SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 39 | 14.94 | 514 | 299 | 0.30 / 537.38 | 6 | 8 |
2 | 7 | 2010.52 | 40 | 14.63 | 3236 | 1894 | 2.19 / 539.27 | 8 | 22 |
3 | 13 | 1564.48 | 20 | 14.65 | 2653 | 777 | 2.97 / 540.05 | 6 | 31 |
4 | 13 | 917.92 | 20 | 14.76 | 1744 | 515 | 3.49 / 540.57 | 6 | 38 |
5 | 13 | 338.76 | 20 | 14.94 | 887 | 265 | 3.75 / 540.83 | 6 | 35 |
6 | 8 | 0.08 | 319 | 14.97 | 378 | 1805 | 5.56 / 542.64 | 6 | 144 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 39 | 14.94 | 538 | 313 | 0.31 / 531.71 | 6 | 10 |
2 | 7 | 2009.72 | 40 | 14.63 | 3224 | 1887 | 2.20 / 533.60 | 10 | 23 |
3 | 13 | 1560.96 | 20 | 14.66 | 2622 | 769 | 2.97 / 534.37 | 6 | 30 |
4 | 13 | 1095.44 | 20 | 14.71 | 1997 | 588 | 3.56 / 534.95 | 6 | 36 |
5 | 13 | 393.24 | 20 | 14.92 | 973 | 290 | 3.85 / 535.24 | 6 | 36 |
6 | 13 | 53.36 | 20 | 15.03 | 466 | 140 | 3.99 / 535.38 | 6 | 28 |
7 | 8 | 0.16 | 300 | 14.96 | 378 | 1696 | 5.68 / 537.08 | 6 | 159 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.88 | 39 | 14.96 | 533 | 311 | 0.31 / 526.07 | 6 | 6 |
2 | 7 | 2020.00 | 40 | 14.62 | 3242 | 1896 | 2.21 / 527.97 | 23 | 22 |
3 | 13 | 1598.36 | 20 | 14.65 | 2679 | 785 | 2.99 / 528.75 | 6 | 30 |
4 | 13 | 1019.56 | 20 | 14.74 | 1863 | 549 | 3.54 / 529.30 | 6 | 38 |
5 | 13 | 315.52 | 20 | 14.95 | 862 | 258 | 3.80 / 529.56 | 6 | 38 |
6 | 8 | 0.12 | 321 | 14.97 | 383 | 1840 | 5.64 / 531.40 | 6 | -99 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 39 | 14.96 | 514 | 300 | 0.30 / 520.54 | 6 | 7 |
2 | 7 | 2006.64 | 40 | 14.63 | 3233 | 1892 | 2.19 / 522.43 | 26 | 25 |
3 | 13 | 1544.24 | 20 | 14.66 | 2602 | 763 | 2.95 / 523.19 | 6 | 31 |
4 | 13 | 992.08 | 20 | 14.74 | 1860 | 548 | 3.50 / 523.74 | 6 | 35 |
5 | 13 | 190.44 | 20 | 15.00 | 678 | 203 | 3.71 / 523.94 | 6 | 29 |
6 | 8 | 0.08 | 319 | 14.97 | 380 | 1815 | 5.52 / 525.76 | 6 | 195 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 39 | 14.95 | 516 | 301 | 0.30 / 514.92 | 6 | 7 |
2 | 7 | 2014.24 | 40 | 14.63 | 3232 | 1891 | 2.19 / 516.81 | 7 | 21 |
3 | 13 | 1573.04 | 20 | 14.65 | 2641 | 774 | 2.97 / 517.58 | 6 | 30 |
4 | 13 | 1117.04 | 20 | 14.70 | 1998 | 587 | 3.55 / 518.17 | 6 | 36 |
5 | 13 | 270.24 | 20 | 14.97 | 771 | 231 | 3.78 / 518.40 | 6 | 35 |
6 | 13 | 24.64 | 20 | 15.04 | 422 | 127 | 3.91 / 518.53 | 6 | 25 |
7 | 8 | 0.00 | 300 | 14.97 | 381 | 1711 | 5.62 / 520.24 | 6 | 170 |
Average= | 5.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 39 | 14.95 | 518 | 302 | 0.30 / 509.28 | 6 | 7 |
2 | 7 | 2018.64 | 41 | 14.62 | 3228 | 1935 | 2.24 / 511.22 | 7 | 23 |
3 | 13 | 1573.40 | 20 | 14.65 | 2641 | 774 | 3.01 / 511.99 | 6 | 30 |
4 | 13 | 980.12 | 20 | 14.74 | 1836 | 541 | 3.55 / 512.53 | 6 | 36 |
5 | 13 | 276.48 | 20 | 14.97 | 803 | 240 | 3.79 / 512.77 | 6 | 35 |
6 | 8 | 0.08 | 319 | 14.97 | 386 | 1843 | 5.64 / 514.62 | 6 | 163 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 39 | 14.95 | 517 | 301 | 0.30 / 503.64 | 6 | 7 |
2 | 7 | 2009.64 | 40 | 14.62 | 3218 | 1882 | 2.18 / 505.52 | 7 | 22 |
3 | 13 | 1556.64 | 20 | 14.66 | 2646 | 776 | 2.96 / 506.30 | 6 | 30 |
4 | 13 | 975.36 | 20 | 14.74 | 1832 | 540 | 3.50 / 506.84 | 6 | 37 |
5 | 13 | 383.68 | 20 | 14.92 | 970 | 289 | 3.79 / 507.13 | 6 | 39 |
6 | 8 | 0.16 | 321 | 14.96 | 386 | 1854 | 5.64 / 508.98 | 6 | 184 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 39 | 14.95 | 537 | 313 | 0.31 / 497.94 | 6 | 6 |
2 | 7 | 2013.36 | 40 | 14.63 | 3243 | 1898 | 2.21 / 499.84 | 6 | 22 |
3 | 13 | 1574.68 | 20 | 14.64 | 2675 | 783 | 2.99 / 500.63 | 6 | 29 |
4 | 13 | 1102.68 | 20 | 14.71 | 2014 | 593 | 3.59 / 501.22 | 6 | 35 |
5 | 13 | 369.92 | 20 | 14.94 | 950 | 284 | 3.87 / 501.50 | 6 | 37 |
6 | 8 | 0.00 | 321 | 14.97 | 382 | 1836 | 5.71 / 503.34 | 6 | 179 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 39 | 14.95 | 523 | 305 | 0.30 / 492.40 | 6 | 6 |
2 | 7 | 2018.80 | 40 | 14.62 | 3238 | 1894 | 2.20 / 494.29 | 6 | 22 |
3 | 13 | 1573.88 | 20 | 14.66 | 2639 | 774 | 2.97 / 495.07 | 6 | 30 |
4 | 13 | 896.80 | 20 | 14.77 | 1699 | 502 | 3.47 / 495.57 | 6 | 37 |
5 | 13 | 233.64 | 20 | 14.98 | 742 | 222 | 3.70 / 495.79 | 6 | 32 |
6 | 8 | 0.00 | 319 | 14.97 | 385 | 1839 | 5.54 / 497.63 | 6 | -99 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 39 | 14.94 | 540 | 315 | 0.31 / 486.80 | 6 | 8 |
2 | 7 | 2014.56 | 40 | 14.64 | 3235 | 1894 | 2.21 / 488.69 | 8 | 24 |
3 | 13 | 1570.92 | 20 | 14.66 | 2639 | 774 | 2.98 / 489.46 | 6 | 31 |
4 | 13 | 995.72 | 20 | 14.74 | 1862 | 549 | 3.53 / 490.01 | 6 | 35 |
5 | 13 | 298.48 | 20 | 14.96 | 834 | 250 | 3.78 / 490.26 | 6 | 37 |
6 | 8 | -0.04 | 319 | 14.97 | 384 | 1834 | 5.62 / 492.10 | 6 | 149 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 39 | 14.95 | 520 | 303 | 0.30 / 481.21 | 6 | 7 |
2 | 7 | 2008.36 | 40 | 14.63 | 3222 | 1886 | 2.19 / 483.09 | 7 | 24 |
3 | 13 | 1451.92 | 20 | 14.67 | 2492 | 731 | 2.92 / 483.82 | 6 | 30 |
4 | 13 | 1014.96 | 20 | 14.73 | 1886 | 556 | 3.48 / 484.38 | 6 | 36 |
5 | 13 | 393.48 | 20 | 14.92 | 984 | 294 | 3.77 / 484.67 | 6 | 36 |
6 | 8 | 0.08 | 319 | 14.97 | 379 | 1810 | 5.58 / 486.48 | 6 | 154 |
Average= | 5.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 39 | 14.94 | 523 | 305 | 0.30 / 475.65 | 6 | 8 |
2 | 7 | 2015.32 | 40 | 14.63 | 3231 | 1891 | 2.20 / 477.55 | 8 | 24 |
3 | 13 | 1574.12 | 20 | 14.66 | 2657 | 779 | 2.97 / 478.32 | 6 | 30 |
4 | 13 | 918.72 | 20 | 14.77 | 1752 | 518 | 3.49 / 478.84 | 6 | 37 |
5 | 13 | 218.12 | 20 | 15.00 | 717 | 215 | 3.71 / 479.06 | 6 | 35 |
6 | 8 | 0.00 | 319 | 14.98 | 386 | 1845 | 5.55 / 480.90 | 6 | 174 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 39 | 14.95 | 503 | 293 | 0.29 / 469.95 | 6 | 8 |
