SIO Argo Site:
Pump Diagnostics Page   



Serial= 7805 WMO= 3902347

Return

←PreviousNext→

Cycle 18 GMT 22/ 4/2025 20:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 33 15.15 415 207 0.21 / 69.27 7 7
2 7 2002.36 40 14.78 2565 1516 1.72 / 70.79 7 24
3 13 1396.52 20 14.88 1919 571 2.30 / 71.36 6 32
4 13 825.48 20 14.99 1267 380 2.67 / 71.74 6 36
5 13 141.64 20 15.19 456 139 2.81 / 71.88 6 26
6 13 42.60 20 15.21 330 100 2.91 / 71.98 6 23
7 8 0.08 293 15.17 275 1222 4.14 / 73.20 6 154
Average= 3.85
(KJ/cycle)

Cycle 17 GMT 12/ 4/2025 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 32 15.15 416 202 0.20 / 65.14 7 7
2 7 2004.72 40 14.78 2583 1527 1.73 / 66.67 7 24
3 13 1315.40 20 14.90 1828 545 2.27 / 67.22 6 32
4 13 874.84 20 14.98 1324 397 2.67 / 67.61 6 36
5 13 178.00 20 15.18 499 151 2.82 / 67.76 6 27
6 13 56.84 20 15.21 346 105 2.93 / 67.87 6 24
7 8 0.08 291 15.17 271 1196 4.12 / 69.07 6 146
Average= 3.84
(KJ/cycle)

Cycle 16 GMT 2/ 4/2025 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 15.15 412 200 0.20 / 61.02 7 7
2 7 2013.32 40 14.78 2595 1534 1.73 / 62.55 24 25
3 13 1338.04 20 14.89 1860 554 2.29 / 63.10 6 32
4 13 773.44 20 15.02 1209 363 2.65 / 63.47 6 35
5 13 180.24 20 15.19 499 152 2.80 / 63.62 6 29
6 13 50.80 20 15.22 334 102 2.90 / 63.72 6 26
7 8 0.04 293 15.17 275 1222 4.13 / 64.94 6 153
Average= 3.82
(KJ/cycle)

Cycle 15 GMT 23/ 3/2025 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 32 15.15 399 193 0.19 / 56.83 7 7
2 7 2010.04 40 14.78 2599 1537 1.73 / 58.37 7 24
3 13 1305.04 20 14.91 1812 540 2.27 / 58.91 6 32
4 13 845.08 20 15.00 1291 387 2.66 / 59.29 6 36
5 13 228.88 20 15.17 569 173 2.83 / 59.47 6 30
6 13 54.36 20 15.22 349 106 2.94 / 59.57 6 28
7 8 0.04 291 15.17 282 1245 4.18 / 60.82 6 142
Average= 3.80
(KJ/cycle)

Cycle 14 GMT 12/ 3/2025 17:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 32 15.16 417 202 0.20 / 52.77 7 7
2 7 2005.28 40 14.79 2564 1517 1.72 / 54.29 7 24
3 13 1298.36 20 14.92 1791 534 2.25 / 54.82 6 33
4 13 738.40 20 15.04 1170 352 2.61 / 55.17 6 36
5 13 144.36 20 15.20 462 140 2.75 / 55.31 6 28
6 13 38.12 20 15.22 327 100 2.85 / 55.41 6 27
7 8 0.08 289 15.17 279 1223 4.07 / 56.64 6 138
Average= 3.78
(KJ/cycle)

Cycle 13 GMT 2/ 3/2025 11: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 32 15.18 388 188 0.19 / 48.67 7 7
2 7 2008.36 40 14.79 2591 1533 1.72 / 50.20 7 26
3 13 1329.92 20 14.90 1842 549 2.27 / 50.75 6 33
4 13 873.32 20 14.99 1329 398 2.67 / 51.15 6 37
5 13 145.32 20 15.21 458 139 2.81 / 51.29 6 29
6 13 35.32 20 15.23 323 98 2.91 / 51.39 6 26
7 8 0.08 289 15.18 269 1180 4.09 / 52.57 6 135
Average= 3.75
(KJ/cycle)

