SIO Argo Site:
Pump Diagnostics Page   



Serial= 7727 WMO= 1902446

Return

←PreviousNext→

Cycle 96 GMT 19/11/2024 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 40 14.96 479 287 0.29 / 524.67 6 12
2 7 2008.56 40 14.65 2901 1700 1.99 / 526.37 12 29
3 13 1918.44 20 14.62 2793 817 2.80 / 527.18 5 32
4 13 1720.16 20 14.59 2567 749 3.55 / 527.93 5 36
5 13 1037.52 20 14.70 1746 513 4.07 / 528.44 5 43
6 13 377.80 20 14.93 887 265 4.33 / 528.71 5 41
7 8 0.08 285 14.98 353 1507 5.84 / 530.22 6 148
Average= 5.96
(KJ/cycle)

Cycle 95 GMT 10/11/2024 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 40 14.96 484 290 0.29 / 518.86 6 14
2 7 2003.64 40 14.66 2889 1694 1.98 / 520.55 14 31
3 13 1920.04 20 14.63 2797 818 2.80 / 521.37 5 32
4 13 1499.28 20 14.63 2324 680 3.48 / 522.05 5 38
5 13 1066.52 20 14.69 1789 526 4.01 / 522.58 5 44
6 13 414.04 20 14.91 926 276 4.28 / 522.85 5 45
7 8 0.00 291 14.97 350 1525 5.81 / 524.38 6 181
Average= 5.96
(KJ/cycle)

Cycle 94 GMT 31/10/2024 5: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 39 14.97 479 280 0.28 / 512.98 6 15
2 7 2006.96 41 14.66 2869 1724 2.00 / 514.70 15 30
3 13 1911.08 20 14.63 2777 813 2.82 / 515.52 5 33
4 13 1594.40 20 14.61 2431 710 3.53 / 516.23 5 37
5 13 1053.28 20 14.70 1768 520 4.05 / 516.75 5 44
6 13 388.60 20 14.92 906 270 4.32 / 517.02 5 44
7 8 0.04 289 14.97 359 1553 5.87 / 518.57 6 -99
Average= 5.96
(KJ/cycle)

Cycle 93 GMT 21/10/2024 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 39 14.97 488 285 0.28 / 507.17 6 19
2 7 2003.12 40 14.66 2879 1688 1.97 / 508.86 19 31
3 13 1919.32 20 14.63 2801 820 2.79 / 509.68 5 34
4 13 1607.88 20 14.62 2422 708 3.50 / 510.39 5 38
5 13 1163.92 20 14.67 1902 558 4.06 / 510.95 5 44
6 13 378.20 20 14.93 880 263 4.32 / 511.21 5 43
7 8 0.12 285 14.99 349 1491 5.81 / 512.70 6 138
Average= 5.96
(KJ/cycle)

Cycle 92 GMT 11/10/2024 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 39 14.98 482 282 0.28 / 501.50 6 13
2 7 2014.64 40 14.66 2903 1702 1.98 / 503.20 13 30
3 13 1921.44 20 14.65 2749 805 2.79 / 504.01 5 33
4 13 1484.52 20 14.64 2310 676 3.47 / 504.68 5 38
5 13 1052.84 20 14.70 1781 524 3.99 / 505.21 5 46
6 13 92.24 20 15.03 488 147 4.14 / 505.36 5 35
7 8 0.00 289 14.98 354 1533 5.67 / 506.89 5 168
Average= 5.96
(KJ/cycle)

Cycle 91 GMT 1/10/2024 14: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 39 14.96 494 288 0.29 / 495.80 6 14
2 7 2008.76 41 14.66 2878 1730 2.02 / 497.53 14 31
3 13 1932.64 20 14.62 2828 827 2.84 / 498.35 5 33
4 13 1424.24 20 14.64 2235 654 3.50 / 499.01 5 39
5 13 999.28 20 14.71 1707 502 4.00 / 499.51 5 43
6 13 240.00 20 14.98 696 209 4.21 / 499.72 5 41
7 8 0.04 285 14.99 351 1500 5.71 / 501.22 6 146
Average= 5.97
(KJ/cycle)

Cycle 90 GMT 21/ 9/2024 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 39 14.97 486 284 0.28 / 490.13 6 15
2 7 2015.08 40 14.65 2897 1698 1.98 / 491.83 15 31
3 13 1924.60 20 14.62 2824 826 2.81 / 492.65 5 35
4 13 1404.72 20 14.65 2212 648 3.46 / 493.30 5 40
5 13 883.84 20 14.75 1559 460 3.92 / 493.76 5 46
6 13 327.68 20 14.95 814 243 4.16 / 494.00 5 43
7 8 0.08 285 14.98 353 1507 5.67 / 495.51 6 143
Average= 5.97
(KJ/cycle)

Cycle 89 GMT 11/ 9/2024 19:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 39 14.98 480 280 0.28 / 484.40 6 13
2 7 2006.92 40 14.67 2881 1691 1.97 / 486.09 13 31
3 13 1925.92 20 14.63 2825 827 2.80 / 486.92 5 33
4 13 1516.72 20 14.63 2336 684 3.48 / 487.60 5 38
5 13 987.48 20 14.72 1689 497 3.98 / 488.10 5 43
6 13 334.00 20 14.94 820 245 4.22 / 488.34 5 43
7 8 0.00 285 14.98 352 1503 5.73 / 489.84 6 130
Average= 5.97
(KJ/cycle)

Cycle 88 GMT 1/ 9/2024 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 39 14.98 481 281 0.28 / 478.62 6 10
2 7 2004.00 40 14.67 2875 1687 1.97 / 480.31 10 30
3 13 1918.08 20 14.63 2826 827 2.79 / 481.13 5 32
4 13 1609.72 20 14.61 2442 714 3.51 / 481.85 5 36
5 13 1053.00 20 14.70 1774 522 4.03 / 482.37 5 44
6 13 298.00 20 14.96 774 232 4.26 / 482.60 5 44
7 8 0.16 287 14.98 353 1518 5.78 / 484.12 6 -99
Average= 5.98
(KJ/cycle)

Cycle 87 GMT 23/ 8/2024 1:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 40 15.00 471 283 0.28 / 472.94 6 13
2 7 2003.24 40 14.66 2883 1691 1.97 / 474.63 13 32
3 13 1913.32 20 14.65 2753 807 2.78 / 475.44 5 32
4 13 1601.04 20 14.62 2429 710 3.49 / 476.15 5 37
5 13 950.00 20 14.74 1638 483 3.97 / 476.63 5 43
6 13 306.28 20 14.96 778 233 4.21 / 476.86 5 40
7 8 0.08 285 14.99 345 1474 5.68 / 478.34 6 -99
Average= 5.98
(KJ/cycle)

Cycle 86 GMT 13/ 8/2024 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 40 14.98 470 282 0.28 / 467.34 6 11
2 7 2006.56 40 14.66 2911 1707 1.99 / 469.04 11 29
3 13 1923.56 20 14.63 2802 820 2.81 / 469.86 5 32
4 13 1516.92 20 14.63 2345 686 3.49 / 470.55 5 38
5 13 894.28 20 14.75 1578 466 3.96 / 471.01 5 44
6 13 172.04 20 15.01 595 179 4.14 / 471.19 5 36
7 13 14.32 20 15.06 370 111 4.25 / 471.31 6 33
8 8 0.12 261 14.99 346 1354 5.60 / 472.66 6 -99
Average= 5.98
(KJ/cycle)

Cycle 85 GMT 3/ 8/2024 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 40 14.99 479 287 0.29 / 461.64 6 10
2 7 2005.88 40 14.67 2879 1689 1.98 / 463.33 10 30
3 13 1919.24 20 14.63 2822 826 2.80 / 464.15 5 34
4 13 1612.72 20 14.61 2457 718 3.52 / 464.87 5 37
5 13 967.76 20 14.73 1666 491 4.01 / 465.36 5 45
6 13 332.48 20 14.96 814 244 4.25 / 465.61 5 39
7 8 -0.08 280 14.99 345 1448 5.70 / 467.05 6 147
Average= 5.99
(KJ/cycle)

