SIO Argo Site:
Pump Diagnostics Page   



Serial= 3229 WMO= 3902311

Return

←PreviousNext→

Cycle 28 GMT 15/12/2024 1:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 15.15 449 204 0.20 / 110.65 2 4
2 3 985.96 -1 15.57 0 0 0.00 / 110.65 2 4
3 7 2003.36 38 14.90 2931 1660 1.86 / 112.31 2 16
4 13 1460.04 18 14.96 2290 617 2.48 / 112.92 2 19
5 13 856.96 18 15.06 1514 410 2.89 / 113.33 2 22
6 13 251.16 18 15.21 681 186 3.08 / 113.52 2 20
7 13 45.52 18 15.25 390 107 3.18 / 113.63 2 23
8 13 26.24 18 15.23 358 98 3.28 / 113.73 2 22
9 8 -0.08 165 15.20 305 765 4.05 / 114.49 2 22
Average= 3.95
(KJ/cycle)

Cycle 27 GMT 5/12/2024 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 29 15.17 438 193 0.19 / 106.57 2 6
2 3 981.84 -1 15.55 0 0 0.00 / 106.57 2 6
3 3 1035.48 1 15.26 1791 27 0.22 / 106.60 2 17
4 7 2010.36 38 14.90 2938 1663 1.88 / 108.26 2 16
5 13 1411.36 18 14.98 2226 600 2.48 / 108.86 2 19
6 13 873.80 18 15.07 1546 419 2.90 / 109.28 2 22
7 13 226.84 18 15.22 657 180 3.08 / 109.46 2 20
8 13 51.68 18 15.24 401 110 3.19 / 109.57 2 23
9 13 36.72 18 15.23 377 103 3.30 / 109.68 2 20
10 8 -0.12 165 15.20 306 767 4.06 / 110.44 2 9
Average= 3.94
(KJ/cycle)

Cycle 26 GMT 25/11/2024 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 29 15.17 439 193 0.19 / 102.51 2 4
2 3 987.08 -1 15.54 0 0 0.00 / 102.51 2 4
3 3 1039.72 1 15.26 1796 27 0.22 / 102.54 2 17
4 7 2003.84 38 14.92 2933 1663 1.88 / 104.20 2 17
5 13 1460.92 18 14.98 2281 615 2.50 / 104.82 2 19
6 13 863.08 18 15.07 1509 409 2.91 / 105.23 2 22
7 13 215.96 18 15.22 636 174 3.08 / 105.40 2 20
8 13 55.52 18 15.25 405 111 3.19 / 105.51 2 21
9 13 41.08 18 15.25 385 106 3.30 / 105.62 2 20
10 8 -0.12 165 15.21 304 763 4.06 / 106.38 2 8
Average= 3.94
(KJ/cycle)

Cycle 25 GMT 15/11/2024 16:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.17 453 199 0.20 / 98.44 2 5
2 7 2004.00 38 14.92 2928 1660 1.86 / 100.10 2 16
3 13 1458.44 18 14.98 2295 619 2.48 / 100.72 2 20
4 13 863.04 18 15.08 1523 413 2.89 / 101.14 2 21
5 13 258.28 18 15.22 695 190 3.08 / 101.33 2 21
6 13 50.28 18 15.26 400 110 3.19 / 101.44 2 13
7 13 39.88 18 15.26 382 105 3.30 / 101.54 2 12
8 8 0.04 165 15.21 309 775 4.07 / 102.32 2 22
Average= 3.94
(KJ/cycle)

Cycle 24 GMT 5/11/2024 22: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 29 15.17 443 195 0.19 / 94.31 2 5
2 7 2011.16 38 14.93 2940 1668 1.86 / 95.97 2 17
3 13 1414.28 18 15.00 2231 602 2.47 / 96.58 2 20
4 13 916.44 18 15.08 1579 429 2.89 / 97.00 2 22
5 13 345.24 18 15.20 831 227 3.12 / 97.23 2 21
6 13 47.44 18 15.27 401 110 3.23 / 97.34 2 16
7 13 37.32 18 15.27 389 107 3.34 / 97.45 2 17
8 8 -0.04 165 15.22 317 796 4.13 / 98.25 2 20
Average= 3.93
(KJ/cycle)

