SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 33 | 15.09 | 432 | 215 | 0.22 / 290.89 | 2 | 4 |
2 | 7 | 2004.84 | 35 | 14.87 | 2894 | 1506 | 1.72 / 292.39 | 2 | 13 |
3 | 13 | 1793.76 | 20 | 14.85 | 2644 | 785 | 2.51 / 293.18 | 2 | 13 |
4 | 13 | 1272.04 | 20 | 14.90 | 1985 | 592 | 3.10 / 293.77 | 2 | 16 |
5 | 13 | 580.92 | 20 | 15.05 | 1096 | 330 | 3.43 / 294.10 | 2 | 18 |
6 | 13 | 49.72 | 20 | 15.19 | 374 | 114 | 3.54 / 294.21 | 2 | 12 |
7 | 13 | 22.08 | 20 | 15.18 | 336 | 102 | 3.64 / 294.31 | 2 | 20 |
8 | 8 | -0.04 | 165 | 15.13 | 300 | 749 | 4.39 / 295.06 | 2 | 30 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 33 | 15.10 | 447 | 223 | 0.22 / 286.47 | 2 | 4 |
2 | 7 | 2007.92 | 35 | 14.87 | 2897 | 1508 | 1.73 / 287.97 | 2 | 10 |
3 | 13 | 1957.64 | 20 | 14.82 | 2847 | 844 | 2.57 / 288.82 | 2 | 12 |
4 | 13 | 1174.44 | 20 | 14.93 | 1867 | 557 | 3.13 / 289.37 | 2 | 16 |
5 | 13 | 529.16 | 20 | 15.07 | 1032 | 311 | 3.44 / 289.69 | 2 | 18 |
6 | 13 | 92.88 | 20 | 15.17 | 434 | 132 | 3.57 / 289.82 | 2 | 17 |
7 | 13 | 30.12 | 20 | 15.18 | 351 | 107 | 3.68 / 289.92 | 2 | 17 |
8 | 8 | 0.04 | 165 | 15.13 | 299 | 746 | 4.43 / 290.67 | 2 | 30 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 33 | 15.12 | 444 | 222 | 0.22 / 281.92 | 2 | 4 |
2 | 7 | 2011.08 | 35 | 14.88 | 2908 | 1514 | 1.74 / 283.44 | 2 | 10 |
3 | 13 | 1961.52 | 20 | 14.82 | 2849 | 844 | 2.58 / 284.28 | 2 | 12 |
4 | 13 | 1285.64 | 20 | 14.91 | 2013 | 600 | 3.18 / 284.88 | 2 | 16 |
5 | 13 | 702.04 | 20 | 15.03 | 1261 | 379 | 3.56 / 285.26 | 2 | 18 |
6 | 13 | 26.12 | 20 | 15.19 | 352 | 107 | 3.67 / 285.37 | 2 | 17 |
7 | 13 | 21.08 | 20 | 15.18 | 345 | 105 | 3.77 / 285.47 | 2 | 12 |
8 | 8 | -0.08 | 165 | 15.13 | 308 | 769 | 4.54 / 286.24 | 2 | 24 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 33 | 15.12 | 441 | 220 | 0.22 / 277.92 | 3 | 3 |
2 | 7 | 1643.00 | 35 | 14.99 | 2448 | 1284 | 1.50 / 279.21 | 2 | 13 |
3 | 13 | 1597.04 | 20 | 14.94 | 2404 | 718 | 2.22 / 279.92 | 2 | 14 |
4 | 13 | 1148.04 | 20 | 14.99 | 1826 | 547 | 2.77 / 280.47 | 2 | 16 |
5 | 13 | 470.72 | 20 | 15.12 | 952 | 288 | 3.06 / 280.76 | 2 | 18 |
6 | 13 | 32.04 | 20 | 15.21 | 352 | 107 | 3.17 / 280.87 | 2 | 18 |
7 | 13 | 20.20 | 20 | 15.20 | 334 | 102 | 3.27 / 280.97 | 2 | 15 |
8 | 8 | -0.08 | 165 | 15.15 | 294 | 735 | 4.00 / 281.70 | 2 | 20 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 33 | 15.11 | 434 | 216 | 0.22 / 273.62 | 2 | 3 |
2 | 7 | 1738.44 | 35 | 14.96 | 2574 | 1348 | 1.56 / 274.97 | 2 | 13 |
3 | 13 | 1696.68 | 20 | 14.92 | 2541 | 758 | 2.32 / 275.73 | 2 | 14 |
4 | 13 | 1520.72 | 20 | 14.89 | 2306 | 687 | 3.01 / 276.41 | 2 | 16 |
5 | 13 | 561.76 | 20 | 15.10 | 1074 | 324 | 3.33 / 276.74 | 2 | 19 |
6 | 13 | 42.36 | 20 | 15.22 | 372 | 113 | 3.45 / 276.85 | 2 | 19 |
7 | 13 | 28.12 | 20 | 15.22 | 348 | 106 | 3.55 / 276.96 | 2 | 16 |
8 | 8 | 0.04 | 165 | 15.16 | 297 | 743 | 4.30 / 277.70 | 2 | 22 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 33 | 15.13 | 426 | 213 | 0.21 / 269.32 | 2 | 4 |
2 | 7 | 1882.88 | 35 | 14.91 | 2753 | 1437 | 1.65 / 270.75 | 2 | 13 |
3 | 13 | 1838.12 | 20 | 14.87 | 2714 | 807 | 2.46 / 271.56 | 2 | 13 |
4 | 13 | 1189.48 | 20 | 14.96 | 1887 | 565 | 3.02 / 272.12 | 2 | 17 |
5 | 13 | 538.28 | 20 | 15.10 | 1039 | 314 | 3.33 / 272.44 | 2 | 19 |
6 | 13 | 51.00 | 20 | 15.21 | 381 | 116 | 3.45 / 272.55 | 2 | 19 |
7 | 13 | 27.52 | 20 | 15.21 | 347 | 106 | 3.56 / 272.66 | 2 | 18 |
8 | 8 | -0.16 | 165 | 15.16 | 298 | 745 | 4.30 / 273.41 | 2 | 24 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 33 | 15.12 | 422 | 211 | 0.21 / 264.96 | 2 | 5 |
2 | 7 | 1949.80 | 35 | 14.90 | 2844 | 1483 | 1.69 / 266.45 | 2 | 12 |
3 | 13 | 1795.44 | 20 | 14.87 | 2655 | 790 | 2.48 / 267.24 | 2 | 14 |
4 | 13 | 1225.28 | 20 | 14.94 | 1940 | 580 | 3.06 / 267.82 | 2 | 17 |
5 | 13 | 580.20 | 20 | 15.09 | 1098 | 331 | 3.39 / 268.15 | 2 | 19 |
6 | 13 | 40.68 | 20 | 15.20 | 366 | 111 | 3.51 / 268.26 | 2 | 9 |
7 | 13 | 28.12 | 20 | 15.20 | 346 | 105 | 3.61 / 268.36 | 2 | 18 |
8 | 8 | 0.08 | 165 | 15.15 | 296 | 740 | 4.35 / 269.10 | 2 | 18 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 33 | 15.13 | 420 | 210 | 0.21 / 260.56 | 2 | 4 |
2 | 7 | 2012.04 | 35 | 14.89 | 2915 | 1519 | 1.73 / 262.08 | 2 | 10 |
3 | 13 | 1803.40 | 20 | 14.86 | 2663 | 791 | 2.52 / 262.87 | 2 | 13 |
4 | 13 | 1177.00 | 20 | 14.96 | 1872 | 560 | 3.08 / 263.43 | 2 | 16 |
5 | 13 | 563.40 | 20 | 15.09 | 1075 | 324 | 3.40 / 263.76 | 2 | 19 |
6 | 13 | 84.88 | 20 | 15.20 | 434 | 132 | 3.54 / 263.89 | 2 | 21 |
7 | 13 | 35.32 | 20 | 15.21 | 361 | 110 | 3.65 / 264.00 | 2 | 18 |
8 | 8 | 0.08 | 165 | 15.16 | 302 | 755 | 4.40 / 264.75 | 2 | 23 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 33 | 15.13 | 447 | 223 | 0.22 / 256.12 | 2 | 4 |