Cycle 84 GMT 24/ 7/2024 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 40 14.99 482 289 0.29 / 455.98 6 11
2 7 2006.52 40 14.67 2894 1698 1.99 / 457.67 11 29
3 13 1923.24 20 14.63 2824 826 2.81 / 458.50 5 32
4 13 1505.96 20 14.63 2327 681 3.49 / 459.18 5 39
5 13 1080.80 20 14.69 1811 532 4.03 / 459.71 5 42
6 13 227.00 20 15.00 669 201 4.23 / 459.91 5 39
7 8 0.16 278 15.00 345 1439 5.67 / 461.35 6 -99
Average= 5.99
(KJ/cycle)

Cycle 83 GMT 14/ 7/2024 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 40 14.99 476 285 0.29 / 450.27 6 11
2 7 2004.60 40 14.68 2876 1689 1.97 / 451.96 11 28
3 13 1918.24 20 14.63 2828 827 2.80 / 452.79 5 34
4 13 1510.24 20 14.63 2332 682 3.48 / 453.47 5 40
5 13 1085.88 20 14.69 1817 534 4.02 / 454.00 5 43
6 13 320.84 20 14.96 798 239 4.26 / 454.24 5 41
7 8 -0.04 278 15.00 346 1443 5.70 / 455.69 6 -99
Average= 6.00
(KJ/cycle)

Cycle 82 GMT 4/ 7/2024 15:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 40 15.00 474 284 0.28 / 444.59 6 13
2 7 2007.28 41 14.67 2882 1733 2.02 / 446.32 13 29
3 13 1928.56 20 14.64 2806 822 2.84 / 447.14 5 33
4 13 1514.20 20 14.63 2332 682 3.52 / 447.83 5 38
5 13 1075.04 20 14.70 1800 529 4.05 / 448.36 5 43
6 13 206.56 20 15.01 638 192 4.24 / 448.55 5 38
7 8 0.04 278 15.01 345 1440 5.68 / 449.99 6 -99
Average= 6.00
(KJ/cycle)

Cycle 81 GMT 24/ 6/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 40 14.99 467 280 0.28 / 438.99 6 11
2 7 2004.04 40 14.67 2886 1694 1.97 / 440.69 11 29
3 13 1923.36 20 14.63 2806 821 2.79 / 441.51 5 33
4 13 1503.68 20 14.64 2316 678 3.47 / 442.19 5 38
5 13 970.88 20 14.74 1661 490 3.96 / 442.68 5 44
6 13 217.44 20 15.00 644 193 4.16 / 442.87 5 37
7 8 0.16 278 15.00 344 1434 5.59 / 444.30 6 -99
Average= 6.00
(KJ/cycle)

Cycle 80 GMT 14/ 6/2024 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 39 14.99 478 279 0.28 / 433.23 6 11
2 7 2005.36 41 14.66 2886 1735 2.01 / 434.97 11 29
3 13 1916.24 20 14.63 2812 823 2.84 / 435.79 5 34
4 13 1510.80 20 14.63 2333 683 3.52 / 436.47 5 39
5 13 1189.08 20 14.66 1948 571 4.09 / 437.04 5 41
6 13 301.12 20 14.97 766 229 4.32 / 437.27 5 38
7 8 0.28 278 15.00 346 1443 5.76 / 438.71 6 -99
Average= 6.01
(KJ/cycle)

Cycle 79 GMT 5/ 6/2024 0: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 39 14.98 476 278 0.28 / 427.64 6 9
2 7 2006.32 40 14.68 2888 1696 1.97 / 429.34 9 30
3 13 1923.12 20 14.64 2793 818 2.79 / 430.15 5 32
4 13 1507.32 20 14.63 2329 681 3.47 / 430.84 5 38
5 13 968.16 20 14.74 1663 490 3.96 / 431.33 5 43
6 13 221.28 20 15.00 654 196 4.16 / 431.52 5 36
7 8 -0.08 278 15.00 343 1430 5.59 / 432.95 6 148
Average= 6.01
(KJ/cycle)

Cycle 78 GMT 26/ 5/2024 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 39 14.98 476 278 0.28 / 421.92 6 11
2 7 2007.08 40 14.66 2887 1693 1.97 / 423.61 11 29
3 13 1924.52 20 14.64 2804 821 2.79 / 424.43 5 34
4 13 1606.08 20 14.62 2434 712 3.50 / 425.14 5 37
5 13 866.60 20 14.77 1542 456 3.96 / 425.60 5 46
6 13 431.56 20 14.91 959 286 4.25 / 425.88 5 43
7 8 0.16 280 14.99 352 1477 5.72 / 427.36 6 229
Average= 6.02
(KJ/cycle)

Cycle 77 GMT 16/ 5/2024 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 40 14.98 471 282 0.28 / 416.29 6 11
2 7 2006.04 40 14.67 2878 1689 1.97 / 417.98 11 29
3 13 1921.60 20 14.64 2799 820 2.79 / 418.80 5 34
4 13 1418.60 20 14.66 2205 647 3.44 / 419.44 5 38
5 13 1106.88 20 14.69 1836 539 3.98 / 419.98 5 43
6 13 222.04 20 15.00 655 196 4.17 / 420.18 5 38
7 8 0.00 282 15.00 345 1459 5.63 / 421.64 6 -99
Average= 6.02
(KJ/cycle)

Cycle 76 GMT 6/ 5/2024 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 40 14.99 479 287 0.29 / 410.57 6 11
2 7 2014.08 40 14.67 2904 1704 1.99 / 412.28 11 29
3 13 1924.20 20 14.64 2800 820 2.81 / 413.10 5 33
4 13 1400.48 20 14.66 2198 644 3.46 / 413.74 5 40
5 13 971.00 20 14.73 1667 491 3.95 / 414.23 5 44
6 13 419.36 20 14.91 943 281 4.23 / 414.51 5 43
7 8 -0.08 282 14.99 353 1492 5.72 / 416.01 6 -99
Average= 6.03
(KJ/cycle)

Cycle 75 GMT 26/ 4/2024 11:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 40 14.99 472 283 0.28 / 404.91 6 12
2 7 2006.24 41 14.66 2891 1738 2.02 / 406.65 12 31
3 13 1923.16 20 14.64 2798 819 2.84 / 407.47 5 33
4 13 1521.00 20 14.64 2310 676 3.52 / 408.14 5 40
5 13 983.32 20 14.73 1665 491 4.01 / 408.63 5 43
6 13 232.36 20 14.99 677 203 4.21 / 408.84 5 40
7 8 0.20 278 15.00 348 1451 5.66 / 410.29 6 143
Average= 6.03
(KJ/cycle)

Cycle 74 GMT 16/ 4/2024 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 40 14.98 481 288 0.29 / 399.13 6 12
2 7 2011.56 40 14.68 2886 1695 1.98 / 400.83 12 30
3 13 1916.80 20 14.65 2774 813 2.80 / 401.64 5 34
4 13 1718.00 20 14.60 2564 749 3.54 / 402.39 5 37
5 13 1171.44 20 14.67 1915 562 4.11 / 402.95 5 42
6 13 301.00 20 14.98 763 229 4.33 / 403.18 5 40
7 8 -0.04 280 15.00 344 1445 5.78 / 404.63 6 186
Average= 6.04
(KJ/cycle)

Cycle 73 GMT 6/ 4/2024 17:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 40 14.99 474 284 0.28 / 393.35 6 10
2 7 2005.36 41 14.67 2891 1739 2.02 / 395.09 10 30
3 13 1914.84 20 14.64 2793 818 2.84 / 395.91 5 34
4 13 1493.72 20 14.64 2301 674 3.51 / 396.58 5 39
5 13 1149.00 20 14.68 1880 552 4.07 / 397.13 5 42
6 13 355.48 20 14.95 839 251 4.32 / 397.38 5 43
7 8 0.12 282 15.00 346 1464 5.78 / 398.85 6 -99
Average= 6.04
(KJ/cycle)