2 | 7 | 2005.00 | 40 | 14.64 | 3218 | 1884 | 2.18 / 471.84 | 8 | 23 |
3 | 13 | 1568.20 | 20 | 14.66 | 2663 | 781 | 2.96 / 472.62 | 6 | 29 |
4 | 13 | 1109.64 | 20 | 14.71 | 2017 | 593 | 3.55 / 473.21 | 6 | 35 |
5 | 13 | 374.48 | 20 | 14.94 | 953 | 285 | 3.84 / 473.50 | 6 | 38 |
6 | 8 | 0.08 | 321 | 14.97 | 386 | 1855 | 5.69 / 475.35 | 6 | 163 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 39 | 14.95 | 531 | 310 | 0.31 / 464.34 | 6 | 7 |
2 | 7 | 2012.72 | 40 | 14.64 | 3228 | 1890 | 2.20 / 466.23 | 7 | 21 |
3 | 13 | 1555.68 | 20 | 14.68 | 2616 | 768 | 2.97 / 467.00 | 6 | 30 |
4 | 13 | 1087.80 | 20 | 14.72 | 1990 | 586 | 3.55 / 467.59 | 6 | 34 |
5 | 13 | 269.96 | 20 | 14.98 | 796 | 238 | 3.79 / 467.82 | 6 | 34 |
6 | 8 | -0.04 | 319 | 14.98 | 384 | 1835 | 5.63 / 469.66 | 6 | 153 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 39 | 14.94 | 527 | 307 | 0.31 / 458.74 | 6 | 7 |
2 | 7 | 2004.04 | 40 | 14.65 | 3214 | 1883 | 2.19 / 460.62 | 7 | 22 |
3 | 13 | 1564.60 | 20 | 14.67 | 2619 | 768 | 2.96 / 461.39 | 6 | 30 |
4 | 13 | 1006.44 | 20 | 14.75 | 1847 | 545 | 3.50 / 461.93 | 6 | 33 |
5 | 13 | 221.16 | 20 | 15.00 | 726 | 218 | 3.72 / 462.15 | 6 | 34 |
6 | 8 | 0.08 | 319 | 14.97 | 394 | 1882 | 5.60 / 464.03 | 6 | 148 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 39 | 14.94 | 530 | 309 | 0.31 / 453.12 | 6 | 8 |
2 | 7 | 2009.12 | 40 | 14.64 | 3228 | 1890 | 2.20 / 455.01 | 8 | 23 |
3 | 13 | 1585.44 | 20 | 14.67 | 2653 | 778 | 2.98 / 455.79 | 6 | 29 |
4 | 13 | 1011.00 | 20 | 14.74 | 1869 | 551 | 3.53 / 456.34 | 6 | 36 |
5 | 13 | 234.08 | 20 | 14.99 | 743 | 223 | 3.75 / 456.56 | 6 | 32 |
6 | 8 | -0.04 | 321 | 14.97 | 388 | 1864 | 5.62 / 458.43 | 6 | 156 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 39 | 14.94 | 534 | 311 | 0.31 / 447.42 | 6 | 9 |
2 | 7 | 2014.44 | 40 | 14.64 | 3249 | 1903 | 2.21 / 449.32 | 9 | 21 |
3 | 13 | 1587.40 | 20 | 14.66 | 2686 | 788 | 3.00 / 450.11 | 6 | 29 |
4 | 13 | 1013.20 | 20 | 14.74 | 1881 | 555 | 3.56 / 450.66 | 6 | 36 |
5 | 13 | 322.04 | 20 | 14.96 | 874 | 262 | 3.82 / 450.92 | 6 | 35 |
6 | 8 | 0.24 | 323 | 14.97 | 391 | 1891 | 5.71 / 452.81 | 6 | 194 |
Average= | 5.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 39 | 14.93 | 538 | 313 | 0.31 / 441.67 | 6 | 9 |
2 | 7 | 2011.48 | 40 | 14.64 | 3247 | 1901 | 2.21 / 443.57 | 9 | 21 |
3 | 13 | 1577.40 | 20 | 14.66 | 2679 | 785 | 3.00 / 444.35 | 6 | 29 |
4 | 13 | 1095.16 | 20 | 14.72 | 2004 | 590 | 3.59 / 444.94 | 6 | 35 |
5 | 13 | 366.52 | 20 | 14.94 | 950 | 284 | 3.87 / 445.23 | 6 | 35 |
6 | 8 | 0.12 | 321 | 14.97 | 391 | 1879 | 5.75 / 447.10 | 6 | 144 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 39 | 14.94 | 539 | 314 | 0.31 / 435.94 | 6 | 9 |
2 | 7 | 2022.36 | 40 | 14.64 | 3254 | 1906 | 2.22 / 437.84 | 9 | 20 |
3 | 13 | 1584.60 | 20 | 14.66 | 2694 | 790 | 3.01 / 438.63 | 6 | 29 |
4 | 13 | 1114.36 | 20 | 14.71 | 2029 | 597 | 3.61 / 439.23 | 6 | 35 |
5 | 13 | 298.24 | 20 | 14.97 | 832 | 249 | 3.86 / 439.48 | 6 | 32 |
6 | 8 | 0.12 | 321 | 14.97 | 390 | 1874 | 5.73 / 441.35 | 6 | 184 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 39 | 14.93 | 539 | 314 | 0.31 / 430.37 | 6 | 10 |
2 | 7 | 2011.36 | 40 | 14.65 | 3223 | 1889 | 2.20 / 432.25 | 15 | 21 |
3 | 13 | 1481.80 | 20 | 14.68 | 2518 | 739 | 2.94 / 432.99 | 6 | 30 |
4 | 13 | 1037.20 | 20 | 14.73 | 1914 | 564 | 3.51 / 433.56 | 6 | 35 |
5 | 13 | 219.44 | 20 | 15.00 | 718 | 215 | 3.72 / 433.77 | 6 | 30 |
6 | 8 | 0.00 | 319 | 14.98 | 387 | 1849 | 5.57 / 435.62 | 6 | 185 |
Average= | 5.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 39 | 14.93 | 535 | 312 | 0.31 / 424.70 | 6 | 9 |
2 | 7 | 2017.56 | 40 | 14.64 | 3242 | 1899 | 2.21 / 426.60 | 9 | 23 |
3 | 13 | 1587.44 | 20 | 14.67 | 2658 | 780 | 2.99 / 427.37 | 6 | 28 |
4 | 13 | 1018.32 | 20 | 14.75 | 1863 | 550 | 3.54 / 427.92 | 6 | 36 |
5 | 13 | 323.32 | 20 | 14.96 | 862 | 258 | 3.80 / 428.18 | 6 | 34 |
6 | 8 | 0.04 | 321 | 14.97 | 389 | 1869 | 5.67 / 430.05 | 6 | 180 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 39 | 14.93 | 552 | 321 | 0.32 / 419.08 | 6 | 10 |
2 | 7 | 2004.76 | 40 | 14.64 | 3225 | 1889 | 2.21 / 420.97 | 10 | 22 |
3 | 13 | 1556.56 | 20 | 14.67 | 2633 | 773 | 2.98 / 421.74 | 6 | 29 |
4 | 13 | 986.60 | 20 | 14.76 | 1849 | 546 | 3.53 / 422.29 | 6 | 36 |
5 | 13 | 202.60 | 20 | 15.00 | 693 | 208 | 3.74 / 422.50 | 6 | 32 |
6 | 8 | -0.04 | 321 | 14.97 | 393 | 1889 | 5.62 / 424.39 | 6 | 235 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 39 | 14.93 | 560 | 326 | 0.33 / 413.43 | 6 | 9 |
2 | 7 | 2007.36 | 40 | 14.65 | 3218 | 1886 | 2.21 / 415.32 | 9 | 22 |
3 | 13 | 1561.80 | 20 | 14.67 | 2649 | 777 | 2.99 / 416.10 | 6 | 29 |
4 | 13 | 1003.40 | 20 | 14.75 | 1865 | 550 | 3.54 / 416.65 | 6 | 36 |
5 | 13 | 209.04 | 20 | 15.00 | 701 | 210 | 3.75 / 416.86 | 6 | 30 |
6 | 8 | 0.24 | 321 | 14.97 | 396 | 1903 | 5.65 / 418.76 | 6 | 197 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 39 | 14.93 | 556 | 324 | 0.32 / 407.74 | 6 | 8 |
2 | 7 | 2014.76 | 40 | 14.65 | 3228 | 1892 | 2.22 / 409.63 | 8 | 22 |
3 | 13 | 1578.72 | 20 | 14.67 | 2659 | 780 | 3.00 / 410.41 | 6 | 29 |
4 | 13 | 997.32 | 20 | 14.75 | 1861 | 549 | 3.54 / 410.96 | 6 | 36 |
5 | 13 | 309.68 | 20 | 14.96 | 854 | 256 | 3.80 / 411.22 | 6 | 32 |
6 | 8 | 0.12 | 321 | 14.97 | 393 | 1889 | 5.69 / 413.11 | 6 | -99 |
Average= | 5.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 39 | 14.93 | 533 | 310 | 0.31 / 402.08 | 6 | 7 |
2 | 7 | 2017.00 | 40 | 14.65 | 3231 | 1893 | 2.20 / 403.97 | 7 | 22 |
3 | 13 | 1584.36 | 20 | 14.67 | 2653 | 778 | 2.98 / 404.75 | 6 | 28 |
4 | 13 | 1005.84 | 20 | 14.75 | 1846 | 545 | 3.53 / 405.30 | 6 | 36 |