Cycle 23 GMT 27/10/2024 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 29 15.18 447 197 0.20 / 90.22 2 4
2 7 2003.20 38 14.94 2932 1665 1.86 / 91.88 2 16
3 13 1427.36 18 14.99 2239 604 2.47 / 92.48 2 19
4 13 885.24 18 15.08 1547 420 2.89 / 92.90 2 21
5 13 322.76 18 15.21 787 215 3.10 / 93.12 2 22
6 13 51.28 18 15.26 404 111 3.21 / 93.23 2 19
7 13 41.56 18 15.25 390 107 3.32 / 93.34 2 15
8 8 0.00 165 15.21 308 773 4.09 / 94.11 2 13
Average= 3.92
(KJ/cycle)

Cycle 22 GMT 17/10/2024 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 29 15.19 472 208 0.21 / 86.10 2 5
2 7 2004.88 39 14.94 2950 1719 1.93 / 87.82 2 17
3 13 1411.92 18 15.00 2225 601 2.53 / 88.42 2 20
4 13 822.16 18 15.10 1469 399 2.93 / 88.82 2 21
5 13 274.36 18 15.23 725 199 3.13 / 89.02 2 21
6 13 50.20 18 15.27 404 111 3.24 / 89.13 2 21
7 13 40.84 18 15.26 393 108 3.34 / 89.24 2 19
8 8 -0.12 165 15.22 312 784 4.13 / 90.02 2 15
Average= 3.91
(KJ/cycle)

Cycle 21 GMT 7/10/2024 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.20 488 215 0.22 / 81.94 2 5
2 7 2009.76 38 14.93 2958 1678 1.89 / 83.62 2 17
3 13 1470.56 18 14.99 2317 625 2.52 / 84.24 2 20
4 13 916.48 18 15.07 1602 435 2.95 / 84.68 2 22
5 13 298.32 18 15.21 764 209 3.16 / 84.89 2 21
6 13 46.84 18 15.26 406 112 3.27 / 85.00 2 20
7 13 29.00 18 15.25 373 102 3.38 / 85.10 2 22
8 8 0.04 165 15.21 315 791 4.17 / 85.89 2 12
Average= 3.90
(KJ/cycle)

Cycle 20 GMT 27/ 9/2024 18:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 15.19 428 189 0.19 / 77.86 2 5
2 7 2007.96 38 14.94 2933 1665 1.85 / 79.53 2 16
3 13 1515.28 18 14.99 2340 631 2.49 / 80.16 2 20
4 13 856.24 18 15.11 1496 407 2.89 / 80.57 2 22
5 13 305.00 18 15.23 751 206 3.10 / 80.77 2 22
6 13 40.88 18 15.28 376 103 3.20 / 80.87 2 19
7 13 26.96 18 15.28 347 95 3.30 / 80.97 2 21
8 8 0.00 165 15.23 300 754 4.05 / 81.72 2 14
Average= 3.89
(KJ/cycle)

Cycle 19 GMT 17/ 9/2024 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.20 428 189 0.19 / 73.76 2 5
2 7 2012.48 39 14.93 2949 1717 1.91 / 75.47 2 16
3 13 1388.36 18 15.02 2188 592 2.50 / 76.06 2 20
4 13 957.32 18 15.07 1623 440 2.94 / 76.51 2 22
5 13 335.48 18 15.21 792 217 3.15 / 76.72 2 22
6 13 55.36 18 15.27 396 109 3.26 / 76.83 2 21
7 13 43.00 18 15.26 371 102 3.37 / 76.93 2 20
8 8 -0.24 165 15.22 295 741 4.11 / 77.67 2 24
Average= 3.88
(KJ/cycle)

Cycle 18 GMT 8/ 9/2024 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 15.21 423 187 0.19 / 69.75 2 4
2 7 2008.84 38 14.95 2937 1669 1.86 / 71.41 2 16
3 13 1410.12 18 15.02 2215 599 2.45 / 72.01 2 19
4 13 875.72 18 15.10 1523 414 2.87 / 72.43 2 21
5 13 269.88 18 15.25 703 193 3.06 / 72.62 2 21
6 13 60.12 18 15.29 404 111 3.17 / 72.73 2 21
7 13 48.16 18 15.27 379 104 3.28 / 72.84 2 18
8 8 0.12 165 15.24 291 732 4.01 / 73.57 2 20
Average= 3.87
(KJ/cycle)

