SIO Argo Site:
Pump Diagnostics Page   



Serial= 7795 WMO= 1902523

Return

←PreviousNext→

Cycle 42 GMT 29/ 3/2025 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 20 15.04 535 161 0.16 / 211.98 5 26
2 10 1037.88 3 14.93 2037 91 0.25 / 212.07 5 19
3 7 2009.20 40 14.65 3543 2076 2.33 / 214.15 19 19
4 13 1299.24 20 14.80 2453 726 3.05 / 214.87 5 27
5 13 620.92 20 14.98 1367 410 3.46 / 215.28 5 34
6 13 83.52 20 15.14 494 150 3.61 / 215.43 5 43
7 8 0.00 400 15.06 347 2090 5.70 / 217.52 5 117
Average= 5.06
(KJ/cycle)

Cycle 41 GMT 18/ 3/2025 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 33 15.02 543 269 0.27 / 206.87 5 26
2 3 677.04 -5 15.42 0 0 0.00 / 206.87 5 26
3 7 2003.56 41 14.65 3550 2132 2.40 / 209.00 26 19
4 13 1289.24 20 14.82 2367 702 3.10 / 209.70 5 27
5 13 608.52 20 14.99 1333 400 3.50 / 210.10 5 36
6 13 69.84 20 15.15 478 145 3.65 / 210.25 5 42
7 8 0.08 300 15.09 347 1571 5.22 / 211.82 5 131
Average= 5.04
(KJ/cycle)

Cycle 40 GMT 8/ 3/2025 13:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 26 15.04 499 195 0.20 / 201.27 5 7
2 10 1022.16 6 14.90 2046 183 0.38 / 201.45 5 23
3 3 1062.84 2 15.02 2036 61 0.44 / 201.51 5 12
4 7 2003.92 40 14.66 3528 2069 2.51 / 203.58 12 19
5 13 1296.76 20 14.81 2443 724 3.23 / 204.30 5 26
6 13 710.68 20 14.95 1495 447 3.68 / 204.75 5 34
7 13 61.60 20 15.15 452 137 3.82 / 204.89 5 41
8 8 0.12 340 15.09 334 1714 5.53 / 206.60 5 141
Average= 5.04
(KJ/cycle)

Cycle 39 GMT 26/ 2/2025 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 24 15.05 507 183 0.18 / 195.59 5 23
2 10 1004.48 3 14.96 1940 87 0.27 / 195.68 5 17
3 7 2009.88 40 14.67 3538 2076 2.35 / 197.75 17 18
4 13 1402.80 20 14.79 2621 775 3.12 / 198.53 5 26
5 13 797.56 20 14.93 1652 493 3.61 / 199.02 5 33
6 13 96.80 20 15.15 522 158 3.77 / 199.18 5 40
7 8 -0.04 374 15.09 335 1891 5.66 / 201.07 5 145
Average= 5.03
(KJ/cycle)

Cycle 38 GMT 16/ 2/2025 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 24 15.06 522 189 0.19 / 189.95 5 24
2 7 2003.20 41 14.67 3543 2131 2.32 / 192.08 24 18
3 13 1394.60 20 14.80 2596 768 3.09 / 192.85 5 25
4 13 888.72 20 14.91 1794 535 3.62 / 193.38 5 32
5 13 120.76 20 15.14 560 170 3.79 / 193.55 5 40
6 8 0.12 377 15.10 326 1856 5.65 / 195.41 5 132
Average= 5.01
(KJ/cycle)

Cycle 37 GMT 5/ 2/2025 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 23 15.06 539 187 0.19 / 184.72 5 25
2 10 1013.28 3 14.95 2005 90 0.28 / 184.80 5 18
3 7 2013.00 40 14.68 3506 2059 2.34 / 186.86 18 19
4 13 1308.52 20 14.83 2419 717 3.05 / 187.58 5 26
5 13 825.80 20 14.93 1694 506 3.56 / 188.09 5 32
6 13 117.36 20 15.15 552 167 3.73 / 188.25 5 40
7 8 0.20 300 15.11 332 1505 5.23 / 189.76 5 131
Average= 4.99
(KJ/cycle)

