SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 15.16 | 429 | 195 | 0.20 / 139.31 | 2 | 7 |
2 | 3 | 1057.88 | 2 | 15.14 | 1704 | 52 | 0.25 / 139.37 | 2 | 9 |
3 | 7 | 2007.52 | 38 | 15.19 | 1587 | 916 | 1.16 / 140.28 | 2 | 4 |
4 | 13 | 1966.00 | 18 | 15.17 | 1366 | 373 | 1.54 / 140.65 | 2 | 2 |
5 | 13 | 1874.28 | 18 | 15.18 | 1123 | 307 | 1.84 / 140.96 | 2 | 4 |
6 | 13 | 1629.52 | 18 | 14.97 | 1806 | 487 | 2.33 / 141.45 | 2 | 13 |
7 | 13 | 1309.28 | 18 | 15.03 | 1303 | 353 | 2.68 / 141.80 | 2 | 12 |
8 | 13 | 1057.16 | 18 | 15.06 | 1107 | 300 | 2.98 / 142.10 | 2 | 7 |
9 | 13 | 738.60 | 18 | 15.07 | 945 | 256 | 3.24 / 142.36 | 2 | 15 |
10 | 13 | 366.80 | 18 | 15.15 | 563 | 154 | 3.39 / 142.51 | 2 | 18 |
11 | 13 | 28.92 | 18 | 15.22 | 291 | 80 | 3.47 / 142.59 | 3 | 15 |
12 | 13 | 16.80 | 18 | 15.22 | 261 | 72 | 3.54 / 142.66 | 4 | 14 |
13 | 8 | 0.12 | 165 | 15.19 | 246 | 617 | 4.16 / 143.28 | 4 | 48 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 30 | 15.16 | 429 | 195 | 0.20 / 135.47 | 2 | 8 |
2 | 7 | 2003.24 | 38 | 14.87 | 2728 | 1541 | 1.74 / 137.01 | 2 | 19 |
3 | 13 | 1518.12 | 18 | 14.90 | 2186 | 586 | 2.32 / 137.60 | 2 | 23 |
4 | 13 | 970.36 | 18 | 14.98 | 1536 | 414 | 2.74 / 138.01 | 2 | 26 |
5 | 13 | 413.08 | 18 | 15.12 | 841 | 229 | 2.97 / 138.24 | 2 | 28 |
6 | 13 | 35.20 | 18 | 15.21 | 349 | 96 | 3.06 / 138.33 | 3 | 25 |
7 | 13 | 14.40 | 18 | 15.21 | 321 | 88 | 3.15 / 138.42 | 4 | 23 |
8 | 8 | 0.04 | 165 | 15.19 | 278 | 697 | 3.85 / 139.12 | 4 | 204 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 30 | 15.18 | 442 | 201 | 0.20 / 131.70 | 2 | 8 |
2 | 7 | 2006.88 | 38 | 14.87 | 2722 | 1538 | 1.74 / 133.24 | 2 | 18 |
3 | 13 | 1505.92 | 18 | 14.89 | 2156 | 578 | 2.32 / 133.82 | 2 | 23 |
4 | 13 | 1017.44 | 18 | 14.98 | 1542 | 416 | 2.73 / 134.24 | 2 | 23 |
5 | 13 | 461.92 | 18 | 15.11 | 889 | 242 | 2.97 / 134.48 | 2 | 27 |
6 | 13 | 24.28 | 18 | 15.22 | 333 | 91 | 3.07 / 134.57 | 3 | 22 |
7 | 8 | 0.00 | 165 | 15.19 | 281 | 704 | 3.77 / 135.27 | 3 | 75 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 30 | 15.18 | 427 | 194 | 0.19 / 127.93 | 2 | 8 |
2 | 7 | 2004.80 | 39 | 14.86 | 2722 | 1578 | 1.77 / 129.51 | 2 | 18 |
3 | 13 | 1579.72 | 18 | 14.89 | 2238 | 600 | 2.37 / 130.11 | 2 | 23 |
4 | 13 | 1022.08 | 18 | 14.98 | 1516 | 409 | 2.78 / 130.52 | 2 | 22 |
