KJ/cycle)

Cycle 69 GMT 17/ 5/2024 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 14 15.11 452 96 0.10 / 301.51 5 7
2 7 2008.72 40 14.69 3194 1877 1.97 / 303.38 7 24
3 13 1284.40 20 14.81 2182 646 2.62 / 304.03 5 33
4 13 686.92 20 14.95 1336 399 3.02 / 304.43 5 39
5 13 126.04 20 15.12 506 153 3.17 / 304.58 5 31
6 8 0.08 267 15.10 313 1262 4.43 / 305.84 5 132
Average= 4.37
(KJ/cycle)

Cycle 68 GMT 12/ 5/2024 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 14 15.10 461 97 0.10 / 297.15 5 7
2 7 2004.40 40 14.70 3164 1860 1.96 / 299.01 7 25
3 13 1280.48 20 14.81 2192 649 2.61 / 299.66 5 34
4 13 599.28 20 14.98 1211 363 2.97 / 300.02 5 39
5 13 54.72 20 15.14 408 124 3.09 / 300.14 5 32
6 8 0.04 265 15.10 317 1268 4.36 / 301.41 5 140
Average= 4.37
(KJ/cycle)

Cycle 67 GMT 7/ 5/2024 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 14 15.10 473 100 0.10 / 292.69 5 7
2 7 2008.28 40 14.69 3198 1879 1.98 / 294.57 7 25
3 13 1393.76 20 14.79 2344 693 2.67 / 295.27 5 31
4 13 644.52 20 14.97 1262 378 3.05 / 295.65 5 37
5 13 50.64 20 15.14 403 122 3.17 / 295.77 5 32
6 8 0.04 265 15.10 320 1280 4.45 / 297.05 5 133
Average= 4.37
(KJ/cycle)

Cycle 66 GMT 2/ 5/2024 19: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 14 15.11 454 96 0.10 / 288.50 5 7
2 7 1791.96 40 14.75 2933 1730 1.83 / 290.23 7 28
3 13 1269.24 20 14.83 2200 653 2.48 / 290.88 5 35
4 13 492.68 20 15.03 1053 317 2.80 / 291.20 5 39
5 13 49.84 20 15.15 401 122 2.92 / 291.32 5 33
6 8 0.04 261 15.10 323 1273 4.19 / 292.60 5 134
Average= 4.37
(KJ/cycle)

Cycle 65 GMT 27/ 4/2024 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 14 15.10 463 98 0.10 / 284.13 5 7
2 7 2008.80 40 14.69 3194 1877 1.97 / 286.00 7 28
3 13 1260.56 20 14.82 2180 646 2.62 / 286.65 5 35
4 13 568.36 20 14.99 1165 349 2.97 / 287.00 5 40
5 13 53.96 20 15.14 412 125 3.09 / 287.12 5 35
6 8 0.04 263 15.10 323 1283 4.38 / 288.40 5 133
Average= 4.37
(KJ/cycle)

Cycle 64 GMT 22/ 4/2024 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 14 15.10 464 98 0.10 / 279.68 5 8
2 7 2006.52 40 14.70 3196 1879 1.98 / 281.55 8 25
3 13 1394.32 20 14.79 2380 704 2.68 / 282.26 5 34
4 13 575.80 20 14.99 1191 357 3.04 / 282.62 5 40
5 13 63.24 20 15.14 426 129 3.17 / 282.74 5 34
6 8 0.12 263 15.10 323 1283 4.45 / 284.03 5 132
Average= 4.37
(KJ/cycle)

Cycle 63 GMT 17/ 4/2024 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 14 15.11 468 99 0.10 / 275.29 5 8
2 7 2011.64 40 14.68 3266 1918 2.02 / 277.21 8 26
3 13 1238.84 20 14.84 2105 625 2.64 / 277.83 5 34
4 13 581.64 20 15.00 1186 356 3.00 / 278.19 5 38
5 13 54.24 20 15.15 408 124 3.12 / 278.31 5 34
6 8 0.00 263 15.11 319 1268 4.39 / 279.58 5 132
Average= 4.37
(KJ/cycle)

Cycle 62 GMT 12/ 4/2024 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 14 15.11 470 99 0.10 / 270.90 5 8
2 7 2006.44 40 14.69 3233 1900 2.00 / 272.80 8 27
3 13 1218.32 20 14.85 2120 630 2.63 / 273.43 5 35
4 13 568.88 20 15.00 1173 352 2.98 / 273.78 5 37
5 13 45.64 20 15.15 402 122 3.10 / 273.91 5 34
6 8 0.24 263 15.11 323 1284 4.39 / 275.19 5 134
Average= 4.37
(KJ/cycle)

Cycle 61 GMT 7/ 4/2024 14:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 14 15.11 467 99 0.10 / 266.47 5 8
2 7 2006.88 40 14.70 3224 1896 1.99 / 268.37 8 24
3 13 1306.60 20 14.82 2247 666 2.66 / 269.03 5 34
4 13 614.12 20 14.99 1233 370 3.03 / 269.40 5 39
5 13 59.44 20 15.15 418 127 3.16 / 269.53 5 33
6 8 0.12 265 15.11 318 1273 4.43 / 270.80 5 134
Average= 4.37
(KJ/cycle)

