SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 38 | 14.99 | 416 | 237 | 0.24 / 604.22 | 6 | 10 |
2 | 7 | 2005.16 | 40 | 14.63 | 3086 | 1806 | 2.04 / 606.02 | 10 | 50 |
3 | 13 | 1921.60 | 20 | 14.61 | 2973 | 869 | 2.91 / 606.89 | 6 | 52 |
4 | 13 | 1509.44 | 20 | 14.62 | 2418 | 707 | 3.62 / 607.60 | 6 | 61 |
5 | 13 | 963.96 | 20 | 14.72 | 1681 | 495 | 4.11 / 608.09 | 6 | 69 |
6 | 13 | 306.80 | 20 | 14.92 | 769 | 229 | 4.34 / 608.32 | 6 | 76 |
7 | 13 | 37.80 | 20 | 15.01 | 370 | 111 | 4.45 / 608.43 | 6 | 68 |
8 | 8 | -0.12 | 242 | 14.97 | 307 | 1112 | 5.57 / 609.54 | 6 | 148 |
Average= | 6.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 38 | 14.97 | 423 | 241 | 0.24 / 598.67 | 6 | 13 |
2 | 7 | 2003.44 | 40 | 14.63 | 3086 | 1806 | 2.05 / 600.47 | 13 | 49 |
3 | 13 | 1914.28 | 20 | 14.61 | 2976 | 870 | 2.92 / 601.34 | 6 | 51 |
4 | 13 | 1599.24 | 20 | 14.60 | 2534 | 740 | 3.66 / 602.08 | 6 | 58 |
5 | 13 | 937.48 | 20 | 14.74 | 1644 | 485 | 4.14 / 602.57 | 6 | 71 |
6 | 13 | 296.56 | 20 | 14.93 | 756 | 226 | 4.37 / 602.79 | 6 | 73 |
7 | 13 | 37.48 | 20 | 15.02 | 360 | 108 | 4.47 / 602.90 | 6 | 66 |
8 | 8 | -0.04 | 240 | 14.97 | 300 | 1078 | 5.55 / 603.98 | 6 | 129 |
Average= | 6.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 38 | 14.98 | 450 | 256 | 0.26 / 593.18 | 6 | 14 |
2 | 7 | 2004.60 | 40 | 14.63 | 3078 | 1801 | 2.06 / 594.98 | 14 | 49 |
3 | 13 | 1915.84 | 20 | 14.61 | 2977 | 870 | 2.93 / 595.85 | 6 | 53 |
4 | 13 | 1401.76 | 20 | 14.65 | 2284 | 669 | 3.60 / 596.52 | 6 | 61 |
5 | 13 | 966.92 | 20 | 14.72 | 1694 | 499 | 4.10 / 597.02 | 6 | 68 |
6 | 13 | 210.08 | 20 | 14.96 | 641 | 192 | 4.29 / 597.21 | 6 | 70 |
7 | 13 | 48.00 | 20 | 15.01 | 393 | 118 | 4.40 / 597.33 | 6 | 67 |
8 | 8 | 0.00 | 240 | 14.97 | 305 | 1096 | 5.50 / 598.43 | 6 | 133 |
Average= | 6.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 38 | 14.98 | 448 | 255 | 0.26 / 587.53 | 6 | 15 |
2 | 7 | 2015.16 | 40 | 14.62 | 3109 | 1818 | 2.07 / 589.35 | 15 | 46 |
3 | 13 | 1925.32 | 20 | 14.60 | 2986 | 872 | 2.95 / 590.22 | 6 | 53 |
4 | 13 | 1605.20 | 20 | 14.59 | 2554 | 745 | 3.69 / 590.97 | 6 | 58 |
5 | 13 | 951.12 | 20 | 14.73 | 1669 | 492 | 4.18 / 591.46 | 6 | 69 |
6 | 13 | 305.80 | 20 | 14.93 | 776 | 232 | 4.41 / 591.69 | 6 | 73 |
7 | 13 | 40.68 | 20 | 15.02 | 376 | 113 | 4.53 / 591.80 | 6 | 65 |
8 | 8 | 0.00 | 242 | 14.97 | 310 | 1123 | 5.65 / 592.93 | 6 | 132 |
Average= | 6.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 38 | 14.98 | 432 | 246 | 0.25 / 581.88 | 6 | 15 |
2 | 7 | 2013.44 | 40 | 14.63 | 3087 | 1807 | 2.05 / 583.69 | 15 | 52 |
3 | 13 | 1924.88 | 20 | 14.61 | 2983 | 872 | 2.92 / 584.56 | 6 | 52 |
4 | 13 | 1512.64 | 20 | 14.62 | 2419 | 707 | 3.63 / 585.27 | 6 | 62 |
5 | 13 | 1072.40 | 20 | 14.70 | 1821 | 535 | 4.17 / 585.80 | 6 | 69 |
6 | 13 | 395.92 | 20 | 14.89 | 895 | 267 | 4.43 / 586.07 | 6 | 77 |
7 | 13 | 34.08 | 20 | 15.02 | 363 | 109 | 4.54 / 586.18 | 6 | 65 |
8 | 8 | 0.04 | 242 | 14.97 | 303 | 1098 | 5.64 / 587.28 | 6 | 135 |
Average= | 6.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 38 | 14.98 | 456 | 260 | 0.26 / 576.37 | 6 | 17 |
2 | 7 | 2004.56 | 40 | 14.64 | 3078 | 1802 | 2.06 / 578.17 | 17 | 50 |
3 | 13 | 1915.56 | 20 | 14.61 | 2969 | 868 | 2.93 / 579.04 | 6 | 53 |
4 | 13 | 1502.64 | 20 | 14.62 | 2404 | 703 | 3.63 / 579.74 | 6 | 63 |
5 | 13 | 952.52 | 20 | 14.73 | 1663 | 490 | 4.12 / 580.23 | 6 | 70 |
6 | 13 | 208.04 | 20 | 14.97 | 615 | 184 | 4.31 / 580.42 | 6 | 71 |
7 | 13 | 42.80 | 20 | 15.02 | 367 | 110 | 4.42 / 580.53 | 6 | 68 |
8 | 8 | -0.04 | 240 | 14.97 | 309 | 1110 | 5.53 / 581.64 | 6 | 138 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 38 | 14.98 | 433 | 246 | 0.25 / 570.77 | 6 | 15 |
2 | 7 | 2003.92 | 40 | 14.64 | 3090 | 1810 | 2.06 / 572.58 | 15 | 51 |
3 | 13 | 1917.48 | 20 | 14.62 | 2972 | 869 | 2.92 / 573.45 | 6 | 50 |
4 | 13 | 1499.56 | 20 | 14.63 | 2395 | 701 | 3.63 / 574.15 | 6 | 61 |
5 | 13 | 965.16 | 20 | 14.73 | 1682 | 496 | 4.12 / 574.65 | 6 | 71 |
6 | 13 | 310.12 | 20 | 14.93 | 781 | 233 | 4.35 / 574.88 | 6 | 75 |
7 | 13 | 37.40 | 20 | 15.01 | 375 | 113 | 4.47 / 574.99 | 6 | 64 |
8 | 8 | 0.04 | 242 | 14.97 | 308 | 1116 | 5.58 / 576.11 | 6 | 136 |
Average= | 6.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 38 | 14.97 | 453 | 258 | 0.26 / 565.14 | 6 | 17 |
2 | 7 | 2005.16 | 41 | 14.63 | 3085 | 1850 | 2.11 / 566.99 | 17 | 48 |
3 | 13 | 1921.64 | 20 | 14.61 | 2982 | 871 | 2.98 / 567.86 | 6 | 53 |
4 | 13 | 1617.28 | 20 | 14.60 | 2556 | 746 | 3.73 / 568.61 | 6 | 60 |
5 | 13 | 967.40 | 20 | 14.73 | 1675 | 493 | 4.22 / 569.10 | 6 | 72 |
6 | 13 | 223.88 | 20 | 14.96 | 643 | 192 | 4.41 / 569.29 | 6 | 69 |
7 | 13 | 53.20 | 20 | 15.01 | 388 | 116 | 4.53 / 569.41 | 6 | 63 |
8 | 8 | -0.04 | 242 | 14.97 | 308 | 1116 | 5.64 / 570.53 | 6 | 136 |
Average= | 6.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 38 | 14.98 | 437 | 249 | 0.25 / 559.43 | 6 | 18 |
2 | 7 | 2006.12 | 40 | 14.64 | 3076 | 1801 | 2.05 / 561.23 | 18 | 50 |
3 | 13 | 1919.76 | 20 | 14.62 | 2948 | 862 | 2.91 / 562.09 | 6 | 54 |
4 | 13 | 1616.32 | 20 | 14.60 | 2565 | 749 | 3.66 / 562.84 | 6 | 59 |
5 | 13 | 1055.88 | 20 | 14.71 | 1811 | 533 | 4.19 / 563.38 | 6 | 67 |
6 | 13 | 381.84 | 20 | 14.90 | 889 | 265 | 4.46 / 563.64 | 6 | 78 |
7 | 13 | 31.68 | 20 | 15.02 | 368 | 111 | 4.57 / 563.75 | 6 | 68 |
8 | 8 | 0.08 | 242 | 14.97 | 312 | 1130 | 5.70 / 564.88 | 6 | 135 |
Average= | 6.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 38 | 14.96 | 446 | 254 | 0.25 / 553.89 | 6 | 18 |
2 | 7 | 2003.60 | 40 | 14.64 | 3079 | 1803 | 2.06 / 555.70 | 18 | 45 |
3 | 13 | 1919.28 | 20 | 14.62 | 2960 | 866 | 2.92 / 556.56 | 6 | 50 |
4 | 13 | 1403.96 | 20 | 14.66 | 2277 | 668 | 3.59 / 557.23 | 6 | 60 |
5 | 13 | 977.16 | 20 | 14.73 | 1685 | 496 | 4.09 / 557.73 | 6 | 69 |
6 | 13 | 328.04 | 20 | 14.93 | 796 | 238 | 4.32 / 557.96 | 6 | 73 |
7 | 13 | 23.56 | 20 | 15.03 | 338 | 102 | 4.43 / 558.07 | 6 | 60 |
8 | 8 | -0.04 | 242 | 14.97 | 308 | 1116 | 5.54 / 559.18 | 6 | 145 |
Average= | 6.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 38 | 14.98 | 426 | 242 | 0.24 / 548.27 | 6 | 15 |
2 | 7 | 2003.56 | 41 | 14.64 | 3077 | 1847 | 2.09 / 550.12 | 15 | 48 |
3 | 13 | 1921.80 | 20 | 14.61 | 2978 | 870 | 2.96 / 550.99 | 6 | 51 |
4 | 13 | 1405.40 | 20 | 14.65 | 2272 | 666 | 3.63 / 551.65 | 6 | 60 |
5 | 13 | 888.00 | 20 | 14.76 | 1569 | 463 | 4.09 / 552.12 | 6 | 70 |
6 | 13 | 445.76 | 20 | 14.88 | 965 | 287 | 4.38 / 552.40 | 6 | 77 |
7 | 13 | 20.88 | 20 | 15.02 | 352 | 106 | 4.48 / 552.51 | 6 | 65 |
8 | 8 | -0.04 | 240 | 14.97 | 315 | 1132 | 5.61 / 553.64 | 6 | 137 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 38 | 14.97 | 443 | 252 | 0.25 / 542.69 | 6 | 21 |
2 | 7 | 2007.24 | 40 | 14.64 | 3098 | 1814 | 2.07 / 544.50 | 21 | 51 |
3 | 13 | 1923.28 | 20 | 14.62 | 2984 | 873 | 2.94 / 545.38 | 6 | 54 |
4 | 13 | 1503.60 | 20 | 14.63 | 2421 | 708 | 3.65 / 546.08 | 6 | 61 |
5 | 13 | 958.96 | 20 | 14.74 | 1679 | 495 | 4.14 / 546.58 | 6 | 70 |
6 | 13 | 298.68 | 20 | 14.94 | 769 | 230 | 4.37 / 546.81 | 6 | 73 |
7 | 13 | 19.48 | 20 | 15.03 | 350 | 105 | 4.48 / 546.91 | 6 | 65 |
8 | 8 | 0.00 | 240 | 14.98 | 310 | 1115 | 5.59 / 548.03 | 6 | 132 |
Average= | 6.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 38 | 14.98 | 443 | 252 | 0.25 / 537.08 | 6 | 16 |
2 | 7 | 2008.84 | 40 | 14.64 | 3095 | 1812 | 2.06 / 538.89 | 16 | 51 |
3 | 13 | 1928.20 | 20 | 14.62 | 2981 | 872 | 2.94 / 539.76 | 6 | 54 |
4 | 13 | 1517.36 | 20 | 14.63 | 2437 | 713 | 3.65 / 540.47 | 6 | 62 |
5 | 13 | 971.68 | 20 | 14.74 | 1700 | 501 | 4.15 / 540.97 | 6 | 69 |
6 | 13 | 320.32 | 20 | 14.93 | 798 | 238 | 4.39 / 541.21 | 6 | 73 |
7 | 13 | 19.24 | 20 | 15.02 | 352 | 106 | 4.49 / 541.32 | 6 | 68 |
8 | 8 | 0.00 | 240 | 14.97 | 311 | 1117 | 5.61 / 542.44 | 6 | 137 |
Average= | 6.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 38 | 14.97 | 449 | 255 | 0.26 / 531.47 | 6 | 19 |
2 | 7 | 2014.24 | 40 | 14.64 | 3098 | 1814 | 2.07 / 533.29 | 19 | 48 |
3 | 13 | 1925.28 | 20 | 14.62 | 2983 | 872 | 2.94 / 534.16 | 6 | 53 |
4 | 13 | 1608.56 | 20 | 14.61 | 2545 | 744 | 3.69 / 534.90 | 6 | 60 |
5 | 13 | 1053.00 | 20 | 14.71 | 1796 | 528 | 4.21 / 535.43 | 6 | 70 |
6 | 13 | 193.36 | 20 | 14.98 | 600 | 180 | 4.39 / 535.61 | 6 | 72 |
7 | 13 | 19.88 | 20 | 15.03 | 336 | 101 | 4.49 / 535.71 | 6 | 70 |
