SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 34 | 15.06 | 554 | 284 | 0.28 / 229.69 | 4 | 16 |
2 | 3 | 967.20 | -1 | 15.43 | 0 | 0 | 0.00 / 229.69 | 4 | 16 |
3 | 7 | 2010.84 | 40 | 14.70 | 3656 | 2150 | 2.43 / 231.84 | 16 | 19 |
4 | 13 | 1445.28 | 20 | 14.79 | 2779 | 822 | 3.26 / 232.66 | 4 | 27 |
5 | 13 | 867.44 | 20 | 14.91 | 1849 | 551 | 3.81 / 233.21 | 4 | 32 |
6 | 13 | 160.36 | 20 | 15.12 | 683 | 207 | 4.01 / 233.42 | 4 | 35 |
7 | 13 | 15.32 | 20 | 15.16 | 422 | 128 | 4.14 / 233.55 | 4 | 36 |
8 | 8 | 0.56 | 265 | 15.09 | 370 | 1480 | 5.62 / 235.03 | 4 | 137 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 33 | 15.07 | 574 | 285 | 0.29 / 223.99 | 5 | 16 |
2 | 3 | 1035.68 | 1 | 15.09 | 2131 | 32 | 0.32 / 224.02 | 4 | 9 |
3 | 7 | 2010.64 | 40 | 14.70 | 3666 | 2156 | 2.47 / 226.17 | 9 | 20 |
4 | 13 | 1439.28 | 20 | 14.80 | 2755 | 815 | 3.29 / 226.99 | 4 | 28 |
5 | 13 | 856.04 | 20 | 14.91 | 1839 | 548 | 3.84 / 227.54 | 4 | 33 |
6 | 13 | 258.76 | 20 | 15.09 | 851 | 257 | 4.09 / 227.79 | 4 | 32 |
7 | 8 | 0.16 | 287 | 15.10 | 372 | 1612 | 5.71 / 229.41 | 4 | 133 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 35 | 15.07 | 549 | 290 | 0.29 / 218.43 | 4 | 16 |
2 | 3 | 927.48 | -1 | 15.44 | 0 | 0 | 0.00 / 218.43 | 4 | 16 |
3 | 7 | 2007.60 | 40 | 14.71 | 3652 | 2149 | 2.44 / 220.58 | 16 | 19 |
4 | 13 | 1432.00 | 20 | 14.80 | 2749 | 814 | 3.25 / 221.39 | 4 | 26 |
5 | 13 | 856.80 | 20 | 14.93 | 1822 | 544 | 3.80 / 221.93 | 4 | 32 |
6 | 13 | 84.20 | 20 | 15.16 | 549 | 166 | 3.96 / 222.10 | 4 | 30 |
7 | 8 | 0.00 | 287 | 15.11 | 369 | 1600 | 5.56 / 223.70 | 4 | 138 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 35 | 15.07 | 581 | 306 | 0.31 / 212.84 | 4 | 17 |
2 | 7 | 2010.80 | 40 | 14.71 | 3658 | 2152 | 2.46 / 214.99 | 4 | 18 |
3 | 13 | 1433.16 | 20 | 14.81 | 2753 | 815 | 3.27 / 215.81 | 4 | 27 |
4 | 13 | 870.32 | 20 | 14.92 | 1844 | 550 | 3.82 / 216.36 | 4 | 33 |
5 | 13 | 165.08 | 20 | 15.13 | 681 | 206 | 4.03 / 216.56 | 4 | 31 |
6 | 8 | 0.32 | 287 | 15.11 | 363 | 1574 | 5.60 / 218.14 | 4 | 144 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 34 | 15.09 | 557 | 286 | 0.29 / 207.13 | 4 | 18 |
2 | 3 | 1037.00 | 1 | 15.09 | 2119 | 32 | 0.32 / 207.16 | 4 | 8 |
3 | 7 | 2008.76 | 40 | 14.71 | 3636 | 2139 | 2.46 / 209.30 | 8 | 20 |
4 | 13 | 1437.60 | 20 | 14.81 | 2741 | 812 | 3.27 / 210.11 | 4 | 26 |
5 | 13 | 972.04 | 20 | 14.89 | 2014 | 600 | 3.87 / 210.71 | 4 | 31 |
6 | 13 | 233.00 | 20 | 15.12 | 796 | 241 | 4.11 / 210.95 | 4 | 35 |