5 | 13 | 299.12 | 20 | 14.96 | 836 | 250 | 3.78 / 405.55 | 6 | 30 |
6 | 8 | -0.04 | 321 | 14.97 | 390 | 1874 | 5.65 / 407.42 | 6 | 184 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 39 | 14.94 | 548 | 319 | 0.32 / 396.40 | 6 | 17 |
2 | 7 | 2013.88 | 40 | 14.65 | 3232 | 1894 | 2.21 / 398.29 | 17 | 22 |
3 | 13 | 1589.88 | 20 | 14.67 | 2668 | 783 | 3.00 / 399.08 | 6 | 25 |
4 | 13 | 1035.36 | 20 | 14.73 | 1890 | 557 | 3.55 / 399.63 | 6 | 36 |
5 | 13 | 339.16 | 20 | 14.95 | 896 | 268 | 3.82 / 399.90 | 6 | 33 |
6 | 8 | 0.20 | 319 | 14.97 | 391 | 1867 | 5.69 / 401.77 | 6 | 135 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 39 | 14.93 | 544 | 317 | 0.32 / 390.75 | 6 | 9 |
2 | 7 | 2006.52 | 40 | 14.65 | 3214 | 1883 | 2.20 / 392.63 | 9 | 21 |
3 | 13 | 1573.40 | 20 | 14.67 | 2633 | 773 | 2.97 / 393.41 | 6 | 28 |
4 | 13 | 1089.36 | 20 | 14.73 | 1975 | 582 | 3.55 / 393.99 | 6 | 35 |
5 | 13 | 266.52 | 20 | 14.98 | 785 | 235 | 3.79 / 394.22 | 6 | 33 |
6 | 8 | 0.00 | 319 | 14.97 | 389 | 1858 | 5.65 / 396.08 | 6 | 147 |
Average= | 5.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 39 | 14.94 | 521 | 304 | 0.30 / 385.07 | 6 | 8 |
2 | 7 | 2013.96 | 40 | 14.65 | 3231 | 1893 | 2.20 / 386.96 | 8 | 23 |
3 | 13 | 1577.20 | 20 | 14.68 | 2636 | 774 | 2.97 / 387.74 | 6 | 29 |
4 | 13 | 1007.88 | 20 | 14.74 | 1880 | 554 | 3.53 / 388.29 | 6 | 34 |
5 | 13 | 315.08 | 20 | 14.96 | 865 | 259 | 3.78 / 388.55 | 6 | 34 |
6 | 8 | 0.16 | 321 | 14.97 | 392 | 1884 | 5.67 / 390.43 | 6 | 161 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 39 | 14.94 | 532 | 310 | 0.31 / 379.47 | 6 | 8 |
2 | 7 | 2009.36 | 40 | 14.64 | 3247 | 1901 | 2.21 / 381.37 | 8 | 23 |
3 | 13 | 1577.16 | 20 | 14.66 | 2666 | 782 | 2.99 / 382.15 | 6 | 31 |
4 | 13 | 1012.32 | 20 | 14.74 | 1886 | 556 | 3.55 / 382.71 | 6 | 35 |
5 | 13 | 209.28 | 20 | 15.00 | 707 | 212 | 3.76 / 382.92 | 6 | 30 |
6 | 8 | -0.16 | 319 | 14.97 | 386 | 1843 | 5.60 / 384.77 | 6 | 170 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 39 | 14.94 | 532 | 310 | 0.31 / 373.77 | 6 | 10 |
2 | 7 | 2012.04 | 41 | 14.65 | 3221 | 1935 | 2.24 / 375.70 | 10 | 23 |
3 | 13 | 1661.04 | 20 | 14.66 | 2773 | 813 | 3.06 / 376.52 | 6 | 29 |
4 | 13 | 1047.16 | 20 | 14.73 | 1938 | 571 | 3.63 / 377.09 | 6 | 36 |
5 | 13 | 232.24 | 20 | 14.99 | 739 | 222 | 3.85 / 377.31 | 6 | 32 |
6 | 8 | 0.08 | 319 | 14.97 | 388 | 1853 | 5.70 / 379.16 | 6 | 210 |
Average= | 5.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 39 | 14.94 | 522 | 304 | 0.30 / 368.17 | 6 | 7 |
2 | 7 | 2010.00 | 40 | 14.65 | 3228 | 1892 | 2.20 / 370.06 | 7 | 25 |
3 | 13 | 1497.00 | 20 | 14.68 | 2564 | 753 | 2.95 / 370.82 | 6 | 31 |
4 | 13 | 1044.76 | 20 | 14.73 | 1931 | 569 | 3.52 / 371.38 | 6 | 37 |
5 | 13 | 255.88 | 20 | 14.98 | 768 | 230 | 3.75 / 371.61 | 6 | 30 |
6 | 8 | 0.12 | 319 | 14.97 | 386 | 1843 | 5.59 / 373.46 | 6 | 184 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 39 | 14.94 | 522 | 304 | 0.30 / 362.66 | 6 | 7 |
2 | 7 | 2007.64 | 40 | 14.65 | 3219 | 1886 | 2.19 / 364.55 | 7 | 21 |
3 | 13 | 1557.36 | 20 | 14.68 | 2615 | 768 | 2.96 / 365.31 | 6 | 30 |
4 | 13 | 991.12 | 20 | 14.75 | 1844 | 544 | 3.50 / 365.86 | 6 | 35 |
5 | 13 | 188.60 | 20 | 15.00 | 670 | 201 | 3.70 / 366.06 | 6 | 30 |
6 | 8 | 0.00 | 317 | 14.97 | 381 | 1808 | 5.51 / 367.87 | 6 | 141 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 39 | 14.96 | 514 | 300 | 0.30 / 357.11 | 6 | 7 |
2 | 7 | 2009.08 | 40 | 14.65 | 3240 | 1899 | 2.20 / 359.01 | 7 | 23 |
3 | 13 | 1567.76 | 20 | 14.68 | 2650 | 778 | 2.98 / 359.79 | 6 | 29 |
4 | 13 | 1010.76 | 20 | 14.75 | 1874 | 553 | 3.53 / 360.34 | 6 | 36 |
5 | 13 | 220.28 | 20 | 14.99 | 704 | 211 | 3.74 / 360.55 | 6 | 27 |
6 | 8 | 0.28 | 319 | 14.98 | 378 | 1806 | 5.55 / 362.36 | 6 | 179 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 39 | 14.94 | 532 | 310 | 0.31 / 351.65 | 6 | 8 |
2 | 7 | 2013.48 | 40 | 14.66 | 3227 | 1892 | 2.20 / 353.54 | 8 | 21 |
3 | 13 | 1477.76 | 20 | 14.70 | 2502 | 736 | 2.94 / 354.28 | 6 | 30 |
4 | 13 | 925.40 | 20 | 14.77 | 1734 | 512 | 3.45 / 354.79 | 6 | 36 |
5 | 13 | 243.60 | 20 | 14.99 | 747 | 224 | 3.67 / 355.01 | 6 | 35 |
6 | 8 | 0.00 | 317 | 14.98 | 378 | 1795 | 5.47 / 356.81 | 6 | 200 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 39 | 14.95 | 521 | 304 | 0.30 / 346.01 | 6 | 8 |
2 | 7 | 2021.88 | 40 | 14.66 | 3236 | 1898 | 2.20 / 347.91 | 8 | 23 |
3 | 13 | 1572.36 | 20 | 14.69 | 2630 | 773 | 2.97 / 348.68 | 6 | 27 |
4 | 13 | 1000.48 | 20 | 14.76 | 1831 | 541 | 3.51 / 349.22 | 6 | 36 |
5 | 13 | 400.00 | 20 | 14.93 | 988 | 295 | 3.81 / 349.52 | 6 | 38 |
6 | 8 | -0.16 | 319 | 14.97 | 382 | 1824 | 5.63 / 351.34 | 6 | 181 |
Average= | 5.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 39 | 14.96 | 533 | 311 | 0.31 / 340.47 | 6 | 7 |
2 | 7 | 2015.44 | 40 | 14.67 | 3230 | 1895 | 2.21 / 342.37 | 7 | 24 |
3 | 13 | 1584.16 | 20 | 14.68 | 2679 | 787 | 2.99 / 343.16 | 6 | 28 |
4 | 13 | 999.20 | 20 | 14.76 | 1858 | 548 | 3.54 / 343.71 | 6 | 37 |
5 | 13 | 211.88 | 20 | 15.01 | 702 | 211 | 3.75 / 343.92 | 6 | 30 |
6 | 8 | 0.20 | 317 | 14.98 | 377 | 1790 | 5.54 / 345.71 | 6 | 150 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 39 | 14.97 | 523 | 305 | 0.31 / 334.89 | 6 | 8 |
2 | 7 | 2011.32 | 40 | 14.66 | 3222 | 1889 | 2.19 / 336.78 | 8 | 21 |
3 | 13 | 1681.20 | 20 | 14.68 | 2790 | 819 | 3.01 / 337.60 | 6 | 28 |
4 | 13 | 996.44 | 20 | 14.77 | 1834 | 542 | 3.56 / 338.15 | 6 | 36 |
5 | 13 | 224.92 | 20 | 15.00 | 720 | 216 | 3.77 / 338.36 | 6 | 31 |
6 | 8 | -0.12 | 319 | 14.99 | 377 | 1803 | 5.57 / 340.16 | 6 | 178 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 39 | 14.96 | 513 | 299 | 0.30 / 329.37 | 6 | 8 |