5 | 13 | 377.68 | 18 | 15.14 | 767 | 209 | 2.99 / 130.73 | 2 | 26 |
6 | 13 | 23.20 | 18 | 15.23 | 320 | 88 | 3.08 / 130.81 | 3 | 22 |
7 | 8 | 0.16 | 165 | 15.20 | 275 | 690 | 3.77 / 131.50 | 3 | 104 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 30 | 15.19 | 438 | 200 | 0.20 / 124.23 | 2 | 7 |
2 | 7 | 2003.76 | 38 | 14.86 | 2714 | 1533 | 1.73 / 125.77 | 2 | 18 |
3 | 13 | 1510.08 | 18 | 14.92 | 2134 | 573 | 2.31 / 126.34 | 2 | 21 |
4 | 13 | 917.36 | 18 | 15.02 | 1404 | 380 | 2.68 / 126.72 | 2 | 22 |
5 | 13 | 490.80 | 18 | 15.11 | 879 | 239 | 2.92 / 126.96 | 2 | 22 |
6 | 13 | 24.44 | 18 | 15.23 | 326 | 89 | 3.01 / 127.05 | 3 | 23 |
7 | 8 | 0.08 | 165 | 15.20 | 274 | 687 | 3.70 / 127.74 | 4 | 81 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 30 | 15.17 | 451 | 205 | 0.21 / 120.59 | 2 | 9 |
2 | 7 | 2002.52 | 38 | 14.86 | 2717 | 1534 | 1.74 / 122.12 | 2 | 18 |
3 | 13 | 1378.36 | 18 | 14.97 | 1891 | 510 | 2.25 / 122.63 | 2 | 20 |
4 | 13 | 968.16 | 18 | 15.01 | 1472 | 398 | 2.65 / 123.03 | 2 | 25 |
5 | 13 | 471.88 | 18 | 15.11 | 860 | 234 | 2.88 / 123.26 | 2 | 23 |
6 | 13 | 32.16 | 18 | 15.23 | 336 | 92 | 2.97 / 123.35 | 3 | 24 |
7 | 8 | 0.08 | 165 | 15.20 | 272 | 682 | 3.65 / 124.04 | 3 | 84 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 30 | 15.20 | 423 | 193 | 0.19 / 116.81 | 2 | 9 |
2 | 7 | 2002.12 | 38 | 14.89 | 2727 | 1543 | 1.74 / 118.36 | 2 | 18 |
3 | 13 | 1554.24 | 18 | 14.93 | 2150 | 578 | 2.31 / 118.93 | 2 | 20 |
4 | 13 | 1001.56 | 18 | 15.03 | 1490 | 403 | 2.72 / 119.34 | 2 | 23 |
5 | 13 | 558.84 | 18 | 15.12 | 962 | 262 | 2.98 / 119.60 | 2 | 22 |
6 | 13 | 30.56 | 18 | 15.25 | 335 | 92 | 3.07 / 119.69 | 3 | 24 |
7 | 8 | 0.08 | 165 | 15.21 | 275 | 690 | 3.76 / 120.38 | 4 | 75 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 30 | 15.18 | 436 | 199 | 0.20 / 112.96 | 2 | 9 |
2 | 7 | 2004.28 | 38 | 14.91 | 2727 | 1545 | 1.74 / 114.51 | 2 | 18 |
3 | 13 | 1629.08 | 18 | 14.91 | 2300 | 617 | 2.36 / 115.12 | 2 | 22 |
4 | 13 | 1098.52 | 18 | 14.99 | 1639 | 442 | 2.80 / 115.56 | 2 | 22 |
5 | 13 | 576.96 | 18 | 15.12 | 1000 | 272 | 3.08 / 115.84 | 2 | 23 |
6 | 13 | 27.36 | 18 | 15.25 | 327 | 90 | 3.17 / 115.93 | 3 | 23 |
7 | 8 | 0.08 | 165 | 15.22 | 276 | 693 | 3.86 / 116.62 | 3 | 74 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 30 | 15.19 | 433 | 197 | 0.20 / 109.24 | 2 | 9 |