Cycle 60 GMT 2/ 4/2024 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 14 15.12 464 98 0.10 / 262.04 5 7
2 7 2009.08 41 14.69 3227 1944 2.04 / 263.99 7 26
3 13 1216.44 20 14.85 2100 624 2.67 / 264.61 5 35
4 13 565.44 20 15.01 1171 352 3.02 / 264.96 5 39
5 13 82.16 20 15.15 448 136 3.15 / 265.10 5 34
6 8 -0.04 263 15.11 321 1276 4.43 / 266.37 5 139
Average= 4.37
(KJ/cycle)

Cycle 59 GMT 28/ 3/2024 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 14 15.11 475 100 0.10 / 257.78 5 7
2 7 1882.80 40 14.74 3047 1797 1.90 / 259.58 7 27
3 13 1210.00 20 14.86 2114 628 2.53 / 260.20 5 34
4 13 563.64 20 15.02 1145 344 2.87 / 260.55 5 37
5 13 52.00 20 15.17 409 124 2.99 / 260.67 5 31
6 8 0.16 263 15.12 320 1272 4.27 / 261.94 5 136
Average= 4.37
(KJ/cycle)

Cycle 58 GMT 23/ 3/2024 11:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 14 15.12 463 98 0.10 / 253.52 5 9
2 7 1860.24 40 14.75 2998 1769 1.87 / 255.29 9 28
3 13 1234.52 20 14.86 2134 634 2.50 / 255.93 5 34
4 13 589.12 20 15.01 1188 357 2.86 / 256.28 5 39
5 13 64.24 20 15.17 418 127 2.98 / 256.41 5 33
6 8 0.08 264 15.12 318 1269 4.25 / 257.68 5 139
Average= 4.37
(KJ/cycle)

Cycle 57 GMT 18/ 3/2024 10:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 14 15.12 464 98 0.10 / 249.11 5 7
2 7 2008.52 40 14.71 3206 1886 1.98 / 250.99 7 26
3 13 1245.96 20 14.84 2144 636 2.62 / 251.63 5 34
4 13 635.36 20 14.99 1266 380 3.00 / 252.01 5 38
5 13 72.40 20 15.16 437 132 3.13 / 252.14 5 33
6 8 0.08 265 15.12 320 1282 4.42 / 253.42 5 137
Average= 4.37
(KJ/cycle)

Cycle 56 GMT 13/ 3/2024 9:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 14 15.13 468 99 0.10 / 244.70 5 7
2 7 2004.28 40 14.71 3204 1885 1.98 / 246.58 7 26
3 13 1267.12 20 14.84 2205 654 2.64 / 247.24 5 35
4 13 590.36 20 15.02 1180 354 2.99 / 247.59 5 38
5 13 115.08 20 15.15 496 150 3.14 / 247.74 5 31
6 8 0.12 266 15.12 315 1267 4.41 / 249.01 5 140
Average= 4.37
(KJ/cycle)

Cycle 55 GMT 8/ 3/2024 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 14 15.13 472 100 0.10 / 240.23 5 8
2 7 2001.72 40 14.71 3196 1881 1.98 / 242.11 8 25
3 13 1420.08 20 14.81 2418 716 2.70 / 242.82 5 33
4 13 615.68 20 15.01 1230 369 3.07 / 243.19 5 39
5 13 136.00 20 15.15 524 159 3.22 / 243.35 5 30
6 8 0.04 265 15.13 311 1247 4.47 / 244.60 5 145
Average= 4.37
(KJ/cycle)

Cycle 54 GMT 3/ 3/2024 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 14 15.14 453 96 0.10 / 235.81 5 7
2 7 2003.00 40 14.72 3153 1856 1.95 / 237.67 7 26
3 13 1298.72 20 14.85 2210 656 2.61 / 238.33 5 34
4 13 642.72 20 15.01 1271 382 2.99 / 238.71 5 37
5 13 165.04 20 15.15 563 171 3.16 / 238.88 5 31
6 8 0.04 265 15.14 311 1248 4.41 / 240.13 5 131
Average= 4.37
(KJ/cycle)

Cycle 53 GMT 27/ 2/2024 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 14 15.14 464 98 0.10 / 231.42 5 8
2 7 2005.76 41 14.71 3211 1937 2.03 / 233.36 8 26
3 13 1231.36 20 14.86 2140 636 2.67 / 233.99 5 35
4 13 552.24 20 15.04 1138 342 3.01 / 234.34 5 33
5 13 160.16 20 15.15 551 167 3.18 / 234.50 5 30
6 8 0.08 263 15.15 305 1215 4.40 / 235.72 5 129
Average= 4.37
(KJ/cycle)

Cycle 52 GMT 22/ 2/2024 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 14 15.13 465 98 0.10 / 227.00 5 7
2 7 2002.28 40 14.72 3205 1887 1.99 / 228.88 7 26
3 13 1288.84 20 14.85 2215 658 2.64 / 229.54 5 34
4 13 672.28 20 15.00 1300 390 3.03 / 229.93 5 36
5 13 100.24 20 15.17 469 142 3.18 / 230.07 5 33
6 8 0.16 265 15.14 311 1248 4.42 / 231.32 5 134
Average= 4.36
(KJ/cycle)