8 | 8 | 0.04 | 240 | 14.98 | 309 | 1111 | 5.61 / 536.82 | 6 | 131 |
Average= | 6.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 38 | 14.96 | 450 | 256 | 0.26 / 525.92 | 6 | 16 |
2 | 7 | 2004.84 | 40 | 14.65 | 3083 | 1807 | 2.06 / 527.73 | 16 | 50 |
3 | 13 | 1920.68 | 20 | 14.62 | 2971 | 869 | 2.93 / 528.59 | 6 | 53 |
4 | 13 | 1496.20 | 20 | 14.64 | 2402 | 703 | 3.63 / 529.30 | 6 | 61 |
5 | 13 | 1047.28 | 20 | 14.72 | 1796 | 529 | 4.16 / 529.83 | 6 | 69 |
6 | 13 | 187.24 | 20 | 14.98 | 601 | 180 | 4.34 / 530.01 | 6 | 71 |
7 | 13 | 16.40 | 20 | 15.03 | 340 | 102 | 4.45 / 530.11 | 6 | 70 |
8 | 8 | -0.04 | 240 | 14.97 | 309 | 1110 | 5.56 / 531.22 | 6 | 141 |
Average= | 6.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 37 | 14.97 | 439 | 243 | 0.24 / 520.24 | 6 | 21 |
2 | 10 | 1003.16 | 3 | 14.98 | 1738 | 78 | 0.32 / 520.32 | 6 | 53 |
3 | 3 | 935.24 | -1 | 15.37 | 15 | 0 | 0.08 / 520.32 | 6 | 53 |
4 | 7 | 2006.28 | 40 | 14.65 | 3087 | 1809 | 2.13 / 522.13 | 53 | 52 |
5 | 13 | 1920.80 | 20 | 14.63 | 2960 | 866 | 3.00 / 522.99 | 6 | 52 |
6 | 13 | 1493.32 | 20 | 14.64 | 2404 | 704 | 3.70 / 523.70 | 6 | 61 |
7 | 13 | 948.60 | 20 | 14.75 | 1666 | 491 | 4.19 / 524.19 | 6 | 69 |
8 | 13 | 298.76 | 20 | 14.93 | 777 | 232 | 4.42 / 524.42 | 6 | 75 |
9 | 13 | 15.52 | 20 | 15.03 | 345 | 104 | 4.53 / 524.52 | 6 | 70 |
10 | 8 | -0.16 | 238 | 14.97 | 320 | 1140 | 5.67 / 525.66 | 6 | 136 |
Average= | 7.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 37 | 14.98 | 439 | 243 | 0.24 / 514.75 | 6 | 15 |
2 | 7 | 2004.32 | 40 | 14.64 | 3089 | 1809 | 2.05 / 516.56 | 15 | 50 |
3 | 13 | 1913.92 | 20 | 14.62 | 2968 | 868 | 2.92 / 517.43 | 6 | 52 |
4 | 13 | 1494.84 | 20 | 14.64 | 2394 | 701 | 3.62 / 518.13 | 6 | 61 |
5 | 13 | 856.60 | 20 | 14.77 | 1542 | 456 | 4.08 / 518.58 | 6 | 69 |
6 | 13 | 217.64 | 20 | 14.96 | 652 | 195 | 4.27 / 518.78 | 6 | 74 |
7 | 8 | 0.04 | 261 | 14.98 | 311 | 1216 | 5.49 / 520.00 | 6 | 145 |
Average= | 7.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 37 | 14.98 | 452 | 251 | 0.25 / 509.20 | 6 | 17 |
2 | 7 | 2005.52 | 40 | 14.65 | 3077 | 1803 | 2.05 / 511.00 | 17 | 49 |
3 | 13 | 1922.04 | 20 | 14.62 | 2970 | 868 | 2.92 / 511.87 | 6 | 52 |
4 | 13 | 1509.92 | 20 | 14.64 | 2433 | 712 | 3.63 / 512.58 | 6 | 60 |
5 | 13 | 880.72 | 20 | 14.77 | 1568 | 463 | 4.10 / 513.05 | 6 | 70 |
6 | 13 | 333.56 | 20 | 14.92 | 824 | 246 | 4.34 / 513.29 | 6 | 75 |
7 | 13 | 12.04 | 20 | 15.03 | 339 | 102 | 4.45 / 513.39 | 6 | 67 |
8 | 8 | -0.16 | 240 | 14.97 | 310 | 1114 | 5.56 / 514.51 | 6 | 134 |
Average= | 7.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 37 | 14.98 | 441 | 244 | 0.24 / 503.67 | 6 | 13 |
2 | 7 | 2007.60 | 41 | 14.64 | 3093 | 1857 | 2.10 / 505.53 | 13 | 52 |
3 | 13 | 1925.80 | 20 | 14.62 | 2980 | 871 | 2.97 / 506.40 | 6 | 53 |
4 | 13 | 1502.80 | 20 | 14.64 | 2399 | 702 | 3.67 / 507.10 | 6 | 60 |
5 | 13 | 958.88 | 20 | 14.74 | 1668 | 492 | 4.17 / 507.59 | 6 | 70 |
6 | 13 | 109.36 | 20 | 15.01 | 464 | 139 | 4.31 / 507.73 | 6 | 70 |
7 | 13 | 21.60 | 20 | 15.03 | 346 | 104 | 4.41 / 507.83 | 6 | 61 |
8 | 8 | 0.04 | 240 | 14.98 | 310 | 1115 | 5.52 / 508.95 | 6 | 136 |
Average= | 7.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 37 | 14.99 | 440 | 244 | 0.24 / 498.13 | 6 | 12 |
2 | 7 | 2006.52 | 40 | 14.64 | 3090 | 1810 | 2.05 / 499.94 | 12 | 52 |
3 | 13 | 1925.08 | 20 | 14.63 | 2973 | 870 | 2.92 / 500.81 | 6 | 56 |
4 | 13 | 1511.00 | 20 | 14.64 | 2409 | 705 | 3.63 / 501.52 | 6 | 61 |
5 | 13 | 965.36 | 20 | 14.74 | 1675 | 494 | 4.12 / 502.01 | 6 | 70 |
6 | 13 | 219.88 | 20 | 14.97 | 637 | 191 | 4.31 / 502.20 | 6 | 72 |
7 | 13 | 22.52 | 20 | 15.03 | 345 | 104 | 4.42 / 502.30 | 6 | 64 |
8 | 8 | 0.00 | 240 | 14.97 | 312 | 1121 | 5.54 / 503.42 | 6 | 140 |
Average= | 7.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 37 | 14.99 | 429 | 238 | 0.24 / 492.62 | 6 | 14 |
2 | 7 | 2003.16 | 40 | 14.64 | 3087 | 1808 | 2.05 / 494.43 | 14 | 48 |
3 | 13 | 1916.76 | 20 | 14.62 | 2978 | 871 | 2.92 / 495.30 | 6 | 54 |
4 | 13 | 1513.56 | 20 | 14.63 | 2433 | 712 | 3.63 / 496.01 | 6 | 61 |
5 | 13 | 879.40 | 20 | 14.77 | 1559 | 461 | 4.09 / 496.47 | 6 | 70 |
6 | 13 | 243.68 | 20 | 14.96 | 676 | 202 | 4.29 / 496.68 | 6 | 73 |
7 | 13 | 27.40 | 20 | 15.02 | 356 | 107 | 4.40 / 496.78 | 6 | 71 |
8 | 8 | -0.04 | 240 | 14.98 | 307 | 1104 | 5.50 / 497.89 | 6 | 133 |
Average= | 7.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 37 | 14.98 | 440 | 244 | 0.24 / 487.14 | 6 | 11 |
2 | 7 | 2005.16 | 40 | 14.64 | 3085 | 1807 | 2.05 / 488.94 | 11 | 48 |
3 | 13 | 1919.68 | 20 | 14.62 | 2973 | 869 | 2.92 / 489.81 | 6 | 53 |
4 | 13 | 1506.88 | 20 | 14.63 | 2418 | 708 | 3.63 / 490.52 | 6 | 61 |
5 | 13 | 861.24 | 20 | 14.77 | 1538 | 454 | 4.08 / 490.97 | 6 | 70 |
6 | 13 | 221.20 | 20 | 14.97 | 644 | 193 | 4.27 / 491.17 | 6 | 72 |
7 | 13 | 26.20 | 20 | 15.03 | 356 | 107 | 4.38 / 491.27 | 6 | 64 |
8 | 8 | 0.00 | 242 | 14.97 | 307 | 1112 | 5.49 / 492.38 | 6 | 153 |
Average= | 7.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 37 | 14.98 | 440 | 244 | 0.24 / 481.57 | 6 | 13 |
2 | 7 | 2006.40 | 40 | 14.64 | 3093 | 1811 | 2.06 / 483.38 | 13 | 48 |
3 | 13 | 1924.64 | 20 | 14.63 | 2979 | 872 | 2.93 / 484.25 | 6 | 52 |
4 | 13 | 1415.80 | 20 | 14.65 | 2314 | 678 | 3.60 / 484.93 | 6 | 61 |
5 | 13 | 899.08 | 20 | 14.76 | 1585 | 468 | 4.07 / 485.40 | 6 | 69 |
6 | 13 | 359.72 | 20 | 14.91 | 855 | 255 | 4.33 / 485.65 | 6 | 76 |
7 | 13 | 26.88 | 20 | 15.02 | 360 | 108 | 4.44 / 485.76 | 6 | 64 |
8 | 13 | 10.56 | 20 | 15.02 | 336 | 101 | 4.54 / 485.86 | 6 | 67 |
9 | 8 | -0.08 | 223 | 14.97 | 309 | 1032 | 5.57 / 486.89 | 6 | 131 |
Average= | 7.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 37 | 14.98 | 446 | 247 | 0.25 / 476.08 | 6 | 10 |
2 | 7 | 2004.96 | 40 | 14.64 | 3084 | 1806 | 2.05 / 477.89 | 10 | 51 |
3 | 13 | 1916.92 | 20 | 14.62 | 2981 | 872 | 2.92 / 478.76 | 6 | 53 |
4 | 13 | 1400.24 | 20 | 14.66 | 2265 | 664 | 3.59 / 479.42 | 6 | 62 |
5 | 13 | 968.28 | 20 | 14.73 | 1675 | 493 | 4.08 / 479.92 | 6 | 69 |
6 | 13 | 199.16 | 20 | 14.97 | 610 | 183 | 4.27 / 480.10 | 6 | 73 |
7 | 13 | 23.68 | 20 | 15.02 | 343 | 103 | 4.37 / 480.20 | 6 | 64 |
8 | 8 | 0.08 | 242 | 14.98 | 309 | 1120 | 5.49 / 481.32 | 6 | 136 |
Average= | 7.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 37 | 14.98 | 431 | 239 | 0.24 / 470.47 | 6 | 11 |
2 | 7 | 2006.28 | 40 | 14.65 | 3077 | 1803 | 2.04 / 472.27 | 11 | 48 |
3 | 13 | 1926.00 | 20 | 14.62 | 2973 | 869 | 2.91 / 473.14 | 6 | 51 |
4 | 13 | 1500.88 | 20 | 14.64 | 2417 | 708 | 3.62 / 473.85 | 6 | 62 |
5 | 13 | 960.68 | 20 | 14.74 | 1687 | 497 | 4.12 / 474.35 | 6 | 69 |
6 | 13 | 313.12 | 20 | 14.93 | 792 | 236 | 4.35 / 474.58 | 6 | 77 |
7 | 13 | 40.96 | 20 | 15.01 | 382 | 115 | 4.47 / 474.70 | 6 | 68 |
8 | 13 | 12.88 | 20 | 15.02 | 339 | 102 | 4.57 / 474.80 | 6 | 66 |
9 | 8 | -0.08 | 220 | 14.96 | 314 | 1033 | 5.60 / 475.83 | 6 | 131 |
Average= | 7.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 37 | 14.97 | 438 | 243 | 0.24 / 464.83 | 6 | 11 |
2 | 7 | 2006.28 | 40 | 14.65 | 3088 | 1810 | 2.05 / 466.64 | 11 | 50 |
3 | 13 | 1917.80 | 20 | 14.63 | 2980 | 872 | 2.92 / 467.51 | 6 | 53 |
4 | 13 | 1601.24 | 20 | 14.61 | 2559 | 748 | 3.67 / 468.26 | 6 | 58 |
5 | 13 | 947.24 | 20 | 14.74 | 1672 | 493 | 4.16 / 468.75 | 6 | 67 |
6 | 13 | 306.48 | 20 | 14.93 | 781 | 233 | 4.40 / 468.99 | 6 | 75 |
7 | 13 | 43.48 | 20 | 15.01 | 387 | 116 | 4.51 / 469.10 | 6 | 66 |
8 | 13 | 15.12 | 20 | 15.02 | 341 | 102 | 4.62 / 469.20 | 6 | 62 |
9 | 8 | -0.16 | 220 | 14.97 | 312 | 1028 | 5.64 / 470.23 | 6 | 130 |
Average= | 7.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 37 | 14.98 | 433 | 240 | 0.24 / 459.24 | 6 | 11 |
2 | 7 | 2013.72 | 40 | 14.64 | 3095 | 1812 | 2.05 / 461.06 | 28 | 50 |
3 | 13 | 1924.80 | 20 | 14.62 | 2983 | 872 | 2.92 / 461.93 | 6 | 55 |
4 | 13 | 1313.28 | 20 | 14.68 | 2151 | 632 | 3.56 / 462.56 | 6 | 64 |
5 | 13 | 1104.16 | 20 | 14.69 | 1869 | 549 | 4.11 / 463.11 | 6 | 66 |
6 | 13 | 214.32 | 20 | 14.96 | 643 | 192 | 4.30 / 463.30 | 6 | 73 |
7 | 13 | 47.64 | 20 | 15.01 | 393 | 118 | 4.42 / 463.42 | 6 | 66 |
8 | 13 | 13.24 | 20 | 15.01 | 345 | 104 | 4.52 / 463.52 | 6 | 64 |
9 | 8 | -0.12 | 223 | 14.96 | 319 | 1064 | 5.58 / 464.59 | 6 | 137 |
Average= | 7.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 37 | 14.98 | 447 | 248 | 0.25 / 453.66 | 6 | 11 |
2 | 7 | 2006.28 | 40 | 14.65 | 3091 | 1811 | 2.06 / 455.47 | 11 | 48 |
