Cycle 32 GMT 27/11/2023 4:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 29 15.19 466 205 0.21 / 126.30 2 4
2 7 2009.16 38 14.81 2972 1673 1.88 / 127.98 2 11
3 13 1318.48 20 14.97 2133 639 2.52 / 128.62 2 15
4 13 741.52 20 15.11 1381 417 2.93 / 129.03 2 17
5 13 86.88 20 15.31 485 149 3.08 / 129.18 2 17
6 13 43.52 20 15.31 423 130 3.21 / 129.31 2 11
7 13 24.28 20 15.29 386 118 3.33 / 129.43 2 12
8 8 0.16 165 15.25 328 825 4.16 / 130.25 2 19
Average= 3.95 (KJ/cycle)

Cycle 31 GMT 17/11/2023 9:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 15.19 511 225 0.23 / 122.14 2 3
2 7 2010.08 38 14.80 2963 1666 1.89 / 123.80 2 12
3 13 1358.84 20 14.95 2175 650 2.54 / 124.45 2 14
4 13 674.88 20 15.14 1300 394 2.94 / 124.85 2 18
5 13 89.16 20 15.30 482 147 3.08 / 124.99 2 14
6 13 61.16 20 15.30 447 137 3.22 / 125.13 2 15
7 13 41.12 20 15.29 411 126 3.35 / 125.26 2 13
8 8 0.20 165 15.25 335 843 4.19 / 126.10 2 16
Average= 3.94 (KJ/cycle)

Cycle 30 GMT 7/11/2023 12:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 15.18 468 206 0.21 / 117.90 2 3
2 7 2008.48 38 14.80 2975 1673 1.88 / 119.57 2 11
3 13 1328.40 20 14.95 2147 642 2.52 / 120.21 2 16
4 13 744.92 20 15.10 1394 421 2.94 / 120.63 2 17
5 13 86.08 20 15.29 487 149 3.09 / 120.78 2 14
6 13 59.36 20 15.29 453 139 3.23 / 120.92 2 13
7 13 42.72 20 15.28 415 127 3.36 / 121.05 2 15
8 8 0.20 165 15.24 343 863 4.22 / 121.91 2 15
Average= 3.93 (KJ/cycle)

Cycle 29 GMT 28/10/2023 15:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 15.21 464 205 0.20 / 113.71 2 3
2 7 2004.88 38 14.82 2970 1673 1.88 / 115.38 2 11
3 13 1330.76 20 14.97 2146 643 2.52 / 116.02 2 15
4 13 733.08 20 15.12 1378 417 2.94 / 116.44 2 17
5 13 89.24 20 15.30 490 150 3.09 / 116.59 2 13
6 13 61.80 20 15.30 449 137 3.22 / 116.72 2 16
7 13 46.64 20 15.30 424 130 3.35 / 116.85 2 14
8 8 0.24 165 15.25 333 838 4.19 / 117.69 2 16
Average= 3.92 (KJ/cycle)

Cycle 28 GMT 18/10/2023 20: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 15.22 474 209 0.21 / 109.54 2 3
2 7 2009.64 38 14.81 2973 1673 1.88 / 111.21 2 12
3 13 1350.92 20 14.97 2173 651 2.53 / 111.86 2 15
4 13 697.68 20 15.14 1345 407 2.94 / 112.27 2 17
5 13 103.32 20 15.32 499 153 3.09 / 112.42 2 13
6 13 58.12 20 15.31 434 133 3.23 / 112.55 2 13
7 13 40.40 20 15.30 409 125 3.35 / 112.68 2 15
8 8 0.28 165 15.26 327 823 4.17 / 113.50 2 18
Average= 3.91 (KJ/cycle)

Cycle 27 GMT 8/10/2023 21:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 15.20 463 204 0.20 / 105.31 2 3
2 7 2009.68 38 14.82 2975 1675 1.88 / 106.99 2 10
3 13 1391.64 20 14.98 2226 667 2.55 / 107.65 2 15
4 13 722.84 20 15.14 1368 414 2.96 / 108.07 2 17
5 13 86.64 20 15.34 479 147 3.11 / 108.21 2 15
6 13 64.76 20 15.33 455 140 3.25 / 108.35 2 13
7 13 40.24 20 15.31 411 126 3.37 / 108.48 2 13
8 8 0.04 165 15.27 336 847 4.22 / 109.33 2 18
Average= 3.90 (KJ/cycle)