Cycle 12 GMT 20/ 2/2025 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 15.16 403 196 0.20 / 44.52 7 7
2 7 2003.20 40 14.80 2581 1528 1.72 / 46.05 21 26
3 13 1545.48 20 14.87 2088 621 2.34 / 46.67 6 30
4 13 828.60 20 15.02 1277 384 2.73 / 47.06 6 36
5 13 146.80 20 15.22 449 137 2.86 / 47.19 6 27
6 13 37.08 20 15.24 320 98 2.96 / 47.29 6 25
7 8 0.20 291 15.19 269 1189 4.15 / 48.48 6 142
Average= 3.73
(KJ/cycle)

Cycle 11 GMT 9/ 2/2025 21:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 32 15.17 413 200 0.20 / 40.33 7 7
2 7 2009.52 40 14.81 2589 1534 1.73 / 41.86 7 26
3 13 1453.04 20 14.89 1986 591 2.33 / 42.45 6 32
4 13 838.72 20 15.02 1277 384 2.71 / 42.84 6 35
5 13 223.72 20 15.19 557 169 2.88 / 43.00 6 30
6 13 55.32 20 15.23 341 104 2.98 / 43.11 6 27
7 8 0.16 291 15.19 276 1220 4.20 / 44.33 6 136
Average= 3.69
(KJ/cycle)

Cycle 10 GMT 30/ 1/2025 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 15.17 402 195 0.20 / 36.16 7 7
2 7 2005.28 41 14.81 2595 1576 1.77 / 37.74 7 25
3 13 1414.56 20 14.90 1940 578 2.35 / 38.32 6 33
4 13 828.08 20 15.03 1270 382 2.73 / 38.70 6 36
5 13 124.84 20 15.23 433 132 2.86 / 38.83 6 27
6 13 33.68 20 15.25 317 97 2.96 / 38.93 6 25
7 8 0.12 287 15.20 275 1200 4.16 / 40.13 6 146
Average= 3.65
(KJ/cycle)

Cycle 9 GMT 20/ 1/2025 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 15.18 406 197 0.20 / 31.97 7 7
2 7 2001.72 40 14.81 2579 1528 1.73 / 33.49 7 25
3 13 1518.00 20 14.88 2055 612 2.34 / 34.11 6 31
4 13 904.20 20 15.01 1356 407 2.74 / 34.51 6 36
5 13 174.00 20 15.22 500 152 2.90 / 34.67 6 30
6 13 38.40 20 15.25 326 99 3.00 / 34.76 6 27
7 8 0.00 289 15.19 274 1203 4.20 / 35.97 6 132
Average= 3.60
(KJ/cycle)

Cycle 8 GMT 10/ 1/2025 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 32 15.19 401 195 0.19 / 27.81 7 7
2 7 2005.12 40 14.82 2575 1526 1.72 / 29.34 7 27
3 13 1418.84 20 14.91 1938 578 2.30 / 29.91 6 32
4 13 828.16 20 15.03 1272 382 2.68 / 30.30 6 37
5 13 216.32 20 15.20 553 168 2.85 / 30.46 6 31
6 13 22.60 20 15.25 302 92 2.94 / 30.56 6 28
7 8 0.08 287 15.20 278 1213 4.15 / 31.77 6 135
Average= 3.53
(KJ/cycle)

Cycle 7 GMT 30/12/2024 19:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 32 15.18 409 199 0.20 / 23.69 7 7
2 3 1020.08 1 15.24 1455 22 0.22 / 23.71 6 24
3 7 2005.88 41 14.82 2586 1571 1.79 / 25.28 24 23
4 13 1302.76 20 14.94 1810 541 2.33 / 25.82 6 32
5 13 840.64 20 15.03 1279 384 2.72 / 26.21 6 37
6 13 128.40 20 15.24 421 128 2.85 / 26.34 6 26
7 13 31.76 20 15.25 313 95 2.94 / 26.43 6 25
8 8 0.08 289 15.21 269 1182 4.12 / 27.61 6 139
Average= 3.45
(KJ/cycle)