Cycle 36 GMT 26/ 1/2025 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 22 15.05 534 177 0.18 / 179.43 5 28
2 7 2005.52 40 14.67 3545 2080 2.26 / 181.51 28 18
3 13 1293.96 20 14.83 2421 718 2.98 / 182.22 5 27
4 13 718.60 20 14.97 1494 447 3.42 / 182.67 5 33
5 13 133.80 20 15.14 568 172 3.59 / 182.84 5 40
6 8 0.24 334 15.10 334 1684 5.28 / 184.53 5 141
Average= 4.99
(KJ/cycle)

Cycle 35 GMT 16/ 1/2025 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 24 15.04 520 188 0.19 / 174.07 5 29
2 3 958.76 -1 15.43 0 0 0.00 / 174.07 5 29
3 7 2007.40 40 14.67 3524 2068 2.26 / 176.14 29 18
4 13 1417.24 20 14.80 2589 766 3.02 / 176.91 5 26
5 13 706.84 20 14.97 1493 447 3.47 / 177.35 5 36
6 13 116.80 20 15.15 547 166 3.63 / 177.52 5 43
7 8 0.04 334 15.10 343 1730 5.36 / 179.25 5 130
Average= 4.98
(KJ/cycle)

Cycle 34 GMT 5/ 1/2025 22:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 23 15.06 537 186 0.19 / 168.44 5 28
2 3 1026.76 1 15.05 2026 30 0.22 / 168.47 5 5
3 7 2006.44 40 14.67 3544 2080 2.30 / 170.55 5 19
4 13 1305.16 20 14.83 2423 719 3.01 / 171.27 5 27
5 13 722.84 20 14.97 1509 452 3.47 / 171.72 5 32
6 13 123.12 20 15.14 572 173 3.64 / 171.89 5 42
7 8 -0.12 391 15.09 338 1994 5.63 / 173.88 5 130
Average= 4.97
(KJ/cycle)

Cycle 33 GMT 26/12/2024 16: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 22 15.06 511 169 0.17 / 163.14 5 28
2 3 1018.44 1 15.08 1996 30 0.20 / 163.17 5 5
3 7 2003.16 40 14.68 3531 2073 2.27 / 165.24 5 19
4 13 1311.88 20 14.83 2427 720 2.99 / 165.96 5 27
5 13 718.48 20 14.97 1513 453 3.45 / 166.42 5 34
6 13 126.44 20 15.14 574 174 3.62 / 166.59 5 42
7 8 0.32 325 15.11 338 1660 5.28 / 168.25 5 135
Average= 4.95
(KJ/cycle)

Cycle 32 GMT 16/12/2024 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 22 15.05 537 178 0.18 / 157.86 5 30
2 7 2004.52 40 14.67 3514 2062 2.24 / 159.92 30 19
3 13 1290.08 20 14.84 2411 716 2.96 / 160.64 5 28
4 13 592.44 20 15.01 1303 391 3.35 / 161.03 5 34
5 13 59.76 20 15.17 451 137 3.48 / 161.16 5 41
6 8 -0.24 353 15.10 339 1807 5.29 / 162.97 5 154
Average= 4.94
(KJ/cycle)

Cycle 31 GMT 6/12/2024 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 24 15.06 539 195 0.19 / 152.39 5 33
2 3 964.64 -1 15.45 0 0 0.00 / 152.39 5 33
3 7 2004.96 40 14.68 3527 2071 2.27 / 154.46 33 18
4 13 1293.12 20 14.85 2400 713 2.98 / 155.17 5 28
5 13 709.84 20 14.98 1485 445 3.42 / 155.62 5 36
6 13 109.08 20 15.15 546 165 3.59 / 155.78 5 43
7 8 0.08 372 15.10 338 1899 5.49 / 157.68 5 140
Average= 4.93
(KJ/cycle)

Cycle 30 GMT 25/11/2024 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 24 15.08 534 193 0.19 / 147.23 5 28
2 7 2002.72 40 14.68 3533 2075 2.27 / 149.30 28 22
3 13 1202.00 20 14.86 2286 679 2.95 / 149.98 5 29
4 13 651.36 20 14.99 1410 423 3.37 / 150.41 5 33
5 13 88.48 20 15.16 512 155 3.53 / 150.56 5 43
6 8 0.00 313 15.12 345 1633 5.16 / 152.19 5 131
Average= 4.91
(KJ/cycle)