3 | 13 | 1923.52 | 20 | 14.63 | 2989 | 875 | 2.93 / 456.35 | 6 | 52 |
4 | 13 | 1517.12 | 20 | 14.63 | 2441 | 714 | 3.65 / 457.06 | 6 | 58 |
5 | 13 | 973.64 | 20 | 14.73 | 1701 | 501 | 4.15 / 457.56 | 6 | 69 |
6 | 13 | 227.92 | 20 | 14.96 | 668 | 200 | 4.35 / 457.76 | 6 | 71 |
7 | 13 | 32.92 | 20 | 15.02 | 371 | 111 | 4.46 / 457.88 | 6 | 64 |
8 | 8 | 0.08 | 244 | 14.98 | 309 | 1129 | 5.59 / 459.00 | 6 | 134 |
Average= | 7.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 37 | 14.98 | 441 | 244 | 0.24 / 448.09 | 6 | 11 |
2 | 7 | 2005.72 | 40 | 14.65 | 3075 | 1802 | 2.05 / 449.89 | 35 | 48 |
3 | 13 | 1921.04 | 20 | 14.63 | 2975 | 870 | 2.92 / 450.76 | 6 | 53 |
4 | 13 | 1498.52 | 20 | 14.64 | 2399 | 702 | 3.62 / 451.46 | 6 | 59 |
5 | 13 | 957.56 | 20 | 14.74 | 1667 | 491 | 4.11 / 451.96 | 6 | 69 |
6 | 13 | 311.40 | 20 | 14.93 | 774 | 231 | 4.34 / 452.19 | 6 | 75 |
7 | 13 | 21.92 | 20 | 15.02 | 338 | 102 | 4.44 / 452.29 | 6 | 66 |
8 | 8 | 0.04 | 242 | 14.97 | 311 | 1127 | 5.57 / 453.41 | 6 | 134 |
Average= | 7.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 37 | 14.97 | 448 | 248 | 0.25 / 442.59 | 6 | 12 |
2 | 7 | 2005.08 | 40 | 14.65 | 3080 | 1805 | 2.05 / 444.39 | 12 | 49 |
3 | 13 | 1919.56 | 20 | 14.63 | 2982 | 873 | 2.93 / 445.26 | 6 | 55 |
4 | 13 | 1492.48 | 20 | 14.64 | 2406 | 704 | 3.63 / 445.97 | 6 | 60 |
5 | 13 | 846.32 | 20 | 14.77 | 1533 | 453 | 4.08 / 446.42 | 6 | 72 |
6 | 13 | 205.48 | 20 | 14.97 | 633 | 190 | 4.27 / 446.61 | 6 | 72 |
7 | 13 | 20.40 | 20 | 15.02 | 355 | 107 | 4.38 / 446.72 | 6 | 66 |
8 | 8 | 0.04 | 240 | 14.97 | 314 | 1128 | 5.51 / 447.84 | 6 | 132 |
Average= | 7.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 37 | 14.97 | 439 | 243 | 0.24 / 437.04 | 6 | 13 |
2 | 7 | 2004.32 | 40 | 14.66 | 3085 | 1809 | 2.05 / 438.85 | 13 | 50 |
3 | 13 | 1918.08 | 20 | 14.63 | 2961 | 866 | 2.92 / 439.72 | 6 | 53 |
4 | 13 | 1501.56 | 20 | 14.64 | 2405 | 704 | 3.62 / 440.42 | 6 | 63 |
5 | 13 | 869.40 | 20 | 14.76 | 1558 | 460 | 4.08 / 440.88 | 6 | 70 |
6 | 13 | 245.16 | 20 | 14.96 | 681 | 204 | 4.29 / 441.08 | 6 | 73 |
7 | 13 | 26.28 | 20 | 15.02 | 364 | 109 | 4.40 / 441.19 | 6 | 67 |
8 | 8 | 0.00 | 242 | 14.97 | 316 | 1145 | 5.54 / 442.34 | 6 | 142 |
Average= | 7.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 37 | 14.97 | 449 | 249 | 0.25 / 431.51 | 6 | 14 |
2 | 7 | 2015.60 | 40 | 14.65 | 3088 | 1810 | 2.06 / 433.32 | 14 | 47 |
3 | 13 | 1924.60 | 20 | 14.63 | 2963 | 867 | 2.93 / 434.19 | 6 | 52 |
4 | 13 | 1503.52 | 20 | 14.64 | 2401 | 703 | 3.63 / 434.89 | 6 | 60 |
5 | 13 | 966.24 | 20 | 14.73 | 1685 | 496 | 4.12 / 435.39 | 6 | 68 |
6 | 13 | 209.68 | 20 | 14.96 | 640 | 191 | 4.32 / 435.58 | 6 | 72 |
7 | 13 | 25.60 | 20 | 15.02 | 361 | 108 | 4.42 / 435.69 | 6 | 67 |
8 | 8 | -0.08 | 240 | 14.97 | 308 | 1107 | 5.53 / 436.80 | 6 | 137 |
Average= | 7.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 37 | 14.96 | 442 | 245 | 0.24 / 425.93 | 6 | 13 |
2 | 7 | 2009.60 | 40 | 14.66 | 3095 | 1815 | 2.06 / 427.74 | 13 | 49 |
3 | 13 | 1929.36 | 20 | 14.63 | 2995 | 876 | 2.94 / 428.62 | 6 | 51 |
4 | 13 | 1495.56 | 20 | 14.65 | 2409 | 706 | 3.64 / 429.32 | 6 | 61 |
5 | 13 | 951.12 | 20 | 14.73 | 1679 | 495 | 4.14 / 429.82 | 6 | 70 |
6 | 13 | 207.88 | 20 | 14.96 | 636 | 190 | 4.33 / 430.01 | 6 | 72 |
7 | 13 | 27.12 | 20 | 15.02 | 364 | 109 | 4.44 / 430.12 | 6 | 65 |
8 | 8 | 0.08 | 242 | 14.97 | 317 | 1148 | 5.58 / 431.27 | 6 | 131 |
Average= | 7.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 37 | 14.97 | 424 | 235 | 0.23 / 420.41 | 6 | 13 |
2 | 7 | 2012.68 | 40 | 14.65 | 3090 | 1811 | 2.05 / 422.23 | 13 | 50 |
3 | 13 | 1918.60 | 20 | 14.63 | 2965 | 868 | 2.91 / 423.09 | 6 | 51 |
4 | 13 | 1405.24 | 20 | 14.66 | 2281 | 669 | 3.58 / 423.76 | 6 | 64 |
5 | 13 | 973.64 | 20 | 14.73 | 1693 | 499 | 4.08 / 424.26 | 6 | 67 |
6 | 13 | 210.28 | 20 | 14.96 | 641 | 192 | 4.27 / 424.45 | 6 | 73 |
7 | 13 | 20.76 | 20 | 15.02 | 350 | 105 | 4.38 / 424.56 | 6 | 65 |
8 | 8 | 0.00 | 240 | 14.96 | 313 | 1124 | 5.50 / 425.68 | 6 | 132 |
Average= | 7.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 37 | 14.96 | 445 | 246 | 0.25 / 414.93 | 6 | 13 |
2 | 7 | 2006.08 | 40 | 14.66 | 3070 | 1800 | 2.05 / 416.73 | 13 | 50 |
3 | 13 | 1915.76 | 20 | 14.65 | 2955 | 866 | 2.91 / 417.60 | 6 | 51 |
4 | 13 | 1410.44 | 20 | 14.67 | 2276 | 668 | 3.58 / 418.27 | 6 | 61 |
5 | 13 | 891.68 | 20 | 14.75 | 1580 | 466 | 4.05 / 418.73 | 6 | 69 |
6 | 13 | 238.80 | 20 | 14.94 | 686 | 205 | 4.25 / 418.94 | 6 | 75 |
7 | 13 | 29.84 | 20 | 15.01 | 366 | 110 | 4.36 / 419.05 | 6 | 68 |
8 | 8 | -0.08 | 242 | 14.96 | 313 | 1133 | 5.49 / 420.18 | 6 | 143 |
Average= | 7.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 37 | 14.97 | 427 | 237 | 0.24 / 409.34 | 6 | 13 |
2 | 7 | 2008.68 | 40 | 14.66 | 3081 | 1807 | 2.04 / 411.15 | 13 | 50 |
3 | 13 | 1929.36 | 20 | 14.64 | 2981 | 873 | 2.92 / 412.02 | 6 | 51 |
4 | 13 | 1516.48 | 20 | 14.64 | 2429 | 711 | 3.63 / 412.74 | 6 | 60 |
5 | 13 | 885.08 | 20 | 14.76 | 1575 | 465 | 4.09 / 413.20 | 6 | 69 |
6 | 13 | 349.24 | 20 | 14.91 | 849 | 253 | 4.35 / 413.45 | 6 | 76 |
7 | 13 | 30.36 | 20 | 15.01 | 364 | 109 | 4.45 / 413.56 | 6 | 66 |
8 | 8 | 0.00 | 242 | 14.97 | 310 | 1123 | 5.58 / 414.69 | 6 | 130 |
Average= | 7.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 37 | 14.96 | 428 | 237 | 0.24 / 403.72 | 6 | 13 |
2 | 7 | 2012.84 | 40 | 14.67 | 3090 | 1813 | 2.05 / 405.54 | 13 | 49 |
3 | 13 | 1917.72 | 20 | 14.64 | 2955 | 865 | 2.92 / 406.40 | 6 | 52 |
4 | 13 | 1589.92 | 20 | 14.63 | 2513 | 735 | 3.65 / 407.14 | 6 | 59 |
5 | 13 | 1035.84 | 20 | 14.72 | 1765 | 520 | 4.17 / 407.66 | 6 | 69 |
6 | 13 | 281.20 | 20 | 14.94 | 729 | 218 | 4.39 / 407.88 | 6 | 74 |
7 | 13 | 39.28 | 20 | 15.01 | 377 | 113 | 4.50 / 407.99 | 6 | 66 |
8 | 8 | 0.04 | 242 | 14.97 | 309 | 1119 | 5.62 / 409.11 | 6 | 132 |
Average= | 7.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 37 | 14.96 | 452 | 250 | 0.25 / 398.13 | 6 | 14 |
2 | 7 | 2003.92 | 40 | 14.66 | 3076 | 1804 | 2.05 / 399.93 | 14 | 49 |
3 | 13 | 1909.16 | 20 | 14.64 | 2952 | 864 | 2.92 / 400.80 | 6 | 55 |
4 | 13 | 1594.80 | 20 | 14.62 | 2534 | 741 | 3.66 / 401.54 | 6 | 59 |
5 | 13 | 949.76 | 20 | 14.74 | 1654 | 488 | 4.15 / 402.03 | 6 | 69 |
6 | 13 | 285.76 | 20 | 14.93 | 745 | 222 | 4.37 / 402.25 | 6 | 73 |
7 | 13 | 39.36 | 20 | 15.01 | 382 | 115 | 4.48 / 402.36 | 6 | 66 |
8 | 8 | 0.00 | 242 | 14.96 | 310 | 1122 | 5.61 / 403.49 | 6 | 135 |
Average= | 7.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 37 | 14.96 | 451 | 250 | 0.25 / 392.56 | 6 | 14 |
2 | 7 | 2006.76 | 40 | 14.66 | 3089 | 1811 | 2.06 / 394.37 | 14 | 50 |
3 | 13 | 1918.20 | 20 | 14.64 | 2974 | 871 | 2.93 / 395.24 | 6 | 53 |
4 | 13 | 1506.68 | 20 | 14.64 | 2427 | 711 | 3.64 / 395.95 | 6 | 62 |
5 | 13 | 878.76 | 20 | 14.75 | 1579 | 466 | 4.11 / 396.42 | 6 | 70 |
6 | 13 | 251.56 | 20 | 14.95 | 699 | 209 | 4.32 / 396.63 | 6 | 73 |
7 | 13 | 32.56 | 20 | 15.01 | 371 | 111 | 4.43 / 396.74 | 6 | 66 |
8 | 8 | -0.04 | 240 | 14.96 | 318 | 1142 | 5.57 / 397.88 | 6 | 130 |
Average= | 7.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 37 | 14.96 | 433 | 240 | 0.24 / 387.00 | 6 | 13 |
2 | 7 | 2006.04 | 40 | 14.67 | 3083 | 1809 | 2.05 / 388.81 | 52 | 49 |
3 | 13 | 1921.44 | 20 | 14.65 | 2971 | 871 | 2.92 / 389.68 | 6 | 55 |
4 | 13 | 1512.36 | 20 | 14.65 | 2414 | 707 | 3.63 / 390.38 | 6 | 61 |
5 | 13 | 875.64 | 20 | 14.76 | 1565 | 462 | 4.09 / 390.85 | 6 | 70 |
6 | 13 | 236.04 | 20 | 14.95 | 677 | 202 | 4.29 / 391.05 | 6 | 73 |
7 | 13 | 31.76 | 20 | 15.02 | 372 | 112 | 4.40 / 391.16 | 6 | 65 |
8 | 8 | -0.08 | 242 | 14.96 | 318 | 1151 | 5.55 / 392.31 | 6 | 141 |
Average= | 7.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 37 | 14.97 | 451 | 250 | 0.25 / 381.36 | 6 | 15 |
2 | 7 | 2011.92 | 40 | 14.67 | 3081 | 1808 | 2.06 / 383.17 | 15 | 49 |
3 | 13 | 1913.44 | 20 | 14.65 | 2960 | 867 | 2.93 / 384.04 | 6 | 53 |
4 | 13 | 1589.64 | 20 | 14.64 | 2527 | 740 | 3.66 / 384.78 | 6 | 59 |
5 | 13 | 939.32 | 20 | 14.75 | 1635 | 482 | 4.15 / 385.26 | 6 | 68 |
6 | 13 | 292.96 | 20 | 14.93 | 763 | 228 | 4.38 / 385.49 | 6 | 74 |
7 | 13 | 39.64 | 20 | 15.01 | 382 | 115 | 4.49 / 385.60 | 6 | 66 |
8 | 8 | -0.12 | 242 | 14.96 | 319 | 1155 | 5.64 / 386.76 | 6 | 130 |
Average= | 7.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 37 | 14.96 | 449 | 249 | 0.25 / 375.72 | 6 | 16 |