Cycle 6 GMT 20/12/2024 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 31 15.20 398 188 0.19 / 19.50 7 7
2 3 1035.12 1 15.21 1495 23 0.21 / 19.52 6 26
3 7 2006.56 41 14.82 2589 1573 1.78 / 21.10 26 25
4 13 1400.68 20 14.92 1927 575 2.36 / 21.67 6 31
5 13 814.60 20 15.04 1260 379 2.74 / 22.05 6 35
6 13 113.88 20 15.24 418 127 2.86 / 22.18 6 27
7 13 28.88 20 15.26 310 95 2.96 / 22.27 6 26
8 8 0.08 289 15.21 277 1218 4.18 / 23.49 6 147
Average= 3.36
(KJ/cycle)

Cycle 5 GMT 10/12/2024 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 15.20 392 185 0.18 / 15.31 7 8
2 7 2002.80 40 14.83 2584 1533 1.72 / 16.85 8 25
3 13 1531.84 20 14.90 2072 617 2.33 / 17.46 6 32
4 13 874.84 20 15.03 1321 397 2.73 / 17.86 6 37
5 13 159.76 20 15.24 480 146 2.88 / 18.01 6 28
6 13 19.52 20 15.27 306 93 2.97 / 18.10 6 26
7 8 -0.04 289 15.21 276 1213 4.19 / 19.31 6 135
Average= 3.22
(KJ/cycle)

Cycle 4 GMT 30/11/2024 0:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 30 15.20 397 181 0.18 / 11.63 7 7
2 3 1023.72 1 15.22 1472 22 0.20 / 11.65 6 26
3 7 1520.00 40 15.00 2054 1232 1.44 / 12.89 26 25
4 13 1108.92 20 15.05 1588 478 1.91 / 13.36 6 30
5 13 766.36 20 15.10 1197 361 2.28 / 13.73 6 34
6 13 129.76 20 15.26 442 135 2.41 / 13.86 6 28
7 8 0.16 304 15.23 274 1269 3.68 / 15.13 6 130
Average= 3.03
(KJ/cycle)

Cycle 3 GMT 28/11/2024 14:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 15.19 382 174 0.17 / 7.97 7 7
2 7 1521.44 40 15.00 2052 1231 1.41 / 9.20 7 25
3 13 1320.88 20 15.01 1825 548 1.95 / 9.75 6 30
4 13 621.36 20 15.15 1023 310 2.26 / 10.06 6 32
5 13 80.96 20 15.28 375 115 2.38 / 10.18 6 27
6 13 18.12 20 15.28 296 90 2.47 / 10.27 6 24
7 8 0.08 287 15.23 271 1185 3.65 / 11.45 6 149
Average= 2.86
(KJ/cycle)

Cycle 2 GMT 27/11/2024 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.23 394 186 0.19 / 4.28 7 8
2 7 1511.44 40 15.01 2030 1219 1.40 / 5.50 8 25
3 13 1202.52 20 15.03 1704 512 1.92 / 6.01 6 29
4 13 855.84 20 15.07 1310 395 2.31 / 6.41 6 33
5 13 101.48 20 15.27 403 123 2.43 / 6.53 6 27
6 8 0.04 306 15.23 272 1268 3.70 / 7.80 6 148
Average= 2.60
(KJ/cycle)

Cycle 1 GMT 25/11/2024 18:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 31 15.37 392 187 0.19 / 1.83 7 7
2 7 968.44 40 15.15 1427 865 1.05 / 2.70 7 26
3 13 115.08 20 15.33 417 128 1.18 / 2.83 6 24
4 13 26.08 20 15.34 308 94 1.27 / 2.92 6 26
5 8 0.04 287 15.28 268 1175 2.45 / 4.09 6 141
Average= 2.05
(KJ/cycle)

Cycle 0 GMT 25/11/2024 8:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.64 30 15.54 323 151 0.15 / 0.15 7 8
2 7 76.84 41 15.52 342 218 0.37 / 0.37 8 10
3 13 54.04 20 15.51 308 96 0.46 / 0.46 7 9
4 8 0.32 306 15.45 250 1182 1.65 / 1.65 7 173
Average= 1.65
(KJ/cycle)