Cycle 72 GMT 27/ 3/2024 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 39 15.00 472 276 0.28 / 387.62 6 10
2 3 1019.40 1 15.07 1725 26 0.30 / 387.65 5 32
3 7 2010.20 41 14.67 2886 1736 2.04 / 389.38 32 30
4 13 1921.80 20 14.63 2804 820 2.86 / 390.20 5 33
5 13 1510.40 20 14.64 2335 684 3.54 / 390.89 5 38
6 13 954.00 20 14.75 1640 484 4.03 / 391.37 5 43
7 13 311.04 20 14.97 777 233 4.26 / 391.60 5 39
8 13 38.52 20 15.06 400 120 4.38 / 391.73 6 35
9 8 0.08 259 15.00 345 1340 5.72 / 393.07 6 171
Average= 6.05
(KJ/cycle)

Cycle 71 GMT 17/ 3/2024 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 40 14.98 483 289 0.29 / 382.01 6 10
2 7 2004.76 40 14.67 2881 1691 1.98 / 383.70 10 29
3 13 1915.96 20 14.65 2782 815 2.80 / 384.52 5 32
4 13 1506.88 20 14.65 2311 677 3.47 / 385.19 5 38
5 13 893.76 20 14.77 1556 460 3.93 / 385.65 5 44
6 13 357.56 20 14.95 848 254 4.19 / 385.91 5 42
7 8 0.12 280 15.00 343 1441 5.63 / 387.35 6 190
Average= 6.05
(KJ/cycle)

Cycle 70 GMT 8/ 3/2024 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 40 15.00 468 281 0.28 / 376.36 6 9
2 7 2012.32 40 14.67 2886 1694 1.97 / 378.06 9 31
3 13 1922.92 20 14.64 2811 823 2.80 / 378.88 5 32
4 13 1412.72 20 14.66 2212 649 3.45 / 379.53 5 39
5 13 886.28 20 14.76 1567 463 3.91 / 379.99 5 45
6 13 346.16 20 14.94 843 252 4.16 / 380.24 5 42
7 8 -0.04 280 14.99 352 1477 5.64 / 381.72 6 175
Average= 6.06
(KJ/cycle)

Cycle 69 GMT 27/ 2/2024 4:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 39 15.00 451 264 0.26 / 370.69 6 9
2 3 1023.32 1 15.08 1730 26 0.29 / 370.72 5 36
3 7 2006.96 40 14.67 2884 1692 1.98 / 372.41 36 29
4 13 1924.80 20 14.64 2805 821 2.80 / 373.23 5 33
5 13 1510.68 20 14.64 2307 675 3.48 / 373.91 5 38
6 13 976.36 20 14.73 1657 488 3.97 / 374.40 5 44
7 13 335.24 20 14.96 816 244 4.21 / 374.64 5 39
8 8 0.04 278 15.00 346 1443 5.65 / 376.08 6 -99
Average= 6.07
(KJ/cycle)

Cycle 68 GMT 17/ 2/2024 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 39 15.00 467 273 0.27 / 365.02 6 8
2 7 2007.80 40 14.68 2890 1697 1.97 / 366.72 34 31
3 13 1928.60 20 14.64 2803 821 2.79 / 367.54 5 35
4 13 1513.32 20 14.65 2307 676 3.47 / 368.22 5 38
5 13 1083.60 20 14.71 1805 531 4.00 / 368.75 5 41
6 13 310.36 20 14.97 780 234 4.23 / 368.98 5 41
7 13 36.28 20 15.06 401 121 4.35 / 369.10 6 33
8 8 0.04 257 15.00 344 1326 5.68 / 370.43 6 155
Average= 6.07
(KJ/cycle)

Cycle 67 GMT 7/ 2/2024 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 39 15.00 468 274 0.27 / 359.49 6 8
2 7 2008.00 40 14.67 2889 1695 1.97 / 361.19 8 31
3 13 1923.00 20 14.65 2779 814 2.78 / 362.00 5 31
4 13 1496.56 20 14.64 2313 677 3.46 / 362.68 5 40
5 13 865.12 20 14.78 1537 454 3.91 / 363.14 5 43
6 13 134.12 20 15.03 538 162 4.08 / 363.30 5 44
7 8 0.24 279 15.00 347 1452 5.53 / 364.75 6 -99
Average= 6.08
(KJ/cycle)

Cycle 66 GMT 28/ 1/2024 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 39 14.99 473 277 0.28 / 353.99 6 10
2 7 2007.12 40 14.67 2879 1689 1.97 / 355.67 10 30
3 13 1926.92 20 14.64 2804 821 2.79 / 356.50 5 33
4 13 1415.88 20 14.67 2194 644 3.43 / 357.14 5 39
5 13 980.24 20 14.75 1650 487 3.92 / 357.63 5 44
6 13 120.20 20 15.04 515 155 4.07 / 357.78 5 37
7 8 -0.24 278 15.01 345 1440 5.51 / 359.22 6 -99
Average= 6.09
(KJ/cycle)

Cycle 65 GMT 18/ 1/2024 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 39 14.99 470 275 0.27 / 348.26 6 10
2 7 2007.40 40 14.68 2881 1692 1.97 / 349.95 10 31
3 13 1931.80 20 14.64 2818 825 2.79 / 350.78 5 34
4 13 1512.88 20 14.65 2329 682 3.47 / 351.46 5 39
5 13 970.00 20 14.74 1668 492 3.97 / 351.95 5 43
6 13 420.24 20 14.92 943 281 4.25 / 352.23 5 46
7 8 0.00 280 15.00 352 1478 5.73 / 353.71 6 218
Average= 6.10
(KJ/cycle)

Cycle 64 GMT 8/ 1/2024 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 39 15.00 469 274 0.27 / 342.59 6 10
2 7 2011.32 40 14.68 2898 1702 1.98 / 344.29 10 30
3 13 1932.68 20 14.64 2827 828 2.80 / 345.12 5 33
4 13 1427.60 20 14.66 2233 655 3.46 / 345.77 5 39
5 13 1000.80 20 14.73 1703 502 3.96 / 346.27 5 44
6 13 356.24 20 14.94 858 256 4.22 / 346.53 5 44
7 8 0.00 280 14.99 346 1452 5.67 / 347.98 6 141
Average= 6.10
(KJ/cycle)

Cycle 63 GMT 29/12/2023 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 39 14.99 471 275 0.28 / 337.03 6 11
2 7 2008.28 40 14.67 2896 1699 1.97 / 338.73 11 32
3 13 1922.84 20 14.64 2811 823 2.80 / 339.55 5 34
4 13 1511.88 20 14.65 2295 672 3.47 / 340.22 5 38
5 13 969.72 20 14.74 1658 489 3.96 / 340.71 5 44
6 13 124.28 20 15.04 524 158 4.12 / 340.87 5 40
7 13 25.84 20 15.06 391 118 4.23 / 340.99 6 36
8 8 0.12 255 15.00 347 1327 5.56 / 342.31 6 135
Average= 6.11
(KJ/cycle)

Cycle 62 GMT 20/12/2023 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 39 15.00 471 276 0.28 / 331.37 6 9
2 7 2006.76 40 14.68 2875 1688 1.96 / 333.06 9 32
3 13 1925.76 20 14.64 2810 823 2.79 / 333.88 5 35
4 13 1515.08 20 14.65 2316 679 3.47 / 334.56 5 37
5 13 973.20 20 14.74 1671 493 3.96 / 335.05 5 43
6 13 330.64 20 14.96 825 247 4.20 / 335.30 5 46
7 8 0.12 278 15.00 349 1455 5.66 / 336.75 6 -99
Average= 6.12
(KJ/cycle)

Cycle 61 GMT 10/12/2023 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 39 15.00 472 276 0.28 / 325.79 6 10
2 7 2012.28 40 14.68 2890 1697 1.97 / 327.48 10 31
3 13 1920.00 20 14.65 2773 812 2.79 / 328.30 5 33
4 13 1505.64 20 14.66 2334 684 3.47 / 328.98 5 39
5 13 868.52 20 14.78 1545 457 3.93 / 329.44 5 46
6 13 239.24 20 14.99 690 207 4.13 / 329.64 5 43
7 13 22.48 20 15.06 382 115 4.25 / 329.76 6 36
8 8 0.08 257 15.00 346 1334 5.58 / 331.09 6 152
Average= 6.13
(KJ/cycle)

