SIO Argo Site:
Pump Diagnostics Page   



Serial= 7887 WMO= 3902346

Return

←PreviousNext→

Cycle 14 GMT 13/ 3/2025 15:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 31 14.84 511 235 0.24 / 64.61 5 5
2 7 2008.68 40 14.41 3560 2052 2.29 / 66.67 5 13
3 13 1303.28 20 14.52 2450 711 3.00 / 67.38 4 18
4 13 860.60 20 14.60 1765 515 3.51 / 67.89 4 22
5 13 173.76 20 14.85 620 184 3.70 / 68.08 5 15
6 13 43.44 20 14.89 398 119 3.82 / 68.20 5 14
7 8 -0.04 270 14.86 318 1276 5.09 / 69.47 5 147
Average= 4.63
(KJ/cycle)

Cycle 13 GMT 3/ 3/2025 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 31 14.86 487 224 0.22 / 59.53 5 5
2 7 2005.04 40 14.42 3537 2040 2.26 / 61.57 5 12
3 13 1314.44 20 14.52 2486 722 2.99 / 62.29 4 18
4 13 877.28 20 14.60 1783 521 3.51 / 62.81 4 22
5 13 168.12 20 14.85 609 181 3.69 / 62.99 5 15
6 13 49.80 20 14.90 404 120 3.81 / 63.11 5 13
7 8 0.08 270 14.87 316 1269 5.08 / 64.38 5 143
Average= 4.60
(KJ/cycle)

Cycle 12 GMT 21/ 2/2025 2: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 14.86 491 233 0.23 / 54.44 5 5
2 7 2004.08 40 14.41 3557 2050 2.28 / 56.49 5 12
3 13 1398.84 20 14.50 2608 756 3.04 / 57.25 4 19
4 13 788.84 20 14.64 1628 477 3.52 / 57.72 4 22
5 13 179.24 20 14.85 636 189 3.71 / 57.91 5 18
6 13 22.48 20 14.90 369 110 3.82 / 58.02 5 14
7 8 0.12 270 14.86 319 1280 5.10 / 59.30 5 131
Average= 4.56
(KJ/cycle)

Cycle 11 GMT 10/ 2/2025 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 32 14.86 481 229 0.23 / 49.37 5 5
2 7 2004.72 40 14.42 3557 2052 2.28 / 51.42 5 12
3 13 1380.68 20 14.50 2592 752 3.03 / 52.17 4 20
4 13 816.32 20 14.62 1686 493 3.53 / 52.67 4 21
5 13 128.16 20 14.88 542 161 3.69 / 52.83 5 15
6 13 33.80 20 14.91 386 115 3.80 / 52.94 5 14
7 8 -0.04 267 14.87 318 1263 5.06 / 54.21 5 144
Average= 4.52
(KJ/cycle)

Cycle 10 GMT 31/ 1/2025 12:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 14.86 509 242 0.24 / 44.26 5 5
2 7 2007.08 41 14.41 3576 2113 2.35 / 46.37 5 13
3 13 1318.40 20 14.53 2475 719 3.07 / 47.09 4 19
4 13 746.08 20 14.66 1571 461 3.53 / 47.55 4 21
5 13 165.60 20 14.86 616 183 3.72 / 47.73 5 15
6 13 42.16 20 14.90 401 119 3.84 / 47.85 5 13
7 8 -0.08 267 14.87 325 1290 5.13 / 49.14 5 132
Average= 4.47
(KJ/cycle)

Cycle 9 GMT 21/ 1/2025 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 31 14.85 521 240 0.24 / 39.20 5 5
2 7 2006.68 40 14.43 3545 2046 2.29 / 41.25 5 12
3 13 1232.56 20 14.54 2356 685 2.97 / 41.93 4 19
4 13 792.44 20 14.64 1647 482 3.45 / 42.41 4 21
5 13 179.36 20 14.85 644 191 3.64 / 42.61 5 17
6 13 37.76 20 14.90 391 117 3.76 / 42.72 5 15
7 8 -0.08 270 14.87 322 1293 5.05 / 44.01 5 142
Average= 4.40
(KJ/cycle)

Cycle 8 GMT 10/ 1/2025 23:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 14.85 488 225 0.22 / 34.10 5 5
2 7 2006.48 40 14.43 3549 2048 2.27 / 36.15 5 14
3 13 1411.24 20 14.51 2643 767 3.04 / 36.91 4 18
4 13 748.20 20 14.66 1584 464 3.50 / 37.38 4 21
5 13 170.44 20 14.87 614 183 3.69 / 37.56 5 15
6 13 44.88 20 14.91 403 120 3.81 / 37.68 5 13
7 8 0.08 270 14.87 319 1281 5.09 / 38.96 5 131
Average= 4.33
(KJ/cycle)