2 | 7 | 2006.20 | 38 | 14.90 | 2720 | 1540 | 1.74 / 110.78 | 2 | 18 |
3 | 13 | 1480.40 | 18 | 14.93 | 2134 | 573 | 2.31 / 111.36 | 2 | 23 |
4 | 13 | 934.72 | 18 | 15.03 | 1432 | 387 | 2.70 / 111.74 | 2 | 23 |
5 | 13 | 443.04 | 18 | 15.14 | 843 | 230 | 2.93 / 111.97 | 2 | 25 |
6 | 13 | 32.32 | 18 | 15.24 | 325 | 89 | 3.02 / 112.06 | 3 | 18 |
7 | 8 | 0.16 | 165 | 15.22 | 278 | 698 | 3.72 / 112.76 | 4 | 70 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 30 | 15.19 | 449 | 205 | 0.20 / 105.53 | 2 | 9 |
2 | 7 | 2005.08 | 38 | 14.89 | 2737 | 1549 | 1.75 / 107.08 | 2 | 18 |
3 | 13 | 1429.80 | 18 | 14.96 | 2079 | 560 | 2.31 / 107.64 | 2 | 23 |
4 | 13 | 904.64 | 18 | 15.03 | 1445 | 391 | 2.70 / 108.03 | 2 | 26 |
5 | 13 | 421.72 | 18 | 15.15 | 839 | 229 | 2.93 / 108.26 | 2 | 27 |
6 | 13 | 21.36 | 18 | 15.25 | 326 | 89 | 3.02 / 108.35 | 3 | 23 |
7 | 8 | 0.12 | 165 | 15.23 | 276 | 694 | 3.72 / 109.05 | 4 | 83 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 30 | 15.21 | 434 | 198 | 0.20 / 101.79 | 2 | 9 |
2 | 7 | 2007.20 | 38 | 14.90 | 2730 | 1546 | 1.74 / 103.33 | 2 | 18 |
3 | 13 | 1520.24 | 18 | 14.94 | 2195 | 590 | 2.33 / 103.92 | 2 | 23 |
4 | 13 | 928.84 | 18 | 15.03 | 1478 | 400 | 2.73 / 104.32 | 2 | 26 |
5 | 13 | 383.44 | 18 | 15.16 | 794 | 217 | 2.95 / 104.54 | 2 | 27 |
6 | 13 | 27.48 | 18 | 15.26 | 334 | 92 | 3.04 / 104.63 | 3 | 23 |
7 | 8 | 0.04 | 165 | 15.22 | 279 | 701 | 3.74 / 105.33 | 4 | 90 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 30 | 15.19 | 435 | 198 | 0.20 / 98.01 | 2 | 9 |
2 | 7 | 2004.40 | 39 | 14.91 | 2720 | 1582 | 1.78 / 99.59 | 2 | 18 |
3 | 13 | 1464.64 | 18 | 14.95 | 2116 | 569 | 2.35 / 100.16 | 2 | 23 |
4 | 13 | 937.04 | 18 | 15.04 | 1483 | 401 | 2.75 / 100.56 | 2 | 26 |
5 | 13 | 395.28 | 18 | 15.16 | 807 | 220 | 2.97 / 100.78 | 2 | 27 |
6 | 13 | 27.52 | 18 | 15.27 | 336 | 92 | 3.06 / 100.88 | 3 | 23 |
7 | 8 | 0.16 | 165 | 15.23 | 283 | 711 | 3.77 / 101.59 | 4 | 97 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 30 | 15.19 | 439 | 200 | 0.20 / 94.23 | 2 | 9 |
2 | 7 | 2003.20 | 38 | 14.91 | 2738 | 1551 | 1.75 / 95.78 | 2 | 19 |
3 | 13 | 1417.56 | 18 | 14.96 | 2064 | 556 | 2.31 / 96.34 | 2 | 23 |
4 | 13 | 988.48 | 18 | 15.02 | 1555 | 420 | 2.73 / 96.76 | 2 | 26 |
5 | 13 | 527.48 | 18 | 15.12 | 971 | 264 | 2.99 / 97.02 | 2 | 28 |