Cycle 51 GMT 17/ 2/2024 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 14 15.14 447 95 0.09 / 222.57 5 8
2 7 2009.80 41 14.72 3169 1913 2.01 / 224.48 8 25
3 13 1280.68 20 14.86 2173 646 2.65 / 225.13 5 33
4 13 585.56 20 15.02 1191 358 3.01 / 225.49 5 39
5 13 97.92 20 15.17 472 143 3.15 / 225.63 5 34
6 8 0.20 265 15.14 316 1268 4.42 / 226.90 5 142
Average= 4.36
(KJ/cycle)

Cycle 50 GMT 12/ 2/2024 5:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 14 15.15 458 97 0.10 / 218.22 5 7
2 7 2008.16 40 14.72 3203 1886 1.98 / 220.11 7 26
3 13 1196.16 20 14.88 2068 615 2.60 / 220.72 5 34
4 13 570.08 20 15.03 1171 352 2.95 / 221.07 5 36
5 13 52.20 20 15.18 406 123 3.07 / 221.20 5 33
6 8 -0.12 265 15.14 319 1280 4.35 / 222.48 5 149
Average= 4.36
(KJ/cycle)

Cycle 49 GMT 7/ 2/2024 4:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 14 15.15 477 101 0.10 / 213.83 5 8
2 7 2009.76 40 14.72 3213 1892 1.99 / 215.72 8 25
3 13 1225.32 20 14.87 2130 633 2.63 / 216.36 5 35
4 13 594.12 20 15.03 1185 356 2.98 / 216.71 5 34
5 13 127.68 20 15.17 514 156 3.14 / 216.87 5 31
6 8 0.04 265 15.14 313 1256 4.39 / 218.12 5 140
Average= 4.36
(KJ/cycle)

Cycle 48 GMT 2/ 2/2024 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 14 15.16 459 97 0.10 / 209.45 5 7
2 7 2002.80 40 14.72 3192 1879 1.98 / 211.33 7 26
3 13 1302.52 20 14.85 2225 661 2.64 / 211.99 5 33
4 13 574.44 20 15.04 1176 354 2.99 / 212.34 5 36
5 13 145.04 20 15.17 528 160 3.15 / 212.50 5 29
6 8 0.04 265 15.16 305 1225 4.38 / 213.73 5 136
Average= 4.36
(KJ/cycle)

Cycle 47 GMT 28/ 1/2024 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 14 15.16 468 99 0.10 / 205.12 5 7
2 7 2005.88 40 14.72 3197 1882 1.98 / 207.00 7 26
3 13 1252.36 20 14.87 2147 639 2.62 / 207.64 5 35
4 13 571.76 20 15.05 1154 347 2.97 / 207.99 5 35
5 13 140.92 20 15.18 527 160 3.13 / 208.15 5 28
6 8 0.08 265 15.16 300 1205 4.33 / 209.35 5 142
Average= 4.36
(KJ/cycle)

Cycle 46 GMT 23/ 1/2024 1:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 14 15.15 476 101 0.10 / 200.69 5 7
2 7 2007.88 40 14.73 3206 1889 1.99 / 202.58 7 25
3 13 1295.40 20 14.86 2220 660 2.65 / 203.24 5 33
4 13 610.36 20 15.03 1222 367 3.02 / 203.61 5 36
5 13 143.24 20 15.17 533 162 3.18 / 203.77 5 29
6 8 0.08 265 15.16 311 1249 4.43 / 205.02 5 142
Average= 4.36
(KJ/cycle)

Cycle 45 GMT 18/ 1/2024 0:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 14 15.19 443 94 0.09 / 196.29 5 7
2 7 2006.96 41 14.72 3185 1922 2.02 / 198.22 7 27
3 13 1223.20 20 14.88 2118 630 2.65 / 198.85 5 34
4 13 565.28 20 15.06 1146 345 2.99 / 199.19 5 37
5 13 137.96 20 15.18 524 159 3.15 / 199.35 5 28
6 8 0.16 265 15.16 309 1241 4.39 / 200.59 5 141
Average= 4.36
(KJ/cycle)

Cycle 44 GMT 13/ 1/2024 0: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 14 15.17 470 100 0.10 / 191.84 5 7
2 7 2004.04 40 14.72 3211 1891 1.99 / 193.73 7 24
3 13 1295.80 20 14.85 2244 666 2.66 / 194.40 5 33
4 13 610.84 20 15.04 1227 369 3.03 / 194.77 5 38
5 13 175.76 20 15.17 584 177 3.20 / 194.95 5 28
6 8 0.04 265 15.16 312 1253 4.46 / 196.20 5 144
Average= 4.36
(KJ/cycle)

Cycle 43 GMT 7/ 1/2024 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 14 15.18 456 97 0.10 / 187.35 5 7
2 7 2008.96 40 14.72 3229 1901 2.00 / 189.25 7 26
3 13 1277.92 20 14.87 2200 654 2.65 / 189.91 5 33
4 13 736.20 20 15.00 1409 423 3.08 / 190.33 5 38
5 13 165.80 20 15.17 566 172 3.25 / 190.50 5 29
6 8 0.04 265 15.17 309 1242 4.49 / 191.74 5 137
Average= 4.36
(KJ/cycle)

