SIO Argo Site:
Pump Diagnostics Page   



Serial= 8566 WMO= 3901276

Return

←PreviousNext→

Bug in float firmware: Transmitted values shaded red are not valid


Cycle 251 GMT 16/ 6/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.91 0 0 0.00 / 1059.59 2 2
2 7 2007.68 47 14.06 2919 1929 1.93 / 1061.52 2 2
3 13 1485.56 21 14.18 2325 692 2.62 / 1062.21 2 2
4 13 1072.96 21 14.30 1792 538 3.16 / 1062.75 2 2
5 13 353.60 21 14.64 833 256 3.42 / 1063.00 2 2
6 8 0.16 165 14.82 305 746 4.16 / 1063.75 2 2
Average= 4.22
(KJ/cycle)

Cycle 250 GMT 6/ 6/2024 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.90 0 0 0.00 / 1055.40 2 2
2 7 2008.40 46 14.07 2917 1888 1.89 / 1057.29 2 2
3 13 1593.24 21 14.16 2460 732 2.62 / 1058.02 2 2
4 13 1021.32 21 14.33 1729 520 3.14 / 1058.54 2 2
5 13 432.32 21 14.59 943 289 3.43 / 1058.83 2 2
6 8 0.00 165 14.81 309 755 4.18 / 1059.59 2 2
Average= 4.22
(KJ/cycle)

Cycle 249 GMT 27/ 5/2024 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.90 0 0 0.00 / 1050.97 2 2
2 3 1028.24 1 15.24 0 0 0.00 / 1050.97 2 2
3 7 2005.32 46 14.08 2933 1900 1.90 / 1052.87 2 2
4 13 1733.56 21 14.14 2605 774 2.67 / 1053.64 2 2
5 13 1144.24 21 14.29 1864 559 3.23 / 1054.20 2 2
6 13 545.04 21 14.53 1094 334 3.57 / 1054.54 2 2
7 13 52.44 21 14.81 383 119 3.69 / 1054.65 2 2
8 8 -0.04 165 14.80 307 750 4.44 / 1055.40 2 2
Average= 4.22
(KJ/cycle)

Cycle 248 GMT 17/ 5/2024 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 14.90 0 0 0.00 / 1046.65 2 2
2 3 966.28 -1 15.25 0 0 0.00 / 1046.65 2 2
3 7 2004.84 46 14.10 2909 1887 1.89 / 1048.53 2 2
4 13 1599.04 21 14.17 2455 731 2.62 / 1049.27 2 2
5 13 1039.44 21 14.32 1748 526 3.14 / 1049.79 2 2
6 13 455.92 21 14.57 974 298 3.44 / 1050.09 2 2
7 13 70.40 21 14.80 412 128 3.57 / 1050.22 2 2
8 8 0.12 165 14.80 308 752 4.32 / 1050.97 2 2
Average= 4.22
(KJ/cycle)

Cycle 247 GMT 7/ 5/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.91 0 0 0.00 / 1042.34 2 2
2 7 2004.72 46 14.08 2919 1891 1.89 / 1044.23 2 2
3 13 1741.56 21 14.14 2615 776 2.67 / 1045.01 2 2
4 13 1033.88 21 14.33 1738 523 3.19 / 1045.53 2 2
5 13 332.44 21 14.64 804 247 3.44 / 1045.78 2 2
6 13 40.52 21 14.82 364 113 3.55 / 1045.89 2 2
7 8 0.08 165 14.80 309 755 4.31 / 1046.65 2 2
Average= 4.22
(KJ/cycle)

Cycle 246 GMT 27/ 4/2024 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 14.91 0 0 0.00 / 1037.87 2 2
2 7 2005.76 46 14.09 2924 1895 1.90 / 1039.77 2 2
3 13 1878.16 21 14.10 2817 834 2.73 / 1040.60 2 2
4 13 1262.76 21 14.24 2028 606 3.34 / 1041.21 2 2
5 13 381.40 21 14.62 871 267 3.60 / 1041.48 2 2
6 13 53.84 21 14.82 383 119 3.72 / 1041.60 2 2
7 8 0.44 165 14.81 306 748 4.47 / 1042.34 2 2
Average= 4.22
(KJ/cycle)