7 | 8 | 0.24 | 289 | 15.12 | 362 | 1582 | 5.69 / 212.53 | 4 | 143 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 34 | 15.09 | 539 | 277 | 0.28 / 201.51 | 5 | 15 |
2 | 7 | 2014.36 | 40 | 14.72 | 3639 | 2143 | 2.42 / 203.65 | 15 | 19 |
3 | 13 | 1447.56 | 20 | 14.81 | 2754 | 816 | 3.23 / 204.47 | 4 | 26 |
4 | 13 | 964.04 | 20 | 14.91 | 1987 | 593 | 3.83 / 205.06 | 4 | 33 |
5 | 13 | 215.60 | 20 | 15.13 | 763 | 231 | 4.06 / 205.29 | 4 | 33 |
6 | 8 | 0.32 | 289 | 15.13 | 354 | 1548 | 5.61 / 206.84 | 4 | 137 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 33 | 15.10 | 543 | 271 | 0.27 / 195.90 | 4 | 17 |
2 | 3 | 1028.52 | 1 | 15.09 | 2111 | 32 | 0.30 / 195.93 | 4 | 5 |
3 | 7 | 2012.60 | 41 | 14.71 | 3646 | 2199 | 2.50 / 198.13 | 5 | 20 |
4 | 13 | 1344.36 | 20 | 14.83 | 2596 | 770 | 3.27 / 198.90 | 4 | 27 |
5 | 13 | 890.76 | 20 | 14.92 | 1868 | 557 | 3.83 / 199.46 | 4 | 33 |
6 | 13 | 165.16 | 20 | 15.14 | 675 | 204 | 4.03 / 199.66 | 4 | 33 |
7 | 8 | 0.12 | 289 | 15.12 | 360 | 1573 | 5.61 / 201.24 | 4 | 145 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 34 | 15.08 | 528 | 271 | 0.27 / 190.32 | 5 | 17 |
2 | 7 | 2007.64 | 40 | 14.72 | 3640 | 2143 | 2.41 / 192.46 | 17 | 18 |
3 | 13 | 1432.04 | 20 | 14.82 | 2728 | 809 | 3.22 / 193.27 | 4 | 26 |
4 | 13 | 862.92 | 20 | 14.94 | 1819 | 544 | 3.77 / 193.82 | 4 | 32 |
5 | 13 | 164.16 | 20 | 15.15 | 677 | 205 | 3.97 / 194.02 | 4 | 31 |
6 | 8 | 0.64 | 289 | 15.13 | 368 | 1609 | 5.58 / 195.63 | 4 | 130 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 34 | 15.09 | 553 | 284 | 0.28 / 184.79 | 4 | 15 |
2 | 7 | 2011.52 | 40 | 14.72 | 3643 | 2145 | 2.43 / 186.93 | 15 | 19 |
3 | 13 | 1436.08 | 20 | 14.82 | 2734 | 810 | 3.24 / 187.74 | 4 | 26 |
4 | 13 | 855.64 | 20 | 14.94 | 1804 | 539 | 3.78 / 188.28 | 4 | 32 |
5 | 13 | 163.48 | 20 | 15.15 | 673 | 204 | 3.98 / 188.48 | 4 | 35 |
6 | 8 | 0.08 | 289 | 15.13 | 358 | 1565 | 5.55 / 190.05 | 4 | 134 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 33 | 15.09 | 578 | 288 | 0.29 / 179.23 | 4 | 15 |
2 | 3 | 1038.80 | 1 | 15.10 | 2115 | 32 | 0.32 / 179.26 | 4 | 6 |
3 | 7 | 2010.84 | 41 | 14.72 | 3621 | 2185 | 2.51 / 181.45 | 6 | 20 |
4 | 13 | 1404.08 | 20 | 14.83 | 2677 | 794 | 3.30 / 182.24 | 4 | 27 |
5 | 13 | 829.80 | 20 | 14.95 | 1767 | 528 | 3.83 / 182.77 | 4 | 34 |
6 | 13 | 123.00 | 20 | 15.16 | 591 | 179 | 4.01 / 182.95 | 4 | 35 |
7 | 8 | 0.20 | 287 | 15.13 | 357 | 1550 | 5.56 / 184.50 | 4 | 130 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 33 | 15.10 | 535 | 267 | 0.27 / 173.74 | 5 | 15 |
2 | 7 | 2009.44 | 40 | 14.72 | 3622 | 2133 | 2.40 / 175.87 | 15 | 19 |