Cycle 26 GMT 29/ 9/2023 0:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 29 15.22 456 201 0.20 / 101.09 2 3
2 7 2007.92 38 14.81 2979 1677 1.88 / 102.77 2 11
3 13 1430.96 20 14.96 2276 681 2.56 / 103.45 2 15
4 13 684.32 20 15.15 1306 396 2.95 / 103.84 2 17
5 13 89.84 20 15.33 496 152 3.11 / 104.00 2 16
6 13 65.60 20 15.32 455 139 3.25 / 104.13 2 16
7 13 43.12 20 15.30 418 128 3.37 / 104.26 2 16
8 8 -0.04 165 15.27 335 844 4.22 / 105.11 2 16
Average= 3.89 (KJ/cycle)

Cycle 25 GMT 19/ 9/2023 1: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 15.21 467 206 0.21 / 96.90 2 3
2 7 2006.96 38 14.83 2975 1677 1.88 / 98.57 2 13
3 13 1357.36 20 14.99 2187 656 2.54 / 99.23 2 16
4 13 712.64 20 15.14 1359 412 2.95 / 99.64 2 17
5 13 102.52 20 15.32 514 157 3.11 / 99.80 2 16
6 13 47.24 20 15.33 428 131 3.24 / 99.93 2 15
7 13 31.56 20 15.32 397 122 3.36 / 100.05 2 13
8 8 0.16 165 15.27 332 836 4.20 / 100.89 2 21
Average= 3.88 (KJ/cycle)

Cycle 24 GMT 9/ 9/2023 2: 5: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 15.23 468 207 0.21 / 92.66 2 3
2 7 2004.76 38 14.82 2978 1677 1.88 / 94.34 2 13
3 13 1403.92 20 14.97 2241 671 2.55 / 95.01 2 15
4 13 705.28 20 15.13 1349 408 2.96 / 95.42 2 16
5 13 150.32 20 15.30 576 176 3.14 / 95.59 2 16
6 13 53.12 20 15.32 433 133 3.27 / 95.73 2 14
7 13 32.80 20 15.31 395 121 3.39 / 95.85 2 16
8 8 0.16 165 15.26 336 846 4.24 / 96.69 2 20
Average= 3.87 (KJ/cycle)

Cycle 23 GMT 30/ 8/2023 3:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 29 15.24 476 210 0.21 / 88.39 2 3
2 7 2004.56 39 14.86 2960 1715 1.93 / 90.11 2 11
3 13 1377.76 20 15.00 2186 656 2.58 / 90.77 2 15
4 13 768.12 20 15.15 1431 434 3.02 / 91.20 2 17
5 13 71.00 20 15.36 464 143 3.16 / 91.34 2 14
6 13 49.72 20 15.34 435 133 3.29 / 91.48 2 15
7 13 32.20 20 15.34 407 125 3.42 / 91.60 2 15
8 8 0.04 165 15.30 338 853 4.27 / 92.45 2 16
Average= 3.85 (KJ/cycle)

Cycle 22 GMT 20/ 8/2023 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 15.22 491 217 0.22 / 84.22 2 3
2 7 2003.88 38 14.85 2980 1682 1.90 / 85.90 2 12
3 13 1339.32 20 14.99 2165 649 2.55 / 86.55 2 15
4 13 669.84 20 15.18 1287 391 2.94 / 86.94 2 18
5 13 85.16 20 15.35 478 147 3.08 / 87.09 2 14
6 13 49.76 20 15.34 430 132 3.22 / 87.22 2 13
7 13 28.00 20 15.34 391 120 3.34 / 87.34 2 16
8 8 0.04 165 15.30 335 846 4.18 / 88.18 2 17
Average= 3.83 (KJ/cycle)

Cycle 21 GMT 10/ 8/2023 6:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 15.24 457 202 0.20 / 80.00 2 3
2 7 2006.60 39 14.88 2956 1715 1.92 / 81.72 2 12
3 13 1309.72 20 15.02 2118 636 2.55 / 82.36 2 15
4 13 676.12 20 15.18 1297 394 2.95 / 82.75 2 17
5 13 112.52 20 15.36 515 158 3.11 / 82.91 2 15
6 13 56.16 20 15.35 434 133 3.24 / 83.04 2 14
7 13 34.16 20 15.34 398 122 3.36 / 83.16 2 16
8 8 0.12 165 15.30 332 838 4.20 / 84.00 2 17
Average= 3.82 (KJ/cycle)