Cycle 60 GMT 30/11/2023 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 39 14.98 482 282 0.28 / 320.20 6 11
2 7 2004.20 40 14.68 2880 1691 1.97 / 321.89 11 31
3 13 1915.20 20 14.65 2796 819 2.79 / 322.71 5 34
4 13 1401.28 20 14.67 2206 647 3.44 / 323.36 5 40
5 13 976.64 20 14.74 1680 495 3.93 / 323.85 5 45
6 13 211.92 20 15.01 656 197 4.13 / 324.05 5 43
7 8 0.20 278 15.00 350 1459 5.59 / 325.51 6 248
Average= 6.14
(KJ/cycle)

Cycle 59 GMT 20/11/2023 8:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 39 14.99 471 275 0.28 / 314.43 6 12
2 7 2007.76 40 14.68 2885 1694 1.97 / 316.12 12 31
3 13 1922.80 20 14.65 2804 822 2.79 / 316.94 5 35
4 13 1505.12 20 14.66 2317 679 3.47 / 317.62 5 39
5 13 961.32 20 14.75 1658 489 3.96 / 318.11 5 44
6 13 411.00 20 14.92 935 279 4.24 / 318.39 5 47
7 13 31.68 20 15.05 409 123 4.36 / 318.51 5 40
8 8 -0.04 261 14.98 360 1408 5.77 / 319.92 6 132
Average= 6.15
(KJ/cycle)

Cycle 58 GMT 10/11/2023 11: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 39 14.98 482 282 0.28 / 308.73 6 12
2 7 2012.44 40 14.69 2898 1703 1.98 / 310.43 12 31
3 13 1920.44 20 14.65 2776 813 2.80 / 311.25 5 32
4 13 1614.52 20 14.63 2458 719 3.52 / 311.96 5 38
5 13 961.84 20 14.75 1659 489 4.01 / 312.45 5 45
6 13 313.52 20 14.97 792 237 4.24 / 312.69 5 42
7 8 0.04 278 15.00 350 1459 5.70 / 314.15 6 137
Average= 6.16
(KJ/cycle)

Cycle 57 GMT 31/10/2023 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 39 14.99 477 279 0.28 / 303.05 6 14
2 7 2003.44 40 14.69 2885 1695 1.97 / 304.75 14 32
3 13 1910.72 20 14.67 2766 812 2.79 / 305.56 5 34
4 13 1600.52 20 14.65 2428 711 3.50 / 306.27 5 38
5 13 934.60 20 14.76 1619 478 3.97 / 306.75 5 45
6 13 287.52 20 14.98 759 227 4.20 / 306.98 5 43
7 8 -0.04 280 15.00 350 1470 5.67 / 308.45 6 155
Average= 6.17
(KJ/cycle)

Cycle 56 GMT 21/10/2023 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 39 14.98 485 283 0.28 / 297.35 6 15
2 7 2013.04 40 14.69 2894 1701 1.98 / 299.06 15 31
3 13 1925.40 20 14.66 2792 819 2.80 / 299.87 5 35
4 13 1520.32 20 14.66 2318 680 3.48 / 300.55 5 39
5 13 991.20 20 14.75 1693 499 3.98 / 301.05 5 44
6 13 342.16 20 14.96 830 248 4.23 / 301.30 5 44
7 8 0.12 280 15.00 351 1474 5.70 / 302.78 6 148
Average= 6.18
(KJ/cycle)

Cycle 55 GMT 11/10/2023 19:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 39 14.97 478 279 0.28 / 291.76 6 14
2 7 2008.92 40 14.69 2897 1702 1.98 / 293.46 14 30
3 13 1917.32 20 14.66 2799 821 2.80 / 294.28 5 32
4 13 1406.28 20 14.69 2188 643 3.44 / 294.93 5 38
5 13 884.68 20 14.79 1560 461 3.91 / 295.39 5 45
6 13 259.24 20 14.99 716 215 4.12 / 295.60 5 41
7 8 0.04 280 15.00 350 1470 5.59 / 297.07 6 132
Average= 6.19
(KJ/cycle)

Cycle 54 GMT 1/10/2023 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 39 14.98 483 282 0.28 / 286.15 6 14
2 7 2008.80 40 14.70 2873 1689 1.97 / 287.84 14 31
3 13 1915.32 20 14.66 2778 815 2.79 / 288.65 5 35
4 13 1394.00 20 14.68 2191 643 3.43 / 289.29 5 41
5 13 869.24 20 14.78 1540 455 3.88 / 289.75 5 46
6 13 337.76 20 14.96 830 248 4.13 / 290.00 5 44
7 8 0.04 280 15.00 353 1483 5.62 / 291.48 6 136
Average= 6.20
(KJ/cycle)

Cycle 53 GMT 22/ 9/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 39 14.99 484 283 0.28 / 280.42 6 14
2 7 2007.04 40 14.70 2871 1688 1.97 / 282.11 14 32
3 13 1916.48 20 14.67 2767 812 2.78 / 282.92 5 34
4 13 1596.48 20 14.64 2416 707 3.49 / 283.63 5 38
5 13 1026.96 20 14.74 1726 509 4.00 / 284.13 5 44
6 13 355.48 20 14.97 833 249 4.25 / 284.38 5 44
7 8 -0.08 282 15.00 350 1480 5.73 / 285.86 6 -99
Average= 6.21
(KJ/cycle)

Cycle 52 GMT 12/ 9/2023 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 39 15.02 488 286 0.29 / 274.71 6 13
2 7 2014.00 40 14.70 2899 1705 1.99 / 276.42 13 30
3 13 1925.36 20 14.67 2786 817 2.81 / 277.23 5 34
4 13 1508.48 20 14.67 2320 681 3.49 / 277.91 5 39
5 13 976.84 20 14.76 1668 492 3.98 / 278.41 5 44
6 13 437.44 20 14.93 957 286 4.27 / 278.69 5 44
7 8 0.12 278 15.01 346 1444 5.71 / 280.14 6 134
Average= 6.23
(KJ/cycle)

Cycle 51 GMT 2/ 9/2023 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 39 15.01 477 279 0.28 / 269.17 6 13
2 7 2005.72 40 14.71 2882 1696 1.97 / 270.87 13 31
3 13 1918.00 20 14.68 2768 813 2.79 / 271.68 5 33
4 13 1498.56 20 14.68 2296 674 3.46 / 272.36 5 39
5 13 950.68 20 14.79 1621 479 3.94 / 272.84 5 45
6 13 203.40 20 15.05 602 181 4.12 / 273.02 6 33
7 13 20.56 20 15.09 369 111 4.23 / 273.13 6 33
8 8 0.04 253 15.04 341 1298 5.53 / 274.43 6 173
Average= 6.24
(KJ/cycle)

Cycle 50 GMT 23/ 8/2023 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 39 15.02 474 278 0.28 / 263.60 6 13
2 7 2007.24 40 14.70 2898 1704 1.98 / 265.30 13 31
3 13 1923.52 20 14.68 2773 814 2.80 / 266.11 5 33
4 13 1489.96 20 14.69 2276 669 3.46 / 266.78 5 38
5 13 1052.52 20 14.75 1752 517 3.98 / 267.30 5 44
6 13 185.40 20 15.06 583 176 4.16 / 267.48 5 36
7 8 0.08 276 15.03 342 1419 5.58 / 268.89 6 192
Average= 6.25
(KJ/cycle)

Cycle 49 GMT 13/ 8/2023 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 39 15.04 472 277 0.28 / 257.97 6 13
2 7 2005.96 40 14.71 2882 1696 1.97 / 259.66 13 31
3 13 1917.80 20 14.67 2795 820 2.79 / 260.48 5 34
4 13 1497.88 20 14.69 2308 678 3.47 / 261.16 5 39
5 13 965.52 20 14.79 1662 492 3.96 / 261.65 5 44
6 13 313.32 20 15.01 778 234 4.20 / 261.89 5 39
7 8 0.16 276 15.04 345 1432 5.63 / 263.32 6 151
Average= 6.27
(KJ/cycle)