Cycle 245 GMT 17/ 4/2024 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.93 0 0 0.00 / 1033.49 2 2
2 7 2006.68 46 14.10 2921 1895 1.89 / 1035.38 2 2
3 13 1875.16 21 14.12 2802 831 2.73 / 1036.21 2 2
4 13 1013.44 21 14.35 1711 516 3.24 / 1036.73 2 2
5 13 439.96 21 14.59 949 291 3.53 / 1037.02 2 2
6 13 32.72 21 14.83 345 107 3.64 / 1037.13 2 2
7 8 0.24 165 14.81 305 745 4.38 / 1037.87 2 2
Average= 4.22
(KJ/cycle)

Cycle 244 GMT 7/ 4/2024 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.92 0 0 0.00 / 1029.31 2 2
2 7 2005.04 46 14.10 2939 1906 1.91 / 1031.21 2 2
3 13 1734.80 21 14.17 2595 772 2.68 / 1031.98 2 2
4 13 1022.44 21 14.35 1718 518 3.20 / 1032.50 2 2
5 13 337.88 21 14.66 810 249 3.45 / 1032.75 2 2
6 8 0.36 165 14.83 301 737 4.18 / 1033.49 2 2
Average= 4.22
(KJ/cycle)

Cycle 243 GMT 28/ 3/2024 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 29 14.92 0 0 0.00 / 1025.03 2 2
2 7 2002.04 47 14.11 2917 1934 1.93 / 1026.96 2 2
3 13 1590.92 21 14.20 2439 727 2.66 / 1027.69 2 2
4 13 1027.76 21 14.34 1730 521 3.18 / 1028.21 2 2
5 13 325.64 21 14.67 793 244 3.43 / 1028.46 2 2
6 13 33.32 21 14.84 348 108 3.54 / 1028.57 2 2
7 8 -0.04 165 14.82 303 741 4.28 / 1029.31 2 2
Average= 4.22
(KJ/cycle)

Cycle 242 GMT 18/ 3/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.93 0 0 0.00 / 1020.72 2 2
2 7 2009.12 46 14.10 2944 1909 1.91 / 1022.63 2 2
3 13 1599.44 21 14.20 2443 729 2.64 / 1023.36 2 2
4 13 1034.20 21 14.34 1739 524 3.16 / 1023.88 2 2
5 13 459.68 21 14.59 974 298 3.46 / 1024.18 2 2
6 13 38.08 21 14.84 357 111 3.57 / 1024.29 2 2
7 8 0.00 165 14.82 303 741 4.31 / 1025.03 2 2
Average= 4.22
(KJ/cycle)

Cycle 241 GMT 8/ 3/2024 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.93 0 0 0.00 / 1016.38 2 2
2 7 2005.16 46 14.11 2940 1908 1.91 / 1018.29 2 2
3 13 1739.96 21 14.17 2613 778 2.69 / 1019.07 2 2
4 13 1005.64 21 14.36 1702 513 3.20 / 1019.58 2 2
5 13 435.80 21 14.61 947 291 3.49 / 1019.87 2 2
6 13 30.16 21 14.85 342 107 3.60 / 1019.98 2 2
7 8 0.40 165 14.82 302 738 4.33 / 1020.72 2 2
Average= 4.22
(KJ/cycle)

Cycle 240 GMT 27/ 2/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 29 14.94 0 0 0.00 / 1012.06 2 2
2 7 2004.04 46 14.11 2930 1902 1.90 / 1013.96 2 2
3 13 1605.16 21 14.19 2467 735 2.64 / 1014.69 2 2
4 13 1156.72 21 14.30 1902 571 3.21 / 1015.26 2 2
5 13 402.56 21 14.63 900 277 3.48 / 1015.54 2 2
6 13 24.60 21 14.86 334 104 3.59 / 1015.64 2 2
7 8 0.08 165 14.83 302 739 4.33 / 1016.38 2 2
Average= 4.22
(KJ/cycle)