2 | 7 | 2008.20 | 40 | 14.67 | 3098 | 1818 | 2.07 / 377.54 | 16 | 50 |
3 | 13 | 1914.16 | 20 | 14.66 | 2970 | 871 | 2.94 / 378.41 | 6 | 54 |
4 | 13 | 1501.20 | 20 | 14.65 | 2419 | 709 | 3.65 / 379.12 | 6 | 62 |
5 | 13 | 959.08 | 20 | 14.74 | 1680 | 495 | 4.14 / 379.62 | 6 | 73 |
6 | 13 | 291.40 | 20 | 14.93 | 762 | 228 | 4.37 / 379.84 | 6 | 73 |
7 | 13 | 38.28 | 20 | 15.02 | 379 | 114 | 4.48 / 379.96 | 6 | 66 |
8 | 8 | 0.04 | 242 | 14.96 | 319 | 1155 | 5.64 / 381.11 | 6 | 140 |
Average= | 7.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 37 | 14.97 | 451 | 250 | 0.25 / 369.99 | 6 | 15 |
2 | 7 | 2007.92 | 40 | 14.68 | 3090 | 1814 | 2.06 / 371.80 | 15 | 49 |
3 | 13 | 1932.16 | 20 | 14.65 | 2981 | 873 | 2.94 / 372.68 | 6 | 53 |
4 | 13 | 1508.84 | 20 | 14.66 | 2409 | 706 | 3.64 / 373.38 | 6 | 60 |
5 | 13 | 1187.44 | 20 | 14.68 | 1971 | 579 | 4.22 / 373.96 | 6 | 67 |
6 | 13 | 398.72 | 20 | 14.90 | 902 | 269 | 4.49 / 374.23 | 6 | 75 |
7 | 13 | 32.88 | 20 | 15.02 | 355 | 107 | 4.60 / 374.34 | 6 | 67 |
8 | 8 | 0.04 | 240 | 14.96 | 317 | 1138 | 5.74 / 375.47 | 6 | 131 |
Average= | 7.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 37 | 14.97 | 460 | 255 | 0.25 / 364.34 | 6 | 15 |
2 | 7 | 2011.96 | 40 | 14.67 | 3095 | 1816 | 2.07 / 366.16 | 15 | 51 |
3 | 13 | 1914.24 | 20 | 14.65 | 2966 | 869 | 2.94 / 367.03 | 6 | 54 |
4 | 13 | 1589.76 | 20 | 14.64 | 2519 | 738 | 3.68 / 367.77 | 6 | 61 |
5 | 13 | 1036.16 | 20 | 14.73 | 1776 | 523 | 4.20 / 368.29 | 6 | 68 |
6 | 13 | 251.48 | 20 | 14.96 | 683 | 204 | 4.41 / 368.49 | 6 | 73 |
7 | 13 | 29.60 | 20 | 15.03 | 348 | 105 | 4.51 / 368.60 | 6 | 65 |
8 | 8 | 0.00 | 240 | 14.97 | 317 | 1139 | 5.65 / 369.74 | 6 | 131 |
Average= | 7.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 37 | 14.97 | 447 | 248 | 0.25 / 358.63 | 6 | 18 |
2 | 7 | 2006.68 | 40 | 14.68 | 3080 | 1809 | 2.06 / 360.44 | 18 | 49 |
3 | 13 | 1913.16 | 20 | 14.67 | 2954 | 867 | 2.92 / 361.31 | 6 | 55 |
4 | 13 | 1706.96 | 20 | 14.62 | 2690 | 787 | 3.71 / 362.09 | 6 | 59 |
5 | 13 | 1023.36 | 20 | 14.73 | 1771 | 522 | 4.23 / 362.62 | 6 | 70 |
6 | 13 | 261.56 | 20 | 14.96 | 713 | 213 | 4.44 / 362.83 | 6 | 72 |
7 | 13 | 33.44 | 20 | 15.03 | 372 | 112 | 4.56 / 362.94 | 6 | 65 |
8 | 8 | 0.08 | 242 | 14.98 | 317 | 1149 | 5.71 / 364.09 | 6 | 133 |
Average= | 7.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 37 | 14.98 | 438 | 243 | 0.24 / 353.03 | 6 | 16 |
2 | 7 | 2004.56 | 40 | 14.69 | 3085 | 1813 | 2.06 / 354.84 | 16 | 49 |
3 | 13 | 1919.48 | 20 | 14.66 | 2965 | 869 | 2.92 / 355.71 | 6 | 53 |
4 | 13 | 1498.56 | 20 | 14.67 | 2407 | 706 | 3.63 / 356.42 | 6 | 61 |
5 | 13 | 863.20 | 20 | 14.78 | 1556 | 460 | 4.09 / 356.88 | 6 | 71 |
6 | 13 | 334.52 | 20 | 14.93 | 826 | 247 | 4.34 / 357.13 | 6 | 74 |
7 | 13 | 24.68 | 20 | 15.03 | 359 | 108 | 4.45 / 357.23 | 6 | 65 |
8 | 8 | 0.00 | 242 | 14.98 | 317 | 1149 | 5.59 / 358.38 | 6 | 137 |
Average= | 7.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 37 | 14.97 | 460 | 255 | 0.25 / 347.50 | 6 | 20 |
2 | 7 | 2009.76 | 41 | 14.68 | 3091 | 1860 | 2.12 / 349.36 | 20 | 51 |
3 | 13 | 1925.60 | 20 | 14.66 | 2986 | 875 | 2.99 / 350.24 | 6 | 54 |
4 | 13 | 1403.68 | 20 | 14.69 | 2279 | 670 | 3.66 / 350.91 | 6 | 63 |
5 | 13 | 886.88 | 20 | 14.77 | 1576 | 466 | 4.13 / 351.37 | 6 | 69 |
6 | 13 | 157.84 | 20 | 14.99 | 563 | 169 | 4.29 / 351.54 | 6 | 70 |
7 | 13 | 19.40 | 20 | 15.03 | 354 | 106 | 4.40 / 351.65 | 6 | 65 |
8 | 8 | 0.08 | 240 | 14.98 | 318 | 1143 | 5.54 / 352.79 | 6 | 134 |
Average= | 8.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 37 | 14.98 | 456 | 253 | 0.25 / 342.00 | 6 | 18 |
2 | 7 | 2016.24 | 40 | 14.68 | 3092 | 1816 | 2.07 / 343.82 | 18 | 47 |
3 | 13 | 1931.60 | 20 | 14.67 | 2978 | 874 | 2.94 / 344.69 | 6 | 53 |
4 | 13 | 1315.84 | 20 | 14.71 | 2145 | 631 | 3.57 / 345.32 | 6 | 62 |
5 | 13 | 905.60 | 20 | 14.77 | 1583 | 468 | 4.04 / 345.79 | 6 | 67 |
6 | 13 | 260.24 | 20 | 14.96 | 699 | 209 | 4.25 / 346.00 | 6 | 74 |
7 | 13 | 23.44 | 20 | 15.04 | 346 | 104 | 4.35 / 346.10 | 6 | 69 |
8 | 8 | -0.12 | 238 | 14.98 | 320 | 1141 | 5.49 / 347.25 | 6 | 134 |
Average= | 8.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 37 | 15.00 | 448 | 249 | 0.25 / 336.34 | 6 | 18 |
2 | 7 | 2004.84 | 41 | 14.68 | 3082 | 1855 | 2.10 / 338.20 | 18 | 51 |
3 | 13 | 1915.76 | 20 | 14.67 | 2961 | 869 | 2.97 / 339.07 | 6 | 53 |
4 | 13 | 1494.92 | 20 | 14.68 | 2391 | 702 | 3.67 / 339.77 | 6 | 62 |
5 | 13 | 1060.16 | 20 | 14.73 | 1805 | 532 | 4.21 / 340.30 | 6 | 69 |
6 | 13 | 279.04 | 20 | 14.96 | 726 | 217 | 4.42 / 340.52 | 6 | 73 |
7 | 13 | 32.68 | 20 | 15.04 | 354 | 106 | 4.53 / 340.62 | 6 | 67 |
8 | 8 | -0.04 | 240 | 14.99 | 313 | 1126 | 5.66 / 341.75 | 6 | 135 |
Average= | 8.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 37 | 14.99 | 457 | 253 | 0.25 / 330.88 | 6 | 19 |
2 | 7 | 2013.04 | 41 | 14.68 | 3101 | 1866 | 2.12 / 332.75 | 19 | 48 |
3 | 13 | 1919.56 | 20 | 14.67 | 2968 | 871 | 2.99 / 333.62 | 6 | 51 |
4 | 13 | 1401.76 | 20 | 14.70 | 2274 | 669 | 3.66 / 334.29 | 6 | 61 |
5 | 13 | 785.48 | 20 | 14.82 | 1433 | 425 | 4.08 / 334.71 | 6 | 71 |
6 | 13 | 150.36 | 20 | 15.02 | 544 | 163 | 4.25 / 334.87 | 6 | 70 |
7 | 13 | 19.08 | 20 | 15.05 | 351 | 106 | 4.35 / 334.98 | 6 | 66 |
8 | 8 | 0.04 | 238 | 15.00 | 312 | 1114 | 5.47 / 336.09 | 6 | 132 |
Average= | 8.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 37 | 15.00 | 449 | 249 | 0.25 / 325.27 | 6 | 18 |
2 | 7 | 2004.20 | 40 | 14.70 | 3065 | 1802 | 2.05 / 327.07 | 18 | 50 |
3 | 13 | 1921.64 | 20 | 14.68 | 2968 | 871 | 2.92 / 327.94 | 6 | 53 |
4 | 13 | 1514.32 | 20 | 14.68 | 2442 | 717 | 3.64 / 328.66 | 6 | 63 |
5 | 13 | 981.76 | 20 | 14.76 | 1720 | 508 | 4.15 / 329.17 | 6 | 70 |
6 | 13 | 225.00 | 20 | 14.99 | 663 | 199 | 4.35 / 329.36 | 6 | 74 |
7 | 13 | 21.24 | 20 | 15.05 | 358 | 108 | 4.45 / 329.47 | 6 | 68 |
8 | 8 | -0.04 | 240 | 15.00 | 321 | 1156 | 5.61 / 330.63 | 6 | 140 |
Average= | 8.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 37 | 15.00 | 452 | 251 | 0.25 / 319.61 | 6 | 17 |
2 | 7 | 2003.12 | 40 | 14.70 | 3072 | 1806 | 2.06 / 321.42 | 17 | 50 |
3 | 13 | 1910.68 | 20 | 14.68 | 2965 | 871 | 2.93 / 322.29 | 6 | 52 |
4 | 13 | 1703.96 | 20 | 14.65 | 2677 | 784 | 3.71 / 323.07 | 6 | 58 |
5 | 13 | 931.96 | 20 | 14.80 | 1624 | 481 | 4.19 / 323.56 | 6 | 70 |
6 | 13 | 280.96 | 20 | 14.98 | 735 | 220 | 4.41 / 323.78 | 6 | 75 |
7 | 13 | 16.12 | 20 | 15.07 | 332 | 100 | 4.51 / 323.88 | 6 | 68 |
8 | 8 | 0.00 | 240 | 15.01 | 317 | 1142 | 5.66 / 325.02 | 6 | 131 |
Average= | 8.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 37 | 15.01 | 450 | 250 | 0.25 / 314.06 | 6 | 16 |
2 | 7 | 2004.96 | 40 | 14.70 | 3085 | 1814 | 2.06 / 315.87 | 16 | 49 |
3 | 13 | 1919.04 | 20 | 14.69 | 2965 | 871 | 2.94 / 316.74 | 6 | 51 |
4 | 13 | 1405.80 | 20 | 14.71 | 2272 | 668 | 3.60 / 317.41 | 6 | 63 |
5 | 13 | 981.60 | 20 | 14.77 | 1716 | 507 | 4.11 / 317.92 | 6 | 71 |
6 | 13 | 220.36 | 20 | 15.00 | 652 | 196 | 4.31 / 318.11 | 6 | 74 |
7 | 13 | 21.12 | 20 | 15.06 | 354 | 107 | 4.41 / 318.22 | 6 | 68 |
8 | 8 | -0.08 | 238 | 15.01 | 320 | 1143 | 5.56 / 319.36 | 6 | 129 |
Average= | 8.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 37 | 15.01 | 448 | 249 | 0.25 / 308.52 | 6 | 15 |
2 | 7 | 2003.44 | 41 | 14.70 | 3081 | 1857 | 2.11 / 310.38 | 15 | 50 |
3 | 13 | 1906.76 | 20 | 14.69 | 2937 | 863 | 2.97 / 311.24 | 6 | 53 |
4 | 13 | 1476.00 | 20 | 14.70 | 2361 | 694 | 3.66 / 311.93 | 6 | 60 |
5 | 13 | 941.40 | 20 | 14.79 | 1638 | 485 | 4.15 / 312.42 | 6 | 68 |
6 | 13 | 179.44 | 20 | 15.03 | 578 | 174 | 4.32 / 312.59 | 6 | 73 |
7 | 13 | 16.64 | 20 | 15.07 | 332 | 100 | 4.42 / 312.69 | 6 | 67 |
8 | 8 | 0.08 | 238 | 15.02 | 312 | 1115 | 5.54 / 313.81 | 6 | 136 |
Average= | 8.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 37 | 15.02 | 449 | 250 | 0.25 / 302.83 | 6 | 16 |
2 | 7 | 2011.24 | 40 | 14.71 | 3092 | 1819 | 2.07 / 304.65 | 16 | 49 |
3 | 13 | 1919.88 | 20 | 14.68 | 2988 | 877 | 2.95 / 305.53 | 6 | 53 |
4 | 13 | 1507.80 | 20 | 14.70 | 2414 | 710 | 3.66 / 306.24 | 6 | 61 |
5 | 13 | 1070.52 | 20 | 14.76 | 1819 | 537 | 4.19 / 306.78 | 6 | 68 |
6 | 13 | 390.08 | 20 | 14.95 | 893 | 267 | 4.46 / 307.04 | 6 | 76 |
7 | 13 | 15.40 | 20 | 15.07 | 329 | 99 | 4.56 / 307.14 | 6 | 66 |
8 | 8 | -0.04 | 240 | 15.02 | 313 | 1128 | 5.69 / 308.27 | 6 | 134 |