Cycle 29 GMT 15/11/2024 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 24 15.08 539 195 0.20 / 142.18 5 26
2 7 2008.12 40 14.69 3534 2077 2.27 / 144.25 26 19
3 13 1291.68 20 14.85 2394 711 2.98 / 144.96 5 28
4 13 707.08 20 14.99 1493 448 3.43 / 145.41 5 31
5 13 61.20 20 15.19 460 140 3.57 / 145.55 5 40
6 8 0.08 291 15.13 337 1484 5.05 / 147.04 5 130
Average= 4.90
(KJ/cycle)

Cycle 28 GMT 5/11/2024 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 24 15.08 545 197 0.20 / 136.87 5 30
2 7 2003.76 40 14.70 3515 2067 2.26 / 138.94 30 19
3 13 1292.68 20 14.86 2410 716 2.98 / 139.66 5 27
4 13 718.16 20 14.98 1531 459 3.44 / 140.12 5 32
5 13 134.56 20 15.16 586 178 3.62 / 140.29 5 38
6 8 0.28 334 15.13 334 1688 5.30 / 141.98 5 136
Average= 4.90
(KJ/cycle)

Cycle 27 GMT 26/10/2024 0:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 25 15.10 518 196 0.20 / 131.69 5 26
2 7 2002.64 41 14.69 3531 2127 2.32 / 133.82 26 18
3 13 1207.92 20 14.88 2285 680 3.00 / 134.50 5 26
4 13 744.88 20 14.98 1561 468 3.47 / 134.97 5 31
5 13 61.84 20 15.19 456 139 3.61 / 135.11 5 42
6 8 0.24 308 15.13 337 1570 5.18 / 136.68 5 130
Average= 4.88
(KJ/cycle)

Cycle 26 GMT 15/10/2024 17:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 25 15.09 553 209 0.21 / 126.60 5 26
2 7 2002.60 40 14.70 3502 2059 2.27 / 128.66 26 18
3 13 1311.64 20 14.85 2445 726 2.99 / 129.39 5 27
4 13 733.48 20 14.99 1534 460 3.45 / 129.85 5 33
5 13 73.88 20 15.19 474 144 3.60 / 129.99 5 40
6 8 0.00 297 15.14 335 1506 5.10 / 131.50 5 135
Average= 4.87
(KJ/cycle)

Cycle 25 GMT 5/10/2024 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 25 15.10 535 202 0.20 / 121.53 5 25
2 7 2010.08 40 14.71 3506 2063 2.26 / 123.59 25 18
3 13 1217.48 20 14.88 2307 687 2.95 / 124.28 5 29
4 13 755.68 20 14.98 1589 476 3.43 / 124.75 5 34
5 13 82.04 20 15.19 500 152 3.58 / 124.90 5 39
6 8 0.12 287 15.14 343 1490 5.07 / 126.39 5 134
Average= 4.86
(KJ/cycle)

Cycle 24 GMT 25/ 9/2024 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 25 15.10 561 212 0.21 / 116.39 5 26
2 7 2003.68 40 14.71 3488 2052 2.26 / 118.44 26 19
3 13 1302.48 20 14.87 2426 721 2.99 / 119.16 5 27
4 13 721.04 20 15.00 1532 460 3.45 / 119.62 5 33
5 13 151.68 20 15.17 607 184 3.63 / 119.80 5 38
6 8 0.04 293 15.14 343 1522 5.15 / 121.32 5 132
Average= 4.85
(KJ/cycle)

Cycle 23 GMT 14/ 9/2024 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 26 15.11 515 202 0.20 / 111.29 5 24
2 3 966.16 -1 15.48 0 0 0.00 / 111.29 5 24
3 7 2006.60 40 14.71 3534 2079 2.28 / 113.37 24 19
4 13 1280.76 20 14.88 2395 713 2.99 / 114.08 5 26
5 13 709.20 20 15.00 1495 448 3.44 / 114.53 5 32
6 13 56.60 20 15.20 454 138 3.58 / 114.67 5 40
7 8 0.20 287 15.15 346 1504 5.09 / 116.17 5 133
Average= 4.84
(KJ/cycle)

Cycle 22 GMT 4/ 9/2024 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 26 15.12 523 206 0.21 / 106.32 5 24
2 7 2010.56 40 14.72 3517 2071 2.28 / 108.39 24 20
3 13 1302.32 20 14.88 2435 725 3.00 / 109.11 5 27
4 13 736.92 20 15.00 1540 462 3.46 / 109.58 5 31
5 8 0.44 304 15.17 328 1513 4.98 / 111.09 5 133
Average= 4.83
(KJ/cycle)