6 | 13 | 24.76 | 18 | 15.25 | 326 | 89 | 3.08 / 97.11 | 3 | 23 |
7 | 8 | 0.16 | 165 | 15.23 | 279 | 701 | 3.78 / 97.81 | 3 | 89 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 30 | 15.20 | 430 | 196 | 0.20 / 90.51 | 2 | 10 |
2 | 7 | 2004.40 | 38 | 14.88 | 2734 | 1546 | 1.74 / 92.06 | 2 | 18 |
3 | 13 | 1467.16 | 18 | 14.94 | 2120 | 570 | 2.31 / 92.63 | 2 | 23 |
4 | 13 | 916.44 | 18 | 15.02 | 1457 | 394 | 2.71 / 93.02 | 2 | 26 |
5 | 13 | 375.00 | 18 | 15.15 | 785 | 214 | 2.92 / 93.24 | 2 | 27 |
6 | 13 | 22.16 | 18 | 15.24 | 335 | 92 | 3.01 / 93.33 | 3 | 22 |
7 | 8 | 0.04 | 165 | 15.22 | 280 | 703 | 3.72 / 94.03 | 3 | 90 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 30 | 15.20 | 436 | 199 | 0.20 / 86.79 | 2 | 10 |
2 | 7 | 2003.80 | 38 | 14.89 | 2730 | 1545 | 1.74 / 88.33 | 2 | 18 |
3 | 13 | 1424.60 | 18 | 14.95 | 2072 | 558 | 2.30 / 88.89 | 2 | 24 |
4 | 13 | 936.20 | 18 | 15.04 | 1491 | 404 | 2.70 / 89.29 | 2 | 26 |
5 | 13 | 400.04 | 18 | 15.16 | 818 | 223 | 2.93 / 89.52 | 2 | 27 |
6 | 13 | 27.24 | 18 | 15.25 | 333 | 91 | 3.02 / 89.61 | 3 | 23 |
7 | 8 | 0.12 | 165 | 15.22 | 281 | 706 | 3.73 / 90.32 | 5 | 88 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 30 | 15.21 | 449 | 205 | 0.20 / 82.94 | 2 | 10 |
2 | 7 | 2005.48 | 38 | 14.92 | 2741 | 1554 | 1.76 / 84.50 | 2 | 19 |
3 | 13 | 1480.48 | 18 | 14.95 | 2150 | 579 | 2.34 / 85.07 | 2 | 23 |
4 | 13 | 996.80 | 18 | 15.03 | 1566 | 424 | 2.76 / 85.50 | 2 | 26 |
5 | 13 | 476.32 | 18 | 15.14 | 927 | 253 | 3.01 / 85.75 | 2 | 28 |
6 | 13 | 62.36 | 18 | 15.25 | 394 | 108 | 3.12 / 85.86 | 3 | 27 |
7 | 8 | 0.08 | 165 | 15.23 | 291 | 731 | 3.85 / 86.59 | 4 | 103 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 30 | 15.21 | 429 | 196 | 0.20 / 79.05 | 2 | 10 |
2 | 7 | 2006.48 | 38 | 14.91 | 2743 | 1554 | 1.75 / 80.60 | 2 | 19 |
3 | 13 | 1639.92 | 18 | 14.93 | 2320 | 623 | 2.37 / 81.23 | 2 | 23 |
4 | 13 | 1090.68 | 18 | 15.00 | 1692 | 457 | 2.83 / 81.68 | 2 | 26 |
5 | 13 | 415.24 | 18 | 15.17 | 854 | 233 | 3.06 / 81.92 | 2 | 28 |
6 | 13 | 37.84 | 18 | 15.27 | 360 | 99 | 3.16 / 82.02 | 3 | 25 |
7 | 8 | 0.00 | 165 | 15.24 | 287 | 722 | 3.88 / 82.74 | 4 | 103 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 30 | 15.22 | 454 | 207 | 0.21 / 75.28 | 2 | 9 |
2 | 7 | 2006.20 | 38 | 14.91 | 2753 | 1560 | 1.77 / 76.84 | 2 | 19 |
3 | 13 | 1472.88 | 18 | 14.96 | 2147 | 578 | 2.35 / 77.42 | 2 | 24 |