Cycle 48 GMT 3/ 8/2023 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 39 15.05 473 278 0.28 / 252.50 6 13
2 7 2012.80 40 14.72 2903 1709 1.99 / 254.21 21 32
3 13 1919.08 20 14.68 2803 823 2.81 / 255.03 5 33
4 13 1413.48 20 14.72 2193 646 3.46 / 255.68 5 40
5 13 884.08 20 14.82 1558 462 3.92 / 256.14 5 45
6 13 132.68 20 15.09 518 156 4.07 / 256.30 6 32
7 8 -0.04 272 15.06 340 1393 5.47 / 257.69 6 135
Average= 6.29
(KJ/cycle)

Cycle 47 GMT 24/ 7/2023 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 39 15.04 470 276 0.28 / 246.81 6 13
2 7 2003.28 40 14.73 2871 1692 1.97 / 248.50 13 32
3 13 1913.68 20 14.71 2789 821 2.79 / 249.32 5 33
4 13 1500.60 20 14.71 2318 682 3.47 / 250.00 5 38
5 13 1059.52 20 14.77 1773 524 3.99 / 250.53 5 44
6 13 392.32 20 15.00 893 268 4.26 / 250.79 5 42
7 8 0.16 276 15.05 344 1429 5.69 / 252.22 6 138
Average= 6.31
(KJ/cycle)

Cycle 46 GMT 14/ 7/2023 21:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 39 15.05 477 280 0.28 / 241.17 6 13
2 7 2013.72 40 14.72 2888 1700 1.98 / 242.87 13 32
3 13 1917.60 20 14.69 2794 821 2.80 / 243.69 5 35
4 13 1603.64 20 14.69 2432 715 3.52 / 244.41 5 38
5 13 935.24 20 14.82 1623 481 4.00 / 244.89 5 45
6 13 289.96 20 15.04 755 227 4.22 / 245.11 5 40
7 8 0.04 274 15.06 344 1419 5.64 / 246.53 6 133
Average= 6.32
(KJ/cycle)

Cycle 45 GMT 5/ 7/2023 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 39 15.07 486 286 0.29 / 235.53 6 13
2 7 2005.04 40 14.73 2892 1704 1.99 / 237.24 13 32
3 13 1920.60 20 14.70 2783 818 2.81 / 238.05 5 34
4 13 1489.32 20 14.72 2285 673 3.48 / 238.73 5 40
5 13 966.20 20 14.82 1645 488 3.97 / 239.21 5 45
6 13 318.36 20 15.03 789 237 4.21 / 239.45 5 40
7 8 0.08 276 15.07 346 1439 5.64 / 240.89 6 245
Average= 6.34
(KJ/cycle)

Cycle 44 GMT 25/ 6/2023 3: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 39 15.06 469 275 0.28 / 229.90 6 12
2 7 2005.76 41 14.73 2869 1733 2.01 / 231.63 12 30
3 13 1918.40 20 14.71 2803 825 2.83 / 232.46 5 34
4 13 1402.72 20 14.74 2197 648 3.48 / 233.11 5 41
5 13 972.48 20 14.82 1674 496 3.98 / 233.60 5 45
6 13 198.68 20 15.08 633 191 4.17 / 233.79 5 38
7 8 0.24 276 15.07 349 1452 5.62 / 235.25 6 160
Average= 6.36
(KJ/cycle)

Cycle 43 GMT 15/ 6/2023 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 39 15.05 471 276 0.28 / 224.24 6 12
2 7 2003.68 40 14.73 2889 1702 1.98 / 225.95 12 33
3 13 1917.52 20 14.70 2804 824 2.80 / 226.77 5 34
4 13 1489.72 20 14.73 2292 675 3.48 / 227.45 5 39
5 13 1051.68 20 14.80 1748 517 4.00 / 227.96 5 45
6 13 277.84 20 15.06 729 220 4.22 / 228.18 5 41
7 8 0.04 276 15.07 347 1443 5.66 / 229.63 6 -99
Average= 6.38
(KJ/cycle)

Cycle 42 GMT 5/ 6/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 39 15.07 475 279 0.28 / 218.72 6 11
2 7 2005.16 40 14.74 2882 1699 1.98 / 220.42 11 32
3 13 1922.12 20 14.72 2792 822 2.80 / 221.24 5 34
4 13 1398.12 20 14.76 2169 640 3.44 / 221.89 5 40
5 13 871.04 20 14.86 1525 453 3.89 / 222.34 5 44
6 13 237.68 20 15.08 673 203 4.10 / 222.54 5 40
7 8 0.00 276 15.07 343 1427 5.52 / 223.97 6 163
Average= 6.40
(KJ/cycle)

Cycle 41 GMT 26/ 5/2023 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 39 15.08 466 274 0.27 / 213.11 6 11
2 7 2005.44 40 14.74 2887 1702 1.98 / 214.81 11 32
3 13 1918.64 20 14.71 2803 825 2.80 / 215.64 5 35
4 13 1497.56 20 14.74 2290 675 3.48 / 216.31 5 39
5 13 947.16 20 14.84 1614 479 3.96 / 216.79 5 45
6 13 297.56 20 15.07 742 224 4.18 / 217.01 5 43
7 8 0.00 274 15.08 346 1430 5.61 / 218.44 6 130
Average= 6.42
(KJ/cycle)

Cycle 40 GMT 16/ 5/2023 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 39 15.09 467 275 0.27 / 207.50 6 10
2 7 2004.92 40 14.74 2875 1695 1.97 / 209.20 10 31
3 13 1922.12 20 14.71 2799 823 2.79 / 210.02 5 34
4 13 1508.44 20 14.73 2322 684 3.48 / 210.70 5 40
5 13 1076.16 20 14.81 1805 535 4.01 / 211.24 5 45
6 13 201.76 20 15.10 623 188 4.20 / 211.43 5 37
7 8 0.04 274 15.09 341 1410 5.61 / 212.84 6 151
Average= 6.45
(KJ/cycle)

Cycle 39 GMT 6/ 5/2023 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 39 15.10 456 269 0.27 / 201.86 6 10
2 7 2012.08 40 14.74 2893 1706 1.97 / 203.57 10 30
3 13 1923.24 20 14.72 2785 820 2.79 / 204.39 5 33
4 13 1505.16 20 14.74 2319 684 3.48 / 205.07 5 39
5 13 975.76 20 14.84 1679 498 3.98 / 205.57 5 44
6 13 326.44 20 15.06 806 243 4.22 / 205.81 5 39
7 8 0.16 274 15.10 342 1415 5.63 / 207.23 6 -99
Average= 6.48
(KJ/cycle)

Cycle 38 GMT 26/ 4/2023 19:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 39 15.09 476 280 0.28 / 196.37 6 9
2 7 2007.32 40 14.74 2876 1696 1.98 / 198.06 9 33
3 13 1921.28 20 14.72 2784 820 2.80 / 198.88 5 33
4 13 1505.08 20 14.74 2323 685 3.48 / 199.57 5 39
5 13 959.36 20 14.85 1655 492 3.97 / 200.06 5 44
6 13 102.60 20 15.15 478 145 4.12 / 200.20 6 33
7 8 0.00 272 15.11 338 1389 5.51 / 201.59 6 -99
Average= 6.50
(KJ/cycle)

Cycle 37 GMT 16/ 4/2023 22:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 39 15.09 464 273 0.27 / 190.55 6 11
2 7 2012.68 40 14.75 2889 1705 1.98 / 192.26 11 29
3 13 1916.40 20 14.73 2786 821 2.80 / 193.08 5 34
4 13 1608.92 20 14.73 2447 721 3.52 / 193.80 5 37
5 13 1163.48 20 14.79 1908 564 4.08 / 194.36 5 44
6 13 493.20 20 15.01 1034 310 4.39 / 194.67 5 43
7 8 0.00 274 15.11 341 1412 5.81 / 196.09 6 149
Average= 6.54
(KJ/cycle)