Cycle 21 GMT 25/ 8/2024 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 15.12 534 218 0.22 / 101.28 5 23
2 7 2007.08 41 14.71 3549 2140 2.36 / 103.42 23 18
3 13 1213.60 20 14.90 2299 685 3.04 / 104.11 5 26
4 13 658.04 20 15.03 1420 427 3.47 / 104.53 5 36
5 13 17.52 20 15.22 387 118 3.59 / 104.65 5 38
6 8 0.16 282 15.16 342 1462 5.05 / 106.11 5 139
Average= 4.82
(KJ/cycle)

Cycle 20 GMT 15/ 8/2024 1:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 26 15.13 531 209 0.21 / 96.15 5 21
2 7 2004.16 40 14.73 3540 2086 2.29 / 98.23 21 18
3 13 1399.32 20 14.87 2559 761 3.06 / 98.99 5 27
4 13 799.00 20 14.99 1645 493 3.55 / 99.49 5 32
5 13 23.80 20 15.23 395 120 3.67 / 99.61 5 37
6 8 0.04 282 15.17 340 1454 5.12 / 101.06 5 136
Average= 4.81
(KJ/cycle)

Cycle 19 GMT 4/ 8/2024 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 26 15.13 517 203 0.20 / 91.04 5 21
2 7 2007.96 40 14.73 3524 2076 2.28 / 93.12 5 18
3 13 1306.28 20 14.89 2441 727 3.01 / 93.85 5 26
4 13 819.96 20 14.98 1689 506 3.51 / 94.35 5 32
5 13 55.40 20 15.22 445 135 3.65 / 94.49 5 36
6 8 0.04 278 15.17 344 1451 5.10 / 95.94 5 131
Average= 4.80
(KJ/cycle)

Cycle 18 GMT 25/ 7/2024 12:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 26 15.13 524 206 0.21 / 85.89 5 19
2 7 2006.08 40 14.72 3575 2105 2.31 / 88.00 19 19
3 13 1399.80 20 14.86 2590 770 3.08 / 88.77 5 26
4 13 717.40 20 15.02 1502 451 3.53 / 89.22 5 33
5 13 139.32 20 15.20 577 175 3.71 / 89.40 5 36
6 8 0.00 280 15.17 340 1444 5.15 / 90.84 5 138
Average= 4.78
(KJ/cycle)

Cycle 17 GMT 15/ 7/2024 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 15.13 554 218 0.22 / 80.72 5 20
2 7 2004.60 41 14.74 3556 2149 2.37 / 82.87 5 19
3 13 1301.56 20 14.89 2469 735 3.10 / 83.60 5 27
4 13 717.64 20 15.02 1510 454 3.56 / 84.06 5 33
5 13 120.44 20 15.21 566 172 3.73 / 84.23 5 34
6 8 0.24 278 15.17 346 1459 5.19 / 85.69 5 137
Average= 4.76
(KJ/cycle)

Cycle 16 GMT 4/ 7/2024 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 27 15.13 523 214 0.21 / 75.61 5 20
2 7 2005.60 40 14.75 3538 2087 2.30 / 77.69 20 18
3 13 1291.40 20 14.90 2442 728 3.03 / 78.42 5 27
4 13 720.16 20 15.02 1522 457 3.49 / 78.88 5 33
5 13 113.64 20 15.21 564 172 3.66 / 79.05 5 34
6 8 0.36 278 15.18 344 1452 5.11 / 80.50 5 150
Average= 4.74
(KJ/cycle)

Cycle 15 GMT 24/ 6/2024 17:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 27 15.16 499 204 0.20 / 70.42 5 19
2 7 2008.28 40 14.74 3564 2101 2.31 / 72.52 19 18
3 13 1297.60 20 14.90 2432 725 3.03 / 73.25 5 26
4 13 819.44 20 15.00 1673 502 3.53 / 73.75 5 32
5 13 97.36 20 15.22 522 159 3.69 / 73.91 5 36
6 8 0.28 278 15.18 351 1481 5.17 / 75.39 5 134
Average= 4.71
(KJ/cycle)