2 | 7 | 2016.00 | 35 | 14.90 | 2918 | 1522 | 1.74 / 257.64 | 2 | 10 |
3 | 13 | 1810.92 | 20 | 14.86 | 2669 | 793 | 2.54 / 258.44 | 2 | 13 |
4 | 13 | 1216.68 | 20 | 14.95 | 1924 | 575 | 3.11 / 259.01 | 2 | 16 |
5 | 13 | 678.88 | 20 | 15.06 | 1227 | 370 | 3.48 / 259.38 | 2 | 19 |
6 | 13 | 34.08 | 20 | 15.21 | 359 | 109 | 3.59 / 259.49 | 2 | 22 |
7 | 13 | 24.64 | 20 | 15.20 | 347 | 105 | 3.70 / 259.60 | 2 | 12 |
8 | 8 | 0.12 | 165 | 15.16 | 302 | 755 | 4.45 / 260.35 | 2 | 17 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 33 | 15.15 | 450 | 225 | 0.22 / 251.75 | 3 | 3 |
2 | 7 | 2005.52 | 35 | 14.89 | 2893 | 1508 | 1.73 / 253.26 | 2 | 11 |
3 | 13 | 1798.48 | 20 | 14.88 | 2656 | 790 | 2.52 / 254.05 | 2 | 14 |
4 | 13 | 1123.64 | 20 | 14.98 | 1804 | 540 | 3.06 / 254.59 | 2 | 17 |
5 | 13 | 649.32 | 20 | 15.08 | 1191 | 359 | 3.42 / 254.95 | 2 | 19 |
6 | 13 | 30.96 | 20 | 15.22 | 354 | 108 | 3.53 / 255.05 | 2 | 19 |
7 | 13 | 22.80 | 20 | 15.21 | 338 | 103 | 3.63 / 255.16 | 2 | 20 |
8 | 8 | 0.00 | 165 | 15.17 | 296 | 741 | 4.37 / 255.90 | 2 | 21 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 33 | 15.15 | 455 | 227 | 0.23 / 247.27 | 2 | 4 |
2 | 7 | 2005.80 | 35 | 14.91 | 2912 | 1520 | 1.75 / 248.79 | 2 | 11 |
3 | 13 | 1956.32 | 20 | 14.87 | 2857 | 850 | 2.60 / 249.64 | 2 | 13 |
4 | 13 | 1276.68 | 20 | 14.96 | 1998 | 598 | 3.19 / 250.24 | 2 | 16 |
5 | 13 | 527.16 | 20 | 15.13 | 1026 | 310 | 3.51 / 250.55 | 2 | 18 |
6 | 13 | 35.08 | 20 | 15.23 | 362 | 110 | 3.62 / 250.66 | 2 | 14 |
7 | 13 | 26.20 | 20 | 15.22 | 347 | 106 | 3.72 / 250.76 | 2 | 12 |
8 | 8 | -0.08 | 165 | 15.18 | 303 | 759 | 4.48 / 251.52 | 2 | 26 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 33 | 15.16 | 439 | 220 | 0.22 / 242.87 | 2 | 5 |
2 | 7 | 2014.04 | 35 | 14.91 | 2914 | 1521 | 1.74 / 244.39 | 2 | 13 |
3 | 13 | 1751.84 | 20 | 14.88 | 2597 | 773 | 2.51 / 245.16 | 2 | 16 |
4 | 13 | 1235.40 | 20 | 14.95 | 1955 | 585 | 3.10 / 245.74 | 2 | 17 |
5 | 13 | 536.28 | 20 | 15.11 | 1042 | 315 | 3.41 / 246.06 | 2 | 20 |
6 | 13 | 54.52 | 20 | 15.22 | 386 | 117 | 3.53 / 246.18 | 2 | 20 |
7 | 13 | 27.12 | 20 | 15.21 | 351 | 107 | 3.64 / 246.28 | 2 | 18 |
8 | 8 | 0.08 | 165 | 15.18 | 304 | 761 | 4.40 / 247.04 | 2 | 28 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 33 | 15.17 | 433 | 217 | 0.22 / 238.48 | 2 | 3 |
2 | 7 | 2015.44 | 35 | 14.91 | 2915 | 1521 | 1.74 / 240.00 | 2 | 11 |
3 | 13 | 1811.80 | 20 | 14.89 | 2676 | 797 | 2.53 / 240.80 | 2 | 13 |
4 | 13 | 1193.24 | 20 | 14.97 | 1893 | 567 | 3.10 / 241.36 | 2 | 16 |
5 | 13 | 557.40 | 20 | 15.11 | 1075 | 325 | 3.43 / 241.69 | 2 | 19 |
6 | 13 | 29.96 | 20 | 15.23 | 353 | 108 | 3.53 / 241.80 | 2 | 10 |
7 | 13 | 14.44 | 20 | 15.23 | 326 | 99 | 3.63 / 241.90 | 2 | 21 |
8 | 8 | 0.04 | 165 | 15.18 | 299 | 749 | 4.38 / 242.65 | 2 | 27 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 33 | 15.15 | 457 | 228 | 0.23 / 234.29 | 3 | 8 |
2 | 7 | 2013.20 | 35 | 14.91 | 2908 | 1518 | 1.75 / 235.81 | 2 | 13 |
3 | 13 | 1686.68 | 20 | 14.91 | 2520 | 751 | 2.50 / 236.56 | 2 | 12 |
4 | 13 | 1158.16 | 20 | 14.97 | 1851 | 554 | 3.05 / 237.11 | 2 | 16 |
5 | 13 | 468.24 | 20 | 15.14 | 949 | 287 | 3.34 / 237.40 | 2 | 19 |
6 | 13 | 25.68 | 20 | 15.24 | 344 | 105 | 3.44 / 237.51 | 2 | 22 |
7 | 8 | 0.04 | 165 | 15.19 | 302 | 757 | 4.20 / 238.26 | 2 | 22 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 33 | 15.16 | 422 | 211 | 0.21 / 229.84 | 3 | 4 |
2 | 7 | 2013.12 | 35 | 14.91 | 2915 | 1521 | 1.73 / 231.36 | 2 | 11 |
3 | 13 | 1749.40 | 20 | 14.90 | 2599 | 775 | 2.51 / 232.14 | 2 | 13 |
4 | 13 | 1280.92 | 20 | 14.97 | 1998 | 598 | 3.11 / 232.73 | 2 | 16 |
5 | 13 | 676.40 | 20 | 15.09 | 1222 | 369 | 3.47 / 233.10 | 2 | 18 |
6 | 13 | 36.68 | 20 | 15.24 | 361 | 110 | 3.58 / 233.21 | 2 | 17 |
7 | 13 | 22.44 | 20 | 15.23 | 336 | 102 | 3.69 / 233.32 | 2 | 18 |
8 | 8 | -0.04 | 165 | 15.18 | 298 | 746 | 4.43 / 234.06 | 2 | 26 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 33 | 15.17 | 457 | 229 | 0.23 / 225.49 | 2 | 5 |
2 | 7 | 2014.40 | 35 | 14.91 | 2908 | 1518 | 1.75 / 227.00 | 2 | 10 |
3 | 13 | 1810.92 | 20 | 14.90 | 2669 | 795 | 2.54 / 227.80 | 2 | 13 |
4 | 13 | 1173.88 | 20 | 14.99 | 1862 | 558 | 3.10 / 228.36 | 2 | 15 |
5 | 13 | 534.28 | 20 | 15.13 | 1035 | 313 | 3.41 / 228.67 | 2 | 18 |
6 | 13 | 54.12 | 20 | 15.24 | 383 | 117 | 3.53 / 228.79 | 2 | 13 |
7 | 13 | 26.52 | 20 | 15.23 | 342 | 104 | 3.63 / 228.89 | 2 | 15 |
8 | 8 | 0.04 | 165 | 15.19 | 295 | 739 | 4.37 / 229.63 | 2 | 20 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 33 | 15.16 | 448 | 224 | 0.22 / 221.23 | 2 | 4 |
2 | 7 | 2010.36 | 35 | 14.92 | 2906 | 1518 | 1.74 / 222.75 | 2 | 11 |
3 | 13 | 1751.36 | 20 | 14.92 | 2593 | 774 | 2.52 / 223.52 | 2 | 14 |
4 | 13 | 1230.60 | 20 | 14.98 | 1944 | 582 | 3.10 / 224.10 | 2 | 16 |