2 | 7 | 2010.08 | 40 | 14.67 | 3227 | 1894 | 2.19 / 331.26 | 8 | 23 |
3 | 13 | 1558.56 | 20 | 14.69 | 2633 | 774 | 2.97 / 332.04 | 6 | 30 |
4 | 13 | 996.04 | 20 | 14.77 | 1854 | 548 | 3.51 / 332.59 | 6 | 35 |
5 | 13 | 203.04 | 20 | 15.01 | 688 | 207 | 3.72 / 332.79 | 6 | 31 |
6 | 8 | 0.08 | 319 | 14.99 | 376 | 1798 | 5.52 / 334.59 | 6 | -99 |
Average= | 5.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 39 | 14.96 | 522 | 305 | 0.30 / 323.81 | 6 | 6 |
2 | 7 | 2016.08 | 40 | 14.66 | 3253 | 1908 | 2.21 / 325.72 | 6 | 23 |
3 | 13 | 1491.92 | 20 | 14.69 | 2550 | 749 | 2.96 / 326.47 | 6 | 29 |
4 | 13 | 1055.92 | 20 | 14.75 | 1939 | 572 | 3.53 / 327.04 | 6 | 35 |
5 | 13 | 246.88 | 20 | 15.00 | 755 | 226 | 3.76 / 327.27 | 6 | 30 |
6 | 8 | 0.16 | 319 | 14.99 | 377 | 1803 | 5.56 / 329.07 | 6 | 149 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 39 | 14.98 | 519 | 303 | 0.30 / 318.17 | 6 | 7 |
2 | 7 | 2021.84 | 40 | 14.66 | 3258 | 1910 | 2.21 / 320.08 | 7 | 23 |
3 | 13 | 1592.08 | 20 | 14.68 | 2688 | 789 | 3.00 / 320.87 | 6 | 29 |
4 | 13 | 1030.44 | 20 | 14.76 | 1907 | 563 | 3.57 / 321.44 | 6 | 35 |
5 | 13 | 298.28 | 20 | 14.98 | 833 | 250 | 3.82 / 321.69 | 6 | 32 |
6 | 8 | 0.04 | 319 | 14.99 | 381 | 1822 | 5.64 / 323.51 | 6 | 155 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 39 | 14.98 | 524 | 306 | 0.31 / 312.70 | 6 | 6 |
2 | 7 | 2014.64 | 41 | 14.67 | 3229 | 1942 | 2.25 / 314.64 | 6 | 24 |
3 | 13 | 1460.12 | 20 | 14.72 | 2473 | 728 | 2.98 / 315.37 | 6 | 32 |
4 | 13 | 922.16 | 20 | 14.79 | 1726 | 511 | 3.49 / 315.88 | 6 | 36 |
5 | 13 | 149.40 | 20 | 15.04 | 609 | 183 | 3.67 / 316.06 | 6 | 29 |
6 | 8 | 0.16 | 317 | 15.00 | 380 | 1807 | 5.48 / 317.87 | 6 | 145 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 39 | 14.97 | 522 | 305 | 0.30 / 307.18 | 6 | 9 |
2 | 7 | 2010.24 | 40 | 14.67 | 3235 | 1898 | 2.20 / 309.07 | 15 | 25 |
3 | 13 | 1560.16 | 20 | 14.71 | 2618 | 770 | 2.97 / 309.85 | 6 | 29 |
4 | 13 | 984.48 | 20 | 14.78 | 1839 | 544 | 3.52 / 310.39 | 6 | 36 |
5 | 13 | 170.84 | 20 | 15.04 | 640 | 193 | 3.71 / 310.58 | 6 | 34 |
6 | 8 | -0.12 | 317 | 15.01 | 381 | 1813 | 5.52 / 312.39 | 6 | 200 |
Average= | 5.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 39 | 14.99 | 514 | 300 | 0.30 / 301.57 | 6 | 7 |
2 | 7 | 2021.36 | 40 | 14.67 | 3248 | 1906 | 2.21 / 303.48 | 7 | 24 |
3 | 13 | 1592.16 | 20 | 14.69 | 2687 | 789 | 3.00 / 304.27 | 6 | 29 |
4 | 13 | 1028.92 | 20 | 14.77 | 1902 | 562 | 3.56 / 304.83 | 6 | 37 |
5 | 13 | 231.28 | 20 | 15.03 | 731 | 220 | 3.78 / 305.05 | 6 | 34 |
6 | 8 | 0.08 | 319 | 15.01 | 381 | 1824 | 5.60 / 306.87 | 6 | -99 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 39 | 14.99 | 525 | 307 | 0.31 / 295.99 | 6 | 8 |
2 | 7 | 2007.68 | 41 | 14.67 | 3232 | 1944 | 2.25 / 297.94 | 8 | 24 |
3 | 13 | 1563.16 | 20 | 14.71 | 2636 | 776 | 3.03 / 298.71 | 6 | 31 |
4 | 13 | 991.64 | 20 | 14.79 | 1848 | 547 | 3.57 / 299.26 | 6 | 35 |
5 | 13 | 185.32 | 20 | 15.05 | 658 | 198 | 3.77 / 299.46 | 6 | 35 |
6 | 8 | -0.04 | 317 | 15.02 | 381 | 1814 | 5.59 / 301.27 | 6 | 157 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 39 | 15.00 | 525 | 307 | 0.31 / 290.38 | 6 | 7 |
2 | 7 | 2015.84 | 40 | 14.68 | 3221 | 1891 | 2.20 / 292.27 | 23 | 23 |
3 | 13 | 1681.64 | 20 | 14.70 | 2781 | 818 | 3.02 / 293.09 | 6 | 28 |
4 | 13 | 972.44 | 20 | 14.81 | 1822 | 540 | 3.56 / 293.63 | 6 | 35 |
5 | 13 | 281.76 | 20 | 15.02 | 812 | 244 | 3.80 / 293.88 | 6 | 36 |
6 | 8 | 0.20 | 317 | 15.02 | 380 | 1809 | 5.61 / 295.69 | 6 | 134 |
Average= | 5.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 39 | 14.99 | 524 | 306 | 0.31 / 284.86 | 6 | 8 |
2 | 7 | 2012.36 | 40 | 14.69 | 3217 | 1890 | 2.20 / 286.75 | 8 | 24 |
3 | 13 | 1562.72 | 20 | 14.72 | 2618 | 771 | 2.97 / 287.52 | 6 | 31 |
4 | 13 | 982.72 | 20 | 14.81 | 1810 | 536 | 3.50 / 288.06 | 6 | 37 |
5 | 13 | 166.80 | 20 | 15.07 | 636 | 192 | 3.70 / 288.25 | 6 | 34 |
6 | 8 | 0.04 | 317 | 15.03 | 383 | 1825 | 5.52 / 290.08 | 6 | 132 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 39 | 14.99 | 541 | 316 | 0.32 / 279.15 | 6 | 9 |
2 | 7 | 2007.20 | 40 | 14.69 | 3219 | 1891 | 2.21 / 281.04 | 9 | 23 |
3 | 13 | 1479.56 | 20 | 14.74 | 2504 | 738 | 2.95 / 281.78 | 6 | 31 |
4 | 13 | 1028.84 | 20 | 14.80 | 1888 | 559 | 3.50 / 282.34 | 6 | 36 |
5 | 13 | 408.40 | 20 | 14.97 | 1013 | 303 | 3.81 / 282.64 | 6 | 39 |
6 | 8 | -0.08 | 323 | 15.02 | 395 | 1916 | 5.72 / 284.56 | 6 | 180 |
Average= | 5.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 39 | 14.99 | 532 | 311 | 0.31 / 273.41 | 6 | 10 |
2 | 7 | 2019.16 | 41 | 14.68 | 3237 | 1948 | 2.26 / 275.36 | 10 | 24 |
3 | 13 | 1572.40 | 20 | 14.72 | 2633 | 775 | 3.03 / 276.14 | 6 | 30 |
4 | 13 | 991.20 | 20 | 14.82 | 1829 | 542 | 3.58 / 276.68 | 6 | 37 |
5 | 13 | 281.40 | 20 | 15.03 | 818 | 246 | 3.82 / 276.93 | 6 | 36 |
6 | 8 | 0.00 | 321 | 15.03 | 395 | 1906 | 5.73 / 278.83 | 6 | 145 |
Average= | 5.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 39 | 15.00 | 538 | 315 | 0.31 / 267.81 | 6 | 10 |
2 | 7 | 2008.36 | 40 | 14.70 | 3235 | 1902 | 2.22 / 269.71 | 10 | 23 |
3 | 13 | 1567.52 | 20 | 14.72 | 2646 | 779 | 3.00 / 270.49 | 6 | 30 |
4 | 13 | 990.56 | 20 | 14.83 | 1841 | 546 | 3.54 / 271.03 | 6 | 37 |
5 | 13 | 201.48 | 20 | 15.07 | 685 | 206 | 3.75 / 271.24 | 6 | 34 |
6 | 8 | 0.08 | 321 | 15.04 | 386 | 1864 | 5.61 / 273.10 | 6 | 160 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 39 | 15.00 | 535 | 313 | 0.31 / 262.25 | 6 | 11 |
2 | 7 | 2020.28 | 40 | 14.69 | 3234 | 1900 | 2.21 / 264.15 | 11 | 23 |
3 | 13 | 1594.20 | 20 | 14.73 | 2666 | 785 | 3.00 / 264.94 | 6 | 30 |
4 | 13 | 914.12 | 20 | 14.85 | 1735 | 515 | 3.51 / 265.45 | 6 | 37 |