Cycle 20 GMT 31/ 7/2023 11:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 29 15.23 471 208 0.21 / 75.85 2 3
2 7 2006.04 38 14.85 2958 1669 1.88 / 77.52 2 11
3 13 1359.08 20 15.01 2175 653 2.53 / 78.18 2 15
4 13 683.16 20 15.18 1314 399 2.93 / 78.57 2 18
5 13 100.12 20 15.34 496 152 3.08 / 78.73 2 15
6 13 47.56 20 15.34 422 129 3.21 / 78.86 2 14
7 13 29.92 20 15.33 386 118 3.33 / 78.97 2 14
8 8 0.24 165 15.29 328 827 4.16 / 79.80 2 15
Average= 3.80 (KJ/cycle)

Cycle 19 GMT 21/ 7/2023 12:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 29 15.25 458 203 0.20 / 71.67 2 3
2 7 2006.28 38 14.86 2973 1679 1.88 / 73.35 2 11
3 13 1302.64 20 15.04 2116 636 2.52 / 73.99 2 15
4 13 697.52 20 15.18 1341 407 2.92 / 74.40 2 17
5 13 128.80 20 15.35 543 167 3.09 / 74.56 2 14
6 13 49.36 20 15.36 426 131 3.22 / 74.69 2 13
7 13 27.92 20 15.35 387 119 3.34 / 74.81 2 13
8 8 0.24 165 15.30 330 833 4.17 / 75.65 2 17
Average= 3.78 (KJ/cycle)

Cycle 18 GMT 11/ 7/2023 13:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 15.24 466 206 0.21 / 67.67 2 3
2 7 2002.80 38 14.87 2947 1665 1.87 / 69.33 2 10
3 13 1321.84 20 15.05 2114 636 2.51 / 69.97 2 14
4 13 618.28 20 15.22 1223 372 2.88 / 70.34 2 16
5 13 105.64 20 15.35 514 158 3.04 / 70.50 2 15
6 13 56.04 20 15.35 441 135 3.17 / 70.63 2 15
7 8 0.16 165 15.31 332 839 4.01 / 71.47 2 12
Average= 3.76 (KJ/cycle)

Cycle 17 GMT 1/ 7/2023 13:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 29 15.25 494 218 0.22 / 63.43 2 3
2 7 2006.24 38 14.89 2968 1679 1.90 / 65.11 2 10
3 13 1405.32 20 15.02 2249 676 2.57 / 65.79 2 14
4 13 701.48 20 15.20 1344 409 2.98 / 66.19 2 16
5 13 91.92 20 15.39 495 152 3.13 / 66.35 2 14
6 13 56.12 20 15.39 440 135 3.27 / 66.48 2 13
7 13 34.00 20 15.37 407 125 3.39 / 66.61 2 14
8 8 0.12 165 15.33 337 852 4.25 / 67.46 2 23
Average= 3.75 (KJ/cycle)

Cycle 16 GMT 21/ 6/2023 15:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 15.27 474 210 0.21 / 59.31 2 3
2 7 2005.04 38 14.89 2976 1684 1.89 / 60.99 2 11
3 13 1345.24 20 15.03 2171 653 2.55 / 61.64 2 15
4 13 736.60 20 15.18 1388 421 2.97 / 62.06 2 17
5 13 99.32 20 15.37 506 156 3.12 / 62.22 2 13
6 13 66.64 20 15.37 459 141 3.26 / 62.36 2 14
7 8 0.12 165 15.32 337 852 4.12 / 63.21 2 19
Average= 3.72 (KJ/cycle)

Cycle 15 GMT 11/ 6/2023 15:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 15.30 479 213 0.21 / 55.20 2 3
2 7 2008.60 38 14.88 2971 1680 1.89 / 56.88 2 11
3 13 1348.84 20 15.02 2172 652 2.54 / 57.53 2 14
4 13 742.88 20 15.17 1391 422 2.97 / 57.96 2 16
5 13 124.72 20 15.35 536 165 3.13 / 58.12 2 14
6 13 53.36 20 15.36 430 132 3.26 / 58.25 2 13
7 8 0.04 165 15.32 334 844 4.11 / 59.10 2 12
Average= 3.69 (KJ/cycle)