Average= | 8.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 37 | 15.02 | 452 | 251 | 0.25 / 297.17 | 6 | 13 |
2 | 7 | 2015.48 | 40 | 14.71 | 3093 | 1820 | 2.07 / 298.99 | 13 | 47 |
3 | 13 | 1923.52 | 20 | 14.69 | 2978 | 875 | 2.95 / 299.87 | 6 | 52 |
4 | 13 | 1601.44 | 20 | 14.68 | 2551 | 749 | 3.70 / 300.62 | 6 | 62 |
5 | 13 | 1056.52 | 20 | 14.77 | 1798 | 531 | 4.23 / 301.15 | 6 | 67 |
6 | 13 | 189.00 | 20 | 15.03 | 610 | 183 | 4.41 / 301.33 | 6 | 73 |
7 | 13 | 20.20 | 20 | 15.08 | 356 | 107 | 4.52 / 301.44 | 6 | 66 |
8 | 8 | 0.00 | 240 | 15.02 | 318 | 1146 | 5.66 / 302.58 | 6 | 135 |
Average= | 8.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 37 | 15.03 | 451 | 251 | 0.25 / 291.71 | 6 | 13 |
2 | 7 | 2005.32 | 40 | 14.71 | 3087 | 1816 | 2.07 / 293.53 | 27 | 50 |
3 | 13 | 1917.24 | 20 | 14.69 | 2971 | 873 | 2.94 / 294.40 | 6 | 52 |
4 | 13 | 1302.48 | 20 | 14.75 | 2139 | 631 | 3.57 / 295.03 | 6 | 64 |
5 | 13 | 892.20 | 20 | 14.81 | 1593 | 472 | 4.04 / 295.51 | 6 | 68 |
6 | 13 | 142.56 | 20 | 15.04 | 539 | 162 | 4.21 / 295.67 | 6 | 71 |
7 | 13 | 16.48 | 20 | 15.08 | 353 | 106 | 4.31 / 295.78 | 6 | 64 |
8 | 8 | -0.04 | 238 | 15.03 | 320 | 1145 | 5.46 / 296.92 | 6 | 130 |
Average= | 8.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 36 | 15.04 | 442 | 239 | 0.24 / 286.18 | 6 | 12 |
2 | 7 | 2005.36 | 40 | 14.70 | 3091 | 1818 | 2.06 / 288.00 | 12 | 53 |
3 | 13 | 1915.28 | 20 | 14.69 | 2972 | 873 | 2.93 / 288.87 | 6 | 55 |
4 | 13 | 1498.08 | 20 | 14.70 | 2397 | 705 | 3.63 / 289.58 | 6 | 62 |
5 | 13 | 944.40 | 20 | 14.81 | 1635 | 484 | 4.12 / 290.06 | 6 | 70 |
6 | 13 | 195.68 | 20 | 15.03 | 605 | 182 | 4.30 / 290.24 | 6 | 73 |
7 | 13 | 24.44 | 20 | 15.09 | 346 | 104 | 4.41 / 290.35 | 6 | 66 |
8 | 8 | -0.04 | 240 | 15.03 | 309 | 1115 | 5.52 / 291.46 | 6 | 137 |
Average= | 8.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 37 | 15.04 | 426 | 237 | 0.24 / 280.60 | 6 | 11 |
2 | 7 | 2014.60 | 41 | 14.70 | 3088 | 1861 | 2.10 / 282.46 | 11 | 48 |
3 | 13 | 1921.20 | 20 | 14.69 | 2982 | 876 | 2.97 / 283.34 | 6 | 56 |
4 | 13 | 1484.20 | 20 | 14.71 | 2385 | 702 | 3.68 / 284.04 | 6 | 60 |
5 | 13 | 942.80 | 20 | 14.82 | 1634 | 484 | 4.16 / 284.52 | 6 | 69 |
6 | 13 | 182.48 | 20 | 15.04 | 585 | 176 | 4.34 / 284.70 | 6 | 74 |
7 | 13 | 37.84 | 20 | 15.08 | 368 | 111 | 4.45 / 284.81 | 6 | 66 |
8 | 8 | -0.04 | 240 | 15.04 | 314 | 1133 | 5.58 / 285.94 | 6 | 135 |
Average= | 8.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 37 | 15.06 | 427 | 238 | 0.24 / 274.94 | 6 | 11 |
2 | 7 | 2004.64 | 40 | 14.72 | 3086 | 1817 | 2.05 / 276.76 | 11 | 50 |
3 | 13 | 1919.16 | 20 | 14.70 | 2982 | 877 | 2.93 / 277.64 | 6 | 51 |
4 | 13 | 1499.68 | 20 | 14.71 | 2407 | 708 | 3.64 / 278.35 | 6 | 61 |
5 | 13 | 1050.80 | 20 | 14.79 | 1794 | 531 | 4.17 / 278.88 | 6 | 71 |
6 | 13 | 266.52 | 20 | 15.01 | 729 | 219 | 4.39 / 279.09 | 6 | 75 |
7 | 13 | 37.68 | 20 | 15.08 | 377 | 114 | 4.50 / 279.21 | 6 | 67 |
8 | 13 | 12.68 | 20 | 15.09 | 339 | 102 | 4.61 / 279.31 | 6 | 65 |
9 | 8 | 0.08 | 223 | 15.03 | 314 | 1052 | 5.66 / 280.36 | 6 | 135 |
Average= | 9.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 37 | 15.06 | 426 | 237 | 0.24 / 269.36 | 6 | 12 |
2 | 7 | 2012.60 | 40 | 14.71 | 3102 | 1825 | 2.06 / 271.18 | 12 | 49 |
3 | 13 | 1918.84 | 20 | 14.70 | 2966 | 872 | 2.93 / 272.05 | 6 | 55 |
4 | 13 | 1495.64 | 20 | 14.71 | 2392 | 704 | 3.64 / 272.76 | 6 | 61 |
5 | 13 | 950.72 | 20 | 14.83 | 1643 | 487 | 4.13 / 273.24 | 6 | 68 |
6 | 13 | 294.24 | 20 | 15.01 | 755 | 227 | 4.35 / 273.47 | 6 | 75 |
7 | 13 | 41.12 | 20 | 15.09 | 370 | 112 | 4.46 / 273.58 | 6 | 67 |
8 | 13 | 15.00 | 20 | 15.09 | 328 | 99 | 4.56 / 273.68 | 6 | 64 |
9 | 8 | -0.12 | 223 | 15.05 | 305 | 1024 | 5.59 / 274.71 | 6 | 137 |
Average= | 9.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 36 | 15.06 | 444 | 241 | 0.24 / 263.88 | 6 | 11 |
2 | 7 | 2004.92 | 40 | 14.71 | 3086 | 1816 | 2.06 / 265.69 | 11 | 48 |
3 | 13 | 1913.68 | 20 | 14.69 | 2972 | 873 | 2.93 / 266.57 | 6 | 52 |
4 | 13 | 1383.72 | 20 | 14.74 | 2250 | 663 | 3.59 / 267.23 | 6 | 64 |
5 | 13 | 855.24 | 20 | 14.85 | 1543 | 458 | 4.05 / 267.69 | 6 | 72 |
6 | 13 | 202.64 | 20 | 15.05 | 623 | 188 | 4.24 / 267.87 | 6 | 73 |
7 | 13 | 42.88 | 20 | 15.09 | 389 | 117 | 4.36 / 267.99 | 6 | 67 |
8 | 13 | 14.48 | 20 | 15.09 | 342 | 103 | 4.46 / 268.10 | 6 | 65 |
9 | 8 | 0.00 | 218 | 15.05 | 312 | 1024 | 5.48 / 269.12 | 6 | 129 |
Average= | 9.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 36 | 15.06 | 425 | 230 | 0.23 / 258.31 | 6 | 12 |
2 | 7 | 2007.04 | 40 | 14.72 | 3084 | 1816 | 2.05 / 260.12 | 12 | 49 |
3 | 13 | 1925.72 | 20 | 14.70 | 2985 | 878 | 2.92 / 261.00 | 6 | 53 |
4 | 13 | 1506.92 | 20 | 14.72 | 2408 | 709 | 3.63 / 261.71 | 6 | 60 |
5 | 13 | 955.96 | 20 | 14.83 | 1665 | 494 | 4.13 / 262.20 | 6 | 68 |
6 | 13 | 196.12 | 20 | 15.06 | 606 | 183 | 4.31 / 262.39 | 6 | 73 |
7 | 13 | 26.76 | 20 | 15.10 | 363 | 110 | 4.42 / 262.50 | 6 | 65 |
8 | 8 | 0.04 | 242 | 15.06 | 313 | 1141 | 5.56 / 263.64 | 6 | 134 |
Average= | 9.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 36 | 15.06 | 440 | 239 | 0.24 / 252.75 | 6 | 12 |
2 | 7 | 2012.68 | 40 | 14.72 | 3098 | 1824 | 2.06 / 254.58 | 12 | 47 |
3 | 13 | 1922.32 | 20 | 14.70 | 2992 | 880 | 2.94 / 255.46 | 6 | 53 |
4 | 13 | 1413.96 | 20 | 14.75 | 2287 | 675 | 3.62 / 256.13 | 6 | 62 |
5 | 13 | 992.12 | 20 | 14.82 | 1716 | 509 | 4.13 / 256.64 | 6 | 69 |
6 | 13 | 226.12 | 20 | 15.05 | 654 | 197 | 4.32 / 256.84 | 6 | 73 |
7 | 13 | 32.60 | 20 | 15.11 | 359 | 108 | 4.43 / 256.95 | 6 | 67 |
8 | 8 | 0.00 | 242 | 15.06 | 310 | 1130 | 5.56 / 258.08 | 6 | 130 |
Average= | 9.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 36 | 15.07 | 450 | 244 | 0.24 / 247.18 | 6 | 12 |
2 | 7 | 2005.88 | 40 | 14.72 | 3088 | 1818 | 2.06 / 249.00 | 12 | 49 |
3 | 13 | 1912.32 | 20 | 14.71 | 2962 | 871 | 2.93 / 249.87 | 6 | 54 |
4 | 13 | 1481.04 | 20 | 14.74 | 2377 | 701 | 3.63 / 250.57 | 6 | 61 |
5 | 13 | 940.32 | 20 | 14.84 | 1637 | 486 | 4.12 / 251.06 | 6 | 70 |
6 | 13 | 270.00 | 20 | 15.03 | 718 | 216 | 4.34 / 251.28 | 6 | 76 |
7 | 13 | 29.48 | 20 | 15.11 | 355 | 107 | 4.44 / 251.38 | 6 | 68 |
8 | 13 | 10.04 | 20 | 15.11 | 324 | 98 | 4.54 / 251.48 | 6 | 67 |
9 | 8 | -0.08 | 220 | 15.06 | 312 | 1034 | 5.58 / 252.52 | 6 | 132 |
Average= | 9.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 36 | 15.07 | 453 | 246 | 0.25 / 241.71 | 6 | 13 |
2 | 7 | 2004.64 | 40 | 14.72 | 3076 | 1811 | 2.06 / 243.52 | 13 | 50 |
3 | 13 | 1916.28 | 20 | 14.70 | 2975 | 875 | 2.93 / 244.39 | 6 | 54 |
4 | 13 | 1387.44 | 20 | 14.77 | 2248 | 664 | 3.60 / 245.06 | 6 | 62 |
5 | 13 | 859.40 | 20 | 14.87 | 1524 | 453 | 4.05 / 245.51 | 6 | 69 |
6 | 13 | 213.80 | 20 | 15.06 | 632 | 190 | 4.24 / 245.70 | 6 | 73 |
7 | 13 | 26.60 | 20 | 15.12 | 347 | 105 | 4.34 / 245.80 | 6 | 67 |
8 | 8 | 0.00 | 240 | 15.07 | 314 | 1136 | 5.48 / 246.94 | 6 | 135 |
Average= | 9.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 36 | 15.08 | 430 | 233 | 0.23 / 236.07 | 6 | 12 |
2 | 7 | 2012.92 | 40 | 14.73 | 3082 | 1816 | 2.05 / 237.89 | 12 | 46 |
3 | 13 | 1922.28 | 20 | 14.71 | 2991 | 880 | 2.93 / 238.77 | 6 | 55 |
4 | 13 | 1608.32 | 20 | 14.71 | 2542 | 748 | 3.68 / 239.52 | 6 | 59 |
5 | 13 | 852.00 | 20 | 14.88 | 1519 | 452 | 4.13 / 239.97 | 6 | 70 |
6 | 13 | 318.96 | 20 | 15.02 | 792 | 238 | 4.37 / 240.21 | 6 | 76 |
7 | 13 | 24.16 | 20 | 15.12 | 350 | 106 | 4.47 / 240.31 | 6 | 67 |
8 | 8 | 0.00 | 242 | 15.07 | 315 | 1149 | 5.62 / 241.46 | 6 | 134 |
Average= | 10.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 36 | 15.07 | 449 | 244 | 0.24 / 230.55 | 6 | 13 |
2 | 7 | 2004.48 | 40 | 14.74 | 3083 | 1818 | 2.06 / 232.36 | 13 | 50 |
3 | 13 | 1918.88 | 20 | 14.71 | 2978 | 876 | 2.94 / 233.24 | 6 | 53 |
4 | 13 | 1497.60 | 20 | 14.74 | 2410 | 710 | 3.65 / 233.95 | 6 | 64 |
5 | 13 | 850.76 | 20 | 14.88 | 1511 | 450 | 4.10 / 234.40 | 6 | 69 |
6 | 13 | 207.24 | 20 | 15.07 | 626 | 189 | 4.29 / 234.59 | 6 | 73 |
7 | 13 | 27.80 | 20 | 15.13 | 348 | 105 | 4.39 / 234.69 | 6 | 66 |
8 | 8 | 0.04 | 242 | 15.08 | 314 | 1146 | 5.54 / 235.84 | 6 | 135 |
Average= | 10.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 36 | 15.08 | 450 | 244 | 0.24 / 224.84 | 6 | 14 |
2 | 7 | 2005.28 | 40 | 14.74 | 3076 | 1814 | 2.06 / 226.65 | 14 | 50 |
3 | 13 | 1918.88 | 20 | 14.72 | 2971 | 875 | 2.93 / 227.53 | 6 | 56 |