Cycle 14 GMT 14/ 6/2024 10:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 27 15.15 548 224 0.22 / 65.42 5 20
2 7 2002.84 40 14.76 3516 2076 2.30 / 67.50 5 20
3 13 1297.08 20 14.91 2420 722 3.02 / 68.22 5 28
4 13 724.68 20 15.04 1499 451 3.47 / 68.67 5 32
5 13 62.48 20 15.24 447 136 3.61 / 68.80 5 35
6 8 0.40 274 15.19 340 1415 5.02 / 70.22 5 132
Average= 4.68
(KJ/cycle)

Cycle 13 GMT 4/ 6/2024 4: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 27 15.15 538 220 0.22 / 60.19 5 18
2 7 2007.92 40 14.76 3560 2102 2.32 / 62.29 18 17
3 13 1415.44 20 14.88 2641 786 3.11 / 63.07 5 25
4 13 808.36 20 15.01 1666 500 3.61 / 63.57 5 32
5 13 101.64 20 15.23 518 158 3.77 / 63.73 5 34
6 8 0.08 276 15.19 349 1463 5.23 / 65.20 5 135
Average= 4.66
(KJ/cycle)

Cycle 12 GMT 24/ 5/2024 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 27 15.14 553 226 0.23 / 54.96 5 18
2 7 2009.72 40 14.76 3572 2109 2.33 / 57.07 18 18
3 13 1316.40 20 14.91 2469 736 3.07 / 57.80 5 26
4 13 847.28 20 15.00 1724 517 3.59 / 58.32 5 33
5 13 110.96 20 15.23 542 165 3.75 / 58.49 5 32
6 8 0.08 276 15.19 353 1480 5.23 / 59.97 5 134
Average= 4.61
(KJ/cycle)

Cycle 11 GMT 14/ 5/2024 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 27 15.15 527 216 0.22 / 49.67 5 20
2 7 2003.12 41 14.77 3534 2140 2.36 / 51.81 20 19
3 13 1389.36 20 14.90 2582 769 3.13 / 52.58 5 27
4 13 789.24 20 15.02 1647 495 3.62 / 53.07 5 30
5 13 90.48 20 15.24 516 157 3.78 / 53.23 5 33
6 13 9.04 20 15.25 383 117 3.89 / 53.35 5 34
7 8 0.28 255 15.19 358 1387 5.28 / 54.73 5 140
Average= 4.56
(KJ/cycle)

Cycle 10 GMT 4/ 5/2024 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 27 15.15 533 218 0.22 / 44.54 5 18
2 3 1026.16 1 15.17 2020 31 0.25 / 44.57 5 11
3 7 2006.04 40 14.77 3552 2099 2.35 / 46.67 11 19
4 13 1281.44 20 14.93 2389 713 3.06 / 47.39 5 26
5 13 701.40 20 15.05 1495 450 3.51 / 47.84 5 34
6 13 96.28 20 15.24 503 153 3.66 / 47.99 5 35
7 8 0.04 276 15.19 349 1463 5.13 / 49.45 5 145
Average= 4.50
(KJ/cycle)

Cycle 9 GMT 24/ 4/2024 2:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 27 15.16 527 216 0.22 / 39.32 5 19
2 7 2006.96 40 14.79 3519 2082 2.30 / 41.40 19 19
3 13 1393.32 20 14.91 2553 761 3.06 / 42.17 5 26
4 13 813.04 20 15.02 1671 502 3.56 / 42.67 5 30
5 13 96.20 20 15.23 526 160 3.72 / 42.83 5 34
6 8 0.08 276 15.20 357 1498 5.22 / 44.33 5 133
Average= 4.43
(KJ/cycle)

Cycle 8 GMT 13/ 4/2024 19:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 15.15 543 222 0.22 / 34.20 5 21
2 7 2002.56 40 14.79 3536 2092 2.31 / 36.29 21 19
3 13 1390.80 20 14.91 2559 763 3.08 / 37.05 5 26
4 13 696.68 20 15.06 1485 447 3.52 / 37.50 5 32
5 13 57.92 20 15.25 455 139 3.66 / 37.64 5 35
6 8 0.36 274 15.20 352 1466 5.13 / 39.11 5 134
Average= 4.35
(KJ/cycle)

Cycle 7 GMT 3/ 4/2024 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 27 15.15 533 218 0.22 / 29.04 5 20
2 7 2003.88 40 14.79 3526 2086 2.30 / 31.12 20 19
3 13 1300.12 20 14.93 2403 718 3.02 / 31.84 5 29
4 13 714.08 20 15.06 1503 453 3.47 / 32.29 5 32
5 13 116.96 20 15.23 560 171 3.64 / 32.47 5 36
6 8 0.08 278 15.19 358 1512 5.16 / 33.98 5 133
Average= 4.25
(KJ/cycle)