3 | 13 | 1421.84 | 20 | 14.83 | 2704 | 802 | 3.20 / 176.67 | 4 | 27 |
4 | 13 | 839.16 | 20 | 14.95 | 1796 | 537 | 3.74 / 177.21 | 4 | 34 |
5 | 13 | 70.60 | 20 | 15.18 | 512 | 155 | 3.89 / 177.36 | 4 | 33 |
6 | 8 | 0.16 | 287 | 15.14 | 364 | 1582 | 5.48 / 178.95 | 4 | 136 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 35 | 15.09 | 531 | 280 | 0.28 / 168.29 | 5 | 17 |
2 | 3 | 948.60 | -1 | 15.46 | 0 | 0 | 0.00 / 168.29 | 5 | 17 |
3 | 7 | 2005.00 | 40 | 14.73 | 3618 | 2132 | 2.41 / 170.42 | 17 | 19 |
4 | 13 | 1435.24 | 20 | 14.83 | 2737 | 812 | 3.22 / 171.23 | 4 | 27 |
5 | 13 | 847.88 | 20 | 14.96 | 1788 | 535 | 3.76 / 171.77 | 4 | 32 |
6 | 13 | 80.16 | 20 | 15.19 | 519 | 158 | 3.92 / 171.92 | 4 | 31 |
7 | 8 | 0.36 | 287 | 15.14 | 356 | 1547 | 5.46 / 173.47 | 4 | 146 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 33 | 15.10 | 565 | 282 | 0.28 / 162.64 | 4 | 16 |
2 | 10 | 1010.40 | 3 | 15.04 | 2058 | 93 | 0.37 / 162.73 | 4 | 18 |
3 | 7 | 2004.44 | 40 | 14.74 | 3630 | 2140 | 2.51 / 164.87 | 18 | 20 |
4 | 13 | 1428.40 | 20 | 14.83 | 2716 | 806 | 3.32 / 165.68 | 4 | 25 |
5 | 13 | 860.16 | 20 | 14.96 | 1802 | 539 | 3.86 / 166.21 | 4 | 33 |
6 | 13 | 258.68 | 20 | 15.12 | 832 | 252 | 4.11 / 166.47 | 4 | 34 |
7 | 8 | -0.16 | 289 | 15.14 | 352 | 1540 | 5.65 / 168.01 | 4 | 138 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 33 | 15.10 | 549 | 274 | 0.27 / 157.14 | 4 | 19 |
2 | 7 | 2004.52 | 40 | 14.74 | 3632 | 2141 | 2.41 / 159.28 | 19 | 19 |
3 | 13 | 1418.08 | 20 | 14.85 | 2703 | 803 | 3.22 / 160.09 | 4 | 27 |
4 | 13 | 840.24 | 20 | 14.96 | 1782 | 533 | 3.75 / 160.62 | 4 | 31 |
5 | 13 | 134.08 | 20 | 15.17 | 620 | 188 | 3.94 / 160.81 | 4 | 32 |
6 | 8 | 0.08 | 287 | 15.15 | 356 | 1548 | 5.49 / 162.36 | 4 | 136 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 32 | 15.11 | 544 | 263 | 0.26 / 151.49 | 4 | 18 |
2 | 3 | 1030.68 | 1 | 15.11 | 2099 | 32 | 0.29 / 151.52 | 4 | 5 |
3 | 7 | 2006.56 | 40 | 14.74 | 3637 | 2144 | 2.44 / 153.67 | 5 | 19 |
4 | 13 | 1523.32 | 20 | 14.83 | 2874 | 852 | 3.29 / 154.52 | 4 | 26 |
5 | 13 | 837.48 | 20 | 14.97 | 1780 | 533 | 3.82 / 155.05 | 4 | 33 |
6 | 13 | 254.44 | 20 | 15.13 | 825 | 250 | 4.07 / 155.30 | 4 | 35 |
7 | 8 | 0.52 | 289 | 15.14 | 358 | 1566 | 5.64 / 156.87 | 4 | 140 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 32 | 15.10 | 532 | 257 | 0.26 / 145.96 | 4 | 20 |
2 | 7 | 2005.72 | 40 | 14.74 | 3622 | 2136 | 2.39 / 148.10 | 20 | 18 |
3 | 13 | 1429.16 | 20 | 14.85 | 2722 | 808 | 3.20 / 148.90 | 4 | 26 |
4 | 13 | 950.68 | 20 | 14.94 | 1968 | 588 | 3.79 / 149.49 | 4 | 33 |