5 | 13 | 138.80 | 20 | 15.10 | 596 | 180 | 3.69 / 265.63 | 6 | 34 |
6 | 8 | 0.24 | 321 | 15.04 | 385 | 1859 | 5.55 / 267.49 | 6 | 183 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 39 | 15.01 | 540 | 316 | 0.32 / 256.62 | 6 | 10 |
2 | 7 | 2011.28 | 40 | 14.70 | 3226 | 1897 | 2.21 / 258.52 | 10 | 24 |
3 | 13 | 1566.32 | 20 | 14.74 | 2617 | 771 | 2.98 / 259.29 | 6 | 29 |
4 | 13 | 991.96 | 20 | 14.83 | 1837 | 545 | 3.53 / 259.84 | 6 | 37 |
5 | 13 | 206.48 | 20 | 15.07 | 707 | 213 | 3.74 / 260.05 | 6 | 36 |
6 | 8 | 0.04 | 321 | 15.05 | 391 | 1889 | 5.63 / 261.94 | 6 | 176 |
Average= | 5.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 39 | 15.01 | 522 | 306 | 0.31 / 250.96 | 6 | 8 |
2 | 7 | 2011.20 | 40 | 14.69 | 3237 | 1902 | 2.21 / 252.87 | 8 | 23 |
3 | 13 | 1663.16 | 20 | 14.72 | 2791 | 822 | 3.03 / 253.69 | 6 | 30 |
4 | 13 | 949.96 | 20 | 14.85 | 1792 | 532 | 3.56 / 254.22 | 6 | 38 |
5 | 13 | 260.48 | 20 | 15.06 | 781 | 235 | 3.80 / 254.45 | 6 | 36 |
6 | 8 | -0.12 | 319 | 15.05 | 386 | 1853 | 5.65 / 256.31 | 6 | 145 |
Average= | 5.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 39 | 15.02 | 530 | 310 | 0.31 / 245.31 | 6 | 9 |
2 | 7 | 2022.40 | 40 | 14.71 | 3244 | 1909 | 2.22 / 247.22 | 9 | 22 |
3 | 13 | 1593.92 | 20 | 14.74 | 2690 | 793 | 3.01 / 248.02 | 6 | 30 |
4 | 13 | 921.92 | 20 | 14.86 | 1753 | 521 | 3.53 / 248.54 | 6 | 37 |
5 | 13 | 334.68 | 20 | 15.04 | 888 | 267 | 3.80 / 248.80 | 6 | 35 |
6 | 8 | 0.12 | 319 | 15.05 | 386 | 1853 | 5.65 / 250.66 | 6 | 145 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 39 | 15.02 | 522 | 306 | 0.31 / 239.72 | 6 | 9 |
2 | 7 | 2010.84 | 40 | 14.71 | 3228 | 1899 | 2.21 / 241.62 | 9 | 21 |
3 | 13 | 1549.56 | 20 | 14.76 | 2615 | 772 | 2.98 / 242.39 | 6 | 29 |
4 | 13 | 960.32 | 20 | 14.86 | 1800 | 535 | 3.51 / 242.92 | 6 | 36 |
5 | 13 | 254.32 | 20 | 15.08 | 762 | 230 | 3.74 / 243.15 | 6 | 35 |
6 | 8 | -0.12 | 319 | 15.06 | 385 | 1850 | 5.59 / 245.00 | 6 | 162 |
Average= | 5.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 39 | 15.03 | 531 | 311 | 0.31 / 234.10 | 6 | 10 |
2 | 7 | 2009.44 | 40 | 14.72 | 3227 | 1900 | 2.21 / 236.00 | 10 | 24 |
3 | 13 | 1492.04 | 20 | 14.76 | 2553 | 754 | 2.96 / 236.75 | 6 | 31 |
4 | 13 | 1058.68 | 20 | 14.83 | 1946 | 577 | 3.54 / 237.33 | 6 | 36 |
5 | 13 | 238.16 | 20 | 15.08 | 741 | 223 | 3.77 / 237.55 | 6 | 33 |
6 | 8 | 0.12 | 319 | 15.06 | 387 | 1859 | 5.62 / 239.41 | 6 | 173 |
Average= | 5.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 38 | 15.03 | 547 | 312 | 0.31 / 228.60 | 6 | 11 |
2 | 7 | 2011.64 | 40 | 14.72 | 3217 | 1894 | 2.21 / 230.50 | 11 | 23 |
3 | 13 | 1559.56 | 20 | 14.76 | 2616 | 772 | 2.98 / 231.27 | 6 | 30 |
4 | 13 | 889.24 | 20 | 14.89 | 1702 | 507 | 3.49 / 231.78 | 6 | 37 |
5 | 13 | 111.00 | 20 | 15.14 | 549 | 166 | 3.65 / 231.94 | 6 | 32 |
6 | 8 | 0.00 | 317 | 15.08 | 386 | 1845 | 5.50 / 233.79 | 6 | -99 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 39 | 15.04 | 534 | 313 | 0.31 / 223.01 | 6 | 10 |
2 | 7 | 2017.92 | 40 | 14.71 | 3245 | 1909 | 2.22 / 224.92 | 10 | 24 |
3 | 13 | 1481.56 | 20 | 14.78 | 2540 | 751 | 2.97 / 225.67 | 6 | 31 |
4 | 13 | 931.32 | 20 | 14.87 | 1771 | 527 | 3.50 / 226.19 | 6 | 37 |
5 | 13 | 238.84 | 20 | 15.09 | 749 | 226 | 3.73 / 226.42 | 6 | 35 |
6 | 8 | 0.20 | 319 | 15.07 | 389 | 1870 | 5.60 / 228.29 | 6 | 153 |
Average= | 5.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 38 | 15.03 | 557 | 318 | 0.32 / 217.37 | 6 | 10 |
2 | 7 | 2015.92 | 40 | 14.71 | 3225 | 1898 | 2.22 / 219.27 | 10 | 23 |
3 | 13 | 1557.20 | 20 | 14.76 | 2632 | 777 | 2.99 / 220.05 | 6 | 30 |
4 | 13 | 1064.44 | 20 | 14.84 | 1955 | 580 | 3.57 / 220.63 | 6 | 36 |
5 | 13 | 220.44 | 20 | 15.11 | 720 | 218 | 3.79 / 220.85 | 6 | 34 |
6 | 8 | -0.04 | 319 | 15.08 | 384 | 1847 | 5.64 / 222.69 | 6 | 182 |
Average= | 5.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 38 | 15.04 | 546 | 312 | 0.31 / 211.79 | 6 | 10 |
2 | 7 | 2007.32 | 40 | 14.72 | 3230 | 1902 | 2.21 / 213.70 | 10 | 23 |
3 | 13 | 1457.32 | 20 | 14.79 | 2501 | 740 | 2.95 / 214.44 | 6 | 31 |
4 | 13 | 1002.72 | 20 | 14.87 | 1865 | 555 | 3.51 / 214.99 | 6 | 36 |
5 | 13 | 193.56 | 20 | 15.11 | 681 | 206 | 3.71 / 215.20 | 6 | 34 |
6 | 8 | 0.16 | 317 | 15.08 | 389 | 1860 | 5.57 / 217.06 | 6 | 176 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 38 | 15.05 | 548 | 313 | 0.31 / 206.12 | 6 | 9 |
2 | 7 | 2006.36 | 40 | 14.73 | 3206 | 1889 | 2.20 / 208.01 | 9 | 22 |
3 | 13 | 1656.80 | 20 | 14.76 | 2755 | 813 | 3.02 / 208.82 | 6 | 30 |
4 | 13 | 952.12 | 20 | 14.88 | 1799 | 535 | 3.55 / 209.36 | 6 | 36 |
5 | 13 | 262.44 | 20 | 15.09 | 787 | 238 | 3.79 / 209.60 | 6 | 35 |
6 | 8 | 0.08 | 319 | 15.09 | 392 | 1887 | 5.68 / 211.48 | 6 | -99 |
Average= | 5.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 38 | 15.04 | 545 | 311 | 0.31 / 200.46 | 6 | 9 |
2 | 7 | 2007.12 | 40 | 14.73 | 3233 | 1905 | 2.22 / 202.36 | 9 | 23 |
3 | 13 | 1483.72 | 20 | 14.80 | 2527 | 748 | 2.96 / 203.11 | 6 | 31 |
4 | 13 | 1017.48 | 20 | 14.87 | 1877 | 558 | 3.52 / 203.67 | 6 | 37 |
5 | 13 | 312.36 | 20 | 15.07 | 858 | 259 | 3.78 / 203.93 | 6 | 37 |
6 | 8 | 0.12 | 321 | 15.08 | 388 | 1878 | 5.66 / 205.81 | 6 | 175 |
Average= | 5.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 38 | 15.05 | 539 | 308 | 0.31 / 194.86 | 6 | 9 |
2 | 7 | 2010.36 | 40 | 14.72 | 3245 | 1911 | 2.22 / 196.78 | 9 | 23 |
3 | 13 | 1479.40 | 20 | 14.80 | 2530 | 749 | 2.97 / 197.52 | 6 | 31 |
4 | 13 | 1012.84 | 20 | 14.87 | 1878 | 559 | 3.53 / 198.08 | 6 | 37 |
5 | 13 | 179.40 | 20 | 15.13 | 660 | 200 | 3.73 / 198.28 | 6 | 34 |