Cycle 42 GMT 2/ 1/2024 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 14 15.18 468 99 0.10 / 182.91 5 6
2 7 2003.80 40 14.73 3211 1892 1.99 / 184.81 6 26
3 13 1296.36 20 14.87 2219 660 2.65 / 185.47 5 34
4 13 616.52 20 15.04 1242 374 3.02 / 185.84 5 36
5 13 152.76 20 15.18 548 166 3.19 / 186.01 5 28
6 8 0.12 267 15.17 308 1248 4.44 / 187.25 5 139
Average= 4.35
(KJ/cycle)

Cycle 41 GMT 28/12/2023 21:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 14 15.17 470 100 0.10 / 178.52 5 7
2 7 2003.24 40 14.72 3239 1907 2.01 / 180.42 7 27
3 13 1218.40 20 14.89 2112 629 2.64 / 181.05 5 34
4 13 576.20 20 15.06 1180 355 2.99 / 181.41 5 36
5 13 147.08 20 15.18 540 164 3.16 / 181.57 5 28
6 8 0.04 265 15.17 309 1242 4.40 / 182.81 5 140
Average= 4.35
(KJ/cycle)

Cycle 40 GMT 23/12/2023 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 14 15.17 487 103 0.10 / 173.99 5 7
2 7 2006.48 41 14.73 3221 1945 2.05 / 175.94 7 25
3 13 1305.40 20 14.87 2242 667 2.72 / 176.60 5 36
4 13 677.88 20 15.02 1317 396 3.11 / 177.00 5 39
5 13 149.08 20 15.19 543 165 3.28 / 177.17 5 28
6 8 0.20 267 15.17 309 1252 4.53 / 178.42 5 143
Average= 4.35
(KJ/cycle)

Cycle 39 GMT 18/12/2023 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 14 15.18 460 98 0.10 / 169.49 5 6
2 7 2008.04 41 14.73 3232 1952 2.05 / 171.44 6 25
3 13 1256.24 20 14.89 2176 648 2.70 / 172.09 5 35
4 13 567.08 20 15.06 1167 352 3.05 / 172.44 5 38
5 13 171.12 20 15.18 578 175 3.22 / 172.62 5 30
6 8 0.00 267 15.17 314 1272 4.50 / 173.89 5 146
Average= 4.35
(KJ/cycle)

Cycle 38 GMT 13/12/2023 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 14 15.17 468 99 0.10 / 165.09 5 6
2 7 2008.04 40 14.75 3175 1873 1.97 / 166.96 6 24
3 13 1242.84 20 14.90 2130 635 2.61 / 167.60 5 33
4 13 650.04 20 15.04 1261 379 2.99 / 167.98 5 35
5 13 134.48 20 15.19 518 157 3.14 / 168.13 5 30
6 8 0.16 267 15.17 311 1260 4.40 / 169.39 5 142
Average= 4.34
(KJ/cycle)

Cycle 37 GMT 8/12/2023 17:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 14 15.18 475 101 0.10 / 160.69 5 6
2 7 2003.52 40 14.74 3228 1903 2.00 / 162.60 6 25
3 13 1234.68 20 14.89 2155 642 2.65 / 163.24 5 33
4 13 593.32 20 15.05 1203 362 3.01 / 163.60 5 38
5 13 124.76 20 15.20 508 154 3.16 / 163.75 5 30
6 8 0.12 265 15.18 307 1235 4.40 / 164.99 5 131
Average= 4.34
(KJ/cycle)

Cycle 36 GMT 3/12/2023 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 14 15.19 449 95 0.10 / 156.26 5 6
2 7 2006.68 40 14.75 3190 1882 1.98 / 158.15 6 24
3 13 1294.76 20 14.89 2210 658 2.64 / 158.80 5 33
4 13 643.00 20 15.04 1279 385 3.02 / 159.19 5 37
5 13 132.84 20 15.20 524 159 3.18 / 159.35 5 29
6 8 -0.04 267 15.18 307 1244 4.42 / 160.59 5 136
Average= 4.34
(KJ/cycle)

Cycle 35 GMT 28/11/2023 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 14 15.19 451 96 0.10 / 151.82 5 6
2 7 2003.68 40 14.75 3213 1896 1.99 / 153.72 6 25
3 13 1269.04 20 14.90 2158 643 2.63 / 154.36 5 33
4 13 649.52 20 15.04 1294 389 3.02 / 154.75 5 38
5 13 163.04 20 15.19 563 171 3.19 / 154.92 5 30
6 8 0.16 265 15.19 310 1248 4.44 / 156.17 5 129
Average= 4.34
(KJ/cycle)

Cycle 34 GMT 23/11/2023 15:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 14 15.19 472 100 0.10 / 147.37 5 7
2 7 2007.12 40 14.75 3215 1897 2.00 / 149.26 7 26
3 13 1271.24 20 14.90 2176 648 2.65 / 149.91 5 34
4 13 655.20 20 15.05 1280 385 3.03 / 150.30 5 37
5 13 166.76 20 15.19 571 173 3.20 / 150.47 5 29
6 8 0.16 267 15.19 309 1253 4.46 / 151.72 5 143
Average= 4.33
(KJ/cycle)