5 | 13 | 143.52 | 20 | 15.17 | 640 | 194 | 3.98 / 149.69 | 4 | 35 |
6 | 8 | -0.16 | 289 | 15.15 | 352 | 1541 | 5.52 / 151.23 | 4 | 133 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 32 | 15.10 | 554 | 268 | 0.27 / 140.45 | 4 | 19 |
2 | 7 | 2003.64 | 40 | 14.75 | 3627 | 2140 | 2.41 / 142.59 | 19 | 19 |
3 | 13 | 1432.72 | 20 | 14.86 | 2729 | 811 | 3.22 / 143.40 | 4 | 26 |
4 | 13 | 857.16 | 20 | 14.96 | 1821 | 545 | 3.76 / 143.94 | 4 | 33 |
5 | 13 | 157.64 | 20 | 15.16 | 666 | 202 | 3.97 / 144.15 | 4 | 35 |
6 | 8 | 0.12 | 289 | 15.14 | 356 | 1558 | 5.52 / 145.70 | 4 | 133 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 34 | 15.10 | 544 | 279 | 0.28 / 134.96 | 4 | 19 |
2 | 3 | 947.80 | -1 | 15.47 | 0 | 0 | 0.00 / 134.96 | 4 | 19 |
3 | 7 | 2010.92 | 40 | 14.74 | 3635 | 2143 | 2.42 / 137.10 | 19 | 20 |
4 | 13 | 1332.08 | 20 | 14.87 | 2575 | 766 | 3.19 / 137.87 | 4 | 27 |
5 | 13 | 872.08 | 20 | 14.96 | 1841 | 551 | 3.74 / 138.42 | 4 | 32 |
6 | 13 | 165.80 | 20 | 15.16 | 675 | 205 | 3.94 / 138.62 | 4 | 36 |
7 | 8 | 0.44 | 289 | 15.15 | 356 | 1559 | 5.50 / 140.18 | 4 | 143 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 32 | 15.10 | 578 | 279 | 0.28 / 129.40 | 4 | 19 |
2 | 10 | 1024.44 | 3 | 15.03 | 2054 | 93 | 0.37 / 129.49 | 4 | 20 |
3 | 7 | 2003.60 | 40 | 14.75 | 3630 | 2142 | 2.51 / 131.63 | 20 | 20 |
4 | 13 | 1430.12 | 20 | 14.86 | 2704 | 804 | 3.32 / 132.43 | 4 | 27 |
5 | 13 | 753.28 | 20 | 15.00 | 1640 | 492 | 3.81 / 132.93 | 4 | 33 |
6 | 13 | 181.72 | 20 | 15.16 | 692 | 210 | 4.02 / 133.14 | 4 | 36 |
7 | 8 | -0.24 | 289 | 15.15 | 352 | 1541 | 5.56 / 134.68 | 4 | 133 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 33 | 15.11 | 555 | 277 | 0.28 / 123.77 | 4 | 20 |
2 | 3 | 952.56 | -1 | 15.47 | 0 | 0 | 0.00 / 123.77 | 4 | 20 |
3 | 7 | 2005.80 | 41 | 14.75 | 3623 | 2191 | 2.47 / 125.96 | 20 | 19 |
4 | 13 | 1424.48 | 20 | 14.86 | 2718 | 808 | 3.28 / 126.76 | 4 | 27 |
5 | 13 | 833.28 | 20 | 14.98 | 1767 | 529 | 3.80 / 127.29 | 4 | 33 |
6 | 13 | 144.24 | 20 | 15.17 | 647 | 196 | 4.00 / 127.49 | 4 | 36 |
7 | 8 | -0.12 | 291 | 15.15 | 369 | 1627 | 5.63 / 129.12 | 4 | 148 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 32 | 15.12 | 574 | 278 | 0.28 / 118.20 | 4 | 20 |
2 | 3 | 1034.32 | 1 | 15.12 | 2121 | 32 | 0.31 / 118.23 | 4 | 6 |
3 | 7 | 2008.04 | 40 | 14.76 | 3625 | 2140 | 2.45 / 120.37 | 6 | 19 |
4 | 13 | 1415.72 | 20 | 14.86 | 2707 | 805 | 3.25 / 121.18 | 4 | 26 |
5 | 13 | 842.68 | 20 | 14.98 | 1785 | 535 | 3.79 / 121.71 | 4 | 32 |