Cycle 7 GMT 31/12/2024 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 14.87 489 225 0.23 / 28.99 5 5
2 7 2007.20 40 14.45 3538 2045 2.27 / 31.04 5 15
3 13 1304.08 20 14.54 2457 714 2.98 / 31.75 4 18
4 13 846.56 20 14.63 1731 506 3.49 / 32.26 4 21
5 13 228.40 20 14.84 724 215 3.71 / 32.47 5 17
6 13 31.04 20 14.91 373 111 3.82 / 32.58 5 13
7 8 0.08 274 14.88 316 1288 5.11 / 33.87 5 134
Average= 4.23
(KJ/cycle)

Cycle 6 GMT 21/12/2024 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 31 14.87 503 232 0.23 / 23.76 5 5
2 3 1025.36 1 14.86 1970 29 0.26 / 23.79 4 5
3 7 2005.92 40 14.45 3533 2042 2.30 / 25.83 5 13
4 13 1421.48 20 14.51 2658 771 3.07 / 26.60 4 20
5 13 936.76 20 14.61 1874 548 3.62 / 27.15 4 21
6 13 206.08 20 14.86 665 198 3.82 / 27.35 5 17
7 13 46.28 20 14.91 399 119 3.94 / 27.46 5 14
8 8 0.08 276 14.88 317 1302 5.24 / 28.77 5 147
Average= 4.11
(KJ/cycle)

Cycle 5 GMT 11/12/2024 3:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 14.86 512 236 0.24 / 18.73 5 5
2 7 2006.84 40 14.45 3535 2043 2.28 / 20.77 5 12
3 13 1297.32 20 14.55 2438 709 2.99 / 21.48 4 19
4 13 746.68 20 14.67 1564 459 3.45 / 21.94 4 21
5 13 161.16 20 14.88 594 177 3.62 / 22.12 5 15
6 13 13.76 20 14.92 357 107 3.73 / 22.22 5 13
7 8 0.00 276 14.88 317 1302 5.03 / 23.53 5 136
Average= 3.92
(KJ/cycle)

Cycle 4 GMT 30/11/2024 21:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 31 14.86 520 240 0.24 / 14.14 5 5
2 7 1517.40 40 14.64 2770 1622 1.86 / 15.76 5 13
3 13 1421.52 20 14.62 2622 767 2.63 / 16.53 4 14
4 13 672.16 20 14.76 1427 421 3.05 / 16.95 4 19
5 13 170.24 20 14.91 603 180 3.23 / 17.13 5 14
6 8 0.12 293 14.91 313 1367 4.60 / 18.49 5 148
Average= 3.70
(KJ/cycle)

Cycle 3 GMT 29/11/2024 11:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 31 14.85 515 237 0.24 / 9.69 5 5
2 7 1508.12 40 14.64 2766 1620 1.86 / 11.31 5 13
3 13 1104.20 20 14.67 2132 626 2.48 / 11.94 4 17
4 13 660.68 20 14.76 1408 416 2.90 / 12.36 4 19
5 13 152.88 20 14.90 575 171 3.07 / 12.53 5 14
6 8 0.12 291 14.90 316 1370 4.44 / 13.90 5 141
Average= 3.47
(KJ/cycle)

Cycle 2 GMT 28/11/2024 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 31 14.89 487 225 0.22 / 5.14 5 5
2 7 1518.20 40 14.65 2778 1628 1.85 / 6.77 5 12
3 13 1215.48 20 14.65 2308 676 2.53 / 7.45 4 16
4 13 749.16 20 14.72 1577 464 2.99 / 7.91 4 18
5 13 152.08 20 14.90 576 172 3.16 / 8.08 5 15
6 8 0.04 293 14.90 315 1375 4.54 / 9.46 5 137
Average= 3.15
(KJ/cycle)

Cycle 1 GMT 26/11/2024 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 31 15.01 465 216 0.22 / 2.21 5 5
2 7 976.60 40 14.78 1921 1136 1.35 / 3.35 5 16
3 13 185.52 20 14.96 638 191 1.54 / 3.54 5 14
4 8 0.08 291 14.95 317 1379 2.92 / 4.92 5 136
Average= 2.46
(KJ/cycle)

Cycle 0 GMT 26/11/2024 5:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.32 30 15.21 566 258 0.26 / 0.26 5 5
2 7 178.72 40 15.19 580 352 0.61 / 0.61 5 6
3 13 116.04 20 15.17 473 144 0.75 / 0.75 5 6
4 8 0.28 289 15.12 284 1241 2.00 / 2.00 5 132
Average= 2.00
(KJ/cycle)