Cycle 33 GMT 18/11/2023 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 14 15.20 466 99 0.10 / 142.89 5 6
2 7 2003.32 41 14.76 3166 1916 2.02 / 144.81 6 25
3 13 1257.48 20 14.91 2150 641 2.66 / 145.45 5 34
4 13 674.04 20 15.05 1304 393 3.05 / 145.84 5 36
5 13 177.20 20 15.20 583 177 3.23 / 146.02 5 29
6 13 28.20 20 15.23 352 107 3.33 / 146.13 5 25
7 8 0.04 248 15.19 303 1141 4.47 / 147.27 5 147
Average= 4.33
(KJ/cycle)

Cycle 32 GMT 13/11/2023 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 14 15.20 444 94 0.09 / 138.50 5 6
2 7 2007.84 40 14.77 3179 1878 1.97 / 140.38 6 25
3 13 1270.84 20 14.91 2158 644 2.62 / 141.02 5 33
4 13 598.44 20 15.07 1204 363 2.98 / 141.38 5 37
5 13 177.44 20 15.20 582 177 3.16 / 141.56 5 28
6 8 0.16 267 15.20 304 1234 4.39 / 142.79 5 136
Average= 4.33
(KJ/cycle)

Cycle 31 GMT 8/11/2023 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 13 15.20 475 94 0.09 / 134.04 5 6
2 7 2009.96 40 14.77 3208 1895 1.99 / 135.93 6 25
3 13 1316.16 20 14.89 2266 675 2.66 / 136.61 5 34
4 13 656.00 20 15.05 1286 387 3.05 / 137.00 5 36
5 13 167.80 20 15.20 573 174 3.23 / 137.17 5 30
6 8 0.04 267 15.20 304 1234 4.46 / 138.40 5 132
Average= 4.33
(KJ/cycle)

Cycle 30 GMT 3/11/2023 11:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 13 15.20 457 90 0.09 / 129.68 5 6
2 7 2005.52 40 14.76 3196 1887 1.98 / 131.57 6 26
3 13 1251.24 20 14.91 2177 649 2.63 / 132.22 5 35
4 13 557.52 20 15.09 1140 344 2.97 / 132.56 5 36
5 13 127.88 20 15.22 504 153 3.12 / 132.72 5 28
6 8 0.16 265 15.20 305 1229 4.35 / 133.94 5 147
Average= 4.32
(KJ/cycle)

Cycle 29 GMT 29/10/2023 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 13 15.20 464 92 0.09 / 125.26 5 6
2 7 2009.72 41 14.76 3215 1946 2.04 / 127.20 6 26
3 13 1217.12 20 14.92 2122 633 2.67 / 127.84 5 35
4 13 536.48 20 15.10 1114 336 3.01 / 128.17 5 35
5 13 110.52 20 15.22 492 150 3.16 / 128.32 5 30
6 8 0.12 265 15.19 315 1268 4.42 / 129.59 5 140
Average= 4.32
(KJ/cycle)

Cycle 28 GMT 24/10/2023 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 13 15.20 444 88 0.09 / 120.89 5 6
2 7 2007.16 40 14.77 3182 1880 1.97 / 122.77 6 25
3 13 1160.36 20 14.94 2007 600 2.57 / 123.37 5 34
4 13 603.28 20 15.07 1198 361 2.93 / 123.73 5 36
5 13 85.92 20 15.22 456 139 3.07 / 123.87 5 33
6 8 0.08 267 15.19 320 1298 4.37 / 125.17 5 148
Average= 4.32
(KJ/cycle)

Cycle 27 GMT 19/10/2023 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 13 15.21 460 91 0.09 / 116.53 5 6
2 7 2006.96 40 14.77 3221 1903 1.99 / 118.44 6 24
3 13 1153.04 20 14.94 2016 602 2.60 / 119.04 5 32
4 13 586.52 20 15.08 1182 356 2.95 / 119.40 5 34
5 13 95.92 20 15.22 466 142 3.09 / 119.54 5 31
6 8 0.08 265 15.19 314 1264 4.36 / 120.80 5 136
Average= 4.31
(KJ/cycle)

Cycle 26 GMT 14/10/2023 8: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 13 15.20 459 91 0.09 / 112.13 5 6
2 7 2003.76 41 14.77 3210 1944 2.03 / 114.07 6 22
3 13 1243.64 20 14.93 2108 629 2.66 / 114.70 5 31
4 13 554.64 20 15.10 1138 344 3.01 / 115.04 5 35
5 13 75.76 20 15.23 434 132 3.14 / 115.18 5 29
6 8 -0.04 267 15.20 312 1266 4.41 / 116.44 5 142
Average= 4.31
(KJ/cycle)

Cycle 25 GMT 9/10/2023 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 13 15.21 459 91 0.09 / 107.72 5 6
2 7 2006.12 40 14.77 3238 1913 2.00 / 109.63 6 24
3 13 1261.24 20 14.92 2171 648 2.65 / 110.28 5 32
4 13 526.08 20 15.10 1096 331 2.98 / 110.61 5 37
5 13 50.52 20 15.24 402 123 3.11 / 110.73 5 31
6 13 29.56 20 15.24 373 114 3.22 / 110.85 5 32
7 8 0.04 246 15.19 319 1192 4.41 / 112.04 5 143
Average= 4.31
(KJ/cycle)