6 | 13 | 155.92 | 20 | 15.17 | 662 | 201 | 3.99 / 121.91 | 4 | 36 |
7 | 8 | 0.32 | 289 | 15.15 | 360 | 1576 | 5.57 / 123.49 | 4 | 132 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 33 | 15.12 | 553 | 276 | 0.28 / 112.71 | 4 | 19 |
2 | 7 | 2004.44 | 40 | 14.75 | 3629 | 2141 | 2.42 / 114.85 | 19 | 19 |
3 | 13 | 1415.88 | 20 | 14.87 | 2700 | 803 | 3.22 / 115.65 | 4 | 26 |
4 | 13 | 839.12 | 20 | 14.98 | 1787 | 535 | 3.76 / 116.18 | 4 | 33 |
5 | 13 | 140.76 | 20 | 15.18 | 631 | 192 | 3.95 / 116.38 | 4 | 35 |
6 | 8 | 0.00 | 289 | 15.16 | 353 | 1547 | 5.49 / 117.92 | 4 | 137 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 33 | 15.12 | 538 | 268 | 0.27 / 107.28 | 4 | 19 |
2 | 7 | 2012.04 | 41 | 14.75 | 3638 | 2200 | 2.47 / 109.48 | 19 | 20 |
3 | 13 | 1326.84 | 20 | 14.89 | 2555 | 761 | 3.23 / 110.24 | 4 | 27 |
4 | 13 | 763.60 | 20 | 15.00 | 1670 | 501 | 3.73 / 110.74 | 4 | 33 |
5 | 13 | 106.04 | 20 | 15.20 | 567 | 172 | 3.90 / 110.91 | 4 | 35 |
6 | 8 | 0.04 | 287 | 15.16 | 349 | 1518 | 5.42 / 112.43 | 4 | 133 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 33 | 15.12 | 561 | 280 | 0.28 / 101.75 | 4 | 19 |
2 | 7 | 2009.60 | 40 | 14.77 | 3626 | 2142 | 2.42 / 103.89 | 4 | 19 |
3 | 13 | 1436.36 | 20 | 14.88 | 2724 | 811 | 3.23 / 104.70 | 4 | 26 |
4 | 13 | 845.56 | 20 | 14.99 | 1793 | 538 | 3.77 / 105.24 | 4 | 32 |
5 | 13 | 242.28 | 20 | 15.16 | 796 | 241 | 4.01 / 105.48 | 4 | 35 |
6 | 8 | -0.12 | 289 | 15.17 | 348 | 1526 | 5.54 / 107.01 | 4 | 133 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 33 | 15.13 | 544 | 272 | 0.27 / 96.21 | 4 | 18 |
2 | 7 | 2003.04 | 40 | 14.77 | 3626 | 2142 | 2.41 / 98.35 | 18 | 20 |
3 | 13 | 1417.96 | 20 | 14.88 | 2701 | 804 | 3.22 / 99.15 | 4 | 27 |
4 | 13 | 854.60 | 20 | 14.99 | 1817 | 545 | 3.76 / 99.70 | 4 | 32 |
5 | 13 | 155.28 | 20 | 15.19 | 661 | 201 | 3.96 / 99.90 | 4 | 35 |
6 | 8 | 0.12 | 289 | 15.16 | 359 | 1573 | 5.54 / 101.47 | 4 | 136 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 33 | 15.12 | 555 | 277 | 0.28 / 90.67 | 4 | 18 |
2 | 7 | 2005.88 | 40 | 14.77 | 3639 | 2150 | 2.43 / 92.82 | 18 | 19 |
3 | 13 | 1435.76 | 20 | 14.88 | 2739 | 815 | 3.24 / 93.64 | 4 | 26 |
4 | 13 | 851.08 | 20 | 14.99 | 1809 | 542 | 3.78 / 94.18 | 4 | 32 |
5 | 13 | 156.92 | 20 | 15.19 | 653 | 198 | 3.98 / 94.38 | 4 | 33 |
6 | 8 | -0.04 | 287 | 15.17 | 358 | 1559 | 5.54 / 95.93 | 4 | 135 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 33 | 15.13 | 563 | 281 | 0.28 / 85.09 | 4 | 18 |
2 | 7 | 2003.84 | 40 | 14.77 | 3639 | 2150 | 2.43 / 87.24 | 4 | 19 |
3 | 13 | 1407.16 | 20 | 14.89 | 2699 | 804 | 3.23 / 88.04 | 4 | 26 |