4 | 13 | 982.40 | 18 | 15.03 | 1554 | 420 | 2.77 / 77.84 | 2 | 27 |
5 | 13 | 326.64 | 18 | 15.20 | 733 | 201 | 2.97 / 78.04 | 2 | 27 |
6 | 13 | 53.60 | 18 | 15.26 | 383 | 105 | 3.07 / 78.15 | 3 | 26 |
7 | 8 | 0.08 | 165 | 15.24 | 280 | 704 | 3.78 / 78.85 | 3 | 160 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 30 | 15.22 | 425 | 194 | 0.19 / 71.50 | 2 | 9 |
2 | 7 | 2003.92 | 38 | 14.92 | 2737 | 1552 | 1.75 / 73.06 | 2 | 19 |
3 | 13 | 1428.68 | 18 | 14.98 | 2093 | 564 | 2.31 / 73.62 | 2 | 24 |
4 | 13 | 906.88 | 18 | 15.06 | 1465 | 397 | 2.71 / 74.02 | 2 | 27 |
5 | 13 | 316.96 | 18 | 15.20 | 728 | 199 | 2.91 / 74.22 | 2 | 27 |
6 | 13 | 43.20 | 18 | 15.27 | 377 | 104 | 3.01 / 74.32 | 3 | 26 |
7 | 8 | 0.16 | 165 | 15.24 | 301 | 757 | 3.77 / 75.08 | 4 | 140 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 30 | 15.22 | 456 | 208 | 0.21 / 67.64 | 2 | 10 |
2 | 7 | 2004.68 | 38 | 14.91 | 2747 | 1556 | 1.76 / 69.20 | 2 | 19 |
3 | 13 | 1575.52 | 18 | 14.94 | 2271 | 611 | 2.38 / 69.81 | 2 | 22 |
4 | 13 | 965.20 | 18 | 15.04 | 1547 | 419 | 2.79 / 70.23 | 2 | 27 |
5 | 13 | 369.32 | 18 | 15.18 | 800 | 219 | 3.01 / 70.45 | 2 | 28 |
6 | 13 | 78.24 | 18 | 15.25 | 422 | 116 | 3.13 / 70.56 | 3 | 27 |
7 | 8 | 0.00 | 165 | 15.24 | 298 | 749 | 3.88 / 71.31 | 4 | 246 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 30 | 15.23 | 446 | 204 | 0.20 / 63.76 | 2 | 9 |
2 | 7 | 2001.96 | 38 | 14.92 | 2749 | 1559 | 1.76 / 65.32 | 2 | 21 |
3 | 13 | 1429.20 | 18 | 14.99 | 2099 | 566 | 2.33 / 65.89 | 2 | 25 |
4 | 13 | 993.52 | 18 | 15.04 | 1580 | 428 | 2.76 / 66.31 | 2 | 28 |
5 | 13 | 422.96 | 18 | 15.17 | 880 | 240 | 3.00 / 66.55 | 3 | 29 |
6 | 13 | 35.84 | 18 | 15.27 | 378 | 104 | 3.10 / 66.66 | 3 | 26 |
7 | 8 | 0.04 | 165 | 15.24 | 308 | 774 | 3.88 / 67.43 | 4 | 246 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 30 | 15.22 | 452 | 206 | 0.21 / 59.96 | 2 | 6 |
2 | 7 | 2005.08 | 38 | 14.93 | 2737 | 1553 | 1.76 / 61.51 | 2 | 20 |
3 | 13 | 1472.04 | 18 | 14.97 | 2160 | 582 | 2.34 / 62.09 | 2 | 24 |
4 | 13 | 890.60 | 18 | 15.07 | 1452 | 394 | 2.74 / 62.49 | 2 | 28 |
5 | 13 | 347.92 | 18 | 15.20 | 772 | 211 | 2.95 / 62.70 | 2 | 27 |
6 | 13 | 35.24 | 18 | 15.29 | 358 | 99 | 3.04 / 62.79 | 3 | 23 |