Cycle 24 GMT 4/10/2023 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 13 15.20 470 93 0.09 / 103.34 5 5
2 7 2008.56 40 14.79 3208 1898 1.99 / 105.24 5 24
3 13 1252.04 20 14.93 2155 643 2.63 / 105.88 5 32
4 13 554.76 20 15.09 1144 345 2.98 / 106.23 5 38
5 13 44.08 20 15.24 395 120 3.10 / 106.35 5 32
6 8 0.04 265 15.20 317 1277 4.38 / 107.63 5 138
Average= 4.31
(KJ/cycle)

Cycle 23 GMT 29/ 9/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 13 15.20 461 91 0.09 / 98.95 5 6
2 7 2008.12 40 14.80 3170 1877 1.97 / 100.83 6 24
3 13 1223.04 20 14.94 2102 628 2.60 / 101.45 5 32
4 13 563.32 20 15.09 1168 353 2.95 / 101.81 5 35
5 13 45.36 20 15.24 402 123 3.07 / 101.93 5 33
6 13 25.72 20 15.24 374 114 3.18 / 102.04 5 33
7 8 -0.08 246 15.19 323 1207 4.39 / 103.25 5 138
Average= 4.30
(KJ/cycle)

Cycle 22 GMT 24/ 9/2023 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 13 15.20 448 89 0.09 / 94.54 5 6
2 7 2005.80 40 14.79 3227 1909 2.00 / 96.45 6 24
3 13 1189.36 20 14.95 2068 618 2.62 / 97.07 5 33
4 13 547.36 20 15.10 1137 343 2.96 / 97.41 5 37
5 13 60.32 20 15.24 419 128 3.09 / 97.54 5 35
6 13 17.08 20 15.24 358 109 3.20 / 97.65 5 34
7 8 0.04 246 15.19 324 1211 4.41 / 98.86 5 141
Average= 4.30
(KJ/cycle)

Cycle 21 GMT 19/ 9/2023 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 13 15.21 461 91 0.09 / 90.13 5 6
2 7 2005.92 40 14.80 3187 1887 1.98 / 92.02 6 24
3 13 1250.04 20 14.95 2133 638 2.62 / 92.66 5 33
4 13 561.64 20 15.10 1156 349 2.96 / 93.01 5 38
5 13 41.72 20 15.24 401 122 3.09 / 93.13 5 34
6 13 13.04 20 15.25 352 107 3.19 / 93.24 5 34
7 8 0.00 246 15.20 325 1215 4.41 / 94.45 5 138
Average= 4.29
(KJ/cycle)

Cycle 20 GMT 14/ 9/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 13 15.21 452 89 0.09 / 85.70 5 6
2 7 2003.76 40 14.80 3220 1906 2.00 / 87.61 6 24
3 13 1229.12 20 14.95 2132 637 2.63 / 88.25 5 32
4 13 543.20 20 15.11 1122 339 2.97 / 88.59 5 37
5 13 37.88 20 15.25 391 119 3.09 / 88.71 5 33
6 13 11.20 20 15.25 350 107 3.20 / 88.81 5 33
7 8 0.00 248 15.20 326 1229 4.43 / 90.04 5 141
Average= 4.29
(KJ/cycle)

Cycle 19 GMT 9/ 9/2023 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 13 15.21 459 91 0.09 / 81.28 5 6
2 7 2004.20 40 14.81 3197 1894 1.98 / 83.18 6 22
3 13 1255.52 20 14.94 2183 652 2.64 / 83.83 5 30
4 13 569.44 20 15.10 1165 352 2.99 / 84.18 5 36
5 13 41.76 20 15.25 390 119 3.11 / 84.30 5 32
6 13 12.64 20 15.25 345 105 3.21 / 84.40 5 32
7 8 -0.04 248 15.20 321 1210 4.42 / 85.61 5 142
Average= 4.28
(KJ/cycle)

Cycle 18 GMT 4/ 9/2023 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 13 15.21 452 89 0.09 / 76.93 5 6
2 7 2007.16 40 14.81 3168 1877 1.97 / 78.81 6 24
3 13 1172.40 20 14.97 2027 607 2.57 / 79.41 5 32
4 13 562.32 20 15.11 1152 348 2.92 / 79.76 5 39
5 13 38.64 20 15.26 385 118 3.04 / 79.88 5 34
6 8 0.16 267 15.21 323 1312 4.35 / 81.19 5 143
Average= 4.27
(KJ/cycle)

Cycle 17 GMT 29/ 8/2023 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 13 15.22 458 91 0.09 / 72.57 5 6
2 7 2002.52 40 14.81 3218 1906 2.00 / 74.47 6 26
3 13 1172.12 20 14.96 2052 614 2.61 / 75.09 5 35
4 13 558.64 20 15.11 1153 348 2.96 / 75.43 5 38
5 13 33.24 20 15.26 383 117 3.08 / 75.55 5 35
6 8 0.00 265 15.21 320 1290 4.37 / 76.84 5 137
Average= 4.27
(KJ/cycle)

Cycle 16 GMT 24/ 8/2023 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 13 15.22 456 90 0.09 / 68.21 5 6
2 7 2006.52 40 14.81 3206 1899 1.99 / 70.10 6 26
3 13 1210.92 20 14.96 2107 630 2.62 / 70.74 5 35
4 13 529.36 20 15.13 1092 330 2.95 / 71.07 5 37
5 13 48.52 20 15.26 397 121 3.07 / 71.19 5 34
6 13 13.88 20 15.26 347 106 3.18 / 71.29 5 34
7 8 0.00 246 15.21 316 1182 4.36 / 72.47 5 139
Average= 4.26
(KJ/cycle)