Cycle 14 GMT 1/ 6/2023 17:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 15.31 471 209 0.21 / 51.78 2 3
2 7 1601.40 38 15.06 2473 1415 1.62 / 53.20 2 12
3 13 891.08 20 15.23 1588 484 2.11 / 53.68 2 16
4 13 193.88 20 15.41 632 195 2.30 / 53.88 2 14
5 13 60.80 20 15.42 447 138 2.44 / 54.01 2 13
6 13 33.60 20 15.41 406 125 2.57 / 54.14 2 14
7 8 0.20 165 15.36 335 849 3.41 / 54.99 2 17
Average= 3.67 (KJ/cycle)

Cycle 13 GMT 22/ 5/2023 20:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 15.29 473 203 0.20 / 48.68 2 3
2 7 1485.72 39 15.10 2291 1349 1.55 / 50.03 2 13
3 13 680.28 20 15.30 1305 399 1.95 / 50.43 2 16
4 13 75.84 20 15.43 471 145 2.10 / 50.58 2 13
5 13 53.32 20 15.43 437 135 2.23 / 50.71 2 13
6 8 0.16 165 15.38 340 863 3.09 / 51.57 2 18
Average= 3.68 (KJ/cycle)

Cycle 12 GMT 12/ 5/2023 23:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 15.30 466 200 0.20 / 45.08 2 3
2 7 1742.28 38 15.00 2651 1511 1.71 / 46.59 2 11
3 13 965.76 20 15.18 1683 511 2.22 / 47.10 2 15
4 13 344.72 20 15.34 843 259 2.48 / 47.36 2 15
5 13 55.20 20 15.40 438 135 2.62 / 47.49 2 14
6 13 33.64 20 15.39 405 125 2.74 / 47.62 2 13
7 8 0.20 165 15.34 341 863 3.60 / 48.48 2 19
Average= 3.73 (KJ/cycle)

Cycle 11 GMT 3/ 5/2023 2: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 28 15.25 484 207 0.21 / 41.82 2 3
2 7 1617.76 38 15.04 2477 1416 1.62 / 43.24 2 12
3 13 800.24 20 15.24 1466 447 2.07 / 43.69 2 16
4 13 168.20 20 15.39 604 186 2.26 / 43.87 2 15
5 13 37.44 20 15.41 413 127 2.38 / 44.00 2 14
6 8 0.20 165 15.37 346 877 3.26 / 44.88 2 17
Average= 3.74 (KJ/cycle)

Cycle 10 GMT 23/ 4/2023 4:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 28 15.26 491 210 0.21 / 36.94 2 3
2 3 1017.56 1 15.32 1784 27 0.24 / 36.97 2 9
3 7 2007.64 74 14.79 2952 3231 3.47 / 40.20 2 11
4 13 496.76 18 15.26 1054 290 3.76 / 40.49 2 17
5 13 54.24 18 15.37 446 123 3.88 / 40.62 2 14
6 13 37.52 18 15.37 421 116 4.00 / 40.73 2 14
7 8 0.16 165 15.32 350 885 4.88 / 41.62 2 18
Average= 3.78 (KJ/cycle)

Cycle 9 GMT 13/ 4/2023 7: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 26 15.25 472 187 0.19 / 32.06 2 3
2 10 1011.36 2 15.26 1764 54 0.24 / 32.11 2 7
3 7 2003.20 75 14.80 2926 3248 3.49 / 35.36 2 9
4 13 418.24 18 15.28 958 263 3.75 / 35.62 2 15
5 13 44.32 18 15.38 429 119 3.87 / 35.74 2 12
6 13 20.24 18 15.37 393 109 3.98 / 35.85 2 12
7 8 0.20 165 15.33 349 883 4.86 / 36.73 2 15
Average= 3.67 (KJ/cycle)

Cycle 8 GMT 3/ 4/2023 9:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 29 15.28 501 222 0.22 / 27.26 2 3
2 3 934.96 -1 15.66 0 0 0.00 / 27.26 2 3
3 3 967.52 -1 15.69 0 0 0.00 / 27.26 2 3
4 7 2003.76 74 14.78 2946 3222 3.44 / 30.48 2 11
5 13 469.56 18 15.26 1028 282 3.73 / 30.76 2 16
6 13 45.92 18 15.36 430 119 3.85 / 30.88 2 13
7 13 28.08 18 15.36 404 112 3.96 / 30.99 2 13
8 8 0.16 165 15.32 347 877 4.83 / 31.87 2 18
Average= 3.54 (KJ/cycle)