5 | 13 | 482.80 | 20 | 15.15 | 965 | 292 | 3.39 / 224.40 | 2 | 19 |
6 | 13 | 35.64 | 20 | 15.25 | 356 | 109 | 3.50 / 224.50 | 2 | 18 |
7 | 8 | 0.00 | 165 | 15.21 | 300 | 753 | 4.25 / 225.26 | 2 | 21 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 33 | 15.17 | 457 | 229 | 0.23 / 216.86 | 2 | 4 |
2 | 7 | 1970.84 | 35 | 14.92 | 2854 | 1490 | 1.72 / 218.35 | 2 | 11 |
3 | 13 | 1865.84 | 20 | 14.88 | 2736 | 814 | 2.53 / 219.17 | 2 | 13 |
4 | 13 | 1164.24 | 20 | 15.01 | 1855 | 557 | 3.09 / 219.72 | 2 | 17 |
5 | 13 | 492.24 | 20 | 15.16 | 983 | 298 | 3.39 / 220.02 | 2 | 18 |
6 | 13 | 74.04 | 20 | 15.23 | 415 | 126 | 3.51 / 220.15 | 2 | 18 |
7 | 13 | 20.40 | 20 | 15.24 | 337 | 103 | 3.62 / 220.25 | 2 | 14 |
8 | 8 | 0.04 | 165 | 15.19 | 301 | 754 | 4.37 / 221.00 | 2 | 25 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 33 | 15.16 | 464 | 232 | 0.23 / 212.56 | 2 | 4 |
2 | 7 | 1991.12 | 35 | 14.90 | 2881 | 1502 | 1.73 / 214.06 | 2 | 11 |
3 | 13 | 1834.60 | 20 | 14.88 | 2705 | 805 | 2.54 / 214.86 | 2 | 13 |
4 | 13 | 1242.08 | 20 | 14.98 | 1955 | 586 | 3.13 / 215.45 | 2 | 16 |
5 | 13 | 534.76 | 20 | 15.13 | 1034 | 313 | 3.44 / 215.76 | 2 | 19 |
6 | 13 | 35.88 | 20 | 15.25 | 359 | 109 | 3.55 / 215.87 | 2 | 17 |
7 | 8 | 0.16 | 165 | 15.21 | 303 | 760 | 4.31 / 216.63 | 2 | 24 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 33 | 15.18 | 461 | 231 | 0.23 / 207.98 | 2 | 6 |
2 | 7 | 2004.24 | 35 | 14.92 | 2902 | 1515 | 1.75 / 209.49 | 2 | 10 |
3 | 13 | 1900.48 | 20 | 14.89 | 2786 | 830 | 2.58 / 210.32 | 2 | 12 |
4 | 13 | 1335.24 | 20 | 14.96 | 2074 | 621 | 3.20 / 210.94 | 2 | 15 |
5 | 13 | 707.08 | 20 | 15.10 | 1269 | 383 | 3.58 / 211.33 | 2 | 18 |
6 | 13 | 323.44 | 20 | 15.18 | 759 | 230 | 3.81 / 211.56 | 2 | 19 |
7 | 8 | 0.12 | 165 | 15.20 | 306 | 767 | 4.58 / 212.32 | 2 | 23 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 33 | 15.18 | 459 | 230 | 0.23 / 203.60 | 2 | 6 |
2 | 7 | 2005.36 | 35 | 14.92 | 2900 | 1514 | 1.74 / 205.12 | 2 | 10 |
3 | 13 | 1848.76 | 20 | 14.89 | 2706 | 806 | 2.55 / 205.92 | 2 | 13 |
4 | 13 | 1200.76 | 20 | 14.99 | 1897 | 569 | 3.12 / 206.49 | 2 | 16 |
5 | 13 | 612.40 | 20 | 15.12 | 1137 | 344 | 3.46 / 206.83 | 2 | 19 |
6 | 13 | 61.72 | 20 | 15.25 | 406 | 124 | 3.59 / 206.96 | 2 | 17 |
7 | 8 | 0.16 | 165 | 15.22 | 314 | 789 | 4.38 / 207.75 | 2 | 21 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 33 | 15.17 | 471 | 236 | 0.24 / 199.29 | 2 | 5 |
2 | 7 | 2004.72 | 35 | 14.94 | 2895 | 1514 | 1.75 / 200.81 | 2 | 12 |
3 | 13 | 1800.24 | 20 | 14.94 | 2667 | 797 | 2.55 / 201.60 | 2 | 12 |
4 | 13 | 1224.80 | 20 | 15.00 | 1927 | 578 | 3.12 / 202.18 | 2 | 16 |
5 | 13 | 537.68 | 20 | 15.15 | 1042 | 316 | 3.44 / 202.50 | 2 | 18 |
6 | 13 | 29.08 | 20 | 15.27 | 351 | 107 | 3.55 / 202.61 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.23 | 305 | 766 | 4.31 / 203.37 | 2 | 23 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.00 | 33 | 15.19 | 473 | 237 | 0.24 / 195.03 | 2 | 6 |
2 | 7 | 2004.28 | 35 | 14.94 | 2895 | 1514 | 1.75 / 196.54 | 2 | 12 |
3 | 13 | 1737.48 | 20 | 14.93 | 2566 | 766 | 2.52 / 197.31 | 2 | 12 |
4 | 13 | 1114.00 | 20 | 15.03 | 1794 | 539 | 3.06 / 197.84 | 2 | 16 |
5 | 13 | 545.52 | 20 | 15.16 | 1059 | 321 | 3.38 / 198.17 | 2 | 18 |
6 | 13 | 34.36 | 20 | 15.26 | 365 | 111 | 3.49 / 198.28 | 2 | 17 |
7 | 8 | 0.16 | 165 | 15.22 | 311 | 781 | 4.27 / 199.06 | 2 | 23 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 33 | 15.19 | 459 | 230 | 0.23 / 190.66 | 2 | 5 |
2 | 7 | 2004.12 | 35 | 14.94 | 2904 | 1519 | 1.75 / 192.17 | 2 | 11 |
3 | 13 | 1798.60 | 20 | 14.93 | 2662 | 795 | 2.54 / 192.97 | 2 | 14 |
4 | 13 | 1265.04 | 20 | 15.01 | 1983 | 595 | 3.14 / 193.56 | 2 | 16 |
5 | 13 | 563.08 | 20 | 15.15 | 1080 | 327 | 3.47 / 193.89 | 2 | 18 |
6 | 13 | 80.64 | 20 | 15.25 | 428 | 131 | 3.60 / 194.02 | 2 | 17 |
7 | 8 | -0.08 | 165 | 15.22 | 305 | 766 | 4.36 / 194.79 | 2 | 23 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 32 | 15.18 | 447 | 217 | 0.22 / 186.65 | 2 | 4 |
2 | 7 | 2013.24 | 39 | 14.91 | 2904 | 1689 | 1.91 / 188.33 | 2 | 13 |
3 | 13 | 1440.88 | 20 | 14.99 | 2213 | 663 | 2.57 / 189.00 | 2 | 15 |
4 | 13 | 840.00 | 20 | 15.09 | 1446 | 436 | 3.01 / 189.43 | 2 | 18 |
5 | 13 | 318.28 | 20 | 15.21 | 747 | 227 | 3.23 / 189.66 | 2 | 18 |
6 | 8 | 0.20 | 165 | 15.23 | 304 | 764 | 4.00 / 190.43 | 2 | 19 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 32 | 15.18 | 451 | 219 | 0.22 / 182.62 | 3 | 5 |
2 | 7 | 2014.56 | 38 | 14.91 | 2906 | 1646 | 1.87 / 184.26 | 2 | 12 |
3 | 13 | 1519.88 | 20 | 14.95 | 2307 | 690 | 2.56 / 184.95 | 2 | 14 |
4 | 13 | 839.60 | 20 | 15.08 | 1437 | 433 | 2.99 / 185.39 | 2 | 17 |
5 | 13 | 205.72 | 20 | 15.23 | 596 | 182 | 3.17 / 185.57 | 2 | 17 |
6 | 13 | 18.92 | 20 | 15.26 | 334 | 102 | 3.27 / 185.67 | 2 | 17 |