4 | 13 | 821.52 | 20 | 15.01 | 1768 | 531 | 3.77 / 88.57 | 4 | 33 |
5 | 13 | 215.68 | 20 | 15.17 | 770 | 234 | 4.00 / 88.81 | 4 | 34 |
6 | 8 | 0.08 | 287 | 15.17 | 364 | 1585 | 5.58 / 90.39 | 4 | 131 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 33 | 15.12 | 559 | 279 | 0.28 / 79.49 | 4 | 18 |
2 | 7 | 2012.56 | 40 | 14.78 | 3644 | 2154 | 2.43 / 81.65 | 18 | 19 |
3 | 13 | 1328.84 | 20 | 14.91 | 2559 | 763 | 3.20 / 82.41 | 4 | 27 |
4 | 13 | 875.08 | 20 | 14.99 | 1846 | 553 | 3.75 / 82.96 | 4 | 31 |
5 | 13 | 256.76 | 20 | 15.16 | 845 | 256 | 4.01 / 83.22 | 4 | 35 |
6 | 8 | 0.32 | 287 | 15.17 | 365 | 1589 | 5.60 / 84.81 | 4 | 136 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.84 | 33 | 15.13 | 565 | 282 | 0.28 / 73.86 | 4 | 18 |
2 | 3 | 1018.76 | 1 | 15.15 | 2077 | 31 | 0.31 / 73.89 | 4 | 5 |
3 | 7 | 2004.28 | 41 | 14.78 | 3635 | 2203 | 2.52 / 76.10 | 5 | 18 |
4 | 13 | 1430.60 | 20 | 14.89 | 2739 | 816 | 3.33 / 76.91 | 4 | 27 |
5 | 13 | 750.72 | 20 | 15.02 | 1645 | 494 | 3.83 / 77.41 | 4 | 33 |
6 | 13 | 162.96 | 20 | 15.19 | 687 | 209 | 4.03 / 77.61 | 4 | 36 |
7 | 8 | 0.12 | 289 | 15.17 | 365 | 1600 | 5.64 / 79.21 | 4 | 137 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 33 | 15.13 | 561 | 280 | 0.28 / 68.37 | 4 | 18 |
2 | 7 | 2014.44 | 40 | 14.79 | 3643 | 2155 | 2.44 / 70.52 | 18 | 19 |
3 | 13 | 1334.32 | 20 | 14.92 | 2556 | 763 | 3.20 / 71.29 | 4 | 26 |
4 | 13 | 790.32 | 20 | 15.02 | 1714 | 515 | 3.71 / 71.80 | 4 | 33 |
5 | 13 | 126.88 | 20 | 15.20 | 620 | 188 | 3.90 / 71.99 | 4 | 36 |
6 | 8 | 0.44 | 287 | 15.17 | 365 | 1589 | 5.49 / 73.58 | 4 | 135 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 33 | 15.13 | 565 | 282 | 0.28 / 62.83 | 4 | 18 |
2 | 7 | 2005.60 | 40 | 14.80 | 3643 | 2157 | 2.44 / 64.98 | 18 | 20 |
3 | 13 | 1422.04 | 20 | 14.90 | 2717 | 810 | 3.25 / 65.79 | 4 | 26 |
4 | 13 | 743.76 | 20 | 15.04 | 1636 | 492 | 3.74 / 66.28 | 4 | 33 |
5 | 13 | 164.40 | 20 | 15.20 | 670 | 204 | 3.94 / 66.49 | 4 | 36 |
6 | 8 | -0.20 | 289 | 15.18 | 365 | 1601 | 5.55 / 68.09 | 4 | 132 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 33 | 15.14 | 558 | 279 | 0.28 / 57.23 | 4 | 16 |
2 | 7 | 2003.40 | 40 | 14.79 | 3627 | 2146 | 2.42 / 59.38 | 16 | 20 |
3 | 13 | 1431.24 | 20 | 14.90 | 2739 | 816 | 3.24 / 60.20 | 4 | 26 |
4 | 13 | 835.00 | 20 | 15.01 | 1784 | 536 | 3.78 / 60.73 | 4 | 33 |
5 | 13 | 152.20 | 20 | 15.20 | 662 | 201 | 3.98 / 60.93 | 4 | 38 |
6 | 8 | 0.40 | 291 | 15.17 | 365 | 1611 | 5.59 / 62.54 | 4 | 138 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 33 | 15.15 | 546 | 273 | 0.27 / 51.70 | 4 | 15 |