Cycle 239 GMT 17/ 2/2024 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 14.94 0 0 0.00 / 1007.61 2 2
2 7 2007.28 47 14.11 2940 1950 1.95 / 1009.56 2 2
3 13 1876.24 21 14.14 2790 828 2.78 / 1010.39 2 2
4 13 1024.52 21 14.36 1734 523 3.30 / 1010.92 2 2
5 13 459.28 21 14.60 977 300 3.60 / 1011.22 2 2
6 13 18.24 21 14.87 322 101 3.70 / 1011.32 2 2
7 8 0.20 165 14.84 302 739 4.44 / 1012.06 2 2
Average= 4.22
(KJ/cycle)

Cycle 238 GMT 7/ 2/2024 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.94 0 0 0.00 / 1003.38 2 2
2 7 2010.08 46 14.11 2943 1910 1.91 / 1005.29 2 2
3 13 1594.36 21 14.19 2464 734 2.64 / 1006.02 2 2
4 13 1145.68 21 14.31 1885 566 3.21 / 1006.59 2 2
5 13 425.00 21 14.62 932 286 3.50 / 1006.87 2 2
6 8 0.12 165 14.84 303 742 4.24 / 1007.61 2 2
Average= 4.22
(KJ/cycle)

Cycle 237 GMT 28/ 1/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.95 0 0 0.00 / 999.11 2 2
2 7 2005.96 46 14.11 2918 1894 1.89 / 1001.01 2 2
3 13 1742.60 21 14.17 2650 789 2.68 / 1001.80 2 2
4 13 878.20 21 14.43 1537 466 3.15 / 1002.26 2 2
5 13 341.28 21 14.68 818 252 3.40 / 1002.51 2 2
6 13 46.36 21 14.86 368 115 3.52 / 1002.63 2 2
7 8 0.24 165 14.84 305 747 4.26 / 1003.38 2 2
Average= 4.22
(KJ/cycle)

Cycle 236 GMT 18/ 1/2024 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.95 0 0 0.00 / 994.95 2 2
2 7 2006.52 46 14.11 2941 1909 1.91 / 996.86 2 2
3 13 1600.16 21 14.19 2469 736 2.64 / 997.59 2 2
4 13 899.20 21 14.42 1562 473 3.12 / 998.07 2 2
5 13 472.76 21 14.60 998 306 3.42 / 998.37 2 2
6 8 0.16 165 14.85 303 742 4.17 / 999.11 2 2
Average= 4.22
(KJ/cycle)

Cycle 235 GMT 8/ 1/2024 16:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 29 14.95 0 0 0.00 / 990.56 2 2
2 7 2002.32 47 14.11 2929 1942 1.94 / 992.51 2 2
3 13 1715.04 21 14.18 2591 772 2.71 / 993.28 2 2
4 13 1004.64 21 14.38 1704 515 3.23 / 993.79 2 2
5 13 428.16 21 14.63 945 290 3.52 / 994.08 2 2
6 13 63.44 21 14.85 400 125 3.64 / 994.21 2 2
7 8 0.00 165 14.85 302 740 4.38 / 994.95 2 2
Average= 4.22
(KJ/cycle)

Cycle 234 GMT 29/12/2023 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.96 0 0 0.00 / 986.25 2 2
2 7 2007.48 46 14.11 2948 1913 1.91 / 988.16 2 2
3 13 1753.44 21 14.17 2637 785 2.70 / 988.95 2 2
4 13 1021.44 21 14.37 1728 521 3.22 / 989.47 2 2
5 13 577.04 21 14.55 1141 349 3.57 / 989.82 2 2
6 8 -0.12 165 14.86 304 745 4.31 / 990.56 2 2
Average= 4.22
(KJ/cycle)