7 | 8 | 0.16 | 165 | 15.21 | 303 | 760 | 4.03 / 186.43 | 2 | 24 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 32 | 15.20 | 456 | 222 | 0.22 / 178.58 | 2 | 5 |
2 | 10 | 1008.60 | 2 | 15.24 | 1691 | 52 | 0.27 / 178.63 | 2 | 8 |
3 | 3 | 949.48 | -2 | 15.52 | 0 | 0 | 0.05 / 178.63 | 2 | 8 |
4 | 7 | 2004.64 | 38 | 14.91 | 2892 | 1639 | 1.91 / 180.27 | 2 | 12 |
5 | 13 | 1474.56 | 20 | 14.97 | 2249 | 673 | 2.59 / 180.95 | 2 | 14 |
6 | 13 | 802.92 | 20 | 15.11 | 1396 | 422 | 3.01 / 181.37 | 2 | 17 |
7 | 13 | 159.48 | 20 | 15.24 | 531 | 162 | 3.17 / 181.53 | 2 | 16 |
8 | 13 | 12.04 | 20 | 15.27 | 328 | 100 | 3.27 / 181.63 | 2 | 14 |
9 | 8 | 0.00 | 165 | 15.23 | 305 | 766 | 4.04 / 182.40 | 2 | 24 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 32 | 15.19 | 462 | 225 | 0.22 / 174.60 | 2 | 4 |
2 | 7 | 2004.72 | 38 | 14.93 | 2888 | 1638 | 1.86 / 176.23 | 2 | 14 |
3 | 13 | 1429.00 | 20 | 14.99 | 2192 | 657 | 2.52 / 176.89 | 2 | 15 |
4 | 13 | 809.68 | 20 | 15.11 | 1401 | 423 | 2.94 / 177.32 | 2 | 17 |
5 | 13 | 195.28 | 20 | 15.26 | 591 | 180 | 3.12 / 177.50 | 2 | 17 |
6 | 13 | 20.56 | 20 | 15.28 | 340 | 104 | 3.23 / 177.60 | 2 | 17 |
7 | 8 | 0.20 | 165 | 15.23 | 303 | 761 | 3.99 / 178.36 | 2 | 26 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 32 | 15.20 | 459 | 223 | 0.22 / 170.63 | 2 | 6 |
2 | 7 | 2007.44 | 38 | 14.92 | 2893 | 1640 | 1.86 / 172.27 | 2 | 11 |
3 | 13 | 1379.48 | 20 | 15.00 | 2136 | 641 | 2.50 / 172.91 | 2 | 14 |
4 | 13 | 766.92 | 20 | 15.12 | 1343 | 406 | 2.91 / 173.32 | 2 | 17 |
5 | 13 | 211.12 | 20 | 15.24 | 604 | 184 | 3.09 / 173.50 | 2 | 17 |
6 | 13 | 17.76 | 20 | 15.27 | 340 | 104 | 3.20 / 173.61 | 2 | 17 |
7 | 8 | 0.04 | 165 | 15.22 | 305 | 766 | 3.96 / 174.37 | 2 | 22 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 32 | 15.19 | 456 | 222 | 0.22 / 166.54 | 3 | 3 |
2 | 7 | 2015.92 | 38 | 14.92 | 2913 | 1652 | 1.87 / 168.20 | 2 | 12 |
3 | 13 | 1481.68 | 20 | 14.99 | 2259 | 677 | 2.55 / 168.87 | 2 | 15 |
4 | 13 | 952.52 | 20 | 15.09 | 1585 | 478 | 3.03 / 169.35 | 2 | 17 |
5 | 13 | 215.28 | 20 | 15.26 | 611 | 186 | 3.22 / 169.54 | 2 | 17 |
6 | 13 | 17.24 | 20 | 15.28 | 341 | 104 | 3.32 / 169.64 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.24 | 304 | 764 | 4.08 / 170.41 | 2 | 21 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 32 | 15.19 | 452 | 220 | 0.22 / 162.45 | 2 | 5 |
2 | 7 | 2012.56 | 39 | 14.93 | 2910 | 1694 | 1.91 / 164.15 | 2 | 11 |
3 | 13 | 1479.04 | 20 | 15.00 | 2253 | 676 | 2.59 / 164.82 | 2 | 14 |
4 | 13 | 820.92 | 20 | 15.11 | 1422 | 430 | 3.02 / 165.25 | 2 | 18 |
5 | 13 | 169.64 | 20 | 15.26 | 550 | 168 | 3.19 / 165.42 | 2 | 18 |
6 | 13 | 20.08 | 20 | 15.28 | 343 | 105 | 3.29 / 165.52 | 2 | 11 |
7 | 8 | 18.80 | 165 | 15.23 | 318 | 799 | 4.09 / 166.32 | 2 | 23 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 32 | 15.19 | 438 | 213 | 0.21 / 158.37 | 3 | 4 |
2 | 7 | 2009.08 | 38 | 14.93 | 2906 | 1649 | 1.86 / 160.02 | 2 | 13 |
3 | 13 | 1525.28 | 20 | 14.99 | 2316 | 694 | 2.56 / 160.72 | 2 | 16 |
4 | 13 | 808.48 | 20 | 15.13 | 1401 | 424 | 2.98 / 161.14 | 2 | 18 |
5 | 13 | 210.88 | 20 | 15.26 | 604 | 184 | 3.16 / 161.32 | 2 | 18 |
6 | 13 | 25.48 | 20 | 15.29 | 352 | 108 | 3.27 / 161.43 | 2 | 13 |
7 | 8 | 16.24 | 165 | 15.23 | 318 | 799 | 4.07 / 162.23 | 2 | 16 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 32 | 15.20 | 441 | 215 | 0.21 / 154.24 | 2 | 3 |
2 | 3 | 982.88 | -1 | 15.55 | 0 | 0 | 0.00 / 154.24 | 2 | 3 |
3 | 7 | 2011.32 | 39 | 14.93 | 2903 | 1690 | 1.90 / 155.93 | 2 | 12 |
4 | 13 | 1386.72 | 20 | 15.01 | 2148 | 645 | 2.55 / 156.58 | 2 | 16 |
5 | 13 | 849.68 | 20 | 15.10 | 1462 | 442 | 2.99 / 157.02 | 2 | 18 |
6 | 13 | 191.36 | 20 | 15.26 | 576 | 176 | 3.17 / 157.20 | 2 | 16 |
7 | 13 | 38.24 | 20 | 15.28 | 364 | 111 | 3.28 / 157.31 | 2 | 16 |
8 | 13 | 22.36 | 20 | 15.26 | 345 | 105 | 3.38 / 157.41 | 2 | 10 |
9 | 8 | 0.16 | 165 | 15.22 | 298 | 748 | 4.13 / 158.16 | 2 | 23 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 32 | 15.20 | 453 | 220 | 0.22 / 150.16 | 3 | 4 |
2 | 7 | 2014.84 | 38 | 14.93 | 2911 | 1652 | 1.87 / 151.81 | 2 | 11 |
3 | 13 | 1441.64 | 20 | 15.02 | 2215 | 665 | 2.54 / 152.48 | 2 | 15 |
4 | 13 | 798.76 | 20 | 15.13 | 1388 | 420 | 2.96 / 152.90 | 2 | 18 |
5 | 13 | 201.08 | 20 | 15.25 | 589 | 180 | 3.14 / 153.07 | 2 | 17 |
6 | 13 | 25.52 | 20 | 15.28 | 345 | 105 | 3.24 / 153.18 | 2 | 17 |
7 | 13 | 25.20 | 20 | 15.27 | 343 | 105 | 3.35 / 153.29 | 2 | 13 |
8 | 8 | -0.04 | 165 | 15.23 | 296 | 744 | 4.09 / 154.03 | 2 | 22 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 32 | 15.20 | 457 | 222 | 0.22 / 145.99 | 3 | 3 |
2 | 7 | 2006.96 | 38 | 14.94 | 2901 | 1647 | 1.87 / 147.63 | 2 | 11 |
3 | 13 | 1484.64 | 20 | 15.00 | 2257 | 677 | 2.55 / 148.31 | 2 | 15 |
4 | 13 | 835.88 | 20 | 15.11 | 1434 | 433 | 2.98 / 148.75 | 2 | 18 |