Cycle 17 GMT 29/ 8/2024 9:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 15.20 420 185 0.19 / 65.65 2 5
2 7 2006.80 39 14.97 2931 1711 1.90 / 67.36 2 16
3 13 1453.20 18 15.02 2268 613 2.51 / 67.97 2 19
4 13 897.56 18 15.12 1553 423 2.93 / 68.40 2 22
5 13 319.72 18 15.24 772 212 3.14 / 68.61 2 22
6 13 54.12 18 15.29 396 109 3.25 / 68.72 2 18
7 13 44.84 18 15.29 377 104 3.36 / 68.82 2 21
8 8 -0.04 165 15.24 294 739 4.10 / 69.56 2 12
Average= 3.86
(KJ/cycle)

Cycle 16 GMT 19/ 8/2024 14:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 15.21 420 185 0.19 / 61.60 2 4
2 7 2008.88 38 14.95 2942 1671 1.86 / 63.27 2 16
3 13 1571.36 18 15.00 2422 654 2.51 / 63.92 2 18
4 13 857.96 18 15.12 1500 408 2.92 / 64.33 2 22
5 13 255.32 18 15.26 679 187 3.11 / 64.52 2 21
6 13 56.04 18 15.29 399 110 3.22 / 64.63 2 19
7 13 43.16 18 15.28 373 103 3.32 / 64.73 2 19
8 8 -0.04 165 15.24 291 732 4.05 / 65.46 2 20
Average= 3.85
(KJ/cycle)

Cycle 15 GMT 9/ 8/2024 19:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 15.21 421 186 0.19 / 57.55 2 5
2 7 2009.88 38 14.95 2943 1672 1.86 / 59.22 2 16
3 13 1461.32 18 15.02 2271 614 2.47 / 59.84 2 20
4 13 948.20 18 15.10 1623 441 2.91 / 60.28 2 22
5 13 227.44 18 15.26 645 177 3.09 / 60.46 2 21
6 13 56.40 18 15.29 400 110 3.20 / 60.57 2 19
7 13 48.24 18 15.28 383 105 3.31 / 60.67 2 19
8 8 -0.08 165 15.24 295 742 4.05 / 61.41 2 12
Average= 3.84
(KJ/cycle)

Cycle 14 GMT 31/ 7/2024 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 15.21 417 178 0.18 / 53.53 2 4
2 7 2010.80 38 14.96 2941 1672 1.85 / 55.20 2 16
3 13 1415.76 18 15.03 2217 600 2.45 / 55.80 2 19
4 13 866.48 18 15.12 1508 410 2.86 / 56.21 2 21
5 13 309.92 18 15.25 758 208 3.07 / 56.42 2 22
6 13 50.28 18 15.29 390 107 3.18 / 56.53 2 17
7 13 40.68 18 15.28 369 101 3.28 / 56.63 2 18
8 8 0.00 165 15.24 294 739 4.02 / 57.37 2 17
Average= 3.82
(KJ/cycle)

Cycle 13 GMT 21/ 7/2024 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 28 15.21 422 180 0.18 / 49.49 2 4
2 7 2003.60 38 14.97 2939 1672 1.85 / 51.16 2 16
3 13 1466.16 18 15.02 2284 618 2.47 / 51.78 2 19
4 13 918.60 18 15.11 1579 429 2.90 / 52.21 2 21
5 13 302.64 18 15.24 747 205 3.10 / 52.41 2 21
6 13 48.24 18 15.29 384 106 3.21 / 52.52 2 20
7 13 38.08 18 15.28 362 100 3.31 / 52.62 2 16
8 8 -0.04 165 15.24 291 732 4.04 / 53.35 2 15
Average= 3.81
(KJ/cycle)