Cycle 36 GMT 7/ 4/2023 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 39 15.10 463 273 0.27 / 184.94 6 10
2 7 2007.52 41 14.75 2888 1747 2.02 / 186.68 10 32
3 13 1828.96 20 14.75 2690 794 2.81 / 187.48 5 34
4 13 1529.52 20 14.75 2335 689 3.50 / 188.17 5 39
5 13 876.80 20 14.89 1533 457 3.96 / 188.62 5 46
6 13 323.00 20 15.07 802 242 4.20 / 188.86 5 42
7 13 21.72 20 15.16 375 114 4.31 / 188.98 6 35
8 8 0.04 253 15.10 341 1303 5.62 / 190.28 6 -99
Average= 6.56
(KJ/cycle)

Cycle 35 GMT 28/ 3/2023 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 39 15.10 468 276 0.28 / 179.34 6 9
2 7 2007.64 40 14.76 2881 1701 1.98 / 181.04 9 31
3 13 1814.12 20 14.75 2676 789 2.77 / 181.83 5 35
4 13 1502.48 20 14.76 2316 684 3.45 / 182.52 5 39
5 13 955.60 20 14.87 1654 492 3.94 / 183.01 5 46
6 13 285.72 20 15.08 748 226 4.17 / 183.23 5 42
7 13 14.44 20 15.17 364 110 4.28 / 183.34 6 34
8 8 0.04 255 15.10 343 1321 5.60 / 184.66 6 -99
Average= 6.60
(KJ/cycle)

Cycle 34 GMT 18/ 3/2023 7:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 38 15.11 466 268 0.27 / 173.75 6 9
2 7 2005.92 40 14.76 2885 1703 1.97 / 175.46 23 30
3 13 1916.16 20 14.73 2799 825 2.80 / 176.28 5 35
4 13 1488.92 20 14.77 2289 676 3.47 / 176.96 5 39
5 13 951.88 20 14.88 1631 485 3.96 / 177.44 5 46
6 13 288.84 20 15.10 745 225 4.18 / 177.67 5 40
7 8 0.08 272 15.12 340 1398 5.58 / 179.07 6 151
Average= 6.63
(KJ/cycle)

Cycle 33 GMT 8/ 3/2023 10:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 39 15.11 458 270 0.27 / 168.09 6 9
2 7 2005.24 40 14.77 2875 1699 1.97 / 169.79 9 30
3 13 1915.48 20 14.75 2785 822 2.79 / 170.61 5 33
4 13 1597.32 20 14.75 2419 714 3.50 / 171.32 5 39
5 13 1039.44 20 14.86 1756 522 4.03 / 171.85 5 45
6 13 292.92 20 15.10 747 226 4.25 / 172.07 5 37
7 13 35.44 20 15.18 388 118 4.37 / 172.19 6 32
8 8 -0.08 253 15.12 339 1297 5.67 / 173.49 6 146
Average= 6.67
(KJ/cycle)

Cycle 32 GMT 26/ 2/2023 13:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 39 15.12 470 277 0.28 / 162.58 6 10
2 7 2003.52 41 14.76 2878 1742 2.02 / 164.32 10 30
3 13 1908.20 20 14.74 2791 823 2.84 / 165.15 5 34
4 13 1376.04 20 14.80 2153 637 3.48 / 165.78 5 41
5 13 957.68 20 14.87 1655 492 3.97 / 166.28 5 46
6 13 96.60 20 15.17 478 145 4.12 / 166.42 5 35
7 8 0.08 272 15.13 340 1399 5.52 / 167.82 6 -99
Average= 6.71
(KJ/cycle)

Cycle 31 GMT 16/ 2/2023 15:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 39 15.12 471 278 0.28 / 157.06 6 10
2 7 2011.80 40 14.76 2889 1706 1.98 / 158.77 10 31
3 13 1921.60 20 14.75 2776 819 2.80 / 159.59 5 34
4 13 1424.72 20 14.80 2203 652 3.45 / 160.24 5 41
5 13 894.08 20 14.90 1566 467 3.92 / 160.71 5 46
6 13 244.64 20 15.12 685 207 4.13 / 160.91 5 41
7 8 0.20 272 15.13 338 1391 5.52 / 162.30 6 168
Average= 6.76
(KJ/cycle)

Cycle 30 GMT 6/ 2/2023 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 38 15.13 466 268 0.27 / 151.49 6 9
2 7 2004.40 40 14.77 2874 1698 1.97 / 153.19 9 30
3 13 1914.68 20 14.76 2792 824 2.79 / 154.02 5 34
4 13 1496.20 20 14.78 2291 677 3.47 / 154.69 5 40
5 13 1059.16 20 14.86 1765 525 3.99 / 155.22 5 45
6 13 188.92 20 15.15 604 183 4.17 / 155.40 5 39
7 8 0.04 272 15.14 336 1384 5.56 / 156.79 6 176
Average= 6.82
(KJ/cycle)

Cycle 29 GMT 27/ 1/2023 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 38 15.13 458 263 0.26 / 146.00 6 9
2 7 2003.52 40 14.78 2862 1692 1.96 / 147.70 9 30
3 13 1915.92 20 14.76 2777 820 2.78 / 148.52 5 33
4 13 1410.36 20 14.82 2186 648 3.42 / 149.16 5 41
5 13 1089.28 20 14.85 1785 530 3.95 / 149.69 5 45
6 13 204.36 20 15.15 604 183 4.14 / 149.88 5 35
7 8 0.16 270 15.15 330 1350 5.49 / 151.23 6 138
Average= 6.87
(KJ/cycle)

Cycle 28 GMT 18/ 1/2023 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 38 15.12 472 271 0.27 / 140.47 6 11
2 7 2014.16 40 14.78 2896 1712 1.98 / 142.19 24 30
3 13 1920.76 20 14.77 2799 827 2.81 / 143.01 5 34
4 13 1490.08 20 14.80 2291 678 3.49 / 143.69 5 40
5 13 964.04 20 14.90 1659 494 3.98 / 144.19 5 46
6 13 211.60 20 15.15 632 191 4.17 / 144.38 5 37
7 8 -0.12 272 15.15 331 1364 5.54 / 145.74 6 -99
Average= 6.94
(KJ/cycle)

Cycle 27 GMT 8/ 1/2023 2:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 38 15.13 473 272 0.27 / 134.89 6 10
2 7 2005.20 40 14.78 2878 1701 1.97 / 136.59 27 32
3 13 1917.84 20 14.78 2751 813 2.79 / 137.40 5 33
4 13 1491.16 20 14.80 2292 678 3.47 / 138.08 5 39
5 13 951.24 20 14.90 1641 489 3.95 / 138.57 5 46
6 13 289.76 20 15.12 747 226 4.18 / 138.79 5 39
7 13 14.88 20 15.20 363 110 4.29 / 138.90 6 35
8 8 -0.04 253 15.14 339 1299 5.59 / 140.20 6 161
Average= 7.01
(KJ/cycle)

Cycle 26 GMT 29/12/2022 5:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 38 15.13 461 265 0.27 / 129.20 6 10
2 7 2012.92 40 14.78 2899 1714 1.98 / 130.92 10 32
3 13 1917.72 20 14.77 2755 814 2.79 / 131.73 5 35
4 13 1705.20 20 14.76 2534 748 3.54 / 132.48 5 38
5 13 1030.96 20 14.88 1734 516 4.06 / 132.99 5 47
6 13 260.40 20 15.13 694 210 4.27 / 133.20 5 43
7 8 0.16 274 15.14 340 1410 5.68 / 134.61 6 137
Average= 7.08
(KJ/cycle)

Cycle 25 GMT 19/12/2022 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 38 15.14 465 268 0.27 / 123.78 6 11
2 7 2004.80 40 14.79 2871 1698 1.97 / 125.48 11 33
3 13 1914.52 20 14.78 2765 817 2.78 / 126.30 5 35
4 13 1387.04 20 14.83 2171 644 3.43 / 126.94 5 42
5 13 872.28 20 14.93 1530 457 3.88 / 127.40 5 49
6 13 114.08 20 15.18 499 151 4.04 / 127.55 5 40
7 8 -0.04 270 15.15 339 1387 5.42 / 128.94 6 136
Average= 7.16
(KJ/cycle)