6 | 8 | -0.20 | 317 | 15.09 | 390 | 1866 | 5.59 / 200.15 | 6 | 234 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 38 | 15.05 | 534 | 305 | 0.31 / 189.32 | 6 | 9 |
2 | 7 | 2007.40 | 40 | 14.73 | 3229 | 1903 | 2.21 / 191.22 | 9 | 24 |
3 | 13 | 1558.60 | 20 | 14.79 | 2643 | 782 | 2.99 / 192.01 | 6 | 30 |
4 | 13 | 883.44 | 20 | 14.92 | 1704 | 508 | 3.50 / 192.51 | 6 | 37 |
5 | 13 | 115.84 | 20 | 15.16 | 564 | 171 | 3.67 / 192.68 | 6 | 32 |
6 | 8 | 0.20 | 317 | 15.10 | 391 | 1872 | 5.54 / 194.56 | 6 | -99 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 38 | 15.06 | 538 | 308 | 0.31 / 183.68 | 6 | 8 |
2 | 7 | 2019.44 | 40 | 14.73 | 3231 | 1904 | 2.21 / 185.58 | 8 | 24 |
3 | 13 | 1565.00 | 20 | 14.78 | 2645 | 782 | 2.99 / 186.37 | 6 | 30 |
4 | 13 | 974.60 | 20 | 14.89 | 1819 | 542 | 3.54 / 186.91 | 6 | 36 |
5 | 13 | 247.48 | 20 | 15.11 | 760 | 230 | 3.76 / 187.14 | 6 | 35 |
6 | 8 | 0.12 | 319 | 15.10 | 390 | 1879 | 5.64 / 189.02 | 6 | 234 |
Average= | 5.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 38 | 15.11 | 538 | 309 | 0.31 / 178.10 | 6 | 9 |
2 | 7 | 2006.24 | 40 | 14.73 | 3240 | 1909 | 2.22 / 180.01 | 9 | 24 |
3 | 13 | 1567.08 | 20 | 14.78 | 2660 | 786 | 3.00 / 180.80 | 6 | 30 |
4 | 13 | 869.72 | 20 | 14.92 | 1675 | 500 | 3.50 / 181.30 | 6 | 37 |
5 | 13 | 175.44 | 20 | 15.14 | 657 | 199 | 3.70 / 181.50 | 6 | 33 |
6 | 8 | 0.12 | 317 | 15.10 | 392 | 1876 | 5.58 / 183.37 | 6 | 168 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 39 | 15.07 | 525 | 309 | 0.31 / 173.39 | 6 | 8 |
2 | 7 | 1212.48 | 40 | 15.02 | 2136 | 1283 | 1.59 / 174.68 | 8 | 32 |
3 | 13 | 1163.40 | 20 | 14.99 | 2090 | 627 | 2.22 / 175.30 | 6 | 34 |
4 | 13 | 854.88 | 20 | 15.02 | 1661 | 499 | 2.72 / 175.80 | 6 | 38 |
5 | 13 | 106.72 | 20 | 15.22 | 553 | 168 | 2.89 / 175.97 | 6 | 32 |
6 | 8 | -0.12 | 310 | 15.16 | 388 | 1823 | 4.71 / 177.79 | 6 | 183 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 39 | 15.08 | 543 | 319 | 0.32 / 167.64 | 6 | 8 |
2 | 7 | 2004.00 | 40 | 14.74 | 3233 | 1906 | 2.23 / 169.54 | 8 | 24 |
3 | 13 | 1680.44 | 20 | 14.77 | 2806 | 829 | 3.05 / 170.37 | 6 | 29 |
4 | 13 | 1085.60 | 20 | 14.87 | 1988 | 591 | 3.65 / 170.96 | 6 | 36 |
5 | 13 | 370.00 | 20 | 15.08 | 941 | 284 | 3.93 / 171.25 | 6 | 36 |
6 | 8 | 0.00 | 314 | 15.11 | 387 | 1836 | 5.77 / 173.08 | 6 | 131 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 39 | 15.13 | 534 | 315 | 0.32 / 161.83 | 6 | 7 |
2 | 7 | 2008.60 | 40 | 14.75 | 3223 | 1902 | 2.22 / 163.73 | 7 | 23 |
3 | 13 | 1700.60 | 20 | 14.76 | 2835 | 837 | 3.05 / 164.57 | 6 | 29 |
4 | 13 | 1077.64 | 20 | 14.88 | 1969 | 586 | 3.64 / 165.15 | 6 | 35 |
5 | 13 | 454.44 | 20 | 15.06 | 1060 | 319 | 3.96 / 165.47 | 6 | 37 |
6 | 8 | -0.04 | 317 | 15.11 | 385 | 1844 | 5.80 / 167.32 | 6 | 167 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 39 | 15.14 | 510 | 301 | 0.30 / 157.35 | 6 | 7 |
2 | 7 | 1035.24 | 40 | 15.10 | 1872 | 1131 | 1.43 / 158.48 | 7 | 32 |
3 | 13 | 1029.20 | 20 | 15.06 | 1889 | 569 | 2.00 / 159.05 | 6 | 34 |
4 | 13 | 823.76 | 20 | 15.06 | 1607 | 484 | 2.48 / 159.54 | 6 | 36 |
5 | 13 | 180.68 | 20 | 15.22 | 659 | 201 | 2.69 / 159.74 | 6 | 31 |
6 | 8 | -0.28 | 306 | 15.18 | 383 | 1779 | 4.46 / 161.52 | 6 | 204 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 39 | 15.10 | 517 | 304 | 0.30 / 152.99 | 6 | 7 |
2 | 7 | 1044.28 | 40 | 15.10 | 1904 | 1150 | 1.45 / 154.14 | 14 | 32 |
3 | 13 | 1044.00 | 20 | 15.06 | 1919 | 578 | 2.03 / 154.72 | 6 | 33 |
4 | 13 | 719.00 | 20 | 15.09 | 1452 | 438 | 2.47 / 155.16 | 6 | 36 |
5 | 13 | 42.68 | 20 | 15.27 | 442 | 135 | 2.61 / 155.29 | 6 | 29 |
6 | 8 | 0.20 | 304 | 15.19 | 381 | 1759 | 4.37 / 157.05 | 6 | 178 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 39 | 15.10 | 502 | 296 | 0.30 / 147.79 | 6 | 7 |
2 | 7 | 1729.64 | 40 | 14.84 | 2840 | 1686 | 1.98 / 149.47 | 7 | 28 |
3 | 13 | 1429.56 | 20 | 14.87 | 2464 | 733 | 2.71 / 150.21 | 6 | 33 |
4 | 13 | 973.60 | 20 | 14.93 | 1823 | 544 | 3.26 / 150.75 | 6 | 38 |
5 | 13 | 75.52 | 20 | 15.21 | 493 | 150 | 3.41 / 150.90 | 6 | 28 |
6 | 8 | 0.24 | 310 | 15.15 | 380 | 1785 | 5.19 / 152.69 | 6 | 151 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 39 | 15.10 | 520 | 306 | 0.31 / 142.23 | 6 | 7 |
2 | 7 | 2009.92 | 40 | 14.75 | 3240 | 1912 | 2.22 / 144.14 | 7 | 23 |
3 | 13 | 1549.32 | 20 | 14.82 | 2622 | 777 | 2.99 / 144.92 | 6 | 31 |
4 | 13 | 883.76 | 20 | 14.95 | 1695 | 507 | 3.50 / 145.43 | 6 | 37 |
5 | 13 | 300.72 | 20 | 15.12 | 830 | 251 | 3.75 / 145.68 | 6 | 35 |
6 | 8 | -0.08 | 314 | 15.13 | 382 | 1815 | 5.57 / 147.49 | 6 | 210 |
Average= | 5.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 39 | 15.11 | 525 | 309 | 0.31 / 136.52 | 6 | 7 |
2 | 7 | 2004.72 | 40 | 14.76 | 3230 | 1907 | 2.22 / 138.43 | 7 | 23 |
3 | 13 | 1669.60 | 20 | 14.80 | 2797 | 828 | 3.04 / 139.26 | 6 | 30 |
4 | 13 | 1063.76 | 20 | 14.90 | 1953 | 582 | 3.63 / 139.84 | 6 | 36 |
5 | 13 | 356.08 | 20 | 15.11 | 921 | 278 | 3.90 / 140.12 | 6 | 35 |
6 | 8 | -0.08 | 317 | 15.13 | 377 | 1808 | 5.71 / 141.92 | 6 | -99 |
Average= | 5.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 39 | 15.12 | 520 | 307 | 0.31 / 130.95 | 6 | 7 |
2 | 7 | 2014.72 | 40 | 14.75 | 3248 | 1916 | 2.22 / 132.86 | 7 | 23 |
3 | 13 | 1591.40 | 20 | 14.81 | 2690 | 797 | 3.02 / 133.66 | 6 | 31 |
4 | 13 | 1009.32 | 20 | 14.91 | 1876 | 559 | 3.58 / 134.22 | 6 | 36 |
5 | 13 | 200.44 | 20 | 15.16 | 676 | 205 | 3.78 / 134.42 | 6 | 31 |
6 | 8 | -0.04 | 314 | 15.14 | 376 | 1787 | 5.57 / 136.21 | 6 | -99 |
Average= | 5.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 39 | 15.11 | 532 | 314 | 0.31 / 125.47 | 6 | 7 |
2 | 7 | 2008.40 | 40 | 14.77 | 3221 | 1903 | 2.22 / 127.38 | 7 | 23 |