Cycle 12 GMT 11/ 7/2024 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 15.21 425 181 0.18 / 45.49 2 4
2 7 2010.36 38 14.96 2944 1674 1.85 / 47.16 2 16
3 13 1417.52 18 15.04 2227 603 2.46 / 47.77 2 19
4 13 824.24 18 15.14 1451 395 2.85 / 48.16 2 21
5 13 313.20 18 15.25 761 209 3.06 / 48.37 2 21
6 13 58.20 18 15.29 398 110 3.17 / 48.48 2 18
7 13 48.56 18 15.28 378 104 3.28 / 48.58 2 19
8 8 0.12 165 15.25 289 727 4.00 / 49.31 2 16
Average= 3.79
(KJ/cycle)

Cycle 11 GMT 1/ 7/2024 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 28 15.22 428 182 0.18 / 41.43 2 5
2 7 2006.32 39 14.97 2940 1716 1.90 / 43.15 2 16
3 13 1402.32 18 15.04 2208 598 2.50 / 43.75 2 19
4 13 907.80 18 15.11 1567 426 2.92 / 44.17 2 21
5 13 236.24 18 15.27 653 179 3.10 / 44.35 2 21
6 13 69.28 18 15.29 419 115 3.22 / 44.47 2 19
7 13 47.92 18 15.29 380 105 3.32 / 44.57 2 20
8 8 0.04 165 15.24 292 734 4.06 / 45.31 2 17
Average= 3.78
(KJ/cycle)

Cycle 10 GMT 21/ 6/2024 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 15.23 418 178 0.18 / 37.47 2 4
2 7 2008.56 38 14.98 2945 1676 1.85 / 39.15 2 15
3 13 1405.92 18 15.04 2205 597 2.45 / 39.75 2 19
4 13 768.68 18 15.14 1378 376 2.83 / 40.12 2 21
5 13 269.00 18 15.26 694 191 3.02 / 40.31 2 21
6 13 58.04 18 15.31 397 109 3.13 / 40.42 2 20
7 13 47.64 18 15.28 375 103 3.23 / 40.52 2 20
8 8 -0.12 165 15.25 289 727 3.96 / 41.25 2 21
Average= 3.75
(KJ/cycle)

Cycle 9 GMT 12/ 6/2024 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 15.24 426 182 0.18 / 33.38 2 4
2 3 1017.52 1 15.32 1758 27 0.21 / 33.41 2 14
3 7 2008.44 38 14.99 2941 1675 1.88 / 35.08 2 15
4 13 1510.88 18 15.03 2344 634 2.52 / 35.72 2 19
5 13 948.68 18 15.12 1622 441 2.96 / 36.16 2 21
6 13 274.72 18 15.29 703 193 3.15 / 36.35 2 21
7 13 50.88 18 15.32 388 107 3.26 / 36.46 2 17
8 13 44.80 18 15.30 375 103 3.36 / 36.56 2 20
9 8 0.00 165 15.27 291 733 4.10 / 37.29 2 20
Average= 3.73
(KJ/cycle)

Cycle 8 GMT 2/ 6/2024 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 29 15.24 422 187 0.19 / 28.79 2 4
2 3 923.16 -1 15.65 0 0 0.00 / 28.79 2 4
3 7 2008.52 74 14.87 2926 3220 3.41 / 32.01 2 16
4 13 395.68 18 15.26 873 240 3.65 / 32.25 2 21
5 13 53.96 18 15.32 388 107 3.75 / 32.36 2 19
6 13 37.52 18 15.32 363 100 3.85 / 32.46 2 16
7 8 -0.16 165 15.28 292 736 4.59 / 33.20 2 12
Average= 3.69
(KJ/cycle)

Cycle 7 GMT 23/ 5/2024 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 27 15.23 443 182 0.18 / 24.51 2 4
2 3 1024.96 1 15.34 1770 27 0.21 / 24.54 2 15
3 7 1806.08 74 14.92 2669 2947 3.16 / 27.49 2 16
4 13 244.44 18 15.29 663 182 3.34 / 27.67 2 20
5 13 48.80 18 15.33 386 107 3.45 / 27.78 2 17
6 13 40.36 18 15.31 367 101 3.55 / 27.88 2 17
7 8 0.04 165 15.28 290 731 4.28 / 28.61 2 18
Average= 3.58
(KJ/cycle)