2 | 7 | 2005.52 | 40 | 14.80 | 3628 | 2148 | 2.42 / 53.85 | 15 | 18 |
3 | 13 | 1401.72 | 20 | 14.91 | 2680 | 799 | 3.22 / 54.64 | 4 | 27 |
4 | 13 | 811.52 | 20 | 15.03 | 1727 | 519 | 3.74 / 55.16 | 4 | 33 |
5 | 13 | 116.60 | 20 | 15.22 | 602 | 183 | 3.92 / 55.35 | 4 | 35 |
6 | 8 | 0.28 | 287 | 15.18 | 369 | 1608 | 5.53 / 56.95 | 4 | 134 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 33 | 15.15 | 551 | 275 | 0.28 / 46.19 | 5 | 14 |
2 | 7 | 2013.00 | 41 | 14.80 | 3653 | 2217 | 2.49 / 48.41 | 4 | 20 |
3 | 13 | 1326.48 | 20 | 14.93 | 2575 | 769 | 3.26 / 49.18 | 4 | 27 |
4 | 13 | 776.20 | 20 | 15.04 | 1686 | 507 | 3.77 / 49.69 | 4 | 31 |
5 | 13 | 96.48 | 20 | 15.23 | 557 | 170 | 3.94 / 49.86 | 4 | 32 |
6 | 8 | -0.12 | 287 | 15.19 | 360 | 1569 | 5.51 / 51.42 | 4 | 139 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 33 | 15.15 | 544 | 272 | 0.27 / 40.71 | 5 | 14 |
2 | 7 | 2005.32 | 40 | 14.82 | 3620 | 2146 | 2.42 / 42.85 | 4 | 18 |
3 | 13 | 1329.48 | 20 | 14.94 | 2568 | 767 | 3.19 / 43.62 | 4 | 27 |
4 | 13 | 878.32 | 20 | 15.01 | 1848 | 555 | 3.74 / 44.17 | 4 | 32 |
5 | 13 | 97.00 | 20 | 15.24 | 551 | 168 | 3.91 / 44.34 | 4 | 31 |
6 | 8 | 0.08 | 287 | 15.20 | 361 | 1575 | 5.48 / 45.92 | 4 | 142 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 33 | 15.14 | 553 | 276 | 0.28 / 35.19 | 4 | 15 |
2 | 7 | 2007.24 | 40 | 14.81 | 3633 | 2152 | 2.43 / 37.35 | 15 | 19 |
3 | 13 | 1419.76 | 20 | 14.92 | 2718 | 811 | 3.24 / 38.16 | 4 | 26 |
4 | 13 | 837.04 | 20 | 15.02 | 1787 | 537 | 3.78 / 38.69 | 4 | 33 |
5 | 13 | 75.80 | 20 | 15.25 | 506 | 154 | 3.93 / 38.85 | 4 | 31 |
6 | 8 | 0.12 | 285 | 15.20 | 366 | 1586 | 5.52 / 40.43 | 4 | 139 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 32 | 15.16 | 550 | 267 | 0.27 / 29.59 | 5 | 15 |
2 | 10 | 1013.20 | 3 | 15.11 | 2047 | 93 | 0.36 / 29.69 | 4 | 19 |
3 | 3 | 954.36 | -1 | 15.51 | 0 | 0 | 0.09 / 29.69 | 4 | 19 |
4 | 7 | 2007.28 | 40 | 14.81 | 3640 | 2156 | 2.52 / 31.84 | 19 | 20 |
5 | 13 | 1309.04 | 20 | 14.94 | 2537 | 758 | 3.27 / 32.60 | 4 | 28 |
6 | 13 | 762.24 | 20 | 15.04 | 1663 | 500 | 3.77 / 33.10 | 4 | 33 |
7 | 13 | 170.16 | 20 | 15.20 | 689 | 209 | 3.98 / 33.31 | 4 | 35 |
8 | 8 | 0.08 | 287 | 15.19 | 369 | 1609 | 5.59 / 34.92 | 4 | 148 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 32 | 15.15 | 555 | 269 | 0.27 / 24.12 | 4 | 15 |
2 | 3 | 1030.44 | 1 | 15.16 | 2111 | 32 | 0.30 / 24.16 | 4 | 7 |
3 | 7 | 2004.56 | 40 | 14.82 | 3636 | 2155 | 2.46 / 26.31 | 7 | 20 |