3 | 13 | 1467.60 | 20 | 14.85 | 2486 | 738 | 2.95 / 128.11 | 6 | 32 |
4 | 13 | 1004.84 | 20 | 14.92 | 1871 | 558 | 3.51 / 128.67 | 6 | 37 |
5 | 13 | 179.08 | 20 | 15.17 | 649 | 197 | 3.71 / 128.87 | 6 | 30 |
6 | 8 | 0.16 | 312 | 15.14 | 375 | 1771 | 5.48 / 130.64 | 6 | -99 |
Average= | 5.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 39 | 15.11 | 523 | 308 | 0.31 / 119.93 | 6 | 6 |
2 | 7 | 2014.16 | 40 | 14.77 | 3232 | 1909 | 2.22 / 121.84 | 6 | 22 |
3 | 13 | 1554.48 | 20 | 14.83 | 2643 | 784 | 3.00 / 122.62 | 6 | 30 |
4 | 13 | 1000.56 | 20 | 14.93 | 1867 | 557 | 3.56 / 123.18 | 6 | 36 |
5 | 13 | 207.76 | 20 | 15.17 | 695 | 211 | 3.77 / 123.39 | 6 | 31 |
6 | 8 | -0.04 | 312 | 15.15 | 374 | 1768 | 5.54 / 125.16 | 6 | 170 |
Average= | 5.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 39 | 15.11 | 517 | 305 | 0.30 / 114.40 | 6 | 7 |
2 | 7 | 2016.32 | 40 | 14.77 | 3246 | 1918 | 2.22 / 116.32 | 7 | 22 |
3 | 13 | 1571.52 | 20 | 14.83 | 2647 | 785 | 3.01 / 117.10 | 6 | 30 |
4 | 13 | 893.20 | 20 | 14.96 | 1708 | 511 | 3.52 / 117.62 | 6 | 37 |
5 | 13 | 291.04 | 20 | 15.14 | 818 | 248 | 3.77 / 117.86 | 6 | 33 |
6 | 8 | 0.16 | 312 | 15.15 | 372 | 1758 | 5.52 / 119.62 | 6 | 166 |
Average= | 5.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 39 | 15.14 | 524 | 309 | 0.31 / 108.90 | 6 | 7 |
2 | 7 | 2010.68 | 40 | 14.78 | 3227 | 1908 | 2.22 / 110.80 | 7 | 22 |
3 | 13 | 1571.44 | 20 | 14.83 | 2650 | 786 | 3.00 / 111.59 | 6 | 30 |
4 | 13 | 1000.96 | 20 | 14.93 | 1862 | 556 | 3.56 / 112.15 | 6 | 37 |
5 | 13 | 181.68 | 20 | 15.18 | 648 | 197 | 3.76 / 112.34 | 6 | 30 |
6 | 8 | 0.04 | 312 | 15.15 | 371 | 1754 | 5.51 / 114.10 | 6 | -99 |
Average= | 5.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 38 | 15.12 | 523 | 300 | 0.30 / 103.96 | 6 | 7 |
2 | 7 | 1419.36 | 40 | 14.98 | 2414 | 1446 | 1.75 / 105.40 | 19 | 29 |
3 | 13 | 1342.04 | 20 | 14.96 | 2338 | 700 | 2.45 / 106.10 | 6 | 32 |
4 | 13 | 901.84 | 20 | 15.02 | 1721 | 517 | 2.96 / 106.62 | 6 | 38 |
5 | 13 | 165.12 | 20 | 15.23 | 629 | 192 | 3.16 / 106.81 | 6 | 31 |
6 | 8 | 0.04 | 310 | 15.19 | 377 | 1775 | 4.93 / 108.59 | 6 | -99 |
Average= | 5.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 38 | 15.13 | 514 | 296 | 0.30 / 98.41 | 6 | 7 |
2 | 7 | 2006.92 | 40 | 14.79 | 3233 | 1913 | 2.21 / 100.33 | 7 | 22 |
3 | 13 | 1467.60 | 20 | 14.86 | 2513 | 747 | 2.96 / 101.07 | 6 | 31 |
4 | 13 | 898.04 | 20 | 14.97 | 1718 | 514 | 3.47 / 101.59 | 6 | 37 |
5 | 13 | 425.20 | 20 | 15.10 | 1017 | 307 | 3.78 / 101.89 | 6 | 36 |
6 | 8 | 0.04 | 312 | 15.15 | 373 | 1763 | 5.54 / 103.66 | 6 | 190 |
Average= | 5.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 38 | 15.13 | 505 | 290 | 0.29 / 92.93 | 6 | 7 |
2 | 7 | 2017.28 | 40 | 14.78 | 3242 | 1917 | 2.21 / 94.85 | 7 | 22 |
3 | 13 | 1575.56 | 20 | 14.84 | 2660 | 789 | 3.00 / 95.64 | 6 | 30 |
4 | 13 | 896.44 | 20 | 14.96 | 1719 | 514 | 3.51 / 96.15 | 6 | 37 |
5 | 13 | 112.08 | 20 | 15.21 | 548 | 167 | 3.68 / 96.32 | 6 | 30 |
6 | 8 | -0.08 | 314 | 15.16 | 378 | 1799 | 5.48 / 98.12 | 6 | -99 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 38 | 15.13 | 513 | 295 | 0.29 / 87.45 | 6 | 7 |
2 | 7 | 2004.72 | 40 | 14.79 | 3233 | 1913 | 2.21 / 89.36 | 7 | 22 |
3 | 13 | 1381.00 | 20 | 14.89 | 2394 | 713 | 2.92 / 90.07 | 6 | 32 |
4 | 13 | 955.88 | 20 | 14.95 | 1804 | 539 | 3.46 / 90.61 | 6 | 37 |
5 | 13 | 247.20 | 20 | 15.17 | 756 | 229 | 3.69 / 90.84 | 6 | 32 |
6 | 8 | -0.08 | 314 | 15.16 | 378 | 1799 | 5.49 / 92.64 | 6 | -99 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 38 | 15.13 | 521 | 300 | 0.30 / 81.89 | 6 | 7 |
2 | 7 | 2017.96 | 40 | 14.78 | 3256 | 1925 | 2.22 / 83.82 | 12 | 22 |
3 | 13 | 1539.64 | 20 | 14.86 | 2605 | 774 | 3.00 / 84.59 | 6 | 29 |
4 | 13 | 975.00 | 20 | 14.96 | 1824 | 546 | 3.54 / 85.14 | 6 | 37 |
5 | 13 | 225.40 | 20 | 15.18 | 724 | 220 | 3.76 / 85.36 | 6 | 34 |
6 | 8 | 0.24 | 314 | 15.16 | 377 | 1795 | 5.56 / 87.15 | 6 | -99 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 38 | 15.12 | 532 | 306 | 0.31 / 76.28 | 6 | 8 |
2 | 7 | 2015.12 | 40 | 14.80 | 3241 | 1919 | 2.22 / 78.19 | 8 | 22 |
3 | 13 | 1475.40 | 20 | 14.87 | 2523 | 750 | 2.97 / 78.95 | 6 | 30 |
4 | 13 | 1010.40 | 20 | 14.95 | 1874 | 560 | 3.54 / 79.51 | 6 | 37 |
5 | 13 | 316.04 | 20 | 15.15 | 856 | 259 | 3.79 / 79.76 | 6 | 36 |
6 | 8 | -0.08 | 314 | 15.16 | 384 | 1828 | 5.62 / 81.59 | 6 | 145 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 38 | 15.13 | 517 | 297 | 0.30 / 70.69 | 6 | 8 |
2 | 7 | 2017.56 | 40 | 14.79 | 3250 | 1923 | 2.22 / 72.61 | 8 | 23 |
3 | 13 | 1470.52 | 20 | 14.88 | 2516 | 749 | 2.97 / 73.36 | 6 | 30 |
4 | 13 | 1016.88 | 20 | 14.95 | 1889 | 565 | 3.53 / 73.92 | 6 | 37 |
5 | 13 | 186.20 | 20 | 15.19 | 667 | 203 | 3.74 / 74.13 | 6 | 33 |
6 | 8 | 0.04 | 317 | 15.16 | 384 | 1845 | 5.58 / 75.97 | 6 | -99 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 38 | 15.14 | 523 | 301 | 0.30 / 65.18 | 6 | 9 |
2 | 7 | 2007.36 | 40 | 14.80 | 3243 | 1920 | 2.22 / 67.10 | 9 | 23 |
3 | 13 | 1563.52 | 20 | 14.87 | 2645 | 787 | 3.01 / 67.89 | 6 | 29 |
4 | 13 | 984.04 | 20 | 14.97 | 1837 | 550 | 3.56 / 68.44 | 6 | 37 |
5 | 13 | 149.68 | 20 | 15.21 | 600 | 183 | 3.74 / 68.62 | 6 | 31 |
6 | 8 | -0.08 | 314 | 15.17 | 371 | 1767 | 5.51 / 70.39 | 6 | -99 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 38 | 15.14 | 529 | 304 | 0.30 / 59.58 | 6 | 8 |
2 | 7 | 2004.96 | 40 | 14.81 | 3232 | 1915 | 2.22 / 61.49 | 8 | 23 |
3 | 13 | 1568.72 | 20 | 14.87 | 2645 | 787 | 3.01 / 62.28 | 6 | 29 |
4 | 13 | 989.32 | 20 | 14.97 | 1840 | 551 | 3.56 / 62.83 | 6 | 37 |
5 | 13 | 271.04 | 20 | 15.18 | 786 | 239 | 3.80 / 63.07 | 6 | 35 |