Cycle 24 GMT 9/12/2022 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 38 15.15 463 267 0.27 / 118.36 6 11
2 7 2005.72 40 14.79 2861 1693 1.96 / 120.05 11 32
3 13 1909.48 20 14.77 2776 820 2.78 / 120.87 5 35
4 13 1395.44 20 14.84 2162 642 3.42 / 121.51 5 41
5 13 870.96 20 14.94 1536 459 3.88 / 121.97 5 48
6 13 120.28 20 15.18 505 153 4.03 / 122.13 5 38
7 8 0.20 272 15.15 337 1389 5.42 / 123.51 6 -99
Average= 7.27
(KJ/cycle)

Cycle 23 GMT 29/11/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 38 15.14 464 267 0.27 / 112.94 6 12
2 7 2011.24 40 14.79 2885 1707 1.97 / 114.65 12 34
3 13 1920.44 20 14.78 2793 826 2.80 / 115.47 5 36
4 13 1403.48 20 14.84 2164 642 3.44 / 116.12 5 42
5 13 868.00 20 14.94 1529 457 3.90 / 116.57 5 47
6 13 122.04 20 15.19 512 156 4.05 / 116.73 5 38
7 8 -0.12 270 15.16 333 1363 5.42 / 118.09 6 146
Average= 7.38
(KJ/cycle)

Cycle 22 GMT 19/11/2022 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 38 15.15 471 271 0.27 / 107.44 6 12
2 7 2014.16 40 14.78 2899 1714 1.99 / 109.15 12 34
3 13 1923.68 20 14.78 2799 827 2.81 / 109.98 5 36
4 13 1392.32 20 14.83 2199 652 3.46 / 110.63 5 42
5 13 969.12 20 14.91 1667 497 3.96 / 111.13 5 47
6 13 102.52 20 15.19 488 148 4.11 / 111.28 5 37
7 8 -0.04 272 15.15 339 1397 5.51 / 112.68 6 178
Average= 7.51
(KJ/cycle)

Cycle 21 GMT 9/11/2022 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 38 15.14 461 265 0.27 / 101.89 6 13
2 7 2014.92 40 14.79 2905 1719 1.98 / 103.61 13 32
3 13 1925.16 20 14.79 2798 828 2.81 / 104.43 5 35
4 13 1393.28 20 14.84 2197 652 3.46 / 105.09 5 42
5 13 960.72 20 14.91 1654 493 3.96 / 105.58 5 47
6 13 193.12 20 15.17 613 186 4.14 / 105.76 5 39
7 8 0.00 274 15.16 338 1404 5.55 / 107.17 6 -99
Average= 7.65
(KJ/cycle)

Cycle 20 GMT 30/10/2022 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 38 15.14 470 270 0.27 / 96.29 6 12
2 7 2006.52 40 14.80 2880 1705 1.98 / 97.99 12 31
3 13 1923.16 20 14.79 2807 830 2.81 / 98.82 5 34
4 13 1400.44 20 14.84 2189 650 3.46 / 99.47 5 41
5 13 960.08 20 14.92 1656 494 3.95 / 99.97 5 46
6 13 299.08 20 15.13 770 233 4.18 / 100.20 5 43
7 8 0.12 276 15.16 340 1423 5.61 / 101.62 6 147
Average= 7.82
(KJ/cycle)

Cycle 19 GMT 21/10/2022 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 38 15.15 466 268 0.27 / 90.62 6 12
2 7 2014.16 40 14.80 2911 1723 1.99 / 92.34 12 31
3 13 1921.36 20 14.79 2801 829 2.82 / 93.17 5 35
4 13 1493.00 20 14.83 2299 682 3.50 / 93.86 5 41
5 13 950.20 20 14.92 1650 492 3.99 / 94.35 5 47
6 13 190.60 20 15.17 622 189 4.18 / 94.54 5 42
7 8 0.08 280 15.15 349 1480 5.66 / 96.02 6 142
Average= 8.00
(KJ/cycle)

Cycle 18 GMT 11/10/2022 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 38 15.14 469 270 0.27 / 85.07 6 13
2 7 2013.44 40 14.82 2892 1714 1.98 / 86.78 13 31
3 13 1924.28 20 14.81 2796 828 2.81 / 87.61 5 33
4 13 1422.72 20 14.85 2223 660 3.47 / 88.27 5 40
5 13 904.84 20 14.95 1577 472 3.94 / 88.74 5 46
6 13 262.00 20 15.16 702 213 4.16 / 88.95 5 40
7 8 0.00 274 15.17 337 1401 5.56 / 90.35 6 197
Average= 8.21
(KJ/cycle)

Cycle 17 GMT 1/10/2022 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 38 15.15 474 273 0.27 / 79.43 6 14
2 7 2014.48 41 14.81 2912 1768 2.04 / 81.20 14 32
3 13 1924.40 20 14.81 2788 826 2.87 / 82.02 5 35
4 13 1496.20 20 14.84 2295 681 3.55 / 82.71 5 42
5 13 850.76 20 14.97 1504 450 4.00 / 83.16 5 47
6 13 319.76 20 15.15 780 236 4.23 / 83.39 5 42
7 8 0.08 272 15.17 340 1403 5.64 / 84.80 6 212
Average= 8.48
(KJ/cycle)

Cycle 16 GMT 21/ 9/2022 9:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 38 15.15 479 276 0.28 / 73.83 6 15
2 7 2006.48 40 14.84 2873 1705 1.98 / 75.53 15 32
3 13 1922.32 20 14.82 2782 825 2.81 / 76.36 5 35
4 13 1498.12 20 14.84 2297 682 3.49 / 77.04 5 41
5 13 858.00 20 14.97 1524 456 3.94 / 77.50 5 46
6 13 319.44 20 15.15 788 239 4.18 / 77.74 5 40
7 8 -0.04 274 15.17 342 1422 5.60 / 79.16 6 142
Average= 8.80
(KJ/cycle)

Cycle 15 GMT 11/ 9/2022 12: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 36 15.17 457 250 0.25 / 68.09 6 13
2 3 1072.32 2 15.17 1773 54 0.30 / 68.14 5 32
3 7 2009.24 40 14.82 2906 1723 2.03 / 69.86 32 32
4 13 1930.52 20 14.81 2804 831 2.86 / 70.69 5 35
5 13 1508.92 20 14.84 2317 688 3.54 / 71.38 5 42
6 13 1133.64 20 14.89 1856 553 4.10 / 71.93 5 47
7 13 232.32 20 15.18 660 200 4.30 / 72.13 5 43
8 8 0.28 276 15.18 339 1420 5.72 / 73.55 6 191
Average= 9.19
(KJ/cycle)

Cycle 14 GMT 1/ 9/2022 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 37 15.14 474 266 0.27 / 62.50 6 15
2 7 2014.16 40 14.85 2878 1710 1.98 / 64.21 15 30
3 13 1928.56 20 14.83 2799 830 2.81 / 65.04 5 35
4 13 1620.52 20 14.83 2429 720 3.53 / 65.76 5 39
5 13 975.48 20 14.95 1658 496 4.02 / 66.26 5 46
6 13 222.12 20 15.19 643 195 4.22 / 66.46 5 35
7 8 -0.12 272 15.19 334 1380 5.60 / 67.84 6 159
Average= 9.69
(KJ/cycle)

Cycle 13 GMT 22/ 8/2022 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 38 15.15 471 271 0.27 / 56.94 6 12
2 3 935.08 -1 15.51 6 0 0.00 / 56.94 6 12
3 7 2004.52 40 14.83 2859 1696 1.97 / 58.63 12 33
4 13 1905.56 20 14.83 2777 824 2.79 / 59.46 5 35
5 13 1468.60 20 14.85 2272 675 3.47 / 60.13 5 42
6 13 809.12 20 14.99 1459 437 3.90 / 60.57 5 50
7 13 150.68 20 15.19 562 171 4.07 / 60.74 5 46
8 8 0.04 282 15.16 351 1501 5.57 / 62.24 5 130
Average= 10.37
(KJ/cycle)