Cycle 15 GMT 19/ 8/2023 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 13 15.23 447 89 0.09 / 63.79 5 6
2 7 2003.36 40 14.82 3163 1875 1.96 / 65.66 6 26
3 13 1261.12 20 14.96 2159 646 2.61 / 66.31 5 33
4 13 606.88 20 15.11 1212 366 2.98 / 66.67 5 39
5 13 39.04 20 15.26 389 119 3.09 / 66.79 5 34
6 13 10.64 20 15.26 350 107 3.20 / 66.90 5 34
7 8 -0.12 248 15.21 322 1215 4.42 / 68.12 5 145
Average= 4.26
(KJ/cycle)

Cycle 14 GMT 14/ 8/2023 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 13 15.24 453 90 0.09 / 59.36 5 6
2 7 2007.76 40 14.82 3215 1906 2.00 / 61.27 6 26
3 13 1289.00 20 14.94 2231 667 2.66 / 61.93 5 34
4 13 518.12 20 15.13 1083 328 2.99 / 62.26 5 38
5 13 49.04 20 15.26 398 121 3.11 / 62.38 5 33
6 13 13.28 20 15.27 348 106 3.22 / 62.49 5 32
7 8 0.08 248 15.22 321 1212 4.43 / 63.70 5 135
Average= 4.25
(KJ/cycle)

Cycle 13 GMT 9/ 8/2023 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 13 15.23 474 94 0.09 / 54.93 5 6
2 7 2002.72 40 14.82 3194 1893 1.99 / 56.82 6 26
3 13 1227.12 20 14.96 2122 635 2.62 / 57.46 5 35
4 13 571.88 20 15.12 1179 357 2.98 / 57.81 5 38
5 13 133.60 20 15.24 527 161 3.14 / 57.97 5 32
6 13 31.64 20 15.27 366 112 3.25 / 58.09 5 28
7 8 0.08 250 15.23 311 1184 4.44 / 59.27 5 143
Average= 4.23
(KJ/cycle)

Cycle 12 GMT 4/ 8/2023 18:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 13 15.24 481 95 0.10 / 50.40 5 6
2 7 2008.40 40 14.82 3231 1915 2.01 / 52.32 6 26
3 13 1260.92 20 14.96 2173 650 2.66 / 52.97 5 34
4 13 680.56 20 15.09 1316 397 3.06 / 53.37 5 37
5 13 137.16 20 15.25 528 161 3.22 / 53.53 5 31
6 13 29.08 20 15.27 364 111 3.33 / 53.64 5 28
7 8 0.08 250 15.23 314 1196 4.53 / 54.83 5 134
Average= 4.22
(KJ/cycle)

Cycle 11 GMT 30/ 7/2023 18: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 13 15.23 466 92 0.09 / 45.98 5 6
2 7 2005.36 40 14.83 3214 1907 2.00 / 47.88 6 26
3 13 1240.56 20 14.97 2139 640 2.64 / 48.52 5 34
4 13 522.84 20 15.14 1103 334 2.97 / 48.86 5 37
5 13 127.72 20 15.26 513 157 3.13 / 49.01 5 31
6 13 26.20 20 15.28 355 108 3.24 / 49.12 5 28
7 8 0.08 250 15.23 312 1188 4.43 / 50.31 5 140
Average= 4.19
(KJ/cycle)

Cycle 10 GMT 25/ 7/2023 16:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 13 15.23 477 94 0.09 / 41.50 5 6
2 7 2005.60 41 14.83 3196 1943 2.04 / 43.45 6 25
3 13 1208.28 20 14.98 2088 626 2.66 / 44.07 5 35
4 13 568.36 20 15.13 1169 354 3.02 / 44.42 5 38
5 13 89.72 20 15.26 460 140 3.16 / 44.57 5 33
6 13 25.72 20 15.27 369 113 3.27 / 44.68 5 31
7 8 0.04 248 15.23 319 1205 4.47 / 45.88 5 136
Average= 4.17
(KJ/cycle)

Cycle 9 GMT 20/ 7/2023 15:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 13 15.23 456 90 0.09 / 37.04 5 6
2 7 2005.28 40 14.84 3215 1908 2.00 / 38.94 6 26
3 13 1221.12 20 14.97 2142 641 2.64 / 39.59 5 36
4 13 583.00 20 15.12 1198 362 3.00 / 39.95 5 40
5 13 61.32 20 15.27 423 129 3.13 / 40.08 5 36
6 13 18.44 20 15.27 362 111 3.24 / 40.19 5 35
7 8 0.12 248 15.23 323 1220 4.46 / 41.41 5 136
Average= 4.14
(KJ/cycle)

Cycle 8 GMT 15/ 7/2023 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 13 15.23 480 95 0.10 / 32.70 5 6
2 7 2007.80 40 14.84 3214 1908 2.00 / 34.61 6 27
3 13 1073.68 20 15.02 1891 568 2.57 / 35.18 5 37
4 13 514.24 20 15.14 1090 330 2.90 / 35.51 5 39
5 13 37.64 20 15.27 395 121 3.02 / 35.63 5 37
6 8 3.76 265 15.23 326 1316 4.34 / 36.95 5 133
Average= 4.11
(KJ/cycle)