Cycle 233 GMT 19/12/2023 17:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 29 14.95 0 0 0.00 / 981.95 2 2
2 7 2003.44 46 14.12 2929 1902 1.90 / 983.85 2 2
3 13 1741.72 21 14.17 2616 778 2.68 / 984.63 2 2
4 13 1035.00 21 14.37 1746 527 3.21 / 985.16 2 2
5 13 603.60 21 14.54 1173 358 3.57 / 985.51 2 2
6 8 0.08 165 14.86 300 736 4.30 / 986.25 2 2
Average= 4.21
(KJ/cycle)

Cycle 232 GMT 9/12/2023 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 14.97 0 0 0.00 / 977.50 2 2
2 7 2006.28 47 14.11 2935 1946 1.95 / 979.45 2 2
3 13 1731.32 21 14.17 2623 781 2.73 / 980.23 2 2
4 13 1155.12 21 14.32 1904 573 3.30 / 980.80 2 2
5 13 416.96 21 14.65 925 285 3.58 / 981.09 2 2
6 13 55.84 21 14.87 383 120 3.70 / 981.21 2 2
7 8 -0.24 165 14.86 303 743 4.45 / 981.95 2 2
Average= 4.21
(KJ/cycle)

Cycle 231 GMT 29/11/2023 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.97 0 0 0.00 / 973.39 2 2
2 7 2003.52 46 14.12 2930 1903 1.90 / 975.29 2 2
3 13 1596.36 21 14.21 2459 734 2.64 / 976.02 2 2
4 13 910.32 21 14.42 1585 480 3.12 / 976.50 2 2
5 13 366.28 21 14.68 855 264 3.38 / 976.77 2 2
6 8 0.12 165 14.88 300 737 4.12 / 977.50 2 2
Average= 4.21
(KJ/cycle)

Cycle 230 GMT 19/11/2023 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.97 0 0 0.00 / 969.16 2 2
2 7 2005.00 46 14.12 2924 1899 1.90 / 971.06 2 2
3 13 1726.76 21 14.18 2630 783 2.68 / 971.84 2 2
4 13 1003.80 21 14.38 1702 514 3.20 / 972.36 2 2
5 13 432.04 21 14.64 940 289 3.49 / 972.65 2 2
6 8 0.24 165 14.88 301 739 4.22 / 973.39 2 2
Average= 4.21
(KJ/cycle)

Cycle 229 GMT 9/11/2023 19:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 14.97 0 0 0.00 / 964.96 2 2
2 7 2003.32 46 14.12 2928 1902 1.90 / 966.86 2 2
3 13 1593.68 21 14.21 2460 734 2.64 / 967.60 2 2
4 13 1011.76 21 14.38 1721 520 3.16 / 968.12 2 2
5 13 439.24 21 14.63 960 295 3.45 / 968.41 2 2
6 8 0.28 165 14.87 305 748 4.20 / 969.16 2 2
Average= 4.21
(KJ/cycle)

Cycle 228 GMT 30/10/2023 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 14.98 0 0 0.00 / 960.80 2 2
2 7 2005.16 46 14.12 2928 1902 1.90 / 962.70 2 2
3 13 1600.32 21 14.20 2483 740 2.64 / 963.44 2 2
4 13 1023.76 21 14.37 1733 523 3.17 / 963.97 2 2
5 13 317.08 21 14.72 788 244 3.41 / 964.21 2 2
6 8 0.28 165 14.87 306 751 4.16 / 964.96 2 2
Average= 4.21
(KJ/cycle)

Cycle 227 GMT 20/10/2023 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 14.99 0 0 0.00 / 956.50 2 2
2 7 2005.80 46 14.12 2946 1913 1.91 / 958.42 2 2
3 13 1874.88 21 14.14 2803 832 2.75 / 959.25 2 2
4 13 994.16 21 14.39 1696 513 3.26 / 959.76 2 2
5 13 427.84 21 14.65 938 289 3.55 / 960.05 2 2
6 8 -0.04 165 14.88 307 754 4.30 / 960.80 2 2
Average= 4.21
(KJ/cycle)