Cycle 6 GMT 22/ 5/2024 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 27 15.26 445 183 0.18 / 20.25 2 4
2 7 1788.32 75 14.93 2647 2964 3.15 / 23.21 2 16
3 13 261.92 18 15.27 683 188 3.34 / 23.40 2 20
4 13 42.76 18 15.32 372 103 3.44 / 23.50 2 18
5 13 29.20 18 15.31 347 96 3.53 / 23.60 2 19
6 8 -0.04 165 15.26 292 735 4.27 / 24.33 2 13
Average= 3.48
(KJ/cycle)

Cycle 5 GMT 21/ 5/2024 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 27 15.23 421 173 0.17 / 16.43 2 4
2 7 1525.32 74 15.03 2310 2569 2.74 / 19.00 2 17
3 13 113.92 18 15.32 474 131 2.87 / 19.13 2 18
4 13 41.92 18 15.33 372 103 2.98 / 19.23 2 19
5 13 23.32 18 15.32 336 93 3.07 / 19.32 2 16
6 8 0.08 165 15.28 293 739 3.81 / 20.06 2 11
Average= 3.34
(KJ/cycle)

Cycle 4 GMT 20/ 5/2024 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 26 15.24 447 177 0.18 / 12.54 2 4
2 3 1028.40 1 15.34 1792 27 0.20 / 12.57 2 15
3 7 1526.32 74 15.05 2319 2583 2.79 / 15.15 2 16
4 13 205.92 18 15.31 604 166 2.95 / 15.32 2 19
5 13 40.92 18 15.34 373 103 3.06 / 15.42 2 17
6 13 24.80 18 15.34 343 95 3.15 / 15.52 2 16
7 8 -0.08 165 15.29 292 737 3.89 / 16.26 2 18
Average= 3.25
(KJ/cycle)

Cycle 3 GMT 19/ 5/2024 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 23 15.24 426 149 0.15 / 8.60 2 4
2 10 1012.88 3 15.28 1743 80 0.23 / 8.68 2 10
3 3 1023.28 1 15.34 1783 27 0.26 / 8.70 2 16
4 7 1507.28 75 15.04 2289 2582 2.84 / 11.29 2 17
5 13 143.60 18 15.33 518 143 2.98 / 11.43 2 19
6 13 45.52 18 15.34 378 104 3.09 / 11.53 2 16
7 13 25.52 18 15.33 344 95 3.18 / 11.63 2 15
8 8 0.04 165 15.29 293 739 3.92 / 12.37 2 20
Average= 3.09
(KJ/cycle)

Cycle 2 GMT 18/ 5/2024 9: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 32 15.29 435 213 0.21 / 4.77 2 4
2 3 772.24 -4 15.67 0 0 0.00 / 4.77 2 4
3 3 874.20 -2 15.68 0 0 0.00 / 4.77 2 4
4 7 1514.92 75 15.06 2303 2601 2.81 / 7.37 2 17
5 13 117.84 18 15.34 484 134 2.95 / 7.50 2 19
6 13 40.88 18 15.35 377 104 3.05 / 7.60 2 18
7 13 20.40 18 15.34 338 93 3.15 / 7.70 2 12
8 8 0.08 165 15.29 297 749 3.89 / 8.45 2 24
Average= 2.82
(KJ/cycle)

Cycle 1 GMT 17/ 5/2024 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 15.44 389 162 0.16 / 1.82 3 3
2 3 963.28 -1 15.68 0 0 0.00 / 1.82 3 3
3 7 1007.44 74 15.22 1653 1862 2.02 / 3.68 2 19
4 13 33.48 18 15.40 370 103 2.13 / 3.78 2 16
5 8 -0.24 165 15.34 305 772 2.90 / 4.55 2 15
Average= 2.28
(KJ/cycle)

Cycle 0 GMT 16/ 5/2024 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 93.64 26 15.64 389 158 0.16 / 0.16 3 3
2 7 108.88 75 15.60 403 472 0.63 / 0.63 3 5
3 13 24.56 18 15.59 291 82 0.71 / 0.71 3 3
4 8 0.12 240 15.53 253 943 1.65 / 1.65 3 13
Average= 1.65
(KJ/cycle)