7 | 8 | 0.12 | 165 | 15.25 | 303 | 762 | 3.81 / 63.56 | 4 | 181 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 30 | 15.23 | 462 | 211 | 0.21 / 56.03 | 2 | 10 |
2 | 7 | 2002.96 | 38 | 14.92 | 2747 | 1557 | 1.77 / 57.58 | 2 | 19 |
3 | 13 | 1465.16 | 18 | 14.97 | 2152 | 580 | 2.35 / 58.16 | 2 | 23 |
4 | 13 | 971.88 | 18 | 15.05 | 1561 | 423 | 2.77 / 58.59 | 2 | 26 |
5 | 13 | 457.72 | 18 | 15.16 | 923 | 252 | 3.02 / 58.84 | 2 | 27 |
6 | 13 | 46.64 | 18 | 15.27 | 395 | 109 | 3.13 / 58.95 | 2 | 27 |
7 | 8 | 0.00 | 165 | 15.23 | 320 | 804 | 3.94 / 59.75 | 3 | 56 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 30 | 15.23 | 450 | 206 | 0.21 / 52.12 | 2 | 7 |
2 | 7 | 2002.24 | 39 | 14.94 | 2736 | 1594 | 1.80 / 53.72 | 2 | 20 |
3 | 13 | 1458.00 | 18 | 14.97 | 2120 | 571 | 2.37 / 54.29 | 2 | 22 |
4 | 13 | 873.16 | 18 | 15.09 | 1436 | 390 | 2.76 / 54.68 | 2 | 25 |
5 | 13 | 398.40 | 18 | 15.19 | 843 | 230 | 2.99 / 54.91 | 2 | 25 |
6 | 13 | 48.40 | 18 | 15.27 | 394 | 108 | 3.10 / 55.02 | 2 | 25 |
7 | 8 | 0.04 | 165 | 15.25 | 316 | 795 | 3.89 / 55.81 | 3 | 47 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 30 | 15.22 | 465 | 212 | 0.21 / 48.30 | 2 | 7 |
2 | 7 | 2009.04 | 38 | 14.93 | 2746 | 1558 | 1.77 / 49.86 | 2 | 19 |
3 | 13 | 1520.80 | 18 | 14.99 | 2193 | 592 | 2.36 / 50.45 | 2 | 21 |
4 | 13 | 822.24 | 18 | 15.09 | 1371 | 372 | 2.73 / 50.82 | 2 | 25 |
5 | 13 | 349.32 | 18 | 15.20 | 786 | 215 | 2.95 / 51.04 | 2 | 24 |
6 | 13 | 36.40 | 18 | 15.29 | 373 | 103 | 3.05 / 51.14 | 2 | 23 |
7 | 8 | 0.12 | 165 | 15.25 | 309 | 778 | 3.83 / 51.92 | 2 | 37 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 30 | 15.23 | 472 | 216 | 0.22 / 44.45 | 2 | 7 |
2 | 7 | 2004.60 | 38 | 14.94 | 2738 | 1554 | 1.77 / 46.00 | 2 | 18 |
3 | 13 | 1510.68 | 18 | 15.00 | 2194 | 592 | 2.36 / 46.60 | 2 | 21 |
4 | 13 | 914.36 | 18 | 15.09 | 1487 | 404 | 2.77 / 47.00 | 2 | 24 |
5 | 13 | 324.68 | 18 | 15.23 | 749 | 205 | 2.97 / 47.21 | 2 | 23 |
6 | 13 | 44.04 | 18 | 15.30 | 383 | 105 | 3.08 / 47.31 | 2 | 22 |
7 | 8 | 0.04 | 165 | 15.26 | 309 | 778 | 3.86 / 48.09 | 2 | 34 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 29 | 15.25 | 447 | 198 | 0.20 / 40.61 | 2 | 6 |
2 | 7 | 2006.44 | 38 | 14.95 | 2737 | 1555 | 1.75 / 42.17 | 2 | 18 |
3 | 13 | 1471.92 | 18 | 15.00 | 2148 | 580 | 2.33 / 42.75 | 2 | 20 |
4 | 13 | 878.88 | 18 | 15.11 | 1431 | 389 | 2.72 / 43.14 | 2 | 23 |