Cycle 226 GMT 10/10/2023 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 28 14.99 0 0 0.00 / 952.21 2 2
2 7 2006.04 46 14.12 2916 1894 1.89 / 954.11 2 2
3 13 1726.92 21 14.17 2624 781 2.67 / 954.89 2 2
4 13 1141.44 21 14.32 1894 570 3.24 / 955.46 2 2
5 13 418.52 21 14.66 927 285 3.53 / 955.74 2 2
6 8 0.16 165 14.88 309 759 4.29 / 956.50 2 2
Average= 4.21
(KJ/cycle)

Cycle 225 GMT 30/ 9/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 15.00 0 0 0.00 / 948.11 2 2
2 7 2005.44 46 14.10 2955 1917 1.92 / 950.02 2 2
3 13 1477.60 21 14.24 2329 696 2.61 / 950.72 2 2
4 13 914.80 21 14.42 1591 482 3.09 / 951.20 2 2
5 13 359.88 21 14.69 849 262 3.36 / 951.46 2 2
6 8 0.00 165 14.88 305 749 4.11 / 952.21 2 2
Average= 4.21
(KJ/cycle)

Cycle 224 GMT 20/ 9/2023 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 15.00 0 0 0.00 / 943.81 2 2
2 7 2003.00 46 14.11 2934 1904 1.90 / 945.71 2 2
3 13 1739.28 21 14.17 2624 781 2.69 / 946.49 2 2
4 13 1163.56 21 14.32 1916 576 3.26 / 947.07 2 2
5 13 435.72 21 14.65 952 293 3.55 / 947.36 2 2
6 8 0.00 165 14.90 304 747 4.30 / 948.11 2 2
Average= 4.21
(KJ/cycle)

Cycle 223 GMT 10/ 9/2023 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 28 15.00 0 0 0.00 / 939.55 2 2
2 7 2007.12 46 14.11 2923 1897 1.90 / 941.45 2 2
3 13 1740.48 21 14.16 2639 785 2.68 / 942.24 2 2
4 13 1009.00 21 14.38 1723 520 3.20 / 942.76 2 2
5 13 443.56 21 14.65 964 297 3.50 / 943.05 2 2
6 8 0.12 165 14.90 306 752 4.25 / 943.81 2 2
Average= 4.21
(KJ/cycle)

Cycle 222 GMT 31/ 8/2023 23:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 28 15.00 0 0 0.00 / 935.25 2 2
2 3 1023.28 1 15.30 0 0 0.00 / 935.25 2 2
3 7 2009.60 46 14.10 2940 1907 1.91 / 937.16 2 2
4 13 1732.76 21 14.16 2619 779 2.69 / 937.94 2 2
5 13 1155.72 21 14.32 1904 573 3.26 / 938.51 2 2
6 13 424.72 21 14.66 936 288 3.55 / 938.80 2 2
7 8 0.12 165 14.90 308 757 4.30 / 939.55 2 2
Average= 4.21
(KJ/cycle)

Cycle 221 GMT 22/ 8/2023 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 27 15.01 0 0 0.00 / 930.76 2 2
2 3 1026.20 1 15.30 0 0 0.00 / 930.76 2 2
3 7 2007.88 46 14.09 2936 1903 1.90 / 932.66 2 2
4 13 1594.84 21 14.20 2470 737 2.64 / 933.40 2 2
5 13 1027.28 21 14.37 1722 520 3.16 / 933.92 2 2
6 13 325.72 21 14.73 795 246 3.41 / 934.16 2 2
7 8 0.04 165 14.91 305 750 4.16 / 934.91 2 2
8 14 0.04 75 14.87 303 338 4.49 / 935.25 2 2
Average= 4.21
(KJ/cycle)