4 | 13 | 1499.76 | 20 | 14.75 | 2398 | 707 | 3.64 / 228.23 | 6 | 61 |
5 | 13 | 1052.92 | 20 | 14.82 | 1792 | 531 | 4.17 / 228.76 | 6 | 67 |
6 | 13 | 368.68 | 20 | 15.01 | 864 | 259 | 4.43 / 229.02 | 6 | 76 |
7 | 13 | 60.04 | 20 | 15.11 | 400 | 121 | 4.55 / 229.14 | 6 | 68 |
8 | 13 | 12.84 | 20 | 15.12 | 327 | 99 | 4.65 / 229.24 | 6 | 69 |
9 | 8 | -0.04 | 220 | 15.07 | 319 | 1058 | 5.71 / 230.30 | 6 | 130 |
Average= | 10.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 36 | 15.09 | 442 | 240 | 0.24 / 219.32 | 6 | 12 |
2 | 7 | 2005.08 | 40 | 14.73 | 3086 | 1818 | 2.06 / 221.14 | 12 | 52 |
3 | 13 | 1916.00 | 20 | 14.71 | 2985 | 878 | 2.94 / 222.02 | 6 | 52 |
4 | 13 | 1391.56 | 20 | 14.77 | 2273 | 671 | 3.61 / 222.69 | 6 | 63 |
5 | 13 | 953.16 | 20 | 14.85 | 1682 | 500 | 4.11 / 223.19 | 6 | 69 |
6 | 13 | 95.60 | 20 | 15.12 | 474 | 143 | 4.25 / 223.34 | 6 | 68 |
7 | 13 | 20.00 | 20 | 15.13 | 355 | 107 | 4.36 / 223.44 | 6 | 64 |
8 | 8 | -0.04 | 240 | 15.08 | 318 | 1151 | 5.51 / 224.59 | 6 | 137 |
Average= | 10.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 36 | 15.08 | 445 | 242 | 0.24 / 213.80 | 6 | 14 |
2 | 7 | 2006.96 | 41 | 14.73 | 3083 | 1862 | 2.10 / 215.66 | 14 | 50 |
3 | 13 | 1924.88 | 20 | 14.72 | 2975 | 876 | 2.98 / 216.54 | 6 | 53 |
4 | 13 | 1315.52 | 20 | 14.79 | 2156 | 638 | 3.62 / 217.17 | 6 | 66 |
5 | 13 | 1002.64 | 20 | 14.84 | 1724 | 512 | 4.13 / 217.69 | 6 | 71 |
6 | 13 | 124.04 | 20 | 15.11 | 498 | 150 | 4.28 / 217.84 | 6 | 71 |
7 | 13 | 13.60 | 20 | 15.14 | 330 | 100 | 4.38 / 217.94 | 6 | 66 |
8 | 8 | 0.00 | 240 | 15.09 | 317 | 1148 | 5.53 / 219.08 | 6 | 136 |
Average= | 10.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 36 | 15.09 | 446 | 242 | 0.24 / 208.14 | 6 | 13 |
2 | 7 | 2003.88 | 40 | 14.75 | 3075 | 1814 | 2.06 / 209.95 | 13 | 49 |
3 | 13 | 1910.16 | 20 | 14.73 | 2950 | 869 | 2.93 / 210.82 | 6 | 54 |
4 | 13 | 1486.80 | 20 | 14.76 | 2377 | 702 | 3.63 / 211.52 | 6 | 61 |
5 | 13 | 1032.76 | 20 | 14.84 | 1773 | 526 | 4.15 / 212.05 | 6 | 71 |
6 | 13 | 362.36 | 20 | 15.03 | 861 | 259 | 4.41 / 212.31 | 6 | 77 |
7 | 13 | 13.60 | 20 | 15.14 | 330 | 100 | 4.51 / 212.41 | 6 | 67 |
8 | 8 | -0.08 | 240 | 15.08 | 317 | 1147 | 5.66 / 213.56 | 6 | 131 |
Average= | 11.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 36 | 15.09 | 445 | 242 | 0.24 / 202.69 | 6 | 13 |
2 | 7 | 2005.36 | 40 | 14.73 | 3097 | 1825 | 2.07 / 204.51 | 13 | 50 |
3 | 13 | 1917.04 | 20 | 14.71 | 2977 | 876 | 2.94 / 205.39 | 6 | 54 |
4 | 13 | 1300.20 | 20 | 14.80 | 2138 | 633 | 3.58 / 206.02 | 6 | 65 |
5 | 13 | 781.44 | 20 | 14.92 | 1427 | 426 | 4.00 / 206.45 | 6 | 73 |
6 | 13 | 137.44 | 20 | 15.12 | 527 | 159 | 4.16 / 206.61 | 6 | 69 |
7 | 13 | 29.08 | 20 | 15.14 | 376 | 114 | 4.27 / 206.72 | 6 | 66 |
8 | 8 | 0.04 | 240 | 15.09 | 325 | 1177 | 5.45 / 207.90 | 6 | 140 |
Average= | 11.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 36 | 15.10 | 452 | 246 | 0.25 / 197.14 | 6 | 15 |
2 | 7 | 2013.24 | 40 | 14.73 | 3109 | 1832 | 2.08 / 198.98 | 15 | 50 |
3 | 13 | 1919.40 | 20 | 14.72 | 2980 | 877 | 2.95 / 199.85 | 6 | 57 |
4 | 13 | 1403.00 | 20 | 14.78 | 2281 | 674 | 3.63 / 200.53 | 6 | 65 |
5 | 13 | 867.88 | 20 | 14.89 | 1539 | 458 | 4.09 / 200.99 | 6 | 69 |
6 | 13 | 218.96 | 20 | 15.09 | 641 | 193 | 4.28 / 201.18 | 6 | 74 |
7 | 13 | 24.32 | 20 | 15.15 | 345 | 105 | 4.39 / 201.28 | 6 | 67 |
8 | 8 | 0.00 | 240 | 15.09 | 321 | 1163 | 5.55 / 202.45 | 6 | 131 |
Average= | 11.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 36 | 15.08 | 465 | 252 | 0.25 / 191.59 | 6 | 15 |
2 | 7 | 2004.04 | 40 | 14.75 | 3079 | 1817 | 2.07 / 193.40 | 15 | 50 |
3 | 13 | 1921.76 | 20 | 14.73 | 2980 | 878 | 2.95 / 194.28 | 6 | 53 |
4 | 13 | 1515.32 | 20 | 14.76 | 2436 | 719 | 3.67 / 195.00 | 6 | 61 |
5 | 13 | 866.68 | 20 | 14.90 | 1548 | 461 | 4.13 / 195.46 | 6 | 70 |
6 | 13 | 223.60 | 20 | 15.09 | 647 | 195 | 4.32 / 195.66 | 6 | 73 |
7 | 13 | 25.72 | 20 | 15.15 | 346 | 105 | 4.43 / 195.76 | 6 | 65 |
8 | 8 | -0.04 | 240 | 15.10 | 314 | 1138 | 5.57 / 196.90 | 6 | 134 |
Average= | 12.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 36 | 15.10 | 458 | 249 | 0.25 / 185.94 | 6 | 15 |
2 | 7 | 2011.04 | 40 | 14.74 | 3085 | 1819 | 2.07 / 187.76 | 15 | 50 |
3 | 13 | 1914.80 | 20 | 14.73 | 2981 | 878 | 2.95 / 188.64 | 6 | 53 |
4 | 13 | 1479.28 | 20 | 14.76 | 2399 | 708 | 3.65 / 189.34 | 6 | 63 |
5 | 13 | 839.16 | 20 | 14.90 | 1519 | 453 | 4.11 / 189.80 | 6 | 71 |
6 | 13 | 290.28 | 20 | 15.06 | 773 | 233 | 4.34 / 190.03 | 6 | 76 |
7 | 13 | 34.16 | 20 | 15.14 | 384 | 116 | 4.46 / 190.15 | 6 | 69 |
8 | 8 | -0.08 | 240 | 15.09 | 328 | 1188 | 5.64 / 191.33 | 6 | 132 |
Average= | 12.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 36 | 15.10 | 449 | 244 | 0.24 / 180.35 | 6 | 14 |
2 | 7 | 2007.32 | 41 | 14.73 | 3110 | 1878 | 2.12 / 182.23 | 14 | 51 |
3 | 13 | 1913.40 | 20 | 14.73 | 2971 | 875 | 3.00 / 183.10 | 6 | 54 |
4 | 13 | 1392.24 | 20 | 14.79 | 2265 | 670 | 3.67 / 183.77 | 6 | 64 |
5 | 13 | 951.08 | 20 | 14.88 | 1663 | 495 | 4.16 / 184.27 | 6 | 71 |
6 | 13 | 176.64 | 20 | 15.12 | 577 | 174 | 4.34 / 184.44 | 6 | 71 |
7 | 13 | 37.12 | 20 | 15.15 | 365 | 111 | 4.45 / 184.55 | 6 | 67 |
8 | 8 | -0.04 | 238 | 15.10 | 316 | 1136 | 5.58 / 185.69 | 6 | 135 |
Average= | 13.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 36 | 15.11 | 442 | 240 | 0.24 / 174.62 | 6 | 15 |
2 | 7 | 2012.60 | 40 | 14.75 | 3094 | 1825 | 2.07 / 176.45 | 15 | 49 |
3 | 13 | 1924.80 | 20 | 14.73 | 2993 | 882 | 2.95 / 177.33 | 6 | 56 |
4 | 13 | 1722.72 | 20 | 14.71 | 2708 | 797 | 3.74 / 178.12 | 6 | 60 |
5 | 13 | 825.64 | 20 | 14.93 | 1482 | 443 | 4.19 / 178.57 | 6 | 70 |
6 | 13 | 385.76 | 20 | 15.04 | 890 | 268 | 4.45 / 178.83 | 6 | 77 |
7 | 13 | 33.48 | 20 | 15.15 | 370 | 112 | 4.57 / 178.95 | 6 | 65 |
8 | 8 | -0.04 | 240 | 15.10 | 320 | 1160 | 5.73 / 180.11 | 6 | 136 |
Average= | 13.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 36 | 15.10 | 443 | 241 | 0.24 / 169.06 | 6 | 15 |
2 | 7 | 2013.52 | 40 | 14.75 | 3091 | 1824 | 2.06 / 170.88 | 15 | 50 |
3 | 13 | 1915.52 | 20 | 14.75 | 2969 | 876 | 2.94 / 171.76 | 6 | 56 |
4 | 13 | 1391.72 | 20 | 14.81 | 2253 | 667 | 3.61 / 172.43 | 6 | 64 |
5 | 13 | 859.08 | 20 | 14.92 | 1535 | 458 | 4.07 / 172.88 | 6 | 71 |
6 | 13 | 317.68 | 20 | 15.07 | 789 | 238 | 4.30 / 173.12 | 6 | 75 |
7 | 13 | 38.88 | 20 | 15.16 | 366 | 111 | 4.41 / 173.23 | 6 | 68 |
8 | 8 | -0.16 | 238 | 15.11 | 319 | 1147 | 5.56 / 174.38 | 6 | 131 |
Average= | 14.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 36 | 15.11 | 468 | 255 | 0.25 / 163.40 | 6 | 14 |
2 | 7 | 2006.80 | 40 | 14.76 | 3080 | 1818 | 2.07 / 165.22 | 14 | 49 |
3 | 13 | 1926.20 | 20 | 14.74 | 2987 | 881 | 2.95 / 166.10 | 6 | 54 |
4 | 13 | 1523.00 | 20 | 14.77 | 2433 | 719 | 3.67 / 166.82 | 6 | 62 |
5 | 13 | 871.64 | 20 | 14.92 | 1555 | 464 | 4.14 / 167.28 | 6 | 70 |
6 | 13 | 324.08 | 20 | 15.07 | 802 | 242 | 4.38 / 167.52 | 6 | 75 |
7 | 13 | 37.16 | 20 | 15.16 | 380 | 115 | 4.49 / 167.64 | 6 | 67 |
8 | 8 | -0.04 | 242 | 15.11 | 323 | 1181 | 5.67 / 168.82 | 6 | 136 |
Average= | 15.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 36 | 15.11 | 462 | 251 | 0.25 / 157.80 | 6 | 16 |
2 | 7 | 2005.16 | 40 | 14.76 | 3094 | 1827 | 2.08 / 159.63 | 16 | 50 |
3 | 13 | 1916.40 | 20 | 14.75 | 2976 | 878 | 2.96 / 160.51 | 6 | 56 |
4 | 13 | 1392.04 | 20 | 14.82 | 2265 | 671 | 3.63 / 161.18 | 6 | 63 |
5 | 13 | 961.24 | 20 | 14.89 | 1680 | 500 | 4.13 / 161.68 | 6 | 70 |
6 | 13 | 186.24 | 20 | 15.13 | 589 | 178 | 4.31 / 161.86 | 6 | 70 |
7 | 13 | 35.12 | 20 | 15.17 | 360 | 109 | 4.42 / 161.97 | 6 | 66 |
8 | 8 | 0.00 | 240 | 15.12 | 324 | 1176 | 5.59 / 163.14 | 6 | 135 |
Average= | 16.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 36 | 15.12 | 461 | 251 | 0.25 / 152.17 | 6 | 16 |
2 | 7 | 2011.16 | 40 | 14.76 | 3091 | 1825 | 2.08 / 154.00 | 16 | 49 |
3 | 13 | 1915.36 | 20 | 14.75 | 2968 | 876 | 2.95 / 154.87 | 6 | 56 |
4 | 13 | 1501.00 | 20 | 14.79 | 2408 | 712 | 3.66 / 155.59 | 6 | 61 |
5 | 13 | 944.84 | 20 | 14.90 | 1648 | 491 | 4.15 / 156.08 | 6 | 69 |
6 | 13 | 182.00 | 20 | 15.13 | 586 | 177 | 4.33 / 156.26 | 6 | 73 |
7 | 13 | 32.56 | 20 | 15.17 | 377 | 114 | 4.45 / 156.37 | 6 | 68 |
8 | 8 | -0.08 | 240 | 15.12 | 326 | 1183 | 5.63 / 157.55 | 6 | 140 |
Average= | 17.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 36 | 15.11 | 463 | 252 | 0.25 / 146.48 | 6 | 17 |