Cycle 12 GMT 12/ 8/2022 20:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 38 15.18 477 275 0.28 / 51.18 6 14
2 7 2006.60 41 14.83 2867 1743 2.02 / 52.92 14 34
3 13 1923.24 20 14.82 2775 823 2.84 / 53.74 5 38
4 13 1383.32 20 14.87 2143 637 3.48 / 54.38 5 44
5 13 868.00 20 14.97 1534 459 3.94 / 54.84 5 48
6 13 551.96 20 15.04 1132 341 4.28 / 55.18 5 50
7 8 0.04 280 15.16 350 1486 5.76 / 56.66 6 -99
Average= 11.33
(KJ/cycle)

Cycle 11 GMT 2/ 8/2022 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 38 15.21 454 262 0.26 / 45.62 6 11
2 7 2015.12 40 14.85 2880 1711 1.97 / 47.33 11 30
3 13 1937.12 20 14.84 2798 830 2.80 / 48.17 5 33
4 13 1413.72 20 14.88 2196 654 3.46 / 48.82 5 41
5 13 1087.96 20 14.92 1802 538 3.99 / 49.36 5 44
6 13 285.32 20 15.19 725 220 4.22 / 49.58 5 35
7 13 31.72 20 15.26 372 114 4.33 / 49.69 6 32
8 8 -0.08 248 15.21 321 1211 5.54 / 50.90 6 -99
Average= 12.73
(KJ/cycle)

Cycle 10 GMT 24/ 7/2022 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 38 15.20 459 265 0.27 / 40.12 6 12
2 7 2003.04 40 14.87 2881 1714 1.98 / 41.83 18 30
3 13 1916.68 20 14.86 2779 826 2.80 / 42.66 5 31
4 13 1600.24 20 14.86 2408 716 3.52 / 43.38 5 37
5 13 944.64 20 15.00 1601 480 4.00 / 43.86 5 40
6 13 299.76 20 15.21 731 222 4.22 / 44.08 5 31
7 8 0.24 265 15.23 318 1283 5.51 / 45.36 6 138
Average= 15.12
(KJ/cycle)

Cycle 9 GMT 14/ 7/2022 4:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 36 15.21 454 249 0.25 / 34.51 6 12
2 10 1005.48 3 15.25 1628 74 0.32 / 34.59 6 18
3 7 2005.20 40 14.88 2845 1693 2.02 / 36.28 18 29
4 13 1921.80 20 14.86 2765 822 2.84 / 37.10 5 32
5 13 1594.04 20 14.86 2413 717 3.56 / 37.82 5 37
6 13 1033.44 20 14.96 1737 520 4.08 / 38.34 5 42
7 13 262.60 20 15.22 680 207 4.28 / 38.54 6 31
8 13 62.16 20 15.27 405 124 4.41 / 38.67 6 31
9 8 0.04 246 15.22 317 1187 5.59 / 39.86 6 143
Average= 19.93
(KJ/cycle)

Cycle 8 GMT 4/ 7/2022 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 36 15.19 453 248 0.25 / 29.17 6 11
2 7 2003.88 40 14.88 2863 1704 1.95 / 30.88 11 30
3 13 1911.32 20 14.86 2758 820 2.77 / 31.70 5 33
4 13 1498.96 20 14.89 2287 681 3.45 / 32.38 5 38
5 13 960.24 20 15.00 1611 483 3.94 / 32.86 5 40
6 13 94.40 20 15.27 434 133 4.07 / 33.00 6 27
7 8 -0.04 265 15.23 314 1267 5.34 / 34.26 6 -99
Average= 34.26
(KJ/cycle)

Cycle 6 GMT 14/ 6/2022 13:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 35 15.20 455 242 0.24 / 23.88 6 10
2 7 2005.32 40 14.87 2870 1707 1.95 / 25.58 10 30
3 13 1915.64 20 14.87 2768 823 2.77 / 26.41 5 34
4 13 1281.56 20 14.92 2036 608 3.38 / 27.01 5 42
5 13 874.04 20 15.00 1524 457 3.84 / 27.47 5 46
6 13 113.36 20 15.25 473 144 3.98 / 27.62 6 31
7 8 -0.08 270 15.22 319 1311 5.29 / 28.93 6 165
Average= 4.13
(KJ/cycle)

Cycle 5 GMT 4/ 6/2022 15:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 31 15.22 446 210 0.21 / 19.03 6 10
2 10 1016.88 3 15.21 1663 76 0.29 / 19.11 5 21
3 3 1065.76 2 15.23 1752 53 0.34 / 19.16 5 31
4 7 1543.88 40 15.01 2338 1404 1.74 / 20.57 31 39
5 13 1470.96 20 15.00 2260 678 2.42 / 21.24 5 39
6 13 1268.28 20 14.99 2014 604 3.03 / 21.85 5 43
7 13 625.08 20 15.12 1202 363 3.39 / 22.21 5 47
8 13 42.28 20 15.29 380 116 3.50 / 22.33 5 37
9 8 0.04 265 15.23 324 1308 4.81 / 23.63 6 157
Average= 3.94
(KJ/cycle)

Cycle 4 GMT 25/ 5/2022 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 35 15.21 435 232 0.23 / 14.31 6 11
2 7 1516.76 40 15.04 2283 1373 1.61 / 15.68 11 31
3 13 1449.60 20 15.02 2219 667 2.27 / 16.35 5 34
4 13 1253.72 20 15.01 1983 595 2.87 / 16.94 5 38
5 13 923.04 20 15.04 1583 476 3.34 / 17.42 5 42
6 13 95.36 20 15.28 448 137 3.48 / 17.56 6 30
7 8 0.20 263 15.24 316 1267 4.75 / 18.82 6 137
Average= 3.76
(KJ/cycle)

Cycle 3 GMT 24/ 5/2022 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 35 15.20 447 238 0.24 / 9.72 6 10
2 3 1034.36 1 15.24 1722 26 0.26 / 9.75 5 27
3 7 1518.04 40 15.04 2282 1373 1.64 / 11.12 27 29
4 13 1453.68 20 15.01 2231 670 2.31 / 11.79 5 31
5 13 1161.36 20 15.01 1878 564 2.87 / 12.35 5 37
6 13 632.76 20 15.13 1192 361 3.23 / 12.71 5 38
7 13 43.84 20 15.29 380 116 3.35 / 12.83 6 29
8 8 0.04 261 15.24 313 1245 4.59 / 14.08 6 -99
Average= 3.52
(KJ/cycle)

Cycle 2 GMT 22/ 5/2022 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 31 15.24 448 212 0.21 / 4.94 6 10
2 10 1030.48 3 15.22 1694 77 0.29 / 5.02 5 21
3 3 1069.16 2 15.22 1769 54 0.34 / 5.07 5 29
4 7 1509.36 41 15.03 2280 1405 1.75 / 6.48 29 30
5 13 1446.80 20 15.01 2216 665 2.41 / 7.14 5 33
6 13 1151.48 20 15.01 1868 561 2.97 / 7.70 5 37
7 13 721.44 20 15.09 1316 397 3.37 / 8.10 5 39
8 13 71.08 20 15.27 417 127 3.50 / 8.23 6 29
9 8 -0.08 263 15.23 314 1258 4.76 / 9.48 6 183
Average= 3.16
(KJ/cycle)

Cycle 1 GMT 21/ 5/2022 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 31 15.40 427 204 0.20 / 1.98 6 7
2 10 1036.40 3 15.25 1704 78 0.28 / 2.06 5 18
3 3 1055.64 1 15.25 1754 27 0.31 / 2.09 5 25
4 7 1020.16 40 15.14 1684 1020 1.33 / 3.11 25 33
5 13 484.92 20 15.24 992 302 1.63 / 3.41 5 34
6 8 -0.04 276 15.28 313 1320 2.95 / 4.73 6 156
Average= 2.36
(KJ/cycle)

Cycle 0 GMT 20/ 5/2022 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 132.16 30 15.57 431 201 0.20 / 0.20 6 9
2 7 143.12 40 15.55 443 276 0.48 / 0.48 9 9
3 13 90.48 20 15.53 378 117 0.59 / 0.59 6 12
4 8 0.16 285 15.48 268 1182 1.78 / 1.78 6 -99
Average= 1.78
(KJ/cycle)