6 | 8 | 0.12 | 317 | 15.17 | 377 | 1813 | 5.61 / 64.88 | 6 | -99 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 38 | 15.14 | 521 | 300 | 0.30 / 54.05 | 6 | 9 |
2 | 7 | 2007.68 | 40 | 14.82 | 3246 | 1924 | 2.22 / 55.98 | 9 | 22 |
3 | 13 | 1477.40 | 20 | 14.89 | 2530 | 753 | 2.98 / 56.73 | 6 | 29 |
4 | 13 | 939.56 | 20 | 14.98 | 1777 | 532 | 3.51 / 57.26 | 6 | 36 |
5 | 13 | 246.00 | 20 | 15.18 | 749 | 227 | 3.74 / 57.49 | 6 | 33 |
6 | 8 | 0.12 | 314 | 15.17 | 374 | 1782 | 5.52 / 59.27 | 6 | -99 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 37 | 15.16 | 529 | 297 | 0.30 / 48.58 | 6 | 9 |
2 | 7 | 2010.32 | 40 | 14.82 | 3234 | 1917 | 2.21 / 50.50 | 9 | 23 |
3 | 13 | 1536.88 | 20 | 14.89 | 2592 | 772 | 2.99 / 51.27 | 6 | 29 |
4 | 13 | 940.32 | 20 | 14.98 | 1776 | 532 | 3.52 / 51.80 | 6 | 36 |
5 | 13 | 115.24 | 20 | 15.23 | 548 | 167 | 3.68 / 51.97 | 6 | 31 |
6 | 8 | 0.04 | 314 | 15.18 | 375 | 1787 | 5.47 / 53.76 | 6 | -99 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 37 | 15.13 | 538 | 301 | 0.30 / 43.17 | 6 | 10 |
2 | 7 | 2018.48 | 40 | 14.82 | 3246 | 1924 | 2.23 / 45.09 | 10 | 22 |
3 | 13 | 1462.68 | 20 | 14.90 | 2504 | 746 | 2.97 / 45.84 | 6 | 30 |
4 | 13 | 993.84 | 20 | 14.98 | 1843 | 552 | 3.52 / 46.39 | 6 | 36 |
5 | 13 | 81.52 | 20 | 15.25 | 491 | 150 | 3.67 / 46.54 | 6 | 30 |
6 | 8 | 0.16 | 312 | 15.19 | 368 | 1744 | 5.42 / 48.28 | 6 | -99 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 37 | 15.14 | 516 | 289 | 0.29 / 37.53 | 6 | 10 |
2 | 7 | 2008.52 | 40 | 14.83 | 3225 | 1913 | 2.20 / 39.45 | 12 | 22 |
3 | 13 | 1555.04 | 20 | 14.89 | 2609 | 777 | 2.98 / 40.22 | 6 | 28 |
4 | 13 | 973.64 | 20 | 14.99 | 1805 | 541 | 3.52 / 40.76 | 6 | 36 |
5 | 13 | 364.92 | 20 | 15.15 | 927 | 281 | 3.80 / 41.04 | 6 | 36 |
6 | 8 | 0.12 | 319 | 15.18 | 376 | 1821 | 5.62 / 42.87 | 6 | -99 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 36 | 15.14 | 536 | 292 | 0.29 / 32.01 | 6 | 11 |
2 | 3 | 1033.40 | 1 | 15.18 | 1905 | 29 | 0.32 / 32.04 | 6 | 22 |
3 | 7 | 2006.88 | 40 | 14.83 | 3236 | 1920 | 2.24 / 33.96 | 22 | 23 |
4 | 13 | 1538.68 | 20 | 14.90 | 2614 | 779 | 3.02 / 34.74 | 6 | 29 |
5 | 13 | 967.08 | 20 | 14.99 | 1810 | 543 | 3.56 / 35.29 | 6 | 36 |
6 | 13 | 148.00 | 20 | 15.23 | 596 | 182 | 3.74 / 35.47 | 6 | 31 |
7 | 8 | -0.08 | 317 | 15.19 | 369 | 1777 | 5.52 / 37.24 | 6 | -99 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 35 | 15.13 | 533 | 282 | 0.28 / 26.45 | 6 | 11 |
2 | 10 | 1005.68 | 3 | 15.11 | 1858 | 84 | 0.37 / 26.54 | 6 | 22 |
3 | 3 | 967.48 | -1 | 15.51 | 14 | 0 | 0.08 / 26.54 | 6 | 22 |
4 | 7 | 2014.36 | 41 | 14.83 | 3232 | 1965 | 2.33 / 28.50 | 22 | 22 |
5 | 13 | 1450.76 | 20 | 14.92 | 2474 | 738 | 3.07 / 29.24 | 6 | 30 |
6 | 13 | 890.72 | 20 | 15.01 | 1683 | 505 | 3.58 / 29.75 | 6 | 37 |
7 | 13 | 101.92 | 20 | 15.24 | 529 | 161 | 3.74 / 29.91 | 6 | 32 |
8 | 8 | 0.24 | 317 | 15.19 | 377 | 1815 | 5.55 / 31.72 | 6 | 226 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 31 | 15.14 | 524 | 246 | 0.25 / 20.84 | 6 | 11 |
2 | 10 | 1022.96 | 5 | 15.08 | 1880 | 142 | 0.39 / 20.99 | 6 | 22 |
3 | 3 | 1033.08 | 1 | 15.17 | 1892 | 29 | 0.42 / 21.01 | 6 | 19 |
4 | 7 | 2010.64 | 40 | 14.85 | 3249 | 1930 | 2.35 / 22.94 | 19 | 22 |
5 | 13 | 1464.36 | 20 | 14.92 | 2500 | 746 | 3.09 / 23.69 | 6 | 30 |
6 | 13 | 898.08 | 20 | 15.01 | 1712 | 514 | 3.61 / 24.20 | 6 | 37 |
7 | 13 | 130.72 | 20 | 15.23 | 573 | 175 | 3.78 / 24.38 | 6 | 34 |
8 | 8 | 0.08 | 319 | 15.19 | 370 | 1793 | 5.57 / 26.17 | 6 | 183 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 36 | 15.14 | 527 | 287 | 0.29 / 15.89 | 6 | 11 |
2 | 7 | 1518.76 | 40 | 14.98 | 2565 | 1537 | 1.82 / 17.43 | 11 | 26 |
3 | 13 | 1424.96 | 20 | 14.97 | 2449 | 733 | 2.56 / 18.16 | 6 | 29 |
4 | 13 | 843.04 | 20 | 15.06 | 1623 | 489 | 3.05 / 18.65 | 6 | 39 |
5 | 13 | 28.88 | 20 | 15.28 | 422 | 129 | 3.18 / 18.78 | 6 | 32 |
6 | 8 | 0.16 | 319 | 15.20 | 375 | 1818 | 4.99 / 20.60 | 6 | -99 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 35 | 15.14 | 522 | 277 | 0.28 / 10.85 | 6 | 11 |
2 | 3 | 1030.96 | 1 | 15.16 | 1916 | 29 | 0.31 / 10.88 | 6 | 16 |
3 | 7 | 1511.08 | 40 | 14.98 | 2561 | 1535 | 1.84 / 12.41 | 16 | 26 |
4 | 13 | 1424.44 | 20 | 14.97 | 2446 | 732 | 2.57 / 13.14 | 6 | 29 |
5 | 13 | 830.88 | 20 | 15.06 | 1623 | 489 | 3.06 / 13.63 | 6 | 38 |
6 | 13 | 96.76 | 20 | 15.25 | 527 | 161 | 3.22 / 13.79 | 6 | 34 |
7 | 8 | -0.08 | 321 | 15.20 | 371 | 1810 | 5.03 / 15.60 | 6 | -99 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 31 | 15.19 | 524 | 247 | 0.25 / 5.78 | 6 | 11 |
2 | 10 | 1032.48 | 5 | 15.11 | 1881 | 142 | 0.39 / 5.92 | 6 | 21 |
3 | 7 | 1527.08 | 40 | 14.98 | 2574 | 1542 | 1.93 / 7.46 | 6 | 26 |
4 | 13 | 1324.28 | 20 | 14.99 | 2302 | 690 | 2.62 / 8.15 | 6 | 31 |
5 | 13 | 884.56 | 20 | 15.04 | 1689 | 508 | 3.13 / 8.66 | 6 | 38 |
6 | 13 | 60.84 | 20 | 15.26 | 465 | 142 | 3.27 / 8.80 | 6 | 33 |
7 | 8 | 0.12 | 321 | 15.20 | 363 | 1771 | 5.04 / 10.57 | 6 | -99 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 31 | 15.35 | 494 | 235 | 0.24 / 2.40 | 6 | 10 |
2 | 10 | 1027.36 | 5 | 15.17 | 1870 | 142 | 0.38 / 2.54 | 6 | 20 |
3 | 7 | 1002.28 | 40 | 15.10 | 1833 | 1107 | 1.48 / 3.64 | 20 | 35 |
4 | 13 | 48.68 | 20 | 15.33 | 437 | 134 | 1.62 / 3.78 | 6 | 34 |
5 | 8 | 0.16 | 317 | 15.26 | 362 | 1751 | 3.37 / 5.53 | 6 | 188 |
Average= | 2.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 136.92 | 30 | 15.54 | 506 | 236 | 0.24 / 0.24 | 6 | 9 |
2 | 7 | 151.08 | 40 | 15.51 | 528 | 328 | 0.56 / 0.56 | 9 | 11 |
3 | 13 | 19.84 | 20 | 15.51 | 348 | 108 | 0.67 / 0.67 | 6 | 13 |
4 | 8 | 0.08 | 310 | 15.44 | 311 | 1489 | 2.16 / 2.16 | 6 | -99 |
Average= | 2.16 (KJ/cycle) |