Cycle 220 GMT 12/ 8/2023 0:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 15.00 0 0 0.00 / 926.42 2 2
2 3 970.08 -1 15.30 0 0 0.00 / 926.42 2 2
3 7 2007.08 47 14.10 2932 1943 1.94 / 928.37 2 2
4 13 1734.32 21 14.16 2633 783 2.73 / 929.15 2 2
5 13 1159.08 21 14.32 1907 573 3.30 / 929.72 2 2
6 13 428.92 21 14.67 937 289 3.59 / 930.01 2 2
7 8 0.12 165 14.91 303 745 4.33 / 930.76 2 2
Average= 4.21
(KJ/cycle)

Cycle 219 GMT 2/ 8/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 15.02 0 0 0.00 / 922.30 2 2
2 7 2004.20 46 14.09 2938 1904 1.90 / 924.20 2 2
3 13 1472.40 21 14.23 2294 686 2.59 / 924.89 2 2
4 13 1055.64 21 14.35 1772 534 3.12 / 925.42 2 2
5 13 350.48 21 14.72 833 257 3.38 / 925.68 2 2
6 8 0.40 165 14.91 302 743 4.12 / 926.42 2 2
Average= 4.21
(KJ/cycle)

Cycle 218 GMT 23/ 7/2023 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.01 0 0 0.00 / 918.15 2 2
2 7 2005.72 46 14.10 2933 1902 1.90 / 920.06 2 2
3 13 1597.36 21 14.20 2462 734 2.64 / 920.79 2 2
4 13 1032.68 21 14.37 1733 523 3.16 / 921.31 2 2
5 13 327.28 21 14.74 798 247 3.41 / 921.56 2 2
6 8 0.04 165 14.92 301 741 4.15 / 922.30 2 2
Average= 4.21
(KJ/cycle)

Cycle 217 GMT 13/ 7/2023 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 15.01 0 0 0.00 / 913.94 2 2
2 7 2004.64 46 14.09 2930 1899 1.90 / 915.83 2 2
3 13 1734.04 21 14.15 2624 780 2.68 / 916.61 2 2
4 13 1006.88 21 14.39 1696 513 3.19 / 917.13 2 2
5 13 422.68 21 14.68 926 285 3.48 / 917.41 2 2
6 8 0.12 165 14.91 301 741 4.22 / 918.15 2 2
Average= 4.21
(KJ/cycle)

Cycle 216 GMT 3/ 7/2023 2:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.02 0 0 0.00 / 909.77 2 2
2 7 2002.96 46 14.10 2904 1884 1.88 / 911.66 2 2
3 13 1594.80 21 14.19 2432 725 2.61 / 912.38 2 2
4 13 1024.72 21 14.38 1723 520 3.13 / 912.90 2 2
5 13 446.48 21 14.66 957 295 3.42 / 913.20 2 2
6 8 0.12 165 14.91 300 738 4.16 / 913.94 2 2
Average= 4.21
(KJ/cycle)

Cycle 215 GMT 23/ 6/2023 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 29 15.01 0 0 0.00 / 905.65 2 2
2 7 2002.88 46 14.10 2909 1887 1.89 / 907.54 2 2
3 13 1585.68 21 14.20 2448 730 2.62 / 908.27 2 2
4 13 1029.76 21 14.38 1737 525 3.14 / 908.79 2 2
5 13 336.84 21 14.73 808 250 3.39 / 909.04 2 2
6 8 0.04 165 14.92 298 734 4.12 / 909.77 2 2
Average= 4.21
(KJ/cycle)

Cycle 214 GMT 13/ 6/2023 3:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 15.01 0 0 0.00 / 901.44 2 2
2 7 2007.76 46 14.09 2937 1904 1.90 / 903.35 2 2
3 13 1598.36 21 14.19 2450 730 2.63 / 904.08 2 2
4 13 1041.16 21 14.37 1748 527 3.16 / 904.60 2 2
5 13 451.64 21 14.65 970 298 3.46 / 904.90 2 2
6 8 0.28 165 14.91 304 748 4.21 / 905.65 2 2
Average= 4.21
(KJ/cycle)