Cycle 7 GMT 24/ 3/2023 12: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 26 15.24 481 191 0.19 / 23.79 2 3
2 3 1033.68 1 15.28 1816 28 0.22 / 23.82 2 10
3 7 1169.40 74 15.10 1899 2122 2.34 / 25.94 2 14
4 13 31.00 18 15.41 403 112 2.45 / 26.05 2 15
5 13 14.96 18 15.40 380 105 2.56 / 26.16 2 14
6 8 0.20 165 15.35 348 881 3.44 / 27.04 2 17
Average= 3.38 (KJ/cycle)

Cycle 6 GMT 23/ 3/2023 8:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 26 15.29 506 201 0.20 / 19.32 2 3
2 7 1804.92 74 14.83 2699 2962 3.16 / 22.28 2 11
3 13 373.48 18 15.25 880 242 3.40 / 22.52 2 16
4 13 29.00 18 15.35 401 111 3.52 / 22.63 2 13
5 13 23.28 18 15.34 391 108 3.62 / 22.74 2 14
6 8 0.20 165 15.28 340 857 4.48 / 23.60 2 16
Average= 3.37 (KJ/cycle)

Cycle 5 GMT 22/ 3/2023 7:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 26 15.29 503 200 0.20 / 15.97 2 3
2 7 1105.36 74 15.14 1817 2036 2.24 / 18.01 2 14
3 13 30.20 18 15.44 403 112 2.35 / 18.12 2 14
4 13 11.00 18 15.43 381 106 2.45 / 18.23 2 14
5 8 0.20 165 15.37 352 893 3.35 / 19.12 2 19
Average= 3.19 (KJ/cycle)

Cycle 4 GMT 21/ 3/2023 8:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 26 15.30 482 192 0.19 / 12.63 2 3
2 7 1105.40 74 15.14 1819 2038 2.23 / 14.67 2 14
3 13 23.40 18 15.44 397 110 2.34 / 14.78 2 14
4 13 14.80 18 15.42 384 107 2.45 / 14.88 2 14
5 8 0.08 165 15.36 351 890 3.34 / 15.77 2 18
Average= 3.15 (KJ/cycle)

Cycle 3 GMT 20/ 3/2023 9: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 24 15.25 471 172 0.17 / 9.31 2 3
2 10 1009.24 2 15.25 1742 53 0.23 / 9.36 2 6
3 7 1070.60 74 15.16 1769 1985 2.21 / 11.35 2 14
4 13 25.44 18 15.44 394 110 2.32 / 11.46 2 15
5 13 15.20 18 15.43 379 105 2.42 / 11.56 2 14
6 8 0.16 165 15.37 344 872 3.30 / 12.44 2 16
Average= 3.11 (KJ/cycle)

Cycle 2 GMT 19/ 3/2023 9:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 31 15.29 504 239 0.24 / 5.31 2 3
2 3 810.32 -4 15.67 0 0 0.00 / 5.31 2 3
3 3 937.40 -1 15.70 0 0 0.00 / 5.31 2 3
4 7 1513.88 74 14.98 2326 2578 2.82 / 7.89 2 10
5 13 150.56 18 15.36 572 158 2.98 / 8.05 2 13
6 13 33.76 18 15.38 407 113 3.09 / 8.16 2 12
7 13 19.52 18 15.37 389 108 3.20 / 8.27 2 13
8 8 0.24 165 15.32 343 867 4.06 / 9.14 2 17
Average= 3.05 (KJ/cycle)

Cycle 1 GMT 18/ 3/2023 9:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 26 15.46 438 176 0.18 / 2.12 2 3
2 7 981.08 74 15.16 1652 1853 2.03 / 3.98 2 13
3 13 27.24 18 15.43 394 109 2.14 / 4.08 2 14
4 13 8.92 18 15.42 376 104 2.24 / 4.19 2 14
5 8 0.24 165 15.36 350 887 3.13 / 5.08 2 17
Average= 2.54 (KJ/cycle)

Cycle 0 GMT 17/ 3/2023 23:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.40 26 15.63 492 200 0.20 / 0.20 2 3
2 7 175.36 74 15.60 504 582 0.78 / 0.78 2 4
3 13 13.88 18 15.61 291 82 0.86 / 0.86 2 5
4 8 0.20 240 15.55 290 1082 1.95 / 1.95 2 17
Average= 1.95 (KJ/cycle)