Cycle 6 GMT 24/ 3/2024 7: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 24 15.15 541 197 0.20 / 23.70 5 19
2 10 1033.96 3 15.08 2004 91 0.29 / 23.79 5 21
3 3 1019.12 1 15.17 1992 30 0.32 / 23.82 5 12
4 7 2002.92 40 14.80 3505 2075 2.39 / 25.90 12 20
5 13 1416.36 20 14.91 2603 776 3.17 / 26.67 5 26
6 13 810.60 20 15.03 1693 509 3.68 / 27.18 5 33
7 13 91.00 20 15.24 506 154 3.83 / 27.34 5 34
8 8 0.00 276 15.20 354 1485 5.32 / 28.82 5 130
Average= 4.12
(KJ/cycle)

Cycle 5 GMT 14/ 3/2024 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 31 15.15 537 252 0.25 / 18.58 5 20
2 3 819.88 -3 15.52 0 0 0.00 / 18.58 5 20
3 7 2005.48 40 14.80 3538 2094 2.35 / 20.67 20 18
4 13 1308.84 20 14.94 2438 728 3.08 / 21.40 5 27
5 13 657.28 20 15.07 1425 429 3.50 / 21.83 5 34
6 13 87.80 20 15.24 518 158 3.66 / 21.99 5 35
7 8 0.28 276 15.19 361 1513 5.18 / 23.50 5 137
Average= 3.92
(KJ/cycle)

Cycle 4 GMT 3/ 3/2024 17:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 26 15.15 559 220 0.22 / 14.08 5 19
2 7 1506.40 40 14.95 2755 1647 1.87 / 15.73 19 22
3 13 1098.80 20 15.03 2097 630 2.50 / 16.36 5 26
4 13 535.00 20 15.13 1225 371 2.87 / 16.73 5 33
5 13 36.96 20 15.27 424 129 3.00 / 16.86 5 38
6 8 0.16 272 15.21 355 1469 4.47 / 18.33 5 139
Average= 3.67
(KJ/cycle)

Cycle 3 GMT 2/ 3/2024 8: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 24 15.16 546 199 0.20 / 9.37 5 20
2 10 1020.72 3 15.07 1974 89 0.29 / 9.46 5 21
3 7 1524.96 40 14.95 2762 1652 1.94 / 11.11 21 23
4 13 1210.72 20 14.99 2288 686 2.63 / 11.80 5 27
5 13 618.96 20 15.10 1375 415 3.04 / 12.22 5 33
6 13 15.96 20 15.27 393 120 3.16 / 12.34 5 36
7 8 -0.24 278 15.20 361 1525 4.69 / 13.86 5 141
Average= 3.47
(KJ/cycle)

Cycle 2 GMT 29/ 2/2024 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 15.22 526 248 0.25 / 5.03 5 20
2 3 823.36 -3 15.55 0 0 0.00 / 5.03 5 20
3 7 1374.28 40 15.01 2547 1529 1.78 / 6.55 20 24
4 13 1084.80 20 15.05 2100 632 2.41 / 7.19 5 27
5 13 510.36 20 15.15 1192 361 2.77 / 7.55 5 32
6 13 15.52 20 15.29 387 118 2.89 / 7.67 5 37
7 8 0.08 276 15.22 359 1508 4.40 / 9.17 5 145
Average= 3.06
(KJ/cycle)

Cycle 1 GMT 28/ 2/2024 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 15.39 503 240 0.24 / 2.11 5 13
2 3 847.44 -2 15.58 0 0 0.00 / 2.11 5 13
3 7 879.00 40 15.15 1766 1070 1.31 / 3.18 13 27
4 13 46.40 20 15.35 437 134 1.44 / 3.32 5 36
5 8 -0.08 272 15.29 351 1460 2.90 / 4.78 5 131
Average= 2.39
(KJ/cycle)

Cycle 0 GMT 28/ 2/2024 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 15.56 495 231 0.23 / 0.23 5 8
2 7 123.04 40 15.54 497 309 0.54 / 0.54 8 10
3 8 0.28 291 15.48 296 1333 1.87 / 1.87 5 169
Average= 1.87
(KJ/cycle)