Cycle 213 GMT 3/ 6/2023 4: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 15.01 0 0 0.00 / 897.14 2 2
2 7 2006.16 46 14.09 2926 1896 1.90 / 899.04 2 2
3 13 1604.72 21 14.18 2463 733 2.63 / 899.77 2 2
4 13 1027.44 21 14.38 1731 523 3.15 / 900.29 2 2
5 13 446.08 21 14.66 960 296 3.45 / 900.59 2 2
6 13 37.52 21 14.92 352 110 3.56 / 900.70 2 2
7 8 -0.04 165 14.90 303 745 4.30 / 901.44 2 2
Average= 4.21
(KJ/cycle)

Cycle 212 GMT 24/ 5/2023 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 15.02 0 0 0.00 / 892.82 2 2
2 7 2005.80 46 14.09 2939 1905 1.90 / 894.73 2 2
3 13 1578.92 21 14.19 2441 727 2.63 / 895.46 2 2
4 13 1014.12 21 14.38 1713 517 3.15 / 895.97 2 2
5 13 445.76 21 14.66 964 297 3.45 / 896.27 2 2
6 13 67.04 21 14.90 397 124 3.57 / 896.39 2 2
7 8 0.24 165 14.90 303 745 4.32 / 897.14 2 2
Average= 4.21
(KJ/cycle)

Cycle 211 GMT 14/ 5/2023 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 15.01 0 0 0.00 / 888.52 2 2
2 7 2009.56 46 14.09 2925 1896 1.90 / 890.41 2 2
3 13 1744.40 21 14.14 2655 788 2.68 / 891.20 2 2
4 13 1022.68 21 14.38 1717 518 3.20 / 891.72 2 2
5 13 329.32 21 14.74 804 249 3.45 / 891.97 2 2
6 13 43.48 21 14.92 361 113 3.56 / 892.08 2 2
7 8 0.20 165 14.91 301 741 4.31 / 892.82 2 2
Average= 4.21
(KJ/cycle)

Cycle 210 GMT 4/ 5/2023 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 15.03 0 0 0.00 / 884.07 2 2
2 7 2008.20 47 14.08 2945 1949 1.95 / 886.02 2 2
3 13 1599.44 21 14.19 2462 734 2.68 / 886.76 2 2
4 13 1163.68 21 14.32 1905 573 3.26 / 887.33 2 2
5 13 553.88 21 14.60 1105 339 3.59 / 887.67 2 2
6 13 28.20 21 14.93 341 107 3.70 / 887.78 2 2
7 8 0.28 165 14.90 302 742 4.44 / 888.52 2 2
Average= 4.21
(KJ/cycle)

Cycle 209 GMT 24/ 4/2023 5:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 15.02 0 0 0.00 / 879.74 2 2
2 7 2004.24 46 14.09 2929 1898 1.90 / 881.64 2 2
3 13 1743.84 21 14.15 2620 779 2.68 / 882.42 2 2
4 13 1023.80 21 14.39 1725 521 3.20 / 882.94 2 2
5 13 452.68 21 14.66 971 299 3.50 / 883.24 2 2
6 13 36.24 21 14.93 347 109 3.61 / 883.35 2 2
7 8 0.12 165 14.91 296 728 4.33 / 884.07 2 2
Average= 4.21
(KJ/cycle)

Cycle 208 GMT 14/ 4/2023 6:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 30 15.02 0 0 0.00 / 875.42 2 2
2 7 2009.00 46 14.09 2944 1908 1.91 / 877.33 2 2
3 13 1612.20 21 14.18 2479 738 2.65 / 878.07 2 2
4 13 1043.44 21 14.37 1750 528 3.17 / 878.60 2 2
5 13 468.28 21 14.65 985 303 3.48 / 878.90 2 2
6 13 22.00 21 14.94 326 102 3.58 / 879.00 2 2
7 8 0.24 165 14.92 299 736 4.32 / 879.74 2 2
Average= 4.21
(KJ/cycle)

Cycle 207 GMT 4/ 4/2023 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 15.03 0 0 0.00 / 871.12 2 2
2 7 2010.40 46 14.09 2938 1904 1.90 / 873.02 2 2
3