2 | 7 | 2015.12 | 40 | 14.76 | 3107 | 1834 | 2.09 / 148.32 | 33 | 50 |
3 | 13 | 1925.12 | 20 | 14.76 | 2968 | 876 | 2.96 / 149.19 | 6 | 54 |
4 | 13 | 1406.48 | 20 | 14.81 | 2298 | 681 | 3.64 / 149.87 | 6 | 64 |
5 | 13 | 971.40 | 20 | 14.90 | 1708 | 509 | 4.15 / 150.38 | 6 | 70 |
6 | 13 | 298.36 | 20 | 15.09 | 779 | 235 | 4.39 / 150.62 | 6 | 76 |
7 | 13 | 18.40 | 20 | 15.18 | 361 | 110 | 4.50 / 150.73 | 6 | 66 |
8 | 8 | -0.12 | 240 | 15.12 | 330 | 1198 | 5.69 / 151.92 | 6 | 133 |
Average= | 18.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 36 | 15.11 | 456 | 248 | 0.25 / 140.93 | 6 | 18 |
2 | 7 | 2005.96 | 40 | 14.76 | 3097 | 1828 | 2.08 / 142.76 | 18 | 49 |
3 | 13 | 1915.12 | 20 | 14.76 | 2967 | 876 | 2.95 / 143.64 | 6 | 53 |
4 | 13 | 1390.36 | 20 | 14.83 | 2266 | 672 | 3.62 / 144.31 | 6 | 62 |
5 | 13 | 854.76 | 20 | 14.93 | 1543 | 461 | 4.09 / 144.77 | 6 | 70 |
6 | 13 | 198.16 | 20 | 15.13 | 619 | 187 | 4.27 / 144.96 | 6 | 72 |
7 | 13 | 15.28 | 20 | 15.18 | 351 | 107 | 4.38 / 145.06 | 6 | 66 |
8 | 8 | 0.04 | 235 | 15.12 | 328 | 1165 | 5.54 / 146.23 | 6 | 133 |
Average= | 20.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 36 | 15.12 | 471 | 256 | 0.26 / 135.37 | 6 | 19 |
2 | 7 | 2012.40 | 40 | 14.76 | 3109 | 1836 | 2.09 / 137.21 | 18 | 50 |
3 | 13 | 1913.52 | 20 | 14.76 | 2973 | 878 | 2.97 / 138.09 | 6 | 55 |
4 | 13 | 1389.04 | 20 | 14.83 | 2257 | 669 | 3.64 / 138.76 | 6 | 64 |
5 | 13 | 861.80 | 20 | 14.94 | 1533 | 458 | 4.10 / 139.21 | 6 | 69 |
6 | 13 | 191.92 | 20 | 15.14 | 616 | 187 | 4.28 / 139.40 | 6 | 72 |
7 | 8 | 0.00 | 255 | 15.13 | 333 | 1285 | 5.57 / 140.68 | 6 | 133 |
Average= | 23.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 36 | 15.12 | 463 | 252 | 0.25 / 129.85 | 6 | 20 |
2 | 7 | 2006.04 | 40 | 14.78 | 3083 | 1823 | 2.07 / 131.68 | 20 | 50 |
3 | 13 | 1919.60 | 20 | 14.77 | 2974 | 879 | 2.95 / 132.55 | 6 | 54 |
4 | 13 | 1391.08 | 20 | 14.83 | 2263 | 671 | 3.62 / 133.23 | 6 | 63 |
5 | 13 | 861.36 | 20 | 14.95 | 1543 | 461 | 4.09 / 133.69 | 6 | 71 |
6 | 13 | 105.80 | 20 | 15.18 | 473 | 144 | 4.23 / 133.83 | 6 | 68 |
7 | 13 | 18.60 | 20 | 15.20 | 340 | 103 | 4.33 / 133.93 | 6 | 66 |
8 | 8 | -0.08 | 238 | 15.14 | 328 | 1182 | 5.51 / 135.12 | 6 | 134 |
Average= | 27.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 36 | 15.13 | 459 | 250 | 0.25 / 124.23 | 6 | 18 |
2 | 7 | 2011.84 | 40 | 14.78 | 3089 | 1826 | 2.08 / 126.06 | 18 | 48 |
3 | 13 | 1916.28 | 20 | 14.77 | 2964 | 876 | 2.95 / 126.93 | 6 | 54 |
4 | 13 | 1489.00 | 20 | 14.81 | 2389 | 708 | 3.66 / 127.64 | 6 | 62 |
5 | 13 | 931.68 | 20 | 14.93 | 1639 | 489 | 4.15 / 128.13 | 6 | 70 |
6 | 13 | 152.16 | 20 | 15.15 | 561 | 170 | 4.32 / 128.30 | 6 | 73 |
7 | 8 | 0.00 | 257 | 15.14 | 334 | 1300 | 5.62 / 129.60 | 6 | 130 |
Average= | 32.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 36 | 15.13 | 466 | 254 | 0.25 / 118.68 | 6 | 20 |
2 | 7 | 2010.76 | 40 | 14.77 | 3103 | 1833 | 2.09 / 120.51 | 20 | 50 |
3 | 13 | 1917.72 | 20 | 14.77 | 2974 | 879 | 2.97 / 121.39 | 6 | 53 |
4 | 13 | 1385.84 | 20 | 14.84 | 2248 | 667 | 3.63 / 122.05 | 6 | 64 |
5 | 13 | 845.12 | 20 | 14.96 | 1513 | 453 | 4.09 / 122.51 | 6 | 70 |
6 | 13 | 178.08 | 20 | 15.15 | 580 | 176 | 4.26 / 122.68 | 6 | 72 |
7 | 13 | 13.44 | 20 | 15.20 | 352 | 107 | 4.37 / 122.79 | 6 | 67 |
8 | 8 | -0.08 | 238 | 15.14 | 331 | 1193 | 5.56 / 123.98 | 6 | 135 |
Average= | 41.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 36 | 15.14 | 458 | 250 | 0.25 / 113.02 | 6 | 16 |
2 | 7 | 2012.36 | 40 | 14.79 | 3074 | 1819 | 2.07 / 114.84 | 16 | 49 |
3 | 13 | 1917.56 | 20 | 14.78 | 2977 | 880 | 2.95 / 115.72 | 6 | 55 |
4 | 13 | 1313.80 | 20 | 14.87 | 2146 | 638 | 3.59 / 116.36 | 6 | 65 |
5 | 13 | 990.44 | 20 | 14.92 | 1709 | 510 | 4.10 / 116.87 | 6 | 68 |
6 | 13 | 314.80 | 20 | 15.11 | 790 | 239 | 4.34 / 117.11 | 6 | 77 |
7 | 13 | 18.76 | 20 | 15.19 | 360 | 109 | 4.44 / 117.22 | 6 | 69 |
8 | 8 | -0.08 | 240 | 15.14 | 332 | 1206 | 5.65 / 118.42 | 6 | 137 |
Average= | 59.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 35 | 15.14 | 465 | 246 | 0.25 / 107.38 | 6 | 17 |
2 | 7 | 2012.96 | 40 | 14.79 | 3083 | 1824 | 2.07 / 109.21 | 17 | 49 |
3 | 13 | 1929.04 | 20 | 14.78 | 2987 | 883 | 2.95 / 110.09 | 6 | 54 |
4 | 13 | 1504.60 | 20 | 14.83 | 2423 | 719 | 3.67 / 110.81 | 6 | 62 |
5 | 13 | 855.00 | 20 | 14.96 | 1553 | 465 | 4.14 / 111.27 | 6 | 71 |
6 | 13 | 196.60 | 20 | 15.15 | 631 | 191 | 4.33 / 111.46 | 6 | 73 |
7 | 13 | 17.72 | 20 | 15.20 | 362 | 110 | 4.44 / 111.57 | 6 | 67 |
8 | 8 | -0.04 | 238 | 15.15 | 332 | 1197 | 5.63 / 112.77 | 6 | 133 |
Average= | 112.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 36 | 15.16 | 452 | 247 | 0.25 / 101.77 | 6 | 14 |
2 | 7 | 2014.20 | 40 | 14.80 | 3088 | 1828 | 2.07 / 103.59 | 14 | 49 |
3 | 13 | 1924.08 | 20 | 14.79 | 2974 | 880 | 2.95 / 104.47 | 6 | 52 |
4 | 13 | 1508.32 | 20 | 14.83 | 2414 | 716 | 3.67 / 105.19 | 6 | 62 |
5 | 13 | 856.44 | 20 | 14.97 | 1531 | 458 | 4.13 / 105.65 | 6 | 71 |
6 | 13 | 207.20 | 20 | 15.16 | 626 | 190 | 4.32 / 105.84 | 6 | 75 |
7 | 13 | 23.36 | 20 | 15.21 | 360 | 110 | 4.43 / 105.95 | 6 | 67 |
8 | 8 | -0.12 | 238 | 15.15 | 330 | 1190 | 5.62 / 107.14 | 6 | 132 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 36 | 15.16 | 451 | 246 | 0.25 / 96.18 | 6 | 14 |
2 | 7 | 2003.72 | 40 | 14.80 | 3095 | 1832 | 2.08 / 98.02 | 14 | 50 |
3 | 13 | 1912.20 | 20 | 14.79 | 2965 | 877 | 2.96 / 98.89 | 6 | 53 |
4 | 13 | 1377.64 | 20 | 14.87 | 2239 | 666 | 3.62 / 99.56 | 6 | 66 |
5 | 13 | 839.56 | 20 | 14.97 | 1519 | 455 | 4.08 / 100.01 | 6 | 70 |
6 | 13 | 193.16 | 20 | 15.16 | 624 | 189 | 4.27 / 100.20 | 6 | 74 |
7 | 13 | 19.44 | 20 | 15.21 | 364 | 111 | 4.38 / 100.31 | 6 | 67 |
8 | 8 | 0.04 | 240 | 15.16 | 331 | 1204 | 5.58 / 101.52 | 6 | 133 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 36 | 15.16 | 445 | 243 | 0.24 / 90.71 | 6 | 12 |
2 | 7 | 2006.72 | 41 | 14.80 | 3095 | 1878 | 2.12 / 92.59 | 12 | 50 |
3 | 13 | 1918.40 | 20 | 14.79 | 2967 | 878 | 3.00 / 93.47 | 6 | 50 |
4 | 13 | 1289.48 | 20 | 14.89 | 2123 | 632 | 3.63 / 94.10 | 6 | 66 |
5 | 13 | 773.52 | 20 | 15.00 | 1417 | 425 | 4.06 / 94.53 | 6 | 72 |
6 | 13 | 63.16 | 20 | 15.22 | 408 | 124 | 4.18 / 94.65 | 6 | 67 |
7 | 13 | 17.52 | 20 | 15.22 | 334 | 102 | 4.28 / 94.75 | 6 | 65 |
8 | 8 | -0.08 | 240 | 15.17 | 326 | 1187 | 5.47 / 95.94 | 6 | 144 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 36 | 15.17 | 459 | 251 | 0.25 / 85.09 | 6 | 13 |
2 | 7 | 2004.20 | 40 | 14.81 | 3085 | 1828 | 2.08 / 86.91 | 13 | 51 |
3 | 13 | 1917.64 | 20 | 14.80 | 2977 | 881 | 2.96 / 87.79 | 6 | 53 |
4 | 13 | 1409.84 | 20 | 14.87 | 2285 | 680 | 3.64 / 88.47 | 6 | 63 |
5 | 13 | 969.56 | 20 | 14.94 | 1695 | 506 | 4.15 / 88.98 | 6 | 70 |
6 | 13 | 192.48 | 20 | 15.17 | 620 | 188 | 4.33 / 89.17 | 6 | 73 |
7 | 13 | 18.84 | 20 | 15.22 | 362 | 110 | 4.44 / 89.28 | 6 | 67 |
8 | 8 | 0.04 | 240 | 15.17 | 327 | 1191 | 5.63 / 90.47 | 6 | 138 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 35 | 15.17 | 458 | 243 | 0.24 / 79.44 | 6 | 13 |
2 | 7 | 2006.16 | 40 | 14.81 | 3094 | 1833 | 2.08 / 81.27 | 13 | 48 |
3 | 13 | 1920.56 | 20 | 14.81 | 2968 | 879 | 2.96 / 82.15 | 6 | 55 |
4 | 13 | 1499.40 | 20 | 14.85 | 2393 | 711 | 3.67 / 82.86 | 6 | 61 |
5 | 13 | 855.44 | 20 | 14.98 | 1549 | 464 | 4.13 / 83.32 | 6 | 71 |
6 | 13 | 209.32 | 20 | 15.17 | 644 | 195 | 4.33 / 83.52 | 6 | 72 |
7 | 13 | 24.04 | 20 | 15.22 | 367 | 112 | 4.44 / 83.63 | 6 | 65 |
8 | 8 | -0.08 | 242 | 15.17 | 328 | 1204 | 5.64 / 84.84 | 6 | 142 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 35 | 15.18 | 450 | 239 | 0.24 / 73.83 | 6 | 12 |
2 | 7 | 2007.36 | 40 | 14.81 | 3095 | 1833 | 2.07 / 75.66 | 12 | 49 |
3 | 13 | 1923.40 | 20 | 14.81 | 2976 | 881 | 2.95 / 76.54 | 6 | 54 |
4 | 13 | 1465.64 | 20 | 14.86 | 2352 | 699 | 3.65 / 77.24 | 6 | 64 |
5 | 13 | 810.00 | 20 | 15.00 | 1470 | 441 | 4.09 / 77.68 | 6 | 70 |
6 | 13 | 262.88 | 20 | 15.15 | 705 | 214 | 4.31 / 77.90 | 6 | 75 |
7 | 13 | 29.24 | 20 | 15.22 | 358 | 109 | 4.42 / 78.01 | 6 | 69 |
8 | 8 | 0.04 | 240 | 15.17 | 326 | 1187 | 5.60 / 79.19 | 6 | 132 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 35 | 15.18 | 462 | 245 | 0.25 / 68.21 | 6 | 11 |
2 | 7 | 2011.08 | 41 | 14.81 | 3081 | 1871 | 2.12 / 70.08 | 11 | 49 |
3 | 13 | 1916.64 | 20 | 14.81 | 2960 | 877 | 2.99 / 70.96 | 6 | 54 |