5 | 13 | 344.48 | 18 | 15.22 | 775 | 212 | 2.93 / 43.35 | 2 | 22 |
6 | 13 | 32.04 | 18 | 15.30 | 366 | 101 | 3.03 / 43.45 | 2 | 19 |
7 | 8 | 0.12 | 165 | 15.26 | 311 | 783 | 3.82 / 44.23 | 2 | 29 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 29 | 15.26 | 462 | 204 | 0.20 / 36.75 | 2 | 7 |
2 | 7 | 2007.00 | 38 | 14.95 | 2750 | 1562 | 1.77 / 38.32 | 2 | 17 |
3 | 13 | 1482.40 | 18 | 15.00 | 2156 | 582 | 2.35 / 38.90 | 2 | 21 |
4 | 13 | 941.40 | 18 | 15.09 | 1507 | 409 | 2.76 / 39.31 | 2 | 22 |
5 | 13 | 347.16 | 18 | 15.23 | 774 | 212 | 2.97 / 39.52 | 2 | 22 |
6 | 13 | 52.24 | 18 | 15.30 | 400 | 110 | 3.08 / 39.63 | 2 | 21 |
7 | 8 | 0.08 | 165 | 15.27 | 312 | 786 | 3.87 / 40.42 | 2 | 26 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 29 | 15.25 | 452 | 200 | 0.20 / 32.36 | 2 | 7 |
2 | 3 | 1017.56 | 1 | 15.29 | 1700 | 26 | 0.23 / 32.39 | 2 | 16 |
3 | 7 | 2005.44 | 74 | 14.83 | 2729 | 2995 | 3.22 / 35.39 | 2 | 18 |
4 | 13 | 475.64 | 18 | 15.20 | 923 | 253 | 3.47 / 35.64 | 2 | 21 |
5 | 13 | 99.92 | 18 | 15.30 | 463 | 128 | 3.60 / 35.77 | 2 | 19 |
6 | 8 | 0.28 | 165 | 15.29 | 311 | 785 | 4.39 / 36.55 | 2 | 25 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 29 | 15.26 | 456 | 202 | 0.20 / 28.02 | 2 | 8 |
2 | 7 | 2004.64 | 74 | 14.83 | 2740 | 3007 | 3.21 / 31.03 | 2 | 17 |
3 | 13 | 390.28 | 18 | 15.22 | 836 | 229 | 3.44 / 31.26 | 2 | 22 |
4 | 13 | 32.16 | 18 | 15.31 | 378 | 104 | 3.54 / 31.36 | 2 | 16 |
5 | 8 | 0.20 | 165 | 15.28 | 319 | 804 | 4.35 / 32.16 | 2 | 27 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 28 | 15.25 | 469 | 200 | 0.20 / 23.87 | 2 | 6 |
2 | 10 | 1004.08 | 2 | 15.26 | 1639 | 50 | 0.25 / 23.92 | 2 | 14 |
3 | 3 | 956.08 | -1 | 15.58 | 0 | 0 | 0.05 / 23.92 | 2 | 14 |
4 | 7 | 1802.52 | 74 | 14.91 | 2511 | 2770 | 3.02 / 26.69 | 2 | 17 |
5 | 13 | 366.36 | 18 | 15.24 | 810 | 222 | 3.24 / 26.92 | 2 | 20 |
6 | 13 | 16.84 | 18 | 15.33 | 346 | 95 | 3.34 / 27.01 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.29 | 320 | 807 | 4.15 / 27.82 | 2 | 25 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 28 | 15.25 | 471 | 201 | 0.20 / 19.74 | 2 | 5 |
2 | 3 | 1020.84 | 1 | 15.30 | 1670 | 26 | 0.23 / 19.76 | 2 | 16 |
3 | 7 | 1805.20 | 74 | 14.91 | 2512 | 2772 | 3.00 / 22.53 | 2 | 16 |
4 | 13 | 378.52 | 18 | 15.23 | 823 | 226 | 3.22 / 22.76 | 2 | 20 |
5 | 13 | 25.84 | 18 | 15.32 | 366 | 101 | 3.32 / 22.86 | 2 | 15 |