5 | 13 | 318.88 | 20 | 15.23 | 749 | 228 | 3.21 / 148.97 | 2 | 18 |
6 | 13 | 28.72 | 20 | 15.29 | 350 | 107 | 3.31 / 149.08 | 2 | 14 |
7 | 13 | 16.04 | 20 | 15.28 | 331 | 101 | 3.42 / 149.18 | 2 | 16 |
8 | 8 | 0.04 | 165 | 15.23 | 301 | 756 | 4.17 / 149.94 | 2 | 25 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 32 | 15.21 | 428 | 208 | 0.21 / 141.89 | 3 | 3 |
2 | 7 | 2006.16 | 38 | 14.94 | 2901 | 1647 | 1.86 / 143.54 | 2 | 10 |
3 | 13 | 1450.04 | 20 | 15.03 | 2214 | 666 | 2.52 / 144.21 | 2 | 14 |
4 | 13 | 764.76 | 20 | 15.13 | 1338 | 405 | 2.93 / 144.61 | 2 | 17 |
5 | 13 | 207.08 | 20 | 15.26 | 596 | 182 | 3.11 / 144.79 | 2 | 16 |
6 | 13 | 24.64 | 20 | 15.29 | 349 | 107 | 3.21 / 144.90 | 2 | 13 |
7 | 13 | 11.24 | 20 | 15.28 | 331 | 101 | 3.32 / 145.00 | 2 | 17 |
8 | 8 | -0.16 | 165 | 15.23 | 304 | 764 | 4.08 / 145.77 | 2 | 24 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 32 | 15.19 | 432 | 210 | 0.21 / 137.94 | 3 | 4 |
2 | 7 | 2006.68 | 38 | 14.94 | 2895 | 1644 | 1.85 / 139.58 | 2 | 12 |
3 | 13 | 1378.04 | 20 | 15.03 | 2129 | 640 | 2.49 / 140.22 | 2 | 16 |
4 | 13 | 763.36 | 20 | 15.14 | 1345 | 407 | 2.90 / 140.63 | 2 | 18 |
5 | 13 | 256.76 | 20 | 15.25 | 663 | 202 | 3.10 / 140.83 | 2 | 17 |
6 | 13 | 32.48 | 20 | 15.29 | 354 | 108 | 3.21 / 140.94 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.24 | 298 | 749 | 3.96 / 141.69 | 2 | 24 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 32 | 15.22 | 452 | 220 | 0.22 / 133.85 | 2 | 4 |
2 | 7 | 2010.24 | 39 | 14.93 | 2893 | 1685 | 1.90 / 135.53 | 2 | 12 |
3 | 13 | 1342.56 | 20 | 15.03 | 2087 | 627 | 2.53 / 136.16 | 2 | 16 |
4 | 13 | 775.40 | 20 | 15.13 | 1355 | 410 | 2.94 / 136.57 | 2 | 19 |
5 | 13 | 215.16 | 20 | 15.25 | 612 | 187 | 3.13 / 136.76 | 2 | 17 |
6 | 13 | 32.36 | 20 | 15.27 | 357 | 109 | 3.24 / 136.87 | 2 | 16 |
7 | 13 | 24.68 | 20 | 15.27 | 346 | 106 | 3.34 / 136.97 | 2 | 18 |
8 | 8 | -0.04 | 165 | 15.23 | 300 | 754 | 4.10 / 137.73 | 2 | 23 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 32 | 15.21 | 437 | 213 | 0.21 / 129.72 | 2 | 4 |
2 | 7 | 2011.04 | 38 | 14.94 | 2899 | 1646 | 1.86 / 131.36 | 2 | 12 |
3 | 13 | 1470.36 | 20 | 15.02 | 2250 | 676 | 2.53 / 132.04 | 2 | 16 |
4 | 13 | 827.28 | 20 | 15.13 | 1430 | 433 | 2.97 / 132.47 | 2 | 18 |
5 | 13 | 215.76 | 20 | 15.26 | 613 | 187 | 3.15 / 132.66 | 2 | 17 |
6 | 13 | 35.68 | 20 | 15.29 | 360 | 110 | 3.26 / 132.77 | 2 | 13 |
7 | 13 | 15.88 | 20 | 15.28 | 333 | 102 | 3.37 / 132.87 | 2 | 14 |
8 | 8 | 0.00 | 165 | 15.23 | 302 | 759 | 4.12 / 133.63 | 2 | 24 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 32 | 15.22 | 432 | 210 | 0.21 / 125.63 | 2 | 3 |
2 | 7 | 2005.00 | 38 | 14.96 | 2901 | 1649 | 1.86 / 127.28 | 2 | 12 |
3 | 13 | 1399.44 | 20 | 15.04 | 2164 | 651 | 2.51 / 127.93 | 2 | 16 |
4 | 13 | 776.28 | 20 | 15.14 | 1362 | 412 | 2.92 / 128.34 | 2 | 18 |
5 | 13 | 215.48 | 20 | 15.27 | 619 | 189 | 3.11 / 128.53 | 2 | 17 |
6 | 13 | 35.96 | 20 | 15.30 | 356 | 109 | 3.22 / 128.64 | 2 | 13 |
7 | 13 | 18.20 | 20 | 15.29 | 338 | 103 | 3.32 / 128.74 | 2 | 17 |
8 | 8 | -0.08 | 165 | 15.24 | 302 | 759 | 4.08 / 129.50 | 2 | 18 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 32 | 15.23 | 466 | 227 | 0.23 / 121.66 | 3 | 3 |
2 | 7 | 2008.20 | 38 | 14.96 | 2904 | 1651 | 1.88 / 123.31 | 2 | 10 |
3 | 13 | 1376.72 | 20 | 15.04 | 2136 | 643 | 2.52 / 123.95 | 2 | 14 |
4 | 13 | 793.24 | 20 | 15.15 | 1383 | 419 | 2.94 / 124.37 | 2 | 16 |
5 | 13 | 193.56 | 20 | 15.29 | 580 | 177 | 3.12 / 124.55 | 2 | 15 |
6 | 13 | 29.00 | 20 | 15.30 | 353 | 108 | 3.22 / 124.66 | 2 | 15 |
7 | 8 | 0.32 | 165 | 15.26 | 303 | 763 | 3.99 / 125.42 | 2 | 19 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 32 | 15.22 | 429 | 209 | 0.21 / 117.61 | 3 | 3 |
2 | 3 | 1017.40 | 1 | 15.30 | 1735 | 27 | 0.24 / 117.63 | 2 | 8 |
3 | 7 | 2008.40 | 38 | 14.96 | 2896 | 1646 | 1.88 / 119.28 | 2 | 10 |
4 | 13 | 1407.60 | 20 | 15.04 | 2170 | 653 | 2.53 / 119.93 | 2 | 14 |
5 | 13 | 850.80 | 20 | 15.14 | 1460 | 442 | 2.98 / 120.37 | 2 | 17 |
6 | 13 | 183.80 | 20 | 15.29 | 571 | 175 | 3.15 / 120.55 | 2 | 15 |
7 | 13 | 20.64 | 20 | 15.32 | 346 | 106 | 3.26 / 120.65 | 2 | 14 |
8 | 8 | -0.08 | 165 | 15.26 | 309 | 778 | 4.04 / 121.43 | 2 | 19 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 32 | 15.24 | 461 | 225 | 0.22 / 113.53 | 3 | 3 |
2 | 7 | 2005.48 | 38 | 14.96 | 2893 | 1645 | 1.87 / 115.17 | 2 | 8 |
3 | 13 | 1420.40 | 20 | 15.04 | 2187 | 658 | 2.53 / 115.83 | 2 | 12 |
4 | 13 | 811.88 | 20 | 15.16 | 1408 | 427 | 2.95 / 116.26 | 2 | 15 |
5 | 13 | 165.88 | 20 | 15.29 | 543 | 166 | 3.12 / 116.42 | 2 | 14 |
6 | 13 | 35.76 | 20 | 15.32 | 367 | 112 | 3.23 / 116.53 | 2 | 12 |
7 | 13 | 12.28 | 20 | 15.30 | 323 | 99 | 3.33 / 116.63 | 2 | 13 |