Cycle 7 GMT 10/ 7/2023 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 13 15.24 446 88 0.09 / 28.26 5 6
2 7 2003.72 40 14.84 3228 1916 2.00 / 30.18 6 27
3 13 1187.96 20 14.99 2081 624 2.63 / 30.80 5 36
4 13 494.32 20 15.15 1066 323 2.95 / 31.12 5 39
5 13 62.60 20 15.26 434 132 3.08 / 31.26 5 38
6 13 12.84 20 15.27 359 110 3.19 / 31.37 5 38
7 8 0.00 248 15.22 329 1242 4.44 / 32.61 5 150
Average= 4.08
(KJ/cycle)

Cycle 6 GMT 5/ 7/2023 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 13 15.25 449 89 0.09 / 23.87 5 6
2 7 2002.84 40 14.84 3218 1910 2.00 / 25.78 6 28
3 13 1188.52 20 14.99 2056 616 2.62 / 26.40 5 36
4 13 553.12 20 15.14 1132 343 2.96 / 26.74 5 36
5 13 112.36 20 15.26 497 152 3.11 / 26.89 5 32
6 13 21.08 20 15.28 350 107 3.22 / 27.00 5 29
7 8 0.16 248 15.24 310 1172 4.39 / 28.17 5 138
Average= 4.02
(KJ/cycle)

Cycle 5 GMT 30/ 6/2023 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 13 15.25 483 96 0.10 / 19.44 5 6
2 7 2005.80 40 14.86 3192 1897 1.99 / 21.34 6 27
3 13 1293.88 20 14.97 2219 664 2.66 / 22.00 5 35
4 13 530.04 20 15.16 1109 336 2.99 / 22.34 5 37
5 13 153.40 20 15.27 542 166 3.16 / 22.50 5 29
6 13 22.80 20 15.29 350 107 3.27 / 22.61 5 26
7 8 0.08 250 15.25 308 1174 4.44 / 23.78 5 146
Average= 3.96
(KJ/cycle)

Cycle 4 GMT 25/ 6/2023 10: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 13 15.25 466 92 0.09 / 14.94 5 6
2 7 2002.28 40 14.86 3168 1883 1.98 / 16.82 6 26
3 13 1252.88 20 14.99 2135 640 2.62 / 17.46 5 34
4 13 681.60 20 15.12 1311 396 3.01 / 17.86 5 35
5 13 195.60 20 15.25 601 183 3.20 / 18.04 5 30
6 13 20.64 20 15.29 344 105 3.30 / 18.15 5 26
7 8 0.12 253 15.25 310 1196 4.50 / 19.34 5 141
Average= 3.87
(KJ/cycle)

Cycle 3 GMT 20/ 6/2023 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 13 15.25 442 88 0.09 / 10.55 5 6
2 7 2002.56 40 14.85 3204 1903 1.99 / 12.45 6 27
3 13 1204.80 20 14.99 2100 630 2.62 / 13.08 5 35
4 13 497.20 20 15.18 1050 319 2.94 / 13.40 5 35
5 13 194.72 20 15.25 605 185 3.12 / 13.59 5 30
6 8 0.08 270 15.26 306 1261 4.38 / 14.85 5 137
Average= 3.71
(KJ/cycle)

Cycle 2 GMT 15/ 6/2023 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 12 15.23 451 82 0.08 / 6.16 5 6
2 3 1544.00 1 15.10 2567 39 0.12 / 6.19 5 21
3 7 2005.20 40 14.87 3173 1887 2.01 / 8.08 21 27
4 13 1235.96 20 14.99 2141 642 2.65 / 8.72 5 36
5 13 539.96 20 15.17 1106 336 2.99 / 9.06 5 36
6 13 153.48 20 15.26 540 165 3.15 / 9.22 5 29
7 8 0.08 270 15.25 301 1239 4.39 / 10.46 5 145
Average= 3.49
(KJ/cycle)

Cycle 1 GMT 10/ 6/2023 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 18 15.40 438 121 0.12 / 1.80 6 6
2 3 1240.20 -4 15.59 0 0 0.00 / 1.80 6 6
3 7 2005.76 40 14.86 3162 1879 2.00 / 3.68 6 23
4 13 1252.52 20 14.97 2146 643 2.64 / 4.32 5 32
5 13 529.92 20 15.15 1098 333 2.98 / 4.66 5 32
6 13 181.96 20 15.24 586 179 3.15 / 4.83 5 29
7 13 16.28 20 15.27 334 102 3.26 / 4.94 5 25
8 8 0.08 253 15.23 295 1137 4.39 / 6.07 5 138
Average= 3.04
(KJ/cycle)

Cycle 0 GMT 5/ 6/2023 5:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.88 18 15.57 389 109 0.11 / 0.11 5 7
2 7 88.48 40 15.55 404 251 0.36 / 0.36 7 9
3 13 118.76 20 15.53 451 140 0.50 / 0.50 5 9
4 13 89.88 20 15.52 402 125 0.63 / 0.63 5 10
5 8 0.16 257 15.48 265 1054 1.68 / 1.68 6 146
Average= 1.68
(KJ/cycle)