4 | 13 | 1315.12 | 20 | 14.95 | 2552 | 763 | 3.22 / 27.07 | 4 | 27 |
5 | 13 | 744.44 | 20 | 15.05 | 1640 | 494 | 3.71 / 27.57 | 4 | 32 |
6 | 13 | 77.64 | 20 | 15.25 | 522 | 159 | 3.87 / 27.73 | 4 | 32 |
7 | 8 | 0.16 | 285 | 15.20 | 369 | 1599 | 5.47 / 29.33 | 4 | 139 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 31 | 15.16 | 542 | 255 | 0.25 / 18.58 | 5 | 13 |
2 | 3 | 1034.48 | 1 | 15.18 | 2090 | 32 | 0.29 / 18.61 | 4 | 9 |
3 | 7 | 2012.92 | 40 | 14.83 | 3635 | 2156 | 2.44 / 20.77 | 9 | 19 |
4 | 13 | 1429.04 | 20 | 14.92 | 2730 | 815 | 3.26 / 21.58 | 4 | 27 |
5 | 13 | 736.60 | 20 | 15.06 | 1624 | 489 | 3.75 / 22.07 | 4 | 33 |
6 | 13 | 151.52 | 20 | 15.22 | 645 | 196 | 3.94 / 22.27 | 4 | 35 |
7 | 8 | 0.00 | 285 | 15.19 | 367 | 1589 | 5.53 / 23.86 | 4 | 134 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 32 | 15.17 | 533 | 259 | 0.26 / 13.78 | 4 | 14 |
2 | 7 | 1506.28 | 40 | 14.98 | 2835 | 1699 | 1.96 / 15.48 | 4 | 23 |
3 | 13 | 1210.84 | 20 | 15.02 | 2372 | 713 | 2.67 / 16.20 | 4 | 27 |
4 | 13 | 644.32 | 20 | 15.11 | 1477 | 446 | 3.12 / 16.64 | 4 | 33 |
5 | 13 | 33.28 | 20 | 15.28 | 442 | 135 | 3.25 / 16.78 | 4 | 32 |
6 | 8 | 0.08 | 280 | 15.22 | 363 | 1547 | 4.80 / 18.32 | 4 | 142 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 31 | 15.22 | 555 | 262 | 0.26 / 8.90 | 4 | 13 |
2 | 7 | 1519.76 | 40 | 14.99 | 2843 | 1705 | 1.97 / 10.60 | 13 | 22 |
3 | 13 | 1310.32 | 20 | 15.00 | 2517 | 755 | 2.72 / 11.36 | 4 | 27 |
4 | 13 | 716.72 | 20 | 15.10 | 1584 | 478 | 3.20 / 11.83 | 4 | 32 |
5 | 13 | 52.36 | 20 | 15.27 | 470 | 144 | 3.34 / 11.98 | 4 | 32 |
6 | 8 | 0.08 | 280 | 15.22 | 363 | 1547 | 4.89 / 13.53 | 4 | 148 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 31 | 15.21 | 540 | 255 | 0.25 / 5.45 | 4 | 12 |
2 | 7 | 1154.72 | 40 | 15.11 | 2255 | 1363 | 1.62 / 6.81 | 7 | 28 |
3 | 13 | 253.44 | 20 | 15.30 | 810 | 248 | 1.87 / 7.06 | 4 | 33 |
4 | 8 | 0.16 | 285 | 15.29 | 362 | 1577 | 3.44 / 8.63 | 4 | 145 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 31 | 15.35 | 506 | 241 | 0.24 / 2.32 | 5 | 10 |
2 | 7 | 1011.40 | 40 | 15.11 | 2033 | 1229 | 1.47 / 3.55 | 10 | 28 |
3 | 13 | 56.96 | 20 | 15.34 | 463 | 142 | 1.61 / 3.69 | 4 | 30 |
4 | 8 | 0.08 | 276 | 15.28 | 355 | 1497 | 3.11 / 5.19 | 4 | 133 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 165.20 | 30 | 15.54 | 580 | 270 | 0.27 / 0.27 | 5 | 7 |
2 | 7 | 178.56 | 40 | 15.51 | 594 | 369 | 0.64 / 0.64 | 7 | 9 |
3 | 13 | 40.36 | 20 | 15.51 | 380 | 118 | 0.76 / 0.76 | 5 | 12 |
4 | 8 | 0.24 | 276 | 15.45 | 311 | 1326 | 2.08 / 2.08 | 5 | 154 |
Average= | 2.08 (KJ/cycle) |