8 | 8 | 0.00 | 165 | 15.26 | 303 | 763 | 4.09 / 117.40 | 2 | 20 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 32 | 15.22 | 435 | 212 | 0.21 / 109.52 | 3 | 3 |
2 | 7 | 2009.24 | 38 | 14.97 | 2904 | 1652 | 1.86 / 111.17 | 2 | 11 |
3 | 13 | 1426.60 | 20 | 15.05 | 2195 | 661 | 2.52 / 111.83 | 2 | 12 |
4 | 13 | 795.24 | 20 | 15.16 | 1393 | 422 | 2.95 / 112.25 | 2 | 15 |
5 | 13 | 154.00 | 20 | 15.30 | 532 | 163 | 3.11 / 112.42 | 2 | 14 |
6 | 13 | 25.88 | 20 | 15.31 | 355 | 109 | 3.22 / 112.53 | 2 | 14 |
7 | 8 | 0.00 | 165 | 15.27 | 308 | 776 | 3.99 / 113.30 | 2 | 19 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 32 | 15.23 | 453 | 221 | 0.22 / 105.37 | 3 | 3 |
2 | 7 | 2012.28 | 38 | 14.96 | 2912 | 1655 | 1.88 / 107.02 | 2 | 8 |
3 | 13 | 1510.72 | 20 | 15.03 | 2299 | 691 | 2.57 / 107.71 | 2 | 12 |
4 | 13 | 835.36 | 20 | 15.14 | 1440 | 436 | 3.00 / 108.15 | 2 | 15 |
5 | 13 | 184.12 | 20 | 15.29 | 574 | 176 | 3.18 / 108.32 | 2 | 15 |
6 | 13 | 39.44 | 20 | 15.31 | 372 | 114 | 3.29 / 108.44 | 2 | 13 |
7 | 13 | 14.52 | 20 | 15.30 | 332 | 102 | 3.39 / 108.54 | 2 | 13 |
8 | 8 | -0.12 | 165 | 15.26 | 305 | 768 | 4.16 / 109.31 | 2 | 21 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 32 | 15.24 | 464 | 226 | 0.23 / 101.35 | 3 | 3 |
2 | 7 | 2014.24 | 39 | 14.96 | 2906 | 1695 | 1.92 / 103.04 | 2 | 11 |
3 | 13 | 1349.36 | 20 | 15.06 | 2100 | 633 | 2.55 / 103.68 | 2 | 12 |
4 | 13 | 743.68 | 20 | 15.17 | 1323 | 401 | 2.96 / 104.08 | 2 | 15 |
5 | 13 | 196.76 | 20 | 15.28 | 584 | 178 | 3.13 / 104.26 | 2 | 14 |
6 | 13 | 33.40 | 20 | 15.31 | 365 | 112 | 3.25 / 104.37 | 2 | 14 |
7 | 8 | -0.04 | 165 | 15.26 | 309 | 778 | 4.02 / 105.15 | 2 | 20 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 32 | 15.24 | 441 | 215 | 0.22 / 97.37 | 3 | 3 |
2 | 7 | 1910.08 | 38 | 14.99 | 2786 | 1587 | 1.80 / 98.95 | 2 | 9 |
3 | 13 | 1430.04 | 20 | 15.05 | 2205 | 664 | 2.47 / 99.62 | 2 | 12 |
4 | 13 | 778.72 | 20 | 15.18 | 1368 | 415 | 2.88 / 100.03 | 2 | 15 |
5 | 13 | 255.12 | 20 | 15.29 | 671 | 205 | 3.09 / 100.24 | 2 | 15 |
6 | 13 | 31.08 | 20 | 15.32 | 363 | 111 | 3.20 / 100.35 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.27 | 307 | 774 | 3.97 / 101.12 | 2 | 16 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 32 | 15.24 | 452 | 220 | 0.22 / 93.28 | 3 | 3 |
2 | 7 | 2005.08 | 38 | 14.98 | 2907 | 1655 | 1.88 / 94.93 | 2 | 7 |
3 | 13 | 1435.04 | 20 | 15.06 | 2211 | 666 | 2.54 / 95.60 | 2 | 11 |
4 | 13 | 930.40 | 20 | 15.13 | 1566 | 474 | 3.02 / 96.07 | 2 | 13 |
5 | 13 | 200.40 | 20 | 15.29 | 597 | 183 | 3.20 / 96.26 | 2 | 13 |
6 | 13 | 49.32 | 20 | 15.31 | 391 | 120 | 3.32 / 96.38 | 2 | 13 |
7 | 8 | 0.12 | 165 | 15.27 | 307 | 774 | 4.09 / 97.15 | 2 | 18 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 31 | 15.24 | 461 | 218 | 0.22 / 89.27 | 2 | 3 |
2 | 7 | 2015.48 | 38 | 14.97 | 2918 | 1660 | 1.88 / 90.93 | 2 | 7 |
3 | 13 | 1400.12 | 20 | 15.05 | 2171 | 653 | 2.53 / 91.59 | 2 | 11 |
4 | 13 | 833.96 | 20 | 15.15 | 1438 | 436 | 2.97 / 92.02 | 2 | 14 |
5 | 13 | 133.32 | 20 | 15.31 | 503 | 154 | 3.12 / 92.18 | 2 | 13 |
6 | 13 | 25.16 | 20 | 15.31 | 355 | 109 | 3.23 / 92.28 | 2 | 12 |
7 | 8 | 0.12 | 165 | 15.26 | 308 | 776 | 4.01 / 93.06 | 2 | 19 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 31 | 15.26 | 446 | 211 | 0.21 / 85.34 | 3 | 3 |
2 | 7 | 1937.44 | 38 | 14.99 | 2821 | 1607 | 1.82 / 86.94 | 2 | 12 |
3 | 13 | 1357.08 | 20 | 15.07 | 2102 | 634 | 2.45 / 87.58 | 2 | 15 |
4 | 13 | 814.16 | 20 | 15.17 | 1414 | 429 | 2.88 / 88.01 | 2 | 17 |
5 | 13 | 155.84 | 20 | 15.30 | 535 | 164 | 3.04 / 88.17 | 2 | 16 |
6 | 13 | 24.44 | 20 | 15.32 | 354 | 108 | 3.15 / 88.28 | 2 | 14 |
7 | 8 | -0.20 | 165 | 15.27 | 308 | 776 | 3.93 / 89.05 | 2 | 18 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 31 | 15.29 | 448 | 212 | 0.21 / 81.61 | 2 | 3 |
2 | 7 | 1732.92 | 38 | 15.07 | 2566 | 1469 | 1.68 / 83.08 | 2 | 10 |
3 | 13 | 1318.48 | 20 | 15.11 | 2060 | 623 | 2.30 / 83.71 | 2 | 13 |
4 | 13 | 678.52 | 20 | 15.22 | 1232 | 375 | 2.68 / 84.08 | 2 | 15 |
5 | 13 | 130.72 | 20 | 15.33 | 499 | 153 | 2.83 / 84.23 | 2 | 13 |
6 | 13 | 40.92 | 20 | 15.33 | 376 | 115 | 2.95 / 84.35 | 2 | 12 |
7 | 8 | 0.12 | 165 | 15.29 | 308 | 777 | 3.72 / 85.13 | 2 | 19 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 31 | 15.28 | 443 | 210 | 0.21 / 78.35 | 3 | 3 |
2 | 7 | 1204.00 | 38 | 15.26 | 1901 | 1102 | 1.31 / 79.45 | 2 | 11 |
3 | 13 | 1171.36 | 20 | 15.23 | 1871 | 570 | 1.88 / 80.02 | 2 | 12 |
4 | 13 | 638.88 | 20 | 15.30 | 1182 | 362 | 2.24 / 80.38 | 2 | 14 |
5 | 13 | 73.04 | 20 | 15.38 | 425 | 131 | 2.37 / 80.51 | 2 | 14 |
6 | 13 | 43.96 | 20 | 15.38 | 382 | 118 | 2.49 / 80.63 | 2 | 13 |
7 | 8 | 0.04 | 165 | 15.33 | 306 | 774 | 3.27 / 81.40 | 2 | 19 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 31 | 15.24 | 435 | 206 | 0.21 / 74.66 | 3 | 3 |