6 | 8 | 0.16 | 165 | 15.28 | 322 | 812 | 4.14 / 23.67 | 2 | 22 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 28 | 15.27 | 458 | 196 | 0.20 / 15.63 | 2 | 5 |
2 | 7 | 1776.20 | 74 | 14.93 | 2476 | 2736 | 2.93 / 18.37 | 2 | 15 |
3 | 13 | 496.80 | 18 | 15.21 | 955 | 261 | 3.19 / 18.63 | 2 | 20 |
4 | 13 | 36.88 | 18 | 15.31 | 375 | 103 | 3.30 / 18.73 | 2 | 17 |
5 | 8 | 0.08 | 165 | 15.29 | 318 | 802 | 4.10 / 19.54 | 2 | 24 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 28 | 15.27 | 447 | 191 | 0.19 / 11.91 | 2 | 6 |
2 | 7 | 1506.96 | 74 | 15.01 | 2171 | 2411 | 2.60 / 14.32 | 2 | 16 |
3 | 13 | 399.60 | 18 | 15.25 | 850 | 233 | 2.84 / 14.56 | 2 | 19 |
4 | 13 | 23.24 | 18 | 15.33 | 356 | 98 | 2.93 / 14.65 | 2 | 13 |
5 | 8 | 0.08 | 165 | 15.30 | 310 | 783 | 3.72 / 15.44 | 2 | 23 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 27 | 15.28 | 446 | 184 | 0.18 / 8.19 | 2 | 5 |
2 | 3 | 1031.04 | 1 | 15.30 | 1670 | 26 | 0.21 / 8.22 | 2 | 17 |
3 | 7 | 1516.24 | 74 | 15.01 | 2171 | 2411 | 2.62 / 10.63 | 2 | 14 |
4 | 13 | 353.96 | 18 | 15.26 | 784 | 215 | 2.84 / 10.84 | 2 | 19 |
5 | 13 | 22.80 | 18 | 15.34 | 348 | 96 | 2.93 / 10.94 | 2 | 17 |
6 | 8 | 0.08 | 165 | 15.30 | 309 | 780 | 3.71 / 11.72 | 2 | 25 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 32 | 15.32 | 449 | 220 | 0.22 / 4.59 | 2 | 8 |
2 | 3 | 839.60 | -3 | 15.61 | 0 | 0 | 0.00 / 4.59 | 2 | 8 |
3 | 3 | 959.32 | -1 | 15.63 | 0 | 0 | 0.00 / 4.59 | 2 | 8 |
4 | 7 | 1520.56 | 74 | 15.02 | 2177 | 2420 | 2.64 / 7.01 | 2 | 15 |
5 | 13 | 153.80 | 18 | 15.33 | 518 | 143 | 2.78 / 7.15 | 2 | 20 |
6 | 13 | 31.20 | 18 | 15.34 | 357 | 99 | 2.88 / 7.25 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.31 | 299 | 755 | 3.64 / 8.01 | 2 | 22 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 27 | 15.46 | 408 | 170 | 0.17 / 1.83 | 2 | 3 |
2 | 3 | 1018.32 | 1 | 15.34 | 1658 | 25 | 0.20 / 1.85 | 2 | 12 |
3 | 7 | 1002.44 | 74 | 15.20 | 1551 | 1745 | 1.94 / 3.60 | 2 | 18 |
4 | 8 | 0.12 | 165 | 15.36 | 305 | 773 | 2.71 / 4.37 | 2 | 23 |
Average= | 2.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 134.96 | 26 | 15.64 | 431 | 175 | 0.18 / 0.18 | 2 | 4 |
2 | 7 | 149.60 | 74 | 15.60 | 454 | 524 | 0.70 / 0.70 | 2 | 8 |
3 | 8 | 0.12 | 240 | 15.55 | 257 | 959 | 1.66 / 1.66 | 2 | 43 |
Average= | 1.66 (KJ/cycle) |