4 | 13 | 1479.68 | 20 | 14.86 | 2371 | 705 | 3.70 / 71.67 | 6 | 62 |
5 | 13 | 922.28 | 20 | 14.97 | 1613 | 483 | 4.18 / 72.15 | 6 | 70 |
6 | 13 | 153.96 | 20 | 15.20 | 543 | 165 | 4.35 / 72.31 | 6 | 72 |
7 | 13 | 33.40 | 20 | 15.23 | 362 | 110 | 4.46 / 72.42 | 6 | 67 |
8 | 8 | 0.00 | 240 | 15.18 | 320 | 1166 | 5.62 / 73.59 | 6 | 131 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 35 | 15.19 | 452 | 240 | 0.24 / 62.61 | 6 | 12 |
2 | 7 | 2010.72 | 41 | 14.82 | 3092 | 1879 | 2.12 / 64.49 | 12 | 49 |
3 | 13 | 1814.64 | 20 | 14.83 | 2841 | 843 | 2.96 / 65.33 | 6 | 55 |
4 | 13 | 1385.04 | 20 | 14.89 | 2246 | 669 | 3.63 / 66.00 | 6 | 64 |
5 | 13 | 958.60 | 20 | 14.96 | 1667 | 499 | 4.13 / 66.50 | 6 | 71 |
6 | 13 | 186.92 | 20 | 15.19 | 594 | 180 | 4.31 / 66.68 | 6 | 74 |
7 | 13 | 22.52 | 20 | 15.24 | 343 | 105 | 4.41 / 66.78 | 6 | 65 |
8 | 8 | -0.04 | 240 | 15.18 | 326 | 1188 | 5.60 / 67.97 | 6 | 134 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 35 | 15.18 | 460 | 244 | 0.24 / 57.08 | 6 | 13 |
2 | 7 | 2014.44 | 40 | 14.82 | 3111 | 1844 | 2.09 / 58.92 | 13 | 49 |
3 | 13 | 1920.64 | 20 | 14.81 | 2979 | 882 | 2.97 / 59.80 | 6 | 56 |
4 | 13 | 1487.84 | 20 | 14.86 | 2387 | 709 | 3.68 / 60.51 | 6 | 62 |
5 | 13 | 802.12 | 20 | 15.01 | 1451 | 436 | 4.12 / 60.95 | 6 | 69 |
6 | 13 | 77.16 | 20 | 15.23 | 427 | 130 | 4.25 / 61.08 | 6 | 68 |
7 | 13 | 22.60 | 20 | 15.24 | 360 | 110 | 4.36 / 61.19 | 6 | 65 |
8 | 8 | -0.08 | 238 | 15.19 | 326 | 1179 | 5.53 / 62.37 | 6 | 132 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 35 | 15.17 | 461 | 245 | 0.24 / 51.65 | 6 | 12 |
2 | 7 | 2011.60 | 40 | 14.82 | 3092 | 1833 | 2.08 / 53.49 | 12 | 49 |
3 | 13 | 1818.92 | 20 | 14.84 | 2854 | 847 | 2.92 / 54.33 | 6 | 56 |
4 | 13 | 1305.16 | 20 | 14.91 | 2144 | 639 | 3.56 / 54.97 | 6 | 64 |
5 | 13 | 769.04 | 20 | 15.02 | 1422 | 427 | 3.99 / 55.40 | 6 | 71 |
6 | 13 | 68.24 | 20 | 15.23 | 435 | 133 | 4.12 / 55.53 | 6 | 67 |
7 | 13 | 20.72 | 20 | 15.24 | 364 | 111 | 4.23 / 55.64 | 6 | 65 |
8 | 8 | -0.04 | 238 | 15.19 | 329 | 1189 | 5.42 / 56.83 | 6 | 135 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 35 | 15.19 | 451 | 240 | 0.24 / 46.01 | 6 | 11 |
2 | 7 | 2006.36 | 40 | 14.83 | 3092 | 1834 | 2.07 / 47.85 | 11 | 49 |
3 | 13 | 1922.60 | 20 | 14.83 | 2983 | 885 | 2.96 / 48.73 | 6 | 55 |
4 | 13 | 1310.28 | 20 | 14.91 | 2156 | 643 | 3.60 / 49.37 | 6 | 64 |
5 | 13 | 1005.92 | 20 | 14.95 | 1743 | 521 | 4.12 / 49.89 | 6 | 68 |
6 | 13 | 215.64 | 20 | 15.18 | 655 | 199 | 4.32 / 50.09 | 6 | 74 |
7 | 13 | 25.56 | 20 | 15.23 | 370 | 113 | 4.43 / 50.21 | 6 | 67 |
8 | 8 | -0.16 | 240 | 15.18 | 330 | 1202 | 5.64 / 51.41 | 6 | 131 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 35 | 15.19 | 458 | 243 | 0.24 / 40.48 | 6 | 12 |
2 | 7 | 2008.48 | 40 | 14.84 | 3088 | 1833 | 2.08 / 42.32 | 10 | 50 |
3 | 13 | 1909.88 | 20 | 14.84 | 2961 | 879 | 2.96 / 43.20 | 6 | 54 |
4 | 13 | 1483.00 | 20 | 14.88 | 2379 | 708 | 3.66 / 43.90 | 6 | 63 |
5 | 13 | 815.64 | 20 | 15.02 | 1473 | 442 | 4.11 / 44.35 | 6 | 70 |
6 | 13 | 85.96 | 20 | 15.24 | 442 | 135 | 4.24 / 44.48 | 6 | 67 |
7 | 13 | 24.68 | 20 | 15.25 | 343 | 105 | 4.35 / 44.59 | 6 | 65 |
8 | 8 | 0.00 | 240 | 15.19 | 325 | 1185 | 5.53 / 45.77 | 6 | 135 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 34 | 15.20 | 439 | 227 | 0.23 / 34.79 | 6 | 11 |
2 | 3 | 1018.72 | 1 | 15.24 | 1783 | 27 | 0.25 / 34.82 | 6 | 21 |
3 | 7 | 2010.96 | 40 | 14.84 | 3094 | 1837 | 2.09 / 36.65 | 21 | 50 |
4 | 13 | 1913.04 | 20 | 14.84 | 2976 | 883 | 2.97 / 37.54 | 6 | 53 |
5 | 13 | 1382.08 | 20 | 14.90 | 2248 | 670 | 3.64 / 38.21 | 6 | 63 |
6 | 13 | 944.56 | 20 | 14.98 | 1646 | 493 | 4.14 / 38.70 | 6 | 70 |
7 | 13 | 271.28 | 20 | 15.17 | 722 | 219 | 4.36 / 38.92 | 6 | 75 |
8 | 13 | 33.88 | 20 | 15.24 | 382 | 116 | 4.47 / 39.04 | 6 | 68 |
9 | 8 | -0.08 | 240 | 15.18 | 331 | 1206 | 5.68 / 40.24 | 6 | 135 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 34 | 15.19 | 447 | 231 | 0.23 / 29.45 | 6 | 12 |
2 | 7 | 2012.24 | 40 | 14.84 | 3094 | 1837 | 2.07 / 31.29 | 7 | 50 |
3 | 13 | 1916.28 | 20 | 14.84 | 2971 | 882 | 2.95 / 32.17 | 6 | 53 |
4 | 13 | 1187.08 | 20 | 14.95 | 1980 | 592 | 3.54 / 32.76 | 6 | 65 |
5 | 13 | 780.36 | 20 | 15.03 | 1425 | 428 | 3.97 / 33.19 | 6 | 71 |
6 | 13 | 75.44 | 20 | 15.24 | 424 | 129 | 4.10 / 33.32 | 6 | 66 |
7 | 13 | 42.08 | 20 | 15.24 | 371 | 113 | 4.21 / 33.43 | 6 | 65 |
8 | 8 | 0.00 | 242 | 15.20 | 308 | 1133 | 5.34 / 34.56 | 6 | 143 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 33 | 15.19 | 450 | 226 | 0.23 / 24.08 | 6 | 13 |
2 | 3 | 1044.60 | 1 | 15.20 | 1800 | 27 | 0.25 / 24.11 | 6 | 40 |
3 | 7 | 2012.88 | 40 | 14.85 | 3096 | 1839 | 2.09 / 25.95 | 40 | 50 |
4 | 13 | 1914.08 | 20 | 14.84 | 2962 | 879 | 2.97 / 26.83 | 6 | 54 |
5 | 13 | 1287.64 | 20 | 14.93 | 2112 | 631 | 3.60 / 27.46 | 6 | 64 |
6 | 13 | 764.28 | 20 | 15.03 | 1400 | 421 | 4.02 / 27.88 | 6 | 71 |
7 | 13 | 112.96 | 20 | 15.23 | 480 | 146 | 4.17 / 28.02 | 6 | 69 |
8 | 13 | 31.48 | 20 | 15.25 | 353 | 108 | 4.28 / 28.13 | 6 | 63 |
9 | 8 | 0.04 | 240 | 15.20 | 298 | 1087 | 5.36 / 29.22 | 6 | 135 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 31 | 15.20 | 428 | 202 | 0.20 / 18.65 | 6 | 12 |
2 | 10 | 1015.52 | 3 | 15.16 | 1766 | 80 | 0.28 / 18.73 | 6 | 48 |
3 | 7 | 2006.08 | 41 | 14.86 | 3091 | 1883 | 2.17 / 20.61 | 48 | 48 |
4 | 13 | 1922.52 | 20 | 14.85 | 2976 | 884 | 3.05 / 21.49 | 6 | 53 |
5 | 13 | 1197.36 | 20 | 14.96 | 2006 | 600 | 3.65 / 22.09 | 6 | 66 |
6 | 13 | 687.04 | 20 | 15.05 | 1307 | 393 | 4.04 / 22.49 | 6 | 72 |
7 | 13 | 77.88 | 20 | 15.24 | 433 | 132 | 4.17 / 22.62 | 6 | 67 |
8 | 13 | 19.40 | 20 | 15.25 | 347 | 106 | 4.28 / 22.73 | 6 | 64 |
9 | 8 | 0.12 | 238 | 15.20 | 312 | 1129 | 5.41 / 23.85 | 6 | 135 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 33 | 15.19 | 418 | 210 | 0.21 / 14.05 | 6 | 13 |
2 | 7 | 1505.68 | 40 | 15.03 | 2406 | 1446 | 1.66 / 15.50 | 13 | 56 |
3 | 13 | 1433.16 | 20 | 15.01 | 2309 | 693 | 2.35 / 16.19 | 6 | 58 |
4 | 13 | 1129.44 | 20 | 15.02 | 1911 | 574 | 2.92 / 16.77 | 6 | 65 |
5 | 13 | 597.60 | 20 | 15.11 | 1188 | 359 | 3.28 / 17.13 | 6 | 73 |
6 | 13 | 47.00 | 20 | 15.26 | 388 | 118 | 3.40 / 17.25 | 6 | 65 |
7 | 13 | 14.88 | 20 | 15.27 | 336 | 103 | 3.50 / 17.35 | 6 | 65 |
8 | 8 | 0.00 | 238 | 15.21 | 303 | 1097 | 4.60 / 18.45 | 6 | 142 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 32 | 15.19 | 432 | 210 | 0.21 / 9.42 | 6 | 13 |
2 | 3 | 1027.48 | 1 | 15.22 | 1803 | 27 | 0.24 / 9.44 | 6 | 16 |
3 | 7 | 1517.80 | 41 | 15.01 | 2431 | 1496 | 1.73 / 10.94 | 16 | 55 |
4 | 13 | 1440.08 | 20 | 15.00 | 2325 | 697 | 2.43 / 11.64 | 6 | 59 |
5 | 13 | 1149.28 | 20 | 15.01 | 1939 | 582 | 3.01 / 12.22 | 6 | 65 |
6 | 13 | 512.68 | 20 | 15.13 | 1068 | 323 | 3.34 / 12.54 | 6 | 73 |
7 | 13 | 43.24 | 20 | 15.26 | 383 | 117 | 3.45 / 12.66 | 6 | 67 |
8 | 13 | 12.96 | 20 | 15.26 | 338 | 103 | 3.56 / 12.76 | 6 | 65 |
9 | 8 | -0.04 | 235 | 15.21 | 303 | 1083 | 4.64 / 13.85 | 6 | 136 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 31 | 15.22 | 437 | 206 | 0.21 / 4.71 | 6 | 13 |
2 | 3 | 1052.84 | 1 | 15.21 | 1823 | 28 | 0.23 / 4.74 | 6 | 44 |
3 | 7 | 1506.20 | 40 | 15.03 | 2388 | 1436 | 1.67 / 6.17 | 44 | 55 |
4 | 13 | 1434.96 | 20 | 15.01 | 2295 | 689 | 2.36 / 6.86 | 6 | 58 |
5 | 13 | 1233.48 | 20 | 15.00 | 2015 | 604 | 2.96 / 7.46 | 6 | 62 |
6 | 13 | 791.92 | 20 | 15.06 | 1416 | 426 | 3.39 / 7.89 | 6 | 68 |
7 | 13 | 51.16 | 20 | 15.26 | 380 | 116 | 3.51 / 8.01 | 6 | 65 |
8 | 8 | 0.08 | 261 | 15.21 | 302 | 1199 | 4.70 / 9.21 | 6 | 147 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 31 | 15.47 | 412 | 198 | 0.20 / 1.78 | 6 | 11 |
2 | 3 | 1041.72 | 1 | 15.26 | 1820 | 28 | 0.23 / 1.81 | 6 | 39 |
3 | 7 | 1022.92 | 40 | 15.14 | 1702 | 1031 | 1.26 / 2.84 | 39 | 59 |
4 | 13 | 600.76 | 20 | 15.20 | 1165 | 354 | 1.61 / 3.19 | 6 | 67 |
5 | 13 | 39.76 | 20 | 15.32 | 380 | 116 | 1.73 / 3.31 | 6 | 66 |
6 | 8 | 0.08 | 257 | 15.27 | 304 | 1193 | 2.92 / 4.50 | 6 | 131 |
Average= | 2.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 62.68 | 30 | 15.64 | 328 | 154 | 0.15 / 0.15 | 6 | 13 |
2 | 7 | 73.16 | 40 | 15.62 | 354 | 221 | 0.38 / 0.38 | 13 | 17 |
3 | 13 | 51.56 | 20 | 15.61 | 327 | 102 | 0.48 / 0.48 | 6 | 20 |
4 | 13 | 30.48 | 20 | 15.60 | 300 | 94 | 0.57 / 0.57 | 6 | 22 |
5 | 8 | 0.04 | 255 | 15.55 | 255 | 1011 | 1.58 / 1.58 | 6 | -99 |
Average= | 1.58 (KJ/cycle) |