2 | 7 | 1554.40 | 39 | 15.14 | 2339 | 1381 | 1.59 / 76.04 | 2 | 13 |
3 | 13 | 1365.92 | 20 | 15.14 | 2114 | 640 | 2.23 / 76.68 | 2 | 12 |
4 | 13 | 747.20 | 20 | 15.23 | 1328 | 405 | 2.63 / 77.08 | 2 | 15 |
5 | 13 | 161.40 | 20 | 15.35 | 540 | 166 | 2.80 / 77.25 | 2 | 14 |
6 | 13 | 48.88 | 20 | 15.34 | 385 | 118 | 2.92 / 77.37 | 2 | 14 |
7 | 8 | 0.08 | 165 | 15.30 | 304 | 767 | 3.68 / 78.14 | 2 | 19 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 31 | 15.23 | 446 | 211 | 0.21 / 70.47 | 3 | 3 |
2 | 7 | 2014.08 | 39 | 14.99 | 2910 | 1701 | 1.91 / 72.17 | 2 | 8 |
3 | 13 | 1452.00 | 20 | 15.06 | 2227 | 671 | 2.58 / 72.84 | 2 | 12 |
4 | 13 | 808.92 | 20 | 15.17 | 1413 | 429 | 3.01 / 73.27 | 2 | 15 |
5 | 13 | 234.92 | 20 | 15.29 | 643 | 197 | 3.21 / 73.47 | 2 | 15 |
6 | 13 | 53.20 | 20 | 15.32 | 389 | 119 | 3.33 / 73.58 | 2 | 14 |
7 | 13 | 30.24 | 20 | 15.31 | 349 | 107 | 3.43 / 73.69 | 2 | 14 |
8 | 8 | -0.04 | 165 | 15.27 | 302 | 761 | 4.19 / 74.45 | 2 | 21 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 31 | 15.25 | 425 | 201 | 0.20 / 66.35 | 2 | 3 |
2 | 7 | 2008.32 | 38 | 15.00 | 2903 | 1655 | 1.86 / 68.01 | 2 | 10 |
3 | 13 | 1474.08 | 20 | 15.08 | 2260 | 682 | 2.54 / 68.69 | 2 | 14 |
4 | 13 | 749.56 | 20 | 15.19 | 1334 | 405 | 2.94 / 69.09 | 2 | 17 |
5 | 13 | 206.52 | 20 | 15.30 | 603 | 185 | 3.13 / 69.28 | 2 | 16 |
6 | 13 | 41.88 | 20 | 15.33 | 374 | 115 | 3.24 / 69.39 | 2 | 14 |
7 | 13 | 17.08 | 20 | 15.32 | 334 | 102 | 3.34 / 69.49 | 2 | 14 |
8 | 8 | 0.20 | 165 | 15.28 | 303 | 764 | 4.11 / 70.26 | 2 | 19 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 31 | 15.25 | 439 | 208 | 0.21 / 62.18 | 3 | 3 |
2 | 7 | 2006.72 | 38 | 15.00 | 2904 | 1655 | 1.86 / 63.84 | 2 | 11 |
3 | 13 | 1406.92 | 20 | 15.08 | 2175 | 656 | 2.52 / 64.49 | 2 | 15 |
4 | 13 | 946.60 | 20 | 15.15 | 1590 | 482 | 3.00 / 64.98 | 2 | 16 |
5 | 13 | 203.12 | 20 | 15.30 | 597 | 183 | 3.18 / 65.16 | 2 | 15 |
6 | 13 | 41.32 | 20 | 15.33 | 374 | 115 | 3.30 / 65.27 | 2 | 14 |
7 | 13 | 15.72 | 20 | 15.33 | 336 | 103 | 3.40 / 65.38 | 2 | 15 |
8 | 8 | -0.12 | 165 | 15.28 | 307 | 774 | 4.17 / 66.15 | 2 | 20 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 31 | 15.26 | 446 | 211 | 0.21 / 57.98 | 2 | 3 |
2 | 7 | 2011.40 | 39 | 15.01 | 2904 | 1700 | 1.91 / 59.68 | 2 | 8 |
3 | 13 | 1458.88 | 20 | 15.08 | 2241 | 676 | 2.59 / 60.36 | 2 | 12 |
4 | 13 | 814.40 | 20 | 15.18 | 1417 | 430 | 3.02 / 60.79 | 2 | 15 |
5 | 13 | 242.32 | 20 | 15.31 | 654 | 200 | 3.22 / 60.99 | 2 | 15 |
6 | 13 | 45.64 | 20 | 15.33 | 378 | 116 | 3.33 / 61.10 | 2 | 13 |
7 | 13 | 12.64 | 20 | 15.32 | 330 | 101 | 3.43 / 61.21 | 2 | 13 |
8 | 8 | 0.24 | 165 | 15.28 | 305 | 769 | 4.20 / 61.97 | 2 | 19 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 31 | 15.25 | 445 | 210 | 0.21 / 53.93 | 3 | 3 |
2 | 7 | 2005.32 | 39 | 15.01 | 2900 | 1698 | 1.91 / 55.63 | 2 | 11 |
3 | 13 | 1423.28 | 20 | 15.09 | 2198 | 663 | 2.57 / 56.29 | 2 | 12 |
4 | 13 | 820.04 | 20 | 15.19 | 1422 | 432 | 3.00 / 56.72 | 2 | 15 |
5 | 13 | 119.36 | 20 | 15.34 | 486 | 149 | 3.15 / 56.87 | 2 | 13 |
6 | 13 | 39.48 | 20 | 15.34 | 373 | 114 | 3.27 / 56.99 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.30 | 311 | 785 | 4.05 / 57.77 | 2 | 19 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 31 | 15.26 | 437 | 207 | 0.21 / 49.89 | 3 | 3 |
2 | 7 | 2010.32 | 38 | 15.01 | 2907 | 1658 | 1.86 / 51.54 | 2 | 11 |
3 | 13 | 1509.56 | 20 | 15.06 | 2302 | 693 | 2.56 / 52.24 | 2 | 12 |
4 | 13 | 765.36 | 20 | 15.20 | 1357 | 413 | 2.97 / 52.65 | 2 | 15 |
5 | 13 | 150.12 | 20 | 15.33 | 533 | 163 | 3.13 / 52.81 | 2 | 13 |
6 | 13 | 65.32 | 20 | 15.33 | 415 | 127 | 3.26 / 52.94 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.29 | 309 | 780 | 4.04 / 53.72 | 2 | 19 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 31 | 15.26 | 444 | 210 | 0.21 / 45.97 | 3 | 3 |
2 | 7 | 2003.80 | 38 | 15.01 | 2901 | 1655 | 1.86 / 47.62 | 2 | 11 |
3 | 13 | 1358.60 | 20 | 15.10 | 2107 | 636 | 2.50 / 48.26 | 2 | 12 |
4 | 13 | 747.76 | 20 | 15.20 | 1328 | 404 | 2.90 / 48.66 | 2 | 15 |
5 | 13 | 84.64 | 20 | 15.36 | 436 | 134 | 3.04 / 48.79 | 2 | 13 |
6 | 13 | 37.88 | 20 | 15.35 | 366 | 112 | 3.15 / 48.91 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.30 | 306 | 772 | 3.92 / 49.68 | 2 | 17 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 31 | 15.26 | 448 | 212 | 0.21 / 41.92 | 3 | 3 |
2 | 7 | 2011.36 | 38 | 15.02 | 2906 | 1659 | 1.87 / 43.58 | 2 | 8 |
3 | 13 | 1512.88 | 20 | 15.08 | 2311 | 697 | 2.57 / 44.28 | 2 | 12 |
4 | 13 | 766.84 | 20 | 15.20 | 1358 | 413 | 2.98 / 44.69 | 2 | 15 |
5 | 13 | 175.12 | 20 | 15.32 | 565 | 173 | 3.15 / 44.87 | 2 | 13 |
6 | 13 | 45.44 | 20 | 15.35 | 379 | 116 | 3.27 / 44.98 | 2 | 12 |
7 | 8 | 0.04 | 165 | 15.30 | 306 | 772 | 4.04 / 45.76 | 2 | 19 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 15.25 | 441 | 202 | 0.20 / 37.17 | 2 | 3 |
2 | 3 | 1040.36 | 1 | 15.34 | 1774 | 27 | 0.23 / 37.20 | 2 | 8 |
3 | 7 | 2011.20 | 74 | 14.90 | 2890 | 3187 | 3.42 / 40.39 | 2 | 9 |
4 | 13 | 607.60 | 18 | 15.24 | 1147 | 315 | 3.73 / 40.70 | 2 | 15 |
5 | 13 | 63.96 | 18 | 15.34 | 414 | 114 | 3.84 / 40.82 | 2 | 13 |
6 | 13 | 40.84 | 18 | 15.33 | 382 | 105 | 3.95 / 40.92 | 2 | 13 |
7 | 8 | 0.20 | 165 | 15.29 | 313 | 790 | 4.74 / 41.71 | 2 | 18 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 29 | 15.30 | 472 | 209 | 0.21 / 32.43 | 2 | 3 |
2 | 3 | 1016.68 | 1 | 15.36 | 1728 | 27 | 0.24 / 32.46 | 2 | 7 |
3 | 7 | 2004.52 | 75 | 14.90 | 2879 | 3217 | 3.45 / 35.68 | 2 | 9 |
4 | 13 | 553.96 | 18 | 15.25 | 1069 | 293 | 3.75 / 35.97 | 2 | 15 |
5 | 13 | 60.20 | 18 | 15.35 | 407 | 112 | 3.86 / 36.08 | 2 | 13 |
6 | 13 | 34.88 | 18 | 15.34 | 367 | 101 | 3.96 / 36.19 | 2 | 13 |
7 | 8 | 0.04 | 165 | 15.30 | 312 | 788 | 4.75 / 36.97 | 2 | 19 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 29 | 15.26 | 464 | 205 | 0.21 / 28.67 | 2 | 3 |
2 | 3 | 1034.44 | 1 | 15.34 | 1755 | 27 | 0.23 / 28.70 | 2 | 8 |
3 | 7 | 1502.56 | 74 | 15.09 | 2258 | 2521 | 2.75 / 31.22 | 2 | 12 |
4 | 13 | 48.64 | 18 | 15.40 | 391 | 108 | 2.86 / 31.33 | 2 | 13 |
5 | 13 | 34.44 | 18 | 15.40 | 371 | 103 | 2.96 / 31.43 | 2 | 14 |
6 | 8 | 0.04 | 165 | 15.34 | 313 | 792 | 3.76 / 32.23 | 2 | 19 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 29 | 15.24 | 462 | 204 | 0.20 / 24.26 | 2 | 3 |
2 | 7 | 1817.04 | 74 | 14.94 | 2645 | 2924 | 3.13 / 27.18 | 2 | 9 |
3 | 13 | 536.92 | 18 | 15.23 | 1054 | 289 | 3.42 / 27.47 | 2 | 14 |
4 | 13 | 47.08 | 18 | 15.34 | 391 | 108 | 3.53 / 27.58 | 2 | 13 |
5 | 13 | 31.28 | 18 | 15.34 | 366 | 101 | 3.63 / 27.68 | 2 | 13 |
6 | 8 | 0.04 | 165 | 15.29 | 313 | 790 | 4.42 / 28.47 | 2 | 19 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 28 | 15.25 | 462 | 197 | 0.20 / 19.91 | 2 | 3 |
2 | 3 | 1042.52 | 1 | 15.34 | 1762 | 27 | 0.22 / 19.94 | 2 | 8 |
3 | 7 | 1812.84 | 74 | 14.94 | 2630 | 2908 | 3.13 / 22.84 | 2 | 9 |
4 | 13 | 318.92 | 18 | 15.30 | 758 | 209 | 3.34 / 23.05 | 2 | 14 |
5 | 13 | 45.04 | 18 | 15.34 | 386 | 107 | 3.45 / 23.16 | 2 | 13 |
6 | 13 | 15.20 | 18 | 15.33 | 343 | 95 | 3.54 / 23.25 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.29 | 316 | 797 | 4.34 / 24.05 | 2 | 19 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 28 | 15.29 | 466 | 200 | 0.20 / 15.56 | 2 | 3 |
2 | 7 | 1815.08 | 74 | 14.95 | 2638 | 2918 | 3.12 / 18.48 | 2 | 9 |
3 | 13 | 434.04 | 18 | 15.26 | 907 | 249 | 3.37 / 18.73 | 2 | 14 |
4 | 13 | 43.60 | 18 | 15.33 | 380 | 105 | 3.47 / 18.83 | 2 | 13 |
5 | 13 | 20.24 | 18 | 15.33 | 347 | 96 | 3.57 / 18.93 | 2 | 14 |
6 | 8 | 0.00 | 165 | 15.28 | 312 | 787 | 4.35 / 19.71 | 2 | 19 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 28 | 15.30 | 464 | 199 | 0.20 / 12.06 | 2 | 3 |
2 | 7 | 1361.84 | 74 | 15.11 | 2074 | 2319 | 2.52 / 14.37 | 2 | 11 |
3 | 13 | 28.32 | 18 | 15.38 | 357 | 99 | 2.62 / 14.47 | 2 | 12 |
4 | 13 | 14.52 | 18 | 15.37 | 339 | 94 | 2.71 / 14.57 | 2 | 13 |
5 | 8 | -0.12 | 165 | 15.32 | 313 | 791 | 3.50 / 15.36 | 2 | 16 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 27 | 15.26 | 451 | 186 | 0.19 / 8.76 | 2 | 3 |
2 | 3 | 1053.08 | 2 | 15.33 | 1765 | 54 | 0.24 / 8.81 | 2 | 8 |
3 | 7 | 1245.32 | 74 | 15.15 | 1922 | 2155 | 2.39 / 10.97 | 2 | 12 |
4 | 13 | 38.56 | 18 | 15.39 | 373 | 103 | 2.50 / 11.07 | 2 | 14 |
5 | 8 | 0.08 | 165 | 15.34 | 311 | 787 | 3.29 / 11.86 | 2 | 17 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 31 | 15.29 | 461 | 219 | 0.22 / 4.89 | 2 | 3 |
2 | 3 | 868.76 | -2 | 15.64 | 0 | 0 | 0.00 / 4.89 | 2 | 3 |
3 | 3 | 935.96 | -1 | 15.67 | 0 | 0 | 0.00 / 4.89 | 2 | 3 |
4 | 7 | 1526.32 | 74 | 15.04 | 2275 | 2532 | 2.75 / 7.42 | 2 | 10 |
5 | 13 | 268.20 | 18 | 15.31 | 675 | 186 | 2.94 / 7.61 | 2 | 14 |
6 | 13 | 32.32 | 18 | 15.36 | 359 | 99 | 3.04 / 7.70 | 2 | 13 |
7 | 13 | 11.56 | 18 | 15.35 | 325 | 90 | 3.13 / 7.79 | 2 | 13 |
8 | 8 | 0.12 | 165 | 15.29 | 308 | 777 | 3.90 / 8.57 | 2 | 18 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 26 | 15.45 | 424 | 170 | 0.17 / 1.96 | 3 | 3 |
2 | 3 | 1051.52 | 1 | 15.36 | 1769 | 27 | 0.20 / 1.99 | 2 | 7 |
3 | 7 | 999.08 | 74 | 15.20 | 1608 | 1809 | 2.01 / 3.79 | 2 | 13 |
4 | 13 | 30.00 | 18 | 15.39 | 351 | 97 | 2.10 / 3.89 | 2 | 14 |
5 | 8 | -0.08 | 165 | 15.34 | 307 | 777 | 2.88 / 4.67 | 2 | 18 |
Average= | 2.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 98.68 | 26 | 15.63 | 434 | 176 | 0.18 / 0.18 | 3 | 3 |
2 | 7 | 113.60 | 74 | 15.58 | 436 | 503 | 0.68 / 0.68 | 3 | 4 |
3 | 13 | 15.24 | 18 | 15.59 | 304 | 85 | 0.76 / 0.76 | 3 | 4 |
4 | 8 | -0.20 | 240 | 15.52 | 275 | 1024 | 1.79 / 1.79 | 3 | 19 |
Average= | 1.79 (KJ/cycle) |